HomeMy WebLinkAboutPermit M98-0058 - BOEING EMPLOYEES CREDIT UNION (BECU)bDel �r& p kx J ee3 Cad i� L\rvor'u ■NkCIR-DO City of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0058 Type: B -MECH Category: NRES Address: 625 ANDOVER PK W Location: BUILDING #5 Parcel #: 262304 -9075 Contractor License No: COMFOP *064D2 TENANT BOEING EMPLOYEES CREDIT UNION 625 ANDOVER PK W, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTRACTOR COMFORT PLUS Phone: .206 251 -9840 PO BOX 913, KENT WA 98032 CONTACT HERB JACKSON Phone: 425 - 251 -9840 6617 S 193 PL, #P -105, KENT, WA 98032 k******************************************** ** ** * ** * * * ** *. * ** * * * * * ** * * * * *** Permit Description: INSTALL 5 NEW VAV BOXES, 21 NEW T /S, 5 S /FDAMPERS 2 EXHAUST FANS, RELOCATE AIR DISTRIBUTION. Valuation: 32,098.00 Total Permit Fee: 88.75 * * * * * * * * * * ** *********** * * * * * * * * * * * * * * * ** * * * * * * * * * *** *tilt * * * * * * * * * * * *** UMC Edition: 1994 * * ** MECHANICAL PERMIT (206) 431 -3670 Status: ISSUED Issued: 04/14/1998 Expires: 10/11/1998 _L Pernit Center Authorized Signature Date I hereby certify that I have read and examined this permit .and know' the same to be true and correct. All provisions of law and•ordinances governing this work will be complied with,' whether specified, herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state :or, local laws regulating construction or the performance of work: I am authorized to sign for and obtain this building permit. Signature : _,�1i•,,# �� Date: Print Name: Cry ����`� 3� Title:____„ _ This permit shall become null.,and void if the work ;is not commenced within 180 days from the date of issuance, : .or, i f the : work is suspended or abandoned for a period of 180 `days''from:.the last inspection. Project Name/Tenant: C Description of work to bed e: _L t, l a•(( ?1 24 n 5 .5/F C11446T, z eK li ro.4-st ,S ! rioCAlt al v CI I Sir <.. `1 i 61, . . Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 7:1? Attach list of materials and stora.e location on se•arate 8 1/2 X 11 •a•erindicatin• •uantities & Material Safet Data Sheets Value of Construction: 4' 3z cle_e.o Site Addr ss• t OP-5+"/ bwi .1 City Siate /Zip: II (` i0 . `�8( Tax Parcel Number: x ' 2.1 « �. - /o f ci! 4 Property Owner: Loam- iiq 10 i�1 U '� City /State /Zip: P4ene: _ (esx.) 5 7� - Z 1 2.0 Street Address: U n i Vess sf : z�zc, 5 . 1 . - �{l� . �iVe�. City State /Zip: P3 1 Fax #: Contact Person: - , v � � /c�- S CI : on za� eS7 - 9840 Street Address: ( r7 55. f43 ( ?(0S Idit. 9 City State /Zip: •x #• _ - - :„ qne: !^ 840 t- �z.�ZS Contrac .{'� t�.5 ? Street Address: ca, (7 55. (`13 ^ � t fa y' I 9 606.. City State /Zip: 632 F #: ( z.. z57 ^981 Architect: ., Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT'BYAPPLICANT) , 6" 1IiV L'Kej 'T Description of work to bed e: _L t, l a•(( ?1 24 n 5 .5/F C11446T, z eK li ro.4-st ,S ! rioCAlt al v CI I Sir <.. `1 i 61, . . Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 7:1? Attach list of materials and stora.e location on se•arate 8 1/2 X 11 •a•erindicatin• •uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition ❑ Fence Mechanical ❑ Manufactured Housing- Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF T "(WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST.FOR MISCELLANEOUS PUBLIC. WORKS PERMITS': ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 3 4o l t MISCPMT.DOC 7/11/96 Date application expires: 14-W •,t• Appll tlo taken by: (Initials) BUILDING O N :R O • AUTHORIZE ' AGEN : ri Antennas /Satellite Dishes Date: Sign. Awnings /Canopies - No signage Commercial Tenant Improvement Permit Print name: • in : a�l � (' ate 'p: girt G( '4. 9803z- L Address: t7 5 :. , .—it 143 - ^( 0 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist No: M -9 ri Antennas /Satellite Dishes Submit checklist No: M -1 0 Awnings /Canopies - No signage Commercial Tenant Improvement Permit ri Bulkhead /Dock Submit checklist No: M -10 Ell Commercial Reroof Submit checklist No: M -6 in Demolition Submit checklist No: M -3, M -3a 0 Fences - Over 6 feet in Height Submit checklist No: M -9 in Land Altering /Grading /Preloads Submit checklist No: M -2 J Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 Mechanical (Residential & Commercial) Submit checklist No. M -8, Residential only - H -6, H -16 ri Miscellaneous Public Works Permits Submit checklist No: H -9 in Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M -5 J Moving Oversized Load /Hauling Submit checklist No: M -5 Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 0 Retaining Walls - Over 4 feet in height Submit checklist No: M -1 n Temporary Facilities Submit checklist No: M -7 0 Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 n Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PE - 'IT APPLICATIONS MUST BE SUEM ED WITH THE FOLLOWING: ➢ R11RAWIIiGAii, BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ ILDIA)G AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC '' :'` r.IV •4 .1' CITY OF TII}:WILA Address: 625 ANDOVER PK W Suite: Tenant: BOEING EMPLOYEES CREDIT UNION Type: B -MECH Parcel #:262304 -9075 Permit No: M98 -0058 Status: ISSUED Applied: 03/20/1998 Issued: 04/14/1998 *• k• k***** k*' k• k• kk*** k• k• k• k kk• k k*; kk*** k• k* kk k• k******* k***** • k* *•A*•k * *•kk *k**** ***k•k Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and th,e., TuF::ati.ia Building Division: 2 All permits, inspection,, >r ecor` s; and ..'apprdyed plans shall be available at the Job r ite`prior to "the s.tart ..of any con- -; .. struction. Tt•rese ::sisocuiirent .'are to „•be rnairitalne°d. and avail- able until final i'nspe_ct1on r 'appr oval is granted r r 3. All construct.,ion to be done :in with approved plans and :requirerpents_of the Uniform Bui1ding,.Code:.,994 Edition) 'amende'd, Lin iform'`Mechan ica:.1,, Code( 1;994, Ect , and Washington State Energy Co,de (1994 Ed 4. Va l i d i.ty •of Permit. , The issuance of a perrn`t iv ors, appr`ova'1, .of s,, plan,. specificati and ; Computations d Computation shall , con ` strue.d °to ='`�be a permit for ' `'or an approval of, any v i.o1`a n t io° :. of any : ' of -' "t�h.e prov i s ions of `:the.., i 1 d i ng code or `', ',an y other ordinance of the.., juris�dl'ct.ion; No permit pre um1 °ng give authority' to violate ordcancei `the provisions :,of code, s,ha 1''1' `be v a l i d . , d 5. MANUFACTURERS INSTALLATION 1N.TR.ULTIIONS,REUUIREt FOR ,THE BUILDING IN PECTOR':, REVIEW; 6. Electrical : permits ? ha11::. bi':obtaine'�i;`th r' the Wcshingtgn State Dl v.'ii s i on of Labor and 'Industr~i s ' ll e and , all i e , s e c t r i c a`1`�. wor l wi 11 'be elnspectedby that ',,agen'cy ( 248 -6630) °y r11 +Mi ACTIVITY NUMBER: M98 -0058 DATE: 3 -20 -98 PROJECT NAME: DEPARTMENT: B(a'Iding Division (I 44 Z. P 6 ublic Works n k» 31ag1ctC Approved C \PR•ROUTE.DOC 1/98 C C 1'airyu� £ooW. Cs)pbt PLAN REVIE /ROUTING SLIP APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: BOEING EMPLOYEES CREDIT UNION Fire revention Struca � DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete 17 Incomplete ❑ Comments: TUES /THURS ROUTING: Please Route ❑ Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: Planning Division E u Per \ m � it c�ordmator DUE DATE: 3 -24 -98 Not Applicable E No further Review Required DUE DATE: 4-7 -98 REVIEWERS INITIALS: DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ DUE DATE: Approved with Conditions ❑ Not Approved (attach comments) El REVIEWERS INITIALS: DATE: F625-052-000 (8/97) . DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY AA AF 7f4,:jiafREqsTRATIoN!„JgumpE gc4A1AFP0MFPPL EFFECTIVEII COMFORT PLUS 6617 S .193RD OK STE P 105 KENT WA 98032-2197 1 *? A•k•kA * *44.A****•k *••1* 5 : * ** * * *l k*****#** A•* * * * * * �rA * A.11 * *A *44,4.8*A ** *A*A CITY OF TUI(WILA, WA .TRANSMIT' * **•kA* *A *A•*' * ***•.k* rot: k**• k* A******* A• * *•;4*k. *+4***,t* ** *.S * ****A* '/t*.' *** TRANSMIT.: Number: R9700746 'Amount;: • 88.75 O4/14/9E{ 155'59 PaymenG,.,Methoda CHECK Notation: COMFORT PLUS Init: .q.LH Permit No M98 -0058 Type: n- -MECH; MECHANICAL PERMIT Parcel No: 262304 -9075 Site Address: 625 ANDOVER PI(. W Location: BUILDING t15 'total Feeb: 08.75' This Payment 01.7; Total ALL Pmts: E18.75. Balance .p(!'_ Ah• *A•A ,***** 4 •* 11** A******* 4 ***. t• k**• k, **** ot** ** * ** ** ks1•k4* *A * *ll ktilrk'k *lI* Accoun !Cede. Description AIflOUht,. .000/345:.830 PLAN CHECK NONRES ; 17.75 000/322.100 : MECHANICAL NONRI:r • • 71.00_. 1,17777777 • Project: -- Type of inspecti n: Address: (e 7.s A. ' 10-v.1 . Date called: f----- Special instructions: Date wanted: G c /1 r r a.m. p.m. Requester: I( Phone No.: . ,d:`S'�';�.• i6t��'!��t+i'�ra' ,, Cn,sstS: �-.rae'.�.f""""•.nr COMMENTS: $42.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 7 Approved per applicable codes. INSPECTION RECORD Retain a copy with per 1 1 ��. w �. •»:+av �v+� o s,�.7, ids; VII 9 -oast PERMIT NO. (206). 431 -3670 Corrections required prior to approval. Project: �� Type of fps .E" ion a f � Address: 1 Z-6 A ` VV Date call 5 / z Date wanted: S / xA f 0 p.m. a.r Special instructions: 05( • S Requester: Phone No.: COMMENTS: Inspector: Date: ..s z6 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calrto schedule relnspection. Receipt No.: Date: r' a^ ""f tQh .t;i )14.fganr"AV ;.;' itr A VTAifP0,1•Vo.ica..vi,"1 J INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with perml_J [ 1 IAA '40.58 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 -/5( (206) 431 -3670 Corrections required prior to approval. Project% p T •e of i •pection: Aik ..• Address: ( I 1/v Da e =d _ c)$ Special instructions: � ri. t Date wanted: L / x w G d'1D `Y lC� p.m. Requester � a� �'� N p � P T � o � - - a.v.._ 1 1 s l INSPECTION NO. ntrirs � i�n&•'YS*v t��dQr tirmoerAi tA4r rsoaviiiniuom►i s,,,iv. .: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: �•J INSPECTION RECORD Retain a copy with perm [1 Date: PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTI • N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: Project: , .;r. � • (� IA 1 Typ f insp ctio -- - O 1/ , , -f-. 4"Y gtyatiedi. 4 Addr ' l/ 5 . Lc) Special instructions: 2 ,., h a /---(042 f Date wanted: ( I'2) -� -9E r Requester: 3 d Phone No.: y s ... 5) / q /�� pi INSPECT •N NO. INSPECTION RECORD Retain a copy with permi CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 . k, - n — tOrrK"e[ Date: -0058 PERMIT NO. (206) 431 -3670 7( Approved per applicable codes. I 1 Corrections required prior to approval. COMMENTS: • $42,OO SPECTION E REQ UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule relnspection, Receipt No.: Balance Due: $ Sa.15 Need Current Contractor Registration Card: ❑ Yes Need to Enter Contractor Information in Sierra: ❑ Yes �%� iii• . o a ct . o :::::s<.. >:«:�:: > f: v: , l ; : };•:��: >: ....Y I . I l'.4 4_; !. i 's. .