Loading...
HomeMy WebLinkAboutPermit M98-0057 - BOEING EMPLOYEES CREDIT UNION (BECU)Tx)01 GIvIcte aRedi4 Onto City of Tukwila ( (206) 431 -3670 Permit No: M98 -0057 Type: B -MECH Category: NRES Address: 645 ANDOVER PK W Location: BUILDING #6 Parcel #: 262304 -9075 Contractor License No: COMFOP *064D2 UMC Edition: 1994 MECHANICAL PERMIT Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila,. Washington 98188 4 S/F Status: ISSUED Issued: 04/14/1998 Expires: 10/11/1998 TENANT BOEING EMPLOYEES CREDIT UNION 645 ANDOVER PK W, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTRACTOR COMFORT PLUS Phone: 206 251 -9840 PO BOX 913, KENT WA:98032 CONTACT HERB JACKSON 6617 S 193 PL, #P -105, KENT WA 98032 ********************************************* * * * * * * * * * * * * * * * * * * * * ** * * * * *** Permit Description: INSTALL 3 NEW VAV BOXES, 24 NEW'PNUEM. T /S, DAMPERS, 2 EXHAUST FANS, RELOCATE AIR DISTRIBUTION. Phone: 425 - 251 -9840 Valuation: 27,'- 755.00 Total Permit Fee: 88.75 * * * * * * © * * * * ** * * * ** *** * * * * * * ** ** * * * * * * * * * * * * * * * * * ** ** 4-14-10 Permit Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature:1 _,_, Print Name :_ E2Q _ _E" Date: Title: Q3 � This permit shall become null and ,voidi,f',,th;e; work is not commenced within 180 days from the date of issuance,.:or i.fthe work is suspended or abandoned for a period of 180 days from the last inspection. Project NamefTenaip Description of work to b done: -e►(( 3 n&& (f / V bout 2)1 othx7 7+') 0 1. 8/ I S c e.46, .2.- aic t cc u. + d rreJcc cc4- ca sf ri buckevl ,.� Will there be storage of flammable /combustible hazardous material in the building? ❑ yes t_Y no Attach list of materials and storage location on se•arate 8 1/2 XX 11 paper indicatin uantities & Material Safety Data Sheets Value of Construction: Site Address: • L. �.• • AK • . ✓ 1 • _ .. City State /Zip: Tax ParceiNumber: 2 °Z A a0 Property Owner: Address: Phone• CZ 5 2I20 ,.._., ( ot42 IQ P - UeVe-�41!) Street Address: -••• . •) - ■ &- &t ' 2=zc' . d IN & • . i.. Cit State /Zip: r: (O Fax #: Contact Person: P• •ne: z5' Z-5i —' 0 ■E Street Address: 7 ( oS City State /Zip: Z- Fix #: (4 2a ZS' 98 . c 9 3 - ; ,tiL . Contra 4 ÷ ( P r-5) 1 -,e430 Street Address: 17 5'. 1331) tf. - 'f OS K �v td . City State /Zip: F x #: Q 42? � Z51— 9811 Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BYAPPLICANT) Description of work to b done: -e►(( 3 n&& (f / V bout 2)1 othx7 7+') 0 1. 8/ I S c e.46, .2.- aic t cc u. + d rreJcc cc4- ca sf ri buckevl ,.� Will there be storage of flammable /combustible hazardous material in the building? ❑ yes t_Y no Attach list of materials and storage location on se•arate 8 1/2 XX 11 paper indicatin uantities & Material Safety Data Sheets 71 Above Ground Tanks ■ Antennas /Satellite Dishes t_1 Bulkhead /Docks Commercial Reroof ❑ Demolition ❑ Fence ❑Kechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application Channelization /Striping Flood Control Zone Landscape Irrigation Storm Drainage Water Meter /Exempt # ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application ac led: ■ Wal MISCPMT.DOC 7/11/96 CITY OF Tr 'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST. FOR MISCELLANEOUS. PUBLIC WORKS PERMITS' ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: Cl Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public Size(s): 0 Deduct 0 Water Only Date application expires: - z - 1 gal Schedule: Applic: 10 taken by: (Initials) BUILDING O N: - "R AUT ORIZEb AGENT: El Signat�co: Submit checklist No: M -1 J Date: Commercial Tenant Improvement Permit Bulkhead /Dock Print name: �' " 4 .6. - 4I k5d''1 h 7^98 - i 0 IgiSJ ZS�i' "'487 Address: Q,(1 c50. ! (93 . f OS City / date /Zip: 1 , IAJ 4. c:18 03Z- 71 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2 :1 PERMIT REVIEW Submit checklist No: M -9 El Antennas /Satellite Dishes Submit checklist No: M -1 J Awnings /Canopies - No signage Commercial Tenant Improvement Permit Bulkhead /Dock Submit checklist No: M -10 © Commercial Reroof Submit checklist No: M -6 Demolition Submit checklist No: M -3, M -3a in Fences - Over 6 feet in Height Submit checklist No: M -9 O Land Altering/Grading /Preloads Submit checklist No: M -2 0 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 Mechanical (Residential & Commercial) Submit checklist No. M -8, Residential only - H -6, H -16 Submit checklist No: H -9 71 Miscellaneous Public Works Permits 71 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M -5 Moving Oversized Load /Hauling Submit checklist No: M-5 71 Parking Lots Submit checklist No: M -4 E3 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 71 Retaining Walls - Over 4 feet in height Submit checklist No: M -1 71 Temporary Facilities Submit checklist No: M -7 El Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 0 Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PE IT APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: �� f: t "fir ".� ' ➢A` IXLW OR A1uvINGS SHAi1.L BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ Bl1IL614 SPT til.'ANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. • MISCPMT.DOC !7 /i .1fr/96 0 No tiot ' CITY OF TUKWILA Address: 645 ANDOVER PK W Suite: Tenant: BOEING EMPLOYEES CREDIT (UNION Type: B-MECH Parcel #: 262304 -9075 Permit No: M98 -0057 Status: ISSUED Applied: 03/20/1998 Issued: 04/14/1998 • k• k**** k• k• k• k• k* k• k• k•** k*** k* k**** k* k*** k•*** k*• k** k•k** k• kk •k **** **•k***** Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the „Tukwi Building Division. 2. All permits, inspection., :. n % >,; .j+p,roved plans shall be available at the ,1,ob s =ite pr. ior'r to tfiestar.. of any con- struction. These > iocumentsl are tot maintained., and avail- ; , able until f i n al ;ins e c t: i�d n ; a p r o. granted, t� p va;1 i s , -.�.; 3. All construction to ,be done : confor.mance with approved plans and : r;e.giiirernents.: of the Uniform Bui'id•ih+ Code`'.(1994 Edits o ;��;a;.. '�`anretlde�i,> Uniform '`f'�ec'f }ani�c:�1,, Coii�e; "0 994. Edition), and Washingt,on State Energy 'Code 9994 Edit ion) . 4 . Va l i d i,ty/of ' Permit . , ' The i i ssuance: a permit orsa'ppr *ova;' plans, ,pecifications, and computa t1ons shall not ;be con- strued%! to, he a per•mi t r for •or an approval of, any violation: of any of '''the provisions of ' :t•he, bu i 1 d i ng code or':.of` °%any ,;.. other ;'or.dinan ordinance of the:.,aurisd�i"•ction; No permit pr es'umi'i g �: r. giv,authority to viol'ate ror,icancel' the provisions: >of code sha 1i ''be: valid. MANUFACTURERS INSTALLATIO N N ? INSTR UI.�l'I�Of��- , RE�►UIRED ON;•:,I'1'E ” FOI�!THE BUILDING INSPECTORS REVIEW; 5. MA 6. Elec al. Permits. shell b�e:obta,lr�e through the Washington State Division of Labor arid Industrie. anti" all electricaii'y. worN; wi l l be -Inspected :by t.ha.t`,agency , (248 -6630) . DEPARTMENT: B (ing Division, P' 'c Works APR- ROUTE.DOC 1/98 C PL 1 2 ,ajia COoba. COfiu AN ACTIVITY NUMBER: M98 -0057 PROJECT NAME: BOEING EMPLOYEES CREDIT UNION Firer vention Stru ral DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ik Incomplete E TUES /THURS ROUTING: Please Route ❑ APPROVALS OR CORRECTIONS: (ten days) Approved E Approved with Conditions E CORRECTION DETERMINATION: Approved E Approved with Conditions ❑ Comments: Routed by Staff E (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: REVIEWERS INITIALS: DATE: 3 -20 -98 Plannin Division ct.$ Kermit oordi ator DUE DATE: 3 -24 -98 Not Applicable ❑ No further Review Required DUE DATE: 4 -7 -98 DATE. Not Approved (attach comments) [l DATE: DUE DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: t • 7007074, WATWOR --7 C.P.444$ a-? • COMFORT PLUS.- 6617 S 193RD'OK STE P 105 . - KENT,WA . - -. 1 _ - -'--: / 1 : i - • . • if ._ _ -.. : •.• ,, .• :: • :-.• : - ... - .-, :,. . :.. . , • :. . I F625-052-000 (8 DEPARTMENT OF LABOR AND INDUSTRIES • REGISTERED AS PROVIDED BY LAW AS 'CONST.CONT SPECIALTY AA AF fac: count Cade 000/345-. .830 000!3:22 100 g •1)�e:yp:.5 Description PLAN CHECK - NONRES MECHANICAL •- NONIiES •kk ** **k:kA * *kA• *•k * ***k** *** ** *k•4 kkA *•A *k.* *Ak•A.**k **•k•4Al:k.A• •A• **A** CITY OF TUKWILA, WA TRANSMIT:. * *•kA *A•k* * ***kk•k*:t'k;% * *•k•** A ** *A* X 4 *A ****.k•k*•A*•k **'4,V k**A *.t kA * * *+t h** TRANSMIT Number: I970.0746 Amount: .86. 75 04/14/9 15:56 Payment_ Method: CHECK Notation: COMFORT PLUS - Init: OLH Permit No M98-0057 Type~ p -MECI4 MECHANICAL PERMIT Parcel Noz 262304 -9075 Site Address: 645 ANDOVER PK lit Location: BUILDING $16 Total .Fees: Sts «7a This . Paym 3 ent 8 .75 Total .ALL Pmts; z 06.75 " Balance:. .q0 A, t• A*• l: a* A*** 4- 0, A*** A• k• AA* A*: A• Ad***• kA+. AA*A***** 4A *AA•"A*•. *•A * * *4- kir. * *A•k• * * * Amount 17.75 71.00 Project:�� Type of inspec 'orf -- Address tcs Date called: Special instructions: Date wanted: G 1 ( �f ici 0 Q . a.m. prim. Requester: 1 Phone No.: i Inspector: Approved per applicable codes. .ftvw,tr,. e4ce z'ziait !, s; :K't!S':' INSPECTION RECORD Retain a copy with pe INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Corrections required prior to approval. Date: L4 S 111 -.ms7 PERMIT NO. (206) 431-3670 Li $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: Project: Type o InspQc 0 g Address: ( 5 A . v , Date called: SIZ7 Date wanted: x 128 i�E 5 .m . Special instructions: Requester: Ls Phone No.: Date: 512411 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.: :74tt"aT1 ' ^aS7/}r^v -- 4 wvez mo7.' c'recy"' ayse!_;tri Yi' •,n INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION RECORQr- Retain a copy with penik.J PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Project: c~k CA X FFS ceri T UMcN Type of inspection: �.-!�, ,` L. l...) 1 , - r I, • _ Address: Date called: S pecial instructions: Date wanted: 4 . _. f iS c c'.7) Requester: 1 c ) c%LA Phone No.: t i4 5 .:;)I- eiltlo 44714,104 .v M:wwvow,No vr. yid'N`iIii" ,«x, ,7.4 ,140. ar.v..14.11' 02:, V :`.."i.,`.. :I'44 47^, a; {A;Z a INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 A pproved per applicable codes. CO MENTS: d7rte 7,G� 4 /,.„ I Inspector: I Receipt No.: INSPECTION RECOR Retain a copy with per n1—. ,k1 ;0057 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: 5 • ri $42.00 REINSPECTI0I4 REQUIRED. Prior to inspection, fee must be paid at 6300 SouthcenterBlvd.; Sulte 100. Call to schedule reinspection. Date: Project: e T e of i peckon: A re � - '1 `7 Da e led: 4 92, ` ,. a.m Special instructions: --Vdi (47 Date wanted: / Re COMMENTS: Inspecto Receipt No.: Y. ^n f , 4— r it hka ��f` yt f., �' � ifr.. ri:= 4:=ikl'itti': "t ��ifb+Retlf+ >X1 °_ INSPECTION RECORn Retain a copy with per INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Date: 2a)57 PERMIT NO. h• 206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. (� S42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i}:: �::. y:::•; i2•:.i }:•' { i}: :: i:•: 2 ' : : :::4 ; :•}::;::: i:}:: : v, ,:,., : :•''i'.V,• }';:;:•.