Permit M98-0059 - BOEING EMPLOYEES CREDIT UNION (BECU)
b - voiun +I Paa - D ;9431 cktA3 oaoca City of Tukwila ( Permit No: M98 -0059 Type: B -MECH Category: NRES Address: 655 ANDOVER PK W Location: BUILDING #7 Parcel #: 262304 -9075 Contractor License No: COMFOP *064D2 Permit Description: UMC Edition: 1994 MECHANICAL PERMIT INSTALL : NEW VAV BOXES, 6'PNUEM.' T /S, 5 S /F., DAMPERS,: 1-15 TON LIEBERT,. EXHAUST FANS, RELOCATE AIR DISTRIBUTION. Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 TENANT BOEING EMPLOYEES CREDIT UNION 655 ANDOVER PK W, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTRACTOR COMFORT PLUS Phone: 206 251 -9840 PO BOX 913, KENT WA 98032 CONTACT HERB JACKSON Phone: 425 - 251 -9840 6617 S 193 PL, #P -105, KENT, WA 98032, Valuation: Total Permit Fee: (206) 431-3670 Status: ISSUED Issued: 04/14/1998 Expires: 10/11/1998 * * * * ** * * * ** k * * * * * *4k * *** *4 * * * * * * ** *********** .t4 * *4* * * * * *.* *!t * * * * * ** * ** At * ** ** ,840.00 88.75 * * * * * * * * ** ***** Perm t Center Au horized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances` governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority, to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Dater \' — Print Name: ?.c��n (�E Title: This permit shall become n'ull'and void .'if the :.,work is not commenced within 180 days from the date of issuanc'e,.. :Or.:`1f the work is suspended or abandoned for a period of 180 days from the last inspection. City of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0059 Type: B -MECH Category: NRES Address: 655 ANDOVER PK W Location: BUILDING #7 Parcel #: 262304 -9075 Contractor License No: COMFOP *064D2 TENANT BOEING EMPLOYEES CREDIT UNION 655 ANDOVER PK W, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTRACTOR COMFORT PLUS Phone: 206 251 -9840 PO BOX 913, KENT WA 98032 CONTACT HERB JACKSON Phone: 425 - 251 -9840 6617 S 193 PL, #P -105' KENT, WA 98032 k********************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Permit Description: INSTALL 5 NEW•VAV BOXES, 6 PNUEM. T /S, 5 S /F.. DAMPERS, 1 -15 TON LIEBERT, 5 EXHAUST FANS, RELOCATE AIR DISTRIBUTION. UMC Edition: 1994 MECHANICAL PERMIT Valuation: Total Permit Fee: * * * * * * * * ** *********************** •k * * * * *'k * * ** * * * * * * *'k * * * * * * * ** (206) 431 -3670 Status: ISSUED Issued: 04/14/1998 Expires: 10/11/1998 '840.00 88.75 — glAr Perm t Center Au hor zed Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances, governing this work. will be complied with, whether:specified herein or not. The granting of this permit does not presume to give authority td violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to ,S1,0 for and obtain this' building permit.. Date: Print Name: Title: This permit shall become null and void: if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Project Namerrenant Description of work to be done: • - KtSj 1C PIW / 5 d - ei►+pu3 1—t --o-f Liebt i- 5 &laic. f' , Mlo Bar di,#ih - on ,� Will there be storage of flammable /combustible hazardous material in the building? El yes L1'"no Attach list of materials and stoma a location on separate 81/2 X 11 paper indicating uantities & Material Safet Data Sheets 71 Above Ground Tanks U Antennas /Satellite Dishes U Bulkhead /Docks Commercial Reroof ❑ Demolition ❑ Fence allochanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting Value of Construction: Site Address: [ Phone: City State /Zip: Tax Parcel Number Property wner: /.1 City /State /Zip: 0 Water Pone: Street Address: ... r 1 .!' J z i - t • Q. City State /Zip: 4 1 ;101 Fax #: Contact Person: fa P qne: Street Address: i/ . n3 RI)Pi. 4 -- .. ....a.. . City State /Zip: -.� z Fax #: Contrac P ne: C442/7 t Street Address: (q5 f�l. ` - -let� �f - � Gt�e.. City State /Zip: 48�3z— F #: y zV 7.51 Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) ; .: Description of work to be done: • - KtSj 1C PIW / 5 d - ei►+pu3 1—t --o-f Liebt i- 5 &laic. f' , Mlo Bar di,#ih - on ,� Will there be storage of flammable /combustible hazardous material in the building? El yes L1'"no Attach list of materials and stoma a location on separate 81/2 X 11 paper indicating uantities & Material Safet Data Sheets 71 Above Ground Tanks U Antennas /Satellite Dishes U Bulkhead /Docks Commercial Reroof ❑ Demolition ❑ Fence allochanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application ❑ Channelizatlon /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule* ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: CITY OF TI('(WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT. REQUEST FOR MISCELLANEOUS PUBLIC. WORKS PERMITS Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application « to 2. _ I Date application e I Apptic on ken by: (Initials) % • l MISCPMT.DOC 7/11/96 BUILDING 0 NE" 0 AUT ORIZ AGENT: PERMIT REVIEW Submit checklist No: M -9 0 Signatur =• Submit checklist No: M -1 Awnings /Canopies - No signage Date: 411 Print name .A. - _ oi '' 0 . A ,,... Address: 6,6, t-7 6 5 . r q3 Pr. , 7"- - ity/ le/ p: ; u? 4. 98032- 71 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist No: M -9 0 Antennas /Satellite Dishes Submit checklist No: M -1 Awnings /Canopies - No signage Commercial Tenant Improvement Permit Bulkhead /Dock Submit checklist No: M -10 El Commercial Reroof Submit checklist No: M -6 0 Demolition Submit checklist No: M -3, . M -3a El Fences - Over 6 feet in Height Submit checklist No: M -9 Land Altering /Grading /Preloads Submit checklist No: M -2 El Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 © /Mechanical (Residential & Commercial) Submit checklist No. M -8, Residential only - H -6, H -16 El Miscellaneous Public Works Permits Submit checklist No: H -9 0 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M -5 0 Moving Oversized Load /Hauling Submit checklist No: M -5 0 Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist . No: M -6 El Retaining Walls - Over 4 feet in height Submit checklist No: M -1 0 Temporary Facilities Submit checklist No: M -7 0 Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 El Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PE IT APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: ➢ tr p N'# aWfNCaS H 4A BE AT A LEGIBLE SCALE AND NEATLY DRAWN •, % ➢ B L'DIOIG'Sl' iPI.Aptti:AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT•DO0.' /.96 fk ' r ; - r •t c` 4 , 0"..v.111 t Nat t CITY OF TUKWILA Address: 655 ANDOVER PK W Suite: Tenant: BOEING EMPLOYEES CREDIT UNION Type: B -MECH Parcel #: 262304 -9075 *• k• A**• A**- k• k• k**• k'• k**• k***• k*• k• k• k• M****' k*.*. p. k. k ** * *•k•k•k•A''AA•k•k *•A•*•A *•k A'• 'A*'*k•A•kk-k•A Permit Conditions: 1. No changes w i l l be made to the plans un l ess approved by the Architect or Engineer and th.e.. u15 1, ., Division. 2. Al '1 permits, i nspect i,on,.'recur i's ; I.;: n ,' ro,ved plans s:ha l l be available at the job ^We .i'r for to tire" s- tar?tw ',uf any con- struction. Thee ,¢dou to- be maintathed- -.and avail- able until final , i`nspecGio ,approval is gr apte . All construct thn to -:d -be one im"donforfmance 4thappr li ved plans and. r~e,.eui re.ments, of the .,Un ►furor Building Code ' (1 994 .Edition) , as•amende 'd,` UniformMechani'ca'i:.Code C1 99,4 , Ed ition ), and . Wash ngton State Energy. `Code (1994 Ed''i.t,ion:) r ` 4. Va l i d i,, - ty of Pei mi t . , The ,,i ssi►ance.;of a permit- , or. approval' °.,`:,of plans, r specif icati,ons,, and computations shall' not he±. conm str ued to 'b,,e a p.ermi t, • �f.,or ~,' `v.r an .:approval. of, any v olation.': of any of ;the provisions of ';the bu i l d i ng code or of , ,.any other or of the . juris:dIction,,. No permit presuming . t: er >a givuthor ity,' to violate or cancel the provisions x.of tai's code ',:: hall he valid: : . ' 5. MAFACTURERS; INSTALLATION ,TRU1 INS T NU S REpUIRED ON SITE FO,W!THE BU;ILDINt NSPECTORS REVIEW; , F ., -_.5 6. E l;e:4.tr i ca l,; permits ' sha�'l l be', i ne`d through the Wash ingo t tn. State U;l;;W ;vision �if..Lab'or- and ',:Zndust�r;es and' all electri�ca`l . • wor':kgwi l l' "'be `ins.peated 'by,r.tfiat`{, t.2 -6G0) • ,, '" Permit No: M98 -0059 Status: ISSUED Applied: 03/20/1998 Issued: 04/14/1998 ACTIVITY NUMBER: PROJECT NAME: BOEING EMPLOYEES CREDIT UNION DEPARTMENT: Building Division Public Works, , ❑ Approved CORRECTION DETERMINATION: WR•ROUTE,DOC 1/98 PL? EV (.00t U T N ' C; SLIP M98 -0059 DATE: 3 -20 -98 F re re ention Strupl Planning Division ❑ OA- Vark\1 c6 Permit Coordinator up DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 3 -24 -98 Complete Incomplete n Not Applicable ❑ Comments: TUES /THURS ROUTING: Please Route ❑ No further Review Required Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 4 -7 -98 Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) El REVIEWERS INITIALS: DATE: F625 -052 -000 (8/97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY AA AF `_}; �"�F ^REGISTR,A2'IOI�T:�NUMBER. - , F CCAAAF COMFOP' O64D2 ,03'/21/1 i EFFECT,IVE DATEr° _'_ =� .� ::03/22/ COMFORT PLUS 6617 193RD OK STE P 105 KENT WA 98032 -2197 T h i s Payment Erb . 75 Total Fees: Total ALL Pmts: I3alance:. * * * *A *+4A * * *A4 S*A* 4 * *•kA h **A44* *A *•k * kA * * *•k * * ***A *A h A CITY OF TUKWILA, WA TRANSMIT ***4***** 4k** A**• 4 k 4kk** h• kA* k****** A** kk *1* * * * *,l** * *A TRANSMIT Number: R9700746 Amount: 80.75 04/14/98 16:02 Payment Method: CHECK Notation: COMFORr PLUS Init: 13LH Permit • No: M9f3 -0059 Type: f3 -MICH MECHANICAL. PERMIT Parr-el No: 2623Q4 -9075 Site Address: 655 ANDOVER Pt( W Location: BUILDING #7 t3tI.7 • 80.75 .00 **4r* *0 **0 A * *AAA*. * �•:I*** * * * *AA* k **•0 * 4. *A * 41% * * ** M. * •A *0**t4 Account Code Description Amou'nu 000/045.830 PLAN CHECK -- NONRES, 000/322.100 MECHANICAL •- NONRES • 17..75 7 1 . O 0 Project: � L l.k... �} Type of inspectl9 r/ } Address: ss Date called: Special in ructions: Date wanted: r l c (� 1,i b a.m. p.m. Requester: Phone No.: cvni$t^am_ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENT INSPECTION RECAP -D Retain a copy with plk. mit Corrections required prior to approval. • y \C -00.5 PERMIT NO. -O6) -431 -3670 I Inspecto Date: ( (0, 0 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. l Receipt No.: Date: Project: U.— Type of ins ectio . are' S-P-ogid OfrtoRez0 Address: !, 5 � 1 Date called: Z Special Instructions: W 6rt Date wanted: 5/2(/qk a. m. • Requester: �, Phone No.: ra INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 9818 Approved per applicable codes. COMMENTS: Inspector: (1 INSPECTION RECQRD Retain a copy with __;nit m..;.: n: uk x'• oxirr,"^'fi"e�i*,.a":£F,^,*' T'J'T' PERMIT NO. (206) 431 -3670 Corrections required prior to approval. 7 -- Fut C -. Date: S(lsn $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Receipt No.: Date: Project:f Type I action " Address!„ _ „/� \ J �' { Date called: .30.. Special instructions: 13 4 C A n •>j1 Date wanted: g 8 . _ -„ "✓ Requester: r' Ph( '' C'IO (42.s OZ INSPECTION NO. ' tr; nliY.. V& T. O�' N�+ tf'„ 7' nrra .M- '�- ..,,....✓..- ..- .r. --.- A„K,.. Approved per applicataldodes. i • Inspector: INSPECTION RECOpQ ( Retain a copy with pp &, Ait PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 (206) 431 -3670 COMMENTS: Corrections required prior to approval. Date` ,6/ $42.00 REINSPECTION''FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter,Blvd., Suite 100. Call to schedule reinspectlon. I Receipt No.: Date: COMMENTS: il 1.1 1 n: 1 L Type of Inspection: Address : at/ Iv b u 7 7* ..— — 64/14-411 Z ed eia.-2,, 4., / `.---, Requester: --) ato A c A CI ,•• 41 ,54 R — -re-e ( R.,?_____% e__________&, A..-"e--/ ,";.,.‘.. ,.. r .,•'■ ,It - --*..)/70 a Alt•"7 _Za;e2v2c Project: .. il 1.1 1 n: 1 L Type of Inspection: Address : at/ Iv b u 7 7* t tpje called: Special instructions: Date wanted: p.m. Requester: --) ato A c A CI Phone No.: ilAs-as ) -el 8 in 134ittiv I I INSPECTION REC,VET Retain a copy with ilJnit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100,' Tukwila, WA 98188 Vk Approved per applicable codes. Inspector: I I Je4--IP 9g_051 Corrections required prior to approval. Date: 171 PERMIT NO. 206) 431-3670 21-2-g $42.00 REINSPECV1ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: v'`Q is: •'�, . � � •'• ' v: w:::::::•;;}•.} v ::::v'•i:•:•i: }:• } }i:•i ^ ? ? ?M:p: (If( 4$ Balance Due: $ 6$.15 Need Current Contractor Registration Card: ❑ Yes Need to Enter Contractor Information in Sierra: ❑ Yes if No '‘ it" • 4. v,".• 9 Project Name Address tAl. Retain current inspection schedule M A ----- Needs shift inspection c' City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM - T)-.6)e-,A, z • . 7 6 /m o‘. / V 7- Approved without correction notice FINALAPP.FRM Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature F,U 372, Thomas P. Keefe, Fire Chief Permit No. 6'4:7 Date T.F.D. Form F.P. 85 John W. Rants, Mayor Suite # Headquarters Station: 444 Andover Park East • Tukwila, WathInton 98188 ,• Phone: (206) 575-4404 • Fie (206) 575-4439 [ GREENH CK DAMPERS AND LOUVERS Application and Design Model CFSD -23 is a combination fire smoke damper UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model's operational ratings, of up to 3000 fpm and 8" w.g., far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings — providing an extra measure of. safety. Model CFSD -23 is rated for air flow and leakage in either direction. Ratings Fire Resistance: Leakage: Pressure: Velocity: Temperature: Standard Construction Frame: 5 "x1" galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 17" high to maximize free area and performance. Blades: 16 ga, galvanized steel, reinforced with 3 longitudinal structurally designed vee's. Seals: Extruded silicone rubber blade seals. Flexible stainless steel jamb seals. Concealed in jamb. UL listed 165 °F. 1/2" dia. plated steel. Bronze sleeve type. Linkage: Fusible Link: Axles: Bearings: UL rating of 1 hour for corridor ceilings UL 555S leakage class I (to 8 in. w.g.) Leakage rated in both directions 8 in. w.g. - differential pressure Dynamic and operational rated to 3000 fpm. Rating is for airflow in either direction through damper. 