HomeMy WebLinkAboutPermit M98-0010 - SOUTHCENTER MALL - ORANGE JULIUSORANGE JULIUS M98-0010 City of Tukwila C Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0010 Type: B -MECH Category: NRES Address: 896 SOUTHCENTER MALL Location: Parcel #: 262304 -9004 Contractor License No: HEATT * *206Q0 MECHANICAL PERMIT TENANT ORANGE JULIUS 896 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT TOM MCCLOSKY Phone: 425 885 -3247 PO BOX 1268, CARNATION WA 98014 CONTRACTOR HEATTRANSFER COMPANY PO BOX 1268, CARNATION WA 98014 ******************,************************** * * * * * * * * * * * * * * ** * * * * * * * * * * * * ** Permit Description: REWORK EXISTING DUCT.WORK AND DIFFUSERS, INSTALL. CUSTOMER SUPPLIED EXHAUST'FAN AND HOOD AND CONNECT WALK -IN COOLER REFRIGERATION. UMC Edition: 1994 . Valuation: Total Permit Fee: * * *" * * * ** * * ** ***************************. * * * * * * * ** * * * * * * * * * * * * ** * * * * * * ** Pe it enter Authorized Signature Date I hereby certify that I have read and examined this perm.it.and'know the same to be, true and correct. All provisions of law and ordinance.'s: governing this work will be complied with, whether specified. herein or not. The granting of this permit does not, presume to give authority to violate or cancel the provisions of any other state or. local laws regulating construction or the performance of work. I.am authorized to sign for and obtain this building permit. Print Name:_ Signature: 7 5. � le (206) 431 -3670 Status: ISSUED Issued: 01/30/1998 Expires: 07/29/1998 Phone: 425 885 -3247 Date: ___ Title: 1.. /lei gt4_ 000.00 54.69 This permit shall become null and'.void:i.f thework is not commenced within. 180 days from the date of issuance,: orAf''the work is suspended or abandoned for a period of 180 days from the last inspection. Project Nameffenant: ` C�i'�.t/ l /c%s „5 6) Value of Construction: Z ■ Above Ground Tanks ■ Antennas /Satellite Dishes ❑ Demolition ❑ Fence ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting orb --_ Site Address: ?r? S7 �� � , r > Z-- ak" a .,5 _ _� / ! / q ty) e/Zl'p , (-� r j,� �/ �/ lam .4 (, Tax el er; _ q 00 V Phone:Ll/ C� 0/6 ^ j ^ i l Property Owner /C [C�t Street -- .7 4.4 c .ed e•/ , ‘,( City State /Zip: f 1 /v;" -.rz Fax #: .2/6 - - 2- Contac son: 9J 0 Metro Pho_ne: _ Street A dress: City State /Zip: Fax #: 5-3 Contractor: 4- - _ P 477 . 5 - z 547-- Street Addre OP City State /Zip: t Fax : Fax if: 333 -(fl - Architect• `L Phone: Street Address: ,- LiJ - . e r rr/ /1 • City S ate /Zip: Fax #: 20 -00 6 Engineer: Phone: Street Address: City State /Zip: MISCELLANEOUS PERMIT'REVIEW AND APPROVAL REQUESTED:, (TO BE FILLED OUT. BY APPLICANT) Description of work to be done: , e.--wpc1C.' X,fF/ : / ri / .J/0/04 - - A '.. ' . /.I .. a . 44 ,L. /IV cGD . , i.r. Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and stera.e location on so.arate 8 1/2 X 11 •a•er indicatin• •uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ❑ Demolition ❑ Fence ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting ■ Bulkhead /Docks ■ Commercial Reroof Mechanical ❑ Manufactured Housing- Replacement only Temporary Pedestrian Protection /Exit Systems MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application APPLICANT REQUEST.. FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # El Water Meter /Permanent # ❑ Water Meter Temp # El Miscellaneous ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s)* ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing El Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: CITY OF(UKWILA Permit Center" 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: MISCPMT.DOC 7/11/96 Date application expires: ApplIca /2 take�y: (initials) • Signature: t ✓/ Date: Alpir2 0 ' hon =y Submit checklist No M - Print name. A e i / e G Address: • 4•2_,.. .-.i i rte.! • Zio At. . ALL MISCELLANEOUS PE - APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING: ALL DRAWINGS, SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANTS AND UTILITY PLANS ARE TO BE COMBINED ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building; Owner /Authorized Agent. If the applicant is other than the. owner, registered a rchltect/engineer, ; or. contractor licensed by the State of. Washington, a notarized letter from the property owner authorizing the, agent to submit this permit: application. and _. obtain the permit will be required as part of this'submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground TanksfWater Tanks - Supported directly;upon grade exceeding 5,000 gallons and a ratio of height to diameter: or width which exceeds 2:1 PERMIT REVIEW Submit checklist' No M -9 0 Antennas /Satellite Dishes Submit checklist No M - ® Awnings /Canopies - No.signage Commercial Tenant Improvement Permit .: 71 Bulkhead /Dock Submit checklist . No:, M -10 El Commercial Reroof. Submit checklist :. No: M -6 71 Demolition Submit checklist No M -3; )M -3a 0 Fences - Over 6 feet in :Height Submit checklist • No: M - 9 ri Land Altering/Grading /Preloads Submit checklist No: M - 2 Q Loading Docks Commercial Tenant