HomeMy WebLinkAboutPermit M98-0073 - METRO ONE TELECOMMUNICATIONSt__Pc)o) r o 9 kro.lunuuocro\-, uQ Q24 City of f Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0073 Type: B -MECH Category: NRES Address: 555 ANDOVER PK W Location: BUILDING 4 - FLOOR 1 Parcel #: 262304 -9075 Contractor License No: COMFOP *064D2 TENANT METRO ONE TELECOMMUNICATIONS 555 ANDOVER PK W, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTRACTOR COMFORT PLUS PO BOX 913, KENT WA 98032 CONTACT HERB JACKSON 6617 S 193 PL, P -105, KENT WA 98032 * ** ** * * ** * * * * * * * ** ** **** *fit ** ** 4************* Fr* * .t� * *. ** * tk * ** * *** * *** ** ** * * ** Permit Description: 4. NEW VAV BOXES, INSTALL -OWNER SUPPLIED - SPLIT A/C UNITS, REWORK AIR DISTRIBUTION. INSTALL LIEBERT UMC Edition: 1994 Signet Print Name. MECHANICAL PERMIT Valuation: Total Permit Fee: Date: tta. ,Title: (206) 431 -3670 Status: ISSUED Issued: 04/27/1998 Expires: 10/24/1998 Phone: 206 575 -2120 Phone: 206 251 -9840 Phone: 425 - 251 -9840 530.00 81.88 ******* k*****• k******** * * ** * * * * * * *. * * *' ** * * *** * * * * * * ** Perm t Ce r Authorize ed "Si.gnature D "ate I hereby certify that I have read and examined this permit and know; the same to be true and correct. All `provisions of law and ordinances, governing this work will be complied with., whether specified. herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o th •erfo nanc. of work. I am`.authorized to sign for and obtain this buildi • perm t. This permit shall become null. and void if the. work .is not commenced within 180 days from the date of issuance, .or •i,f tie, w;o'rk is suspended or abandoned for a period of 180 days fr.om':: .the `l'ast inspection. Project Name/Tenant: /vi U c a-P .6f r5T Value of Construction: 4 311.36. 00 ,•� Will there be storage of flammable /combustible hazardous material in the building? El ts yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Site Addr ss: City State /Zip: 6515 s� t �- l- c(�J. rt�w JI& j OJ &.- 98188 Tax Parcel Number: Z0/)4 --' o15' Phone: -- Property Owner: � Address: Street Address: (4ilvtn'e.i 5 - r * Z$z09 c r -- / —� a r 11 Cit State /Zip: tJ . t: C Fax It: Phone: q _ 9 / Contact Person: Street Address: -1 . (1: Contractor: — e5 City State /Zip: r~. t 42.1, Z Fax #: 4 - Phone: Street Address: - I 5o. 7> . P--105 City State /Zip: ■ a. ':. z Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BYAPPLWANT) Description of work to be done: 20, • ft,e; - U ' i ow t,S K a- O (A et b'' Z urp / t %'r S f_ C- th . rr «s-k 4.f •- d cl. ►-i t. sA►= e+vt . ,•� Will there be storage of flammable /combustible hazardous material in the building? El ts yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks El Antennas /Satellite Dishes ❑ Bul head /Docks El Commercial Reroof ❑ Demolition ❑ Fence echanical El Manufactured Housing - Replacement only ❑ Parking Lots El Retaining Walls El Temporary Pedestrian Protection /Exit Systems El Temporary Facilities El Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application Address: MISCPMT.DOC 7/11/96 CITY OtTUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188. (206) 431 -3670 OR STAFF USE ONLY Project Number: Permit Number: Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT• MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping El Flood Control Zone ❑ Landscape Irrigation El Storm Drainage ❑ Water Meter /Exempt If El Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous El Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application expire 0 I f Date application a4 +is led: Phone: City /State /Zip: Applicatifi men by: (initials) BUILDING OW R 0 R A `THO • ZED A ENT: Signat - __ e , • t c1l /- I "P- I - City State Date: It it ��� + /Zip: Submit checklist' No: M - . ' . Print name: MI drtii , .x 4 -Cy I/ k. 4 63 1 037-- Address: fir- in SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist No :. M -9 0 Antennas /Satellite Dishes Submit checklist' No: M - . ' . in Awnings /Canopies - No signage Commercial' Tenant Improvement '• . Permit ri Bulkhead/Dock Submit checklist : No M-10 0 . Commercial Reroof Submit checklist No M=6.