Loading...
HomeMy WebLinkAboutPermit M98-0008 - TACO TIME RESTAURANT1 a00 1 7 - 1 - nte- e_5"-Iwn-LieprLf nitcV- wog City of Tukwila 1 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Address: 6820 S 180 ST Location: Parcel #: 362304 -9105 Contractor License No: PACIFSP117B7 TENANT TACO TIME RESTAURANT 7820 S 180 ST, TUKWILA WA 98188 OWNER HOME DEPOT 2455 PACES FERRY RD NW, ALTANTA GA 30339 CONTACT LANCE CARLETON 17476 174 ST SE, MONROE WA 98272. CONTRACTOR PACIFIC STAINLESS PRODUCTS INC , BEAVERTON OR 97005 ***********************,******************** * * * * * * * * * * * * * * * * * * * **** * *** * * ** Permit Description: UMC Edition: 1994 Permit No: M98 -0008 Type: B -MECH Category: NRES FABRICATE & INSTALL HOOD & EXHAUST SYSTEM. ****** ***** {***************** * * * * * * * * * * * * * * * * * * * * ** * * . * * * ** * * * * * * ** Per it Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances.': governing this work will be complied with,..whether specified herein or not. The granting of this permit does not presume to give authority t,o.violate or cancel the provisions of an other state or local laws- regulating construction or the perfor i wor I.am authorized to sign, for and o• bum g pe Print Name: 104. Valuation: Total Permit Fee: Title: Status: ISSUED Issued: 02/10/1998 Expires: 08/09/1998 Phone: 404 433 -8211 Phone: 360 - 794 -7709 Phone: 360 - 794 -7709 (206) 431 -3670 10,000.00 99.69 This permit shall become null and if the work,.is :;not commenced within 180 days from the date of issuance, or i f the . ..work ." is suspended or abandoned for a period of 180'.da.ys from the last inspection. Project Name/Tenant: — Description o work to be done: Value of Construction: Site Address: Cit State /Zip: Tax Parcel Number: Property Owner: / Phone: Phone: Street Address: 0 co F `, � kr - it ) y� t Z City /State /Zip: Contact Person: bJw C t,(e 0 Water 0 Sewer 0 Metro Street Address: City State /Zip: Contractor: � C- gip - S • PO ASS X. 26- Street Address: /7 I !( City State /Zip: a P wtC} `g ??z- Fax #: 360 '7 `f eVi Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description o work to be done: , t ' .' ' . t ..-- r . 4 i P L ; -. #; S, Will there be storage of flammable /combustible hazardous material in the building? El yes El no Attach list of materials and stoma a location on se arate 8 1/2 X 11 a er Indicating uantities & Material Safet Data Sheets ■ Above Ground Tanks LJ Antennas /Satellite Dishes Bulkhead /Docks Commercial Reroof ❑ Demolition El Fence Sff Mechanical El Manufactured Housing - Replacement only El Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities El Tree Cutting MONTHLY SERVICE BILLINGS .TO:. :: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY Or TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Numbers Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. AP.PLICANT.0 REQUEST: FOR MISCELLANEOUS. PUBLIC WORK'S `PERMITS 'r` ❑ Channelization /Striping El Flood Control Zone ❑ Landscape Irrigation El Storm Drainage El Water Meter /Exempt # ❑ Water Meter /Permanent it ❑ Water Meter Temp # El Miscellaneous ❑ Curb cut/Access /Sidewalk El Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only WATER METER DEPOSIT /REFUND BILLING: Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load /Hauling Name: Address: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 016 • Date application expires: 1.2.0 Alb Applicatl 1 by: (Initials) MISCPMT.DOC 7/11/96 Phone: City /State /Zip: , :fr [c���ji P :re'. AU _:! ff...!. SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW .r WARIF Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 Submit checklist No::, M -9 , El ____ Fri nam =. ` "...1 i t e 411 Air - l Pu L i z Date: .__. 1 — Commercial Reroof 9 7/� ❑ Fa, ceo 0a.1,, Address: l // b Submit checklist NO: M =9 ❑ I r! 'C---' _ . _ . - _ City /Stale /Zip:�jf IBC )/ J LIB - C414- �/ e m -7z-- o ff ALL MISCELLANEOUS PER , APPLICATIONS MUST BE SUBMIT ' WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN D. BUILDING'tITE PI41NS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered; architect /engineeror` contractor liconsed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DQC 7/11/96 S'y ' tW SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW ❑ Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 Submit checklist No::, M -9 , El Antennas /Satellite Dishes ` Submit checklist No M=1.;" I n Awnings /Canopies - No signage Commercial Tenant Improvement Permit , ` i n Bulkhead /Dock Submit checklist No M-10,. ; ❑ Commercial Reroof Submit checklist No M ' ❑ Demolition. Submit checklist No, :;M 3, M`3a . ' ❑ Fences - Over 6 feet in Height Submit checklist NO: M =9 ❑ Land Altering/Grading /Preloads Submit checklist , No: M -2. in Loading Docks / Commercial TenantImprovement , Permit..; Submit checklistNo;.H-17 j Mechanica4agfilitn2444 Commercial) Submit checklist No... M=8;. Residential only - .H -6,: H 16 . _ . in Miscellaneous Public Works Permits Submit checklist ` No :.H 9 71 Manufactured Housing (RED INSIGNIA ONLY): "Submit checklist No M -5: El Moving Oversized Load /Hauling =` ; Submit checklist • •;'NO: M -5'" . : ❑ Parking Lots Submit checklist.;; No: M -4 , i n Residential Reroof - Exempt with following exception: If roof structure;. to be repaired or replaced ResidentiatBuilding:Permit :. Stibmit.checklist .. :No:.M-6, ,; ❑ Retaining Walls - Over 4 feet in height Submit "checklist`.•:No : , .. M - in Temporary Facilities Submit checklist No' M-,7. ', ❑ Temporary Pedestrian Protection/Exit Systems Submit checklist. No M-'4 ❑ Tree Cutting Submit checklist . No :. M 2i. "': ALL MISCELLANEOUS PER , APPLICATIONS MUST BE SUBMIT ' WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN D. BUILDING'tITE PI41NS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered; architect /engineeror` contractor liconsed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DQC 7/11/96 S'y ' tW Address: 6820 S 130 ST Suite: Tenant: TACO TIME RESTAURANT Type: B -MECH Parcel #: 362304 -9105 CITY OF TUKWILA Permit No: M98 -0008 Status: ISSUED Applied: 01/20/1998 Issued: 02/10/1998 *• kA•** k** kk**• k* 4•********** * * *k*k*•A *kk ***k** *k• **le A•k•AA*•k•k•k•* *•k•k Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the Tukwila Building Division. 