Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M98-0174 - SOUTHCENTER MALL - RAINFOREST CAFE
Rt ri•ore5f Caere— i 61? City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 . Permit No: M98 -0174 Type: B -MECH Category: NRES Address: 290 SOUTHCENTER MALL Location: Parcel #: 262304 -9004 Contractor License No: PCLCOSI099NW TENANT OWNER CONTACT CONTRACTOR **** k**************************** k*********** *** * * * * * * *** * * * * * * ** * ** *** * * ** Permit Description: MECHANICAL'UNITS /ROOFTOP MOUNTED, EQUIPMENT FOR NEW RESTAURANT. UMC Edition: 1997 Valuation:.. * * * * * * * * * ** * * ** ** _T1 CALL Permit Cen Authorize • Signature Date I hereby. certify. that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this mark will be complied with, whether specified herein or not. The grantingof this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this buil 'ng perms . Signature: Print Name: RAINFOREST CAFE 290 SOUTHCENTER MALL, TUKWILA WA 98188 RICHARD E JACOBS GROUP INC Phone: 216 871 -4800 25425 CENTER RIDGE RD, CLEVELAND OH 44145 TODD HESSON Phone: 602 -381 -3201 CUNNINGHAM HAMILTON AUITER, 2828 N CENTRAL AV #1110, PHOENIX AZ P C L CONSTRUCTION SRVC INC Phone: 425- 454 -8020 PO BOX 52868, BELLEVUE WA 98015 *************************** * * * * * * * * * * * * * * * * * *' * *** * * * * * ** MECHANICAL PERMIT Total Permit Fee: Date: Status: ISSUED Issued: 01/05/1999 Expires: 07/04/1999 (206) 431-3670 500,, 000.00 474.00 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or ;i:f the :work is suspended or abandoned for a period of 180 days-from the last inspection. Pp Name/Tenant: f�i IN r�eF CAF i✓ u j C r�r��- Li-- Description of work to be done: dzr-- U pt f 5 - G / [ ,s Sy rt 9 11 ht �(2U V. : of Construction: '..'„ Don . . Si d Address: ty State /Zip: ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof Demolition ❑ Fence - Mechanical ❑ Manufactured Housing - Replacement only Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting a rc plum r Propert wner• T rllr iCt Zl) IC. J a)3s ti FOUP I N1c . Phone: ( 811 — I�soa Street A ddress , City State /zip: ° . ' ('6 I .� F•sz . Ru=G E , (?,0-P i) C t .\! (Avs 0 (iI 4q (+ _ Fax #: ( I 0 SGP - 236g r(7,-) .r qq0 —461— .zv C Contact P rson: Street Add City State /Zi ��, fv�lYz�tr- rrc� �� �(�D�,JI� �; Fax #: ` �IPCO)r).b> q? > rG trac r: 1'� r ,� n1 STl2l c.� 10 � �\1 t c- , n.l; 3 ,i .S 7, m t I Nic • City State /Zip: Fl - r6i , m Ss4.6 1 Phone ( Cold -) c NS' . GOC6 Fax #: afzp) RE6 - I G9 -- cf Street Address: 3') Jt rchitect: 1nlll\S l tLroNI Qv. (Tc- lz P Phone: , noct) a(i)G.- -fi,5 -- .q treet Address: , y State /Zip: Oak_ S, . ' ak J _ , AN 0 acD t 1 , _ • 1 ► � 1 ' Fax #: .0, a ( • gi1,F1STe��j E - 5GX1 — '-e 50 CtD.) ( — l (c;3 Street Address: (q 00 �t City State /Zip: • X111l� b�- Fax #: �O .-) plc R a ,IL MISCELLANEOUS PERMIT RE EW AND APPROVA REQUESTED: (TO BE FILLE ' OUT BY APPLICANT) Description of work to be done: dzr-- U pt f 5 - G / [ ,s Sy rt 9 11 ht �(2U / it I 7 A/ vE/ "C' PY a r/ vt uC ` ,4/ (, tiq 514.4 Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and stora.e location on se•arate 8 1/2 X 11 •a•er indicatin • • uantfties & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof Demolition ❑ Fence - Mechanical ❑ Manufactured Housing - Replacement only Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY S ER BILLINGS TO: Name: C1- .)t IZ ∎fT10rI 5rtexil C,C.6 kic . I Phone: 0.21>-) j_ 9.)00 Address: q 7 30 1 S A 0J\ so u e rtt Pfd E1 1-b t fl f - s , Water Sewer f 0 Metro 0 Standby Date applicatio accepte : Miscellaneous Permit Application MISCPMT.DOC 7/11/96 CITY OF f 'IKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. r APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelizatlon /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # IT Water Meter /Permanent # Water Meter Temp # ❑ Miscellaneous Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Size(s): Est. quantity: gal Schedule• ❑ Moving Oversized Load /Hauling WATER METER DEPOSIT /REFUND BILLING: Name: ?C\-- C L,1 I6N RBI Address: () fc Phone: Q( ) Et1 c ? c ity /State/ 'p: OM Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date applica expire : App(Ica qty: (Initials) BUILDING O E -; oR J�U b- ED AGENT: Signature: ' 1 I Date: Print name r . • • f - • • 40 e if P p�6.157t da17ar? Sho: e ,I,� o 0 l. ` ,-. c F #: '11 (�� t. v. q. . ' Address: ..._,::_x) ' ti ll'` :�I K fr: -7 ; 3 0 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist No: M - El Antennas /Satellite Dishes • Submit checklist No: M -1 0 Awnings /Canopies - No signage Commercial Tenant Improvement Permit ri Bulkhead/Dock Submit checklist No: M -10 ri Commercial Reroof Submit checklist No: M -6 rEl Demolition Submit checklist. No: M -3, M -3a El Fences - Over 6 feet in Height Submit checklist No: M -9 71 Land Altering/Grading /Preloads Submit checklist No: M - 2 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 Mechanical (Residential & Commercial) Submit checklist No. M - 8, Residential only - H -6, H - 16 Miscellaneous Public Works Permits Submit checklist No: H - 9 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M - 5 Moving Oversized Load /Hauling Submit checklist No: M - 5 Cl Parking Lots Submit checklist No: M -4 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist . No: M -6 El Retaining Walls - Over 4 feet in height Submit checklist No: M -1 Ei Temporary Facilities Submit checklist No: M - 7 Temporary Pedestrian Protection/Exit Systems Submit checklist No: M - 4 71 Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PE ' IT APPLICATIONS MUST BE SUBM ED WITH THE FOLLOWING: A ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT A STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) 0 Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,or, contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY HAT I HAV,EAD AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF P RJ RY BY T HH AWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 -�-« . Address: 2 90 SOUTHCENTER MALL Suite: Tenant: RAINFOREST CAFE Type: B-MECH Parcel #: 262304-9004 CITY OF TU{(WILA Permit No M98-0174 Status: ISSUED Applied: 09/11/1998 Issued: 01/05/1999 k*A.***A******A***Ak.A.AAk**kAA***Akl(**AAk*********k*A**** Permit. Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the Tu,kwila Building Division. 2. All permits, recQrd, plans shall be available at the jobs1te;:'-Pribf any con- struction. These:;:*ctibentsare to he main't0We'd,and avail- able until finanspect aPproVai is grant, 3. All constructin to be done in oOnformanCe;'Wi,th aWoved plans and r:eqiiirements Of the UniforM Bui1d)hg.,Cod997 Edition) ,eS'amende'd,., Uniform.MechanicaJCode 1 EAA and Washington State Energy Code, (1997 , 4. Electrical permits shall be'obtajned through State/Divi Of Labor and IncitistOes and alLetectricaM), work will be inspeotedby''that agency (248-6630. 5. Plumbing "004 :hall he obtained through the S'eattl.e—kin County Department of POblio Health.. Plumbing insOetted bY that agency, inCluding"'all gas piping;., 6. ValAdity of Perm)t, , The is4uance',Of;a:perOt or approyalotl: and. shall not be cut strUed to be a permit :for;:t5r an':appr/.Oval2Of any violation o c1- the provisions pg':the bullding crude or of , ,any other ordinance Of /the Tur Ld Iction No4ermit pre&umIng to, , give authority to'Oblate'or Oancel , otYth4 ‘• , cocWshali,,be;Nalid. 4 4 J I • ), • ..., ;.)) • ). ,? ) " ) • )'L) 1%) • " • ti-e; DEPARTMENTS: ?king Division ubli I O ks `7,0� TUES /THURS ROUTING: Approved El Approved with Conditions \PR•ROUTE.DOC 6/98 ?€IiKU &i�vL Co PLAN REi�IEW /ROUT SLIP ACTIVITY NUMBER: M98 -0174 DATE: 9 -11 -98 PROJECT NAME: RAINFOREST CAFE _IX_ Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After Permit Is Issued "(v Fire Prevention Planning Division Structure � q' -1H it/ Li Permit Coordinator t� DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 9 -15 -98 Complete a Incomplete ❑ Comments: Not Applicable Please Route ❑ No further Review Required Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 10 -13 -98 Approved El Approved with Conditions Not Approved (attach comments) Ei REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Not Approved (attach comments) E REVIEWERS INITIALS: DATE: /41-7A.is r- ec , ) A : �Z' C ,4 M -c- Date called: �- Special instructions: Date wa ted: // ' � -.7.4) ...- a.m. e?`99 p.m. Reques e : Q �/ Phone: INSPECTION NO, R eceipt 1,1 o: s y INSPECTION RECDli Retain a copy with permit Approved per applicable codes. COMMENT • Date: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Q6)431 -3670 Da ef Corrections required prior tg approval.,., E $47.00 REI SPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: • JJJJ l Sa..e..//,11--te _.- /�rK l7� ep LI / , T of In pec i n' 3 'Id '2') , sdip I1 a) Gi4)`11.Q / 7L/ (l l.//"Zf 1 -4-4 -- .. Gl i / 1 \ /� J/r� / p» S ,, ! C s r7 /4„44 L` C al-44 1-, 2I6 14h1 lti►.dit X7'4/ /�, 1'z'2�L2� ,-,-.9U- 5)L542lur ) 4.4.4 . , / � / `�Y7 c/` - Pro ct: -- S D T of In pec i n' 3 'Id r�js : m,/ e/ Date called: C , A , ., Special instructions: Date wanted: 4', / Cp. m. (% 'tom Requester: / (,441.,—, Phone:, , — 793 - 3//' n` CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 El Approved per applicable codes. (Corrections required prior to approval. Inspector: $47. , ' EINSPECTION• RE" IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: ti INSPECTION RECORD;L Retain a copy with perm M98 —017/ v (206)431 -3670 Date: l,7 i/ /:iq Proir: , Ai roP-6s7- Type of Inspection: 1.-- rArikt, Address: 90 Sc M 4 (-4...- Date called: Special instructions: .4* Date nte : ,... 1 Lo a.m. p.m. Reques . e.... Phone: INSPECTION RECOC Retain a copy with permit • • \:" COMMENTS: ,Q T /A.L rr,J - 1 S MO /4E. S H-vrDowl 1`e S Uk.. A-I.cr E-•t)A/ i7"5 (,- 8, © r( /ZE D4,44 t rr sr-5 a•t_ es. '/i /- Q%z 4 —77,7796 ri) 'kw e-g- g -x r1 -A-vsr e -rr e c oc,.. Date wanted: 6 - 05 -qq 0 64 rn— OG WA re ng- './it's (0 e k. or pv,4 r - p4-A, A-S I2gQ ✓bee 7 s 0 M 00 0 s v Pile -e ssr o 1..( .iv' .e c. cc . 1sr o ,- r J. e Pro t: A.r1Fv957 Typ Ins ct'ion: / — 17 ST.- Address: 240 5C M4 4 (....- Date called: Special instructions: Date wanted: 6 - 05 -qq a.m. p.m. Requester: Phone: INSPECTION RECOR Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 pproved per applicable codes. Corrections required prior to, approval. 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: ' O a f j , (/ 7 ' Inypect fri: �� "ps: e � � a o Date called: ''1 4a / / Special instructions. ill ,r-,,, 0 G 3U Date wanted: 4 / a.m. Requester: Phon /_.... 7 /6 INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 El Approved per applicable codes. COMMENTS: . �✓: .,r�rAis INSPECTION RECO Retain a copy with permit / /- rug S ia 4 ' ,Y _ �: Are,. .L / /1 ' Fief" • $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Receipt No: Date: PERMIT NO. (206)431 -3670 Corrections required prior to approval. Pr l `i/ '57 Type of Inspection: A7r90 - 5. 111 Date called: Special instructions: Date wante 6' / �� a.m. p.m. Request oi., Phone: INSPECTION NO. INSPECTION RECO Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 MIT O. v/ 01'W (206)43 3670 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: ( CT`7 tl C Pte.., A r( 7 v11rr0 11. : Inspec '77 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: COMMENTS: / 1 5, „, i ts a// A' 3l r ��/l 44 A. eO f C A / c 7)% `l..+/� , o0.. .4 "74 1 . . • ` m ! . 4,/-- �Ar'P1,/ 'T/� 1 �l /e4 (,vf.. Uf (.14.-7/1 „ -,�� ,, 0 45 a 4 - " (� _ C 4) w - , ,,,.,, �.zh. /Ze 4.go&--lam 1 . - , P - ' g,.6,/ m. 'A— r / s d - 2 6 Aie4 , -.) CY-Y 7/ .-/ fr [A/r P. 4 , Date wanted:, Q a.m�) 5" 4f4 -/ 6, Phon . �7 r b(p r 1 •9 3 7 3// 7 / . •• ! f , IT 1,71 /a- Pr ct: T ygkof In pection: Date called: /i-Jcj A ► G re y s / -5 � , Special intion: 1./ / b'l � � Date wanted:, Q a.m�) Requester Phon . �7 r b(p r 1 •9 3 7 3// 7 INSPECT, N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECO Retain a copy with permit Por/'r 7 \ PERMIT NO. (206)431 -3670 orrectlons required prior to approval. $47.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.. CaII to schedule reinspection. Receipt No: Date:" Project Ct (t ki) l eS l Type of Inspecpu 1 cut fG ‘• ), Addrg5 0 C /" ffi D ate called: Lt/ .. 7 . 7 Date wanted: l9 � p.m. Spe instructions: Requester� ql ~�L Phon poY 3 � ' 3q3 Z INSPECTION NO. 1■SOECTION RECO Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 114 1.0".' PERMIT NO. (206)431 -3670 pproved per applicable codes. Gag reci it d rior t ir $47.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: COMMENTS: 5 , 1 i /'h i/7 li S (2 lam. 7/72 Jc, �> ,r` „- 1)1-, 7�iti sP Date: COMMENTS: t9U / "- ..f / .. . ak-e' r- 02 0 O t - it.lt 'eti-i s . 1 too a . Lie/.7177, l e _ >ee., s ,. Special instructions: 0 r Lt -- -- ic-f "i2_ 44/ . ;7 P1-0 t i -.if it. cia,fri .4.e.)...,44---ein k 444-44.P.1- t.f...fr--er t /a z17'i 4 (.... 4., ,_ A.,- - ,,e ‘..., , A-1 c r9 17 A9/-1 ,-Ito../ V-. 6 4c,.../.. he-- AIL i tX..A„, - , L g A tfa--N n-bi Project:' it-r4S-i— Type of Inspect' : Address: c ....) Date called: Special instructions: 0 r Lt -- -- ic-f "i2_ Date wanted: 14 I q rf 442° 7 ' Requester:.---). Phone: (p1\ .eAp T at \ ' t INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Inspector Approved per applicable codes, fl Corrections required prior to approval. ' INSPECTION RECO Retain a copy with permit PERMIT NO (206)431-3670 Date:// 4 - ?7 El $47.00 REINSPECTION Jt REQUI ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd , Suite 100. Call to schedule reinspection, Receipt No: Date: COMMENTS: ) ' ie 5 fL �� 1//i1,� Ix. ( s A. � IO A27/&(.(146... 1 I7 ye-� Address: 1 O " C. Mt 1 ,, Date called: 0 . iv /, '$ . .4,6 t>LJ 14** It AA 6 /9— eat. /A.( Req�r- f"i'"/�-I 6... ��, /,,!' p,eovr '6 #1 I --- FbL ,tizi r /A (SP(—fl .../ ,e' 1,4 Pro' ct: Typ of Inspection: its Address: 1 O " C. Mt 1 ,, Date called: Special instructions: 4 , 77 , a.m. p.m. Req�r- f"i'"/�-I 6... ��, /,,!' Phone: • 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 0 Approved per applicable codes. INSPECTION RECO Retain a copy with per PERMIT NO. (206)431 -3670 orrections required prior to approval. $• .00 REINSPECTION FIE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: • ._:.-:Proj ect:_ \ Fares 'Addres 4 95 )0 5 C) (. t _Retain current inspection schedule Needs shift inspection 7.5)D City o TukvvUla A John W. Rants, Mayor Fire Department Thomas P. Keefe, Flrz Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL-FORM: Approved without correction notice X _ Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signat e Or FINALAPP.FRM Rev. 2/19/98 . "1/V1 "1+1er - von r••.r.. ew1 -.+Cr ,'tear Permit -.No ... n "`03 1 « _ V1 Suite # C i (,( ( \ Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 **.1*NA+^**a**+ CITY OF TUKWILA, *A+A*A10(*+A*A* TRANSMIT Number: Paymmnt Method: ..-_-_'-----�--`- ] ermit Not ,Parcel No: • Site Address: ********** WA +4*A*A+* R9800OVO CHECK No M98-0174 262304-90 290 SOUTH *^a*+**+f*A+*+A' =/ �� � ����L A*Ax*o++**++* Amount::. tation: PCL CON 8 Type: - NECH 04 CEN4E8:NALL ` Total Account Code Description 000/345.830 PLAN CHECK - NONRES 000/322.100 MECHANICAL,- N0NKFS ---~_-~-•--_-_-----'~-^._-_--.-..-_.•'._-.-~�-'--_--•••• *+***«4*++*+****»*AMv THANE/MIT *f+4^+*+**«* 474~00 01/05/99 09:23 STRUCTION Init: KJP MECHANICAL P�kM%T � Feesv . 474^0,0 Thi P= N t 474 0O Tutm� ALL Pmt: . 474 s y en . / � �O �� . � Q l 00 � ance: ' ^ *+7:*+***+*+^+*+*+++**+^+* . +*a*+*a71++ . .Amount , 941.9O ---- '" ~ --~' ��� Fan Equipment Schedule Equip ID Equip. ID Brand Name' Model No.' Total CFM CFM . SP' HP/BHP Flow Control Location of Service SEE driie/l1D ,Z4/1 S ,Er .N 70 0 Cooling Equipment Schedule Equip ID Brand Name' Model No' Capacrty' Total CFM OSA CFM Econo SEER or EER IPLV Location SEE driie/l1D SAY r . Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacdy Total CFM OSA cfm Econo Input Btuh Output Btuh Efficiency' ArMe -# .s4‘417- . Project Info Project Address - tt\t ,, t , � Gm :, Date SR _ i ( Q „at ; , — *.17-J II it , ; For Budding Department Use lu mLIQC, U) I c,. Applicant Name.' L. WI \C�� w �G totA 1}IGQ•Vl� l lsc . Ap•li ant Ad•r•ss: a Applicant Phone Tn1, lr, ( :ttts1 r x (t.\-t. ,D,x) cs� ,1 asnor' 1Or Mate "larres,denIfa E'e: ?y Code ComDba. •e Forms AO 1994 Project Description Briefly describe mechanical system type and features o o Frnp av; wir// 6.4s 4/4 Z v4 AND D)( ecoz.b. . Compliance Option Simple System ❑ Complex System ❑ Systems Analysis (See Decision Flowchart (over) for qualifications) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans For projects without plans. fill in the required information below. 'II available. 2 As tested according to Table 14-1, 14-2 or 14-3. a If required. ' COP, HSPF, Combustion Efficiency, or AFUE, I 4NO s Flow control types. VAV, constant volume, or vanabte speed. M1ori4 Pgelsecom CITY OF TUKWILA S E P 1 1 1998 PERMIT CENTER • Mechanical Sumr ry (back) MECH -SUM t944 Washington Stale Nonresidanosl Energy Coda Compliance Forms System Description See Section 1421 for full description of Simple System qualifications. Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. :X. 1994 Washin ton State Nonresidential Ener• C Ie Com • liance Form If Heating/Cooling or Cooling Only: Systems ype.; orCoo g —' - - —" Constant Volume ? no yes ,, Heating Only r' � :i .4'. Air Cooled? no <5000 cfm?' - -••• yes nor : Reference 't Y ; Sec, 1421 ; . <70% OA --Ai yes no If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? ❑ Constant vol? ❑ Split system? <54,000 Stull- rno"o 00 cfm? _.. yes (Includes) tEcono ?) nor yes yes .W. Rack _ - .,._._ - =>?•S m? no t i -- • k Reference Sec. 1423 • ••••"••••r•.