HomeMy WebLinkAboutPermit M2000-287 - SOUTHCENTER MALL - SUNCOAST PICTURES (NEVER ISSUED)M2000 -287 Suncoast Pictures 266 Southcenter EXP1 Mall A 020 2 „01 Newer 10ed ED HVAC SYMBOL LEGEND DRAWING DESCRIPTION B RETURN — TCFM YPE —SIZE SIZE OF NECK (EXISTING) GR ILLE A—XX CEILING — TYPE —SIZE Ak 300 (D:ISIING) DIFFUSER CFM 2 LOW PRESSURE SPIN —IN FITTINGS BRANCH DUCT TAKE —OFF (EXISTING) TRANSITION (EXISTING) M I FLEXIBLE CONNECTION (EXISTING) ® DUCT SMOKE DETECTOR (EXISTING) —, MANUAL VOLUME DAMPER (EXISTING) FLEXIBLE DUCTWORK (COSTING) 0 THERMOSTAT (EXISTING) SCHEDULE OF DIFFUSERS, REGISTERS AND GRILLES UNIT '. NO. MANUFACTURER. MODEL SIZE OF DIFFUSER SIZE OF NECK NOTES A B I = 24'.X 24` 24' 2 VERIFY ALL CONDITIONS IN FIELD WITH LANDLORDS STORE PLANNING FIELD REPRESENTATIVE EXISTING LANDLORD OUTSIDE AIR DUCT COSTING LANDLORD CONDENSATE PIPING EXISTING CONDENSING UNIT CU -1 TO REMAIN REUSE AND RELOCATE T —STAT. MOUNT AT 4' -0' AF.F. MaDO AsprAa��� ,' I I lol �'� i IJ ron .t /,Ra , �e, i 4! • a • TE /" a a. _ , / AL4*-A„, AL A L . AL i AO' • NMI efivv"" A * kJ 8 v .. e 41 ■ 1 , . 4 4 L .." 10 A ■ „A" 15 , 4! 1■ �.. ".A ,t-,0616.4,_,sw,w,wydmi. ,,,, . .. O ®. 2� ' • 4wiromdiaw oz. r ---- rA pm ra al § i ug m tit .." ai MECHANICAL NOTES 1. THE CONTRACTOR SHALL REUSE EXISTING AIR HANDLING UNIT AND CONDENSING UNIT. TOTAL MR SUPPLY BALANCE TO REMAIN UNCHANGED. OUTDOOR AR 375 CFM. 2. ALL EQUIPMENT. INSTALLATIONS AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA: 3. REMOVE ALL COMPONENTS MD SYSTEMS NOT BEING- REUSED. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION FROM THE LANDLORD. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL. BID. ALL EXISTING STUB —INS, TAPS, ETC. FOR PWMBING AND MECHANICAL SYSTEMS :WITHIN TENANT'S SPACE. 5. NO FIBERGLASS DUCTBOARD ALLOWED. 6. THE CONTRACTOR SHALL SERVICE AND REPAIR. THE EXISTING EQUIPMENT AND ITS ACCESSORIES AS FOLLOWS: CLEAN ALL COILS, REPLACE ALTERS AND BELTS, INSPECT AND REPAIR OR REPLACE DRIVES, FAN BEARINGS. MOTORS. CONTROL COMPONENTS, VALVES, AND ANY. OTHER ITEM' NECESSARY FOR A COMPLETE' AND PROPERLY OPERATING SYSTEM. 7 EXISTING DUCTWORK TO REMAIN. CLEAN AND REPAIR TO "LIKE NEW' CONDITION. RELOCATE DUCT RUNOUTS AS REQUIRED TO CONNECT TO NEW DIFFUSER LOCATIONS. 8. EXISTING DIFFUSERS AND GRILLES TO REMAIN. CLEAN AND REPAIR TO - LIKE !. NEW' CONINFWN. 9. IF REQUIRED, MATCH NEW DUCTWORK. FITTINGS, DAMPERS, INSULATION. ETC., WITH EXISTING. MAXIMUM FLEXIBLE DUCTWORK IS 5' -0 ". 10. RELOCATE DIFFUSERS AND GRILLES TO UPPER GRID COUNG (SALES AREA). 11.' ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE BY TENANT'S SPRINKLER CONTRACTOR. ALL '... SPRINKLER CONTRACTOR. ALL SPRINKLER DRAWL NGS SHALL BE APPROVED BY FACTORY MUTUAL STOCK AREA TO REMAIN UNCHANGED. EXISTING AIR HANDLING UNIT AND=.1. TO REMAIN REUSE AND RELOCATE EXISTING SUPPLY AR DIFFUSER AND RETURN AR' GRILLE TO EXISTING DUCT HEATER DH -1 TO REMAIN MATCH NEW CEIUNG GRID LOCATION (TYP.) orderstand that e Ran Chad, approvals are 4 ct to errors and omissions aid approval of 'af 4 doais nclt. aufhoiriz.e tha J ..on Of any • adopted a or ordinance.. Receipt Or coil factor', copy of approves: plans acknowledged.. Ey Date Pr SEPARATE PERMIT REQUIRED FOR: ❑ ¢fECHANICAL. ELECTRICAL ❑ PLUMBING 0 GAS PIPING CITY OF TUKWILA BUILDING DIVISION ►UQ FiLE COPY c A1420 2001 MECHANICAL PLAN H i--H 0 1 2 4 HVAC EQUIPMENT EXISTING TO REMAIN EXCEPT AS NOTED IN PLAN MIVISIONS '.LL BE MADE TO OF WO WITHOUT PRiO`! TU'CV:'IL4 BUILDING DIV 8 FEET 1/4" = 1' -0 PECIAL MECHANICAL NOTE: THESE DRAWINGS. ARE PARTIALLY .SCHEMATIC. IN CHARACTER AND MUST NOT. BE SCALED. REFER TO OTHER. DRAWINGS TO DETERMINE WHERE NEW EQUIPMENT IS TO BE LOCATED. THE CONTRACTOR SHALL FTT THE WORK TO THE JOB, CAREFULLY INVESTIGATING THE STRUCTURAL ELECTRICAL, ARCHITECTURAL SPACES AND FINISH. CONDITIONS AFFECTING THE. WORK ACCORDINGLY AND FURNISHING NECESSARY BENDS,OFFSETS,' FITTINGS,. I, , JUNCTIONS, ETC., WHETHER SPECIFICALLY SHOWN OR CALLED FOR OR NOT, AND SEEING THAT THERE ARE NO INTERFERENCES BETWEEN THIS WORK AND THE WORK OF ANY OTHER TRADE 'i EMI 1. EXISTING SUPPLY AR DIFFUSER WITH OPPOSED BLADE DAMPER, TO BE RELOCATED. 2. RETURN AR GRILLE TO BE. RELOCATED: gECE1VE0 I� CR+( OF TUKW DEC 1 g 200g PERMIT CENTER SUNCOAST CONTACT: MUSICIAND GROUP, INC. 10400 YELLOW CIRCLE DRIVE MINNETONKA, MN 55343 KRIS SOBERG (952) 931 -8311 (952) 931 - 8109 CONSULTANTS: ENGINEERING: W.J. SUPFIERLANU Cc ASSOC. 6300 WEST SHAKOPEE ROAD SUITE 140 BLOOMINGTON, MN 55438 KEN SNARE (952) 346-4180 (952) 346 -4181 SUNCOAST MOTION PICTURE COMPANY SOUTH CENTER MALL SEATTLE, WA store 3231 'P'' G-728 'W REMODEL "mis*" 669 -019 number KES FDA • pteimin1"y 11/20/00 in final • bidding ■ mama • nrobit0118 Ircrwim the MECHANICAL I I A ICI MECHANICAL SPECIFICATIONS 15000 - GENERAL PROVISIONS 0.01 PERFORMANCE MECHANICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED. INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANUKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.02 SITE EXAMINATION: MAINE SITE BEFORE BIDDING. CLAM NO EXTRAS RESULTING FROM LACK. OF KNOWLEDGE OF SITE CONDITIONS. IF SITE CONDITIONS REQUIRE MODIFICATION OF THE SYSTEMS. INDICATED IN THESE DOCUMENTS, SO ADVISE ENGINEER, AND IF ACCEPTED BY ENGINEER, INCLUDE COST OF SUCH MODIFICATIONS IN BID. 0.03 JOBSTTE CONDITIONS: ACCEPT SOLE AND 'COMPLETE RESPONSIBILITY FOR CONDITIONS OF. THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.04 FULL FUNCTION: PROVIDE ALL MINOR. ITEMS NECESSARY FOR A COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.05. ADMINISTRATION: PROVIDE EVIDENCE OF UCENSURE,. BONDING, AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE. FUNCTIONS, AS REQUIRED. 0.06 PERMITS PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES_ 0.07 COORDINATTOM CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HERON. REFER ALSO TO STRUCTURAL AND ELECTRICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.08 CURING AND PATCHING CUT AND PATCH AS REQUIRED. CUT OR WELD STRUCTURAL MEMBERS ONLY WITH APPROVAL OF STRUCTURAL ENGINEER. PATCHING SUBJECT TO APPROVAL EN ARCHITECT. 