2. All permits, inspection. records . ":and' approved plans shall be available at the job site prior to the start ";of., any con - struction. These.::ldocuments- are to be maintained and avail- able until final?`in pertion' approval, is granted.„' 3. All construction to be done, i'h' conformance 'w:ith approved plans and requirements of the Un itorm 'Bu i ld i ng Code Edition) as :amended Uniform Mechanical. Code 01994 Editi'on), and Washington State Energy Code (1994 Ed'it.ion) 4. Validity., of Permit. The i ssuahoe of a permit, or ;approva,l 'of ,.' plans, specifications, and computations shall not be < ' con -;,'`;' strued` ".to be ,a permit. for °, `. or an approval of, any violation of any the, of the, bu i l d i ng code or of any other ordinance, the jurisdiction.: No permit presuming' to .`'; give authority to violate or' cancel: the provisions of this code ;hall 6e valid.": S. MANUFACTURER'S INSTALLATION,INSTRU,C'TIUNS . REOUIRED ON SITE.' FOR THE BUILDING "INSPECTORS- REVIEW: ACTIVITY NUMBER M98 -0008 PROJECT NAME TACO TIME RESTAURANT DEPARTMENT: BUILDING DIVISION g FIRE PREVENTION C ING DIVISION El 4g - �� -9 IC WORKS UCTURAL ❑ PERMIT COORDINATOR iimg DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE XI COMMENTS REVIEWERS INITIAL REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED 0 t &lab PLAN REVIEW / ROUTI ' e SLIP NOT COMPLETE Q APPROVALS OR CORRECTIONS: (ten days) DATE DATE TUES /THURS ROUTING: PLEASE ROUTE F1 NO FURTHER REVIEW REQUIRED ED ROUTED BY STAFF u (If routed by staff, make copy to master file & enter Sierra.) APPROVED I I APPROVED W/ CONDITIONS a NOT APPROVED (attach comments) Q APPROVED W/ CDNDMONS p NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE C:ROUTE -F DATE 1 -20 -98 DUE DATE 1 -22 -98 NOT APPLICABLE 0 DUE DATE 2 -5 -98 • DUE DATE (Cenificaion of occupancy required. ) Project: 1 I t., Type of inspects ` 1 Address: / F2-0 I Gp sy Date 6 called: r Q s Special instructions: 4, 0 0..hel cy.",M, . --(1--- tktts> Date wanted: c -c/i3 a.m` p.m. Requester r i cue\ ° b '" g.c) voi INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: , tttrrInrrte. - .,t ) e y: -riiii INSPECTION RECOR Retain a copy with per Date: nig 8 --o ooS PERMIT NO. (206) 431 -3670 Corrections required prior to approval. fi $42.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Proje -f--; Type of in tion; /LL Address:) X 2_0 130 Date called ; I r 1 98 Special instructions: Date wante C ) � P.m. Requester ‘1/4/ P o eNo.: ' "' 770°1 INSPECT ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: INSPECTION RECOI Retain a copy with pe A Corrections required prior to approval. CAC . ( U PERMIT NO. (206) 431 -3670 El $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: '�i`� ���.v T..; tAr,l ' � I i :`�. �:i' r.. � �',; y :. �'i } dd i�; 1" irt!'