Loading...
HomeMy WebLinkAboutPermit M2000-252 - SOUTHCENTER MALL - NOR SUSHI AND GRILLM2000 -252 Nori Sushi & Grill 896 Southcenter Mall • City of Tukwila (206) 431.3670 Community Development / Public Works • b300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M2000 -252 Type: B -MECH Category: NRES Address: 896 SOUTHCENTER MALL Location: Parcel *: 262304 -9004 Contractor License No: NORTHS *01681 INSTALL CLASS I HOOD. aTrIT Permit Center MECHANICAL PERMIT TENANT NORI SUSHI AND GRILL 896 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN:, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 _ CONTACT DON ANGELINE Phone: 253 -606 -0525 9318 SR 162, PUYALLUP, WA 98374 CONTRACTOR NORTHWEST STAINLESS 14528 128th ST E, PUYALLUP WA 98374 ***************,*************************** * * ** * * * * * * * * * * * * * * * * * * * * * ** * * ** Permit Description: UMC Edition: 1997 Valuation: Total Permit Fee: �.. 12. (0-- horized Signature Date Status: ISSUED Issued: 12/06/2000 Expires: 06/04/2001 6,500.00 51.75 *** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Slgneture:A .__4_ . Date: + Print Name: .= _,..,L ,. �t t? Title: amd/L t-� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 896 SOUTHCENTER MALL Suite: Tenant: NORI SUSHI AND GRILL Type: B-MECH Parc41 #: 262304-9004 CITY OF TUKWILA Permit No M2000-252 Status: ISSUED Applied: 11/09/2000 Issued: 12/06/2000 A**********k*A*k***********k***A***k****A****Akkhk****k***********khk4***k* Permit Conditions: 1, Readily accessible access to roof mounted equipment is required, 2. Plumbing permits shall be obtained through the Seattle-King County Department of Public Health, Plumbing will be inspected by that agency, including all gas piping (296-4722). 3. Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248-6630). 4. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 5. All permits, inspection records, and approved plans shell be available at the iob site prior to the start of any con- struction. These documents are to be maintained and avail- able until final inspection approval is granted. 6. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended. Uniform Mechanical Code (1997 Edition). and Washington State Energy Code (1997 Edition). 7. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the iurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid, 8. Manufacturers installation instructions required on site for the building inspectors review, 9. The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 10. Commercial-type food heat-processing equipment from which grease-laden vapors emanate in normal cooking application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when the system is actuated. (UFC 1006) 1i A wet chemical portable fire extinguisher having a minimum rating of 2A:18:C:1( shall be installed within 30 feet of commercial food heat-processing equipment, as measured along an obstructed path of travel. (UFC 1006.2.7). 12. A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #1900. 13. Local U.L. central station supervision is required, (City Ordinance #1900) A 4.. All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained, (City Ordinance . #190(1) (UFC 1001.3) 5. Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have lob site address. name and •Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) j Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 17. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 18. This review limited to speculative tenant space only special fire permits may be necessary.dopending on detailed description of intended use. . 19. Any overlooked Hazardous condition and/or. violation of the .adopted Fire: or Bui ldinq Codes does not imply apprcava1 of such condition or Violation. ;THESE PLANS WERE REVIEWED BY .INSPECTOR 512 IF YOU HAVE ANY OUESTIONS . `PLEASE CALL THE TUKWILA FIRE PJEVENTION BUREAU AT (206)575 -4407. I hereby oertifv that 1 have read these conditions and will comply w i th : them e.s Outlined.' All P r o v i s i o n s of law and orci,i nances govern i na this work will b e corplled with, whether specified hereinfor not, The grertt:l ng o.? this permit does .not presume to g i v e author l tV t v.l o l e to or cancel the provisions-of nnv' other work or local laws roquletln9 construction or the performanoe of work. Project Name/Tenant: Signature Date: ., pip Print name: - V lue of Mechanical Equipment: Fax #: 1ZT ) / s- 3 Address: Site Address : City State/Zip: Tax P c • I a • Atig i ., Property Owner: Phone: ( Street Address: City State/Zip: Fax #: ( Contractor: A/ Le > r S l�(, i ltd .sS Phone: (23 ) 4 .2 ? S Street'Address: Cit State/Zip: Fax #: ( ) Cont t Person: Phone: ( ) Street Address: City State/Zip: Fax It: ( ) BUILDING OWNER OR RUTH • RIZED ENT: Signature Date: ., pip Print name: - Phone: (?A) ec, 6° c al- Fax #: 1ZT ) / s- 3 Address: City / State/Zip: Date applicrefcceo Date applicatio 5- xpires: l Application taken by: (initials) CITY OF T; CWILA Permit Center 6300 Southc:enter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TU RE FILLED OUT BY APPLICANT) Description of work to be done please be specifi9: Current copy of Washington State Department of Labor and industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H•4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than tho owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from ilia property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal, I HEREBY CERTIFY THAT I IMYE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review • Applications for which no permit is issued within 100 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. 11/2/99 'arch prrmis.doc ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location o: each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being Installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Sin lgle Fam ily Resid Heat loss calculations or Form I=1.G. Equipment specifications. Chan nge'nut or replacement of exlstin, mechanical e ul 'ment Narrative of work to be done Includin modification to duct work. Installation of Gies Flre lace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweet= stating ih'ft the chimney Is in safe condition. NOTE: Water heaters and vents are included In the Uniform Mechanical Code — please include any water, heaters or vents being Installed or replaced, 112/99 niscprLdac z 1 O 0 2 w O o O a 8 St :Y * ** * ** ** *s ******************** * ****** *****k * *******k * **** *** 1Y-OF ttfh WLts1 . WI.; r .. ' ' 1Kra ;yfh1 s * * *' * ** * * * ** 4 * * * **** * 24z ** * * * # * * * * * ** ** * * *** ** * * *1 ** 40411.3M1I NUmbe"rt k9.1f0 401 Amounts . :il.la 12rQ6 /0t, L s :L% tfnt Matnod CHECK. Notations 0001 ANOULLNE 1n. t;: mo • .