- in Demolition Submit checklist; No;:. °M -3,: M =3a ri Fences - Over 6 feet in Height Submit checklist No M -9' 0 Land Altering/Grading/Preloads Submit checklist. No: M -2 in Loading Docks Commercial Tenant Improvement Permit... Submit Checklist-No: H -17 gr Mechanical (Residential & Commercial) , Submit checklist: NO. - M= 8 ';'.: Residential only -'H -6, H -16 in Miscellaneous Public Works Permits Submit checklist No H -9 ; 0 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist , No: M -5 Moving Oversized Load /Hauling Submit checklist ., No M -5 ' 0 Parking Lots Submit checklist No: M -4 in Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist . No:. M -6r LJ Retaining Walls - Over 4 feet in height Submit checklist No M1: Temporary Facilities Submit checklist :: No:., M in Temporary Pedestrian Protection/Exit Systems Submit checklist No NU El Tree Cutting Submit checklist No:. M ALL MISCELLANEOUS PER T APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING: ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN `B1JIL.t31NQ �T'E PItaNS AND UTILITY PLANS ARE TO BE COMBINED ARCHITECTURAL DRAWINGS: REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer ; or..contractor.liconsed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC, '7/11/96 n r.' • 't ') a y ,,r 4110.1 ofoloWW . CITY OF TUKWILA Permit No: • Status: Applied: Issued: M98-0073 ISSUED 04/09/1998 04/27/1993 Address: 555 ANDOVER PK W Suite: • Tenant: METRO ONE TELECOMMUNICATIONS Type: B-MECH Parce;i #: 262304-9075 *%*****A**k*************k********k****************A*A*******k****k********* Permit Conditions: 1 . No changes w i l l be made to the plans unless approved by the. Architect or Engineer and tha—Ty)::.y.i,la, Building Division. 2 All permits, inspecttohl plans shall be available at the job site pr lot to the stvt of any con struct i on . Th9„§-4;t1dcilmehts are to be ma iita avail- able until f ifiwA'n s 6c '4315, p royal i s 3, Al 1 c on s t uWon to e done Z1 ha 6n 4 rr a n gOrItIved p1 ans and404 64 the ,pp)forM BO) 4frn 94 E d i t i o n ) . s amend Uniform 'Me chail Code-q1-9944,,Edl'ej on ) and Washington State Energy Code (1994 E'61,t 4 Validity Permit. The i ssuance of a permit or,approVaP„of plans,,,rspecifications, and computations shall not , b*, be a permit ..'fpr', or an approval of, any vi�lat in' of any of : the provisions of the building code or other i ordinance of the jurisdiction:; No permit presuming giVe:" to v 1 ate or canoe 1 the provisions .z.of this Y-1! colia- shall be va 1 5. MANUFACTURERS' INSTALLATION TR IN ,UCTIPNS-REOUIRED ON `SIT , , Fo0 , q‘ ).':, .',!. .,,, ,-,„ , y . ' ' • ,.. .. . /. , ■ .. ',.. . i ( ,,. „, 8 . ,,, . .,,,::F /1.) ''''''':11.'1 7 • i • ,,„j;'.i' 1 .1.„,„ I 01 ?'•":' .;,, . 't'' i • ,., , . • '0;4 t , 46 ••••:;. - j ,. '• - 1 , ;,,,. ' . A 1 ,-.';' , ?) ,: • Vif U ,... i . i... ,.., • ( ;.,' ,1,-• , . ''... ,,: • . .,..., , , • i ...::: ,.• ; V'c ' -', •"! ••• ; . t. f.o, '',1 ,•,-'.. , ,, ,..,, • . • i ii,' ''.' ' 1 4 , 0. 4 ' ' i. ). , '.a .‘ ";.V i.4 . • ill''? ‘ - .. i !•• ''',.• .• i • I • 3! • • ,,, -i. • 7i „ t q .,-; • ... . ., • .:, - • • •ed • ,...4,- •,,,,,, . . „.: ,...c,f - • /0 46 , 774 2 j / v 1 1 ):: 4....,!1rt9 ' / /.• • ( : fl: • . , • . . ) t +;', i „;;. T., •'•' 4 ' ' •''' ' '-,? : • ''. :. C C PL E.4'*ti4' A V O UTIN SLIP ACTIVITY NUMBER: M98 -0073 PROJECT NAME: METRO ONE CORPORATE SQUARE DEPARTMENT: Building Division E u � 1 � ❑ lic Wor s u- \11 -CfSb Complete Comments: TUES /THURS ROUTING: Routed by Staff 00 Fi e Prevention Struc.tal DETERMINATION OF COMPLETENESS: (Tues, Thurs) Incomplete Please Route (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions E REVIEWERS INITIALS: CORRECTION DETERMINATION: Approved ❑ Approved with Conditions \PR•ROUTE.DOC 1/98 DATE: 4 -9 -98 Planning Division �CJJ Pe mit Codrdirfatdr Ljw DUE DATE: 4 -14 -98 Not Applicable No further Review Required DATE: DUE DATE: 4-28-98 Not Approved (attach comments) DATE: DUE DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: F625.052. 000 - (8/97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW : :AS CONST CONT SPECIALTY AA AF Pag i�:'�' ;NUMB CCAAAF COMFOP *06'4D2 ` 03/21'/1999 4EFF E CTIVE DATE { � �, O3/22/1994 COMFORT PLUS 6617: -S 193RD OK STE P 105• KENT WA 98032 -2197 Account .'Cod 000/045,.880 000/3;12'.100 % t { AL, *k4* * kA *A ,1 *111.710 ** *4 *•k *A•* * 4* R*•.\** 0*. 1f *•ki•k* * * * *•A **A ** *A *•k * *k *A * k* CITY OF TUKWILA, WA TRANSMIT * *i *A•k * * ** * * **.* * **•A ** * */* lr *A•F*? i * A�1•••A•h�1*.*'t ****k•ka*'* •* TRANSMIT Number: 89700754 Amount: 81.Si3 04/27/98 13:23 Payment Method: CHECK Notation: COMFORT PLUS mnitrr UP Permit Na: M98-0073 Type: B-MECH MECHFANICAL. PERMIT Parcel Nu, 26230.4 -9075 Site 'Address: 555 ANDOVER PK W Location: BUILDING r{ -- FLOUR 1 • Total Feos: 81.130. This •PEtymeht 81.88 Total ALL Pintss. 81 pil ' Balance: • .,00 ** **• h*****• A* i* 4i*' A*• kA****• kA** A*•**•h * *k *h* * * * * * + 4 • * * * * *fi Amount •16. 8 65.50 Description PLAN. CHECK —.NONRES MECHANICAL 7 NONRES Project: ciii. IN Type of inspecti• Address: ass A.g� Date called: t�!' r Special instructions: Date wanted: 5 O i�p._ bb a.m. p.m. Requester: 1,3� _ ) � Phone No.: C (COMMENTS: Inspector: - 1 I I Receipt No.: Approved per applicable codes. INSPECTION RECORD l Retain a copy with permi t pi) �� o07.3 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 s/ -3670 Corrections required prior to approval. ■(stM-IA ll�:k')' C.^'1 Date: s / cf $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd,; Suite 100. Call to schedule reinspection. Date: Project: N crit...z., / Type of inspection: Date callec: 4. _ 9 co Address: .65 .- i Li c p Special instructions: Date wanted: k _ ., 1 47 Requester Wak PtepeNo• , st--oce-0 4 Vt'eMPArtvr INSPECTION RECORD A " Retain a copy with permitA- I PERMIT NO. I ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 9818 I I Approved per applicable codes. COMMENTS: Inspector: e ' - **" 6 Ca (206) 431-3670 Corrections required prior to approval. Date: Zy 3 z $42.00 REINSPECT' N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Receipt No.: Date: kt,r. • Nbt .i /.•;:{:::: ; r ., ;, ; � on ac f F r �ti ` • ... {v C . . $•` ... : < . ' ;: :: * :::: > :;; : :.... `iii:. x :' '.';• ` y' :l + +. ` .x.r,• .L ? : n 1. ,), .•. . v• ,.;;• ;:; : <: ...r., }.. }.. . . Balance Due: $ 4� Sb Need Current Contractor Registration Card: ❑ Yes. XNo Need to Enter Contractor Information in Sierra: ❑ Yes X No TiTUS® Installation Manual Fan Powered Terminals $ Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage Is found, report it immediately to the delivering carrier. Store units in a clean dry location and do not stack more than four high. Caution: Do not use the inlet collar, damper shaft, flow sensor or air tubing as a handle to lift or move assembly. Damage to the unit or controls may result. Before installation, remove fan packing and all foreign material from the unit. Check the blower wheel for free rotation. Supporting the Assembly Suspend the unit from the building structure in a horizontal plane with the access panels facing downward. Do not obstruct the access panels with support channels or straps. One inch long sheet metal screws can be used to penetrate the casing (see figure 1). Use the support method prescribed for the rectangular duct on the job specifications. Unit may be equipped with optional hanging brackets (see Figure 2). Hanger rod up to 7 /16' diameter may be used. Note: If equipped with pneumatic controls, or unit is parallel fan type (Model MFV or FVL), the terminal must be mounted right side up. it must be level within ±10 degrees of horizontal, both parallel to the air flow and at the right angle of air flow. The control side of the terminal is labeled with an arrow indicating UP. Duct Connections Slip each inlet duct over the inlet collar of the terminal. Fasten and seal the connection by the method prescribed by the job specification. The diameter of the inlet duct "D" in inches must be equal to the listed size of the terminal; e.g. a duct that actually measures 8 inches must be fitted to a size 8 terminal. The inlet collar of the terminal is made 1/8 inch smaller than listed size in order to fit inside the duct ,,(see figure 1). important: Do not insert duct work inside the inlet collar of the assembly. Inlet duct should be installed in accor- dance with SMACNA guidelines. Rectangular discharge opening is designed for flanged duct connections. Fasten and seal by method prescribed in the job specification. If single -point electronic velocity sensor is used, 3 to 5 inlet duct diameters of straight duct should be provided at the terminal inlet. Minimum Access Fan Powered terminals require sufficient clearance to service the fan blower assembly and internal actuator (if so equipped) from the bottom of the unit, low voltage controls from the side of the unit, and line voltage motor controls or electric heat section (if so equipped) from the rear or discharge of the unit. For bottom access panel removal, 3" minimum vertical clearance below the unit is required, plus sufficient horizontal clearance to slide the access panel clear of the bottom of the unit. Horizontal clearance Is dependent on access panel dimensions as indicated on product submittals. Discharge Figure 1 Access Panel (Entire Bottom is Removeable) Hanger Rod ptional Hanger Bracket Figure 2 B-FPIM 1 -1 -95 Note: Access panel for low