HomeMy WebLinkAboutPermit M98-0165 - OLD NAVYOf a f\I t ( 5 City of Tukwila c Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0165 Type: B -MECH Category: NRES Address: 17470 SOUTHCENTER PY Location: Parcel #: 262304 -9079 Contractor License No: MACDOM *248J9 MECHANICAL PERMIT TENANT OLD NAVY 17470 SOUTHCENTER PY, TUKWILA WA 98188 OWNER MBK NORTHWEST Phone: 206 - 575 -8090 C/O TRAMMELL CROW CO, 17560 SOUTHCENTER PY, TUKWILA WA 98188 CONTRACTOR MACDONALD MILLER CO Phone: 206 763 -9400 7717 DETROIT SW, SEATTLE, WA 98106 CONTACT JESSE MONTEZ Phone: 206 - 768 -4288 7717 DETROIT AV SW, SEATTLE WA 98106 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL '4 NEW ROOFTOP AC UNITS, GAS PIPING, DUCT WORK,, AND GRD'S, 4 T- STATS, 1 FAN, 2 WATER COOLERS 1 WATER HEATER EXPANSION TANK. UMC Edition: 1997 Valuation: 46,500.00 Total Permit Fee: 97.88 ******, I/ r *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Signature Print Name: a..+ri c•.. Permit Center Authorized Signature Date Date: Title: Status: ISSUED Issued: 09/04/1998 Expires: 03/03/1999 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. (206) 431 -3670 This permit shall become null and:voidif the. work is not commenced within 180 days from the date of issuance or -If . the work is suspended or abandoned for a period of 180 days from the last inspection. Project Name/Tenant: ?aakwrA. 5,...eA.pe.a,...k.- P/44 A9,4 -v y Value of Construction: ' 4 *1s of work - — -R -- -- — - - - -_- Site Address: City State /Zip: ____ :_.50 o Sou-ih. ca ..ti kw C W A 9 tee ff 1� Property Owner: (/ti 13k /0• Tax Parcel Number: 24,2-5o 4- S 02_9 Phone: 5 69'i 0 Phone: Street Address: City State /Zip: I (0 9,a , a /2/lo k- k-- ; 7 fA a L 1 [J ° Fax II: Contact Person: �rSSr / /nen , e-r - Phone: 206 -- 768'- ' ---g s' Street Address: City State /Zip: 77 / 7 [ � , r o T e i T AFL. 5 W C a i k i - 1 4 1 . . £ L i # 9'(06 Fax #: '/ Zp 6 -' 7 6 e `- 44 ' 0 Metro Contractor: n i o + c - e n 414-4. 1 44, t✓w- -6, Phone: z o 6 `-7 a- -4 e Street Address: City State /Zip: 7 7/7 D MO, r -4J) &), Se-414-4... oda ? Fax #: 7 - -'(Z Architect: ...... / r � c.v Ua. ' og -.� _ Phone: 6 6 )3 -6'31 - oz,3 4- _. Street Address: City State /Zip: 5 S c.a.) Ale•tavet.1% 1t2cL 64...e actAte GRA.. Fax #: 5 43 ( es 2.3 b Phone: Zarb — 74k - 42, t;' i Engineer: k-• - ______..7-___k_________44 Street Address: City State /Zip: 77, r , ri4ve cee so J!a- lci gi&roto Fax #: Z.or.-76& -42 co MISCELLANEOUS PERMIT ' REVIEW AND :APPROVAL .REQUESTED: (TO BE FILLED OUT BY APPLICANT) w + .W ^ - Description to be done: - • of work - — -R -- -- — - - - -_- Will there be storage of flammable combustible hazardous mat:nal in the building? ❑ yes alno Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes El Bulkhead /Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence ❑ Mechanical El Manufactured Housing - Replacement only ❑ Parking Lots El Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems Cl Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE. BILLINGS TO; Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby MISCPMT.DOC 7/11/96 CITY OF T" 'KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. 15153 ' 1 r APPLICANI,REQUESTFOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping El Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage Cl Water Meter /Exempt It ❑ Water Meter /Permanent # ❑ Water Meter Temp it ❑ Miscellaneous Applications will not be accepted through the mail or facsimile. Date application accepted: ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s) ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load /Hauling WATER'METER`DEPOSIT /REFUND BILLING: Name: Phone: Address: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application expires: Applic Ion taken by: (Initials) BUILDIN W.'•t3:0'FI`AUTHD T: SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks = Supported: directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW . Submit checklist No: M -9 - in Signatur / Z Submit checklist No:. M -1 f , 7, _____ -) Date: Commercial Tenant Improvement Permit `. /-7'q Print name: AO a jp , Submit checklist No M - 10 - Commercial Reroof Phone - if a _ q 10 .Xj11.., 7,7(77.- �7 —7 l Address: // /� / / ,, � /76 ,,,,,7_, ,...4 ?° � %c✓ -1 )7I y J � � Ci�O t, P Submit checklist,.. No: M - 2 i m %g/ ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks = Supported: directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW . Submit checklist No: M -9 - in Antennas /Satellite Dishes . Submit checklist No:. M -1 ❑ • Awnings /Canopies No signage Commercial Tenant Improvement Permit `. ❑ Bulkhead/Dock Submit checklist No M - 10 Commercial Reroof Submit checklist ..No: M -6 ❑ Demolition. Submit checklist : No M -3, M -3a Fences - Over 6 feet in Height :Submit checklist: No: ❑ Land Altering /Grading /Preloads Submit checklist,.. No: M - 2 Loading Docks; Commercial Tenant Improvement Permit.:: Submit checklist No: H =17 ❑ Mechanical (Residential & Commercial) ' Submit checklist No ' M-8; Residential ;only = H -6, H -16" ❑ Miscellaneous Public:Wor.ks Permits Submit checklist ` No H =9 ❑ Manufactured Housing:(RED INSIGNIA ONLY) Submit checklist No M - 5 ❑ Moving Oversized Load /Hauling Submit checklist.:' No M - 5 ❑ Parking Lots Submit checklist". No: M -4 ❑ Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit .checklist`, No:. M=6 ❑ Retaining' Walls - Over, 4: feet in height Submit :checklist' .' No :: M -1 ❑ Temporary Facilities Submit checklist,.: No M -7 ❑ Temporary Pedestrian Protection/Exit'Systems : Submit checklist .: No M =4' ❑ Tree:Cutting . " Submit checklist ; No M -2: ALL MISCELLANEOUS P 'IT APPLICATIONS MUST BE SUB • ED WITH THE FOLLOWING: ,AL3.. DRTi,WIN 9I4 BE AT A LEGIBLE SCALE AND NEATLY DRAWN B JLDI�IG iii.pGp AND UTILITY PLANS ARE TO BE COMBINED ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building. Owner /Authorized Agent, If the applicant is other than . the owner, registered architecderigineer. or.contractor licensed:' by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this;perrrilt.application :and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 CY CITY OF •TUKWILA Address: 17470 SOUTHCENTER PY Permit No: M98 -0165 Suite. Tenant: OLD NAVY Status: ISSUED. Type: B -MECH Appiied: 08/25/1998 Parcel #: 262304 -9079 Issued: 09/04/1998 ****` k *k ****•k•******* **•k•k ***`k•k•k l.**** k• k*** kA'* k• k• k` k** C• k*• k* *kkkk.4•kk•k•k*•k k*•k*k *Mk*** Permit Conditions: 1...No' changes will be made to the plans unless approved by the ;Architect or Engineer and the,1. wily Building Division. 2. All permits, inspection. r a }1ci:Nappr9y,ed plans shall be available at the ,}ob =site "pr to the s•t , a Hof any con- struct i on . The,se. `;are to'F' ma inta-1'ned ava i 1- ab l e until final i`nspect`,i pn 'approval is g ranted ` ; 3 . All construct.ton to .be done in° canfo 'nianee .with app;r~oved_ plans and ,r;eauir•ements.of the Unif,orni Build1nq=�.Code (1997 Edition)..:as'�amended. Uniform' Mechani'cale. Code "(199.7Ed*on), and Wash ington State ecificat '� Energy 'Co 997 Edition) ` ii . :4 `;' 4. Val i d i >tv� "of Permit The ; i s,q�rs de ni e. of a permit., or�prava�J:> °;o plansi,, pi . an�Zitromputa�tions shall 'not � c,�an , -, stru "be a permit, mit 'cor anapproval of any v of a' of the provisions of Ithe''bui ldinu code or =of arid rt 1:3 r 7 f., t . Y other�for:diriance of the iurisd'iction�: No permit pr.esumi to`', giue 'authors tv to violate cacancey the provisionsecof .,this code l be.r vat i,.d:. .. . , ,.,. s;..x 5, MANUFACTURER'.,'` INSTALLATION `IN O IpNS, - REI UIRED ON FOR ; THE , BUILDING INSPECTORS REVIEW I ' ,. 