Improvement Permit: :. Submit checklist No: H -.17 0 Mechanical (Residential & Commercial) Submit checklist : No M -8, Residential only - H- 6,,H -16 ri Miscellaneous Public Works Permits Submit checklist No : H - 9 71 Manufactured Housing:(RED INSIGNIA•ONLY) 'Submit checklist No M =5. to Moving Oversized Load /Hauling Submit checklist No M - 5 O Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following. exception: If.roof structure. to be repaired or replaced A Residential, Building Permit Submit :checklist.: • No:. M -6 0 Retaining Walls - Over 4 feet in height Submit checklist No M -1 ci Temporary Facilities Submit checklist No M -7 in Temporary' Pedestrian Protection/Exit Systems ,Submit checklist : No M 0 Tree Cutting Submit checklist , No M -2 ALL MISCELLANEOUS PE - APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING: ALL DRAWINGS, SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANTS AND UTILITY PLANS ARE TO BE COMBINED ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building; Owner /Authorized Agent. If the applicant is other than the. owner, registered a rchltect/engineer, ; or. contractor licensed by the State of. Washington, a notarized letter from the property owner authorizing the, agent to submit this permit: application. and _. obtain the permit will be required as part of this'submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 CITY Address: 896 SOUTHCENTER MALL Permit No: M98-0010 Suite: Tenant: ORANGE JULIUS. Status: ISSUED Type : B-MECH Applied: 01/21/1998 Parcel #: 262304-9004 Issued: 01/30/1998 ********k***k**********k****k***k*kk*********41****Vickk*Mk*****h****k*kit***k Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and thp„Tukwila_Building Division. 2. All permits, inspection reVord plans shall be available at the Jobisit6-4)rfOr to - 66 - itof any con- struction. These documents are tojie maintained and avail- able until finalInSpectionapp gr,onted 3. All construot0h to ,be done iWconformanceith a0prtOyed plans and rkufremenps of the UniformBuildfng .Code (1994 Edition) as, Mechanical Code (1994 Edition) and Washington State Energy code J1994 Edit,ion)':, ; 4. Validit.0 Permit. The iss0a664' a permit ,, ,or approval of plans,/,tpecifications, andcpmputations shall not. be strued,.,to,be permit for or an approval of any vipla'tion9 of any of the provisioWs of the building code or of enk other-Ordinance,of the' No permit presumq)§ to give authority ,to violate. or cancel the provisions of this codeyshall be valid: 5. MANUFACTURERS INSTALLATION INSTRUCTIQNS,REQUIRED ON ASITE, FOR INSPECTORS REVIEW. 6. PluMtOng Rermits,,shall Otainektibrvugh-the Seattle-png County DepartMent,,of.P0110fealth. JPlumbihg will be :inspected by that'agency, gat piping L (294722),...' - 7. Eled:ofileeK:,peemitS shall he obtained, the Wet tate:AiO:sibn ot Labor and InduStrtes, 'and-all.,telectric4b work . 011 . :be ,inspected by that a0,010 (?48,600).,,„ ' t OF TUKWILA. 11° • , v. ; • • —• • ' • • : • ; • • ACTIVITY NUMBER PROJECT NAME I PARTMENT: P I ING DIVISION El kak-% Q i\dp( REVIEWERS INITIAL REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS INITIAL C:ROUTE -F Foiwt4+ Ccoia. Cori PLAN REVIEW / ROUTING SLIP M98 -0010 ORANGE JULIUS DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE ❑ NOT COMPLETE Q COMMENTS APPROVALS OR CORRECTIONS: (ten days) FIRE REVENTI8N P 'G DIVISION 0 PE TT RIPOORDINATOR tkfr...; , TUES /THURS ROUTING: PLEASE ROUTE I 1 NO FURTHER REVIEW REQUIRED 0 ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) DATE DATE 1 -21 -98 DUE DATE 1 -22 -98 NOT APPLICABLE Ei DATE DATE DUE DATE 2 -5 -98 APPROVED 11 APPROVED W/ CONDTTIONS ❑ . NOT APPROVED (attach comments) fl DUE DATE APPROVED t l APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 (Cettifcadoe of occupancy required. ..• • . • _ . • - • -,-;- ' • • - - - • - -• • - -" , _ • - • ••• . . . • . • . • . . . . . • • . _ • ', ......... • - ..... -' - "- . •. • ... • . ,. . . • . • -. . .-_:•--: .• _ , ..._ ----- -•-:-;./::::."-.::::;"::•- - - - .•:. . • . • . . • • • ■-• !!! 4-!!,!,‘1,-,!,, A • 1„ r-!• • •!' ',;t' '7%, .'• . . ris* ITY OF TUKWILA, WA . TRANSMIT TRANSMIT Number: R9700707 Amount: 54..69, 01/30/98 13:41 • - Payment Method: CHECK Natation: HEAITRANSFER CO In it: BLH. Permit No: M98-0010 Type: 0--MECH MECHANICAL PERMIT • Parcel Nat 262304-9004 Site Address: 896 SOUTHCENTER MALL TotarFees: 54,69 This Payment 54.69 Total ALL Pmts: : 54.69 . *40, Account Code Description • Amount', 000/345.830 PLAN CHECK - NONRES . . 10.94 000/322.100 MECHANICAL - NONRE .43:.75 'Vt!, fit 4 1V , ,e6i P. 47 .'csi 4 Kj Project: ,,.‘ urec -....la t i Cc. Type of in . ect , - Address: al4e, SC.-- Mall Date call- , Special instructions: Date wanted: OA a.m. (lir_ Requester PI INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 E:r_6pproved per applicable codes. COMMENT INSPECTION RECORD,„,„ Retain a copy with peal, hich3...footc) PERMIT NO. -206) 431-3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: Project ,retki. t (sue Type of insp l Date called: 1,2 Addrest _ s (Thad ' ( t a Special instructions: Date wanted a.m. Requester: Cr. i POnet.... 