Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M98-0007 - BOEING #21-03
rngg- City of Tukwila ( Permit No: M98 -0007 Type: B -MECH Category: NRES Address: 3417 S 120 PL Location: Parcel #: 102304 -9068 Contractor License No: BOEINC*294ML Signature: Date: Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Status: ISSUED Issued: 03/20/1998 Expires: 09/16/1998 TENANT BOEING #21 -03 3417 S 120 PL, TUKWILA WA 98188 OWNER SABEY CORPORATION 201 ELLIOTT AVE. WEST, SUITE 400, SEATTLE WA 98119 CONTACT GARY TALLER Phone: 206 -544 -2975 PO BOX 3707 M/S 46 -87, SEATTLE WA 98 124. CONTRACTOR BOEING COMPANY P.O. BOX 3707, M/S IF -09, SEATTLE, WA 9812.4.. ********************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL SPLIT'. DUCTLESS COOLING SYSTEM (A/C UNIT). UMC Edition: 1994 Valuation: 5:,000.00 Total Permit Fee: 58.13 -1,v -16 /2c• /1 (206) 43 -3670 ** * * **"******************** * * * * * * * * * * * ** * * * * * * * * ** * * * ** * * * * 'Kk ** * * * * ** Permit Center Authorized Signature Date I hereby certify that ,I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances;: governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Print Name: Title: This permit shall become null and.voi'd ,.f.the workiisnot commenced within 180 days from the date of issuance, or `if the, work4s suspended or abandoned for a period of 180 days from ,theias,t`'inspection. Project Nameftenanl: BOEING INFORMATION, SPACE & DEFENSE SYSTEMS Value of Construction /QU Site Address: ` 1 / 7 S , 1 11. t (�' Property Owner: TiIE 130E iNG COMPANY 03 ity Slate /Zip: 31 Tax Parcel Number: iaz?ci1 -9a6P Name: f'Irono: ?06 -M4 -?975 Street Address: City State /Zip: Fax ii: 206 544 - 2854 Contact Person: Gory Taller Phone: ?06 - 544 - 2975 Sheet Address: P.O. BOX 3707 M/S 46 - 87 Seattle, WA City State /Zip: 98124 - 2.207 Fax II: 206 544 - 2854 Contractor: ;� `ode -- ` y` 0 Sewer Phone: Street Address: �� City Slate /Zip: Fax it: Architect: Phone: Street Address: City Slate /Zip: Fax II: F.rigineer: 0 ben'! baevs1 1'■ City State /Zip: Phone: _206, • 1 P - I 7„./ /675 Fax 11: Street Address: .101 :G IA1J8Ngtiilis; kiotillrthgviEW;AN.b1AI? ,t4 Al';iltdUi~S'CEU ( rd 'FEE.FiiLLEb. Description of work to fie done: [ �/ ^ (� l t-w t 7 1 11 s ( G V..,. (, r� L. (�, V, t I sL Will there be storage of flammable/combustible hazardous material Attach list of materials and storage location on so orate 0 1/2 In the building? ❑ yes egS no X 11 paper indicating quantities & Material Safety Data Shoots Bulkhead /Docks ❑ Commercial Roroof Mechanical ❑ Manufactured Housing-Replacement only El Temporary Pedestrian Protection /Exit Systems ❑ Above Ground Tanks El Antennas /Satellite Dishes ❑ Demolition ❑ Fence cri Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting MON,ZiILYYSE1IV /CE BILLINGS.rTO :;. :: '.. .. .i ,.. ; 't /:'.'...... ,..'. ,' . ,. ',,,,i . . Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF(TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 90180 (206) 431 -3670 J # 76 7%-o3 Name: Address: [ Date application accepted: IMP O MI SCI'lv1 T.1.7OC 7/11/96 • H STAFF USE ONLY Miscellaneous Permit Application Project Number: Permit Number: Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ,APPLICANTIREQUEST pOR'MISCELUANEOUS.PUBLIC.WORKS PERMITS CI Curb cut /Access /Sidewalk ❑ Fire Loop /ttydrant (main to vault)it: Size(s): ❑ Land Altering: 0 Cut__._cubic yards 0 NIL cubic yards 0 _ __ ft.grading /clearing ❑ Sanitary Side Sewer Si: __ ❑ Sewer Main Extension 0 Private 0 Public CI Street Use El Water Main Extension 0 Private 0 Public ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage El Water Meter /Exempt II Sizo(s): ________ 0 Deduct 0 Water Only El Water Meter /Permanent II Size(s): _________ ❑ Water Meter Temp it Size(s): - Est. quantity:. gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load /Hauling WA T.ER'ME rER.