__ • Balance Due: $ Sa.15 Need Current Contractor Registration Card: ❑ Yes Need to Enter Contractor Information in Sierra: ❑ Yes GREE IVH�K g L Corridor Ceiling FIRE SMOKE DAMPER �� DAMPERS AND LOUVERS Application and Design Model CFSD -23 is a combination fire smoke damper UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model's operational ratings, of up to 3000 fpm and 8" w.g., far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings — providing an extra measure of safety. Model CFSD -23 is rated for air flow and leakage in either direction. Ratings Fire Resistance: Leakage: Pressure: Velocity: Temperature: UL rating of 1 hour for corridor ceilings UL 555S leakage class I (to 8 in. w.g.) Leakage rated in both directions 8 in. w.g. - differential pressure Dynamic and operational rated to 3000 fpm. Rating is for airflow in either direction through damper. 350° with all actuators. Higher temperature ratings with some actuators. Fire tested to 1800 °F. Standard Construction Frame: 5 "x1" galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 17" high to maximize free area and performance. Blades: 16 ga. galvanized steel, reinforced with 3 longitudinal structurally designed vee's. Seals: Extruded silicone rubber blade seals. Flexible stainless steel jamb seals. Concealed in jamb. UL listed 165 °F. 1 /2" dia. plated steel. Bronze sleeve type. Linkage: Fusible Link: Axles: Bearings: Size Limitations Minimum Size: 8" W x 6" H Maximum Size: 24" W x 24" H Optional Features: • Galvanized steel sleeves. • Stainless steel bearings • OCI (Open closed indication switches) • 212 °F fuse links (other temperatures available, consult Greenheck) • TOR (remote override of 165 °F closure. Allows damper to perform smoke management functions during a fire emergency.) • Electric or pneumatic actuators to accomplish smoke management and system functions. Model CFSD -23 meets the requirements for corridor ceiling dampers, smoke dampers and combination fire /smoke dampers established by: National Fire Protection Association NFPA Standards 90A, 92A, 92B & 101 BOCA National Building Codes ICBO Uniform Building Codes SBCCI Standard Building Codes City of Los Angeles CSFM California State Fire Marshall Listing #: 3230 - 0981:105, 3230 - 0981:106 _` J "UL CLASSIFIED (see complete marking on product)" "UL CLASSIFIED to Canadian safety standards (see complete marking on product)" Standard 555, 555S (Listing #R15439) "W & H dimensions furnished approximately 1 /4" undersize. C�1ar r.• Model CFSD -23 Steel 3 -V Blades UL 555S Leakage Class 1 C • � CFSD -23 06.97 CITY RECEIVED Qty W H Fusible Link Temp. Actuator Model A Dimension Sleeve Length Ga. CI TY O F E � . tiAl, v/1 Project Location MAR 0 1998 Contractor Design Specifier • acit PE CffNTER GREE IVH�K g L Corridor Ceiling FIRE SMOKE DAMPER �� DAMPERS AND LOUVERS Application and Design Model CFSD -23 is a combination fire smoke damper UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model's operational ratings, of up to 3000 fpm and 8" w.g., far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings — providing an extra measure of safety. Model CFSD -23 is rated for air flow and leakage in either direction. Ratings Fire Resistance: Leakage: Pressure: Velocity: Temperature: UL rating of 1 hour for corridor ceilings UL 555S leakage class I (to 8 in. w.g.) Leakage rated in both directions 8 in. w.g. - differential pressure Dynamic and operational rated to 3000 fpm. Rating is for airflow in either direction through damper. 350° with all actuators. Higher temperature ratings with some actuators. Fire tested to 1800 °F. Standard Construction Frame: 5 "x1" galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 17" high to maximize free area and performance. Blades: 16 ga. galvanized steel, reinforced with 3 longitudinal structurally designed vee's. Seals: Extruded silicone rubber blade seals. Flexible stainless steel jamb seals. Concealed in jamb. UL listed 165 °F. 1 /2" dia. plated steel. Bronze sleeve type. Linkage: Fusible Link: Axles: Bearings: Size Limitations Minimum Size: 8" W x 6" H Maximum Size: 24" W x 24" H Optional Features: • Galvanized steel sleeves. • Stainless steel bearings • OCI (Open closed indication switches) • 212 °F fuse links (other temperatures available, consult Greenheck) • TOR (remote override of 165 °F closure. Allows damper to perform smoke management functions during a fire emergency.) • Electric or pneumatic actuators to accomplish smoke management and system functions. Model CFSD -23 meets the requirements for corridor ceiling dampers, smoke dampers and combination fire /smoke dampers established by: National Fire Protection Association NFPA Standards 90A, 92A, 92B & 101 BOCA National Building Codes ICBO Uniform Building Codes SBCCI Standard Building Codes City of Los Angeles CSFM California State Fire Marshall Listing #: 3230 - 0981:105, 3230 - 0981:106 _` J "UL CLASSIFIED (see complete marking on product)" "UL CLASSIFIED to Canadian safety standards (see complete marking on product)" Standard 555, 555S (Listing #R15439) "W & H dimensions furnished approximately 1 /4" undersize. C�1ar r.• Model CFSD -23 Steel 3 -V Blades UL 555S Leakage Class 1 C • � CFSD -23 06.97 CITY RECEIVED PRESSURE DFCP DATA This pressure drop testing was conducted in accordance with AMCA Standard 500 using the three configurations shown. All data has been corrected to represent standard air at a density of .075 lb/ft Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 10 9 6 7 6 5 xtxiwtxaMIxi IMENUMEN ___.•• sssss>••�t� •�st• �•�•B•itttttt'�1•�•188 MUM 11.1 ••11111111 MUM MUNIIIIIIIIIIII 1111111 5 5 11111 111111 / 5 . 2 11111 IIIIH / 5.3 liii C•tMII•••IIIINVr /M111 rt••11•1•In IIIIIIIIIIIIIIMIOAWIMIIIIIIIIIIIIIIIIIII IMMIIIIISIVIIIUMMUffin Uo11117M1 IU11i 11 xarIIri•i tixi1•101111111111•1=1111•11•1urr 9xIENIAruININIMINIssMININNIrMEr•r /Mr ••11•11•11•11•11M11•m•rre••■ ............ lli.it•••..■ •/I II ��.U•■uI •'i� 1 imuiui11 ■ 41111 �•uii1111 111111 LIMO IIIPIiIIIIIII 2 3 4 1 8 • 5 .3 .d06 .07 .06 .05 .04 Damper Size 12" x 12" 4 6 •73910 81000 Velocity (fpm) Figure 5.3 Figure 5.2 p Figure 5.5 E> to 9 8 7 6 5 4 3 2 1 .8 .7 .6 .5 .4 .3 .2 .00 .07 .06 .05 .04 .03 .02 513 61) 4 6 978910 8100 1 =1 • Damper Size 24" x 24" 60 5.5 52 2 3 4 5 979910 81000 Velocity ((pm) CFSD -23 CONFIGURATION D= (MN) V 3.14 CFSD -23 is available in 3 different configurat below illustrate these different configuration Configuration #1 - Fire Rated Actuator (I Configuration #2 - Fire Rated Actuator (I Configuration #3 - Fire Rated Actuator (I F re Rated Ceiling Grille (by others) Fire Rated Ceiling V F Fire Rated Ce ling 'X' L r L 'H' H 6 Finished Ceiling Below I a Grille (by others) Actuator Space' Envelopes Siebe Landis & Staefa MA -220 Serie MA -230 Series 331 -4551 'X' Dimension 5.875" 7.5" Minimum Width 12" 13" (18" w/ options) Minimum Height 12" 18" 'A' = 'X' + Depth of Grille Consult factory if 'A' is greater than 9.5" CONFIGURATIONS CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille } f A 'X' L J Fire Rated Ceiling Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling 5" — / /J/ I/ / / / / / /// ��� \ \,, \ \�`� \` \� A Fire Rated Ceiling Grille (by others) Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Fire Rated Co ling 1 L 'H' H 4 Finished Coiling Below Grille (by others) 'H' 1 A 'A' A 5" 16" 'A' A Sleeve Length 4 Min. r v 'A' 1 Sleeve Length c SPACE ENVELOPES • Consult factory for dampers under 12" high. f Options Include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted intemally or extemally. 'A' Dimension Standard Minimum Sleeve Length With OCI, RRL, or TOR, 11 dimension less than 10" 11 3 /1e" 20" All other dampers 7 She" 16" CONFIGURATIONS CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille } f A 'X' L J Fire Rated Ceiling Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling 5" — / /J/ I/ / / / / / /// ��� \ \,, \ \�`� \` \� A Fire Rated Ceiling Grille (by others) Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Fire Rated Co ling 1 L 'H' H 4 Finished Coiling Below Grille (by others) 'H' 1 A 'A' A 5" 16" 'A' A Sleeve Length 4 Min. r v 'A' 1 Sleeve Length c SPACE ENVELOPES • Consult factory for dampers under 12" high. f Options Include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted intemally or extemally. 'A' Dimension Standard Minimum Sleeve Length With OCI, RRL, or TOR, H dimension less than 10" 1 » 10 /a 20 20" All other dampers 61/4" 16" CONFIGURATIONS CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille } f A 'X' L J Fire Rated Ceiling Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling 5" — / /J/ I/ / / / / / /// ��� \ \,, \ \�`� \` \� A Fire Rated Ceiling Grille (by others) Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Fire Rated Co ling 1 L 'H' H 4 Finished Coiling Below Grille (by others) 'H' 1 A 'A' A 5" 16" 'A' A Sleeve Length 4 Min. r v 'A' 1 Sleeve Length c SPACE ENVELOPES • Consult factory for dampers under 12" high. f Options Include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted intemally or extemally. SPECIFICATIONS Corridor Ceiling Fire Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans, and /or as described in schedules. Dampers shall be classified by UL under the "Corridor Damper" listing with a fire resistance rating of 1 hour and shall further carry a leakage Class I rating under UL 555S. Each damper /actuator combination shall have a UL555S elevated temperature rating of 350 °F minimum and shall be operational and dynamic rated to operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specifier select one of the following) electric type for 24 Vac or 120 Vac operation OR pneumatic type for 20 psi operation. • CFSD -23 Damper blades shall be 16 ga. galvanized steel 3 Vee type with three longitudinal grooves for reinforcement. Damper frame shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be sintered bronze sleeve type turning in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tight seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Each damper shall be supplied with a 165 °F fusible link. The basis of design is Greenheck Model CFSD -23. EPREENHECK PROJECT Corporate Square LOCATION Tukwila, WA CONTRACTOR Comfort Plus PRODUCTS Fan powered terminal units :: Air Commodities Inc. HEATING • VENTILATING • AIR CONDITIONING EQUIPMENT AIM Submittal Corporate Square EQUIPMENT PROVIDED Titus By: Matthew Rybar March 2, 1998 Mqq, oo� CITY OF MAR 2 0 1998 PERMIT CENTER 6100 Sixth Avenue South, Seattle WA 98108 • (206) 767 -2600 • Fax: (206) 767 -4815 • 1- 800.875.2473 www.air- commodities.com Unit Size Motor Horse- power Motor Amperage Ratings 120/1/60 208/240/1/60 277/1/60 FLA FLA FLA 2 ' /,o 2.6 1.1 0.8 3 V. 6.4 2.7 2.0 4 '/. 6.4 2.7 2.0 5 '/2 9.8 4.0 3.0 6 3 /4 18.0 7.5 5.6 TITUS® Submittal Terminal Units • Fan Powered • Parallel Type Model: PMFV • Pressure Independent • Pneumatic Controls D Dimensions are in inches. A Bsckdraft Damper Control Enclosure. (Omitted when electric coil is furnished.) L 1 —• -- • 12 —�� —� F Induced Air Access Panel (Entire Bottom is Removable) Primary «Air 71 113 3/8 E FLA = Full Load Amperage, as tested in accordance with UL 1995. All fan motors are single phase, same voltage as electric coil (when supplied), with exception that 277 voltage motors are used with 480 volt / 3 phase coil (4 wire wye). Finer (Optional) Metal Controller Cover (Optional) (Please see reverse side.) 1 FP- PMFV -1.0 5 -1 -95 Nominal Inlet Size Minus 1/8 Unit Size 2, 3 4, 5 6 Inlet Size 6 8 10 8 10 12 14 10 12 14 16 A 11 16 20 B 10 13 15 C 2 '/2 2 '/2 2 '/2 D 2 2 2 7 8 '/2 9 '/2 F 16'1. 