+ac. a *s...,. -.r.w iteN 1; Bldg. M2000-252 rvngs U 'MECN MECHANICAL PERM, f Pirct l tlo t ;62304 -9004 tssAddruuu s 096" 13Qt1 TNCEN TER MALL total Venus 31. 3 : h t a °Fs visamyst 01.,75 lots! ALL Pmts s bL.7b dnlans:ea .V0 * *** *44* *f►14##'* ** '*********** *11t *e****lr*tA'***A66* *1l#th** *fir *** *iY**** 'Nucou .l: UosGr s ut i Fyn 000/345.030 PLAN CHECK — NuNREb 000/J22.100 MECHANICAL NUNRCS a.—.Oft - - a --- — 4..a .a a. a.*1- • 051.2 1,2/08 9710 TOTAL i PERMIT NO.: AA i00045i. MECHANICAL PERMIT APPLICATIONS INSPECTIONS ❑ 00002 Pre•construction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC 00610 Chimney Installation/All Types 00700 Framing 01080 Woodstove ❑ 01090 Smoke Detector Shut Off 01100 Rough -in Mechanical ❑ 01101 Mechanical Equipment/Controls ❑ 01102 Mechanical Pip/Duct tnsul 12 01105 Underground Mech Rough -in 01115 Motor inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System COND1TTO 4S 0001 No changes to plans unless approved by Bldg Div 4,1e 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 MI construetlon to be done in conformance w /approved plans 0002 Plumbing permits shall be obtained through KIng Co 0027, Validity of Permit 0003 Electrical permits obtained through L, & 1 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces "Fuel burning appliances "Appliances, which generate...." "Water heater shall be anchored.... 8 11 TENANT NAME: FEES Permit Tech: Plan Reviewer liret • Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner • to 100,000 BTU (qty) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wall/Floor-mounted Heater (qty) Appliance Vent (qry) Heating/Refrfg/Cooling UniWSystem (qry) Boiler /Compressor to 3 HP /100,000 BTU (qry) to 15 HP /500,000 BTTJ (qry) to 30 HP /1,000,000 BTU (qry) to 30 HP/1,750,000 BTU (qty) over 30 HP/1,750,000 BTU (qry) Mr Handling Unit to 10,000 ctlm (qry) over 10,000 cfrn (qry) Evaporative Cooler (qry) Ventilation Fan (qry) Ventilation System (qry) Hood (qry) Incinerator - Domestic (qry) incinerator — Comm/ind (qry) Other Mechanical Equipment (qty) Other Mechanical Fee (enter SS) Add'I Fees — Work w/o Permit (Y/N) Insp Outside Normal Hours (hrs) Rainspections (hrs) . Miscellaneous Inspections (hrs) Add'1 Plan Review (hrs) s 8 Y i , ��.... ns ecti , r A o r r ` s+ eh C TP : " " '" -- Date aged: 2G ' o / Special instructions: Date wanted: a. Requester: Phone: & 3 ,., cfi 0 MENTS: Receipt No: Date: Date: Inspector '�. $47.00 REINSPECTION FEE REQUIRED Prior to inspection, fee must be paid at 6300 Southcenter Blvd. Suite 100. Cali to schedule reins ' ection. INSPECTION NO INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION J 6300 Southcenter Blvd, #100, Tukwila, WA 98186.___._... 206)431 -367 • Approved per applicable codes. Corrections required prior to approval, "§ ea IF ,., Ty e 4' Insp ction :, WA, , ! ate oiled: 1 26 Special instructions: Date wanted: 2.0 ! �•. , ,,� Requester: /A Phone: 42 - / � A, ' :• INSPECTION RECORD Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 LJ Approved per applicable codes, PERMIT NO. (206)431 -3 Corrections required prior to approval. $47.00 REINSPECTION ° E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, CaII to schedule reins action. Receipt No: Date: 1 g r Ai,.rf' Y Project Name Address o of eg3 14 r j kr4- -4:4 i - 4- .Al+1Y'Ir S1Tn L4f' -JVid •;1J at tir ri 77';; 7'•. - ti City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL PORN : e; #411° Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: permits: 104? 