707 COMMENTS: Inspector: I Receipt No.: INSPECT ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 11100, Tukwila, WA 98188 Approved per applicable codes. I g7,e, / t),„,ee INSPECTION RECORD Retain a copy with peril wl Corrections required prior to approval. (92_ 7 cJ2 rigs -oot PERMIT NO. (206) 431 -3670 Date: / . .404 $42. ' REINSPECTION FE - ' REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: 1 . fy (A rJt 2) d+ - -S Ri+•G€' m uST 6- /N7*1:- t- ocic - w TOE' % ■Q r ,S- rt> (J / (e" IS 11"/ V'' i T F r n.) pN v,o-ii C rr t �---i �i f �c� . v v'' -s'e'" o trn C.. $ I I.2- . 4 0 Y1 q ) r I1..,.. a.r r4V sP.Ez..s c�, ti �vt ,- w . ....- Gk.-. Project: CJ (;4,4. Type of I?spe'tion: , J .. 6,,ruT k. t', Date called ) . /Z AddrP5 ` ,L, A l t� �} v"'( Special instructions: Date wanted: ^, a.m. '--� 18 p.m Requester: 9 Phone o.: M,.. (9 A- iad,o- 707q 0 I Inspector: I I Receipt No.: INSPECTION RECORD Retain a copy with per INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 V-0010 PERMIT NO. 206) 431 -3670 n Approved per applicable codes. j Corrections required prior to approval. Date: 3 ,, Acy , $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project* - _ G.M .,� i a Ty li e . inspec ion: �1... , L � Address: 0 1 _ WNW called_ 69 / Special instructions: .ma ! - . c 4t. !&."4. .--rt. e 9 !3 a-m. Date wante : a. Requester: /J L JI i : Ph ne o.. 025.3. Lao..7O7 q r� INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: 1 INSPECTION HECOR Retain a copy with per PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must . be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: y s Receipt No.: Date: COMMENTS: Type of insppctio : p 1 e, fA v (0E l -(art— A 1L. Floc No; 1 Date called: I_ t~ Su Poki. t140 A.---A . Date wanted: q � 7 35'to p.m. c AP 14Di.0 1 S v.() PI 7 L0-s tam . Phone No.: L eas .8X. -,1: { pill C.- �� Cry 0 LINT 1�.A.t� ..�'ct_ s S I k) ‘4111,43 . -€ c s -1.P \ -:1 c. -c .a i -rn i -kw P-4%6 k " e . Ali VI. r 1 A; 7141.1 -p ri'c - 5 4 r Project: - Type of insppctio : p 1 e, Add f Date called: I_ t~ Special instructions: Date wanted: q � 7 35'to p.m. Requester: -� ° �C..l L 1'.G .4? cf Phone No.: L eas .8X. -,1: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: f INSPECTION RECORD Retain a copy with per 1 Date : / M13 -op so PERMIT NO. (206) 431 -3670 Approved per applicable codes. J1 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 .Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Projec �- � ,y� J� Type of i spedYon: 1,0..1,�.., I L) i t,,,,rr : Address: ate called: Special instructions: e' / ._253 - 2( a-1 c. Date wanted: t a.m. Requester: c 2,cu Phone No.: Ere X 5 5 - (oC ici/Y CO MENTS: INSPECTION NO. Approved per applicable codes. I Receipt No.: INSPECTION RECOR Retain a copy with pernLJ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 a /27. Date: PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Inspector Ira-NW id Al I 4 A Date) $42.00 INSPECTI PEE EDUIRED. Prior to Inspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. { Project Name Address 940 p91 Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: __1 Halon: Monitor: Pre-Fire: A/ Permits: City of Tukwila Fire Department Thomas P. Keefe, Fire Chief ••. TURWILA FIRLDEPARTMENT FINAL APPROVAL FORM Permit, No. John W. Rants, Mayor Suite # Authorized Signature . FINALAPP.FRM Headquarters Station: 444 Andover Park East TicAmWa Woldneop 98188 • Phone: gov 575404 ■ Pa gov 5n74439 ate •!' C City of Tukwila Fire Department Fire Department Review Control #M98 -0010 (510) Re: Orange Julius /Dairy Queen •- 896 Southcenter Mall, Suite #B Dear Sir: January 23, 1998 The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when the system is actuated. (UFC 1006) A sodium bicarbonate or potassium bicarbonate dry - chemical -type portable fire extinguisher having a minimum rating of 40 -B shall be installed within 30 feet (9144 mm) of commercial food heat - processing equipment, as measured along an unobstructed path of travel. (UFC 1006.2.7) 2. An approved automatic fire sprinkler extinguishing system is required for this project. (City Ordinance #1742) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 C City of Tukwila Page number 2 Fire Department Thomas P. Keefe, Fire Chief All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 4. H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFO 1001.3) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 6. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) .57. 54404 • Fax (206) 575 4439 Page number 3 day as needed. C City of Tukwila Fire Department 7. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fati• (206) 575.443 LEGEND SYMBOL DESCRIPTION DUPLEX OUTLET (D -O.) 120 V-60 -1 PH D D= DEDICATED CIRCUIT FOUR PLEX - r 120 V-60 -) PH 1 -BOX CONFIRM CONNECT O WITH MANUF. SPECS &JOR PULL & INTERCONNECT. SECURITY MONITOR 4 GAS POINT OF CONNECT : ' 208V CONNECT VERIFY PLUG CONFIGURATION' SV,SIFR. SPECS. HOT WATER CONNECT COLD WATER CONNECT • WASTE. DIRECT • CONNECTION I WASTE: INDIRECT \ VI CONNECTION 0 FLOOR SINK (.P PHONE LINE 0 M MODEM F FAX LINE ( FINAL POINT OF CONNECTION P4Ci G,16-I 2 4 ?37 (red IMF' • 32W YRIIPpIr JR s t 12ert,i0/ P f tLNI ag poi e QTI DESCRIPTION MFR MODEL,' SUPPLIER 1 3 ea Poll or Sales Cash Reg IDO 5100 Own /IDO 2 6 ea Ble.ers IDO EN,. 