`hEROS/T /RCPUND-BIL LING • Date application expires: City /Stn to /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current tee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined D1 Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Appllcat / talyn by: (initials) BUILDING OW ER OR AUTt IZ - ENT: ` Signature: I Date: /y- Print name: ary Tat l er Phone: 544 -29 5 Fax It: 544 -2854 Athlross: N.O. BOX 3707 M/S 46 -87 City /Stag /Zip:Seattle, WA 98124 -2207 ❑ ' "' ''SUMMIT APPLICATION AND: REQUIRED o e rou i1 aiiks aie`r a,.ks.,::S o ... ,� :tA Y R n .T /V1/ ;�T, f► l.l�� Qi1, pp . . .,t exceedinj'5,000 gallons andi ; n' r4iIR:Af'I1 e ,ght'ta''dle _ ' ' •�.};1 which exceeds' 2 :1 . r , CHtOKLISYS FOR ,2 ,..y• .• : RfJ • i , rly:,ii iajjt cd('ile ; g � .!,�., f.,. ; 't 1 • ; �;�:,: a e t ar, yyl Ih , ' : 'l:.al � f 'b , , 1' f, .' , r fi . „s,,k fp(,' • ,', T�s " f .A• ! x ,, ! � ' r , F r•tl f ., PERMIT' EVIEW ' ' ;. . . yb►?� t�6 l piEf {ir ?i �d' ;'�.tlr'; ;; - s7 z M,, t . b r .f ,. ;' l �fi ',4yr ','i ':'� t .� : � 4 � i n +,. F•:a• _ ( ` � a4, ie + l� s, fj a � ,, i ` ,.�)F [! i't I ?`;; f . s ; , { , l i �; r r ii iihl t �Y ? F;• , ti 4 I:,..aki. „ ci•nsp "r.i„ :'!b: • t• I i 1 �, t . t• . .. , ;".. '• *tl: Su15 c i I S ; � 111 t ;x;:kt' . C•'' ' i �..% pl+, + , 1 ( r JI4 N 'yri 4t, • : ,� ti� >'bl' :1�. #L t.it3�`!ra: { �. n ' / DW r , ' i 11 .i'. , :'. ,• , , . , r — i Awnings /Capopi No s . a a `'• ?fir 3� a ` +, ` { . , t , i`t lhn .q i t ttt �, .I :3 '.i,." .1. If rev \ ( 7.{tv G S:m. ir,.•Y•• S C o ; r • cl�tll na t ■ f rQA t t � ' r 1 X11; 'i ''�'ii1bAr " ,341t; • hermit r' z t.. it d• 1'n t }1�l .l i.t'ti'�.t. �y'�1'� ( ;, h : ✓• ' `, � ".• . ❑ . ' .I Y s.= ' • : •, ; •r,,,, ; ,, I "i;; ..,. ,- ., Buiithead /Dock r 1 'L,� �t }tit'(. • i ` �? J0, J ✓) y i , .,. • Y.. t.,,tr..•43< {'l� at,,:! ; ,lrt,,ai 1.,. :: .,i to 4 (_ .1 1 , .E , , . 1 'Stabmll�g F ai t S o � :: 1 1 ' N } {yy�MM r i it 1i r , ' ! t • . 5 1 J � ,� l{ t' 1 ?� i { f .v ,:.> r9t.•,••, Y', E'1 C,} t �:, ' +t.'A,�';il!,'ifit� ❑ Comrpe Reroof r : ( • ! 117.1 ,'t (.. Su�ir(IJ)�GI�Qf {�i�l� {1 S � . S..•l t:,' ,!, t' 3M = , ' i { { y ' f f ',;; r i +, a S 9 t• F . 1f'• lrb. '� 1�^17A 1. K' YI 't 1• ❑ J i1 'r('1 :' , i Del of t o i� � . i n 1.1 , i ; 1 'f , tYu 1t .,. .,t �J4 ; „1 r w4 , 4i ... , ,, ,..:1914 ; •, it e stl l� t N ol . J � k . F •� ,, ; .,, 1 . . sbio,∎ . 4.9 itj* GF,T: Fences - Over 6' f eet iii i-IA(gfit, r I, ' ' . •-,- -• .. ;. �` ; , Su frliti 4 04s i1 i at`i`f' r '� raA '{ y; , ; ‘ b 1,‘, 5: • : :ri`: t;a,, ., .I•.G .iSt t : :4'� } } :h ,' � 1 r , � 1. land Alterir 0 /G,radin lt?re)odds , , ,1. , { t , � , ,! s �i!?mit'ol�s�0J u , n i ?', tf ,tx r; 'iif l � r"! {, ' ri � 'i!�+�, �557f. ■�F;�3!!'1 NYii; O tQ .., <: r ,00, �' • � ,,,, , l rip .4, t, �f�'',! � aA`p,.�� f SSf r r {(� � ^'! }} r�t��q} "< .5Fi •7, it l'• , ,,.. 19101'. 0 :,. ri i irm ;�� Siibmitxohackliat >NAIA#. 1' .. •Ine» •'1;,.1 ,.�i c u'•eE••, �.. ''r'trh t, rr„ y'' , •, ∎I•'It ) t, c 9 f � , - s'E �1 + :,( .r•� l'71,� 1'; it'y , 16 ( ,. � ;si lQsidon laifonl 4 1 6;i i� is /,t� {, t7, , 3': r ,ak 1 t ; :i r�., ,•'r�i i1 ❑ i' .•„ p�'4i ',,` n4t1 t r{ ' Loading Racks, ( i , s , Y I ,C � r } , f ' rf r k {, 1 , f:t::� „f fir,' ;.,:.. ' , ' i, � as ( ;• ` �;Cr Mechanie( (Re • , ij'ti?:i9':.t :• .r y . i ,,. alt side *tlal8(Commerci..•I , t,1 i rl;. r ,�, •, i # . {,. ',.l Iii * ' (r ; , { , r s s fi a r, ❑ or;Perrp , , � ;{ ti ,r, , , _, Mlsce ilaneoiis p ,Wks •! i '.+ l t S ,; t r S' ',1 r , ,1 74 3., ,; fir? ` t'� . .�t .t.. . .. 13•? `�7 t�b'117 ; I ,,`! . �Br } , t [ ' �r{ i `('�{1 Ni ( ] ,¢, �,�(31 f,�(1� (;tl I 1 ` r o a `t 1 ' " Vt `; '4 :,. 0..' +Ybi. � :! i . ., , 1 } ;1 � 1 419,4t,1,,,.: YIrt.i. (''� Ni ie d' ousi f� p ` I S G IA';ONI:'. ' r �r ir 1 , 4.1,!o.c,ifri; .:. fF ' ;, } ' :r: : ng ( N I ..► ? 11� { r ,' `p , f ' r 1. ;” r: ,f ...s, „ ° v y � ,, ^a P ,. �p hilpli fat mi,. - ,T: y( ,' ,,(1�� �, A 'r t,., 1 . , i4h , u l i t,., 1, ,,i?.:V.,l k`ir,:1 .'1 u � M R g t 181 ' ff t �j 1 . 4 ri � Jkg, { L_J Movin Over Load(I�at t , i > ' l , ti ❑ P Lots + SUl?riiiiltch`Aci4Ii 1,`, , No, M ❑ Residential Reroof - l~xomp�'with'following ex to be repaired,orreplaced • • 1 I roof s'Lett f , H. . . ` `� " ' F ( c � epIlaJ s ( 3 kl�inp.i C °'' ;, 'rSubm .,ch ,;, ■ 0(01t6ir'' ' No3 t jt 34 t °t ; El Retallring W ; Dyer �l'iP€ t in hel lit (" . 