Loading...
HomeMy WebLinkAboutPermit M98-0005 - BOEING #21-03( PDoel A cQ- Doo5 City of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Address: 3417 S 120 PL Location: Parcel #: 102304 -9069 Contractor License No: JOHANMI173PK TENANT BOEING #21 -03 3417 S 120 PL, TUKWILA WA 98188 OWNER THE BOEING COMPANY PO BOX 3707 M/S 1F -09, SEATTLE WA CONTACT LARRY CARLSON PO BOX 1768, WOODINVILLE WA 98072 CONTRACTOR JOHANSEN MECHANICAL INC. P.O. BOX 1768, WOODINVILLE, WA 98072 * * * ** Perm Permit No: M98 -0005 Type: B -MECH Category: NRES Signature:_ enter Aut 0 ed Signature Date MECHANICAL PERMIT Status: ISSUED Issued: 02/03/1998 Expires: 08/02/1998 Print Name _,_AivOx__L_ 6il1 / Title: Acmg4J'T'- (206) 431 -3670 Phone: 425 -481 -2266 Phone: 206 481 -2266 ********************************************* * * * * * * * * * * ** * * * * * * * * * * * * * * * * ** Permit Description: INSTALL 2 ROOFTOP A /C'S + DUCT WORK. UMC Edition: 1994 Valuation: 32,000.00 Total Permit Fee: 81.88 **** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** I hereby certify that I have read. and examined this permit and.;. know the same to be true and correct. All provisions of law and ordinance's governing this work will be:complied with,. whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work, I am authorized to sign for and obtain this building permit. Date: 2,-3 1 g This permit shall become null and ..void .if the work.is. not commenced within 180 days from the date Of :issuance,' or if the work ; is suspended or abandoned for a period of 18.0 days from the isSt 1'nspection. Project Name/Tenant: j3 oP•-•i rJ G 31.PC . 2l - ems, . - d4fTt -e- Value of Construction: o 0 32 , OC:C:) Site Address: 31 SO. I2.O' Pt— City State /Zip: Tax Parcel Number: 10 7.304 - 'UG Property Owner: im. G _ _ . • , ❑ Temporary Facilities ❑ Tree Cutting Phone: Street Ad. ress: City State /Zip: Fax #: Contact Person: t-Dou C - sca, -/ Ig id Phone: C.4 ) 48t - zzr_.:. Cc:, Street Address: City State /Zip: 7 . O . \1t g e O to i r v i �-E p.. .c Z Fax #: (.y21 (� 3 3 Phone: (4zS") 4-1Sl -ZZ co Co ( u) Contractor: -1 OHf A-r- 1 Sf.. -- k -i i, I C_ . Street Address: 20 t t).‘ t :_ E rJ e.. 6 aqoD City State /Zip: i,J vi c-c.€_. v . t itv €07 Z Fax #: ( 4 � 5 ) 4 ( 3 Phone: Architect: Le-t r^?�1 Street Address: 17J F" . MA-0-61,-)A1.- W A4 S • City State /Zip: iA iC.u) t t_►4 Fax #: Engineer: _., G, �igt.Dg Phone: Street Address: 'F 2 ' s-r I..dA -( 1 , .) /1-c.- u J4�(S City State /Zip: - t cw 1 c.14 Fax #: MISCELLANEOUS. PERMIT. REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY'APPLICANT) Description of work to be done: 2 - r ∎ * _ 1 1 1 - 1 - ( jno r w P Ar ( c15 - D - ' - Will there be storage of flammable /combustible hazardous material In the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 a er indicatin uantitles & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes Bulkhead /Docks Commercial Reroof ❑ Demolition ❑ Fence SI: Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY" SERVICE .BILL'INGS,TO:; ` ' Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby ❑ Channelization /Striping 11 Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous Name: Address: Date app!lcafllec ft.' -lb MISCPMT.DOC 7/11/96 CITY OI' TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 WATER METER. DEPOSIT /REFUND BILLING: Date application expires: " itto OR STAFF USE ONLY Project Num ber: Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUESTFOR'MISCELLANEOUS.PUBLIC WORKS•PERMITS: ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load /Hauling Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Applicatl• t: :n by: (initials) BUILDING OWNER OR AUTHORIZED GE �►, . SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Signature: "MEW �. Date: ' . / ,.. Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 Antennas /Satellite Dishes Print name: ; 6/0 /5 Pho e; 4 .. -2- Fa #: - (.0 Address: 2.-0101 r'- Ave Ar e.- O E – ty /State /Zip: _ n.. , . v n 41,-e. I,a4 G • o Z 2-- ALL MISCELLANEOUS PER,' • APPLICATIONS MUST BE SUBMI WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ›,Zr r p lJlC�71�1 NNS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) • Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant Is other than the.owner, registered ° architect/engineer, ; or contractor:licensed, by the State of Washington, a notarized letter from the property.o,wner authorizing the.agent'ta submit thli permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPM '$,DOQ 7/11/96 toi:o 1 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 Antennas /Satellite Dishes Submit checklist No: 'M-'9 Submit checklist .•:No; .M 1 r il Awnings /Canopies - No signage .Commercial Tenant Improvement Permit , Bulkhead /Dock Submit checklist No: M-10',. El •Commercial. Submit checklist No: : M 6 0 Demolition. ' Submit: checklist No; ; M 3, •M 3a , ' 0 Fences - Over 6 feet in Height Submit checklist No: M -9: Land Altering/Grading/Preloads Submit checklist . No: M -2.: 0 Loading Docks : ' Commercial Tenant Improvement Permit.:; Subrnitchecklist No: H -17 ; Mechanical (Residential & Commercial) Submit : No.,; M-8 Residential , only - H -6, H16 ,' . ." 0 Miscellaneous Public Works Permits . Sulimt'checklist f No; H -9 in Manufactured Housing (RED INSIGNIA ONLY). Submit checklist: No: M- 0 Moving Oversized Load /Hauling Submit checklist. No: M-5. ® Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following exception:'If roof structure to be repaired or replaced Residential Building Permit Submit checklist' . 'No:. M =64; 0 Retaining Walls - Over 4 feet in height Submit checklist : No: M ri Temporary Facilities Submit checklist . 'No: ,W72 i n Temporary Pedestrian Protection/Exit•Systems Submit checklist , ,No; M-4., 0 Tree Cutting . Submit :checklist No M;,.2 ALL MISCELLANEOUS PER,' • APPLICATIONS MUST BE SUBMI WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ›,Zr r p lJlC�71�1 NNS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) • Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant Is other than the.owner, registered ° architect/engineer, ; or contractor:licensed, by the State of Washington, a notarized letter from the property.o,wner authorizing the.agent'ta submit thli permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPM '$,DOQ 7/11/96 toi:o 1 Address: 3417 S 120 PL Suite: Tenant: BOEING #21-03 Type: B-MECH Parcel #: 102304-9069 CITY OF TUKWILA Permit No M98-0005 Status: ISSUED Applied: 01/16/1998 Issued: 02/03/1993 *A** Permit Conditions: 1. All permits, inspection records, and approved plans shall be available at the job site prior,to4he start of any con- struction. These documents.are to . be, ; paintained and avail- able until final inspection approval is granted. 