Loading...
HomeMy WebLinkAboutPermit M2000-259 - HALBERT RESIDENCEM2000 -259 Halbert Residence 4007 S 117 P1 EXPIRED City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M2000 -259 Type: B -MECH Category: RES Address: 4030 S 117 PL Location: Parcel #: 734060 -0101 Contractor License No: MECHANICAL PERMIT TENANT HALBERT JACK 4007 S 117 PL, TUKWILA WA 98188 OWNER HALBERT JACK E +JULIE L 4007 S 117 PL, TUKWILA WA 98168 CONTACT JACK HALBERT 4007 S 117 PL, TUKWILA WA 98168 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL A NEW FORCED AIR FURNACE IN THE ATTIC, INSTALL NEW DUCT WORK TO EACH ROOM, THE FURNACE WILL BE POWERED BY PROPANE, TANK LOCATED OUTSIDE AND INSTALLED BY SUBURBAN MECHANICAL. UMC Edition: 1997 Valuation: Total Permit Fee: ****,************************************** * * * * * * * * * * * * * * * * * * ** ** * * * * * * * ** — CO rrr rrrr rr rr 1. 2 _:Z. 1 Permit Center A prized Signature Date I hereby certify hat I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain thi uilding permit. Signature : ,4 ∎. Date: ) Print Name: �-'��— � � LA-CZ Title :, LO! ?L_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work 1s suspended or abandoned for a period of 180 days from the last inspection. EXiD AUG 3 0 2001 Status: ISSUED Issued: 12/27/2000 Expires: 06/25/2001 Phone: (206) 431 -3670 Phone: 206 -619 -7670 1,500.00 47.88 Address: 4030 S 117 PL Tenant: HALBERT JACK Tvoe: B-MECH Paecel #: 734060 -0101 *** tit***** **'A*********** * * * * ** * # * *** * * * *M•k * * *•k* * *,k* k * *•k•* k ** *•A *•k *•k * ** k- 4 * *3k ** A Permit Conditions: 1. Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248-6630). No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. All permits, inspection records, and approved plans shall be available at the lob site prior to the start of any con- struction. These documents are to be maintained and avail - able until final inspection approval is granted. All construction `to be done in conformance with approved plans 'end requirements of the Uniform Building Code (1997 Edition) as amended. Uniform Mechanical Code (1997 Edlt1o'rt), and Washington State Energy Code (1997 Edition). 5. Validity of Permit. The issuance of a permit or approval Of plan;, spec,1fications, and computations shell not be con- strued to, be a permit for, or an approval of, any violation ofaany of the provisions of the building code or of any other ordinance of the Jurisdiction. No permit presuming to g1've: authority to violate or cancel the provisions of this code shall be valid. 6. 'Manufacturers installation instructions required on site for,. the b u i l d i n g inspectors review. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not:' The granting of this permit does not presume • to give authority to violate or cancel the p r o v i s i o n s of any other work or local l aws regulating construction or the performance of work. S , igr► atU Print Narne: CITY OF TUKWILA OOP Permit No: M2000-259 Status: ISSUED Applied: 11/13/2000 Issued: 12/27/2000 ate _I,.I.. _4 _ R Project Name/Tenant: Value of Mechanical Equipment: r— — State/Zip: Site Address : <~ t t i� fi" ( - iv1 -V-;1l l ,s� Tax Parcel Number: -- City 13c,tbb cg' to Property Owner:r.— [1....t, b �T 1 3 CLtLi r"-' J�-t c- Phone: ( o2b� ) t �L� ,,~2..;,S Z Street Address: City State/Zip: Fax #: 6) (� (J b Contractor: City / State/Zip: T Phone: ( ) t I/���p � ► �/�}� "�� {�� may/ Street Address: City State/Zip: Fax #: ( ) Contact Person :.. Phone: ( e.) (( e, ,..z 0 Street Address: City State/Zip: Fax #: ( ) BUILDING ! NER OR AUTHORIZED AGENT: Signature: ' cAok, Date: (616100 Print name: 3- Ph: ne: ic21�c, ) (4 541 asst. Fax N: (6)c)(0) t cyl I (.Q Address: j,, lG ) j t `' t '^ �•- City / State/Zip: T `' t I/���p � ► �/�}� "�� {�� may/ Mechanical Permit Application MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): 00 ►7. _ V ni, �p Csv i h ct-�•} }'�'�G I ) 1\}e ta.: Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be iequtred before the permit Is issued OR submit Form H.4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: if the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, n notarized letter from the property owner authorizing the agent to submit this p omit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review • Applications for which no permit is issued within 100 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 100 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: 11/2/99 Huth perniltdoc CITY OF - 'JKWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. I I.0 Date application expires: • , R STAFF USE ONLY Project Number. (�j Permit Number: �"� 256 Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout A, �' Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 x j ,, H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). 