�'1 • r {�.,. l, � r„�$'. S' .. '. r . ' t`, This Payment 99.69 Total Fees: Total ALL Pmts: Balance: • ; •. , ki ' b 0e r*'A *i****** ***k* *A**;;4+l/* *NA.k; kk; •kk *A *k* ** *6 6*k* *k *k6 1'Y OF 1`UKWtL.A, WA TRANBM3:1' r*• a•*: 1*•k 6A*' 6*A66* 4*' Akk*A***: 1•* IcAk• kn*k* IcA 'k *+k6*it6**'A4• *A*A RANSMIT Number: U9700711 Amount: 99.69 02/10/98 08:48 Payment Method: CHECK Notation: PACIFIC 5TAINLES Tn•it:. ULM Permit Not M98 -0000 Type: D- -MECH MECHANICAL PERMIT Parcel No: 362304 -9105 S i t e Address: 68220 a 1430 6T 9'.9.69 99.69 .00 fi**•A*0 *A00,4 *• A*0* k* A* 4 *** Ar•* MA* Abab/. *4A *ahAi *4k * *4A•ka*0k*kA*.A *** Account rode 000/345.830 000/322.100 Description Amount PLFi4'N CHECK - NONKE:i MECHANICAL- •- NONRCS 1:•1.94 79.7 "3 • - Underwriters Laboratories Inc. June 29, 1993 Vent -Matic Systems Inc. 3320 N. 29th Ave. Phoenix, AZ 85017 Vol. 1 File: MH12532 Project: - - -- Type: R Product: EXHAUST HOODS WITHOUT EXHAUST DAMPERS The following material resulting from the investigation under the above numbers is enclosed: Additional Section for Volume of Follow -Up Service Procedure. X Revised or new pages and illustration for Follow -Up Service Procedure: 1. Revised Pages 1, 2, 2B, 2D, 2C and 6, Section 1, issued 5- 10 -83. Please file *revised pages and illustrations in place of material of like identity. New material should be filed in its proper numerical order. Report: Report Revision: 2. Same as Item 1 above. Please review this material and report any inaccuracies to.MR. GENE WIRTH referring to the above project number. GW /AF:pt Encl. (Continued on Page 2) UNDERWRITERS LABORATORIES, :NC. Santa Cara. ,aulorr a c, 406) 985-2400 FAX No.1408)295 -2256 MCI Mall %a. 259 -3283 :able UL,t:C SANTA CLARA. RECEIVED TKtN11-k CM( ihti 2 0 1999 PERMIT CENTER :31.Un ...,:race AA dirk n#'„a C 'D E S C R I P T I O N File MH12532 Vol. 1 Sec. 1 Page 1 Issued: 5 -10-83 Revised: 6 -29 -93 PRODUCT COVERED: * Exhaust hoods without exhaust fire-dampers Models: CDI, CDW, CIV5 - @, CIV8 - @, COX, CRO, CSBS, CS :, CSO, CSW, CSWI, CWC - @, CWE - @, CWV - @, and ECO -CWE @. @ = Suffix BP or C or CBP GENERAL CHARACTER: These exhaust hood assemblies intended principally fcr use over restaurant type cooking equipment, such as ranges, broilers, deep fat fryers, grills, etc. The assemblies are factory -built units. INSTALLATION: Each exhaust hood shall be accompanied by installation instructions containing information as outlined by ILL. 9. MARKING: The marking attached to the front of each hood assembly includes the following information. 1. The Listing Mark of Underwriters Laboratories Inc. 2. Manufacturer's name and model designation. 3. The following statements: GW /AF:pt PS2- LIB /P.1 RECEIVED CITY OF TUIKWIIA JAN 2 01998 PERMIT CENTER Model File MH12532 Vol. 1 Sec. 1' *Page 2 Issued: 5-10-83 Revised: 6 -29 -93 GW /AF:ot PS2- LIB /P.3 Clearances TABLE I crows Maximum Front Lower Edge Side Overnang Front Overhang Cooking Surface Air Flow in Surface of Hood to of Hood to of Hood to Extended in Front CFM /r':. of Hoot Temperature Cooking Surface Cooking Surface Cooking Surface of Front Hood Edge Min. Max. °F Minimum Maximum Min. (In.) Mir.. !Ir..1 Maximum fIn.1 Exnaust Suat COX 600 24 30 12 14 NA 260 NA CSES 600 20 30 12 NA 5 -1/2 260 NA CRO 600 20 30 12 14 NA 250 NA CSC 600 20 30 12 14 NA 263 NA CSW 600 24 30 12 14 NA 250 NA CSW: 600 24 30 12 14 NA 260 N ?. CS: 600 38 48 12 14 NA 260 NA CO: 600 38 48 12 14 NA 26C NA COW 600 38 43 12 14 NA 260 NA CW3-3? 