350° with all actuators. Higher tempt.ratur' ratings with some actuators. Fire tested to 1800 °F. Size Limitations Minimum Size: 8" W x 6" H Maximum Size: 24" W x 24" H Optional Features: • Galvanized steel sleeves. • Stainless steel bearings • OCI (Open closed indication switches) • 212 °F fuse links (other temperatures available, consult Greenheck) • TOR (remote override of 165 °F closure. Allows damper to perform smoke management functions during a fire emergency.) • Electric or pneumatic actuators to accomplish smoke management and system functions. Corridor Ceiling FIRE SMOKE DAMPER H . C 'W & H dimensions furnished approximately 1 /4" undersize. Model CFSD -23 Steel 3 -V Blades UL 555S Leakage Class I Model CFSD -23 meets the requirements for corridor ceiling dampers, smoke dampers and combination fire /smoke dampers established by: National Fire Protection Association NFPA Standards 90A, 92A, 92B & 101 BOCA National Building Codes ICBO Uniform Building Codes SBCCI Standard Building Codes City of Los Angeles CSFM California State Fire Marshall Listing #: 3230 - 0981:105, 3230 - 0981:106 "UL CLASSIFIED (see complete marking on product)" "UL CLASSIFIED to Canadian safety standards (see complete marking on product)" Standard 555, 555S (Listing #R15439) CFSD -23 05-97 Qty W H Fusible Link Temp. Actuator Model A Dimension Sleeve CITY OF Length Ga. • MA R 2 0 1998 PERMIT CENTER Project Contractor Location Design Specifier Mie • 00,3 [ GREENH CK DAMPERS AND LOUVERS Application and Design Model CFSD -23 is a combination fire smoke damper UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model's operational ratings, of up to 3000 fpm and 8" w.g., far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings — providing an extra measure of. safety. Model CFSD -23 is rated for air flow and leakage in either direction. Ratings Fire Resistance: Leakage: Pressure: Velocity: Temperature: Standard Construction Frame: 5 "x1" galvanized steel hat channel with reinforced corners. A low profile head and sill are used on sizes less than 17" high to maximize free area and performance. Blades: 16 ga, galvanized steel, reinforced with 3 longitudinal structurally designed vee's. Seals: Extruded silicone rubber blade seals. Flexible stainless steel jamb seals. Concealed in jamb. UL listed 165 °F. 1/2" dia. plated steel. Bronze sleeve type. Linkage: Fusible Link: Axles: Bearings: UL rating of 1 hour for corridor ceilings UL 555S leakage class I (to 8 in. w.g.) Leakage rated in both directions 8 in. w.g. - differential pressure Dynamic and operational rated to 3000 fpm. Rating is for airflow in either direction through damper. 350° with all actuators. Higher tempt.ratur' ratings with some actuators. Fire tested to 1800 °F. Size Limitations Minimum Size: 8" W x 6" H Maximum Size: 24" W x 24" H Optional Features: • Galvanized steel sleeves. • Stainless steel bearings • OCI (Open closed indication switches) • 212 °F fuse links (other temperatures available, consult Greenheck) • TOR (remote override of 165 °F closure. Allows damper to perform smoke management functions during a fire emergency.) • Electric or pneumatic actuators to accomplish smoke management and system functions. Corridor Ceiling FIRE SMOKE DAMPER H . C 'W & H dimensions furnished approximately 1 /4" undersize. Model CFSD -23 Steel 3 -V Blades UL 555S Leakage Class I Model CFSD -23 meets the requirements for corridor ceiling dampers, smoke dampers and combination fire /smoke dampers established by: National Fire Protection Association NFPA Standards 90A, 92A, 92B & 101 BOCA National Building Codes ICBO Uniform Building Codes SBCCI Standard Building Codes City of Los Angeles CSFM California State Fire Marshall Listing #: 3230 - 0981:105, 3230 - 0981:106 "UL CLASSIFIED (see complete marking on product)" "UL CLASSIFIED to Canadian safety standards (see complete marking on product)" Standard 555, 555S (Listing #R15439) CFSD -23 05-97 ; ; ° s; .. 4 ; z : log '0 66 04 .03 02 a 0 mmn Co W3 e n n RCM I,otinq: el n $o o o • tmt9mmunum 1111•/g1 t1•tit9 uI •iiv111•u 11 ll MI•RIIIIIII � .iiii U111�if�i 11 11111 1 1 1111 11111 55 lif 5.2 III 5.3 III r.i_•i..■■ 119111111••.111INIM t9i it••0Iu1� i EMIIilil ®u1111 u _....... :w.:u. :E ■tMEHI . ®111111•/�flf�Muii1 IIPAPAe..1 ?; vi111�1�� %11111111 ■_�_..im. /J�/t_tiILIr /I // %M / _ ___::::: A•■•__.. MI/I__9111=1111111 / / = = iUll1 MIIIII ®,. 111111 t ll 111111111 1111 ..... Milli 1111 iii • fie 91 2 3 5 6 07891 PRESSURE DROP DATA CFSD -23 CONFIGURATIONS This pressure drop testing was conducted in accordance with AMCA Standard 500 using the three configurations shown. All data has been corrected to represent standard air at a density of .075 ib /ft Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. �A yi. k a 3 Damper Size 12" x 12" Velocity (torn) O 1 • Figure 5.3 Figure 5.2 Figure 5.5 10 9 9 7 6 5 4 3 2 t.9 .8 .7 .6 .5 .4 .3 .2 :8 .06 .07 .08 .05 .04 .03 .02 5D 513 p Damper Size 24" x 24" BD 5.5 52 5.3 4 6 678910 2 3 4 5 979910 x 100 8 1000 Velocity (fpm) D= - \/4(W) (H) V 3.14 6' CFSD -23 is available in 3 different configur below illustrate these different configuratio Configuration #1 - Fire Rated Actuator ( Fire Rated Ce ling r L 'H' 'H' H 0 - 1 F re Rated Ceiling Grille (by others Configuration #2 - Fire Rated Actuator ( r 1 j O L ----- ( Finished Ceiling Below Fire Rated Ceiling Grille (by others) Ceiling Configuration #3 - Fire Rate Actuator Actuator Space' Envelopes Siebe Landis & Staefa MA -220 Serie MA -230 Series 331 -4551 'X' Dimension 5.875" 7.5" Minimum Width 12" 13" (18 " w /options' Minimum Height 12" 18" 'A' = 'X' + Depth of Grille Consult factory if 'A' is greater than 9.5" r CONFIGURATIONS CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings - below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille I' r F re Rated Ceiling Fire Rated Ceiling Fie Rated Ceiling ' H ' 'H' H } 4 ..., ,..,,,,,,,..,...,,,,,,.....,.,,,,,..,,, Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling r L 0 T 5 — A Finished Ceiling Below rr Grille (by others) Grille (by others) T 'A' V F A 5" 'A' 43/4" Min. r Sleeve Length 16" Sleeve Length t. SPACE ENVELOPES 'Consult factory for dampers under 12" high. 1 Options include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or externally. 'A' Dimension Standard Minimum Sleeve Length With OCI, RRL, or TOR, H dimension less than 10" 11 3 /e" 20" All other dampers 7 Vie" 16" r CONFIGURATIONS CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings - below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille I' r F re Rated Ceiling Fire Rated Ceiling Fie Rated Ceiling ' H ' 'H' H } 4 ..., ,..,,,,,,,..,...,,,,,,.....,.,,,,,..,,, Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling r L 0 T 5 — A Finished Ceiling Below rr Grille (by others) Grille (by others) T 'A' V F A 5" 'A' 43/4" Min. r Sleeve Length 16" Sleeve Length t. SPACE ENVELOPES 'Consult factory for dampers under 12" high. 1 Options include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or externally. 'A' Dimension Standard Minimum Sleeve Length With OCI, RRL, or TOR, H dimension less than 10" 10 20" All other dampers 6 16" r CONFIGURATIONS CFSD -23 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings - below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille I' r F re Rated Ceiling Fire Rated Ceiling Fie Rated Ceiling ' H ' 'H' H } 4 ..., ,..,,,,,,,..,...,,,,,,.....,.,,,,,..,,, Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling r L 0 T 5 — A Finished Ceiling Below rr Grille (by others) Grille (by others) T 'A' V F A 5" 'A' 43/4" Min. r Sleeve Length 16" Sleeve Length t. SPACE ENVELOPES 'Consult factory for dampers under 12" high. 1 Options include OCI, RRL, TOR, etc. 2 Consult factory for optional motors on units 18" x 18" or larger. Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or externally. SPECIFICATIONS Corridor Ceiling Fire Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans, and /or as described in schedules. Dampers shall be classified by UL under the "Corridor Damper" listing with a fire resistance rating of 1 hour and shall further carry a leakage Class I rating under UL 555S. Each damper /actuator combination shall have a UL555S elevated temperature rating of 350 °F minimum and shall be operational and dynamic rated to operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specifier select one of the following) electric type for 24 Vac or 120 Vac operation OR pneumatic type for 20 psi operation. CFSD -23 Damper blades shall be 16 ga. galvanized steel 3 Vee type with three longitudinal grooves for reinforcement. Damper frame shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be sintered bronze sleeve type turning in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tight seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Each damper shall be supplied with a 165 °F fusible link. The basis of design is Greenheck Model CFSD -23. f3GREENHECK MAR 20 '98 16:2S HUDSON AND ASSOC RICHARD HUDSON & AvLUQATEB, ma. CONSULTING ENGINEERS 1805 12TH AVENUE • SUITE 18 SEATTLE, WASHINGTON 98122 206-324-6160 1 . • aoe SoUT44 C ( s CALCULATED BY 4 SHUT ko. FILE COPY : 1) 141€' ooq'i CORPoRWrE. $QtARE OF W P.2- MAR Ee '98 16129 HUDSON AND ASSOC P.3 tvr4 ` . . , rsmirt c poRATZ RICHARD HUDSON &'AbSOCIATE8, INC. JOE CONSULTING ENGINEERS env NO, OF 1605 12TH AVENUE • SUITE 18 CALCULATED ay 04+ DATE 3 - (20 "`145 SEATTLE, WASHINGTON 98122 2061.324 -8160 1 1 R• T; V, • I— i Q � I —4— I t I 1 I 1 �r �•� _ •_.. I —• I ■ I T I J I I I I I 1 I I I 1 i i I i I I , :._. -.1.. • ! r I I _1... I. L_. L__J._��..__o_...._I..._..1.__! ..!.__..�.._..`_ • i —r_ • 1 I I 1 , 1� � I • ■ I I . �._.. I I , - I I , 1 I , , I ■ I I • I I , I ' I I I 1 I ' I I 1 ' • I I I 1 I I ., , 1 i _. _.... ..... 1 .�... _..._�._.. I 1 1 I i I I I .... 1 i , i i 1 1' I ; ' ....t---7-1— ' ' 1 ' 1 I i f ! 1 ! i. 1 I r I I ° ' 1 .1» - wQ __ v,1 q. 00e:1 �1'1.1?i_VB .l . 5..�___. Iff� • I I I I I ( I ! I I _ I i I.__..F, �__'I_- ......�_ I 1 1 I 1 1 I 1 1 I 1 I 1 I I I J._..... '�L� I I } . i I I I �' I • I I I 1 1 I 1 i I • 1 • • 1 ! 1 I ! I ■ 1 1 1 ' I i 1 i �l "7�: I x 12 ,_•_• -•- ` - -; I _ ' i ._^� I ' ' , ' I I I I ' 1 I 1 le' 416 4 r I • 1. I i I � I MAR 2,3 1995 PERMIT CENTEP PROJECT Corporate Square LOCATTON Tukwila, WA CONTRACTOR Comfort Plus PRODUCTS Fan powered terminal units Air Commodities Inc. r HEATING • VENTILATING • AIR CONDITIONING EQUIPMENT Submittal Corporate Square EQUIPMENT PROVIDED [Titus By: Matthew Rybar March 2, 1998 Mee 0 P pp� 1Gp CITRECEIVED UWILA MAR 2 0 1998 PERMIT CENTER 6100 Sixth Avenue South, Seattle WA 98108 • (206) 767.2600 • Fax; (206)767 -4815 • 1-800-875-2473 www.air- commodities.com Unit Size Inlet Size A B C D E F G SPflert, J I K fAilt M N lititti Filter Size 2.7 6 4 '/. 6.4 2.7 2.0 5 '/2 9.8 5 3.0 6 e/. 18,0 7.5 5.6 2, 3 8 11 10 2 '/2 2 7 16 '/. 3 14 6 '/a 12 31 20 1 '/2 39 22 x 14 10 7 'h 8 6 '/a 4, 5 10 16 13 2 '/ 2 8 '/a 18 'I. 4 '/2 17 7'/2 15 32 25 '/a 1 '/: 47 27 X 17 12 8 , 14 9 10 7 6 12 20 15 2 '1a 2 9 'la 20 '/4 5 '/a 19 8 '/ 17 34 '/: 25 '/: 1 '/: 51 27 x 19 14 9 '/: 16 10 ' /a All dimensions are in inches. Filter size Is for unit without attenuator For filter size with attenuator, please see reverse side. Unit Size Motor Horse- power Motor Amperage Ratings 120/1/60 208/240/1/60 277/1/60 FLA FLA FLA 2 ' /,0 2.6 1.1 0.8 3 '/a 6.4 2.7 2.0 4 '/. 6.4 2.7 2.0 5 '/2 9.8 4.0 3.0 6 e/. 18,0 7.5 5.6 TITUS® Submittal Terminal Units • Fan Powered • Parallel Type Model: PMFV • Pressure Independent • Pneumatic Controls D h A I — 5 - 1 G C Beckdraft Damper Control Enclosure. (Omitted when electric coil is furnished.) 1 -� — 12 —+-^— F Induced Air 3 3/8 E Access Panel (Entire Bottom is Removeable) Primary ; Air Fitter (Optional) Metal Controller Cover (Optional) Nominal Inlet Size Minus 1/8 FLA = Full Load Amperage, as tested in accordance with UL 1995. All fan motors are single phase, same voltage as electric coil (when supplied), with exception that 277 voltage motors are used with 480 volt / 3 phase coil (4 wire wye). Dimensions are in inches. (Please see reverse side.) I FP- PMFV -1.0 5 -1 -95 Accessories (Optional) Check [' if provided. o TITUS II Controller maintains constant reset span and start point, regardless of changes to HI and LO cfm limits. • Induced air filter, 1" thick, disposable construction type. Fan disconnect switch (not ava ❑ ( tidirlfeKwmp, units with optional electric ditlie{. O ❑ Metal controller cover. r 19 98 ❑ Hanger brackets. �►AR G • Micro -LocT Liner. PERMIT CENTER 0 FP -1.0 -s Unit Size AA BB CC Filter Size 2, 3 21 12 12 ( 2 ) 1 2 1 2 x 1 0 4, 5 26 '/z 15 15 (2) 15 x 12 6 26 'h 17 15 (2) 17 12x 12 Unit Size R' S• T 1 Row Coil 2 Row Coil X X 2, 3 19 12 12 3 /4 2 3 4, 5 24 '/z 15 1 2 3 6 24 12 17 '/2 '/. 2 3 Unit Size R' S• 2, 3 11 10 4, 5 16 13 6 20 15 Submittal FP- PMFV -1.0 5 -1 -wd Accessories (Optional) Check ® If provided ❑ Hot Water Coil Section All dimensions are in inches. Standard Features • ' /z" copper tubes. • Aluminum ripple fins, 10 per inch. • Connections: Male solder, 1- row' /z", 2 -row s /a ". Right hand only. • Galvanized steel casing. • Flanged duct connection. • Coil is installed at induced air inlet. Coil Rows ❑ 1 -Row ❑ 2 -Row 1 /2 Check [f if provided. • Note: R and S are inside dimensions. ❑ Electric Coil Section All dimensions are in inches. Standard Features • Automatic reset thermal cutouts, one per element. • Single point electrical connection for entire unit, including coil. • Positive pressure air flow switch. • Flanged duct connection. • Coil is installed at discharge of unit. General Description • Heavy steel casing, with leak resistant construction. • Dual density insulation, coated to prevent air erosion, meets requirements of NFPA 90A and UL 181. • Bottom access panel can be removed for service. TITUS® Note: Coil control box replaces stan- dard terminal unit control box. Options Check ® Selection ❑ Mercury contactors. ❑ Fuse block. ❑ Disconnect switch, door interlock type. ❑ Manual reset cutout. ❑ Dust tight construction. a 1 Dts- cfunge I Alr SFlowM 2 V2 L- 1 u9 Supply Voltage Check ® Selection 0208 V, 1 ph, 60 Hz. 0240 V, 1 ph, 60 Hz. 0277 V, 1 ph, 60 Hz. 0208 V, 3 ph, 60 Hz. 0480 V, 3 ph, 60 Hz (4 wire wye). • Note: R and S are inside dimensions. ❑ Induced Air Inlet Attenuator All dimensions are in inches. + eB 1+--AA —J —11 LccJ • Energy efficient fan motor, permanent split capacitor type, mounted in vibration isolators. • Adjustable SCR fan speed control, with minimum voltage stop. • Pressure independent primary air flow control. • Multipoint Inlet velocity sensor with center averaging. • Primary air flow balancing connections. • Single point electrical connections. • Rectangular discharge operkig..44tOned for flanged duct connection OF TUKWILA Note: This submittal Is meant to demonstrate general dimensions of this protkrct The drawing on this submittal are not meant to detail F P -� 0-S aspect of the product with exactness. Drawtrtgs are not to sale. TITUS MOMS the nght to make changes without written notice. 990 Security Row • Richardson, Texas 75081 • 214-699-1030 • Fax 214-644-4953 PERMIT CENTER Al nom i I W 4 Ne pet of the root entry a ,eptOduced or rwmeof in tiny tom w wry mr•, eMi••"e or mamma raw.; MrooMI•W and .••wane wW wN idsnnre Wings newel •yewm wMN pw•m••• n mime Ya" Tw,•.v YywtL Yt . Unit Size Inlet Size A B C D E F I G 2 J K Zga M N iilli Filter Size 2.7 6 4 1 /4 6.4 2.7 2.0 5 1 /2 '/i 9.8 5 '/z 3.0 6 3 /, 18.0 7.5 5.6 2, 3 8 11 10 2' /2 2 7 5 '/. 3 14 6 1 /2 12 31 20 1 '/z 39 '/2 22 x 14 10 7 1 /2 7 '/: 8 5'A 6'/: 4, 5 16 13 2 2 8 '/z 4 '/2 17 8 15 32 25 1 /2 1 47 27 x 17 12 7 , ,/2 14 9'/. 9' /z 10 7 '/. 7 6 12 20 15 2 '/z 2 9 '/: 7 " 5 '/z 19 8 '/z 17 34 25 '/2 1 '/z 51 27 x 19 14 9 V. 9 1 /: 16 9 '/. 