6. Pi .per inits sha11`' beobtained •thr the Seat -r Co 0pepartmeri of. Pub1,ic Healfh. Plumbing ,will be inspected by egency! ncl,uding ai f gas piping (296- 4 722 ) s, ' �: , . L ' •r t , 7, Ele ica1 permits shall be obt ained t h ° rough - tthe Wa sh { if ng State',` Division of Labor. and Indus•trl,e,si and`.al t el,e'ctr;i,ca.1 work '., w:�i 11: be inspected by that ai. ency k(248- 6630) 8, ' Readily . access,ibl'�e access t root mo equipment is f r o r e U u i r e d.• , f. 7 i I y.,, � )) S � a 1+ A�' 4 i t S1 y" }: '75 ACTIVITY NUMBER: M98 -0165 DATE: 8 -25 -98 PROJECT NAME: OLD NAVY XX Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Pu ui 4.? ding Division blic Work 24 Complete El Comments: TUES /THURS ROUTING: Approved \PR•ROUTE.DOC 6 /98 { PLA � /R�NG Fire Prevention 5? - 3 (1,Y S ructural � DETERMINATION OF COMPLETENESS: (Tues, Thurs) Incomplete E C Routed by Staff (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: REVIEWERS INITIALS: DUE DATE: 8 -27 -98 Planning Divisio Permit Coordinator Not Applicable El Please Route El No further Review Required El DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 9 -24 -98 Approved with Conditions Not Approved (attach comments) E DATE: CORRECTION DETERMINATION: DUE DATE: Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE. P Type�fin�e in: Address: P Date called: Speciallinstructi Date wanted: a.m. p.m. Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 pproved perjcable - odes. n Correctit5ns- = ! uired prior to approval. COMM t'ao1/4.(C. 9 $42.'0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must (206) 431 -3670 Projl/LD km (1 Type 2"t tJi� s r- Address: Sc p yi Date called: Date wanted: (/03/98 a.m. p.m, Special instructions: Requester: Phone No.: C;1 INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION RECOvn Retain a copy with peLjt Date: lr 913 - tA6 PERMIT NO, (206) 431 -3670 Corrections required prior to approval. Inspe s �• a it $42. I rREINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 6 Receipt No.: Date: Project: 0 Q n hi , y( T oc i po p�cti i o LA - Address: 1 �.Lli-tx I4��Sa P� Date callleed: rar q� Special instruc ions: � �� . 12 - .00 rp 5S ( �)� Date wan t g a.m. P.m. R equest er: T „ Phone ) No O( 57o -1(c' O2— IN PECTION NO. pproved per applicable codes. INSPECTION RECO Retain a copy with pe _.fit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �,��/ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) (206) 431 -3670 Corrections required prior to approval. i Am. _ le , r $42.00 1 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sc edule reinspection. Receipt No.: Date: City of Tukwila Fire Department Project Name C NaV".2 Address \14 0 .c017.;\ v . N Retain current inspection schedule Needs shift inspection Sprinklers: Fire Alarm: OJA(... Hood & Duct: Halon: Monitor: Pre-Fire: Permits: 5(0 Authorized Signature FINALAPP.FRM Rev. 2/19/98 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM X _ Approved without correction notice Approved with correction notice issued John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. Suite # T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 • • • • .JrA***A*4.*****A***A*A.***A**Jr***A*A*A*:k***A.h*A***.k*******A* “Y OF TUKWILA. WA . TRANSMIT AA4 lliANSMIT Number: R970085 Amount: 97..08 13123 Payment.Aethod; CHIICK Notatton: MACDONALD MILLER: :Cnitl flt H •Permit No M98-.0165 Type:A-MC.1:H MECHANICALPERMTI. -- Parcel Not 262304.-9079 . _ Site Addrees: 1?l7() SOUtHCL TLI PY Total Tees: 97 .Pa' Thi's Payment 97.11B . Total ALL Pits: Account Code ' Description AmbUn.: 000/345.830 PLAN CHECK - AONRES, - 1 000/32.100 MECHANICAL ✓ Working Drawings Floor plan ./System layout ,..- Elevations (for roof mounted equipment) and proposed screening ..- Heat Loss Calculations r , Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504(e)) H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut -off and will be routed to the Fire Prevention division for additional comments, code section Uniform Mechanical code 1009. Provide 2 sets of manufacturer's installation instructions ✓ the Document Requirements Documentation or specifications must be provided to show that replacement equipment complies with efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required to replace existing roof equipment weighing 400 pounds and greater (Uniform Mechanical Code Section 2336(a)) Water heaters and vents are included in the UMC - please include any water heaters or vents being installed or replaced. Structural calculations stamped by a Washington State licensed Structural Engineer shall be required if structural work is to be done • Number of units Provide 2 sets of manufacturer's installation instructions ✓ Working Drawings On 8 1/2 x 11 sheet of paper include the following: Narrative of work to be done (i.e., changeout, replace existing equipment, modifications, etc.) • Type of unit being installed • Rating /Size • Number of units Provide 2 sets of manufacturer's installation instructions Note: Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced Miscellaneous Permits CITY OF T "'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 MECHANICAL PERMIT ► M -8 Submittal Checklist COMMERCIAL: Four complete sets of drawings and attachments required with application submittal t. RESIDENTIAL: Four complete sets of drawings and attachments required with application submittal 2/97 pm '' P MECHANICAL CONTRACTORS 7717 OU T AVENUE S.r SOME w IUD i.4 - m -zuaa PHONE (206) 763 -9400 MACDONALD- MILLER CO. APPROX. 5' UNIT HEIGHT NO SCALE NOTE: OLD NAVY APPROX. HEIGHT 18' FAX (206) 767 -6773 5O' MIN EQUIPMENT ELEVATION DETAIL RTU -Q SHOWN, OTHER UNITS SIMILAR. 5'- 3" LOWEST PARAPET HEIGHT BLDG. FRONT AUG -19 -98 11:23 FROM -KPFF Elaa Corrs':tti!g L':ggiro °.:S August 19, 1998 McDonald Miller Company, Inc. Mr. Jesse Montez 7717 Detroit Ave., S.W. Seattle, WA 98106 -1903 RE: Parkway Supercenter Old Navy Mechanical Tukwila, Washington Dear Jesse: Attached please find calculation sheets, 1 through 7, dated August 19, 1998, which verify the structural adequacy of roof mechanical supports for the Parkway Supercenter, as shown on sheets S1 through S4, dated August 19, 1998. Design is based on the requirements of the 1994 Uniform Building Code, as amended by the State of Washington. If you have any questions or require further information, please call. Sincerely, Jarod M. Winnen Project Engineer Attachments 1JMW:kw 197552.09\0819cel.dool APPROVED p 1 1998 NG iVI50 503 -227 -7980 s.. PIRus: 9/12/00 ? '.9 ),� .:i [ :.7' .a'7•.i�j1 : 7 : ; ^ • 22/ Seattle Portland San Franclsco lnx Angeles Phoenix San Diego frl' T -007 P.02 F -907 RECNIYEO CITY OP TUKWILA AUG 2 5 1998 PERMIT CENTER AUG -19 -98 11:23 FROM —KPFF .n:`A^.S. C.:i A:$ 1 • • h.\ M . ?roluct •.. Effri Consulting £nptneers lIrl7tan Gent Psi P�c-J.4 -Y f -4 1.4.4 5 yc,C & L f 9i r �•r�— 3. / 1.1 Ps; ( ') Jr 9• d ' 2. -7---L1;2°4 �- 4 • - •—r — a in C 'k 0. 503 -227 -7980 T -007 P.03 F -907 ev 27 k �.,. 1 7.,; - k. l- /rT( —• r ,r a.G a O . ? •uo 0.4 . ... ,_.1,1 k r..am v4,. i- 51 } i AUG -19 -98 11:24 FROM —KPFF 503 -22T -7980 T -007 P.04 F -907 D .t:C:.tl. cr {rope:' _cr..en" Consulting Engineers CJcrr` /4•r.f••••• F :.rf 5 - 5:1.4 • 9 ) . ` /* ._._ lam .�..: I a r /i,.. /1" t. r 9+ - ' C•.Y.O.c•rc S Ir.E.4(1— V er o. 66 (47/6- /err) Z PA -hoc I . .� o• Ai L.S r ti. / Z °r J sLlw acre 53//9'//99 MICA NC. c% : r_ 2- c .�a: J ,./ ( tic 4. r 4.1, • , lc. Z c •4; (' / ,.a•Gf k_ y 4 4 c. /b *• A'sI 5 .c JS t . �� _ S ^� --------- •e" - 5 )_ 3 ... - - - - - _ AUG -19 -98 11:24 FROM -KPFF P•o;tx:: I::cr. "ar Cat:suiting Englysers Purru. Ote;a c; er: • m , r 2, 503 - 227 -7980 p, L Jtt /„ (" Z.., v.. ,> ` Z o 3.. T -007 P.05 F -907 Rweled ::cto rwei No 4( • :at. (tit AUG-19-98 11:24 FROM—KPFF . • 415711Consultt,i; Eng Insets Itr! d, CreGnil 4 "/...*- rtf /4. C• /4. . As.c Ac - r - • •: r ) 7...4 0 P10:7 LI ter" a P 42C: 503-22T-7980 • drie 3y Cote . 2toiscd C:clo z. / c,e 0 4 4.4.4 $ •"/ " e/ . 44110 A.9" 1 c,,v4r e. 4 ct . , ese eft- t . c. T-007 P.06 F • • • Vcot No. an, Yo. AUG -19 -98 11:24 FROM -KPFF 503 -227 -7980 T -007 P.07 F -907 KPFF Consulting Engineers Portland, OR I Rev: eoaco+ Description 25' Tube steel General Information Center Span 25.00 ft Moment of Inertia 45.100 1n4 Lett Cantilever ft Elastic Modulus 29,000 kst Right Cantilever ft Beam End Fixity Pin -Pin 1 On Center Span... On Left Cantilever... On Right Cantilever... # 1 0.025 k/ft # 1 k/ft # 1 k/ft Point Loads Uniform Loads Magnitude 0.879 k 0.679 k 0.679 k Location 0.010 ft 8.000 ft 17.000 ft rTrapezoidal Loads Center Location 20.000 ft Moment 9.48 k -ft Shear -1.39 k Deflection - 0.71902 In Summary Moments... Max + ® Center 12.99 k -ft at 12.53 ft Max - © Center 0.00 k -ft at 0.00 ft CO Left Cant 0.00 k -ft Right Cant 0.00 k -ft Maximum as 12.99 k -ft Single Span Beam Analysis Magnitude 0 Left 0.175 k/ft 0.175 k/ft k/ft k/ft Magnitude 0 Right 0.175 k/ft 0.175 km k/ft k/ft Dist. To Left Side ft 17.000 ft ft ft Dist. To Right Side 8.000 ft 25.000 ft ft ft uery Values 1 Left Cant Shears... et Left ® Right Maximum Deflections... Center ® Left Cant. Right Cant Title: Dagnr: Description : Scope: ? 0.000 ft 0.00 k -ft 0.00 k 0,00000 In 3.07 k 3.07 k 3.07 k -1.191 In at 12.47ft 0.000 In at 0.00 ft 0.000 In at 0.00 ft Job Ir Date: 5:13PM, 10 AUG 98 0.879 k k 24.990 ft ft Right Cant 0.000 ft 0.00 k -ft 0.00 k 0.00000 In Reactions— 41) Left ® Right 3.07 k 3.07 k Page 1 1 1 AUG -19 -98 11:24 FROM -KPFF 0.6tk 0.67k 0.17k/f 1 ffl 0.17/t 0.02k/ft , 1 T P T T 1 1 ' T 1 1 1 1 1 R1= 3.070k V tnux Gj left = 3.070 k 23.00 ft 0.6 / k Amax = 12.99 k -ft ad 12.52 ft front lett Dttutx • - 1.1913 its of 12.47 ft from left 1 503 - 227 -7980 T -007 P.08 F -907 0.17 k/ft. l ; f ; i 0.17 6iit �ro1l,ti ;rr�r, ii V 0.6ek. 1 0.02 k/ft Rr =8.070k Vtnax /it 'rt= 3.070 k Fire Department Review Control #M98 -0165 (512) Re: Old Navy - 17470 Southcenter Parkway Dear Sir: City of Tukwila Fire Department August 31, 1998 Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Fire alarm systems shall be maintained in an operative condition at all times. Fire alarm systems and their component parts shall be inspected and tested per manufacturer's specifications and N.F.P.A. 72 at a minimum frequency of every twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire Prevention Bureau. (NFPA 72 (7 -3.2, 7- 3.2.1)) (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax. (206) 57;4439' Yours truly, (- City of Tukwila Fire Department 72 (1- 5.2.8.2)) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) 2. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 3. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. The Tukwila F' tion Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Ftre Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 57$4404 • Fax (206) 5754439 c ( Dt.t.h.li And Display Certilluiti.‘' DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CCO1 MACDOM*248J9 08/01/1999 EFFECTIVE DATE 04/29/1976 MACDONALD MILLER CO 7717 DETROIT AVE SW SEATTLE WA 98106 Dt.tacli And Display CertitiLak. SEE REFLECTED CEILING A STRAP W/- 3/8 " LA SCREWS INTLOCKING IXt STUDS A HEATER I • - r ' FHc COPY _ ,. ,unstand that the Pan Check apP soblecttoerrorsandomissionsan daPP oval Ions dues not authorize me v�olanpn of anV f c on iadoPfed c °ae or ordfnancsd e ckN p ou` l e d 9ed . `Tractor sr 'f roved p _�— t BY . , I " Date \ • � � u E - Permit Np. a- SLOPE aim PBDANr ADAPTOR BY ELECT. Carr. W/ SWIVEL BELT RUNG - PAM ® _ RODE S11 UC1 J E P2 NsuATON4 SACS) .: SL6PBD TG DECK ABOVE BOO ( 3/8' DIA. TFFFA Roo FE SE LENGTH.) aF MAX. 6' -0' LENGTH.) BY ELECT. CONTRACTOR. MC CABLNG CR RE( CONDUIT VA-BE PEWEE) PROVIDE 4' SLACK. MN. TO TH FADED RCO PLAN FOR LIB`XiTFI(S) OF JJNO TRAC -MASTa , TYP. 4' -0'. 7Aa CIE- SYSTEM RAW STEEL FINISH' 1110 MAIN WCT(S) WI S 1 - THIOW D IF}i)SERS PA a P2 D ATIV LIGHT SE JUNCTION BOX AT STRICTLIE • VAR�S 11t11III I .... Z i tr 1 T T • 9'-0 TYP C _ MUSIC r• 10 GALLON WATER - - FEA,TER 75LBS - .) SEE p,L lq(�If,AL:SPECIFICATIONS. FOR EXACT MODEL AND MANUFACTURER - - n . • CTI�4j j'tj 4 e� js /d V� LTj'♦ et1 `•� MC CABLING OR FLEX MC CAB WHEN RE( SECIJf)E G EED. P AN) RN AND ED F®. PAM 21 1,,,F-0' VIE. F. MN. CLA AT STPJCT. ►'� ' ®� 24 GAGE LV AND END F. PAM N D I3 P2 9ti-0 DUCTS\ y '. AT 2/3 HEIGHT - ) ®� GA. TL. DRAIN PAN LIjr TT ,, ®Q • S STUD WALLS . . STUDS (TYP)- ATTACH 2 X 4 FR WOOD 9.KG. TO UDEISDE OF STRUCTPAM _� � SECURE fXl`i1UIT T THfEfl� ROD I ABOVE M � 111 in � - _► /� FOR RIGIDITY, JOIN ADJACENT .END TRACK t/ W/ 6' FI AT BAH JL4D PART !E/ ANGLE BRACKET (TYP. 2) .�i *12' -0' A.F.F. I I S I a 3/B" LAG -SCREW (4 MIN.) FLUOR. LIGHT. SEE. ® _ _ INTO BLOCKING OR STLAS O ® —"� FBDANf-tING ® .. . TRACK LIGHT. SEE. lap o JLtD ME- CIRCUIT TRAC- MASTER SYSTEI4 DISPLAY SHELVNG Y EE CMNE ENE t3D_ _ -.. 1 u'1 INCA/DESCENT SHOWN DASHED LAM' HOLCER - CUSTOM FINISH - CONC. FLOOR �a-0' FALSE PILASTER BOOTH$ET CORNER PLASTER (WHERE OCCURS TRACK LIGHT ASSEMBLY 3"=1'" ° 15 —LIGHT TRACK SUSPENSION N.T.S. 12 SCHEMATIC SECT IQ 1/4 -° WATER HEATER (PLATFORM MOUNTED) 3/4"=1'-0" 10 N11A08 01 A r:__ A.F.F. I URFACE MOUNTED HAND aiYHi JUNCTION BOX RCP FOR LOCATONS. PAM m ELECTRIC 1/ GYP. B). CEILING 1 ' CAULK All AROUND WITH WHITE SEALANT. WATEL RESISTANT GYP. BD. p 1 �I r � I I. GYP. B. PANTED TYP WALL I 0 VARIES I III 2' DIA. GALV. 8.0. StR.I FACTORY FNISH T ML PIP LEGTH E VAPoES. AY 8' -0' A.F.F. ' 1 M TYPICAL ALL .WALLS. PAINT MARLITE WANSCOT FNISH EXPOS® TCP EDGES WITH W1 SUF ACE MOUNTED STANDARDS AT 2' -0' O.C. SAFE- CAULK W/ BACKNG ROD IF NECESSARY. (OMR StN3VNG AID STANDARDS WHEW OCCIASL ` I I I , Y4i I - 1 r - - J-MCLD TO MATCH WAPSCOT �OR�AN HOT L� �' ti g — ®I �' WAS BASE O - SHEET .VINYL COVED - I OF ♦ 3 TO A RNN 4' VINYL BASE. TYP. -0�' Alf. Al - SURFACE ? TRASH CAULK ALL AR:u W WHITE SEALANT WATER RESISTANT GYP. BD. 3' -0' .® LIGHT FIXTURE 1/GYP, BD. CEILING FLE NLD) TYP OF 2 (BY GAP PINC(ASMIG) CAT B PRINTER PI I CJ CONTNJOUS COUNTER WNG WALLS 133.0W. P.O.S. CONECTIONS. SEE EEC. DWGS. 4' APPAL BASE 81 i i I ♦��4■u• I A,, I I TYPICAL ALL WAIJ.S. PAM P1 WALL MaNTID LIGHT F AND WALL u ... INCANDESCENT SEE NEA LIGHT EEC. FIXTU€ SUED. ``o k —� I R3XB? 'TEE' W/ � �ll I I , I I I I I MIRROR. PROVIDE SHIM BEHIND ABOVE WAINSCOT FOR AN E MOWING SINFACE. CAULK / WITH WHITE SEALANT. SHAT COVE( DISPBNSut w / i / � L v = w CASE( fEGS� N.I.C)� O0 G I TOILET M W/ SLOT DOWN. _ �� .AT (»"e BAR CONTROLLER N.I.ca PHONE JACKS TYP. a) LOCATIONS NEXT TO OUTLETS WING WAIL SIPH'ORTS INTERIOR ELEVATIONS N °iTi�_j 4 -6' = _ �, a ' 10 O , � A6.3 . - . � SOAP DISPENSE MOUNT (3) NICKEL CHIME PLATED SO(EWST •8..X 1-1/2' MIN. RUTH WITH BOTTOM OF MIRROR 1 6 ' 6 MIN- I /� v CAGFNVHAP CCINTH( • 5'0" 0.C. CUR. 6 , -9 : . JO NOTE: SIMLAR SUSPENSION AT STE JOIST CaSTRUCTDN MIN. PENDANT LIGHT ATTACHMENT 1jZ 14 POWER RACEWAY SUPPORT 1/2 N11C0 ' 0 11 HYP. MGR'S OFFICE ELEVATION) 1/4 1' 0 1 8 N9B02 ar 2X4 Ff TAHDANT BLOCKNG ATTACm TO LNDELSDE OF ROOF PULNS O WIST RUT P I000 AT Sm. JOIST NOTEr D0 NOT IAN )NISTRU IPAST B S CF FIXRNES T EBHaE 'AD'S WATER RES TAN T GY P. BD. ay- F r, u .,. _ 1 oc�f,'\\�AL o 1 O w - ` _ Al SOT . FNIN W1 � 2' -0" ' ATTACH R 1 1l1C W/ WST PXI00 T(S' I "` v ) P.OS. 8 ECT / t$ / TP S WITH J#IOLD TO MATCH WAINSCOT 2 V4' 11+031 BOLT -��1 C 43) 2 V2. DIA. OPES - a� � �, B.EIRIOAIJ CA . �I-� WISTRJT �P2D82 BEAM CLAMP W WISTRUT'P2677 HANGER PAM P2 'P2879 '. 