HVAC SYMBOL LEGEND
DRAWING
DESCRIPTION
B
RETURN — TCFM YPE —SIZE
SIZE
OF
NECK
(EXISTING)
GR ILLE
A—XX
CEILING — TYPE —SIZE
Ak 300
(D:ISIING)
DIFFUSER CFM
2
LOW PRESSURE SPIN —IN FITTINGS
BRANCH DUCT TAKE —OFF (EXISTING)
TRANSITION (EXISTING)
M I FLEXIBLE
CONNECTION (EXISTING)
®
DUCT SMOKE DETECTOR (EXISTING)
—,
MANUAL VOLUME DAMPER (EXISTING)
FLEXIBLE DUCTWORK (COSTING)
0
THERMOSTAT (EXISTING)
SCHEDULE OF DIFFUSERS, REGISTERS AND GRILLES
UNIT '.
NO.
MANUFACTURER.
MODEL
SIZE
OF
DIFFUSER
SIZE
OF
NECK
NOTES
A
B
I =
24'.X
24` 24'
2
VERIFY ALL CONDITIONS IN FIELD
WITH LANDLORDS STORE PLANNING FIELD REPRESENTATIVE
EXISTING LANDLORD OUTSIDE AIR DUCT
COSTING LANDLORD CONDENSATE PIPING
EXISTING CONDENSING UNIT CU -1 TO REMAIN
REUSE AND RELOCATE T —STAT.
MOUNT AT 4' -0' AF.F.
MaDO
AsprAa��� ,'
I
I lol �'� i
IJ ron .t /,Ra , �e, i 4! • a • TE
/" a a.
_ , /
AL4*-A„, AL A L . AL i AO'
•
NMI efivv""
A * kJ 8 v ..
e
41 ■ 1 , . 4 4 L .." 10 A ■ „A" 15 , 4!
1■
�.. ".A
,t-,0616.4,_,sw,w,wydmi. ,,,, . .. O
®. 2� ' •
4wiromdiaw oz. r ---- rA pm ra al § i ug m
tit .."
ai
MECHANICAL NOTES
1. THE CONTRACTOR SHALL REUSE EXISTING AIR HANDLING UNIT AND CONDENSING UNIT. TOTAL MR SUPPLY
BALANCE TO REMAIN UNCHANGED. OUTDOOR AR 375 CFM.
2. ALL EQUIPMENT. INSTALLATIONS AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA:
3. REMOVE ALL COMPONENTS MD SYSTEMS NOT BEING- REUSED. NO EQUIPMENT OR COMPONENTS MAY BE
ABANDONED WITHOUT WRITTEN PERMISSION FROM THE LANDLORD.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL. BID. ALL EXISTING
STUB —INS, TAPS, ETC. FOR PWMBING AND MECHANICAL SYSTEMS :WITHIN TENANT'S SPACE.
5. NO FIBERGLASS DUCTBOARD ALLOWED.
6. THE CONTRACTOR SHALL SERVICE AND REPAIR. THE EXISTING EQUIPMENT AND ITS ACCESSORIES AS
FOLLOWS: CLEAN ALL COILS, REPLACE ALTERS AND BELTS, INSPECT AND REPAIR OR REPLACE DRIVES,
FAN BEARINGS. MOTORS. CONTROL COMPONENTS, VALVES, AND ANY. OTHER ITEM' NECESSARY FOR A
COMPLETE' AND PROPERLY OPERATING SYSTEM.
7 EXISTING DUCTWORK TO REMAIN. CLEAN AND REPAIR TO "LIKE NEW' CONDITION. RELOCATE DUCT RUNOUTS
AS REQUIRED TO CONNECT TO NEW DIFFUSER LOCATIONS.
8. EXISTING DIFFUSERS AND GRILLES TO REMAIN. CLEAN AND REPAIR TO - LIKE !. NEW' CONINFWN.
9. IF REQUIRED, MATCH NEW DUCTWORK. FITTINGS, DAMPERS, INSULATION. ETC., WITH EXISTING. MAXIMUM
FLEXIBLE DUCTWORK IS 5' -0 ".