10 V: All dimensions are In inches. Filter size is for unit without attenuator For fitter size with attenuator, please see reverse side. Unit Size Motor Horse- power Motor Amperage Ratings 120/1/60 208/240/1/60 277/1/60 FLA RA FLA 2 ' /,. 2.6 1.1 0.8 3 '/• 6.4 2.7 2.0 4 1 /4 6.4 2.7 2.0 5 '/i 9.8 4.0 3.0 6 3 /, 18.0 7.5 5.6 �✓ 4111■1li•t16' TITUS® Submittal 11111111111111111111. Terminal Units • Fan Powered • Parallel Type Model: AMFV • Pressure Independent • Analog Electronic Controls Dimensions are in inches f—B-1 I It GJL. Backdraft Damper 26(Without Electric Coil) 18(With Electric Coll) L-1 Control Enclosure Filter (Optional) a Idced Primary Air f --I 1-3 3/8 _ Access Panel (Entire Bottom is Removeable) • FLA = Full Load Amperage, as tested in accordance with UL 1995. All tan motors are single phase, same voltage as electric coil (when supplied), with exception that 277 voltage motors are used with 480 volt / 3 phase coil (4 wire wye). (Please see reverse side.) f FP- AMFV -1.0 10 -1 -95 Nominal Inlet Size Minus 1/8 Accessories (Optional) Check [if if provided. ❑ Induced air filter, 1" thick, disposable con- struction type. ❑ Fan Unit Fusing ❑ Fan disconnect switch (not available on units with optional electric coils). ❑ Micro-Loom" Insulation. ❑ Hanger Brackets. CITY or RECEIVED A MAR 2 0 1998 PERMIT CENT .9 0-S Unit Size AA BB CC Filter Size 2,3 21 12 12 (2) 12'/2x10 4, 5 26 '/t 15 15 (2) 15 x 12 6 26 '/t 17 15 (2) 17 '/z x 12 Unit Size R• S• T 1 Row Coil I 2 Row Coil X X 2, 3 19 12 '/z 3 /. 2 I 3 4. 5 24 '/t 15 1 2 j 3 6 24 1 /2117 '/2 2 / 4 2 3 Unit Size R• S' 2, 3 11 10 4, 5 16 13 6 20 15 Submittal FP- AMFV -1.0 10-1 -9 Accessories (Optional) Check ® if provided ❑ Hot Water Coil Section All dimensions are in inches. Standard Features • ' /t" copper tubes. • Aluminum ripple fins, 10 per inch. • Connections: Male solder, 1- row' /z ", 2 -row 2 /4". Right hand only. ❑ Electric Coil Section All dimensions are in inches. Standard Features • Automatic reset thermal cutouts, one per element • Single point electrical connection for entire unit, including coil. • Positive pressure air flow switch. • Ranged duct connection. • Coil is installed at discharge of unit. ❑ Induced Air Inlet Attenuator All dimensions are in inches. General Description • Heavy steel casing, with leak resistant construction. • Dual density insulation, coated to prevent air erosion, meets requirements of NFPA 90A and UL 181. • Bottom access panel can be removed for service. • Energy efficient fan motor, permanent split capacitor type, mounted in vibration isolators. Note: This submittal is meant to demonstrate general dimensions of this product. The drawing on this submittal are not meant to d411ftaii CEN 9.0 -S aspect of the product with exactness. Drawings are not to sale. TTTUS reserves the right to male cnames winout written notice. 990 Security Row • Richardson, Texas 75081 •214699.1030 • Fax 214-644-4953 N ,yr a••d. W poi el IM won 'my a npaduso• r •ru•.eo• n et./ loin et wry MEW rovrnc •s nreuwcri v q Oftloc.,•, W iwoq r Ivy wr ••••u••n amp ,* .U.v rrsul M.••r•w w mina Yon T•Uwc Meru Mt TITUS® • Galvanized steel casing. • Flanged duct connection. • Coil is installed at induced air inlet. Note: Coil control box replaces standard ter- minal unit control box. Options Check WI Selection ❑ Mercury contactors. ❑ Fuse block. ❑ Disconnect switch, door interlock type. ❑ Manual reset cutout. ❑ Dust tight construction. 112 s n._J L� --J x L a � 1 � t L t e. a' Viz Coil Rows Check 21 if provided. ❑ 1 -Row ❑ 2 -Row • Note: R and S are inside dimensions. D. i charge Air S Flow I Supply Voltage Check ® Selection 0208 V, 1 ph, 60 Hz. 0240 V, 1 ph, 60 Hz. 0277 V, 1 ph, 60 Hz. 0208 V, 3 ph, 60 Hz. 0480 V, 3 ph, 60 Hz (4 wire wye). • Note: R and S are inside dimensions. • Single point electrical connections. • Rectangular discharge opening is designed for flanged duct connections. • Adjustable SCR fan speed control, with minimum voltage stop. • Pressure independent primary air flow control. • Electronic proportional room thermostat with adjustable temperature setpoint Is included RECEIVED with unit. CfIy OF VOILA • Minimum and maximum air flow adjustments are made at the room thermostat, using a digital voltmeter. ma 0 1998 CO O. s^0 TITUS® Models: PMFV, AMFV, DMFV • Fan Performance vs. Downstream Static Pressure • Induction Side u 600 550 500 450 400 350 300 250 200 150 100 50 2000 1800 1600 1400 1200 1000 u 800 600 400 200 Unit Size 2 t Static Pressure - Inches Unit Size 5 of Water D1 7' MIN 0 0.0 0.1 0.2 0.3 0.4 0.5 0 6 Static Pressure - Inches of Water Fan Powered Terminals > Performance Dala 800 750 700 650 600 u. 550 u 500 450 400 350 0 300 0.0 0.1 0.2 0.3 0.4 0.5 0 6 0 0 0 1 0 2 0 3 0 4 0 5 0 6 2200 2100 2000 1900 1800 1700 u . 1600 1500 1400 1300 1200 1100 No Coil or Electric Coil 1 Row Water Coil 2 Row Water Coil Unit Size 3 Static Pressure - Inches of Water Unit Size 6 MAX • MIN 00 0.1 0.2 03 04 0.5 06 Static Pressure - Inches of Water 2 u 1400 1300 1200 1100 1000 900 800 700 600 500 400 55 oo, Unit Size 4 00 01 0 03 04 05 06 Static Pressure - Inches of Water CITY OF vim 2 0 1998 PERMIT CENTER 6 16 1600 - - 20 23 30 34 38 41 2000 • 20 24 27 33 37 42 44 2600 20 25 29 32 37 41 45 47 3200 24 28 33 35 40 44 48 50 4000 28 32 37 39 43 47 51 53 4.5.6 12 900 - - - - 23 27 31 33 1100 - - 20 22 25 29 33 36 1400 - 20 24 26 29 33 37 39 1800 20 24 28 31 32 36 40 42 2000 22 26 30 33 33 37 41 43 4-5-6 14 1200 - - 4 20 27 31 35 37 1600 • - 23 25 30 35 39 41 2000 - 22 27 29 33 37 42 44 2400 22 26 30 32 36 40 44 46 3000 25 30 34 36 39 43 47 49 2-3 4-5 6 10 600 - - 4 - - 21 25 27 800 • - - 20 21 25 29 31 1000 • - 22 24 24 28 32 34 1200 - 21 25 28 27 31 34 37 1400 20 24 28 30 29 33 37 39 2-3 4-5 8 350 • - 4 - - - - 21 400 • - - • - • 20 23 500 • - - 9 10 • 23 26 700 - 21 21 23 20 24 28 30 800 - - 23 26 22 26 30 32 • 2 -3 6 225 • -. 4 - - - - - 300 • - - • 1.0" I 2.0" I 3.0" 20 400 - - Room Effect 9 10 • 21 24 450 - 21 - 21 • - 23 25 _ 500 - - 21 23 . 14 20 24 27 Sound Noise Criteria (NC) Radiated Attenuation Values • Unit Size inlet Size cfm 4 Discharge 6 Radiated Environ. Effect A Ps 2 A Ri 0.5" ] 1.0" 12.0" I 3.0" 0.5" 1.0" I 2.0" I 3.0" S42 TITUS® c E 0. a Fan Pow. f Terminals > Performance Data ' IO3f) 0,5 ')'.)h Models: PMFV, AMFV, DMFV • Application Data • NC Values 100% Primary Air > . P Is the difference in static pressure from inlet to discharge. > Dash (•) in space denotes NC value less than 20. > All sound data are based upon tests conducted in accordance with ARI 880-94, Application data are based upon factors found in ARI Standard 885-90: > Ceiling type • mineral fiber, 5/8 in. -35 lb./ cu. ft. ■ Room size • 3,000 cu. ft.. 10 ft. from the source Application data are based upon factors found in ARI Standard 885.90: > End reflection • 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 In. thick duct lining > Room size • 3.000 cu. ft.. 10 ft. from the source > For complete information on calculation of NC levels. refer to catalog pages C85 -C77, The following dB credits per octave band have been used In the calculations of NC values shown above, for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction (dB) 0 3 6 8 10 11 CITY OFETUKWILA MAR 2 0 199E PERMIT CEN'IEs Radiated Attenuation Values • Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 Ceiling Effect 9 10 12 14 15 15 Room Effect 9 10 11 12 13 14 Total d8 reduction 21 22 24 27 29 30 S42 TITUS® c E 0. a Fan Pow. f Terminals > Performance Data ' IO3f) 0,5 ')'.)h Models: PMFV, AMFV, DMFV • Application Data • NC Values 100% Primary Air > . P Is the difference in static pressure from inlet to discharge. > Dash (•) in space denotes NC value less than 20. > All sound data are based upon tests conducted in accordance with ARI 880-94, Application data are based upon factors found in ARI Standard 885-90: > Ceiling type • mineral fiber, 5/8 in. -35 lb./ cu. ft. ■ Room size • 3,000 cu. ft.. 10 ft. from the source Application data are based upon factors found in ARI Standard 885.90: > End reflection • 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 In. thick duct lining > Room size • 3.000 cu. ft.. 10 ft. from the source > For complete information on calculation of NC levels. refer to catalog pages C85 -C77, The following dB credits per octave band have been used In the calculations of NC values shown above, for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction (dB) 0 3 6 8 10 11 CITY OFETUKWILA MAR 2 0 199E PERMIT CEN'IEs Discharge Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 End Reflection 11 6 2 0 0 0 Duct Lining 1 3 8 21 20 12 5', 8" Flex Duct 6 10 17 19 19 12 Room Effect 9 10 11 12 13 14 Total dB reduction 30 31 39 53 53 39 S42 TITUS® c E 0. a Fan Pow. f Terminals > Performance Data ' IO3f) 0,5 ')'.)h Models: PMFV, AMFV, DMFV • Application Data • NC Values 100% Primary Air > . P Is the difference in static pressure from inlet to discharge. > Dash (•) in space denotes NC value less than 20. > All sound data are based upon tests conducted in accordance with ARI 880-94, Application data are based upon factors found in ARI Standard 885-90: > Ceiling type • mineral fiber, 5/8 in. -35 lb./ cu. ft. ■ Room size • 3,000 cu. ft.. 10 ft. from the source Application data are based upon factors found in ARI Standard 885.90: > End reflection • 8 in. termination > Flex type • vinyl core flex > 5 ft. of 1 In. thick duct lining > Room size • 3.000 cu. ft.. 10 ft. from the source > For complete information on calculation of NC levels. refer to catalog pages C85 -C77, The following dB credits per octave band have been used In the calculations of NC values shown above, for 300 cfm flow division. Inlet Size 6 8 10 12 14 16 Reduction (dB) 0 3 6 8 10 11 CITY OFETUKWILA MAR 2 0 199E PERMIT CEN'IEs 2 300 28 - 350 30 - 400 31 - 450 32 - 500 33 - 520 33 - 4 600 31 - 700 32 - 800 33 - 900 33 - 1000 34 - 1150 35 - 3 475 28 - 500 29 - 525 29 - 550 30 - 600 31 - 650 32 - 6 1250 34 - 1350 35 - 1500 36 - 1650 37 - 1800 39 - 2100 41 21 5 800 30 - 900 32 - 1100 35 - 1300 37 - 1500 39 - 1800 42 _ 21 TITUS® Models: PMFV, AMFV, DMFV ■ Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in. -35 lb./ cu. ft. > Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 In. termination • Flex type - vinyl core flex > 5 ft. of 1 in. thick duct lining > Room size - 3,000 cu. ft., 10 ft, from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels, refer to catalog pages C65 -C77. 4 1946 056 196 cm( Ot: ETUtCWII Ma 2 p 1998 P CENTER S43 coa GCS a C- 0.2 0 CL- = cv W Fan NC Levels Size cfm Rad. Disc. 6 7 NC NC TITUS® Models: PMFV, AMFV, DMFV ■ Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in. -35 lb./ cu. ft. > Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 In. termination • Flex type - vinyl core flex > 5 ft. of 1 in. thick duct lining > Room size - 3,000 cu. ft., 10 ft, from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels, refer to catalog pages C65 -C77. 4 1946 056 196 cm( Ot: ETUtCWII Ma 2 p 1998 P CENTER S43 coa GCS a C- 0.2 0 CL- = cv W Radiated Attenuation Values Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 Ceiling Effect 9 10 12 14 15 15 Room Effect 9 10 11 12 13 14 Total dB reduction 21 22 24 27 29 30 TITUS® Models: PMFV, AMFV, DMFV ■ Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in. -35 lb./ cu. ft. > Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 In. termination • Flex type - vinyl core flex > 5 ft. of 1 in. thick duct lining > Room size - 3,000 cu. ft., 10 ft, from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels, refer to catalog pages C65 -C77. 4 1946 056 196 cm( Ot: ETUtCWII Ma 2 p 1998 P CENTER S43 coa GCS a C- 0.2 0 CL- = cv W Discharge Attenuation Value: Octave Bands 2 3 4 5 6 7 Environ. Effect 3 2 1 1 1 1 End Reflection 11 6 2 0 0 0 Duct Lining 1 3 8 21 20 12 5 ', 8" Flex Duct 6 10 17 19 19 12 Room Effect 9 10 11 12 13 14 Total dB reduction 30 31 39 53 53 ` 39 TITUS® Models: PMFV, AMFV, DMFV ■ Application Data • NC Values (Fan Only) Fan Powered Terminals > Performance Data Application data are based upon factors found in ARI Standard 885 -90: > Ceiling type - mineral fiber, 5/8 in. -35 lb./ cu. ft. > Room size - 3,000 cu. ft., 10 ft. from the source Application data are based upon factors found in ARI Standard 885-90: > End reflection - 8 In. termination • Flex type - vinyl core flex > 5 ft. of 1 in. thick duct lining > Room size - 3,000 cu. ft., 10 ft, from the source The following dB credits per octave band have been used in the calculations of NC values shown above, for 300 cfm flow division. Unit Size 2 3 4 5 6 7 Reduction (dB) 0 5 6 8 9 10 > Dash ( -) in space denotes NC level less than 20. > All NC values are based upon 0.25 in. downstream static pressure. > All sound data are based upon tests conducted in accordance with ARI 880-94. > For complete information on calculation of NC levels, refer to catalog pages C65 -C77. 