2. All construction t;.o, he done in:conformance with approved plans and requirements of the Uniform Building ('ode (1994 Edition) as aMended, Uniform Mechanical Code .(1994 Edition), and Washington' State Energy Code (1994 Edition),, _ 3. An moving systems 'supplying air in excess of 2000,CFM, to enclosed -spaces within buildings shall be equipped a utomatic shutoff, Automatic%shutoff shall be acCoMplished, by interrupting the power source of the air-moving etlPiPme upon detection of smoke In the main supply-air duct ser'ved by such equipment. UMC 608. 4. MANUFACTURERS INSTALLATION INSTRUCTIONS REQUIRED ON SITE.:' FOR BUILPING INSPECTORS REVIEW,, S. Validity OfPermit, The issuance of r _a',0ermit o ap0fovatof': . plans specifftations, and , computations shall not be con- strued to be a permit for or an'apprOalpf, any viplatton of any of thelwovisioht:ofthe bOtOng, code or of any, otherordinanCe of the 1*.isd1 ction.': No pe'rmit presuming give: to violate /0 'Cancel 'theprOvisions of thi code:Shall; be ia 1 id ; ( All .St'ruet,ur shall be done by cOtifled welds and.' inspected (UE31:306,(a)5)P 7. When'SPctalAnspection is requiredeithe'r.thowner; architeCt en9ineer shall notithe/Tuks.it-l* E3uHdinq »' appoitment of the inspection agenCjes prior &ft' the firStbuilding inspection, , .,Cop1es';0.f411,:specla1 tport shall. be submitted to theBuil*ng Division it tihe1y mann'erReports,shaI'l contOn project naine•! number and'tY'Oe'Of inspection p0141:9 performed. 8. The special inspector shallsUbM t tha 1 igneport stating whether th,e' requir*ngSPeCial J.n0#4ilon was to the best of the'inspeores knowledgIriCOormance with approved plans and'-speCtqCap.Ch*::in applicable workmanship provisions of 9. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presUming to give authority to violate or cancel the provisions of .this code shall be valid. PLAN feirovit REVIEW ROUTING IP ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION ❑ PUBLIC WORKS ❑ M98 -0005 BOEING BLDG 121 -03 DATE 1 -16 -98 FIRE PREVENTION ❑ PLANNING DIVISION ❑ STRUCTURAL ❑ PERMIT COORDINATOR DUE DATE 1 -20 -98 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE ❑ NOT COMPLETE " NOT APPLICABLE ❑ (of I P COMMENTS sAti TUES /THURS ROUTING: PLEASE ROUTE E ROUTED BY STAFF U (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) DATE NO FURTHER REVIEW REQUIRED ❑ DUE DATE 2 -3 -98 APPROVED ❑ APPROVED W/ CONDITIONS NOT NOT APPROVED (attach comments) ❑ REVIEWERS INITIAL DATE CORRECTION DETERMINATION: DUE DATE APPROVED [1 APPROVED W/ CONDITIONS 111 NOT APPROVED (attach comments) ❑ REVIEWERS INITIAL DATE C:ROUTE -F (Corti icadoa of occupancy required. ACTIVITY NUMBER M98 -0005 PROJECT NAME BOEING BLDG 121 -03 REVISION DEPARTMENT: BUILDING DIVISION C1 FIRE PREVENTION ❑ PLANNING DIVISION ❑ PUBLIC WORKS ❑ STRUCTURAL ❑ PERMIT COORDINATOR DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE COMMENTS TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF C❑ (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL rerisii PLAN REVIEW / ROUTI NOT COMPLETE APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: DATE DATE REVIEWERS INITIAL DATE C:ROUTE -F DATE 1 -23 -98 DUE DATE 1 -27 -98 NOT APPLICABLE ❑ DUE DATE 2- 10 -98' APPROVED n APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) 0 DUE DATE APPROVED I I APPROVED W/ CONDITIONS ri NOT APPROVED (attach comments) ❑ (Cent icadon of occupancy requited. ) fi 41 ���'����� �� ��/*«~°`� �`'~ .ITY OF TUKWILA, NA [OGNGM1T +**ki***^*++*A++*+****kk**A*+\**+a1**+k+4*+1(***kA+**k++k**a***A TRANGM%T Number: R9700708 Amount: 81.88 02/03/98 10:26 payment Method: CHECK Notation: JOHAWSEN MECHANI Init: 8LH -'-~' • -- — --^ a.- -_.---_ ^~^-- Pepmit No: M98~0005 'Type: 8~MECH MECHANICAL PERMIT Parcel No: 102304-9069 Qite ` Add|es�: •3417 G 120 PL ' Total Foes: / 81488 |n/s Payment 81.88 Total ALL Pmts: 1 81.88 '' Oa] � a�oe: � . .Q0 4 p++0+A* 4 *«f^++*+^+v+*^**+**+k«*++«+*Ak+A*+f*A*4+f**+'*A6A �a **` Account Code Description' Amoxnt : 00O/345~830' PLAN ��H�Ck - NONR�S `16.38` ' 000/322.100 MECHANICAL - NONRES .� 65.50- 3 / 14'11.?* x ^~� / � ^.. ..~ CITY OF TIftWILA :Department of Community Development 'Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 . t •:::v.. REVISION SUBMITTAL DATE: /-23-98 PLAN CHECK/PERMIT NUMBER:M , 000 PROJECT NAME: 130 # Z ' 03 PROJECT ADDRESS. 34n 5 120 P1 CONTACT PERSON: L /Wi y Congacw PHONE: 1 REVISION SUMMARY: l!/F � /x/e2UZ7h,6 2 J' "TS OF S7/ 2e 1liZ . / 14///i/ 5 7//7-7- /9Az - 2J,O ybc//z Ql Q76vs SUBMITTED TO: c L /6/,z0 „0 r. SHEET NUMBERS) /F 4- 5/a , 2 2 - S/ ,�f,{�,e, "Cloud” or highlight all areas of revisions and date revisions. b 8 / -22 fr.5 - s2. 2 -Z -95 REVISION NO....L. 1c1 9i Mq8- aa� RECEIVED CITY OF TUKWILA JAN 2 3 1998 PERMIT CENTER tjOtid wt y�c. July 13, 1999 Larry Carlson PO Box 1768 Woodinville, WA 98072 RE: Permit Status M98 -0005 3417 South 120 Place Dear Mr. Carlson: In reviewing our current permit files, it appears that your permit for the installation of 2 roof -top a/c units and duct work issued on February 3, 1998 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, 6 -heidd., Brenda Holt Permit Coordinator City of Tukwila Xc: Permit File No. M98 -0005 Duane Griffin, Building OfcIal John W. Rants, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard Suite #100 • Tukwila. Washington 98188 • 12061 4313670 • Fax 120614313665 CITY OF TUKWILA APPROVED JAN 2 9 1998 AS NOIED BUILDING DIVISION January 20, 1998 Dear Mr. Carlson: Building Division: City of Tukwila Department of Community Development Mr. Larry Carlson P.O. Box 1768 Woodinville, Washington 98072 SUBJECT: LETTER OF INCOMPLETE APPLICATION Development Permit Application Numbers M98 -0005 Boeing #21 -03 3417 S 120 PI John W Rants, Mayor 1. Need weight of each of the new R.T.U.'s if they are greater than 400 lbs. 2. Need structural analysis and details to qualify existing roof structure capacity to support applied load of new R.T.U.'s Steve Lancaster, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 16, 1998, was determined to be incomplete. Before your permit application can begin the plan review process the following requirements from the Building Division must be met. Contact Bob Benedicto, Sr. Plans Examiner, at 206 -431 -3670 if you have any questions regarding the following comments. The City requires that two (2) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not required revised plans but requires additional reports or other documentation please submit four (4) copies of each document. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard. Suite #100 • Tukwila. Washington 98188 • 120M 4 7l. ?670 • Far. 12061 Q ?t. ?hhs Mr. Larry Carlson January 20,1998 Page 2 If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, `7citti Kelcie J. Peterson Permit Coordinator Enclosures File: M98-0005 January 20, 1998 Mr. Larry Carlson P.O. Box 1768 Woodinville, Washington 98072 Dear Mr. Carlson: SUBJECT: LETTER OF INCOMPLETE APPLICATION Development Permit Application Numbers M98 -0005 Boeing #21 -03 3417 S 120 PI This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 16, 1998, was determined to be incomplete. Before your permit application can begin the plan review process the following requirements from the Building Division must be met. Building Division: f City of Tukwila John W. Rants, Mayor 1 Department of Community Development Steve Lancaster, Director Contact Bob Benedicto, Sr. Plans Examiner, at 206 - 431 -3670 if you have any questions regarding the following comments. 1. Need weight of each of the new R.T.U.'s if they are greater than 400 lbs. 2. Need structural analysis and details to qualify existing roof structure capacity to support applied load of new R.T.U.'s The City requires that two (2) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not required revised plans but requires additional reports or other documentation please submit four (4) copies of each document. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. M1)t1.Snutheinter Boulevard. Suite #100 • Tukwila. Washlnttton 98188 • 12061431 3670 • Fax 1206) 4313hhS Mr. Larry Carlson January 20, 1998 Page 2 Sincerely, Kelcie J. Peterson Permit Coordinator Enclosures File: M98 -0005 If you have any questions . please contact me at the City of Tukwila Permit Center at (206) 431 -3672. i•l-CQu„9 16irti5o'l City of Tukwila Fire Department Review Control # m(V0605 `21-193 Re: H.V.A.C. at BoDe �6 Q1 Dear Sir: 3N75 1 1 Fire Department Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto- shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required'. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic . shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 2. Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) 3. In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) The installation of wiring and equipment shall be in John W. Rants, Mayor _ n. _ .1_ _ i i i • _ _,_-'__ n_ __r. r+_ _. - T- -I_ ..,r_ nn • nn _ n� _ _ _ ,n.... .••••■ • An i _ 2' . ,nn.. .. �. - .... ,. Page number 2 accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. '(NFPA 72- 1- 5.5.4) 4. When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 5. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, City of Tukwila Fire Department The Tukwila Firb Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Flre Chief U.. ,.l......►..... Conob...• AAA A r....• - net 60 _ n. - /....,. ..... _ .._ _ ....... _ —_ ..... / 24 "x24" S&R UP -TiiRU ROOF 24'x12" S &R UP THRU ROOF 'JO ON ROOF ON ROOF MO4A 20,000 CFM @ 2" S.P., 20 HP 480 -30 NATURAL GAS. DIRECT FIRED 60'F -RISE LINED 10 "x10" 72/48: SOUND TRAP 'SECTI01 100 -100 100 40 °x12" UP. TO ACU' -1: 16"x36" UP TO ACU -1 40 "x12" UP TO ACU -•2 10 TYPICAL a 48/48 UP ! I 20x16 20x20 1O0o 100 1 240 DN X20 .20 "x16" - 36 "x16" SCREENED'< OPENING 72/48 SOUND TRAP SECTION 240 14. 140 :IIMIESI4' VD: VD 140 11 14 1=1111111Z Si =IL it VD VD „ 4 TYPE >H " 3400` 36 x2 CFM -IWG (TYP 6) —, 1.40 / �II `140 aill 140 VD I%03A ON ROOF , 20,000 CFM . p 2" SP 15 HP 480V 30 MOTOR SCALE: 1/8".1' -0 UP: TO SECOND` FLOOR PLAN 20 "x10" DRUM DIFFUSERS 945 CFM } (Tr 10) 56 "x48" UP T0. ON ROOF 18 "x6" DRUM DIFFUSERS 630 CFM (TYP 12) 140 1- 140 120> 120 120 48 "x24" T.G. 48/24 FD -- -- - - -_.. r - - _ _. - -- _ -- - - - -- SEPARATE PERMIT REQUIRED FOR: ❑ yECHANICAL I ELECTRICAL ❑ PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION it • . fit/ ....... 4100 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED - REDRAWN ... OFFICE AREA 21- 03.2,.MEZZ. BY KB DCA -9 -97039 RICE APPROVED • So DATE D9.16.97 12.1.97 5Y REVISION APPROVED TITLE HVAC PLAN BUILDING 21 -03.2 MECHANICAL MASTER COL, R N 1 -45 CURRENT REVISION SYMBOL SHEET 2M12 JOB 0. DCA -9 -97039 Dwc No. CORP.PARK 21 -03- M1 DATE ° ERPIIT CCNTCfl COMP NO. LEGEND: SUPPLY AIR DUCT,; SQUARE OR RECTANGULAR ELBOW FACING TOWARDS SUPPLY AIR' DUCT; SQUARE OR RECTANGULAR ELBOW FACING' AWAY , EXHAUST,' RETURN OR SUPPLY" AIR DUCT ROUND, ELBOW FACING TOWARDS EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY EXHAUST AIR OR RETURN AIR' DUCT, SQUARE OR RECTANGULAR, ELBOW FACING: TOWARDS EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY WY - - -141 0 GENERAL NOTES: =>TEMPMASTER MODEL MSR -C BY-PASS VAV BOX 600 CFM MAX., 240 CFM MIN.; 10'0 INLET, 10 "612 OUTLET, ACOUSTICAL ATTENUATION TITUS.MODEL TMSA CEILING DIFFUSER, 10 ".. NOM INAL NECK SIZE, 300 CFM EACH, MAX NC" =12, FRAME TYPE 3 Q TITUS MODEL TMSA CEILING DIFFUSER, 10" NOMINAL NECK SIZE, 240 CFM EACH, MAX . NC =12, FRAME TYPE 3 TI:TUS MODEL 50R, STEEL BORDER, I/2 "xI /2 "x1 /2 ALUM I NUM. CORE . 1 DUCTWORK GENERAL: NONCOMBUSTIBLE OR CONFORMING TO REQUIREMENTS FOR CLASS 1 AIR DUCT MATERIALS, OR UL 181 ' 2. STEEL DUCTS: ASIM A 525 GALVANIZED STEEL SHEET, ;: LOCKFORMINC' QUALITY HAVING ZINC COATING OF 1.25 OZ. PER SQ. F. FOR EACH SIDE IN CONFORMANCE WITH ASTM A 90. 3. SEALANT: NONHARDENINGWATER- RESISTANT FIRE - RESISTIVE, COMPATIBLE WITH MATING MATERIALS; LIQUID USED ALONE OR WITH TAPE, OR HEAVY MASTIC. 4, HANGER ,ROD: STEEL, GALVANIZED; THREADED BOTH ENDS, THREADED ONE END, OR CONTINUOUSLY THREADED. 5 FABRICATE AND SUPPORT DUCTWORK IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS. PROVIDE DUCT MATERIAL, GAUGES, . REINFORCING, AND SEALING FOR OPERATING PRESSURES UP TO 2 INCHES W:G. 6: SEISMIC BRACING: PROVIDE LATERAL SUPPORT TO 11491BIT HORIZONTAL 'MOTION AND SWAY OF. DUCTWORK, 'COMPLY WITH SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD LEVEL B. 7. NEW DUCTWORK SHALL BE COVERED WITH INSULATION HAVING THE :FOLLOWING 'TR" VALUES: A. AIR DUCTS WITHIN CONDITIONED SPACE, WITH HVAC EQUIPMEN SUPPLY AIR TEMPERATURE LESS THAN 55. DEGREES F OR GREATER ;THAN 105 DEGREES 1 USE R -3.3. 