10. RELOCATE DIFFUSERS AND GRILLES TO UPPER GRID COUNG (SALES AREA).
11.' ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE BY TENANT'S SPRINKLER CONTRACTOR. ALL
'... SPRINKLER CONTRACTOR. ALL SPRINKLER DRAWL
NGS SHALL BE APPROVED BY FACTORY MUTUAL
STOCK AREA TO REMAIN UNCHANGED.
EXISTING AIR HANDLING UNIT AND=.1. TO REMAIN REUSE AND RELOCATE EXISTING SUPPLY AR
DIFFUSER AND RETURN AR' GRILLE TO
EXISTING DUCT HEATER DH -1 TO REMAIN MATCH NEW CEIUNG GRID LOCATION (TYP.)
orderstand that e Ran Chad, approvals are
4 ct to errors and omissions aid approval of
'af 4 doais nclt. aufhoiriz.e tha J ..on Of any •
adopted a or ordinance.. Receipt Or coil
factor', copy of approves: plans acknowledged..
Ey
Date
Pr
SEPARATE PERMIT
REQUIRED FOR:
❑ ¢fECHANICAL.
ELECTRICAL
❑ PLUMBING
0 GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION
►UQ
FiLE COPY
c
A1420 2001
MECHANICAL PLAN
H i--H
0 1 2 4
HVAC EQUIPMENT EXISTING TO REMAIN
EXCEPT AS NOTED IN PLAN
MIVISIONS
'.LL BE MADE TO
OF WO WITHOUT PRiO`!
TU'CV:'IL4 BUILDING DIV
8 FEET
1/4" = 1' -0
PECIAL MECHANICAL NOTE:
THESE DRAWINGS. ARE PARTIALLY .SCHEMATIC. IN CHARACTER AND MUST NOT. BE SCALED. REFER TO OTHER. DRAWINGS TO DETERMINE WHERE NEW
EQUIPMENT IS TO BE LOCATED. THE CONTRACTOR SHALL FTT THE WORK TO THE JOB, CAREFULLY INVESTIGATING THE STRUCTURAL ELECTRICAL,
ARCHITECTURAL SPACES AND FINISH. CONDITIONS AFFECTING THE. WORK ACCORDINGLY AND FURNISHING NECESSARY BENDS,OFFSETS,' FITTINGS,.
I, , JUNCTIONS, ETC., WHETHER SPECIFICALLY SHOWN OR CALLED FOR OR NOT, AND SEEING THAT THERE ARE NO INTERFERENCES BETWEEN THIS
WORK AND THE WORK OF ANY OTHER TRADE 'i
EMI
1. EXISTING SUPPLY AR DIFFUSER WITH OPPOSED BLADE DAMPER, TO BE RELOCATED.
2. RETURN AR GRILLE TO BE. RELOCATED:
gECE1VE0 I�
CR+( OF TUKW
DEC 1 g 200g
PERMIT CENTER
SUNCOAST CONTACT:
MUSICIAND GROUP, INC.
10400 YELLOW CIRCLE DRIVE
MINNETONKA, MN 55343
KRIS SOBERG
(952) 931 -8311
(952) 931 - 8109
CONSULTANTS:
ENGINEERING:
W.J. SUPFIERLANU Cc ASSOC.
6300 WEST SHAKOPEE ROAD
SUITE 140
BLOOMINGTON, MN 55438
KEN SNARE
(952) 346-4180
(952) 346 -4181
SUNCOAST
MOTION PICTURE COMPANY
SOUTH CENTER MALL
SEATTLE, WA
store 3231
'P'' G-728
'W REMODEL
"mis*" 669 -019
number
KES
FDA
• pteimin1"y 11/20/00
in final
• bidding
■ mama
• nrobit0118
Ircrwim the
MECHANICAL
I I A ICI
MECHANICAL SPECIFICATIONS
15000 - GENERAL PROVISIONS
0.01 PERFORMANCE MECHANICAL CONTRACTOR SHALL PERFORM ALL WORK
SPECIFIED. INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING
FINAL CONNECTIONS, IN A WORKMANUKE MANNER USING WORKERS SKILLED
AND EXPERIENCED IN THE TRADE.