1 t {-�--� Temporary Fa s. . , i 1 ' ', Nq1 M��7 dd¢¢ t ,•( :•rI •. ti I!, . . i :`f t'` J' S ,. n f 'S © '� t:m nor' r edest ion Pro ectfo E y 1 t d. y,P• r .t. ot. x t •.,„ ,, ' { J� t +' ` 11 ` , , :' A '� 'l ' �% r1, 't '; S c, y t i iplt tll� kllsf, i... SNbmlt"ah�yi li4t ' • ` . r "t ' ' `n"�,_ Nat ( ;� ` ,,vi ,, , ' r.r ld ., ; '^ ' �, j)41 i fy� L Y {U r :' ❑ Tree C 1• ' • t` `ELLANEOUS P r' IT • • I TIONS M r . SUB TED WITH THE FOLLOWING: ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDtNG`SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED * ` ARCHIT'ird'TURALDRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT Y STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER D CiVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) n Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Bullclh g Owner /Author(zed Agent 11 the appllcftnt is othnr(htl(f f f1 ;qYY0 a Arcl) lf ii eC r . , 1 et C '9,lf t Cli9,190(G9 l j 9 d i by the Slate of Washington, a notarized letter from llr prapa�Iy oty t�t`dtttjldr(dn�:ttte c� prlt I p sl,hn I( (Ns p�rlrlif'app((pNtlori gild obtain the permit will be regiiired as part :of this's4t1?rplttad' • . 7., s ,' , : !'. ":r,,,, `r I HEREBY CERTIFY Ti'HAT I HAVE READ AND EXAMINED TINS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY VIE LAWS OF THE STATE OF WASHINGTON, AND i AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISC.PM'1.DOC 7/11/96 f Y 4 I. ' r 4!' CITY OF TUKWILA FOHEBUILDING-,1,0 , Permit No: M98-0007 Address: 3417 S .120 PL Suite: Tenant: BOEING #21-03 'Type: B-MECH Parcel #: 102304-9068 IdA*P**********************k**Aik**k******k******k*h*kk*kl Status: ISSUED. Applied: 01/20/1998 Issued: 03/20/1998 Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and tiip_Tuic,wtla_ Building Division. 2. All permits, inspectioi plans shall be available at the iqp t6 any con- struction. Thesaiiiiments to he maintO:iy0,and avail- able until fin,aTA'nspeciA6napproM0 is granted.' 3, All constructjOn to be done :in-cOnfon,manoer*Jth approved plans and,r,eciuiremen'ts, of the Uniforiii Bui'lingcodeX1994 Edition)-as.amepde4,' Uni,forM'MaAanical,Code'(1994Eifition), and WasnAngton State Energy Code (1994 Edition) 4. Valid4jrof Permit.: The IsSUanCe'„of a perm'it,or4pprover , plans specificattons, ankdomputatlons shall Tiot,be,,cpn strued a Rermit fcir,'\or an aPproval of, any vlblatioM -C of any of provisions of 'the/building code or',of,anY,.. other,ordtroance of the jurisdiction. , No permit prumill'g to give' violate the provisions-ofhJs code ha11 he valid. 5. MANUFACTURERS" INSTALLATION:INSTRPOONS,RE9UIRED ON SITE t'4 c PLAN REVIEW /ROUTING SLIP pernem+ CooR7i Cop•I ACTIVITY NUMBER: rnae` 000-1 PROJECT NAME: k3Oe■nt� #a� -o3 J DEPARTMENT: B il: in • Divsio 4 � Public rks El Stru t DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: N Complete ❑ Incomplete Comments: TUES /THURS ROUTING: Please Route Fire Prevention r Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) \PR•ROUTE,DOC 1/98 DATE: 3 — _ 9 Planni Ckision El Permit CCoorNinator Not Applicable ❑ No further Review Required ❑ REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions El Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: PLAN VIE / OUT IVKiOSLIP ACTIVITY NUMBER PROJECT NAME BOEING BLDG #21 -03 M98 -0007 DATE 1 -20 -98 DEPARTMENT: BUILDING DIVISION El FIRE PREVENTION [J PLANNING DIVISION El PUBLIC WORKS D STRUCTURAL E PERMIT COORDINATOR J DETERMINATION OF COMPLETENESS: (T, ) .� DUE DATE 1 -22 -98 NOT COMPLETE "1 NOT APPLICABLE COMPLETE E cos NIIVIENT -n` c OL 1 oo LQ1e( TUES /THURS ROUTING: PLEASE ROUTE NO FURTHER REVIEW REQUIRED ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) Q REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS INITIAL C :ROUTE -F DATE APPROVED n APPROVED W/ CONDITIONS LI NOT APPROVED (attach comments) 0 DATE DUE DATE 2 -5 -98 • DUE DATE (Ccnitication of occupancy required. * *, k* k*** hkk• k kit * a* k * kkA* A* 4k *k•.R* tci7c;Ck;f*4*kct*I.' *.fe * 1 :3:TY OF '1'UKWI:L.A, WA * •kAk **•k4•k:i ****k*A ** **'k ***** */ *Jck *•.44't4*kk*•4kk* *' *4* * *kk*k *:1 *:1*kk TRANSMIT Number: R9700730 Amour►•t;: 58.13 03/20/98 11:00 Payment Method: CASH Notation: HOEING Init: BLM M - Permit No: M98 -0007 Type: 13-MECH 'MECHANICAL PERMIT Parcel No: 102304 -9068 S i t e Address: 3417 :3 120 PL Total Fees: 513.13 This Payment 5E1,.43 Total ALL Pmts : 58.13 Halanr,e: .00 *** d.