`, ::•iii: } }:r { }::::i:•r:"i:GTTT::: •:. :.::::�.; :..; ,.. .�:::. {.::•::it:: :.. : , .. .... N . t �� C on #ac�.:F . • ::..... �...:. ,.:.:::2:2•:,,. .....:.::.::.:: <•;......::. �........: Y::::: •::•... l.•:viv::v...w:::........ ,, .... ::: iiii 4 'i { : :2T •{:+.: : vii't:2:22 ?:; +..:: {.,:;222.:4:.: {.... ..... 4.4 .... ::::::'W:::::::•51:*:. .''':::.:•••::.:. :::.::::Y}:•v.• >i }i:2T::: ::.'::.v:•;� {�:4+.ir •} :;uu.: ::• J {4'.T; }i } : ; i ' T.. :;:;. {•;.:i: : . } •• 2 . . . : •: {k• ::.• + + is ! { rT .. i. :•::•$.. •: �4:+.....;:.%•:::•:::•:•:.:,..::::•:,: i.4A ..... : +. .,, .v.r• {. 1 / 1 . • i / 1 i . v d_ , • a Balance Due: $ Need Current Contractor Registration Card: ❑ Yes z r No Need to Enter Contractor Information in Sierra: J Yes e No [ GREENIECK DAMPERS AND LOUVERS Application and Design Model CFSD -23 is a combination fire smoke damper UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model's operational ratings, of up to 3000 fpm and 8" w.g., far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings — providing an extra measure of safety. Model CFSD -23 is rated for air flow and leakage in either direction. Ratings Fire Resistance: Leakage: Pressure: Velocity: Temperature: Standard Construction Frame: Blades: Seals: Linkage: Fusible Link: Axles: Bearings: 5 "x1" galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 17" high to maximize free area and performance. 16 ga. galvanized steel, reinforced with 3 longitudinal structurally designed vee's. xtrudod silicone rubber blade seals. Flexible stainless steel jamb seals. Concealed in jamb. UL listed 165 °F. lie' dia. plated steel. Bronze sleeve type. Size Limitations Minimum Size: 8" W x 6" H Maximum Size: 24" W x 24" H UL rating of 1 hour for corridor ceilings UL 555S leakage class I (to 8 in. w.g.) Leakage rated in both directions 8 in. w.g. - differential pressure Dynamic and operational rated to 3000 fpm. Rating Is for airflow in either direction through damper. 350° with all actuators. Higher temperature ratings with some actuators. Fire tested to 1800 °F. C1TY P� I �U�D AP . APR 1 3 1998 ruJ •lVIL✓ Optional Features: • Galvanized steel sleeves. • Stainless steel bearings • OCI (Open closed indication switches) • 212 °F fuse links (other temperatures available, consult Greenheck) • TOR (remote override of 165 °F closure. Allows damper to perform smoke management functions during a fire emergency.) • Electric or pneumatic actuators to accomplish smoke management and system functions. Corridor Ceiling FIRE SMOKE DAMPER Model CFSD -23 Steel 3 -V Blades UL 555S Leakage Class I Model CFSD -23 meets the requirements for corridor ceiling dampers, smoke dampers and combination fire /smoke dampers established by: National Fire Protection Association NFPA Standards 90A, 92A, 92B & 101 BOCA National Building Codes ICBO Uniform Building Codes SBCCI Standard Building Codes City of Los Angeles CSFM California State Fire Marshall Listing #: 3230 - 0981:105, 3230 - 0981:106 "UL CLASSIFIED (see complete marking on product)" "UL CLASSIFIED to Canadian safety standards (see complete marking on product)" Standard 555, 555S (Listing #R15439) c s �. "W & H dimensions furnished approximately 1 /4" undersize. CFSD -23 05.97 Qty. W H Fusible Link Temp. Actuator Model A Dimension' Sleevi3 Length` Ga. . • ,.: ,, ' f J,; • RECEIVED nrrY OF T UiWVila4 h1AR 2 0 1998 Project Location PERMIT CENTER Contractor Design Specifier [ GREENIECK DAMPERS AND LOUVERS Application and Design Model CFSD -23 is a combination fire smoke damper UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model's operational ratings, of up to 3000 fpm and 8" w.g., far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings — providing an extra measure of safety. Model CFSD -23 is rated for air flow and leakage in either direction. Ratings Fire Resistance: Leakage: Pressure: Velocity: Temperature: Standard Construction Frame: Blades: Seals: Linkage: Fusible Link: Axles: Bearings: 5 "x1" galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 17" high to maximize free area and performance. 16 ga. galvanized steel, reinforced with 3 longitudinal structurally designed vee's. xtrudod silicone rubber blade seals. Flexible stainless steel jamb seals. Concealed in jamb. UL listed 165 °F. lie' dia. plated steel. Bronze sleeve type. Size Limitations Minimum Size: 8" W x 6" H Maximum Size: 24" W x 24" H UL rating of 1 hour for corridor ceilings UL 555S leakage class I (to 8 in. w.g.) Leakage rated in both directions 8 in. w.g. - differential pressure Dynamic and operational rated to 3000 fpm. Rating Is for airflow in either direction through damper. 350° with all actuators. Higher temperature ratings with some actuators. Fire tested to 1800 °F. C1TY P� I �U�D AP . APR 1 3 1998 ruJ •lVIL✓ Optional Features: • Galvanized steel sleeves. • Stainless steel bearings • OCI (Open closed indication switches) • 212 °F fuse links (other temperatures available, consult Greenheck) • TOR (remote override of 165 °F closure. Allows damper to perform smoke management functions during a fire emergency.) • Electric or pneumatic actuators to accomplish smoke management and system functions. Corridor Ceiling FIRE SMOKE DAMPER Model CFSD -23 Steel 3 -V Blades UL 555S Leakage Class I Model CFSD -23 meets the requirements for corridor ceiling dampers, smoke dampers and combination fire /smoke dampers established by: National Fire Protection Association NFPA Standards 90A, 92A, 92B & 101 BOCA National Building Codes ICBO Uniform Building Codes SBCCI Standard Building Codes City of Los Angeles CSFM California State Fire Marshall Listing #: 3230 - 0981:105, 3230 - 0981:106 "UL CLASSIFIED (see complete marking on product)" "UL CLASSIFIED to Canadian safety standards (see complete marking on product)" Standard 555, 555S (Listing #R15439) c s �. "W & H dimensions furnished approximately 1 /4" undersize. CFSD -23 05.97 701113n m n e CI n omm� m .n a .1 n oe rc _NS■11■a■ _IM■■ ••R111 ii ilu i ■� ' � i • NMI 11 1111 ■■ss■s_■■_■_0 MI■__a_O MIMMI 11111tl0 55 1 1111 a. ■■■ ■ ■■ 11 1111� In 11 1111 4 5 . 2 11111 5.3 11111 _m■■■■ �iiiii=�iiiiiiiiii ••IIW/mMUNIM o ■_uIII__■■■■■■ lI / iIII ■0 1111 �1 11►1.7A I i ii lIII IIII MIA AINICII /MA 11=11111•11111=111111•11•11•11 1111111111111111111111111111111111 81111 181111 11•111110111111111M111•• NM MI10110 . . 07 4 .04 03 02 • 1111111I/111/M111 1111/A1111111 111111/41111 Fall t %1111 11111 11111 ��!• 1•••�1 In! 1111 I T' d . . i ) 0 i 2 3 4 5 87 8911 x 1000 PRESSURE DROP DATA This pressure drop testing was conducted in accordance with AMCA Standard 500 using the three configurations shown. All data has been corrected to represent standard air at a density of .075 lb /ft' Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. rervi:) Damper Size 12" x 12" pm Figure 5.2 Figure 5.3 Figure 5.5 E> E> 10 9 9 7 6 6 4 3 2 1 :8 .6 .7 .6 .5 .4 .3 .2 .06 .07 .06 .05 .04 .03 .02 5D 5D r Damper Size 24" x 24' 6D 5.3 5.5 52 4 5 2 3 4 5075910 x100 x 1000 Velocity rpm) CFSD -23 CONFIGURATION D= IW) (H) 3.14 CFSD -23 is available in 3 different configur below illustrate these different configuratio Configuration #1 - Fire Rate Actuator Fire Rated Ceiling r - - - -- - X 0 L J Grille (by other Configuration #2 - Fire Rate Actuator Fire Rated Ce ling r L L 'H' 'H' I Finished Ceiling Below Ceiling Grille (by others) Configuration #3 - Fire Rate Actuator 1 Actuator Space' Envelopes Sieben Landis & Staefa MA -220 Serie MA -230 Series 331 -4551 'X' Dimension 5.875" 7.5" Minimum Width 12" 13" (18" w/ options) Minimum Height 12" 18" 'A' = 'X' + Depth of Grille Consult factory if 'A' is greater than 9.5" -23 CONFIGURATION All with n CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille r 'X' � L H 1 � — Fire Rated Ceiling Grille (by others) Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling Fire Rated Ceiling Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Fire Rated Ce ling r L 'H' r L 'H' Grille (by others) 4 Finished Ceiling Bsbw -1 J I 'A' 5" - 'A' 5" i 16" 'A' r 43/4" Min. r Sleeve Length A Sleeve Length LPACE ENVELOPES • Consult factory for dampers under 12" high. 1 Options include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or extemally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or extemally. 'A' Dimension Standard Minimum Sleeve Length With OCI, RRL, or TOR, H dimension less than 10" 10 20" All other dampers 6 16" -23 CONFIGURATION All with n CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille r 'X' � L H 1 � — Fire Rated Ceiling Grille (by others) Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling Fire Rated Ceiling Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Fire Rated Ce ling r L 'H' r L 'H' Grille (by others) 4 Finished Ceiling Bsbw -1 J I 'A' 5" - 'A' 5" i 16" 'A' r 43/4" Min. r Sleeve Length A Sleeve Length LPACE ENVELOPES • Consult factory for dampers under 12" high. 1 Options include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or extemally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or extemally. 'A' Dimension Standard Minimum Sleeve Length With OCI, RRL, or TOR, H dimension Tess than 10" 11 3/ e" 20" All other dampers 7 Me" 16" -23 CONFIGURATION All with n CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille r 'X' � L H 1 � — Fire Rated Ceiling Grille (by others) Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling Fire Rated Ceiling Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Fire Rated Ce ling r L 'H' r L 'H' Grille (by others) 4 Finished Ceiling Bsbw -1 J I 'A' 5" - 'A' 5" i 16" 'A' r 43/4" Min. r Sleeve Length A Sleeve Length LPACE ENVELOPES • Consult factory for dampers under 12" high. 1 Options include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or extemally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or extemally. SPECIFICATIONS Corridor Ceiling Fire Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans, and /or as described in schedules. Dampers shall be classified by UL under the "Corridor Damper" listing with a fire resistance rating of 1 hour and shall further carry a leakage Class I rating under UL 555S. Each damper /actuator combination shall have a UL555S elevated temperature rating of 350 °F minimum and shall be operational and dynamic rated to operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specifier select one of the following) electric type for 24 Vac or 120 Vac operation OR pneumatic type for 20 psi operation. CFSD -23 Damper blades shall be 16 ga. galvanized steel 3 Vee type with three longitudinal grooves for reinforcement. Damper frame shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be Sintered bronze sleeve type turning in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tight seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Each damper shall be supplied with a 165 °F fusible link. The basis of design is Greenheck Model CFSD -23. e PROJECT Corporate Square LOCATTON Tukwila, WA CONTRACTOR Comfort Plus PRODUCTS Fan powered terminal units CY. C.. --�, Air Commodities Inc. All Ami HEATING • VENTILATING • AIR CONDITIONING EQUIPMENT Submittal Corporate Square F E - QUIPMEN7' PROVIDED Titus 1 By: Matthew Rybar March 2, 1998 Plisw 0041 e N3\\- ° 6100 Sixth Avenue South, Seattle WA 98108 • (206) 767-2600 • Fax: (206) 767-4815 • 1-800-875-2473 www.air- commodities.com cm OF TUK MAR 20 1998 pERMIT CENTER Unit Size Inlet Size A B C 1 D I E IF 1G Wiwi I J I K xiem M N i'Ailla Filter Size 0.8 6 '/. 