8, THE CONTRACTOR, AS PART OR THIS CONTRACT, SHALL 'OBTAIN •' THE SERVICES OF A QUALIFIED AIR BALANCE: TESTING AGENCY. MINIMUM :QUALIFICATIONS FQR ACCEPTANCE SHALL BE THE GENERAL MEMBERSHIP STANDARDS OF THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR THE NATIONAL ENVIRONMENTAL AIR BALANCING BUREAU (NEBB). PROCEDURES, IN GENERAL, WILL BE IN ACCORDANCE WITH THE AABC "NATIONAL STANDARDS FOR FIELD MEASUREMENTS AND INSTRUMENTATION TOTAL SYSTEM BALANCE," VOLUME ONE, No 81266. FILE COPY 1_8060rstan9. that the Plan Check c, subject to ecxo and omissions and 0;.T.:;:' cf plans does not WWII Yiol2NOn otj 000 r�i� - -- adapted code at 08 c o a Gnn B lt cop0 0f +Ppeae4 sy „J, Date 2 - 3 -9tS 2M17 matN8Ma� -(X)05- - FLEXIBLE DUCT THERMOSTAT, WALL CEILING DIFFUSER CEILING RETURN GRILLE VOLUME DAMPER CONSTRUCTION NOTES: SMOKE DETECTOR, REF'. ELECTRICAL DWG. 2E112. `li "J �Llf;tli FEB 6 2 1_ 1 I p 2M10 1 2M11 2M14 2M15 KEY PLAN SCALE: NONE PROVED PROVED " - REDRAWN 09.16.97 12.1.97 REVISION APPROVED SUBTITLE FIRE PROTECTION PLAN BUILDING 21 -03.2 CURRENT REVISION SHEET 2M2 J OB NO DCA -9 -9 DWG N0. COMP NO 7 7 -4 i 2 1/2 0 , "6-0 7 -10. 2'1/ . ..1 2 1.1 2 11 4" 7 -0 - 7 -0 O.C. 7 -0 7 -0 . 7 -0 0.0. 7 -0 7 -0 7 -0 0:C. 720 7 -0 7 -0 0.C. 7 -0 7 -0 7 -0 O.C. 7 -0 6 -0 O.C. E/C 0/E - C/C E/0 C/E C/C E/C C/t 0 C/C , E/C C/E C/C E/C C/E E/C , I 2 "' 2 1/2 ' 2 1 2" 2 1 2". . 2 1/2 ° . 2 1 2" 2 1 2 2 1 2" 2 1 2" 2 1/2" 2 1 2" 2 1 2 2 1 2" 2 1 2" 2 1 '2 2 1/2" 2 1 2" 2 1/2 ". 0 o.c. ' 7 - 7 - 7 -0. -0, 7 - 7 - 0 7 - 0 00 . 7 - 7 -0 7 -0 o.c. 7- 0 7 -0 7 -0 oc 7=0 �° � -0 7 -0 oc 7 -0 6 -0 o E/C . c/E I E/C ' C/E C/C E/C C/E - - C/C E/C C/E C/C E/C C/E C/C E/C C/E E/C �I 2 1/2" to 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2' z 1/2" 2 1/2 " 2 1/2 4 -4' 7 -0 O.C. 7 -0 ? "- C/E C /C. 35 ® Q 32 31 30 29 28 27 2 1/2" 2 1 2" 2 1/2" 2 1/2 " 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1 / 2 -0 O.C. 7 -0 7 -0 7 -0 0.C. 7 -0 7 -0 7 -0 O.C., 7 -0 7 =0 . E/C• • C/E , E/C C/E 0/C E/C 0/6 C /C. _ - - PENDENT, 1/2" NPT, 4 w- 165'F W /6 "z6" h 40 SHEET METAL RUFFLE 43 (DEFLECTOR 1/2" BELOW OUCT BOTTOM I 1/2" 2 1/7 2 1 2" 2.1/2" 2 1/2" 2 1 2" TO SYST 7 -0 O.c. 7 -0 E/C C/E 7-0 6 -0 o c/c E/C PLUG ALL UPRIGHTS SUPPLIED MOM THIS MAIN 1/2" NPT, 165 BRZ UPRIGHT BELOW CEIUNG 1 .1 4,1 TO HOSE STATIONS 2 1/2' 2 1/2" 2 1/2" 2 1/2" 7-0 OC. 7 -0 7 -0 6-0 o 0/7 C/E C/C 2 1/2" ' 2 1/2" 2 1/2° 2 1/2° 7 -0 p.c. 7 -0 7 -0 6-0 0 E/C C/E C/C E/C 2 1/2° 2 1/2° 2 1/2" 2 1/2° 2 7 -0 0 c. 7 -0 7 -0 6-0 O. E/C C/E C/C E/C 1/2" NPT, 165'F BRZ -- UPRIGHT - • BELOW CEIUNG' (2) THIS UNE 2 1/2" 2 1/2 ° . 2 1/2 2 1/2 wi 1/2' 7 - 0 O.C. 7 -0 7 -0 6 -0 -0 C I. 6- E/c C/E C/C E/C •;iG C /C 2 1/2' 7- 2 1/2" 2 1/2" 2 1/2" 2 1/2" 21' 2 " 7 -D ". 7 -0 7 -0 6 -0 o.. 6 -0 c/c E/C C /E. 0/0 E/7 .I C/E . 2 1/2" 0600 AT 3' -4" B0D 7 5 1/2" BELOW 32 i G.L. BEAM II #1/ 14 AT -BEAMS 1. #2/ 2' -2" AT PURLINS 2 1/2 2 1/2" . 2 1/2° 2 1/2 12 1/2" 2 7J2 7 -0 6 -0 '0.c 6 -0 1 " -0 c/C C/C E /C C/E 7 - 0.c. 7 -0 7 -0 6 -0 o.c.' .6 -0 2 3 E/C C/E C/C - E/C ,. I c/ ,A2 . 1 2 NPT, 165'F B" UPRIGHT BELOW :. CEIUNG (4)- THIS UNE 2 1 2" i 7-10 '. �.w��� ®� / 2 1/2 2 1/2 2 1 2 21 _�i +r 1 2 1 2 2 -1 2" 2 1 2" 2 1/2 ,I' 2 1 2 2 -1 2 2 1 2" 2 1 2" ' 7-0 O.C. 7 C - 0 7-0 6 -0.0. 8 , E - C /C E / ' 3 \ ? - .O .C. 7J 7 0 , 0.C. C/0 7 -0 E-0 O.C.. C -0 / � % 21/2 ... 2 - .t/ '2.1/ / ] 7 +' 1 -ii CENTERUNE 40" - �/ `O ' BOTTOM OF DECK 1 • - -- - -_ - - - _ -•- - \ L r 2 1/2" - 2 1/2° 2 1/2 2 1/2° IQ 1/2" 1/2 1 2 2 1/2" 1 12 1/2 2 1/2 - ' 2 1/2" 2 1/2" 2 1/2" 2 1/2 1 2 2 1/2 2 1/2" 2 1 2 2 1/2" 2 1/2" -0 7 - 7 0 C 7 -0 7.0 7 -0 0•c. 7 0 7 -0 7 -0 /E C/C E/C C C/C E/C CIE C/C E/C 60 59 ® 57 56 55 54 53 ' 2 1/2" 2 1/2" 2 1/2" 2 1/2 2 1/2" e " 2 1/2 " 2 1/2" s2 1/2" 2 1/2" 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2 2 1/2" 2 1/2" \ 1 " 7 -0 7 -0 7 -0 0.c. 7 -0 7 -0 7 -0 0.c: 7 -0 7 -0. 7 -0 o 7 =0 7 -0 7 =0 0,7. 7 -0 7 -0 7 -0. 0.c. 7 -0 6 -0 o.c. 4 -6 C /E. 1 E/C C/E C/C E/C C/E C/C E/C C/E C/C E/c C/E C /C- E/C C/E E/C ' 2 1 / 2 " 1 T;1 -- _ . 7 -0 O.C. 7 -0 E/C C/E 7 -0 0.C. 7 0 7 -0 7 -0 0.C. 7 -0 7 -0 7 -0 '0.C. 7 -Q 6 -0 0.2 C/C E/C C/E C/C E/C C/E E/C 44 - - -- 0 -- -- T 46 - -- - .. _.... 0 . - - 0 - -- - - SD - -- -- 0 -- -- 52 2 1 / 2 " 2 1 /2" 2 1/2" 2 1/2" 2 1/2" 1 0.c. 7 -0 7 -0 7-0 _o.c. 7 - 0 - 6 - 0C. -A- CE - C/C E /C - C/E E/C 2 172' C/E C/ C 2 1 2" 2 1 2" 2 1/2" 2 1 2' 2 1 /2" 2 1 2" 2 1 2" 2 1 2" 2 1/2" 2 1/2 ". 2 1/2° 2 1/2 7 -0 7 0 o.c; 7 ` 0 7 0 7 0 .. 7 0. 7 -0 7 -0 o.C 7 -0 7 - 7 - O.C. 7-0 C/C - E/C . C/E C/C E/C C /E. 0/7 E/C - C/E C/C E/C - C/E , 2 1/2" 21 / 2 ° 2 1/2" 2 1/2' 1 -8 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2' 2 1/2" 2 1/2 7 - 7 - 0 7 - 0.0. 7 - 7 - 0 7 -0 Oc.' 7 -o 7 -0 7 -0 0.2. 7 0 7 -0 7 -0 0.c. 7 -0 7 -0 7 -0 0.c. 7 -0 6 -0 0.C. 7/E E/C C/E 'C /C E/C c/E C/C E/C C J � C /C E/C C/E C/C E/C C/E E/C �n 6 -0 0.c 4 -6 E/C 1 .. 1/2" NPT, 165E BRZ UPRIGHT 0E106 CEII ING 7 -0 o.c E/C c /E. 7 -0 SYSTEM #2 7 -10 ", PLUG' SSU THIS N c LINE TO 100L'.3 -- - - -- _ -- - -- - ` 2 1/i' 2 1 1 /2" 1 1 /2" e 1 1/4° o, 1 ' 3 6 -10 6 -10 9 -0 / 2 -3 4T. SYSTEM1 c 0 o.c. c 0 2 '1 2 2 1/2° 2 1/2" 2 1/2° 2 1/2" 2 1/2" . 2.1/2" 2 1/2" 2 1/2" 2 1)2" 2 1/2" 2 1/2" 2 1 /2" 2 1/2" 2 1/2" 2 1/2 7-0 "7 - . ' 7 - 0 O G 7 - 0 ' 7 -0 " 7 -0 o.c.a 7 -0 a "7 -0 " "7 -0 oc " C E 7 0 "7 -0 " 7 -0 o 7 -0 e e 7 -0 0C e 7 -0 C /E I - E/C C/E C/C E/C C/E C/C E/C C/C E/C C/E C/C E/C C/E 2 1/2" 2 1/2" 4x TO HOSE STATIONS SECOND FLOOR PLAN SCALE: 1/8 " =1' -0" 12 • Kr-J>. 10 9O Q 1/2 2 1/2" 2 1/2" 2 1/2° 2 1/2' 2 -.. - - �}i -- 2 1/2" 2 1/2" 2 1/2" 2 1/2 ACCEPTABILITY THIS DES166 AND /0R SPECIFICATION IS APPROVED - APPROVED 'BY ® ® 0 DEPT. DATE 2 1/2 1 - 0� 2 5X2 MT 6 -0 -0. 2 " E/C i l 21 4 2711 - 0" 2 1 2" 2 1 2" l 2 1/2° 21 2 1 2 2 2 1/ 2 1 2" 2 1 2" 2 1/2 2" 2 1 2" 2 1'2" 2 1 2" 2 1/2" 2 1 2" 2 1 2" 2 1/2" 2 1/2" 2 1/2" "' 4 o.c. „ o.c. o 7-0 7 -0 0.c. 7-0 7-0 7 -0 o.c. 7 7 -0 7 -0 o.c ' 0 7-0 7-0 o.c. 7 - 0 6 - 0. 0.C. - , C/E C/C E/C 'I C/E E - C /E - /C - '.: /C - C/E C /C . E/C C/�E - C/C E/C C /E C/C E/C 7/E E/C \ 1X,, j 2 1/2" III 1 -8.: w . II STUB'UP 1x0 -8 1" PLUG (TYP) 11 I' TO 212T SSU 1/2" (790) 2 1/2° 2 1/2" 2 1/2" 2 1/2" 1/2 I 2 1/2" ! 2 1/2" 2 1/2" 2 1/2" 2'1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1 /2 1_e °\ 7 -0- 7 -0 o.c. 7 -0 7 -0 7 -0 7 0C. 7 0 7 -0 7 -0 o.c. 7 -0 7 -0 o.c. 7 -0 . C/C 0/7 - E/7 C/E .0 /C E/C E/C • • C/E INSPECTION CONNECTION LEGEND: • CENTRAL (JD "A" BRASS UPRIGHT 17/32" BELOW GW h CEIUNG AT ROOF- PURLINS UPRIGHT SPRINKLER ABOVE GWB CEIUNG o PENDENT, `` 1 '' 65' UNLESS OTHERWISE NOTED 1" PLUGGE OPENING 906 FUTURE PENDENTS RIGID COUFH1lll1NG - - - 4 CENTRAL M -ID' H" BRASS HORZ 010706LL 1/2 ' 0.C. OUTLET C0 PLNG (2 1/2 "x3 /4 ") E/C END OF PI 'E TO CENTER OF OUTLET C/C CENTER OF OUTLET TO CENTER OUTLET C/E CENTER OF OUTLET TO CENTER OF .PIPE GENERAL NOTES 4. SLOPE ALL PIPING AS TO RISER OR TO LOW 7. CONNECT TO EXISTING INDICATED ONLY AFTER FOR 24 HOURS). HAS BY THE BOEING ARE 1 1. NOTIFY BOEING FIRE TO SHUTDOWN. 