18 '1. 20 '/ G 3 4 '/2 5 '/2 J 14 17 19 5 '/2 6 '/2 7 '/2 6 '/2 7 '/2 8'/2 9 '/2 7 '/2 8 '/2 9 '/2 10 'h K 12 15 17 M 31 32 34 '/t 20 25 '/2 25 '/2 N ifAiiiN Filter Size 1 '/2 1 '/2 39 1 /2 47 51 22 x 14 27 x 17 27 x 19 All dimensions are in inches. Filter size is for unit without attenuator For filter size with attenua or, please see reverse side. Accessories (Optional) Check rif if provided. p TITUS II Controller maintains constant reset span and start point, regardless of changes to HI and LO efm limits. 0 Induced air filter, 1" thick, disposable construction type. o Fan disconnect switch (not available on units with optional electric coils). RECEIVED CITY OF TUKWILA ❑ Metal controller cover. O Hanger brackets. ❑ Micro -LocTM Liner. MAR 2 0 1998 PERMIT CENTER FP -1.0 -S Unit Size AA BB CC Filter Size - 2, 3 21 12 12 (2) 12 10 4, 5 26 '/z 15 15 (2) 15 x 12 6 26 '/z 17 15 (2) 17 '/z x 12 Unit Size R• S• T 1 Row Coil 2 Row Coil X X 2, 3 19 _ 12 '/z z/. 2 3 4, 5 24 '/z 15 1 2 3 6 24 '/a 17 '/a a/. 2 3 Unit Size R• S• 2, 3 11 10 4, 5 16 13 6 20 15 Submittal FP- PMFV -1.0 5-1-L Accessories (Optional) Check if provided ❑ Hot Water Coil Section All dimensions are in inches. Standard Features • '/z copper tubes. • Aluminum ripple fins, 10 per inch. • Connections: Male solder, 1- row' /a ", 2 -row .". Right hand only. ❑ Electric Coil Section All dimensions are in inches. Standard Features • Automatic reset thermal cutouts, one per element. • Single point electrical connection for entire unit, including coil. • Positive pressure air flow switch. • Flanged duct connection. • Coil is installed at discharge of unit. General Description • Heavy steel casing, with leak resistant construction. • Dual density insulation, coated to prevent air erosion, meets requirements of NFPA 90A and UL 181. • Bottom access panel can be removed for service. TITUS® • Galvanized steel casing. • Flanged duct connection. • Coil is installed at induced air inlet. Note: Coil control box replaces stan- dard terminal unit control box. Options Check ® Selection ❑ Mercury contactors. ❑ Fuse block. ❑ Disconnect switch, door interlock type. ❑ Manual reset cutout. ❑ Dust tight construction. • Energy efficient fan motor, permanent split capacitor type, mounted in vibration isolators. • Adjustable SCR fan speed control, with minimum voltage stop. • Pressure independent primary air flow control. Primary Alr L,J Coil Rows ❑ 1 -Row ❑ 2 -Row 1 +- J 6 11/4 •" I/2 1 — IT L1' Alr s • Flow Dis- t charge Alr S Flow t —.4-4 R L t —.�1 9' max L Check d if provided. • Note: R and S are inside dimensions. • Note: R and S are inside dimensions. Supply Voltage Check ® Selection 0208 V, 1 ph, 60 Hz. 0240 V, 1 ph, 60 Hz. 0277 V, 1 ph, 60 Hz. 0208 V, 3 ph, 60 Hz. 0480 V, 3 ph, 60 Hz (4 wire wye). ❑ Induced Air Inlet Attenuator All dimensions are in inches. ae Lcc_J • Multipoint inlet velocity sensor with center averaging. • Primary air flow balancing connections. • Single point electrical connectionIREG V TUI(WILA • Rectangular discharge openil's designed for flanged duct connections. MAR 2 0 1998 Pambu G 1 tzN Note: This submittal is meant to demonstrate general dimensions of this product The drawing on this submittal are not meant to detail every aspect of the product with exactness. Drawings are not 10 scale. TITUS reserves the not to make changes wmhout written notice. 990 Security Row • Richardson, Texas 75081 •214.699.1030 • Fax 214-644-4953 Al ny,r ~rod mo C•n or tna .or• may be n•r•ood or raun+•a n wry No r • y mom ormirorra r ralarmarral. marina pWmry•W .,W woaarq 44 W •rM wrrrn..a, Maio , w..val warren wane varn•M rn n .,arm Yen Team. Uoluor,.a No. Unit Size Motor Horse- power Motor Amperage Ratings 120/1/60 208/24W1/60 277/1/60 FLA FLA FLA 2 ' /I. 2.6 1.1 i 0.8 3 V. 6.4 2.7 2.0 4 '1. 6.4 2.7 2.0 5 '/3 9.8 4.0 3.0 6 V. 18.0 7.5 5.6 TITUS® Submittal Terminal Units • Fan Powered • Parallel Type Model: AMFV • Pressure Independent • Analog Electronic Controls Unit Size 2, 3 4, 5 6 Inlet Size 6 8 10 8 10 12 14 10 12 14 16 oJ� Dimensions are in inches I I 6 C } 26(WIthout Electric Coil) 18(With Electric Coil) 11 16 20 10 13 15 Backdraft Damper 2 'h 2 '/2 2 '/a 2 w 7 8 '/a 9 '/a F 5 '1. 5 V. 7 '/. 5 '/A 7 '/. 7 1. 99'/2 7 '/A 7 V. 9 '/A 99/. Induced Air Filter (Optional) Primary Air M J Access Panel (Entire Bottom 1s Removeabie) 4 '/a 5 '/2 J 5 '/a 14 6 '/a 7 '/a 17 19 (Please see reverse side.) 6 'h 7 '/a 8 '/a 9 '/a 7 '/3 88' /a 9 '/3 10 '/, FLA = Full Load Amperage, as tested in accordance with UL 1995. At fan motors are single phase, same voltage as electric coil (when supplied), with exception that 277 voltage motors are used with 480 volt / 3 phase coil (4 wire wye). 12 15 17 Man 31 32 34 '/a All dimensions are in inches. Filter size is for unit without attenuator For fitter size with attenua or, please see reverse side. 20 25 '/a 25 '/a 1 FP- AMFV -1.0 10 -1 -95 Nominal Inlet Size Minus 1/8 1 'h wag 39 '/a 47 51 Filter Size 22 x 14 27 x 17 27 x 19 Accessories (Optional) Check [.7f if provided. ❑ Induced air filter, 1' thick, disposable con- struction type. ❑ Fan Unit Fusing ❑ Fan disconnect switch (not available on units with optional electric coils). ❑ Micro-Loon' Insulation. ❑ Hanger Brackets. RECEIVED CITY OF TUKWIIA RAR 2 0 1998 PERMIT CENTER FP -9.0 -S Unit Size AA 8B CC Filter Size 2, 3 21 12 12 (2) 12 '/a x 10 4, 5 26 '/2 15 15 (2) 15 x 12 6 26 '/2 17 15 (2) 17 '/2 x 12 Unit Size R• S• T 1 Row Coil 2 Row Coil X X 2, 3 19 112 '/: Y. 2 3 4, 5 24 /2 I 15 1 2 3 6 24 '/2117 72 2 /. 2 3 Unit Size R• S• 2, 3 11 10 4, 5 16 13 6 20 15 Submittal FP- AMFV -1.0 Accessories (Optional) ❑ Induced Air Inlet Attenuator All dimensions are in inches. General Description • Heavy steel casing, with leak resistant construction. • Dual density insulation, coated to prevent air erosion, meets requirements of NFPA 90A and UL 181. • Bottom access panel can be removed for service. • Energy efficient fan motor, permanent split capacitor type, mounted in vibration isolators. TITUS® 10 -1 -95 Check ® if provided ❑ Hot Water Coil Section All dimensions are in inches. Standard Features • ' /t" copper tubes. • Aluminum ripple fins, 10 per inch. • Connections: Male solder, 1-row '/2 ", 2 -row ' /.'. Right hand only. • Galvanized steel casing. • Flanged duct connection. • Coil is installed at induced air inlet. Coil Rows Check [a ' if provided. ❑ 1 -Row ❑ 2 -Row • Note: R and S are inside dimensions. ❑ Electric Coil Section All dimensions are in inches. Standard Features • Automatic reset thermal cutouts, one per element • Single point electrical connection for entire unit, Including coll. • Positive pressure air flow switch. • Flanged duct connection. • Coil is installed at discharge of unit. Note: Coil control box replaces standard ter- minal unit control box. Options Check 0 Selection ❑ Mercury contactors. ❑ Fuse block. ❑ Disconnect switch, door interlock type. ❑ Manual reset cutout. ❑ Dust tight construction. e R —+7 2 1 h F-.. t Dis• t:h.rg. Air s' Flow Supply Voltage Check ® Selection 0208 V, 1 ph, 60 Hz. 0240 V, 1 ph, 60 Hz. 0277 V, 1 ph, 60 Hz. 0208 V, 3 ph, 60 Hz. 0480 V, 3 ph, 60 Hz (4 wire wye). ' Note: R and S are inside dimensions. • Adjustable SCR fan speed control, with minimum voltage stop. • Pressure independent primary air flow control. • Electronic proportional room thermostat with adjustable temperature setpoint is Included with unit. • Minimum and maximum air flow adjustments are made at the room thermostat, using a digital voltmeter. • Single point electrical connections. • Rectangular discharge opening is designed for flanged duct connections. AECET UK°NILA CIT( �F MAR 2 0 199 Mote: This submittal is meant to demonstrate general dimensions of this product. The drawing on this submittal are not meant to detail every aspect of the ptoduct with exactness. Drawings are not to sale. TITUS reserves the right to make changes without written notice. 990 Security Row • Richardson, Texas 75081 • 214-699-1030 • Fax 214- 644 -4953 M VIII r•oonW No art or tau soft envy W rwo••w•d w ewrMrrd n We 4rrr ef e+r .,— m. orrew w „toms•!. ••llirer9 Ywagwe voila owwrw w a •r7 rdemomm amp we,* Ina.. rot w •••r 5._ Tyler. YNr•eIN. K OM s^^ TITUS® Models: PMFV, AMFV, DMFV • Fan Performance vs. Downstream Static Pressure • Induction Side 600 550 500 450 400 350 u. 300 250 200 150 100 50 0 2000 1800 1600 1400 1200 u 1000 800 600 400 200 Unit Size 2 ItAIIIIN■1111E ICia_•1M■■■ IVIMERIMI IFIIIIIIIMMI 0.0 0.1 0.2 0.3 0.4 0.5 06 Static Pressure - Inches of Water Unit Size 5 z. 3 5 0 CD ni cc 'v R i . MAX ti MIN 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 Static Pressure • Inches of Water Fan Powered Terminals > Performance Oata 41I V 800 750 700 650 600 u. 550 500 450 400 350 300 00 01 02 03 04 05 06 Static Pressure - Inches of Water 2200 2100 2000 1900 1800 1700 LL 1600 1500 1400 1300 1200 No Coil or Electric Coil 1 Row Water Coil 2 Row Water Coil Unit Size 3 0 Unit Size 6 1100 0.0 0.1 0.2 0.3 0.4 05 06 Static Pressure • Inches of Water 1400 1300 1200 1100 1000 u- 900 V 800 700 600 500 400 Unit Size 4 3 00 01 02 03 04 05 06 Static Pressure - Inches of Water T/ RECEI � wI1.A MAR 2 0 1998 PERMIT CENTER 2 -3 4-5 6 10 600 - • • 23 30 21 25 27 800 • 20 - 20 21 25 29 31 1000 • • 22 24 24 28 32 34 1200 • 21 25 28 27 31 34 37 1400 20 24 28 30 29 33 37 39 6 16 1600 • • 20 23 30 34 38 41 2000 • 20 24 27 33 37 42 44 2600 20 25 29 32 37 41 45 47 3200 24 28 33 35 40 44 48 50 4000 28 32 37 39 43 47 51 53 2.3 4 -5 8 350 • • • - • - • 21 400 • - 20 22 25 29 20 23 500 • - 24 26 29 33 23 26 700 20 24 21 23 20 24 28 30 800 22 26 23 26 22 26 30 32 4.5.6 12 900 2 - - 20 23 27 31 33 1100 • - 20 22 25 29 33 36 1400 • 20 24 26 29 33 37 39 1800 20 24 28 31 32 36 40 42 2000 22 26 30 33 33 37 41 43 4-5-6 14 1200 2 - - 20 27 31 35 37 1600 • • 23 25 30 35 39 41 2000 • 22 27 29 33 37 42 44 2400 22 26 30 32 36 40 44 46 3000 25 30 34 36 39 43 47 49 2 -3 6 225 2 - - cfm 6 Discharge Environ. Effect • 300 - - A Ps 1 Ceiling Effect A Ps 10 20 400 - - 1.0" 1 2.0" 1 3.0" • 11 21 24 450 - 21 22 21 - - 23 25 500 10 11 21 23 14 20 24 27 Sound Noise Criteria NC) Octave Bands 2 Unit Size Inlet Size cfm 6 Discharge Environ. Effect 3 Radiated 1 1 A Ps 1 Ceiling Effect A Ps 10 0.5•' 1 1.0•' 2.0" 1 3.0" 0.5" 1.0" 1 2.0" 1 3.0" S42 TITUS® Irrit H h , Models: PMFV, AMFV, DMFV • Application Data • NC Values 100% Primary Air • Ps is the difference in static pressure from inlet to discharge. > Dash (•) in space denotes NC value less than 20. • All sound data are based upon tests conducted in accordance with ARI 880-94. Application data are based upon factors found in ARI Standard 885-90: • Ceiling type - mineral fiber, 5/8 In. -35 lb./ cu. ft. Room size • 3.000 cu. It., 10 ft. from the source Application data are based upon factors found in ARI Standard 885.90: • End reflection • 8 in. termination > Flex type • vinyl core flex 5 ft. of 1 in. thick duct lining > Room size • 3,000 cu. ft., 10 ft. from the source • For complete information on calculation of NC levels, refer to catalog pages C65 -C77. The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction IdB) 0 3 6 8 10 11 u itt 19.16 p5U Radiated Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 Ceiling Effect 9 10 12 14 15 15 Room Effect 9 10 11 12 13 14 Total dB reduction 21 22 24 27 29 30 S42 TITUS® Irrit H h , Models: PMFV, AMFV, DMFV • Application Data • NC Values 100% Primary Air • Ps is the difference in static pressure from inlet to discharge. > Dash (•) in space denotes NC value less than 20. • All sound data are based upon tests conducted in accordance with ARI 880-94. Application data are based upon factors found in ARI Standard 885-90: • Ceiling type - mineral fiber, 5/8 In. -35 lb./ cu. ft. Room size • 3.000 cu. It., 10 ft. from the source Application data are based upon factors found in ARI Standard 885.90: • End reflection • 8 in. termination > Flex type • vinyl core flex 5 ft. of 1 in. thick duct lining > Room size • 3,000 cu. ft., 10 ft. from the source • For complete information on calculation of NC levels, refer to catalog pages C65 -C77. The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction IdB) 0 3 6 8 10 11 u itt 19.16 p5U Dlscharge Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 End Reflection 11 6 2 0 0 0 Duct Lining 1 3 8 21 20 12 5'. 