6.4 2.7 2.0 4 '/. 6.4 2.7 5 '/2 5 'h 9.8 4.0 3.0 6 2, 3 8 11 10 2 '/z 2 7 16 '/r 3 14 6 '/r 12 31 20 1 '/i 39 '/z 22 x 14 10 7 '/z 8 6 '/z 4, 5 16 13 2 '/2 2 8 '/2 18 '/A 4 '/z 17 15 32 25 '/z 1 1 /2 47 27 x 17 12 8 V2 14 9'/z 10 7 '/z 6 12 20 15 2 1 /2 2 9 '/z 20 1 /1 5 '/z 19 8 '/t 17 34 '/z 25 1 /2 1 '/a 51 27 X 19 14 9'/2 16 10 ' /z All dimensions are in inches. Fitter size is for unit without attenuator For filter sue with attenuator, please see reverse side. Unit Size Motor Horse- power Motor Amperage Ratings 120/1/60 208/240/1/60 277/1/60 FLA FLA FLA 2 'Iv 2.6 1.1 0.8 3 '/. 6.4 2.7 2.0 4 '/. 6.4 2.7 2.0 5 'h 9.8 4.0 3.0 6 3 /• 18.0 7.5 5.6 TITUS® Submittal Terminal Units • Fan Powered • Parallel Type Model: PMFV • Pressure Independent • Pneumatic Controls Dimensions are in inches. D H A 5 } C Control Enclosure. (Omitted when electric coil is furnished.) FLA = Full Load Amperage, as tested in accordance with UL. 1995. All tan motors are single phase, same voltage as electric coil (wren supplied), with exception that 277 voltage motors are used with 480 volt / 3 phase coil (4 wire wye). Access Panel (Entire Bottom is Removesbie) (Please see reverse side.) 7 r K 1 r l Metal Controller Cover (Optional) I FP- PMFV -1.0 5 -1 -95 ❑ Metal controller cover. ❑ Hanger brackets. ❑ Mlcro.L0cTM Liner. Nominal Inlet Size Minus 1/8 Accessories (Optional) Check [e ' if provided. ❑ TITUS II Controller maintains constant reset span and start point, regardless of changes to HI and LO cfm limits. ❑ Induced air filter, 1" thick, disposable construction type. ❑ Fan disconnect switch (not availab veD 1U� units with optional electric coils). V\' OF -(UKW cvr Unit Size AA 1313 CC Filter Size 2, 3 21 12 12 (2) 12 72 x 10 4,5 26 V: 15 15 (2)15x12 6 26 72 17 15 (2) 17 '12x 12 Unit Size R• S' T 1 Row Coil 2 Row Coil X X 2, 3 19 12 '/2 1/4 2 3 4, 5 24 '/: 15 1 2 3 6 24 '/2 17 '/: 2 /4 2 3 Unit Size R• S• 2, 3 11 10 4, 5 16 13 6 20 15 Prfmary Alr I 22?'; :;2 ? ;. < 21i. 22 ? } % ?.; };. ; is ��� •t2; l e i(. ?-:...., % >�j` Submittal FP- PMFV -1.0 Accessories (Optional) Check ® if provided ❑ Hot water Coil Section All dimensions are in inches. Standard Features • '/:' copper tubes. • Aluminum ripple fins, 10 per inch. • Connections: Male solder, 1- row' /2 ", 2 -row W. Right hand only. ❑ Electric Coil Section All dimensions are in inches. Standard Features • Automatic reset thermal cutouts, one per element. • Single point electrical connection for entire unit, including coil. • Positive pressure air flow switch. • Flanged duct connection. • Coil is installed at discharge of unit. General Description 5 -1 5 • Heavy steel casing, with leak resistant construction. • Dual density insulation, coated to prevent air erosion, meets requirements of NFPA 90A and UL 181. • Bottom access panel can be removed for service. • Galvanized steel casing. • Flanged duct connection. • Coil is installed at induced air inlet. Note: Coil control box replaces stan- dard terminal unit control box. Options Check ® Selection ❑ Mercury contactors. ❑ Fuse block. ❑ Disconnect switch, door interlock type. ❑ Manual reset cutout. ❑ Oust tight construction. • Energy efficient fan motor, permanent split capacitor type, mounted in vibration isolators. • Adjustable SCR fan speed control, with minimum voltage stop. • Pressure independent primary air flow control. Coil Rows ❑ 1 -Row ❑ 2 -Row • Note: R and S are inside dimensions. B 1U. R— J 2 , 12 L.- 1 /2 Air s • Flow x Check ET if provided. ANEW Supply Voltage 0208 V, 1 ph, 60 Hz. 0240 V, 1 ph, 60 Hz. 0277 V, 1 ph, 60 Hz. 0208 V, 3 ph, 60 Hz. 0480 V, 3 ph, 60 Hz (4 wire wye). Check 0 Selection ' Note: R and S are inside dimensions. ❑ Induced Air Inlet Attenuator All dimensions are in inches. IMNIMMMINa • Multipoint inlet velocity sensor with center averaging. • Primary air flow balancing connections. • Single point electrical connections. • Rectangular discharge qq�" for flanged duct connectioN§. MAR 2 0 1998 T 1 T U s° Note: This submittal is meant to demonstrate general Cimerwons of this product. The drawing on this submittal are not meant to detail every Ep S aspect of the product wits mans= Drawings an not to scats. TITUS reserves the ngnt to make changes without written notice. 990 Security Row • Richardson, Texas 75081 •214699.1030 • Fax 214-644 -4953 PERMIT GEr1 As Noe nnrwoa rb pore a MN ..on refry a ,oaafco• a VWVIMMMI •, ay Mn w a.y mane warem a wmAIng l AIWA, vrraeMW a- Want* • W aM •.•a.wra. amp, .w.wo1 •iM.m woo.* DrMa•n n wiry ran Twins Y.eIMO• Mc Unit Size Inlet Size 1 A 1 B 1 C 1 D 1 E F iGitgliat J 1 K Xi= M N 2.6 Filter Size 1.1 6 3 '1. 6.4 I 2.7 5 'h i 5 1/2 6.4 1 2.7 2.0 5 '13 9,8 2, 3 8 11 10 2 '/: 2 7 5 '/i ! 3 14 6 7: 12 31 20 1 /: 39 ' /: 22 x 14 10 5 4, 5 10 16 13 2 : 2 8 : 7 4 , I 17 7 h 27 x 17 12 ,, 7'�� 8'/: 14 10 7 'A 7'h 6 12 20 15 2 '/, 2 9 '1: 7 '/' 5 '/, 19 8 '/' 17 34 '/, 25 '/, 1 '/, 51 27 x 19 14 9 1 /1 9 '/: 16 9 1 4 M dimensions are in inches. Fitter size is for unit without attenuator For filter sae rvrrn attenuator, please see reverse side. Unit Size Motor Horse- power Motor Amperage Ratings 120/1/60 12081240/1/601 277/1/60 FLA 1 FLA FLA 2 ' /,. 2.6 1.1 0.8 3 '1. 6.4 I 2.7 2.0 4 '/. 6.4 1 2.7 2.0 5 '13 9,8 j 4.0 3.0 6 3 /4 18.0 i 7.5 5.6 Dimensions are in inches TITUS® Submittal Terminal Units • Fan Powered • Parallel Type Model: AMFV • Pressure Independent • Analog Electronic Controls FLA a Full Load Amperage, as tested in accordance whit UL 1995. AU tan motors are single phase, same voltage as ele oil (when supplied), with exception that 277 voltage motors are used with s80 volt / 3 phase coil (4 wire wye). (Please see reverse side.) FP- AMFV -1.0 10 -1 -95 EBH A 1 1 1 G J I } C 26(Without Electric Coif) 18(With Electric Coll Control Enclosure t Filter (Optional) Access Panel (Entire Bottom Is, Removeable) N. EK fi M L Nominal Inlet Size Minus 1/8 Accessories (Optional) Check [f if provided. [f Induced air filter, 1' thick, disposable con- struction type. ❑ Fan Unit Fusing ❑ Fan disconnect switch (not available on units with optional electric coils). ❑ Micro-LocTM Insulation. ❑ Hanger Brackets. RECEIVED CITY OF TUK ti MAR 2 0 1998 PERMIT CENT00-9.0 -S Unit Size AA 88 CC Filter Sae 2, 3 21 12 12 (2) 12 '/: x 10 4, 5 26 '/: 15 15 (2) 15 x 12 6 26 '/: 17 15 (2) 17'/: x 12 Unit Size R• I S• I T 1 Row Coil 1 2 Row Coil X X 2, 3 1 19 112 '/2 I '/. 2 1 3 4, 5 1 24 1/21 15 1 1 2 1 3 6 1 241/2117 '12 i V. 2 I 3 Unit Size R• S 2, 3 11 10 4, 5 16 13 6 20 15 Submittal FP- AMFV -1.0 10 -1 -95 Accessories (Optional) Check ® if provided ❑ Hot Water Coil Section All dimensions are in inches. Standard Features • '/i copper tubes. • Aluminum ripple fins, 10 per inch. • Connections: Male solder, 1-row VI", 2-row ' /.. Right hand only. • Galvanized steel casing. • Flanged duct connection. • Coil is installed at induced air inlet. 1/2 O s� AFle./ « o Coil Rows Check g if provided. ❑ 1 -Row ❑ 2 -Row • Note: R and S are inside dimensions. ❑ Electric Coil Section All dimensions are in inches. Standard Features • Automatic reset thermal cutouts, one per element. • Single point electrical connection for entire unit, including coil. • Positive pressure air flow switch. • Flanged duct connection. • Coil is installed at discharge of unit. Note: Coil control box replaces standard ter- minal unit control box. Options Check 2 Selection ❑ Mercury contactors. ❑ Fuse block. ❑ Disconnect switch, door interlock type. ❑ Manual reset cutout. ❑ Dust tight construction. J 8 1 R VI: L Supply Voltage Check 21 Selection 0208 V, 1 ph, 60 Hz. 0240 V, 1 ph, 60 Hz. 0277 V, 1 ph, 60 Hz. 0208 V, 3 ph, 60 Hz. 0480 V, 3 ph, 60 Hz (4 wire wye). ' Note: R and S are inside dimensions. ❑ Induced Air Inlet Attenuator All dimensions are In inches. General Description • Heavy steel casing, with leak resistant construction. • Dual density insulation, coated to prevent air erosion, meets requirements of NFPA 90A and UL 181. • Bottom access panel can be removed for service. • Energy efficient fan motor, permanent split capacitor type, mounted in vibration isolators. TITUS® • Adjustable SCR fan speed control, with minimum voltage stop. • Pressure independent primary air flow control. • Electronic proportional room thermostat with adjustable temperature setpoint Is included with unit. • Minimum and maximum air flow adjustments are made at the room thermostat, using a digital voltmeter. • Single point electrical connections. • Rectangular discharge opening is designed for flanged duct connections. RECEIVED CITY OF TUKWIIA Nola: This subm'Ual is meant to duinanstrate general dimensions of this product. The drawing on dt s submittal are not meant to detail • ry AR $94 aspect o1 th• product with exoctnees. Drawmgs are not to scale. 1TNS reserves me right to make Menges mahout written notice. 990 Security Row • Richardson, Texas 75081 •214-699 -1030 • Fax 214-644-4953 PERMIT CENTER M Vie nwm.M w Dort el tor.• .on rr,•,. tr n refs• i or •on•t•.0 w •r.y lean w wq mum worsm.s or frowrns•l. smarm •e•r•t wm. •'• AMPOI4 r try fly ~WOO w•rq raw* moony •w+wn wworor•• w mot torn Imam Yreeetm. Yw. S: t tt`' is rr ' Submittal FP- AMFV -1.0 10 -1 -95 Accessories (Optional) Check ® if provided ❑ Hot Water Coil Section All dimensions are in inches. Standard Features • '/i copper tubes. • Aluminum ripple fins, 10 per inch. • Connections: Male solder, 1-row VI", 2-row ' /.. Right hand only. • Galvanized steel casing. • Flanged duct connection. • Coil is installed at induced air inlet. 