••• ' SimpleS to Allows Reference 1 t Sec. 1420 1 ❑ Air cooled? ❑ Packaged sys? ❑ <54,000 Btuh7 ❑ Economizer included? • 'qr 1900 cfm? no . • . yes , • Split ._ . ., %•System? no yes <54,000 Btu)t 4 Use Complex System Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. tvl 1 Reference Sec. 1430 ADM, 1 •gt i • COOLING EQUIPMENT SCHEDULE Equip. ID Brand Name Model No. Capacity MBH Total CFM OSA CFM Econo SEER EER IPLV Location RTU -1 Trane YCD151 143.5 6000 1000 OSA 11.3 EER N/A Roof RTU -2 Trane YCD151 143.5 6000 1000 OSA 11.3 EER N/A Roof RTU -3 Trane YCD121 121.8 5000 900 OSA 11.5 EER N/A Roof RTU -4 Trane YCD360 353.8 12225 2500 OSA 9.5 EER N/A Roof RTU -5 Trane YCD049 47.5 1660 Ecnomizer 12.0 SEER N/A Roof RTU -6 Trane TCD074 65.1 2485 Ecnomizer 10.0 EER N/A Roof RTU -7 Trane TCD049 50.2 1890 Ecnomizer 12.0 SEER N/A Roof RTU -8 Trane TCD074 64.8 2400 Ecnomizer 10.0 EER N/A Roof MAU -1 Trane GRAA4OG 142.1 6000 6000 OSA N/A N/A Roof TF -1 Trane AHOA4OG N/A 10500 4000 OSA N/A N/A Roof HEATING EQUIPMENT SCHEDULE Equip. Brand ID Name Model No. Capacity Total CFM OSA CFM Econo Input BTUh Output BTUh Efficiency RTU -1 Trane YCD151 N/A 6000 1000 OSA 150,000 122,000 80% + RTU -2 Trane _ YCD151 N/A 6000 1000 OSA 150,000 122,000 80% + RTU -3 Trane YCD121 N/A 5000 9000SA 150,000 122,000 80% + RTU -4 Trane YCD360 N/A 12225 25000SA 350,000 283,500 80% + RTU -5 Trane YCD049 N/A 1660 Ecnomizer 90,000 73,000 80 %+ RTU -6 Trane TCD074 N/A 2485 Ecnomizer N/A N/A RTU -7 Trane TCD049 N/A 1890 Ecnomizer N/A N/A RTU -8 Trane TCD074 N/A 2400 Ecnomizer N/A N/A MAU -1 Trane GRAA4OG N/A 6000 6000 OSA 400,000 320,000 80% + TF -1 Trane AHOA4OG N/A 10500 4000 OSA N/A N/A MECHANICAL SUMMARY Mechanicat Permit P17 Checklist MECH -CHK t994 Washington State Energy Code Comohane, Forms A DnI 199.1 wl A ;�,(/�,- , {(� p/�,, 1 �} r /� Date ' 1 .. Z Project Address is b C, trIt ►c �rz. ' ' ` L 1 ...�1 ill . p �1 / the following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (circle one) Code Section Component Information Required Location on Plans Budding Department Notes •T, - o g - V 1 ecttons 4 - • • 1411 Eqpmt performance yes no n. 1411 4 Pkg. elec. htg.8 clg. List heat pumps on schedule yes no n a. 1411 1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1412 HVAC controls yes no n.a. 1412.1 Temperature zones Indicate locations on plans /}1,10 0 es no n a. 1412.2 Deadband control Indicate 5 degree deadband minimum FAO igcrr'11ANUAL — es no n.a. 1412.3 Humidity control Indicate humidistat AA 00 es no n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 different clay types PM/ •es no n a. 1412.4.1 Dampers Indicate damper location and automatic controls MO IS no n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule ,Cf no 1412.6 Combustion htg. Indicate modulating or staged control ...-. es no n.a. 1412.7 Balancing Indicate balancing features on plans 0100 /yla/O ,»jb r ye no n a. 1422 Thermostat interlock Indicate thermostat interlock on plans —. yes no n a. 1423 Economizers Equipment schedule /N500 1413 Air economizers _..,. (114 no n a 1413 1 Operation Indicate 100% capability on schedule OLP j no n.a, 1413.2 Control Indicate controls able to evaluate outside air Neer IJ1q, ,RL - -- no n a 1413.3 Int •rated o• ration Indicate ca.abili for •artial coolin• O.. IL; .._• 1414 Ducting systems -•..•■•, yes no n.a 1414.1 Duct sealing Indicate sealing necessary ! • r' Mid LIAI., _ es no n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct A , or )1AdvA -- yes no n a. 1415.1 Piping insulation Indicate R -value of insulation an piping ' r . Et:? - ,N9Xr/4L --• es no n.a. 1424 Separate air sys. Indicate separate systems on plans //94 00 es no Mech. Sum, Form Completed and attached. Equipment schedule with types, in•uUout•ut, efficienc , cfm, h.. economizer .D - v r. - . 1 ail - • a -•• ections • ►r - • • 1440 Service water ht.. yes no a 1441 Elec. water heater Indicate R -10 insulation under tank yes no n.a 1442 Shut -off controls Indicate automatic shut -off 1450 Heated pools yes no n. ( 1452 Pool water heaters Indicate not electric resistance yes no n.a. 1453 Pool heater controls Indicate switch and 65 degree control yes no n.a. 1454 Pool covers Indicate vapor retardant cover yes no . 1454 1454 Pools 90« degrees Indicate R -12 pool cover . 1 ■•• • • .. -- .....' . - .. . • • _.. . o is ctrctea for any ques ;on, provi exp anatton: .RECEIVED CITY OF TUKWILA SEP 1 1998 PERMIT CENTER 1994 Washin•ton State Nonresidential Energy Coda Compliance Form Mechanical Permit cans Checklist 199a wasmngton Slate Energy .ode Comoi Forms .MECH-CHK Bo !99/ Mechanical - General Requirements 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone 1412,2 Oeadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: , • 1 Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2 Buildings complying with Section 1141.4, if in the proposed butlding,energy analysis. heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture. a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems, shall be equipped with automatic controls capable of accorihplishing a•reduction of energy use through control setback or equipment,shutdown during periods of non-use or alternate use of the spaces served by the systen.•The automatic controls shall have a minimum seven -day clock and be capable of being se1 for seven different day types per week.' ' ' Exceptions: 1. Systems serving areas which require continuous operation at the same•temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less miy'be controlled by readily accessible manual off- hour controls, 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the systom is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open dampers. These dampers shall remain closed in normal operation until activated by the fire alarm system or other approved smoke detection system Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shalt indicate when supplemental heating is being used through visual means (e.g.. LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/ti shall have modulating or staged combustion control. Exceptions: 1, Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413,2 Control: Air economizers shall be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when i:. additional mechanical cooling is required to meet the remainder of the cooling load Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual. direct expansion cooling systems with capacities not greater than 75.000 Btu/h may include controls that limit simultaneous operation of the . economizer and mechanical cooling for the purpose of preventing ice formation on cooling coifs. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18 Extent of sealing required is as follows 1. Static pressure' 1/2 inch to 2 inches: seal transverse pints 2. Static pressure 2 inches to 3 inches: seal all transverse joints- and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse taints, : • longitudinal seams and duct wall penetrations ._. - 1414.2 Insulation: Ducts and plenums that are constructed as part of the budding envelope shall meet the requirements of Chapter 13. Other ducts• and plenums shall be thermally insulated per Table 14.5. Exception's: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. J, Exposed ductwork within a space that serves that space only 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. Exception: Piping installed within unitary HVAC equipment. . Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: a. Air cooled, constant volume packaged equipment. which provide heating, cooling or both, and require only external connection to duct work and energy services. b. Air cooled, constant volume split systems, which provide heating, cooling or both, with cooling capacity of 54,000 Btu/h or less. c. Heating only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total au circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements in Section 1412. where separate heating and cooling equipment serve the same temperature zone, thermostats shall be interlocked to prevent simultaneous heating and cooling. 1423 Economizers: Economizers meeting the requirements of Section ■1413 shall be installed on packaged roof top fan - cooling units having a supply capacity of greater than 1,900 cfm or a total cooling capacity greater than 54,000 Btu /h. The total capacity of all units without economizers shall not exceed 240.000 8tu/h per building. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. •' ec anrca - omp a ys ems ec is 1 19. Wasninglbn State Energy Cod. Compb.rte. Fame . a - • MP Aprit. 1994 r� Protect Address 71_0 S ouk m i n 1 ry, I p —� I O Date _ C', - z = The following additional information is necessary to check a mechanical permit application for a complex mechanical ,system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable attemative. For Building Oepartment Use Applicability (circle one) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY ,yes no n.a. 1431.1 Field assem. sys. Provide calculations _ 1432 Controls yes no n.a. 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2 Temp. reset control . yes no n.a. 1432.2.1 Air systems Indicate automatic reset yes no n.a. 1432.2.2 Hydronic systems Indicate automatic reset yes no n.a. 1433 Economizers Indicate economizer on equipment schedule or provide calculations to justify exemption yes no n.a. 1434 Separate air sys. Indicate separate systems on plans yes no n.a. 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified yes no n.a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations yes no n.a. 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp. rpm, efficiency des no n.a. 1438 Variable flow sus. Indicate variable flow on fan and pump schedules ` no is circled for any question, provide explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. • • S.attar 11!12 Ye . Capacity oCHW ' Ha Watcr Supply Homy Systen Tanpcnturc Ract Grate Than Controls Required . 000.000 EMI' t 0 Satyr 1411.1 Equipment Pei. Shall Mat Table 14.1 throw* 143 Fuld- ' Yea Assembled No; Swiss 1432.2.1 Supply M Rant Connote Rcqured Av No System �- Saving Multiple • Zones (continued on back) CITY OF ETUKWILA SEP 1 1 1998 PERMIT CENTER 1411.3 Fronde Microprocessor He Pump Controls 1994 Washi ton State Nonresidential Ener• C • - '1 Com ' Form • Mechanical - Con . ex Systems (back) MECH -COMP 1904 Washington State Nonrestdsnoal Energy Code Complunce Fortes Cooling I .ipaaty 20.000 Muhl , • Yes • Heating a Electne Cooling in one Package? . • No No ,•• Application Involves Venable Flows?: f, / 0 (continued from front) Done Non•Electnc Electric •' MiWh• \ Motor Ell*nency No speed . No Included in Egwpmet Motor in a •—•► Performance Multi•speed • Roane System? • Yee Settler 1433 Air•Side Economizer Required gee Yo Fans a Runps� Fu 10 HP? 0 &wage 1435 Fen Powered Urinal Units Regtid r Supply\ &Knee 1434 5000 C.•FM a ` 50% Mane Outside Ar Hew Recovery 70%7 System Regvred /Caelit. • Y ea Packager No / Cooling No 0 Tod 9155 No Roof) C C s 11, 7� Unit? 111,0 Stuh� •• 210, rt1 Session 1435 Yriable Flaw Drrices RwItIreft Session MS 3inermtsom Hoeing co Prololwa+ 1 Yee Apnl, 1994 • Open Motors Closed Motors 3.600 1 1.800 1.200 3.600 1.800 1.200 Efficiency (%) Efficiency (%) • 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84 0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 _ 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93,0 93.0 91.7 93.0 93.0 92.4 93,0 93.0 92.4 93.0 93.0 93.0 93.8 93.8 93.0 93.6 93.6 93.0 94.1 , 93.6 93.0 94.1 93.6 93.0 94,1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 _ 94.5 94.5 94.1 93.6 95,0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Electric Motors MECH -MOT t 994 waimngton Stale Energy Code Comooadde Form% Project Address '1Go , ) (--x Q��- 1! 1 Complete the following for all design A & 8 squirrel-cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1.00 rpm (unless one of the exceptions below applies). E" .2 Gi tEb c SE Motor No or Location Synchronous Speed (RPM) HP 10 t5 2.0 3,0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 • • v■■■••• . 4VI /I V•IVL:I %m.i iol Vuul l,Uf11EJ1 {dr1Ca rorm Type HP (open or closed) Description of Application or Use jirc1/0/41 hbeD Ori/Adsr Klrc.NE,J /,ib 6)c#Rd5 Date 7 For Building Department Use Synch. Speed Min.Nom. Full load Efficiency 97.S - RQ. Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14-1 or 14 . 3. Motors that are an integral part (Le. not easily removed and replaced of specialized process equipment (i.e. equipment which requires a special motor. such as an explosion -proof motor). 4. Motors Integral to a listed piece of equipment for which no qualifying motor has been approved (Le. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. April 1994 • CITY OP TUKWILA SEP 1 1 1998 PERMIT CENTER Dear Sir: ( - . City of Tukwila Fire Department Fire Department Review Control #M98 -0174 (510) Re: Rainforest Cafe - 290 Southcenter Mall September 23, 1998 Dedicated fire alarm system circuit breaker(s) shall John W. Rants, Mayor Thomas P. Keefe, Fin Chief The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1742) 2. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 Yours truly, cc: TFD file ncd City of Tukwila Fire Department Page number 2 be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Duct smoke detectors shall be capable of being reset from the alarm panel.. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) 3. Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when the system is actuated. (UFC 1006) 4. A sodium bicarbonate or potassium bicarbonate dry - chemical -type portable fire extinguisher having a minimum rating of 40 -B shall be installed within 30 feet (9144 mm) of commercial food heat - processing equipment, as measured along an unobstructed path of travel. (UFC 1006.2.7) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. sla The Tukwila Fire Prevention Bureau John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Plane: (206) 575.4404. • Fax (206) 5754439 REGISTERED AS PROVIDED BY LAW AS s:� CONST CONT GENERAL REGIST. # EXP. DATE CCO1 PCLCOSI099NW 06/01/1999 EFFECTIVE DATE 08/16/1991 1 P C L CONSTRUCTION SRVC INC PO BOX 52868 BELLEVUE WA 98015 -2868 Signutu Issued by DEPARTMENT OF LABOR AND INDUSTRIES TYPE RATING PLAN DESCRIPTION O I- HOUR RATED ENCLOSURE ULV4s 04 E " Ice MEWL FIBER SL110 ADEntlATION IN ID CAN,. SEE PLANS FOR LOCATION • 1f 1( )(11101 10 . 1 1 ) 1 1 1 1 1 1 1 1 1 TEMPLESTONE ON ONE SIDE OF WALL O I- 2 HOUR RATED ENCLOSURE ENC! 05 ULV465 0 06 ABOVE E0160141 STUD 015-1 O I- HOUR RATED ENCLOSURE UL'J465 ovDERSIDE DE DECK ABOVE O NON - RATED CONSTRUCTION PLANS FON 6 GIG Bo E56 5 2 UNDERSIDE CLG DECK Ate. h TD -.. NON -RATED CONSTRUCTION )a GSM. SDDE a DE AEONS I.E 065550.NoTED Fran M CANT'. SEE PLANS FOR LOCATION '. )(11)()(1(x(1( r (llNMIRIl). 6 O CONSTRUCTION NON - RATED 2' Ote EACH NIDE OF 3 52'ere GA NET. 6E06 AT I6 o1,- .1.13 TO .'ABOVE 106. E LATERAL BRAGt.is REQu101E90 0. FRONDS 3' MINERA_ FBER ENg ION NSTW c R LOCATION , ` - 1 1 N ONRA 3 00 - 544 l0TION 0W 6T1106 le DC S TO . SEE PLAN FOR I O NON - RATED CONSTRUCTION T ... O GFRO ROCK ON 0N'E 5105. % GFRC ROCK ON 80TH SIDES O GFRG ROCK, WATERPROOFING (BY ARTIFICIAL ROCK VENDOR) ON 3/4' FRT PLYWOOD AT WET SIDE OF WAIL TEMPLESTONE ON BOTH SIDE5 % TEMPLESTONE ON ONE SIDE OF WALL S°IIIUTHCENT1ER MAL ABBREVIATIONS A/C air OdlLIonfocla 9) AN audio visual AB end boll ALL access ACT .00 1, . 441.1d 5 ills ADD addena, ADDL eddltmral ADJ aeaaaa, adjustable AF above rmleSed floor AGG aggregate ALT alternate AIM alml,ue 4WD modulo T4RDX approximate ARCH arebtec4enab NITO automatic BR btbmlmus BLDG building 1.K bbd: BLED bbdJng B•1 boars e0T bottom 5RD beard MG bear g CAB cAbinet CI caot Iron LIP. cast In place CR circle W control joint CL alter Ile CLG all g CLR c1a1Na¢a) Rrl 400418 51.00)41 COL colon LONG • ate ANIT conetruction or Cast 54 168 o 0tbu, CORD dumb, eoordmatlm CPT carpel( GeV C^J-1K 031 CT )1 00054 Ole DE dNbio famen DIN dl enamor meter DIM 17I6P dispenser DM abut DR ul D d9 l2111 NSW drawbars) E east END electric hand dryer EL elevation ELEC eleclri EFON erlc membrane .9011 00 ED equal EQJIP equipment EXIST wishing XP n expansion Joint EMT exba • FD floor. drain FE fire ex5MgvIser F: MA _ FIN I FIX( Px 1 1 - 5LR noan,g) R6HG flaehin :LUOR Puor)cert FR framed( Ong, ENP fiberglass reln(orrm panels ER' fire tardenl treated FI5 footing RJR furrealnei MT future GA 104.4 galvanized � GC general conbaoll or ) GFRC gl 1161 ren(ocad GEN general GL glass, glazing GUS gypsum wallboard W C 055i1ap NB roe, blob HC manbcapf pad))ollow ccre,h000 [Abbot 111 ham natal e NORZ dzi Tel 611 ialght ui Ion Icy 6IVA0 4 g m� mg D mde datoter INCL isoludelea Dg, 40.1101,1103 Nr x Nv invert JAN Janitor Jt Joint pr 1 wt KO (808)03 AV la to MAx0 manurecluredr ) MAX maximum 11604 64:0 eU 100 mato '1ATERIALS T}PBR member. NET metal MM mines KR mirror M miscellaneous MO mea openby MD nailed MALL w N OW NIC gal M contract NO,. ember NCM wmMe1 NTS sot to scale CC on cartes) CCC occupant(.) OD outbids 1 dimmer fF/GI era a Installed 6101 Guar fine.. - W ,11041 oura OH overhead, oval , )541 , opposite Nrd ORY openbg PART BD paNCbward PERP perpendicular PL plate PLAN plastic Rebate PLS. p44abg 51,1110 plywood PN5 panel Re pair PREFAB prefabricated PREEN pre leied 5150 p100pg ' property PT peb5led) PTO papa towel die/mosses 011 gmdny R 'leer RADNR) redlus RD roof deln NEC recommol RECPT receptecie REF reference, refrigerator RENE remrance66, 5000 FEOD requred 040 reverse REEL IN), five), for) 5040 V 01 room 50 rough coming RV roof van 5 earth BAN sanitary SC solid core 54)10 schedule 6D 54 8:11381 SECT sectIcA 5F square roatfe0eureet SIT sheet ONTO .eaulbg BIM slmllar BL 1 N BND ry napkin dispeua BPEC(51 541241 aOo(s) 111.4.5 priskie 60 68' Loanss steel 510 'Abed 611 steel 6TOR storage 615101 stn.etsral 5855 snperded 568 system TG tongue end 510004 i tfedd (enra5 at TEL telephone TEMP temperature / lenpaery 1.. 111.4 .. 11.IFE5H lkeeb0 Toe top of bean I TOL tap of ovicsopincv T4F top of rooting TOM lop off; detbn well TOG top of slab'. 