0.09 COSTING FLOORS: TRENCH OR CORE BORE DOSTING FLOORS PER LANDLORD REQUIREMENTS. 0.11 EQUIPMENT SUBSTITUTIONS:. REIMBURSE ELECTRICAL CONTRACTOR. AT NO CHARGE TO TENANT, FOR MS COSTS INCURRED DUE TO..SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.12 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.13 REFERENCE STANDARDS: COMPLY WITH APPLICABLE STANDARDS OF NEPA. ANSI. UL ASIIRAE. AND %TACNA EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY CONFORM WITH CONTRACT DOCUMENTS WHERE. THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.14 LOCAL REQUIREMENTS: .COMPLY WITH. THE REQUIREMENTS OF APPLICABLE CODES. LANDLORD. SERVING. UTILITIES, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD. LOCAL AUTHORITY. AND OTHERS AS REQUIRED. 0.15 SCHEDULE: ORDER EQUIPMENT WITHIN 5 DAYS OF RECENT OF CONTRACT TO MAINTAIN CONSTRUCTION SCHEDULE. 0.16 MATERIALS AND EQUIPMENT: PROVIDE NEW UL LISTED. COMMERCIAL GRADE MATERIALS; DEVICES, EQUIPMENT. AND FDCTURES. SUITABLE FOR ENVIRONMENT REUSE EXISTING' ONLY WHEN COMPUANT' WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION. AND APPROVED BY THE ENGINEER. 0.17 SHOP DRAWINGS: BEFORE ORDERING EQUIPMENT AND MATERIALS, SUBMIT NOT LESS THAN FIVE CERTIFIED' COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR ENGINEERS REVIEW, WHO WILL RETAIN: TWO COPIES. ONLY FURNISH. SYSTEMS AND EQUIPMENT IN COMPLIANCE WITH ACCEPTED : SHOP DRAWINGS. 0.18 INSTALLATION: INSTALL ALL MATERIALS. EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' INSTRUCTIONS. 0.19 LAYOUT: INSTALL ALL PIPING AND DUCTWORK TO PRESENT A NEAT AND ORDERLY APPEARANCE RUN ALL LINES PARALLEL WITH'. BUILDING CONSTRUCTION. MAINTAIN HEADROOM AND EQUIPMENT CLEARANCE.' AND GRADIENT WHERE REQUIRED. ALLOW FOR EXPANSION AND CONTRACTION. 0.20 ACCESS DOORS: PROVIDE ACCESS DOORS OR PANELS FOR ALL CLEANOUTS, DAMPERS, CONTROLS, DEVICES. AND OTHER LIEN'S REQUIRING INSPECTION OR MAINTENANCE. ACCESS PANELS SERVING HVAC COMPONENTS SHALL BE 12-RICHES BY 12- INCHES MINIMUM OR. LARGER TO PROVIDE SUFFICIENT WORKING CLEARANCE FOR COMPONENT BEING ACCESSED. 0.21 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION'. OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT ' 022 0 IN M MANUALS: AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER OR OPERATOR.. THE MANUAL SHALL INCLUDE BASIC DATA RELATING TO THE OPERATION AND MAINTENANCE OF HVAC. SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHA BE CLEARLY IDENTIFIED. WHERE APPLICABLE, HVAC CONTROLS BI O RMA1LON SUCH AS DIAGRAMS, SCHEMATICS,' CONTROL SEQUENCE 'DESCRIPTIONS. AND MAINTENANCE AND CALIBRATION INFORMATION SHALL BE INCLUDED. 0.23 WARRANTY : UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DFrtus IN MATERIALS .AND WORKMANSHIP FOR ONE YEAR FROM DATE OF FINAL ACCEPTANCE DURING WARRANTY PERIOD, REPAIR OR REPLACE DEFECTIVE MATERIALS. EQUIPMENT OR WORKMANSHIP WITHOUT COST TO TENANT '.. 