8" Flex Duct 6 10 17 19 19 12 Room Effect 9 10 11 12 13 14 Total dB reduction 30 31 39 53 53 39 S42 TITUS® Irrit H h , Models: PMFV, AMFV, DMFV • Application Data • NC Values 100% Primary Air • Ps is the difference in static pressure from inlet to discharge. > Dash (•) in space denotes NC value less than 20. • All sound data are based upon tests conducted in accordance with ARI 880-94. Application data are based upon factors found in ARI Standard 885-90: • Ceiling type - mineral fiber, 5/8 In. -35 lb./ cu. ft. Room size • 3.000 cu. It., 10 ft. from the source Application data are based upon factors found in ARI Standard 885.90: • End reflection • 8 in. termination > Flex type • vinyl core flex 5 ft. of 1 in. thick duct lining > Room size • 3,000 cu. ft., 10 ft. from the source • For complete information on calculation of NC levels, refer to catalog pages C65 -C77. The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction IdB) 0 3 6 8 10 11 u itt 19.16 p5U 3 475 28 - 500 29 - 525 29 - 550 30 - 600 31 - 650 32 - 4 600 31 - 700 32 - 800 33 - 900 33 - 1000 34 - 1150 35 - 2 300 28 - 350 30 - 400 31 - 450 32 - 500 33 - 520 33 - 6 1250 34 - 1350 35 - 1500 36 - 1650 37 - 1800 39 - 2100 41 21 5 800 30 - 900 32 - 1100 35 - 1300 37 - 1500 39 • 1800 42 21 TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals Y Performance Data a 1946 0 ,56 1996 Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in.-35 lb./ cu. ft. • Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 in. thick duct lining Room size - 3,000 cu. It.. 10 ft. from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. All sound data are based upon tests conducted In accordance with ARI 880-94. For complete information on calculation of NC levels, refer to catalog pages C65 -C77. CI'N OF T KNI14A NiAR 2 p 1998 pe p M t1' C B1 \ 1 1T 1 S43 E 03 0 0, Fan NC Levels Size cfm Rad. Disc. 6 7. NC NC TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals Y Performance Data a 1946 0 ,56 1996 Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in.-35 lb./ cu. ft. • Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 in. thick duct lining Room size - 3,000 cu. It.. 10 ft. from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. All sound data are based upon tests conducted In accordance with ARI 880-94. For complete information on calculation of NC levels, refer to catalog pages C65 -C77. CI'N OF T KNI14A NiAR 2 p 1998 pe p M t1' C B1 \ 1 1T 1 S43 E 03 0 0, Radiated Attenuation Values - Octave Bands 2 3 4 5 6 7. Environ. Effect 3 2 1 1 1 1 Ceiling Effect 9 10 12 14 15 15 Room Effect 9 10 11 12 13 14 Total dB reduction 21 22 24 27 29 30 TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals Y Performance Data a 1946 0 ,56 1996 Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in.-35 lb./ cu. ft. • Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 in. thick duct lining Room size - 3,000 cu. It.. 10 ft. from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. All sound data are based upon tests conducted In accordance with ARI 880-94. For complete information on calculation of NC levels, refer to catalog pages C65 -C77. CI'N OF T KNI14A NiAR 2 p 1998 pe p M t1' C B1 \ 1 1T 1 S43 E 03 0 0, Discharge Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 End Reflection 11 6 2 0 0 0 Duct Lining 1 3 8 21 20 12 5 ', 8" Flex Duct 6 10 17 19 19 12 Room Effect 9 10 11 12 13 14 Total dB reduction 30 31 39 53 ` 53 39 TITUS® Models: PMFV, AMFV, DMFV • Application Data • NC Values (Fan Only) Fan Powered Terminals Y Performance Data a 1946 0 ,56 1996 Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in.-35 lb./ cu. ft. • Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 in. thick duct lining Room size - 3,000 cu. It.. 10 ft. from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. All sound data are based upon tests conducted In accordance with ARI 880-94. For complete information on calculation of NC levels, refer to catalog pages C65 -C77. CI'N OF T KNI14A NiAR 2 p 1998 pe p M t1' C B1 \ 1 1T 1 S43 E 03 0 0, 2.3 4-5 8 350 0.040 54 55 58 61 63 46 48 50 54 56 41 42 45 49 50 36 38 40 44 45 27 28 30 34 35 23 25 26 29 30 57 58 61 64 66 50 51 54 57 59 44 46 48 52 53 39 41 43 47 48 30 31 34 37 38 26 27 29 32 33 60 61 64 68 69 53 55 57 61 62 47 49 51 55 57 43 44 46 50 51 33 35 37 40 41 28 30 31 34 36 62 63 66 69 71 55 57 59 63 64 49 51 53 57 59 44 46 48 52 53 35 37 39 42 43 30 31 33 36 37 400 0.052 500 0.081 700 0.158 800 0.207 6 16 1600 0.029 67 70 73 75 77 64 66 69 72 74 53 56 59 61 64 46 48 51 53 56 41 43 45 47 49 37 39 41 43 44 71 73 76 78 80 67 70 73 75 78 57 59 62 65 67 49 51 54 56 59 44 46 48 50 52 39 41 43 45 47 74 76 79 81 84 71 73 76 79 81 60 63 66 68 70 52 54 57 59 62 47 49 51 53 55 42 44 46 48 49 76 78 81 83 86 73 75 78 81 83 62 65 67 70 72 54 56 59 61 64 49 51 53 55 57 43 45 47 49 51 2000 0.045 2600 0.076 3200 0.115 4000 0.180 4 -5 6 12 900 0.035 62 64 67 69 70 57 60 62 65 66 49 51 54 57 58 43 45 47 50 51 36 37 40 42 43 32 33 35 38 38 65 67 70 73 74 61 63 66 68 69 52 54 57 60 61 46 48 50 53 54 39 41 43 45 46 34 36 38 40 41 69 71 73 76 77 64 66 69 72 73 55 58 60 63 64 49 51 53 56 57 42 44 46 48 49 37 38 40 43 43 71 73 75 78 79 66 68 71 74 75 57 60 62 65 66 51 53 55 58 59 44 46 48 50 51 38 40 42 44 45 1100 0.053 1400 0.085 1800 0.141 2000 0.174 2-3 4.5 6 10 600 0.038 59 62 64 66 67 53 56 59 61 62 46 49 51 53 55 40 43 45 47 49 32 35 37 39 40 28 31 32 34 35 62 65 67 69 71 56 59 62 64 66 49 52 55 57 58 43 46 48 50 52 35 38 40 42 43 31 33 35 36 38 65 68 70 72 74 59 63 65 67 69 52 55 58 60 62 46 49 51 53 55 38 41 43 45 46 33 36 37 39 40 67 70 72 74 76 61 64 67 69 71 54 57 60 62 64 48 51 53 55 57 40 43 45 47 48 35 37 39 40 42 800 0.068 1000 0.107 1200 0.154 1400 0.209 4 -5 6 14 1200 0.029 64 68 70 72 74 61 64 66 68 71 51 54 57 59 61 45 48 51 52 55 38 41 43 44 46 34 37 39 40 42 68 71 73 75 78 64 67 70 72 74 54 58 60 62 65 48 51 53 55 57 41 44 46 48 50 37 39 41 43 45 71 74 77 79 81 68 71 73 75 78 58 61 63 65 68 50 53 56 57 60 45 47 49 51 53 39 42 44 45 47 73 76 79 81 83 70 73 75 77 80 60 63 65 67 70 52 55 57 59 61 47 49 51 53 55 41 43 45 47 49 1600 0.052 2000 0.081 2400 0.117 3000 0.183 2 -3 6 225 0.064 49 52 56 57 58 41 44 47 49 50 38 41 45 46 47 35 38 41 42 43 23 26 29 30 31 19 22 24 25 26 53 56 59 60 61 44 48 51 52 53 41 45 48 49 50 38 41 44 45 46 26 29 32 33 34 22 24 27 28 29 56 59 62 64 65 48 51 54 56 57 44 48 51 52 53 41 44 47 48 49 30 32 35 36 37 24 27 29 31 31 58 61 64 66 67 50 53 56 58 59 46 50 53 54 55' 42 45 49 50 51 32 34 37 38 39 26 28 31 32 33 300 0.114 400 0.202 450 0.256 500 0.316 Inlet Pr!. Min. Sound Powe @ 1.5" A P Size cfm 1 Ps 2 3 4 5 6 7 6 400 0.200 61 59 50 46 34 28 8 700 0.160 66 66 54 49 39 33 10 1100 0.130 70 72 58 51 43 37 12 1600 0.140 73 77 60 54 46 41 14 2100 0.120 76 80 63 55 48 43 16 2800 0.200 79 85 65 57 51 45 Unit Size Inlet Size cfm MIn. A P Primary Air - Sound Power Octave Bands 0.5 "A Ps 1.0 "A P 2.0 ".1 P 3.0 "A P. 2 5 1 617 2131415 617 21314 51617 21 31_ 4151 6 ,1 7 S44 TITUS® ARI Certification Rating Points Fan Powered Terminals > Performance Bala S O 19 4F . 0 1 1 Models: PMFV, AMFV, DMFV • Radiated Sound Power Levels • 100% Primary Air Min. A P is the lowest static pressure difference (damper wide open). > Radiated sound power is the noise transmitted through the casing walls, > Sound power levels are in decibels. re 10 "watts. All sound data are based upon tests conducted in accordance with ARI 880.94, Note: Ratings in accordance with ARI Standard 880-94 and certified to ARI. A Participating Corporation in the ARI 880 Certification Program RRO►��KW11A CI' /OF NIAR 2 0 1998 6 16 1600 0.029 69 68 68 61 60 55 72 72 71 64 63 58 76 75 74 67 66 60 78 77 76 69 68 62 2000 0.045 72 71 71 64 62 57 76 75 74 67 65 60 79 79 77 70 68 63 81 81 79 72 70 65 2600 0.076 76 75 74 68 65 60 80 79 77 71 68 63 83 83 81 74 71 66 85 85 82 76 73 68 3200 0.115 79 78 77 71 67 63 83 82 80 74 70 66 86 86 83 77 73 69 88 88 85 79 75 70 4000 0.180 83 82 79 74 69 65 86 85 83 77 72 68 89 89 86 80 75 71 91 91 88 82 77 73 .4 -5 6 14 1200 0.029 66 65 63 58 56 51 69 68 67 61 60 54 73 72 70 64 63 57 75 74 72 66 65 58 1600 0.052 70 69 67 62 59 55 73 73 71 65 62 57 77 76 74 68 66 60 79 78 76 70 68 62 2000 0.081 73 73 70 65 61 57 76 76 73 68 65 60 80 80 77 71 68 63 82 82 79 73 70 64 2400 0.117 75 75 72 68 63 59 79 79 76 71 67 62 82 82 79 74 70 65 84 84 81 76 72 66 3000 0.183 78 79 75 71 66 62 82 82 79 74 69 65 85 86 82 77 72 67 87 88 84 79 74 69 4-5 6 1 2 900 0.035 62 61 59 55 52 47 65 65 62 58 55 50 69 69 66 61 58 53 71 71 68 63 60 54 1100 0.053 65 64 61 58 54 49 68 68 65 61 57 52 72 72 69 64 60 55 74 74 71 66 62 57 1400 0.085 68 68 65 6 1 56 52 72 72 68 64 60 55 75 75 72 67 63 58 77 7 7 74 69 65 59 1800 0.141 72 72 68 65 59 55 75 75 72 68 63 58 79 79 75 71 66 61 81 81 77 73 68 62 2000 0.174 73 73 69 66 60 56 77 77 73 69 64 59 80 81 77 72 67 62 82 83 79 74 69 64 2 -3 6 225 0.064 43 45 40 39 34 28 47 49 43 43 37 31 51 53 46 46 40 33 53 55 48 48 42 35 300 0.114 47 50 44 44 37 31 51 53 47 47 40 34 55 57 50 50 43 37 57 59 52 52 45 38 400 0.202 51 54 48 48 40 35 55 58 51 51 43 37 59 61 54 55 46 40 61 63 56 57 48 42 450 0.256 53 56 49 49 41 36 57 59 52 53 44 39 60 63 56 56 47 41 62 65 58 58 49 43 500 0.316 55 57 51 51 42 37 58 61 54 54 45 40 62 64 57 58 48 43 64 67 59 60 50 44 2-3 4-5 6 10 600 0.038 57 57 53 49 47 41 60 60 57 53 50 44 63 64 60 57 53 47 65 66 62 59 55 49 800 0.068 61 61 57 54 50 44 64 65 61 57 