1/2 O s� AFle./ « o Coil Rows Check g if provided. ❑ 1 -Row ❑ 2 -Row • Note: R and S are inside dimensions. ❑ Electric Coil Section All dimensions are in inches. Standard Features • Automatic reset thermal cutouts, one per element. • Single point electrical connection for entire unit, including coil. • Positive pressure air flow switch. • Flanged duct connection. • Coil is installed at discharge of unit. Note: Coil control box replaces standard ter- minal unit control box. Options Check 2 Selection ❑ Mercury contactors. ❑ Fuse block. ❑ Disconnect switch, door interlock type. ❑ Manual reset cutout. ❑ Dust tight construction. J 8 1 R VI: L Supply Voltage Check 21 Selection 0208 V, 1 ph, 60 Hz. 0240 V, 1 ph, 60 Hz. 0277 V, 1 ph, 60 Hz. 0208 V, 3 ph, 60 Hz. 0480 V, 3 ph, 60 Hz (4 wire wye). ' Note: R and S are inside dimensions. ❑ Induced Air Inlet Attenuator All dimensions are In inches. General Description • Heavy steel casing, with leak resistant construction. • Dual density insulation, coated to prevent air erosion, meets requirements of NFPA 90A and UL 181. • Bottom access panel can be removed for service. • Energy efficient fan motor, permanent split capacitor type, mounted in vibration isolators. TITUS® • Adjustable SCR fan speed control, with minimum voltage stop. • Pressure independent primary air flow control. • Electronic proportional room thermostat with adjustable temperature setpoint Is included with unit. • Minimum and maximum air flow adjustments are made at the room thermostat, using a digital voltmeter. • Single point electrical connections. • Rectangular discharge opening is designed for flanged duct connections. RECEIVED CITY OF TUKWIIA Nola: This subm'Ual is meant to duinanstrate general dimensions of this product. The drawing on dt s submittal are not meant to detail • ry AR $94 aspect o1 th• product with exoctnees. Drawmgs are not to scale. 1TNS reserves me right to make Menges mahout written notice. 990 Security Row • Richardson, Texas 75081 •214-699 -1030 • Fax 214-644-4953 PERMIT CENTER M Vie nwm.M w Dort el tor.• .on rr,•,. tr n refs• i or •on•t•.0 w •r.y lean w wq mum worsm.s or frowrns•l. smarm •e•r•t wm. •'• AMPOI4 r try fly ~WOO w•rq raw* moony •w+wn wworor•• w mot torn Imam Yreeetm. Yw. CIO sao TITUS® Models: PMFV, AMFV, DMFV ■ Fan Performance vs. Downstream Static Pressure ■ Induction Side 600 550 500 450 400 350 X 300 250 200 150 100 50 2000 1800 1600 1400 1200 1000 u 800 600 400 200 0 0.0 Static Pressure 0 Unit Size 2 J 0 t0 MAX MIN - Fan Powered Terminals > Performance Data 19.1 o . 5 `1'1O 800 750 700 650 600 u 550 500 450 400 350 300 0.1 0.2 0.3 0.4 05 06 00 02 03 04 05 06 • Inches Unit Size 5 of Water 8 2 . Iy Itp to MAX 0.0 0.1 0.2 0.3 0.4 0.5 0 6 Static Pressure - Inches of Water 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 No Coil or Electric Coil 1 Row Water Cod 2 Row Water Coil Unit Size 3 •I c1 \NN..s h L "'": MIN Stat.: •essure - Inches of Water Unit Size 6 . tG m tD - rn itt • MIN 1100 00 0.2 0.3 0.4 0.5 06 Stat c Pressure - Inches of Water 1400 1300 1200 1100 1000 Y. 900 800 700 600 500 400 Unit Size 4 3 0 1 cp 00 01 02 03 04 05 06 Static Pressure - Inches of Water RECENED CITY OP TUKWILA MAR 2 0 1998 PERMIT CENTER 6 16 1600 • - 20 23 30 34 38 41 2000 • 20 24 27 33 37 42 44 2600 20 25 29 32 37 41 45 47 3200 24 28 33 35 40 44 48 50 4000 28 32 37 39 43 47 51 53 4 -5 -6 14 1200 • - • 20 27 31 35 37 1600 • - 23 25 30 35 39 41. 2000 • 22 27 29 33 37 42 44 2400 22 26 30 32 36 40 44 46 3000 25 30 34 36 39 43 47 49 4-5-6 12 900 - • • • 23 27 31 33 1100 • - 20 22 25 29 33 36 1400 • 20 24 26 29 33 37 39 1800 20 24 28 31 32 36 40 42 2000 22 26 30 33 33 , 37 41 43 2 -3 4.5 6 10 600 - • • • - 21 25 27 800 • - • 20 21 25 29 31 1000 • - 22 24 24 28 32 34 1200 • 21 25 28 27 31 34 37 1400 20 24 28 30 29 33 37 39 2-3 4-5 8 350 - • • • - 7 • 21 400 • - • 1 1 P • 20 23 500 • - • - - • 23 26 700 - 21 21 23 20 24 28 30 800 • • 23 26 22 26 30 32 • 2-3 8 225 Unit Size • cfm 5 - 7 Environ. Effect - 300 • - - 1 1 P 9 - 20 400 • - • - 11 21 24 450 - 21 - 21 • • 23 25 500 • • 21 23 14 20 24 27 Sound Noise Criteria (NC) Radiated Attenuation Values Octave Bands Unit Size Inlet Size cfm 5 Discharge 7 Environ. Effect Radiated 2 1 1 Ps 1 1 1 P 9 0.5" 11.0" 1 2.0" 1 3.0" 0.5" 1.0" 1 2.0" 1 3.0" E a a 542 TITUS® Fan Pork Terminals > Performance Data �o 1 �,� 1')')(, Models: PMFV, AMFV, DMFV ■ Application Data ■ NC Values 100% Primary Air > - P is the difference in static pressure from inlet to discharge. > Dash ( -) in space denotes NC value less than 20. > All sound data are based upon tests conducted in accordance with ARI 880.94. Application data are based upon factors found in ARI Standard 885.90: > Ceiling type • mineral fiber. 5/8 in.•35 lb./ cu. ft. > Room size - 3.000 cu. ft.. 10 ft. from the source Acoiication data are based upon factors found In ARI Standard 885-90: > End reflection • 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 in. thick duct lining > Room size • 3.000 cu. ft.. 10 It. from the source > For complete information on calculation of NC levels, refer to catalog pages C65 -C77. The following dB credits per octave band have been used in the calculations of NC values shown above. for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction (dBI 0 3 6 8 10 11 RECEIVED cm/ TUKV4ii-r` MA'R 2, Q 199 PERMIT CENTER Radiated Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 Ceiling Effect 9 10 12 14 15 15 Room Effect 9 10 11 12 13 14 Total dB reduction 21 22 24 27 29 30 E a a 542 TITUS® Fan Pork Terminals > Performance Data �o 1 �,� 1')')(, Models: PMFV, AMFV, DMFV ■ Application Data ■ NC Values 100% Primary Air > - P is the difference in static pressure from inlet to discharge. > Dash ( -) in space denotes NC value less than 20. > All sound data are based upon tests conducted in accordance with ARI 880.94. Application data are based upon factors found in ARI Standard 885.90: > Ceiling type • mineral fiber. 5/8 in.•35 lb./ cu. ft. > Room size - 3.000 cu. ft.. 10 ft. from the source Acoiication data are based upon factors found In ARI Standard 885-90: > End reflection • 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 in. thick duct lining > Room size • 3.000 cu. ft.. 10 It. from the source > For complete information on calculation of NC levels, refer to catalog pages C65 -C77. The following dB credits per octave band have been used in the calculations of NC values shown above. for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction (dBI 0 3 6 8 10 11 RECEIVED cm/ TUKV4ii-r` MA'R 2, Q 199 PERMIT CENTER Discharge Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 End Reflection 11 6 2 0 0 0 Duct Lining 1 3 8 21 20 12 5'. 8" Flex Duct 6 10 17 19 19 12 Room Effect 9 10 11 12 13 14 Total dB reduction 30 31 39 53 53 39 E a a 542 TITUS® Fan Pork Terminals > Performance Data �o 1 �,� 1')')(, Models: PMFV, AMFV, DMFV ■ Application Data ■ NC Values 100% Primary Air > - P is the difference in static pressure from inlet to discharge. > Dash ( -) in space denotes NC value less than 20. > All sound data are based upon tests conducted in accordance with ARI 880.94. Application data are based upon factors found in ARI Standard 885.90: > Ceiling type • mineral fiber. 5/8 in.•35 lb./ cu. ft. > Room size - 3.000 cu. ft.. 10 ft. from the source Acoiication data are based upon factors found In ARI Standard 885-90: > End reflection • 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 in. thick duct lining > Room size • 3.000 cu. ft.. 10 It. from the source > For complete information on calculation of NC levels, refer to catalog pages C65 -C77. The following dB credits per octave band have been used in the calculations of NC values shown above. for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction (dBI 0 3 6 8 10 11 RECEIVED cm/ TUKV4ii-r` MA'R 2, Q 199 PERMIT CENTER 6 1250 34 - 1350 35 - 1500 36 - 1650 37 - 1800 39 - 2100 41 21 3 800 30 - 900 32 - 5 1100 35 550 30 1300 37 • • 1500 39 - 12 1800 42 21 3 475 28 - 500 29 - 525 29 - 550 30 - 600 31 • 650 32 - 4 600 31 - 700 32 - 800 33 - 900 33 - 1000 34 - 1150 35 - 2 300 28 - 350 30 - 400 31 - 450 32 - 500 33 - 520 33 10 TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data e 0 T 9NG o 1 996 Application data are based upon factors found in ARI Standard 885-90: • Ceiling type • mineral fiber. 518 in. -35 Ill/ cu. ft. > Room size • 3.000 cu. ft.. 10 ft. from the source Application oata are based upon factors found in ARI Standard 885 -90: • > End reflection • 8 in. termination • Flex type - vinyl core flex >- 5 ft. of 1 in. thick duct lining > Room size - 3.000 cu. ft.. 10 ft. from the source The following dB credits per octave band have been used ;n the calculations of NC values shown above. for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels. refer to catalog pages C65-C77. RECEIVED__ ILA CITY OF M AR 2 0 i998 PERMIT carrell S43 Fan NC Levels Size cfm Rad. Disc. 6 7. NC NC TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data e 0 T 9NG o 1 996 Application data are based upon factors found in ARI Standard 885-90: • Ceiling type • mineral fiber. 518 in. -35 Ill/ cu. ft. > Room size • 3.000 cu. ft.. 10 ft. from the source Application oata are based upon factors found in ARI Standard 885 -90: • > End reflection • 8 in. termination • Flex type - vinyl core flex >- 5 ft. of 1 in. thick duct lining > Room size - 3.000 cu. ft.. 10 ft. from the source The following dB credits per octave band have been used ;n the calculations of NC values shown above. for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels. refer to catalog pages C65-C77. RECEIVED__ ILA CITY OF M AR 2 0 i998 PERMIT carrell S43 Radiated Attenuation Values Octave Bands 2 3 4 5 6 7. Environ. Effect 3 2 1 1 1 1 Ceiling Effect 9 10 12 14 15 15 Room Effect 9 10 11 12 13 14 Total dB reduction 21 22 24 27 29 30 TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data e 0 T 9NG o 1 996 Application data are based upon factors found in ARI Standard 885-90: • Ceiling type • mineral fiber. 518 in. -35 Ill/ cu. ft. > Room size • 3.000 cu. ft.. 10 ft. from the source Application oata are based upon factors found in ARI Standard 885 -90: • > End reflection • 8 in. termination • Flex type - vinyl core flex >- 5 ft. of 1 in. thick duct lining > Room size - 3.000 cu. ft.. 10 ft. from the source The following dB credits per octave band have been used ;n the calculations of NC values shown above. for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels. refer to catalog pages C65-C77. RECEIVED__ ILA CITY OF M AR 2 0 i998 PERMIT carrell S43 Discharge Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 End Reflection 11 6 2 0 0 0 Duct Lining 1 3 8 21 20 12 5 '. 