Loading...
HomeMy WebLinkAboutPermit M98-0091 - PRINT MANAGEMENTf\+ c`(\WVIOS DD City of Tukwila ( < (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0091 Type: B -MECH Category: NRES Address: 6700 S GLACIER ST Location: Parcel #: 788890 -0080 Contractor License No: LODESRC174K0 TENANT PRINT MANAGEMENT 6700 S GLACIER ST, TUKWILA WA 98188 OWNER CASCADE DEVELOPMENT CORP 5301 2ND AVE S, SEATTLE WA 98108 CONTACT ROD CHRISTIANSEN 6605 200 ST SW, LYNNWOOD WA 98036 CONTRACTOR LODESTAR CO 6605 200 SW, LYNNWOOD, WA 98036 ************** k***************************** * * ** * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: UMC Edition: 1994 Valuation: 24,535.00 Total Permit Fee: 81.88 ******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** MECHANICAL PERMIT REPLACE (1) EA. 8 -1/2 TON GAS /PAC AND (1) EA. 5 TON GAS /PAC WITH NEW - RECONNECT TO EXISTING DUCTWORK. Status: ISSUED Issued: 05/27/1998 Expires: 11/23/1998 Phone: 425 - 670 -1968 Phone: 206 670 -1968 6c 5-1.13 LZ Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this bui lOigg 'j` rmi Signature:__ �; Date: Vi2Vig Print Name:___ W_ :fa 'jPkS Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Project Name/Tenant: I'R1UT MAu LM EtiT Value of Construction: 7. , 71-1 .s3,' Site Address: G oc City State /Zip: S • G LA — C �S ' , 74D r . L,L_ a Tax Parcei'Number: `r� -�P2� o O Phone: Property Owner: ?TP Street Address: City /State /Zip: 0 Water City State /Zip: Fax #: Contact Person: Pc en .,1 771/VJ` P Lob ES Cod Phone: • ( ex,- 1 C I . 6$3 Street Address: ` � (, 7 ST. S' City State /Zip: L N►,1'vlcrdn ' ec+.•, Fax #: - �7 Contractor: Cc7 , Phone•• ., ( G 70 -- ) `ll; ; �°� x.31 !VF Street Address: City State /Zip: O 5 '3-00 ST, Stn/ . is u \tux)) ' Fax #: . , L a T f b 7 Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done: ` LAC1 ( 0 En• - f 2 .- 7 0 N C f'S rAC 7` i 611. �` - j b 6 f S PAc. WITI -f IU&V) - Co ?JU R ice' —'"/_ ST XYG U'"T L Will there be storage of flammable /combustible hazardous material in the building? Cl yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes ❑ Demolition ❑ Fence CI Parking Lots CI Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting ❑ Bulkhead /Docks Cl Commercial Reroof -- Mechanical CI Manufactured Housing - Replacement only ii �� I Temporary Pedestrian Protection /Exit Systems MONTHLY SERVICE BILLINGS TO: Name: I Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF ( '!KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 STAFF USE ONLY Fe• Project Number: Ami Permit Number: MID OO' Miscellaneous Permit Application WATER METER DEPOSIT /REFUND BILLING: Name: Address: MISCPMT.DOC 7/11/96 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST. FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping El Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing El Landscape Irrigation ❑ Sanitary Side Sewer #: El Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use El Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling Data application accepted: Date application expires: Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Applicat n taken by: (Initials) I BUILDING OWN R OR UT ORIZED AGENT: • PERMIT REVIEW Submit checklist . No: M - CI Signature: / { T7,01 ('p 41,i4I e t. Commercial Tenant Improvement Permit I Date: S 5 -7iig Bulkhead/Dock Print name: • Commercial Reroof 7,11. - j �� c Let h7A 14 be, I F 775- ) '6I Address: • ,� Submit checklist No: M - 9 - -H r - , Land Altering/Grading /Preloads City /Stte / i : r , rl SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist . No: M - CI Antennas /Satellite Dishes Submit checklist No: M - fJ Awnings /Canopies - No signage Commercial Tenant Improvement Permit 0 Bulkhead/Dock Submit checklist . . No: M -10 0 Commercial Reroof Submit checklist No: M -6 ri ' Demolition Submit checklist No: M -3, M -3a El Fences - Over 6 feet in Height Submit checklist No: M - 9 El Land Altering/Grading /Preloads Submit checklist No: M - 2 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 a Mechanical (Residential & Commercial) Submit checklist No.. M - 8, Residential only - H-6, H -16 D Miscellaneous Public Works Permits Submit checklist No: H - 9 0 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist: No: M - 5 El ' Moving Oversized Load /Hauling Submit checklist . No: M -5 0 Parking Lots Submit checklist No: M -4 El Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 0 Retaining Walls - Over 4 feet in height Submit checklist No: M - 0 Temporary Facilities Submit checklist No: M -7 • In Temporary Pedestrian Protection/Exit Systems Submit checklist No: M - 4 0 Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS P - IT APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: ➢ 4ALL DFZAWINGit S'I-I/CLL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) El Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building. Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,,or, contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 Address: 6700 S GLACIER ST Suite: Tenant: PRINT MANAGEMENT :Type: B-MECH Parcel #: 738890-0030 **Agt Permit Conditions: I No chanoes will be made to the plans unless approved bv the Architect or Engineer and the_Tukw,i1a Division. 2. All permits. inspectione6OrdSinA: Plans shall be available at the iob''sjte t6 't any con- . ,struction. Thesed6Cumentsal-e to he maintaned,,and avail- able until finaI- is gkantki';',..:,:::,-, 3. All construOjan to Yin abONyed plans and of the ,OniforM BuTlding,,Code!AI:994 Editl00/:asamended Uniform -Code:J1994,Edj:tjon). and WashAngton State EnergyHCode (1994 Edition). 4. ValiditY/of Per The Jssuancle a perm'i'torapprokajof plans',I,-specifications. and;Comoutations sha11 con-;::::, struedto.be a permit 'for :'or an a'Oproval of any viOl4007(.. of iny of the provisiO of the - building code or,ol,a0_ other?ordihance of the.iurisdiction:: No permit 0..esui*Y6'9 tO giVeauthority to violate orhcancel'the provisionsof„ code :shall bevaltd'..-. ■: . . ,‘, , .L ..", C' MANUFACTURERS' INSTALLATION INTROCTIpNS-REPUIRED OW SITE ' I ( F OR ; THE, BUILDING IN$F REVIEW: .. ‘, :,.4 4 , :.; " . ■ t , • . , ; , 1 , . • , 1 ; , : . , ,); t,' 1, • ■ . .• \ • , , . • .• , •.% 4 ■ i '' S • ' CITY OF *TUKWILA Permit No: M93-0091 Status; ISSUED • Applied: 05/05/1993 Issued: 05(27/1998 ACTIVITY NUMBER: M98 -0091 DATE: 5 -5 -98 PROJECT NAME: PRINT MANAGEMENT DEPARTMENT: BtJiing Division Fire Prevention Ei Pu61ic Works 410 n Structural 6.11-q) ❑ DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 5 -7 -98 Complete Incomplete ❑ Not Applicable ❑ Comments: TUES /THURS ROUTING: Routed by Staff El \PR•ROUTE.DOC 1/98 PLA�N�EVIE Please Route Approved El Approved with Conditions (if routed by staff, make copy to master file and enter into Sierra) Planning Division Permit Coordinator No further Review Required ❑ REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 5 -21 -98 Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: ID:LANIERF X3800 Department of Labor & Industries Contractor Registration Section PO Box 44450 Olympia WA 98504-4450 TEMPOiRA R Y (' -ry /: 1 ✓ ,&• v//1 X' - e1isieieIhama Rojiitradon numbfc Registraticm expires Contractor: Your Certificate of Registration will be sent from the Olympia office and should be received within 2 to 3 weeks. Please keep this record until you receive your Certificate of Registration. 05/25 '98 08:19 F625 -036-000 registration verification 2.95 (Receipt expires FAX REGISTRATION VERIFICATION roan - Th Olympia Headquarters (360) 902 -5226 FAX (360) 902 -5225 PAGE 1 COMMENTS: Nt . • tinssPvn�8r4 's is mextsv4"v reit - 1 r‘Sni- '.t.,h1 ar4 . (t- , i M tn.: I 9 tectv,.t, - Acuss `to 0-' c -sue,, Uec, wuaz5 Cotz. —. t It SQe-r.n"-t,NoJ 2) + C;h2 P,Pig, IS rA IT (4E ..ulflt'S A. eeflAil r i . 3) .Smatc. . S ttv., ,O,ivi irk- 1 S (456 to....e), ?ifi 3 w tis P.X' Gift.), N 11-1-1r'] k 1 j i4 lAs Ar'1 { 1PE n A.C. . . 6:q1— Del n<M'Vt. fi : gEN c � . J 6 ttE Dom""_ c:.,.' t - rt..- 14-A v, C, vn ,zr it_.. 12..'..o-k.• ‘ ►t � . Pr ect: 1�IC r /l)T 1 p nrk) 7" Type of inspection: F //VA L Address: 627lDv S. (,l iirlc,,=T Date called: (r Special instructions: Date wanted: a.m.. (n' ? - ,. na- Requester: () Phone No.: �c, - G, -7U - /,a INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 l Approved per applicable codes. INSPECTION RE " RD Retain a copy with .;rmit PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Inspector: f Date: (' $42.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: '** »+�*�*++�+**��* *�+^ �� *� �*� * ^+++� * + +^*+a*»*+**/h^*+«h«°«**OcAhA * + [RAN8MITNumber: R9?0077O Amount: 81.88 05/27/98 14:57 pavment Nethod: CHECK Notation: LODESTAR .CO. • Ini,t:,KJP Yeow1t No: M90~0091 Tyne: O_MECN MECHANICAL PERMIT" parcgl'No: 78889O-0080. 8itoAddrousx 6700 S GLACIER ST' Total Feps: Thiv Payment G1O8 Total ALL Pmts: 81.88 ' - ' ' .' U|ncox • .0V ^+ 4 ***4^+**a«a++ /^A*+*^+*+a++*+****a**oa*** ^lkk++«a**,****■^++^ Account 000/S45.83O -- 000/022°100 Deqcriotinn PLAN CHECK - NONUE8 MECHANICAL - NDNRES Amount 1638 . 65.50 �1 ..N #i 't •: .::...: :.•.::..:: ::x.;. : :::..... ....... }i } :i::.: :,. ...::{ : : . ^ � . t,� � <� < <F . .:. }'i:v .• :r... • r:. vi :� {: .,:::.•:•:::•:::::•:•:::,:,:..:::::::,:. f. • } } f r: Balance Due: $ 81,88 Need Current Contractor Registration Card: Need to Enter Contractor Information in Sierra: Yes Yes )(No X N 19•1“, &.“..