10A Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other a licable re uirements of the Washin ton State Nonresidential Ener Code. i t i4 ``�q Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer, Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal .. Heat loss calculations or Form 146. Equipment specifications. 1 PM sukcpasidoc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Su b ,utit /al Re quire /Ile S New Single Family Residence Change -out or re lacement of existin mechanical e ul ment Narrative of work to be done includln: modification to duct work, Installation of Gas Fireplace Narrative with specification of equipment and chimney type. � 4 If using existing chimney, provide a tatter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. • .***************** ********* ** * * * * * * * * *****k * ** *** ***fir* ** * *** ***h flV OF TUKWILA. WA TRANSMIT * ** ** * * * ** * * *** ' � * ** ** * * ** * * * * * * * * * * * * ** 47.88 12/27/00 12z57 SACK HALBERT xrnits !LB TRANSMIT Numbers R9900413 Amounts Payment Methods CHECK Notations Permit kilos M2000 -259 types U -MECH MECHANICAL PERMIT Parcel Nos 734060.0101 Site Address& 4030 8 117 PL Total roses 47.843 This payment 47.99 Total ALL feet && 47.118 Balancers .00 ************* * ***************ir *** ** *A* * *** * ** * * * * * ** * ** *** *fi r Account Coder I>reewr i of 1 an Amount 000/345.890 PLAN CHECK RES 9.5O 000/333.100 MECHANICAL - RES 1 090 12/29 9 7. 0 TOTAL PERMIT NO.: /4' g MECTIANTCAL PERMIT APPLICATIONS INSPECTIONS 0 00002 Pre•const;uction ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00610 Chimney Installation/All Types ❑ 00700 Framing ❑ 01080 Woodstove ❑ 01090 Smoke Detector Shut Off F . 01100 Rough -in Mechanical 01101 Mechanical Equipment/Controls 01102 Mechanical Pip/Duct insul 01105 Underground Mech Rough -in 01 115 Motor Inspection 1400 Fire Final 01800 Final Mechanical 04015 Special -Smoke Control System B CONDITIONS g 0001 No changes to plans unless approved by Bldg Div ❑ 0014 Readily accessible access to roof mounted equipment 0016 Exposed insulation backing material 0019 All construction to be done in conformance w /approved plans ❑ 0002 Plumbing permits shall be obtained through King Co • 0027 Validity of Permit E 0003 Electrical permits obtained through L & 1 0036 Manufacturers installation instructions required on site "BTU maximum allowed per 1997 WA State Energy Code" 0041 Ventilation is required for all new rooms & spaces "Fuel burning appliances "Appliances, which generate...." "Water heater shall be anchored...." *saw Additional Conditions: TENANT NAME: FEES Basic Fee (Y/N) Supplemental Fee (Y/N) Plan Check Fee (Y/N) Furnace/Burner • to 100,000 BTU (qry) Over 100,000 BTU (qty) Floor Furnace (qty) Suspended/Wa1VFioor- mounted Heater (qty) Appliance Vent (qty) Heating/Refrig/Cooiing Unit/System (qry) Boiler /Compressor to 3 HP/ 100,000 BTU (qry) to 15 HP /500,000 BTU (qty) to 30 HP /1,000,000 BTU (qty) to 50 HP /1,750,000 BTU (qry) over 50 HP/1,730,000 BTU (qty) Mr Handling Unit to 10,000 ctmn (qty) over 10,000 cfm (qry) Evaporative Cooler (qry) Ventilation Fan (qty) Ventilation System (qry) Hood (qry) incinerator — Domestic (qry) Incinerator — Comm/ind (qry) Other Mechanical Equipment (qty) Other Mechanical Foe (enter SS) Add'I Fees — Work w/o Permit (Y/N) !asp Outside Normal Hours (hrs) Reinspections (hrs) Miscellaneous inspections (hrs) Add'1 Plan Review (hrs) Pian Review Permit Tech: Date: l )1-19) August 17, 2001 Mr. Jack Halbert 4007 So. 117th Place Tukwila, WA 98168 RE: Permit Status M2000.259 Site Address: 4030 So. 117th Pl. Dear Mr. Halbert: City of