8" Flex Duct 6 10 17 19 19 12 Room Effect 9 10 11 12 13 14 Total dB reduction 30 31 39 53 53 39 TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data e 0 T 9NG o 1 996 Application data are based upon factors found in ARI Standard 885-90: • Ceiling type • mineral fiber. 518 in. -35 Ill/ cu. ft. > Room size • 3.000 cu. ft.. 10 ft. from the source Application oata are based upon factors found in ARI Standard 885 -90: • > End reflection • 8 in. termination • Flex type - vinyl core flex >- 5 ft. of 1 in. thick duct lining > Room size - 3.000 cu. ft.. 10 ft. from the source The following dB credits per octave band have been used ;n the calculations of NC values shown above. for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels. refer to catalog pages C65-C77. RECEIVED__ ILA CITY OF M AR 2 0 i998 PERMIT carrell S43 2 -3 4-5 6 10 600 0.038 59 62 64 66 67 53 56 59 61 62 46 49 51 53 55 40 43 45 47 49 32 35 37 39 40 28 31 32 34 35 62 65 67 69 71 56 59 62 64 66 49 52 55 57 58 43 46 48 50 52 35 38 40 42 43 31 33 35 36 38 65 68 70 72 74 59 63 65 67 69 52 55 58 60 62 46 49 51 53 55 38 41 43 45 46 33 36 37 39 40 67 70 72 74 76 61 64 67 69 71 54 57 60 62 64 48 51 53 55 57 40 43 45 47 48 35 37 39 40 42 800 0.068 1000 0.107 1200 0.154 1400 0.209 6 16 1600 0.029 67 70 73 75 77 64 66 69 72 74 53 56 59 61 64 46 48 51 53 56 41 43 45 47 49 37 39 41 43 44 71 73 76 78 80 67 70 73 75 78 57 59 62 65 67 49 51 54 56 59 44 46 48 50 52 39 41 43 45 47 74 76 79 81 84 71 73 76 79 31 60 63 66 68 70 52 54 57 59 62 47 49 51 53 55 42 44 46 48 49 76 78 81 83 86 73 75 78 81 83 62 65 67 70 72 54 56 59 61 64 49 51 53 55 57 43 45 47 49 51 2000 0.045 2600 0.076 3200 0.115 4000 0.180 2-3 4 -5 8 350 0.040 54 55 58 61 63 46 48 50 54 56 41 42 45 49 50 36 38 40 44 45 27 28 30 34 35 23 25 26 29 30 57 58 61 64 66 50 51 54 57 59 44 46 48 52 53 39 41 43 47 48 30 31 34 37 38 26 27 29 32 33 60 61 64 68 69 53 55 57 61 62 47 49 51 55 57 43 44 46 50 51 33 35 37 40 41 28 30 31 34 36 62 63 66 69 71 55 57 59 63 64 49 51 53 57 59 44 46 48 52 53 35 37 39 42 43 30 31 33 36 37 400 0.052 500 0.081 700 0.158 800 0.207 4 -5 6 14 1200 0.029 64 68 70 72 74 61 64 66 68 71 51 54 57 59 61 45 48 51 52 55 38 41 43 44 46 34 37 39 40 42 68 71 73 75 78 64 67 70 72 74 54 58 60 62 65 48 51 53 55 57 41 44 46 48 50 37 39 41 43 45 71 74 77 79 81 68 71 73 75 78 58 61 63 65 68 50 53 56 57 60 45 47 49 51 53 39 42 44 45 47 73 76 79 81 83 70 73 75 77 80 60 63 65 67 70 52 55 57 59 61 47 49 51 53 55 41 43 45 47 49 1600 0.052 2000 0.081 2400 0.117 3000 0.183 4-5 6 12 900 0.035 62 64 67 69 70 57 60 62 65 66 49 51 54 57 58 43 45 47 50 51 36 37 40 42 43 32 33 35 38 38 65 67 70 73 74 61 63 66 68 69 52 54 57 60 61 46 48 50 53 54 39 41 43 45 46 34 36 38 40 41 69 71 73 76 77 64 36 69 72 73 55 58 60 63 64 49 51 53 56 57 42 44 46 48 49 37 38 40 43 43 71 73 75 78 79 66 68 71 74 75 57 60 62 65 66 51 53 55 58 59 44 46 48 50 51 38 40 42 44 45 1100 0.053 1400 0.085 1800 0.141 2000 0.174 2 -3 6 225 0.064 49 52 56 57 58 41 44 47 49 50 38 41 45 46 47 35 38 41 42 43 23 26 29 30 31 19 22 24 25 26 53 56 59 60 61 44 48 51 52 53 41 45 48 49 50 38 41 44 45 46 26 29 32 33 34 22 24 27 28 29 56 59 62 64 65 48 51 54 56 57 44 48 51 52 53 41 44 47 48 49 30 32 35 36 37 24 27 29 31 31 58 61 64 66 67 50 53 56 58 59 46 50 53 54 55' 42 45 49 50 51 32 34 37 38 39 26 28 31 32 33 300 0.114 400 0.202 450 0.256 500 0.316 Inlet Size Prl. cfm Min. A P Sound Power @ 1.5" .1 P 2 3 4 5 6 7 6 400 0.200 61 59 50 46 34 28 8 700 0.160 66 66 54 49 39 33 10 1100 0.130 70 72 58 51 43 37 12 1600 0.140 73 77 60 54 46 41 14 2100 0.120 76 80 63 55 48 43 16 2800 0.200 79 85 65 57 51 45 Unit Inlet Min. Primary Air • Sound Power Octave Bands Size Size cfm A P 0.5 ".4 P 1.0 "4 Ps 2.0 " a Ps 3.0 ".3 Ps 2 314 51617 2131451617 213 4151617 2 31415 617 S44 TITUS® Models: PMFV, AMFV, DMFV • Radiated Sound Power Levels ■ 100% Primary Air ARI Certification Rating Points Fan Powered Terminals > Performance Oala 1946 *4 ,5.3 1996 A Participating Corporation in the ARI 880 Certification Program > Min. P is the lowest static pressure difference idamper wide open). > Radiated sound power is the noise Transmitted through the casing walls. > Sound power levels are in decibels. re 10 watts All sound data are based upon tests conducted in accordance with ARI 880.94. Note: Ratings in accordance with ARI Standard 880-94 and certified to ARI. RECEIVED CITY of TUKW11.0` MAR 2 0 1999 pERMIT CENTER 6 1 6 1600 0.029 69 , 58 65 ' 5' 60 • 55 2 2 - 54 63 1 58 76 75 74 67 66 60 78 77 76 69 1 68 62 2000 0.345 "2 1 7 1 " 5 52 57 "6 .. - 4 5. _5 ; 60 79 1 79 77 70 68 1 63 81 81 79 1 72 70 1 65 2600 0.076 76 1 7 5 73 55 55 . 6C :C 7 0 "" "' 1 68 163 831 83 81 74 71 1 66 85 85 82 1 76 73 1 68 3200 0.115 79 1 79 77 1 57 1 63 53 52 3: - 4 . "3 1 66 86 186 83 77 73 69 88 88 85 79 75 1 70 4000 0.180 83 1 8 2 1 "9 17 1 69 1 65 55 55 .2 "" : "2 1 68 89 1 89 86 80 1 75 1 7 1 91 1 91 1 88 1 82 77 73 4.5 6 14 1200 0.029 66165 63 58 1 5 6 1 51 6 9 1 6 8 1 . 3 7 1 5 1 1 6 0 54 73 72 70 64 63 57 75 74 72 66 65 58 1600 0.052 70 69 6 7 1 6 2 1 5 9 1 5 5 731 7317 165162 51' 77 76 74 68 66 60 79 78 76 70 68 62 2000 0.081 73 73 70 65 1 61 57 76 1 76 1 73 1 88 1 65 60 80 80 77 71 68 63 82 82 79 73 70 64 2400 0.117 75 75 72 68 1 63 59 79 1 79 1 "6 71167 62 82 82 79 74 70 65 84 84 81 76 72 66 3000 0.183 78 79 751 71 166162 821821791 74169165 85 86 82 77 72 67 87 88 84 79 74 69 2-3 4-5 6 10 600 0.038 57 57 53 49 1 47 41 60 60 i 5 1 53 50 44 63 64 60 57 53 47 65 66 62 59 55 49 800 0.068 61 61 57 54 50 44 64 65 61 1 57 53 47 67 68 64 61 56 50 69 70 66 63 58 52 1000 0.107 64 64 60 57 152 47 67 1 68 ; 3. 1 60 1 55 50 71 72 67 64 58 53 72 74 69 66 60 55 1200 0.154 67 67 63 59154 49 70171 166153157 52 73 74 70 67 60 55 75 76 72 69 62 57 1400_0.209 69 70 65 62 155 51 721 73163 1 551 59 54 75 77 72 69 62 57 77 79 74 71 64 59 2 -3 6 225 0.064 43 45 40 39 34 28 47 49143143 37 31 51 53 46 46 40 33 53 55 48 48 42 35 300 0.114 47 50 44 44 37 31 51 53147147 40 34 55 57 50 50 43 37 57 59 52 52 45 38 400 0.202 51 54 48 48 40 35 55 58151 51 43 37 59 61 54 55 46 40 61 63 56 57 48 42 450 0.256 53 56 49 49 41 36 57 59152153 44 39 60 63 56 56 47 41 62 65 58 58 49 43 500 0.316 55 57 51 511 37 58 61154154 45 40 62 64 57 58 48 43 64 67 59 60 50 44 4-5 6 1 2 900 0.035 62 1 51 59 1 _5 :2 - 55 55 52 55 __ 1 50 69 69 66 61 58 53 71 71 68 63 50 54 1100 3.053 65 1 64 51 __ 5 9 53 ._ 55 : • 5 1 52 72 1 72 69 64 60 1 55 74 1 74 71 1 66 162 63 68 1 57 1400 0.085 58 1 68 55 1 5 . _ _ 52 72 2 5 _ 5.4 50 1 55 75 1 75 72 67 63 1 58 77 1 77 74 1 69 1 65 1 59 1800 0.141 72 1 72 1 68' 55 5 ' 55 -.. - 5 2 is ' 63 1 58 79 1 79 75 71 66 1 61 81 1 81 77 1 73 1 68 62 2000 0 174 73 1 73 1 69 1 : _ :C 56 "" "" " 3 _ 3 1 5.3 1 5 9 80 1 8 1 77 7 2 1 6 7 1 62 82 1 83 79 1 7 69 64 2.3 4 -5 8 350 0.040 49 50 45 114 1 40 i 31 53 1 54 .- 47 33 37 56 57 52 51 46 1 40 58 59 55 52 48 42 400 0.052 51 52 47 46 14' 1 36 55 1 56 5' 191 41139 58 59 54 52 47 42 60 61 56 54 49 43 500 0.081 54 56 50119144138 58:59 62 ; 64 54 52147 55 57 1 50 1 1 45 61 66 63 68 57 62 56 60 50 54 44 48 63 68 65 70 59 64 58 62 52 55 46 50 700 0.158 59 1 6 1 1 55 1 54 : 47 1 42 800 0.207 61 1 63 1 57 1 56 • 49 111 63 1 58 : _ 59 i 52 47 68 70 64 1 62 1 55 1 50 70 72 66 64 57 51 Inlet Size PrI. cfm Min. JPs Sound Power @ 1.5' A P: 2 1 3 1 4 1 5 1 6 1 7 6 400 0.200 57 1 67 1 58 . 53 15 39 8 700 0.160 61 1 74 66 1 59 52 - 10 1100 0.130 7' 130 73 58 53 12 1600 0.'40 7 6 85 "- 53. :- 58 1 4 2100 0.120 79 1 38 133 ' "' 3" 5" 16 2800 0 200 33 i 92 1 38 ' 4 -: 58 Unit Size Inlet Size cfm Min. .. Ps Primary Air • Sound Power Octave Bands 0.5 "A Ps 1.0 " Ps 2.0 ".. P 3.0 "4 Ps 2 3 1 4 1 5 1 6 1 7 213 1 5 7 21314 6 7 2131 7 TITUS® Fan Powered Terminals > Performance Data t�4s 53 199(3 Models: PMFV, AMFV, DMFV • Discharge Sound Power Levels • 100% Primary Air ARI Certification Rating Points > Min.. P; is the lowest static cressure cr'e•e ":e ca °ce• :rc_ > Discharge sound oower s ire nose eT ;1ee ' : ^a _ .: s: - s• :: ._ 1 downstream duct. > Sound power 'eves are n cec:dels. •e • :fans All sound data are oases Jocn tests :.,rc -c:ec ^ ac::rca ^ce .. •- 12 1 53■.94 Note: Ratings in accordance with ARI Standard SSC -9- arc certified to ARI. A Participating Corporation In the ARI 880 Certification Program CITY OFETUKWIIA MAR 2 0 1998 PERMIT CENTER S45 2 300 0.25 63 57 58 50 43 39 52 54 52 51 42 33 350 0.25 64 58 59 51 45 41 54 55 53 52 43 35 400 0.25 65 59 60 52 47 42 55 56 54 53 44 37 450 0.25 66 60 61 53 48 44 56 57 55 54 45 38 500 0.25 67 60 62 54 50 45 57 58 56 54 46 40 520 0.25 67 61 63 55 50 46 58 59 57 54 47 40 3 475 0.25 66 62 58 50 45 41 60 63 58 54 52 44 500 0.25 66 62 58 51 46 42 61 63 59 55 53 45 525 0.25 67 63 59 51 46 43 62 64 60 56 53 46 550 0.25 67 63 59 52 47 44 63 64 60 56 54 47 600 0.25 67 64 60 53 48 46 64 65 62 57 56 48 650 0.25 68 64 61 54 50 48 65 66 63 58 57 50 4 600 0.25 66 64 61 53 50 45 60 55 57 51 47 41 700 0.25 67 64 61 54 52 48 61 56 58 53 49 43 800 0.25 67 64 62 55 54 50 62 57 59 55 51 45 900 0.25 68 64 62 56 55 52 63 58 60 56 52 47 1000 0.25 68 65 63 57 57 53 64 59 60 57 53 49 1150 0.25 69 65 64 58 59 55 65 60 61 58 55 51 5 800 0.25 66 61 60 54 51 46 61 56 57 53 48 41 900 0.25 67 62 61 55 53 48 63 58 1 60 55 51 44 1100 0.25 69 65 64 58 56 52 66 62 63 59 55 49 1300 0.25 71 67 66 60 59 56 69 65 66 62 59 53 1500 0.25 72 69 68 62 61 58 71 68 69 65 62 56 1800 0.25 74 71 70 64 64 62 74 71 72 68 66 60 6 1250 0.25 68 66 63 58 57 52 66 64 64 60 59 52 1350 0.25 69 67 64 59 58 54 68 65 65 61 60 53 1500 0.25 70 68 65 60 59 56 69 66 67 63 61 55 1650 0.25 71 69 66 61 61 58 71 68 69 65 63 57 1800 0.25 72 70 67 62 62 59 72 69 70 66 64 59 2100 0.25 74 71 69 63 64 62 74 72 73 69 67 62 Unit Size Fan cfm Outlet AP Unit Size Radiated Sound Power Fan cfm Fan Only Discharge Sound Power 2 3 Octave Bands 5 6 7 Octave Bands 2 1 3 1 4 5 1 6 7 2 3 14 15 6 7 CCI • S46 TITUS® Models: PMFV, AMFV, DMFV • Sound Power Levels • Fan Only • Heating Cycle ARI Certification Rating Points Fan Powered Terminals > Performance Data 1946 g,57.1 1996 > Outlet AP 5 is the difference in static pressure from the terminal discharge to the room. > Radiated sound power is the noise transmitted through the casing walls. AO°e-cuK > Discharge sound power is the noise emitted from the unit discharge into the downstream det'l"( > Sound power levels are in decibels, re 10'' watts. ^ 'Z o 199 > All sound data are based upon tests conducted in accordance with ARI 880-94. VIP A Participating Note: Ratings in accordance with ARI Standard 880-94 and certified to ARI. •' 'Corporation PE NM� 1 in the ARI 1380 Certification Program Radiated Sound Power Discharge