2. FOR EARTHQUAKE BRAOING USE 1" STEEL PIPE FOR BRACES UP TO 7r 0" LONG & 1 1/4" PIPE FOR BRACES 7' -1" T 9 LONG. FLATTEN & DRILL ENDS FOR M )UNTING. ITED, UNLESS OTHERWISE EPARTMENT 24 HOURS PRIOR 3 USE 1/2" -165' SPRINKLER- HEADS (PENDENT OR UPRIGHT AS INDIC• NOTED). NDICATED TO DRAIN BACK POINT DRAIN. 5. ALL MATERIALS & INSTALLATION SHALL CONFORM TO NFPA PAMPHET 13 FOR ORDIIIWRY HAZARD OCCUPANCY. 6. FOR REFLECTED CEILIN) PLAN, SEE DWG N0. CROSSMAINS WHERE HYDROTATIC TEST (200 P51 - EEN WITNESSED & APPROVED EPARTMENT. A AA 11. NEW 506190116 HEAD" SHALL BE PENDANT TY CHROME FINISH. M REMOVE EXISTING PENL BRANCH PIPE TO SUS ° NEW PENDANT SPRINKL AT SUSPENDED CEILING E, 165 DEGREE RATING, OTES: ANT SPRINKLER HEAD, Er ENDED .CEILING AND =R HEAD. REMOVE EXISTING UPRI HT SPRINKLER HEAD, EXTEND BRANCH PIPE TO SUS NDED CEILING AND INSTALL NEW PENDANT SPRINK R HEAD. 8. SYSTEM #1: HANG UN $S AT 7" BELOW 6x16 PURLINS W /14" U- HONKS, - MAIN HANGERS AS NOTED. 9. SYSTEM #2: LINES AT 7 "'BELOW 6x16 PURUNS COL H-1, & P -U HUN W/14" U- HOOKS, ONES AT 10" BELOW PURUN" ® COL 1 -0 HUNG W/16" U- HOOKS:, 10. SEE SECTION M2M202,M2 CONSTRUCTION 2M266 2M26, 2M267 2M26 SCALE NONE FOR BLDG SECTION.. KEY P AN ChY 2M263 CITY OF TUKWI AN 1 6 19 SYM I '.; REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE - - REDRAWN. KB SB 09.16.97 I A ' OFFICE AREA 2 -03.2, MEZZ DCA -9 -97039 RICE 12 1.97 SEQUENCE OF . ?E HA lUrsi /AC SYSTEM, ACU -1, ;ACU -2:. - A. GENERAL: , 1. - SYSTEM PROVIDES HEATING, COALING, VENTILATION, AND SPACE PRESSURIZATION.• B. SYSTEM START /STOP: .. . 1 PROGRAMMED SCHEDUUNG 'AIR CONDITIONING COIL UNITS ARE OPTIMALLY STARTED AND STOPPED BASED UPON TIME CLOCK. ,PROGRAMMED OCCUPIED AND UNOCCUPIED. TIMES, WITH WEEKDAY, WEEKEND AND HOLIDAY SCHEDULES. 2. WHEN - SHUT - DOWN' OF.A1R.' CONDITIONING UNITS OCCUR,' THE OUTDOOR AIR. DAMPERS. AND. AIR VALVES SHALL BE IN THE CLOSED POSITION. MINIMUM OUTDOOR AIR; OUTSIDE AIR . FLOW MAINTAINED AT A CONSTANT VALUE BY OPERATION - OF A MINIMUM . P05510N SWITCH •(ADJUSTABLE). _ - THE BUILDING VACS SHALL CONTROL THE HEATING AND COOLING COILS AND FANS TO MAINTAIN' THE ROOM TEMPERATURE SETPOINT AT 72 DEGREES F DURING OCCUPIED AND. WART -UP MODE AND 55 DEGREES F, (HEA1155), 90 DEGREES F (COOLING) DURING UNOCCUPIED 'MODE. SMOKE DETECTORS PROVIDED BY ELECTRICAL' SHU' DOWN AIR CONDITIONING UNITS IF SMOKE IS DETECTED. VAV TERMINAL' UNIT. (ACT - 2 ONLY): 1. ON. CALL FOR COOLING FROM TEMPERATURE TRANSMITTER IN CONFERENCE ROOM, UDC CONTROLLER MODULATES AR VALVE OPEN TO MAXIMUM DESIGN CFM TO MAINTAIN COOLING SETPOINT. ON DROP IN CONFERENCE ROOM SPACE TEMPERATURE, AR VALVE MODULATES TO MINIMUM DESIGN CFM. - - ALL TEMPERATURE CONTROLS SHALL BE BARBER /COLMAN. POINT OF CONNECTION TO EXISTING, CMCS IS APPROX. 100 LF. AIR ECONOMIZERS. SHALL. BE CAPABLE OF PROVIDING- PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING. LOAD. CONTROLS SHALL .NOT PRECLUDE THE ECONOMIZER FROM OPERATION. WHEN MECHANICAL COOLING IS REQUIRED. AIR - ECONOMIZERS SHALL BE CONTROLLED BY A SYSTEM CAPABLE. OF DETERMINING IF OUTSIDE AIR CAN MEET ALL OR PART OF ALL THE RESPECTIVE SYSTEM COOLING LOAD. CONTROL SIGNAL FROM BUILDING CMCS BY CONTROLS CONTRACTOR, I ACU =1 FIELD. INSTALLED CIRCUIT 800D- GAS.HTR. AIRFLOW AND.: CONTROL .DIAGRAM ACU -1 CONTROL SIGNAL FROM BUILDING CMCS BY CONTROLS CONTRACTOR - - ' I.ACU -2 FIELD INSTALLED CIRCUIT BOARD GAS HTR, J OFFICE AREA NOT TO SCALE • .AIRFLOW. AND` CONTROL DIAGRAM ACU -2 NOT TO SCALE ce WAG' SYMBOLS ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. OFFICE' AREA DATE bi±yLl fl 2M12 M310 RA �- CONF. RM. 2M12 M310 TITLE Mqb MECHANICAL MASTER CONTROL DIAGRAMS BUILDING 21 -03.R TEMPERATURE TRANSMITTER CURRENT RELAY SD SMOKE- DETECTOR CORP. PARK � Ir •� V CURRENT REVISION SHEET JOB NO D NO SYMBOL g T 10 DCA -9 97039 COMP NO. 21- 03- RFM310 FiECENED CITYOFTUKWILA JAN 1 6 1996 PERMIT (1FNTFR DATE SYM I REVISION Y APPROVED DATE SYM REVISION BY. APPROVED DATE I - I- REDRAWN KB SB 09.16.97 A , i n FTCE-AREA 21 -032, MEZZ. DCA -9 -97039 - RICE 12.1.97 - I I r% El A %I•■ MEIN r NO4B MO4 rt 'LO4A EF NO4A 2" PLUMBING VENT LSS 4V/48 p e ilp 1 i la N_ INTAKE HOOD t f.; PO4 %A...0 B - -- FLEX AH R04� 1 SUPPORT FRAME 48/ a ' PAINT BOOTH 1 I II gin ® • !I RS9 u1• I 34/34 AH SO48 030/3 PLUMBING VENTS olUis GAS CONNECTIO SEE DETAIL 4 TYPICAL RFM450 M500 /48 S03 4 3/4 PIPE SEE DETAIL TYPICAL RFM450 1 M500 ANCHOR 4 ": PLUMBING VENT tp3 1 1/2" LfL0034 H ft 2A f. (. Tr - • PARTIAL ROOF PLAN e- k SCALE: 1/16 "= 1' -0 ° r <'3;Y e 2" PLUMBING VENT 2750 CFM SY 2" PLUMBING VENT --- T03A 4000 CAM EXH BLUE -M OVEN , VENT - (2)' 2" PLUMBING VENT 1'2 RU3A 100 18 GA GALV - _ - - -_- EF RU3A 240 20 GA, GALV DUCT 0 2" PLUMBING VENT PACE #U -24F UTILITY FAN SET 3100 CFM @1.5 ESP EQUIP #EFRUTA 2" PLUMBING VENT T ACCEPTABILITY THIS DESIGN ANO /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DAIS CHECKED APPROVED APPROVED SUBTITLE HVAC ROOF PLAN c CORP.PARK N\q 0006 BUILDING 21 -03.R MECHANICAL MASTER COL. H -U 1 - G - NATURAL \S P cp _ ❑M1I � vuv_ POINT OF ;ONNECI a® •N04 Ail RTO4A m CT NO3 AHU m WAS AH 225 RJO4A RAL NO AS GEN RAL NO r 1 '7 • ( TRANS D YC0090D4LC 90 MBH T 3000, CFM, 1.25 -ESP. T 120 MBH 2 STAGE HEA 81% AFUE, 3.00 EER, ECONOMIZER, POWER E INTERFACE, 460V/3PH, GEN RU3A RU3A RP2A RLO2A WAS WAS WAS WAS WAS F1� WAS ) WAS ) nn� WAS WAS CONSTRUCTIO J NOT KEY SCALE ) VNF LOW TAL - CAf 2 HP INPUT DUAL C( -IAUST, 22.0 PLAN NONE .� ,e7,777.77- � 21 - ON AS ROOF UNIT MODEL 70 MBH SENS. CAP., ERSIZEF a MOTOR, 97 MIT/ HEAT OUTPUT, PRESSOR,' DOWNFLOW ONVENTIONAL THERMOSTAT A.. ) = 0 DATE )3- RFM450 OMP NO RECEIVED CITY OF TUKWILA JAN 161996 PERMIT CENTER 1 APPROVED REVISION APPROVED ACCEPTABILITY THIS DESIGN AND /OR SPECIfICAT1ON IS APPROVED APPROVED BY SUBTITLE DETAILS LAY— I CEILIP SYMBOL Y NO COMP NO. DCA 9 -97039 c na 21- 03 -M500 UNION TYPICAL G > GAS `PIPE GAS CON NECTI O \ TO NO SCALE PRESSURE REGULATOR, 240 CFH, INLET PRESSURE 5 PS1, OUTLET PRESSURE 10 INCHES OF WATER. DRIP LEG - J �IIIIIIiIIIIIIl FLEX PIPE VAC U \IT HVAC UNIT (TYPICAL) =TA RFM450 ( M500 SHEET, METAL CAP SEAL WITH ELASTOMERIC SEALANT GAS P NO SCALE P MECHANICAL MASTER NO SCALE LINED DUCT RE TURN GR LL UNIT BOLT CEILING GRILLE TYPICAL D NUT & WASHER 1" NEOPRENE PAD STEEL BEAM R000TOP UN T SUPPORT DiTA NO SCALE NG SUPPORT AT R00= BUILDING 21 -03 f A GAS PIPIN3 L REM CORP. PARK RETURN PLENUM.- M500 2 HOLE PIPE STRA (1 SIZE LARGER THAN PIPE) .IR N 0 4x6 TREATEDNOD BY GENER L CONTRA TOR RECEIVED CITY OF TUKWILA JAN 1 6 1998 PERMIT CENTER if - II S 1' -0" MIN. TO EXIST. ADJACENT PURLIN � EXIST. 