91010 Ex.., 3 1 ea Drop m,e fin 20, R Mall ' 9Y_8SCA RSC 3A 2 ea Drop in ice 11 K24 Randall : 9718SCA RSC 4 1 e Condiment dispenser Wu.er Ba WB- CD.IJ -MT 5 . 2 ea Co men dspenser TBD Ver w /Own - 0 MSC 6 lea Sneeze guard Tara I. . Quote OWN/P,SC Note see elevations 1 lot Front counter Custom 19 fin. h e/- 8 2 ea Blizzard machines 300/100 12c 13A 14 15 16 1 urn Glycol system lea D Rarnd i nk to non 1 e Dipper stand ko left a Food wanners 1 ea TOPpmf Cabinet free. This line r,1 used Thts line not used 18 This line nM used 19 This line not used 20 1 lot Sine counter Metro or eq 10 I1n: h l� RSC /GC 21 1 ea Soda d sp (by purveyor) Saco FFC132123 OWWPURV. MECHANICAL HN' CIS WASTE HN. a.f.f BTU. up 24' 1 -12' vent vent ELECTRICAL VOLTS PII HP AMPS. K 120 1 RF xf.f. 0 24 up N' • 15 •/- up 36' confirm confirm up 24• Cold Zone IW IDD ' IDO DOFC -5A 132003 132003 Confirm ORTCF RSC /IDO 20 115 115 110' 120 120 208 120 120 120 1 /4hp 1 /dhp 2 hp 31.8 07 0.35 0.35 24 24 >6' confirm REMARKS Phone connects to POS Drain. R sink . or nub drain plan Drain to floor. sink or hub drain near. see plan No power C required, conftrm wrowner if control is add.: Ih 110V 2 amp Pmver conned wounl be rer Venfy al out d Sneeze guard to be mounted to counter lop 3M adhesive by General contractor See details 8 elevations Reuse ex.. eq. from warehouse Verify eq. requirements w/Owner poor to stub ups Rolled edges v. shelf below. GC to col to handsink on site. Water cooled. dram 10 floor sink bola" by GC Mix pump to be local. inside walk in refer. confirm height 8 location w /owner. Locale una on roof. Provide power to roof Wdh counter top units list. below With counter top units I.ed tebw Counter top ones (2 ea dip shrill Wan P tarn top See delay 2 /AS. similar v. cut-out ecenornern install by GC Drain to flour sink Orange Julius- Spulhcehler 9 This line not used 10 Thls line not used 11 1 ea Stainless steel work tab! Duke or eq, 24x36 RSC ylon DI1515 GC 3/8 3/e 12 2 ea Soll serve ice cream IDO 957R wale/ cool 1/2 12a 1 Ion Cimmone dispensers Duke or eq. 141301 RSCIIDO 120 lot Mix pump Smelling Conlin w/owne RSCRDO w/nandsink 8 faucet 21A 1 ea Carbon., (by purveyor wldnnk system 921 M90-0010 PURV 12' uo 24' 120 1 (-L& L -- vc'_ -rK- Y/ LU Wr - '�. /r_.L'•G� TI - �f�l � I.1 ! > ta '<• , /e ( ✓lTT -e -5iTRU E'( Fib f• i�l' NJ C)%'ei. b • S 1r% •.4-%� � ^�t4G P 1 p n — Cr 1,Ei ( +T . Gill- J.tiFf JIk2Ll - (EVJ Us I I ca r 14 I �.. l ice, 1 �.., 4 lf,4e ti r 18 Or c�rs`-6 - >=vP • IQTV DESCRIPTION'. PIER' MODEL. 22 tea. Sanowiche prep lable Silver King 23 1 ea. Food prep Nnk wldrain b Duke or eq 24 1 ea Bun steamer Neamer Ernberglo 25 1 ea Secumy monitor By ovirner 26 19.4. C!_ - S Fief 27 This line not used 28 1 ea Table lop freezer Silver Kin. 29 ea Fryer Frynaster Mier dumpstalion 2. 1 ea Heal lamp By owner 30 to SKUCF -7 FMHSOBLSC eery E' rag Exist. SKSB -48-8 RSC SUPPLIER 11W CW'WASTE RSC 1/4' xtsli. , venly existing vent, CQ RSC 1/4• MECHANICAL 1 5 Hz. xrl BTU• VOLTSIPh 120 120 120 120 115 IIP 1 /4hp 1 /4hp RSC Own 31 1 lot ] 2 1 ea 3 ] 1 ea F i Hood 68 - X42 X24 Thermal Exhaust Products. Capture jet w/ speed con col Mix Ulu system Cornelius Wall shell for 4/33824 Metro Existing St H 10, roller aria Under n era5nwasn Hoban TBS Dayton RUE, K -B Glycol system 2d - x 48• 255 LX30H Verif Dt15t5 Metro or eq Etas. ref Vent Scotsman existing vent, Scotsman eta., vent, Everpure CC71 -MC Ivan To be setae Purveyor 30 Duke or eq. Vent' ist. vent, AOS n a 70. gal. Verdy existing verity Verif y existing. verily Metro or eq 6y owner By owner TBD TBD OwNGCIRSC RSC RSC /GC Existing RSC GC GC RSC /GC 1? 318' Existing Etas, RSV. c2 36 36A 37 38A 1 ea 39 1 ea 40 1 ea 41 1 ea St SII Work lane :ert'L,.1K1' a Washers arcombo ¢a HOt water lank gas 42 43 48 1 lot 1 ea 1 ea l ea lea 2C+ H M sink 8 counter Metro base wIP lam counter lop Wire shelves Ice Machine Ice Bin Water finer. system Bad in box system Floor mounted vino sink 3 comp sink Wall mounted Shelf Sale File cabinet Walk In freezer /refer 4.5 In drain 12 P.SC /OWN 3/4 1/2 3/8 1 1/2 12 See NOM 12" 80K ELECTRICAL 120 120 120 120 120 120 120120 208 120 exMino verily exists,. verily 170 1 12020 s 266 I 12020 3 1 /4hp 013 3/dnp AMPS Isw 15 sD 15kw 123 wads 1.7kw Het. id.f. c o nfum -2S 2 -04 ;osse rEH 60- vent ,ta i rnCM 318 REMARKS WM faucet '... Mormon ca. - :confirm interconnect Finermagic I" gas conned St .1w /basket Mt GC to install Et balance HVAC See sheet M/E l for details 6 sizing. See sheet A.4 for hood shad section GC to word. fnvaa per mfr recommendations. GC to provide blocking in wall 8 install sneNes Hi. temp. with booster Venfy existing 8 install height with faucet Similar to dot. 2 /A5 con firm GC to reoasnion per owners direction. Confirm pants of connect 8 remote Glyco sys. Drain to floor sink GC mstafi. Drain to floor sink. ve shelf below VAIK Direct connect GC to provide Nock. in wag Compressor on roof. w/ I weather i to/.7 :u 2" 1/4' Cora drain to flop sink below me a e(Y ch. ¢ I 4 " • (2) a-fj ccu r' - - CG Ed LO C V J COU e� r D F L 2 w ( I Mcl�r1 ,. Pod 4U" _ �+ 22 Y N NOTE. ITEMS #12 SOFT SERVE rA ITEM -- #38 ICE MACHINE TO BE ON REMOTE GLYCO r*2 SYSTEM. CONFIRM ALL REQUIREMENTS W/ 0- ' MANUFACTURERS SPECIFICATIONS. 