4 1946 056 196 cm( Ot: ETUtCWII Ma 2 p 1998 P CENTER S43 coa GCS a C- 0.2 0 CL- = cv W 6 16 1600 0.029 67 70 73 75 77 64 66 69 72 74 53 56 59 61 64 46 48 51 53 56 41 43 45 47 49 37 39 41 43 44 71 73 76 78 80 67 70 73 75 78 57 59 62 65 67 49 51 54 56 59 44 46 48 50 52 39 41 43 45 47 74 76 79 81 84 71 73 76 79 81 60 63 66 68 70 52 54 57 59 62 47 49 51 53 55 42 44 46 48 49 76 78 81 83 86 73 75 78 81 83 62 65 67 70 72 54 56 59 61 64 49 51 53 55 57 43 45 47 49 51 2000 0.045 2600 0.076 3200 0.115 4000 0.180 4 -5 6 14 1200 0.029 64 68 70 72 74 61 64 66 68 71 51 54 57 59 61 45 48 51 52 55 38 41 43 44 46 34 37 39 40 42 68 71 73 75 78 64 67 70 72 74 54 58 60 62 65 48 51 53 55 57 41 44 46 48 50 37 39 41 43 45 71 74 77 79 81 68 71 73 75 78 58 61 63 65 68 50 53 56 57 60 45 47 49 51 53 39 42 44 45 47 73 76 79 81 83 70 73 75 77 80 60 63 65 67 70 52 55 57 59 61 47 49 51 53 55 41 43 45 47 49 1600 0.052 2000 0.081 2400 0.117 3000 0.183 2-3 4-5 8 350 0.040 54 55 58 61 63 46 48 50 54 56 41 42 45 49 50 36 38 40 44 45 27 28 30 34 35 23 25 26 29 30 57 58 61 64 66 50 51 54 57 59 44 46 48 52 53 39 41 43 47 48 30 31 34 37 38 26 27 29 32 33 60 61 64 68 69 53 55 57 61 62 47 49 51 55 57 43 44 46 50 51 33 35 37 40 41 28 30 31 34 36 62 63 66 69 71 55 57 59 63 64 49 51 53 57 59 44 46 48 52 53 35 37 39 42 43 30 31 33 36 37 400 0.052 500 0.081 700 0.158 800 0.207 2-3 6 225 0.064 49 52 56 57 58 41 44 47 49 50 38 41 45 46 47 35 38 41 42 43 23 26 29 30 31 19 22 24 25 26 53 56 59 60 61 44 48 51 52 53 41 45 48 49 50 38 41 44 45 46 26 29 32 33 34 22 24 27 28 29 56 59 62 64 65 48 51 54 56 57 44 48 51 52 53 41 44 47 48 49 30 32 35 36 37 24 27 29 31 31 58 61 64 66 67 50 53 56 58 59 46 50 53 54 55' 42 45 49 50 51 32 34 37 38 39 26 28 31 32 33 300 0.114 400 0.202 450 0.256 500 0.316 4-5 6 12 900 0.035 62 64 67 69 70 57 60 62 65 66 49 51 54 57 58 43 45 47 50 51 36 37 40 42 43 32 33 35 38 38 65 67 70 73 74 61 63 66 68 69 52 54 57 60 61 46 48 50 53 54 39 41 43 45 46 34 36 38 40 41 69 71 73 76 77 64 66 69 72 73 55 58 60 63 64 49 51 53 56 57 42 44 46 48 49 37 38 40 43 43 71 73 75 78 79 66 68 71 74 75 57 60 62 65 66 51 53 55 58 59 44 46 48 50 51 38 40 42 44 45 1100 0.053 1400 0.085 1800 0.141 2000 0.174 2 -3 4.5 6 10 600 0.038 59 62 64 66 67 53 56 59 61 62 46 49 51 53 55 40 43 45 47 49 32 35 37 39 40 28 31 32 34 35 62 65 67 69 71 56 59 62 64 66 49 52 55 57 58 43 46 48 50 52 35 38 40 42 43 31 33 35 36 38 65 68 70 72 74 59 63 65 67 69 52 55 58 60 62 46 49 51 53 55 38 41 43 45 46 33 36 37 39 40 67 70 72 74 76 61 64 67 69 71 54 57 60 62 64 48 51 53 55 57 40 43 45 47 48 35 37 39 40 42 800 0.068 1000 0.107 1200 0.154 1400 0.209 Inlet Pri. Min. Sound Power @ .5" A P Size cfm A Ps 2 3 4 5 6 7 6 400 0.200 61 59 50 46 34 28 8 700 0.160 66 66 54 49 39 33 10 1100 0.130 70 72 58 51 43 37 12 1600 0 140 73 77 60 54 46 41 14 2100 0.120 76 80 63 55 48 43 16 2800 0.200 79 85 65 57 51 45 Unit Size Inlet Size cfm Min. A P Primary Air • Sound Power Octave Bands 0.5 "A P 1.0 ".. P 2.0 "A 15 3.0 "A P 2 1 3 1 4 5 6 1 7 2 3 1 4 1 5 1 6 1 7 2 1 3 1 4 5 617 2 3141 51617 cc c. ma cu oa cm- oa S44 TITUS® Fan Powered Terminals > Performance Data 1946 4,4 ,5 1996 Models: PMFV, AMFV, DMFV • Radiated Sound Power Levels • 100% Primary Air ARI Certification Rating Points > Min. 1 P is the lowest static pressure difference (damper wide open). > Radiated sound power is the noise transmitted through the casing walls. > Sound power levels are in decibels, re 10' watts. > All sound data are based upon tests conducted in accordance with ARI 880.94, Note: Ratings in accordance with ARI Standard 880-94 and certified to ARI. A Participating Corporation in the ARI 880 Certification Program RECE -ro or( OF MAR 2 0 1998 pa w- OENTER 4-5 6 12 900 0.035 62 61 59 55 52 47 65 65 62 58 55 50 69 69 66 61 58 53 71 71 68 63 60 54 1100 0.053 65 64 61 58 54 49 68 68 65 61 57 52 72 72 69 64 60 55 74 74 71 66 62 57 1400 0.085 68 68 65 61 56 52 72 72 68 64 60 55 75 75 72 67 63 58 77 77 74 69 65 59 1800 0.141 72 72 68 65 59 55 75 75 72 68 63 58 79 79 75 71 66 61 81 81 77 73 68 62 2000 0.174 73 73 69 66 60 56 77 77 73 69 64 59 80 81 77 72 67 62 82 83 79 74 69 64 2-3 4.5 6 10 600 0.038 57 57 53 49 47 41 60 60 57 53 50 44 63 64 60 57 53 47 65 66 62 59 55 49 800 0.068 61 61 57 54 50 44 64 65 61 57 53 47 67 68 64 61 56 50 69 70 66 63 58 52 1000 0.107 64 64 60 57 52 47 67 68 64 60 55 50 71 72 67 64 58 53 72 74 69 66 60 55 1200 0.154 67 67 63 59 54 49 70 71 66 63 57 52 73 74 70 67 60 55 75 76 72 69 62 57 1400 0.209 69 , 70 65 62 55 51 72 73_68 65 59 54 75 77 72 69 62 57 77 79 74 71 64 59 2 -3 6 225 0.064 43 45 40 39 34 28 47 49 43 43 37 31 51 53 46 46 40 33 53 55 48 48 42 35 300 0.114 47 50 44 44 37 31 51 53 47 47 40 34 55 57 50 50 43 37 57 59 52 52 45 38 400 0.202 51 54 48 48 40 35 55 58 51 51 43 37 59 61 54 55 46 40 61 63 56 57 48 42 450 0.256 53 56 49 49 41 36 57 59 52 53 44 39 60 63 56 56 47 41 62 65 58 58 49 43 500 0.316 55 57 51 51 42 37 58 61 54 54 45 40 62 64 57 58 48 43 64 67 59 60 50 44 6 16 1600 0.029 69 68 68 61 60 55 72 72 71 64 63 58 76 75 74 67 66 60 78 77 76 69 68 62 2000 0.045 72 71 71 64 62 57 76 75 74 67 65 60 79 79 77 70 68 63 81 81 79 72 70 65 2600 0.076 76 75 74 68 65 60 80 79 77 71 68 63 83 83 81 74 71 66 85 85 82 76 73 68 3200 0.115 79 78 77 71 67 63 83 82 80 74 70 66 86 86 83 77 73 69 88 88 85 79 75 70 4000 0.180 83 82 79 74 69 65 86 85 83 77 72 68 89 89 86 80 75 71 91 91 88 82 77 73 2-3 4.5 8 350 0.040 49 50 45 44 40 34 53 54 49 47 43 37 56 57 52 51 46 40 58 59 55 52 48 42 400 0.052 51 52 47 46 41 36 55 56 51 49 44 39 58 59 54 52 47 42 60 61 56 54 49 43 500 0.081 54 56 50 49 44 38 58 59 54 52 47 41 61 63 57 56 50 44 63 65 59 58 52 46 700 0.158 59 61 55 54 47 42 62 64 58 57 50 45 66 68 62 60 54 48 68 70 64 62 55 50 800 0.207 61 63 57156 49 44 64 66 60 59 52 47 68 70 64 62 55 50 70 72 66 64 57 51 4.5 6 14 1200 0.029 66 65 63 58 56 51 69 68 67 61 60 54 73 72 70 64 63 57 75 74 72 66 65 58 1600 0.052 70 69 67 62 59 55 73 73 71 65 62 57 77 76 74 68 66 60 79 78 76 70 88 62 2000 0.081 73 73 70 65 61 57 76 76 73 68 65 60 80 80 77 71 68 63 82 82 79 73 70 64 2400 0.117 75 75 72 68 63 59 79 79 76 71 67 62 82 82 79 74 70 65 84 84 81 76 72 66 3000 0.183 78 79 75 71 66 62 82 82 79 74 69 65 85 86 82 77 72 67 87 88 84 79 74 69 Inlet Prl. Min. Sound Power @ 1.5" A P3 Size cfm 41 Ps 2 3 4 5 6 7 6 400 0.200 57 67 58 53 45 39 8 700 0.160 64 74 66 59 52 47 10 1100 0.130 71 80 73 67 58 53 12 1600 0.140 76 85 79 68 63 58 14 2100 0.120 79 88 83 71 67 62 16 2800 0.200 83 92 88 74 70 66 Unit Size inlet Size cfm Min. A Ps Primary Air • Sound Power Octave Bands 0.5" A P5 1.0" 1 Ps 2.0 ".A Ps 3.0 "A P 2 3 4 5 1 6 7 2 1 3 4 5 1 6 7 2 3 4 5 6 7 2 3 1 4 1 5 6 7 TITUS® Fan Po ed Terminals > Performance Data 4 UO 1946 D 1996 Models: PMFV, AMFV, DMFV • Discharge Sound Power Levels • 100% Primary Air ARI Certification Rating Points > Min. A P is the lowest static pressure difference (damper wide open). > Discharge sound power is the noise emitted from the unit discharge into the downstream duct. > Sound power levels are in decibels. re 10' watts. • All sound data are based upon tests conducted in accordance with ARI 880.94. Note: Ratings in accordance with ARI Standard 880 -94 and certified to ARI. A Participating Corporation in the ARI 880 Certification Program RECE TUKWItA CITY OF MAR 2 0 1998 PERMIT CENTER S45 ' 2 300 0.25 63 57 58 50 43 39 52 54 52 51 42 33 350 0.25 64 58 59 51 45 41 54 55 53 52 43 35 400 0.25 65 59 60 52 47 42 55 56 54 53 44 37 450 0.25 66 60 61 53 48 44 56 57 55 54 45 38 500 0.25 67 60 62 54 50 45 57 58 56 54 46 40 520 0.25 67 61 63 55 50 46 58 59 57 54 47 40 3 475 0.25 66 62 58 50 45 41 60 63 58 54 52 44 500 0.25 66 62 58 51 46 42 61 63 59 55 53 45 525 0.25 67 63 59 51 46 43 62 64 60 56 53 46 550 0.25 67 63 59 52 47 44 63 64 60 56 54 47 600 0.25 67 64 60 53 48 46 64 65 62 57 56 48 650 0.25 68 64 61 54 50 48 65 66 63 58 57 50 4 600 i 0.25 66 64 61 53 50 45 60 55 57 51 47 41 700 0.25 67 64 61 54 52 48 61 56 58 53 49 43 800 0.25 67 64 62 55 54 50 62 57 59 55 51 45 900 0.25 68 64 62 56 55 52 63 58 60 56 52 47 1000 0.25 68 65 63 57 57 53 64 59 60 57 53 49 1150 0.25 69 65 64 58 59 55 65 60 61 58 55 51 5 800 0.25 66 61 60 54 51 46 61 56 57 53 48 41 900 0.25 67 62 61 55 53 48 63 58 60 55 51 44 1100 0.25 69 65 64 58 56 52 66 62 63 59 55 49 1300 0.25 71 67 66 60 59 56 69 65 66 62 59 53 1500 0.25 72 69 68 62 61 58 71 68 69 65 62 56 1800 0.25 74 71 70 64 64 62 74 71 72 68 66 60 6 1250 0.25 68 66 63 58 57 52 66 64 64 60 59 52 1350 0.25 69 67 64 59 58 54 68 65 65 61 60 53 1500 0.25 70 68 65 60 59 56 69 66 67 63 61 55 1650 0.25 71 69 66 61 61 58. 71 68 69 65 63 57 1800 0.25 72 70 67 62 62 59 72 69 70 66 64 59 2100 0.25 74 71 69 63 64 62 74 72 73 69 67 62' Unit Size Fan cfm Outlet APS Radiated Sound Power Discharge Sound Power Octave Bands Octave Bands 2 3 1415 617 2 314 516 E C- S46 TITUS® AR! Certification Rating Points Fan Powered Terminals > Performance Data 4u 1 9 6 0 1996 Models: PMFV, AMFV, DMFV • Sound Power Levels • Fan Only • Heating Cycle > Outlet AP is the difference in static pressure from the terminal discharge to the room. > Radiated sound power is the noise transmitted through the casing walls. Neo > Discharge sound power is the noise emitted from the unit discharge into the downstream OF ' > Sound power levels are in decibels, re 10 watts. > All sound data are based upon tests conducted in accordance with ARI 880.94. OCI Note: Ratings in accordance with ARI Standard 880.94 and certified to ARI. tAAR 2 t �gg� A Participating 130: ceS c in the ARI 880 Certification Program Radiated Sound Power Discharge Sound Power Unit Size Fan watts Fan cfm Fan Only Fan Only 2 3 4 5 6 7 2 3 4 5 6 7 2 175 400 70 64 66 58 53 49 61 62 60 57 52 49 3 375 680 73 69 68 61 57 57 73 73 70 65 65 62 4 450 950 72 68 67 62 62 59 68 64 65 62 59 55 5 900 1380 77 74 75 71 69 63 77 74 75 71 69 63 6 1000 1610 77 74 72 66 67 65 77 75 76 72 70 65 E C- S46 TITUS® AR! Certification Rating Points Fan Powered Terminals > Performance Data 4u 1 9 6 0 1996 Models: PMFV, AMFV, DMFV • Sound Power Levels • Fan Only • Heating Cycle > Outlet AP is the difference in static pressure from the terminal discharge to the room. > Radiated sound power is the noise transmitted through the casing walls. Neo > Discharge sound power is the noise emitted from the unit discharge into the downstream OF ' > Sound power levels are in decibels, re 10 watts. > All sound data are based upon tests conducted in accordance with ARI 880.94. OCI Note: Ratings in accordance with ARI Standard 880.94 and certified to ARI. tAAR 2 t �gg� A Participating 130: ceS c in the ARI 880 Certification Program ° - Campbell Company I N C O R P O P I W O 1515 - 4 Avenue South, Suite A • Seattle, WA 98134 -1512 206/622-3403 FAX 206/623-6978 Internet campbellecampbell- co.com Submittal No.: S 7574 March 6, 1998 LIEBERT PRECISION COOLING SYSTEM * ** SUBMITTALS * ** Project: BOEING EMPLOYEES CREDIT UNION Location: Tukwila, WA Contractor: Comfort Plus ONE (1) - LIEBERT "DELUXE SYSTEM /3" AIR COOLED PRECISION COOLING SYSTEM complete with the following: A.) Indoor unit: • Vertical upflow configuration (suitable for ducting) • Infrared humidifier with autoflush cycle - provides pure water vapor with quick response • Finned tubular electric reheat coils, 3 -stage • Non - locking through the door disconnect, accessible from front of system • 4 inch filters • Blower package with high efficiency motor, 200% drive • High voltage circuit protection for all components COV. • Advanced microprocessor control with graphics Dot Matrix Display Unit Alarms ..-- „\‘k Active Alarms Humidifier Problem fig Operating Status High / Low Temperature •Q\‘ Alarm History Log High / Low Humidity Component Run Time Log Loss of Air Flow Graphical Plots Change Air Filters Temperature Local Alarms (2) Humidity High Head Pressure Analog Inputs Low Suction Pressure Component Run History Short Cycle Alarm Floor Plan Layout for Loss of Power Water Detection Cable Smoke MB 005q REC CITY OF TUKWILA • MAR 2 0 1998 PERMIT CENTER c Campbell M Company I N L O 1515 - 4' Avenue South, Suite A • Seattle, WA 98134 -1512 206/622 -3403 FAX 206/623.6978 Internet campbell@campbell-co.com Submittal No.: S 7574 March 6, 1998 • Condensate pump, with integral check valve • Smoke detector, with auxiliary contacts for remote monitoring • Remote alarm interface (1 normally open contact to close on alarm) • Seismic Zone 4 Floorstand • Dual Refrigeration System: • Semi - hermetic compressors (two) • TX valves, filter /drier, site glasses, dehydrators, mufflers, high/low pressure switches • A -frame coil with intertwined refrigeration circuits • Stainless steel condensate pan • All side panels painted and finished - autophoretic powder paint • Shut down contacts • 5 -year extended compressor warranty B.) Outdoor condenser with fan speed control for low- ambient control to -20 °F Quantity Model Weight, # (shipping Indoor 1 UH 199A (15 Ton) 2375 Outdoor 2 CDF 205L 560 This equipment is fully described in the enclosed submittals. Y OF TUKWILA. MAR 2 0 1998 PERMIT 'CENTER A B C U CABINET SECTION Downflow Upflow (Rear Return) Upflow (Bottom Return) Cut Down Frame (FH Only) N Upflow (Front Return) Top Plenum "( mm) Hiah I IToc I IFront I IRear 1 (Grille I I1 " (25.4 mm) Flange Colors: Main Accent • NET CAPACITY DATA BTU /hr (kW) ❑ with Econ-O-Coil (FE/UE Units only) ( °C) DB — 6o O °F ( °C) WB Total /76 1 /(7 0 ___ZZ--•F 5V % RH Sensible /5'-5 90_0 •Econ•O•Coll Capacity Based on 45 °F (7.2 °C) E.W.T., GPM (—______1/s), psig (__ kPa) Total' Sensible' EVAPORATOR FAN SECTION Fan Motor Horsepower (kW) .7 Air Volume - CFM Ills) k4OO External Static Pressure • Inches of Water (Pa) ' _S— FILTER SECTI "Efficiency Based on ASHRAE Standard 52.76 Depth Size Quantity /Unit X 4" (102 mm) 20 % •• 24" x 24" (610 mm x 610 mm) .3 4" (102 mm) 30 %•• 20" x 25" (508 mm x 635 mm) 6" (153 mm) 65 %•• 18" x 24" (457 mm x 610 mm) 16" x 20" (406 mm x 508 mm) 2" ( 51 mm) 20 %• • No Filters Supplied Extra Sets HUMIDIFIER SECTION X Infrared with Autoflush Capacity - lbs/hr (kg /hr) /7,4r kW G •y J Steam Capacity • lbs/hr (kg/hr) Steam Supply - psig (kPa) Steam Generator Capacity - lbs/hr (kg /hr) / kW Ultrasonic (Downflow) Capacity - lbs/hr (kg/hr) kW No Humidifier Supplied REHEAT SECTION tlncludes Fan Motor )(Electric • 3 Stage Capacity • BTU /hr (kW)t 93000 Hot Water . Based on Capacity • BTU /hr (kW)t _ 180 °F (82.2 °C) E.W.T. Flow Rate - GPM (Ifs) Pressure Drop • psig (kPa) J Steam Capacity - BTU /hr (kW)t Steam Supplied - °F ( °C) 1 No Reheat Supplied AIR COOLED CONDENSER SECTION Air Cooled Condenser Part Number - Direct Drive CDFO2O$L, /9 Design Ambient - "F (•C) 95 ° Lee -Temp Control (115V) Lee -Temp Control (208/230V) 300 Watt Heater Pads /Fan Speed Control Condenser Disconnect Switch Heat Reclaim Module: No Condenser and No Condenser Controls (one /circuitL CONTROL SECTION I (Standard Microprocessor l I Advanced Microprocessor Da Advanced Microprocessorw / Graphics “Terminals Located on Wire Raceway. All Alarms Require N.O. Contacts. No. Local Alarms (1 only for Std.; 4 max. for Advanced & Graphics) Terminalstt; 4 Step System — — 50 51 55 24 + t i t t t A t i t t i t► i i r, i t CO t t t , t t t t I I 1.1 1 1 1 t 1 4 1 ❑ Main Fan Overload ❑ Compressor Overloads 24 Volt A.C. — OPTIONAL EQUIPMENT X Nonlocking Disconnect Switch Floorstand ❑ w/Turning Vanes X4 yr. Extended Comp. Warranty 7 , Locking Disconnect Switch " ( mm) High Liqui•Tector Panel Condensate Pump JHot Gas Bypass ❑ One Circuit ❑ Both Circuits Quantity Liqui•Tects ____JUnit Firestat )(Smoke Detector Crankcase Heaters JQuantity Encased Recorders (Temp. & Humid) (Order _Rergote Temp. /Humid. Sensors ft ( mm) Cable Ground Wires DI Bottle I DI Bottle Hose Kit tar - lsofor . LOA Liebert 1050 PO 6 Co"'' 4.ous O".o43229 U 4/ 0 9 4 G Quantity Project Name Model No. REMARKS ( DELUXE SYSTEM /3 S'. :CIFICATION SHEET Air Cooled Systems Liebert Invoice NQ Date 3 ELECTRICAL S U P P L Y REQUIREMENTS Liebert Room Unit gi& O Volt, Phase, O Hertz, Co Full Load Amps, 63 3 Cooled Condenser _ y�0O V olt, 3 Phase, _ 0 • Hertz Full load Amps �S C� Wire Sizing Amps Wire Sizing Amps CITY Tj jkyyl� MAR 2 0 1998 PERMIT CENTER LILsERT AIR COOLED M6JELS STANDARD FEATURES COMPRESSORS Semi- hermetic with a suction gas cooled motor, vibration isolators, thermal overloads, oil sight glass, manual reset high pressure switch, pump down low pressure switch, suction line strainer, reversible oil pumps, and operating at 1750 RPM 0 60 HZ and 1450 RPM CP 50 HZ. The lead/lag sequence of the compressors may be manually reprogrammed at the processor board. REFRIGERATION SYSTEM Dual refrigeration circuits, each including hot gas mufflers, liquid line filter dryers, refrigerant sight glass with moisture indicator; adjustable externally equalized expansion valves, and liquid line solenoid valves. COOLING COIL A -Frame design with Interwoven circuiting constructed of copper tubes and aluminum fins manufactured by • Liebert. A stainless steel condensate drain pan is provided. FANS Centrifugal type, double width, double