051 top or steal TDU top or all 1FART toile petit!.. IMP typical INEXC tsexcavated SPIN unaruNved IN0 01sas noted wermso �IU I 0ER1 VR ram OE nth 0 wltho4 000 BC Uotd Aloe. 0 wood WW1 window 01 well hag LEE 104110 welded afro CONCRETE FIRE RETARDANT TREATED PLYWOOD PARTICLE BOARD WLiW11UlUlll ACOUSTICAL TILE FINISHED WOOD 00N0RE1E 8LOOK STEELANETAL STUDS BATT INSULATION RIGID INSULATION �;•';".. PLASTER GYP. BOARD BLOCICING'FIRE RETARDANT TREATED 00011104 LUMBER © F5 ROOM. LLGI FIN FIN BASE FIN RR w RBURC5 �] SYMBOLS SECTION MARKER Section Identification • seer 5:100 a«tion appears �Da emdxue - RMNAME STORAGE ROOM'. N Pf.) AT. E Pr EXTERIOR ELEV. MARKER Elevation IdentlfIcallon Gael w4ea elevation appears i��♦ DETAIL MARKER 1: Rolatn date 1 area Delal identification son doe detail appears INTERIOR ELEV. MARKER ( AEI. Id If lion i A3e , Soot 540e sleANI0 eppea2 DOOR MARKER Door rumba le numbA of room door 51.S5 d begin The enteric' with an •%• (X105) S'OT ELEVATION HEIGHT/ELEVATION MARKER PARTITION 1ARKER. Q'A2P V N P01Il/ n15500 ��10 01:1odlbl3)) SECONDARY ELEVATION MARKER (top of parapet, ME etc) REVISION MARKER ROOM FINISH MARKER WALL PARTITION TYPES • ROCK UJALL FINISH TYPES GENERAL NOTES PROJECT I E4 NAME: 4000`55: 400,1 ?HONE No= FAX No.. CONTACT LAND' a D NAME 4000055: PCL CO551141107104 SERVICEL, 110 330 :APES ,AVEL SOUTH BLOOMINGTON, NGTON, :MINNESOTA 5543 (66) 008 -9200 (8 4133 DONn'c01 HE RICHARD F. JACOB5 GROUP, 'NC 25475 CENTER RIDGE ROAD CLEVELAND, ANN OH 44145-452 HONE 1o. (216) 8114800 FAX No.. (216) 532 -2308 CONTACT BRAD 5X0000 STRUCTURAL ENGINEER NAME: REIG5TAD AND ASSOCIATES ADDRE55 152 WEST 9114 STREET, SUITE 200 50 PAJL,IM NN SOTA 55102 PHONICS No: (612) 292-1123 FAX No: (512) 292 -000 CONTACT: BILL LINDA. MECHANICAL ENGINEER' NAME N (PAL D COO_EY ERICK50N ADDRESS: 1200 715764Q0Q3./749 05:0 144 3 350135 SEVENTH ST-ET MINNEAPOLIS, MINNESOTA 55402 PHONE No (612) 335 -4941 FAX No. (612) 335 -5354 CONTACT RICK IVERSON RAs'.. 400 455 4E No.: FAX No aSNITACT:: AD03055: PHONE No.: FAX No, G.TNERAL WALL PAR1DION TTPG N0105'.. PROVIDE WATER @Sus A . GYPS, " 420 = / 15/: IN ALL 'ROOMS <170cEN AREA AT ALL 51NK5, 015.,0451 -'LNG. 1ND E(1.F^'1 WA-_S, HAS FAT 40 . , 0/300400 RDD" •' 70 A 0 A= AT 11'1.7'4' ON AND 4 -0'J 011' ROOMS. 2. ALL 0131001'04__5 7 L., 00 0101 50 TO T= • • C <0< 4-.s 3R.':0=ED 47 45 0EGREE5 TO 5-81100 400VE. AT 4'_C' OL - 5=E DE-4'_ 1/4522) 3 REFER TO FLOOR FLANS •' G fALL T7X=5 TIa=t7 NOT FULL DES, /HALF WALLS). 4. P-_' - R TO 'ROCK CAL _ ENS4 TE. FOR AVE SA,N C\ PLAN WITH A LETTER DESIGNATION AFTER THE WALL TYPE 5013 EX4.. = 5A. 5. INSTALL 3 /4' FIRE •-4RO4'4T :5A7-M F_.: (.COD 571E Dg-L5 JIT G"'^ N LEI/ OE GIr3, EXCEPT ,+T FIRE RATED WALLS'!.5ERE PLYWOOD WOULD r Nt SEAL= 0Y -R0r_: . 6. PROVIDE 3' SOUND ATTE'04110'4 AT A'1 CCEFEDOR 1A_ AND _0i1100 0..,,.5 3075_E1 DINING/TAIL AND POLIO. RESTROOMS. 5E- PLAT FOR OTHER O.-A. ON.. 1. IN KITCHEN A0D SERV' '4 E2S H= BO1 .. D G PAR71110N S-',ALL 5E CE=N : VOUS BACCRS0ARD IN LIEU CF GTP51.111 WALL BOARD S__ DETAIL JA GENERAL ROCK WALL FN154 NOTES: 1. REFER TO 515414TIO1S AND 51054) FLAN FOR Etbc,NT 6 R DO.DOc I. Rn =Prl.CE DIMENSIONS AE TO 3E n b5AS_ 0.!'. 5-7. 00010 LI 80 6 0/GSTti: CO! U`L45. 2. ALL DIIT_`51OS 51+0WN 9T EFT_ 21_ ST! D •n,"t' A 4< -D TY 11150 FACE= CP 343 G 5411 WALLBOARD OR TO FACE OF 5TUO AT WALLS WITH 1 `(1.513 500E9- 3. 0440505 IN TIE FINISH COR ,ATERA 5 D O0C..F AT DOOR CEN"__ZI 'NE UNLESS NOTED OTHERWISE., 4. PORTION'S OP TH c I5FOR18 ION 500.00 CV - 'rte 74A01155 LET` IAI•I PRO: Ss:STENS DRALNGS AND ON 5 TE 055ERV41IT)5. DRAl`Y5 ARE NOT - A5-EL- V CO'1,0l1 5 AND T.-E. CON'TRAC'TOR SHALL FIELD 2054191113119)5(051452 ACTUAL LN0TALLED CON7 104. SHG'J ANT C0/ a A2.r_ 3::E A . CONDITION) AND THOSE 5:3'51100 THE 054010'G5, TI000541RACTOR 54411 NOrEE1 4RC'T -CT 0=5,100' C-ON PROCEED N'G 5:1 THESE DR4M1Y5 504(1 SOT SE 5 "D FOR OfA0T 132 N51ON5. 5. THE CONTRACTOR SHALL COOa6N4 - AND 500-2150 ALL 5100III TH APPROVAL 09 Q.I`LR AND ! AYJL004 WITH (DE LNTE6) CE ':NPIIZ510 D SR.PTION TO DQSTOG FI.N'CPONS_ 6. PROVIDE A'11A0IbtliCAPACITY' 5054 ALL 1 A- WOOD 5T OG<PG 4N7 PLYWOOD ' BE -IRE •(4RD414 n�A?ED Y'M 54 -34TION. 8 IN ALL 400115 L'J14 POOR 054481.5_'0: ._002 TO DRAM AT 1/4 PER 1 5_MECHI DIPS POR DRA4 LOCATION. 5 MALL 0403/ 04415 FR^'.BT 15 4'1111841 TO15410ISTM1.. DEC OR Tr_ 1055TRAiONCF EXISTING 5TEE D•K.. J0150 ETC. 5_ MA'_CT5<TION MAN.._ F40GEFT43 11 0' 0.0050 =AP AC-Mn'•0..X151N0- STR.LTLRAL EL NtS ^S_ COiMEAC OR 54A_ EV'4 TEE MANUAL PRIOR TO 01410N5 ANY WORK 'OW\''.ER ELFCTRICALENGINEER RAIN=0005 GA:', INC 20 sam 9.754 5T-ET 0 }1'L5O 4 55343 PHONE No, (b 945-5472 A> No - 7 _45 5� CONTACT: MARC 5141 5T AR `TECT NAYS: 0(N1.-14 PA alITER ADDRESS: 2525 N. CEVR4_ AVENUE, SUI .. 170 PHOENIX. ARIZONA A 55004 PHONE No, (50') 255- 165 FAX No, . (502) 265-1153 CONTACT: DAVID NC'IA GENERAL CONTRACTOR NA.- 111,041)0 COOLEY EYECKSON 40(,.0055: 1200 METROPOLITAN 0E51TR= 333 SOUTH SEVENTH STREET 710304903.15, 110045010 55402 P 01_No: (-) 394941 • FAX No • (CV 39.0354 • CONTACT: 1..11ELLE SHAFFER LUATER FEATURE DE5!GNER OLYMPIC. POOLS INC. 50 214000 5 40PE5,1`!N. 55319 (5 (6./445 1551 GREG 5TOK5 LIGHTING DESIGNER NA, 51494055 49054 =55: 0 METROPOLITAN CENTRE 3":3 SOUTH SEVENTH STREET NHEAPOLI5, MIINNESOIA 55402. PH. No.: (612)613 -5925. FA.: No: (442)337 -5091 CONTACT KEITH DEFe'0E5E AUDIO /VISUA.DES - NAME F 4TTALONE AND ASSOCIATES ADDRESS: 2E55 CENTERVILLE RD. LITTLE CANADA, MINNESOTA 55111 PHONE No: (612) 544-3300 FAX No_ /5')) 445 - 6146 CONTACT: 5'EvE FRATTAL ONE OWNERS KITCHEN DESIGNEIR NAME, 1 DFI FOOD 5ERV GE '6QUIFIIE5T AND DESIGN ADD0055: 3505 NORTH 2911H A F. H LLY'J10OD, FLORIO A 113020 PHONE Nov (554) 920-9499 FAX No, (54) 20 -9502 CONTACT: 11<51,4551,51 OW":ER5 RETAIL PE5 79355 NORTHWESTERN 4111'. PO. FOX 5141 50UT0FI.LD, MI 450,4 (510) 355 -0590 (510) 355-0595 0,5 s;;vii ARCHITECTURAL G000 INDEX, KET PLAN, MATERIALS, SYMBOLS AND WALL TYPES RV CODE ANALTSI5 PLAN 4001 511E PLAN A101 FLOOR PLAN A01 ENLARGED PLANS - FRONT OF 0045E 112 ENLARGED PL4015 - BACK OF HOJ55 5NL A.R.aED PLAN) - VIGNETTES AND RETAIL PLAN DETAILS A201 - AR11AL Rob PLAN A130) E 1 ERIOR ELEVATIONS AND SECTIONS 4311 INT., IOR ELEVA7lONF • MALL STOREFRONT .'312 INTER n, - 4CLEVA70N5 • FRONT OF HOUSE A313 INTERI0 : ELEVATION) - MISC. AND BACK OF HOSE 4314 INTERIOR • EVA -10N5 - BACK OF HOUSE A315 INTERIOR EL VATIONS - RETAIL A411 SECTIONS A4)1 111SGEL L4NE0 MALL DETAILS 4422 MISCELLANEOLS, 8790010E1'81LS 4501 DOOR SCHEDULE AN DETAILS A602 DOOR AND WINC11'41__ 4101 FINISH PL4N 4121 FINISH 0000011 F AN^ CA - 0 RK DETAILS Al22 INTERIOR AND F.::3H DETAIL 4001 REF L 5 0TED CEIL NG PLAN A021 CEILING DETAIL5 F101 WRNIPJRE PLAN O ! 5000 TURN1 NOF5 01 ' 5100 ION PLAN J_ 5200 ROOF INS FLAN ' 53001 SECTION$ DETAIL5 ® } 5301 SECTIONS AND - TA" 5 5000 T MECHANICAL O I 1] STRUCTURAL 11000 05044NICAL SHEET INDEX, SYMBOL) a 400REVI4•IONS ('1100 IINDE0LCOR PLumaNG PLAN 6110 4000011100554,06030111.20 11120 KITCHEN UNDERFLOOR PLUMBING PLAN 11130. KITCHEN ABOVE FLOOR PLUMBING PLAN' M140 BAR IaN'DE00LOOR AND ABOVE FLOOR PLUMBING PLAN �� MI50 PUBLIC TOILET PLUMBING 015ER PLAN5 UM �� 1140 PLUMBING KET NOTE5 CBE 5200 H.VAC. PLAN n 5210 KITCHEN H.VA0 PLAN 11300 ROOF. H.VAC. / PLUMBING PLAN M400 911E 515010011011 PLAN 11500 MECHANICAL 5CE0 /5,5 `1510 MECHANICAL DE A1L5 551 MECHANICAL DETAIL5 11512 MECHANICAL DETAILS 5600 UNDEFLOOR 5)05 PIPING PLAN M6:0 ABOVE FLOOR 545W PIPING PLAN 541' ELECTRICAL OWN 0 SEPARATE PERMIT REQUIRED. FOR: ❑ MECHANICAL ['ELECTRICAL I P UMBING 4 PIPING CITY OF TUKWILA BUILDING DIVISION -.. 50010 ELECTRICAL v 4T:N5, 5 3)0 _ DRAWING INDEX 0 0100 FIRST FLOOR LIGHTING PLAN 0101 LIGHTING PLAN NOTES AND CONTROL RISER DIAGRAM FIRST FLOG EGRESS LIGHTING PLAN EI FIRST FLOOR SPECIAL LIGHTING EFFECTS O3 510 MUSHROOM RSF CT(D CE' ING PLAN O '5200 551 FLOOR PC0PR PLAN O 1 5201 F T FLOOR POJPR PLAN NOTES 3 I '520 POUR PLAN O E20 /CI G FNI PM ER PLAN RCM :204 M1.1514 05 BAR ANC. SERVICSAREA PO.ER PLANS a E205 (01101 IEN, MUSHR005 BAR 4005041'b01 MREA J 501)1 .'ENT SCHEDULES 1205 34004014 0300 FIRST FLOOR Y TEMS PLAN' 01 FIRST FLOOR5 - ED, PLAN NO ( 4 0 0 5 5 5 1 11 1 0 54 0 1 0 - LAN • 5401 FIR5 P_O0R 571 .IAL EPECT PL O 4402 AUDIO 0ONSJ T.V DETAIL5 • T 0500 ELECTRICAL, 7(1194 '05 AND F0 ROOM DETA: 5 E600 EQUIPMENT 501, JOL5 _I 0601 LIGHT FIXTURE E 4E!UL 0602 DIMMER SOH D _5 • B 8100 P8NEL30ARD IEDULE5 5000 515ER DIAGRAM S1-1T' WATER FEATURE. SUBMITTED AS;H0P DRAWINGS HT" RETAIL SUBMITTED AS':;OF DRAWINGS (OWNERS CONSULTANT) OCT 1 6 199 A) 3104 45LC1115 OR'lat (COMERS CONSULTANT) sup FOOD SERVICE . SUBMITTED AS 610P DRAWI5G5 TILE COPY Flan C ..J omissiontl t.t.1 1 p0 4 0 5 0 3 5 3 1 1 1 1 0 1 not „J cod.. of ortlitillwa 1 11ftypt of COntractoes copy of aped OMB pr y� 4Cd- nf zrr•- yl,.., Date REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL' OF TUKWILA BUILDING DIVISION. 1,71E PCVOarS WILL MILD. A NEW PLAN 5 CITY 59 TUKWILA APP(44 /5.. 55 Date Description Comm. /10. 0.0.... No r:.'D.Df Tea RAI NFOP ST GA?E SrAe: TSe -.: CMIF.E )1S(TI &01D 0101(3cture hr,rrof Design _ea;truction Serials 2120 9 Uentro1 Avenue 71ite 1110 Mewls, Az 83/04 Telephone: 601 tea -7769 502 -2E5 -7763 r : r ntngham.com Tale 07/02 /fig {{ REC STESO') 1 55151085' i. DEIN Y + f1 TE OF WAS5iN0T0i1 1 SgpeU: v gZ J South center Mali Tukwila, WA 07175 1X7 go INDEX, KEY PLAN, MATIR1 SYMBOLS, AND WALL TYPES COY OFI UMNIIA 1 7 1 1 1598 )I, PEFAO'Cd7TEiR� v Sleet. Ntor�" MECHANICAL GRAPHIC SYMBOLS SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION A1100 UNDERFLOOR PLUMBING PLAN. (WALL) 10 THERMOSTAT (CEILING) 0 THERMOSTAT (CEILING) 6 HUMIDISTAT -' -- - - -- M120 KITCHEN' UNDERFLOOR PLUMBING PLAN J( PIPE ANCHOR KITCHEN ABOVE FLOOR ,PLUMBING PLAN CAPPED PIPE BAR UNDERFLOOR AND ABOVE FLOOR PLUMBING PLAN —.- SUPPLY AIR CI CONCENTRIC REDUCER M160 —N—.- RETURN AIR —11L.. EXHAUST AIR ECCENTRIC REDUCER HVAC PLAN / DIRECTION OF FLOW KITCHEN HVAC PLAN 18/12 ANDTDEPTM (OR VISIBLE SIDE) FLEXIBLE CONNECTOR 4400 b leo 9 DUCT DIAMETER �.r FLOW FITTING MECHANICAL SCHEDULES ® SUPPLY AIR DUCT SECTION I /I RETURN CT SECTIO OR EXHAUST N AIR V DU 1941 OUTSIDE AIR DUCT SECTION FLOW SWATCH 4511 = PIPE GUIDE T TEMPERATURE/PRESSURE FITTING 4512 PRESSURE GAUGE WITH VALVE THERMOMETER S 3 AUTOMATIC FIRE DAMPER UNDERFLOOR SHOW PIPING PLAN M610 D C A O N th M MPI ER ATON FIRE/SMOKE —Q SIGHT GLASS 1 STRAINER g ba g 5 la MANUAL VOLUME AMPER E UNION 0 POINT OF CONNECTION. NEW TO EXISTING 1 + T 1 MOTORIZED DAMPER 1 } 1 3 1L BACKDRAFT DAMPER ® EQUIPMENT TAG AND NUMBER LL M OUGT TAKEOFF W /BEOUTH FAN, DIAGRAMMATIC 0 PUMP, DIAGRAMMATIC RECTANGULAR BRANCH DUCT TAKE -OFF A-200 ® ,( FITTING 460 BALANCING DAMPER• (TM OF y} -B (TYPE CFMN NECK SIZE) PRE PROTECTION —FS FIRE SPRINKLER UNE • PENDANT SPRINKLER HEAD -�'.0 •, 2 UPRIGHT SPRINKLER HEAD ,.: • - 55 OUTSIDE STEM & WOKE VALVE, CONICAL SPIN -IN BRANCH DUCT W /BALANCING DAMPER I,� SINGLE UNE DUCTWORK \ 1 -I. L ECCENTRIC REDUCER DUCT TAKE -OFF FOR BRANCH VELOCITY LESS THAN 1200. FPM CONICAL SPIN -IN BRANCH DUCT W/OALANCING DAMPER RECTANGULAR BRANCH DUCT TAKE -OFF W /SUPERM50RY 5107661 J4FA ;~ 1 DUCT TURNS (SUPPLY SHOWN) WATER FLOW ALARM WATER GAUGE W /SHUTOFF VALVE MECHANICAL DRAWING INDEX DRAWING NO. DRAWING TITLE 4000 MECHANICAL SHEET INDEX, SYMBOLS, & ABBREVIATIONS A1100 UNDERFLOOR PLUMBING PLAN. M110 ABOVE FLOOR PLUMBING PLAN M120 KITCHEN' UNDERFLOOR PLUMBING PLAN M130 KITCHEN ABOVE FLOOR ,PLUMBING PLAN M140 BAR UNDERFLOOR AND ABOVE FLOOR PLUMBING PLAN M150 PUBUC TOILET, PLUMBING RISER PLANS M160 PLUMBING KEY ',NOTES M200 HVAC PLAN 4210 KITCHEN HVAC PLAN M300 ROOF HVAC /PLUMBING PLAN 4400 FIRE PROTECTION PLAN M500 MECHANICAL SCHEDULES 4510 MECHANICAL DETAILS 4511 MECHANICAL DETAILS 4512 MECHANICAL DETAILS 4600 UNDERFLOOR SHOW PIPING PLAN M610 ABOVE FLOOR SHOW PIPING PLAN SHOW PIPING GRAPHIC SYMBOLS AND ABBREVIATIONS ABBREV.'' SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION A4 AMJD AMFJS AMFSS MEWS AMRD'. AMRS AMWD AR --Al— —MUD— — AMFJS— — AI4E55— —MEWS— —A4120— —AMR5— ANIMATION PIPE (4) ATLAS MAN JET DISCHARGE ATLAS MAN FEATURE JET SUCTION ATLAS MAN FEATURE SKIMMER SUCTION ATLAS MAN FEATURE WATERFALL SUCTION ATLAS MAN RECIRCULATION DISCHARGE ATLAS MAN RECIRCULATION SUCTION ATLAS MAN WATERFALL DISCHARGE AQUARIUM RETURN AS EMU_ EMLDR EMS ESS EWSD ROD RCS AS — BAWL— — EMLDR— AQUARIUM SUPPLY EXT. 14-LEVEL WATERFALL DISCHARGE (LEFT) EXT. M -LEVEL WATERFALL DISCHARGE (RIGHT) EXTERIOR MAIN SUCTION EXTERIOR SKIMMER SUCTION EXTERIOR WET SIGN DISCHARGE RAIN CURTAIN DISCHARGE RAIN CURTAIN SUCTION EMS —ESS— —EWSD— —ROD— —RCS— —MAW— —AR— CU AFF ALT AP BHP CA CD CHW CLG CO WCO GOND CD CONN CW DIFF DMPR DN DW EA EAT EF EHC EL EOPT ESP ABBREVIATIONS AIR AIR COOLED CONDENSING UNIT ABOVE FINISHED FLOOR ALTERNATE ACCESS PANEL BACK FLOW PREVENTER BRAKE HORSEPOWER COMPRESSED AIR CONDENSATE DRAIN CIRCULATING HOT WATER CEIUNG CLEANOUT WALL CLEANOUT CONDENSATE CONDENSATE DRAIN CONNECTION COLD WATER DIFFUSER DAMPER DOWN DOMESTIC WATER EXHAUST AIR ENTERING AIR TEMPERATURE EXHAUST FAN ELECTRIC HEATING COL ELEVATION EQUIPMENT EXTERNAL STATIC PRESSURE urt EXH FD FP FPI FPIA FSW GV GW N B HG H TG HUM HW LAT LOUT MAU N OA 050 OS &Y POW PD PG PLBG ENTERING WATER TEMPERATURE EXHAUST FLOOR DRAIN FIRE IEC0ON FINS PER INCH FEET PER MINUTE SWITCH GAS GATE VE GREASE WASTE HOSE B REFRIGERANT HOT GAS HUMIDIFIER HEATING HOT WATER INVERT ELEVATION REFRIGERANT UOUID LEAWNG AIR TEMPERATURE LEAVING WATER TEMPERATURE MAKE -UP AIR UNIT NECK OUTSIDE AIR OVERFLOW STORM DRAIN OUTSIDE STEM AND YOKE PROTECTED COLD. WATER (FROM RPZ -BFP) PRESSURE DROP PRESSURE GAUGE PLUMBING PRV PRVA RA REFR REG RPZ -BFP RN SA SAN SCW SD SF SP SPKLR SS 51R SUC T TRANS TSP V VD VTR WDO 'APD POW:.:? ROOF VENTILATOR PRESSURE REDUCING VALVE RETURN AIR REFRIGERANT /REFRIGERATE REGISTER REDUCED PRESS. ZONE B.F.P. ROOFTOP UNIT SUPPLY AIR SANITARY SOFTENED COLD WATER STORM DRAIN SUPPLY FAN STATIC PRESSURE SPRINKLER SANITARY SEWER STORM REFRIGERANT SUCTION THERMOSTAT TRANSFER TOTAL STATIC. PRESSURE VENT VOLUME DAMPER VENT THRU ROOF WALL CLEANWT' WATER. PRESSURE DROP CITY OF 000512/ APPROVED OCT 161996 AS NO BUILDING D0F7IIDN Redkne N. Date Desorption 201 05n St. S.E. Suite 325 Minneapolis, MN 55414 Clrungham Grob Architecture 111011w Design Planning Construction Services Telephone: 612 -379 -3400 Facsimile' 612 - 379 -4400 Internet: www.cuningham.com RAINFOREST' CAFE Southcenter Mall Tukwila, WA Shea( Ttle MECHANICAL SHEET INDEX, ABBREVIATIONS, &- SYMBOLS 0 6115 OF1UKWILA S; P 1) 293 NTPR Shed Nrtb& M000 CONSTRUCTION DOCUMENTS db. UP SEE ' = ET 1/M140 FOR WORK INSIDE THIS AREA F1XTURE''TIP HAND SINK VENT 1. CONCEAL ALL VENT PIPING IN WALLS OR TREE TRUNKS NEXT TO COLUMNS. 2. ALL PIPE SLABS THROUGH. FLOOR SHALL BE COORDINATED !WITH ROCKWORK INSTALLATION, EXTENDED TO 24'. A.F.F. AND BE CAPPED, UNLESS NOTED OTHERWISE. ALL FLOOR PENETRATIONS SHALL. BE SEALED ,WATER I1106T. 3. REFER TO OLYMPIC POOLS VENDOR SHOP DRAWINGS FOR ADDITIONAL INFORMATION. 4. VERIFY EXISTING STORM DRAIN LOCATION AND INVERT ELEVATIONS. AND REPORT ANY DISCREPANCIES TO':ENGINEER PRIOR TO STARTING WORK. 5. PORTIONS OF THE SANITARY SEWER SYSTEM ARE DESIGNED AS A COMBINATION- WASTE/VENT SYSTEM. 6.. PROVIDE A WALL CLEANOUT ON EACH VENT OF THE COMBINATION WASTE/VENT SYSTEM. 7. PROVDE ACCESSIBLE CLEANOUTS FOR THE SANITARY SEWER & GREASE WASTE UNES AS SHOWN, AND AT ALL CHANGES IN DIRECTION OVER 135'. ISEE SHEET M180 FOR KEY NOTES) EQUIPMENT SCHEDULE OUGH -114 ONLY, FINAL CONNECTIONS 5104 OUT REM IN —UNE FILTERS AND BACKFLOW PREVENTERS Comm. No RECEIVED CITY OFTUKWILA S FD 1 11998 PERMIT CENTER (s l 1 6) 7 ! (8 n UNDERFLOOR PLUMBING PLAN „R• _ P.fY NORTH ) MECHANICAL CONTRACTOR PROVIDES WATER AND GRAIN BY THE UNIT SUPPLIERS. Reggie No. Date Description Date: Ora Signet Pr *petTIs: `.. .: •♦ RAINFOREST' CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS Sleet Re aTir Cuningham Group Architecture Interior Design Planning Construction Services 201 Mom 51 S.E. Suite 325 Minneopolis, MN 55414 Telephone, 612- 379 -3400 Facsimile: 612- 379 -4400 Internet: www.cuningham.com CITY OF TUMNILA VPPNOVEO OCT 1 61998 UNDERFLOOR Ah t a e PLUMBING PLAN 0LILO5!F:i DIVISION 7/2/96 CAP115 SERVICE AREA EQUIPMENT SCHEDULE Z TYPE FIXTURE I.W. WASTE VENT CW HW 1H GAS REMARKS O .. COFFEE MAKER _ — 45" _ (r) STUB OUT +48 11 . . A.F.F. '... SIO HAND SINK — 14p" 144 . T4 N." — STUB. OUT +12' A.F.F. SI1 CARBONATOR — — — 42" — — (r) 5158 OUT +12 A.F F. S T X MIMMILIM On 0 SEE SHEET M 30. FOR WORK INSIDE THIS AREA e"_T '-- II OE 0 WI 1 �•O` ? 1 m �� 1 i o ah ��4 _ o ® _ 7.., f lkWi t ®iM ai_ ®A ® 1 ®"1®A\ NR! s ®�i711s�,{{I I ��� © . z0 � ®, © �I rr ` I 6 , 7'C°Y_ I JGI!!`.11�Dti�li il law L 1 ABOVE FLOOR PLUMBING PLAN 1/8' r "a l 10 i 11 ; ( 12 NORTH GENERAL NOTES r) MECHANICAL CONTRACTOR PRONDES WATER AND DRAIN ROUGH —IN ONLY FINAL CONNECTIONS BY THE UNIT SUPPLIERS.. 1. CONCEAL ALL VENT PIPING IN WALLS OR TREE TRUNKS NEXT TO COLUMNS. 2. ALL PIPE STUBS THROUGH FLOOR SHALL BE COORDINATED WITH ROCKWORK INSTALLATOIN. EXTENDED TO 24 A.F.F. AND BE CAPPED. UNLESS NOTED OTHERWISE. ALL FLOOR PENETRATIONS SHALL BE SEALED WATER TIGHT. 3. REFER TO OLYMPIC POOLS WATER FEATURE DRAWINGS FOR ADDITIONAL INFORMATION. 4. VERIFY EXISTING GREASE WASTE, SANITARY STUB LOCATIONS AND INVERT ELEVATIONS PRIOR TO. STARTING WORK. REPORT ANY DISCREPENCIES TO ENGINEER. 5. PROVIDE ACCESSIBLE CLEANOUTS AS SHOWN AND FOR ALL CHANGES IN DIRECTION OVER 135' SEE SHEET M160 FOR KEY. NOTES I COY OF TUI(WSA A°P202ED OCT 161993 AS NDI I 0151 02lu v P°I0N IN —UNE FILTERS AND BACKFLOW PREVENTERS Ration No. Date Description Date: Tukwila, WA Sheet Mk amt NwOer RECEIVED CITY OFTUKWILA 8E81 1 1998 PERMITCENTER M110 Curtingham Group Architecture Interior Design Planning Construction 'Services 201 Main SL 1F. Suite 325 Minneapolis, MN 55414 Telephone: 612- 379 -3400 Facsimile: 612- 379 -4400 www ningham.com Em Southcenter Mall CONSTRUCTION DOCUMENTS ABOVE FLOOR PLUMBING PLAN 7/2/98 KITCHEN EQUIPMENT SCHEDULE ITEM NO. FIXTURE TYPE I.W. WASTE VENT CW HW 0 GAS REMARKS Ki ICE MACHINES WEANS (44) - - 49' - - - (444),(4444) 51010 OUT +72" A.F.F. K4 5e' - - - - - - CONDENSATE UNE PROVIDED AND INSTALLED BY 0E1 COOLER/FREEZER K9 50MAT SYSTEM - - - - - - - 2" SLURRY OUTLET N RET., REFER TO DETAIL 7/8512 ® DISHMACHINE 2' (44) - - - - -- - 1" 180' HW TO DISHMACHINE BOOSTER HEATER ® SOILED DISH TABLE 2- ('0 - - TY 60 - - - ® 3 COMPARTMENT SINK 2" (44) - - - - - - - Il PRERINSE SPRAY 2" (44) - - Ye tY - - STUB OUT +12' A.F.F. C r (44) - - 1" 1 - - - REFRIGERATED COUNTER ® REFIOG. EQUIP. STAND (44) - - - - - - (4) 0 1 H. FOOD 3 WELL DROP-IN 1" (44) - - - - - - - K29 (44) - - - - - _ - REFRIGERATED EQUIP. STAND ® UTILITY DIST. SYSTEM - - - 1 t' - 2" LIDS PROVIDED AND INSTALLED BY DEI ® STEP UP RANGE 9 BURNERS - - - - - - 4i' (4) 0 BOOSTER HEATER - - - - - 1' - STUB OUT +12" A.F.F., REFER TO DETAIL 5/6512 0 HOT TOP, RANGE - _ _ - _ _ ITV (4) K35 60• CHARBROILER _ _ ., _ _ - 4 ' ( K36 60' GRIDDLE - _ _ _ _ _ 4' ( ® FRYER BATTERY t (4) K38 REFRIGERATED COUNTER'.. ( - - - - - - - CONVEYOR OVEN 2 DECKS - - - _ _ _ (2) ( C r CNEEZE MELTER _ _ _ _ _ _ 14- ( 0 REFRIG. SALAD COUNTER (w) _ _ t• _ _ _ - 4) 4 BURNER RANGE _ - _ _ _ _ 1• (4) K50 BRAISING PAN (a)'. - - lY Yf - H' (4) K51 DOUBLE CONVECTION OVEN - - - - - - (2) Y' (4) ® PRERINSE /ADD A FAUCET - - - 14' TY - - STUB OUT +12' A.F.F. 11: WALL MOUNTED HAND. SINK - 135 me SY 14" - - 51U8 OUT +12' A.F.F. 42 WALL MOUNTED HOSE REEL - - - T4" Ye' - - STUB OUT +42' A.F.F., REFER TO DETAIL 6/34512 MOP SINK STUB OUT +36" A.F.F. (BY G.C.) DOUBLE'. SINK (a) MOUNT FAUCET - - -. 