Tukwila Department of Community Development In reviewing our current permit files, it appears that your permit for installation of furnace in Halbert residence issued on December 27, 2000, has not received a final inspection as of the date or this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit Is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 431.3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, KCit ,, . Kathryn A. Stetson Permit Technician Xc; PQ It Fllc No, M20000259 - Duane Griffin, Building Official Steven M. Mullet, A Steve Lancaster, Dirt 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.43! -3670 • Fax: 206.431.3665 it 1997 UNIFORM MECHANICAL CODE 305.4 Prohibited Connections. Equipment shall not be con- nected to a fuel supply by means of a hose. EXCEPTIONS: 1. Movable laboratory or shop equipment using approved fuel hose material not exceeding 6 feet (1830 mm) in length. 2, Outdoor portable appliances using an approved outdoor fuel hose material not exceeding 15 feet (4512 mm) in length connected to an approved outdoor shutoff valve and piping. Equipment shall not be connected to fuel piping by quick -dis- connect devices, swivel joint mechanisms or devices that rely on the use of gaskets, ferrules or similar compression sealing meth- ods unless such fittings are listed for the intended use and approved for the specific installation. SECTION 306 — ELECTRICAL CONNECTIONS 306.1 General. Electrical connections to equipment regulated by this code shall be in accordance with the Electrical Code. 306.2 Means of Disconnect. An approved, independent means of disconnect for the electrical supply to each piece of equipment shall be provided in sight of the equipment served when the supply voltage exceeds 50 volts. 306.3 Service Receptacle. A 120 -volt service receptacle shall be located within 25 feet (7620 mm) of, and on the same level as, the equipment for maintenance. The service receptacle shall not be connected on the Toad side of the required means of disconnect. 306.4 illuminntlon. Permanent switch controlled lighting shall be installed for maintenance of equipment required by thin code to be tu:cessiblo or readily accessible. Such lighting shall provide sufficient illumination to safely approach the equipment and per- form the tasks for which access is provided. Control of the lighting shall be provided at the access entrance. EXCEPTIONS: 1. When rued lighting of the building will provide the required illumination. separate illumination is not required. 2. Equipment located on the roof or exterior wall of a building nerd not be provided with permanent lighting, SECTION 307 — ACCESS AND SERVICE SPACE 307.1 General. Equipment requiring routine inspection or maintenance shall be provided with sufficient access to allow Inspection, maintenance and replacement without removing per- manent construction or other equipment or disabling the function of required fire- resistant construction. 307.2 Equipment in Rooms. Rooms containing equipment requiring access shall be provided with a door and an unobstructed passageway measuring not less than 36 inches (914 mm) wide and 80 inches (2032 mm) high. EXCEPTION: Residential•typc appliances installed in a compart• meat, alcove, basement or similar space may be accessed by an open. ins or door and an unobstructed passageway measuring not less than 24 inches (610 mm) wide and large enough to permit removal of the largest appliance in the space, provided that a service space of not less than 30 inches (762 mm) deep and the height of the appliance, but not less than 30 inches (762 mm) is present at the front or service side of the appliance with the door open. 3073 Equipment in Attics. Attics containing equipment requiting access shall be provided with the following: 1. An access opening large enough to remove the largest piece of equipment, but not less than 30 inches by 22 inches (762 mm by 559 mm); 2. An unobstructed passageway which: 305.4 307.5 2.1 is large enough to remove the largest piece of equipment but not less than 30 inches (762 mm) high and 30 inches (762 mm) wide, 2.2 Is no more than 20 feet (6096 mm) in length when measured along the center line of the passageway from the access opening to the equipment, and 2.3 Has continuous solid flooring not less that 24 inches (610 mm) wide throughout its length; and 3, A level service space at least 30 inches (762 mm) deep and 30 inches (762 mm) wide located at the front or service side of the equipment. EXCEPTION: The passageway and level service space may be omitted if the equipment can be serviced and removed through the access opening. 