inlet, dynamically balanced to a vibration tolerance of two mils in any plane with lifetime lubricated self - aligning ball bearings rated at a minimum life of 100,000 hours. The fan motor operates at 1750 RPM for 60 HZ and 1450 RPM for 50 HZ. The drive package is two belt, variable speed, sized for 200% of the fan motor horsepower. FILTERS Deep pleated with a minimum efficiency rating of 20% (based onASHRAE 52 -76) located within the cabinet and serviceable from either end of the unit (or top on downflow models). STANDARD CONTROL PROCESSOR (SM) The standard control system is microprocessor based with an internal LED numerical display to allow observation of specified setable functions. Normal operating modes of Heating, Cooling, Humidification, and Dehumidification are indicated on the LED unit mounted display panel. The control system also includes manual compressor sequencing and monitors unit operation and activates an alarm when any of the specified factory preset conditions are ex- ceeded. CABINET AND FRAME Custom powder painted steel panels with 1' (25.4mm), 1 1/2 lbs. (.68 kg) insulation. A hinged control access panel opens to a second front panel which is a protection enclosure for all high voltage components. Frame is constructed of 14 gauge heliarc welded tubular steel and painted using an autodeposition coating system. HUMIDIFIER High intensity Infrared quartz lamps over a stainless steel humidifier pan. An automatic water supply system continuously maintains water level and an automated flush system greatly reduces mineral precipitation. A flow control valve permits operation at water pressure between 5 and 150 PSIG (34.5 and 1034 kPa). REHEAT Electric low watt density reheat elements of rugged finned tubular construction provides three stages of nonionizing reheat with maximum sheath temperatures below 420 °F (215.5 °C). CITY RECEIVED MAR 2 0 1998 PERMIT CENTER LIEdERT AIR COOLED MCI)ELS OPTIONAL FEATURES (Refer to specification sheet for options supplied) STEAM GRID HUMIDIFICATION "Armstrong" steam separator type with an internal drying chamber and steam jacketed stainless steel distribution manifold. The complete system includes a prepiped solenoid control valve, inverted bucket steam trap and cleanable Y strainer. STEAM REHEAT System is factory piped with a two -way modulating control valve and cleanable Y- strainer. A F & T steam trap is factory supplied for field installation. Reheat coil is of copper tube and aluminum fin construction. HOT WATER REHEAT System is factory piped with a two -way modulating control valve and cleanable Y strainer. Reheat coil is of copper tube and aluminum fin construction. CONDENSATE PUMP Has capacity of 145 GPH (548 Vh) at 20 ft. head (58 kPa). Pump is complete with integral float switch, pump, motor assembly, and reservoir. UNiT DISCONNECT SWITCH Two types of switches are available. The "Non- Locking Type" consists of a non - automatic molded case switch operational from the outside of the unit.Access to the high voltage electric panel compartment can be obtained with the switch in either the "on" or "off" position. Tbe_ 1. ockingZype= isidenticalexeept- sceess-te-t e - compartmenteerrbeebteined only - with- the - switch -in -the= off"- position? FIRESTAT Is mounted in the electric panel compartment with the sensing element in the return air flow. Upon activation the Firestat will immediately shut down the entire unit. SMOKE DETECTOR Is mounted in the unit with the sensing element in the return air flow. Upon activation the smoke detector will immedi- / �' ately shut down the entire unit and activate the alarm system. FILTERS Three optional filters are available.A20% prefilter, and 30% or 65% main filter may be specified (efficiency based onASHRAE 52- 76). LIQUI -TECT SENSOR Is a solid state water sensor that has no moving parts and is hermetically sealed to keep out dust and dirt. When the sensor detects the presence of moisture the alarm system is activated. REMOTE TEMPERATURE AND HUMIDITY SENSORS Are provided in a vented case for mounting in the room to be conditioned. Includes 30 ft. (9m) of cable supplied for connecting sensors to unit. FLOORSTAND Is constructed of heliarc welded tubular steel and available in heights from 9" to 24" (229mm to 610mm) with vibration � isolation pads provided on the adjustable legs. An optional factory supplied turning vane is available for field installation if desired. PLENUM Constructed of steel panels with 1" (25.4mm), 1 1/2 lb. (.68kg) insulation custom painted in unit matching colors. Available in nominal heights of 20" (508mm), 24" (610mm) and 36" (914mm) in several standard configurations. ADVANCED MICROPROCESSOR CONTROL (AM) The advanced control system includes the following control, monitor and alarm fea- tures: BACKLIT 4x20 LCD, SELECTABLE CONTROL LOGIC (Proportional, PID, INTELLIGENT', PROGRAMMABLE ANALOG IN- PUTS, COMPONENT RUN HOUR DATA, TEMPERATURE ANTICIPATION, SELECTABLE HUMIDITY CONTROL, AUTOMATIC RE- HEAT SEQUENCING, SEQUENTIAL LOAD ACTIVATION, SEQUENTIAL AUTO RESTART, PROGRAMMED HUMIDIFIER WATER CYCLE, COMPRESSOR SHORT CYCLE CONTROL, SENSOR CALIBRATION, MANUAL COOLING OVERRIDE SWITCHES, PRO- GRAMMABLE COMMON ALARM, ALARM HISTORY LOG, PROGRAMMABLE COIL FLUSH CYCLE, UNIT AND CONTROL DIAG- NOSTICS, BATTERY BACKUP. ADVANCED MICROPROCESSOR CONTROL W/ GRAPHICS (AG) Includes all the features of the Advanced Microprocessor Control above, except the 4x20 LCD is replaced with a backlit 240x128 dot matrix graphics display. In addition, the AG includes a larger alarm y history file, graphical plots of temperature, humidity, and the analog Inputs, bar graph plots of component run history, and a graphical /„../.......47 floor plan layout for an optional water detection cable system. ECON-O-COIL (Available on Downflow (FH) units only) Is a custom designed 6 -row coil of copper tubes and aluminum fins installed in the return air portion of the unit. Full capacity of the coil is obtained at 45 °F (7.2 °C) entering fluid temperature.The coil will also provide partial cooling as long as the entering fluid temperature is 3 °F (1.7 °C) below the room temperature and is activated at that point by the solid state comparative circuit that compares the entering fluid temperature to the return air temperature. 4 STEP SYSTEM (Available on 8-30 ton units only) Includes cylinder unloaders on one head of each compressor. Four steps of DX cooling are obtained as follows: Step 1 - one compressor unloaded, one compressor off. Step 2 - both compressors unloaded. Step 3 - one compressor unloaded, one compressor on full. Step 4 - both compressors on full. HOT GAS BYPASS Factory piped hot gas solenoid valve and externally equalized regulating valve in one or both refrigerant circuits (Not available with 4 -Step option). STEAM GENERATING CANISTER HUMIDIFIER This system is housed in a steel enclosure and includes a replaceable canister with integral fill cup, fill and drain valves, and high water indicator. System automatically fills and drains as well as maintains the required water level based on conductivity. ULTRASONIC HUMIDIFIER (Available on Downflow (FH) units only) This system contains PIEZO electric ceramic transducers, supply and drain valves and all electronic level sensing and other safety devices. Operational and fault indications are displayed on the humidifier status panel. Humidifier requires DI water to operate. DI WATER BOTTLE This is required for ultrasonic humidifier. It contains a mixed bed resin for removing mineraibtj Wel9r supply. lqU,�n� O TUKWILA 'The Intelligent control approximates the actions that a human operator would take to maintain precise, stable control. T4►eroefrtrm I4i4 Artificial IntelligenceTechniques including "Fuzzy Logic" and "Expert Systems" methods. PERMIT CENTER TYPICAL aCNERAL ARRANGEMENT DIAGRAM AIR COOLED MODELS (Two refrigeration circuits required — Single circuit shown only for clarity) 1 11 It 11 II 11 Traps Every I I 25 FL (7.6m) Of Rise 11 1 1 II 11 1I II 11 11 11 11 11 u 11 1 11 11 11 11 11 11 11 1 It II 11 1 11 11 11 11 II 11 11 1 1 11 Liquid Return 11 .1 11 Shut.* Off Valve 11 1 11 1I 1 1 11 11 11 1 11 11 11 11 1 11 11 11 11 11 11 11 11 11 11 11 .• p1 Hot Gas • • Discharge • 11 ��• 1 8 1 • 1 ri Muffler * Filter Dryer Sight Glass Solenoid Valves II Hot Gas 11 By-Pass II (Optional) ii Muffler Service Valves Schrader Valve Compressor FIELD PIPING `Components are not supplied by Liebert but are recommended for proper circuit operation and maintenance Condenser Coil Expansion Valve (Optional) Cylinder Unloaders Fusible Plug Inverted Traps on discharge and return lines to extend above base of coil by a minimum of 7 112 "(19Omm) Evaporator Coil /• Hot Gas External • By -Pass Equalizers SINGLE REFRIGERATION CIRCUIT SHOWN FACTORY PIPING — :OPTIONAL PIPING Sensing Bulb ** Components supplied 110Ipb TUKWII q and must be field installed (FHIUH and FEJUE 2i goA and 380A models onitY.1111 p 1998 PERMIT CENTS,.; - AIR COOLED MODELS DIMENSIONAL DATA Inches (mm). • SHIPPED WEIGHT Ibs (kp) A B ' 0 2R2Sg3 . 13 E F G H J 50 HZ 60 HZ U11-75A U14-75A 74 (1880) 70 (1778) 30 (762) 72 (1829) 31 (787) 33 5/8 (854) 69 3/4 (1772) 20 1/4 (514) 1510 (685) 114-115A UH -114A 74 (1880) 70 (1778) 30 (762) 72 (1829) 31 (787) 33 5/8 (854) 69 3/4 (1772) 20 1/41 (514) 1660 (753) UN -130A UN -125A 74 (1880) 70 (1778) 30 (762) 72 (1829) 31 (787) 33 5/8 (854) 69 3/4 (1772) 20 1/1 (514) 1650 (748) 1114-199A >IC UH -191A 92 (2337) 88 (2235) 30 (762) 90 (2286) 31 (787) 33 5/8 (854) 87 3/4 (2229) 20 1/4 (514) 1880 (853) UH -215A' UH -245A 99 (2515) 95 (2413) 32 (813) 97 (2164) 33 (838) 35 5/8 (905) 94 3/4 (2407) 20 1/4 (514) 2100 (953) UH -2110A UH -290A 99 (2515) 95 (2413) 32 (813) 97 (2464) 33 (838) 35 5/8 (905) 94 3/4 (2407) 20 1/4 (511) 2210 (1016) UN -300A 104-310A 122 (3098) 118 (2997) 32 (813) 120 (3048) 33 (838) _35 5/8 (905) 113 1/2 (2883) 20 1/4 (51444,2ZEI, (1260) CABINET AND PROJECTION OF DISPLAY BEZEL 5/8' (16mm) 1' 2' (25,4mm) j (50.8mm) -+" 72' (1829mm) AIR GRILLE SUPPLIED ON UNITS WITH FRONT RETURN AIR ONLY SHADED AREAS INDICATE A RECOMMENDED CLEARANCE OF 34' (864mm) BE PROVIDED FOR COMPONENT ACCESS AND FILTER REMOVAL FOR RECOMMENDED MINIMUM CLEARANCE REFER TO THE INSTALLATION MANUAL. 1 118 Overall Olmonston ,(28.6mm) F D dse :OOR PLANNING DM DATA UPFLOW (UH) MODELS UNIT DIMENSIONAL DATA 5 1/2' (139.7mm) A OvoralU D lmonsl on B 0b_ 1' (25.4mm) AIR RETURN OPENING FLOOR CUTOUT DIMENSIONS MODELS WITH BOTTOM RETURN 2' '~ (50.8mm) 4' (101.6mm) B .4mm) FLANGE FOR DUCT OR ENUM CO NECTIO * A - S Pr 4ir ISVP4 P 4r , (282.6 DUCT CONNECTION DATA MODELS WITH REAR RETURN AIR RETURN OPENING yr r OF TUKW MAP 2 0 1998 UNIT PIPING OUTLET CONNECTION SIZES, inches AIR COOLED MODELS A OD CU B OD CU C NPT MALE D OD CU E NPT MALE F OD CU 50 HZ 60 HZ UN -75A UN -75A 5/8 1/2 1/2 5/8 1/2 : 5/8 UN -115A UN -114A 5/8 1/2 1/2 5/8 1/2 5/8 UN -130A UN -125A 5/8 1/2 1/2 5/8 1/2 5/8 UN-199/1 UN -199A 7/8 1/2 3/4 7/8 3/4 7/8 UN -245A UN -245* 11/8 5/8 3/4 7/8 3/4 7/8 1101-2110A U11-2•0* 11/8 5/8 NA NA NA NA UN-35011 1N1 -311* 11/8 5/8 NA NA NA NA h 4 5/8 • (117mm) � 1 • (25.4mm) REAR PANEL r - 7I8' (22.2mm) 10 3/4' 11fVw 3/4" NPT condensate drain. (273mm) -- Field pitch a min. of 1/8" (3.2mm) per ft. (305mm). A trap is required in drain. PTI 2 3/8' (80.3mm) UNIT LEFT END PANEL LS AIR COOLED MC.JELS UPFLOW (UH) MODELS UNIT PIPING OUTLET LOCATIONS Piping stubbed out inside unit end compartment for field connection through 2 3/8" x 10 3/4" (60.3 x 273 mm) opening as shown. Piping is recessed Inside the unit and not flush as indicated. Piping may also exit through bottom of end compartment by field cutting an opening In a suitable location (except bottom return air units). r " A t R :N IIi1IIIIIIIIiII �.. UATOR hI h 'II III 11111 1 I - _ � � I IIrill RET _ ��� .� ■�- ......._ e ATER R EH - " r w h ■ ■ . 4 4 W li i 11W UATO' II I� b,1,4"miliiiii, II� III • �1 II ® I�I -ai- T COIL IIIIIIIIIIIiIIII �_� �� ► HOT WA '._ . '� OPTION TOT ' • ter" AT A - Hot Gas Refrigerant Lines (Field install factory supplied muffler on 245A, 290A and 380A models). 8 - Liquid Refrigerant Lines. 1/4" OD CU Humidifier Water Supply Line. f L_ 1/2" NPT Male Steam Humidifier Supply Line. 1/2" NPT Male Steam Humidifier Return Line. C - Steam Reheat Supply Line. F - Hot Water Reheat Return Line. — - Steam Reheat Return Line (Field Install factory sup- plied steam trap with vacuum breaker). D - Hot Water Reheat Supply Line. PLENUM PIPING OUTLET LOCATIONS Plenum must be provided to house steam and hot water piping on UPFLOW (UH) units. Piping may exit through bot- tom, top or sides by field cutting an opening in a suitable location. HEAT (3-WA COIL • LVE) PLENUM LEFT END PANEL CI7 y R OF E TUKW I LA ! AR 2 0 1998 EFMfr CENTER Three phase electric service not by Liebert. Three phase connection. Electric service connection terminals when factory disconnect switch is supplied. Factory installed disconnect switch (optional). Smoke detector alarm connections Field supplied 24V. Class 2 wire to remote alarm circuits. Factory wired contacts from optional smoke detector are #91- comm., #92 -NO, and #93 -NC. Common alarm connection. Field supplied 24V. Class 2 wiring to common alarm from pigtails 75 + 76 which are factory connected to common alarm relay (R3). Electrical handy box factory installed with cover. Heat refection connection. Field supplied 24V. Class 1 wiring to interlock heat rejection from pigtails 70 + 71 which are factory connected to compressor side switches. Remote unit shutdown. Replace existing jumper between terminals 37 + 38 with normally closed switch having a minimum 50VA rating. Use field supplied 24V Class 1 wire. NOTE: ELECTRICAL FIELD CONNECTIONS Field supplied disconnect switch when factory installed unit disconnect switch is not provided. Factory installed unit disconnect switch (optional). Monitoring panel. Electric conduit knockouts on bottom of wire raceway. Knockout sizes 1 3/8" (34.9mm) or 1 3/4" (44.5mm) or 2 1/2" (63.5mm). Factory wired to components on electric panel. Electric service connection block. Three phase connection. Electric service connection terminals when factory disconnect switch is NOT supplied. Earth ground connection (60 HZ). Connection terminal for field supplied earth grounding wire. supp lies#- ea+#h- pounding- wire-- Three phase electric service not by Liebert. Special alarm connections. Field supplied 24V. Class 1 wire for special alarms. Connections made by adding normally open contact between terminals (24 + 50), for Standard Microprocessor. The Advanced Microprocessor has four alarms at terminal (24 + 50), (24 + 51), (24 + 55), and (24 + 56). Analog inputs. Optional terminals 41 to 48 provide connections for shielded, twisted pair cable to as many as four customer supplied analog sensors (AM and AG only). She ■mrN.dng arwnchun. Terminals 77 ( —) and 78 ( +) are for connection of a 2 wire, twisted pair, communication cable (available from Liebert or others) to optional Sitescan and are factory connected to the interface board on the unit. CITy pF E T UI( ►V I � Refer to specification sheet for full load amp. and win size amp. ratings. MAR 2 o 1 99 8 PERMi1- CENTER GENERAL DISPLAY A 240 x 128 backlit dot matrix graphic LCD displays all monitoring, control, alarm, diagnostic and graphical information. KEYPAD 5 membrane keys for easy movement through the menu -driven control. STANDARD ALARMS TEMPERATURE The high and low temperature thresholds are programmable between 35 °F and 90 °F (1.6 °C and 32.2 °C). The alarm indicates excessive high or low return air temperature. HUMIDITY The high and low humidity thresholds are programmable between 15% and 85% R.H. The alarm indicates excessive high or low return air humidity. HUMIDIFIER PROBLEM Indicates excessive high or low water levels in the humidifier pan or full canister. HIGH HEAD Indicates a head pressure above a factory preset point. Unit is equipped with a factory preset compressor safety cutout switch. (Provided on DX units only.) CHANGE FILTERS Indicates the pressure drop across the filters has exceeded the customer -set level. LOSS OF AIR Indicates a loss of air flow in the unit based on mechanical sensing switches. LOW SUCTION PRESSURE Indicates a suction pressure below the preset cutout point. (on DX units) SHORT CYCLE ALARM Indicates the compressor has turned off -on-off at least 10 times in a one hour period. LOSS OF POWER Indicates that a power interruption has occurred. OPTIONAL ALARMS The following alarms are available when th Main Fan Overload Compressor Overload 1 & 2 (4) Local Alarms from below Standby Glycol Pump On Water Under Floor Smoke Detected Loss of Water Flow Stand -by Unit On MONflCRING PANEL AND UNtc ALARMS ADVANCED MICROPROCESSOR CONTROL W /GRAPHICS (AG) e appropriate options are included with the unit. Special Message 1 Special Message 2 Special Message 3 Special Message 4 FEATURES OF THE MONITOR MONITOR Room conditions, user analog sensors, run hours, alarm history, unit operating status. GRAPH Temperature, humidity, analog inputs, component run history, water detection floor plan. SET Password protected programming of various time delays and 'Unit configurations. SETPOINT Password protected programming of operational setpoints/alarms. • CITY OF TUKW 1 448 2 0 1998 PERMIT CENTER LIEBERT AIR COOED FAN SPEED CONS ROL CONDENSERS STANDARD FEATURES COIL Liebert manufactured coil is constructed of copper tubes in a staggered tube pattern. Tubes are expanded into continu- ous, rippled or enhanced aluminum type fins. The fins have full depth fin collars completely covering the copper tubes which are connected to heavy wall type L headers. Inlet coil connector tubes pass through relieved holes in the tube sheet for maximum resistance to piping strain and vibration. Coils are factory leak tested at a minimum of 300 PSIG, dehydrated, then filled with a nitrogen and refrigerant holding charge and sealed. FAN(S) Blades are constructed of zinc plated steel or aluminum with a maximum diameter of 30 inches and secured to the fan shaft by a heavy duty hub with set screw. Fan guards are heavy gauge, close meshed, steel wire with corrosion resistant finish. Fans are factory balanced and tested before shipment. FAN MOTOR(S) Are provided with rain slingers, permanently lubricated bearings, and individual built -In overload protection. Motors are rigidly mounted on die- formed galvanized steel supports. HEAD PRESSURE CONTROL A Liebert fan speed control system is furnished consisting of a variable speed fan motor operat- ing from 80 to 1075 RPM in 60 HZ operation and 180 to 900 RPM in 50 HZ operation. The fan motor is a specially designed single phase motor with permanently lubricated ball bearings and internal overload protection. The control system is complete with transducers, thermostats, and electrical control circuit factory wired in the control panel. Fan speed con- trol is always furnished on the fan adjacent to the connection end of the condenser which runs continuously with the compressors. Other condenser fans are controlled by ambient thermostats and are either "on" or "off ". This system allows for operation at ambient conditions as low as — 20 °F (— 28.9 °C). HOUSING The condenser housing is constructed of bright aluminum sheet and divided into individual fan sections by full width baffles. Structural support members, including coil support frame, motor, and drive support, are galvanized steel for strength and corrosion resistance. Aluminum legs are provided with rigging holes for hoisting the unit into position. 0 U T DI NA NNE EAT WI H loc ing d conn ct fa ory stall and Ired n en lo s co de er ntro e ti RE CITY RECEIVED TUKWILA MAR 2 0 1998 PERMIT CENTER UEBERT MODEL NO. Note 1 NO. A 0 C D TOTAL HEAT REJECTION 60 HZ Note 3 CFM (Us) 60 HZ TOTAL HEAT REJECTION 50 HZ Note 3 CFM (Vs) 50 HZ NET WEIGHT FANS IN. MM. IN. MM. IN. MM. IN. MM. BTU/W'F KW/•C Note 2 BTU/HPF WPC Note 2 LBS. KG. CSF/CDF-065 1 511/2 1308 44 1118 42 1067 - - 1464 .772 6866(3240) 1349 .712 5722(2700) 295 134 CSF /CDF -083L 1 511/2 1308 44 1118 42 1067 - - 1655 .873 6000 2831 1526 .805 5000 2359 295 134 CSFICDF-086 1 5112 1308 44 1118 42 1067 - - 1921 1.013 6633 3130 1751 .924 5527 2608 315 143 CSF /CDF-097 1 511/2 1308 44 1118 42 1067 - - 2228 1.176 63222983 1995 1.053 335 152 CSF/CDF-104L 1 511/2 1308 44 1118 42 1067 - - 1945 1.026 5400 2548 1733 .914 4500 v 1 315 143 CSF /CDF -107C 1 511/2 1308 44 1118 42 1067 - - 1938 1.022 6322 2984 1750 .929 lirjr.1 • 420 191 CSF /CDF-130 2 9112 2324 84 2134 82 2083 - - 2928 1.545 13732 6480 2696 1.423 425 193 CSF/CDF-165L 911/2 2324 84 2134 62 2083 - - 3310 1.746 12000 5661 3051 1.610 10000 4719 425 193 CSF/CDF-175 911/2 2324 84 2134 82 2083 - - 3842 2.027 13266 6260 3502 1.847 11065 521 495 225 CSF/CDF-205L 2 911/2 2324 84 2134 82 2083 - - 3976 2.098 10443(4928) 3509 1.851 6700(4107) 495 225 CSF/CDF-216C 2 911/2 2324 84 2134 82 2083 - - 4324 2.281 12176 574 3836 2.023 10132 4782 655 297 CSF/CDF-217C 2 9112 2324 84 2134 82 2083 - - 4721 2.491 EMI 4234 2.218 10537 4972 515 234 CSF /CDF•251L 3 311/2 3340 124 3150 122 3099 - - 4966 2.619 18000(8494) 4577 2.415 15000(707J 500 227 CSF/CDF-2.58 3 311/2 3340 124 3150 122 3099 - - 5763 3.040 19899 9390 5252 2.771 16582 .% 670 305 CSFICDF•291 3 311/2 3340 124 3150 122 3099 - - 6685 3.527 18 8950 5986 3.158 15805 458 741 337 CSFIC0F308L 3 311/2 3340 124 3150 122 3099 - - 5664 2.955 ITMEI 5264 2.777 13054 6160 670 305 CSF/CDF-330L 4 7112 4356 164 4166 82 2083 80 2032 6619 3.492 24000(11326) 6103 3220 20000(9438) 780 355 CSF/CDF-349C 3 311/2 3340 124 3150 122 3099 - - 6984 3.684 17397(8211) 8174 3258 14532(6859) 916 415 CSF/CDF-4151 4 711/2 4356 164 4166 82 2083 80 2032 7779 4.104 21600(10193) 6932 3.657 18000 (8499 815 370 CSF/CDF-480C 4 711/2 4356 164 4166 82 2083 80 2032 8915 4.703 25288(11933) 7981 4211 466 CSF/CDF510C 4 711/2 4356 164 4166 82 2083 80 2032 10086 5.321 21687(10234) 8763 . 4.623 CI t 4 s 1025 8CE(8 . 3 4}418„ 540 EYE BOLTS FOR LIFTING CONDENSER PROVIDED ON FOUR FAN MODELS ONLY CABINLi & ANCHOR DIMENSIONAL DATA FAN SPEED CONTROL CONDENSERS A - 70" (1778mm) OPTIONAL DISCONNECT SWITCH HANDLE 1 3/4' 1• I (44.5mm) (25.4mm) 1 3/4• (44.5mm) TYPICAL FOOTPRINT 43 3/16' 18' (457mm) C 112 (12.7mm) DIAMETER ANCHOR BOLTS (TYP.) 43 9116' (1107mm) B i I .4 UNIT ANCHOR PLAN T HEIGHT TO TOP OF 37 718• FAN GUARD (962mm) 431/8' (1095mm) A CLEARANCE OF 36 IN. (914.4mm) IS RECOMMENDED ON ALL SIDES FOR PROPEL OPERATION AND COMPONENT ACCESS. 4 LEGS FURNISHED FOR 1, 2 3 FAN MODELS 6 LEGS FURNISHED FOR 4 FAN MODELS MAR 2 0 1998 1. CSF model prefix is for single refrigeration circuit. CDF model prefix Is for dual refrigeration circuits. 2. All condenser fan motors are 3/4 H.P. 3. Total Heat Rejection given above is per circuit for CDF models. For CSF models double the capacity shown. The Total Heat Rejectio4 ei ree dif• ferential between saturated condensing temperature and entering ambient air temperature. To calculate Total Heat Rejection per condenser, n (ti f l ble value by temperature differential. RECOMMENDED REFRIGERANT LINE SIZES CU. OD. CONDENSER PIPING CONNECTION SIZES CU. OD. UNIT MODEL NUMBER TOTAL EQUIV. LENGTH FT. (m) HOT GAS LINE IN. (mm) LIQUID LINE IN. (mm) MODEL 50 (152) 5/8 (15.9 1/2 (12.7) NUMBER BF/BU42A 100 (30.5) 7/8 (222) 1/2 (12.7) CSF -065 7/8 (22.2) BFBU40A 150 (45.7) 7/8 (222) 5/8 (15.9) 1/2 (12.7) 1/2 (12.7) 50 (152) 718 (222) 1/2 (12.7) 5/8 (15.9) BFBU67A 100 (30.5) 7/8 (222) 1/2 (12.7) EFBU65A 150 (45.7) 718 (222) 5/8 (15.9) CDF -086 7/8 (22.2) 50 (152) 5/8 (15.9) 1/2 (12.7) CSF- 0971107C 1 1/8 (28.6) FWUF+ -75A 100 (30.5) 718 (222) 1/2 (12.7) 7/8 (22.2) 1/2 (12.7) 150 (45.7) 7/8 (222) 5/8 (15.9) 5/8 (15.9) 50 (152) 7/8 (222) 1/2 (12.7) FWUF1.114A/115A 100 (30.5) 7/8 (22.2) 5/8 (15.9) COF -130 FIWH•125A/130A 150 (45.7) 7/8 (222) 6/8 (15.9) CSF -165L 1 1/8 (28.6) 7/8 (22.2) 50 (152) 7/8 (222) 518 (15.9) 7/8 (22.2) 5/8 (15.9) FH/UH -199A 100 (30.5) 1 1/8 (28.8) 7/8 (22.2) 7/8 (22.2) I 150 (45.7) 1 1/8 (28.6) 7/8 (22.2) r CSF /COF -205L 50 (152) 1 1/8 (28.6) 7/8 (22.2) CSF /CDF- 217C1216C FWUH -245A 100 (30.5) 1 1/8 (28.6) 7/8 (22.2) CSF /CDF -251L 1 1/8 (28.6) FWUH -290A 150 (45.7) 1 1/8 (28.6) 7/8 (222) 1 1/8 (28.6) 7/8 (22.2) 50 (152) 3/4 (19.1) 1/2 (12.7) 1 1/8 (28.6) FHNH- 114AW11SAU 100 (30.5) 3/4.(19.1) 5/8 (15.9) CDF -308L 150 (45.7) 7/8 (22.2) 5/8 (15.9) CSF -330L 1 5/8 (41.3) 50 (152) 3/4 (19.1) 1/2 (12.7) COF -330L 1 3/8 (34.9) FWUH•12SAW130AU 100 (30.5) 7/8 (222) 5/8 (15.9) 1 3/8 (34.9) 1 1/8 (28.6) 1 150 (45.7) 7/8 (22.2) 5/8 (15.9) 1 1/8 (28.6) 1 50 (152) 7/8 (222) 518 (15.9) 1 FWU11•199AU 100 (30.5) 7/8 (22.2) • 7 / 8 ( CDF180C 1 5/8 (41.3) 150 (45.7) 1 118 (2B:6) 718 (22.2) CSF -510C 2 1/8 (54.0) 1 3/8 (34.9) 50 (152) 718 (222) 7/8 (222) 1 5/8 (41.3) 1 1/8 (28.6) I FHN14245AU 100 (30.5) 1 1/8 (26.6) 7/8 (22.2) 150 (45.7) 1'1/8 (28.6) 7/8 (222) 50 (152) 1 1/8 (28.6) 7/8 (222) FH/UH290AU 100 (30.5) 1 1/8 (28.6) 7/8 (22.2) 150 (45.7) 1 1/8 (28.6) 7/8 (22.2) 50 (152) 1 318 (345) 716 (22.2) FFWI$360A 100 (30.5) 1 818 (34.9) .7/8 (222) ■ 150 (45.7) 1 3/8 (345) 1 1/8 (28.6) 50 (152) 7/8 (22.2) 1/2 (12.7) UP126A/120A 100 (30.5) 7/8 (22.2) 5/8 (159) 150 (45.7) 7/8 (22.2) 5/8 (15.9) 50 (152) 7/8 (222) 5/8 (15.9) UP187A/180A 100 (30.5) 1 1/8 (28.6) 718 (222) 150 (45.7) 1 1/8 (28.6) 7/8 (22.2) 50 (152) 1 1/8 (28.6 7/8 (22.2) UP239W38A 100 (30.5) 1 1/8 (28.6) 7/8 (222) 150 (45.7) 1 118 (28.6) 7/8 (22.2) 50 (152) 1 We (28.6 F EC UP375Af374A 100 (30.5) 13/8 (34.9 OF ..:v /( '' 4 150 (45.7) 1 318 (349 1 1!8 r • R �. UP476A/474A 10 1331818 ,•( 8 150 (45.7) 1 318 (34.9) 1 UB r. Tt ENTERING HOT GAS LINE (TYP.) PIPING: FAN SPEED CONTROL CONDENSERS RETURNING LIQUID LINE (TYP.) INVERTED TRAPS ARE TO BE FIELD SUPPLIED AND INSTALLED (TYP.) WHEN INSTALLING TRAPS, CLEARANCE MUST BE PROVIDED FOR SWING OF END ACCESS DOOR. TRAPS TO EXTEND ABOVE BASE OF COIL BY A MINIMUM OF 7 1/2' (190mm). FOR RUNS LONGER THAN 150 FT. (45.7M) EQUIV. LENGTH CO FSUCF1MIaTOIIY FOR PROPER LINE SIZING. CONDENSER PIPING CONNECTION SIZES CU. OD. CONDENSER ENTERING RETURNING MODEL HOT GAS LINE LIQUID LINE NUMBER IN. (mm) IN. (mm) CSF -065 7/8 (22.2) 1/2 (12.7) CDF -065 1/2 (12.7) 1/2 (12.7) CSF -083L 7/8 (22.2) 5/8 (15.9) CDF -083L 1/2 (12.7) 1/2 (12.7) CSF -086 7/8 (22.2) 5/8 (15.9) CDF -086 7/8 (22.2) 1/2 (12.7) CSF- 0971107C 1 1/8 (28.6) 5/8 (15.9) CDF /0971107C 7/8 (22.2) 1/2 (12.7) CSF -104L 1 1/8 (28.6) 5/8 (15.9) COF -104L 7/8 (22.2) 1/2 (12.7) CSF -130 I 1/8 (26.6) 7/8 (22,2) COF -130 - 7/8 (22.2) 5/8 (15.9) . CSF -165L 1 1/8 (28.6) 7/8 (22.2) CDF -165L 7/8 (22.2) 5/8 (15.9) CSF -175 1 1/8 (28.6) 7/8 (22.2) COF -175 7/8 (22.2) 5/8 (15.9) r CSF /COF -205L 1 1/8 (28.6) 7/8 (22,2) 4 CSF /CDF- 217C1216C 1 1/8 (28.6) 7/8 (22.2) CSF /CDF -251L 1 1/8 (28.6) 7/8 (22.2) CSF /CDF•258 1 1/8 (28.6) 7/8 (22.2) CSF /CDF•291 1 3/8 (34.9) 1 1/8 (28.6) CSF -308L 1 5/8 (41.3) 1 1/8 (28.6) CDF -308L 1 3/8 (34.9) 1 1/8 (28.6) CSF -330L 1 5/8 (41.3) 1 1/8 (28.6) COF -330L 1 3/8 (34.9) 1 1/8 (28.6) CSF /C0E- 3601349C 1 3/8 (34.9) 1 1/8 (28.6) CSF -415L 2 1/8 (54.0) 1 1/8 (28.6) CDF -415L 1 3/8 (34.9) 1 1/6 (28.6) CSF -480C 2 1/8 (54.0) 1 3/8 (34.9 CDF180C 1 5/8 (41.3) 1 1/8 (28.6) CSF -510C 2 1/8 (54.0) 1 3/8 (34.9) CDF510C 1 5/8 (41.3) 1 1/8 (28.6) ENTERING HOT GAS LINE (TYP.) PIPING: FAN SPEED CONTROL CONDENSERS RETURNING LIQUID LINE (TYP.) INVERTED TRAPS ARE TO BE FIELD SUPPLIED AND INSTALLED (TYP.) WHEN INSTALLING TRAPS, CLEARANCE MUST BE PROVIDED FOR SWING OF END ACCESS DOOR. TRAPS TO EXTEND ABOVE BASE OF COIL BY A MINIMUM OF 7 1/2' (190mm). FOR RUNS LONGER THAN 150 FT. (45.7M) EQUIV. LENGTH CO FSUCF1MIaTOIIY FOR PROPER LINE SIZING. Electric service connection and fuse block. Factory wired to 24V Class 2 control circuit. Control interlock Field supplied Class 2 wiring to interlock condenser 24V controls to Liebert room unit. 7/8 in. (22.2mm) diameter hole provided in bottom of electric box. Factory wired to components on electric panel. -vollage— eartb- grernMing -wtre- Earth ground connection (60 HZ). Connection terminal for field supplied earth grounding wire when factory disconnect is NOT supplied. �apptied: --- ELEC i RICAL FIELD CONNLCTIONS FAN SPEED CONTROL CONDENSERS Electric service connection terminals when factory disconnect is NOT supplied. disconnect -le - stpplie6. switch- (eptionst} Electric service entrance. A 7/8 in. (22.2mm) diameter hole in a 1 1/8 in (28.6mm) knockout provided in bottom of electric box. Electric service, not by Liebert. Single phase for condenser models CSF, COF, •065, •086, -097, and -108. Three phase for all other condenser models. CITYR WILA • NOTE: Refer to specification sheet for full load amp. and wire size amp. ratings. s MAR Z Q , 1998 PERMIT CENTER I Trane Air Conditioning Economics By: Comfort Plus ** ** CORPORATE SQUARE BLDG 7 TUKWILA, WA LOAD DESIGN - 1 Air Density: Air Specific Heat: Density- Specific Heat Prod: Latent Heat Factor: Enthalpy Factor: ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** ** TRACE 600 ANALYSIS ** by Comfort Plus ** ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Weather File Code: SEATTLE Location: SEATTLE, WA Latitude: 47.0 (deg) Longitude: 122.0 (deg) Time Zone: 8 Elevation: 386 (ft) Barometric Pressure: 29.5 (in. Hg) Summer Clearness Number: 0.95 Winter Clearness Number: 0.95 Summer Design Dry Bulb: 82 (F) Summer Design Wet Bulb: 66 (F) Winter Design Dry Bulb: 24 (F) Summer Ground Relectance: 0.20 Winter Ground Relectance: 0.20 0.0749 (Lbm /cuft) 0.2444 (Btu /lbm /F) 1.0988 (Btu- min. /hr /cuft /F) 4,836.9 (Btu- min. /hr /cuft) 4.4953 (Lb- min. /hr /cuft) Design Simulation Period: June To November System Simulation Period: January To December Cooling Load Methodology: TETD /Time Averaging Time /Date Program was Run: 22:56 :59 2/26/98 Dataset Name: CORP7 .EZT ** N191 -0059 V 600 PAGE 1 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus AIRFLOW - ALTERNATIVE 1 Main