1Y )4' - - STUB OUT +12' A.F.F. ® FLOOR TROUGHS - I3' - - - 4' -01 z F-0 (BY G.C.) PRERINSE /ADD A FAUCET - 16 /4' - 5NB OUT +12' A.F.F. HOT FOOD WELL 11 DIPPER WELL (44),4' SERVICE AREA EQUIPMENT SCHEDULE ITEM NO. FIXTURE TYPE 1.W. WASTE VENT. CW HW 180' HW 'GAS REMARKS O . . COFFEE MAKER - - - 14" - - - (#) 5TUB OUT +48• A.F.F. . 510 HAND SINK 114' 1S4 ye' Ye' - - 5168 OUT +12• A.F.F. ® CARBONATOR - 114' - (() . STUB OUT +12' A.F.F. 51J ESPRESSO MACHINE (8B) - - 14 - - - (#) STUB OUT +4B "' A.F.F. :SEE SHEET MI00 FOR WORK OUTSIDE THIS AREA CORRIDOR 1 121 , 1 ... RESTROOM UNDERFLOOR PLUMBING PLAN O KITCHEN & PUBLIC 1 1/4 _ 1 ,. 0 4 4) MECHANICAL CONTRACTOR T0' MAKE FINAL CONNECTIONS FROM 111E 0DS TO THE EQUIPMENT: CONNECTORS ARE PROVIDED WITH THE EQUIPMENT BY DEI. 44) PIPE INDIRECT. WASTES (I.W.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. THE LW. SIZE IS DETERMINED BY THE FIXTURES'. WASTE SIZE UNLESS 0159985E NOTED. MINUMUM SIZE OF INDIRECT WASTE SHALL BE V' 4 44) MECHANICAL CONTRACTOR PROVIDES WATER AND DRAIN ROUGH -IN'. ONLY. FINAL CONNECTIONS WITH IN-LINE ALTERS AND BACKFLOW. P905091ERS BY THE UNIT SUPPLIERS ( PROVIDED 8Y. ICEMAKERS AND INSTALLED BY DEI'5 EQUIPMENT INSTALLERS. MECHANICAL CONTRACTOR PROVIDES I WATER AND DRAIN ROUGH IN I ONLY. FINAL CONNECTIONS WITH IN-LINE FILTERS AND BACKFLOW PREVENTERS BY THE UNIT SUPPLIERS. i PIPE INDIRECT WASTES (I.W.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORISES. 1115. I.W. SIZE IS DETERMINED BY THE FIXTURES WASTE SIZE UNLESS OTHERWISEI NOTED. MINUMUM SIZE OF INDIRECT WASTE SHALL BE 39' KITCHEN EQUIPMENT NOTES 1. ALL KITCHEN EQUIPMENT 15 FURNISHED AND SET IN PLACE BY DEI UNLESS OTHERWISE NOTED. MECHANICAL CONTRACTOR SHALL ROUGH -IN AND CONNECT TO ALL KITHCEN EQUIPMENT AS REQUIRED BY DEI AND ALL GOVERNING AUTHORITIES. 2. KITCHEN EQUIPMENT ROUGH -IN LOCATIONS SHOWN ARE AS SCHEDULED AND 5HOWN ON THE FLOOR PLAN. FIELD VERIFY LOCATIONS WITH 0E1'5 PLANS. 3. SINK FAUCETS ARE FURNISHED BY DEI. MECHANICAL CONTRACTOR SHALL INSTALL AND MAKE FINAL CONNECTIONS. 4. ALL PIPING REQUIRED TO RUN AT UNDERSIDE OF COUNTERS SHALL BE INSTALLED AS APPROVED AND DIRECTED BY DEI. NO MECHANICAL PIPING SHALL INTERFERE WITH EQUIPMENT OPERATION OR MAINTENANCE. 5. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL, UNLESS NOTED TO BE SUPPLIED BY DEI, ALL NECCESSARY 'P' TRAPS, BACKFLOW P951061ER5, SHOCK ABSORBERS. PRESSURE REDUCING VALVES, GAS PRESSURE REGULATORS. VACUUM BREAKERS. AND APPURTENCES AS REQUIRED BY ALL CODES AND GOVERNING AUTHORISES FOR EQUIPMENT CONNECTIONS. 6. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL SHUT -OFF VALVES AND UNION5 AT EACH KITCHEN ITEM REQUIRING WATER OR GAS CONNECTIONS. ALL SHUT -OFF VALVES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS. 7. ALL. EXPOSED PIPING THROUGH KITCHEN FLOOR (WASTE, WATER. OR GAS) SHALL BE INSTALLED WITHIN PIPE SLEEVES BY MECHANICAL CONTRACTOR. SEAL SLEEVES WATERTIGHT AT FLOOR UNE. BETWEEN SLEEVE AND PIP E RISER 'SEAL NTH "THIOKOL" SEALANT. PIPE SLEEVES SHALL BE Ye (MAXIMUM) LARGER THAN PIPE RISER OR PIPE INSULATION. 8. ALL INDIRECT WASTE PIPE (LW.) AND EQUIPMENT DRAIN LINES SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR UNLESS NOTED OTHERWISE. ROUTE WASTE PIPING BELOW COUNTERS OR EQUIPMENT AS APPROVED AND DIRECTED BY OE. PIPE INDIRECT WASTES OVER TO THE NEAREST. FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. MINIMUM SIZE OF INDIRECT WASTE SHALL BE W. 9. ALL EXPOSED PIPING SHALL BE CHROME PLATED. 10. INSTALL QUICK DISCONNECTS, GAS PRESSURE REGULATORS AND FLEXIBLE GAS HOSES FOR KITCHEN EQUIPMENT FURNISHED WITH EQUIPMENT. GENERAL NOTES 1. REFER TO, DEI'S DRAWINGS FOR FURTHER INFORMATION AND EXACT ROUGH -IN REGUIRMENTS. NOTIFY ENGINEER OF ANY DISCREPANCIES BEFORE STARTING WORK. 2. THE FLOOR SHALL BE SLOPED AT 1:50 TO ALL FLOOR DRAINS. 3. THE KITCHEN GREASE WASTE SYSTEM HAS BEEN DESIGNED AS A. COMBINATION WASTE/VENT SYSTEM. 4. PORTIONS OF THE SANITARY SEWER SYSTEM ARE DESIGNED AS A. COMBINATION. WA51E/VENT. SYSTEM, 5. PROVIDE A WALL CLEANOUT ON EACH VENT OF THE COMBINATION WASTE/VENT SYSTEM. 6. PROVIDE ACCESSIBLE CLEANOUTS FOR THE SANITARY SEWER k GREASE WASTE UNES AS SHOWN, AND AT ALL CHANGES IN DIRECTION OVER 1355 I SEE SHEET M180 FOR KEY NOTES I CITY OF TUIN A APPROVED OCT 161593, A .r TO OL LDI 2 Cunilgham Crop Architecture Interior Design Planning Construction Services 201 Main 5t. 5.E. Suite 325 Minneapolis, MN 55414 Telephone: 612- 379 -3400 Facsimile: 612- 379 -4400 Internet: www.caningham.com Oats: Comm. NE 7/2/80 CAP115 5gn Dote: Reg. No. Prefect The -RAINFOREST CAFE Southcenter Mall Tukwila, WA . CONSTRUCTION DOCUMENTS Sleet The KITCHEN & PUBLIC RESTROOM UNDERFLOOR PLUMBING PLAN REOEIV52 env 001417+1LA S EP 11 Y293 PERMITCENTER Sheet Nnber M120 ' KITCHEN EQUIPMENT SCHEDULE ITEM NO. FIXTURE TYPE I.W. WASTE VENT CW HW 180' GAS REMARKS KI ICE MACHINES W/BINS (..) - - 49" - - - (.a),(w.) STUB OUT +72 A.F.F. K4 COOLER/FREEZER Y" - - - - - - CONDENSATE UNE PRONGED AND INSTALLED BY DEI K9 SOMAT SYSTEM - - - - - - - Y SLURRY OUTLET & RET.. REFER TO DETAIL 7/14512 ® DISHMACHINE 2" (..) - - - - 1" ul�ro� 1" 180' HW TO DISHMACHINE BOASTER HEATER ® SOILED DISH TABLE 2' (a) - - 1y- 1y - - - ® 3 COMPARTMENT SINK 2" (..) _ J . J ] O PRERINSE SPRAY 2° (..) - - yr Ys" - - STUB OUT +12" A.F.F. ® REFRIGERATED COUNTER (..) 1" 1" - - ® REFRIG. EQUIP. STAND (..) - - - - - - (.) e . H. F000 3 WELL DROP -IN 1" («) - - - - - - - O REFRIGERATED EQUIP. STAND (..) - - - - - - _ ® UI1UTY DIST. SYSTEM - 1.' 1" 1" 2` LADS PROVIDED MID INSTALLED BY DEI ® STEP UP RANGE 9 BURNERS - - - - - - 3'" (.) 0 BOOSTER HEATER - - - - - 1 - STUB OUT +12" A.F.F.. REFER TO DETAIL 5/6512 0 HOT TOP RANGE - - - - - - 111." (.) K35 60" CHARBROILER - - - - - - 13" (.) K36 60° GRIDDLE - - - - - - F ( ® FRYER BATTERY _ _ _ - _ _ p (•) K3B ■ REFRIGERATED COUNTER (33) - - - - - - - K39 CONVEYOR OVEN 2 DECKS - - - - ' - - (2) 4i" (.) K CHEEZE MELTER _ _ _ _ _ - y,- ( ® REFRIG. SALAD COUNTER (w) _ _ 1 ' _ _ - - K4B 4 BURNER RANGE - - - - - - 1" (.) 0 BRAISING PAN (..) - - 14 14 - lY (3) ® DOUBLE CONVECTION OVEN - - - - - - (2) 17' (.) PRERINSE /ADD A FAUCET - - - y" q - - STUB OUT +12' A.F.F. 0 WALL MOUNTED HAND SINK - 115" 11' LY VA" - - STUB OUT +12" A.F.F. 0 WALL MOUNTED HOSE REEL - - - Vs" 1Y - - STUB OUT +42" A.F.F., REFER TO DETAIL 6/6512 MOP SINK - 3" F.D. - 6i" R4" - - STUB OUT +36" A.F.F. (BY G.C.) DOUBLE SINK (..) - - t r - - - - MOUNT FAUCET n I 11 ■ I'I. PARIMIrV LN / 9cx ba�.�� � abxb ® I :roll STUB OUT +12" A.F.F. 0 FLOOR TROUGHS - 3' - - _ ,. _ - 4'-01 x 1' -0 (BY G.C.) ® PRERINSE/ADD A FAUCET 1� - - 1Y 14' - - &us OUT +12" A.F.F. e HOT FOOD WELL 1 "(w) - - - - - - K86 DIPPER WELL (m) _. - SERVICE AREA EQUIPMENT SCHEDULE ITEM NO. FIXTURE TYPE I.W. WASTE VENT CW HW T 8C 80' HW GAS REMARKS 55 COFFEE MAKER 0. - - t4"' - - (9) STUB OUT +48" A.F.F. HAND SINK - 1N IVs 1£' 14' - - STUB OUT +12" A.F.F. 511 CARBONATOR - - - 14" - - (9) STUB OUT +12" A.F.F. 513 ESPRESSO MACH1NE (#/) N ul�ro� (9). STUB OUT +48" A.F.F. KITCHEN & PUBLIC RESTROOM UNDERFLOOR PLUMBING CO ' = , ' -O' , 3) MECHANICAL CONTRACTOR TO MAKE FINAL CONNECTIONS FROM THE UDS TO THE EQUIPMENT. CONNECTORS ARE PROVIDED VA1H THE EQUIPMENT BY DEI. ..) PIPE INDIRECT WASTES (LW.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. THE I.W. SIZE IS DETERMINED BY THE FIXTURES WASTE SIZE UNLESS OTHERWISE NOTED. MINUMUM SIZE OF INDIRECT WASTE. SHALL BE 04" Am) MECHANICAL CONTRACTOR PROVIDES WATER AND DRAIN ROUGH -IN ONLY FINAL CONNECTIONS MIN IN -UNE FILTERS AND BACKFLOW P904091ERS BY THE UNIT SUPPLIERS (.n.) PROVIDED BY ICEMAKERS AND INSTALLED BY DO EQUIPMENT INSTALLERS. MECHANICAL CONTRACTOR PROVIDES WATER AND DRAIN ROUGH -19 ONLY. FINAL CONNECTIONS WITH IN -UNE FILTERS AND. BACKFLOW PREVENTERS BY THE UNIT SUPPLIERS I PIPE INDIRECT WASTES (I.W.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES THE I.W. SIZE IS DETERMINED BY THE FIXTURES WASTE SIZE UNLESS OTHERWISE NOTED. MINUMUM SIZE OF INDIRECT WASTE 'SHALL 86 s KITCHEN EQUIPMENT NOTES 1. ALL KITCHEN EQUIPMENT 15 FURNISHED AND SET IN PLACE BY DO UNLESS OTHERWISE NOTED. MECHANICAL CONTRACTOR SHALL ROUGH -IN AND CONNECT TO ALL KIIHCEN EQUIPMENT AS REQUIRED BY DO AND ALL GOVERNING AUTHORITIES. 2. KITCHEN EQUIPMENT ROUGH -IN LOCATIONS 51400N ARE AS SCHEDULED AND SHOWN ON THE FLOOR PLAN. FIELD VERIFY LOCATIONS WITH DEI'5 PLANS. 3. SINK FAUCETS ARE FURNISHED BY DEI. MECHANICAL CONTRACTOR SHALL INSTALL AND MAKE FINAL CONNECTIONS. ALL PIPING REQUIRED TO RUN AT UNDERSIDE OF COUNTERS SHALL BE INSTALLED AS APPROVED AND DIRECTED BY DEI. NO MECHANICAL PIPING SHALL INTERFERE WITH EQUIPMENT OPERATION OR MAINTENANCE. 5. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL, UNLESS NOTED TO BE SUPPLIED BY DEI, ALL NECCESSARY P' TRAPS, BACKFLOW PREVENIERS, SHOCK ABSORBERS, PRESSURE REDUCING VALVES. GAS PRESSURE REGULATORS. VACUUM BREAKERS, AND APPURTENCES AS REQUIRED BY ALL CODES AND GOVERNING AUTHORITIES FOR EQUIPMENT CONNECTIONS. 6. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL SHUT -OFF VALVES AND UNIONS AT EACH KITCHEN ITE14 REQUIRING WATER OR GAS CONNECTIONS. ALL SHUT -OFF VALVES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS. 7. ALL EXPOSED PIPING THROUGH KITCHEN FLOOR (WASTE, WATER, OR GAS) SHALL BE INSTALLED 1101119 PIPE SLEEVES BY MECHANICAL CONTRACTOR. SEAL SLEEVES WATERTIGHT AT FLOOR LINE. BETWEEN SLEEVE AND PIP E RISER SEAL WITH "THIOKOL" SEALANT. PIPE SLEEVES SHALL BE 15" (MAXIMUM) LARGER THAN PIPE RISER OR PIPE INSULATION. 8. ALL INDIRECT WASTE PIPE (I.W.) AND EQUIPMENT DRAIN LINES SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR UNLESS NOTED OTHERWISE. ROUTE WASTE PIPING BELOW COUNTERS OR EQUIPMENT AS APPROVED AND DIRECTED BY DEI. PIPE INDIRECT WASTES OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. MINIMUM SIZE OF INDIRECT WASTE SHALL BE 44 ". 9. ALL EXPOSED PIPING SHALL BE CHROME PLATED. 10. INSTALL QUICK DISCONNECTS. GAS PRESSURE REGULATORS AND FLEXIBLE GAS HOSES FOR KITCHEN EQUIPMENT FURNISHED WITH EQUIPMENT. GENERAL NOTES 1. REFER TO DO'S DRAWINGS FOR FURTHER INFORMATION AND EXACT ROUGH -I9 REQUIRMENTS. NOTIFY ENGINEER OF ANY DISCREPANCIES BEFORE STARTING WORK. 2. THE FLOOR SHALL BE SLOPED AT 1:50 TO ALL FLOOR DRAINS. 3. THE KITCHEN GREASE WASTE 5YSIEM. HAS BEEN DESIGNED AS A COMBINATION WASTE/VENT SYSTEM 4. P0R110NS OF THE SANITARY SEWER. SYSTEM. ARE DESIGNED: AS A. COMBINATION WASTE/VENT SYSTEM. 5. PROVIDE A' WALL CLEANOUT ON EACH VENT OF THE COMBINATION WASTE/VENT SYSTEM. 6. PROVIDE ACCESSIBLE CLEANOUTS FOR DIE SANITARY SEWER & GREASE WASTE UNES AS SHOWN, AND AT ALL CHANGES IN DIRECTION OVER 1350 SEE SHEET M160 FOR KEY NOTES 8361069 Oil' No. Oats Description Date: Gamin. Na. NORTH PLAN Cil' OF TUI(WILA APPROVED OCT 1 8 1(93 trDIED , BUILDING EVICI34) Cunirgham Group Architecture Interior Design Planning Construction Services 201 Main St. S.E. Suite 325 Minneapolis. MN 55414 Telephone: 612- 379 -3400 Facsimile: 612 - 379 -4400 Internet: www.cuningham.con, R P 1 g a1eC( The RAINFOREST CAFE Southcenter Mall Tukwila, WA Shed The Shed Nlttber M130 7/2/98 CAP115 CONSTRUCTION DOCUMENTS KITCHEN & PUBLIC RESTROOM ABOVE FLOOR PLUMBING PLAN R I GE'VED. cnv o LICWILA SEP 1 1 1998 PFRMITCFNTER • I . 0. z• izv.• _tom - �'� . \ 0 ; 1. _ ul�ro� limun■, c. _ J . J ] ., H lit 111 -_1Y" \vim 0 1 10° 3• 1 - - Y i K63 ® 471) 180' SHW I 180'CHW O V .",..' 120' SHW , ►i 1 1_I' lira i , 1• 2, I^ 215• _ " ;r— 1.' ! . 2" __ � j6' pie - Imilu I ►rte m ai 1 ° II 6 A. ' Cil ! ��i I 1) � r Reg I 111.11011:111 AI m r A�1 !m i --....i, _ ° ����1`^�\\O i1 ill IlL 1 ` 1 ) '. — I II 13 4 \] ® \ \ 11 i il I -1 ryi KA )1 I�I — • Q1 II 11[� H s ®nn Vi�e... ,I■I11111 MA MEM ] 11 I � i. 9 ' ^. I MI 234' ^ 6r .,iL r M1.10 .001 + 1 iI 0 We o . - M 2" G "1E4 I 111■ CW 120' SHW ® ■ MII_i` 711/2" V ., = �� t r a• eN .O I 11 ■ I'I. PARIMIrV LN / 9cx ba�.�� � abxb ® I :roll 1 f • In, ! I Y" ell I I mil -- K4 \ 1� e r iee7 EI S. E Bbxtae 4" imma I a. MillIPAINSEINI fI � N -// E MH „.081 K4 I.”' n \ , \ „ 4 0 Q ® I e 111 $ ' e� Eireargargi KITCHEN �� :� .. 11111 ®1 i nn I I I ;� � I F . TI 11 I O —4,— Ka 2/z �I / p MI DI. _ \ I� ° ® Emil 9( 9( Li g( 11/2 P ° ® $ � f y 114' 114 11h 4" 21" 0 ® ' Wilk.. . ° ,, SEE SHEET M 110 FOR WORK OUTSIDE'. THIS AREA % 9f x ®rw 1 ”1 IIMMIFIIIPar 9c x la ..:. v! a• I 01 ' ® I - 9pR�INI+b7B+ O RRIDOR 1 • ' 1 ���I ® 1 121 1 • . KITCHEN & PUBLIC RESTROOM UNDERFLOOR PLUMBING CO ' = , ' -O' , 3) MECHANICAL CONTRACTOR TO MAKE FINAL CONNECTIONS FROM THE UDS TO THE EQUIPMENT. CONNECTORS ARE PROVIDED VA1H THE EQUIPMENT BY DEI. ..) PIPE INDIRECT WASTES (LW.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. THE I.W. SIZE IS DETERMINED BY THE FIXTURES WASTE SIZE UNLESS OTHERWISE NOTED. MINUMUM SIZE OF INDIRECT WASTE. SHALL BE 04" Am) MECHANICAL CONTRACTOR PROVIDES WATER AND DRAIN ROUGH -IN ONLY FINAL CONNECTIONS MIN IN -UNE FILTERS AND BACKFLOW P904091ERS BY THE UNIT SUPPLIERS (.n.) PROVIDED BY ICEMAKERS AND INSTALLED BY DO EQUIPMENT INSTALLERS. MECHANICAL CONTRACTOR PROVIDES WATER AND DRAIN ROUGH -19 ONLY. FINAL CONNECTIONS WITH IN -UNE FILTERS AND. BACKFLOW PREVENTERS BY THE UNIT SUPPLIERS I PIPE INDIRECT WASTES (I.W.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES THE I.W. SIZE IS DETERMINED BY THE FIXTURES WASTE SIZE UNLESS OTHERWISE NOTED. MINUMUM SIZE OF INDIRECT WASTE 'SHALL 86 s KITCHEN EQUIPMENT NOTES 1. ALL KITCHEN EQUIPMENT 15 FURNISHED AND SET IN PLACE BY DO UNLESS OTHERWISE NOTED. MECHANICAL CONTRACTOR SHALL ROUGH -IN AND CONNECT TO ALL KIIHCEN EQUIPMENT AS REQUIRED BY DO AND ALL GOVERNING AUTHORITIES. 2. KITCHEN EQUIPMENT ROUGH -IN LOCATIONS 51400N ARE AS SCHEDULED AND SHOWN ON THE FLOOR PLAN. FIELD VERIFY LOCATIONS WITH DEI'5 PLANS. 3. SINK FAUCETS ARE FURNISHED BY DEI. MECHANICAL CONTRACTOR SHALL INSTALL AND MAKE FINAL CONNECTIONS. ALL PIPING REQUIRED TO RUN AT UNDERSIDE OF COUNTERS SHALL BE INSTALLED AS APPROVED AND DIRECTED BY DEI. NO MECHANICAL PIPING SHALL INTERFERE WITH EQUIPMENT OPERATION OR MAINTENANCE. 5. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL, UNLESS NOTED TO BE SUPPLIED BY DEI, ALL NECCESSARY P' TRAPS, BACKFLOW PREVENIERS, SHOCK ABSORBERS, PRESSURE REDUCING VALVES. GAS PRESSURE REGULATORS. VACUUM BREAKERS, AND APPURTENCES AS REQUIRED BY ALL CODES AND GOVERNING AUTHORITIES FOR EQUIPMENT CONNECTIONS. 6. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL SHUT -OFF VALVES AND UNIONS AT EACH KITCHEN ITE14 REQUIRING WATER OR GAS CONNECTIONS. ALL SHUT -OFF VALVES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS. 7. ALL EXPOSED PIPING THROUGH KITCHEN FLOOR (WASTE, WATER, OR GAS) SHALL BE INSTALLED 1101119 PIPE SLEEVES BY MECHANICAL CONTRACTOR. SEAL SLEEVES WATERTIGHT AT FLOOR LINE. BETWEEN SLEEVE AND PIP E RISER SEAL WITH "THIOKOL" SEALANT. PIPE SLEEVES SHALL BE 15" (MAXIMUM) LARGER THAN PIPE RISER OR PIPE INSULATION. 8. ALL INDIRECT WASTE PIPE (I.W.) AND EQUIPMENT DRAIN LINES SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR UNLESS NOTED OTHERWISE. ROUTE WASTE PIPING BELOW COUNTERS OR EQUIPMENT AS APPROVED AND DIRECTED BY DEI. PIPE INDIRECT WASTES OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. MINIMUM SIZE OF INDIRECT WASTE SHALL BE 44 ". 9. ALL EXPOSED PIPING SHALL BE CHROME PLATED. 10. INSTALL QUICK DISCONNECTS. GAS PRESSURE REGULATORS AND FLEXIBLE GAS HOSES FOR KITCHEN EQUIPMENT FURNISHED WITH EQUIPMENT. GENERAL NOTES 1. REFER TO DO'S DRAWINGS FOR FURTHER INFORMATION AND EXACT ROUGH -I9 REQUIRMENTS. NOTIFY ENGINEER OF ANY DISCREPANCIES BEFORE STARTING WORK. 2. THE FLOOR SHALL BE SLOPED AT 1:50 TO ALL FLOOR DRAINS. 3. THE KITCHEN GREASE WASTE 5YSIEM. HAS BEEN DESIGNED AS A COMBINATION WASTE/VENT SYSTEM 4. P0R110NS OF THE SANITARY SEWER. SYSTEM. ARE DESIGNED: AS A. COMBINATION WASTE/VENT SYSTEM. 5. PROVIDE A' WALL CLEANOUT ON EACH VENT OF THE COMBINATION WASTE/VENT SYSTEM. 6. PROVIDE ACCESSIBLE CLEANOUTS FOR DIE SANITARY SEWER & GREASE WASTE UNES AS SHOWN, AND AT ALL CHANGES IN DIRECTION OVER 1350 SEE SHEET M160 FOR KEY NOTES 8361069 Oil' No. Oats Description Date: Gamin. Na. NORTH PLAN Cil' OF TUI(WILA APPROVED OCT 1 8 1(93 trDIED , BUILDING EVICI34) Cunirgham Group Architecture Interior Design Planning Construction Services 201 Main St. S.E. Suite 325 Minneapolis. MN 55414 Telephone: 612- 379 -3400 Facsimile: 612 - 379 -4400 Internet: www.cuningham.con, R P 1 g a1eC( The RAINFOREST CAFE Southcenter Mall Tukwila, WA Shed The Shed Nlttber M130 7/2/98 CAP115 CONSTRUCTION DOCUMENTS KITCHEN & PUBLIC RESTROOM ABOVE FLOOR PLUMBING PLAN R I GE'VED. cnv o LICWILA SEP 1 1 1998 PFRMITCFNTER BAR EQUIPMENT SCHEDULE ITEM NO. FIXTURE TYPE I.W. WASTE VENT CW HW HW GAS REMARKS WALL MOUNTED HAND SINK - :=" CRYING ...A - STUB OUT +12' A.F.F. ® ICE BIN 1.) - i / 0 / SEE SHEET M100 FOR WORK OUTSIDE THIS AREA p\s 0 BLENDER STATION 24" (.1 - 0 <5) 4:) Ai OF * irwi .. 1,,,,t7,--,,,, EN --: it. j■ / \ ',. 1 47-losommisra AEA vir - STUB OUT +12" A.F.F. ® ICE BIN 1.) - - - SR, AH - 0.. A (ID DRAIN TRAY 1.) - Al WS 1PP= V-Will 11 - - .0. 3 COMPARTMENT SINK (L.) - 21 - STUB OUT +12" A.F.F. C . SLUSH 'ACME - - 1..) e CARBONATOR ½ (.) STUB OUT +12' A.F.F. 1 BAR UNDERFLOOR PLUMBING PLAN 1/4' = 1-0' 0 NORTH *) PIPE INDIRECT WASTES (I.W.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. THE I.W. SIZE 15 DETERMINED BY THE FIXTURES WASTE SIZE UNLESS OTHERWISE NOTED MINUMUM SIZE OF INDIRECT WASTE SHALL BE 49 .) MECHANICAL CONTRACTOR PROADES WATER AND DRAIN ROUGH IN ONLY FINAL CONNECTIONS WITH IN-UNE FILTERS AND BACI<FLOW PREVENTERS BY THE UNIT SUPPLIERS. 613.....D1 ( 1----- yr 5- GENERAL NOTE 1. REFER TO 001S SHEETS P9 & P10 FOR FURTHER INFORMATION AND EXACT ROUGH-IN REOUIRMENTS. NOTIFY ENGINEER OF ANY DECREPANCIES BEFORE STARTING WORK. 2. PORTIONS OF THE SANITARY SEWER SYSTEM ARE DESIGNED AS A COMBINATION WASTE/VENT SYSTEM. 3. PROVIDE A WAII CLEANOUT ON EACH VENT OF THE COMBINATION WASTE/VENT SYSTEM. 4. PROVIDE ACCESSIBLE CLEANOUTS FOR THE SANITARY SEVIER & GREASE WASTE LINES AS SHOWN, AND AT ALL CHANGES IN DIRECTION OVER 135. SEE SHEET M180 FOR KEY NOTES I 10 ,,--<, .--!,-....-- ,,Y 4r-41/2" 0.- • ,;% SEE SHEET MVO // O FOR • WORK OUTSIDE THIS AREA r7". '(•\ 54 101 j BAR ABOVE FLOOR PLUMBING PLAN 1/4" = B22 0 NORTH . 