53 47 67 68 64 61 56 50 69 70 66 63 58 52 1000 0.107 64 64 60 57 52 47 67 68 64 60 55 50 71 72 67 64 58 53 72 74 69 66 60 55 1200 0.154 67 67 63 59 54 49 70 71 66 63 57 52 73 74 70 67 60 55 75 76 72 69 62 57 1400 0.209 69 70 65 62 55 51 72 73 68 65 59 54 75 77 72 69 62 57 77 79 74 71 64 59 2-3 4 -5 8 350 0.040 49 50 45 44 40 34 53 54 49 47 43 37 56 57 52 51 46 40 58 59 55 52 48 42 400 0.052 51 52 47 46 41 36 55 56 51 49 44 39 58 59 54 52 47 42 60 61 56 54 49 43 500 0.081 54 56 50 49 44 38 58 59 54 52 47 41 61 63 57 56 50 44 63 65 59 58 52 46 700 0.158 59 61 55 54 47 42 62 64 58 57 50 45 66 68 62 60 54 48 68 70 64 62 55 50 800 0.207 61 63 57 56 49 44 64 66 60 59 52 47 68 70 64 62 55 50 70 72 166 64 57 51 Inlet Pri. Min. Sound Powe @ 1.5" a P Size cfm A Ps 2 3 4 5 6 7 6 400 0.200 57 67 58 53 45 39 8 700 0.160 64 74 66 59 52 47 10 1100 0.130 71 80 73 67 58 53 12 1600 0.140 76 85 79 68 63 58 14 2100 0.120 79 88 83 71 67 62 16 2800 0.200 83 92 88 74 70 66 Unit Size Inlet Size cfm Min. 1 Ps Primary Air • Sound Power Octave Bands 0.5"..1 P5 1.0 "1 P 2.0 "1 Ps 3.0" 1 P 2 3 4 5 1 6 7 2 1 3 4 1 5 6 7 2 3 4 5 6 7 2 3 4 5 1 6 7 TITUS® Models: PMFV, AMFV, DMFV • Discharge Sound Power Levels • 100% Primary Air ARI Certification Rating Points Fan Power d`Terminals > Performance Data 4 U 1946 c o 199f 9f i • Min. A P is the lowest static pressure difference (damper wide open'. Discharge sound power is the noise emitted from the unit discharge Into the downstream duct, • Sound power levels are in decibels. re 10' watts > All sound data are based upon tests conducted in accordance with ARI 880.94. Note: Ratings in accordance with ARI Standard 880.94 and certified to ARI. A Participating Corporation in the ARI 880 Certification Program S4; 2 300 0.25 63 57 58 50 43 39 52 54 52 51 42 33 350 0.25 64 58 59 51 45 41 54 55 53 52 43 35 400 0.25 65 59 60 52 47 42 55 56 54 53 44 37 450 0.25 66 60 61 53 48 44 56 57 55 54 45 38 500 0.25 67 60 62 54 50 45 57 58 56 54 46 40 520 0.25 67 61 63 55 50 46 58 59 57 54 47 40 3 475 0.25 66 62 58 50 45 41 60 63 58 54 52 44 500 0.25 66 62 58 51 46 42 61 63 59 55 53 45 525 0.25 67 63 59 51 46 43 62 64 60 56 53 46 550 0.25 67 63 59 52 47 44 63 64 60 56 54 47 600 0.25 67 64 60 53 48 46 64 65 62 57 56 48 650 0.25 68 64 61 54 50 48 65 66 63 58 57 50 4 600 0.25 66 64 61 53 50 45 60 55 57 51 47 41 700 0.25 67 64 61 54 52 48 61 56 58 53 49 43 800 0.25 67 64 62 55 54 50 62 57 59 55 51 45 900 0.25 68 64 62 56 55 52 63 58 60 56 52 47 1000 0.25 68 65 63 57 57 53 64 59 60 57 53 49 1150 0.25 69 65 64 58 59 55 65 60 61 58 55 51 5 800 0.25 66 61 60 54 51 46 61 56 57 53 48 41 900 0.25 67 62 61 55 53 48 63 58 60 55 51 44 1100 0.25 69 65 64 58 56 52 66 62 63 59 55 49 1300 0.25 71 67 66 60 59 56 69 65 66 62 59 53 1500 0.25 72 69 68 62 61 58 71 68 69 65 62 56 1800 0.25 74 71 70 64 64 62 74 71 72 68 66 60 6 1250 0.25 68 66 63 58 57 52 66 64 64 60 59 52 1350 0.25 69 67 64 59 58 54 68 65 65 61 60 53 1500 0.25 70 68 65 60 59 56 69 66 67 63 61 55 1650 0.25 71 69 66 61 61 58 71 68 69 65 63 57 1800 0.25 72 70 67 62 62 59 72 69 70 66 64 59 2100 0.25 74 71 69 63 64 62 74 72 73 69 67 62 Unit Size Fan cfm Outlet AP Unit Size Radiated Sound Power Fan cfm Fan Only Discharge Sound Power Octave Bands 2 3 Octave Bands 5 2 3 4 5 6 7 2 3 4 5 6 7 E G- 00 S46 TITUS Models: PMFV, AMFV, DMFV • Sound Power Levels • Fan Only • Heating Cycle ARI Certification Rating Points Fan Powered Terminals > Performance Data 1946 0,5� 1996 > Outlet _P, is the difference in static pressure from the terminal discharge to the room. > Radiated sound power is the noise transmitted through the casing walls. p > Discharge sound power is the noise emitted from the unit discharge into the downstream a �UK`N lit MI CI ‘rmi A Participating 90:4 ce Ce I adon Program Sound power levels are in decibels, re 10'' watts. All sound data are based upon tests conducted in accordance with ARI 880-94. Note: Ratings in accordance with ARI Standard 880.94 and certified to ARI. Radiated Sound Power Discharge Sound Power Unit Size Fan watts Fan cfm Fan Only Fan Only 2 3 4 5 6 7 2 3 4 5 6 7 2 175 400 70 64 66 58 53 49 61 62 60 57 52 49 3 375 680 73 69 68 61 57 57 73 73 70 65 65 62 4 450 950 72 68 67 62 62 59 68 64 65 62 59 55 5 900 1380 77 74 75 71 69 63 77 74 75 71 69 63 6 1000 1610 77 74 72 66 67 65 77 75 76 72 70 65 E G- 00 S46 TITUS Models: PMFV, AMFV, DMFV • Sound Power Levels • Fan Only • Heating Cycle ARI Certification Rating Points Fan Powered Terminals > Performance Data 1946 0,5� 1996 > Outlet _P, is the difference in static pressure from the terminal discharge to the room. > Radiated sound power is the noise transmitted through the casing walls. p > Discharge sound power is the noise emitted from the unit discharge into the downstream a �UK`N lit MI CI ‘rmi A Participating 90:4 ce Ce I adon Program Sound power levels are in decibels, re 10'' watts. All sound data are based upon tests conducted in accordance with ARI 880-94. Note: Ratings in accordance with ARI Standard 880.94 and certified to ARI. Trane Air Conditioning Economics By: Comfort Plus ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** ** ** TRACE 600 ANALYSIS ** ** ** ** by Comfort Plus ** ** ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CORPORATE SQUARE BLDG 5 TUKWILA, WA LOAD DESIGN - 1 Weather File Code: Location: Latitude: Longitude: Time Zone: Elevation: Barometric Pressure: Summer Clearness Number: Winter Clearness Number: Summer Design Dry Bulb: Summer Design Wet Bulb: Winter Design Dry Bulb: Sumner Ground Relectance: Winter Ground Relectance: Air Density: Air Specific Heat: Density - Specific Heat Prod: Latent Heat Factor: Enthalpy Factor: SEATTLE SEATTLE, WA 47.0 (deg) 122.0 (deg) 8 386 (ft) 29.5 (in. Hg) 0.95 0.95 82 (F) 66 (F) 24 (F) 0.20 0.20 0.0749 (Lbm /cuft) 0.2444 (Btu /lbm /F) 1.0988 (Btu - min. /hr /cuft /F) 4,836.9 (Btu- min. /hr /cuft) 4.4953 (Lb- min. /hr /cuft) Design Simulation Period: June To November System Simulation Period: January To December Cooling Load Methodology: TETD /Time Averaging Time /Date Program was Run: 21:51:40 2/26/98 Dataset Name: CORP5 .EZT V 600 PAGE 1 CITY RECEIVED MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus AIRFLOW - ALTERNATIVE 1 System System Number Type Outside Airflow (Cfm) 1 VTCV 4,165 Totals 4,165 CAPACITY - ALTERNATIVE 1 1 VTCV Totals ENGINEERING CHECKS - ALTERNATIVE 1 System Main/ System Number Auxiliary Type 1 Main VTCV SYSTEM SUMMARY (Design Airflow Quantities) Main Auxil. Room Cooling Heating Return Exhaust Supply Exhaust Airflow Airflow Airflow Airflow Airflow Airflow (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) 25,089 25,089 25,089 4,165 0 0 25,089 25,089 25,089 4,165 0 0 SYSTEM SUMMARY (Design Capacity Quantities) Cooling Hain Sys. Aux. Sys. Opt. Vent Cooling Hain Sys. Aux. Sys. Preheat System System Capacity Capacity Capacity Totals Capacity Capacity Capacity Number Type (Tons) (Tons) (Tons) (Tons) (Btuh) (Btuh) (Btuh) ENGINEERING CHECKS Percent Outside Cfm/ Air Sq Ft 16.60 1.20 Heating The building peaked at hour 15 month 8 with a capacity of 40.9 tons Reheat Humidif. Opt. Vent Capacity Capacity Capacity (Btuh) (Btuh) (Btuh) Cooling - -- Heating - - -- Cfm/ Sq Ft Btuh/ Cfm/ Btuh/ Floor Area Ton /Ton Sq Ft Sq Ft Sq Ft Sq Ft 510.2 423.5 28.34 1.20 -22.98 20,824 V 600 PAGE 2 Heating Totals (Btuh) 49.2 0.0 0.0 49.2 - 478,616 0 0 0 0 0 - 478,616 49.2 0.0 0.0 49.2 - 478,616 0 0 0 0 0 - 478,616 RECEIVED CITY OF TUKWILA. MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus SYSTEM CHECKSUMS System Main Clg Aux Clg Opt Vent Totals 49.2 590.1 HEATING COIL SELECTION Capacity Coil Airfl Ent Lvg (Mbh) (cfm) Deg F Deg F Main Htg -478.6 25,089 60.2 77.6 Aux Htg 0.0 0 0.0 0.0 Preheat -0.0 25,089 60.2 56.0 Reheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -478.6 1 Peak VTCV COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airfl Entering DB /WB /HR (Tons) (Mbh) (Mbh) (cfm) Deg F Deg F Grains 49.2 590.1 521.4 25,089 75.2 61.6 61.4 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 AIRFLOWS (cfm) Type Cooling Heating Vent 4,165 4,165 Infil 0 0 Supply 25,089 25,089 Hincfm 0 0 Return 25,089 25,089 Exhaust 4,165 4,165 Rm Exh 0 0 Auxil 0 0 - VARIABLE TEMP CONSTANT VOL * * * * * * * * * * * * * * * * * * * * * * * ** COOLING COIL PEAK * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CLG SPACE PEAK * * * * * * * * * * ** HEATING COIL PEAK * * * * * * ** Peaked at Time = => Mo /Hr: 8/15 * Mo /Hr: 7/16 * Mo /Hr: 13/ 1 Outside Air =_> OADB /WB /HR: 78/ 64/ 70.0 * OADB: 79 * OADB: 24 * * Space Ret. Air Ret. Air Net Percnt * Space Percnt * Space Peak Coil Peak Percnt Sens. +Lat. Sensible Latent Total Of Tot * Sensible Of Tot * Space Sens Tot Sens Of Tot Envelope Loads (Btuh) (Btuh) (Btuh) (Btuh) ( %) * (Btuh) ( %) * (Btuh) (Btuh) ( %) Skylite Solr 0 0 0 0.00 * 0 0.00 * 0 0 0.00 Skylite Cond 0 0 0 0.00 * 0 0.00 * 0 0 0.00 Roof Cond 0 5,794 5,794 0.98 * 0 0.00 * 0 - 14,864 3.11 Glass Solar 284,640 0 284,640 48.24 * 298,536 56.99 * 0 0 0.00 Glass Cond -2,056 0 -2,056 -0.35 * -7,368 -1.41 * - 79,926 - 79,926 16.70 Wall Cond 654 235 888 0.15 * 281 0.05 * - 11,817 - 16,413 3.43 Partition 0 0 0.00 * 0 0.00 * 0 0 0.00 Exposed Floor 0 0 0.00 * 0 0.00 * 0 0 0.00 Infiltration 0 0 -0.00 * 0 -0.00 * -1 -1 0.00 Sub Total = => 283,238 6,028 289,266 49.02 * 291,449 55.64 * - 91,744 - 111,204 23.23 Internal Loads * * Lights 106,608 0 106,608 18.07 * 106,608 20.35 * 0 0 0.00 People 106,202 106,202 18.00 * 53,101 10.14 * 0 0 0.00 Misc 71,072 0 0 71,072 12.04 * 71,072 13.57 * 0 0 0.00 Sub Tota1= => 283,883 0 0 283,883 48.11 * 230,782 44.06 * 0 0 0.00 Ceiling Load 1,163 -1,163 0 0.00 * 1,571 0.30 * -3,758 0 0.00 Outside Air 0 0 0 17,730 3.00 * 0 0.00 * 0 - 201,360 42.07 Sup. Fan Heat 0 0.00 * 0.00 * 0 0.00 Ret. Fan Heat 0 0 0.00 * 0.00 * 0 0.00 Duct Heat Pkup 0 0 0.00 * 0.00 * 0 0.00 OV /UNDR Sizing 0 0 0.00 * 0 0.00 * - 168,658 - 168,658 35.24 Exhaust Heat -807 0 -807 -0.14 * 0.00 * 2,607 -0.54 Terminal Bypass 0 0 0 0.00 * 0.00 * 0 0.00 * * Grand Total = => 568,284 4,059 0 590,072 100.00 * 523,802 100.00 * - 264,160 - 478,616 100.00 Leaving DB /WB /HR Deg F Deg F Grains 56.0 53.5 57.9 0.0 0.0 0.0 0.0 0.0 0.0 -- ENGINEERING CHECKS- - Clg % OA 16.6 Clg Cfm /Sqft 1.20 Clg Cfm /Ton 510.23 Clg Sqft/Ton 423.49 Clg Btuh /Sqft 28.34 No. People 208 Htg % OA 16.6 Htg Cfm /SqFt 1.20 Htg Btuh /SqFt -22.98 V 600 PAGE 3 AREAS Gross Total Glass (sf) ( %) Floor 20,824 Part 0 ExFlr 0 Roof 11,408 Wall 10,584 0 0 3,096 29 -- TEMPERATURES (F) - -- Type Clg Htg SADB 56.0 77.6 Plenum 75.2 67.4 Return 75.2 67.4 Ret /OA 75.2 60.2 Runarnd 75.0 68.0 Fn HtrTD 0.0 0.0 Fn B1dTD 0.0 0.0 Fn Frict 0.0 0.0 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM COOLING - ALTERNATIVE 1 Peak OA Rm Supp. Time Cond. Dry Dry Room Mo /Hr DB /WB Blb Bulb Number Description (F) (F) (F) 1 9/10 66 59 75 56.0 2 7/ 9 67 57 75 56.0 3 7/ 9 67 57 75 56.0 4 7/ 9 67 57 75 56.0 5 7/ 9 67 57 75 56.0 6 6/19 69 55 75 56.0 7 7/17 78 61 75 56.0 8 7/17 78 61 75 56.0 9 7/17 78 61 75 56.0 10 7/15 80 64 75 56.0 11 lobby -1 10/13 64 55 75 56.0 Zone 1 Total /Ave. 79 63 75 56.0 Zone 1 Block 7/16 79 63 75 60.8 12 9/11 69 60 75 56.0 13 7/ 9 67 57 75 56.0 14 7/ 9 67 57 75 56.0 15 6/19 69 55 75 56.0 16 6/19 69 55 75 56.0 17 7/17 78 61 75 56.0 18 7/17 78 61 75 56.0 19 7/17 78 61 75 56.0 20 7/17 78 61 75 56.0 21 7/17 78 61 75 56.0 22 7/19 74 58 75 56.0 23 7/19 74 58 75 56.0 24 lobby -2 10/13 64 55 75 56.0 Zone 2 Total /Ave. 79 63 75 56.0 Zone 2 Block 7/16 79 63 75 60.4 System 1 Total /Ave. 79 63 75 56.0 System 1 Block 7/16 79 63 75 60.6 PEAK COOLING LOADS (Main System) Space Space Space Air Sens. Flow Load (Cfm) (Btuh) 1,609 946 453 1,553 553 578 1,100 428 1,877 1,334 1,413 11,842 11,842 1,226 2,675 676 235 727 522 1,109 538 588 1,212 2,223 103 1,413 13,247 13,247 25,089 25,089 33,583 19,751 9,452 32,413 11,552 12,057 22,962 8,931 39,193 27,850 29,495 247,239 184,686 25,600 55,845 14,110 4,906 15,184 10,889 23,152 11,226 12,283 25,308 46,417 2,142 29,501' 276,563 213,048 523,802 397,733 Space Peak OA Rm Supp. Coil Lat. Time Cond. Dry Dry Air Load Mo /Hr DB /WB Blb Bulb Flow (Btuh) (F) (F) (F) (Cfm) 2,285 9/10 66 59 75 56.0 1,958 8/ 9 67 59 75 56.1 245 8/ 9 67 59 75 56.1 2,938 8/ 9 67 59 75 56.1 1,224 8/ 9 67 59 75 56.4 1,408 7/14 79 65 75 56.5 979 7/17 78 61 75 56.0 653 7/17 78 61 75 56.0 2,040 7/17 78 61 75 56.0 6,365 7/14 79 65 75 56.0 3,917 8/13 76 64 75 57.6 24,011 78 64 75 56.3 24,011 8/15 78 64 75 61.0 1,836 9/14 75 62 75 56.9 3,182 8/ 9 67 59 75 56.1 1,306 8/ 9 67 59 75 56.1 816 7/14 79 65 75 56.2 2,122 7/14 79 65 75 56.4 816 7/16 79 63 75 56.5 1,142 7/17 78 61 75 56.0 490 7/17 78 61 75 56.0 734 7/17 78 61 75 56.0 1,632 7/17 78 61 75 56.0 10,608 7/14 79 65 75 56.0 490 7/14 79 65 75 56.0 3,917 8/13 76 64 75 57.7 29,090 78 64 75 56.3 29,090 8/15 78 64 75 60.6 53,101 78 64 75 56.3 53,101 8/15 78 64 75 60.8 V 600 PAGE 4 Coil Coil Coil Sens. Lat. Load Load (Btuh) (Btuh) 1,609 31,740 2,619 946 18,197 2,245 453 9,202 281 1,553 30,067 3,368 553 10,401 1,403 578 12,243 2,148 1,100 23,210 751 428 9,091 501 1,877 39,691 1,565 1,334 29,979 9,712 1,413 27,257 5,976 11,842 241,076 30,569 11,842 187,272 36,636 1,226 24,414 2,068 2,675 52,852 3,585 676 12,942 1,471 235 5,374 1,229 727 16,127 3,195 522 11,212 919 1,109 23,947 853 538 11,570 366 588 12,789 549 1,212 26,437 1,219 2,223 52,588 15,973 103 2,427 737 1,413 27,686 5,898 13,247 280,366 38,061 13,247 223,494 43,804 25,089 521,442 68,630 25,089 410,765 80,440 CITY OF MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM HEATING - ALTERNATIVE 1 Room Number Zone Zone 12 13 14 15 16 17 18 19 20 21 22 23 24 Zone Zone System System Floor Area Description (Sg Ft) 1 896 2 768 3 96 4 1,152 5 480 6 552 7 384 8 256 9 800 10 2,496 11 lobby -1 1,536 1 Total /Ave. 9,416 1 Block 9,416 720 1,248 512 320 832 320 448 192 288 640 4,160 192 lobby -2 1,536 2 Total /Ave. 11,408 2 Block 11,408 1 Total /Ave. 20,824 1 Block 20,824 Peak Time Mo /Hr 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 24 13/ 1 24 PEAK HEATING (Main System) 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Space OA Rm Supp. Cond. Dry Dry DB /WB Blb Bulb (F) (F) (F) 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 77.6 77.6 Space Air Flow (Cfm) 1,609 946 453 1,553 553 578 1,100 428 1,877 1,334 1,413 11,842 11,842 1,226 2,675 676 235 727 522 1,109 538 588 1,212 2,223 103 1,413 13,247 13,247 25,089 25,089 LOADS Space Peak OA Rm Supp. Sens. Time Cond. Dry Dry Load Mo /Hr DB /WB Blb Bulb (Btuh) (F) (F) (F) - 18,771 - 11,039 -5,283 - 18,117 -6,457 -6,739 - 12,834 -4,992 - 21,906 -15,566 - 16,486 - 138,190 - 138,189 - 11,660 - 25,437 -6,427 -2,234 -6,916 -4,960 - 10,545 -5,113 -5,595 - 11,528 - 21,142 -976 - 13,437 - 125,971 - 125,970 - 264,160 - 264,159 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 24 13/ 1 24 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Coil 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 77.6 77.6 V 600 PAGE 5 Coil Coil Air Sens. Flow Load (Cfm) (Btuh) 1,609 - 28,329 946 - 18,961 453 -6,483 1,553 - 30,083 553 - 11,384 578 - 12,369 1,100 - 17,188 428 -7,703 1,877 - 30,717 1,334 - 40,224 1,413 - 32,030 11,842 - 235,472 11,842 - 235,471 1,226 - 19,300 2,675 - 39,022 676 - 11,737 235 -5,436 727 - 15,312 522 -8,340 1,109 - 15,515 538 -7,282 588 -8,712 1,212 - 18,395 2,223 - 62,239 103 -2,873 1,413 - 28,982 13,247 - 243,144 13,247 - 243,144 25,089 - 478,616 25,089 - 478,615 CITY RECEIVED MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM HEATING - ALTERNATIVE 1 Room Number Description 1 2 3 4 5 6 7 8 9 10 11 lobby -1 Zone 1 Total /Ave. Zone 1 Block 12 13 14 15 16 17 18 19 20 21 22 23 24 lobby -2 Zone 2 Total /Ave. Zone 2 Block System 1 Total /Ave. System 1 Block PEAK HEATING (Main System) Space Peak OA Rm Supp. Space Floor Time Cond. Dry Dry Air Area Mo /Hr DB /WB Blb Bulb Flow (Sq Ft) (F) (F) (F) (Cfm) 896 13/ 1 24 21 68 78.6 1,609 768 13/ 1 24 21 68 78.6 946 96 13/ 1 24 21 68 78.6 453 1,152 13/ 1 24 21 68 78.6 1,553 480 13/ 1 24 21 68 78.6 553 552 13/ 1 24 21 68 78.6 578 384 13/ 1 24 21 68 78.6 1,100 256 13/ 1 24 21 68 78.6 428 800 13/ 1 24 21 68 78.6 1,877 2,496 13/ 1 24 21 68 78.6 1,334 1,536 13/ 1 24 21 68 78.6 1,413 9,416 24 21 68 78.6 11,842 9,416 13/ 1 24 21 68 78.6 11,842 720 13/ 1 24 21 68 76.7 1,226 1,248 13/ 1 24 21 68 76.7 2,675 512 13/ 1 24 21 68 76.7 676 320 13/ 1 24 21 68 76.7 235 832 13/ 1 24 21 68 76.7 727 320 13/ 1 24 21 68 76.7 522 448 13/ 1 24 21 68 76.7 1,109 192 13/ 1 24 21 68 76.7 538 288 13/ 1 24 21 68 76.7 588 640 13/ 1 24 21 68 76.7 1,212 4,160 13/ 1 24 21 68 76.7 2,223 192 13/ 1 24 21 68 76.7 103 1,536 13/ 1 24 21 68 76.7 1,413 11,408 24 21 68 76.7 13,247 11,408 13/ 1 24 21 68 76.7 13,247 20,824 24 21 68 77.6 25,089 20,824 13/ 1 24 21 68 77.6 25,089 LOADS Space Sens. Load (Btuh) - 18,771 - 11,039 -5,283 - 18,117 -6,457 -6,739 - 12,834 -4,992 - 21,906 - 15,566 - 16,486 - 138,190 - 138,189 - 11,660 - 25,437 -6,427 -2,234 -6,916 -4,960 - 10,545 -5,113 -5,595 - 11,528 - 21,142 -976 - 13,437 - 125,971 - 125,970 - 264,160 - 264,159 Peak Time Mo /Hr 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 13/ 1 24 24 13/ 1 24 24 13/ 1 24 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Coil OA Rm Supp. Cond. Dry Dry DB /WB Blb Bulb (F) (F) (F) 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 78.6 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 76.7 77.6 77.6 V 600 PAGE 5 Coil Coil Air Sens. Flow Load (Cfm) (Btuh) 1,609 - 28,329 946 - 18,961 453 -6,483 1,553 - 30,083 553 - 11,384 578 - 12,369 1,100 - 17,188 428 -7,703 1,877 - 30,717 1,334 - 40,224 1,413 - 32,030 11,842 - 235,472 11,842 - 235,471 1,226 - 19,300 2,675 - 39,022 676 - 11,737 235 -5,436 727 - 15,312 522 -8,340 1,109 - 15,515 538 -7,282 588 -8,712 1,212 - 18,395 2,223 - 62,239 103 -2,873 1,413 - 28,982 13,247 - 243,144 13,247 - 243,144 25,089 - 478,616 25,089 - 478,615 CITY RECEIVED CITY MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 INTERNAL COOLING LOADS (At time of Space Peak) V 600 PAGE 6 Lights Lights Misc. Misc. Misc. Room Ret. Air Lites People People Peopl Space Space Ret. Air Misc. Room Sensible Sensible CLF Sensible Latent CLF Sensible Latent Sensible CLF Total Number Description (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) 1 4,587 0 1.000 2,285 2,285 1.000 3,058 0 0 1.000 12,215 2 3,932 0 1.000 1,958 1,958 1.000 2,621 0 0 1.000 10,470 3 491 0 1.000 245 245 1.000 328 0 0 1.000 1,309 4 5,898 0 1.000 2,938 2,938 1.000 3,932 0 0 1.000 15,705 5 2,457 0 1.000 1,224 1,224 1.000 1,638 0 0 1.000 6,544 6 2,826 0 1.000 1,408 1,408 1.000 1,884 0 0 1.000 7,525 7 1,966 0 1.000 979 979 1.000 1,311 0 0 1.000 5,235 8 1,311 0 1.000 653 653 1.000 874 0 0 1.000 3,490 9 4,096 0 1.000 2,040 2,040 1.000 2,730 0 0 1.000 10,906 10 12,778 0 1.000 6,365 6,365 1.000 8,519 0 0 1.000 34,027 11 lobby -1 7,864 0 1.000 3,917 3,917 1.000 5,242 0 0 1.000 20,940 Zone 1 Total /Ave. 48,205 0 1.000 24,011 24,011 1.000 32,137 0 0 1.000 128,364 Zone 1 Block 48,205 0 1.000 24,011 24,011 1.000 32,137 0 0 1.000 128,364 12 3,686 0 1.000 1,836 1,836 1.000 2,457 0 0 1.000 9,815 13 6,389 0 1.000 3,182 3,182 1.000 4,259 0 0 1.000 17,013 14 2,621 0 1.000 1,306 1,306 1.000 1,747 0 0 1.000 6,980 15 1,638 0 1.000 816 816 1.000 1,092 0 0 1.000 4,362 16 4,259 0 1.000 2,122 2,122 1.000 2,840 0 0 1.000 11,342 17 1,638 0 1.000 816 816 1.000 1,092 0 0 1.000 4,362 18 2,294 0 1.000 1,142 1,142 1.000 1,529 0 0 1.000 6,107 19 983 0 1.000 490 490 1.000 655 0 0 1.000 2,617 20 1,474 0 1.000 734 734 1.000 983 0 0 1.000 3,926 21 3,276 0 1.000 1,632 1,632 1.000 2,184 0 0 1.000 8,725 22 21,297 0 1.000 10,608 10,608 1.000 14,198 0 0 1.000 56,711 23 983 0 1.000 490 490 1.000 655 0 0 1.000 2,617 24 lobby -2 7,864 0 1.000 3,917 3,917 1.000 5,242 0 0 1.000 20,940 Zone 2 Total /Ave. 58,403 0 1.000 29,090 29,090 1.000 38,936 0 0 1.000 155,520 Zone 2 Block 58,403 0 1.000 29,090 29,090 1.000 38,936 0 0 1.000 155,520 System 1 Total /Ave. 106,608 0 1.000 53,101 53,101 1.000 71,072 0 0 1.000 283,883 System 1 Block 106,608 0 1.000 53,101 53,101 1.000 71,072 0 0 1.000 283,883 CITY RECEIVED MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 INTERNAL HEATING LOADS (At time of Space Peak) Lights Lights Misc. Misc. Room Ret. Air Lites People Peopl Space Ret. Air Misc. Room Sensible Sensible CLF Sensible CLF Sensible Sensible CLF Total Number Description (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) 1 0 0 0.000 0 0.000 0 0 0.000 0 2 0 0 0.000 0 0.000 0 0 0.000 0 3 0 0 0.000 0 0.000 0 0 0.000 0 4 0 0 0.000 0 0.000 0 0 0.000 0 5 0 0 0.000 0 0.000 0 0 0.000 0 6 0 0 0.000 0 0.000 0 0 0.000 0 7 0 0 0.000 0 0.000 0 0 0.000 0 8 0 0 0.000 0 0.000 0 0 0.000 0 9 0 0 0.000 0 0.000 0 0 0.000 0 10 0 0 0.000 0 0.000 0 0 0.000 0 11 lobby -1 0 0 0.000 0 0.000 0 0 0.000 0 Zone 1 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 Zone 1 Block 0 0 0.000 0 0.000 0 0 0.000 0 12 0 0 0.000 0 0.000 0 0 0.000 0 13 0 0 0.000 0 0.000 0 0 0.000 0 14 0 0 0.000 0 0.000 0 0 0.000 0 15 0 0 0.000 0 0.000 0 0 0.000 0 16 0 0 0.000 0 0.000 0 0 0.000 0 17 0 0 0.000 0 0.000 0 0 0.000 0 18 0 0 0.000 0 0.000 0 0 0.000 0 19 0 0 0.000 0 0.000 0 0 0.000 0 20 0 0 0.000 0 0.000 0 0 0.000 0 21 0 0 0.000 0 0.000 0 0 0.000 0 22 0 0 0.000 0 0.000 0 0 0.000 0 23 0 0 0.000 0 0.000 0 0 0.000 0 24 lobby -2 0 0 0.000 0 0.000 0 0 0.000 0 Zone 2 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 Zone 2 Block 0 0 0.000 0 0.000 0 0 0.000 0 System 1 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 System 1 Block 0 0 0.000 0 0.000 0 0 0.000 0 V 600 PAGE 7 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 V 600 PAGE 8 BUILDING ENVELOPE COOLING LOADS (Roof - Skylight) (At time of Space Peak) Roof Roof Skylight Skylight Return Air Roof Space Roof Skylight Skylight Skylt Return Air Skylt Space Skylt Sensible R.A. Sensible Space Return Air Space Solar Conduction R.A. Conduction Space Room Load CLTD Load CLTD Solar Solar CLF Load CLTD Load CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 2 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 3 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 4 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 5 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 6 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 7 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 8 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 9 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 10 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 11 lobby -1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Block 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 12 -217 -10.0 0 -9.8 0 0 0.000 0 0.0 0 0.0 13 -177 -4.7 0 -4.5 0 0 0.000 0 0.0 0 0.0 14 -73 -4.7 0 -4.5 0 0 0.000 0 0.0 0 0.0 15 377 39.3 0 39,5 0 0 0.000 0 0.0 0 0.0 16 980 39.3 0 39.5 0 0 0.000 0 0.0 0 0.0 17 368 38.4 0 38.6 0 0 0.000 0 0.0 0 0.0 18 516 38.4 0 38.6 0 0 0.000 0 0.0 0 0.0 19 221 38.4 0 38.6 0 0 0.000 0 0.0 0 0.0 20 331 38.4 0 38.6 0 0 0.000 0 0.0 0 0.0 21 737 38.4 0 38.6 0 0 0.000 0 0.0 0 0.0 22 5,237 42.0 0 42.2 0 0 0.000 0 0.0 0 0.0 23 242 42.0 0 42.2 0 0 0.000 0 0.0 0 0.0 24 lobby -2 -541 -11.7 0 -11.5 0 0 0.000 0 0.0 0 0.0 Zone 2 Total /Ave. 8,000 23.4 0 23.6 0 0 0.000 0 0.0 0 0.0 Zone 2 Block 11,555 33.8 0 34.0 0 0 0.000 0 0.0 0 0.0 System 1 Total /Ave. 8,000 23.4 0 23.6 0 0 0.000 0 0.0 0 0.0 System 1 Block 11,555 33.8 0 34.0 0 0 0.000 0 0.0 0 0.0 Room Number Description 1 2 3 4 BUILDING ENVELOPE COOLING LOADS (Wall - Window) (At time of Space Peak) Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plea Space Space Space Return Air Solar Space Space Return Air R.A. Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) -29 -2.8 -67 -2.6 25,056 4 1.5 11 1.7 11,616 2 1.5 4 1.7 8,712 6 1.5 12 1.7 20,328 0 0.740 -1,403 -8.7 0 0.0 0 0.990 -446 -8.3 0 0.0 RECEIVEE, p 0 0.990 -335 - 8 . )jITy OF TUICWILA 0 0.990 -781 -8.3 0 0.0 MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 Room Number Description 5 4 0.5 18 0.7 6,624 0 0.960 -446 -8.3 0 0.0 6 5 0.9 11 1.1 6,720 0 1.000 -833 -6.2 0 0.0 7 29 5.6 74 5.8 18,312 0 0.990 292 3.1 0 0.0 8 14 7.3 40 7.5 5,952 0 1.000 83 3.1 0 0.0 9 44 7.3 90 7.5 29,760 0 1.000 417 3.1 0 0.0 10 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 11 lobby -1 -41 -5.6 -130 -5.4 13,056 0 0.980 -570 -10.6 0 0.0 Zone 1 Total /Ave. 38 0.7 63 0.5 146,136 0 0.936 -4,023 -4.8 0 0.0 Zone 1 Block 548 10.6 1,425 10.8 74,472 0 0.511 3,726 4.4 0 0.0 12 -26 -2.5 -68 -2.3 18,360 0 0.710 -726 -6.0 0 0.0 13 14 1.5 33 1.7 43,560 0 0.990 -1,673 -8.3 0 0.0 14 6 1.5 20 1.7 8,712 0 0.990 -335 -8.3 0 0.0 15 45 10.4 158 10.6 1,344 0 1.000 -167 -6.2 0 0.0 16 5 0.9 14 1.1 6,720 0 1.000 -833 -6.2 0 0.0 17 15 5.2 30 5.4 7,080 0 0.940 208 3.1 0 0.0 18 24 7.3 47 7.5 17,856 0 1.000 250 3.1 0 0.0 19 14 7.3 31 7.5 8,928 0 1.000 125 3.1 0 0.0 20 10 7.3 16 7.5 8,928 0 1.000 125 3.1 0 0.0 21 28 7.3 61 7.5 17,856 0 1.000 250 3.1 0 0.0 22 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 23 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 24 lobby -2 -39 -5.8 -124 -5.6 13,056 0 0.980 -570 -10.6 0 0.0 Zone 2 Total /Ave. 96 1.8 218 1.6 152,400 0 0.946 -3,345 -3.8 0 0.0 Zone 2 Block 599 11.1 1,551 11.3 80,304 0 0.537 3,903 4.4 0 0.0 System 1 Total /Ave. 134 1.3 281 1.0 298,536 0 0.941 -7,368 -4.2 0 0.0 System 1 Block 1,148 10.8 2,976 11.1 154,776 0 0.524 7,629 4.4 '0 0.0 Room Number Description 1 2 3 4 5 6 7 8 BUILDING ENVELOPE COOLING LOADS (Wall - Window) (At time of Space Peak) V 600 PAGE 9 Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plena Space Space Space Return Air Solar Space Space Return Air R.A. Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) BUILDING ENVELOPE COOLING LOADS (Exposed Floor - Partitions - Infiltration) (At time of Space Peak) Exposed Expsd Plena Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total (Btuh) (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 0 0.0 0 0.0 0 0 0 75.2 68 23,624 0 0.0 0 0.0 0 0 0 75.2 58 11,243 0 0.0 0 0.0 0 0 0 75.2 7 8,390 0 0.0 0 0.0 0 0 0 75.2 87 19,651 0 0.0 0 0.0 0 0 0 75.2 36 6,236 0 0.0 0 0.0 0 0 0 75.2 42 5,944 0 0.0 0 0.0 0 0 0 75.2 CITY OFT �g RECEI 6 , 0 0.0 0 0.0 0 0 0 75.2 19 , MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 Room Number Description V 600 PAGE 10 BUILDING ENVELOPE COOLING LOADS (Exposed Floor - Partitions - Infiltration) (At time of Space Peak) Exposed Expsd Plenm Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total (Btuh) (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 9 0 0.0 0 0.0 0 0 0 75.2 60 30,371 10 0 0.0 0 0.0 0 0 0 75.2 188 188 11 lobby -1 0 0.0 0 0.0 0 0 0 75.2 116 12,432 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0 75.2 710 142,924 Zone 1 Block 0 0.0 0 0.0 0 0 0 75.2 710 80,881 12 0 0.0 0 0.0 0 0 0 75.2 54 17,378 13 0 0.0 0 0.0 0 0 0 75.2 94 41,850 14 0 0.0 0 0.0 0 0 0 75.2 39 8,369 15 0 0.0 0 0.0 0 0 0 75.2 24 1,781 16 0 0.0 0 0.0 0 0 0 75.2 63 6,949. 17 0 0.0 0 0.0 0 0 0 75.2 24 7,725 18 0 0.0 0 0.0 0 0 0 75.2 34 18,727 19 0 0.0 0 0.0 0 0 0 75.2 14 9,333 20 0 0.0 0 0.0 0 0 0 75.2 22 9,433 21 0 0.0 0 0.0 0 0 0 75.2 48 18,980 22 0 0.0 0 0.0 0 0 0 75.2 314 5,551 23 0 0.0 0 0.0 0 0 0 75.2 14 256 24 lobby -2 0 0.0 0 0.0 0 0 0 75.2 116 11,898 Zone 2 Total /Ave. 0 0.0 0 0.0 0 0 0 75.2 861 158,230 Zone 2 Block 0 0.0 0 0.0 0 0 0 75.2 861 98,773 System 1 Total /Ave. 0 0.0 0 0.0 0 0 0 75.2 1,571 301,154 System 1 Block 0 0.0 0 0.0 0 0 0 75.2 1,571 179,654 RECEIVED CITY OF TUKWIL MAR. 2 0 1998 PERMIT CENTER Room Number Description 1 2 3 4 5 6 7 8 9 10 11 lobby -1 Zone 1 Total /Ave. Zone 1 Block 12 13 14 15 16 17 18 19 20 21 22 23 24 lobby -2 Zone 2 Total /Ave. Zone 2 Block System 1 Total /Ave. System 1 Block Room Number Description 1 2 3 4 Trane Air Conditioning Economics V 600 By: Comfort Plus PAGE 11 HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 BUILDING ENVELOPE HEATING LOADS (Roof - Skylight) (At time of Space Peak) Roof Roof Skylight Skylight Return Air Roof Space Roof Skylight Skylight Skylt Return Air Skylt Space Skylt Sensible R.A. Sensible Space Return Air Space Solar Conduction R.A. Conduction Space Load CLTD Load CLTD Solar Solar CLF Load CLTD Load CLTD (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 -938 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -1,626 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -667 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -417 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -1,084 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -417 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -584 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -250 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -375 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -834 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -5,420 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -250 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 -2,001 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 - 14.864 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 - 14.864 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 - 14.864 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 - 14.864 -43.4 0 -44.0 0 0 0.000 0 0.0 0 0.0 BUILDING ENVELOPE HEATING LOADS (Wall - Window) (At time of Space Peak) Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plenm Space Space Space Return Air Solar Space Space Return Air R.A. Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) -438 -43.4 -1,140 -44.0 - 125 -43.4 -296 -44.0 -63 -43.4 -95 -44.0 - 167 -43.4 -306 -44.0 0 0 0 0 0.000 0 0.000 0 0.000 0 0.000 -7,435 -44.0 0 0.0 -2,478 -44.0 RECEA/ED 0.0 - 1,859 -44.0 CITY OF $UKW li - 4,337 -44.0 MAR 2 0 1g gg PERMIT CENTER Room Number Description Room Number Description 1 2 3 4 5 6 7 8 Trane Air Conditioning Economics V 600 By: Comfort Plus PAGE 12 HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 BUILDING ENVELOPE HEATING LOADS (Wall - Window) (At time of Space Peak) Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plena Space Space Space Return Air Solar Space Space Return Air R.A. Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 5 -334 -43.4 -1,140 -44.0 0 0 0.000 -2,478 -44.0 0 0.0 6 -240 -43.4 -444 -44.0 0 0 0.000 -6,196 -44.0 0 0.0 7 -229 -43.4 -560 -44.0 0 0 0.000 -4,337 -44.0 0 0.0 8 -83 -43.4 -232 -44.0 0 0 0.000 -1,239 -44.0 0 0.0 9 -261 -43.4 -528 -44.0 0 0 0.000 -6,196 -44.0 0 0.0 10 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 11 lobby -1 -313 -43.4 -1,056 -44.0 0 0 0.000 -2,478 -44.0 0 0.0 Zone 1 Total /Ave. -2,251 -43.4 -5,797 -44.0 0 0 0.000 - 39,034 -44.0 0 0.0 Zone 1 Block -2,251 -43.4 -5,797 -44.0 0 0 0.000 - 39,034 -44.0 0 0.0 12 -438 -43.4 -1,299 -44.0 0 0 0.000 -5,576 -44.0 0 0.0 13 -407 -43.4 -855 -44.0 0 0 0.000 -9,294 -44.0 0 0.0 14 -167 -43.4 -517 -44.0 0 0 0.000 -1,859 -44.0 0 0.0 15 -188 -43.4 -655 -44.0 0 0 0.000 -1,239 -44.0 0 0.0 16 -271 -43.4 -570 -44.0 0 0 0.000 -6,196 -44.0 0 0.0 17 -125 -43.4 -243 -44.0 0 0 0.000 -3,098 -44.0 0 0.0 18 -146 -43.4 -275 -44.0 0 0 0.000 -3,718 -44.0 0 0.0 19 -83 -43.4 -180 -44.0 0 0 0.000 -1,859 -44.0 0 0.0 20 -63 -43.4 -95 -44.0 0 0 0.000 -1,859 -44.0 0 0.0 21 -167 -43.4 -359 -44.0 0 0 0.000 -3,718 -44.0 0 0.0 22 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 23 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 24 lobby -2 -292 -43.4 -972 -44.0 0 0 0.000 -2,478 -44.0 0 0.0 Zone 2 Total /Ave. -2,345 -43.4 -6,019 -44.0 0 0 0.000 - 40,893 -44.0 0 0.0 Zone 2 Block -2,345 -43.4 -6,019 -44.0 0 0 0.000 - 40,893 -44.0 0 0.0 System 1 Total /Ave. -4,597 -43.4 - 11,817 -44.0 0 0 0.000 - 79,926 -44.0 0 0.0 System 1 Block -4,597 -43.4 - 11,817 -44.0 0 0 0.000 - 79,926 -44.0 0 0.0 BUILDING ENVELOPE HEATING LOADS (Exposed Floor - Partitions - Infiltration) (At time of Space Peak) Exposed Expsd Plena Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total (Btuh) (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 0 0.0 0 0.0 0 0 0 67.4 -162 -9,175 0 0.0 0 0.0 0 0 0 67.4 -139 -3,038 0 0.0 0 0.0 0 0 0 67.4 -17 -2,034 0 0.0 0 0.0 0 0 0 67.4 -208 -5,018 0 0.0 0 0.0 0 0 0 67.4 -87 -4,039 0 0.0 0 0.0 0 0 0 67.4 -100 -6,979 0 0.0 0 0.0 0 0 0 67.4 -6 93ECEIVE6, 195 0 0.0 0 0.0 0 0 0 67,4 C46 OF TUKyygp! MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 Room Number Description V 600 PAGE 13 BUILDING ENVELOPE HEATING LOADS (Exposed Floor - Partitions - Infiltration) (At time of Space Peak) Exposed Expsd Plea Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total (Btuh) (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 9 0 0.0 0 0.0 0 0 0 67,4 -144 -7,129 10 0 0.0 0 0.0 0 0 0 67.4 -450 -451 11 lobby -1 0 0.0 0 0.0 0 0 0 67.4 -277 -4,124 Zone 1 Total /Ave. 0 0.0 0 0.0 0 -1 0 67.4 -1,699 - 48,783 Zone 1 Block 0 0.0 0 0.0 0 0 0 67,4 -1,699 - 48,782 12 0 0.0 0 0.0 0 0 0 67.4 -130 -8,381 13 0 0.0 0 0.0 0 0 0 67.4 -225 - 12,407 14 0 0.0 0 0.0 0 0 0 67.4 -92 -3,303 15 0 0.0 0 0.0 0 0 0 67.4 -58 -2,556 16 0 0.0 0 0.0 0 0 0 67.4 -150 -8,271 17 0 0.0 0 0.0 0 0 0 67.4 -58 -3,941 18 0 0.0 0 0.0 0 0 0 67.4 -81 -4,803 19 0 0.0 0 0.0 0 0 0 67.4 -35 -2,407 20 0 0.0 0 0.0 0 0 0 67.4 -52 -2,444 21 0 0.0 0 0.0 0 0 0 67.4 -116 -5,193 22 0 0.0 0 0.0 0 0 0 67.4 -751 -6,171 23 0 0.0 0 0.0 0 0 0 67.4 -35 -285 24 lobby -2 0 0.0 0 0.0 0 0 0 67.4 -277 -6,020 Zone 2 Total /Ave. 0 0.0 0 0.0 0 -1 0 67.4 -2,059 - 66,180 Zone 2 Block 0 0.0 0 0.0 0 0 0 67,4 -2,059 - 66,179 System 1 Total /Ave. 0 0.0 0 0.0 0 -1 0 67.4 - 3,758 - 114,963 System 1 Block 0 0.0 0 0.0 0 0 0 67.4 -3,758 - 114,961 RECEIVED C ITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus BUILDING U- VALUES - ALTERNATIVE 1 BUILDING U- VALUES Room U- Values Room Room (Btu /hr /sqft /F) Mass Capac. Room Summr Wintr Summr Wintr (lb/ (Btu/ Number Description Part. ExF1r Skylt Skylt Roof Windo Windo Wall Ceil. sqft) sqft/F) 1 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 96.1 19.02 2 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 39.1 7.76 3 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 90.6 17.93 4 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 32.6 6.48 5 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 157.5 31.17 6 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 71.5 14.17 7 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 109.9 21.75 8 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 71.3 14.12 9 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 59.7 11.83 10 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.317 13.3 2.67 11 lobby -1 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 55.2 10.94 Zone 1 Total /Ave. 