#i d 9.6 1 VA)11 Of,5C3-101t..Cr ' tho Plan Check approvn!, aro t: CFA-014360M 2 • • ^ _ ..3 not author all Violation c; a::: code oi 0111611.6-11111110 brZc:in-ti-actOrs 001 CF[Y OF TUKWILA APPROVED MAY 1 4 1990 'AS Ln LEifNe—bi Ns0-1 pagGe g l oc. CSkl Cr &lu vox ■I vesi oett° I I4L..1 ii l•-/ I • *III ,1144, 14 1...11.411L. I I 1, • .a. • a. I I•ti II ills II Is I a pi,v05 cx, v olitic.c4 • • 4.1 1.41 4. 44 IV .4. Airy s oe IcTCP 6c,ib4iRc. 4.411H OJc.i • - to CSIke CITY OF TUKWILA APPROVED_ soo 44-AY I 't 1938 l'of1■1 s 19W AS NOTED V\N1 t ,rt BUILDING DIVISIQN 9sol Ow' SINGLE PACKAGE AIR - COOLED CONVERTIBLE SERIES AIR CONDITIONERS DCHB 036, 048, 060 & DAHB 072 DGUC 036, 048, 060 & DAUC 072 3, 4 AND 5 NOMINAL TONS (10 SEER) 6 NOMINAL TONS (9 EER) MODEL DUC CiIY OF TUKWITA APPROVED MAY 1 it 1998 AS NOTED BUILDING' DIVISIO l M's bbfI DESCRIPTION The DHB and DUC units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for residential, light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self - contained and assembled on rigid full perimeter base rails with fork lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to provide for a quick and easy field installation. The units are available in cooling only, and cooling with gas heat. Electric heaters are available as field - installed accessories. The cabinet is constructed of galvanized steel, painted with long lasting, durable, and aesthetically pleasing power paint. Paint finish meets 750 hour salt spray tests per ASTM -B117 standards. All models include a 5 -year limited warranty on compressors and electric heating elements, a 10 -year limited warranty on gas -fired heat exchangers and a 1 -year limited warranty on all replacement parts. FEATURES 530.1 8•TG 1 L(295) COMMON FOOTPRINT /COMMON CABINET - All model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. He can even decide between gas or electric heat after the curb has been set.h HIGH EFFICIENCY - All units have a high cooling efficiency, and gas / electric models have a minimum AFUE of 80 %. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / bottom return is desired, you simply remove the two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory Economizers may be used on either bottom and side duct applications with no modifications required. FACTORY - INSTALLED OPTION - Adjustable belt -drive blower is available on 5 ton, single and 3 -phase models, and 6 ton, 3 -phase models from the factory to provide maximum air flow flexibility. RELD - INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided In the internal •. ; , � �� conned the elements to the control box • Yd. MAY 0 5 1998 PERMIT CENTER MODEL ARI RATINGS NOMINAL ELECTRIC HEAT CAPACITY (KW) COOLING CAPACITY 80 / 67 -95 °F SOUND (IATING (bels) MBH SEER EER 240V 480V 600V DHB036 40 10.10 9.30 8.6 5, 7, 10, 15 &20 7, 10, 15 &20 10, 15 &20 DHB048 48 10.35 9.45 8.6 5 7, 10, 15 &20 7, 10, 15 &20 10, 15 &20 DHB060 59 10.15 9.40 8.6 5, 7, 10, 15,20 &30 7, 10, 15 20 &30 10, 15, 20 &30 OHB072 72 - 9.00 8.4 5, 7, 10, 15,20 &30 7, 10, 15, 20 &30 10, 15, 20 &30 MODEL ARI RATINGS GAS HEAT CAPACITY COOLING CAPACITY 80 / 67 -95 °F SOUND RATING2 (bets) INPUT (MBH) OUTPUT (MBH) AFUE ( /o) S.S.E. ( / °) S.E. (%) TEMP. RISE ( °F) GAS LINE SIZE (In. OD) MBH SEER EER DUCO36N050 40 10.10 9.30 8,6 50 40 80.9 81.6 75.9 15 -45 1/2 DUCO36N100 40 10.10 9.30 8.6 100 79 80,5 80.8 73.6 40 -70 1/2 DUC048N075 48 10.35 9.45 8,6 75 59 80.9 81.6 77.3 25 -55 1/2 DUC048N125 48 10.35 9.45 8.6 125 99 80.3 80.6 77.9 45 -75 - 1/2 DUC060N100 59 10.15 9.40 8.6 100 79 80.5 80.8 73.6 25 -55 1/2 DUC060N125 59 10.15 9,40 8.6 125 99 80.3 80.6 77.9 35 -65 1/2 DUC072N100 72 - 9.00 8.4 100 79 80.5 80.8 73,6 25 -55 1/2 DUC072N125 72 - 9,00 8,4 125 99 80,3 80.6 77.9 35 -65 1/2 ODELS MODELS DHB/DUC 036 046 060 072 EVAPORATOR OW R BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. In.) FAN MOTOR HP (DIRECT-DRIVE) FAN MOTOR HP (BELT D 12 x 10 1/2 - 12 x 10 3/4 - 12 x 10 1 1.5 12 x 11 1 1,5 EVAPORATOR COIL ROWS DEEP FINS PER INCH FACE AREA (Sq.. Ft.) 3 13 3.6 3 13 4.3 3 13 5.1 4 13 5,1 CONDENSER FAN MOTOR HP ' (in,) 2 /2 2 2 1/2 2 2 NOM, CFM TOTAL 4.500 4.200 4.500 4.500 CONDENSER FINS PER INCH 16 19 22 16 COIL FACE AREA (Sq Ft) 17.1 17.1 17.1 16.7 AIR QUANTITY PER UNIT 14" X 20" X 1") 2 2 2 2 FILTERS QUANTITY PER UNIT (14" X 25" X 1 ") 1 1 1 1 (SEE NOTE) TOTAL FACE AREA (sq. ft.) 6.3 6.3 6.3 6.3 OHARC4F RFFRICIFRANT 22 IIbi /n71 R/0 6/6 7/4 16/3 RATINGS CAPACITY RATINGS - Cooling / Electric Heatin CAPACITY RATINGS - Cooling / Gas Heating I Ratings are In accordance with ARI Standard 210. 2 Sound ratings are In accordance with ARI Standard 270. 3 Heaters are available as accessories - all with single point power supply. SEER • Seasonal Energy Efficiency Ratio • the total coding output in BTU's during a normal annual usage period for cooling divided by the total electric power Input In watt-hours during the same period. EER = Energy Efficiency Ratio - the cooling capacity In Btu's per hour (Btuh) divided by the power Input In watts at any given set of rating conditions, expressed In BTUH per watt (BTUH/watt), AFUE • Annual Fuel Utilization Efficiency - determined In accordance with DOE test procedure. S.S.E.. Steady State Efficiency. (Percent Output). S.E. • California Seasonal Efficiency • determined in accordance with test procedures as specified by the Stole of California Energy Commission. Furnaces are available with a low NOx accessory. . Not ARI Usted. PHYSICAL DATA - BASIC UNITS NOTE: Filter racks are adapted for 1' or 2' thick filters. COMPONENT WEIGHTS COMPONENT DHB (Cooling only) 50 Mbh 605 75 Mbh 100 Mbh 125 Mbh 615 0 3 TON 4 TON 5 TON 6 TON 585 645 655 610 670 680 735 Basic Unit Options and Accessories NOTE: Weights are given In pounds. Unitary Products Group DUC (Gas / Electric) Belt -Drive Blower Economizer Motorized Outdoor Air D mper Electric Heat (Nominal KW) (DHB only) Roof Mounting Curb Belief / Fixed Air Damper 5 -7 KW 20 - 30 KW MODELS 50 48 18 28 92 HB & DUC 5 530.18-TG1 670 725 5 19 RECEIVED CITY OP TUKWILA MAY 0 5 1998 3 PERMIT CENTER DESCRIPTION RESISTANCE, IWG CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Economizer/Motorized Damper 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 Electric Heaters) 5 - 15 KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20 - 30 KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 Bottom Duct Connections 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 0.19 0.22 _Cooling Onlv 0.08 1 0.10 , 0.12 0.14. 0.16 0.18. 0.20 0.23 0.26 0.29 0.32 MODEL BLOWER RANGE (RPM) MOTOR' ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT HP RPM FRAME SIZE SERVICE FACTOR PITCH DIA. BORE (In.) PITCH DIA. n BORE (In.) PITCH LENGTH I DESIG- NATION DHB /DUC 060 850. 1220 1 -1/2 1725 87 2.3 4.4 30.7 , 45 45 c A36 DH: / DU 172 900.12 0 1 -1 17 5 110 54 2.3 1.4 4.4 2.2 24.3 12.5 35 15 35 15 a �i - • ELECTRICAL DATA - Basic Units with Direct -Drive MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEA NOTE 1) COMPRESSOR COND. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA TOTAL UNIT AMPACITY, AMPS MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. WIRE SIZE, AWG (SEE NOTE 31 MIN. MAX. RLA LRA 208/230 -1-60 187 253 19.2 87 2.3 4.4 30.7 , 45 45 8 036 208/230 -3 -60 460 -3.60 187 414 253 504 14.1 7.1 110 54 2.3 1.4 4.4 2.2 24.3 12.5 35 15 35 15 10 14 575-3-60 575 -3 -60 518 630 5.8 44 1.4 2.2 10.9 15 - 14 187 208/230-1-60 187 253 23.1 105 2.3 5.0 36.2 50 50 8 048 208/230-3-60 460 -3-60 187 414 253 504 14.7 7.1 130 64 2.3 1.4 5.0 2.2 25.7 12.5 40 15 40 15 10 14 518 575-3-60 518 630 6.4 52 1.4 2.2 11.6 15 - 14 208/230 -1-60 187 253 28.2 135 2.3 6,6 44.2 70 70 6 060 208/230 -3 -60 460 -3-60 187 414 253 504 16.7 9.6 150 73 2.3 1.4 6.6 3.3 29.8 16.7 45 25 45 25 10 10 575-3-60 518 630 8.3 59 1.4 3.3 15.1 20 - 12 208/230 -3-60 187 253 20.7 156 2.3 6.8 35.0 50 50 8 072 460 -3 -60 414 504 10.0 70 1.4 3.6 17.5 25 25 10 575-3-60 518 630 8,2 54 1,4 3.6 15.3 20 - 12 ELECTRICAL DATA - Basic Units with Belt -Drive MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) COMPRESSOR CD. MOTOR, FLA SUPPLY AIR HOOTER FLA TOTAL AMPACITY A MAX. FUSE SIZE, (S EE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. WIRE SIZE, AWG (SEE NOTE 3► MIN. MAX. RLA LRA 208/230 -1 -60 187 253 28.2 135 C9 C7 '4.'4: N CV ter' 8.6 48.2 70 70 8 060 208/230-3-60 460 -3 -60 187 414 253 504 16.7 9.6 150 73 6.0 3.0 29.2 16.4 45 25 45 25 10 10 575-3-60 518 630 8.3 59 2.4 14.2 20 - 12 208/230 -3-60 187 253 20.7 156 2,3 7.3 35.5 50 50 8 072 460 -3-60 414 504 10.0 70 1.4 3.7 17.6 25 25 10 _ 575-3-60 518 630 8.2 54 1,4 2.8 14.5 20 - 12 ' 530.18 -TG1 STATIC RESISTANCES Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 2 Add these resistance values to the available static resistance In the respective Blower Performance Table. 3 The pressure thru the economizer Is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system Is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. MOTOR AND DRIVE DATA - Belt -Drive Blower • M motors have solid bases and are Inherently protected These motors can be selected to operate Into their service factor because they are located In the moving air, upstream of any heating device. NOTES: 1. Utilization Range 'A' in accordance with ARI Standard 110. 10 EXTERNAL STATIC PRESSURE DROP 2. Dual element, time delay type. 3. Based on 60•C copper conductors. NOTES: 1. Utilization Range In accordance with ARI Standard 110. 