0 Authorized Signature FINAIJAPP . FRM r T 11•01•1 € //ra / Ilan) Permit No l e ; l T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Xeefe, Are Chief Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206 5754404 • Fax (206) 575409 Project: Ay /70 4,5-. 4, ' Type ofIpectio;: z ry., .... /I _ Address: Date call d: Special instructions: Date wante . 11 Phone: ri Approved per applicable codes. El Corrections required prior to approval. COMMENTS! :2-----,4inete.4ek At. .4 OM* INSPECTION RECORD Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. (206)431-3670 $47.00 REINSFECTIO TEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins ection. . • i • Project: OY/ 5OA; Ty.e of Inspection: Address: (4 5 W ce� , fir Mal bat all d: /'1l0/ .... Special instructions: 6 0-1 ?" 1,14 /4"---74) Da t wanted: ,), —_�._ ( a, m. R +u star: ' : Phone: Approved per apptIcab1 ed , COMMENTS: INSPECTION RECORD Retain a copy with permit INSPECt10RNO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 4.� PERMIT NO, (206)431 -3670 Corrections required prior approval. $47,00 REINSPECTIO ' FEE REQUIRED, Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins • action. Project: Type o spectio•: .. Addres , D.te called: Special instructions: . ate wan ed: Request .r: Phone: INSPECTION RECORD Retain a copy with permit INSPtCtION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Corrections required prior to approval. Approved per applicable codes. 0 $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd, Suito 100. CaII to schedule reins action. PERMIT NO. (206)431-3 Project: / c , • fvfy, ._)6/3„,/ .... e of Inspection: - Address:, --.., X16:$ (1 50, D e / (, 0 / Special instructions: X pi clay IP atiouick 0( a r/I vet/ Date w nted: 0/ a.m. .m. pippiter: P one: - 1) - 44, COMMENTS: Date: E3 $47,00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins ection. Receipt No: Date: . INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per appl codes, Corrections required prior to approval. PERMIT NO. (206)431-3670 project: - GY t USat Typ o Insp • etion: ' CrITd Wit( • dress: —D S o * t' t Date cal at: 1Z -x--00 Special instructions: Date wanted' Requeste Ph' '7Cft , Gb — 9 I 05 INSPMCBION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RECORD Retain a ropy with permit (206)431-3670 Approved per applicable codes. Corrections required prior to approval. 7.00 REINSPECTIO 'TAE REQUIRED, Prior to Inspection, fee mutt be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspec Receipt No; Date; Fam EAliiiil PGalliii r i l 61 tt-,.,k.:,:f1.:;:..:,:i, .; r 131.i Pr 131 IM M Iatra J eswort MI s 211 a • 1 l*AI K 1! NIM S OM m pal mail 1, ,t 1,i: i '• � /. • �. • j • t .LM.n Willi 1 1a r fo RErinsrowip el1 OCT.10.2000 11:08AM Fi1'p!MtiatCPe FAStWl'iij+ Commercial Kitchen Grease Duct Pare Protection System Product Dots endosun for MOM combustibles WM" 1000 WO �oa�n� bin � Ma�r'wh.n� CAPTIVE AIRE r * low �IMM no used Aor �Nowarl w�fw�, lire rMM►tt to Mr! mie0 ,M* ttM PIreee MNr Frost ripr. AM ON* to Poe Iln we %lib Its mrooNent or oder kb oasnaclid r�r a�nrr Male t used ki dor I 1.4 shahs **wino dial when It wide end Noah rroallle: Posittlso • LOW bloperslellint klauMt on blanket • NW eliernotlio • Zero Ito oarless*** protection it lhs • WOO" 04MPsot destan t • Pledbla *quints Oilman