temperature terminals is one piece, the full length and width of the unit. Make appropriate accommodations for panel removal. Generally fan terminal casings are of • sufficient size to allow adequate service room for components mounted internally once panels are clear. For low voltage control enclosure access, a minimum of 18' is recommended. Specific control enclosure location is indicated on product submittals. Panel for low voltage enclosures are removable (not hinged). For line voltage motor controls or electric heat control access, a minimum of 36' should be provided, to allow full opening of hinged access doors. Specific location is indicated on product submittals. Important: These recommendations do not preclude NEC or local codes that may be applicable, which are the responsibility of the installing contrac- tor. Air Flow V Air Flow CI1yncS r E ALA APR 0 9 1998 • �73 pERMI1' CENTER TITUS' AIR FLOW . 1 0 UP MODEL NO. DTFO ST E: 410 TOTAL CFM: 1100 MIN. CFM: 0 LOCATION AN-i F ACTORY NO: XXXXX rrEM 1 MOTOR D1.01 LAG COIL: E41 -277V KW 6.00 1r THST: DPR. POSmON: DL01 -FMA LAG 303155001015 • } Field Wiring All field wiring must comply with the local codes and with the National Electrical Code (ANSVNFPA 70- 1981). Disconnect switches are optional equipment. Electrical, control, and piping diagrams are shown on the exterior labeling or on a diagram on the inside of the control and high voltage enclosure covers. Unless specified otherwise in the order write -up, all units are wired for a single point electrical connection to the fan and optional electrical heater. All electric Unit Labeling Each unit will have two main labels attached to the casing. The FAN UNIT label (figure 3) lists the Model Number, Supply Voltage requirements, Motor Horsepower, and Overcurrent Protection requirements. The AIR FLOW label (figure 4) lists the Model Number, Unit TITUS® FAN UNIT 14OOEL NO. OTFO CODE 83- XXXXX -A 2 REV:02 MOTOR VOLT 277 PHASE 1 HZ 60 HEAT VOLT 277 PHASE 60 KW 6.0 AMPS 21.66 MOTOR(S) ARE THERMALLY PROTECTED MIL SUPPLY CIRCUIT AMPS 24 AMP MAX. FUSE OR OVERCURAENT PROTECTION 30 AMP MAX OUTLET MR TEMPERATURE 200 F UNIT DESIGNED TO OPERATE AT NO LESS THAN 0211,0 STATIC PRESSURE ZERO CLEARANCE FROM UNIT, CONNECTED DUCT ARMOR PLEM. TO COMBUSTIBLE MATERIAL FIGURE 3 Control Start -up, Operation Detailed information regarding power, ac- cessory and communications connections, start-up and operating procedures for the TITUS TD -1 controller (digital) or pneu- matic and analog controls are available from your local TITUS representative. For specific information on controls by other manufacturers contact that manufacturer's local branch or dealer. Note: Controllers may incorporate specific communication addresses based on Build- " ing Management Systems Architecture, and original engineering drawings. installing the terminal in a different location than noted on unit label may result in excessive start-up labor. heaters if provided by TITUS are balanced by kw per stage. The installing electrician should rotate incoming electric service by phase in order to help balance the building electric load. Caution - Electrical Requirement: 1. Provide a safety disconnect per NEC 424 -19, 20 & 21. 2. Disconnect all incoming power before wiring or servicing unit All disconnect switches on the terminal (if so equipped) Size, Factory Order Number, and Location. The Location (or 'Tag') indicates the engineer's planned location for the unit to be installed. There may be other labels attached to the unit, as options or codes may require. Please read all labels on a typical unit, Fan Flow Adjustment Note: Before starting fan motor, follow steps 1 and 2. 1. Discharge ductwork should be connected. The minimum recommended discharge static pressure is 0.2' wg. Be sure fan packing is removed! 2. All foreign materials should be removed from duct system. Filters should be installed where required. 3. Motor is shipped from factory at full speed setting. Allow motor to run -in at least 15 minutes before adjusting speed. During initial run -in, check ductwork connections for leaks and repair if necessary. (Do not adjust fan speed down if ductwork is not connected). should be In OFF position while making power connections. 3. All field wiring must be in accordance with NEC and local code requirements. Ail units with electric heat should have copper wires for 125% of Nameplate Amperage. 