Permit M98-0026 - BOEING #7-600
N 0 O --a _t City of Tukwila (206) 431-36 70 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M98 -0026 Type: B -MECH Category: NRES Address: 600 ANDOVER PK W Location: Parcel #: 262304 -9123 Contractor License No: HERMAC *217NT TENANT BOEING #7 -600 600 ANDOVER PK W, TUKWILA WA 98188 OWNER HOME ELECTRIC COMPANY PO BOX 9, BELLEVUE WA 98009 CONTRACTOR HERMANSON CORP. 1221 2ND AVENUE NORTH, KENT, WA 98032 CONTACT LARRY RUFF ]221 2 AV N, KENT WA 98031 ********************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: RELOCATE GRILLS & REWIRE AND.ASSOC DUCT WORK WITH: SMOKE DETECTION. Valuation: 2,850.00 Total Permit Fee: 42.81 * * ** f * * * * * * * * * * ** * ********************** ** * * * * * * * ** * * * ** ** * ** * * * * * * ** ** UMC Edition: 1994 Per it Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work.. I am authorized to sign for and obtain this uilding pe mit. Signature: _ Date: IIS' _ C) & Ss Title: Print Name: Status: ISSUED Issued: 02/17/1998 Expires: 08/16/1998 Phone: (206)455 -1341 Phone: 206 575 -9700 Phone: 206 -575 -9700 ccap_Off7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the: work is suspended or abandoned for a period of 180 days from the last inspection., Project Name/Tenant: F3U6 / Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and storage location on se•arate 8 1/2 X 11 •a•er indicatin • •uantities & Material Safet Data Sheets Value of C st e u Site Address: �� f G(,D V -- NO City State /Zip. Tax Parcel Number: z.& 2 04 r (1 Z3 Phone: Property Owner: City /State /Zip: Street Address: DD Dot 3"ID7 0 Water .) C State /Zip: (ma '-Eit/C— Fax #: Phone: Contact Person: Street Address: lZZ( 2 &) City fate /Zip: Kit WA 31 Fax #: 2a,0- 5 /5- '' fib Contractor: i I f 144 .A 1tWY1 ! . Phone: "Lv (o - 5'15 9 '1 0 0 Street Addre s: .1 7 �. 1 AO �-� �_ it State /Zip: 1,�1c�� ! Fax #: , z0(.0 S'7 S� `��Da Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax ft: MISCELLANEOUS PERMIT REVIEW' AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) '� Description of work to be done: Q- ti gtii .g fr'ewt ,.e, 1 al-Soc., �* u. c* w L W' � \ .1 .' • )414 1, o Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and storage location on se•arate 8 1/2 X 11 •a•er indicatin • •uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks • Commercial Reroof ❑ Demolition ❑ Fence I & Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO::' Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous CITY OF TUKWI LA Permit Centel 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 F! R STAFF USE ONLY Project Nuriioer: Permit Number: die- 00Z. Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT41EQUEST ;EOR:MISCELLANEOUS PUBLIC. WORKS. PERMITS i ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: O Moving Oversized Load /Hauling WATER METER DEPOSIT /REFUND' BILLING: Name: Address: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application 2 accepted: Date application expires: Appllc tlon taken by: (Initials) 1 -9� - MISCPMT.DOC 7/11/96 Phone: City /State /Zip: BUILDING W ER OR AUT OR/ZED'AGEN SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW ❑ Signature: Submit checklist No:... M - " Antennas /Satellite Dishes Submit checklist No: 1 �- t Date: 0, ) "•} _C ' , ll Print name 1 , !rA A c� i G `�` t C-14 I<c one• ,0 <n 5 S-- T x #: _� �A —S7S b i addres' d �.� 1 to r� ra A Lt /I � Submit checklist No':M3iM -3w: it State! ip: o n c, LCD G. q l 3 2 ALL MISCELLANEOUS P ' LICATIONS MUST BE SUB ED WITH THE FOLLOWING: ➢ AL!_ DRAVII,IF GS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, contractor;liaohsed,: by the State of Washington, a notarized letter from the property owner authorizing the agent to submit thIs permit applioatlon obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 1 p,. MISCPMT.DOC 7/11/96 k7 4 r ti. , ••9 t -•• SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW ❑ Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width, which exceeds 2:1 Submit checklist No:... M - ❑ Antennas /Satellite Dishes Submit checklist No: 1 ❑ Awnings /Canopies - No signage Commercial Tenant. Improvement Permit ❑ Bulkhead /Dock Submit checklist' No: M-10 . ❑ 'Commercial Reroof Submit checklist No : ' M ❑ Demolition Submit checklist No':M3iM -3w: ❑ Fences - Over 6 feet in Height Submit checklist' No: .M9' :. ❑ Land Altering /GradinglPreloads Submit checklist ' ' No: M -2 ❑ Loading Docks Commercial Tenant nprovement. Permit.,: Submit checklist No: H-17 ❑ Mechanical (Residential & Commercial) Submit checklist No.: M-8; Residential `only - H -6; H-16' ❑ Miscellaneous Public Works Permits Submit checklist No; H ❑ Manufactured Housing INSIGNIA ONLY) Submit checklist No M 5 ❑ Moving Oversized Load /Hauling Submit checklist No: M 5' = :' >;` ® Parking Lots Submit checklist No: M -4 ❑ Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No:: M -6,. ❑ Retaining Walls - Over 4 feet in height Submit checklist . No:. fall ❑ Temporary Facilities Submit checklist No: 'M -7- ❑ Temporary • Pedestrian Protection/Exit Systems Submit checklist No; M '. ❑ Tree Cutting Submit, checklist :•. No: M - ALL MISCELLANEOUS P ' LICATIONS MUST BE SUB ED WITH THE FOLLOWING: ➢ AL!_ DRAVII,IF GS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, contractor;liaohsed,: by the State of Washington, a notarized letter from the property owner authorizing the agent to submit thIs permit applioatlon obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 1 p,. MISCPMT.DOC 7/11/96 k7 4 r ti. , ••9 t -•• Address: 600 ANDOVER Pi( W. Per Mit No: M98.70026 t.lite: • . . • • Tenant: BOEING #7-600. H Status: ISSUED, ,• . • ..,, Type: B.44ECH : • Applied:, 02/1,10998 • Parcel. #: 262304-9123 • Issued: 