Mbar • Problsm S OW tar light congested ariii • rn .nWemuvs kitchen wpm nN o whour dud*, F eletarwe o prattles or F�Uo r ti .p►.a unstop tiro nerd wiser and float YL1zb 2S2 S, Physical Import is MO.789 P.1 4 BpwoWloatfon$ FIr lor 10 o" r�►�tw and 000 w18 Moons 11AMIN1t OA NroNsW restW should be Welled In moarde w1 tt* Marian Initiations on the =aerPitifitterretwoaduciil d ,w s ha Mm Ind MMi should be *WPM P IA I M FI~er risiWnop+, r, Paelonn.rtaa A,1'ypioal P11yduI Popertles iM pIIMAoiMr PopkWrops. Calor: Milo ris0 p m wide roll olb45 0" , 18 m) wide roll 41 ta• ,o) FIMIIIUPU ly (*$1M 1 MIL 70) Polk Flume mod 8 pilwNM' Fevre 0 0 Them* Ileeleieneo Ft VOW per ASV 0 518; 4.14 pvr inch (0,10 m) at ACTIVITY NUMBER: M2000 - 252 DATE: , 11 -9-2000 PROJECT NAME: . .NORI SUSHI AND GRILL SITE ADDRESS: _._896 SO SUITE NO: _,Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # i , _Revision If After Permit Is Issued DEPARTMENTS: Building givision Public Wo �� DETERMINATION OF COMPLETENESS: (rues,, Thurs.) Incomplete Complete Comments: TUES /THURS ROUTING: Please Route Aft, PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention El MAX. II -LV•W Structural Structural Review Required REVIEWER'S INITIALS: A_RSZY 1.F CDERE.CTI N : (ten days) Approved L__.. Approved with Conditions REVIEWER'S INITIALS: CO EST, ON D E M NA ON: Approved L Approved with Conditions L REVIEWER'S INITIALS: Planning Division Permit Coordinator lir DUE DATE: 1 1 Not Applicable No further Review Required DATE: DUE DATE 12- 12-2000 Not Approved (attach comments) E1 DATE: DUE DATE ..... Not Approved (attach comments) LJ DATE: , • :: .: I' Apt t ,t rb i' i. tLi 't"�x. ';!' ?; of'Efri' uluf -S i Ara 5PAc.0 - := MEJAL g{{'FT 'Dir t tei ti. Ct~as5_.' •NooV I understand that the Flan f ie K e rip ^ l:a+s c.re subject to errors and or;isski as a ci- a pprevaPof plans does not authorize the vlolat,on of any adopted code or ordinance. Receipt of con:- tractor's copy of approved plans'ackr owteec & d 1,s cA: a 00144 W*FP.21 • wAt.G 9ff' S 1' 'Zoe F f e i e N i o` FI 3,r* ra«e irt 1kri -4 t. F • are. pe , . Li J ) ,. Date : 2'..6 Permit No / SEPARATE PERMIT REQUIRED FOR. OyIECHANIOL E-LECTRi,CA•L' ❑. PLUIMEBING 0 OAS. PIPING . .::.. . CITY OF TUKWILA BUILDING DIVISION j,IZE� c CV (.41' • PICT EP, e e we P > to CAftilac.1Vfz I1 — .. /UO1 vtiE4..7T 6a 6 LY 5.2'112 t'p ALwP, :.. '`. n olz,Tri4 0.1 /oar >. R V SJONS OF 'WON< WITHOUT PR'.!Or'. (v'AL 0 lt Tilt � .A' BOIL D1,I�afl O!r.. • , tL A D MAY Iier.LUL AD DiTiot AI PLRtdHE.y E Ei i ': DIFFUSER, GRILLE & REGISTER SCHEDULE EQUIP LETTER SERVICE MOUNTING TYPE DESCRIPTION ACCESSORIES FINISH MANUF MODEL NO A SUPPLY LAY –IN 24 "x24" OPPOSED BLADE DMPR WHITE TITUS TMSA 8 LINEAR SURFACE 24" - -- WHITE TITUS ML -39 C RETURN LAY –IN 24 "x24" ____ WHITE TITUS 50F D RETURN LAY –IN 12 "x12" ____ WHITE TITUS 50F AIR BALANCE SCHEDULE UNIT SUPPLY RETURN OUTSIDE NUMBER - AIR AIR AIR EXHAUST NOTES AIR RTU -1 2655 1930 725 - -- – EF -1 - -- - -- - -- 3625 – MUA -1 2540 - -- 2540 - -- – TOTAL 5195 1930 3265 3625 – 1. EF -1 AND MUA -1 PROVIDED BY KITCHEN CONTRACTOR. 2. BUILDING NEGATIVE PRESSURE 360 CFM. 3" PVC AIR INTAKE &3"PVC FLUE EXHAUST UP TH,!J ROOF MECHANICAL NOTES: LANDLORD NOTES: HVAC PLAN 1/4=1'-4 " EXHAUST HOOD PROVIDED BY KEC EXHAUST FAN PROVIDED BY KEC 18 ° x16 ° DUCT UP TO EXHAUST FAN MAKE –UP AIR UNIT � PROVIDED BY KEC SMOKE DETECTOR IN SUPPLY AR AND RETURN AR DUCT 26"x27' RETURN AIR OPENING 12"0 DN WITH BALANCING DAMPER (TYP) 1. FIRE SPRINKLER, FIRE ALARM, AND ROOFING WORK BY LANDLORD'S CONTRACTOR AT TENANT EXPENSE. 2. FLEX DUCT SHALL BE PRE INSULATED WITH 1 -1/2" THICK FIBERGLASS, 1/J DENSITY FLEXMASTER OR EQUAL. PROVIDE SPIN –IN FITTING WITH INTEGRAL VOLUME DAMPER AT EACH TAP. MAXIMUM FLEX RUN – FIVE FEET (5' -0"). 3. FINAL AIR SYSTEM TESTING AND BALANCING SHALL BE PERFORMED BY THE TENANT'S DESIGNATED CONTRACTOR. 4. UTILITIES ARE AVAILABLE AT DESIGNATED LOCATIONS WHICH MAY NOT BE IN THE DEMISED PREMISES. COORDINATE THE FINAL CONNECTION OF ALL UTILITIES WITH THE LANDLORD'S FIELD REPRESENTATIVE. 5. MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL DUCTWORK (BLACKIRON WIELDED DUCT) & EXTINGUISHING SYSTEM PER NFPA 96. PROVIDE ANSUL TYPE SYSTEM IN ALL EXHAUST HOODS, PROVIDE SPRINKLER HEADS & ACCESS IN EXHAUST DUCTS AS REQUIRED BY NFPA 96. 6. ALL WORK, EQUIPMENT, AND INSTALLATIONS SHALL CONFORM TO ALL APPLICABLE CODES. 7. FIELD VERIFY LOCATION OF ROOF OPENINGS IN CONJUNCTION WITH EXISTING ROOF STRUCTURE. 8. ALL CEILING PLENUM CAVITIES SHALL BE PLENUM RATED FOR CEILING PLENUM RETURN AIR PASSAGE WAY. 9. PROVIDE APPROVED FIRE DAMPERS IN ALL DUCTWORK RUNNING THROUGH FIRE RATED WALLS, FLOORS AND ROOF. 0. ALL AIR INTAKES LOCATED ON ROOF TO MAINTAIN A 15' -0" SEPARATION FROM EXHAUST OUTLETS. 1. ALL PIPING SHALL BE INSULATED INCLUDING WASTE PIPING SUBJECT TO COLD WATER WASTE, CONDENSATE, ETC. 2. TENANT MUST USE A LANDLORD APPROVED ROOFING CONTRACTOR FOR ALL ROOF PENETRATIONS. 3. ALL HVAC WORK TO BE PERFORMED IN COMPLIANCE WITH LOCAL CODES AND LANDLORD CRITERIA. 4. TENANT IS RESPONSIBLE AT JOB COMPLETION TO HIRE INDEPENDENT AIR BALANCE CONTRACTOR TO BALANCE SPACE AND SUBMIT REPORT TO LANDLORD. 5. OBTAIN "TYPICAL TENANT DRAWINGS" FROM LANDLORD'S TENANT COORDINATOR PRIOR TO BID. SENS. LOAD TOTAL LOAD TOTAL CFM ROOFTOP AIR HANDLING UNIT SCHEDULE MFGR- & MODEL CARRIER 480J0007 (6 TON) CFM 2655 SP 0.5" H.P SEE ELEC VOLTAGE SEE ELEC ENT. DB 77.5 ENT. WB 63.1' OPERATING WEIGHT 680 LBS SPACE LOAD CALCULATIONS DESIGN TEMPS SUMMER 84 DEG F 65 DEG F 75 DEG F OADB 0.A.W.B. IADB GAINS ROOF LOAD BTUH GLASS LOAD - -- 8TUH WALL LOAD - -- BTUH LIGHTS 7336 BTUH PEOPLE 6 PEOPLE (SENS) 1467 BTUH PEOPLE (LAT) 1620 BTUH MISC. EQUIP. 46912 BTUH VENT. HEAT GAIN', 6949 BTUH 788 WITH ROOF CURB & ECONOMIZER OUTSIDE AIR CFM 725 SENSIBLE M.B.H. 63.30 TOTAL M.B.N. 77 HEATING CAP 56.83 LEAVING DB 55.1 LEAVING WB 53.1 WINTER 0.A.D.B. 21 DEG F I.A.D.B. 70 DEG F LOSS 1976 NOTE: BTUH BTUH BTUH 37835 BTUH 64632 BTUH HEAT REQ'D, 39811 BTUH 69553 BTUH VENTILATION 725 CFM 2655 BTUH SZ HVAC SYMBOLS NEW DUCT EXISTING DUCT X RETURN GRILLE 0 THERMOSTAT BALANCING DAMPER POINT OF CONNECTION e SUPPLY DIFFUSER FACE MOUNTED VOLUME DAMPERS SHALL BE USED IN GYPSUM CEILIINGS. BALANCING DAMPER W/ LOCKING QUADRANT FLEXIBLE DUCT, 5 FT. MAX. LENGTH, MAX. ALLOWABLE OFFSET FROM CENTERLINE TO BE HALF OF NECK DIAMETER ROUND RIGID DUCT �■IIIII"I' ®' i DIFFUSER —� NOTE: — CONICAL TAKEOFF SUPPLY DUCT 7 — FLEXIBLE DUCT TOP DETAIL IS TO BE FOLLOWED WHEN CENTERLINE OF DIFFUSER I5 UNDER THE DUCT ENOUGH TO PERMIT A BOTTOM TAKEOFF WITH A FLEXIBLE DUCT OFFSET OF LESS THAN HALF THE NECK DIAMETER. BOTTOM DETAIL TO BE USED IN ALL OTHER CASES. CEILING DIFFUSER RUNOUT DETAIL NO SCALE — WORM DRIVE CLAMPS OR DRAWBANDS AND ADHESIVE Name Date Registra 