4 3 {� " C -00I )7I,r cuae�ti� 1 CCU 7 FILE C r:lt r •t? n T. f ,.. ^: SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ELECTRICAL ❑ PLUMBING 0 G sS PIPING CITY OF TUKWILA BUILDING DIVISION THE MEDICI CONSULTANTS 410 Bellevue Way SE, Suite 201 Bellevue, Washington 98004 Tel: (206) 453 -9298 Fax: 453-0058 Sev U • l c, '1"7- ju uus/ Drawn By: EF Checked By Owner Approval: fir/- //s .v /i./ 4 '7 Co z4 A- 1 %- ` �� /O s- t1 ;.F3 sA i JST ,�pPRO�F� JAN 2 8 1998 gD LDIPJG DNISION - 1 Pr feel No' C1- t ' � GJTL���F- l -('�t D.R: i-2 •'',T This drawing is the exclusive property of The Modiei Consult. , and on be reproduced only wish the permission of the Architect. %nations and Modification 55 work shown en this drawings shall not be carried on without written permission from the Architect _ - - r 7E 1 / , / E } ° ' L ^ 71 �_ ; vi v D a, � I : ' _ I \ VI % ! V ( = V 1 ezw -t-/ P4Ci G,16-I 2 4 ?37 (red IMF' • 32W YRIIPpIr JR s t 12ert,i0/ P f tLNI ag poi e QTI DESCRIPTION MFR MODEL,' SUPPLIER 1 3 ea Poll or Sales Cash Reg IDO 5100 Own /IDO 2 6 ea Ble.ers IDO EN,. 91010 Ex.., 3 1 ea Drop m,e fin 20, R Mall ' 9Y_8SCA RSC 3A 2 ea Drop in ice 11 K24 Randall : 9718SCA RSC 4 1 e Condiment dispenser Wu.er Ba WB- CD.IJ -MT 5 . 2 ea Co men dspenser TBD Ver w /Own - 0 MSC 6 lea Sneeze guard Tara I. . Quote OWN/P,SC Note see elevations 1 lot Front counter Custom 19 fin. h e/- 8 2 ea Blizzard machines 300/100 12c 13A 14 15 16 1 urn Glycol system lea D Rarnd i nk to non 1 e Dipper stand ko left a Food wanners 1 ea TOPpmf Cabinet free. This line r,1 used Thts line not used 18 This line nM used 19 This line not used 20 1 lot Sine counter Metro or eq 10 I1n: h l� RSC /GC 21 1 ea Soda d sp (by purveyor) Saco FFC132123 OWWPURV. MECHANICAL HN' CIS WASTE HN. a.f.f BTU. up 24' 1 -12' vent vent ELECTRICAL VOLTS PII HP AMPS. K 120 1 RF xf.f. 0 24 up N' • 15 •/- up 36' confirm confirm up 24• Cold Zone IW IDD ' IDO DOFC -5A 132003 132003 Confirm ORTCF RSC /IDO 20 115 115 110' 120 120 208 120 120 120 1 /4hp 1 /dhp 2 hp 31.8 07 0.35 0.35 24 24 >6' confirm REMARKS Phone connects to POS Drain. R sink . or nub drain plan Drain to floor. sink or hub drain near. see plan No power C required, conftrm wrowner if control is add.: Ih 110V 2 amp Pmver conned wounl be rer Venfy al out d Sneeze guard to be mounted to counter lop 3M adhesive by General contractor See details 8 elevations Reuse ex.. eq. from warehouse Verify eq. requirements w/Owner poor to stub ups Rolled edges v. shelf below. GC to col to handsink on site. Water cooled. dram 10 floor sink bola" by GC Mix pump to be local. inside walk in refer. confirm height 8 location w /owner. Locale una on roof. Provide power to roof Wdh counter top units list. below With counter top units I.ed tebw Counter top ones (2 ea dip shrill Wan P tarn top See delay 2 /AS. similar v. cut-out ecenornern install by GC Drain to flour sink Orange Julius- Spulhcehler 9 This line not used 10 Thls line not used 11 1 ea Stainless steel work tab! Duke or eq, 24x36 RSC ylon DI1515 GC 3/8 3/e 12 2 ea Soll serve ice cream IDO 957R wale/ cool 1/2 12a 1 Ion Cimmone dispensers Duke or eq. 141301 RSCIIDO 120 lot Mix pump Smelling Conlin w/owne RSCRDO w/nandsink 8 faucet 21A 1 ea Carbon., (by purveyor wldnnk system 921 M90-0010 PURV 12' uo 24' 120 1 (-L& L -- vc'_ -rK- Y/ LU Wr - '�. /r_.L'•G� TI - �f�l � I.1 ! > ta '<• , /e ( ✓lTT -e -5iTRU E'( Fib f• i�l' NJ C)%'ei. b • S 1r% •.4-%� � ^�t4G P 1 p n — Cr 1,Ei ( +T . Gill- J.tiFf JIk2Ll - (EVJ Us I I ca r 14 I �.. l ice, 1 �.., 4 lf,4e ti r 18 Or c�rs`-6 - >=vP • IQTV DESCRIPTION'. PIER' MODEL. 22 tea. Sanowiche prep lable Silver King 23 1 ea. Food prep Nnk wldrain b Duke or eq 24 1 ea Bun steamer Neamer Ernberglo 25 1 ea Secumy monitor By ovirner 26 19.4. C!_ - S Fief 27 This line not used 28 1 ea Table lop freezer Silver Kin. 29 ea Fryer Frynaster Mier dumpstalion 2. 1 ea Heal lamp By owner 30 to SKUCF -7 FMHSOBLSC eery E' rag Exist. SKSB -48-8 RSC SUPPLIER 11W CW'WASTE RSC 1/4' xtsli. , venly existing vent, CQ RSC 1/4• MECHANICAL 1 5 Hz. xrl BTU• VOLTSIPh 120 120 120 120 115 IIP 1 /4hp 1 /4hp RSC Own 31 1 lot ] 2 1 ea 3 ] 1 ea F i Hood 68 - X42 X24 Thermal Exhaust Products. Capture jet w/ speed con col Mix Ulu system Cornelius Wall shell for 4/33824 Metro Existing St H 10, roller aria Under n era5nwasn Hoban TBS Dayton RUE, K -B Glycol system 2d - x 48• 255 LX30H Verif Dt15t5 Metro or eq Etas. ref Vent Scotsman existing vent, Scotsman eta., vent, Everpure CC71 -MC Ivan To be setae Purveyor 30 Duke or eq. Vent' ist. vent, AOS n a 70. gal. Verdy existing verity Verif y existing. verily Metro or eq 6y owner By owner TBD TBD OwNGCIRSC RSC RSC /GC Existing RSC GC GC RSC /GC 1? 