307.4 Equipment under Floors. Underfloor spaces containing equipment requiring access shall be provided with the following: 1. An access opening large enough to remove the largest piece of equipment, but not less than 30 inches by 22 inches (762 mm by 559 mm); 2, An unobstructed passageway which: 2.1 is large enough to remove the largest piece of equipment but not less than 30 Inches (762 mm) high and 30 inches (762 mm) wide, and 2.2 Is no more than 20 feet (6096 mm) in length when measured along the center line of the passageway from the access opening to the equipment; 3, A level service space at least 30 inches (762 mm) deep and 30 inches (762 mm) wide located at the front or service side of the equipment; and 4, Where the depth of the passageway or the service space exceeds 12 incites (305 mm) below the adjoining grade, the wails of the passageway shall be lined with concrete or masonry extend- ing 4 inches (102 mm) above the adjoining grade and have suffi- cient lateral-bearing capacity to resist collapse. EXCEPTION: The passageway may be omitted If the level service space is present with the access open and the equipment can be serviced and removed through the access opening, 307.5 Equipment on Roofs or Elevated Structures. Roofs or elevated structures containing equipment requiring access shall be provided with the following: 1. An approved means of permanent access, the extent of which shall be from grade or door level to the equipment and its level service space. Such access shall not require climbing over obstructions greater than 30 inches (762 mm) high or walking on roofs having a slope greater than 4 units vertical In 12 units horl- zontal (33% slope). EXCEPTIONS: 1. Equipment may be accessed by a portable lad. der on the single•story portion of a Group R Occupancy or a Group U. Division 1 garage or carport. 2, Equipment may be accessed by portable ladder on the single. story portion of an existing building that does not exceed 16 feet (4880 mm) in height. 2. A level service platform at least 30 inches (762 mm) deep and 30 inches (762 mm) wide located at the front or service side of the equipment. The sides of the service platform shall be provided with a substantial railing not less than 42 inches (1067 mm) high and constructed so as to prevent the passage of a 21 -inch- diameter (533 mm) sphere where a side of the platform is within 10 feet (3048 mm) of a drop greater than 30 inches (762 mm). Ladders and catwalks providing the required access shall be as required by the relevant safety regulations but shall not be less than the following: 19 3 GAS FURNACES M CD 0 :=1 }�-a p m m r � C.4.9 X m Models with Input Rates from a 45 000 to 150,000 BTU /HR UGPH- SERIES nd m RUUD SILHOUETTE" IE 80% AUF.UIE.t UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-448 REV. 2 Supersedes Form No. 022.448 Rev. 1 The Ruud° Silhouette` A line of upflow /horizontal gas fur• naces are designed for utility rooms, closets, alcoves, or attics. Because of the Silhouette's Iow•profIlo 34 Inch (864 mm] height, the upflow model can also be used to satisfy most applications that traditionally call for a horizontal furnace. The design is certified by the American Gas Association. Canadian models are certified by the Canadian Gas Association. Features 1 Patented Turbulex` Heat Exchanger, constructed of both stainless and aluminized steel for the maximum in corro- sion resistance. • Low profile "34 inch" design is lighter and easier to hen dle, and leaves room for optional equipment. ▪ Convertible from upflow to horizontal left or right without field conversion. ▪ Left or right side gas and electric inlet connections with quick, simple change. 