2. Dual element, time delay type. 3. Based on 60•C copper condaclors. RECEIVED CITY OF TUKWILA Unitary Pro1149kIpt45 1998 PERMIT CENTER HOLE KNOCKOUT SIZE DIA. USED FOR A 7/8" • Control Wiring Side or Bottom)** B 2" • Power Wiring Side or Bottom C 1 -5/8" Gas P(• In' Front D 1.1/2" Gas Pi•in• Bottom Front DHB Units 24" DUC Units 32" Back 12" (Less Economizer) 36" (With Economizer) 24" (Less Economizer) 36" (With Economizer) 24" Left Side jFilter Access) Right Side (Cond. Coil) Below Unit 0" Above Unfit 72" (For Condenser Air Discharge) • V. ( UNIT DIMENSIONS (DHB AND DUC - 3, 4, 5 & 6 TON) DHB UNITS 3 -6 TON 314" PVC FEMALE COND. DRAIN (See Detail "A ") FIELD-SUPPUED DISCONNECT SNITCH LOCATION (Direct-Drive units) BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B • POWER WIRING ENTRY A • CONTROL WIRING ENTRY RLTER ACCESS DUC UNITS 3.6 TON 314" PVC FEMALE COND. DRAIN (See Detail 'Al Unitary Products Group CONTROL BOX ACCESS 8-33 BLOWER ACCESS CONTROL BLOWER B ACCESS ACCESS )JNIT BASE WITH RAIL Shown separate to !luau ea bottom duct openings end power oonnectlon Iocedons. NOTE For ourb-mounted unite, refer to the duct hanger dimensions of the curb for the proper size of the supply end return air duct connections. RELD•SUPPUED DISCONNECT SWITCH LOCATION (Direct-Dr/ye units) 32.515 7/8 A, d WIRING ENTRY (See Detail "81 BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B • POWER WIRING ENTRY A • CONTROL WIRING ENTRY 634 VENT AIR OUTLET HOOD CONDENSER COMPRESSOR ACCESS COMB USTION MR INLET HOOD 4a'a 7 GAS HEAT ACCESS GAS SUPPLY ENTRY •114 , (1/2' NPTI AT GAS VALVE) 2.112 D GAS SUPPLY ENTRY (2' NPTI AT GAS VALVE) 32•114 UNIT BASE WITH RAILS Shown separately to lustre,* bottom duct openings. power d gee piping connection loo NOTE: For curb. mounted unite, refer to the duct hanger dimensions of the curb Ior the proper size of the supply and return Sir duct connections. All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. ALTER ACCESS SS MOEDA FIELPDIN•LIEO DISCONNECT SWITCH LOCA UTILITIES ENTRY DATA 'Knockou s In the bottom of the unit can be located by the slice In the Insulation. "Do n j remove the 2' knockout ring. CLEARANCES 1 Units may be installed on combustible floors made from wood or class A, B or C rod covering material. 2 Units must be Installed oudoons. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. NOTES: DNB Modals; Unite and ductwork are approved for zero clear ante to combustible materials when equipped with electric heaters. DUO Modals: A 1' clearance must be provided between any combustible material and the supply air ductwork for a distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and redreuiate, Locate unit so that the vent alroutlet hood is at least • Three (3) feet above any forced air inlet located within 10 horizontal feet (ezduding those Integral to the unit). • Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or gravity air Inlet Into the building. • Four (4) feet from electric meters, gas meters, reguaitors and relief equipment. VN ENTRY CONTROL Sox IS•• Pw , l•e•) ACCESS ' mra -, l •T7,T..T�13 Er: fie^, lLt7i:rjf de•Tr i 3r.T:50 RETURN AIR SUPPLY AIR 530.18 -TG 1 CONDENSER AIR OUTDOOR AIR (EconEiEGil ED CITY OF TUKWILA MAY 0 5 1998 PERMIT CENTER 530.18 -TG 1 UNIT DIMENSIONS - CONT'D. (DHB and DUC - 3, 4, 5 & 6 TON) 171 REAR VIEW 8'h 171/2 SIDE SUPPLY AND RETURN AIR DUCT OPENINGS 7 111 111 16 REAR VIEW REAR VIEW 44 B ` APPROXIMATE CENTER OF GRAVITY FRONT BACK 1% 82v CENTER OF GRAVITY DETAIL "A" UNIT WITH ECONOMIZER RAINHOOD DUCT COVERS - Units are shipped with all air duct openings covered. For aide duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For bottom duct applications; 1. Remove the side supply air duct cover to gain access to the bottom supply air knockout panel. 2. Remove and discard the bottom knockout panel. 3. Replace the side duct cover. 4. With filter section access panel removed from the unit, remove and discard the bottom return air knockout panel. 5. Replace the filter access panel. 19V 447,t L.H. END VIEW DETAIL "B" UNIT WITH FIXED OUTDOOR AIR / BAROMETRIC REUEF RAINHOOD A 3 ..5TON 19 -3/4" 40-3/4" DIM. A B CONDENSER COIL END OF UNIT 6 TON 22" 44" RECEIVED CITY OF TUKWILA - MAY 0 5 1998 Unitary PrcO°NTER Le C , =wit SINGLE PACKAGE COOUNG & GAS HEATING AIR CONDITIONERS DCHB /DCUC090, 102, 120 & DDHB /DDUC150 7 -1/2 THRU 12 -1/2 NOMINAL TONS 8.5 -9.0 EER Mi& oo'n 530.18 -TG2L (995) DESCRIPTION These DHB and DUC units are convertible single packages with a common footprint cabinet and common roof curb for all 7 -1/2 thru 12 -1/2 ton sizes. All units have dual compressors and dual inde- pendent refrigeration circuits. The units were de- signed for light commercial applications and can easily be installed on a roof curb, slab, roof jack or frame. All units are self- contained and assembled on rigid full perimeter base rails allowing for 3 -way fork lift access and overhead rigging. Every unit Is com- pletely charged, wired, piped and tested at the factory to provide for a quick and easy field instal- lation. The units are available In the following configurations: cooling only and cooling with gas heat. Electric heaters are available as field - installed accessories. Both down and side discharge airflows are available without having to swap panels. The installer simply removes the duct covers for the desired configura- tion. Economizers may be used on either side or down discharge applications with no modifications required. All mcdcls Include a 1 -year limited warranty on the complete unit. Compressors and electric heater elements each carry an additional 4-year warranty. Aluminized steel tubular heat exchangers carry an additional 9 -year warranty. FEATURES COMMON FOOTPRINT/ COMMON CABINET - All model sizes and configurations share the exact same footprint cabinet - and therefore the same roof curb. You now have the flexibility of setting one curb and, after the internal load has been determined, placing the proper tonnage unit on that curb. You can even decide between cooling only or gas heat after the curb has been set. HIGH EFFICIENCY - All units have a minimum EER of 8.50. Gas / electric units have electronic spark ignition and power vented combustion with a mini- mum Steady state Efficiencies of 80 %. These effi- ciencies exceed all legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / return is desired, you simply remove the two bottom duct covers and discard them. No panel iteelIVIEDawapping Is required! Convert1b16i1Yrtt MUNId1*4 allows maximum field flexibility -And minimum inventory. MAY 0 5 Cont'd. PERMIT CENTER MODELS ARI RATINGS GAS HEAT CAPACITY COOLING CAPACITY SOUND 120 1 150 090 1 102 120 I 150 EVAPORATOR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. In.) TEMP. GAS MODEL 80 / 67 -95 °F RATING INPUT OUTPUT AFUE S.S.E. /°) S.E. /a) RISE LINE SIZE 4 MBH I FF.R (bets) (MBH) (MBH) ( /o) ( ( ( °F) (In. OD) DCUC090N165 90 8.90 8.8 163 130 79.0 80.0 72.9 30 - 80 3/4 DCUC090N120 90 8.90 8.8 204 163 80.0 80.0 74.9 30 - 80 3/4 DCUC102N165 102 9.00 8.6 163 130 79.0 80.0 72.9 30 - 60 3/4 DCUC102N205 102 9.00 8.6 204 183 80.0 80.0 74.9 30 - 80 3/4 DCUC120N205 118 9.00 8.8 204 163 80.0 80.0 73.5 30 - 60 3/4 DCUC120N245 118 9.00 8.6 245 198 79.5 81.0 76.4 30 •80 3/4 DDUC150N205 142 8,50 • 204 163 79.5 80.0 72.0 30 - 60 3/4 DDUC150N245 142 8.50 - 245 198 79.0 80.6 73.8 30 - 60 3/4 MODELS DHB DUC 090 1 102 120 1 150 090 1 102 120 I 150 EVAPORATOR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. In.) 12 x 12 15 x 12 12 x 12 15 x 12 FAN MOTOR HP 2 1 3 3 1 5 2 1 3 3 I 5 EVAPORATOR COIL ROWS DEEP 4 4 4 4 FINS PER INCH 15 15 15 15 FACE AREA (So, Ft,) 7.8 1 9,1 19.9 J 13.4 7.8 I 9,1 10.9 13.4 CONDENSER FAN (T1vo Per Unit) PROPELLER DIA. (in.) (Each) 24 24 24 24 FAN MOTOR HP (Each) 1/ 1/ 1 3 1 1 1 3 /4 NOM. CFM TOTAL (Each) 2900 3200 3600 4400 2900 3200 3600 4400 CONDENSER COIL ROWS DEEP 2 2 2 2 FINS PER INCH 13 13 13 13 FACE AREA (So. Ft,) 16.7 20.0 24.0 29,3 16,7 30.0 24,0 29.3 AIR FILTERS (SEE NOTE) QUANTITY PER UNIT (12" x 24" x 2 ") 2 2 - - 2 2 - - QUANTITY PER UNIT (16" X 24" X 2 ") 2 2 2 3 2 2 2 3 QUANTITY PER UNIT (18" X 24" X 2 ") - • 2 2 - 2 2 TOTAL FACF AREA (sn ft.) 9 3 9.3 11.3 14.0 9.3 9,3 11.3 14.0 CHARGE REFRIGERANT-22 b 7/4 8/0 10/4 SYSTEM NO. 2 6n/8 7/11 8� 2 10/8 6/8 PIQUE S/12 __ gEJy � 10/8 RATINGS CAPACITY RATINGS - Cooling / Electric Heating 90 102 118 142 ARI RATINGS COOLING CAPACITY 80 / 67 -95 °F MBH EER 8.90 9.00 9.00 8.50 SOUND RATING (bets) 8.8 8.6 8.6 • E MODEL DCHB090 DCHB102 OCHB120 DDHB150 208/230 460V MODELS ONLY CAPACITY RATINGS - Cooling / Gas Heating NOTE: AM gas units are two stage heating. First stags Is 70% of total, I Ratad In accordance with ARI Standard 210. 2 Rated In accordance with ARI Standard 360. 3 Sound ratings are In accordance with ARI Standard 270. 4 14eaters avallabls as accessories • all with single point power soppy. EER - Energy Efficiency Ratlo • the coding capacity In BTU's per hour (BTUH) dvlded by the power Input In watts at any given as( of rating monitions, expressed In BTUH per watt (BTUM ). S.S.E. - Steady State Efficiency. (Percent Output). S.E.- California Seasonal Efficiency • determined In accordance with test procedures as specified by the State of California Energy Commission. PHYSICAL DATA BASIC UNITS NOTE Filter racks are adapted for 1' or 2' thick filters. Unitary Products Group 208/230 575V MODELS ONLY NOMINAL LECTRIC H4AT CAPACI'T'Y" (KW) 9, 18, 24, 36 9, 18, 24, 36 18, 24, 36, 54 18, 24, 36, 54 Aso 9002 CERTIFIED' 7 -1/2 -10 TON 12 -1/2 TON MAY 0 5 1998 PERMIT CENTER 530.18 -TG2 3 ■ MODELS BLOWER RANGE (RPM) (Rpm) MOTOR' ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELTS HP SERVICE FACTOR FRAME SIZE EFFICIENCY (%) DIA. (IN) BORE (IN.) PITCH CIA (IN) BORE (IN.) PITCH PITCH LENGTH (IN) DESIG• NATION my DHB090 OUC090 975 -1220 2 1.20 56 82.0 3.4 - 4.4 7/8 6.2 1 50.3 A49 1 DHB102 DUC102 3 DHB120 DUC120 860-1090 3 1.20 56 82.0 3.4 - 4.4 7/8 7.0 1 57.3 A56 1 DUC1 0 960 -1140 5 1.15 184 82.0 4.9 - 5.9 1 -1/8 8.9 1 62.8 (Notched) 1 530.18 -TG2 • BLOWER MOTOR AND DRIVE DATA • AI motors are 1750 RPM. have solid bases and are inherently protected. These motors can be selected to operate inlo their seMce factor because they are located in the moving air, upabeem of any heating device. ACCESSORY STATIC RESISTANCES* 12 DESCRIPTION Economizer/Motorized Damper 2250 0.02 9KW* 18 KW Electric Heaters 24 KW 36 KW 54 KW*" 0.06 0.07 3090 0.02 0.11 0.12 0.13 0.15 RESISTANCE. MG CFM 4000 0.03 0.20 0.21 0.23 0.26 5000 0.05 0.31 0.33 0.35 0.40 6000 MODELS DHB DUC DHB eXTERNAL STATI9 PRESSURE DROP 'Deduct time mirttant* values from the satiable unit exlemal Oak pressure shown in the respective Blower Perbrmrwa Table. 'I) KW Healer Is only available on 7-1/2 and 8.12 Ton Units. ' KW Haim r Is only avertable on 10 and 12-1/2 Ton Units. COMPONENT WEIGHTS Basic Unit Accessories NOTE Weights are given in ponds. 0.07 0.45 0.48 0.52 0.58 COMPONENT DHB (Cooling only) MODELS DHB & DUC 7 -1/2 TON 1010 DUC (Gas / Electric) 185 Mbh 205 Mbh 245 Mbh Economizer Motorized Outdoor Air Damper Electric Heat (Nominal KW) (DHB only) 9KW 18 KW 24 KW 36 KW 54 KW Roof Mounting Curb 1090 1110 77 75 19 24 27 30 155 8.1/2T_ 1040 1105 1125 77 75 19 24 27 30 155 10 TON 1115 1215 1235 77 75 24 27 30 37 155 12 1/2 TON 1285 1485 1505 77 75 24 27 30 37 155 RECEIVED CITY OF TUKWILA MAY 0 5 1998 NEsaNMPoift Group MODEL POWER S COMPRESSOR (#1 and 1#2) OUTDOOR FAN MOTOR, (#1 & #2) FLA EACH SUPP AIR BLOWER MOTOR, FLA TOTAL UNIT AMPACITY, AMPS MAX. FUSE SIZE' AMPS MIN. WIRE SIZE, AWG R LA EACH LRA EACH 2HP 3HP 5HP 2HP 3HP 5HP 2HP 3HP 5HP DHB090 DUC090 208/230 -3 -60 460-3-60 575 -3-60 14.1 7.1 5.8 130 64 52 2.3 1.3 1.3 7.5 3.4 2.7 • - - - - - 43.8 21.9 18.3 - - - - - - 50 25 20 8 10 12 - - - - - DHB102 DUC102 208/230.3 -60 460-3-60 575-3-60 16.0 8.3 7.1 137 89 58 2.3 . 1.3 1.3 - - - 10.6 4.8 3.9 - - - - - - 51.3 26.2 22.4 - - - 80 30 25 - - - moo - - - DH$120 DUC120 208/230 -3-60 460-3-60 575-3-60 16.7 9.6 8.3 150 73 62 2.3 1.3 1.3 - - 10.6 4.8 3.9 • - - - - - 52.7 29.0 25.3 - - - 60 35 30 - • - co ma - - DHB150 DUC150 208/230 -3 -60 -+ `60 -3.60 575.3 -60 21.8 9.6 9.0 158 79 65 3.5 2.5 2.5 - - - - - - 15.1 7.5 5.9 - - - - - - 71.1 34.1 31.1 80/90 40 35/40 - - • - - - *mm (,„ FIELD WIRING - DHB /DUC Electric /Electric and Gas /Electric Units COOLING ONLY (24 VOLT THERMOSTAT) COOLING / HEATING (24 VOLT THERMOSTAT) UNIT TERMINAL THERMOSTAT' UNIT TERMINAL STRIP TB1 TERMINALS STRIP T81 THERMOSTAT' r + � - __ - '�� r R 1 TERMINALS I r -'- - -- I I - -. -- CO- -- I i I I C r - - --J I J GROUNO LUG Y11 V2 amt. X Al A2 CONTACTOR 1 24 Volt Thermostat 6TH0472124. 2 Terminal strip TEl • located on relay board In 24-volt section or the unit control box. 24 VOLT TRANSFORMER ELECTRICAL DATA - Basic Units CONTROL WIRINQ ADO JUMPER NOTES: 1. Dual element, time delay type. Maximum HACR breaker of the name AMP size Is applicable, except 575 volt units. 2. Based on 75•C copper conductors Unitary Products Group POWER WIRING I I r- J I I I 3-1 I I - -J f 1 I I I 1 FIELD•SUPPUED I I I DISCONNECT I I I I -- ,7 L L_______ - ---- t-°-i ...•0.4_ O-'- -. THREE I - - -� 4_43. ... PHASE POWER L - - 1 •--0" 1- ' . 0 --1-+ SUPPLY NOTE: Rata to electrical data tables to size the wire, disconnect switch and overcurrera protection. VOLTAGE UMITATIONS• V1 WI WI W2 - Al A2 530.18 - TG2 24 VOLT TRANSFORMER 1 24 Volt Thermostat 6TH0472024. 2 Terminal strip TB1 • located on relay board In 24-volt section of the unit control box. s•- o single Is not required on units g stage electric heater. NOTE: Control wire shall be solid class Roomer wire. Use 18 gauge up to 190'of max, wino length. Use 15 gouge when using more than 190' up to 350' of max. wire length. 'Utilization Range •A• In accordance with AR Standard 110. RECEIVED CITY OF TUKWII.A MAY 0 5 1998 PERMIT CENTER 13 UTILITIES ENTRY DATA HOLE OPENING SIZE (DIA.) USED FOR A 3/4" KO Control Wiring Side 7/8" KO Bottom' B 2" KO Power Wiring (Side or Bottom)' C 2" KO Gas Piping (Front) D 1- 11/16" Hole Gas Piping (Bottom)' Front 24" Back 12" (Less Economizer) 36" (With Economizer) Left Side (Filter Access) 54 r (With Economizer) Right Side (Cond. Coil) 24" Below Unit' 0" Above Unit 72" With 36" Maximum Horizontal Overhang (For Condenser Air Discharge) UNIT DIMENSIONS (DHB AND DUC - 7 -1/2 THRU 12 -1/2 TON) 1� 337!6 (003,102) 30 (120) 41.71e ( 150) RLTEI ACCESS RELO-IUPPUEC (A) DN06►.NECT MITCH CCNINOL WPM ENTRY =AVON SIP PVC F ALE aoat 0. DAIiN oosw. (aw Dewt pr Pew*, n (N rams ammo ENrM%•• pH D.111 'W b ioaaon) Ion SUPPLY AND RM IMS MR OPENSMOa (SEE NOTE) ELEC /ELEC UNITS 337IS (000 35.716 (120) 41.716 (150) ALTER ACCESS' 1415.041.1PPUm (A) o.cONNECT SWITCH Co 'OL wI1MN0 LOCATION 714' PVC Flew Li 0010. WPM caw. (b. DsM'Y' r 71 (A trowel wawa ENTRY few 0•01.t. v h.s.esle sorrow SUPPLY AID RETURN ASS dDINSS (BEE NOTE) I GASIELEC UNITS et14 (A) COMM. WIRING ENTRY (B) POSED wwwo ENTRY a.w (A) COMM IMMO ENTRY (B) POSER WONG ENTRY Unitary Products Group 7.114 SLOPES ACCESS "LONER ACCESS 7.114 `- ELECTRIC HEAT ACCESS COMPRESSOR Acura Mw 0.111 veto AM COMPRESSOR CUTLET MOO ACCESS ,(S.. 0 ') .111'x (0) OAS SUPPLY ENTRY coH n01t1FA cat. FRONT VIEW UNIT BASE WITH RAIL$ Sham wprary to Illustrate bottom duct openings and parer connsctlm locations. NOTE: Fa curb•mwned unite, new to the duct hangar Or*nstans 13.01 of M curb for the pope( titre of the supply end return aA duct 000nsottone. CONDENSER COIL COIMUIMON AIR INLET HOOD 37114 FRONT VIEW V IT BASE WITH RAILS 1114/2 bottom *matey to Ituevw bean duct openings, paew end gee piping canniesan locations. NOTE: For wrb+nwnNd urn,, rote( to Ni duct hanger dimension* 7.114 at all curb tor the proper elle of SW supply and return air dual cameo**, All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. CLEARANCES / RETURN AIR II SUPPLY AIR CONDENSER AIR r - - OUTDOOR AIR ,> (Economizer) PERMIT CENTER 530.18 -TG2 'Openings in the brAtom of the unit can be located by the silos in the Insulation. I Units may be Installed on combustible floors made tom wood or dass A, B or C roof covering material. 2 Units must be installed oudoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. NOTE: OUR is Units and ductwork am approved for zero clearance to combustible materWs when equipped with etectrlo heaters. DIM Mnrf.1•• A 1 • clearance mutt be provided between any com- bustible material and the supply air ductwork fora dstance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a writhed space and recirculate. Locate unit so that the vent air outlet hood Is at least • Three (3) feet above any forced air inlet located within 10 horizontal feet (exciudng those integral to the unit). • Four (4) feet blow, 4 horizontal feet from, or I foot above any door or gravity air inlet Into the bulking. • Four (4) feet from electric meters, gas meters, regulators and reef equipment. RECEIVED CITY OF TUKWILA MAY 0 5 1998 17 530.18 -TG2 UNIT DIMENSIONS - Cont'd. - (DHB and DUC - 7 -1/2 THRU 12 -1/2 TON) 18 DIM. A B c IMOD OVIDCON NA at WIOMETIrO ilea RAIN 1.000 REAR VIEW 7 -1/2 TON 33 -1/4" 47 -1/2" 8.1/2 TON 32" UNIT 441/2" 10 TON 32 -1/2" 46 -3/4" DETAIL "X" SIDE SUPPLY AND RETURN AIR DUCT OPENINGS DETAIL "Y" UNIT WITH ECONOMIZER AND FIXED OUTDOOR AIR HOODS 12 -1/2 TON 32-1/2" 45" RAI NOIIOEl1 RANI 11000 71° CENTER OF GRAVITY DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and retum air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For bottom duct applications; 1. Remove the side supply and return air duct covers to gain access to the bottom supply and return air duct covers. 2. Remove and discard the bottom duct covers. 3. Replace the side duct covers. APPROXIIAATE CENTER OF BACK — . ORAVRy CONDENSER COIL ENO 100 FRONT RECEIVED CITY OF T ��lk UKWILA Mt Ytat9 Prbd Group PERMIT CENTER City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Fire Department Review Control # M98 - 0091 Re: H.V.A. H.V.A.C. at Print Management - 6700 South Glacier Street Dear. Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto- shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. 'Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 2. Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) 3. In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) The installation of wiring and equipment shall be in Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1- 5.5.4) 4. When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall ' be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 5. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd John W Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 5754404 • Fax (206) 37. 541.39 July 13, 1999 Rod Christiansen 6605 — 200 Street SW Lynnwood, WA 98036 RE: Permit Status M98 -0091 6700 South Glacier Street Dear Mr. Christiansen: Sincerely, City of Tukwila Department of Community Development Brenda Holt Permit Coordinator Xc: Permit File No. M98 -0091 Duane Griffin, Building Official Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. John W. Rants, Mayor Steve Lancaster, Director In reviewing our current permit files, it appears that your permit for the replacement of one 8 -1/2 ton gas pac and one 5 ton gas pac issued on May 27, 1998 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431 -3670 • Fax (206) 431-3665