0 0 al> miTormw Iliet"-l" nfM w ilte 1- ) 0)- CITY OF T54/ILA APPROVED OCT 16 islaa 61.11E5T9XiT2TiFii395 Relsions No. Date DescrBtion Date Comm. Na. RAINFOREST - CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS BAR UNDERFLOOR & ABOVE FLOOR PLUMBING PLAN rIKEIVO CRY OF SEP 1 1 Sheaf Minter Cuningham Group Architecture Interior Design Planning Construction Services 20I Main St SE. Suite 325 Minneapolis, MN 55414 Telephone: 612-309-3400 Facsimile: 612-379-4400 Internet: www.coningham.com PERMIT:CENTER M140 7/2/98 - -, - ----g-,---' :=" CRYING ...A ------- T I _,_- ' -1 loa i / 0 / SEE SHEET M100 FOR WORK OUTSIDE THIS AREA p\s , \ BAR I 101 1 0 <5) 4:) Ai OF * irwi .. 1,,,,t7,--,,,, EN --: it. j■ / \ ',. 1 47-losommisra AEA vir 0 Ass SR, AH - 0.. A at = ' 10161116 Al WS 1PP= V-Will 11 - -- 21 - 0 ...—..■.. . 43 7....... . 0 I .. 1 BAR UNDERFLOOR PLUMBING PLAN 1/4' = 1-0' 0 NORTH *) PIPE INDIRECT WASTES (I.W.) OVER TO THE NEAREST FLOOR SINK AS APPROVED BY ALL GOVERNING AUTHORITIES. THE I.W. SIZE 15 DETERMINED BY THE FIXTURES WASTE SIZE UNLESS OTHERWISE NOTED MINUMUM SIZE OF INDIRECT WASTE SHALL BE 49 .) MECHANICAL CONTRACTOR PROADES WATER AND DRAIN ROUGH IN ONLY FINAL CONNECTIONS WITH IN-UNE FILTERS AND BACI<FLOW PREVENTERS BY THE UNIT SUPPLIERS. 613.....D1 ( 1----- yr 5- GENERAL NOTE 1. REFER TO 001S SHEETS P9 & P10 FOR FURTHER INFORMATION AND EXACT ROUGH-IN REOUIRMENTS. NOTIFY ENGINEER OF ANY DECREPANCIES BEFORE STARTING WORK. 2. PORTIONS OF THE SANITARY SEWER SYSTEM ARE DESIGNED AS A COMBINATION WASTE/VENT SYSTEM. 3. PROVIDE A WAII CLEANOUT ON EACH VENT OF THE COMBINATION WASTE/VENT SYSTEM. 4. PROVIDE ACCESSIBLE CLEANOUTS FOR THE SANITARY SEVIER & GREASE WASTE LINES AS SHOWN, AND AT ALL CHANGES IN DIRECTION OVER 135. SEE SHEET M180 FOR KEY NOTES I 10 ,,--<, .--!,-....-- ,,Y 4r-41/2" 0.- • ,;% SEE SHEET MVO // O FOR • WORK OUTSIDE THIS AREA r7". '(•\ 54 101 j BAR ABOVE FLOOR PLUMBING PLAN 1/4" = B22 0 NORTH . 0 0 al> miTormw Iliet"-l" nfM w ilte 1- ) 0)- CITY OF T54/ILA APPROVED OCT 16 islaa 61.11E5T9XiT2TiFii395 Relsions No. Date DescrBtion Date Comm. Na. RAINFOREST - CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS BAR UNDERFLOOR & ABOVE FLOOR PLUMBING PLAN rIKEIVO CRY OF SEP 1 1 Sheaf Minter Cuningham Group Architecture Interior Design Planning Construction Services 20I Main St SE. Suite 325 Minneapolis, MN 55414 Telephone: 612-309-3400 Facsimile: 612-379-4400 Internet: www.coningham.com PERMIT:CENTER M140 7/2/98 4" SANITARY SEWER SEE M100 FOR CONTINUATION 3 VENT • SEE M110 FOR CONTINUATION mq e -orp+ 4 SANITARY - 3 ° SE:VER'. SEE 9100 .1 FOR CONTINUATION 149" VENT 0.0. SEE 9110 FOR CONTINUATION 3" VENT SEE 9110 FOR CONTINUATION O PUBLIC TOILET WASTE AND VENT RISER DIAGRAM 2 NOT TO SCALE 1Va" SOFTENED TEMPERED (95) HOT WATER SEE 9110 FOR CONTINUATION 114' 2 COLD WATER SEE 9110 FOR CONTINUATION/ W 95 SHOCK ABSORBER P4 SHOCK p2 ABSORBER C PUBLIC TOILET PLUMBING RISER DIAGRAM NOT TO SCALE CITY OF '00WILh 02200222 OCT 161993 l.. ■LL) B ILD@IG GM3;ON No. Date Desuption Comm. No Sheet The Sheet Number RE00400D CITY OF1LIO19LA SEP 1 1 1•' PERMIT CENTER 201 Main St. S.E. Suite 325 Minneopdis. MN 55414 Telephone: 612 -379 -3400 Facsimile: 612- 379 -4400 Internet: www- cuningham_cam RAINFOREST CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS PUBLIC RESTROOMS P RISER AN M150 Cuningham Group Architecture Interior Design Planning Construction SeMCes 7/2/98 CAPIl5 KEY NOTES FOR SHEET MI10 KEY NOTES FOR SHEET M120 KEY NOTES FOR SHEET M130 114" VENT (V) DOWN. SEE 14100 FOR CONTINUATION. • 2' VENT (V) DOWN. SEE 8100 FOR CONTINUATION. • 3" VENT (V) DOWN. SEE M100 FOR CONTINUATION. 4 ROUTE 2" /115 SLUR RY OUTLET & SLURRY RETURN PIPING ABOVE THE CEILING. SEE DETAIL 7 1" REDUCED PRESSURE ZONE BACKFLOW PREVENTER RPZ -1 VALVED AND CAPPED PROTECTED COLD WATER (PCW) UNE. MOUNT ON WALL AT 5' -0" A.F.F. THE • RELEIF PORTION OF 111E REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE PIPED TO THE NEAREST FLOOR DRAIN. MAKE FINAL CONNECTIONS TO MEE FOG'S SYSTEM PER MEE FOG'S DIRECTION, ONE CONNECTION POINT. iH" REDUCED PRESSURE ZONE BACKFLOW PREVENTER RPZ -2. VALVED AND CAPPED PROTECTED COLD WATER (PCW) LINE. MOUNT ON WALL AT 5 -0' A.F.F. THE O RELIEF PORTION OF THE REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE PIPED TO THE NEAREST FLOOR DRAIN. MAKE FINAL CONNECTIONS TO OLYMPIC POOLS SYSTEM AS INDICATED ON WATER FEATURE VENDOR SHOP DRAWING l/W600, FOUR (4) CONNECTION POINTS. 1" REDUCED PRESSURE ZONE BACKFLOW P814081ER RPZ -3, VALVED AND CAPPED PROTECTED COLD WATER (PCW) UNE. MOUNT ON WALL AT 5' -0" A.F.F. THE • RELIEF PORTION OF THE REDUCED PRESSURE BACKFLOW Hi := VENTER SHALL BE PIPED TO THE NEAREST FLOOR DRAIN. MAKE FINAL CONNECTION TO ICM'S UNIT PER (CM'S DIRECTION, ONE CONNECTION POINT. O 1' COD WATER (CW) DOWN TO FLUSH VALVE (P17) FOR FLUSHING FLOOR SINK SINK (052). B ROUTE 4A' 120' SOFTENED HOT WATER (120' SHW) AND § " COLD WATER (CW) 0515 DOWN TO WASHDOWN 5TA110N (P18). INSTALL VALVE FOR (P10) ON WALL OUTSIDE OF SHOWER STALL AND PIPE FROM • VALVE TO BOTH SHOWER HEADS ON OPPOSITE SIDES OF SHOWER. SEE ARCHITECTURAL PLANS FOR MOUNTING HEIGHTS. Ya PROTECTE0 COLD WATER (PCW) DOWN IN WALL TO HOSE 81BB (P15) CONCEALED • IN ROCKWORK. COORDINATE WITH ROCKWORK INSTALLER. SEE OLYMPIC POOLS VENDOR SHOP DRAWING W301. DETAIL 9/8301 FOR MORE INFORMATION. Y' PROTECTED COLD WATER (PCW) 00551 IN WALL TO HOSE B18B (P15) CONCEALED • IN ROCKWORK. COORDINATE WITH ROCKWORK INSTALLER. SEE OLYMPIC POOLS VENDOR SHOP ORAWING W500, DETAIL 7/W500 FOR MORE INFORMATION. MOUNT TRAP PRIMER (P18) IN BASE 01: VIGNETTE, RAIN CURTAIN, OR TREE. • ROUTE PROTECTED COLD WATER (PCW) PRIMER UNES UNDERFLOOR TO FLOOR DRAINS (FD2) SHOWN ON M100. ROUTE 1 PROTECTED COLD WATER (PCW) DOWN IN TREE T0. 'CROCODILE POND." • PROVIDE 1" 9LLCOCK CONCEALED IN 800000RK. COORDINATE 98111 000000RK INSTALLER. 1 2' X C TUR OLD REQUE5 WATER (CW) IRED DO WN IN PLUMBING CHASE. CONNECT TO PLUMBING Fl A5 16 ' TO 9 PLUMBI 5' SOFNG 0XTENED TUR ES A5 RE WATER (95' QUIRD. E5HW) DOWN IN PLUMBING CHASE. CONNECT 1 3' WATER MAIN, MOUNT WATER ME AT 15' - A. 0 I 111LTRATION ROOM. COORDINATE REMOTE READER TER LOCATION 0 " WIT LANDLORE D. FI 18 DE T T 3/815 (V) UP 10. 'M THROUGH ROOF. SEE DRANG 8300 FOR CONTINUATION & O THERMOSTATIC MIXING VALVE (P19) FOR PUBLIC TOILETS. PROVIDE ISOLATION OT VALVES AND FULL SIZE VALVE BY -PASS. REFER TO SHEET 10/M510 FOR WATER HEATER DETAIL. ® V TRERMOS AND TAIIC FULL MIXIN ZE V VALVALVE E (PBY 20) 108 -PASS. EMPLOYEE TOILETS. PROVIDE ISOLATION ALVES • WATER SOFTENER DROPS & BY -PASS. SEE DETAIL 7/M510. ® REFER TO SHEET 10/4510 FOR WATER HEATER DETAIL ® 1 TO 11' PLUMBING FIXTURE 95' SOFTENED S A T W5 ATEREQUIRER (95' D. 589) DOWN IN PLUMBING CHASE. CONNECT • 11/2" VENT (V) UP. SEE 8130 FOR CONTINUATOR. O 3' VENT (V) UP. SEE 0130 FOR CONTINUATION. • 4" VENT (V) UP. SEE M130 FOR CONTINUATION. EXISTING STORM DRAIN (5D). FIELD VERIFY INVERT ELEVATION AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE STARTING WORK. O EXISTING SANITARY SEWER (55). FlEID VERIFY INVERT ELEVATION AND REPORT ANY PROBIEM5 TO THE ENGINEER BEFORE STARTING WORK. O CONNECT TO EXISTING 4' SANITARY SEWER (55). FIELD VERIFY INVENT ELEVATION AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE STARTING WORK. O CONNECT TO EXISTING 8' SANITARY SEWER (55). FIELD VERIFY INVERT ELEVATION AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE STARTING WORK. • 11/2' VENT (V) DOWN. SEE 11120 FOR CONTINUATION. • 3° VENT (V) DOWN. SEE 84120 FOR CONTINUATION. O 4" 'Waif (V) DOW SEE M120 FOR CONTINUATION. O PROYeTE 1" POTEED 1OLD WATER (PCW LINE TO 005, ORE PROTECTION O 515110. MJST CT A LOCK VALVE FURNISHED BY CAP0VEAIR OD NTA WATER e (08)) & 1" 120' S OFTEN HOT WATER (120' SHW) GWN, HORIZOL P�IG BELOW COUNT AN2 ED BEHIND EQUIPMENT TO FIXTU ROUTE O 1" 1 6 1' COD WATER (CW) 0009. ROUTE HORIZONTAL PIPING BELOW COUNTER AND 6X310!9 101011041'.0 FIXTURES 7 1" 180 SR 8EF1ED 8.01 W (180' H15) DON CVITY O O REFER 10 9 4111 5/11512 108 ATER BOOST HEATEWN R I PIPIN DETAIT BOOSTER HEATER. L. O Y BURRY O7/44512 UTLET & POR Y SLUSOAARRT Y RE TURN RUN BELOW COUNTER, THEN UP IN WALL. REFER TD DETAI • 46" COD WATER STUB -OUT AT +12" A.F.F. FOR SOMAT MAKE -UP WATER. • WING TO BE RIRJ AT 449111408 13' -0" A.F.F. OVER ICE MAKER AREA. Il ROUTE Y GAS (GTH ) DOWN P N 11.DS AND CONNECT TO VALVE ASSEMBLY IN VERTICAL Q1 60 ENDS 0 U.D.S. O ROUT0e. 7 Y /84512 5110390 OUTLET & SLURRY RETURN PIPING ABOVE THE CEILING. SEE D15 Y GAAS 9_ 3 (G) LW l 18880 ROOF. SEE DRAWING 44300 FOR CONTINUATION & DET/iL580. 14 4' VENT 3/84 (V) 510. 1OK)1 ROOF. SEE DRAVAN0 44300 FOR CONTINUATION & OETAB_ HR KEY NOTES FOR SHEET 1/M140 ,C> 111 VENT (V) UP. SEE 2/84140 FOR CONTINUAITON • 2" VENT (V) UP. SEE 2/84140 FOR CONTINUAITON. • 2" P -TRAP UNE, IN MUSHROOM BASE, AT 12" A.F.F. CAPPED FOR FUTURE USE. 4 2 " OVERFLOW & FEATURE DRAI5 STUD 1580004 1 REFER TO OLYMPIC 80015 VENDOR SHOP DRAWING W400 & DETAIL 2/044 FOR MORE INFORMATION. 5 6 "0 110 WITH LONG RA01U5 118005 108 SODA UNES BELOW 11000 SLAB. STUB UP IN MUSHROOM STEM CAVITY AND 805E OF COUNTER. KEY NOTES FOR SHEET 2/M140 KEY NOTES FOR SHEET M100 • 11" VENT (V) UP. SEE M110 FOR CONTINUATION. • 2" VENT (V) UP. SEE M110 FOR CONTINUATION. • 3' VENT (V) UP. SEE M110 FOR CONTINUATOR. y PROVIDE TAIL PIECE FROM TRAP FOR UNDER LOONIER 015181*8(R. 019JWA5HER 8Y OWNER AND 1958/0110 8Y 8ECHANICAL CONTRACTOR. • 44' COLD WATER (CW) FROM (P17). UNDERFLOOR TO RUSHING FLOOR SINK (152). • WASTE PIPING ABOVE GROUND IN PLUMBING CHASE. • 4" WASTE DOWN THROUGH FLOOR. B EXISTING STM AIN (). ELD ERIFY NVERT E LEVATION AND REPORT ANY 8 PROBLEMS T 111E DR ENGIN 81FI1081 V 58/90 WORK. • 1415140 SANITARY 50818 ( S5 ) . FIELD VERIFY INVERT ELEVATION AND REPORT ANY PROBLEM5 TO 111E ENGINEER BEFORE STARTING WORK. PROVIDE 7,000 GAL. GREASE INTERCEPTOR WITH A 6" INLET AND A 6' OUTLET ■• AT A APPROXIMATE INVERT ELEVATION OF 25' -0'. FIELD VERIFY AND REPORT ANY DESCREPANCIES TO 711E ENGINEER BEFORE STARTING WORK. 11 2" OVERFLOW STUB THROUGH ROOK. REFER TO OLYMPIC POOLS VENDOR SHOP DRAWING 0500, DETAIL 8/W500 FOR MORE INFORMATION. O 2' TURE RAIN STU THROGH BOOR. FER O OMPIC POOLS VENDOR SHOP FEA DRAWIN 0500, DET AIL 3 FOR MOR IN /.� 2' 0VERFL0W & FEATURE DRAIN STUB 1HRWGH R00R. REFER TO OLYMPI0 POOLS VENDOR SHOP DRAWING 8300 & DETAIL 11/6001 FOR MORE INFOPoAATON. 14 CONNEC0 EXISTING 4' SANITARY SEWER ( 5S ) . FIELD VERIFY INV REPORT AN Y PROBLEMS TO THE ENGINEER BEFORE STARTING WORK. ERT ELEVATION AND Q CONNECT TO EXIS1NG 6" SANITARY SEWER (5S). FIELD VERIFY INVERT ELEVATION AND REPORT ANY PROBLEMS TO 111E ENGINEER BEFORE STARTING WORK. • 4" VENT (V) FOR GREASE INTERCEPTOR. 0. 4" WASTE DOWN THROUGH FLOOR AND 111" VENT UP. ® 11" GAS (0) UP THROUGH ROOF. SEE DRAWING M3 DETAIL 3/M510. ® MOUNT TRAP PRIMER (P16) IN CEILING SPACE. ROUTE PROTECTED COLD WATER (PCW PRIMER 0915 D0WN IN WALL A" UNDERFLOOR TO 11008 DRAIN (FD2) 080984 ON 11100. © 2' SLURRY OUTL & 2" SWRRY RETURN DOWN EXPOSED ALONG WALL. REFER TO SHEET 7/81512 ET FOR 2" DETAIL ® /Y 120' DETAI SOFTENED L HOT WATER (120' SHW). REFER TO SHEET 7/M512 FOR SO MAT EXPOSED VENT PIPING IN 50MAT ROOM. • N COLD WATER (CW) STUB OUT +48" A.F.F. CAPPED FOR FUTURE USE. • Ilk" VENT (V) DOWN. SEE 1/M140 FOR CONTNUAITON. • 2' VENT (V) DOWN. SEE 1/14140 FOR 0090900)109. O 115" LL 0444 COLD 10 WATER & DOWN (CW) TO B 111' ELOW 120' COUNTER. SOFTENED HOT WATER (120' SHW) PIPE INTO WA /� ROUTE COLD WATER (CW) & 120' 501TENE0 HOT WATER (120' SHW) PIPING IN WALL `4 CAVITY BELOW COUNTERTOP OF BAR. STUB OUT OF WALL AND CONNECT TO EQUIPMENT AS NOTED. COY OF 01.000 /1 00000YO0 OCT 161635 80 Dale 0escripllan Comm. No. Cwurgham Group Architecture Inferior Design Planning Construction Services 201 Main St. S.E. Suite 325 Minneapdis, MN 55414 Telephone: 612 -379 -3400 Facsimile. 612- 379 -4400 Internet: mar uningham nom 7/2/08 CAP115 RAINFOREST CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS Sheet Tee PLUMBING KEY NOTES Sheet Surber 51010010 CFlY OP 10104(10 SE) 1 1 1593 PERMIT CENTER M160 x fl() t- '74 O 1 HVAC PLAN va = T -m O NORTH KEY NOTES O BALANCE TO 2500 CFM PRIOR TO INSTALLATION OF GREENERY CEIUNG. O BALANCE TO 1000 CFM PRIOR TO 150141 00ON OF GREENERY CEILING. C > 30/18 RETURN AIR DUCT OPENING ABOVE GREENERY CEIUNG, 84000 THERMOSTAT SENSOR IN FRONT OF RETURN AIR DUCT OPENING, COVER OPENING WITH 1/2" X 1/2" SCREEN MESH. BALANCE TO 3100 CFM PRIOR TO INSTALLATION OF GREENERY CEIUNG. 0 1 20/18 RETURN AIR DUCT OPENING ABOVE GREENERY CEIUNG, MOUNT THERMOSTAT SENSOR IN FRONT OF RETURN AIR DUCT OPENING, COVER OPENING WITH 1/2" X 1/2" SCREEN MESH. BALANCE TO 2500 CFM PRIOR TO INSTALLATION OF GREENERY CEIUNG. 01 5 COVER 12/12 TRANSFER AIR DUCT OPENING WITH i/2" X 1/2" SCREEN MESH. 01 6 COMBINATION SMOKE /FIRE DAMPER. <> 20/50 RETURN AIR DUCT OPENING IN TOP OF DUCT LOCATED ABOVE GREENERY CEIUNG. COVER OPENING 8100 1/2" X 1/2" SCREEN MESH. O COVER 12/8 TRANSFER AIR DUCT OPENING WITH 1/2" X 1/2" SCREEN MESH. O g 16 /I6 00MBU50014 AIR DUCT OPENING NEAR CEIUNG WITH TYPE 0 -16 /16 GRILLE. <> 16/32 COMBUSTION AIR DUCT UP TO COMBUSTION AIR INTAKE ON ROOF. SEE DETAIL 10/8511 FOR INSTALLATION 000061EMENTS. 11 DETIL 3/651 FOR WATER ATE VENT PNG AND INDU CED A DRAFT FA N INSTALLATION HE 800 015060619. IPI *INSTALL DUCTWORK UP IN JOIST SPACE. 0 ,24/24/24 HIGH PLENUM WIN 14 "0 DUCT COLLAR. CONNECT TO 24/24 PERFORATED SUPPLY AIR GRILLE. 14 FILTER RACK 1 811 2" THICK 48/24 305 PLEATED FILTERS. 15 <> COORDINATE LOCATIONS OF TYPE C SUPPLY AIR DIFFUSERS WITH THE REFLECTED CEILING PLAN SHEET E104. SUPPLY AIR DIFFUSERS ARE TO BE LOCATED IN MUSHROOM GILLS. 16 REFER TO DETAIL 8/M510 FOR SUPPLY FAN DETAIL. 17 INSTALL ELECTRIC HEATING COIL IN DUCTWORK PER MANUFACTURERS RECOMMENDATIONS. DETA ILS. C5, REFER TO DETAIL 5/8510 AND ARCHITECTURAL 19 20/24 EXHAUST DUCT CONNECTION TO HOOD. • FULL 512E SUPPLY AND RETURN AIR DUCTS UP TO RTU -1. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATOR OF DUCTWORK. 21 FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RN -2. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATORS PRIOR TO FABRICATION OF DUCTWORK. ® FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RTU -3. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATORS PRIOR TO FABRICATION OF DUCTWORK. ®FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RTU -5. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATION OF DUCTWORK. FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO R1U -6. VERIFY RN DUCT CONNECTOR SIZES AND LOCATORS PRIOR TO FABRICATION OF DUCTWORK. ®FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RN -7. VERIFY RN DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATION OF DUCTWORK. ®FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RN -8. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATOR OF DUCTWORK. ©FULL SIZE SUPPLY AIR DUCT UP TO 680 -1. VERIFY MAU DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATOR OF DUCTWORK. ®FULL SIZE EXHAUST DUCT UP TO EF -4. EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. ®FULL SIZE EXHAUST DUCT UP TO EF-5. EXHAUST DUCT TO BE SAME 512E AS EXHAUST FAN DAMPER ®FULL SIZE EXHAUST DUCT VP TO EF -6. EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. 31 FULL S12E EXHAUST DUCT UP TO EF -7. EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. *20/48/18 DEEP SUPPLY AIR PLENUM. *20/48/18 DEEP SUPPLY AIR PLENUM. 11 COVER 16/14 TRANSFER AIR DUCT OPENING WITH 1/2" X 1/2• SCREEN MESH. ® / COMBUSTION 4UCOWN TO 2" ABOVE FLOOR. COVER O ING VA111 1/2" X 16 1/2 " SCR 655 gENERAL NOTES 1. COORDINATE LOCATOR OF SUPPLY AIR DIFFUSERS IN DINING AND RETAIL AREAS WITH ARCHITECTURAL CEILING HEIGHTS. SUPPLY AIR DIFFUSERS SHALL BE LOCATED FLUSH WITH GREENERY PANEL CEIUNG WITH DUCTWORK CONCEALED ABOVE GREENERY CEILING. 2. COORDINATE LOCATIONS OF CEILING DIFFUSER, RETURN AND EXHAUST REGISTER /GRILLE LOCATIONS 481* UGHT FIXTURES. 3. FLEXIBLE DUCTWORK IS NOT ACCEPTABLE ABOVE GREENERY CEILING. 4. INSTALL ALL SIDEWALL GRILLES & REGISTERS FLUSH 41T1 FINISHED WALLS. 5. INSTALL ALL DUCTWORK ABOVE GREENERY CEILING TIGHT TO STRUCTURE. COORDINATE ALL DUCT HEIGHTS WITH LIGHTING FIXTURES. FIRE SPRINKLER PIPING, AND OTHER TRADES. CITY 0f Tt17ifIL -1 APi'fi0i� OCT 1 616 s r Date Carom. No. Sheet Tore HVAC Sheet Rubor Currgham Group Architecture Interior Design Planning Construction Services 201 Main SL S.E. Suite 325 Minneapolis. MN 55414 Telephone: 612-379-3400 612-379-4400 ..scut www.cuningham.com RAIN OREST CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS 6401101/) CR OF T U160ILA SEP 1 1 1590 PERMIT CENTER M200 7/2/98 CAP115 I !. 111E 6 7 (8 / 9 ( 10 11 1 2 1 \ V 11 20/24 6-100 8/8 D- 50 -8/8 F� u- lso-za /24 -3500 -24/ TYP 4 8m � 200 L _ f � I ,, o o •—� � • -TO R ev �� 1 . �.', 66 a F - B- . -10 �1 M+a" �� , ,__L.,---7)r . '�' I II B ". 8 6 / .,.. 4Y i � �: I© `` I Y II ° A 2a'° D-200-12/6 _ i t I2 � ' 7 ; I ' I � RE k � II . ►.� '1 �4 E 4/10 I D -50 e/8 ,m . :.I B -125 -8 E-12/8 © 0 © till xO al � �oa � 1E� 1 �_• 1111 B . E - , 2,6 {� 0 fNlal-■a r� ® --V+ ° m0 1 111 1i p i _ air S ` F 'f 11 l��►_ � PM , ,-- 14 �� ,, 5 fF7 ! 1 _ ��- Q 1 1 I �91f El B A e R• li ti� 0 � 1 4 � � 7- m • 1 �, irilitEl. NI 11111111111111111 _ % ® ® O 8 L . �EE;,:.lezAr ffi(ii(iffii_+ ■ ■ �• B -255 -8 2/24 � ;!171 I M -125 -8 ® % i r °0 i 25-8 !'I, D 200 -12/6 E- 525 -16/14 0 12 ® 1111111.122211=11112=1:111•11 e a •'u 11 9 1300 -20/16 \ W I nI oa ,- � 81==i0.1 TO E- 1300 ( _Z__ -20 =� = AVER . -� i "' . TYP 6 1 r 1 i 0 I 6 -20o --1 z/6 EE0 I t �� o-zol � � " A E- 200 -12/6 l e1 � Y E uu I Krzi REFER TO SHEET M 10 FOR WORK IN THIS REA ut 16 "0 TIP n TO R16-6 ) .,. IL ® OR ROOF _ o X II CI� ++ - © ! 48/20 00 — � re � H- 200 -8 -48 111 Tm a \2/20 o 4-MMIll ° IMO Z II fi U r, J i f IN . II � I n aTi m .,, "„ ..,,...,, T. 6 4 A / / // / \) yy � � tea' - ■ / // / // �F 7 CO El Y Ru REFER TO -HEFT 8210 / \ 0 \\\ / / / / / \ // U FOR CONT UATON 2 50/20, E Mil I MI ® 40/ 20 U / O'© // A- 585-12 .1,7,5855-12 YP 6 "4 11 80 IKr'I - / / e 1 . % � . 48/20 II 1 18/18 U U A 42/20 1 14 . 0 TYP A- 685 -14 U YY OM ILA Nal °� • / � 1� U�' 12 12/1 L -- J , 080-8 • D OBI- 1 00 -8 —.