1 Hot surface ignition models equipped with remote sense, feature an integrated board with humidifier and electronic air cleaner hookups. MODEL UQPH• A 1 C E REDUCED CLEARANCES (111. (mml SIDE BIDET TOP FRONT L15w kTI 04.05 14 1356) 12 (326j 10 /a (263) El 11 0 4 (1021 f2. 0 1 (25) 3 (761 6 115211 85 (38.6) 06, 07 Man 16 "3214151 12 isi 15 ' 13811 0 3 1761 '2 , 0 1 (2 5) 31761 6 (152 (2, 105 :47.61 10 (A) 11=211 16 1415) 12 1308) mmiu 0 3 17611 0 11=11 3 (761 6 (162) :1 115 ;52.21 10 (8) EOM 19 igi 18'/2 (470) 0 0 0 Mill 3 (76) 6 [152) a 120 ,54.4) 23"/32 (593) 15 /e (397) w 22 (559) 0 0 0 Mall 3 (761 6 (152) a 140 163.5) 24 (622) 23 "/32 (593) 15 /8 (397) c1) 22 (559) 0 0 0 1 (25) 31761 6 1152) 4 150 (68) NOTES: ' Mav reauire a 3' 176 mml to 4'1102 mml or 3'176 mmt to 5'1127 mml adapter. 4- LEFT END 24 - (622 mm[ ( 1 Designates Metric Conversions (tA mm[ 24"'/M" 1616 mm) --• 14 mm(• 11 NO (202 mml OAS I LOW VOLTAGE CONNECTION ELECTRICAL I CONNECTION 26 3 /10" 26° /8' (691 mm) (070 mm[ FRONT OOTTOM VIEW TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) (mml RIOHT END WARNING HIP) 1lllifdnl,l ► , N(►I AF I'III►VI I� (►11 Ill (,OMMI NI)) I► I OIZ IN!,IAI I AI II ID l i n ( , i ( W I T H n(;CI I ►DHli', I ALINO UPWARD!) 1s May be 0' (0 mmj with type B vent. 3 May bo 1' (25 mm) with type B vent. Furnaces must be vented In accordance with ANSI 221.47.1993 • CAN /COA•2.3•M93 venting table guidelines included with each furnace, and in accordance with local codes. 5 €sm4i Q x noOre... 3 & WWI 11•0....Var.•44/10..at -at • V" CONC. WAIL FOOT IN6 .4 2 4.11”: .. • • • At :V .44 ' 1 ...... CULT Kt" ATTIL.10 ESOrreivi O Fic0e, 3 CZ CIEW10 o Net.) C,) fLL NO12:114 WuTH own EX *Tit) 61 FROIOT OF 14005E. ISTJNA CAA I MY SMACT#24,tie • < ..." ..1.0,a 1.a. 4,14a NH,. - LJ STA, r2...5 TO BASEMENT its •,,•, ...1....,.. I, Ma ll a/t. AO •Ps a • .4 , ii. ■•• a 1 =Mr 4,64" 4.14..15....d.• • 51 13110.4. •4114.16•0.1111... a ■41 ; ■4 a 2. SY ts . ' , • 5 Lima U6Or to-N\ AII=Ma MEM' 3 17.1/11RTITA Ai4 buou OF 14005E EXismtbus. r.U4M 1 NI SMKfr._ez.me 3. STAI R...5 TD EASEMENT J 2A •..r.r. •.e.w w .,L • K is VEAV "TLS Q 1•11011••••• • room IICAL6: 3I1G APPROVCO 111Y: I Understand that t'ne Plan Ctva k approval3 ar sub rct to errors and omissions and approval of plans roes not authorize the violation of any adopted code or ordinance. Receipt of con - tractor's cope of approved plans acknowledged. By Date I °Z`7 Permit No. PERMIT ' f'•. k.. ti xi �.�1t' .L D FOR: • :.ECI-IANICAL O ELECTRICAL O PLUMBING GA S PIPING CITY OF TUKWILA BUIL• NG DIVISION CITY O � �R���� II.A OEC 19 2000 AU!1_1510 c; t-5 v 1 DATES I I ?too b lw1•46041 6444I1JAL ck.kk - A-4) rm Nov ; � 200 {,{'{" 11 C.f 1151.1' acv I • DRAWN BY S,c IC I4• / Q) DRAWING NUMRtR 1 Z, v§ Op MOM NOM ' 11 SMOM M31It 10. 3 .7v" act, 1,t/900 (1 7 Q1.. ,Lx/1d hX Z df) .:710a v rg vn.L,5, of N 1 "*4 .a...._a....... ;1111. 0 10 7117 a) x2ZX*f,�.'2 .11,11•4.4.1“ a•SS,• .i aa4 t - .*S.4 _ ♦. rsa- .N.!a.asa Varia a. a. fl fl+ aa++.r•• j r 1 3 1 . 9 0 111 5 ,1= M 7C1 ;o 914 m • 99CYciet . �P7e1 P1 Yfl01 IN _•11•1...,1.. 1e` 41, *2£ t1 .. . 9(111$1 hq .r,• JJ Jtani Alta, 1Z$OPer rue xmc..e FeoN) r V ifi* tr1/41 •r 31:1. a 3v4 to p SCALE: DATE (ttex, 41111111111111•1011111111.1111■ 111411•111. APPROVED DY I ov Yti tistsdNe tipPRWED c 1 ?Mt * k" . ) i cEtil eg 1 ......,.....___........s...._...p it to,4, KtCE.1 r",,ITY OF 11;VVP ,fik NOV 1 Z FUR MILE P1AN kJ ZUCTWOR,M nt)!- 4 • ' DRAWING RUMORS 13 Dn t 4111111111111111111=111111•11111111111111 ACTIVITY NUMBER: M2000 -259 PROJECT NAME: JACK HALBERT SITE ADDRESS: 4007 S 117 PL Original Plan Submittal Response to Correction Letter #.._ DEPAR_ _TMEN_T_S: B ilding Division DO Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete El Complete Comments: 1PILKOIJII TUES/THURS ROUTIDIG: Please Route REVIEWER'S INITIALS: PERMIr COORr COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions REVIEWER'S INITIALS: minnirma CORRECTION D TE M NATiO : Approved ❑ Approved with Conditions Li REVIEWER'S INITIALS: DATE: 11 -13- 2000 SUITE NO: , W Response to Incomplete Letter # __Revision # After Permit Is Issued Planning Division Permit Coordinator ■ DUE DATE: J �-� 4•Z000 Not Applicable ❑ No further Review Required DATE: DUE DATE 12: 12 -2000 Not Approved (attach comments) LJ DATE: DUE DATE Not Approved (attach comments) El DATE: