Loading...
HomeMy WebLinkAboutPermit M98-0027 - BOEING #11-14City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0027 Type: B -MECH Category: NRES Address: 2925 S 112 ST Location: Parcel #: 092304 -9155 Contractor License No: HERMAC *217NT TENANT BOEING #1.1 -14 2925 S 112 ST, TUKWILA WA 98188 OWNER BOEING H &M ASSOC, POB 3707 M/S IF -09, SEATTLE WA 981214 CONTRACTOR HERMANSON CORP. Phone: 206 575 -9700 1221 2ND AVENUE NORTH, KENT, WA 98032 CONTACT LARRY RUFF 1221 2 AV N, KENT WA 98031 ******************************************** * * * * *k * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: ADD NEW DIFFUSERS, RELOCATE THERMOSTATS, NEW DUCT WORK AND AIR BALANCE. UMC Edition: 1994 Valuation: Total Permit Fee: * * ** ************* ************************* * * * * * * * * * * * * * * * * *,r * * * ** * * * * ** Perm t Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other, state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this ilding pe it. Signature: a0, /t _ 0-tajt Date: Print Name s _ _ it l __ Title: AC�„ Vt MECHANICAL PERMIT (206) 431 -3670 Status: ISSUED Issued: 02/19/1998 Expires: 08/18/1998 Phone: 206 - 575 -9700 800.00 42.81 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Project Name/Tenant: 17D. 1 - IL - Description of work to .e 1. Value of Co truction: t noo - Site Address: - Cit State /Zip: Tax Parcel Number Property Owner: DO � �� Phone: Phone: Street Address: 1 Bad 3 S ity State /Zip: Fax #: Contact Person: 1 . 4 4 . 14.1 0 Sewer 0 Metro Phone: Street Address: 12 'Z. t! � ity St to /Zip: �Ud � d b 2 Fax #: Lo& • - 515 - -e l Soy Contractor: n' , �� U (�d. &fk Phone: SOO -575 c -Cc Fax #: 2 — 57 �7 Street Address: LoS l� Ci y Sta /Zip: 1 9� Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND'APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to .e 1. done: A r /eW C 1 cet& t INC a . 'fik u,A,p -.1 WS i f ek0 - t. i0 . A Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and story a location on se arate 8 1/2 X 11 a er indicatin uantities & Material SafetzData Sheets ❑ Above Ground Tanks LI Antennas /Satellite Dishes Bulkhead /Docks Commercial Reroof ❑ Demolition ❑ Fence OlVlechanical ❑ Manufactured Housing- Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY. SERVICE BILLINGS TO:'" Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Name: Address: MISCPMT.DOC 7/11/96 CITY OF 'TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 • R STAFF SE ONLY Project Nurnber: Permit Number: M16 Ooa1 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. WATER METER DEPOSIT /REFUND BILLING: APPLICANT +REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # Size(s): ❑ Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): Est. quantity: gal Schedule: El Miscellaneous ❑ Moving Oversized Load/Hauling ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft grading/clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 2 11.46 Date application expires: �- I1- fa Applic by: (Initials) BUILDING * ER OR AUT ZED AGEN Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or - width which exceeds 2:1 Submit checklist No :. M - ' . . El Signature: / \ �N1P1, �i1 I P 1 1 I - Dater _ I �1._ c � I El Bulkhead /Dock Print name I �� \lC c (11- 1 ( c r 1 Kr, P ono r r ;l4, -57; - l -7(X`) Fax ? S - (- 1E - 00 Address; cal nn l M Ali n 1 ('.t t ,_p / t ! Land Altering/Grading /Preloads Submit checklist " No: M 2 Cry /State/Zip' �� 1 O c- — j.' 0 Zv , 46[ )? . Loading Docks ALL MISCELLANEOUS PE APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING: ➢. ALL URAW1NNS0,SKALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢° BUILDING SItE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,:or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permlt'applldation and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. t F MISCPMT.L OC 7/11/96 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW El Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or - width which exceeds 2:1 Submit checklist No :. M - ' . . El Antennas /Satellite Dishes Submit checklist No M El Awnings /Canopies - No signage Commercial :Tenant. Improvement Permit " . El Bulkhead /Dock Submit checklist : No ` M El 'Commercial Reroof ' Submit checklist < ', No M 6 i n Demolition • Submit.checkiist : No, :M 3, M 3a El Fences - Over 6 feet in Height Submit checklist No M -9 Q Land Altering/Grading /Preloads Submit checklist " No: M 2 El Loading Docks Commercial Tenant Irnprovement Permit. Submit checklist No: H-17 El Mechanical (Residential & Commercial) Submit checklist : No ;` M -8, Residential only - H- 6, -H -16 El Miscellaneous Public Works Permits Submit checklist No: ".H 9 E Manufactured Housing (RED INSIGNIA ONLY)". Submit checklist No: M El Moving Oversized Load /Hauling Submit checklist `" No " M-5 El Parking Lots Submit checklist No: M -4 - Eli Residential Reroof - Exempt with following exception: :If.roof structure; to be repaired or replaced Residential Building: Permit, .;" Submit checklist ; 'No: M -6 El Retaining Walls - . Over 4 feet in height Submit checklist No :. M El Temporary Facilities Submit checklist :"', No M -7 El Temporary Pedestrian Protection/Exit Systems Submit checklist No :." M 4 EI Tree Cutting Submit checklist ; No M72 ALL MISCELLANEOUS PE APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING: ➢. ALL URAW1NNS0,SKALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢° BUILDING SItE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,:or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permlt'applldation and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. t F MISCPMT.L OC 7/11/96 Address: 2925 S 112 ST Permit No: M98-0027 i Suite: Tenant: BOEING #11-14 Status: ISSUED; , Type: B-MECH , Applied: 02/11/1998 Parcel #: 092304-9155 Issued: 02/19/1998 111****Ocklelick.14.k*********************Ot* A-h./€*4444*** k*** k klitlilch k k******************* , Permit: Cond i ti ons : 1, No changes wi 11 be made to the plans unless approved by the Architect or Engineer ansi....,the_tuiswi 1a Building Division. 2. All permits, inspo.„9 , ,dtk.:;?i00 - S76,ild'i s a pp ro v e d plans shall be a v a i 1 a b 1 e at th.e p r i Oi- t of any con - struct ion. , are to ber7sMO!AAAned and ava i 1 - ab 1 e until ifl 1 inspecti approval fill s, gr 2 3. Al 1 conAk 6; Ct Lon; tdAtbke done In tonfoOpernqe Wttfiskapproved ' 1' p1 ans re4u triel4ents of , the Unl form' 146 1,0 ng \'0400 (1994 Ed i t On) as a iiie iid od , ,Un i f eri A g eha n4 ca T , 64e e (1 t .45'0 'Ea i t i on ) and,./;,y/gShtnil'eon'St.ate' Energy / Code ( 19§4 Ed ii1,4' W ,t, '1:s, !„ 4 Va 1'40 t'r of, P e r 0 b . Th e k I tt S Clan ce of a ') e rm '14'lo r a POk, a 1 of ,,, .,,.- R440 s v spec i f teat ionS,4and cotil6Itat ions Ala 1 i not 0e4: str'ue8 to be,, per'plle.'"f or an approval of A ank'v i keit ion !O' any , :of the pro 0 s i ons:y bu i 1 ding code di), o r 4T ari\c k , ,06 t h e r d i tia n c e of the 16i cA: i on . 'No permit poO4vm t g to , - ,..1 sions ilAgi ve aothori ty to i o 1 a tia or carice 1 the pray i /of Cci ir ... =, . ' -; Mcode shall be ya 1,Iii, CION REQUIRED ON 51.- INSTRUO IS 51TE FOR THE ' . .i . ..,,, , ,-- ., v ri ■•+ 4 A i i -g BUILDING INSPECTORgi' REVIEW '' 1 1 ' ..,.., 1 bri E ek„t0 t„a 1 , permi ts' Oa 11\ be .40 tAl naCtii rough the Washyn4N4 ete t Di qi ,.,, tdril of '--1511.1& and 0 1 pdifs.e'r i es; and a 1 1 e 1 d'Efi1 ca „ '-' , t ' '' q k 0' 4 orie'W1 1 1, be - 16spectedrby that,"'age04,P (248-6630 ''.- , ...0.::4 '-..,.- it (' l -' 't ‘ ./.( ..Y.4". i )17 , , 4 ' '044c.sti t? jet o 1 '04, N ,g 4 , par , t V I ' \ • f to 1, '''‘ ---,.; \ ,v, 1,-,..40," t4. tit •••:N CITY OF TUKWILA lb C.-. 4i rp 9 "41.. • • • • . ,•• , • • , PLAN REV Pernoti(- IEW / ROUTING ACTIVITY NUMBER M98 -0027 PROJECT NAME BOEING BLDG 111 -14 PARTMENT: Ke Yl STAMPING � KING DIVISION �II ION E FIRE PREY ON ❑ PLANN MSION El PUBLIC ORKS ❑ STRUC E PERMIT CO RDINATOR DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE ❑ NOT COMPLETE ❑ COMMENTS TUES /THURS ROUTING: PLEASE ROUTE 11 NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS INITIAL C:ROUTE -F DATE APPROVALS OR CORRECTIONS: (ten days) DUE DATE 2-26-98 APPROVED ❑ APPROVED W/ CONDITIONS ❑ DATE DATE DATE 2 -11 -98 DUE DATE 2 -12 -98 NOT APPLICABLE ❑ NOT APPROVED (attach comments) ❑ DUE DATE APPROVED ❑ APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Cerdficadon of occupancy required. ) J ".. :?REGISTRATION NU1vrBER • 'EXPIRATIQN:D ? • REGISTERED AS PROVIDED BY LAW.AS'A; .•r r KI Q • Yf • • • SIGNATURE ISSUED BY DEPARTMENT OF LABOR AND INDUSTRIES • _ lF.�+1Ca?r��� L..w�; b' • y r �3.� . • ri t ..: i:3 ' Y.. � •.' 7L C „S * t ' • L ► � � V l( ''.. ✓+ cal �7A ♦ Y 1 �.: •N "l0 % : ;. ., \4 �• • +. •, � �yM't : • r •Y �►!• 11 !} . .!,� 7:•..r a,:'�.�h '��i• 't• ! . ••Yy' Account Code 000/345.830 000/322.100 Permit No M98.002? Type: U-MECH Parcel No: 092304-9155 Site Address: 2923 S 112 ST Description PLAN CHECK - NONRES MECHANICAL •- ' C a 41 * ** *A*•k** * * * *kh*kA **•k #k* *•s .TY OF T'.UKWI:LA, WA • TRANSMIT i•fi *Ah•k**k * **•:ti.* *•A *A**kk k•*•1.4 *^k4A• *• *k•k* * * **kA.4 ^4A* *:;•*kkk%4* **•k '6'ANSMtT Number: ,R9'0071 E, Amount„ 42.81 02/19/98 10:58 Payment Method: CHECK Notation: HEIH1ANSON CORP Initt IILH MECHANICAL PEIt111T Total Fees: 42.131 This Payment 42.81 Total ALL Pints: 42.81 • 13a'lanceu .00 e1 * *k *** * * *•A * * *AA *•A• *7E *;VJ * *Ak * *•*!1. *A **Ah * *A*Ah• **kA *4 *A * * *• * * ** * Amount 8.5 4 2 5 Project: ed 11- i / T of inspection: Address: , .,, l —Date called: Special instructions: Date wanted: �r ✓_-� am ! � . L LD Requester: Phone No.: 1 Inspector Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 .•�;1& / 1 :2L Corrections required prior to approval. Date: naaili PERMIT NO. (20674 _ / . /r' 411. $42.0 • REINSPECTION U EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project 0 II - f Type of inspectip � o 0„.... AddressZG z „S” 1 12/ Date called: '2.- I( Special instructions: Date wanted: a.m. Requester: � S Phone No.: 51 J C , 9 ,,.' INSPECTION NO. INSPECTION RECORD Retain a copy with perml�� " �Z7 PERMIT N . (206) 431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. LJ Corrections required prior to approval. $42. - INSPECTIO / FEE REQUIRED. Prior to inspection, fee must • be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. I Receipt No.:' iks A Date: Pr,cf; n i n (1_ I(J , Type C... tiil�� 5 r ! 5 f, Date called9 Date wa. - ( t ciir Special instructions: t rot Floor - no �� •: � r433 q Requester: Phone No.: INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: I Inspector: rl INSPECTION RECORD Retain a copy with perm fl'( ZS "ac PERMIT NO. Corrections required prior to approval. Date: Date: (206) 431 -3670 GI..� $42.00 REINSPECTION `FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. Receipt No.: $ 42.e1 YES READY FOR ISSUANCE BALANCE DUE STATE CONTRACTORS LICENSE RE UIRED? IS THIS CONTRACTOR IN THE SYSTEM? NO • • A1'PUCANT CONTACTED al11111.11111.11111 DATE CALLED CA.141.ED BY IMENEIMMIN Sent by: bLR•JOHN GRAHAM la - • I 1j31N3O LtV4U34 • 8661 t t 8A 11V1 •I(: jj3c1 d'IIom 40 A110 03A1303 a oNo 11C1S:A N�II'il?J 02/06/98 4 :23PM;J jx #9; Page 3/3 'VW! ?IV.i I:)) (: ;X17 !(IIAOt•Id C.I'1:3c`1 £ (7!4 0009 ?(11)11 ''/511\1 V!'.1 ,, 1• WY 1.Jli.l ONI 11 l.) 1r(Xt/ , (l Vd(.1 ?:'.IcJ C J 3 L..) N (.1:1S C ION Nnnc)� S >i ?!OM.,:)f1(J 1A1V J:••.NMO(1 (1NV / x (:)f-I AVA 1:)NV iv,1.J,J 'NMO1 (1NV '131'1(1 01 NI dV: ,,;.)1 l ;)(ICa XTi..l „ 1. 1 .J(.Iln(;•'Jc.I ' I11 VVf'I (/1. x z / t X Z/1 IV'f 10 :1 sllll I .1 I 1+ ?1(..) N ?If r: 1 X k(. '(1TAO.-.Ic.I :.i)•jl .� I 1 ?I.r) wf lN1iNf)'lb' c'/ ! :K 6/1 X 771 lVl1O.l o log (.: ;f 1.11 I II?•J!) N?: 1rI.1. -1?I � i X V Z (11nC)dc.1 'NOI.LV.)01 IV I IVM M.•IN N(.) 1V1 1 . ' I ;VI` V1 1 (INV IAC)VY :I ?I ' NMO) Ir; '_;`, IL.l`:; >i:).JN 3 )r 1' IJ>1 ' . Jfl(;I x.: ►:� ._ : l ,1NV '2� id'AV(i C)NI.)NV v i 'y �`:f'1 I�I(•i M.aN 'lc.�lnO ?ici .:. nMC)I Is NuIIv :)()1 ..71 Iv 7iU is l?: * ';,:J/.1.) ;'JNII I IN?If 1.1 SlN ! `.;,c. ;; 11 1•i 1 IM J:5N. 3 i i±LNl (110AV 01 U :: 11.110J?1 11 IV 15 .`)NI1 • ;IX �`;Iv I:)r1 'IViJw LJ�N`> MJN '(J i.IV :)l JNI 1N I :') ;I ;;)(1(1-1;1 " ::,Ic1 1 :)i el ,`:`.1 i,Jl::l 1;)NV •NMOI• -IS NO11V:)01 AA.::N ()I J.V1`:•; •.l. I�:,'X� .. 11VDC)1'•1 I 'NM()I +:: `:,V (1.:41V: (aNV N; IJ.IM ,:)01.1 X I1A CINV 'i 1`.�i l`.IX.I 3;:)V i:J :) l .I I N N ( - ) I ! NC)'�) L. k. re: C.1 ( -4/ • • , ,;f If I I . .. ....... • I:: •t:: itimi; 1:11/ 1.• 1 [ LI ..... .. n ) al / • R1 ( c.) //:.•71! 1 i • 4 0 20 12 DB N 1 1 28 0 C 280 36X12C OS AIR DAMPEE 1O"8 �e LOe� L 275 CFM '\ � =1GN NEW 11 '. FACE;?; ITH EXIST COLUMN1 I I; !, 4(LI'755 " 4 D 7 REVISION 6! 11 "AS— BUILT' BY WOOD /HARBINGER B� DUWAMISH BACKFILL PH.11 #979167 MWS JGA APPROVED 200 CFM DATE SYM 12 -31 -,2 1/15/9 OSA RELIEF 36X12(1/ 66/3 SHAFT AIR RELIEF RA SHAFT AIR DMPR & FIRE REVISION AC -3S 120/36 I,I -RA =flAtf ;�Q� MATCHLINE SEE SHEET 3M11 w APPROVED _ J I_ e DATE DJA cH MWS ENGR CH€C7ED A PPROVED APPROVED SCALE: 1/8" = 1' -0" ,$0'3iritF TITLE NEW SHEET- METAL DUCT. LEGEND CONSTRUCTION NOTES REPLACE EXIST DIFFUSER AND FLEX DUCT WITH NEW, SIZED AND LOCATED AS SHOWN. RELOCATE EXIST T —STAT TO NEW SHOWN. REBALANCE DIFFUSER TO PROVIDE REDUCED CFM INDICATED. RAISE EXISTING T —STATS IF REQUIRED TO AVOID INTERFERENCE WITH THE SYSTEMS FURNISHINGS (TYP). RF�0 ATE EXIST DIFFUSFR TO LOCATION SHOWN PROVIDE NEW DIFFUSER, BALANCING DAMPER, AND FLEX DUCT. REMO /ELAND— RE!NSTA5L T "STAY ON NEW WALL AT SAv tE LOCATION SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL _LSCTRICAL S'LUMBING CrAS PIPING • OF TOK(WILA t ,e,LDING DIVISION KEY PLAN SCALE: NONE THIRD FLOOR PLAN =HVAC BUILDING 11 -14S MECHANICAL MASTER COL A —G/1 -7 — CEILING DIFFUSER, 4 WAY, 10 INCH NECK RELIEF GRILLE, 24x24 RELIEF GRILLE, 24x12 FLEXDUCT 0 THERMOSTAT s 1 S VOLUME DAMPER i86 stand that the Plan Check approvals are , ct Lo er ror s and OMISS■on=a nn approve. Of ;1•�eS not author zt, 1 1E 'H:c0 c. code or ord naoc cr:,l';1 ot cun- - s c Y Of approv t aos ackTvarged. By �CUY1 (ak_Q 1 Date Permit No. M Cie — 1 SHEET JOB N0. DUWAMISH Dwc ND. FILE COPY Wet-Dori SYM60L 0 DATE_ crriN FEB 1 1 1993 PERMIT CPNTEr COMP N0. LAST REVISION 3M1 00000 11.14S-3M10