Sound Power Unit Size Fan watts Fan cfm Fan Only Fan Only 2 3 4 5 6 7 2 3 4 5 6 7 2 175 400 70 64 66 58 53 49 61 62 60 57 52 49 3 375 680 73 69 68 61 57 57 73 73 70 65 65 62 4 450 950 72 68 67 62 62 59 68 64 65 62 59 55 5 900 1380 77 74 75 71 69 63 77 74 75 71 69 63 6 1000 1610 77 74 72 66 67 65 77 75 76 72 70 65 CCI • S46 TITUS® Models: PMFV, AMFV, DMFV • Sound Power Levels • Fan Only • Heating Cycle ARI Certification Rating Points Fan Powered Terminals > Performance Data 1946 g,57.1 1996 > Outlet AP 5 is the difference in static pressure from the terminal discharge to the room. > Radiated sound power is the noise transmitted through the casing walls. AO°e-cuK > Discharge sound power is the noise emitted from the unit discharge into the downstream det'l"( > Sound power levels are in decibels, re 10'' watts. ^ 'Z o 199 > All sound data are based upon tests conducted in accordance with ARI 880-94. VIP A Participating Note: Ratings in accordance with ARI Standard 880-94 and certified to ARI. •' 'Corporation PE NM� 1 in the ARI 1380 Certification Program Trane Air Conditioning Economics By: Comfort Plus c *************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ***** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** ** ** ** ** TRACE 600 ANALYSIS by Comfort Plus ****** **************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** **************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CORPORATE SQUARE BLDG 6 TUKWILA, WA LOAD DESIGN - 1 Weather File Code: SEATTLE Location: SEATTLE, WA Latitude: 47.0 (deg) Longitude: 122.0 (deg) Time Zone: 8 Elevation: 386 (ft) Barometric Pressure: 29.5 (in. Hg) Summer Clearness Number: 0.95 Winter Clearness Number: 0.95 Summer Design Dry Bulb: 82 (F) Summer Design Wet Bulb: 66 (F) Winter Design Dry Bulb: 24 (F) Summer Ground Relectance: 0.20 Winter Ground Relectance: 0.20 Air Density: Air Specific Heat: Density - Specific Heat Prod: Latent Heat Factor: Enthalpy Factor: 0.0749 (Lbm /cuft) 0.2444 (Btu /1bm /F) 1.0988 (Btu- min. /hr /cuft /F) 4,836.9 (Btu- min. /hr /cuft) 4.4953 (Lb- min. /hr /cuft) Design Simulation Period: June To November System Simulation Period: January To December Cooling Load Methodology: TETD /Time Averaging Time /Date Program was Run: 22 :30:24 2/26/98 Dataset Name: CORP6 .EZT ** ** ** ** ** Mg?) 005 V 600 PAGE 1 RECEIVED CITY OF TUKWILA MAR, 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus AIRFLOW - ALTERNATIVE 1 SYSTEM SUMMARY (Design Airflow Quantities) Main Auxil, Room Outside Cooling Heating Return Exhaust Supply Exhaust System System Airflow Airflow Airflow Airflow Airflow Airflow Airflow Number Type (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) 1 VTCV 3,776 22,152 22,152 22,152 3,776 0 0 Totals 3,776 22,152 22,152 22,152 3,776 0 0 CAPACITY - ALTERNATIVE 1 V 600 PAGE 2 SYSTEM SUMMARY (Design Capacity Quantities) Cooling Heating Main Sys. Aux. Sys. Opt. Vent Cooling Main Sys. Aux. Sys. Preheat Reheat Humidif. Opt. Vent Heating System System Capacity Capacity Capacity Totals Capacity Capacity Capacity Capacity Capacity Capacity Totals Number Type (Tons) (Tons) (Tons) (Tons) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) 1 VTCV 44.4 0.0 0.0 44.4 - 443,123 0 0 0 0 0 - 443,123 Totals 44.4 0.0 0.0 44.4 - 443,123 0 0 0 0 0 - 443,123 The building peaked at hour 14 month 8 with a capacity of 36.4 tons ENGINEERING CHECKS - ALTERNATIVE 1 ENGINEERING CHECKS Percent Cooling - -- Heating - - -- System Main/ System Outside Cfm/ Cfm/ Sq Ft Btuh/ Cfm/ Btuh/ Floor Area Number Auxiliary Type Air Sq Ft Ton /Ton Sq Ft Sq Ft Sq Ft Sq Ft 1 Main VTCV 17.05 1.17 498.7 425.0 28.23 1.17 -23.47 18,880 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus SYSTEM CHECKSUMS * * * * * * * * * * * * * * * * * * * * * * * ** COOLING COIL PEAK * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CLG SPACE PEAK * * * * * * * * * * ** HEATING COIL PEAK * * * * * * ** Peaked at Time =_> Mo /Hr: 8/14 * Mo /Hr: 9/11 * Mo /Hr: 13/ 1 Outside Air =_> OADB /WB /HR: 78/ 64/ 70.0 * OADB: 69 * OADB: 24 * * Space Ret. Air Ret. Air Net Percnt * Space Percnt * Space Peak Coil Peak Percnt Sens. +Lat. Sensible Latent Total Of Tot * Sensible Of Tot * Space Sens Tot Sens Of Tot Envelope Loads (Btuh) (Btuh) (Btuh) (Btuh) ( %) * (Btuh) ( %) * (Btuh) (Btuh) ( %) Skylite Solr 0 0 0 0.00 * 0 0.00 * 0 0 0.00 Skylite Cond 0 0 0 0.00 * 0 0.00 * 0 0 0.00 Roof Cond 0 4,933 4,933 0.93 * 0 0.00 * 0 - 12,307 2.78 Glass Solar 242,832 0 242,832 45.56 * 262,656 56.79 * 0 0 0.00 Glass Cond -465 0 -465 -0.09 * - 11,308 -2.45 * -71,872 - 71,872 16.22 Wall Cond 548 170 718 0.13 * 287 0.06 * - 10,602 - 14,732 3.32 Partition 0 0 0.00 * 0 0.00 * 0 0 0.00 Exposed Floor 0 0 0.00 * 0 0.00 * 0 0 0.00 Infiltration 0 0 0.00 * 0 -0.00 * -1 -1 0.00 Sub Tota1= => 242,915 5,102 248,017 46.53 * 251,634 54.41 * -82,475 - 98,912 22.32 Internal Loads * * Lights 96,656 0 96,656 18.13 * 96,656 20.90 * 0 0 0.00 People 96,288 96,288 18.06 * 48,144 10.41 * 0 0 0.00 Misc 64,437 0 0 64,437 12.09 * 64,437 13.93 * 0 0 0.00 Sub Total= => 257,382 0 0 257,382 48.29 * 209,238 45.24 * 0 0 0.00 Ceiling Load 1,005 -1,005 0 0.00 * 1,604 0.35 * -3,243 0 0.00 Outside Air 0 0 0 28,319 5.31 * 0 0.00 * 0 - 182,563 41.20 Sup. Fan Heat 0 0.00 * 0.00 * 0 0.00 Ret. Fan Heat 0 0 0.00 * 0.00 * 0 0.00 Duct Heat Pkup 0 0 0.00 * 0.00 * 0 0.00 OV /UNDR Sizing 0 0 0.00 * 0 0.00 * - 163,898 -163,898 36.99 Exhaust Heat -697 0 -697 -0.13 * 0.00 * 2,249 -0.51 Terminal Bypass 0 0 0 0.00 * 0.00 * 0 0.00 * * Grand Total = => 501,302 3,400 0 533,020 100.00 * 462,476 100.00 * - 249,615 - 443,123 100.00 Total Capacity Sens Cap. Coil Airfl Entering DB /WB /HR (Tons) (Mbh) (Mbh) (cfm) Deg F Deg F Grains 44.4 533.0 466.5 22,152 75.5 61.7 61.1 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Main Clg Aux Clg Opt Vent Totals 44.4 533.0 System 1 Peak VTCV COOLING COIL SELECTION HEATING COIL SELECTION Capacity Coil Airfl Ent Lvg (Mbh) (cfm) Deg F Deg F Main Htg -443.1 22,152 60.1 78.3 Infil Aux Htg 0.0 0 0.0 0.0 Supply Preheat -0.0 22,152 60.1 56.0 Mincfm Reheat 0.0 0 0.0 0.0 Return Humidif 0.0 0 0.0 0.0 Exhaust Opt Vent 0.0 0 0.0 0.0 Rm Exh Total -443.1 Auxil - VARIABLE TEMP CONSTANT VOL AIRFLOWS (cfm) Type Cooling Heating Vent 3,776 3,776 0 0 22,152 22,152 0 0 22,152 22,152 3,776 3,776 0 0 0 0 Leaving DB /WB /HR Deg F Deg F Grains 56.0 53.3 57.3 0.0 0.0 0.0 0.0 0.0 0.0 - - ENGINEERING CHECKS- - Clg % OA 17.0 Clg Cfm /Sqft 1.17 Clg Cfm /Ton 498.71 Clg Sqft/Ton 425.05 Clg Btuh /Sqft 28.23 No. People 189 Htg % OA 17.0 Htg Cfm /SqFt 1.17 Htg Btuh /SqFt -23.47 AREAS V 600 PAGE Gross Total Glass (sf) ( %) Floor 18,880 Part 0 ExFlr 0 Roof 9,440 Wall 9,504 0 0 2,784 29 -- TEMPERATURES (F) - -- Type Clg Htg SADB 56.0 78.3 Plenur 75.2 67.5 Return 75.2 67.5 Ret /OA 75.5 60.1 Runarnd 75.0 68.0 Fn MtrTD 0.0 0.0 Fn B1dTD 0.0 0.0 Fn Frict 0.0 0.0 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM COOLING - ALTERNATIVE 1 PEAK COOLING LOADS (Main System) V 600 PAGE 4 Space Coil Peak OA Rm Supp. Space Space Space Peak OA Rm Supp. Coil Coil Coil Time Cond. Dry Dry Air Sens. Lat. Time Cond. Dry Dry Air Sens. Lat. Room Mo /Hr DB /WB Blb Bulb Flow Load Load Mo /Hr DB /WB Blb Bulb Flow Load Load Number Description (F) (F) (F) (Cfm) (Btuh) (Btuh) (F) (F) (F) (Cfm) (Btuh) (Btuh) 1 7/17 78 61 75 56,0 806 16,827 979 7/17 78 61 75 56.0 806 17,073 772 2 10/12 63 54 75 56.0 3,809 79,524 3,917 9/13 74 61 75 56.8 3,809 75,814 4,574 3 7/ 9 67 57 75 56.0 2,017 42,114 1,958 8/ 9 67 59 75 56.1 2,017 40,363 2,287 4 6/19 69 55 75 56.0 1,153 24,075 2,938 7/14 79 65 75 56.5 1,153 24,498 4,545 5 7/15 80 64 75 56.0 2,448 51,102 11,669 7/14 79 65 75 56.1 2,448 54,969 18,053 6 lobby -1 7/17 78 61 75 56.0 843 17,607 2,611 7/16 79 63 75 56.5 843 18,046 3,049 Zone 1 Total /Ave. 69 60 75 56.0 11,076 231,249 24,072 78 64 75 56.4 11,076 230,764 33,281 Zone 1 Block 9/11 69 60 75 60.1 11,076 181,430 24,072 8/14 78 64 75 60.7 11,076 179,005 37,243 7 7/17 78 61 75 56.0 806 16,827 979 7/17 78 61 75 56.0 806 17,516 772 8 10/13 64 55 75 56.0 3,808 79,502 3,917 9/13 74 61 75 56.7 3,808 75,816 4,574 9 7/ 9 67 57 75 56.0 2,017 42,114 1,958 8/ 9 67 59 75 56.1 2,017 40,198 2,287 10 6/19 69 55 75 56.0 1,153 24,075 2,938 7/14 79 65 75 56.5 1,153 25,225 4,545 11 7/19 74 58 75 56.0 2,448 51,102 11,669 7/14 79 65 75 56.1 2,448 57,857 18,053 12 lobby -2 7/17 78 61 75 56.0 843 17,607 2,611 7/16 79 63 75 56.5 843 19,085 3,049 Zone 2 Total /Ave. 69 60 75 56.0 11,075 231,227 24,072 78 64 75 56.4 11,075 235,696 33,280 Zone 2 Block 9/11 69 60 75 60.1 11,075 181,430 24,072 8/14 78 64 75 60.7 11,075 183,574 37,243 System 1 Total /Ave. 69 60 75 56.0 22,152 462,476 48,144 78 64 75 56.4 22,152 466,460 66,561 System 1 Block 9/11 69 60 75 60.1 22,152 362,859 48,144 8/14 78 64 75 60.7 22,152 362,579 74,486 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM HEATING - ALTERNATIVE 1 Room Number Floor Area Description (Sq Ft) 1 2 3 4 5 6 lobby -1 Zone 1 Total /Ave. Zone 1 Block 7 8 9 10 11 12 lobby -2 Zone 2 Total /Ave. Zone 2 Block System 1 Total /Ave. System 1 Block 384 1,536 768 1,152 4,576 1,024 9,440 9,440 384 1,536 768 1,152 4,576 1,024 9,440 9,440 18,880 18,880 Peak Time Mo /Hr 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 24 13/ 1 24 PEAK BEATING (Main System) Space OA Rm Supp. Cond. Dry Dry DB /WB Blb Bulb (F) (F) (F) 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 Space Air Flow (Cfm) 806 3,809 2,017 1,153 2,448 843 11,076 11,076 806 3,808 2,017 1,153 2,448 843 11,075 11,075 22,152 22,152 LOADS Space Sens. Load (Btuh) -9,082 - 42,922 - 22,730 - 12,994 - 27,582 -9,503 - 124,814 - 124,813 -9,082 - 42,910 - 22,730 - 12,994 - 27,582 -9,503 - 124,802 - 124,802 - 249,616 - 249,615 Peak Time Mo /Hr 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 24 13/ 1 24 OA Rm Cond. Dry DB /WB Blb (F) (F) 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Coil Supp. Dry Bulb (F) 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 V 600 PAGE 5 Coil Coil Air Sens. Flow Load (Cfm) (Btuh) 806 - 13,230 3,809 - 59,860 2,017 - 31,267 1,153 - 24,683 2,448 - 72,743 843 - 19,785 11,076 - 221,568 11,076 - 221,568 806 - 13,230 3,808 - 59,848 2,017 - 31,267 1,153 - 24,683 2,448 - 72,743 843 - 19,785 11,075 - 221,555 11,075 - 221,555 22,152 - 443,123 22,152 - 443,123 Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM HEATING - ALTERNATIVE 1 PEAK HEATING LOADS (Main System) V 600 PAGE 5 Space Coil Peak OA Rm Supp. Space Space Peak OA Rm Supp. Coil Coil Floor Time Cond. Dry Dry Air Sens. Time Cond. Dry Dry Air Sens. Room Area Mo /Hr DB /WB Blb Bulb Flow Load Mo /Hr DB /WB Blb Bulb Flow Load Number Description (Sq Ft) (F) (F) (F) (Cfm) (Btuh) (F) (F) (F) (Cfm) (Btuh) 