118A0 PLAN General Notes Revision /Issue Dunham Associates Consulting Engineers 8200 Normanda6 600, #500 Minneapolis, MN 55437 -1075 Tel: 952420 -1400 Fax: 952- 820 -2760 OunhareAssociates.com Certification. I hereby certify that this drawing was perpared by me or under my direct supervision and that I am a duly Licensed Professional E ngineer unde ,.s- ° ne State of W e,2r f SLgnalur�� NOFIO SUSHI SOIPTd8CB94TE8 NAME, WASHON8TON ON A Date J. CGHO DEMON INC. WIVE 204, 8901 WOODBINE AVE. 88868894, ON, CANADA LER 9M4 488,.: (909) 949-1783 FAX: (905) 948 -9790 J ( 400995.08 Date 5119818, 2000 Scale \ 1/4" =94" Sheet 941 1 OEt4 E I!,LcL NO. I NA...AL TAG 1 .1\AI PACKAGE # -T.7 LOCATION SWITCHES ROOFTOP STARTERS OPTION � FANS CONTROLLED LOCATION QUANTITY TYPE 0 H.P. VOLT. 1 Q 31111000 Utility Cabinet Left Hood # 1 Utility Cabinet Left 1 Light 1 Fan BLOWER J Exhaust 3 1,500 208 NRTPB 080245 44 -3/4 30 -1/2 36 25 29 25 Supply 3 1.000 208 RTP MODEL EXH FAN AE CE A B C D F G H L M N P Q R S T FILTD SIZE ER QTY AN BLOWER J K j V W MAX:: WEIGHT NRTPB 080245 44 -3/4 30 -1/2 36 25 29 25 104 32 -1/2 14 75 20 32 - 1/2 34 42 -1/2 59 23 6 TWO 20' x 25° G -12 13 - 3/4 15 -7/8 N/A N/A 780 LBS NO, PpN ITEM SIZE UTILITY CABINET(S) FIRE SYSTEM 1 # 1 Curb 32.500'W x 75.000'L x 20,000 /20.000'H Insulated Vented QTY Rail 6.000'W x 33000'L x 20.000'H QTY TYPE Rail 6.000'W x 33.000'L x 20.000'H TYPE SIZE HOOD NO. y V FILTER(S) LIGHT(S) MAX. COOKING TEMP, UTILITY CABINET(S) FIRE SYSTEM ELECTRICAL SWITCHES - FIRE SYSTEMS PIPING HOOD WEIGHT TYPE QTY HEIGHT LENGTH QTY TYPE C UTARD LOCATION TYPE SIZE MODEL # QUANTITY LOCATIQN 1 Alum. Baffle w/ Handles 1 16' 16' 5 Incandescent Lights NO Left Ansul R -102 3.0/3.0 - 31111000 1 Light 1 Fan Outside YES 898 LBS. 8 16° 20' HOOD NO. MODEL LENGTH MAX. COOKING TEMP, EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CONFIGURATION SWITCHES ON HOOD TOTAL EXH. CFM RISERCS) TOTAL SUP. CFM RISERCS) END TO END ROW WIDTH LENGTH CFM S.P. WIDTH LENGTH CFM S.P. QUANTITY LOCATION 1 4824 ND -BR 6. 14' 00' 600 Deg, 3625 10' 16' 1813 - 0.520' 2538 NHMUA2,12B 7 430 SS Where Exposed 0.500' 844 1.000 10' 16' 1813 - 0.520' 1 1 FAN UNIT NO. 1111 W1L31MIL,Ii. FAN UNIT MODEL 8 EXHAUST FAN SUPPLY FAN. MODEL TAG CFM S.P. RPM H.P. 0 VOLT BLOWER HOUSING TAG CFM S.P. RPM H.P. - - 0 ' VOLT 1 NRTP.B- NHMUA2.12 - G12 - CNU 245 CNU 245 1269 3625 - 1,000' 793 1.500 3 208 G12 NHMUA2,12B 7 2538 0.500' 844 1.000 3 208, FAN UNIT NO. FAN UNIT TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 6.00' YES NO 2538 5.000' 36.000' YES 1269 HOOD NO WIDTH LENGTH CHEESE MELTER SUPPORTS TOTAL SUPPLY CFM BOOT(S) WIDTH LENGTH ANGLE CFM S.P. 1 6.00' 186.00' NO 2538 5.000' 36.000' Straight 1269 0.110' 5.000' 36.000' Straight 1269 0.110' 48 m I 3600 Hood #1 ® \ FAN UNIT NO, BURNER SIZE BTU's TEMP. RISE FREEZE STAT OUTSIDE AIR OVERRIDE TEMP. SELECTOR LOCATION GAS TYPE 1 12' 246694 90 deg F / YES Unit Natural ANSI FAN & L SWITC OOD INFORMATION BACK RETURNS) 2' HIGH SUPPLY COLLAR CONNECTION 7 27' TYP. 100W VAPORPROOF INCANDESCENT LIGHT HANGING ANGLE EXHAUST RISER i U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS SLOPED GREASE DRAIN WITH REMOVABLE CUP 48' EQUIPMENT BY OTHERS HOOD #1 PLAN VIEW - 14' 6.00' LUNG 4824ND -BR w®11s Me = = _® 33' MIN 48' MAX HOOD #1 SECTION- VIEW - MODEL 4824 - NDBR 24' NOM 78' TYP, HOOD OPTIONS HOOD NO. OPTION FIELD WRAPPER 18.00' High