02/17/4998'. • . ****AkA*******.k*****A*Ot****4**4(**************************A4(** Permit Conditions: • . , . • 1. No changes will be made to the plans .unless approved by the Architect or 'Engineer aa0,-.01P-Jidtwila 'Building Division. ,...:, 2'. • A l l p e r m i t s , i n s pe.gtgr5e41"&:44:h7dp, ro v e d plans : shall i he • 'available at Me::;!"ore prior 's et • of any con • , • St ru c t i on . ,„.. dos um ep s •. a r4 to be iiia4.11'1#ki;red and aval 1 a b 1 e un t 1, a 1 .,,, ilu ..ipp. i'i iln e0.0 v a 1 Aq q t;i g r''zill 3. All c a ri,s,s5tift t i or t,614p6X, do rVe fn 69311°0 '1)0 w tqlvep p rove d p 1 an of yn i f o r s reely ft'tententE, o thR ts •, ill' 0 4n g '114 dii (1994 . . Ed" ti!"Ort)' a S a de iVti ed , Uri - to ri» Me etferk ca ,t4, 994 Ed i t i on ) :an t tbrV' State • Ehe'ctg:y,,, e (19'9•1 i ii ii tp,p , -,., „ i, , i .,\ • 4 . V a/ t y tYt i . Th'e:k i9pe of a • IN 'ir,,,:bno. Oroy a 1 .of tor , or a t , -,,, 0. 0:fah's - spec i f i-,8at i onsl' t(th coriiiiip t a t i ons 10 l' 111 . r t$ en - . • . ' Skit' e , d ,to be pe„rfiltt /an approval ot, arw- . ti ip. ,,,:a ' . . • :,.. ,•,. c., f s . ,..,' s . • ' ,ii s ,A . /OP arly,:ol. the prowl 51 onsi"1-?'f he building code , ot40:f . any .• da h e '''l'Or Ci in'ance 61 . .the p6rfidi3ai on . No permtt grteutiiili4 . to 1 0. , q1 ve -,. authority t v to-1 e or oaii cel . the pro v i's1 ohs‘o,fi t,10,.. ;•, ,,,,, , .,,,\ ',, ,,...,. , . A • • I if ..... 4 1,../ q 'ilialJ Oe yaqiiltr,,, ,, fi ) • 1 :vr (,:. 1.---, . . ,.v MANUFACTU,RERS':=1.K,TALLA:IiIONI,R1 91 RE0UIREL Oir.iiATEly )ili 1!) FOR•. TilE BOXLDING 5,PEOTORS t ItY1 ,,,,, , .4)4,":„.........3 t 't .., IN 4.- • • ,;tk • ,, ,i folt • ' L r „ 1 -, / - 1 ,:,„\ , ,1 \ V.," • . f , A.:::.■ A ' . ) ' V . • c , ',",t . . tzi.P.Va.ljo , .i..1( W , ,. '''' (If =,,.), ■ , .. t . / • / i . ,C,. \- ''^-, t ,,, ,, 41` j4 • ^ON V,..... / . / h . \, .,, ,,,x • Vt.t, . %, "'V't,3.0' ,- %Pr,, , ; 44 ' . % „...f . .1,-- • • ' "0 ' \ ' 1 . e ''''' ''' . ''tY --- ..r; '0 • . '' • !! , A • k- * 4 . „ ,.• ' c.. 1 it ,,, , / / -, • ',.„ ,-.,,,.--.,,,: 34m' ,. N/ \ 1 `,., • ' \ , f A . '" ' 40 • - - ‘;'13, 1 q , • 4 ;',,, , 4':. I' ' ' l '' ' ' • ' '') ' ' • Ice, ' • • s..,•% .. •t, 'N , \ , , 4 4,,,, ,, , I'v `.". . '''n.;.,,,,t . N • , , ( CITY OF TUKWILA C ? e* vtu . PLAN REVIEW / ROUTING SL ACTIVITY NUMBER M98 -0026 DATE 2 -11 -98 PROJECT NAME BOEING BLDG 17 -600 P TMENT: �w 1 G DIVISI 1 FIRE ENTION PLANNING SION 0 UBLIC W RKS 1 STRUM PERMIT COORDINATOR it REVIEWERS INITIAL DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE p NOT COMPLETE p COMMENTS TUES /THURS ROUTING: PLEASE ROUTE ri NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF p (If routed by staff, make copy to master file & enter Sierra.) DATE APPROVALS OR CORRECTIONS: (ten days) APPROVED p APPROVED W/ CONDITIONS ❑. REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS INITIAL C:ROUTE -F DATE DATE DUE DATE 2 -12 -98 NOT APPLICABLE 0 DUE DATE 2 -26 -98 NOT APPROVED (attach comments) 0 DUE DATE APPROVED L I APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 (Cetdticadoa of occupancy requiisd. ) :REGISTRATION NUIJIBER • ' ' • 'E: ;:. .. •, .!r .!! . x2 %x.:4T • . t . : ••r T • V F • . :•.: f A T f"-. :O.7 2 Tf 8 • • ! 