0.02 SITE EXAMINATION: MAINE SITE BEFORE BIDDING. CLAM NO EXTRAS
RESULTING FROM LACK. OF KNOWLEDGE OF SITE CONDITIONS. IF SITE
CONDITIONS REQUIRE MODIFICATION OF THE SYSTEMS. INDICATED IN THESE
DOCUMENTS, SO ADVISE ENGINEER, AND IF ACCEPTED BY ENGINEER,
INCLUDE COST OF SUCH MODIFICATIONS IN BID.
0.03 JOBSTTE CONDITIONS: ACCEPT SOLE AND 'COMPLETE RESPONSIBILITY
FOR CONDITIONS OF. THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY DURING PERFORMANCE OF THE WORK.
0.04 FULL FUNCTION: PROVIDE ALL MINOR. ITEMS NECESSARY FOR A
COMPLETE AND FULLY FUNCTIONAL INSTALLATION.
0.05. ADMINISTRATION: PROVIDE EVIDENCE OF UCENSURE,. BONDING, AND
INSURANCE, AND PERFORM OTHER ADMINISTRATIVE. FUNCTIONS, AS REQUIRED.
0.06 PERMITS PROCURE AND PAY FOR ALL REQUIRED PERMITS AND
SERVICE CHARGES_
0.07 COORDINATTOM CONFORM TO GENERAL CONSTRUCTION CONTRACT
DOCUMENTS EXCEPT AS MODIFIED HERON. REFER ALSO TO STRUCTURAL
AND ELECTRICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER
TRADES.
0.08 CURING AND PATCHING CUT AND PATCH AS REQUIRED. CUT OR
WELD STRUCTURAL MEMBERS ONLY WITH APPROVAL OF STRUCTURAL
ENGINEER. PATCHING SUBJECT TO APPROVAL EN ARCHITECT.
0.09 COSTING FLOORS: TRENCH OR CORE BORE DOSTING FLOORS PER
LANDLORD REQUIREMENTS.
0.11 EQUIPMENT SUBSTITUTIONS:. REIMBURSE ELECTRICAL CONTRACTOR. AT
NO CHARGE TO TENANT, FOR MS COSTS INCURRED DUE TO..SUBSTITUTION
OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING
FROM THOSE INDICATED.
0.12 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE
REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO
PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT.
0.13 REFERENCE STANDARDS: COMPLY WITH APPLICABLE STANDARDS OF
NEPA. ANSI. UL ASIIRAE. AND %TACNA EXCEPT AS SUPERSEDED BY LOCAL
AUTHORITY CONFORM WITH CONTRACT DOCUMENTS WHERE. THEY EXCEED
CODE MINIMUM REQUIREMENTS.
0.14 LOCAL REQUIREMENTS: .COMPLY WITH. THE REQUIREMENTS OF
APPLICABLE CODES. LANDLORD. SERVING. UTILITIES, AND THE LOCAL
AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY
LANDLORD. LOCAL AUTHORITY. AND OTHERS AS REQUIRED.
0.15 SCHEDULE: ORDER EQUIPMENT WITHIN 5 DAYS OF RECENT OF
CONTRACT TO MAINTAIN CONSTRUCTION SCHEDULE.
0.16 MATERIALS AND EQUIPMENT: PROVIDE NEW UL LISTED. COMMERCIAL
GRADE MATERIALS; DEVICES, EQUIPMENT. AND FDCTURES. SUITABLE FOR
ENVIRONMENT REUSE EXISTING' ONLY WHEN COMPUANT' WITH THE
CONTRACT DOCUMENTS, IN GOOD CONDITION. AND APPROVED BY THE
ENGINEER.
0.17 SHOP DRAWINGS: BEFORE ORDERING EQUIPMENT AND MATERIALS,
SUBMIT NOT LESS THAN FIVE CERTIFIED' COPIES OF ALL SHOP AND
EQUIPMENT DRAWINGS FOR ENGINEERS REVIEW, WHO WILL RETAIN: TWO
COPIES. ONLY FURNISH. SYSTEMS AND EQUIPMENT IN COMPLIANCE WITH
ACCEPTED : SHOP DRAWINGS.
0.18 INSTALLATION: INSTALL ALL MATERIALS. EQUIPMENT AND SYSTEMS IN
FULL ACCORD WITH MANUFACTURERS' INSTRUCTIONS.
0.19 LAYOUT: INSTALL ALL PIPING AND DUCTWORK TO PRESENT A NEAT
AND ORDERLY APPEARANCE RUN ALL LINES PARALLEL WITH'. BUILDING
CONSTRUCTION. MAINTAIN HEADROOM AND EQUIPMENT CLEARANCE.' AND
GRADIENT WHERE REQUIRED. ALLOW FOR EXPANSION AND CONTRACTION.
0.20 ACCESS DOORS: PROVIDE ACCESS DOORS OR PANELS FOR ALL
CLEANOUTS, DAMPERS, CONTROLS, DEVICES. AND OTHER LIEN'S
REQUIRING INSPECTION OR MAINTENANCE. ACCESS PANELS SERVING HVAC
COMPONENTS SHALL BE 12-RICHES BY 12- INCHES MINIMUM OR. LARGER TO
PROVIDE SUFFICIENT WORKING CLEARANCE FOR COMPONENT BEING
ACCESSED.
0.21 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER
OPERATION'. OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED
UNDER THIS CONTRACT
' 022 0 IN M MANUALS: AN OPERATION AND MAINTENANCE MANUAL SHALL BE
PROVIDED TO THE BUILDING OWNER OR OPERATOR.. THE MANUAL SHALL
INCLUDE BASIC DATA RELATING TO THE OPERATION AND MAINTENANCE OF
HVAC. SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS
SHA BE CLEARLY IDENTIFIED. WHERE APPLICABLE, HVAC CONTROLS
BI O RMA1LON SUCH AS DIAGRAMS, SCHEMATICS,' CONTROL SEQUENCE
'DESCRIPTIONS. AND MAINTENANCE AND CALIBRATION INFORMATION SHALL BE
INCLUDED.
0.23 WARRANTY : UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF
DFrtus IN MATERIALS .AND WORKMANSHIP FOR ONE YEAR FROM DATE OF
FINAL ACCEPTANCE DURING WARRANTY PERIOD, REPAIR OR REPLACE
DEFECTIVE MATERIALS. EQUIPMENT OR WORKMANSHIP WITHOUT COST TO
TENANT '..
0.24 EQUIPMENT IDENTIFICATION: IDENTIFY ALL APPLCABLE ROOFTOP
EQUIPMENT WITH TENANT'S NAME AND SPACE NUMBER, USING Y PANTED
OR STAMPED METAL TAG.
0.25 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS,
AND ADJUST EQUIPMENT. AND DUCT LOCATIONS TO AVOID CONFLICTS
WITH OTHER CONSTRUCTION AND, TRADES.
DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS
SUPERSEDE. THESE SPECIFICATIONS.
0.27 RATINGS: REFER. TO DRAWINGS AND FOR ADDITIONAL
RATINGS AND REQUIREMENTS.
0.28' PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR
PROJECT REQUIREMENTS, AS NOT ALL ITEMS INCLUDED IN THESE
SPECIFICATIONS MAY BE REQUIRED FOR THIS PROJECT.
0.29 DOCUMENT ERRORS. NOTIFY THE ENGINEER OF ERRORS.
DISCREPANCIES OR .OMISSIONS: BEFORE. CONSTRUCTION_ OR. FABRICATION OF
AFFECTED WORK, OR, FAILING SUCH NOTICE. BE RESPONSIBLE FOR
CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER.
1520D - THERMAL AND. ACOUSTIC INSULATION
2.20 NOISE TRANSMISSION:. INSTALL DUCTWORK. FREE FROM CONTACT WITH
STRUCTURE OR EQUIPMENT TO PREVENT NOISE TRANSMISSION.
2.30 INSULATION REQUIREMENTS INSULATE SYSTEMS'. AS SPECIFIED ONLY
AFTER THEY HAVE BEEN TESTED AND INSPECTED. CLEAN ALL SURFACES
THOROUGHLY OF MOISTURE, FOREIGN MATERIAL. GREASE, AND RUST
INSTALL INSULATION ' .'CONTINUOUS THROUGH PENETRATIONS.
2.31 INSULATION HAZARDS: USE ONLY '1 INSULATION ADHESIVES, SEALERS,
AND COATINGS. WITH FIRE HAZARD RATING NOT TO EXCEED 25 /50/50 FLAME
SPREAD: FUEL CONTRIBUTED, AND SMOKE DEVELOPED, IN ACCORDANCE WITH
UL 723 AND. ASTM E84.
2.35 EXTERNALLY INSULATED SUPPLY DUCT: INSULATE SHEET METAL
DUCTWORK. WITH 1 AND 1/2 -INCH FIBERGLASS BLANKET DUCT. WRAP WITH
AN INTEGRAL VAPOR BARRIER FACING, OWENS- CORNING, OR EQUAL THE
INSULATION SHALL HAVE MINIMUM R 6.0 HR- SQ.FT. -DEG. F /BTU -IN.'
THERMAL RESISTANCE. DO NOT INSULATE PORTIONS OF DUCTWORK WHICH
ARE INTERNALLY UNED. DO NOT INSULATE SUPPLY AR DUCTWORK. IN
CONDITIONED SPACES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
2.40 INSULATED FLEXIBLE DUCT: GENERAL ENVIRONMENTAL CORPORATION
TYPE 030A OR EQUAL 5' -0' MAXIMUM LENGTH WITH A MINIMUM ELBOW
RADIUS OF 1.5 X D AND A MINIMUM R 6.0 HR SQ. FT.- DEG. F /BTU -IN.
THERMAL RESISTANCE. USE ONLY FOR FINAL CONNECTIONS TO CEILING
DIFFUSERS.
15300 - FIRE PROTECTION
3.10 FIRE PROTECTION EXISTING: RECONFIGURE EXISTING SPRINKLER
SYSTEM AS REQUIRED BY ARCHITECTURAL DESIGN, AND IN < ACCORDANCE WITH
NFPA 13, APPUCABLE STATE AND LOCAL CODES, AND REQUIREMENTS OF
FIRE INSURANCE UNDERWRITERS.
15800' - DUCTWORK AND APPURTENANCES
8.10 SHEET METAL DUCTWORK:
A. FABRICATE AND INSTALL . AS RECOMMENDED IN LATEST EDITIONS OF
SMACNA HVAC DUCT CONSTRUCTION STANDARDS - -METAL AND FLEXIBLE AND
THE ASHRAE GUIDE AND DATA BOOK FOR SHEET METAL DUCTWORK SERVING
SUPPLY„ RETURN AND EXHAUST SYSTEMS OPERATING BETWEEN -2.0 IN. -W.G.
AND +2.0 IN. -W.G. MAXIMUM PRESSURE. INSTALL WHERE INDICATED QU
THE PLANS. DUCT SIZES SHOWN ON THE DRAWINGS ARE NOMINAL INSIDE
CLEAR DIMENSIONS. WHERE INTERNAL INSULATION. IS PROVIDED, DUCT SIZES
MUST BE INCREASED APPROPRIATELY TO MAINTAIN THE INDICATED
DIMENSIONS. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH
RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AR TIGHT (5% LEAKAGE
AND NOISELESS (NO OBJECITONAL NOISE) SYSTEMS, CAPABLE OF
PERFORMING EACH INDICATED SERVICE FURNISH ALL REQUIRED DAMPERS.
TRANSTIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES
NECESSARY FOR A COMPLETE OPERATING SYSTEM.
B. FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH
ANSI /ASTM A- 527, LOCKFORMING QUALITY, WITH ANSI /ASTM A -525 G90
ZINC COATING; MILL PHOSPHATIZED FOR EXPOSED LOCATIONS. MINIMUM
SHEET THICKNESS AND REINFORCING SHALL BE. AS FOLLOWS
DUCTS UP TO 12' WIDEST DIMENSION OR DIAMETER: 26 GAUGE.
DUCTS 13' TO 24- WIDEST DIMENSION: 24 GAUGE.
DUCTS 25' TO 42' WIDEST DIMENSION: 22 GAUGE.
DUCTS 43' TO 84' WIDEST DIMENSION: 20 GAUGE.
C. DUCT SEALANT: UNITED DUCT SEALER, OR EQUAL PROVIDE A
NON- HARDENING. NON - MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A
TYPE AS RECOMMENDED BY THE MANUFACTURER SPECIFICALLY. FOR SEALING
JOINTS AND SEAMS IN SHEET METAL DUCTWORK. ALL DUCTWORK SHALL
HAVE SEALED LONGITUDINAL AND TRANSVERSE JOINTS. WHERE SUP AND
DRIVE JOINTS ARE MADE; A SEALER SHALL . BE APPLIED OVER THE '.ENTIRE
JOINT AFTER THE DRIVE IS IN PLACE. APPLY A SECONDARY LAYER OF
SEALER AT THE CORNERS AFTER THE DRIVE ENDS ARE CRIMPED IN PLACE.
ALL LONGITUDINAL SEAMS SHALL BE COVERED WITH A SEALING MASSE. ALL
SUP JOINTS, SHALL BE MADE AND COATED, THEN INSERTED INTO THE DUCT '..
OR COLLAR AND SECURED WITH SHEET METAL SCREWS. COVER THE ENTIRE
OUTER JOINT AND SCREWS WITH MASTIC.; COVER JOINTS AROUND ALL
SPIN-IN FIRINGS... INTERNALLY CLEAN DUCTWORK OF DUST AND DEBRIS.
D. SUPPORT MATERIAL& EXCEPT AS OTHERWISE INDICATED, PROVIDE
HOT -DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS STRAPS,' TRIM
AND ANGLES FOR SUPPORT OF DUCTWORK.
E ANY SUPPLY DUCTWORK AND PLENUMS THAT ARE DESIGNED TO OPERATE
AT STATIC PRESSURE FROM 0.25 'INCHES TO 2 INCHES WATER COLUMN
INCLUSIVE. WHICH ARE LOCATED OUTSIDE OF THE CONDITIONED SPACE OR IN
RETURN PLENUMS SHALL HAVE JOINTS SEALED IN ACCORDANCE WITH SEAL
CLASS C AS DEFINED IN THE SMACNA HVAG. DUET LEAKAGE TEST MANUAL.
PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT
WHERE SUCH DUCTS'. ARE DESIGNED TO OPERATE AT STATIC PRESSURES OF
1'. INCH WATER COLUMN OR GREATER.
8.20 DUCTWORK ACCESSORIES:
A. BALANCING DAMPERS: AR BALANCE, INC., LOUVERS A DAMPERS. INC.,
RUSKIN. OR EQUAL PROVIDE: MANUAL. SINGLE OR MULTIBLADE DAMPERS, AS
INDICATED AND AS CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS.
B. DAMPERS SHALL HAVE RIGID. 2 -IN. X 1/2 -IN. X 10 GAUGE CHANNEL
FRAMES, BALL OR BRONZE SLEEVE BEARINGS. 1/2 -IN. POLISHED STEEL
AXLES, 16 -GAUGE REINFORCED, FELT-EDGED BLADES (NOT OVER B-IN.
WIDE). AND STOP FRAMES AROUND THE ENTIRE PERIMETER. VOLUME
DAMPERS IN DUCTS. LARGER THAN 12 -IN. X 6 IN. SHALL BE THE OPPOSED
BLADE TYPE DAMPERS IN ROUND. DUCTS AND DUCTS 12 -IN. X'6 -IN. AND
SMALLER SHALL BE BUTTERFLY TYPE. ROUND BUTTERFLY TYPE VOLUME
DAMPERS SHALL BE 30 GAUGE, GALVANIZED STEEL THROUGH 12-IN.
DIAMETER; 28 GAUGE FOR ABOVE 12 -IN.
C. ALL DAMPERS SHALL BE EQUIPPED WITH STANDARD QUADRANTS OF
SUITABLE SIZE IN EQUIPMENT ROOMS/AREAS AND YOUNG O301A. OR EQUAL.
RECESSED -TPE IN FINISHED AREAS. PROVIDE QUADRANT LOCKING DEVICE
FOR EACH DAMPER ON ONE END OF THE SHAFT AND AN. END .BEARING
PLATE ON THE OTHER END FOR DAMPER LENGTHS OVER 12 -IN. ..PROVIDE
EXTENDED QUADRANT LOCKS AND EXTENDED BEARING PLATES FOR
EXTERNALLY INSULATED DUCTWORK. APPROVED. MANUFACTURERS ARE
VENTFABRICS, AND YOUNG REGULATOR CO.