1 1: � I�I • I �� ELES N IC) TYP _ / o000000000opo0000000000000000 � � NB W _ DOUBLE TOLET PAP(31 DI :.. • _' 1 W, �� � < m �- �' J BOX W/ COVER PLATE BY E.ETRICAll WISTRUr 8 SWIVEL NUt V PAM P2 j CONDUIT JWCTICN BOX- MINTED • TYP. LOCATION T}BAADSTATTi, VERIFY WITH AEO TIERM ` \ - Q 10 ®� A6:3 COUNT WITH 3f8'. S. TFrx AT e' TO 'p' O.C. = LNOEtSDE OF STRUCTUiE _ CABLING OR RE( CONDUIT WH EFE REiUIRHD. PROVIDE 12' SLAM(. MN. OUTLET -TYP OF 4 FUl- 1-EICHT SLFACE- STANDAFOS 8 SIE_VNG. SHEET VINYL COVED BASE )• 12° .. I OF DISPENSER 2 O —. LENGTH VARES) PAM P2 MOWTO2 WALL 1 � 2 i . � 1 GAUG WEST PBN 224 1 RUN OF W T B.EI (B GAUGE 2 COED. WYE ' (WIRE PROVD® BY MUZAK II ND FULLED EECTAICAL) '"2855 RACEWAY W NGI33 HAN$L AT B' TO B' O.C. PAM P2 _ SECURE TO THREAD® ROD AHD END Fes. r e ' SAFE NIC) AO. FLOOR PLAN j 'P1(108 II WISTRUT SPRING NIT � -. TYP. LOCATION FOR 4 -WAY HVAC SUPPLY VERIFY WITH 1 X 4 SUFACE -MTD. FIXTUE W< PRISMATIC ACRYLIC DETiSBi CaNTEi BELOW (SHAWN DAB) L VERIFY WITH NEC♦. GYP. BD. CELNG 1/4' X 4' EYE BOLT (BY L COATED WEE ROPE / .1 r CONTNJOUS' WISTRUr TIC00-20GR HS US E N IN �' LENGTHS MAX USE aw*a P2 I' N COAT HOOK I` — Uz LLLL 4 -0' GN .E. owes. _ SWITCH LUG1iT ®Y WINO (BY 3116' WICK LINK NY MJIAK) ATTACH CH CFEW TO FDC WITH- AND HEX NUTS TWOTATTACHI�RS PER 4' FIXTURE AT 24' O.C. al � / O —�— — SH$T VINYL COVED BASE 1 .. .. �/ °' s "' TL.1c >? A BUILDING DIVISION f •,' RECENED elrroFTUICwILA ; ii , ? ; 156 _ .. NSTALL ACCESSORIES WITH T BREAST CO�PARTMBNr INTO L NG , - - WEE SOlJ OEAIBi WIRE IL J-0OX ABOVE NY A4.IlAK) 2-LAW FLU:MSC:ET FIXTUFE WITH LOW-PROFLE WIFE GUARDS ATTACHED TO MIRE WITH ; �.. DINGS. .. D ( HINGE CLAM'S `AFF. NOTE= PAINT Al All kFTAL FITTING AM WOOD RI P2 NOT.. O CAGE - AT 8' -0• A.F.F. Pl WETE= S NGLE SPFAlBi XPfT� M IBS. ® T -0' AFF. J FOR morrow. NOTES SEE E.ECTRICAL auwNGS I NOTE ELECTRAAL CONTRACTOR TO PROVO SEISMIC BRACING Pet LOCAL WILDING CODE RIEOUIREP,ENTS ® REFLECTED CEILING PLAN (SINGLE 1/4" _ l'-0 PERMIT CENTER NO SCALE 3 " = 1' 0" t 1/4"=1'-0" ? TOILET ROOM ELEVATIONS OCCUPANCY) N9AOZ SOUND SPEAKER SUSPENSION N11BO2 13 FLUOR. LIGHT SUSPENSIO N11A07 1O HYP. MGRS OFFICEc .AN�RCP) N9B01 GAP GAP, INC. CORPORATE ARCHITECTURE 900 CHERRY AVENUE SAN BRUNO, CA 94066 -3010 (415) 952 -4400 REV. DATE. ISSUE FOR :. 07 - 09 - 98 PERMIT AND BID SET BY: RK PARKWAY SUPERCENTER SCALE; DECKED MIKE: MCKEON STORE NLM3ER: SHEET NUMBER: 5359 1 A6 AS NOTED DATABASE & FILE NAME: /home /Richard Wd ir.5359_p /shl.A61_BD BASIC DELIVERY REVISED: MAY 1998 SECTION 15200 HEATING, VENTILATING & AIR CONDITIONING PART 1 - GENERAL 1.01 SCOPE OF WORK A. Complete air conditioning, heating and ventilating and exhaust systems including all equipment, fans, piping and ductwork as indicated. B. Provide smoke evacuation systems as required by code, Landlord, or local authorities. C. Insulation of piping, ductwork and equipment. D. Temperature controls and wiring for controls and interlocks for equipment and systems which are part of this Section. E. Testing and Balancing. F. Guarantee: The Contractor shall leave the entire installation in complete working order, free from any defective meterial, workmanship or finish. The Contractor shall assemble certificates of warranty and /or guarantee and fill in all necessary information except purchase date, in favor of the Gap, and furnish one copy of each warranty or guarantee to the Gap. The Contractor shall guarantee for the entire installation, to repair or replace, without charge, defects due to faulty workmanship or material for a period of one year after acceptance. Compressors shall be guaranteed for an additional four years. 1.02 SUBMITTALS A. Submit complete submittals of equipment, air terminals, and controls to Gap for review. B. Submit mechanical shop drawings with complete schedules to the GAP for review prior to fabrication. C. Submevieit w. complete test and balance reports to the GAP for r PART 2 - MATERIALS AND EXECUTION 2.01 DUCTWORK A. Shall be galvanized sheet metal constructed in accordance with the latest SMACNA Standards. B. Round supply ducts exposed in Sales Area and Fitting Rooms shall be phosphatized or paintgrip spiral galvanized uninsulated sheet metal (no flex duct allowed in sales and fitting areas). C. Return duct shall be lined rectangular with n elbow turned horizontal so that the return grille(s) is (are) in a vertical position. D. Ducts shall be exposed in Sales Areas with bottom of d cts no lower than 13 ft. above floor (unless otherwise noted installed in a straight and true manner parallel to building lines and pointed per GAP s finish schedule. 2.02 AIR TERMINALS A Shall be as scheduled and selected for NC 30 maximum. B. S CLM upply maxi diffumsers um in per Sa diffu les ser. Area shall be selected for 700 C. Return grilles shall be installed in the vertical position. 2.03 DAMPERS A. VOLUME DAMPERS Provide motorized control dampers where indicated on the plans. 2. Motorized dampers shall be parallel blade and shall have cadmium plated shafts and nylon or teflon bearings. 3. Motorized dampers in medium pressure duct system and smoke exhaust systems shall be AMCA low leakage rated with blade edge seals and jam seals. 2.04 FIRE DAMPERS & COMBINATION FIRE /SMOKE DAMPERS A. Fire dampers shall be Ruskin as follows, or equal UL listed and labeled for the intended use and shall be installed strictly according to their listing requirements. D -IBD -2 Style B - For ducts less than 12" high with blades stored out of air stream. D -IBD -2 Style A - For ducts greater than 12" - blades entirely within air stream. D -IBD -2 Style C - All medium and high velocity ducts. B. Provide access panels in ducts and walls or ceilings as required for access to each Erg damper. Duct access doors shall be labeled with 1/2 high letters FIRE DAMPER'. GAP Gap, Inc. Corporate Architecture 900 Cherry Avenue San Bruno, CA 94066 -3010 (650) 952 -4400 C. Combination e /Smoke Dampers: shall be Ruskin FSD 37 or equal, State a Marshal fisted, UL listed (UL 555, UL 5555 and ledge class 1) and labeled for the intended use. Provideisible link electric actuator tested and listed with diper. Actuator shall have contacts for smoke deter; signal. Provide duct detector as specified elsewhere. [riper shall be normally closed and shall close on sme detection or fusible link melt. Actuator shall be out the air stream. Provide access to.each damper in des and in walls or ceilings for servicing. Label dgct cress doors with 1/2 high letters FIRE /SMOKE i DAMPER . ,nail n strict accordance with manufacturer s instructions d listing requirements. D. It is the Conictor's responsibility to provide fire dampers andre /smoke dampers where ducts cross fire rated assemks and as required by chapters 7 and 9 of the Uniform iilding Code. 2.05 EXHAUST FAN A. Provide exhai fan(s) as scheduled for toilet rooms and janitors closi wired with the auxiliary relay output of Stockroom tkmostat. Turn fan on and off with the other HVAC equipmt. 