600 38 48 12 6 NA 260 200 -C 600 38 48 12 6 NA 250 23C -CEP 600 38 48 12 6 NA 250 160 CWV -BP 600 38 48. 1� 6 NA 250 2CC -C 600 38 48 12 6 NA 263 200 -35P 600 38 48 12 6 NA 260 160 2:V5 -5? 600 38 48 12 6 NA 263 230 -C 600 38 48 12 6 NA 260 230 -C.P 600 38 48 12 6 NA 250 160 C:V8 -E? 600 38 48 12 6. NA 260 200 -C 600 38 48 12 6 NA 260 200 -CBP 60C 38 48 12 6 NA 260 160 CWE -8P 600 38 48 12 6 NA 260 230 -C 600 38 48 12 6 NA 260 200 -CEP 600 38 48 12 6 NA 260 160 ECO- CWE -BP 600 38 48 12 6 NA 260 200 -C 600 38 48 12 6 NA 263 230 -OP 600 38 48 12 6 NA 263 160 CITY of TUKWILA JAN .2 n I-l� PERMIT CENTER It Dear Sir: City of Tukwila Fire Department Fire Department Review Control #M98 -0008 (510) January 23, 1998 Re: Taco Time Restaurant - 6820 South 180th Street The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. An approved automatic fire sprinkler extinguishing system is required for this project. (City Ordinance #1742) Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when the system is actuated. (UFC 1006) All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 2. Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 4404 • Fax (206) 575-4439 Page number 2 Yours truly, cc: TFD file ncd City of Tukwila Fire Department 3. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when the system is actuated. (UFC 1006) The Tukwila Fire Prevention Bureau John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 5754404 • Fax (206) 5754439 ' REGISTRATIONT NUMBER CCBG ...PACIFSP117B7 .11/15/1998 EFFECTIVE DATE , • . :0.1/27/1989 PACIFIC STAINLESS PRODUCTS INC 10100 SW ALLEN BLVD BEAVERTON OR 97005 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY BG 1)alath And 1)3tiplay t'cililirulr This is a copy of the original Business License for the year 1998 Signed this statement to be true on Lance H. Carleton V.P. Snohomish County Expires t - /5 ^ v2GU0 art MOWED WIIA FEB 1o1998 PERMIT CENTER M NOTCH NOOp =0R .•• vAPOR NOOD -- TY °E 2 UNIT OF • E %N. DUCT "- OF EX, DUCT MA DUCT TO K;T!HEN TYF, EX, ROOF FAN UNIT 7YF=E I +-+OOV NIOTEe - EX-'.. ROOF __. FAN UNIT �.�. MAKE -U° AIR UN!- '."O. CEILING DI, UNITS DUCT HEATER PARTIAL FLOOR / < ITOKEN / ROOF MECH. PLAN VIEW SECTION HOOD TO BE IR GA `,_. ALL- ,ELDEO.._ONS TRUET IOIC, ALL 101N7S AND SEAM; TE BE OFIJUIDD SHOO TH'. P 11,1E1 II 10 BE 18EA @AL.VANI?ED OR IE GA _. _ A,._ 1 ELDEE 1 ;REASE N> P_CIT1 14 FOR F HAIL � _IRE PAD= TO Ec. 1-.FT METAL ON : vrN,.AL 'r60'._ 'aTr: REIrrOREED •.�'. Tr. .iqF: ME :; H. 4 TYPE I EXHAUST LILI;_T ;HnF' TO BE 1 - HOUP HA@ r TED EONS: `ION j 5 STEEL :T'JD _ A. t - (PE ISYPSUM BOARD ONE LAYER ON riNE A44_8 fOjTT,IDE -.L.H TAHE _; JE:141 ANE SHAF' T BE SONTINUDUS FF.DM TOP OF HOOD ?D ROOF . A MINIMUM a• StEARANFE BE 1 IHF INSIDE ;HAFT VALL AND THE @PEASE ')UL T [S REQUIRED ON ALL ;IDES. THE GENERAL • :ON'PAC TL'R = HA;..L PPfl/ 1L. AND INSTALL ALL PENETPATioNLE. ;HAFTS PAIN EHO Ds A8 I ,EAT/EA. C. AN AEPRIVEL. . . .10 :' JPER4TCL, FIXED P*PE FIRE. SL PRESS :3`, i :,,Ei +. SHALL BE 11,S TAI. LLD JUEE SHE C1Xi 1,1 AREA P'RU ' DE 'JN:CEP SEPARc TE PERMIT BI A LIE EONTRAC TOF:. :7',ALS LIA C - HALL SLOPE TOWARD HOOD 1; 4• JNEA LEr +GT AND FT ALL ?tl' ELBOW'S AND :D• MIN SPACING ▪ T,PE : EKHALiS' krjupp AND DL"_i" TO HATE A ML IM: =., ;'L=AF'ANCE F POM IOMB:-T13LE '. A LC-.]I • :FE I Pi OUT LE El BE MINIMUM OF -IV 30,E. T =OG' - F POUF ' A_E AvU .� i' TROr r I.. SIP lNtA. THE F /HAL;',:" AND MAKE')," Alp S4". TENT - /LL BE TONNEC TED B` AN -__CTRiC L. :N ERLOCR1h'E E. E'. ":CA_ .ET Oi HEF ; HEF ERENOE ': ELECTRICAL DRA'JINGS M. EXHALES' HOOD GREASE FILTERS AND LIGHT FIXTUR 10 BE UL LISTED 'JNSTRUC'[ON OF EH,HAUS" 7, HOODS AND DJ[T TO CONFORM 13 NEPA A96 - I99a EDITION. 13 T`"E ELEC. TRICA. EONTRACTIOR 'SHALL MAKE ALL APPJr ABLE C 'NNEC TINS F DR, PROFEP @PERAE1ON OF ALL STEMS 4 THE __NEPAL coNTRACTUR SHALL ✓ERIFV ALL DIMENSION` PEI f ORE EONS 'PUCT.ON Lir RENE :,NE EOLSAD1NATE ?I ._ -L HAUSE SYSTEM N'EGUIREMEL , "n 15 T-AE FLECTktCAL CON TRAC _HALL ;LOCATE ALL E PICAS EDNNEC " IONS FOR EACH EAN MOTE' - EA:H EAN TAE EC. ONT,ACTOP `HAUL /PEL' ALL - -EAL o`Jr : {C'` AND HAG ;;TAR '/E EXHA@ST AND MA, ? AIR - "F COVERE' F +' A ONE ;EAR 'A. , AND SAKE •./AFc4t :.. FE,G, THE DA,: _TART ; PK]' IDET. A 0 SER I.. COMP„ AERFEIP.1NG REGULAR FIE TER ELEA8IINE „,. MA;NTENAI,CF JEIr Al BE PR :, 1'_D T�.IS vARRANIY LS •i GIL IF NO SERVICE r,: P.._8 'PERFORMED AFTER NI 111 ;o_; L _; r''u" i '.SIP .TAR' END OF WALL. /EN? MATIC CSBS UL EX --RUST -+00 ^v TYRE I" IS' EX,H. DUCT 21 "x10" EA{FOSED AREA 5/5_ 3/4' . 1 - 0" SCALE DUCT SIZE • 12 , -- -DUCT SIZE • �. I !DUCT &-HAFT SECTION NTS - SCALE 4 cook tins equ.p- --- steers kettle souio ELEV. of EX4 -4. OCD AREA SEAL 4LL C�4T5 M GYP. icti e4,01) W! CYFStPT ANA TAPE •( L: Inge' 1 E I tG� �-- 1'.�L \'�-� \ , 16 G4 GAL V THY P ATE LLELD TO OUL'T I h - . FIRE PAD W/ ROCK WOOL INSUL. 5/5 22 GA. FLUTED IS" AROUND DUCT AND E' /•N. HOOD TO 2, /J A5OVE FLOOR LINE // HOLD TO TOP CIF CUT CANT STRIP ATTACHED TO EXTER»OR WALL E ROCS 11" STEEL SllDS a le• C.C. ACT ROOF CURB ADAPTER B. GAL V. VIE *AL CLOSER K)T BY ABP. SELL i0 FILE COPY I undA A'A Ad that the Plan Check I, a:a subject to errors and omissions and of plans does not authafal b Violation of any adapted code or ad.11111 .� contractors copy of Permit M1f5- 000$ CEILING LINE SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ELECTRICAL ❑ PLUMBING CI GAS PIPING CITY OF TUKWILA BUILDING DIVISION _ • /A °OR CANOPY _ EXHAUST , -OOD T" °E 2 ;NOTCH RIGHT REAR SIDE; 5/5 ;a_1_ 'FLASHING FRO" OF iJOCD TO '7" OFF FLOOR =LUTEC ;_OCR EIN= M40- oa0 $ AP'RG( :0 rE3 03 19.93 RECEIVED CFfY OF TUKWILA JAN 2 0 1998 PERMIT CENTER LEO 0 KY? 0 C 0 0) L0 (0 0) Q V 3 0. a. 0 III ill I- 0 w v Z rn w n U in ° Z W 1 Q - F- 3 I— z 0L C Z a 0 NOTE: MAINTAIN A CLEARANCE FROM COMBUSTIBLE MATERIALS OF NOT LESS THEN !A" INCHES FROM THE HOOD THIS MAY BE REDUCED TO NOT LESS THEN 3" INCHES PROVIDED THE COMBUSTIBLE MATERIAL IS PROTECTED WITH ONE , -10:1R RATED MATERIAL (Uric SEC. 20034 'REF. TO ARCH. DRAWINGS) PHOENIX MAKE UP AIR SUPPLY FAN UNIT MODEL HM -6800 SIDE DISCHARGE 3 /4 -HP - 115, - 1 9 3400 CPA ®.5" SP - WT. 181 LBS. - NOTE: (� OUTSIDE AIR FOR A HEATING SYSTEM SHALL 1 FROM AN APPLIANCE VENT OUTLET, UNLESS THE OUTLET IS 