4. Observe wiring diagram and instructions mounted on the unit. 480 V/3 phase units require a 4th (neutral) wire in addition to the full sized ground wire. All units must be grounded as required by NEC 424 -14 and 250. before beginning installation. If you have any questions, please contact the local TITUS Representative, or TITUS direct at (214)699 -1030 for clarification. Have the key points from the Air Flow label available for reference before calling. FIGURE 4 4. Unit is equipped with manual fan speed control, mounted on the bottom of the line voltage motor enclosure or electric heat enclosure. Turning the control counterclockwise will reduce the fan speed; clockwise will increase speed. 5. Set the unit to full heating (maximum induction). Adjust and set remote balancing dampers, if present. Adjust the speed control to deliver the required CFM by measuring air quantity at the room outlets. 6. Proceed to primary air adjustment procedure, detailed in control installation information. If unit is a Series or Constant Volume type, fan should be re- adjusted with primary air at maxim se , o insure that no primary air � the induction port. APB 0 9 1998 pSRMIT CENTRR Maintenance Procedures, Fan and Motor Motor is equipped with permanently lubricated bearings. inspect fan and motor assembly for accumulation of dust and dirt as required by operating environ- ment. Clean as necessary. H fan motor does not run: a. Free rotation of blower wheel Fan packing removed Freight or installation damage b. Check for proper unit power Disconnects should be ON Check optional fusing c. Check for proper control signal P/E switch setting, proper control air 24 vac at fan contactor, coil energized Primary Air Damper MFV and TFC Models: To replace the damper blade and/or shaft assemblies: a. Disconnect power before servicing. Remove control enclosure cover to access actuator. b. Note position of damper shaft, using indicating arrow. Loosen linkage or actuator collar to allow damper to rotate freely. c. Remove bottom access door to expose damper assembly. Rotate damper to fully closed position, exposing Replacement Parts List Description Part Number Multipoint Velocity Sensors Size 6' 311393 -01 Size 8" 311393 -03 Size 10' 311393 -05 Size 12° 311393 -06 Size 14" 311393 -07 Size 16' 311393-08 Primary Damper Assembly, (MFV -TFC), Size 6" Size 8" Size 10" Size 12" Size 14" Size 16" Size 20 x 16 ", Damper Shaft Extension Short Stub All Sizes Long Ext. Sz 6, 14, 16 Long Ext. Sz 8, 10, 12 Shaft Bearing -All Primary Damper Assembly, (FCL, FVL) Sizes 2, 3 Size 4 311713 -01 311713 -03 311713 -05 311713 -06 311713 -07 311713 -08 308359 -01 703003 -01 703003 -02 703003 -03 703249 -01 310723 -01 310724-01 If fan motor runs, excessive noise: a. Clearance problems on blower All components securely attached b. Verify integrity of ductwork Leaks or loose connections Rattling diffusers or balancing dampers c. Maximum CFM too high, or discharge static pressure too low If fan motor runs, insufficient air flow: a. Check for ductwork restrictions Dirty air filters Clogged water coils b. Re- adjust fan speed control c. Discharge static pressure too high rivets holding damper blade to shafts. d. Drill out rivets using 'A' drill, rotate damper to fully open position, and slide damper and/or shaft assemblies out of the duct. e. Fit new damper and/or shaft assem- blies in place, using 1/420 screws with lock nuts to replace rivets. f. Reverse procedure in steps c, b, and a, for assembly. When locking down actuator linkage or collar, position indicating arrow on damper in the same location as before the repair. Primary Damper Assembly, (TFQ) Sizes 2, 3 310341 -02 Sizes 4, 5, 6 310341 -03 Size 7 310341 -04 Induced Air Velocity Sensor TFC, TFQ - 2, 3 TFC, TFQ - 4, 5 TFC, TFQ - 6 TFC -7 TFQ - FCL - 2, 3 FCL -4 Induced Air Filters Model MFV Unit Size Filter Size 2, 3 4, 5 6 22x14 27x17 27x19 Model TFC, TFQ Unit Size Filter Size 2, 3 16x14 4, 5 17x17 6 22x19 7 24X20, 311393 -05 311393 -06 311393 -07 311393 -06 311393 -07 311393 -03 311393 -04 102649 -2214 102649 -2717 102649 -2719 102649 -1614 102649 -1717 102649 -2219 102649.2420 If repair or replacement is required: Motor and fan should be removed as an assembly. Disconnect all power before servicing. Remove the four hex nuts from the mounting Tugs holding the fan assembly to the discharge panel, and lower the assembly. Do not allow assembly to hang from wiring. If removing motor from blower, first loosen the set screw holding the blower wheel to the motor shaft. Remove the three screws holding motor to the fan housing, and slide motor and fan housing apart. Reverse the