* d4*: 1** A** 4o** * ** *c4*A » *k *•k•w * * *k ** *** k *k*. *' *A• *A * *4** *• Account Code 000/345.830 0:)0/322.100 MECHANICAL 7 NONRES Description PLAN CHECK -• NL)NRES TRWN8MIT Amount... 11.63" Project: LW Type of inspecti•rr I Address: ��. 5 �� ()cc6gy(lkL..._ pate called: Date wanted: 4 q 1? Special instructions: as Requester: f Phone No.: _I 1 _ 3 .- 7 4 Z e... INSPECTION„ FIECO - -,. Retain a copy with pedal INSPEC ON NO. CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector Date: PERMIT NO. 20 431 -3670 Corrections required prior to approval. P r $42.1 REINSPECTIO ! FEE RWIRED. Prior to inspection,, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. Receipt No.: Date: SCOPE OF PROJECT = CONSTRUCTION NOTES -4152 -4152 -4152 -4052 -4152 MAIN D MAD w* R,SQUIRES AMMO MI — 1-7-98 ( -1.18 TO INSTALL A SPLIT SYSTEM AIR CONDITIONER UNIT. WITH THE INTERIOR UNIT MOUNTED ON THE WALL AND THE EXTERIOR UNIT MOUNTED ON THE ROOF 6, GAR t GAN f ' ,.11.• I> MOUNT INTERIOR EVAPORATOR UNIT OF SPLIT SYSTEM AIR CONDITIONER ON EAST WALL OF DATA CLOSET. MAINTAIN BOTTOM OF UNIT AT 3' -6' AFF, MAINTAIN CLEARANCE OF DATA RACK ON THE RIGHT SIDE.' CONNECT CONDENSATE PUMP TO A/C UNIT AND POSITION ON THE FLOOR TO BE ACCESSABLE FOR MAINT, , ROUTE DISCHARGE OF A/C CONDENSATE PUMP NORTH TO -4052 JANITORIAL CLOSET AT TOP OF STAIRS AND DISCHARGE INTO MOP SINK AT COL. G1, INSTALL WALL MOUNTED A/C CONTROLLER AT 5' -6' AFF ON WEST FACE OF VERTICLE DUCT ENCLOSURE,<AT EAST END OF ROOM) ROUTE INTERCONNECTING WIRES BETWEEN CONTRIOLLER AND A/C UNIT. MOUNT A/C CONDENSOR UNIT ON ROOF AS CLOCE TO INTERIOR UNIT AS POSSABLEJTO BEAR DIRECTLY ON EITHER COLUMN LINE 2 OR COLUMN LINE H. LIQUID INTER TIE 1/2' EVAPORATOR ANDCONDENSOR UN Tt W " LINES BETWEEN HVAC -- DATA CLOSET 21 -03 BLDG, METRO DOOR 23G2 41/oE7A40 MAR 1 8 1998 AS NO 11U LGId ' D1V1:�tt Iwo. M 757656 -03 ww�a wa SK # 01079875D . - ''''' • - ENVIRONMENTA Lichert I12(}0() c(h)ling system pruvides veal '1 cm)ling tor y( fir electronic hals, in a quiet, easily installed package. • Easy to install system requires no ductwork — simply connect the wall-mounted indoor evaporator 11 14 unit to the outdoor con ensng . r through a*11orgeilin' • , to••••:4A • ,, • , At.. •„ • 'S*1 • 1 a . • 4 1 .1 N4,46-finol vt "4'2 • • 4 a. .UIET;2&i EBER 1M coo ils THeIDEAVCORLINGJSuLUTioN 01aLECTRO • ,:s?9,....% 4e,' LOADS IN AN 'OFFICEENVIRONMENT'.OR IN ,; . '.,■ •- ' •••;%" • , ROOMS REQUIRING LOW NOISE AND A SMALL CABINE1': • TELECOMMUNICATIONS ROOMS III PC LABS • SEcuRrry CoNnoi, Rooms • INDusTRIAL CoNTRoi, Rooms • Niurvon Rooms • Spar cool RA( LARGER ROOMS • TWRADIO STUDIOS •dt'ill'A 1.-.:J•• r E F F E C T I V E Q U I E T • WHEN YOUR ELECTRONIC INVESTMENT NEEDS A COOL ENVIRONMENT, AND YOUR OPERATORS REQUIRE A QUIET WORK SPACE, LIEBERT HAS THE SOLUTION. THE LIEBERT LM 2000 COOLS YOUR SPACE TO THE TEMPERATURE REQUIREMENTS OF ELECTRONIC EQUIPMENT, BUT RUNS SO QUIETLY IT ADDS VIRTUALLY NO SOUND TO AN OFFICE OR EQUIPMENT ROOM. OOM OR SPOT COOLING. LM2000 is a convenient solution for rooms with small to moderate cooling requirements, or as an economical solution to cooling a "hot spot" that is bypassed by existing air conditioning. The unit also has automatic or manually selected "dry" or dehumidification cycles to prevent problems associated with excess humidity. Directional vanes allow you to program cooling with a sweeping motion, or to fix the air flow to an area where cooling is needed. And unlike conventional air conditioning, LM2000 is available to protect your electronic systems even when outdoor temperatures are as low as 0 °F (optional wind baffle required). FFICE - SUITABLE NOISE LEVELS The split system design places the condensing unit outside, leaving only the virtually silent evaporator unit in your critical space. At 43 -50 d6A, the LM2000 is far quieter than alternative cooling methods, and is generally quieter than the equipment it is cooling, adding little or no noise to the room. High and low fan speeds offer further control over noise output, as