Front, Left, 18' FIELD WRAPPER FRONT & LEFT REMOVABLE, PERFORATED STA :,_ESS STEEL PANEL JOB LOCATION ALL ELECTRICAL AND PLUMBING CONNECTIONS MUST BE LOCATED BELOW THE BACK RETURN AIR PLENUM DATE 05/11/2000 DWG # NORI SUSHI AND GRILL REV 09/15/2000 BT JOB# 0 DRAWN BY CMS SCALE 8.5' x 11' CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 AND ARE RECOGNIZED BY ONE OR MORE OF THE FOLLOWING: NSF INTERNATIONAL BOCA -ES Report #93 -16 ICBO -ES Report #4416 SBCCI PST & ESI #93137 LOS ANGELES RR #8085 U,L. LISTED #MH12106 0 ® &mtwA swot c = e � la la law - `.. if1ir - -= (T/2Ooe-Z5 z JOB NORI SUSHI AND GRILL LOCATION DATE 05/11/2000 DWG # REV. 1,00 JOB :# 0 DRAWN BY CMS SCALE 8.5' x 11' FAN ACCESSORIES -UP AIR UNITS ROOF TOP PACKAGE (RTP) WITH CNU SERIES UPBLAST EXHAUST FAN DATA EXHAUST FAN CE EXHAUST SIDE IS VENTED 3' CONTINUOUS FLASHING EXHAUST FAN ELECTRICAL DROP ROOF OPENING AE EXHAUST DUCT LOCATION L - 2 SUPPLY DUCT LOCATI A A G -2 EXTERNAL DISCONNECT LOCATED ON SIDE OF UNIT GALVANIZED SUPPLY FAN 20 GA, ALUMINIZED CONSTRUCTION . NOTE 10 FT,I_ HORIZONTAL CLEARANCE FROM SUPPLY FAN INLET TO EXHAUST FAN OUTLET (COMPLIES WITH NFPA 96) GALVANIZED TRUNKLINE nrucnicrnn�c rni rn�ruc eiTi #ppRO' 60 DEC 4260,0 EQUIPMENT RAIL N O9 .. 9 2000 PERMIT CE9.ITER /,SU MAU / / • .7l, / % / %% % / / �/ / % % / //% % / /// / %% % / / % ' / // %%/ // % % / % / / / %% / /�� /%% / // % / / / 6.00 - 3,00 -��� 3.00 I 3600 GHT 48 m I 3600 Hood #1 ® \ � lo --- 7 U.L. Listed Incandescent Lights 10 o0 _ 7,aD III I a I - i "" 1 -___16A0 ---i600 00 . TYPICAL . \ HANGING LOCATION . 4 -BOXES & CONDUIT FOR PREWIRED LIGHTS ANGLE _,, a nn_ 43.50 43.50 07.00 14' Ann. ANSI FAN & L SWITC OOD INFORMATION BACK RETURNS) 2' HIGH SUPPLY COLLAR CONNECTION 7 27' TYP. 100W VAPORPROOF INCANDESCENT LIGHT HANGING ANGLE EXHAUST RISER i U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS SLOPED GREASE DRAIN WITH REMOVABLE CUP 48' EQUIPMENT BY OTHERS HOOD #1 PLAN VIEW - 14' 6.00' LUNG 4824ND -BR w®11s Me = = _® 33' MIN 48' MAX HOOD #1 SECTION- VIEW - MODEL 4824 - NDBR 24' NOM 78' TYP, HOOD OPTIONS HOOD NO. OPTION FIELD WRAPPER 18.00' High Front, Left, 18' FIELD WRAPPER FRONT & LEFT REMOVABLE, PERFORATED STA :,_ESS STEEL PANEL JOB LOCATION ALL ELECTRICAL AND PLUMBING CONNECTIONS MUST BE LOCATED BELOW THE BACK RETURN AIR PLENUM DATE 05/11/2000 DWG # NORI SUSHI AND GRILL REV 09/15/2000 BT JOB# 0 DRAWN BY CMS SCALE 8.5' x 11' CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 AND ARE RECOGNIZED BY ONE OR MORE OF THE FOLLOWING: NSF INTERNATIONAL BOCA -ES Report #93 -16 ICBO -ES Report #4416 SBCCI PST & ESI #93137 LOS ANGELES RR #8085 U,L. LISTED #MH12106 0 ® &mtwA swot c = e � la la law - `.. if1ir - -= (T/2Ooe-Z5 z JOB NORI SUSHI AND GRILL LOCATION DATE 05/11/2000 DWG # REV. 1,00 JOB :# 0 DRAWN BY CMS SCALE 8.5' x 11' FAN ACCESSORIES -UP AIR UNITS ROOF TOP PACKAGE (RTP) WITH CNU SERIES UPBLAST EXHAUST FAN DATA EXHAUST FAN CE EXHAUST SIDE IS VENTED 3' CONTINUOUS FLASHING EXHAUST FAN ELECTRICAL DROP ROOF OPENING AE EXHAUST DUCT LOCATION L - 2 SUPPLY DUCT LOCATI A A G -2 EXTERNAL DISCONNECT LOCATED ON SIDE OF UNIT GALVANIZED SUPPLY FAN 20 GA, ALUMINIZED CONSTRUCTION . NOTE 10 FT,I_ HORIZONTAL CLEARANCE FROM SUPPLY FAN INLET TO EXHAUST FAN OUTLET (COMPLIES WITH NFPA 96) GALVANIZED TRUNKLINE nrucnicrnn�c rni rn�ruc eiTi #ppRO' 60 DEC 4260,0 EQUIPMENT RAIL N O9 .. 9 2000 PERMIT CE9.ITER