� V l BI 100-6 0 �• u>r I 12/12 MI JIB � � c- aDD -1z T ) � i _4 - -- . r...r X X x fl() t- '74 O 1 HVAC PLAN va = T -m O NORTH KEY NOTES O BALANCE TO 2500 CFM PRIOR TO INSTALLATION OF GREENERY CEIUNG. O BALANCE TO 1000 CFM PRIOR TO 150141 00ON OF GREENERY CEILING. C > 30/18 RETURN AIR DUCT OPENING ABOVE GREENERY CEIUNG, 84000 THERMOSTAT SENSOR IN FRONT OF RETURN AIR DUCT OPENING, COVER OPENING WITH 1/2" X 1/2" SCREEN MESH. BALANCE TO 3100 CFM PRIOR TO INSTALLATION OF GREENERY CEIUNG. 0 1 20/18 RETURN AIR DUCT OPENING ABOVE GREENERY CEIUNG, MOUNT THERMOSTAT SENSOR IN FRONT OF RETURN AIR DUCT OPENING, COVER OPENING WITH 1/2" X 1/2" SCREEN MESH. BALANCE TO 2500 CFM PRIOR TO INSTALLATION OF GREENERY CEIUNG. 01 5 COVER 12/12 TRANSFER AIR DUCT OPENING WITH i/2" X 1/2" SCREEN MESH. 01 6 COMBINATION SMOKE /FIRE DAMPER. <> 20/50 RETURN AIR DUCT OPENING IN TOP OF DUCT LOCATED ABOVE GREENERY CEIUNG. COVER OPENING 8100 1/2" X 1/2" SCREEN MESH. O COVER 12/8 TRANSFER AIR DUCT OPENING WITH 1/2" X 1/2" SCREEN MESH. O g 16 /I6 00MBU50014 AIR DUCT OPENING NEAR CEIUNG WITH TYPE 0 -16 /16 GRILLE. <> 16/32 COMBUSTION AIR DUCT UP TO COMBUSTION AIR INTAKE ON ROOF. SEE DETAIL 10/8511 FOR INSTALLATION 000061EMENTS. 11 DETIL 3/651 FOR WATER ATE VENT PNG AND INDU CED A DRAFT FA N INSTALLATION HE 800 015060619. IPI *INSTALL DUCTWORK UP IN JOIST SPACE. 0 ,24/24/24 HIGH PLENUM WIN 14 "0 DUCT COLLAR. CONNECT TO 24/24 PERFORATED SUPPLY AIR GRILLE. 14 FILTER RACK 1 811 2" THICK 48/24 305 PLEATED FILTERS. 15 <> COORDINATE LOCATIONS OF TYPE C SUPPLY AIR DIFFUSERS WITH THE REFLECTED CEILING PLAN SHEET E104. SUPPLY AIR DIFFUSERS ARE TO BE LOCATED IN MUSHROOM GILLS. 16 REFER TO DETAIL 8/M510 FOR SUPPLY FAN DETAIL. 17 INSTALL ELECTRIC HEATING COIL IN DUCTWORK PER MANUFACTURERS RECOMMENDATIONS. DETA ILS. C5, REFER TO DETAIL 5/8510 AND ARCHITECTURAL 19 20/24 EXHAUST DUCT CONNECTION TO HOOD. • FULL 512E SUPPLY AND RETURN AIR DUCTS UP TO RTU -1. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATOR OF DUCTWORK. 21 FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RN -2. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATORS PRIOR TO FABRICATION OF DUCTWORK. ® FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RTU -3. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATORS PRIOR TO FABRICATION OF DUCTWORK. ®FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RTU -5. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATION OF DUCTWORK. FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO R1U -6. VERIFY RN DUCT CONNECTOR SIZES AND LOCATORS PRIOR TO FABRICATION OF DUCTWORK. ®FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RN -7. VERIFY RN DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATION OF DUCTWORK. ®FULL SIZE SUPPLY AND RETURN AIR DUCTS UP TO RN -8. VERIFY RTU DUCT CONNECTOR SIZES AND LOCATIONS PRIOR TO FABRICATOR OF DUCTWORK. ©FULL SIZE SUPPLY AIR DUCT UP TO 680 -1. VERIFY MAU DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATOR OF DUCTWORK. ®FULL SIZE EXHAUST DUCT UP TO EF -4. EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. ®FULL SIZE EXHAUST DUCT UP TO EF-5. EXHAUST DUCT TO BE SAME 512E AS EXHAUST FAN DAMPER ®FULL SIZE EXHAUST DUCT VP TO EF -6. EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. 31 FULL S12E EXHAUST DUCT UP TO EF -7. EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. *20/48/18 DEEP SUPPLY AIR PLENUM. *20/48/18 DEEP SUPPLY AIR PLENUM. 11 COVER 16/14 TRANSFER AIR DUCT OPENING WITH 1/2" X 1/2• SCREEN MESH. ® / COMBUSTION 4UCOWN TO 2" ABOVE FLOOR. COVER O ING VA111 1/2" X 16 1/2 " SCR 655 gENERAL NOTES 1. COORDINATE LOCATOR OF SUPPLY AIR DIFFUSERS IN DINING AND RETAIL AREAS WITH ARCHITECTURAL CEILING HEIGHTS. SUPPLY AIR DIFFUSERS SHALL BE LOCATED FLUSH WITH GREENERY PANEL CEIUNG WITH DUCTWORK CONCEALED ABOVE GREENERY CEILING. 2. COORDINATE LOCATIONS OF CEILING DIFFUSER, RETURN AND EXHAUST REGISTER /GRILLE LOCATIONS 481* UGHT FIXTURES. 3. FLEXIBLE DUCTWORK IS NOT ACCEPTABLE ABOVE GREENERY CEILING. 4. INSTALL ALL SIDEWALL GRILLES & REGISTERS FLUSH 41T1 FINISHED WALLS. 5. INSTALL ALL DUCTWORK ABOVE GREENERY CEILING TIGHT TO STRUCTURE. COORDINATE ALL DUCT HEIGHTS WITH LIGHTING FIXTURES. FIRE SPRINKLER PIPING, AND OTHER TRADES. CITY 0f Tt17ifIL -1 APi'fi0i� OCT 1 616 s r Date Carom. No. Sheet Tore HVAC Sheet Rubor Currgham Group Architecture Interior Design Planning Construction Services 201 Main SL S.E. Suite 325 Minneapolis. MN 55414 Telephone: 612-379-3400 612-379-4400 ..scut www.cuningham.com RAIN OREST CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS 6401101/) CR OF T U160ILA SEP 1 1 1590 PERMIT CENTER M200 7/2/98 CAP115 SEE 2/M210 FOR CONTINUATION fl KITCHEN HVAC PLAN 1 1 / va• = an• NORTH KEY NOTES , F6 /20pGREASE OF DUCT UP TO EXHAUST 68-4 ON ROOF, REFER TO DRAWING 8300. OCATIO 2 26/28 GREASE DUCT UP TO EF -2 ON ROOF. REFER TO DRAWING M300 FOR LOCATION OF EXHAUST FAN. O BALANCE TO 6500 CFM. 19/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS • PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 2125 CFM. O 28/12 MAKE -UP AIR DUCT CONNECTION TO HOOD, VERIFY COLLAR LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1700 CFM. 29/10 GREASE DUCT CONNECTION TO H000. PROVIDE ACCESS 0 PANEL AT CONNECTION TO H000, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 3300 CFM. 25/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS O J PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 2800 CFM. 20/12 MAKE -UP AIR DUCT CONNECTION TO HOOD, VERIFY COLLAR 8 LOCATOR PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1320 CFM. O 30/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS 9 PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 3400 CFM. 10 16/4 DUCT CONNECTOR TO DISHMACHINE, VERIFY COLLAR 512E PRIOR TO FABRICATION BALANCE TO 200 CFM. 11 16/4 DUCT CONNECTION TO DISHMACHINE VERIFY COLLAR SIZE PRIOR TO FABRICATION BALANCE TO 400 CFM. 1 FULL SIZE SUPPLY AIR DUCT UP TO TF -1. VERIFY TRANSFER FAN DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK FULL SIZE RETURN AIR DUCT UP TO TF -1. VERIFY TRANSFER FAN 13 DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK. 14 EXACT ONR 2 7 08 - . 1, EF -1 AND EF -2. COORDINATE 15 ACCESS PANEL tfi TO ACC C SPACE TO PERMIT EASY ACCESS O. SLOPE GREASE DUCT 1 /4 "/FT DOWN TOWARD EXHAUST HOOD. 20/10 MAKE -UP AIR DUCT CONNECTION TO HOOD. VERIFY COLLAR LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1120 CFM. 0 LOCATION PRIOR TO R FABRICATOR TO E OF DUCTWORK. TO 1360 CFM. 00 TO RTU -4 ON ROOF. 21 BALANCE TO 9725 CFM. ® FULL SIZE SUPPLY AIR DUCT UP TO RTU -4. VERIFY RTU DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK. FULL SIZE RETURN AIR DUCT UP TO R10 -4. VERIFY RTU DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK. ® GREASE DUCT TR0004 WITH 3/4° DRAIN VALVE, HOSE CONNECTION AND WATER /GREASE TIGHT CAP. REFER TO DETAIL 2/M512 FOR INSTALLATION REQUIREMENTS. • 16/16 EXHAUST AIR DUCT UP TO EF -3 ON ROOF. • ROOF OPENING AND CURB BY MECHANICAL CONTRACTOR. 00 REFRIGERANT PIPING 15 FURNISHED AND INSTALLED BY DEI. PIPE ROUTING SHOWN IS FOR INFORMATION AND COORDINATION ONLY. EXACT LOCATION AND ROUTING SHALL BE COORDINATED BY PCL AND DEI. PIPING SHALL BE INSTALLED PRIOR TO WALL CLOSURE. • DISH`NASH EXHAUST WRK, FER TO SPECIRCATIONS. EXPOSER DUCTWORK SHA O BE STAINLESS STEEL, CONCEALED DUCTWORK SHALL BE ALUMINUM OR STAINLESS STEEL WITH ALL JOINTS SEALED WATER TIGHT. PITCH DUCTWORK A MINIMUM OF 1/4° PER FOOT TOWARD DISHWASHER. REFRIGERANT PIPING TO EACH COOLER /FREEZER BY DEI. P TO REFRGERATION UNIT BY D 586 08AWING FOR I009590ATION. ON ROOF 3O COMBINATION SMOKE /FIRE DAMPER. • FULL SIZE EXHAUST AIR DUCT UP TO EF -8, EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. ® REFER TO DRAWING 8200 FOR CONTINUATION. GENERAL NOTES 1. COORDINATE LOCATIONS OF CEILING DIFFUSER. RETURN AND EXHAUST GRILLE LOCATIONS WITH LIGHT FIXTURES. 2. FLEXIBLE DUCTWORK IS NOT ACCEPTABLE. 3. COORDINATE ALL DUCT HEIGHTS WITH LIGHT FIXTURES, FIRE SPRINKLER PIPING AND OTHER TRADES. SEE 1/M210 FOR CONTINUATION 0- 125 -10/6 MAINTENANCE ROOM KITCHEN HVAC PLAN No. Date Description Date: Comm. No. Sheet lib KITCHEN HVAC PLAN CITY OF TUMID; 1 '- t i 0 Sheet Nutter OCT 16 IST3 Cuningham Group Architecture Interior Design Planning Construction Ser4414 201 Main St. 5.E 5,10 325 Mnneapol s, MN 55414 Telephone- 612-379-3400 510 -37 612 379 4400 www cu w n ngham.com 66101/80 CTYOP3UKWILA SEP 1 1 1696 PERMIT CENTER M210 7/2/98 CAP115 Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS ■ ••' •■ • 'fir .m0m _ . • • 1 • — • ■ r i w E' „ 1 1 I • • � Iii MEI ■ ■ ■ ft lPl 1 '1 6.I. ... ._ . 11 15 ° 0 bZ /bZ : ■ I ra 4' - J•I / 26/28 5.0 . OZ /9 y4..: [ :#«: 1 ' lin I. Q In , (^ C KITCE r� �I MENHIR a1 l � C � `� V I 4 © ;e � � I 15 II I �I�Gi v I 15 ° 0 ,r; l 94 /Ol MU I ,Ixil , I g _ I X I I , & N 1 � � "" E �� H= � , 1 11 n 1111 ■ - - Folk 5 'F7 TTYYP912 �.. �I == E 0 11 Ilj � e r 1■1 � IB�1 �t� �4 �r;S,�y nn ` ∎'I ��� IRS It ■ a i� PPM 0 v Ica 6yI I e4 l l �ll l X � IR gbh/ 1 ti1 Mil bZ /4 J- 300 ■,l14 f�1� CI [ ! Il r l ., � II � ®� ' I 1 -1� • ® -10 ∎i 00 SER VICE I I'�i. 1 1 50/20 - -- CHEF'S 1 v� FA I 1 I ` -1_ � _ l F 1 ��ia Y vii [y • 81 -75 -6 6' fill j � f NA = - F- 900 -12/24 ill i ., \ 01 1 111101U r 11� 1.1°1 I —� �\ 15'0 bZ /Bb 15'0 Ir . I n 0 Q' . liagill 1 I\i 1 111 ( 4 1 � b 9l � 1 I 148/24 , I ►,,4 Kt. 9Z /ZL 1 15 " F -/ TYP 2448 3 �2 r_16101 u 15 °0 /' L i -. � g2 FR 48/30 I III ( CORRIDOR BOA SEE 2/M210 FOR CONTINUATION fl KITCHEN HVAC PLAN 1 1 / va• = an• NORTH KEY NOTES , F6 /20pGREASE OF DUCT UP TO EXHAUST 68-4 ON ROOF, REFER TO DRAWING 8300. OCATIO 2 26/28 GREASE DUCT UP TO EF -2 ON ROOF. REFER TO DRAWING M300 FOR LOCATION OF EXHAUST FAN. O BALANCE TO 6500 CFM. 19/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS • PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 2125 CFM. O 28/12 MAKE -UP AIR DUCT CONNECTION TO HOOD, VERIFY COLLAR LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1700 CFM. 29/10 GREASE DUCT CONNECTION TO H000. PROVIDE ACCESS 0 PANEL AT CONNECTION TO H000, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 3300 CFM. 25/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS O J PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 2800 CFM. 20/12 MAKE -UP AIR DUCT CONNECTION TO HOOD, VERIFY COLLAR 8 LOCATOR PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1320 CFM. O 30/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS 9 PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 3400 CFM. 10 16/4 DUCT CONNECTOR TO DISHMACHINE, VERIFY COLLAR 512E PRIOR TO FABRICATION BALANCE TO 200 CFM. 11 16/4 DUCT CONNECTION TO DISHMACHINE VERIFY COLLAR SIZE PRIOR TO FABRICATION BALANCE TO 400 CFM. 1 FULL SIZE SUPPLY AIR DUCT UP TO TF -1. VERIFY TRANSFER FAN DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK FULL SIZE RETURN AIR DUCT UP TO TF -1. VERIFY TRANSFER FAN 13 DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK. 14 EXACT ONR 2 7 08 - . 1, EF -1 AND EF -2. COORDINATE 15 ACCESS PANEL tfi TO ACC C SPACE TO PERMIT EASY ACCESS O. SLOPE GREASE DUCT 1 /4 "/FT DOWN TOWARD EXHAUST HOOD. 20/10 MAKE -UP AIR DUCT CONNECTION TO HOOD. VERIFY COLLAR LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1120 CFM. 0 LOCATION PRIOR TO R FABRICATOR TO E OF DUCTWORK. TO 1360 CFM. 00 TO RTU -4 ON ROOF. 21 BALANCE TO 9725 CFM. ® FULL SIZE SUPPLY AIR DUCT UP TO RTU -4. VERIFY RTU DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK. FULL SIZE RETURN AIR DUCT UP TO R10 -4. VERIFY RTU DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK. ® GREASE DUCT TR0004 WITH 3/4° DRAIN VALVE, HOSE CONNECTION AND WATER /GREASE TIGHT CAP. REFER TO DETAIL 2/M512 FOR INSTALLATION REQUIREMENTS. • 16/16 EXHAUST AIR DUCT UP TO EF -3 ON ROOF. • ROOF OPENING AND CURB BY MECHANICAL CONTRACTOR. 00 REFRIGERANT PIPING 15 FURNISHED AND INSTALLED BY DEI. PIPE ROUTING SHOWN IS FOR INFORMATION AND COORDINATION ONLY. EXACT LOCATION AND ROUTING SHALL BE COORDINATED BY PCL AND DEI. PIPING SHALL BE INSTALLED PRIOR TO WALL CLOSURE. • DISH`NASH EXHAUST WRK, FER TO SPECIRCATIONS. EXPOSER DUCTWORK SHA O BE STAINLESS STEEL, CONCEALED DUCTWORK SHALL BE ALUMINUM OR STAINLESS STEEL WITH ALL JOINTS SEALED WATER TIGHT. PITCH DUCTWORK A MINIMUM OF 1/4° PER FOOT TOWARD DISHWASHER. REFRIGERANT PIPING TO EACH COOLER /FREEZER BY DEI. P TO REFRGERATION UNIT BY D 586 08AWING FOR I009590ATION. ON ROOF 3O COMBINATION SMOKE /FIRE DAMPER. • FULL SIZE EXHAUST AIR DUCT UP TO EF -8, EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. ® REFER TO DRAWING 8200 FOR CONTINUATION. GENERAL NOTES 1. COORDINATE LOCATIONS OF CEILING DIFFUSER. RETURN AND EXHAUST GRILLE LOCATIONS WITH LIGHT FIXTURES. 2. FLEXIBLE DUCTWORK IS NOT ACCEPTABLE. 3. COORDINATE ALL DUCT HEIGHTS WITH LIGHT FIXTURES, FIRE SPRINKLER PIPING AND OTHER TRADES. SEE 1/M210 FOR CONTINUATION 0- 125 -10/6 MAINTENANCE ROOM KITCHEN HVAC PLAN No. Date Description Date: Comm. No. Sheet lib KITCHEN HVAC PLAN CITY OF TUMID; 1 '- t i 0 Sheet Nutter OCT 16 IST3 Cuningham Group Architecture Interior Design Planning Construction Ser4414 201 Main St. 5.E 5,10 325 Mnneapol s, MN 55414 Telephone- 612-379-3400 510 -37 612 379 4400 www cu w n ngham.com 66101/80 CTYOP3UKWILA SEP 1 1 1696 PERMIT CENTER M210 7/2/98 CAP115 Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS S ( KEY NOTES O =au - 1, 196' X 61" X 56' HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR. 2100 L85. REFER TO DETAIL 1/6511 FOR INSTALLATION REQUIREMENTS. O CU -1, 51" X 36" X 53" HIGH INCLUDING RAIL SUPPORTS, 600 LBS. REFER TO DETAIL 6/6511 FOR INSTALLATION REQUIREMENTS. 3 O RTU-1, 107 X 71° X 64" HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR, 1850 LBS. REFER TO DETAIL 1 /M511 FOR INSTALLATION REQUIREMENTS. RTU -2, 107 X 71" X 64" HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR. 1850 LBS. REFER TO DETAIL 1/6511 FOR INSTALLATION REQUIREMENTS. RTU -3, 107 X 71" X 64" HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR, 1850 LBS. REFER TO DETAIL 1/0511 FOR INSTALLATION REQUIREMENTS. B O RTU -4, 216' X 91" X 85' HIGH ON SUPPORT RAILS. BY GENERAL CONTRACTOR, 4500L05. REFER TO DETAIL 1/651, FOR INSTALLATION REQUIREMENTS. RTU -5. 96' X 47 X48' HIGH WITH CURB, 950 LB5. REFER TO DETAIL 4/6511 FOR INSTALATION REQUIREMENTS. 8O RTU -6, 103" X0 X 49" HIH WTH CURB, 90 LB5. REFER TO 061011. 5 4 /6511 FOR G INSTALAOON R 9O RTU -7, 96° X 47" X 48" HIGH WITH CURB, 900 LBS. REFER TO DETAIL 4/651, FOR INSTALLATION REQUIREMENTS. 10 RTU -8, 103" X 50" 0 49' HIGH WITH RB, 0 LB5. REFER TO 061011 4/6511 FOR INSTALLATI REQ 1f TF -1, 143" X 61" X 58" HIGH ON SUPPORT RA/LS, BY GENERAL CONTRACTOR, 1625 LBS. REFER TO 0ETNL 1/6511 FOR INSTALLATION REQUIREMENTS. Q EF -1, 38' X 40" X 54° HIGH INCLUDING RAIL SUPPORTS, 540 LBS. REFER TO DETAIL 3/6511 FOR INSTALLATION REQUIREMENTS. 13 EF -2 49" X 51° X 72" HIGH INCLUDING RAIL SUPPORTS, 960 LBS. REFER TO DETAIL 3/6511 FOR INSTALLATION REQUIREMENTS. 14 KITCHEN REFRIGERATION UNIT, 72" X 60 X 60" HIGH WITHOUT CURB. 2400 LBS. FURNISHED AND INSTALLED BY OEI (UNIT SUPPUER). MECHANICAL CONTRACTOR SHALL PROVIDE TWO (2) 14" HIGH MINIMUM ROOF SUPPORT RAILS WITH FLASHING. SEE ARCHITECTURAL DRAWINGS FOR DETAIL. COUNTER FLASHING BY MECHANICAL CONTRACTOR. HELD VERIFY EXACT CURB SIZE PRIOR TO INSTALLATION. ALL REFRIGERANT PIPING 15 FURNISHED AND INSTALLED BY DLL. • ICE MACHINE AIR COOLED CONDENSER U911, EACH APPROXIMATELY 30" X 30' X 36' HIGH WITHOUT CURB, 110 LBS. FURNISHED BY ICEMAKERS AND INSTALLED BY DEL. MECHANICAL CONTRACTOR SHALL PROVIDE FOUR (4) 14" HIGH MINIMUM INSULATED ROOF CURBS AND TWO (2) ROOF OPENINGS. REFRIGERANT PIPING BY DEL. ROOF CURBS SHALL BE A FULL PERIMETER TYPE CURB WITH AN INSULATED SHEETMEFAL CAP AND FLASHING, COUNTER - FLASHING BY THE ROOFING CONTRACTOR. RELD VERIFY EXACT REQUIREMENTS PRIOR TO INSTALLATION. • 2 TON AIR COOLED CONDENSING UNIT, APPROXIMATELY 34" X 24 X 18" HIGH WITHOUT CURB, 150 LBS. UNIT IS FURNISHED BY ICM. MECHANICAL CONTRACTOR SHALL PROVIDE A 14" HIGH MINIMUM INSULATED ROOF CURB, ROOF OPENING AND REFRIGERANT PIPING. INSTALL PIPING FROM OUTDOOR UNIT TO INDOOR HEAT EXCHANGER MOUNTED ON !CIA SKID. ROOF CURB SHALL BE A FULL PERIMETER TYPE CURB WITH AN INSULATED SHEETMETAL CAP AND FLASHING WITH COUNTERFLASHING BY THE ROOFING CONTRACTOR. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO INSTALLATION. 0 GREASE TIGHT ACCESS PANEL 0 EX150110 CONDENSING UNIT AND PIP1140 TO REMAIN. 19 16/32 COMBUSTION AIR INTAKE. REFER TO DETAIL 10/14511 FOR INSTALLATION REQUIREMENTS. . 170 WATER HEATER VENT UP THROUGH ROOF. REFER TO DETAIL 12/9511 FOR INSTALLATION REQUIREMENTS. 0 14 "9 WATER HEATER VENT UP THROUGH ROOF. REFER TO DETAIL 12/9511 FOR INSTALLATION REQUIREMENTS. INSTALL REFRIGERANT PIPING PER MANUFACTURERS RECOMMENDATIONS. REFER TO DETAIL 7/0511 FOR INSTALLATION REQUIREMENTS. ® REFRIGERANT PIPING DOWN THROUGH ROOF. REFER TO DETAIL 8/9511 FOR INSTALLATION REQUIREMENTS. O . REFER TO DETAIL 4/6511 FOR INSTALLATION REQUIREMENTS. o) REFER TO DETAIL 5/M511 FOR INSTALLATION REQUIREMENTS. EXISTING ROOFTOP EQUIPMENT TO BE REMOVED BY LANDLORD. EXISTING MALL EQUIPMENT TO BE REMAIN. EXISTING ROOF DRAIN TO REMAIN. VERIFY EXACT LOCATION OF GAS METER WITH GAS COMPANY & THE MALL REPRESENTITNE. GAS SERVICE AND METER BY GAS COMPANY. 3,900 CFH 2 P5) DISCHARGE PRESSURE. PROVIDE SHUT -OFF VALVE ON METER DISCHARGE. 7' ( LINOWN THROUGH ROOF 006 GAS CONTI G UATION E D 0010 DETAIL 3/0510. . -SEE DRAWING M130 101" GA 5 (G) LANE DOWN THROUGH OF. SEE DRAWING M110 31 FOR C0 AND DETAIL 3/951 REFER ATOR 1O . DETAIL 4/9510 FOR PIPING AT GAS PRESSURE REGUL 3 ET AIL " VENT 3/9510. THROUGH ROOF. SEE DRAWING M110 FOR CONTINUATION & D 4 4" ETAIL VENT 3/051 THROUGH 0. ROOF. SEE DRAWING M130 FOR CONTINUATION & D NOTE: ALL UNIDENTIFIED ROOFTOP EQUIPMENT INDICATED WITH DASHED LINES IS EXISTING, AND LOCATIONS ARE APPROXIMATE. 1 NOTE: ALL ROOFING WORK ASSOCIATED WITH THE INSTALLATION OF NEW MECHANICAL EQUIPMENT TO INCLUDE CURBS, ROOF OPENINGS FOR DUCT PENETRATIONS, PIPING ETC... SHALL BE PERFORMED BY THE LANDLORD'S APPROVED ROOFING CONTRACTOR AT THE TENANT'S EXPENSE. CirY 0 1 2' ii ) 9YNNYrrer Date Na. Dale Description Cuningham Group Architecture Interior Design Planning Construction Services 201 Main SL SE. Suite 325 Minneapolis, MN 55414 Telephone: 612 -379 -3400 Facsimile: 612-379-4400 Internet: vmw.cuninghom.corn RAINFOREST CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS ROOF HVAC /PLUMBING PLAN REC51VE0 5000FIUISA0IA SEP 1 1 ((93 PERMITCENTER M300 7/2/88 CAP116 1111B \Dllf I ) I — Y ( 6 1 8Y) I 0 1 r® 1 1 10 1 11 1, 1� I -, — VHi - 1 fm . * III V © 1 _ - - Y11 ® • o. e OLI L m r © �L i ' � / / O I ° of.' 4 r / /zli;1 \+, fir; � L , _J a L_ 1Y " © — � u© ink . A ®IN ®// ®ii® fYfl VA — O 1 ' ,..:4 \ \ \,.. Y, 117 i 11 1.1111 \ 1 1• I I/ 11 N ®I ( II Li 111 uD 1 Tin 11/ 11 LL IN II N. itea k r T7 1 -1 1 Mai. r 1 1-F-, O g 44 E \ I / n \/ / L � i� ` 114" 1 G 4 �4]La 20 ' .