2.06 ELECTRIC VE5BULE HEATER A. Provide Luxaif or equal, air handling unit with electric heater as- soduled at entry vestibule, unless prohibited by code, whet winter outdoor design temperature in below 25 F (ASHR /99 %column). 2.07 HEATING & C)LING EQUIPMENT PART 3 - CONTROL 3.01 SCOPE A. Furnish and hstall temperature controls as hereinafter specified or is shown on the plan sheets. 1. Provide butterfly or multi -blade volume dampers of all low pressure branch mains and branch duct connections, unless specifically noted otherwise, and where indicated on the drawing or required for balancing air quantities to values shown without excessive noise. Provide a Duro -Dyne KS -385, or approved equal, locking C. quadrant on each manual damper. Provide access panels to all dampers which are not otherwise accessible. Dampers shall be constructed as shown on Fig. 2 -14 1 p g 2 & 15 in the SMACNA Duct Manual. 2. Provide Titus Model AG -45, or equal, air extractors with operator for operation through grille of diffuser only where indicated on the drawings. B. MOTORIZED DAMPERS 3.02 A. B C. D. 3.03 A. B. A. B. C. Existing heatg and cooling equipment shall be less than 8 years old id shall be in good working order. Submit complete anidetoiled service records. GAP, at their discretion,, my accept units older than 8 years if Landlord will uarantee no units will be down for more than 48 hou<.and take full responsibility for service and repair of um National_accot agreements have been made between E.B. Ward Co. aniFisher Development/GAP, Inc.- Equipment pricing shoul£.be obtained by contacting Richard Frenzel at F B. WariCo. 337 Roebliing Rd., South Son Francisco, CA (415)872525. The equipment specified on MP1.0 is being held fcethis project and will be released by E. B. Ward Co. upe the mechanical contractors purchase order. A purchase (der must be issued to E. B. Ward within three working daysof contract award with Fisher Development., Where witer outdoor design temperatures is below 25' F (ASHRAE 99 ;column, provide an electric duct heater, ED- 1, for the brnch serving the vestibule. Where witer outdoor design temperatures is below 25' F (ASHRAE 99 %column, and the there is a stockroom door to the outside, povide an electric unit heater UH -1, or equivalent ga. fired unit, with integral thermostat near the stockroom dal. All control and interlock wiring shall be furnished and instated by he control manufacturer in EMT up to 12' off the finish tier. All other wiring shall be installed tight to struaure and in good workmanship, like manner. Devices that are specified as coming pre -wired from the factory shall have their external interlocks performed by the control nanufacturer. The Contractor shall secure the complete wiring diagrams of the various pieces of equipment, such as the fan units and compressors and these shall be incorporated into the overall submttal drawings. Submittal drawings shall consist of actual fan system, layouts on not less than 24" x 12 paper and these shall be in complete detail. There shall be complete interlock wiring diagrams for all the various place of equipment and there shall be a complete sequence of operation for each system. At the completion of the Job, these control drawings shall be duplicated in , rii,vx size 'and mounted in plastic envelopes together with sequence of operation and shall be posted in the various places as called for by the GAP. THERMOSTATS; SUBBASES AND SENSORS Thermostats shall be programmable Honeywell Model T7300 with Q7300 subbase,. remote sensor, push button override capabilities, and auxiliary contact for exhaust fan start and stop as described above. Remote sensors shall be Honeywell Model T7047C1025 electronic space sensor with blank cover. Sequence of operation for units shall be: 1. Occuppi hour: snt fan opon, oling set point of ed 73' F and consta heating setpeiet erati of 69 ' F. 2. Unoccupied hours: fan cycles on for set back operations, cooling set back set point of 90' F and heating set back set point of 55 F. Thermostats or sensors on outside walls shall be mounted on 1/2 plastic insulating base to prevent wall temperature from affecting sensor performance. SMOKE EVACUATION Wnere required by code, Landlord er loc jurisdiction provide smoke evacuation system requir ed. Provide a complete sequence of operation and wiring WINZI_.ER_IELLY C O N S U L . , N G E N G I w r e n s 495 TESCONI CIRCLE, SANTA ROSA, CA 95401 PH (7071 523 -1010 P.O. BOX 6798, SANTA ROSA, CA 95406 FAX (707) 527 -8679 diagram on plans. 3.04 DUCT SMOKE DETECTORS A. Provide and install, where required by code, Honeywell TC80D, or gquai ionization type smoke detector.:. with ON and ALARM indicating lights, relay, and adjustable sensitivity. State Fire Marshal approval No. 3241- 1130; 102. B. Provide cunt cts to interface with building fire alarm system and/or fire smoke. dampers. Line voltage wiring shall be by Electrical Dieisioa. PART 4 - SYSTEM BALANCING 4.01 SCOPE A. Work Included: The work under this Section shall include the complete adjustment and balancing of the mechanical systems and submittal of a report. B. The work shall be done by independent AABC or NEBB Testing and Balancing contractor. C. All work shall be done under the direct supervision of a Certified testing and balancing engineer. 4.02 EXECUTION The following ests measurements and adjustments shall be performed as a as and a,repport including all specified information shall be submitted to the GAP. A. Test and verify proper operation of all existing heating, cooling, and ventilation equipment. B. Test and adjust foes as required for complete air balance and record motor amperes and static pressure across fans. Pitot tube traverses' shall be made and results recorded . for all trunk ducts and at each fan when required to verify operation of systems. C. Test adjust and record the CFM of each air outlet and inlet to within plus or minus 10% of that required on the Mark final volume damper positions. D. Adjust all abode registers, grilles and diffusers to minimize drafts in occupied areas. E. Test and record compressor motor amperes and voltage under full load conditions. F. Test, adjust, and.record outdoor air CFM for each AC unit. G. Test and record outdoor air temperatures and temperatures entering and leaving cooling and heating coils. H. I. Verify the operation of each coil by recording the entering and leaving air temperatures and water temperatures where applicable at full cooling and full heating. J. Test, verify and record the operation of the interlock wiring to the Mechanical Systems. K. Test, verify and record the operation of each smoke detector in the Mechanical Systems. L. Test and verify proper operation of smoke evacuation equipment and controls if required. SECTION 15100 PLUMBING PART 1 - GENERAL 1.01 SCOPE OF WORK A. Installation of complete plumbing system including all piping plumbing fixtures, drains, and water heater os indicated on the drawings. Thermal insulation of plumbing doing systems. C. Any special work specified or sheen. D. Plumbing Contractor shall arrange for on independent drainage piping inspection and clearing service to provide a video i pection of existin sanitary clearing drain piping n shall be inspected the new Old Navy space. Pipes shol ected p from the Old Navy apace to point of connection to common mains and shall be cleaned free and clear of any obstructions. E. Contractor shall provide a written report; of the inspection with certification that drain lines are free and clear of any obstructions. Submit report to the GAP. for review prior to installation of any new piping or plumbing fixtures. 