0.24 EQUIPMENT IDENTIFICATION: IDENTIFY ALL APPLCABLE ROOFTOP EQUIPMENT WITH TENANT'S NAME AND SPACE NUMBER, USING Y PANTED OR STAMPED METAL TAG. 0.25 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT. AND DUCT LOCATIONS TO AVOID CONFLICTS WITH OTHER CONSTRUCTION AND, TRADES. DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE. THESE SPECIFICATIONS. 0.27 RATINGS: REFER. TO DRAWINGS AND FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.28' PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS INCLUDED IN THESE SPECIFICATIONS MAY BE REQUIRED FOR THIS PROJECT. 0.29 DOCUMENT ERRORS. NOTIFY THE ENGINEER OF ERRORS. DISCREPANCIES OR .OMISSIONS: BEFORE. CONSTRUCTION_ OR. FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE. BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 1520D - THERMAL AND. ACOUSTIC INSULATION 2.20 NOISE TRANSMISSION:. INSTALL DUCTWORK. FREE FROM CONTACT WITH STRUCTURE OR EQUIPMENT TO PREVENT NOISE TRANSMISSION. 2.30 INSULATION REQUIREMENTS INSULATE SYSTEMS'. AS SPECIFIED ONLY AFTER THEY HAVE BEEN TESTED AND INSPECTED. CLEAN ALL SURFACES THOROUGHLY OF MOISTURE, FOREIGN MATERIAL. GREASE, AND RUST INSTALL INSULATION ' .'CONTINUOUS THROUGH PENETRATIONS. 2.31 INSULATION HAZARDS: USE ONLY '1 INSULATION ADHESIVES, SEALERS, AND COATINGS. WITH FIRE HAZARD RATING NOT TO EXCEED 25 /50/50 FLAME SPREAD: FUEL CONTRIBUTED, AND SMOKE DEVELOPED, IN ACCORDANCE WITH UL 723 AND. ASTM E84. 2.35 EXTERNALLY INSULATED SUPPLY DUCT: INSULATE SHEET METAL DUCTWORK. WITH 1 AND 1/2 -INCH FIBERGLASS BLANKET DUCT. WRAP WITH AN INTEGRAL VAPOR BARRIER FACING, OWENS- CORNING, OR EQUAL THE INSULATION SHALL HAVE MINIMUM R 6.0 HR- SQ.FT. -DEG. F /BTU -IN.' THERMAL RESISTANCE. DO NOT INSULATE PORTIONS OF DUCTWORK WHICH ARE INTERNALLY UNED. DO NOT INSULATE SUPPLY AR DUCTWORK. IN CONDITIONED SPACES UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 2.40 INSULATED FLEXIBLE DUCT: GENERAL ENVIRONMENTAL CORPORATION TYPE 030A OR EQUAL 5' -0' MAXIMUM LENGTH WITH A MINIMUM ELBOW RADIUS OF 1.5 X D AND A MINIMUM R 6.0 HR SQ. FT.- DEG. F /BTU -IN. THERMAL RESISTANCE. USE ONLY FOR FINAL CONNECTIONS TO CEILING DIFFUSERS. 15300 - FIRE PROTECTION 3.10 FIRE PROTECTION EXISTING: RECONFIGURE EXISTING SPRINKLER SYSTEM AS REQUIRED BY ARCHITECTURAL DESIGN, AND IN < ACCORDANCE WITH NFPA 13, APPUCABLE STATE AND LOCAL CODES, AND REQUIREMENTS OF FIRE INSURANCE UNDERWRITERS. 15800' - DUCTWORK AND APPURTENANCES 8.10 SHEET METAL DUCTWORK: A. FABRICATE AND INSTALL . AS RECOMMENDED IN LATEST EDITIONS OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS - -METAL AND FLEXIBLE AND THE ASHRAE GUIDE AND DATA BOOK FOR SHEET METAL DUCTWORK SERVING SUPPLY„ RETURN AND EXHAUST SYSTEMS OPERATING BETWEEN -2.0 IN. -W.G. AND +2.0 IN. -W.G. MAXIMUM PRESSURE. INSTALL WHERE INDICATED QU THE PLANS. DUCT SIZES SHOWN ON THE DRAWINGS ARE NOMINAL INSIDE CLEAR DIMENSIONS. WHERE INTERNAL INSULATION. IS PROVIDED, DUCT SIZES MUST BE INCREASED APPROPRIATELY TO MAINTAIN THE INDICATED DIMENSIONS. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AR TIGHT (5% LEAKAGE AND NOISELESS (NO OBJECITONAL NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE FURNISH ALL REQUIRED DAMPERS. TRANSTIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. B. FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ANSI /ASTM A- 527, LOCKFORMING QUALITY, WITH ANSI /ASTM A -525 G90 ZINC COATING; MILL PHOSPHATIZED FOR EXPOSED LOCATIONS. MINIMUM SHEET THICKNESS AND REINFORCING SHALL BE. AS FOLLOWS DUCTS UP TO 12' WIDEST DIMENSION OR DIAMETER: 26 GAUGE. DUCTS 13' TO 24- WIDEST DIMENSION: 24 GAUGE. DUCTS 25' TO 42' WIDEST DIMENSION: 22 GAUGE. DUCTS 43' TO 84' WIDEST DIMENSION: 20 GAUGE. C. DUCT SEALANT: UNITED DUCT SEALER, OR EQUAL PROVIDE A NON- HARDENING. NON - MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE AS RECOMMENDED BY THE MANUFACTURER SPECIFICALLY. FOR SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. ALL DUCTWORK SHALL HAVE SEALED LONGITUDINAL AND TRANSVERSE JOINTS. WHERE SUP AND DRIVE JOINTS ARE MADE; A SEALER SHALL . BE APPLIED OVER THE '.ENTIRE JOINT AFTER THE DRIVE IS IN PLACE. APPLY A SECONDARY LAYER OF SEALER AT THE CORNERS AFTER THE DRIVE ENDS ARE CRIMPED IN PLACE. ALL LONGITUDINAL SEAMS SHALL BE COVERED WITH A SEALING MASSE. ALL SUP JOINTS, SHALL BE MADE AND COATED, THEN INSERTED INTO THE DUCT '.. OR COLLAR AND SECURED WITH SHEET METAL SCREWS. COVER THE ENTIRE OUTER JOINT AND SCREWS WITH MASTIC.; COVER JOINTS AROUND ALL SPIN-IN FIRINGS... INTERNALLY CLEAN DUCTWORK OF DUST AND DEBRIS. D. SUPPORT MATERIAL& EXCEPT AS OTHERWISE INDICATED, PROVIDE HOT -DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS STRAPS,' TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. E ANY SUPPLY DUCTWORK AND PLENUMS THAT ARE DESIGNED TO OPERATE AT STATIC PRESSURE FROM 0.25 'INCHES TO 2 INCHES WATER COLUMN INCLUSIVE. WHICH ARE LOCATED OUTSIDE OF THE CONDITIONED SPACE OR IN RETURN PLENUMS SHALL HAVE JOINTS SEALED IN ACCORDANCE WITH SEAL CLASS C AS DEFINED IN THE SMACNA HVAG. DUET LEAKAGE TEST MANUAL. PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT WHERE SUCH DUCTS'. ARE DESIGNED TO OPERATE AT STATIC PRESSURES OF 1'. INCH WATER COLUMN OR GREATER. 8.20 DUCTWORK ACCESSORIES: A. BALANCING DAMPERS: AR BALANCE, INC., LOUVERS A DAMPERS. INC., RUSKIN. OR EQUAL PROVIDE: MANUAL. SINGLE OR MULTIBLADE DAMPERS, AS INDICATED AND AS CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS. B. DAMPERS SHALL HAVE RIGID. 2 -IN. X 1/2 -IN. X 10 GAUGE CHANNEL FRAMES, BALL OR BRONZE SLEEVE BEARINGS. 