procedure for assembly. Note: Over tightening motor mounting screws may crush isolation bushings, causing excessive fan noise. TFQ, FVL, and FCL Models: These units use an opposed blade damper assembly that is not repairable. The entire assembly must be replaced. Electric Heat Section Refer to Manual B-EHIM for information on maintenance and troubleshooting of electric heaters. Model FCL Unit Size Filter Size 2, 3 9x9 (2) 4 10x13 (2) 708153 -01 708153 -02 Model FVL w/o Attenuator Unit Size Filter Size 2, 4 10x18 708728 - 02 . Model FVL w /Attenuator Unit Size Filter Size 2, 4 8x10 (2) 708728 -01. Filter Bracket, Universal 711244-01. ' Filter Clip, Wire 102627 -01 Notes: 1. Damper Assy. includes Blade, Blade Seal, Damper Shaft, & Damper Shaft Extension. 2. Damper Assemblies contain complete OBD type Damper with shaft and damper housing. 3. TFC size 7 requires 2 filters per unit. CITY OF V E API? 0 9 1998 PeRMIr CENTER • a F O H I J . T/V (t2imm) 0)s. Clacokal &MIntsler Lan *M g* CanrSalon. 7/e' (22.2mm) OIL OWN* Inn** lot Una Wage Carnevtkn, I'ifl Prnsurs iwndl Patti 0utlon Sudan Use Mlle OUICM Gemini Liquid Una MI)a Dulall Oatit•q I/r (1ama1) N,I•L cram COmwtlolt (Farcondemn/ collwash0Own cny,. A • • d: C_ D. • I& Mr Mann luq MOW Una Mat* uc»d Moe MW 7h' (1111n+n1) OIL HO Mew. t. 1iv 12tAnlm) C1IaM CCnneq owe CO M= 100201041 a tra rc. i•tdi /Inaa. aLL lame Wrs H/WIOak ararsoo• tat )Ella v.Iaip. Law" melon. WINN/value* aannacnion. • 31 MODEL A Width 0 c, .. r , / MMCO24A H he PI, .1 7. s s (37) (240) (519) DM0037A 48 (1218.2) 18 (457.2) 31 (187.4) MODEL A t3 0 c, D r , / MMCO24A 17/Is 11>/w 20A M MCO36A (37) (240) (519) 02/27/1996 05: 15 2062779923 mini- MATE Plus CAPACITIES AND TYPICAL SPECIFICATIONS AIR 0•L Nominal Toni Eva Nom .1 ) • _....,^ .,..M,.�._.. ,.._._...._.._.... _....... ' ' .m i:n I. — MATE . Plus; ,...;•:.:: ..;.: iww. liJ+�..- ...:.�..��w•':w�:'d�t�� ., 44 6:.:+1 41.4..- �.,.'. 4.. L.. vi:r:L.n'r.1.4ti�..ac.'.��:..'.: Centrifugal Fan Condensing Unit (Indoor) al1 . (1014n1 HOLED F011 MOMS mown { TP. 2 EACH ErD). MANOINO iRACrc.T Clearance of 18' (457.2mm) II recomrr>rndad halt and back for proper 24 (eos mm) on fight for ocmponant access and rem Io It!' 401mm1 21Va• OPT,Itn1 OAIIN OIHCNOION MINIMUM OLCAPIANCI SJ• 03Anml 11411 IND POR COMPONINT ACCHBS AND REMOVAL Olmenalons » Inches (mm) Propeller Fan Condensing Unit (Outdoor) Diming one - Inches (mm) 11 Il1' 1WO3H1n1 ovIRAL1. pima/mom NSN• I$Mmnt1 GAMINE? IMINSION C Liquid Une Quick Cornet! (Male Coupling). to ITJ.sews ELECTRICAL DATA >h InW ' (mm) CABINET DIMINOI to VI 42 IA' 1112212,0) TI4 AOID R00 T101114000 POD CINTI • HMO NI � it i t _ orator Section 208/230 Nominal Tone 11,7: LM• COIL F LIT DUCT DON Decoct/ DUCT PLAUDIT t on Pressure If--+R� Switch Regal. l �flflllll�l� �� �I► � • ( ; I IIIIII i ,�i�► , 1111 I ,1 I I�rtt,, II! I LI I1 II PIP . II rl II II,II i I i , CUSTOMER 11111 THPEADED e234'075nm) RODS ROA MODULI SUPPORT OTIRALI. OIMINIION ` 1 PROM CIILM0ITYP. 41. I A 0 NR OUTLET DUCT CONNECTION AIR OUTLET DUCT WARNS/ON ILP N 511140101 [LONBOTTOMOPUNIT. - MINN/uM OLIMANOI 7S• (M oroi FOR Com.ONINT ACCesn AND REMOVAL Eioctr cat and Piping Connections d Ruction Line Quick Connect (Male Ccupi(ngl. llectrICel end Piping Connections PAGE 02/05 A Elecfieai Entrance to High Voltage Connection. D ElactrIcal Emrance tot UN Voltage Canna/CHOP. C17y T ( APR O 13ERMir CS'NrE ILA 8 02/27/1996 05:16 2062779923 ILiebert I jl I ;I I jl I I _ .WI • dam. _ _J Single phase electric service not by Cubes. c........,.. Field supplied t udt disconnect switch. Una Voltage electric power supply entrance. Single phase electric service not by Hebert. Electric service connection. (Optional) condensate Pump electric power supply entrance. Factory wired to components on electric panel. Entrance for tow voltage control connections, Entrance for low voltage connections, Factory wired to components on electric panel. Mom Unit shutdown /startup. Replace sconce limper between TB3•1 and 783.2 with a normally closed nort•powered switch, having a minimum 75 VA, 24VAC rating. Use field supplied class I wiring. Installation, Operation and Maintenance Manual (1/92) • Factory supplied field wired 12 conductor cable. to remote control panel. Field supplied 24V (NEC class 2 wiring for Air cooled units, NEC class I wiring for Water and Glycol cooled units) to condensing module. Earth ground connection. Connection / terminal for field supplied earls grounding wire. Commen Alarm Connection, Terminals are non powered for connection of tieed supplied 24 V NEC class 2 wiring. �rtt M� ra Tit Rcrw Figur* R, Evaporator Unit Electrical Connections (2 and 3 ton) - 18— RON GREENE PAGE 03/05 • '" " Computer Support Systems supplied 24V (NEC Baas 2 wiring for Remote Air cooled units, ham terminals 1 & 2 In Inc Fan /Coll module to terminals I & 2 in the condensing module. Remote contra panel concoction, Factory supplied, field wired 12 conductor cable. mini-MATE Plus R cITV op. V ec, APR 0 9 1998 PERMIT CENTER - mip.17.M•ATE'Piu.e { 02/27/1996 05:16 2062779923 6 Ducted Application of Evaporator Unft sM• N MU 01 Ei� w• 1M1NLs1/ ppVV� MLL m1 4 . tie OIMSNerONI TPREADED /' 1t✓• ROD �/ =NTI • i2Slmro) 10' (4B7mm) A 7/S' (22.2mm) Dar Electrical Entrance for HO Whip Power Supply. tt (2Nmml r IS' (lb)mm) INV I lErem) (OPTIONAL) FILTER BOX tepllonal) 7/5' (222mm) DES. Electrical Entrance br Coedsnaals hump Oonnsaton. RIMOYASLE PANEL ON SIDE OF PLENUM. MINIMUM 0L1ARANOE 0a• Move) FOR FILTER ACCESS ANC REMOVAL. 1 LE' damm) CUSTOMER SUPPLIED TNRIADED Robs POP MODULI SUPPORT FROM caILINO (Tye. •L 1 tote 1 24• worm CAGNI:T DIMENSION C Seaton Urn Cern* Oulok Comer LOeattoo. OOVIR PLATE IWPPUID WITH PLENUM, HANGWO BRACKET CABINET TIE' OUTLINE (4Nlam) GRADED AMA 1NOICATIO A RECOMMENbID CLEARANCE OP 2e• (7E1mm) DINMARGE SIDES OF KIND a a4• CASINET DIMINSION 20111' 4 ••• — • pltmro) THRIADID R CINTIns RON GREENE RIMOVAIL1 ACCESS 1 11P• PANELS RIMS (tome HOLEE FOR MODULE PIGGING rip. 7 GASH its* E ectrical and Piping Connections D Uqu$d Lie P mI(s oulsk Ooerled. .E (OgIPa17)1 /4 (0.4mm) Nt1 remote IiW VKd er Supph' OoanecKorl Nan - Ducted Application of Evaporator Unit • .. .. . ... t.' a.:. L:« •-. ww'.1/;.t4 :LI:1i»::.Jd1:;.'.'l.: ..:f .. • . N• OEISANN AIR INLET TMROUOM GRILL IN MINTER OF PLEN GANNET DIMENSION! 14(41 AS AIOVE. 14' 0• IESErNI( llitmm)' (o T AIR (oNA14 Qi1OH.AROE DUST FIANCE SUPPLIED WMEN (OPTIONAL) FILTEn sox in ORDERED. u•I107mrry ) SMADID ARG INOIOATES A RECOMMENbCC OLEARANCI OF IV (701mrrl EE PROVIDED FOR ACME A140 PILT1R REMOVAL FOR RECOMMENDED MINIMUM CLSAPA.NOE REFER TO (NETALLAMION MAIIUAL NOES 1.114I7 Is 1PACIID EVENLY IN • RIPIIINCI TO THRIADID ROD 01N7144. 3/4' (1Smm) N.RL Female CwlosnsEI DWI COnnsdtan. Ltllln M trapped Internally and must na • Nwoed Wks at tDS 1{sd1le a 1/4' (ltEmm) DIL Wilms let Low Yonape Connsabn Oonoerutng unl 1Wls� LEENUN al• (31Omrf) PAGE 04/05 :1i 12/i' (95min) D1s Ira for tow Wade COnnactonto Remote Control Oc s. 1 • /Mr Cooled Systems Altl OF T uKWIL. APR 0 91998 PeRMIT cameo vaporetto so on 20A x Nominal Tone 3 886 (1604,8) MME024E \ MME036E COOLING ONLY 800 (1380) FLA 4 WSA _ _ 'r 2.6 2.6 3.3 3.3 OPD ''` 16 WITH REHEAT 0.3 (75) FLA Evaporator Coll - Copper Tube/Aluminum 21.4 27.6 WSA 2,6 (025 28.8 , 34.5 OPD Max. Faco Velocity •m m/s 30 40 WITH REHEAT AND HUMIDIFIER FLA _ 26,9 33.1 WSA 32.3 I 40.0 OPP 40 40 -- - vaporator Siouan 277y, 14', 60 Hs •• • ING ONLY Suction Lino - in. Humidifier 9u • • I - FPT 2.9 - WSA V/4 2.9 2.9 OPD . ,_15 , , ., 16 WITH REHEAT Sonata FLA ,, 6.5 24,0 WSA - 1 30.0 OPD _ 30 30 WITH RE. AND HUMIDIFIER F .. 9 5 A 28.6 ,. a - D 30 40 -an bate - Direst Drive . , ''. 5 High Spored dm (cmh) 886 (1604,8) '50 r ) Low Speed dm (cmh) 800 (1380) 96• - 0.5) Fan Motor Hp (1 1 /a 373 1 1t � , 3 External Preatsure- In.. H 0.3 (75) 0.3 (76 Evaporator Coll - Copper Tube/Aluminum Fin Face Area k= (ms) z.e (0.25) 2,6 (025 Rows of Coil _ 2 a Max. Faco Velocity •m m/s 326 1,85 4 : ,4 Reheat Data - Electric A_ Capacity- Btu /h (kW)* Includes tan motor 18400 (4.8) /100 (8. Humidifier Data - Steam Ganeratin • T • Capacity - Ibe /hr(kg /h)' 2.6 (1,1) 1111111111Z111111111111113LJ II Niair Connection Sizes U • uld Line - In. Suction Lino - in. Humidifier 9u • • I - FPT 1 /4 , Evaporator Drain - FPT - V/4 • Alr Cools Condene ng n Options Outdoor Pr . • liar Condenser Co AIR •'1 D Nominal Tons DMCO27A >► ' 037A 2 3 Evaporator Election MML0245 5086 Net Capacity Data - Btulh (kW) N h Fan Speed 80°F (27 °C) D8 50% RH Total 23900 .0 35000 1.2102001111 zl a* Sonslbta 10500 5. 22000 6.411, 75'F (24 °C) DB 50% RH otai Se 1• 111114•1101.J1111= 20900 (8,1) 1a. ' - 0 (0.0) 72 °F (222•C) DB 60% RH Total SansIble 18200 (6,3 100 (7.6) Net Capacity Data -• Stu/h (kW) Low Fan !peed 80 °F (27•C) DB 60% RH Total 23500 6.9 «600 0.