1.02 MATERIAL AND EQUIPMENT SUBMITTALS REV: DATE:. ISSUE FOR 7/8/98 PERMIT BY: DBR C. galvanized steel pipe with threaded cost iron drainage pattern fittings, or DWV copper tubing, copper or bronze sweat solder fittings, , 50/50 non -lead solder. Hot and Cold Water: 1. All sizes in building above grade shall by Type L hard copper tubing with wrought copper sweat solder fittings. Joints shall be 95/5 lead free solder. 2. All sizes below grade under floor slabs shall be Type K copper tubing ith silver soldered pints (15% minimum silver - content). Provide I. P.S.. Brass nipples of connections to fixtures, hose • bibbs and equipment. D. Gas Piping: 1. All sizes above grade, inside and outside building shall be Schedule 40 black steel pipe with 150 lb. black malleable threaded fittings. 2 . All s ti es abo ag node ou ts ide t h e buildin shall be readed Sch 40 g a ve lvanized s te el pipe with TOO Ib. th fittings. Gas shut -off cocks shall be provided at all equipment and shall be Crane - #298, or equal, for 3y�, and smaller or Nordstrom Fig. 142-143, or equal, for 1 and larger. 2.02 STERILIZATION OF WATER PIPING A.' The water supply and distribution system shall be sterilized with chlorine in solution in accordance with the American Water' Works Association Publication C -601- 1954 and local ordinances. B. All work and certification of performance shall be done by approved applicators: or qualified personnel with chemical and laboratory experience. Submit a certificate of sterilization. 2.03 ' PIPING TESTS A. All piping systems including valves and accessories shall be tested as follows. Tess pressures shall be maintained with no leaks for duration s specified. Soil, waste, vent and rainwater - fill with water to 10 ft. above the highest fixture. Tight for 8 hours. 2. Hot and cold water - 150 psig hydrostatic. Tight for 4 hours. 3. Gas piping - 60 prig air pressure. Tight for 4 hours. 2.04 PIPING INSULATION Test and record entering and leaving wet bulb temperatures at each cooling coil. A. Domestic hot water and hot water return piping shall be insulated with Owens-Corning Fiberglass or equivalent, heavy density, one piece, with ASJ jacket with self seating lap. Fittings shall be insulated and covered with 2.05 HOSE BIBBS B. C. A. Install a Chicago #293, 112" polished chrome plated, removable handle with E27 vacuum breaker, or equal, in each toilet room. Where winter desi 9 temperature is above 30 F, install a Chicago #13T, 1 with E27 vacuum breaker and removable Tee handle roug brass, or equal, every 75 feet on exterior perimeter walls. Where the winter design temperature in below 30 F, install with locking vandal- resistant cover, or J.R. Smith equa, every 75 feet on exterior perimeter walls. 2.06 TRAP PRIMERS Provide PPP Inc. Prime -Rite, or equal, trap primers for all floor drains. Provide shut-off valve and access panel as required. AIR CHAMBERS Provide Nibco „Fig.. 620, Sioux Chief Model 620, or equivalent 18 high vertical air chambers of size equal to local connection schedule size at all domestic' water connections to fixtures and equipment that are not specified to have shock absorbers. 2.08 SHOCK ABSORBERS A. Zurn series Z -1700 "Shoktroi ", or equal, stainless steel bellows type shock absorber at all individual flush valves or other automatic valves. B. Batteries of valves may be served by, a single unit sized in accordance with the manufacturers recommendations. C. Install with gate shutoff valve and access door. A. Submit descriptive information on all material and 2.09 equipment to the GAP prior to installation. B. Submit complete plumbing drawings to the GAP including piping layout sizing, isometrics and details. C. Plumbing Contractor to field verify exact location and size of sanitary sewer. PART 2 MATERIALS AND EXECUTION 2.01 PIPING A. Piping materials shall be as specified below for the services, locations and sizes called for except that other materials shall be provided; where specifically noted on the drawings or elsewhere in the Specifications. B. Soil, Waste, Vent and Rainwater: 1. All ron sizes pipe above and fit gr ti ad ngs, e antar d below grade: "No -Hub" cast i 2. 2 -1/2" & smaller above grade may be Schedule 40 1 Zeston or equivalent premolded fitting covers • a Zurn Z -1300 encased, non- freeze wall hydrant, complete ;;FLOW PREVENTORS A. Watts 009 -QT -S or equal, reduced pressure zone type with strainer. Install backflow preventors and vacuum breakers where required by code or where back siphoning' might occur to contaminate water lines. 2.10 CLEANOUTS A. Zurn as follows, other manufacturer where specifically noted, J.R. Smith, or equal. All cleanouts shall be lead seal type with cast bronze plug Cleanouts in waterproofed floors shall have hashing flange and membrane clamp. Floor: ZN- 1400 -NH, polished nickel bronze cover. Accessible: ZARB -1470, cast iron or steel pipe. Nibco Fig. 816 or 817, copper tubing. Wall: ZANB -1468, polished chrome plated cover, cast iron or steel pipe. Nibco Fig. 818 or 817 with 6 "x6" Zurn Z -1460, PROJECT LOCATION: TITLE: SPECIFICATIONS DRAWN: MMN 2.10 DRAINS A. Zurn as follows, Zurn, or equal. ED -1 Floor Drain: 2 -415 Type "B" polished nickel bronze strainer, 2 size or as shown with' trap primer connection. IWR -1 Igdirect Waste Receptor: Z -1025, fixed air gap fitting, 2 s trap and trap primer connection. Provide wall access with panel where Installed Inside wall. B. Drains in waterproofed floors shall have flashing flange and membrane clomp. 2.11 FIXTURES A. The quantity. and location of fixtures hall be taken from the Architectural and cat Plumbing drawin B. Provide all standard trim normally furnished for fixtures, no substitutions accepted. C. All enamel shall be acid resisting. D. Submit cuts on all fixtures, no substitutions accepted. E. Provide air chambers or shock absorbers as specified. F. Provide 1/4" steel backing plates, 36" wide by �- 12" high Ir minimum ige secured to a minimum of 3 studs by elding or with 1/4 bolts for all wall hung fixtures for which other means of support is not specified. G. Provide backing plate or blocking for attachment of mop sink faucet brace. H. Water piping at stop valves and flush valves shall be rigidly secured to blocking. Drop -ear elbows shall be used where suitable. I. Provide stops for all fixtures:„ Exposed, at lavatories and similar fixtures Brass Craft Speedway chrome plated loose key, concealed - Chicago #17/0 or #1771 LV as required. J. Fixtures shall be as follows: OPTION A (Preferred) WC -1 WATER CLOSET: Floor mounted flush valve, elongated bowl, siphon jet, vitreous china complete with bolt caps, 3.5 gallon flush. FIXTURE:, Kohler„ Mode: "Wellcome; K -425Q, American Standard Model: 'Madera 2221.18 or Eljer 'Tri -san 111 -0235 SEAT: Church #9440KC open front, 3150/3155 concealed choir and hinge posts. FLUSH VALVE: Zurn Model Z -6000 WC -2 WATER CLOSET (Handicapped): Fixtures shall be ADA compliant floor mounted, flush valve, elongated bowl, siphon jet, height to meet ADA requirements, vitreous china complete with bolt caps. 3.5 gallon hush. FIXTURE: Kohler yodel: "Highcrest" K -4271, finericgp Standard Model: "Cadet 18 EL 3.0" 9468.018 or Eljer 'Hi -San 111 -3244. SEAT: Church #9400 KC open front; 3150/3155 concealed chair and hinge posts. FLUSH VALVE: Zurn Model Z -6000 OPTION B (Where variance cannot be obtained for Option A) WC -1 WATER CLOSET: Floor mounted flush valve, elongated bowl, siphon jet, vitreous china complete with bolt caps, 1.6 gallon 05 Zurn Model Z- 6000 -WS li'TION Q (Where domestic water supply pipe is smaller than 1 -1 d ig t er ) WC -1 W ' R CLOSET: or mounted, pressure assisted flush, gon bowl, vitreous china complete with bo 1.6 gallon has FIXTURE; Kohler M Model: Cadet 2292 on jet caps, "Wellworth" K -3458: American Standard SEAT: Church #9400KC op front, 0/3155 concealed chair and hinge posts. WC -2 (handicapped): Fixture all .