well as cooling control. , POWER — MODE SELECT FAN ) COOL/DRY) TEMPERATURE WARMER' COOLER ' TIMER MODE ) HOURS ) FAN SPEED LOW/WCH) AIR SWEEP ON /OFF) C EdC TEST RUN The wall - mounted controller can operate 1 -50 units from a centralized location. RECEITUKW ILA CITY OF JAN 2.0 1998 PERMIT CENTER USER- FRIENDLY CONTROLS The wall- mounted control system is clearly labeled with control and monitoring parameters, allowing instant access to system information and operation. Parameters include: • Operation Mode Setting (Auto, Cool /Dry) • Temperature Setting (in units of 2 °F) • Self Diagnostic Display • Room Temperature Display • 24 -hour On /Off Timer • Fan Speed Indicator • Louver Control (adjusts air flow left to right) • Non - volatile memory (for storing operation functions) "OW )iiiiiiig) rtrl THE LM2000 DESIGN MAKES IT A COST EFFECTIVE CHOICE FOR VIRTUALLY ANY ROOM, SAVING MONEY ON INSTALLATION AND MAINTENANCE AS WELL AS A LOWER INITIAL PURCHASE PRICE. ;EASY INSTALLATION. LM2000 is quickly and easily installed at your site without ductwork or costly renovations. • The indoor unit is connected to the outdoor condensing unit with refrigerant lines through a single, 3" diameter opening in your outside wall. Condensing units are pre- charged with R -22 for up to 100 feet of refrigerant piping. The condensing unit may be located up to 164 ft. from the indoor air handler, using conventional refrigerant lines and adding R -22 refrigerant. • Condensing unit design further simplifies installation by offering four connection access sites: front, rear, side or beneath the base. MULTI -UNIT CONVENIENCE • For sites where multiple LM2000 units are installed, up to 50 systems may be operated from a single monitor /control panel, simplifying installation and resulting in cost savings. • Multiple connection access allows up to 10 outdoor condensing units to be installed in -line, resulting in significant space savings. This design also offers greater flexibility in piping and installation. Condensing unit components are front accessible for easy service. ±EASY MAINTENANCE AND SERVICE • Condensing units are completely front access for all critical components, simplifying service and maintenance. • The wall- mounted unit control panel includes a self - diagnostic feature, indicating specific problems for easier and faster repair. Trouble shooting indicators pinpoint problems with wiring, thermistor, drain pump, coil frost, programming, out of phase, and other critical parameters. ■ Local service and parts are available from your factory- trained Liebert representative. RECEIVED CITY OF TUKWILA JAN 2 0 1998 PERMIT CENTER System Specifications 80 °F /50% RH Total BTUH Sensible BTUH Power Consumption, kW 75 °F/50% RH Total BTUH Sensible BTUH Power Consumption, kW FAN DATA — DIRECT DRIVE High Speed CFM Sound Level, dBA Low Speed CFM Sound Level, dBA Liquid Line, in. Suction Line, in. Condensate Drain, in. Weight, lbs. Voltage, ph, Hz Minimum Ampacity Max Fuse Size (time delay) Airflow, cim Sound Level, dBA Weight, lbs. Voltage, ph, Hz Minimum Ampacity Max Fuse Size (time delay) LMW012A ' I LMW018A LMW024A 18000 12200 1.70 17100 11700 1.66 600 49 460 43 x.41. •v.il CONNECTION SIZES 3/8 5/8 1 WEIGHT 68 ELECTRICAL PROPERTIES 115 Volt,1 P 1 15 LMP012A LMP018A LMP024A LMP030A 1590 53 154 08/230 Volt, 1 16 20 LMW030A ' 28800 17200 2.94 27000 16500 2.82 600 50 460 44 1/2 3/4 1 69 3170 55 208 ELECTRICAL PROPERTIES 20 30 m.•r . r: OOUNG 0 95'IDB Oun oo R AMBIENT,1 E CORPORATION 050 DEARBORN DRIVE P.O. Box 29186 COLUMBUS, OHio 43229 800.877.9222 PHONE 614.84 1.6022 FAX upstech@llebert.com EMAIL �EBERT WEB SITE i ttp://www.11ebert.com GLOBE PARK MARLOW BUCKINGHAMSHIRE SL7 lYG UNITED KINGDOM +44 1628 403200 PHONE +44 1628 403203 FAX • INDOOR UNIT 19/F, CAUSEWAY BAY PLAZA 1 489 HENNESSY ROAD CAUSEWAY BAY HONG KONG 852.2.572.2201 PHONE 852.2.831.0114 FAX OUTDOOR UNIT RECEIVED CITY OF TUKWILA JAN 2 0 1998 PERMIT CENTER O 1996 Lieben Corporation. All rights reserved throughout the world. Speddcatlons subject to change without notice. • Lieber, and the Uebert logo are registered trademarks of the Lieber, Corporation. SL•12000 (l/97) Printed In