� Sent(bl4 18400 5.4 • • r 75'F (24'C) DB 50% RH To 21700 6.4;m Sensible 17600 (5,2 72'F (222'C) 05 60% RH. Total 20700 5.1 00 Sonata 17200 (5.0) 260Q (0 Alr Cools Condene ng n Options Outdoor Pr . • liar Condenser Co I end Fan ( -30' to 95' Amb•) Condensen • Module DMCO27A >► ' 037A MIGMEMLEMIIIIIIIIIIMi 5.0 0.46 *7.7 0.72 II • • 4, 2 . W 1 /5 150 11 Indoor Centrifugal Condenser Co I and fan 88• ME MM • Condensen • Module MMCO24A INETZIM:=1 omhl 1000 1700 EL'afIraik tT • • 47 Face Area ft" m 4.6 0.43 Rowe of Coll 2 1iarai3all/1 0,8 (125) W ■U 7 0.5 (125) ' Motor H • ESP in H2O (Pa) ntrlfugel Fan Condon. ng t n t '•,• r'• , . T • • • ii • Unit 208 /230v 60 Hz 024A t. MMCO L •■ 143 ML7 1 • • 4, FLA 12.4 - N u I OPD `rte" �tli•In__1 25 th BuckTrenaform to ' • 1 •, 60 Hz LOAD x,1 �"•- MMCO24A MMCO3 • - .;,,, 11.2 L� 'a'1. 11117T - 1 11111111M■ MI p 20 30 - o • I • F - , o i"•. , • ii • Unit 208 /230v 60 Hz • DM••••7A DMCO3 DMCO37A 1 220 Ibe (19.8 kg) 14' • • 4, FLA 12.4 17.• 12.3 WSA .9 5.0 OPD 25 I 36 Evaporator emotion MME094E ' 190 Ibe (862 kg) MME030E • 195 Ibe ($6.5 Ito) Propeller Pan Condenses Unit DM61027A 180 lb; $1 6 kg) DMCO37A 1 220 Ibe (19.8 kg) CanlriluaalEmn Condone ng Unit - , MMCO24A a 1113.4 kg) MIA'•' _ 2211Er • 02/27/1996 05:16 2062779923 u• / 1• • pl r% I'4 I I Y N a CAPACITIES AND TYPICAL SPECIFICATIONS 'Rated capacity 0 230 volts RON GREENE ELECTRICAL DATA UNIT WEIGHTS PAGE 05/05 Alr Cooled Systems 2 and 3 Tons c11 VED Op T�KINI APR 0 91998 PE R MIT CENTER _ I I t_ --I I I L n y0 I T . ' 1 I "roil I_ -.._. .u , ��— LOUDER LEVEL FLOOR PLAN' # NVAC SCAL e" •. 1,_0 tuununHnluhmi 250, r ,, IO I.� N SUpF NOTES: iO 24 "x 24 "R4G (0R 24 "x1TRAG) FOR LOCAL RETUR14 AIR TO VAV. BOX GRILLE 19. EXIST, SHALL BE RELOCATED TO LOCATION INDICATED. EXTEND/PROVIDE NEU 16 DUCT FROM GRILLE TO EXIST'G VAV BOX SERVING THIS AREA PROVIDE VOL DMPR • VAV RA PLETU 2O 24, 24 "R4G (OR 24"x11"RW) FOR GENERAL RA TO CENTRAL WIT. GRILLE IS EXIST'G SHALL BE RELOCATED TO LOCATION INDICATED. EXTEND /PROVIDE NEW 16"e DUCT FRCM GRILLE TO EXISTG CENTRAL RA DUCT. FRO, DE VOL DMFR • MAN TIRL6K 0 RELOCATED T -STAT. VERIFY ACTUAL LOCATION ON SITE w/CPI ENG PRIOR TO RCW14 -R1 0 RELOCATE EXIST'. FPVAVNAV BOX AS INDICATED. MEND EXIST. SUPPLY AIR DUCT AS RECD. 0 NEW FAN FPUERED VAV (FPVAV) OR COOLING ONLY (VAV) BOX PROVIDE CONECTICN TO EXIST'. FRIMARY SUPPLY AIR DUCT AS REQD, SIZE PER BOX INLET. PROVIDE •/SUPPLY U RETURN AIR PLEN1.6. AS INDICATED. SIZE BOX AS INDICATED ON SCHEDULE BELOW 0 REMOVE EXISTPY. EQUIPMENT 1 RETURN TO DUPER REMOVE DOUNSTREAM DUCT 1 .RD's. 0 RETURN AIR TRANSFER ASSEMBLY •/CAD SIZE INDICATED. FOR 2e. 11 GRILLES, INTERCONNECTING DUCT SHALL BE 12"U. FOR 24" z 24" GRILLES PROVIDE 16 "d DUCT. 0 - RANGE CD NECK SIZE OUCT/SPN -N PIE 101 - 200 8" z B" 8 201 -350. 10" x IZ" 10"0 351 - 500 n" x 12" ITT 681 501 - 680 14° x K" 144 EN -850 16' x 16' Id'o 881 -1115 E "xUj" 164 VAV SCHEDULE I 48,3 7AvV4wifELEC EC DUCT COI_ 4 '''''2 :0 2,•170 DUCT COI_ ' :03 150 2 ASZ"i 04 2 000 4&®.3 vAV w/ELEC DUCT CO _ a 105 ., I6Z .06 1200 '1'1200 206/1 VAV w/ELEC DUCT COT_ `m iZb w 70 °_ e00 2T1/'.. vAV w/ELEC DUCT CO._ 11'10 60C 2 ��'� VAV w/ELEC DUCT CD''._ I II' I2 400 VAV w/ELEC DUCT CO _ IU TITTP,9FV 500 4 20/I NEW FPVAV ID TITUSrFi'FV 000 4 211/1 NEW FWAV 114 TITUSrPMFV P00 4 211A'. NEW FPVAV 15 rIT1SRIFV 000 4 211n' NEW FPVAV COMPUTER ROOM AIR CONDITIONITUP WIT (SPLIT. SYSTEM) w/CCNDENSRY WIT ON ROOF. 'LEIBERT MINI -MATE PLUS ¶ME024E, 2 TON NOMINAL. CAPACITY, 800 CR1 . 125" ESP, MOOR UNIT PCT. • 1905, OUTDOOR WIT LLGi • 18005, 208/230v -I• ELECTRICAL WIT BANISHED BT PIKER VERIFY LOCATION. OF WITS ON -SITE . w /EXIST. CONDITIONS. COORDINATE RCIUTPUU OF REFER PIPPNG w/EXISTRO TENANTS AND'OINER'S REP. e CO1FUTER ROOM OR CONDITIONING WIT (SPLIT SYSTEM) w /CONDENSING WIT ON ROOF. 2 LEIPURT MPII -MATE PLUS *ME024E, 2 TON NOMINAL CAPACITY, 800 CR 1 •..125 ESP, INDOOR WIT MT • 1905. OUTDOOR WIT MT • 100.5, 208Q30v -Ie ELECTRICAL WIT PURNISHED BY CANER VERFY LOCATION OF WITS ON -SITE. •/EXIST. CONDITIONS. COORDINATE ROUTING OF REFER PIPPG w/EXISTPXs TENANTS AND O'UNER'S REP. DIFFUSER SCHEDULE 5TRANDER BLVD SITE , ;FILE. COPY _i.��oriz9 �Up v. Ill WASHICTCN STATE PATROL PERMIT DATE: ASBUILT DATE: 9/30/9T E:1 11 __ I I '� - , ! i — r "III / „ � 1= SEPARATE PERMIT FEQUIRED FOR: 0 MECHANICAL 3 ELECTRICAL PLUMBING -j US PIPING CITY OF TUKWILA E GILDING DIVISION A5 NOTED 9/30/91 . Corporate Square Building "4 Southcenter Corporate Square Andover park West Tukwila, WA HVAC Floor Plans MINCER BLVD VICINITY MAP e NTS. 4/6/S5 'Metro One Tenant Improvement ST G5.'^.... IJdsKnoton. State Pd.tG AOOeo Lace, =/ UTMOST D A T E , ' R. E V 15 C, N 5 COMFORT FORo ` � 6617 S. 193rd Place, Suite KENT, NA 98032 'Q ; (425)251 -9840 (425)251-9871 (Fax)