1 384 13/ 1 24 21 68 78.3 806 -9,082 13/ 1 24 21 68 78.3 806 - 13,230 2 1,536 13/ 1 24 21 68 78.3 3,809 - 42,922 13/ 1 24 21 68 78.3 3,809 - 59,860 3 768 13/ 1 24 21 68 78.3 2,017 - 22,730 13/ 1 24 21 68 78.3 2,017 - 31,267 4 1,152 13/ 1 24 21 68 78.3 1,153 - 12,994 13/ 1 24 21 68 78.3 1,153 - 24,683 5 4,576 13/ 1 24 21 68 78.3 2,448 - 27,582 13/ 1 24 21 68 78.3 2,448 - 72,743 6 lobby -1 1,024 13/ 1 24 21 68 78.3 843 -9,503 13/ 1 24 21 68 78.3 843 - 19,785 Zone 1 Total /Ave. 9,440 24 21 68 78.3 11,076 - 124,814 24 21 68 78.3 11,076 - 221,568 Zone 1 Block 9,440 13/ 1 24 21 68 78.3 11,076 - 124,813 13/ 1 24 21 68 78.3 11,076 - 221,568 7 384 13/ 1 24 21 68 78,3 806 -9,082 13/ 1 24 21 68 78.3 806 - 13,230 8 1,536 13/ 1 24 21 68 78.3 3,808 - 42,910 13/ 1 24 21 68 78.3 3,808 - 59,848 9 768 13/ 1 24 21 68 78.3 2,017 - 22,730 13/ 1 24 21 68 78.3 2,017 - 31,267 10 1,152 13/ 1 24 21 68 78.3 1,153 - 12,994 13/ 1 24 21 68 78.3 1,153 - 24,683 11 4,576 13/ 1 24 21 68 78.3 2,448 - 27,582 13/ 1 24 21 68 78.3 2,448 - 72,743 12 lobby -2 1,024 13/ 1 24 21 68 78.3 843 -9,503 13/ 1 24 21 68 78.3 843 - 19,785 Zone 2 Zbtal /Ave. 9,440 24 21 68 78;3 11,075 - 124,802 24 21 68 78.3 11,075 - 221,555 Zone 2 Block 9,440 13/ 1 24 21 68 78.3 11,075 - 124,802 13/ 1 24 21 68 78.3 11,075 - 221,555 System 1 Total /Ave. 18,880 24 21 68 78.3 22,152 - 249,616 24 21 68 78.3 22,152 - 443,123 System 1 Block 18,880 13/ 1 24 21 68 78.3 22,152 - 249,615 13/ 1 24 21 68 78.3 22,152 - 443,123 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 Room Number Description INTERNAL COOLING LOADS (At time of Space Peak) V 600 PAGE 6 Lights Lights Misc. Misc. Misc. Room Ret. Air Lites People People Peopl Space Space Ret. Air Misc. Sensible Sensible CLF Sensible Latent CLF Sensible Latent Sensible CLF Total (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) 1 1,966 0 1.000 979 979 1.000 1,311 0 0 1.000 5,235 2 7,864 0 1.000 3,917 3,917 1.000 5,242 0 0 1.000 20,940 3 3,932 0 1.000 1,958 1,958 1.000 2,621 0 0 1.000 10,470 4 5,898 0 1.000 2,938 2,938 1.000 3,932 0 0 1.000 15,705 5 23,427 0 1.000 11,669 11,669 1.000 15,618 0 0 1.000 62,382 6 lobby -1 5,242 0 1.000 2,611 2,611 1.000 3,495 0 0 1.000 13,960 Zone 1 Total /Ave. 48,328 0 1.000 24,072 24,072 1.000 32,219 0 0 1.000 128,691 Zone 1 Block 48,328 0 1.000 24,072 24,072 1.000 32,219 0 0 1.000 128,691 7 1,966 0 1.000 979 979 1.000 1,311 0 0 1.000 5,235 8 7,864 0 1.000 3,917 3,917 1.000 5,242 0 0 1.000 20,940 9 3,932 0 1.000 1,958 1,958 1.000 2,621 0 0 1.000 10,470 10 5,898 0 1.000 2,938 2,938 1.000 3,932 0 0 1.000 15,705 11 23,427 0 1.000 11,669 11,669 1.000 15,618 0 0 1.000 62,382 12 lobby -2 5,242 0 1.000 2,611 2,611 1.000 3,495 0 0 1.000 13,960 Zone 2 Total /Ave. 48,328 0 1.000 24,072 24,072 1.000 32,219 0 0 1.000 128,691 Zone 2 Block 48,328 0 1.000 24,072 24,072 1.000 32,219 0 0 1.000 128,691 System 1 Total /Ave. 96,656 0 1.000 48,144 48,144 1.000 64,437 0 0 1.000 257,382 System 1 Block 96,656 0 1.000 48,144 48,144 1.000 64,437 0 0 1.000 257,382 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 INTERNAL HEATING LOADS (At time of Space Peak) Lights Lights Misc. Misc. Room Ret. Air Lites People Peopl Space Ret. Air Misc. Room Sensible Sensible CLF Sensible CLF Sensible Sensible CLF Total Number Description (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) 1 0 0 0.000 0 0.000 0 0 0.000 0 2 0 0 0.000 0 0.000 0 0 0.000 0 3 0 0 0.000 0 0.000 0 0 0.000 0 4 0 0 0.000 0 0.000 0 0 0.000 0 5 0 0 0.000 0 0.000 0 0 0.000 0 6 lobby -1 0 0 0.000 0 0.000 0 0 0.000 0 Zone 1 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 Zone 1 Block 4 0 0 0.000 0 0.000 0 0 0.000 0 7 0 0 0.000 0 0.000 0 0 0.000 0 8 0 0 0.000 0 0.000 0 0 0.000 0 9 0 0 0.000 0 0.000 0 0 0.000 0 10 0 0 0.000 0 0.000 0 0 0.000 0 11 0 0 0.000 0 0.000 0 0 0.000 0 12 lobby -2 0 0 0.000 0 0.000 0 0 0.000 0 Zone 2 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 Zone 2 Block 0 0 0.000 0 0.000 0 0 0.000 0 System 1 Total /Ave, 0 0 0.000 0 0.000 0 0 0.000 0 System 1 Block 0 0 0.000 0 0.000 0 0 0.000 0 V 600 PAGE 7 RE CITY O F. TUK WUA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 V 600 PAGE 8 BUILDING ENVELOPE COOLING LOADS (Roof - Skylight) (At time of Space Peak) Roof Roof Skylight Skylight Return Air Roof Space Roof Skylight Skylight Skylt Return Air Skylt Space Skylt Sensible R.A. Sensible Space Return Air Space Solar Conduction R.A. Conduction Space Room Load CLTD Load CLTD Solar Solar CLF Load CLTD Load CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 2 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 3 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 4 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 5 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 6 lobby -1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Block 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 7 442 38.3 0 38.6 0 0 0.000 0 0.0 0 0.0 8 -542 -11.8 0 -11.5 0 0 0.000 0 0.0 0 0.0 9 -110 -4.8 0 -4.5 0 0 0.000 0 0.0 0 0.0 10 1,356 39.2 0 39.5 0 0 0.000 0 0.0 0 0.0 11 5,756 41.9 0 42.2 0 0 0.000 0 0.0 0 0.0 12 lobby -2 1,178 38.3 0 38.6 0 0 0.000 0 0.0 0 0.0 Zone 2 Total /Ave. 8,079 28.5 0 28.8 0 0 0.000 0 0.0 0 0.0 Zone 2 Block -2,851 -10.1 0 -9.8 0 0 0.000 0 0.0 0 0.0 System 1 Total /Ave. 8,079 28.5 0 28.8 0 0 0.000 0 0.0 0 0.0 System 1 Block -2,851 -10.1 0 -9.8 0 0 0.000 0 0.0 0 0.0 BUILDING ENVELOPE COOLING LOADS (Wall - Window) (At time of Space Peak) Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plenm Space Space Space Return Air Solar Space Space Return Air R.A. Room Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 1 30 5.7 91 6.0 12,240 0 0.980 208 3.1 0 0.0 2 -82 -5.4 -191 -5.1 65,760 0 1.000 -3,199 -11.9 0 0.0 3 11 1.4 28 1.7 34,848 0 0.990 -1,339 -8.3 0 0.0 4 10 0.8 26 1.1 12,768 0 1.000 -1,583 -6.2 0 0.0 5 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 6 lobby -1 35 4.5 136 4.8 5,952 0 1.000 83 3.1 0 0.0 Zone 1 Total /Ave. 3 0.1 89 0.7 131,568 0 0.995 -5,829 -7.5 0 0.0 Zone 1 Block -241 -5.1 -578 -4.8 81,264 0 0.699 -4,677 -6.0 0 0.0 7 30 5.7 91 6.0 12,240 0 0.980 208 3.1 0 0.0 8 -38 -2.5 -82 -2.2 65,280 0 0.980 -2,849 -10.6 0 0.0 9 11 1.4 28 1.7 34,848 0 0.990 -1,339 -8.3 0 0.0 10 10 0.8 26 1.1 12,768 0 1.000 -1,583 -6.2 0 0.0 11 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 12 lobby -2 35 4.5 136 4.8 5,952 0 1.000 83 3.1 RECEIVE 0.0 Zone 2 Total /Ave. 48 1.0 198 1.6 131,088 0 0.985 -5,479 - 7.0ITY OF TUKYVILA 0.0 Zone 2 Block -241 -5.1 -578 -4.8 81,264 0 0.699 -4,677 -6. AR 2 0 1 4 9 8 0.0 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 Room Number Description System 1 Total /Ave. System 1 Block Room Number Description 1 2 3 4 5 6 lobby -1 Zone 1 Total /Ave. Zone 1 Block 7 8 9 10 11 12 lobby -2 Zone 2 Total /Ave. Zone 2 Block System 1 Total /Ave. System 1 Block BUILDING ENVELOPE COOLING LOADS (Wall - Window) (At time of Space Peak) Wall Wall Wall Wall Glass Plenum Plenm Space Space Space Load CLTD Load CLTD Solar (Btuh) (F) (Btuh) (F) (Btuh) 51 0.5 287 1.2 262,656 -482 -5.1 -1,156 -4.8 162,528 BUILDING EN (Exposed Floor (At time of Glass Return Air Solar (Btuh) Glass Solar CLF VELOPE COOLING LOADS - Partitions - Infiltration) Space Peak) Glass Space Conduction (Btuh) V 600 PAGE 9 Glass Glass Glass Space Return Air R.A. CLTD Conduction CLTD (F) (Btuh) (F) 0 0.990 - 11,308 -7.3 0 0.0 0 0.699 -9,354 -6.0 0 0.0 Exposed Expsd Plenm Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total (Btuh) • (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 0 0.0 0 0.0 0 0 0 75.3 33 12,602 0 0.0 0 0.0 0 0 0 75.3 130 62,418 0 0.0 0 0.0 0 0 0 75.3 65 33,613 0 0.0 0 0.0 0 0 0 75.3 98 11,318 0 0.0 0 0.0 0 0 0 75.3 389 389 0 0.0 0 0.0 0 0 0 75.3 87 6,293 0 0.0 0 0.0 0 0 0 75.3 802 126,633 0 0.0 0 0.0 0 0 0 75.3 802 76,570 0 0.0 0 0.0 0 0 0 75.3 33 13,044 0 0.0 0 0.0 0 0 0 75.3 130 61,899 0 0.0 0 0.0 0 0 0 75.3 65 33,503 0 0.0 0 0.0 0 0 0 75.3 98 12,674 0 0.0 0 0.0 0 0 0 75.3 389 6,145 0 0.0 0 0.0 0 0 0 75.3 87 7,471 0 0.0 0 0.0 0 0 0 75.3 802 134,735 0 0.0 0 0.0 0 0 0 75.3 802 73,719 0 0.0 0 0.0 0 0 0 75.3 1,604 261,368 0 0.0 0 0.0 0 0 0 75.3 1,604 150,289 RECEIVED CITY OF TUKWIIA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics V 600 By: Comfort Plus PAGE 10 HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 BUILDING ENVELOPE HEATING LOADS (Roof - Skylight) (At time of Space Peak) Roof Roof Skylight Skylight Return Air Roof Space Roof Skylight Skylight Skylt Return Air Skylt Space Skylt Sensible R.A. Sensible Space Return Air Space Solar Conduction R.A. Conduction Space Room Load CLTD Load CLTD Solar Solar CLF Load CLTD Load CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 2 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 3 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 4 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 5 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 6 lobby -1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Block 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 7 -501 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 8 -2,003 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 9 -1,001 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 10 -1,502 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 11 -5,966 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 12 lobby -2 -1,335 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 Zone 2 Total /Ave. - 12,307 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 Zone 2 Block - 12,307 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 System 1 Total /Ave. - 12,307 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 System 1 Block - 12,307 -43.5 0 -44.0 0 0 0.000 0 0.0 0 0.0 BUILDING ENVELOPE HEATING LOADS (Wall - Window) (At time of Space Peak) Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plenm Space Space Space Return Air Solar Space Space Return Air R.A. Room Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 1 -229 -43.5 -665 -44.0 0 0 0.000 -3,098 -44.0 0 0.0 2 -668 -43.5 -1,647 -44.0 0 0 0.000 - 12,392 -44.0 0 0.0 3 -334 -43.5 -718 -44.0 0 0 0.000 -7,435 -44.0 0 0.0 4 -501 -43.5 -1,024 -44.0 0 0 0.000 - 11,772 -44.0 0 0.0 5 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 6 lobby -1 -334 -43.5 -1,246 -44.0 0 0 0.000 -1,239 -44.0 0 0.0 Zone 1 Total /Ave. -2,065 -43.5 -5,301 -44.0 0 0 0.000 - 35,936 -44.0 0 0.0 Zone 1 Block -2,065 -43.5 -5,301 -44.0 0 0 0.000 - 35,936 -44.0 0 0.0 7 -229 -43.5 -665 -44.0 0 0 0.000 -3,098 -44.0 0 0.0 8 -668 -43.5 -1,647 -44.0 0 0 0.000 - 12,392 -44.0 0 0.0 9 -334 -43.5 -718 -44.0 0 0 0.000 -7,435 -44.0 0 0.0 10 -501 -43.5 -1,024 -44.0 0 0 0.000 - 11,772 -44.0 0 0.0 11 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 12 lobby -2 -334 -43.5 -1,246 -44.0 0 0 0.000 -1,239 -44.0 RECEIVE 0.0 Zone 2 Total /Ave. -2,065 -43.5 -5,301 -44.0 0 0 0.000 - 35,936 -44d of TuKJJILA 0.0 Zone 2 Block -2,065 -43.5 -5,301 -44.0 0 0 0.000 - 35,936 -44.0 0 0.0 MAR 2 0 1998 HERMIT CENT=.,;;; Trane Air Conditioning Economics By: Comfort Plus Room Number Description HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 BUILDING ENVELOPE HEATING LOADS (Wall - Window) (At time of Space Peak) V 600 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER PAGE 11 Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plenm Space Space Space Return Air Solar Space Space Return Air R.A. Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) System 1 Total /Ave. -4,130 -43.5 - 10,602 -44.0 0 0 0.000 - 71,872 -44.0 0 0.0 System 1 Block -4,130 -43.5 - 10,602 -44.0 0 0 0.000 - 71,872 -44.0 0 0.0 BUILDING ENVELOPE HEATING LOADS (Exposed Floor - Partitions - Infiltration) (At time of Space Peak) Exposed Expsd Plenm Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Room Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total Number Description (Btuh) (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 1 0 0.0 0 0.0 0 0 0 67.5 -66 -4,059 2 0 0.0 0 0.0 0 0 0 67.5 -264 - 14,970 3 0 0.0 0 0.0 0 0 0 67.5 -132 -8,619 4 0 0.0 0 0.0 0 0 0 67.5 -198 - 13,495 5 0 0.0 0 0.0 0 0 0 67.5 -786 -786 6 lobby -1 0 0.0 0 0.0 0 0 0 67.5 -176 -2,995 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0 67.5 -1,621 - 44,924 Zone 1 Block 0 0.0 0 0.0 0 0 0 67.5 -1,621 - 44,924 7 0 0.0 0 0.0 0 0 0 67.5 -66 -4,559 8 0 0.0 0 0.0 0 0 0 67.5 -264, -16,973 9 0 0.0 0 0.0 0 0 0 67.5 -132 -9,620 10 0 0.0 0 0.0 0 0 0 67.5 -198 - 14,997 11 0 0.0 0 0.0 0 0 0 67.5 -786 -6,752 12 lobby -2 0 ' 0.0 0 0.0 0 0 0 67.5 -176 -4,330 Zone 2 Total /Ave. 0 0.0 0 0.0 0 0 0 67.5 -1,621 - 57,231 Zone 2 Block 0 0.0 0 0.0 0 0 0 67.5 -1,621 - 57,231 System 1 Total /Ave. 0 0.0 0 0.0 0 -1 0 67.5 -3,243 - 102,155 System 1 Block 0 0.0 0 0.0 0 0 0 67.5 -3,243 - 102,154 • Trane Air Conditioning Economics By: Comfort Plus BUILDING U- VALUES - ALTERNATIVE 1 BUILDING U- VALUES Room U- Values Room Room (Btu /hr /sqft /F) Mass Capac. Room Summr Wintr Summr Wintr (lb/ (Btu/ Number Description Part. ExFlr Skylt Skylt Roof Windo Windo Wall Ceil. sqft) sqft /F) 1 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 122.8 24.30 2 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 84.1 16.66 3 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 77.7 15.39 4 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 75.6 14.97 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.317 13.3 2.67 6 lobby -1 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 85.7 16.98 Zone 1 Total /Ave. 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 50.0 9.91 7 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 174.9 35.62 8 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 136.3 27.99 9 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 129.8 26.71 10 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 127.7 26.29 11 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.317 65.5 13.99 12 lobby -2 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 137.9 28.30 Zone 2 Total /Ave. 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 102.1 21.24 System 1 Total /Ave, 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 76.1 15.57 Building 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 76.1 15.57 V 600 PAGE 12 By: Comfort Plus BUILDING AREAS - ALTERNATIVE 1 ASHRAE 90 ANALYSIS - ALTERNATIVE 1 Trane Air Conditioning Economics V 600 PAGE 13 Floor Total Exposed Number of Area /Dupl Floor Partition Floor Skylight Skl Net Roof Window Win Net Wall Room Duplicate Room Area Area Area Area /Rf Area Area /W1 Area Number Description Flr Rm (sqft) (sqft) (sqft) (sqft) (sqft) ( %) (sqft) (sqft) ( %) (sqft) 1 1 1 384 384 0 0 0 0 0 120 23 408 2 1 1 1,536 1,536 0 0 0 0 0 480 31 1,056 3 1 1 768 768 0 0 0 0 0 288 38 480 4 1 1 1,152 1,152 0 0 0 0 0 456 40 696 5 1 1 4,576 4,576 0 0 0 0 0 0 0 0 6 lobby -1 1 1 1,024 1,024 0 0 0 0 0 48 6 720 Zone 1 Total /Ave. 9,440 0 0 0 0 0 1,392 29 3,360 7 1 1 384 384 0 0 0 0 384 120 23 408 8 1 1 1,536 1,536 0 0 0 0 1,536 480 31 1,056 9 1 1 768 768 0 0 0 0 768 288 38 480 10 1 1 1,152 1,152 0 0 0 0 1,152 456 40 696 11 1 1 4,576 4,576 0 0 0 0 4,576 0 0 0 12 lobby -2 1 1 1,024 1,024 0 0 0 0 1,024 48 6 720 Zone 2 Total /Ave. 9,440 0 0 0 0 9,440 1,392 29 3,360 System 1 Total /Ave. 18,880 0 0 0 0 9,440 2,784 29 6,720 Building 18,880 0 0 0 0 9,440 2,784 29 6,720 ASHRAE 90 ANALYSIS Overall Roof U -Value = 0.030 (Btu /Hr /Sq Ft /F) Overall Wall U -Value = 0,199 (Btu /Hr /Sq Ft /F) Overall Building U -Value = 0.115 (Btu /Hr /Sq Ft /F) BUILDING AREAS Roof Overall Thermal Transfer Value ( OTTVr) = 0.40 (Btu /Hr /Sq Ft) Wall Overall Thermal Transfer Value (OTTVw) = 25.40 (Btu /Hr /Sq Ft) RECEIVED CITY OF TUKWILA MAR 2.0 1998 • ?ERMI V CENTc; , City of Tukwila Fire Department Fire Department Review Control #M98 -0057 (512) Dear Sir: March 25, 1998 Re: Boeing Employees Credit Union - 645 Andover Park West The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written.approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Call the Tukwila Fire Department at 575 -4407 for John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 375-4404 • Fax (206) .575-4439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 2 approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Maadaua,tes Station: 444 Andover Park East . Tukwila. Washington 98188 Phone: (206) S75-4404 • Fax (206) 575.4 ?9 / C 1° is lf� ° ii 1- 111 01 I,� J�111lI� �ILII�� -- IIIII� L. II��, � !�11111������111�IINImlillll�il 111® III1III :I� ■�!:.IMIII 1.___ -!!!!I IJI '�I .IIIIII 'd �lll ' �IIIII 'VIII Ii �, III F i�■.■■.n�P;!J1. ■ice lifl2i11UU.oIU111I1111G�11t, �o ��re■�. ,vh III II IIIIII , \,!1 I ! l 7 ; JflI 1III �!_ �.�r�illl ' • 111 ; ,IIIII�I>rf . J h'!'IIhI1rJiH :i1IH1G1iIuI F 1 li ii IIIII'•I�� , si�_�n�ul■�, I Iu l Is I _I I_I --- ' I , \a� \w uwl I nmr IIIIIIIIIIIIIHIIIIIIILJIIIII _ I'.. },_ II Ill I.uIiuiI! iIliulbe' . iI �W ip, I�Ii lli . I ° 11I.� -1111 II Ilmlalu•l '- I ■U4!! IJ. /1111 • TII1 I.. ....Solf #lv o�ll II 111111IF!llily ° r i 1T. I _ .o.ow. I ! ! ! ! I I_�....I■riliiNINhurh� LI — _! _ c u ® - h o ®Illlim lll�...L . 1""111 �i■■• 11l!11IIII ,� �� 'I��� 1 in � Z ' I Ilfl'UI!11��I'� �'Iu11J'll�ill b..., i;� I y t• I �111111111�1f� IIAIIII® v I 1029 J Fi6?�4DE m)PC1LA1ED &B -BASE GRILLE I, U w J z �o , i M9s -oos� UPPER FLOOR PLAN F'fmVIDE oM8tLLA1ED ele -fJAeE LOWER FLOOR PLAN, l /8 . - I. -0. KEY PLAN NTUS. ! - PROVD7E rl)l&LATED eue -EA6E ■..■ ;mAPIDON �.i■. i.�U■d © ..nu. tii � i JIB ' h P1L1�1�1 IIf1= .IlIillIjIlpIPAiIII11111 '° I�j:., II ,- '�- ®',,�910:11111��Callaoc'III:� raovmE •m�dAtED e8 -saeE • 'o, � ! e1E -BasE 11111►M111111111C�'� IIl1I_g1 _1 f 11II1I1►r -I III_ ® = !!!„ I, IIII ® ®� ��iYi10` III' - , 1h►.1 IIIl�illir�I�IR ®►��_�__ -�1 ' Il11ii�ll'1:`�Ilol!1!1@lill!11' u l.. - ��;111111111 - -'' IIB�11 ®I_I 111�i ®ern 6 111 -111 . 111 ��ml' ®;�lil`itll I���01L..� , �� ■�■, Ii11I11111111i111111i Ii�11i11I111III 1 I IIII�NII�l1 E u �I �Illl �I ®111111111 111��111� 8111!,NI11 JI1 !!-Il�I 11I II11111II1iI i!1Ih� ci!1hIO1l HI ! - 1111111 ��� ,�IIIII ���.��i® IjiIUTIIUUl _- JII ®lilll _ 1 =1!!1111 ��.,,,,, � I� i®Ri ®®■' i 14e �i■Illll�■.11u III 02 '1111�IIr1o� "_ I�I�IIIIIIIIIII111m °'C�. , iii C l = 1�! , _ �.� �p�l ®��ws l��llll l►���1I111111�Ii `IIIIII�, °,�1I� ®!Illl�illlll%�.!_,�l,! o @ �' � ..� S:a ��4 ■��-1� F13T0DE m/IN3IAATED ) 3 © 111D/iP11'h1111[1I T i BE -BASE - !l i Ii 1 i Jii!IIMI . ' fiE III ®1l!&! _� - II 2� ill' ._. II .! II 2• -i j 201 I ,"2 .03 ) a 205 > 206 20, m 208 203 210 1 211 2Q NOTES: al 24k 24R4 (R 24kQFAG)FOR LOCAL fl It'7 AIR TO VAV DO)C GRLLLE I8 E2 6T t e411l 8E R L ATFD TO IAGATION IId2K.A1ED. D(TETIDIPPDV DE IEVI DUCT FTdT7 GPoLLE TO XI VG V A V EOX I H THe AREA PR7J P€ WL P(PR • VAV RA PLE U9 O 24k 24744 (OR 24kQFAG)FOR GBERAL RA TO Gii11R41 WIT. GIeILLE C Da$TYa 1 eNALI. OE RELOCATED TO LOOATIRI PdOICATED. EXIETD)PImVDE PEW 16'1 DUCT FR7M GRILLE TO EX1S G cB71R�1L RA T. PPE VDL DMPR • w2+TRUx O FELOCAIED T -BTAT. VERIFY ACTUAL LOCATION cT1 SITE .+T:PI DYs PRIOR TO RAYa44- L 04 RELOCATE EX BTG FPVAVNAV COX AS INDICATED. EX2Q✓D EXT5V SUPPLY AIR DUCT As READ. O5 NE,U FAH FlO 0ERED VAV 1P VAV) OR COiOLN Q.ILY (VAV) COX F%1PE COMECTIR4 TO EXIBTYa PRn'IARf &IPPLT AIR DUCT A8 REQD, SVE FER BOX 41ET. PRJ 1PE c/dUPPL1 1 RET1.3I AIR F2.EN1'78 Ab IJDIC4IED. b x.6$ I�TCAIED Ot1WED(LE ELOO O RE D(Iett Eat PI'E1T / 1B71FN TO o 1R RETIOVE DC1111b1RE 11 DUCT / O RL - 11R AIR 1R 2 R ASBEIBLT eVGRD 8I MDOATED. FOR 24' z Q' GRILLE&, MTEfx'OItEGTMG DUCT 8#4U. BE Q•4. FOR 24' x 24 GRILLES PROVIDE 16'I OUCT. I MAP kTb. DIFFUSER SCHEDULE LAi RAIY� GD IEOC el 0 -100 6'x6' IOI-2� 8•x8' 201 -360 10'x10' 38I-C� Q' x Q' 2I- 6b0 I4 x14• b81 - e80 16'x16' 81-IQ5 Wxb' v4v SCHEDULE I'bYJFA•IOD MDUCTO/30F10 @IDUC70/3FFJ0 MDUCTO03tIF15 INDUCTO/ ilIDUGTOhF51000 IIH3.Jc7O/ MDUCTO/ UDIICiO, 11mU,''f0/ REDDI/ ROUCTOOVO5 MDUCTO/ I1cucT0/30F15 ra:TAL rt1D/ TRIIBh1'FV TRUB?fiFV ItmUGTOlilfrl5 REDDI/ MDUCTO/31FI5 n1D�0/ PIDucTOn,FO000 MDUao/ RIDUCTO/ REDDI/ REDDI/ lraucro/ nrouctor3(ar52o TINBrfTfV j y1 200 10 480/3 VAY &ELEC DaCT COIL 1600 n 4800 YAY &ELEC DUCT COIL 1600 400 3 2l1/! YAY m/ELEC DUCT COILS 2000 205 480/3 Ff'VAY Q00 800 5 n1n VAV u rFI Ff DUCT COIL 20'0 4 2T10 VAV uJELEC DUCT COIL Q00 200 3 800 115 200 lomm 600 4 3 2nn 480/3 2 2TT,1 2110 800 13 .4800 VA'. W/ELEC DUCT COIL 200 5 211/1 VAV CLEC DUCT COIL CO 13 480/3 VAV 2ELEC 0200 COIL 1600 1500 22 480/3 VAV uvELEC DUCT COILS 1200 400 400 3 2110 VAV m/ELEC DUCT COIL 600 2 2110 VAV a/ELEC DUCT COIL 200 1600 n 4800 YAV m/E! EC DUCT GAIL 600 3 211,1 IEUR YAV EXHAUST FAN SCHEDULE FS 4 R- 10.41E LR1 • U25• 8P, B0 U441 Q�C 100M RPI7 WNTEGRAL BAQCR4FT OTPR I INIT MOJITED 6P® &UTCN 1 10'e DUCT UP TO ROOF WOOD. CC lTR7L m/FECERBE ACTMa 1}ER'1OSTAT BET TO ACTIVATE FAN • 15' F. (AD.1$TAE>LE) 11412 20T . 36•e. pgR i • NUMBER DUCT(BPB4 -M SIZE 8Y Q.e µ• µY 16Y /,1.1. A8 NOTED VAV m/ELEC DUCT COIL VAY w/ELEC CUG' COIL vAV a/ELEC DIIC' COIL IEUIFPraV NEW FPVAV �OPY zdP i dthat the Pl 1- '' ` - M 'iS -0051 R108 /9B QBVlNen RECU. n--ort \2-N peo. A.O. C P.• 3/2/38 BECO TM hQrarwril DATE R E V I S I O N S I f 1T� 6617 S. 193rd Place, Suite #P105 KENT. WA 98032 4253251 -9840 425 251 -9871 (Fax) oar tl Id /� Corporate Sc uare Bullding' x 6Outicenter Cor .$gCre Andover Park Weot Tulaulle, 94 I-IV,4C Floor Plans - Sldg 6 I'.I!I�lil� iti FiECE�VED Cott OF TUKWILA 292 2 11 13 PEPMIT GENTEFi M -I