1' /! 1 ('J. ? 4 j r • ; ' • REGISTERED AS PROVIDED BY':LAW:AS;:A', KENT .W A 98032 SIGNATURE Pi ISSUED By DEPARTMENT OF LABOR AND INDUSTRIES This Payment 42.81 Total Fees: Total ALL Pmts: Bail ante: • AA****/.• A ,A * *A * * * * * *•k* ****0L *,1'A4's% •,tk*s�R 'k A,1,1k*4kA*,l•kA•R.10 ITY OF' TUKWII.A, WA TRANSMIT A d*' A* 4*• AA******** A. A****, 1k, 1'**• t' A* k*** k, AA *A * *,1 *,A * * *A *A * * * * *sl dk•.1*A* TRANSMIT Nurbert 89700715 Amount: 42.81 02/17/98 11:00 Payment Method: CHECK Notation: HERMANS0N CORP Irc i t: BLH Permit Na; M98- •0026 Type: L)-MECH MECHANICAL PERMIT Parcel Not 262304-9123 Site Address: £00 ANDOVER PK W 42.81 4 2 .. 0 1 00 Al *,A *4* * *A ** *.* n*** r k****' A* sl. 4 k *• *,1 *,1 ** * *A *,4't* * * *s1.t. *•'A k* * * * * * *. Account Cade Description 000 /345.830 PL(IN CHECK NUNRES 000/322.100 IMI:CHANICAL. •- UONRES. Amount 3.4.23 Project: n `6 Type of spX: io '-.--)741)-- Date called: Address: ( Special instructions: / t .y y -� , � J Date wanted: / Requester ' 5 - f 'Z7 = '- �L. C2 / o.: Phone No.: , IN- PECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspector: I Receipt No.: INSPECTION RECORD"- Retain a copy with permL'- Date: Date: �s.:"! ^ M: CrG: In ,JFS4 ^.'cir ^`r +. ^�r"rY ?i,:.il�r T�� nth£,. r l "i., '•'1 ".•..nY:1a`.�:4:� r'£'1;;: 7 -20 PERMIT NO. (2156 43i -37 - Gorrecttons-requtred prior to approval. 4,1 $42. EINSPECTI • FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Project: g a 6a) Type of inspe tion Date called: / '' Adore : Special instructions: Date wanted: ��.. a � Requester: Phone No.: 11 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Egj Corrections required prior to approval. COMMENTS: INSPECTION RECORD Retain a copy with pertriL PERMIT NO. 206) 431 -3670 27 /( , 4, , e 1 - Inspector: $42.00 R be paid at Receipt No.: Date: NSPECTIONF EE REQUIRED., Prior to inspection, fee must 00 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: Type of inspectionr vi Date called: Z / } � q / '5 r/ (4 l r 0 Ag 74aLk...- c // • 14vr 1, e-oo nGG f4 / v-' ' / i- - Special nstructions: ,l , � �--- fri r Os Y1 al-- /0 e4 r l'ea ke (-40 n-, b V--r.44 G 1 Ca L.P ce / . 7-7) /*V/i- r7U 4 v c,..e es' i . ./ h- - ...c Cs[i h e ... _ 1- J.-7 Gt /. lace) 64/1 Ylo f l-- G fr.-es-pi 4.9t I '4- li 74 A 4.-../// c? a,'.1 X4 /7 (, .. 