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 53.5 10.61 12 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 178.8 36.38 13 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 113.0 23.39 14 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0,050 0.317 128.2 26.40 15 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 189.1 38.42 16 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 113.0 23.39 17 0.000 0.000 0.000 0.000 0.030 0,560 0.587 0.050 0.317 119.5 24.68 18 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 109.6 22.72 19 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 129.8 26.71 20 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 91.2 19.08 21 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 104.1 21.63 22 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.317 65.5 13.99 23 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.317 65.5 13.99 24 lobby -2 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 104.1 21.63 Zone 2 Total /Ave. 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 99.9 20.80 System 1 Total /Ave. 0.000 0.000 0.000 0.000 0.030 0.560 0,587 0.050 0.317 78.9 16,19 Building 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 78.9 16.19 V 600 PAGE 14 CITY RECEIVED MAR 2 0 1998 PERMIT CENTER M BUILDING AREAS - ALTERNATIVE 1 ASHRAE 90 ANALYSIS - ALTERNATIVE 1 Trane Air Conditioning Economics V 600 By: Comfort Plus PAGE 15 Floor Total Exposed Number of Area /Dupl Floor Partition Floor Skylight Skl Net Roof Window Win Net Wall Room Duplicate Room Area Area Area Area /Rf Area Area /W1 Area Number Description Flr Rm (sqft) (sqft) (sqft) (sqft) (sqft) ( %) (sqft) (sqft) ( %) (sqft) 1 1 1 896 896 0 0 0 0 0 288 29 720 2 1 1 768 768 0 0 0 0 0 96 33 192 3 1 1 96 96 0 0 0 0 0 72 50 72 4 1 1 1,152 1,152 0 0 0 0 0 168 44 216 5 1 1 480 480 0 0 0 0 0 96 13 672 6 1 1 552 552 0 0 0 0 0 240 43 312 7 1 1 384 384 0 0 0 0 0 168 32 360 8 1 1 256 256 0 0 0 0 0 48 25 144 9 1 1 800 800 0 0 0 0 0 240 40 360 10 1 1 2,496 2,496 0 0 0 0 0 0 0 0 11 lobby -1 1 1 1,536 1,536 0 0 0 0 0 96 13 624 Zone 1 Total /Ave. 9,416 0 0 0 0 0 1,512 29 3,672 12 1 1 720 720 0 0 0 0 720 216 21 792 13 1 1 1,248 1,248 0 0 0 0 1,248 360 38 576 14 1 1 512 512 0 0 0 0 512 72 19 312 15 1 1 320 320 0 0 0 0 320 48 11 384 16 1 1 832 832 0 0 0 0 832 240 38 384 17 1 1 320 320 0 0 0 0 320 120 42 168 18 1 1 448 448 0 0 0 0 448 144 43 192 19 1 1 192 192 0 0 0 0 192 72 38 120 20 1 1 288 288 0 0 0 0 288 72 50 72 21 1 1 640 640 0 0 0 0 640 144 38 240 22 1 1 4,160 4,160 0 0 0 0 4,160 0 0 0 23 1 1 192 192 0 0 0 0 192 0 0 0 24 lobby -2 1 1 1,536 1,536 0 0 0 0 1,536 96 14 576 Zone 2 Total /Ave. 11,408 0 0 0 0 11,408 1,584 29 3,816 System 1 Total /Ave. 20,824 0 0 0 0 11,408 3,096 29 7,488 Building 20,824 0 0 0 0 11,408 3,096 29 7,488 ASHRAE 90 ANALYSIS Overall Roof U -Value = 0.030 (Btu /Hr /Sq Ft /F) Overall Wall U -Value = 0.199 (Btu /Hr /Sq Ft /F) Overall Building U -Value = 0.111 (Btu /Hr /Sq Ft /F) BUILDING AREAS Roof Overall Thermal Transfer Value (OTTVr) = 0.40 (Btu /Hr /Sq Ft) Wall Overall Thermal Transfer Value (OTTVw) = 25.37 (Btu /Hr /Sq Ft) CITY OF MAR 2 0 1998 PERMIT CENTER City of Tukwila Fire Department Fire Department Review Control #M98 -0058 (512) Re: Boeing Employees Credit Union - 625 Andover Park West Dear Sir: March 25, 1998 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Call the Tukwila Fire Department at 575 -4407. for John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila. WashlnRton 98188 • Phone: 1206) 575.4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, cc: TFD file ncd The Tukwila Fire Prevention Bureau John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headouarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206)5754404 • Fax (206) 575.4439 ALL! ST AI nee■eun- - v 1111_ 11.11II11111 111 1111 IPIi . __ x_1■■11001:1--11-.. 11110_'_ ■_i 'J111 i 101110 1111l:111u■■.I ■ ■m■111�11 1iriiii li►! 1i" r ii111111ilIIilIIilli!li IIIll luHir 1=11 _, 111 ' '■ II III II IM I1i1 1111 1 ��1' a 11111a 1, _ma -# i war 110 "NW W1 II■I!�■I IOII111 II■11EI ` 1IIIF1IiI1 1u11 �-a■ ;111!:==■!!! .! 11111111 = r II ■u��rvrr. ■'����4 _x �� �. IJ " dllllllll rdra r_ tiii, ■I�I, INI iii a _ ! � DIn® m �\o�l "�11 1111�� 111111 y '■I'�i I1�1rsommo ,a�ounlniJ 250 jlil. jIII1 ©III 1EI0III "II ," , h"II■■ iiiII1111iI1 ` 1 •FAME' I II I , IIII■ ■ II�■..�IIIIGINEMI ■11111■ �r"II� �1.W��tm��aa_ 0 C /�IIaaY�� == .Irar. �, I I 11I sill■11■ ■iIii rgrr.!__ 1111911III ■1 .� 11� ��''' 1�1111i■ a r�r7 \ u 1-.� 1111171i111121■11111 ®m/ll,lll,lI ,'- I1011111111111111111lll 1�� IIAI111111 ■111111111 _ 1■ - 1 i► ■■■ ■• II•ul UIIIrJ• II Illlllllllill 111 °� 11.11 ■ ■ ■N ■ ■It�ll ■■ I Illr lo issr i r ■ al e 11111 � e ■��I� 1�!Alllla l-, I . it T 11 '� 1 � .eP 11 1 n. �ilrl !■rrl� i®■11I'I1 ow : a nu l . el `a l��iinumi�rs ll_01111■ � 1t111l;livot 1 Ill � LU .IU ■..III !II - IDw.r Illlln s.:�■�■■ SIR � I _ Ill :11 1311111 'll ;� .:I �!111iRLIIIII _ 1 11119 1illlll1;l lnaiilidE1111111111r "� 1 l — ■ I: i'ti ,ld! J '.I'� I i� ■I��i , � HIS 1 , I IIIIIIr �..�■11111�111 . ' , o '' ' �: ainnwelsormora, II 1 ��. !! ' � � . a�� �1p• � ELECT. iIhlII leilii'K.� lr 00111121715111111111111 , _41111`11 f_I 1IILuII iiel I0 " 1- 1 II'cli1 �1 11111 IIII IIII IIII :: ` NI 1 tN 5203 CORRIDOR 520P 1 ' M q8 865g UPPER FLOOR PLAN l /8 - I nn C PROVIDE a/INSULATED SUB -BASE FROVIDE a/NS LATED SUB -BABE TD n MULLIO ...... 16 ...wean-mom ..,;,RF „ VIII -, r.r��.. �■ � ■' � it *�� li 1 COFFEE 1 ■I JII ■w ;'9III�■I� ■� I .. t 2 117/ J m1 1 . ■u I■Iuen�Jll' • lui ■I ■I■o . ' ! I �w�■a- ."""1 11 _ I ► i� iIl�nllha '_�” 11 1 r GRILLE y �® �) ♦I , MID I■.'//,I L➢ I e■ r Z� .T I.�aI /l 1.4 is ill � ME �) 1! i111III 111 / m 111111° .� iv klaas� 10 lal —_ 61,214 31I11irI_ �'`�1„„��, l�1 } }II — -Yl MOM x 1 1 1 11111 1 1 i, 1 i Ii1I 11 1-1 11111111�i1 lz+ L.I11 1�0 I mg FRONDE u/NS ATE) SLBBARE ■■■: ■• ®� 1111111111111121111111113111'211 011111114111111111:2111121111211M111 . si�l�l :allir�11o111i111i1111111u1�!' ii1IIIIilIv1iuIIIII1flIHuIh 11 11111111110 .:.� WES II�I11ui �e = ■�11 ■ + eramenunciatiming- U LL!D 111 1 _l 111111141 ,11111141111 l 'I j __ _ T� ����Il� I =IICi 2�� ����� F ■ I1" ._o X111 ■I���� ��II!■■■r.L.1_i aim II ,� ••1■ 1. Uj ■3■IIIi ■ `: LI■ !_ I!�! !!ILIA l..4 IE I� ! I : iiiL!u1 MJLL10 .� 11 1 1 II N��'. a.■■.11 1: 1> h111110111 i I■� i11 ii111I1911 11 ■ ■ ■■vl■■ �� 1111111111111=1= IIII�I 1cGdM 1111 11! '=!!IIIII!IIIIIII U ull!11 .`f iii!!_II!!!1 ■I� a a�+� C.m.��a.a.. :111 :0 II1111i IIII 1111111111111161_ ■I ■ - ■ IIiIIIIiI:o L 1 I ■ 11. .111 -1� AIL__ _ : _ � III - �■1 �►10�1_II MEM ■n I1o■Ir 11� �.. `�� _LIB ■■mo■ � ��'� 1 I r 11 o % , „ ■�11 �,I�i�4111111161 �1� MIL II!!! � � I!ta.t..112. CORRIDOR l 5101 STAIR 5124 PROVIDE ■/NSI.ATED 81060.8E STAIR LOWER FLOOR PLAN A224wDON 14 PLACE 5 5F Cf. ION . . 1/8 - r-o KEY PLAN NTd fl NOTES: 0 0 0 0 WX2 ON4FAfOD • gel f j 101 INDUCT O/3.10 800 r 102 noau 400 103 INDUCT0/31f15 1500 104 MDUCTOMF52000 2000 105 MDUCTO/ 1600 106 MDUCTO/ 1200 101 ...N/C% 600 5 1es MDUCTO/ 1200 w 109 REDDI/ 400 1 20 REDDI/ 600 I " INDUCT0/3HF15 1200 IQ TITUS/REV 600 1B TITUB)FTFV 000 201 5DUCT0/3HF15 1200 202 203 200 204 INDUCTOAF52000 2000 2 05 MDUCTO /. , 1200 20 14DUCTO/ 1600 201 MDUCTO/ 000 a, 208 PIDUCTO/ 1200 6 205 ' REDDI/ 200 i 210 0155510/ 200 7 211 DDI/ 400 2112 111US/PI'FV 800 213 TINB!F4FV 8210 214 TB2OIPFV 600 VICINITY MAP FLTd 24k 24'000 (0R 24'124246) FOR LOCAL RE111R4 AIR TO VAV BOX GRILLE IS EXI8T'G SNAIL BE RELOCATED TO LOCATION 601CATED. EXTEND/PROVIDE NEW 16': DUCT FROM GRILLE TO EXISTS VAV BOX SERVNG THIS AREA PROVIDE VOL OFTPR • VAV R4 PLOUL 24 o 24'R0G (OR 24 ctrRA) FOR GENERAL PA TO CENTRAL UNIT. GRILLE 16 EXISTS 4 SHALL BE RELOCATED TO LOCATION FJDICATED. EMQJD,PROVIDE 400 164 DUCT FROM GRILLE TO EXIST* CENTRAL. RA DUCT. PROVIDE VOL DMPR • HAM TRNC RELOCATED T -BTAT. VERIFY ACTUAL LOCATION ON SITE w/CPI ENG PROR TO ROUGH -M. RELOCATE EX1STG FPVAVNAY BOX AS 601501ED. EXTEND OXIBT'G SUPPLY AIR DUCT AS REDD. 0 NEW FAN PO2ERED VAV (FPVAV) CR COOLING ONLY NAV) BOX PROVIDE COMECTION TO EXIST* PRIMARY SUPPLY AIR DUCT AS REDID, SIZE PER 80X INLET. PROVIDE w/SUPP1X H 00284 AIR PLENri0 AS MDICATED. SIZE BOX AS INDICATED CN SCHEDULE BELOW. 0 REMOVE D(18150 moiled 4 RETURN TO CLL•ER RE110vE DOUNBTFEAM DUCT 4 GRID 0 RERAN AIR TRANSFER ASSEMBLY WORD SIZE INDICATED. FOR 24' x V GRILLES, WTERGCMECTS6 DUCT SHALL ea 12'.. FOR 20 x 24' GRILLES PROVIDE 164 DUCT. DIFFUSER SCHEDULE CFM RATYaE co NECK SIZE DUCTOPM -04 SIZE 0.00 6'86' 6'1 101. 8'x8' 84 201 - 350 Wog' IVO 351 -500 2' x2' 24 501 - 680 14' x14' 14'4 65 -880 16 K' 144 881 -125 18'x0• 16 vAv SCHEDULE YLi 10 .0/3 3 211/1 14 480/3 (2).8 .0/3 4 5 211/1 211/1 115 4800 3 2TI/1 4 252/1 2 11 4 3 211/1 480/3 211/1 252/1 211/1 211/1 VA EC DUCT COIL VAV w/ELEC DUCT COIL FPVAv VAV w/ELEC DUCT COILS 208/1 VAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL FED FPVAV NEW FPVAV 13 480/3 VAV w/ELEC DUCT COIL (21. B 480/3 VAV w/ELEC DUCT COILS 4 480/3 .VAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL vAV w/ELEC DUCT COIL NEW 19.40 NEW FPVAV FEW 00000 EXHAUST FAN SCHEDULE TEF FTSNN R -10, 410 CR1 • DV BP, 130 W41TT8, 20A, 1000 Rif WMTEGRAAL 5ACKDR0+FT DMPR 2 INR MINTED SPEED WATCH 4 10• DUCT UP TO ROOF HOOD. CONTROL a/REVERSE ACT84G 114ER710BTAT SET TO ACTIVATE FAN • 15' F. (ADJUSTABLE). WR IEGT • 36•.. Corporate Square Building "5 Southcenter Corporate Square Andover Park West Tukwila, WA Uv4G Floor Plans - BIdd 5 M9a -o NUMBER 3/1804 3RNA DATE SCALE: AS NOTED DATE: 3/2/94' REVISED 9EZIL Floor Plan pr Arch Dug. 4E00 Tenant Improvement REVISIONS COMFORT 6617 S. 193rd Place, Suite #P105 ., KENT, WA 98032 (425)251-9840 (425)251-9871 (Fax) PROJECT NO. CONTR. NO. DRAWN BY: CHECKED BY: M - I RECE /Eo ciry o= T�ewiu