U.S.A. LMP012A LMP018A LMP024A LMP030A W 34 -1/4" 34 -1/4" 34 -1/4" 34 -1/4" D 11 -5/8" 11.5/8" 11 -5/8" 11 -5/8" H 25 -9/16" 33 -7/16" 49 -1/2" 49 -1/2" A 19-11/16" 19-11/16" 19- 11/16" 19-11/16" B 5-5/16" 5-5/16" 5 -5/16" 5 -5/16" C 13 13 13 13 System Specifications 80 °F /50% RH Total BTUH Sensible BTUH Power Consumption, kW 75 °F/50% RH Total BTUH Sensible BTUH Power Consumption, kW FAN DATA — DIRECT DRIVE High Speed CFM Sound Level, dBA Low Speed CFM Sound Level, dBA Liquid Line, in. Suction Line, in. Condensate Drain, in. Weight, lbs. Voltage, ph, Hz Minimum Ampacity Max Fuse Size (time delay) Airflow, cim Sound Level, dBA Weight, lbs. Voltage, ph, Hz Minimum Ampacity Max Fuse Size (time delay) LMW012A ' I LMW018A LMW024A 18000 12200 1.70 17100 11700 1.66 600 49 460 43 x.41. •v.il CONNECTION SIZES 3/8 5/8 1 WEIGHT 68 ELECTRICAL PROPERTIES 115 Volt,1 P 1 15 LMP012A LMP018A LMP024A LMP030A 1590 53 154 08/230 Volt, 1 16 20 LMW030A ' 28800 17200 2.94 27000 16500 2.82 600 50 460 44 1/2 3/4 1 69 3170 55 208 ELECTRICAL PROPERTIES 20 30 m.•r . r: OOUNG 0 95'IDB Oun oo R AMBIENT,1 E CORPORATION 050 DEARBORN DRIVE P.O. Box 29186 COLUMBUS, OHio 43229 800.877.9222 PHONE 614.84 1.6022 FAX upstech@llebert.com EMAIL �EBERT WEB SITE i ttp://www.11ebert.com GLOBE PARK MARLOW BUCKINGHAMSHIRE SL7 lYG UNITED KINGDOM +44 1628 403200 PHONE +44 1628 403203 FAX • INDOOR UNIT 19/F, CAUSEWAY BAY PLAZA 1 489 HENNESSY ROAD CAUSEWAY BAY HONG KONG 852.2.572.2201 PHONE 852.2.831.0114 FAX OUTDOOR UNIT RECEIVED CITY OF TUKWILA JAN 2 0 1998 PERMIT CENTER O 1996 Lieben Corporation. All rights reserved throughout the world. Speddcatlons subject to change without notice. • Lieber, and the Uebert logo are registered trademarks of the Lieber, Corporation. SL•12000 (l/97) Printed In U.S.A. LMP012A LMP018A LMP024A LMP030A W 48-1/16" 60 -1/4" 60 -1/4" 60 -1/4" D 8-11/16" 8- 11/16" 8-11/16" 8- 11/16" H 14-3/16" 14-3/16" 14 -3/16" 14 -3/16" System Specifications 80 °F /50% RH Total BTUH Sensible BTUH Power Consumption, kW 75 °F/50% RH Total BTUH Sensible BTUH Power Consumption, kW FAN DATA — DIRECT DRIVE High Speed CFM Sound Level, dBA Low Speed CFM Sound Level, dBA Liquid Line, in. Suction Line, in. Condensate Drain, in. Weight, lbs. Voltage, ph, Hz Minimum Ampacity Max Fuse Size (time delay) Airflow, cim Sound Level, dBA Weight, lbs. Voltage, ph, Hz Minimum Ampacity Max Fuse Size (time delay) LMW012A ' I LMW018A LMW024A 18000 12200 1.70 17100 11700 1.66 600 49 460 43 x.41. •v.il CONNECTION SIZES 3/8 5/8 1 WEIGHT 68 ELECTRICAL PROPERTIES 115 Volt,1 P 1 15 LMP012A LMP018A LMP024A LMP030A 1590 53 154 08/230 Volt, 1 16 20 LMW030A ' 28800 17200 2.94 27000 16500 2.82 600 50 460 44 1/2 3/4 1 69 3170 55 208 ELECTRICAL PROPERTIES 20 30 m.•r . r: OOUNG 0 95'IDB Oun oo R AMBIENT,1 E CORPORATION 050 DEARBORN DRIVE P.O. Box 29186 COLUMBUS, OHio 43229 800.877.9222 PHONE 614.84 1.6022 FAX upstech@llebert.com EMAIL �EBERT WEB SITE i ttp://www.11ebert.com GLOBE PARK MARLOW BUCKINGHAMSHIRE SL7 lYG UNITED KINGDOM +44 1628 403200 PHONE +44 1628 403203 FAX • INDOOR UNIT 19/F, CAUSEWAY BAY PLAZA 1 489 HENNESSY ROAD CAUSEWAY BAY HONG KONG 852.2.572.2201 PHONE 852.2.831.0114 FAX OUTDOOR UNIT RECEIVED CITY OF TUKWILA JAN 2 0 1998 PERMIT CENTER O 1996 Lieben Corporation. All rights reserved throughout the world. Speddcatlons subject to change without notice. • Lieber, and the Uebert logo are registered trademarks of the Lieber, Corporation. SL•12000 (l/97) Printed In U.S.A. CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL DATE: .7; c J re PROJECT NAME: PROJECT ADDRESS: CONTACT PERSON: GARY TALLER REVISION SUMMARY: BOEING DEFENSE 8 SPACE GROUP SUBMITTED TO: A e-e3c, L4o PLAN CHECK/PERMIT NUMBER: I"` / 0 "CoO7 o r� 7.ovT SHEET NUMBER(S) 1 ZF S I (0.0 k. SEGO "Cloud" or highlight all areas of revisions and date revisions. • • " r�4:'f7.NVltffttiy tyVMr 'tier►: 'ern • r. r r•�•` •.♦ �f..� L• c' aN... Y. Ytl 1�/.]) Ca:Lr_.S�w.)