2, 'i ` /, .., Project: Type of inspectionr vi Date called: Z / } � q / '5 r/ (4 l r Addres . , n _ _ t1sJ r'�V � V w- 0 , Special nstructions: Date wanted: 2 jo a.m. Requester: ky_r_4_,L 5 Phone No.: 5 7 q,, 6 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Inspector: I Approved per applicable codes. INSPECTION RECORD Retain a copy with per PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: 2 , 73 $42.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Proj e o e t j ( 4 1 V 6Q7 T sp @cjion C v Q `-I / i Ad O >J fvtazwo - Date called• ,,, m Special instructions: Date wante _ 1� Requester: all Phon,plp- �, ,./ 9 COMMENTS: f -trka>tl - t >J fvtazwo - (k._ -- i- / 0..5' U L•Pr • ~4 Y1 R -•R {a.. ti Inspector: `O`! N Date:2 ( 3, 5 ft INSPECTION RECORD Retain a copy with pern INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 7 1 Approved per applicable codes. Receipt No.: mc6 -ooa(o PERMIT NO, (206) 431 -3670 Corrections required prior to approval, $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: READY FOR ISSUANCE $ 4t 6 • 1 BALANCE DUE YES STATE CONTRACTORS LICENSE IS THIS CONTRACTOR IN THE SYSTEM? UIRED? NO APPLICANT CONTACTED DATE CAIA,ED CALLED BY Of • REVIEWERS INITIAL PLAN REVIEW / ROUTING.... SLIP ACTIVITY NUMBER PROJECT NAME BOEING BLDG 17 -600 DEPARTMENT: BUILDING DIVISION • PUBLIC WORKS L MQ8 -0026 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE E NOT COMPLETE COMMEENTS DATE 2 -11 -98 FIRE PREVENTION C PLANNING DIVISION' 0 STRUCTURAL fl PERMIT COORDINATOR l DUE DATE 2 -12 -98 NOT APPLICABLE El TUES /TTTURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED Er ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) DATE Z APPROVALS OR CORRECTIONS: (ten days) APPROVED n REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED ri REVIEWERS INITIAL C:ROUTE -F APPROVED W/ CONDITIONS DATE DATE DUE DATE 2 -26 -98 NOT APPROVED (attach comments) DUE DATE APPROVED W/ CONDITIONS L NOT APPROVED (attach comments) Q (Certification of occupancy required. ) 24: 4 OCCRATE R TURN 10 :10 ...WOO... 10 :10 � --Liii 1 0 215 ",' I 11 l/llll ._ 1 .. r ' r- ::;Py , aiou -103 CONTROL A R CE PRE SECON FISIMARIAFE PER v REQUIRED FO `1 ❑0 D LECTRICAL ❑ PLUMBING ❑ GAS PIPING C . TY OF TUKWI E3 J LC3ING DIVISIO %HAUST GRILLE WITH NSECT SCREEN IN SOFFIT UO OEL 365H EANAIIST FAN 55 CFY 1 1'S.P.,1050 20V, 3.3 A. INTERL , WITH AMU. TITUS T16A FF DIFFUSER , 6' WITH 6' NECK, VOL. DAMPER TYPE 3 MANE L 125 FINISH (TYPICAL UNLESS NOTED OTIERWISE) I � IN 1 Under Nand the tout to err r:..:3 does r.c'‘ c ac:apted cc:.'D or copy c: T• FIRE TIT CONTROL A COMPRES • • 2 2 244 r, '210_ I. 6 FLEX s n�n�' R El 24124 EGO:RATE RETURN 10116 EZI •-14' 200 101 II MAW — •— .4•111111 w ��- =.I I wo 11 $ "'WNW 4 4 . 4 6 ' IMO 4111•11 5 .5KW .. 12116 ■ g zoo e' 1'110 12116 14'' R 10 XHAUST GRILLE WITH NSECT SCREEN IN SOFFIT MO OAN OCL 365H EXHAUST FAN 5s crM Y 1'5.P.,1050 RPM. 20V, 3.3 A. INTERLOCK WITH AHU. ; �r •••- • 10110 1011 ''J ...1 C:'.. :::d cmicuion3 r.ni . of orize the violation of cny o dlistoi , Receipt of contractor's P11111111101111MMiedeed. -, I � N 1 INSTALL 14'01A. SPIN -IN WITH MAMJ+. 