Auxil. Room Outside Cooling Heating Return Exhaust Supply Exhaust System System Airflow Airflow Airflow Airflow Airflow Airflow Airflow Number Type (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) 1 VTCV 3,886 35,005 35,005 35,005 3,886 0 0 Totals 3,886 35,005 35,005 35,005 3,886 0 0 CAPACITY - ALTERNATIVE 1 Main Sys. Aux. Sys. Opt. Vent System System Capacity Capacity Capacity Number Type (Tons) (Tons) (Tons) 1 VTCV Totals ENGINEERING CHECKS - ALTERNATIVE 1 Percent System Main/ System Outside Number Auxiliary Type Air 1 Main VTCV Cooling SYSTEM SUMMARY (Design Airflow Quantities) Cooling Totals (Tons) 66.9 0.0 0.0 66.9 66.9 0.0 0.0 66.9 Cfm/ Sq Ft SYSTEM SUMMARY (Design Capacity Quantities) Main Sys. Capacity (Btuh) - 537,605 - 537,605 The building peaked at hour 15 month ENGINEERING CHECKS Cooling Cfm/ Sq Ft Ton /Ton Aux. Sys. Capacity (Btuh) Btuh/ Sq Ft Preheat Capacity (Btuh) 0 0 0 0 Heating 8 with a capacity of 56.3 tons Reheat Humidif. Opt. Vent Capacity Capacity Capacity (Btuh) (Btuh) (Btuh) 0 0 Heating - - -- Cfm/ Btuh/ Floor Area Sq Ft Sq Ft Sq Ft 11.10 1.80 523.0 290.3 41.33 1.80 -27.67 19,432 V 600 PAGE 2 Heating Totals (Btuh) 0 0 - 537,605 0 0 - 537,605 RECEIVED TUKWILA ma 2 0 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus SYSTEM CHECKSUMS System 1 Peak * * * * * * * * * * * * * * * * * * * * * * * ** COOLING COIL PEAK * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CLG SPACE PEAK * * * * * * * * * * ** HEATING COIL PEAK * * * * * * ** Peaked at Time = => Mo /Hr: 8/15 * Mo /Hr: 8/16 * Mo /Hr: 13/ 1 Outside Air =_> OADB /WB /HR: 78/ 64/ 70.0 * OADB: 78 * OADB: 24 * Envelope Loads Skylite Solr Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Outside Air Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup OV /UNDR Sizing 0 Exhaust Heat Terminal Bypass Space Sens. +Lat. (Btuh) 0 0 0 304,080 -1,985 1,301 0 0 0 303,395 99,482 99,103 270,224 468,809 794 0 Grand Total = => 772,998 (Tons) (Hbh) (Mbh) Hain Clg 66.9 803.2 736.0 Aux Clg 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 Totals 66.9 803.2 Hain Htg Aux Htg Preheat Reheat Humidif Opt Vent Total Ret. Air Ret. Air Sensible Latent (Btuh) (Btuh) 0 0 5,311 0 0 449 5,760 0 0 0 0 0 -794 0 0 0 0 -550 0 0 0 4,416 0 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airfl (cfm) 35,005 0 0 HEATING COIL SELECTION Capacity Coil Airfl Ent Lvg (Mbh) (cfm) Deg F Deg F -537.6 35,005 62.8 76.8 Infil 0.0 0 0.0 0.0 Supply -0.0 35,005 62.8 56.0 Minds 0.0 0 0.0 0.0 Return 0.0 0 0.0 0.0 Exhaust 0.0 0 0.0 0.0 Rs Exh -537.6 Auxil VTCV * Net Percnt * Space Percnt * Space Peak Coil Peak Percnt Total Of Tot * Sensible Of Tot * Space Sens Tot Sens Of Tot (Btuh) ( %) * (Btuh) ( %) * (Btuh) (Btuh) ( %) 0 0.00 * 0 0.00 * 0 0 0.00 0 0.00 * 0 0.00 * 0 0 0.00 5,311 0.66 * 0 0.00 * 0 -12,356 2.30 304,080 37.86 * 317,208 43.40 * 0 0 0.00 -1,985 -0.25 * -7,748 -1.06 * - 71,252 - 71,252 13.25 1,750 0.22 * 946 0.13 * - 10,571 - 14,696 2.73 0 0.00 * 0 0.00 * 0 0 0.00 0 0.00 * 0 0.00 * 0 0 0.00 0 -0.00 * 0 -0.00 * -1 -1 0.00 309,155 38.49 * 310,406 42.47 * - 81,823 - 98,305 18.29 * * 99,482 12.39 * 99,482 13.61 * 0 0 0.00 99,103 12.34 * 49,552 6.78 * 0 0 0.00 270,224 33.64 * 270,224 36.97 * 0 0 0.00 468,809 58.37 * 419,258 57.37 * 0 0 0.00 0 0.00 * 1,167 0.16 * -2,274 0 0.00 25,791 3.21 * 0 0.00 * 0 - 187,900 34.95 0 0.00 * 0.00 * 0 0.00 0 0.00 * 0.00 * 0 0.00 0 0.00 * 0.00 * 0 0.00 0 0.00 * 0 0.00 * - 252,976 - 252,976 47.06 -550 -0.07 * 0.00 * 1,577 -0.29 0 0.00 * 0.00 * 0 0.00 * * 803,205 100.00 * 730,830 100.00 * - 337,074 - 537,604 100.00 Entering DB /WB /HR Deg F Deg F Grains 75.3 61.4 60.1 0.0 0.0 0.0 0.0 0.0 0.0 AIRFLOWS (cfm) Type Cooling Heating Vent 3,886 3,886 0 0 35,005 35,005 0 0 35,005 35,005 3,886 3,886 0 0 0 0 - VARIABLE TEMP CONSTANT VOL Leaving DB /WB /HR Deg F Deg F Grains 56.0 53.4 57.6 0.0 0.0 0.0 0.0 0.0 0.0 -- ENGINEERING CHECKS- - Clg % OA 11.1 Clg Cfm /Sgft 1.80 Clg Cfm /Ton 522.99 Clg Sgft /Ton 290.32 Clg Btuh /Sgft 41.33 No. People 194 Htg % OA 11.1 Htg Cfm /SgFt 1.80 Htg Btuh /SqFt -27.67 V 600 PAGE 3 AREAS Gross Total Glass (sf) ( %) Floor 19,432 Part 0 ExFlr 0 Roof 9,440 Wall 9,456 0 0 2,760 29 -- TEMPERATURES (F) - -- Type Clg Htg SADB 56.0 76.8 Plenum 75.1 67.6 Return 75.1 67.6 Ret /OA 75.3 62.8 Runarnd 75.0 68.0 Fn HtrTD 0.0 0.0 Fn B1dTD 0.0 0.0 Fn Frict 0.0 0.0 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM COOLING - ALTERNATIVE 1 V 600 PAGE 4 PEAK COOLING LOADS (Main System) Space Coil Peak OA Rm Supp. Space Space Space Peak OA RI Supp. Coil Coil Coil Time Cond. Dry Dry Air Sens. Lat. Time Cond. Dry Dry Air Sens. Lat. Room Mo /Hr DB /WB Blb Bulb Flow Load Load Mo /Hr DB /WB Blb Bulb Flow Load Load Number Description (F) (F) (F) (Cfm) (Btuh) (Btuh) (F) (F) (F) (Cfm) (Btuh) (Btuh) 1 7/ 9 67 57 75 56.0 395 8,257 979 7/14 79 65 75 58.5 395 7,521 1,583 2 7/17 78 61 75 56.0 3,724 77,749 3,917 7/17 78 61 75 56.0 3,724 78,773 3,360 3 10/12 63 54 75 56.0 2,204 46,011 1,958 9/13 74 61 75 56.8 2,204 43,820 2,423 4 7/ 9 67 57 75 56.0 1,193 24,914 1,224 8/ 9 67 59 75 56.1 1,193 23,846 1,514 5 data 7/ 9 67 57 75 56.0 9,243 192,976 2,448 8/ 9 67 59 75 56.0 9,243 190,992 3,029 6 mdf 7/ 9 67 57 75 56.0 2,649 55,302 673 8/ 9 67 59 75 56.0 2,649 54,740 833 7 7/15 80 64 75 56.0 2,442 50,988 11,669 7/14 79 65 75 56.0 2,442 55,009 18,863 8 lobby -1 6/19 69 55 75 56.0 615 12,848 2,611 7/14 79 65 75 56.1 615 13,755 4,221 Zone 1 Total /Ave. 78 63 75 56.0 22,466 469,045 25,480 78 64 75 56.1 22,466 468,456 35,825 Zone 1 Block 8/16 78 63 75 58.9 22,466 396,743 25,480 8/15 78 64 75 59.0 22,466 401,117 41,188 9 7/ 9 67 57 75 56.0 395 8,257 979 7/14 79 65 75 58.5 395 7,764 1,474 10 7/17 78 61 75 56.0 3,724 77,749 3,917 7/17 78 61 75 56.0 3,724 80,546 2,924 11 10/12 63 54 75 56.0 2,204 46,011 1,958 9/13 74 61 75 56.8 2,204 43,822 2,205 12 7/ 9 67 57 75 56.0 3,158 65,932 2,938 8/ 9 67 59 75 56.1 3,158 63,081 3,308 13 7/19 74 58 75 56.0 2,442 50,988 11,669 7/14 79 65 75 56.0 2,442 57,901 17,566 14 lobby -2 6/19 69 55 75 56.0 615 12,848 2,611 7/14 79 65 75 56.1 615 14,403 3,931 Zone 2 Total /Ave. 78 63 75 56.0 12,539 261,785 24,072 78 64 75 56.3 12,539 267,516 31,408 Zone 2 Block 8/16 78 63 75 61.4 12,539 187,096 24,072 8/15 78 64 75 61.6 12,539 197,607 36,237 System 1 Total /Ave. 78 63 75 56.0 35,005 730,830 49,552 78 64 75 56.2 35,005 735,972 67,233 System 1 Block 8/16 78 63 75 59.8 35,005 583,839 49,552 8/15 78 64 75 59.9 35,005 598,724 77,426 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus MAIN SYSTEM HEATING - ALTERNATIVE 1 V 600 PAGE 5 PEAK HEATING LOADS (Main System) Space Coil Peak OA Rm Supp. Space Space Peak OA Rs Supp. Coil Coil Floor Time Cond. Dry Dry Air Sens. Time Cond. Dry Dry Air Sens. Room Area Mo /Hr DB /WB Blb Bulb Flow Load Mo /Hr DB /WB Blb Bulb Flow Load Number Description (Sq Ft) (F) (F) (F) (Cfm) (Btuh) (F) (F) (F) (Cfm) (Btuh) 1 384 13/ 1 24 21 68 76.8 395 -3,808 13/ 1 24 21 68 76.8 395 -7,651 2 1,536 13/ 1 24 21 68 76.8 3,724 - 35,859 13/ 1 24 21 68 76.8 3,724 - 52,099 3 768 13/ 1 24 21 68 76.8 2,204 -21,221 13/ 1 24 21 68 76.8 2,204 - 29,480 4 480 13/ 1 24 21 68 76.8 1,193 - 11,491 13/ 1 24 21 68 76.8 1,193 - 16,578 5 data 960 13/ 1 24 21 68 76.8 9,243 - 89,005 13/ 1 24 21 68 76.8 9,243 - 101,961 6 mdf 264 13/ 1 24 21 68 76.8 2,649 -25,506 13/ 1 24 21 68 76.8 2,649 - 29,113 7 4,576 13/ 1 24 21 68 76.8 2,442 - 23,517 13/ 1 24 21 68 76.8 2,442 - 68,385 8 lobby -1 1,024 13/ 1 24 21 68 76.8 615 -5,926 13/ 1 24 21 68 76.8 615 - 15,994 Zone 1 Total /Ave. 9,992 24 21 68 76.8 22,466 - 216,333 24 21 68 76.8 22,466 - 321,260 Zone 1 Block 9,992 13/ 1 24 21 68 76.8 22,466 - 216,333 13/ 1 24 21 68 76.8 22,466 - 321,259 9 384 13/ 1 24 21 68 76.8 395 -3,808 13/ 1 24 21 68 76.8 395 -7,651 10 1,536 13/ 1 24 21 68 76.8 3,724 - 35,859 13/ 1 24 21 68 76.8 3,724 - 52,099 11 768 13/ 1 24 21 68 76.8 2,204 - 21,221 13/ 1 24 21 68 76.8 2,204 - 29,480 12 1,152 13/ 1 24 21 68 76.8 3,158 - 30,409 13/ 1 24 21 68 76.8 3,158 - 42,737 13 4,576 13/ 1 24 21 68 76.8 2,442 - 23,517 13/ 1 24 21 68 76.8 2,442 - 68,385 14 lobby -2 1,024 13/ 1 24 21 68 76.8 615 -5,926 13/ 1 24 21 68 76.8 615 - 15,994 Zone 2 Total /Ave. 9,440 24 21 68 76.8 12,539 - 120,741 24 21 68 76.8 12,539 - 216,345 Zone 2 Block 9,440 13/ 1 24 21 68 76.8 12,539 - 120,740 13/ 1 24 21 68 76.8 12,539 - 216,345 System 1 Total /Ave. 19,432 24 21 68 76.8 35,005 - 337,074 24 21 68 76.8 35,005 - 537,605 System 1 Block 19,432 13/ 1 24 21 68 76.8 35,005 - 337,073 13/ 1 24 21 68 76.8 35,005 - 537,604 RECEIVED CITY OF TUKWILA MAR 2 0 1098 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 INTERNAL COOLING LOADS (At time of Space Peak) V 600 PAGE 6 Lights Lights Misc. Misc. Misc. Room Ret. Air Lites People People Peopl Space Space Ret. Air Misc. Room Sensible Sensible CLF Sensible Latent CLF Sensible Latent Sensible CLF Total Number Description (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) 1 1,966 0 1.000 979 979 1.000 1,311 0 0 1.000 5,235 2 7,864 0 1.000 3,917 3,917 1.000 5,242 0 0 1.000 20,940 3 3,932 0 1.000 1,958 1,958 1.000 2,621 0 0 1.000 10,470 4 2,457 0 1.000 1,224 1,224 1.000 1,638 0 0 1.000 6,544 5 data 4,915 0 1.000 2,448 2,448 1.000 163,200 0 0 1.000 173,011 6 mdf 1,352 0 1.000 673 673 1.000 44,880 0 0 1.000 47,578 7 23,427 0 1.000 11,669 11,669 1.000 15,618 0 0 1.000 62,382 8 lobby -1 5,242 0 1.000 2,611 2,611 1.000 3,495 0 0 1.000 13,960 Zone 1 Total /Ave. 51,154 0 1.000 25,480 25,480 1.000 238,005 0 0 1.000 340,118 Zone 1 Block 51,154 0 1.000 25,480 25,480 1.000 238,005 0 0 1.000 340,118 9 1,966 0 1.000 979 979 1.000 1,311 0 0 1.000 5,235 10 7,864 0 1.000 3,917 3,917 1.000 5,242 0 0 1.000 20,940 11 3,932 0 1.000 1,958 1,958 1.000 2,621 0 0 1.000 10,470 12 5,898 0 1.000 2,938 2,938 1.000 3,932 0 0 1.000 15,705 13 23,427 0 1.000 11,669 11,669 1.000 15,618 0 0 1.000 62,382 14 lobby -2 5,242 0 1.000 2,611 2,611 1.000 3,495 0 0 1.000 13,960 Zone 2 Total /Ave. 48,328 0 1.000 24,072 24,072 1.000 32,219 0 0 1.000 128,691 Zone 2 Block 48,328 0 1.000 24,072 24,072 1.000 32,219 0 0 1.000 128,691 System 1 Total /Ave. 99,482 0 1.000 49,552 49,552 1.000 270,224 0 0 1.000 468,809 System 1 Block 99,482 0 1.000 49,552 49,552 1.000 270,224 0 0 1.000 468,809 RECEIVED IA CITY OF. MAR 2 0 1998 PERMIT: CENTER Trane Air Conditioning Economics By: Comfort Plus HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 INTERNAL HEATING LOADS (At time of Space Peak) Lights Lights Misc. Misc. Room Ret. Air Lites People Peopl Space Ret. Air Misc. Room Sensible Sensible CLF Sensible CLF Sensible Sensible CLF Total Number Description (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) (Btuh) 1 0 0 0.000 0 0.000 0 0 0.000 0 2 0 0 0.000 0 0.000 0 0 0.000 0 3 0 0 0.000 0 0.000 0 0 0.000 0 4 0 0 0.000 0 0.000 0 0 0.000 0 5 data 0 0 0.000 0 0.000 0 0 0.000 0 6 mdf 0 0 0.000 0 0.000 0 0 0.000 0 7 0 0 0.000 0 0.000 0 0 0.000 0 8 lobby -1 0 0 0.000 0 0.000 0 0 0.000 0 Zone 1 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 Zone 1 Block 0 0 0.000 0 0.000 0 0 0.000 0 9 0 0 0.000 0 0.000 0 0 0.000 0 10 0 0 0.000 0 0.000 0 0 0.000 0 11 0 0 0.000 0 0.000 0 0 0.000 0 12 0 0 0.000 0 0.000 0 0 0.000 0 13 0 0 0.000 0 0.000 0 0 0.000 0 14 lobby -2 0 0 0.000 0 0.000 0 0 0.000 0 Zone 2 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 Zone 2 Block 0 0 0.000 0 0.000 0 0 0.000 0 System 1 Total /Ave. 0 0 0.000 0 0.000 0 0 0.000 0 System 1 Block 0 0 0.000 0 0.000 0 0 0.000 0 RECEIVED OITY OF TUK v; A MAR 2 0 1998 PERMIT CENTER V 600 PAGE 7 Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 1 -9 -1.8 -24 -1.6 4,560 2 112 7.3 281 7.5 59,520 3 -41 -5.3 -83 -5.1 39,456 4 7 1.5 18 1.7 20,328 5 data 7 1.5 16 1.7 23,232 6 mdf 2 1.5 4 1.7 8,712 7 0 0.0 0 0.0 0 8 lobby -1 69 9.0 261 9.2 1,344 Zone 1 Total /Ave. 148 3.1 472 3.9 157,152 Zone 1 Block 417 8.9 1,085 9.1 78,504 9 -9 -1.8 -24 -1.6 4,560 10 112 7.3 281 7.5 59,520 11 -41 -5.3 -83 -5.1 39,456 12 17 1.5 40 1.7 55,176 BUILDING ENVELOPE COOLING LOADS (Wall - Window) (At time of Space Peak) V 600 PAGE 8 BUILDING ENVELOPE COOLING LOADS (Roof - Skylight) (At time of Space Peak) Roof Roof Skylight Skylight Return Air Roof Space Roof Skylight Skylight Skylt Return Air Skylt Space Skylt Sensible R.A. Sensible Space Return Air Space Solar Conduction R.A. Conduction Space Room Load CLTD Load CLTD Solar Solar CLF Load CLTD Load CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 2 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 3 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 4 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 5 data 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 6 mdf 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 7 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 8 lobby -1 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 Zone 1 Block 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 9 -54 -4.7 0 -4.5 0 0 0.000 0 0.0 0 0.0 10 1,770 38.4 0 38.6 0 0 0.000 0 0.0 0 0.0 11 -371 -16.1 0 -15.9 0 0 0.000 0 0.0 0 0.0 12 -162 -4.7 0 -4.5 0 0 0.000 0 0.0 0 0.0 13 5,767 42.0 0 42.2 0 0 0.000 0 0.0 0 0.0 14 lobby -2 1,208 39.3 0 39.5 0 0 0.000 0 0.0 0 0.0 Zone 2 Total /Ave. 8,158 28.8 0 29.0 0 0 0.000 0 0.0 0 0.0 Zone 2 Block 7,961 28.1 0 28.3 0 0 0.000 0 0.0 0 0.0 System 1 Total /Ave. 8,158 28.8 0 29.0 0 0 0.000 0 0.0 0 0.0 System 1 Block 7,961 28.1 0 28.3 0 0 0.000 0 0.0 0 0.0 Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plena Space Space Space Return Air Solar Space Space Return Air R.A. Room Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 0 0.900 -558 -8.3 0 0.0 0 1.000 833 3.1 0 0.0 0 1.000 -1,919 -11.9 0 0.0 0 0.990 -781 -8.3 0 0.0 0 0.990 -892 -8.3 0 0.0 0 0.990 -335 -8.3 0 0.0 0 0.000 0 0.0 0 0.0 0 1.000 -167 -6.2 0 0.0 0 0.993 -3,818 -5.0 0 0.0 0 0.536 1,915 2.5 0 0.0 0 0.900 -558 -8.3 0 0.0 0 1.000 833 3.1 RECEIV 0.0 0 1.000 - 1,919 - 11.9IN OF TU ILA0.0 0 0.990 -2,119 -8 MAR 2 0 ,0900.0 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus COOLING LOADS AT SPACE PEAK - ALTERNATIVE 1 Room Number Description BUILDING ENVELOPE COOLING LOADS (Wall - Window) (At time of Space Peak) V 600 PAGE 9 Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plenm Space Space Space Return Air Solar Space Space Return Air R.A. Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 13 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 14 lobby -2 69 9.0 261 9.2 1,344 0 1.000 -167 -6.2 0 0.0 Zone 2 Total /Ave. 149 3.1 473 3.9 160,056 0 0.993 -3,930 -5.0 0 0.0 Zone 2 Block 424 8.9 1,098 9.1 78,864 0 0.528 1,949 2.5 0 0.0 System 1 Total /Ave. 297 3.1 946 3.9 317,208 0 0.993 -7,748 -5.0 0 0.0 System 1 Block 841 8.9 2,183 9.1 157,368 0 0.532 3,864 2.5 0 0.0 BUILDING ENVELOPE COOLING LOADS (Exposed Floor - Partitions - Infiltration) (At time of Space Peak) Exposed Expsd Plenm Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Room Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total Number Description (Btuh) (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 1 0 0.0 0 0.0 0 0 0 75.2 23 3,992 2 0 0.0 0 0.0 0 0 0 75.2 92 60,839 3 0 0.0 0 0.0 0 0 0 75.2 46 37,459 4 0 0.0 0 0.0 0 0 0 75.2 29 19,602 5 data 0 0.0 0 0.0 0 0 0 75.2 58 22,421 6 mdf 0 0.0 0 0.0 0 0 0 75.2 16 8,399 7 0 0.0 0 0.0 0 0 0 75.2 275 275 8 lobby -1 0 0.0 0 0.0 0 0 0 75.2 61 1,569 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0 75.2 600 154,554 Zone 1 Block 0 0.0 0 0.0 0 0 0 75.2 600 82,521 9 0 0.0 0 0.0 0 0 0 75.2 23 3,938 10 0 0.0 0 0.0 0 0 0 75.2 92 62,609 11 0 0.0 0 0.0 0 0 0 75.2 46 37,088 12 0 0.0 0 0.0 0 0 0 75.2 69 53,021 13 0 0.0 0 0.0 0 0 0 75.2 275 6,042 14 lobby -2 0 0.0 0 0.0 0 0 0 75.2 61 2,776 Zone 2 Total /Ave. 0 0.0 0 0.0 0 0 0 75.2 567 165,473 Zone 2 Block 0 0.0 0 0.0 0 0 0 75.2 567 90,862 System 1 Total /Ave. 0 0.0 0 0.0 0 0 0 75.2 1,167 320,027 System 1 Block 0 0.0 0 0.0 0 0 0 75.2 1,167 173,383 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 Room Number Description 1 2 3 4 5 data 6 mdf 7 8 lobby-1 Zone 1 Total /Ave. Zone 1 Block 9 10 11 12 13 14 lobby -2 Zone 2 Total /Ave. Zone 2 Block System 1 Total /Ave. System 1 Block Room Number Description 1 2 3 4 5 data 6 mdf 7 8 lobby -1 Zone 1 Total /Ave. Zone 1 Block 9 10 11 12 BUILDING ENVELOPE HEATING LOADS (Roof - Skylight) (At time of Space Peak) Roof Roof Return Air Roof Space Roof Skylight Sensible R.A. Sensible Space Return Air Load CLTD Load CLTD Solar (Btuh) (F) (Btuh) (F) (Btuh) 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 -503 -43.6 -2,010 -43.6 -1,005 -43.6 -1,508 -43.6 -5,990 -43.6 -1,340 -43.6 - 12,356 -43.6 - 12,356 -43.6 - 12,356 -43.6 - 12,356 -43.6 Wall Wall Plenum Plena Load CLTD (Btuh) (F) -230 -43.6 -670 -43.6 -335 -43.6 -209 -43.6 -209 -43.6 -63 -43.6 0 0.0 -335 -43.6 -2,052 -43.6 -2,052 -43.6 -230 -43.6 -670 -43.6 -335 -43.6 -503 -43.6 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 -44.0 0 -44.0 0 -44.0 0 -44.0 0 -44.0 0 -44.0 0 -44.0 0 -44.0 0 -44.0 0 -44.0 BUILDING ENVELOPE HEATING LOADS (Wall - Window) (At time of Space Peak) Wall Wall Space Space Load CLTD (Btuh) (F) -665 -44.0 -1,647 -44.0 -718 -44.0 -475 -44.0 -422 -44.0 -95 -44.0 0 0.0 -1,246 -44.0 -5,269 -44.0 -5,269 -44.0 -665 -44.0 - 1,647 -44.0 -718 -44.0 - 1,024 -44.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Skylight Skylight Skylight Skylt Return Air Skylt Space Skylt Space Solar Conduction R.A. Conduction Space Solar CLF Load CLTD Load CLTD (Btuh) (Btuh) (F) (Btuh) (F) 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 V 600 PAGE 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Glass Glass Glass Glass Glass Glass Glass Space Return Air Solar Space Space Return Air R.A. Solar Solar CLF Conduction CLTD Conduction CLTD (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) -3,098 -44.0 0 0.0 - 12,392 -44.0 0 0.0 -7,435 -44.0 0 0.0 -4,337 -44.0 0 0.0 -4,957 -44.0 0 0.0 -1,859 -44.0 0 0.0 0 0.0 0 0.0 - 1,239 -44.0 0 0.0 - 35,316 -44.0 0 0.0 - 35,316 -44.0 0 0.0 - 3,098 -44.0 0 0.0 - 12,392 -44.0 0 0.0 RECEIV D - 7,435 -44.00�T( OF T VALNv -11,772 - 44.0 CAT( 0.0 MAR 2 0 1998 PERMIT CENTE:'3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C Trane Air Conditioning Economics By: Comfort Plus HEATING LOADS AT SPACE PEAK - ALTERNATIVE 1 BUILDING ENVELOPE HEATING LOADS (Wall - Window) (At time of Space Peak) V 600 PAGE 11 Wall Wall Wall Wall Glass Glass Glass Glass Glass Glass Glass Plenum Plenm Space Space Space Return Air Solar Space Space Return Air R.A. Room Load CLTD Load CLTD Solar Solar CLF Conduction CLTD Conduction CLTD Number Description (Btuh) (F) (Btuh) (F) (Btuh) (Btuh) (Btuh) (F) (Btuh) (F) 13 0 0.0 0 0.0 0 0 0.000 0 0.0 0 0.0 14 lobby -2 -335 -43.6 -1,246 -44.0 0 0 0.000 -1,239 -44.0 0 0.0 Zone 2 Total /Ave. -2,073 -43.6 -5,301 -44.0 0 0 0.000 - 35,936 -44.0 0 0.0 Zone 2 Block -2,073 -43.6 -5,301 -44.0 0 0 0.000 - 35,936 -44.0 0 0.0 System 1 Total /Ave. -4,126 -43.6 - 10,571 -44.0 0 0 0.000 - 71,252 -44.0 0 0.0 System 1 Block -4,126 -43.6 - 10,571 -44.0 0 0 0.000 - 71,252 -44.0 0 0.0 BUILDING ENVELOPE HEATING LOADS (Exposed Floor - Partitions - Infiltration) (At time of Space Peak) Exposed Expsd Plena Ceiling Floor Floor Partition Part. Infilt. Infilt. Infilt. Dry B Sensible Envelope Room Sensible CLTD Sensible CLTD Airflow Sensible Latent Temp. Load Total Number Description (Btuh) (F) (Btuh) (F) (Cfm) (Btuh) (Btuh) (F) (Btuh) (Btuh) 1 0 0.0 0 0.0 0 0 0 67.6 -45 -4,039 2 0 0.0 0 0.0 0 0 0 67.6 -180 - 14,889 3 0 0.0 0 0.0 0 0 0 67.6 -90 -8,578 4 0 0.0 0 0.0 0 0 0 67.6 -56 -5,078 5 data 0 0.0 0 0.0 0 0 0 67.6 -112 -5,701 6 mdf 0 0.0 0 0.0 0 0 0 67.6 -31 -2,048 7 0 0.0 0 0.0 0 0 0 67.6 -536 -536 8 lobby -1 0 0.0 0 0.0 0 0 0 67.6 -120 -2,940 Zone 1 Total /Ave. 0 0.0 0 0.0 0 0 0 67.6 -1,169 - 43,808 Zone 1 Block 0 0.0 0 0.0 0 0 0 67.6 -1,169 - 43,808 9 0 0.0 0 0.0 0 0 0 67.6 -45 -4,541 10 0 0.0 0 0.0 0 0 0 67.6 -180 - 16,900 11 0 0.0 0 0.0 0 0 0 67.6 -90 -9,583 12 0 0.0 0 0.0 0 0 0 67.6 -135 - 14,942 13 0 0.0 0 0.0 0 0 0 67.6 -536 -6,525 14 lobby -2 0 0.0 0 0.0 0 0 0 67.6 -120 -4,281 Zone 2 Total /Ave. 0 0.0 0 0.0 0 0 0 67.6 -1,105 - 56,772 Zone 2 Block 0 0.0 0 0.0 0 0 0 67.6 -1,105 - 56,771 System 1 Total /Ave. 0 0.0 0 0.0 0 -1 0 67.6 -2,274 -100,580 System 1 Block 0 0.0 0 0.0 0 0 0 67.6 -2,274 - 100,579 RECEIVED CITY OF TUKWILA MAR 2 0 1998 PERMIT CENTER Trane Air Conditioning Economics By: Comfort Plus BUILDING U- VALUES - ALTERNATIVE 1 BUILDING U- VALUES Room U- Values Room Room (Btu /hr /sqft /F) Mass Capac. Room Summr Wintr Summr Wintr (lb/ (Btu/ Number Description Part. ExFlr Skylt Skylt Roof Windo Windo Wall Ceil. sqft) sqft /F) 1 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 122.8 24.30 2 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 84.1 16.66 3 0.000 0.000 0.000 0,000 0,000 0.560 0.587 0.050 0.317 77.7 15.39 4 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 80.3 15.90 5 data 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 44.2 8.77 6 mdf 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 41.4 8.22 7 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.317 13.3 2.67 8 lobby -1 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 85.7 16.98 Zone 1 Total /Ave. 0.000 0.000 0.000 0.000 0.000 0.560 0.587 0.050 0.317 47.7 9.46 9 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 174.9 35.62 10 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 136.3 27.99 11 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 129.8 26.71 12 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 127.7 26.29 13 0.000 0.000 0.000 0.000 0.030 0,000 0.000 0.000 0.317 65.5 13.99 14 lobby -2 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 137.9 28.30 Zone 2 Total /Ave. 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 102.1 21.24 System 1 Total /Ave. 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 74.2 15.18 Building 0.000 0.000 0.000 0.000 0.030 0.560 0.587 0.050 0.317 74.2 15.18 V 600 PAGE 12 BUILDING AREAS BUILDING AREAS - ALTERNATIVE 1 Trane Air Conditioning Economics V 600 By: Comfort Plus PAGE 13 Floor Total Exposed Number of Area /Dupl Floor Partition Floor Skylight Skl Net Roof Window Win Net Wall Room Duplicate Room Area Area Area Area /Rf Area Area /W1 Area Number Description Flr RI (sqft) (sqft) (sqft) (sqft) (sqft) ( %) (sqft) (sqft) ( %) (sqft) 1 1 1 384 384 0 0 0 0 0 120 23 408 2 1 1 1,536 1,536 0 0 0 0 0 480 31 1,056 3 1 1 768 768 0 0 0 0 0 288 38 480 4 1 1 480 480 0 0 0 0 0 168 35 312 5 data 1 1 960 960 0 0 0 0 0 192 40 288 6 mdf 1 1 264 264 0 0 0 0 0 72 50 72 7 1 1 4,576 4,576 0 0 0 0 0 0 0 0 8 lobby -1 1 1 1,024 1,024 0 0 0 0 0 48 6 720 Zone 1 Total /Ave. 9,992 0 0 0 0 0 1,368 29 3,336 9 1 1 384 384 0 0 0 0 384 120 23 408 10 1 1 1,536 1,536 0 0 0 0 1,536 480 31 1,056 11 1 1 768 768 0 0 0 0 768 288 38 480 12 1 1 1,152 1,152 0 0 0 0 1,152 456 40 696 13 1 1 4,576 4,576 0 0 0 0 4,576 0 0 0 14 lobby -2 1 1 1,024 1,024 0 0 0 0 1,024 48 6 720 Zone 2 Total /Ave. 9,440 0 0 0 0 9,440 1,392 29 3,360 System 1 Total /Ave. 19,432 0 0 0 0 9,440 2,760 29 6,696 Building 19,432 0 0 0 0 9,440 2,760 29 6,696 ASHRAE 90 ANALYSIS - ALTERNATIVE 1 ASHRAE 90 ANALYSIS Overall Roof U -Value = 0.030 (Btu /Hr /Sq Ft /F) Overall Wall U -Value = 0.199 (Btu /Hr /Sq Ft /F) Overall Building U -Value = 0.115 (Btu /Hr /Sq Ft /F) Roof Overall Thermal Transfer Value (OTTVr) = 0.40 (Btu /Hr /Sg Ft) Wall Overall Thermal Transfer Value (OTTVw) = 25.32 (Btu /Hr /Sq Ft) 'RECEIVED lUKWILA Cfl'`� MAR 2 0 19 PERMIT Dear Sir: City of Tukwila Fire Department Fire Department Review Control #M98 -0059 (512) March 25, 1998 Re: Boeing Employees Credit Union - 655 Andover Park West The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled, by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Call the Tukwila Fire Department at 575 -4407 for John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 Yours truly, cc: TFD file ncd City of Tukwila Fire Department Page number 2 approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. The Tukwila Fire Prevention Bureau John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (2o6J S7S4404 • Fain (206) S75-4439 1161111 LIII ■ i ! 1 f'1 111111 � 7 1-1IIR I l u ' ®� I 11111 tAA 200 -, 211 1 1200 11.11111P 11.11 VIII VIII VIII VIII I,p, n■INI/n irla - { 200 SEC 2;8 I - `CORRIDOR 7216 \\ 1,111 f/ ' JR J ` I ti Li 1209 IRMO ��� IP I'I I I_I� U _ �IFr� FF 100 - AEI � _ 1QC. I` I I ' ,, 2 = TTT ,. L ,11 IIIro :E^� i ��JI�I����'�� E I 1111' 'I ■I IIII i.&F !!• 1 �I II II ; � { 2 . ' • •- nn11 o 1l�EI II! IrI!1 -ll1�' II! 'iIILI i_ ! n! J 1 Li �� !11111 \ \ \\ I - -I III {2d7m l 111 ■II11nUL-0 I,,,. ± I - °Ill) 1161.111101 R. EMEMMMoa. iiI IIIIIIIII i1IIIIIJIII Iln VIII'! IlEI 0111110 ,1� Car .11 1111 �� I. XI1 :4Y& I - � it li;N •0� -e I�1 ME ■CQl6 I 41111111111311111111NIE WNW °INW _ t �IIlI IIiIIInI1flhI1 1111'g'e I I_I � I�� ' b " ' 11II � III!II1 _!.,■I!!! NI .1III I!I!!S I , ' °! _ 1 k i911 ■1E ri ` ©�1 ielign I nil.'!. ll 1IIIIIPi11111111!� IlnINn I Et 111 VIII:,' 1 I I��I IlIII�l1 \ll 2 E. 'I { a �__� { I I } -- 'air "II .. IL■i , i il1®®P!II's_ .. I 00{ ,, . 7i1�V i ' , n ■ 11,1! �N � _ - 11111!0 �rlll "�� 4 WI � l� ll MI I e:. o. nn�l 00 ® j it.... " g al � I IF . -� I _ 1 8 1 IF gill' I — I —I . 0 ! T I_I _ ` U I_I _ �I - 1, JO. ,1 I DN,111. FRONDE m/918LATED 91$ -BASE FRONDE w /N8IATED 01.6 -BABE . 1 PROVIDE wM8JL 4 ED WM BASE UPPER FLOOR PLAN I(B - -0 Mq 005'? S -DRAGE 7206 I CONFERENCE 202 I ON , J\ STERAGE I 22 7 E f 4� 4n i ,.� r Y{ iFirmilmTliffordi inalaimmiE iIIII��,I�E it L�v�i ®1;51L1Y.��i -► ii IIIlIn! : 1iiiil'IIi I I9�_ �i'JIill�tll� lk ©� f�;en fl ® ■L \■ "' 1� Ex I!I!k- tai /EL Er IS DF MI ■IliFeel�1 �■1 FI f \I os ;; I�j u MEd :Mir III!IIIII �llln ■L n ■�I _I_o,■.i_o4■ ® wring,,-......., --1t= t4ii�f1 Mail� larlit, ■11` 40 iasi i ■� ■ ■i I ' ® '1 � , I . 1 m r � �rdarr - •4G !I!1 -I ' L0" l! III ®I�, �f��� rtL n � I ®I® (.I 11 11111 111)". �� ®lI QL. lia / L r F£ I Ii 1, L'iRSG 110 • All■ ®I[�1, 1'L I � ■i �_1® � f � 1v l� 11■i ip ■ ° '!l iU T rea l ®E'iJFP■ !IIIU11101I1 1 ■I I III iM adai Nh�It k � u �I�1!®' ■ � 111 1 141 I A I L 1�, -_ }� � I_ Il'1111111 1 � �GICIV 7 III , ' ®. "' 1iii � r, i IN , 1ll III in r I.I L°J = �JJ1 � e a�o • • - I 11 " c 1: pllllll �� � . I ll!. ' �;iiiIY�llnl iiiiilln ®i ®ini I E1 IIIIIIInI' VAIII■IN 1111TH ■.,,,, IIInIIil lI!' PH N y ■Iim! P ; 1 51 11■Ii®g■� 1��1®i®■■ ®� Inc ii1 STAIR 4I '•. 7 rrr �..... y■ ,�I ■r�*en 1 7115.. �■I _ Qfi■ .!� �i /LL�I ®����:�1� IA: I�rlTi r I -i i I, w \O Y!• ■'i�?:'1 i'1 ,r.; t ■�I■cr1� 1 1 ■„ ■ ■. ■ 1 n ll ■■ oh 2 'll 1111 JII \ \` U\ d�Ul u �In' IIn9f1■■11■,1■■11 PROVIDE a/RNeULATED 816 -BABE STORAGE CORRIDOR FR7NDE LOWER FLOOR PLAN KEY PLAN II NOTE& 0 0 0 0 0 O 0 RETURN AIR TRANSFER ASSEMBLY w/GRD SIZE INDICATED. FOR 24'. x 0' GRILLES, INTERCONNECTING DUCT $HALL BE 04. FOR 24' x 24' GRILLES FR NDE 164 DUCT. - (i(=bo"1 A'iN (kl'I'149/1 - ( S "� `'f�l I7. `1°cw /3CO24+- ® 604 - 4 °`-- U =161-1 M/N QDFZ SL, 101 02 103 104 a 105 � 106 2 401 195 W 199 110 III 112 IB 144 201 202 .03 204 205 206 .0l 208 .10 211 VICINITY MAP N.7 B. SEPARA:- F=RWT RL0006._2, FOR: MECHANICA `ELECTRICA ❑PLUMBING 0 GAS PIPING CRY OF 7UI AiLP. BUILDI DIVISION 3/295 1 NUMBER DATE R E V I S I G N S SCALE AB NOTED DATE 3/2/95 CONTR. NO, CHECKED EY: CITY OF TU 24'x 24RAG (0R 241 URAG1 FOR LOCAL RETURN AIR TO VAV BOX GRILLE IS EX18T N 4 SHALL BE RELOCATED TO LOCATION INDICATED. EXTEND/PROVIDE NEW 164 DUCT FROM GRILLE TO EXISTN VAV BOX BERVNG THIS AREA PROVIDE VOL DMPR • VAV R4 MENIAL 24k 241RAG (OR 245/2 FOR GENERAL RA TO CENTRAL WIT. GRILLE 18 EXIST* 4 GULL BE RELOCATED TO LOCATION PAICATED. EXTEND/FRONDE NEW 18'4 DUCT FFSM1 [-RUE TO mere C511R RA DUCT. FRONDE VOL OMPR • MAN TRIM RELOCATED T -BTAT. VERIFY ACTUAL LOCATION ON SITE w/CPI EM PRIOR TO ROUGH -N. RELOCATE EXSTG FP/AVNAV BOX AS INDICATED. EXTEND EXISTS SUPPLY AIR DUCT AS REDO. NEW FAN IrClleRFD VAV (FPVAV) OR COOLING ONLY (VAV) NOX PRCMDE CONNECTION TO EXISTG PRIMARY SUPPLY AIR DUCT AS REOD, SIZE PER BOX INLET: FRO/CE :USURP, I RETURN AR PLENUMS AS INDICATED. SIZE BOX AS INDICATED CN 8C RDD E BELOW. RiNOVE EDRTING EC:AR ENT 4 RETURN TO CURER. RENOYE DOWNSTREAM DUCT 4 GAO,. CRIRNY€ 0 -100 01 -200 20 - 350 351 - 500 50 - 680 681 - 880 881 - 105 TTPMATV MI1■9CLER BLVD DIFFUSER SCHEDULE CD DOOR SIZE z 6' B x 8' 10'z 10' 0 , 0' 14 x 14 16'x16' IS' I IB' VAV SCHEDULE rvo4P/MOD TDIYII5TER0F51500 KRIEGER/L.5 NDUCTO/ NDICTO/ NDUCT0/ NDUCTO/ INDUCTO/ NDUCTOAF52000 REDDI/ REDDI/ ADUCT0/31F5 INDUCTOAF51500 INDUCT/3i REDDI/ INDUCT!, NDUCTOAF52060 TIN9r1MFV REDDY INDUCTO/ T11162 ,v 1509 1500 0 600 - 600 1209 1600 2000 2 c 6 45013 1200 600 5 2110 1200 115 4803 000 4 000 4 1500 11 000 13 400 600 4000 0 2000 22 000 0 200 2 1200 n 000 4 DUCT/SPIN-14 SIZE 6'4 5'4 12 4 04 144 H'4 16 45013 VAV C DUCT COIL 4505 vAV w/ELEC DUCT COIL 450/3 FP'vAv 2110 VAV w/ELEC DUCT COILS 2112 2112 480/3 480/3 2110 251/1 450/3 2110 2110 480/3 212 VAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL ANEW FPVAV NEUI FPVAV VAV w/ELEC DUCT COIL vAV w/ELEC DUCT COIL VAV w/ELEC DUCT COIL REPLACE EXISTS VAV BOX vAV w/ELEC DUCT. COILS REPLACE EXISTS DAV BOX VAV w/ELEC DUCT COIL ' /AV w/ELEC DUCT COIL NEW FPVAV ' EXHAUST FAN' SCHEDULE F884 2 -0, 40 CRt • 125 SP 130 WATTS, 1202, 000 RPM w2NTEGRAL BAOa7RAFT D11 MIT MINTED SPEED 814TC4 I 04 DUCT UP TO ROOF 1000. CONTROL wuREVERSE ACTING TFERIOSTAT SET TO ACTIVATE FM • 15' F. (ADJUSTABLE/. UNIT 225 36h. KM 2-0, 40 CRt • 125' SP, 80 WATTS, 002, 000 RR/ at/INTEGRAL BAOCRAFT DMPR WIT MINTED SPEED 81T04 4 5 MN DELAY TIMER COOECTED TO LIGHTS. LIGHTS TO ACTVATE FAN ■/DELAY TFER 84112 OF. WIT 1102 36.8 PEN4 2-0,9S5 011 . 125' SP, 265 WT8, 901,1150 RPM w/INTEORAL BAOCDRAFT DMPR WIT MINTED SPEED SWITCH 4 IN -LINE CCFOlR PON P8EL8. CONTROL wl1-DAY FROGRUMI IAELE THE CLOCK- SET E PER OUNER. WIT DST • 50••. FILE e s does nv 1 dged. 1 nCO e ced L/ ■ NIMISM EMERII MOw FORT s. 6617 S. 193rd Place, Suite #P105 III KENT, WA 98032 Q 425 251 -9840 (42 -9871 (Fax) Corporate Square Building 0 1 Southcenter Corporate Square Andover Park West Tukoala, 004 Hear' Floor Plans - Bldo 1 u MAR 2 0 199a PERMIT CENTER M - I