..4••fA�llwa.].:.)f � h. PHONE: 206 -544 -2975 RECEIVED CITY OF TUKWILA MAR � 199$ PERMIT CENTER enteccc' Sle( CQ.. February 2, 1998 Mr. Gary Taller The Boeing Company P.O. Box 3707, M/S 46 -87 Seattle, Washington 98124 Dear Mr. Taller: Building Division: John W. Rants, Mayor Department of Community Development Steve Lancaster, Director SUBJECT: LETTER OF INCOMPLETE APPLICATION Mechanical Permit Application Number M98 -0007 Boeing #21 -03 3417 S 120 PI This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 20, 1998, was determined to be incomplete. Before your permit application can begin the plan review process the following requirements from the Building Division must be met. Contact Bob Benedicto, Sr. Plans Examiner, at 206 -431 -3670 if you have any questions regarding the following comments. 1. The drawings do not show proposed location ( "data closet ") of split system a/c unit - drawings seem to be for a different job. The City requires that two (2) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not required revised plans but requires additional reports or other documentation please submit five (5) copies of each document. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Soutlzcenter Boulevard. Suite #100 • Tukwila. Washlneton 98188 • 12061 431.3670 • Fax 1206) 431366S Mr. Gary Taller February 2, 1998 Page 2 Sincerely, If you have any questions please contact me at the City. of Tukwila Permit Center at (206) 431 -3672. -7/dag,Lleda,z)9 Kelcie J. Peterson Permit Coordinator Enclosures File: M98 -0007 I SYM A B REVISION gt POUT VISTIrl,: LAV 5101( KR PSo /A/c COND. PUMP DRAIN DO 6000 4076 REV 7/S3 j 757656 bY PM) C,4 RAD APPROVED 4 'gay M16-0007 DATE 3 q • 91 SYN1 REVISION PLAN n 1/8"4 BY ApeliOvED DATE AlinfrAFIAW FACILITIES DEPARTMENT 0 AUBURN, WA. 98002 0 EVERETT, WA. 98201 0 KENT, WA. 98031 0 PORTLAND, OR. 97220 0 RENTON, WA. 98888 •SEATKE, WA. 98124 APPROVED BY Permit No. e..323 P. E.'uthorize the violation Cf otopl,,I code or ordlnence. Receipt of conliactor's copy of app ed plans SEPARATE PERMIT REQUIRED MECHAN01 VELECTR:CAL • C.1:-.IUME:NO pip;,zq C st :LA Ej,LD:1•1•3 Div;S!ON ACCEPTABILITY THIS DESIGN ANDIOR SPECIFICATION IS APPROVED SUBTITLE 2" GIP( OF TIVIIIA APPROVED MAR U) LEGEND: NOT No ; testlizAw• Frtzom M.KINSTte.Y Dvqcq Ws' . LIC:43 ; ao4 , REV s ic) .4057 4058 PIPING PLAN MECHANICAL MASTER LOG ,?.1 COL. E /1 COLD WATE... -- --, H vs/ HOT \A/Ai Pt= OIZINKINel FOUNTAIN GENERAL NOTES: I)FIELD VERIFY DIMENISION5 COW C7 PrIoTc DE C...01 ION . CONSTRUCTION NOTES: [:> SEE SKETCH 4 0/ 073 e 75i KEY PLAN r PERN CEN rR , -■!:— 4051 4 2 / 4055 4053 4056 r 4054 ' IDWG D - O7C1. ' JLI VR Y•D 170 v.. CFM , ®• • • • .150 CFM -._, 260" ¢i VC. V.. 550 eFM 12 221160 c.M le' 4 2 4/_12 -.250. CFM I 170, 54 .cf14 14 /12(surred 500 CFM ' 10 14/ 2 wv. 125 GFM (3- r-) 12 /lo Vv. Els ( 45 \ Er" 24 !o P) 24/!0 p 24/ N 37 5 24 /(0 to "d (3 Tl'F) 8"0 2_0'96 12"56 14 °¢ 2"96 115 C!�F, M V E24/(6 M OW ADD U0,- 545,4.4 VIEWa 40 EJG 12//88 A/C UNI: AT COL N•2 T' 75765612RAD ' -( I.1 16 10' so (4 TYP) 22/160 i ) 4 22 "� V.D v.a 410 CPm (4 T"(P) say CFFv1 C4 TY I°) 24/24 N 24 cFm (4 400 375 CFM lo'# 375 CFM ICE (4 TIP) 2z /1� Y . r �a y 16000 srr my APPROVED DATE REV.. w APPROVED I2 '0 PLAN I /e "-0'1 X11 .I' FAO' ` 3 PEPAIMNAT LEGEND :.. . 712::1 SUPPLY AI 12 (UP 012TOWAl2 ) =._ = 5UPPLYA112(00WN "ki= RETUi2N /1.112(UP 012TDWA;'ZJ) "41::] RETURN AIIZ(.bOWN 012 AWAY 5U1°PLY AUz. INDICATO`Z - -•- RETU12N AIR IMDICA.TC # VOLUME 0AMI =8r FUZE 0AM1PER SOUNb ATTENUATOr__ 2--► —t 12EDUCE1?-- . f FLEX CONNECTION FLEX pUCT CEILING 171��US'�2 OT THERMOSTAT opt, GENERAL NOTES: : !1)FIELD VEI2.IKY CONDITIONS 1.12!C; ?- - TO DESIGN - CONSTRUCTION. 2)FO12.MECHANICAL ROOM NO12T!H 0= COL. !,es OW 4102 - ma 'A)POI2 EQUIPMENT SCHE0ULE5 SEE .bWCa.S 4101 -M24 M3. F0I2TYPICAL SOUND ATTENUAT'?'r S EE DETAIL M -! 4.4102 -M F012TYPICAL 5ECUIZE FEI"ZI IV! E PUC.T':PENETZATION (50 50. IN. "LXIZE1Z)' S DETAIL M-1 4;01-M4 .FORTYPICAL- DUCT PENETR/- :T10 :OF M ECHAN I Co-L 1200 tv1 5EE IDETAI L I H-I4.4102- X13 CONSTRUCTION NOTES: SEE SKETCH 0107987!" n 4157 4155 ;4.0 VOW, .,. � . EVER T, ' WA . 98201 © •" V IT: F/1 9 82 R.V 1 0 @'I TIAN,9. 0 97220 Q 'ON, WA,.98Q '71E, E, WA 94 :.w6.lt FROM MC.KINSTIZ`P _ptWq M -3J, ';.