318' Existing Etas, RSV. c2 36 36A 37 38A 1 ea 39 1 ea 40 1 ea 41 1 ea St SII Work lane :ert'L,.1K1' a Washers arcombo ¢a HOt water lank gas 42 43 48 1 lot 1 ea 1 ea l ea lea 2C+ H M sink 8 counter Metro base wIP lam counter lop Wire shelves Ice Machine Ice Bin Water finer. system Bad in box system Floor mounted vino sink 3 comp sink Wall mounted Shelf Sale File cabinet Walk In freezer /refer 4.5 In drain 12 P.SC /OWN 3/4 1/2 3/8 1 1/2 12 See NOM 12" 80K ELECTRICAL 120 120 120 120 120 120 120120 208 120 exMino verily exists,. verily 170 1 12020 s 266 I 12020 3 1 /4hp 013 3/dnp AMPS Isw 15 sD 15kw 123 wads 1.7kw Het. id.f. c o nfum -2S 2 -04 ;osse rEH 60- vent ,ta i rnCM 318 REMARKS WM faucet '... Mormon ca. - :confirm interconnect Finermagic I" gas conned St .1w /basket Mt GC to install Et balance HVAC See sheet M/E l for details 6 sizing. See sheet A.4 for hood shad section GC to word. fnvaa per mfr recommendations. GC to provide blocking in wall 8 install sneNes Hi. temp. with booster Venfy existing 8 install height with faucet Similar to dot. 2 /A5 con firm GC to reoasnion per owners direction. Confirm pants of connect 8 remote Glyco sys. Drain to floor sink GC mstafi. Drain to floor sink. ve shelf below VAIK Direct connect GC to provide Nock. in wag Compressor on roof. w/ I weather i to/.7 :u 2" 1/4' Cora drain to flop sink below me a e(Y ch. ¢ I 4 " • (2) a-fj ccu r' - - CG Ed LO C V J COU e� r D F L 2 w ( I Mcl�r1 ,. Pod 4U" _ �+ 22 Y N NOTE. ITEMS #12 SOFT SERVE rA ITEM -- #38 ICE MACHINE TO BE ON REMOTE GLYCO r*2 SYSTEM. CONFIRM ALL REQUIREMENTS W/ 0- ' MANUFACTURERS SPECIFICATIONS. 4 3 {� " C -00I )7I,r cuae�ti� 1 CCU 7 FILE C r:lt r •t? n T. f ,.. ^: SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ELECTRICAL ❑ PLUMBING 0 G sS PIPING CITY OF TUKWILA BUILDING DIVISION THE MEDICI CONSULTANTS 410 Bellevue Way SE, Suite 201 Bellevue, Washington 98004 Tel: (206) 453 -9298 Fax: 453-0058 Sev U • l c, '1"7- ju uus/ Drawn By: EF Checked By Owner Approval: fir/- //s .v /i./ 4 '7 Co z4 A- 1 %- ` �� /O s- t1 ;.F3 sA i JST ,�pPRO�F� JAN 2 8 1998 gD LDIPJG DNISION - 1 Pr feel No' C1- t ' � GJTL���F- l -('�t D.R: i-2 •'',T This drawing is the exclusive property of The Modiei Consult. , and on be reproduced only wish the permission of the Architect. %nations and Modification 55 work shown en this drawings shall not be carried on without written permission from the Architect g!- J(' 4-voc �. - ca.oL. q2" GLEY>: �'JM > NII I I IO G:Ja 1 c j •Ar Fly 1% � IL 21 G s - Irk - 71-1 LIrjJIG UMc °g fl1 J rc.x- 1-1,/5 ..- "re Mr., 11. li 1 4L,T a • c!4MOMG sLEElfi n - a N ' ` o G L GCe-1 cop (�• ✓? s4 rUU, ±-IT T? 1 0 _fin CrU!Lj ( — LL 15EY- b M/ I roP v, w'-- ik 12 ! Guj-.F f• -- CL2*4._Novil1 ".� , /B 2Z LEA e - rr1 co G t z ,- I r ^ "� e4 c Ii; C.G. GJEG C7 t�M��rGi Zvi LL. ^P L± L.II }h Arm D it RECEIVED CITY OF NKVillA JAN 2 1 1998 PERMIT CENTER THE MEDICI CONSULTANTS 410 Bellevue Way SE Suite 201 Bellevue. Washington 98004 (206)453 -9298 fax 453 -0058. Rer.nK�L I��I ?- Lk-4J e�C C.T. OtzN,k -- J1J LI / Dsawn By: T Checked By Owns Approval: Imc: 1.20.9$ /44 z.swuc do/ /Z f e4414A7, 44 ?kit' i 4il �aS 3 ft-i1 333 - 6sli-c '541// -g*7T,E ieG go 1:=51 1_ up; OF Tu r(lL ,}AN 28 1998 BUILDING This drawing is the exclusive property of The Medici Canadian., and can be reproduced only with the - permission of the Architect.: Variations and modificauons to work shown on this drawings shall not bo carried out • without written permission from the Architect. • Pro*, No: DeAt.�Gc 1 O_I VS S4- APPLIANCE HEAT GAIN CALCULATIONS ITEM QUANTITY HEAT KW LOAD AMPS - V PHASE USAGE FACTOR SENSIBLE BTUH. LATENT BTUH P05 3 0.1 - ' BTUH FACTOR 2984.80 120 1 100% 1024 5.33. BLENDERS 2 0:35 2754.00 00.00 120 1 '25% 597. 5. PEOPLE DROP -IN ICE BIN 3 0.1 5 120 1 13% 1120 7. OUTSIDE AIR SOFT SERVE ICE CREAM 2 5544.00 4.86 HEAT IS REJECTED `0 GLYCOL SYSTEM 3/4 HP MIXING PUMP 1 • 0.7 1908.75 120 1 100% 2389 10868.00 GLYCOL SYSTEM 1 TOTAL = (SENSIBLE • LATENT) = COOLING - LOCATED ON ROOF FOOD WARMERS TOPPING CABINET FREEZER 4 1 0.54 20 120 120 1 1 100% 13% 7372 1280 SODA DISPENSOR 1 0.35 .120 1 507.. 597 CARBONATOR 1 0.35 120 1 50% 597 SANDWICH PREP TABLE 1 6.5 120 1 25% 666 BUN STEAMER 1 1.5 120 1 25% 1280 320 TABLE TOP FREEZER 1 6 120 1 13% 384 FRYER 1 9 120 1 100% 3686 HOT DOG ROLLER GRILLE 1 1.7 120 1 100% 5802 UNDER COUNTER DISHWASHER 1 50 120 1 6% 1229 ICE MACHINE 1 10 208 3 13% 640 BAG IN 805 SYSTEM 1 0.35 120 1 13% 187 ORANGE JUICER 1 15 120 1 13% 768 WASHER /DRYER COMBO 1 30 208 1 10% 2130 533 WALK -IN FREEZER /REFRIG. 