0. DAMPERS SHALL BE COATED WITH RED ZINC CHROMATE PRIMER OVER A
BOND COAT.
E VOLUME DAMPERS; SPLITTERS AND DEFLECTOR% SHALL '. BE PROVIDED IN
ALL. DUCTS TO PERMIT ACCURATE`. BALANCING OF THE SYSTEM. THE
DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE
HEATING. AND VENTILATING REQUIREMENTS OF THE CONDITIONED SPACE AND
LOCKED IN. PLACE.
8.60 FLEXIBLE CONNECTIONS:' VENTFABRICS, INC., DURO DYNE OR EQUAL
PROVIDE FLEXIBLE DUCT CONNECTIONS WHEREVER DUCTWORK CONNECTS TO
VIBRATION ISOLATED EQUIPMENT. AND WHERE SHOWN OR NOTED. MAKE
AIR -TIGHT JOINTS. PROVIDE ADEQUATE JOINT. FLEXIBILITY' TO ALLOW FOR
THERMAL ALVLL, TRANSVERSE AND TORSIONAL MOVEMENT.
15900 SYSTEM CONTROL AND OPERATION
9.11 THERMOSTAT: REUSE AND RELOCATE EXISTING THERMOSTAT TO CONTROL
THE OPERATION OF SUPPLY MR UNIT. MOUNT THERMOSTAT AT 4' -0' A.F.F.
15950 TESTING, ADJUSTING, BALANCING
9.51 NEBB OR AMC CERTIFIED TESTING AND BALANCING CONTRACTOR SHALL
BE RESPONSIBLE. FOR THE TESTING AND BALANCING OF EVERY HEATING.
VENTILATING AND. AR 'CONDITIONING ' SYSTEM. THE PERSON. OR AGENCY
RESPONSIBLE FOR BALANCING OF THE SYSTEMS -SHALL DOCUMENT IN
WRITING THE AMOUNT OF OUTDOOR AIR BEING PROVIDED AND DISTRIBUTED
FOR THE BUILDING OCCUPANTS'- AND -ANY. OTHER SPECIALTY. VENTILATION.
TWO (2) COPIES OF A WRITTEN REPORT IN NEBB OR AABC FORMAT SHALL
BE SUBMITTED TO THE ENGINEER FOR REVIEW.
9.52 AIR SYSTEMS SHALL BE BALANCED IN A MANNER TO MINIMIZE LOSSES
FROM DAMPER THROTTLING BY FIRST ADJUSTING: FAN SPEED THEN
ADJUSTING:. DAMPERS 10 MEET DESIGN. FLOW CONDITIONS. DAMPER
THROTTLING: ALONE MAY BE USED FOR AR SYSTEM BALANCING WITH FAN
MOTORS OF 1 HP OR LESS, OR IF THROTTLING' RESULTS IN NO GREATER
IRAN 1/3 HP FAN HORSEPOWER ABOVE THAT REQUIRED IF THE FAN
SPEED WERE ADJUSTED.
9.53 HVAC. CONTROL SYSTEMS SHALL BE TESTED TO ASSURE THAT CONTROL
ELEMENTS ARE CALIBRATED ADJUSTED AND IN PROPER WORKING CONDITION.
SUNCOAST CONTACT:
MUSICLAND GROUP, INC.
10400 YELLOW CIRCLE DRIVE
MINNETONKA, MN 55343
KRIS SOBERG
(952) 931 -8311
(952) 931 -8109
CONSULTANTS:
ENGINEERING:
W.J. SUTHERLAND A ASSOC.
6300 WEST SHAKOPEE ROAD
SUITE 140
BLOOMINGTON, MN 55438
KEN SNARE
(952) 346 -4180
(952) 346 -4181
SUN COAST
MOTION PICTURE COMPANY
SOUTH CENTER MALL
SEATTLE, WA
s 3231
' G -728
b'P0 REMODEL
669 -019
number
dram
review!
KES
FDH
■ prePriewly 11/20/00
■ frill
■ bMARIg
■ permt
■ INYWme
MECHANICAL
SPECIFICATIONS