12x12 DF 1 COL. 1 ' 1 GLB I EXIST. I I TS 4x4X3/16 — EXIST. 12x12 DF 1 COL. # EXIST. 9x29 1/4 %I � COLUMN, BELOW I EXIST. 9x37 3/8 GLB r – 1 I I EXIST. 7x34 1/8 GLB I 1 12 2x2A U ■ I LOCATIONS OF 1 1 i L4x4x1/4 x +1 EXIST. 6 "4 PIPE – BELOW EXIST. ROOF STRUCTUR 0' -6" CONNECTORS (nP) EXIST. TYP. PANELIZED ROOF 1/2" PLYWOOD CDX 32/16 "oc 2x4 @ 24 DF #2 L4x4x1/ Q ADD 2x4 SUB – PURLIN ! S to ° iiR p?x ■ MAX WEIGHT OF c UNIT = 100 lb - HVAC UNITS INSTALLED ON W12 FRAME PER MECHANICAL DRAWINGS to ,_ M I N PER 'ti; o 4 ,,,,,, IF B ,r L4x4x1/ (2 TOTAL) EXIST. EXIST. 12x12 TS 4x4X3/16 COLUMN EXIST. 12x12 / DF #1 COL. EXIST. 9x29 1/4 GLB DF #1 COL. 1 BELOW EXIST. 7x34 1/8 GLB L W12x26i LJ I r 2' -7i t 181 I c VERIFY FRAME WIDTH TO SUPPORT UNIT BASE WITH HVAC c, `.- L4x4x1/4 6 4111:1111_ ®® UNIT SUPPLIER --S N ADD 2x4 SUB – PURLIN c. PER • -----1-------__ ® O l bs E '"� MAX WEIGHT _ UNIT – 1000 DUCT PENETRATIONS THRU OPENING ROOF PER ARCH. DWGS. r HVAC UNITS INSTALLED ALIGN DUCTS TO AVOID ,I's ON W12 FRAME EXIST. 2x4 SUB – PURLINS PER DRAWINGS Al MECHANICAL (PCP.) S L4x4x1 /4 (2 TOTAL) r EXIST. 12x12 DF #1 COL. XIST. 9x 37 3/8 GLB EXIST. 12x12 DF #1 COL. 4 "4 STD. (6 TOTAL) PIPE LW12x26 1 EXIST. 7x34 1/8 GLB EXIST. 9(29 1/4 a ` r. f EXIST. 16 I TS 4x4X3 COLUMN BELOW STM ORIG. REVISION OFFICE AREA 21 - 03.2 MEZZANINE BY JHR APPROVED DATE 12/22/97 SYM 60' -0" PARTIAL ROOF FRAMING PLAN 0 SCALE 1/4 " =1' -0" REVISION BY APPROVED DATE NOTE: SEE MECHANICAL DRAWINGS FOR LOCATION OF HVAC UNITS AND ROOF PENETRATIONS. DO NOT CUT EXISTING 2x4 SUB – PURLINS. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY 0 DRAWN ' 12 99 22 SUM. KJT 97 GENERAL STRUCTURA (The following apply unless shown otherw CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION S SPECIFICATIONS, AND THE UNIFORM BUILDING CODE (1994 EDI 2. DESIGN LOADING CRITERIA ROOF LIVE LOAD (EXISTING) 25 PSF MECHANICAL UNITS WEIGHTS FURNISHED BY MANUFACTURER 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AN I CONDITIONNS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONS RUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE S RUCTURE AN STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE ITH THE PLANS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND TiE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND /OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND /OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS 0 ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORR CT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF T1 OWNER, CONTRACTORS, OR OTHE'l ENTITIES tR PERSONS AT THE PROJECT SITE. 7. CONTRACTOR– INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO TH': ARCHITECIT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTR CTION. 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. HERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY TH'- ARCHITECT AND THE STRUCTURAL ENGINEER. STEEL 9. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHA I1 BE BASED ON THE LAITEST EDITIONS OF THE A.I.S.C. SPECIFICATIONS AND CODES: 1. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS – ALLOWABLE' STRESS DESIGN. 2. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, A ENDED BY THE DELETION OF THE FOLLOWING SENTENCE IN PARAGRAPH 4.2.1: "THIS APPROVAL CONSTI JTES THE OWNER'S ACCEPTANCE OF ALL RESPONSIBILITY FOR THE DESIGN ADEQUACY OF ANY DETAIL CONFIGURATION OF CONNECTIONS DEVELOPED BY THE FABRICATOR AS PART OF HIS PREPAR1TI0N OF THESE SHOP DRAWINGS." 10. STRUCTURAL STEEL, INCLUDING PLATES, PIPES AND ROLLED S APES, SHA CONFORM TO ASTM A36, Fy = 36 KSI. CONNECTION BOLTS SHALL CONFORM TO ASTM A307. 11. ALL A307 CONNECTION BOLTS SHALL BE INSTALLED TO THE S UG –TIGHT C)NDITION PER UBC 2° :. , IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED 'ECOMMENDA IONS. 12. ALL STEEL SHALL BE HOT– DIPPED GALVANIZED. ALL FIELD WELDED AREAS SHALL BE TOUCHED UP WITH ZINC –RICH PAINT (GALVACON OR EQUIVALENT). PARTIAL ROOF FRAMING PLAN BUILDING 21 -03.RF OFFICE AREA 21 -03.2 MEZZANINE STRUCTURAL MASTER COL. 1- 4.5 /H –N CORP. PART{ L NOTES se on the pI ALL CONFOR A TO THE DRAWINGS, [ION). ms) FED J,1 RECEIVED CITY OF TUKWILA J AN 2 3;1598 PERMIT CENTER COMP NO. KA -91-97039 21- 03– RFS162 21- 03- RFS182 REFER TO INFORMATION / AT RIGHT FOR CONN. CUT AND PATCH ROOF AND PLYWOOD SHEATHING AT PIPE COLUMN CONN. SECTION SCALE: 3/4" = 1' -0" IL 4x4x1/4 x 0' -6" (6 TOTAL 1/4 "x6 "x1' -0" CONN. 12 PLATE BEHIND EXIST. 6x16 PURLINS EXIST 3/4" GYP. BOARD CEILING — EXIST. 7x34 1/8 GLB SECTION W12 - PLAN VIEW TYP. /16 V 1 w 12x26 1 BEAM PL 1/ 2 "x8 "x1' -O" (6 TOTAL) EXIST. 1/2" PLYWOOD ' EXIST. 2x4 SUB - PURLINS y 1/2" CLR. -- COL. CAP PLATE 1 /2 "x8 "x1' -0" 1/4 1/4V ( 4 "4 STD. PIPE (TYP.) 1/4V (TIP. 7 1/2" BENT PL. 1/4"x 10"1 110" x 0' -9" LONG w/ (4)3/4 "0 A307 THRUBOLTS SPACE BOLTS 6" APART HORIZ. \— EXIST 3/4" GYP. BOARD CEILING EXIST. 7x34 1/8 GLB STRUCTURAL FRAME CAULK WITH ELASTOMERIC SEALANT DRAW BAND WATERTIGHT UMBRELLA NAIL PRE - FORMED FLASHING BOOT (COMPATIBLE WITH EXIST. ROOFING MATERIAL) TO WOOD NAILER - FLANGE SET IN MASTIC OVER ROOFING - PRIME FLANGE BEFORE STRIPPING. SEE ARCH. DWGS. FOR FLASHING INFORMATION. CONNECTION PER A /S2 EXIST. GLULAM BEAM W12 6 6 r W12x26 BEAM EXIST. TS COLUMN BEYOND ANGLE TO BM FLANGE SECTION SCALE: 1 1/2" = 1' -0" / i /j / // / ...-"; \ ..../ / % / W12 PER PLAN DATE SUBRRE 12 MECH. UNIT BUILDING 21 -03.RF EXIST. 2x4 SUB - PURLIN FRAMING DETAILS PLAN SCALE: 3/4" = 1' -0" OFFICE AREA 21 -03.2 MEZZANINE STRUCTURAL MASTER COL, 1- 4,5 /H -N CORP, PARK NOTES: 1. ALL STEEL GALVANIZED 2. PAINT ALL STEEL FRAMING GRAY TO MATCH EXISTING. NEW DUCT OPENING OR. . 12/22/97 - ___ ____MO _ ______ MI MEI ME NM M MI= — MI ui PROVED al OFncE AREA 21-03.2 MEZZANINE REV63N B! APPROVED SYM REVISION BY APPROVED 2 -01 -97 ACCEPTABILITY KJT THIS DESIGN AND /OR SPECIRC 110N IS APPROVED 97 TEMS SHALL BE ADD 2x4 ADJACENT TO EXIST. 2x4 WITH 12d NAILS • 16 "oc ANC A35 CLIPS AT EACH END TO 6x16 PURLINS CUP.REN'' It " ON DCAF - 9 1 - 97039 � T F FS162 RECEIVED CITYCFTUKWILA IAN 2 3 1ST3 A ERA , T CENTER ., DMP N2 PCA-9-9703g 1- 03 -P`' N0' 03- RFS162 D� D VICINITY MAP 7 -127 KING COUNTY CBVIER (FAA) 99 FROM SEATTLE — TACOMA AIRPORT DEVELOPMENTAL CENTER EST MARGINAL WAY CORPORATE PARK FROM DOWNTOWN SEATTLE 599 TUKWILA co 900 FROM KENT\ & AUBURN 157 \\ 0 NO SCALE 900 3 D U L MMA 35 TO 21 AREA MAP 21 -02 BLDG. 21 -03 ADDRESS 3417 SO. 120TH PLACE SEATTLE, WA (EAST MARGINAL WAY CORPORATE PARK) 21 -03 7 21 -05 PROJECT SITE 21 -01 0 EAST MARGINAL WAY CORPORATE PARK O NO SCALE ACT A \D NG 2'413 -03 (MICA-9470M BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BLDG. 9 -51.2 COL N /1, AFTER COMPLEFICd OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX ® THESE DRAWINGS CONFORM TO THE 1994 U.B.C., U.