1 LOCATED ON ROOF TOTALS 31748 853 HVAC SCHEDULES ROOFTOP UNIT (RTU) SPECIFICATIONS MANUFACTURER: CARRIER (EXISTING) COOLING CAPACITY (AT ARI CONDITIONS) MODEL: 50CD0065800A AIR ENTERING CONDENSER: 95 F DB VOLTS /PHASE /HERTZ 208/1/60 AIR ENTERING EVAPORATOR: 78F DB/ 67 F WB EER RATING: 7.8 TOTAL COOLING CAPACITY: 61000 BTUH TOTAL WT. 610 LBS SENSIBLE COOLING CAPACITY: 48200 BTUH COMPRESSOR INPUT: 5.28 KW EVAPORATOR FAN PERFORMANCE CFM: 2000 HEATING CAPACITY: 4.5 KWH. EXTERNAL SP: .6" WC GAS: NO MOTOR HP: 0.75 HP N/A INPUT OUTSIDE AIR (MIN): 112 CFM N/A OUTPUT ACCESSORIES PROVIDE NEW MICP.OMETAL OUTSIDE AIR HOOD SECTION. ECONOMIZER: YES HVAC RELIEF: N/A SEE CONTROLS SEQUENCE OF OPERATION DOWNTURN PLENUM ANTI -SHORT CYCLE TIMER AUTO- CHANGEOVER T'STAT WITH FULL PERIMETER CURB CRANKCASE HEATER HEAT -COOL- AUTO -OFF AND THROWAWAY FILTERS 5 -YR COMP. WARRANTY FAN - AUTO -ON- SWITCHES IN SUB -BASE • HEATING PROVIDED BY DUCT HEATER, HTR -1 KITCHEN EXHAUST FAN MANUFACTURER COOK 1/4 MOTOR HP, 907 CFM, 120V/60HZ/1PH POWER MODEL 120V2B FAN RPM: N /A, O.7 ESP, BELT DRIVE MOUNTING CURB SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER EXIST 840 CFM, 120V/I PH /60 HZ, 1 HP MODEL EXIST 0.25" WC SP, BELT DRIVE MINIMUM CFM CALCULATIONS LEASABLE AREA 560 SQ.FT. 1.5 CFM /SO.FT. = 840 CFM NOTE: MINIMUM STATIC PRESSURE SHALL BE .25" W.C. HVAC CALCULATION FORM - FOOD COURT MAKE & MODEL SUMMER SPACE 76 DEG. F O 50% RH OUTSIDE. 84 DEG. F DB / 68 DEG. - F WB HEATING SPACE 72 DEG F OUTSIDE, 21 DEG. F ROOF If = 0.09 CLTD = 68 HEAT LOSS SENSIBLE HEAT GAIN LATENT HEAT GAIN ITEM QUANTITY FACTOR 4.59 BTUH 2570.40 - FACTOR BTUH FACTOR 2984.80 2 BTUH 1. ROOF AREA 560 SOFT. 5.33. 2. CORRIDOR WALL 3. OUTSIDE WALL 4. LIGHTING •• 360 SQ.FT. 0 SOFT. 2.61 KW 7.65 17.34 2754.00 00.00 Q.75 • 3413.00 270.00 0.00 8909.00 325.00 1625.00 853.00 5. PEOPLE 5 PEOPLE ALUMINUM W/ TITUS AG -75 OPPOSED BLADE DAMPER JAM 2 1 1998 315.00 1575.00 31748.00 6. APPLIANCES SEE APPLIANCE CALC FORM 1900 7. OUTSIDE AIR .2 CFM /SF = 112 CFM 49.5 5544.00 4.86 544.00 TITUS /50F -NT 754.00 3232.00 8. FAN MOTORS 3/4 HP 12 - X12' TYPE 3 2545.00 1908.75 TOTALS 10868.00 - 47938.00 TOTAL = (SENSIBLE • LATENT) = COOLING BTUH 57403.85 BTUH •• LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON "ELECTRICAL DATA FORMS" •WALL FACTOR OUTSIDE WALLS NORTH . 4.08 EAST - 8.84 SOUTH - 6.46 WEST = 6.46 REMARKS: REGISTER, GRILLES AND DIFFUSER SCHEDULE SYMBOL MAKE & MODEL SERVES OTT MAX CFM NECK SIZE BORDER TYPE MATERIAL REMARKS CD -1 TITUS/TDCA -AA BACKROOM AREA 2 500 12"X12 TYPE 3 LAY -IN ALUMINUM RECEIVED CITY OF TUKWILA CD -2 TITUS/TDCA -AA SALES AREA 2 500 17X12" TYPE 1 SURFACE ALUMINUM W/ TITUS AG -75 OPPOSED BLADE DAMPER JAM 2 1 1998 RG -1 TITUS /50F -NT BACKROOM AREA 1 1900 24 "X24" TYPE 3 LAY -IN ALUMINUM ''ERMITCENTER RG -2 TITUS /50F -NT BACKROOM AREA 1 100 12 - X12' TYPE 3 ' LAY -IN ALUMINUM EXHAUST /SUPPLY FAN SCHEDULE SYMBOL MAKE & MODEL SERVES - CFM ESP RPM MOTOR VOLTS /PH TYPE WEIGHT REMARKS EF -1 COOK /120V2B EXHAUST HOOD 907 0.70 in. w.c. - 1/4 HP 120V 10 ROOF /UPBLAST 66 LBS INTERLOCK WITH HOOD SWITCH PANEL EF -2 EXISTING SMOKE EXHAUST 840 0.25 in. w.c. - 1/4 HP 120V 10 ROOF - FAN IS EXISTING/ SPACE VOLUME UNCHANGED SF -3 KANALFLAKT /K8 EXHAUST HOOD 79 0.75 in. w.c. 2404 1/8 HP 120V 10 IN -LINE - HOOD INDUCER SUPPLY FAN ELECTRIC DUCT HEATER SCHEDULE SYMBOL MAKE .& MODEL SERVES CFM ESP KW AMPS VOLTS /PH TYPE /SIZE CONTROL REMARKS HTR -1 ENVIROTEC /- HVAC 2000 0.10 in. w.c. 4.5 21.3 AMPS 208V 10 OPEN COIL /18"X18" We INTERLOCK WITH T -STAT AND HOOD FAN RELAY DIVISION 15 - MECHANICAL SPECIFICATIONS (GENERAL) CODES AND ORDINANCES CODE ALL WORK SHALL COMPLY WITH APPLICABLE BUILDING, VENTILATION AND ENERGY CODES. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMANCA, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. AIR MOVING - TREATING EQUIPMENT & MATERIALS AIR HANDLING UNITS EXISTING DUCTWORK: ALL RIGID DUCTWORK SHALL BE LOW PRESSURE SHEETMETAL CONSTRUCTED IN ACCORDANCE WITH SMANCA STANDARDS. EXHAUST FANS SEE PLANS FOR SIZE CONTROLS - SEQUENCE OF OPERATION THE THERMOSTAT IS EXISTING. THE CONTRACTOR WILL PROVIDE ALL NECESSARY RELAYS, SENSORS, & WIRING TO EFFECT THE FOLLOWING SEQUENCE OF OPERATION. 1. THE ROOFTOP PACKAGE WILL START /STOP OFF THE EXISTING PROGRAMABLE THERMOSTAT. 2. THE OUTSIDE AIR DAMPER SHALL OPEN TO 300 CFM POSITION WHEN THE HOOD EXHAUSTER IS STARTED. OTHERWISE, OUTSIDE AIR SHALL BE SET TO 115 CFM. 3. THE DUCT HEATER SHALL BE ENERGIZED BY THE EXISTING THERMOSTAT. FIRE DAMPERS INSTALL UL LABELED FIRE DAMPERS IN ACCORDANCE WITH NFPA AND LOCAL CODES ACCESS DOORS INSTALL ACCESS DOORS IN DUCTWORK AT ALL EQUIPMENT REQUIRING ACCESS. COORDINATE ACCESS DOOR LOCATIONS WITH ARCHITECT. REGISTERS, GRILLES, AND DIFFUSERS SEE SCHEDULE. WHERE INSTALLED IN EXISTING HARD CEILINGS, INSTALL NECESSARY FRAMING. PATCH CEILING AS REQUIRED TO PAINT FINISH. GRID SUPPLY PLENUM FOR ALL SUPPLY AIR DIFFUSERS WITHOUT THREE (3) DIAMETERS OF STRAIGHT RUN INTO THE DIFFUSER, A GRD SUPPLY PLENUM CONSTRUCTED PER THE DETAIL SHALL BE PROVIDED. THE PLENUMS ARE DESIGNED WITH A SIDE INLET AND PERFORATED LOWER HALF DIVIDER TO DISTRIBUTE AIR EVENLY ACROSS THE DIFFUSER. OPPOSED BLADE DAMPERS TO FACILITATE BALANCING OF DIFFUSERS IN AREAS WITH HARD CEILINGS AND NO ACCESS TO THE VOLUME DAMPERS AT THE BRANCH TAKE- OFF, AN OPPOSED BLADE DAMPER (TITUS #AG75 OBD) SHOULD BE INSTALLED AT THE NECK OF THE PLENUM HEAD. THE DAMPER ADJUSTMENT SCREW WOULD BE ACCESSED THROUGH THE DIFFUSER CORE. THERMAL COVERING NFPA FLAME SPREAD OF 25, SMOKE DEVELOPED 50, NO EXCEPTIONS. DO NOT INSULATE EXPOSED DUCTWORK. INSULATE PER THE REQUIREMENTS OF LOCAL ENERGY