® �F • Y Y \ \ \ \\ �y L 1 O I 4411 2 e4" fig V I 1 ROOF HVAC o LAN 0 NOTE: MECHANICAL CONTRACTO°'SHALL INSTALL ROOFTOP UNITS RTU -1. THRU RT -4, MAU -1 AND TF -1 ON STRUCURBS FO CTURA R L UNITS RAIL SUPPORT RAIL SUPPORTS SHALL TE BY GENERAL CONTRACTOR. REFER TO STRUCTURAL IRAWINGS. ROOF SUPPORT RTU 5 THRU S. CONSTRU -8 CTION SHAL OF BE FURNISHED AND INSTAL ED BY MECHANICAL CONTRACT e R. 1 ` — � � ■I' I 1/Er =ra NORTH S ( KEY NOTES O =au - 1, 196' X 61" X 56' HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR. 2100 L85. REFER TO DETAIL 1/6511 FOR INSTALLATION REQUIREMENTS. O CU -1, 51" X 36" X 53" HIGH INCLUDING RAIL SUPPORTS, 600 LBS. REFER TO DETAIL 6/6511 FOR INSTALLATION REQUIREMENTS. 3 O RTU-1, 107 X 71° X 64" HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR, 1850 LBS. REFER TO DETAIL 1 /M511 FOR INSTALLATION REQUIREMENTS. RTU -2, 107 X 71" X 64" HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR. 1850 LBS. REFER TO DETAIL 1/6511 FOR INSTALLATION REQUIREMENTS. RTU -3, 107 X 71" X 64" HIGH ON ROOF SUPPORT RAILS, BY GENERAL CONTRACTOR, 1850 LBS. REFER TO DETAIL 1/0511 FOR INSTALLATION REQUIREMENTS. B O RTU -4, 216' X 91" X 85' HIGH ON SUPPORT RAILS. BY GENERAL CONTRACTOR, 4500L05. REFER TO DETAIL 1/651, FOR INSTALLATION REQUIREMENTS. RTU -5. 96' X 47 X48' HIGH WITH CURB, 950 LB5. REFER TO DETAIL 4/6511 FOR INSTALATION REQUIREMENTS. 8O RTU -6, 103" X0 X 49" HIH WTH CURB, 90 LB5. REFER TO 061011. 5 4 /6511 FOR G INSTALAOON R 9O RTU -7, 96° X 47" X 48" HIGH WITH CURB, 900 LBS. REFER TO DETAIL 4/651, FOR INSTALLATION REQUIREMENTS. 10 RTU -8, 103" X 50" 0 49' HIGH WITH RB, 0 LB5. REFER TO 061011 4/6511 FOR INSTALLATI REQ 1f TF -1, 143" X 61" X 58" HIGH ON SUPPORT RA/LS, BY GENERAL CONTRACTOR, 1625 LBS. REFER TO 0ETNL 1/6511 FOR INSTALLATION REQUIREMENTS. Q EF -1, 38' X 40" X 54° HIGH INCLUDING RAIL SUPPORTS, 540 LBS. REFER TO DETAIL 3/6511 FOR INSTALLATION REQUIREMENTS. 13 EF -2 49" X 51° X 72" HIGH INCLUDING RAIL SUPPORTS, 960 LBS. REFER TO DETAIL 3/6511 FOR INSTALLATION REQUIREMENTS. 14 KITCHEN REFRIGERATION UNIT, 72" X 60 X 60" HIGH WITHOUT CURB. 2400 LBS. FURNISHED AND INSTALLED BY OEI (UNIT SUPPUER). MECHANICAL CONTRACTOR SHALL PROVIDE TWO (2) 14" HIGH MINIMUM ROOF SUPPORT RAILS WITH FLASHING. SEE ARCHITECTURAL DRAWINGS FOR DETAIL. COUNTER FLASHING BY MECHANICAL CONTRACTOR. HELD VERIFY EXACT CURB SIZE PRIOR TO INSTALLATION. ALL REFRIGERANT PIPING 15 FURNISHED AND INSTALLED BY DLL. • ICE MACHINE AIR COOLED CONDENSER U911, EACH APPROXIMATELY 30" X 30' X 36' HIGH WITHOUT CURB, 110 LBS. FURNISHED BY ICEMAKERS AND INSTALLED BY DEL. MECHANICAL CONTRACTOR SHALL PROVIDE FOUR (4) 14" HIGH MINIMUM INSULATED ROOF CURBS AND TWO (2) ROOF OPENINGS. REFRIGERANT PIPING BY DEL. ROOF CURBS SHALL BE A FULL PERIMETER TYPE CURB WITH AN INSULATED SHEETMEFAL CAP AND FLASHING, COUNTER - FLASHING BY THE ROOFING CONTRACTOR. RELD VERIFY EXACT REQUIREMENTS PRIOR TO INSTALLATION. • 2 TON AIR COOLED CONDENSING UNIT, APPROXIMATELY 34" X 24 X 18" HIGH WITHOUT CURB, 150 LBS. UNIT IS FURNISHED BY ICM. MECHANICAL CONTRACTOR SHALL PROVIDE A 14" HIGH MINIMUM INSULATED ROOF CURB, ROOF OPENING AND REFRIGERANT PIPING. INSTALL PIPING FROM OUTDOOR UNIT TO INDOOR HEAT EXCHANGER MOUNTED ON !CIA SKID. ROOF CURB SHALL BE A FULL PERIMETER TYPE CURB WITH AN INSULATED SHEETMETAL CAP AND FLASHING WITH COUNTERFLASHING BY THE ROOFING CONTRACTOR. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO INSTALLATION. 0 GREASE TIGHT ACCESS PANEL 0 EX150110 CONDENSING UNIT AND PIP1140 TO REMAIN. 19 16/32 COMBUSTION AIR INTAKE. REFER TO DETAIL 10/14511 FOR INSTALLATION REQUIREMENTS. . 170 WATER HEATER VENT UP THROUGH ROOF. REFER TO DETAIL 12/9511 FOR INSTALLATION REQUIREMENTS. 0 14 "9 WATER HEATER VENT UP THROUGH ROOF. REFER TO DETAIL 12/9511 FOR INSTALLATION REQUIREMENTS. INSTALL REFRIGERANT PIPING PER MANUFACTURERS RECOMMENDATIONS. REFER TO DETAIL 7/0511 FOR INSTALLATION REQUIREMENTS. ® REFRIGERANT PIPING DOWN THROUGH ROOF. REFER TO DETAIL 8/9511 FOR INSTALLATION REQUIREMENTS. O . REFER TO DETAIL 4/6511 FOR INSTALLATION REQUIREMENTS. o) REFER TO DETAIL 5/M511 FOR INSTALLATION REQUIREMENTS. EXISTING ROOFTOP EQUIPMENT TO BE REMOVED BY LANDLORD. EXISTING MALL EQUIPMENT TO BE REMAIN. EXISTING ROOF DRAIN TO REMAIN. VERIFY EXACT LOCATION OF GAS METER WITH GAS COMPANY & THE MALL REPRESENTITNE. GAS SERVICE AND METER BY GAS COMPANY. 3,900 CFH 2 P5) DISCHARGE PRESSURE. PROVIDE SHUT -OFF VALVE ON METER DISCHARGE. 7' ( LINOWN THROUGH ROOF 006 GAS CONTI G UATION E D 0010 DETAIL 3/0510. . -SEE DRAWING M130 101" GA 5 (G) LANE DOWN THROUGH OF. SEE DRAWING M110 31 FOR C0 AND DETAIL 3/951 REFER ATOR 1O . DETAIL 4/9510 FOR PIPING AT GAS PRESSURE REGUL 3 ET AIL " VENT 3/9510. THROUGH ROOF. SEE DRAWING M110 FOR CONTINUATION & D 4 4" ETAIL VENT 3/051 THROUGH 0. ROOF. SEE DRAWING M130 FOR CONTINUATION & D NOTE: ALL UNIDENTIFIED ROOFTOP EQUIPMENT INDICATED WITH DASHED LINES IS EXISTING, AND LOCATIONS ARE APPROXIMATE. 1 NOTE: ALL ROOFING WORK ASSOCIATED WITH THE INSTALLATION OF NEW MECHANICAL EQUIPMENT TO INCLUDE CURBS, ROOF OPENINGS FOR DUCT PENETRATIONS, PIPING ETC... SHALL BE PERFORMED BY THE LANDLORD'S APPROVED ROOFING CONTRACTOR AT THE TENANT'S EXPENSE. CirY 0 1 2' ii ) 9YNNYrrer Date Na. Dale Description Cuningham Group Architecture Interior Design Planning Construction Services 201 Main SL SE. Suite 325 Minneapolis, MN 55414 Telephone: 612 -379 -3400 Facsimile: 612-379-4400 Internet: vmw.cuninghom.corn RAINFOREST CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS ROOF HVAC /PLUMBING PLAN REC51VE0 5000FIUISA0IA SEP 1 1 ((93 PERMITCENTER M300 7/2/88 CAP116 1111B \Dllf FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA OCCUPANCY HAZARD CLASSIFICATION SYSTEM TYPE DENSITY GPM /SOST. REMOTE AREA SOFT MAX. AREA S OFT. /HD HOSE DEMAND GPM SPRINKLER TEMP.. RATING 'F SPRINKLER HEAD TYPE SPRINKLER HEAD FINISH TNAINING/L0G(ERS, WOMEN'S AND MEWS REESTROOMS, FRONT OFFICE, ACCT. OFFICE. C.M. OFFICE, ORDINARY WET 0.20 3000 130 250 155 SEE SPECIFICATIONS SEE SPEC. AREAS ABOVE CBGNG ORDINARY WET 0.20 3000 130 250 200 SEE SPECIFICATIONS SEE SPEC. AREAS BELOW GREENERY CEILING ORDINARY GROUP 2 WET 0.20 3000 130 250 155 SEE SPECIFICATIONS SEE SPEC. ALL REMAINING AREAS, MECHANICAL, ELECTRICAL ORDINARY GROUP 2 WET 0.20 3000 130 250 SEE SPECIFICATIONS SEE SPEC. KITCHEN HOOD WITH PRE -PIPED SPRINKLER SYS ARCHED AQUARIUM \ j) 6 VYAI--01 n FIRE PROTECTION PLAN O NORTH \v" • 81114 CEILINGS 155. 4,4TH0UT CEILINGS 200 KEY NOTES O t INSTALL SPRINKLER HEADS IN MUSHROOM CEIUNG AND ABOVE MUSHROOM AT HIGHER CEIUNG. REFER TO ARCHITECTURAL REFLECTED CEIUNG FOR LOCATION OF SPRINKLER HEADS IN MUSHROOM. O INSTALL SPRINKLER HEADS AROUND THE PERIMETER OF THE °LULUS IN ORDER TO PROTECT BELOW. ADD CONCEALED HEADS IN THE OCULUS AS NECESSARY TO PROVIDE ADEQUATE SPRINKLER COVERAGE PER NFPA 13. SPRINKLER HEAD LAYOUT IS TO MINIMIZE THE NUMBER OF HEADS REQUIRED IN THE OCULUS SUBMIT OCULUS HEAD LAYOUT TO ARCHITECT PRIOR TO HYDRAULIC DESIGN AND SUBMITTAL TO THE ENGINEER. SPRINKLER HEADS MAY BE REQUIRED IN EXCESS OF CODE AS DETERMINED BY REVIEW BY THE ARCHITECT. HEADS ARE NOT TO BE CENTERED IN THE OCULUS. 0 INSTALL SPRINKLER HEADS ALONG THE AQUARIUM ARCHWAY IN ORDER TO PROVIDE COVERAGE BELOW THE ARCHWAY PER NFPA 13. O CONNECT PRE -PIPED HOOD 4,1114 1 PROTECTED COLD WATER (PCW) LINE. INSTALL LOCKING VALVE FURNISHED BY CAPTVEMR. SEE KITCHEN EQUIPMENT DRAWINGS FOR EXACT LOCATIONS. SEE DRAWING 1/8130 FOR MORE INFORMATION. O GREENERY CEILING AREAS. REFER TO SPECIFICATIONS. REFER TO ARCHITECTURAL REFLECTED CEIUNG PLANS FOR HEIGHTS. GENERAL NOTES 1. COORDINATE SPRINKLER HEAD LOCATIONS WITH ARCHITECTURAL EFFECTS HANGING FROM THE CEIUNG. SEE ARCHITECTURAL DRAWINGS FOR CEILING DETAILS. 2. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE ARCHITECTURAL DRAWINGS AND C00RDINAIING SPRINKLER HEAD LOCATIONS W H THE ARCHITECTURAL EFFECTS IN ORDER TO COMPLY WITH NFPA 13. 3. INSTALL DRY PENDENT HEAOS IN ALL COOLERS & FREEZERS. 4. ANY EXPOSED PIPE AND FITTINGS SHALL BE STAINLESS STEEL IN KITCHEN AREAS. 5. SEE SPECIFICATION SECTION 15330 FOR KITCHEN SYSTEMS. FURNISH AND INSTALL 1 PROTECTED COLD WATER (PCW) SUPPLY PIPING TO THE CONTROL PANEL , AND FROM THE CONTROL PANEL TO 114E PRE -PIPED EXTINGUISHING SYSTEM IN 114E HOOD. CONTACT THE KITCHEN HOOD MANUFACTURER FOR SUPPLY PIPE SIZING AND EXCAT LOCATION OF PIPING CONNECTIONS. A MINIMUM OF 30 P51 MUST BE AVAILABLE AT THE CONTROL PANEL CONNECTION. OCT 1 6 1'398 Date: Seel Raba .. Seel Ms RAINFORE T CAFE Cuningham Group Architecture Interior Design Planning Construction Services 201 Main 51. S.E Suite 325 Minneapolis, MN 55414 Telephone, 612 -379 -3400 Facsimile: 612- 379 -4400 Internet: www.cuninghom.com 7/2/98 Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS FIRE PROTECTION RHO7VE0 CDYCFIU19VILA SEP 1 9 t!? PEFWRCC-tfTER M400 MISC. EQUIPMENT SCHEDULE MANUFACTURER: - UNIT N0. MFR. & MODEL N0. LOCATION AREA SERVED FAN DATA CAPACITY MOTOR DATA REMARKS CFM SP BTUH AMR' KW BHP HP RPM V-0-Hz "_ B80- 180 G86081600 -7 -R3 HABITAT ROOM 106 HABITAT ROOM 106 3000 0.75 - - - 0.74 1.0 981 480 -3 -50 - y..._ +" T - Tfq- 920C4 200 0pp ROOF & RETAIL DINING, BAR _ - 142 85' F - - MCA 110 1100 480 -3 -60 WITH HOT GAS BYPASS ✓EHCrt I90 HABITAT ROOM 106 HABITAT ROOM 108 ,3400 - 51195 - 15,0 - - - 460 -3-60 }STAG£ + °95 -2: RDEECO WA STORAGE 104 RETAIL OFFICE 105 125 _ 3413 _ 1.0 - - - 208 -1 -60 2-STAGE E1R1-1: BERKO HUHAA-1048 MECHANICAL ROOM 117 MECHANICAL ROOM 117 650 - 34130 - 100 - 1/30 1600 450 -3 -60 - P - BEAKO EFCH-RE 546 CORRIDOR 118 CORRIDOR 118 285 - 8826 _ 2.0 - - - 208 -3-60 INSTALL IN LAY -IN CEILING 4QA( -3 80900 FFgRRE548 CORRIDOR 127 CORRIDOR ,27 265 - 6826 - 2.0 - - - 208 -3 -60 INSTALL IN LAY -IN CEILING 150 122 31 1850 TYO STAGE GAS HEAT. 0 - 25 R MANUAL OUTSIDE AIR DAMPER, 900 CNA. 1_4 1PANE NO3500410 ROOF KITCHEN, S10R. k MAINT. 134110E 12225 100 - - 615 5.78 100 -1 • TJERNLUND I MECHANICAL ROOM 117 MECHANICAL ROOM 117 386 - 79.2 67.4 60.6 58.5 4.25 1725 120 -1 -60 - -2 ., TJERNLUND I MECHANICAL ROOM 117 MECHANICAL ROOM 117 4511 TWO SAGE GAS HEAT. 0 - 25 3 MANUAL OUTSIDE AIR DAMPER, 2500 OEM. TRANE W00495415 - - - 0.25 1725 120 -1 -60 - 0.55 0.75 3 15 12.6 273 - 77.2 63.5 55.6 53.7 38.7 47.5 4 C HAUST FAN SCHEDULE MANUFACTURER: GREENHECK MODEL N0. LOCATION AREA - SERVED FAN DATA MOTOR DATA REMARKS WHEEL TYPE CFM ESP TSP RPM BHP HP V-.01-H2 M.-20 000E KITCHEN HOOD ALUM. 4250 - 3.0 1548 3.17 5.0 480 -3 -50 UL 762 AND NSF LISTED SWB -30 ROOF - -. KITCHEN HOOD ALUM. 9500 - 3.0 1071 6.36 10.0 480 -3 -60 UL 782 AND NSF USTED CUBE 140 -5 -124 ROOF ' D154494 NINE ALUM. 1500 - 0.75 1194 0.38 0.50 480 -3-60 WITH ROOF CURB GB- 130 -4-R3 ROOF PUBLIC RESTR0080 ALUM. 800 - 0.50 1045 0.109 0.25 120 -1 -60 WITH ROOF CURB GB- 120 -4 -R3 ROOF FILTRATION AND JANITOR'S ROOMS ALUM. 800 - 0.50 1045 3.108 0.25 120 -1 -80 MN ROOF CURB 0-55 -8 .ROOF ' EMPLOYEE -- RESTROOMS ALUM. 200 - 0.375 1115 0.024 0.25 120 -1 -60 VIN ROOF CURB 03- 220 -7 -114 ROOF ' - - 1HABTTAT ROOM ALUM. 3500 - 0.375 574 0.42 0.50 480 -3-60 WITH ROOF CURB G -90 -G ROOF SOMAT ROOM AND MAINT. ENG. OFFICE ALUM. 350 - 0.375 1220 3.042 0.25 120 -1 -80 WITH ROOF CURB 97.9 121.8 10 61 53 150 122 31 1850 TYO STAGE GAS HEAT. 0 - 25 R MANUAL OUTSIDE AIR DAMPER, 900 CNA. 1_4 1PANE NO3500410 ROOF FLOOR DRAIN & AREA DRAIN SCHEDULE TENANT MAKE UP AIR MANUFACTURER: JOSAL FLOOR DRAIN NO AREA DRAIN N0. MODEL N0. TRAP SIZE REMARKS F51 - SERIES 49050 -AS SEE PLAN 12 °x12" - FLOOR 9NK 51114 HALF COVER GRATE FS2 - SERIES 49850 SEE PLAN FLUSHING FLOOR SINK F53 - SERIES 49120 SEE PLAN 1816%1614 - FLOOR SILK WIN HALF COVER ORATE FD1 - SERIES 30000 SEE PLAN FLOOR DRAIN WITH ADJUSTABLE COVER HEIGHT N2 - SERIES 30000 -4 SEE PLAN FLOOR DRAIN WITH TRAP PRIMER CONNECTIONS FD3 - SERIES 30000 -E2 SEE PLAN FLOOR DRAIN M11H FUNNEL N4 - SERIES 76010 SEE PLAN 1R88CH DRAINS 12" WOE LENGTH OF ORATE ON PLAN TENANT SPACE AIR BALANCE TENANT MAKE UP AIR CFM TENANT EXHAUST AIR CFM ROOFTOP AND MAKE UP AIR UNITS 16700 HABITAT ROOM 3500 HD BHP KITCHEN 15250 SIB TOTAL ROOFTOP AND AND MAKE UP AIR UNITS 16704 TOILETS 1000 180 H6R 5 FILTRATION It JANITOR'S ROOMS 800 MAKE UP AR i2d1 MALL COMMON AREA 4200 SOMAT ROOM 350 CP -2 Big SERIES 80 MECHANICAL ' ROOM i t] 120" HNR 10 20 - 1/4 TOTAL MAKE UP AR 20900 TOTAL EXHAUST AIR 20900 6000 1.00 - - PUMP SCHEDULE MANUFACTURER: BELL ac GOSSETT UNIT NO. MFR.& MODEL N0. LOCATION AREA SERVED FLOW DATA MOTOR DATA REMARKS Cm HD BHP HP RPM 0 CP -1 Bee SINES 80 MECHANICAL. ROOM 117 180 H6R 5 f0 - 1/4 .1750 115 -1-80 - CP -2 Big SERIES 80 MECHANICAL ' ROOM i t] 120" HNR 10 20 - 1/4 1750 115 -1 -60 - DINING k PAR 6000 1.00 - - 928 3.97 5 3 15 17.5 343 - 72.5 62.4 56.7 54.2 1024 143.5 5 12.5 62 81 gOOFTOP AIR HANDLING UNIT SCHEDULE MANUFACTURER: DIANE IIT MFR. & D. MODEL N0. LOCATION AREA SERVED CFM SUPPLY FAN DATA OX COOUNG COIL DATA GAS FURNACE DATA UNIT 0 MCA _60 460 -3 - l)OF ^aT IYBm R 0.8ffi REMARKS ESP TSP V klwn , RPM BHP FAN HP NO. TONS FINS/ NCH FACE AREA FACE EL APD EAT LAT (UNIT) STEEL S MBH TOTAL MBH TOTAL TONS EAT LAT INPUT OUTPUT j 090 1 -1 Y01 ROOF ROOF DINING k PAR 6000 1.00 - - 928 3.97 5 3 15 17.5 343 - 72.5 62.4 56.7 54.2 1024 143.5 5 12.5 62 81 150 122 34 S0 .0 STAGE CAS HEAT, 0 - 25 R MANUAL OUNCE 4R DAMPER, 1000 CFI. 1 -2 10015 0416 800E DINING 0000 1.00 - - 928 3.97 5 3 15 17.5 343 - 72.5 62.4 56.7 54.2 1024 143.5 125 62 81 150 122 34 ISO TWO STAGE 8A5 HEAT. 0 - 25 R MANUAL OUTSIDE AIR DAMPER, 1000 CFAI. 1 -3 YC012 C4L8 ROOF RETAIL 5000 TOO - - 651 284 5 3 15 17.5 285 - 74.2 62.8 56.0 54.5 97.9 121.8 10 61 53 150 122 31 1850 TYO STAGE GAS HEAT. 0 - 25 R MANUAL OUTSIDE AIR DAMPER, 900 CNA. 1_4 1PANE NO3500410 ROOF KITCHEN, S10R. k MAINT. 134110E 12225 100 - - 615 5.78 10.0 2 14 31.67 386 - 79.2 67.4 60.6 58.5 245.4 353.5 30 60 86.9 350 283.5 81-23 4511 TWO SAGE GAS HEAT. 0 - 25 3 MANUAL OUTSIDE AIR DAMPER, 2500 OEM. TRANE W00495415 ROOF ROUT OFRR'S, BRKRN EMPL TOILETS 1660 0.20 - - 850 0.55 0.75 3 15 12.6 273 - 77.2 63.5 55.6 53.7 38.7 47.5 4 552 99.9 90 23 118 ..° NQASI FULL ECONOMIZER AND BARMIER. 9ELIE0 (400 LHT2 OA Y9161W) 1 -6 MANE 003074C400 ROOF FX ROOM 2485 0.80 - - 1002 0.97 1 3 15 8.33 206 - 75.7 63.2 58.6 54.2 51.2 65.1 6 _ _ _ _ ,7 900 INCLUDE NIL ECONOMIZER AND BAROMETRIC RELIEF (2110 CM OA WHINY) 1-7 THANE 1CDU49C40G ROOF.1 61.0. 99 5HOW PUMP ROOMS 1890 O.6fi - 850 0.60 0.75 3 15 7.9 275 - 76.5 63.7 56.7 54.8 41.2 50.2 4 - - - - 11.8 900 INCLUDE NIL ECOIO 1204 AND BAROMETRIC RELIEF (s50 GFM OA MinIUM) I3 1RANE TCD0740400 ROOF ELECTRICAL ROOM 2400 060 - - 989 0.92 1 3 15 7.9 275 - 74.8 62.6 55.4 53.1 50.4 64.8 6 - - - - 17,8 950 MIME NIL ECONOMIZER AND BAROMETRIC RELIEF 200 6 OA Y O MN.) iRANE 0-1 CRAA4059100 ROOF DINNINC.BAR MAK RETAIL AIR 6000 1.00 _ _ 725 1.62 3 4 10 10.9 553 ass 55 68 619 61 137 142 10 2 52 400 320 5.25 2100 $Ei SUPPLY AR DAMPERS FOR 2500 cm TO RlS -1, 2509 GFY TO RIU-2 AND 1000 KM TO RN -3. I RAWE AH0A4000F000 RODE pICH6N N00D MAKE UP AIR 10500 0.60 - - 285 5.67 7.5 - - - - - - - - - - - - - - - - - 1625 FORMER YOTOf�)D OUTSIDE AR AND RETURN AIR DAMPERS, SET 0.0. DAMPER 4000 6M. PROVIDE Ml'R 14' HIGH ROOF CURB. 3RILLE, REGISTER & DIFFUSER SCHEDULE MANUFACTURER: a1 IPE FUNCTION CONSTRUCTION TYPE MAX. N.C. MODEL NO. NOMINAL SIZE REMARKS A SUPPLY DIFNSER STEEL 35 TIARA SEE PLANS WITH OPPOSED BLADE DAMPER B STEEL 35 RASA 24"x24" 1AY -IN FULL FACE DIFFUSOR SEE PLANS FOR NECK SIZE SUPPLY DIFFUSER BI SUPPLY DIFFUSER STEEL 35 TM5A 24524"/12"x12" FACE SURFACE MOUNTED W DAMPER. SEE PLANS FOR NECK 9Z AND FACE SIZE C ALUMINUM 30 RHV (SEIHO) Co 119TH OPPOSED BLADE CAMPER SUPPLY Remits D SUPPLY REGISTER ' ALUMINUM 35 300 R SEE PLANS MMT4 OPPOSED BLADE DAMPER 1 RETURN/EXHAUST/TRANSFER GRILLE ALUMINUM 35 350 R SEE PLANS - F RETURN/EXHAUST/TRANSFER GRILLE � 30 50 FF SEE PLANS FRAME TYPE 3 LAY -IN, 1 /2 "21/2 GRID G - ALUMINUM 30 350 FL SEE PLANS WITH OPPOSED BLADE DAMPER RETURN/EXHAUST REGISTER N SLOT DIFFUSER ALUMINUM 30 M -35 SEE PLANS - CONCENTRIC DIFFUSER ALUMINUM 30 1013 -0300 SEE PLANS - J SUPPLY DIFFUSER , 35 NASA 24.124" LAY -IN NLL FACE DIFNSER SEE PLANS FOR NECK SIZE K SUPPLY DIFFUSER ALUMINUM 30 TIARA SEE PLANS WITH OPPOSED BLADE DAMPER L SUPPLY DIFFUSER ALUMINUM 35 11454 24'.24712'212' FACE S URFACE MOUNTED W AMPER. SEE P LAN S FOR NECK SIZ AND FACE SIZE K SUPPLY DIFFUSER ALUMINUM 35 PM. 24"224" LAY -IN PERFORATED SUPPLY GRILLE LATER HEATER ;SCHEDULE MANUFACTURER: RHEEM MIT N0. MODEL N0. LOCATOR GAS INPUT MBH STORAGE CAPACITY, GALLONS ELECTRICAL DATA REMARKS HP V -4 -Hz 91 -1 078 -200 MECHANICAL ROOM 199 76 - 120-1-50 242 GPI AT 80 F TEMP. RISE 41-2 076 -200 MECHANICAL ROOM 199 76 - 120 -1 -60 242 OPH AT 60' F TEMP. RISE 41-3 076 -200. MECHANICAL ROOM 199 78 - 120 -1 -60 138 GPI AT 140' F TEMP. RISE 5 -4 676 -200 MECHANICAL ROOM 199 76 - 120 -1 -60 138 GPH AT 140' F TEMP. RISE 1 076 -200 : ROOM 109 76 _ - 120 -1 -60 138 GPH AT 140' F TEMP. RISE DOLING CAPACITIES ARE BASED ON 85' F AMBIENT AIR TEMPERATURE NITS SHALL HAVE SINGLE POINT POWER CONNECTION. ROHDE MINIMUM 14' HIGH ROOF CURBS FOR UNITS RTU-5 TIRO 600 -8. N -1 THRU RN -4, MAU -1 AND TF -1 SHALL BE SUPPORTED ON RAIL SUPPORTS JRNISHED AND INSTALLED BY GENERAL CONTRACTOR, REFER TO STRUCTURAL DRAWINGS. ECHANICAL CONTRACTOR SHALL PROVIDE ALL ROOF OPENINGS WITH CURBS FOR DUCT ENETRATONS, FLASHING. AND UNIT TIE DOWNS. .ECTRI0 SEANCE SHALL BE PROVIDED THROUGH ROOF CURB. T 2 3 4 5 5 7 8 PLUMBING FIXTURE SCHEDULE FIXTURE N0. FIXTURE TYPE WASTE VENT CW HW REMARKS P1 WATER CLOSET WATER CLOSET - HANDICAP URINAL P2 P3 P4 URINAL - HANDICAP NOT USED COUNTER LAVATORY COUNTER LAVATORY - HANDICAP WALL HUNG LAVATORY - 114101CAP NOT USED SHOWER PB NOT USED P11 55. DOUBLE SINK CAN WASH MOP SINK INTERIOR HOSE BIBB TRAP PRIMER P17 FLUSHING FLOOR SINK VALVE WASHD002I STATION THERMOSTATIC MIXING VALVE 4 ;1 THERMOSTAT. AIDING VALVE 116" 1K" 2' 2' 1N' 114' 1N' 15 45 TEMPERED SUPPLY TEMPERED SUPPLY TE85.05E0 SUPrLY (2) HEADS, MOUNT CONTROL VALVE OUTSIDE OF STALL 01110E-2 Y OUTLET CITY 0 APPRCV OCT 1 6 1353 CIPL R91V14a s Date: Cunigham Group Architecture Interior Design Planning Construction Services 201 Main SI. 5.E. Suite 325 Minneopdis, MN 55414 telephone: 612 -379 -3400 Facsimile: 612- 379 -4400 Internet: www.cuninghom.com No. Date 0580E ion 7/2/90 Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS Swat Tile MECHANICAL SCHEDULES 159-111/12 CRY OF t UKWILA SEP 1 1 1593 PERMITCENTER Sheet Nlrtber M500 GAS SUPPLY ( PIPINC SYSTFM4 REGULATOR SHUT —OFF VALVE TEE 244" C BY —PASS VAL LEFT OPEN FULL PORT BALL VAL (TYP) NOTE: SEE SPECIFICATION SECTIONS 15140 AND 15260 FOR ADDITIONAL REQUIREMENTS HANGER ROD LOCKING NUT SUPPORT NUT ADJUSTABLE GLENS HANGER BALL VALVE (TYP) CHECK VALVE (TYP) CUT INSULATION AT HANGER STRAPS PIPE INSULATION — EXTEND FULL SIZE THRU HA' WOOD BLOCK — SEE SPECIFICATIONS METAL INSULATION PROTECTION SHIELD (12° MINIMUM LENGTH) O CLEVIS HANGER DETAIL NO SCALE O NSULA1ID PIPING) 24° MIN. � VENT G00SENECK ( TEE DIRT TRAP POCKET O GAS PRESSURE REGULATOR DETAIL NO SCALE 211 CW LEFT CLOSED 214 CW O ROUGH -IN FOR WATER SOFTENERS 7 NO SCALE 2 95' SHW 215" 120' SHW Y" 120' CHW EXPANSION TANK — AMTROL MODEL 5T -12 —C. 4.7 GALLON RECIRCULATING PUMP (CP 2) THERMOSTATIC MIXING VALVE (P19) 214 CW 3 GAS Al" CONCRETE PAD 81 MECHANICAL CONTRACTOR WATER HEATER DETAIL 111 NO SCALE PLUG 214" C DOMFSTIC HOT WATER PIPING SYSTEMS ONLY TO UNIT 211" LINES CAPPED AT 7' -0" A.F.F. PIPE (TYPICAL) METAL INSULATION PROTECTION SHIELD (12 MINIMUM LENGTH) UNINSULATED PIPE SPACING 2 1 II S � 9 c NU LOCKING T 11 1 1 iii - (TYPICAL) It ' HIGH DENSITY INSULATION INSERT (HOT PIPING) OR WOOD BLOCK (COLD PIPING) — SEE SPECIFICATIONS O 2 TRAPEZE HANGER DETAIL NO SCALE 8"0 SUPPY AIR DUCT TYP OF 4 LOCATE IN DUCT NEAR SLOT DIFFUSER TYP OF 4 BALANCING DAMPER, i,I EXHAUST PLENUM. PROVIDE FLANGE AROUND PERIMETER TO SUPPORT TYPE F LAY—IN EXHAUST GRILLE. REFER TO ARCHITECTURAL DETAILS. 