- ADA compliant floor mounted, pressure assisted Iphon jet sh, elongated bowl, vitreous china , complet= with bowl caps, 6 gallon flush. FIXTURC: Kohler .:el "Highline" K -3544 or ' -.ericon Standard . Model Cadet ::.100. SEAT: Ch h #9400KC open front, 3150/3155 concea :. chair and hinge p U URINAL: Fixtures shall be ADA compliant, siphon jet, hei•.t meet ADA requirements, vitreous china, 1.0 gallon flush. polished chrome plated bronze wall plate & frame, copper tubing. FIXTURE: Kohler yodel: "Wellcome Lite" K -4350, American Standard Model: Madera" 2234.015 or Eljer Model: Preserver" 111 -4805. SEAT: Church #9400KC open front, 3150/3155 concealed chair and hinge posts. FLUSH VALVE: Zurn Model Z- 6000 -WS Fixtures shall be ADA compliant 2 WATER CLOSET (Handicapped): Ixt liant A. h p Floor mounted, flush valve, elongated bowl, siphon jet, height to meet ADA requirements; vitreous china complete' with bolt caps, 1.6 gallon flush. FIXTURE: Kohler „model "Hii hcliff„Lite" K -4368, American Standard Model: Cadet 18 EL 1.6 3043.102 or Eljer Model: Preserver 17 1.6 gallon 111 -4815. SEAT: Church #9400 KC open front; 3150/3155 concealed choir and hinge posts. FLUSH VALVE: PARKWAY SUPERCENTER TU K WI LA, WA SCALE: NONE CHECKED: DBR STORE NUMBER: 5359 FILE: FIT •. Mo Allbrook FLUSH VALVE: Zurn - C urn -1221 r Model: "Dexter' K- 5016 -T or Am-'.:- " andard LV -1 LAVATORY: Fixtures shall be ADA compliant, wall mounted, self - draining deck, back and side splash shields 4" centers for faucet installation, vitreous china. install insulation on P- trap and hot water stop and supply. FIXTURE:„ Kohler Model: "Kingston" K -2005, „or .American Standard Model: Lucerne" 0355.027, or Eljer Model: Delwyn 051 -2541. FAUCET: Delta Model 501 -WF or Kohler Model K-15598. CARRIER: Zurn -1231 INSULATION: Prowrap Model If W2000 Insulation Kit or approved equal. P K: Corner mop sink, enam cast iron with vinyl coated MS -1 ri g 3 outlet with perforated eled strainer. FIXTURE:„ Kohler Model: "Whitby" K- 6710 „or American Standgrd Model: Florwell' 7741.00 or Eller Model: Custodial Floor Sink 242 -0050. FAUCET: Kohler Model K -8904 oc Chicago Model 540- LD- 897S -WXF, 3/4 hose thread outlet, pail hook with wall bracket, vacuum breaker spout. ELECTRIC WATER COOLER: ADA compliant, HFC -134A (NON -CFC) refrigerant, lead free, satin stainless steel. ELECTRIC WATER HEATER: Fixture shall be mounted in janitor's closet above mop sink. Fixture complete with drain plug, temperature and pressure relief, single heating element, and expansion tank. SECTION 15160 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.01 SCOPE OF WORK A. The work includes furnishing and installing overhead automatic, wet pipe fire sprinkler system for the complete demised space as indicated on the drawings. Sprinkle all areas above and below suspended ceilings and where required by the National Fire Protection Association, the local fire and building departments and the Landlord. 1.02 REGULATIONS A. In addition to the special requirements of the local fire and building departments and the Landlord requirements, the requirements of Pamphlet #13, Sprinkler Systems of the National Fire Protection Association. B. Fire protec(UL)) tio e uipment shall be Underwriters Laboratories listed. C. The system shall be installed by a cbntractor licensed to perform this type of work. 1.03 MATERIAL AND EQUIPMENT SUBMITTAL A. Submit descriptive information on all material and equipment. 1.04 SHOP DRAWINGS A. Before the sprinkler contractor begins the installation, the GAP shall be provided with 3 complete sets of approved shop drawings. The shop drawings shall include details of the sprinkler system including sections, light fixtures, interior ducts and other nterior work affecting the sprinkler system layout and the locations of supply connections, control valves, and other appurtenances to.be used. B. S drawings reviewed and approved by the local fire hop and bu shall departments be and the ap Lan PART 2 - MATERIALS & EXECUTION 2.01 SPRINKLER HEADS AND EQUIPMENT 2.02 A. 2.03 A. All piping in finished rooms shall be concealed unless specifically noted to be exposed. Provide a printed sheet, protected by glass or a transparent plastic cover, with brief instructions about all necessary aspects of the sprinkler system controls, emergency procedures, etc. Coordinate location with the GAP. 2.04 TESTS AND ADJUSTMENTS . Sprinkler system shall be tested as required by NFPA Pamphlet 13. RECEIVED B. Coordinate any Landfdrd special testing requirements. °FTUKwRA u 1998 PERMIT CENTER B. A. J: \98 \229528 \CAD Sprinkler heads shall be Reliable Automatic Sprinkler Company as follows, or equal: 1. Pendent: Model G4 with natural brass finish head. 2. Upright: , Model G with brass head. Instoll in all open areas with no ceiling where indicated. 3. Recessed: Model G, chrome head with white escutcheon. PIPING Install in suspended tile ceilings where indicated. 4. Concealed: Model G eil 1, iwnith where white in cove dicar te plate . Install in gypsum board cg Piping shall be Schedule 40 black steel pipe with 175 psi sprinkler or 125 psi SOP black cast iron or malleable iron flttings. INSTALLATION SHEET NUMBER: M1.0 PACKAGED GAS /ELECTRIC UNIT SCHEDULE MARK MFGR MODEL CFM MINIMUM OA CFM ESP UOTOR HP COOLING (MBH) HEATING (MBH) ELECTRICAL WEIGHT (LBS) REMARKS SENS TOTAL INPUT OUTPUT VOLTS PHASE MCA /MOCP RTU -1 CARRIER 48HJD017 7530 1190 1.0 5.0 161.9 190.5 275 222 460 3 44/50 2360 - RTU -2 CARRIER 48JID017 7520 1120 1.0 5.0 161.9 190.5` 275 222 - 460 3 44/50 2360 - RTU -3 CARRIER 48HJD017 7490 1090 1.0 5.0 161.9 190.5 275 222 460 3 44/50 2360 - RTU -4 CARRIER 48HJDO17 7490 1090 1.0 5.0 161.9 190.5 275 222 460 3 44/50 2360 - EXHAUST FAN SCHEDULE MARK MFGR MODEL CFM RPM SP ELECTRICAL SON ES OP. WT (LBS) ACCESSORIES HP VOLT PH HZ EF-1 GREENHECK GB -80 370 1110 0.375 1/4 120 1 60 5.4 30 W /BACKDRAFT DAMPER ROOF CURB MARK WSR -1 CD -1 CD -2 CG -1 CG -2 WRG -1 AT MID -POINT VOLUME DAMPER GAP M ANU F. TITUS KRUEGER METAL -AIR TITUS KRUEGER METAL- AIR TITUS KRUEGER METAL -AIR TITUS KRUEGER METAL- AIR TITUS KRUEGER METAL -AIR TITUS MODEL CEILING 1/4" BOLT OR #10 S.M. SCREW, EACH HANGER AIR TERMINAL SCHEDULE 300RL 880H H4004D PSS TYPE 1 1100 FRAME 22 7600 -1 PSS TYPE 3 1100 FRAME 23 7600 -6 PAR (DUCTED) PXP (PLENUM) 1190 FRAME 23 7600 -6 (DUCTED) SPRTB (PLENUM) PAR (DUCTED) PXP (PLENUM) 1190 FRAME 22 7600 -6 (DUCTED) SPRTB (PLENUM) 350RL KRUEGER 580H METAL -AIR H4002R -7 DUCTED AIR TF DETAIL I NTS Gap, Inc. Corporate Architecture 900 Cherry Avenue San Bruno, CA 94066 -3010 (650) 952 -4400 DESCRIPTION NOTE: 4 -WAY DISCHARGE PATTERN UNLESS SHOWN OTHERWISE BID ALTERNATE DEDUCT #1 MECHANICAL CONTRACTOR TO PROVIDE AN ALTERNATE DEDUCT FOR THE FOLLOWING. WALL SUPPLY REGISR 3/4" SPACING DOUBLE DEFLECTION, RONT BLADE HORIZONTAL, W /OBD CEILING SUPPLY DIFFWER 24 "x24" PERFORATED FACE A STEEL CONSTRUCTION BLACI :INTERIOR W /OBD FRAME TO SUIT CEILG CEILING SUPPLY DIFFER 12 "x12" PERFORATED FACE A STEEL CONSTRUCTION BLACK INTERIOR W /OBD FRAME TO SUIT CELLS' CEILING RETURN GRIIE 24 "x24" PERFORATED FACE A. STEEL CONSTRUCTION BLAC INTERIOR W /OBD FRAME TO SUIT CEILG CEILING RETURN GRLE 12 "x12" PERFORATED FACE ._L STEEL CONSTRUCTION BLAC INTERIOR W /OBD FRAME TO SUIT CEING WALL RETURN GRILL 3/4" SPACING BLADE HORIZONTAL NOTE TO MECHANICAL CONTRACTOR CARRIER EQUIPMENT WILL BE FURNISHED BY GAP, INC. WITHIN THE FIRST WEEK OF CONSTRCTION. THE MECHANICAL CONTRACTOR SHALL FAX THE NAME, TELEPHONE AND FAX NUMBER OF THE PERSON RESPONSIBLE FOR SHEDULING AND RECEIVING THE HVAC EQUIPMENT AND ACCESSORIES ALONG PATH THE REQUIRED DELIVERY DATE, ADDRESS, AND NY SPECIAL HANDLING INSTRUCTIONS TO: E.B. WARD ATTN.: RICHARD FRENZEL PHONE: 650- 873 -1660 FAX: 350 -873 -6829 ALLOW A MINIMUM OF TWO WEEKS AFTER CONSTRUCTION STARTS FOR DELIVERY OF THE EQIPMENT UNLESS SPECIAL ARRANGEMENTS. ARE MADE PRIOR TO THE START OF CONSTRUCTION. - UPON DELIVERY THE MECHANICAL CONTRACTOR SHALL BE ULTIMATELY RESPONSIBLE FOR i1_': EQUIPMENT AND ACCESSORIES, INCLUDING THEIR UNLOADING, STORAGE, INSTALLATION, AND START UP ON THE PROJECT. THE MECHANICAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK HE PROVIDEDUNDER HIS CONTRACT. THE MECHANICAL CONTRACTOR SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY WORK, AATERIALS, OR ADDITIONAL EQUIPMENT. HE PROVIDED WHICH MAY BE DISCOVERED DEFECTIVE WITHIN A 12 MONTH - PERIOD FROM THE D:TE OF ACCEPTANCE (IN WRITING) BY GAP, INC. GAP; INC. SHALL PROVIDE A COMPLETE 12 MONTH EQUIPMENT AND MAINTENANCE WARRANT' - FOR ALL PARTS AND EQUIPMENT PROVIDED BY GAP, INC. AND. GAP, INC. VENDORS AFTER FINAL INSPECTIONS, START —UP, AND AIR BALANCE REPORTS HAVE BEEN APPROVED. THE MECHANICAL CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONEYS SHOULD BE INCLUDED IN THE BID. 1. HVAC EQUIPMENT IDENTIFIED ON DRAWING SHEETS M2.1, M2.2 AND M2.3 AS RTU -1, RTU -2, AC -1, AND FC-1 TO BE FURNISHED BY GAP AND INSTALLED BY THE MECHANICAL CONTRACTOR. 2. THE MECHANICAL CONTRACTOR SHALL INCLUDE ALL LABOR, ADDITIONAL MATERIALS, EQURMENT, SERVICES, TOOLS, TRANSPORTATION, AND FACILITIES NECESSARY FOR COMPLETE MECHANICAL INSTALLATION OF THE ABOVE LISTED MECHANICAL EQUIPMENT. 3. INSTALLATION SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, - APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS. 4. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SEE DRAWINGS FOR ADDITIONAL DETAILS. 5. ALL STORE COMFORT AND EQUIPMENT ISSUES NOT RELATED TO THE INSTALLATION WILL BE RESOLVED BY GAP STORE MAINTENANCE DEPARTMENT UPON ACCEPTANCE OF THE STORE AT THE END OF CONSTRUCTION. - FIRE /SMOKE DAMPER ACTUATORS BY MECH (IF REQUIRED) SUPPORT FLEX .— 2" WIDE 26 GA. GALV S.M. STRAP FLEX DUCT CONNECTOR ' (MAX 5' LONG) "Ii 1 -1/2 DUCT DIAMETER, 111. CURVED BLADE CORE - MIN _A _ ( -PERFORATED FACE PLATE �- SEISMIC SUPPORT WEE (2 REQUIRED PER DIFFUSER) HOT (R) LEG OF -\\ THERMOSTAT (LOW VOLTAGE) WINZLER IcELZY C S U N G I N E E R S -- 495 TESCONI CIRCLE, SANTA ROSA. CA 95401 - PH (707) 523 - 1010 P.O. BOX 6798, SANTA - ROSA, - CA 95406 FAX (707) 527 -8679 FINISH #26 WHITE STANDARD #49 WHITE STANDARD PAINTED OFF WHITE #26 WHITE STANDARD - #49 WHITE STANDARD WHITE #26 WHITE ;STANDARD. #490 WHITE STANDARD PAINTED OFF ,WHITE 26 WHITE STANDARD #490 WHITE STANDARD PAINTED OFF WHITE #26 WHITE STANDARD 490 WHITE STANDARD OFF WHITE #26 WHITE STANDARD #49 WHITE STANDARD PAINTED OFF WHITE THERMOSTATS W/ LOCKING COVERS IN MANAGERS OFFICE ./ TYPICAL CONTROL DIAGRAM REV:.. DATE:., ISSUE FOR: - BY: SMOKE DETECTOR (SUPPLY DUCT) REMOTE SENSOR TYPICAL . 7/8/98 PERMIT:. DBR- HVAC UNIT TWO UNE 120V BY ELECTRICAL ONE LINE ABBREVIATION DESCRIPTION CER - CEILING EXHAUST OR RETURN REGISTER S T_ I1. CD CEILING DIFFUSER - ARROWS INDICATE THROW 12x12 WSR SIZE -WALL SUPPLY REGISTER 150 NC CFM -NEAR CEILING NF NEAR FLOOR 8' -0" ELEVATION TO BOTTOM OF OUTLET WER WALL - EXHAUST OR RETURN REGISTER (CTE) CONNECT TO EXISTING WEG WALL .EXHAUST OR RETURN GRILLE SAD SEE ARCHITECTURAL DETAIL SA SUPPLY AIR DUCT SECTION IJS IN JOIST SPACE RAD RETURN AIR DAMPER EA /RA EXHAUST OR RETURN AIR DUCT SECTION DTR DUCT THROUGH ROOF OA OUTSIDE AIR DUCT SECTION - EAD EXHAUST AIR DAMPER SQUARE ELBOW WITH DUCT TURNS DAD OUTSIDE AIR DAMPER (N) NEW WORK NIMD WORK NOT IN MECHANICAL DIVISION RADIUS ELBOW NTS NOT TO SCALE DN DOWN OAT OUTSIDE AIR TEMPERATURE PROPORTIONAL TAKEOFF - T SPECIFIES SIZE OF BRANCH TAKEOFF IAT INDOOR AIR TEMPERATURE POC POINT OF CONNECTION AIR EXTRACTOR V.I.F VERIFY IN FIELD AE FLEX - FLEXIBLE DUCT CONNECTION PROJECT - LOCATION: JLq U TUKWILA, WA DRAWN: - MMN DUCTWORK LEGEND MANUAL VOLUME DAMPER FIRE DAMPER FIRE SMOKE DAMPER SOUND LINED DUCT THERMOSTAT, SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT TEMPERATURE SENSOR (E) EXISTING DUCT, EQUIPMENT, ETC. PARKWAY SUPERCENTER 5359 TITLE: - MECHANICAL DETAILS, SCHEDULES, & LEGEND SCALE: AS NOTED FILE: STORE NUMBER: CHECKED: DBR J: \98 \229528 \CAD ABBREVIATION DESCRIPTION AD ACCESS DOOR AFF ABOVE FINISHED FLOOR, AP ACCESS PANEL BDD BACKDRAFT DAMPER IFC IN FURRED CEILING SPACE REVIEW SPECIFICATIONS ON SHEET MP1.0, SECTION 15200, PART 4 FOR DATA REQUIRED IN TEST & BALANCE REPORTS. NOTE: .COOLING CAPACITY SELECTED AT 92.5 F ENTERING CONDENSER, 76.4 DB /62.2WB ENTERING EVAPORATOR AND AIRFLOW INDICATED. ACCESSORIES: LOW AMBIENT START KIT TIME GUARD II, ROOF CURB, ECONOMIZER W /POWER RELIEF, 2" FILTERS. SHEET NUMBER: M1.1 RECEIVED C1TY OF TUKWIL n 1 199 E PERMIT C£NTEF GAP Gap, Inc. Corporate Architecture 900 Cherry Avenue San Bruno, CA 94066-3010 (650) 952-4400 (7) 18x10 WSR -1 640 r 160 240 200 160 j ft r- , 20x20 72x16 RETURN DUCT ; 4t: .(LED) ' 16x72 RADN • ' ' II THRU ROOF 260 -1 ,, (LINEE4=- - : -- 1 ' •', . • r 1 • - . :' ' - 1, . , : : , - -- - ,240 ! I •,." 200 200 160 - • NI a V TEN 24x2 r 1 , SM f • • I E, I 20x68 SA. ON • THRU ROOF (LINED) , • WRG-1 1 •;14-00 • • . 72x16IRETURN DUCT (LINED t 1672 RA N „ THRU RD,QF (LINED) ON: ROOF SMOKE DETECTOR w 26x20 RTU -2 1\410 -011i) 20x68 SA DN THRU ROOF (LINED) SMOKE DETECTOR ON ROOF , • • i ., 20x30 200 NIVENTZT c.c-; x KELLY CONSULT' NG ENGI NEERS 495 TESCONI CIRCLE, SAN, ROSA, CA 954oi PH (707) 523-1010 P O. BOX 6798, SANTA ROSA, CA 95406 FAX (707) 527-8679 (7) 20x6 WSR -1 430 , , • j , L • 1 r IL J , r 1 ■••• I I H ; _ -• F — , : H (4)48x12 WRGH 1600 REV: DATE: ISSUE FOR: 7/8/98 PERMIT 14 18x10 WSR-1 535 T I • K K K! EP] • • K K • K 11 1 i • _ _ • [2D, DK • pp ! k • E , , ,.e; 1 20x68 SA ON THRU ROOF (LINED) (4)48x12 WRG 1600 • .„ RETURN DUCT. (LIP - • 16x72 RA DN •••,- TRRU, ROOF - tONED) .41111 ON ROOF `41fir DETECTOR-, HVAC PLAN[. PROJECT LOCATION: DRAWN: MMN 0 0 11E_SD 7 ----160 H 80 ,____, 777 ' - 1 —200 1 ■ 260 ',... ..... - -- ' 7' ■,-- 1 14 1 .„i '• 44x20 , 28x20 —20x20 ' - - 160 TITLE. HVAC PLAN (16) 18x10 WSR -1 470 ID 80 CG-1 130 60 CD-2 • I 1 130 •,/,..t-14120 F- CD-2 80 H 2 60 CG-2 - (6 20x68 SA DN THRU ROOF (1JNED)_ 1 „, , . --- `.. . ',1 ' -..--240 , ii,-- ------- - , ; II !,..1 ,, :•-; !-- 260 I . I ! !,•;!: ; 400 (4) 12x16 WSR-,1 1 2901 TC -r• 11 iL- i40 L2160 lowfisie ars. 'F ROOF 5OKEDETECTOn f rf 20x30 ; (5) 20x6 WSR -1 240 , 200 60 CD-2 100 160-- 80 120r- 1 •L 1 I 60 CG-2 A IL 1 ' 50 48x12 ARC 1 lei ct, , RETURN 72x16 ,; i RA D THRU ROOF 50x16 (LINED) I (4) 12x8 WSR -1 350 L. - 500 PARKWAY SUPERCENTER 5359 SCALE: 1 /8” =1'-0” FILE: THERMOSTAT WITH LOCKABLE COVERS IN MANAGER'S OFFICE. MOUNT 54" AFF TYP 160 CHECKED: D8R J: \98 \229528 \CAD i00- 160 10X10 DN THRU ROOF 1340 _ ON ROOF I I 1'. (2) 48x24 WRG-1 '•• • i 2500 I (5) 18x10 WSR-1 STORE NUMBER: NORTH SHEET NUMBER: , TUKWILA, WA , M2.1 c4g4CF, ,99E, PERM: ',DENTai