CODE. FLASHING AND COUNTERFLASHING FLASH AND COUNTERFLASH ALL PIPING AND DUCTWORK PENETRATING EXTERIOR WALLS AND ROOF IN ACCORDANCE WITH LANDLORD'S DETAILS & WITH APPROVED ARCHITECTURAL STANDARDS. TESTING, ADJUSTING AND START -UP THE MECHANICAL SUB - CONTRACTOR IS RESPONSIBLE TO PROVIDE COMPLETE SERVICES FOR TESTING, ADJUSTING AND STARTUP OF ALL EQUIPMENT AND MATERIALS INSTALLED UNDER THIS DIVISION INCLUDING TOOLS. INSTRUMENTS, LABOR AND SUPERVISION. ADDITIONAL LANDLORD SPECIFICATIONS IT IS THE INTENT OF THE ABOVE SPECIFICATION TO IDENTIFY SPECIFIC REQUIREMENTS OF THIS PROJECT. ENCLOSED WITHIN THIS CONTRACT DOCUMENTATION IS THE LANDLORD'S SPECIFICATIONS. IF CONFLICTS EXIST BETWEEN TWO SPECIFICATIONS IT IS THE CONTRACTOR'S RESPONSIBILITY TO BRING THESE CONFLICTS TO THE ATTENTION OF THE ARCHITECT. THE CONTRACTOR IS RESPONSIBLE FOR THE MORE STRINGENT OF THE SPECIFICATION REQUIREMENTS. >y1GSOOjO NOTE: ALL COMPRESSORS ARE ASSUMED TO GIVE OFF HEAT AT 125% OF RATED INPUT MECHANICAL LEGEND GENERAL EQUIPMENT: DUCTWORK: 12 X 8 TERMINALS: t EXISTING WORK OR BACKGROUND (UGHT LINE) NEW WORK (HEAVY LINE) TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) ROOM THERMOSTAT (T), SENSOR (5) DUCT (1ST FIGURE = SIDE SHOWN, 2ND FIGURE = SIDE NOT SHOWN) FLEXIBLE CONNECTION VOLUME DAMPER 45' TAKE -OFF 90 RECTANGULAR TAKE -OFF WITH 45' TAPER FLEXIBLE DUCT ROUND DUCT INDICATOR CD -1 DIFFUSER /GRILLE TYPE & NUMBER 400 DESIGN CFM (WHERE APPLICABLE) CEILING DIFFUSER (FLOW ARROWS SHOWN ONLY IF AIR FLOW NOT SYMMETRICAL) �r CEIUNG RETURN /EXHAUST GRILLE RVILp(tSG 0,5701N THE MEDICI CONSULTANTS 6 ■ ■ • 410 Bellevue Way SE, Suite 201 Belle a WA 98004 Tel: 207) 459 -9298 Fez: 20 6) 459 -0058 immassmossimmastis HV Engineering, Inc. C W.� Eng,ne<rs ® 15100 SE 38th Street, �1Bt. Sui,c 851 Bellevue n6nA gWn , nAAI o (206) 706 - 9669, FAX (206) '106 -1030 CD I EXPIRES: 8/1/97 Reyialone LE. Hf, ITT ! �%D I'AA E4A:.A% Cabe ua5 ORANGE JULIUS, DAIRY QUEEN SOUTHCENTER MALL TUKWILLA, WA MECHANICAL LEGEND SCHEDULES & SPECIFICATIONS Drawn By: �7D Checked Ry TA Owner Approval: Project No.: 97004 Date: 3 -11 -96 111 GENERAL NOTES: 1. REMOVE EXISTING DIFFUSERS & DUCTWORK AS NECESSARY TO INSTALL NEW WORK SHOWN. KEY NOTES: <> INSTALL DUCTWORK IN SLOPING 1HR SHAFT UP TO EXHAUST FAN ABOVE. LOCATE FAN ON ROOF 10' AWAY FROM OA OPENINGS/ INTAKES INTO BUILDING. INSTALL PER LANDLORDS DETAIL 2 ON SHEET TTM -4 O SEE ARCHITECTURAL PLAN, SHEET M /E -1 FOR DETAILS OF HOOD INSTALLATION REQUIREMENTS. O OUTLINE OF EXISTING HVAC UNIT ON ROOF. PROVIDE NEW OUTSIDE AIR HOOD & DAMPER SECTION AS INDICATED ON SHEET M -1. NOTE THAT THERE IS LIMITED SPACE FOR HOOD, IT IS RECOMMENDED THAT CONTRACTOR FIELD VERIFY DIMENSION FOR CUSTOM REQUIREMENTS. FIRE PROTECTION NOTES: 1. FIRE SPRINKLER PROTECTION IS EXISTING, THE CONTRACTOR IS TO RELOCATE HEADS AS NECESSARY. 2. SEE SHEET TTM -2 & TTM -3 FOR LANDLORD REQUIREMENTS & SPECIFICATIONS. 12 "0 8"X9" EA UP - 0 EF -Ii RG -1 1000 M9e -ooio UCT ON ROOF 12 "0 CD -2 500: HVAC PLAN SCALE: 3/8 "= 1' -0" EF -21 (SMOK 1:x187 ISF -3l 8 "0 CD -1 500 RG -2 100 CD- 2 500 12 "0 EXISTING) EXHAUST) CD -1 500 RG -1 1000 HTR -1 EXISTING SUPPLY & RETURN DUCTS UP TO EXISTING HVAC UNIT ON ROOF OUTLINE OF NEW OUTSIDE AIR HOOD ON ROOF HVAC UNIT RA DUCT OPEN TO RA PLENUM BELOW. SMOKE DETECTOR, SEE LANDLORDS SPECIFICATIONS FOR FURTHER REQUIREMENTS. NEW HOOD ® - 7' -0" FLEX DUCT NOTES: SEE PLAN FOR DUCT & DIFFUSER NECK SIZES HARD LID CEILING USE "HARD" DUCTWORK DOWN TO DIFFUSER. MAXIMUM HORIZ. LENGTH OF FLEX SHAFT NOT TO EXCEED 24" (TYP.) 1. PROVIDE SUPPORT FOR CEILING DIFFUSER AND CAP AS REQURIED BY UBC 4718. 2. EQUALIZING GRID REQUIRED ON SUPPLY AIR DIFFUSERS ONLY. NOTE: PROVIDE SUPPORT FOR DUCT & CEILING DIFFUSER PER UBC REQMT. CEILING DIFFUSER DETAIL © HARD CEILING AREAS SCALE: NONE OVAL CONNECTION MAY BE USED FOR AREAS WHERE CLG SPACE IS LIMITED PLAN MOUNTING FLANGE DIA EQUALS FLEX DIA ELEVATION SHOP FABRICATED CEILING DIFFUSER CAP; NET INSIDE DIMENSIONS SAME SIZE AS DIFFUSER NECK DIFFUSER NECK (SQUARE OR ROUND) EQULIZING GRID, SEE • NOTE 3 SECURE DIFFUSER CAP TO DIFFUSER NECK WITH SHEETMETAL SCREWS. MINIMUM ONE PER SIDE. SEAL JOINT AIR TIGHT. CEILING DIFFUSER APPRO JAN 2.8 1998 gtii 3. EQUALIZING GRID, FULL SIZE OF DIFFUSER CAP. PERFORATED 22 GAUGE SHEET METAL 3/16" HOLES ON 1/4" STAGGERED CENTERS. LOCATE PERPENDICULAR TO STUB DUCT, HEIGHT TO EXTEND FROM DIFFUSER NECK TO FLEX CENTERLINE. SECURE TO EACH SIDE OF DIFFUSER. CEILING DIFFUSER CAP DETAIL SCALE: NONE TITUS AG -75 OPPOSED BLADE DAMPER CEILING DIFFUSER //( RECEID cm of r JAN 2 1 1998 "ERMIT CENTER THE MEDICI CONSULTANTS ■ ■ ■ 410 Bellevue Ray SE, Suite 201 Fax: ti2 Ball WA 98004 Tel: ) 459 -9298 0t8) 459 -0058 HV Engineering, Inc. C Itine Engineers © tetoo sE sacs strset, idol, sane eat He:lewe. Feshingtoa, 88008 Q (208) 708 -0889. FAY (208) 708 -1830 t. Z ONAL I EYFIRES: t1/1 /97 Revisions /\ sid17 LA , DiPeD ORANGE JULIUS, DAIRY QUEEN SOUTHCENTER MALL TUKWILLA, WA MECHANICAL HVAC PLAN, DETAILS & FIRE PROTECTION NOTES Drawn etv: •sV Checked Bp: - T=' Owner Approval: Project No.: 97004 Date- 3 -11 -97 M2