1/2 -IN. POLISHED STEEL AXLES, 16 -GAUGE REINFORCED, FELT-EDGED BLADES (NOT OVER B-IN. WIDE). AND STOP FRAMES AROUND THE ENTIRE PERIMETER. VOLUME DAMPERS IN DUCTS. LARGER THAN 12 -IN. X 6 IN. SHALL BE THE OPPOSED BLADE TYPE DAMPERS IN ROUND. DUCTS AND DUCTS 12 -IN. X'6 -IN. AND SMALLER SHALL BE BUTTERFLY TYPE. ROUND BUTTERFLY TYPE VOLUME DAMPERS SHALL BE 30 GAUGE, GALVANIZED STEEL THROUGH 12-IN. DIAMETER; 28 GAUGE FOR ABOVE 12 -IN. C. ALL DAMPERS SHALL BE EQUIPPED WITH STANDARD QUADRANTS OF SUITABLE SIZE IN EQUIPMENT ROOMS/AREAS AND YOUNG O301A. OR EQUAL. RECESSED -TPE IN FINISHED AREAS. PROVIDE QUADRANT LOCKING DEVICE FOR EACH DAMPER ON ONE END OF THE SHAFT AND AN. END .BEARING PLATE ON THE OTHER END FOR DAMPER LENGTHS OVER 12 -IN. ..PROVIDE EXTENDED QUADRANT LOCKS AND EXTENDED BEARING PLATES FOR EXTERNALLY INSULATED DUCTWORK. APPROVED. MANUFACTURERS ARE VENTFABRICS, AND YOUNG REGULATOR CO. 0. DAMPERS SHALL BE COATED WITH RED ZINC CHROMATE PRIMER OVER A BOND COAT. E VOLUME DAMPERS; SPLITTERS AND DEFLECTOR% SHALL '. BE PROVIDED IN ALL. DUCTS TO PERMIT ACCURATE`. BALANCING OF THE SYSTEM. THE DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE HEATING. AND VENTILATING REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN. PLACE. 8.60 FLEXIBLE CONNECTIONS:' VENTFABRICS, INC., DURO DYNE OR EQUAL PROVIDE FLEXIBLE DUCT CONNECTIONS WHEREVER DUCTWORK CONNECTS TO VIBRATION ISOLATED EQUIPMENT. AND WHERE SHOWN OR NOTED. MAKE AIR -TIGHT JOINTS. PROVIDE ADEQUATE JOINT. FLEXIBILITY' TO ALLOW FOR THERMAL ALVLL, TRANSVERSE AND TORSIONAL MOVEMENT. 15900 SYSTEM CONTROL AND OPERATION 9.11 THERMOSTAT: REUSE AND RELOCATE EXISTING THERMOSTAT TO CONTROL THE OPERATION OF SUPPLY MR UNIT. MOUNT THERMOSTAT AT 4' -0' A.F.F. 15950 TESTING, ADJUSTING, BALANCING 9.51 NEBB OR AMC CERTIFIED TESTING AND BALANCING CONTRACTOR SHALL BE RESPONSIBLE. FOR THE TESTING AND BALANCING OF EVERY HEATING. VENTILATING AND. AR 'CONDITIONING ' SYSTEM. THE PERSON. OR AGENCY RESPONSIBLE FOR BALANCING OF THE SYSTEMS -SHALL DOCUMENT IN WRITING THE AMOUNT OF OUTDOOR AIR BEING PROVIDED AND DISTRIBUTED FOR THE BUILDING OCCUPANTS'- AND -ANY. OTHER SPECIALTY. VENTILATION. TWO (2) COPIES OF A WRITTEN REPORT IN NEBB OR AABC FORMAT SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. 9.52 AIR SYSTEMS SHALL BE BALANCED IN A MANNER TO MINIMIZE LOSSES FROM DAMPER THROTTLING BY FIRST ADJUSTING: FAN SPEED THEN ADJUSTING:. DAMPERS 10 MEET DESIGN. FLOW CONDITIONS. DAMPER THROTTLING: ALONE MAY BE USED FOR AR SYSTEM BALANCING WITH FAN MOTORS OF 1 HP OR LESS, OR IF THROTTLING' RESULTS IN NO GREATER IRAN 1/3 HP FAN HORSEPOWER ABOVE THAT REQUIRED IF THE FAN SPEED WERE ADJUSTED. 9.53 HVAC. CONTROL SYSTEMS SHALL BE TESTED TO ASSURE THAT CONTROL ELEMENTS ARE CALIBRATED ADJUSTED AND IN PROPER WORKING CONDITION. SUNCOAST CONTACT: MUSICLAND GROUP, INC. 10400 YELLOW CIRCLE DRIVE MINNETONKA, MN 55343 KRIS SOBERG (952) 931 -8311 (952) 931 -8109 CONSULTANTS: ENGINEERING: W.J. SUTHERLAND A ASSOC. 6300 WEST SHAKOPEE ROAD SUITE 140 BLOOMINGTON, MN 55438 KEN SNARE (952) 346 -4180 (952) 346 -4181 SUN COAST MOTION PICTURE COMPANY SOUTH CENTER MALL SEATTLE, WA s 3231 ' G -728 b'P0 REMODEL 669 -019 number dram review! KES FDH ■ prePriewly 11/20/00 ■ frill ■ bMARIg ■ permt ■ INYWme MECHANICAL SPECIFICATIONS