3 FEET ABOVE THE OUTSIDE AIR INLET. UMC 317.6 ROOF LINE TEMP. AIR TC SUPPLY AIR. DIFFUSER FOR KITCHEN AREA 1 2 MIN. Mq ca& 1- — CEILING LINE A WET CHEMICAL EXTINGUISHING SYSTEM WILL , ESE PRO` /IDED FOR ALL CLASS I HOODS AND WILL COM TO TAE UMG SEC. 2004. FIRE DEPARTMENT AND FIELD INSPECTION BY: THE LOCAL JURISDICTION FIRE EXTINGUISHING SYSTEM CONTRACTOR WILL PROVIDED DETAILED DRAWINGS AND SPECIFICAT,OI, TO THE LOCAL JURISDICTION FOR REVIEW MODINE DUCT FURNACE AIR SUPPLY FAN UNIT MODEL MEG 200 - BTU 200.000 W/ 115, CONTROLS - 43F - GAS METH. MODULATION OHM — - FT 219 LES. - C" MIN . FL OCR N. T. S. SCALE MIN DIS. DIS. TO ADJACENT OAT SIDE .L L_ LOREN COOK FAN /UP -BLAST MODEL -ACRU 135R 35 i " 115 V - 1 Q -- OEM 1005 - WT. 82 LBS. - C DUCT 45 SID SECTION VIEW DUCTS ON ROOF SHALL BE THERMALLY INSULATED TO PROVIDE A MINIMUM OF 5 -7 13.0 INCH 0.75 LB /CU.FT MINERAL OR GLASS FIBER BLANKET, 2.0 INCH 10 TO 3.0 LB /CU.FT. DUCT LINER, MINERAL OR GLASS FIBER BLANKET, 2.0 INCH 3.0 TO 7.0 LB /CU.FT. MINERAL OR GLASS FIBER BOARD OR EQUIV- ALENT TO PROVIDE AN INSTALLED TOTAL THERMAL RESISTANCE OF AT LEAST R -7. MAIN TRUNK DUCT DROP TEMP MAKE -UP AIR SUPPLY =L E DUCT - TEMP. AIR DUCT W; !` INSUL. L IVE ROOF OVERHANG OUT SIDE AREA � — 48 "xe - `.1 2 CANOPY STYLE DISHiJASHER / POR E H. HOOD \ ROOF PENETRATION WATER TIGHT LEVEL CURB/ FLASHING by others // � 1' 6" MIN. DI5. TO ADJACENT AIR INLOTS 21 (REF. TO ARCH. DRAIINGS) ROOF PENETRATION WATER TIGHT LEVEL CURB/ FLASHING by others ROOF AREA EXPOSED GREASE DUCT SYSTEMS SERVING A TYPE -I HOOD SHALL HAVE A CLEARANCE FROM UN- PROTECTED COMBUSTIBLE CON- STRUCTION OF AT LEAST I8 - INCHES. THIS CLEARANCE MAY BE REDUCED i f TO NOT LESS THAN 3- INCHES, PROV- IDED THE COMBUSTIBLE CONTST- RUCTION IS PROTECTED WITH MAT- ERIAL REQUIRED FOR ONE -HOUR FIRE RESISTIVE CONSTRUCTION. UMC 507.10 LOREN COOK EXHAUST FAN UP- BLAST UL LISTED MODEL VCR180 V68 - 3/4 HP 115v 1 0 - 2400 CEM 1"SP 1046 RPM •- WT. 131 40"- MIN. DIS. TYPICAL GREASE OUTLET o SA L FLOCK LINE 24" -MIN. DIN RATED DUCT SHAFT CONSTRUCT1O0J W/ NON COMBUSTIBLE MATERIAL FIRE.R.TTED ENCLOSURE by othsra. MAKE -UP AIR RAN TO ((REF. TO ARCH DRAWINGS). SL'IzL`" AIR DIFFUSER FOR KITCHEN AREA - - --) CEILING LINE VENT -MATIC UL LISTED CSBS BACK DRAFT STYLE TYPE I EXHAUST HOOD SYSTEM 3)4" t 1' -0" SCALE 5' -MN. DNS. TO ADJACENT OUT SIDE WALL VENTED ROOF JACK .by P.S.P. AIR SPACE MAT -!TAIN MIN. 3" TO MAx. I2' CLEARANCE ON ALL SIDES OF DUCT TYPICAL, ALL GREASE DUCT SHAFT INCLOSERS TO BE SIZE AS NOTED AIR SPACE MAINTAIN MIN -6" CLEARANCE 1 — ALL AROUND DUCT DUCT 5HAFT CLOSURE 16 GA. Fr. FIRE PAD W' ROCK WOOL INSUL, 5/5 22 GA. FLUTED 16" AROUND EXH. WOOD TOP /SIDES /BOTTOM cook. — SIDE SECTION VIEW cp ROOF OVERHANNG, B OUT SIDE AREA AIR SPACE W/ WALL FRAME TYP N N EXHAUST DUCT REQUIRED GREASE' CLEANOUT ACCESS PANEL -DOORS TO BE PROVIDED AT THE PROPER LOCATIONS DUCTWORK TO BE ALL WELDED CONSTRICTION LICUID 1 AIR TIGHT CONTINUOUS by PEP 01)0 OF TUKWIILA AFF FEB i) i E B V ( J 1 2 ROFEIVED CITY OF TUKWILq JAN 2 0 1998 PERMIT CENTER 0 07 Q) 0 0 Q) Q) 10 Q) 4 0 0 0 U EL U 0 Q) U u 0 W 8 U x' Q W ' c M am 4 8 O ~ a b a) B B B IF