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 —A. • BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER GENERAL NOTES OF PRINTS REQUIRED FOR PERMIT PACKAGE: 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS 1st 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 2. TENANT IMPROVEMENT (NON — STRUCTURAL): ❑ 4 SETS OF ARCHITECTURAL JRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. MECHANICAL, 5 COMPLETE SETS. ❑ 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: CONVERT EXISTING STORAGE SPACE INTO OFFICE AREA 21 -03 —A1 21- 03 -2A01 21 -03 -2412 21 -03 -24281 21- 03 —A505 21- 03 —A506 21- 03 -2E12R 21- 03 -2E12 21 -03 -2E62 21- 03 -2E112 21 -03 -2812 21 -03 -28112 21 -03 -28262 21- 03— RFM450 21- 03 —M500 DRAWING NUMBER 21- 03 —R1S -162 LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS SHEET NUMBER 91 2401 2412 24281 A505 4506 2E12R 2E12 2E62 2E112 2812 29112 28262 RFM450 500 RES -162 BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION EXTERIOR NON— BEARING WALL STRUCTURAL FRAME ROOF SEISMIC ZONE WIND LOAD SNOW LOAD DRAWING INDE TITLE SHEET EXITING PLAN FLOOR PLAN REFLECTED CEIUNG PLAN DETAILS SECTIONS LIGHTING REMOVAL LIGHTING 208Y/120V POWER 4809 POWER HVAC PLAN PLUMBING PLAN FIRE PROTECTION PLAN HVAC ROOF PLAN DETAILS TITLE ROOF FRAMING PLAN CODE SUMMAR`r X AREA /EXIT CALCULATIONS 1ST FLOOR TOTAL: 38,000 SF OFFICE: 21,438 SF /100 = 215 OCCUPANTS COMPUTER ROOM: 12,318 SF /300 = 41 OCCUPA OT0 TOTAL: 258 OCCUPANTS 2ND FLOOR TOTAL: 38,000 SF OFFICE: 32,847 SF /100 = 327 OCCUPANT STORAGE: 1,020 SF /300 = 4 OCCUPANT TOTAL: 331 OCCUPANTS GRAND TOTAL: 587 OCCUPANTS /50 = 11.74 LF REQ 12.00 LF PROVIDED EXIT WIDTH SYM A B MMA 35 TO 21 -03 MMA 35 TO 21 -03 REVISION 4160129 -00 J#160129-00 0Y G9M JRB APPROVED DATE 11.05.97 11/11/97 REVISION APPROVED SYM BY DATE L eM P L I SFAW 6 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE J.REPASS CHECKED DRAWN B. LOOMIS CHECKED ENGINEER DATE SUBTITLE 12 -1 -97 12 -1 -97 TITLE SHEET APPROVED APPROVED TITLE BUILDING 21 -03 ARCHITECTURAL MASTER COL. TUKWILA 1994 U.B.C., U.F.C., IJ.P.C., WASH NGTON STATE ENERGY CODE AND THE WAC 51 -20 AS ADAPTE' OR AMENDED BY LOCAL ORDINANCES AND CO PLPANCE WIl -I CITY OF TUKWILA ZONING GROUP B (OFFICE) AND 5 -1 (ST. RAGE) TYPE V —N (SPRINKLERED) 236,530 SF 256,948 SF 30' -6" 2 1,274 BARRIER FREE SPRINKLERED UNPROTECTED 1 —HOUR AT OFFICE; 1 —HOUR AT OFFICE; 3 80 MPH EXPOSURE 25 PSF IIFIED RXIT WIDTH V —N AT W REHOUSE AREA V —N AT W REHOUSE AREA C c IE C URRENT Rc DCA-9 -97039 SHEEG DWG ND. REVISION N59BER DATE 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 12 -1 -97 RECEIVED CITY OF TUKWI JAN 1 1998 PEF1 DATE 12 -1 -97 SYMBOL ;SIGN Al 1CA -9 -97039 21 -03 —Ai COMP NO. Olt OM NI OPEN OFFICE CD 6 SECOND FLOOR PLAN SCALE: 1" = 30' SYM A RELOCATE ENG. CONF. RM. REVISION 167020 -00 13 OFFICE AREA 21 -03.2 DCA -9 -97039 BY MRM BLL /JKR APPROVED SYM REVISION BY APPROVED DATE 5 -09 -96 12 -1 -97 DAZE gLASWE'ArAft ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DATE 12 -1 -97 12 -1 -97 SUBTITLE TITLE ARCHITECTURAL MASTER SECOND FLOOR PLAN BUILDING 21 -03.2 COL. ALL CORPORATE PARK DRAWN B. LOOMIS CHECKED ENGINEER J. REPASS CHECKED APPROVED APPROVED CURREN SHEET JOB NC DWG NI LEGEND: F — EXIT RATHWAY GENERAL NOTES: M9B - 0 off ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES DISPOSE OF ALL SURPLUS MATERIALS AT THE DIRECTION OF BOEING CONSTRUCTION MANAGEMENT PERSONNEL CON RACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHAL CO- ORDINATE THE WORK OF ALL TRADES REQUIRED TO COMPLETE THE WORK. AFTER COMPLETION OF CONSTRUCTION, PATCH, REPAIR, AND PAINT THE ADJACENT SURFACES TO MAT 1-1 EXISTING CONDITIONS. flM6toos RECEIVED CITY OF TUKWILA JAN 1 S 1990 Pawn T REV SIGN SYMBOL A 2A01 DCA -9 -97039 DATE 12 -1 -97 COMP N0. 21- 03 -2A01 \\ OPEN TO FIRST FLOOR i1 A 2Al2 A506 fr fr B 121A506 v VISIBILITY ROOM OCCUPANCY = 3 AREA = 320 SF OPEN OFFICE AREA OCCUPANCY = 44 (B OCCUPANCY) AREA = 4,462 SF ELECT. EQUIPT. DRINKING FOUNTAIN 1 / 8 " = 1' - 0" A 2Al2LA506 REVISION OFFICE AREA 21 -03.2 J #DCA -9 -97039 12 -1 -97 DRAWN B. LOOMIS CHECKED APPROVED APPROVED 12 - 1 - 97 REVISION el LowErAfraw. � ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY 12 -1 -97 SECOND FLOOR PLAN 3MEET ENSIGN 12 -1 -97 FLOOR PLAN OPEN TO 0RST FLOOR TITLE ARCHITECTURAL MASTER 'PRO IDE AN INSTALL NEW SUSPENDED CEILING ;SYSTEM. G'ID SYSTEM SHALL BE 24" x 48" 30 IN DXL SERIES". INSTALL PER MANUF'S 00 414\ 1om`'; e '_INST2UCTIONS AND PROVIDE STANDARD SEISMIC ^N '1 ' 2A%e BRACING AT 12' 0" O.C.E.W. (REFER DETAILS). ALL ; CEIL NG TILES SHALL BE 5/8" "ARMSTRONG #895 ", INSTALL N CEILING AT THE HEIGHT OF 2" ABOVE :TOP OF EXISTING MOTION UtIRCIURS. (APPROX. ` ..LO' ;0 ABOVE FINISH FLOOR - 1 '�RIFY EXACT HEIGHT). BUILDING 21 -03.2 COL. 1- 4.5 /H -N CORP. PARK ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABL: CODES. DISPOSE OF ALL SURPLUS MATERIALS AT THE DIREC ION OF BOEING CONSTRUCTION MANAGEMENT PERSONNEL, LUIN RACTOR SHALL VERIFY ALL EXISTING CONDITIONS I PRIOR PTO THE START OF CONSTRUCTION. O CONTRACTOR SHAL CO- ORDINATE THE WORK OF ALL TRADES REQUIRED TO COM LETE THE WORK. AFTER COMPLETION OF CONSTRUCTION, PA CH, REPAIR, AND PAINT THE ADJACENT SURFACES TO MAT 'H EXISTING CONDITIONS. GENERAL NOTES: Citik QONSTRUCTI NOTES PATCH /REPA�R ALL EXISTING GYPSUM BOARD WALLS COL. FURR- UTS, ETC. TO PREPARE THEM TO RECEIVE NEW PAINT. QAINT 1 COAT PRIMER & 1 COAT FINISH, "BDC -1 ", S MI -GLOSS LATEX. EXTEND PAIN • 4' ABOVE SUSPENDED CEILING HT. PROVIDE AND INSTALL NEB, 4" VINYL BASE, COLOR SELE;TED Bl BOEING. ERECT FULL HT. WALL (FROM FLOOR TO UNDERSIDE OF :XISTING DECK ABOVE) OF 5/8" TYPE -X GYP. BD. SNCH SIDE OF 3 1/2" MTL. STUDS (20 CA.) AT 16" D.C. (PINT PER NOTE Al) WITH FULL -THICK ACO STIC B TT INSULATION. TAPE AND S L ALL WALL PENETRATIONS BY DUCTS, CON UITS, ETC. PRO IDE AN INSTALL NEW 3' -0" X 7' -0" S.C. WOOD DOOR AND I.M. FRAME. HARDWARE: LATCHSET - YALE AUGUSTA #AU5401L x 1210 CYLINDER, US26D KEYED BY TOEING LOCK AND KEY. HINGES - HAGER 1 1)'2 PAIR #BB1279, 4 1/2" x 4 1/2" US26D, - CLO ER ALE #PA403 x`LSBX x SNB, PAINT DOOR 3325 BY PRESERVATIVE PAINT. ri Ex911O: fA 1Y PAINT COLU N IDENTIFICATION NUMBERS PER BOEING STA IDARDS, EACH COLUMN. INSTALL "ORIANIZATION SIGNS" PER BOEING STANDARDS NT EACH ENTRY DOOR, 5' -0" A.F.F. REMOVE EXI TING GYPSUM BOARD ON WALL TO INSTALL CONDENSATE DRAIN AND INSTALL NEW GYPSUM BO RD AFTER INSTALLATION. (SEE PAINT INFORMATION IN NOTE Al ABOVE. 