[QM3 N8304, KEN( HVAC;PLAN. , 4151 4153 4154 MECHANICAL MASTER G'TM o° 97 ��(I L L 1S.R. 1751ffie7"--- ii 7 r PERMIT CENTER !, DNG'7 LOG. `21-03.2 0H /1-4 D:C.; 1 21 - 00' ° } 9 x 37 3/8 GLB : 8Y APPROVED' N�/ \ � SYM 7 x 34 1 C3 'D \ 4 4 DATE 4 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS PROVED DRAWN M. DIT MAR 9 x 29 1/ GLB CURREIJT Rc /iSID;! GUtOaoR uNlr A 9 x 34 1/8 LB 3/5/98 9 x 37 3/8 CLB CHECKER 7 x 34 1 LB I APPROVED BY DE DE PT. DATE 9 x 29 1/4 GLB TITLE BULLING 21-03 . R F STRUCTURAL MASTER COL. 1- 4.5 /H -N CORP. PARK sHEET e 9 x 34 1/8 GLB MECHANICAL EQUI•MENT SUPPORT FRAME SEE DWG. No. 1.1- 003 -100 -S13 ;,8 /1. 0 - ,8 @ 9 1x9 o 7 x 4 1/ = CHECKED TYP. EXIS 2x4 ®24° 1 /2''PLYW (2) 2x8 (TYP) SIMPSON HA EA. END (2) 2x8 . PANELIZED C DF #2 OD CDX 32 26 -2 GER @ F ALL :or MECCHANI AL EQUIPMi JT SUPPORT SEE DWi. No. 121- 103-1007-5 FRAME 0 � 4>12x10' D CT SUPPORT - CURB -- SEE DEL. 3 ON 121 -0O3- 1132 -S2 / I Alla 1 9 x 34 1/8 GLB APPROVED �4 F O \ � / Or JOIST (WAS N. 107-217. 04 9 x 29 1/ 1007 S ?1) GLB \ 9 x 37 3/8 GLB APPROVED G LB 3- � RF 162 121 -00., 1032 -52 � ,9 x 37 3/8 GLB SIMPSON U26 -2, JOIST HANGER EA. E D OF ALL (2) 2 8 ✓ i' ��\ 7 x 34 1/8 GLB 9 x 29 1/4 GLB 9 x 34 1/8 GLB GHANICAL EQUIPM =NT SUPPOR FRAME DWG. No 121 -003- 1007 -'13 ` , (2) 2x8 (NP) i t Allik 003 - 1032 S2 'FS162 S2 121- 9 x 37 3/8 GLB yu x 34 1/8 GLB 9 x 29 1/4 GLB n 9 x 34 1/8 GLB SYM REVISION : 8Y APPROVED' .DATE SYM REVISION B; APPROVED DATE 4 4 E7A'� ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS PROVED DRAWN M. DIT MAR DATE 9 -18 -97 SUBTITLE ROOF FRAMING PLAN CURREIJT Rc /iSID;! SYIAE�. A INSTALL COOLING UNIT JOB #757565 - 03 MA ,1 3/5/98 CHECKER APPROVED BY DE DE PT. DATE TNONEER TITLE BULLING 21-03 . R F STRUCTURAL MASTER COL. 1- 4.5 /H -N CORP. PARK sHEET e CHECKED APPROVED APPROVED DWG ND. 2 x ME SE 9 x 37 3/8 GLB I 600 8' -0" 9 37 3/8 GLB 8' -0 60' -0" TYPICAL 9 x 29 1/4 GLB �J LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: RFS166 RFS164 RFS167 RFS165 RFS163 KEY PLAN RECEIVED j CRY OF TUKWILA MAR 119 1998 SYM co 1/2" PLYWOOD DECKING GL 9X 7 0 W J REVISION. !Z , INSTALL COOLING UNIT ',JOB #757565 03 73/8 50 DUCT SUPPORT, TYP(2)PLS 14"X12"DUCT C/C u l MA PARTIAL ROOF PLAN Olt APPROVED 6 u 30" SCALE: 1/8" = 1'-0" 30 , 0 ,, _ CONCRETE' FINISH FLOOR ELEV. DATE 3 SY RAISED FLOOR' SECTION REVISION LLJ it SCALE: !1/4" = 1' -0" OUTSIDE GRADE ELEV. A 1 A10 L500 APPROVED 30• -0 1 {-1 DUCT MOUNT. DE VAIL SCALE 1" = 1' -0 L2X2X 1/4 5 1/2" CONCRETE WALL 1/4" DIA X 1 1/4" LG HILTI METAL HIT ANCHORS ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED ' APPROVED BY DEPT © OUTDOOR COOLING UNIT: 34 "Wx12 "Dx50 "H, 208 LBS TOTAL WT. 5500 DO EXIST. 9x29 1/4 GLB 454 P.T. ALONG PERIMETER, TYP. 1' -7 1/16" I 2' -10" SECTION SCALE: 1/4" = 1' -0" RF5162I 5500 101' NEOPRENE BOOT SEAL 'AROUND EDGES ROOFING MATERIAL 3/8 "0 TH'D ROD ANCHOR, 4 TYP, FASTEN ALL 4x4'S W/ (2) "SIMPSON" LS30 CONNECTORS & 10d NAILS O Q O (n m 0_ ao d OUTDOOR COOLING UNIT CONTACT FUGET SOUND MAINT, TO PROVIDE FLASHING & WATER PROOFING Je 4x4 P,T. ALONG PERIMETER, TYP. 3/8 "0 THR'D ROD & NUTS L3x3x3/8 ANGLE, 18 ",LONG 1/4 "0 THR'D ROD & NUTS 454 BLOCK, 2' LONG SECTION SCALE: 1/4" = 1 S500L500 1/2" PLYWOOD DATE DRAWN J.BURKS CHECKED ENGINEER J.BURKS CHECKED APPROVED . APPROVED' C3X5 2.5 ", SQ. A36 STEEL PLATE 1 1/2" SCH. 40 PIPE 12" LG. 1/2" DIA. X8" LG. HEX HEAD BOLT', W/ HARDENED WASHERS EACH END, (2 BOLTS PER CONNECTION SPACED 3" APART) SECTION SCALE: 3" = 1' -0" D ATE SUBTITLE 10/10/94 10/10/94 TI EXIST: 9x29 1/4 GLB 1/4 V 1/4 V/ 1/4 A36 STEEL' PLATE X 5 LONG. ( S500,I 5500 1/4V MISC. SECTIONS AND DETAILS BUILDING 21 -03 STRUCTURAL MASTER COL. X - /X -X CONSTRUCTION' NOTES: Y Or F:.ICVII_ AP PR D.0 r2 CURRENT REVISION SHEET JOB NO (MONO. SYMBOL S500 7575765 -03 21- -5500 RE CITY O MAR D 9 1998 PERMIT CENTER V 2X4 A2 CC U 1/4 1/4 C3X5 -\ SECTION SCALE: 3" = 1' -0" C3X5 -6X16 D.F. NO. 2 LEGEND: GENERAL NOTES: 1.VERIFY ALL DIMENSIONS IN HE FIELD 2. AIR BLOWER WEIGHT APPRO) r TEL`, -' 3, WELDING SHALL BE BY A CERTIFIED t X ',ELDER PER A.W.S. SPECIFICATION.. 4. STEEL SHAPES AND PLATES SHALL BE A36. 5. PAINT DUCT AND CONDUIT TO MATCH OUTSIDE COLOR OF BUILDING. PUGET SOUND MA I NTENA . ROOF PENETRAT I ONS. I ._OE'REIJL ROOFING MATERIAL .H ALL I'EyIEIU. 10I BE SEALED BY PUGET S. U :0 IF. .