1 41.1.11E DAMPER Al A MINIMA( DISTANCE OF 4 FT rRCH DUG' HEATER PER NE: REQUIREMENTS. RELOCATED 6'DIA. NECK CEILING DIFFUSER. REPLACE FLEX DUCT WITH A LONGER FLEX IF REOJIREO. ND RELOCATED CEILING GRILLE. FABRICATE A INSTALL ` 16' DEEP PLENUM CAN 10 A.OMODATE 1 DIA. au AIR TRANSFER DUCTS. POINT Cr CONNECTION Cr NEW GALVmI2EC SHEET META. DUCT TO EXISTING DUCTBOARO. UTILIZE SPIN -IN with VOLTA( DUPER. POINT or CONNECTION Or NEW 6' DIA. FLEX DUCT 10 EXISTING DIFFUSER. © RELOCATED THERMOSTAT TN WALL Al 5'-C' ABOVE FLOOR LEVEL. ® CAP 6' 01A DUCT © POINT OF CONNECTION Or NEW 10' LATERAL TEE TO EXISTING 20' GALVANIZED SHEET METAL HIGH VELOCITY DUCT, ROUTE 10' DUCT 10 CROSS OVER EXISTING DUCT. 1RAN51190 9 DON TO 6' THEN CONNECT 10 VAV Box USING A 3 FT LONG MAX FLEX DUCT. DO NOT BE oR KINK FLEX DUCT. Q►' ACCEPTABIUTI' TI E M ON MOAN mcw N• a soma . O� /••, r Mn. OAR 4 o 811 DS LwMa AMMO NO 8 V r 700 10110 7 - -n ~ -- '- u • /4 OM NMI E, v Fit / tip • � lr 0 UCLYMMCA. MASTER HVAC PLAN BUILDING 7 -600 COL A -H 1 -5 TtMMLA GENERAL NOTES: C::> TITUS MCD MODULAR DIfFLSER WITH ECP-R TYPE 3 (LAY -IN) N© 14'114' PECK WITH 14' =ARE 114' 80110 ADAPTOR. CONTRACTOR PR0/IDEOr. 1. TERM ' L 3. %RAP ALL NEW SUPPLY DLCIS WITH IIQLAI I0N, 2 IRO, THICK MIN. 1 POUND PER 0.1. rT. DENSITY; MAXIMA( K VALUE Or 0.29; FACTORY- INSTALLED FIBERGLASS YARN MESH REINFORCED ALUMINUM FOIL FACING. DC NOT COWEAL TOWERS. ERS. 4. NEW FLEXIBLE DUCT LENGTH SHALL 1631 EXCEED 6 F1 NC SHALL BE FREE OF KINKS AND SHARP BENDS. 5. BALANCE AIR VOLUME Al ALL CEILING DIFFUSERS AND CALIBRATE VAV TERMINAL UNITS FOR NEW MAX. CF1 AS SHAW WITHIN CLOUDS. BANISH BALANCING REPORT TO BOEING CONSTRUCTIO4 MAJACER. 6. FLEX DUCT SHALL BE 'TNERMAFLEX M -RCS'. 7. DUCTWORK TO BE GALVANIZED STEEL IN ALO RDANCE WITH 5i4Ct4A SIA OAJRDS. DO NOT USE DUCTBOARD OR LINED DUCTS. D 6. MATERIAL A INSTALLATION SHALL COFOaM TO ALL STATE AND LOCAL CODES. CONSTRUCTION NOTES: [3> POINT OF CONECTIOH Cr NEW GALVANIZM SHEET 1E1AL DUCT 10 EXISTING ELECTRIC DUCT HEATER. rIELO VERIFY PEE PER FlaQUIRED FO [11 MECHANICAL i. g'ELECTRICAL ! I7 PLUMBING 1_1 GAS PIPING CF T DIVISIO 11t111d ^ 1hr: to er r' does : r.::.�pted copy r: , : ov Dato Permit No. 905064 2M10 EB11 1. .17 V 7- 100 -2N1 C 40026110 11 iCX ., , I1� �� 1 1!•71• =4 ' 1 1� if/'A` � A o..�.- S� _ j IIST �� �,�j 6• RE URN IR SER FROM FI T ► OOR 0 0 nom MEI MIN i1- 4 0. TITUS 116A FF DIFFUSER WITH 6' NECK, VOL. DAMPER TYPO 3 FRAME 4 125 FINISH (TYPICAL UNLESS NOTED OTHERWISE) BOEING !• FLEX TYPICAL SS NOTED OTHERWISE) TT TRAHSrC GRILLI 4 (96(60.455 .RAPER DUCT TITUS 5OF (1 ICAL) ;S LEGEND: CITY OF Tl'l(WlL APPROVED FEB 1 '. 199a / AS ; i e�U !r.. /.4b U', LING D1 ITS ARE TEAM MASTER KDCL 57BA UNLESS 0TH ' •TED. DUCT HEATERS ARC RE001 INC MODEL R.