2A17 2014 2015 EY PLAN 2Al2 2013 ' QFTU 2 0N 16 1998 )CA - 9 - 97039 COMP ND 21- 03 -2Al2 O. \21- 03 \2Al2DWC FACIUIIES 8/4/1942 9:48 AIL i 111 III l I II I I OPEN TO FIRST FLOOR I MI ■Y • ■Y;■^r■Y■ TT IIIg_•1 • El INN : -•= : ��•i Y■ vtain imenT O ■Y� ■i� / ■Y ■■ ; . Ipi r 1.4 • ■ • IM • ■ ' ■ A ra r. 0 III EXISTING 2 -HR. WALL SYM A REVISION OFFICE AREA 21 -03.2 J ;Y DCA -9 -97039 BY BLL /JKR APPROVED DATE 12 - 1 - 97 SYM REVISION 262811 A506 EXISTING 2 -HR. WALL FULL HEIGHT WALLS MAIN RUNNERS IN THIS DIRECTION REFLECTED CEILING PLAN (=, 1 / 8 " = 1 ' - 0 " BY APPROVED DATE OPEN TO FIRST FLOOR ACCEPTABILITY ,AWN LOOM: ECREO SP:. .CATION IS APPROVED APPRC D BY DEPT. DATE I �A$` > DESIGN AND /OR O RETURN AIR GRILLE 2X4 FLU RESCE4T LIGHT FIXTURE AIR SUP'LY DATE 12 -1 -97 12 -1 -97 Mq SUBTITLE REFLECTED CEILING PLAN TITLE BUILDING 21 -03.2 CURRE SHEET JOB N LEGEND • SPR I NKL :R HEAP CONSTRUCTION NOTES PROVIDE AND INSTILL NEM1 SUSPENDED CEILING SYSTEM. GRID SYSTEM SHALL BE 24" x 43" "DONN DXL SERIE• ". INSTALL PER MANUF'S INSTRUCTIONS AND P.ROVI E STANDARD SEISMIC BRACING AT 12' -0' O.C.E W. (REFER DETAILS). ALL CEILING TILES SHALL BE 5/8" "ARMSTRONG #895, INSTALL NEW CEILING AT '�HE HEIGHT OF 2" ABOVE TOP OF EXISTING MOTION DETECTORS. (APPROX. 10' -0" ABOVE FIN. FL. -!, VERIFY EXACT HEIGHT). NOTE: CEILING H -. AT CONFERENCE ROOM TO BE 9' -0" ABOVE =WISH F 2616 2017 r 2615 I'CEY PLAN L 2613 0 e RECEIVED CITY OF TUKWILA JAN I 1993 PERMIT CENTER PROVIDE CLEARANCE AT OPPOSITE WALLS, (NOT ATTACHED). ATTACHED AT STARTING AND ONE ADJACENT WALL CEILING GRID AT WALL - SECTION (TYP) SCALE: NONE STRUT - SECTION (TYP) (1- 1 SCALE 3'= 1' -0" #12 GA. HANGER WIRE, TYP. 3 TURNS, MINIMUM (1) #10 x 1" SELF TAPPING SCREW EXISTING 2 X _ WOOD JOISTS EXISTING 5/8" GYP, BD. (TAPED AND SPACKLED) VERTICAL COMPRESSION POST (U.S.G. COMPRESSION POST OR 1" EMT) EXISTING 2 X _ WOOD JOISTS EXISTING 5/8" GYP. BD. (TAPED AND SPACKLED) SCREW EYE 1 1/2" LONG 12 GA. HANGER, SLACK AND /OR SPLAY WIRE, TYP 3 FULL TURNS EACH END SCREW EYE 12 GA. SLACK AND /OR SPLAY WIRE, TYP 3 FULL TURNS EACH END HANGER, SLACK AND SPLAY WIRE - SECTION (TYP) n SCALE: 3 " =1' -0" AA505 A505 A505 A REVISION OFFICE AREA MEZZ. DCA -9 -97039 BL / JKR APPROVED DATE 8" MAX. 12 -1 -97 A505 SYM ( 5D5 FUSION 12 GA. VERTICAL HANGER WIRE W 45' 45' CROSS TEE /I�� 45' MAIN TEE MAIN TEE NOTE: HANGER WIRES "E" AND "W' ARE IN THE SAME VERTICAL PLANE AS THE MAIN TEE. HANGER WIRES "N" AND "5' ARE IN VERTICAL PLANES PERPENDICULAR TO THE MAIN TEE. CEILING BRACE - DETAIL (TYP) SCALE: NONE BY APPROVED DATE LOCATE VERTICAL COMPRESSION POSTS rr__ ________-- (U.S.G. COMPRESSION POST OR 1" EMT) PER DETAIL A500 AT 12' - O.C. EACH WAY, LOCATED 4' -0" MAX. FROM PERIMETER WALL ATTACH TO STRUCTURE ABOVE PER DETAIL gyp\ A500 USE #12 GA. SPLAY WIRE BRACING IN PLANE OF EACH TEE. VERTICAL ANGLE, 45'. MINIMUM 3 TIGHT TURNS AT EACH END. NO BENDS OR KINKS ON WIRES. 2Al2 A505 LIGHT FIXTURE BRACE - DETAIL (TYP) SCALE: NONE B®E7iW FACILITIES DEPARTMENT 6' -0" MAX 1 4' -0" I 12' -0" MAX ON CENTER MAX. CEILING STRUT - DETAIL (TYP) SCALE: NONE A505 SLACK WIRES !�' A505 12 GA. HANGER WIRES (TYPICAL) A505 LIGHT FIXTURE ATTACHED TO SUSPENDED CEILING SYSTEM WITH (2) 1/2" SELF TAPPING SMS, ONE AT EACH END A __ MAIN RUNNERS (12' -0" L TYP.) 2Al2 A505 O 0 O 0 O 0 ACCEPTABILITY iN5 DESIGN Igt SPECIFICATION IS PPPROVEO APPROVED BY DUCT DEPT. 1112 WIRE PERIMETER HANGERS, 8" MAX FROM WALLS #12 WIRE HANGERS AT 4' -0" 0.C. EACHWAY SUSPENDED FROM STRUCTURE ABOVE. CEILING BRACING AT 12' -0 "x12' -0" 0.C. (MAX) TO MATCH STRUCTURAL SYSTEM AND ON CENTER, EACH WAY. LOCATE FIRST POINT OF BRACING WITHIN 4' -0" OF WALLS. (OMIT WHERE ROOM IS 128 SQUARE FEET OR LESS) MIN. 24 GA. GALV. FLASHING 50# ASPHALTIC PAPER, MOPPED ON EXISTING ROOF DECK AND ROOFING DRAWN BY O. LOOMIS CHECKED ENGR J. REPASS CHECKED APPROVED PROVED DA EE 12 -1 -97 12-1 -97 REF. RFS162 FOR LOCATION OF DUCT PENETRATION VERIFY SIZE WITH MECH. DWGS. DUCT SQUARE DUCT DUCT PENETRATION THRU ROOF - SECTION (TYP) SCALE: NONE TlE ARCHITECTURAL MASTER LEGEND: GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OFI THE AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAININ' MATER WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE AREA OF CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING -ACILTTIEO DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IB DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. THE FOLLOWING MATERIALS IN THE AREAS ADJACENT TO THIS JOB ARE ASSUMED 73 BE POSITIVE FOR ASBESTOS: A. PIPE INSULATION B. VIBRATION JOINT CLOTH C. FLOOR TILE D. FIRE DOOR INSULATION SECTIONS AND DETAILS BUILDING 21 -03 Oi,i% . CONSTRUCTION NOTE$: 1' -6" MIN. CANT STRIP, 2 X 10 TREA 6 A505 A505 L FROM, X 4 ED CLIJRB, TYP. RECEIVED CITY OF TUKWILA JAN 1 E 1998 PERMIT CENTER DOT LAST !TENSION I SYMBOL SHEET A505 C. DATE OF JOB N0. DCA -9 -97039 DWG N0. 21- 03 -A505 sru A RNSUn OFFICE AREA MEZZ. DCA -9 -97039 r:N ;POL '►j `I mit _i111 _�_ iEISMIC BRACING ®12' -0" O.C.E.W. iEE STD. DTLS. SHT. A505 _XIST. 4"x4" T.S. COL. WITH FURRING r VINYL BASE ALL AROUND JEW CARPET BY BOEING OVER EXIST. 11/8" PLYWOOD FLOOR IMF 'MINIM rAmmA""HE I- EXIST. 1 -HR. GYP CLG. W/ ACCESS PANELS EXIST_ 6"x16" PURLINS 8' -0" O.C. EXISTING 2x4'S 2' -0' O.C. BETWEEN PURLINS SECTION SCALE: 1/4" = 1' -0" BL / JKR REFER DUCT PENETRATION DTL., SHT. A505 EXIST. CLG. - 2 LAYERS 5/8" TYPE -X GYP. BD. DATE 12 -1 -97 Sr RNSION A5061A505 7 REFER MECH. DWGS. FOR MECH. EQUIPT. A 2Al2 A506 BY REFER STRUCT. FOR MECH. EQUIPT. SUPPORT FRAME EXISTING ROOF APPROVED DATE BOTTOM OF EXIST. GLU -LAM BEAM BEYOND I EXIST. 2 HR. WALLS EXISTING CORRIDOR D. ASPLFEZAW FACILITIES DEPARTMENT FIN. FLR. - 2ND ACCEPTABILITY iws owDN ANO/DR SPECIFICATION IS APPROKU W PR . B DEPT, NOTE: PAINT WALLS TO 4' ABOVE FIN. CLG. 12 -1 -97 Amnia 2Al2 A506 SECTIONS AND DETAILS PO -0,3 D.C. SNEt1 CVO A506 DATE WALL SECTION SCALE: 3/4" = 1' -0" DRAM By 8. LOOMIS CHECKED �NCF J. REPASS CHECKED VISIBILITY ROOM 12-1-97 N n EXIST. GYP. BD. OPEN OFFICE NEW 4" VINYL E CARPET BY BOE ARCHITECTURAL MASTER CLG. (2 LAYERS 5/8" TYPE -X) 5/8" TYPE -X GYP. BD. : SIDE OF 3 1/2" MTL. STUDS ® 16" CLC. WITH FULL THICK ACOUSTIC BATT INSULATIOP - NEW LAY -IN ACOUSTICAL CLG DONN SERIES DXL WITH 24" x 48" ARM STRONG 895 CLG. TILES I I - BLOCK AS REQUIRED qg EXIST. PLYWOOD', FLOORIN i BUILDING 21- TR EA ASE ALL NG AROUND _ FIN_ FLR__�_ JOH No D 13' -0" ± RECEIVED CRY OF TUKWILA JAN 1 6 1996 PERMIT CENTER DCA -9 -97039 21- 03 -A506