4 �� ® BIRD PERCH TYP V DETAIL 5 NO SCALE 24" 0 20" EXHAUST DUCT. SEE M200 0' ON HANGER ROD (1YPICAL) 044151. SEE SPECIFICATION SECTIONS 15140 AND 15260 FOR ADDITIONAL REQUIREMENTS CONDENSATE DRAIN. PIPE TO SPLASHBLOCK ON ROOF EQUIPMENT DRAIN PAN O 8 CONDENSATE TRAP DETAIL NO SCALE AO 180' CHW 1V° 180' SHOD EXPANSION TANK — AMIROL MODEL ST- 30V —C, 12.5 GALLON RECIRCULATING PUMP (CP -1) FLOW FITTING (rep) GAS COCK (TYP) UNION (TIP) DIRT LEG (TYP) SUPPORT NUT (TYPICAL) STAWE EQUAL TO TWO TIMES THE 7:EGATh£ STATIC PRESSURE OF THE UNIT NOEL 1. FLUES NOT SHOW FOR CLARITY. SEE M110 AND 9200 OCR FLUES & CONTINUATION OF PIPING 2. PROVIDE SUPPORT BRACKETS FOR EXPANSION TANKS. 3. ALL PIPING SHALL BE ABOVE WATER HEATER AND OUT OF THE WAY DURING A WATER HEATER REPLACEMENT. WATER TIGHT & HOSE CLAMP BY MECHANICAL GAS PIPE OR PLUMBING VENT THRU ROOF O PIPE PENETRATION THRU ROOF NO SCALE (GAS AND PLUMBING VENT PIPING) STAINLESS STEEL COLLAR ADAPTER 316 TYP 55 ONE GUAGE HEAVER THAN THE 'PS' STACK UNER. 'PS' TYPE FLUE O 9 DRAFT INDUCER FLUE DETAIL NO SCALE rn q-t--1 HANGERS (TYP 241024" FILTER RACK WITH FILTERS CONTINOUS HIGH TEMPERATURE SEALANT PER MANUFACTURERS INSTALLATION INSTRUCTIONS GAS PIPE OR PLUMBING VENT — REFER TO DRAWING FOR SIZES AND LOCATIONS WATER TIGHT COPPER SHROUD ROOF RETAINER FLEX CONNECTOR MOUNT IN LINE DRAFT FAN IN STAINLESS STEEL COLLAR ADAPTER TO HABITAT ROOM GREENERY CEILING EHC—I DUCT HEATER O HABITAT ROOM SUPPLY AIR FAN DETAIL NO SCALE Cuvgham Group Architecture Interior Design Planning Construction Services 201 Main St, 5.1. Suite 325 Minneapolis, MN 55414 Telephone. 612- 379 -3400 Facsimile: 612- 379 -4400 Internet: www.cuninghom.cam 0410 Comm. No. Southcenter Mall Tukwila, WA Seal TWe MECHANICAL DETAILS Seat Wilber 615EIVED CR Y OF1U KWILA SEP 1 1 1393 PERMIT CENTER M510 7/2/90 CAP115 CONSTRUCTION DOCUMENTS ROOF FLEX CONNECTION ECONOMIZER ROOF BAR JOIST 18' MINIMUM GASKETINC BY MECHANICAL 14" MINIMU 1" MINIMUM COMBUSTION AIR DUCT, SEE HVAC PLANS FOR SIZE AND CONTINUATION DX COOING COIL. SEE DETAIL FOR PIPING BURNER SECTION N. REFER TO STRUCTURAL DRAWINGS FOR UNITS BEING INSTALLED BY MECHANICAL CONTRACTOR ON STRUCTURAL SUPPORT RAILS. STRUCTURAL RAIL SUPPORTS ARE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. ALL CURBS, ROOF OPENINGS FOR DUCT PENETRATIONS. FLASHINGS, UNIT TIE DOWNS AND OTHER REQUIRED MATERIALS SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. FAN SECTION ROOFTOP AIR HANDLING UNIT CONDENSATE DOWN TRAP TO BE TWO TIMES THE NEGATIVE STATIC PRESSURE BY MECHANICAL CONDENSATE DRAIN. PIPE TO ABOVE SPLASH BLOCK FURNISHED BY MECHANICAL UNION (TYP) DIRT LEG 1 O MAKE UP AIR UNIT - DETAIL NO SCALE NOTE' TYPICAL FOR UNITS RN -1 THRU RN -4, MAU —I AND T -1. 4 O ROOFTOP UNIT DETAIL NO SCALE L TYPICAL FOR UNITS RPJ -5 THRU RN -8. NOTE 1. SUPPORT REQUIRED EVERY 10' -0' 0.0. AND AT CHANGE IN DIRECTION. 2. INCREASE HEIGHT AS REVD FOR ROUTING ABOVE ROOF MOUNTED ACCESSORIES SUCH AS EXPANSION JOINTS. 3. PVC PIPE SLEEVE SHALL BE THE NEXT SIZE PIPE DIAMETER LARGER THAN THE OUTSIDE DIAMETER OF THE PIPE. COMBUSTION AIR INTAKE W /BIRDSCREEN SOLDER ALL SEAMS WATERTIGHT BOLT 4 VIBRATION CONDENSATE DRAIN. PIPE ISOLATORS TO TO ABOVE SPLASHBLOCK. ANGLE IRON FRAME SPLASHBLOCK FURNISHED BY MECHANICAL CONTRACTOR O ROOF PIPE SUPPORT DETAIL NO SCALE (GAS AND GRANT PIPING) O COMBUSTION AIR INTAKE DETAIL 10 ND ecaE /� YY\ [A 7,/11 - 7/ J V BANK FILTER SECTION MOTORIZED INTAKE AIR DAMPER INTAKE H000 WITH BIRD SCREEN SUPPORT RAILS BY GENERAL CONTRACTOR, CONDENSER COIL GASKET COUNTER FLASHING INSULATED CURB BY MECHANICAL FLASHING AND CANT STRIP BY MECHANICAL METAL DECK WOOD BLOCKING BY MECHANICAL SAME THICKNESS AS ROOF INSUL RIGID INSULATION PVC PIPE SLEEVE 1 WIDE 20 GA. GALVANIZED STEEL PIPE CUP FOR THE PVC SLEEVE (2) 4'x4° TREATED WOOD BLOCKS HUMANE PAD 18'918' (MIN.) ROOFING GOOSENECK INTAKE COUNTERFLASHING BY MECHANICAL CONTRACTOR CURB & FLASHING BY MECHANICAL CONTRACTOR W000 BLOCKING (SAME THICKNESS AS ROOF INSULATION) BY MECHANICAL CONTRACTOR MOTORIZED COMBUSTION AIR DAMPER ROOFING 12' EXTENDED BASE CONNECT DUCT AT DAMPER SECTION PREFAB. ROOF CURB W/FIBERGLASS INS. TO MATCH EXH. FAN BY MECHANICAL CONTRACTOR 14" MINIMUM 1/2 DEEP MIN. DRIP PAN — SOLDER ALL SEAMS WATERTIGHT — PROVIDE 1/2' MASTIC COATING ENCLOSE DRIP PAN 1WTH EXTERNAL INSULATION 14' MINIMUM ROOF EXHAUST FIN MOTOR® DAMPER GASKETTNG BY MECHANICAL CONTRACTOR F1A9150 & COUNTER FLASHING BY MECHANICAL CONTRACTOR WOOD BLOCKING (SAME PISULATION) BY MECHANICAL CON1HACTOP. 111181,41.0.1 INSULATED DUCT(S) — SEE SPECIFICATIONS EXHAUST DUCT(S) — SEE PLANS FOR SIZE EXHAUST PLENUM O ROOF MOUNTED EXHAUST FAN DETAIL NO SCALE OP-BLAST TYPE) EXTENDED BASE CONNECT DUCT AT DAMPER SECTION INSULATED CURB BY MECHANICAL EXHAUST FAN MOTORIZE DAMPER GA5KEBNG BY MECHANICAL FLA9IHG AND COUNTER FLASHING BY MECHANICAL CONTRACTOR W000 BLOCKING (SAME THICKNESS AS ROOF MAIL) BY MECHANICAL 1' MRBMUM EXHAUST DUCT(5) INSULATED DUCT(S)— SEE SPECIFCATIONS 1 1/2' DEEP MIN. DRIP PAN MASTIC COATING 7� ENCLOSE DRIP PAN — SOLDER ALL SEAMS WATERTIGHT — PROVIDE 1/2' N1 TIi EXTERNAL INSULATION °���"�G ^+"m� ° °�"�-� e EXHAUST PLENUM O ROOF MOUNTED EXHAUST FAN DETAIL 5 NO SCALE PROVIDE FLEXIBLE SEALANT AROUND ALL PENETRATIONS INSULATED HEAVY GAUGE SHEET METAL CAP AND COUNTER FLASHING BY MECHANICAL CONTRACTOR 2' BOARD INSULATION CURB, FLASHING AND COUNTERFLASHING BY MECHANICAL CONTRACTOR ROOF DECX O PIPING THROUGH ROOF CURB DETAIL 8. NO SCALE UNIT BASE AND PANEL. SET LEVEL COUNTERFLASHING BY MECHANICAL CONTRACTOR FLASHING BY MECHANICAL CONTRACTOR CANT STRIP AND BLOCKING BY MECHANICAL CONTRACTOR 11 ROOFTOP UNIT CURB DETAIL NO SCALE NM TYPICAL FOR UNITS RN -5 THRU RN -8. VIBRATION ISOLATOR PAD AND GASKET AS REQUIRED NAILER STRIP BY MECHANICAL CONTRACTOR 14' HIGH INSULATED STEEL ROOF CURB BY MECHANICAL CONTRACTOR CURB. INSULATION BY MECHANINCAL CONTRACTOR STEEL CHANNEL SUPPORT BY G.C. WHEN REQUIRED. REFER TO LANDLORDS CONSTRUCTION MANUAL STANDARDS ROOF DECK FLEXIBLE DUCT/FAN CONNECTION 8110 WEATHER PROTECTION 0011AR GREASE 11941 ACCESS 0018. TYPICAL PROVIDE AT LEAST 3 DIAMETERS OF STRAIGHT DUCT TO FAN INLET PROVIDE A P09TVELY SEALED ACCESS DOOR WITH ADJUSTABLE TENSION LATCHES. FLASHING & COUt4TER FLASHING BY MECH. ONTRACTOR. EXHAUST DUCT O 3 RANGE HOOD EXHAUST FAN DETAIL NO SCALE 1HFERMOSTAIIC MANSO1 VALVE (TYP.) SIGHT CLASS (TIP.) SOLENOID VAL (TYP.) FILTER DRIER WNIH VALVE BYPASS (TYP.) REFRIGERATION PIPING. VALVES AND ACCESSORIES SHALL BE SIZED AND INSTALLED PER EQUIPMENT MFR'S INSTALLATION INSSRUCi1ONS. RIGID S.A. DUCT SEE PLAN FOR SIZE DUCT HANGER (TYPICAL) 12 STORM COf1AR 4 '► •a 111 �''l TRANSITION TO BE FLAT ON BOTTOM TRANSITION TO HPUN66D PITCH OWN T P R FT. TOWARD DUCT RISER PITC DN O REFRIGERATION PIPING DETAIL NO SCALE O 9 DUCT CONNECTION TO DIFFUSER NO SCALE 1/2" MR SPACE TALL CONE FLASHING PROVIDE FABRICATED WATERTIGHT CURB PER LANDLORD'S CONSTRUCTION MANUAL STANDARDS INDUCED DRAFT FAN INSTALL PER MANUFACTURERS RECOMMENDATIONS REFER TO DETML 9/)4510 FOR MORE INFORMATION UL -0STED 4ENT FLUE FROM GAS EQUIPMENT /) NO SCALE 2' FAN HOUSING DRAIN BOLT 4 VIBRATION ANGLE IRON TO ANGLE FRAME RAIN CAP PROVIDE CUSTOM FIT GREASE GUARD CONTAINMENT SYSTEM. CONTAINMENT SYSTEM SHALL EXTEND A MINIMUM OF 24" BEYOND ALL SIDES OF THE FAN COMPONENTS. CONTRACTOR SHALL PROVIDE REQUIRED SYSTEM INFORMATION TO SUPPUER FOR FABRICATION. MINIMUM 12' UNDER FELTS ALL AROUND CLEARANCE AS REO'D. FOR ROOF MATERIAL PROVIDE A 24' HIGH (MIN.) DISCHARGE STACK WEATHERPROOF DISCONNECT BY DIVISION 10 RODE SUPPORT RAILS FOR EXHAUST FAN BY MECHANICAL CONTRACTOR MOTOR & BELT ASSEMBLY WITH WEATHER —PROOF COVER EVAPORATOR COIL CONDENSING UNIT VIBRATION ISOLATORS ROOF SUPPORT RAIL BY MECHANICAL CONTRACTOR SHUTOFF VALVE (TYP.) FLEXIBLE CONNECTOR (TYP.) SOLENOID VALVE FURNISHED BY MFR. — INSTALLED BY MECHANICAL FROSTAT KIT SHALL BE PROVIDED WITH UNIT CU -1 5 5 DIFFUSER NECK AS MIN. OF 5 HIGH I STRAIGHT VERTICAL CONY AT DIFFUSER CONNECTION DIFFUSER GAS VENT THRU ROOF PENETRATION CLAY 00 U! s OCT 161563 80 Dote Description Dat8 Comm. No. Drawn: Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS MECHANICAL DETAILS CRY Uf TUKV \'ILA SEP 1 11663 PERMITCENTER Sheet thither M511 CIRNFgh2m Group Architecture Interior 01411 Planning Construction SerAces 201 Main SL 5.E. Suite 325 Minneapolis, MN 55414 Telephone, 612- 379 -3400 Facsimile: 612- 379 -4900 www cut ww ningham.com 7/2/98 CAP0I5 RIFE AIR UNES SEE PLAN FOR CONTINUATION • MAIN AIR REGULATOR • SEPARATOR • COALESCING FILTER • REFRIGERATED AIR DRYER CONCRETE PAD BY MECHANICAL CONTR. 42 ° C NOTES. OPTIONAL RISE BACKUP TO PREVIOUS INVERT ELEVATION 3" FLOOR SINK rnc1%t79 N 1. ALL ITEMS NTH AN ASTERISK ARE PRONGED 85 KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 2. PIPE ALL DRAIN ONES TO FLOOR DRAIN. • MAIN MANIFOLD WITH VALVES BY PASS • ISOLATION PADS • COMPRESSOR HORIZONTAL OR VERTICAL O AIR COMPRESSOR PIPING DETAIL 1 NO SCALE 1. ANY CROSSING OF SHOW PIPING OR AQUARIUM PIPING SHALL BE ACCOMPLISHED BY 040504 LNG THE DISCHARGE UNES. ALL SUCTION UNES SHALL REMAIN FLAT AT A INVERT ELEVATION WHICH ALLOWS THIS. 2. CONTRACTOR HAS THE OPTION OF GOING UNDER OR OVER THE UNE BONG CROSSED. 3 CONTRACTOR CAN HAVE THE OFFSET PIPE RETURN TO THE PREVIOUS INVERT ELEVATON OR CAN RUN AT THE NEW INVERT ELEVATION PROVIDING IT WORKS WITH THE OTHER UNES. SUCTION LINE O SHOW PIPING OFFSET DETAIL 4 NO SCALE 45' 4 SOMAT NOTES 1. MECHANICAL CONTRACTOR SHALL INSTALL ALL VALVES PROVIDED WITH 50MAT.UNIT AND MAKE PIPING CONNECTIONS TO EQUIPMENT AS REQUIRED. 2. PIPE SIZES TO BE IN ACCORDANCE 01TH SOMAT RECOMMENDATIONS. 3. SLURRY AND RETURN WATER PIPING TO BE TYPE L COPPER, SCHEDULE 40 GALVANIZED OR EQUAL (PVC PIPING NOT ACCEPTABLE). 4. SLURRY UNES MUST NOT INCLUDE ANY VALVIN0 EXCEPT THOSE AUTHORIZED BY SOMAT. 5. ALL FITTINGS MUST BE PRESSURE RA1E0 DRAINAGE TYPE (SEE RIGHT) AND KEPT TOA MINIMUM. MAXIMUM ELBOWS ALLOWED 10 PER 100 FEET. USE ELBOWS ONLY TO CHANGE DIRECTION. DO NOT OFFSET AROUND BEAMS, COLUMNS, OR OTHER OBSTRUCTIONS. USE 45 DEGREE Y- BRANCH OR 90 DEGREE LONG TURN T -5 WHERE TWO UNES INTERCONNECT. CONNECTIONS SHOULD BE MADE FROM THE TOP. 7. INSTALL ALL VALVES AND CHECK VALVES HORIZONTALLY. 8. CLEANOUTS REQUIRED IN SLURRY UNES ONLY AND MUST BE INSTALLED AT EVERY 90 DEGREE BEND AND EVERY 60 FEET MAXIMUM IN STRAIGHT PIPE RUNS. USE 45 DEGREE Y- BRANCH AND 90 DEGREE LONG TURN T -Y FOR CLEANOUTS. (ALL CLEANOUTS MUST BE ACCESSIBLE). 9. SOMAT PULPER REQUIRE FLEXIBLE CONNECTORS IN SLURRY AND RETURN UNES ONLY. 10. COMPANION FLANGE, GASKETS AND HARDWARE NOT SUPPLIED AT PIPE LINE TERMINATIONS. 11. KEEP DRAINS ACCESSIBLE TO UNIT. 00 NOT INSTALL DRAINS UNDER SOMAT EQUIPMENT. 12. PIPING MUST BE SUP ORTED AND BRACED INDEPENDENTLY OF SOMAT EQUIPMENT. ALL INTERCONNECTING PIPING'. MUST BE .SUPPORTED SO THAT NO MOVEMENT OCCURS DURING OPERATION. USE UNIONS OR FLANGES FOR FINAL CONNECTIONS 13. NO EXTERNAL STRAIN TO BE EXERTED ON SOMAT EQUIPMENT.. 14. IF 414° AIR LINE IS RUN UNDERGROUND, A LOOP SEAL EXTENDEING 3" ABOVE THE HIGHEST. POINT N THE PULPER MUST BE PROVIDED. 15. ALL PIPING TO BE IN ACCORDANCE WITH STATE AND. LOCAL PLUMBING CODES. 16. (r) = FURNISHED BY SOMAT. TO DRAIN 2 RETURN LINE m DISCHARGE LINE " DIMENSION OF OFFSET (AS REQUIRED) C.0 }T — 4 .F 1 I N —2" `2" SLURRY UNE _l • 1Q CHEMICAL TANK BY OWNER. GREASE EXHAUST DUCT - SEE PLAN FOR SIZE & CONTINUATION GREASE DUCT. PITCH BACK TO KITCHEN HOOD 1/4' PER FOOT. GREASE TIGHT ACCESS DOOR 3/4 DRAIN VALVE WITH HOSE CONNECTION. PROVDE 84114 WATER /GREASE 11085 CAP. 180' SOFTENED HOT WATER (180' SHW) • SHOCK ABSORBER SHUT -OFF VALVE - TYPICAL STRAINER • PRESSURE 6800080 VALVE W11H HIGH PRESSURE BY -PASS UNION - TYPICAL 2" MIN. . • PRODDED BY DO AND INSTALLED BY MECHANICAL CONTRACTOR C J 2 RETURN UNE I I GREASE TROUGH SIDE VIEW O 2 GREASE DUCT TROUGH DETAIL NO SCALE [HOT WATER CONNECT TO DISHWASHER & PROVIDE VACIAAE BREAKERS 111TH STRAINERS CR AR GAP CONNECTION AS REQUIRED 85 LOCAL CODE • CUM6NADON PRESSURE & TEMPERATURE GAUGE TYPICAL COMBINATION PRE591RE & TEMPERATURE REEF VALVE - PIPE TO FLOOR $INK ®` • BOOSTER !EATER O BOOSTER HEATER PIPING DETAIL 5 NO SCALE S C. 4- 2 SLURRY 706E 7 a SOMAT KEY NOTES THROTTUNG VALVE (•). O BACKFLOW PREVENTER w/BUILT -IN STRAINER (•). O SHOCK ARRESTOR (r). O SOLENOID VALVE (•). O CHECK VALVE - FLANGED SWING TYPE. (•) OB FLEXIBLE CONNECTOR - RANGED. (•) O DRAIN VALVE. (r) O B MAKE CONNECTION TO SPREADER PLATE. O MAKE CONNECTION TO FLUSH NOZZLE. RUSH NOZZLE BY SOMAT. 10 PULPER UNIT. (•) EXTRACTOR UNIT. (r) COUPUNG. (•) 1Q ADDITIVE PUMP. (.) 14 MOTORIZED VALVE. (r) 48• AIR UNE TO AIR PUMP IN CONTROL PANEL 20' -0" OF AIR PIPING FURNISHED WITH CONTROL PANEL. 18 CONTROL PANEL. WITH 2D -0" COILED n AIR PIPING. OMAT SYSTEM. DETAIL NO SCALE SOMAT FITTINGS 90' LONG TURN T -Y 90' LONG RADIUS ELBOW 4- FLOOR SINK i W 1. 141800 /912 (COPPER PIPE) 2. STOCKHAM .344 (GALVANIZED PIPE) 1. NIBCO 1607 -LT (COPPER PIPE) 2. STOCKMAN 1306 (GALVANIZED PIPE) 45' Y- BRANCH 1. NIBCO .910 (COPPER PIPE) 2. STOCKHAM /350 (GALVANIZED PIPE) TO CHEMICAL TANK 1 � 2 - J ' PRESSURE PIPE PITCH Y" PER FT. (TIP) 60 1. (r) ALL PIPING & EQUIPMENT SHOWN WITH SOLID LINES OR WITH AN ASTERISK ARE FURNISHED BY (OEI) 114E KITCHEN EQUIPMENT SUPPLIER. 2. REFER TO DOS HOSE REEL DETAIL ON SHEET P4 FOR DIMENSIONS & MOUNTING HEIGHTS. 3. ALL PIPING SHOWN WITH DASHED UNES & THE FITTINGS BY THE MECHANICAL CONTRACTOR. ALL EXPOSED PIPING SHALL BE CHROME PLATED. REEL • VACUUM BREAKER EXPOSED PIPE MEN DE 1,R,L CONSECSON J II ) ESCUTCHEON BY MEQL IN WALL PRESSURE PIPE 100 -2 IDF -1 84400 c�i Y" p • RAU. MOONED WXNG FAUCET O 6 HOSE REEL DETAIL NO SCALE EXPOSED PIPE VPL AIL HOT WATER INLET C00 WATER INET • FAUCET ROTATED IT FOR CURRY • CHECK VALVES INDUCED DRAFT FAN INSTALL PER MANUFACTURERS RECOMMENDATIONS ("DP). REFER TO DETAIL 9/0510 FOR MORE INFORMATION 6 "0 VENT OUTLET (TYP) O WATER HEATER VENT PIPING DETAIL 3 NO SCALE 199,000 BTUH INPUT EACH WATER HEATER 4" HIGH CONCRETE PAD. EXTEND 6 BEYOND WATER HEATERS IN ALL DIRECTIONS Ii•IBI ALL OCT 1816D3 Na. Date Description Date Comm. No Drawn: CAFE Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS Sheet The MECHANICAL DETAILS Sheet Nutter 201 119in SL S.E. Suite 325 Minneapolis, MN 55419 Telephone: 612 - 379 -3400 Facsimile: 612- 379 -4400 Internet: wwwcuninghom cam C , 27 CRV R bf'i ;.l ":ILA PERMIT CENTER M512 Cuninghem Group Architecture Interior Design Planning Construction 5e1ces 7/2/98 CAP115 R0PB Y1-�gB -one UNDERFLOOR SHOW PIPING PLAN 1 1/8" = 1.0' NORTH GENERAL NOTES 1. ALL PIPE STUBS THROUGH FLOOR SHALL BE COORDINATED WITH OLYMPIC POOLS, ICM & ROCKWORK INSTALLERS. EXTEND PIPE TO 24 A.F.F. AND CAP, UNLESS NOTED OTHERWISE. ALL FLOOR PENETRATORS SHALL BE SEALED WATER TIGHT. 2. REFER TO OLYMPIC POOLS DRAWINGS. FOR ADDITIONAL INFORMATION REGARDING SHOW PIPING AND FOR EXACT LOCATION OF STUBS AT WATER FEATURES. ALL PIPING SHALL HAVE LONG RADIUS ELBOWS. 3. REFER TO SHEET 9610 FOR ABOVE FLOOR .SHOW PIPING. 4. COORDINATE ALL UNDERFLOOR SHOW PIPING WITH PIPING ON SHEET 4100. SHOW PIPING SHALL RUN BELOW SANITARY AND STORM DRAIN PIPING. KEY NOTES O 3 AQUARIUM SUPPLY (AS) STUB THROUGH FLOOR AND EXTEND TO 24" A.F.F. AND CAP. USE ICM PROVIDED TEMPLATES FOR PIPE LOCATIONS. SHUT -OFF VALVE AND FINAL CONNECTORS PROVIDED BY ICM. 4" AQUARIUM RETURN (AR) 5TUB THROUGH FLOOR AND EXTEND TO 24" A.F.F. AND CAP. USE ICM PROVIDED TEMPLATES FOR PIPE LOCATIONS. SHUT -OFF VALVE * AD FINAL CONNECTIONS PROVIDED BY ICM. O3 ALL PIPING OFFSETS TO BE DONE WITII DOUBLE 45• ELBOWS. REFER TO DRAWING 4/M512 FOR SHOW PIPING OFFSET DETAIL. O 4" AQUARIUM SUPPLY (A5) & 3" AQUARIUM SUPPLY (AS). COORDINATE STUB -UP LOCATORS NAIR ICM. O 5 2" RAIN CURTAIN SUCTION (RCS) & 2" RAIN CURTAIN DISCHARGE (RCD). REFER TO OLYMPIC POOLS DRAWING 1 /•600 FOR EXACT STUB -UP LOCATIONS. ▪ 6" AQUARIUM RETURN (AR) & 4 AQUARIUM RETURN (AR). COORDINATE STUB -UP LOCATIONS 16111 ICM. • 2° RAIN CURTAIN SUCTION (RCS). REFER TO OLYMPIC POOLS DRAWING 1/W400 FOR CONTINUATION. O B 2 RAIN CURTAIN DISCHARGE (600). REFER TO OLYMPIC POOLS DRAWING 1/W400 FOR CONTINUATION. No. Date D660,80on Dote: Cunbgham Group Architecture Interior Design Planning Canslructian Services 201 Main S1. S.E. Suite 325 Minneapolis, MN 55414 Telephone: 612- 379 -3400 Facsimile 612-379-4400 www.cuningharn.com w nngham.com 7/2/98 Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS Meet NM UNDERFLOOR SHOW PIPING PLAN R„_nrz2 CITY OF 5 UKV0ILA SEP 1 1 1393 Sheet Nullber PERMIT CENTER M600 i J 6 1 i 8 (9 , 10 ' 11 1' SEE OL MPIC POOLS DRAWPIG W600 OR WATER FEATURE - ING P1 IN THIS AREA i _ ` I� ` lid NM _ 1 MOWN - - -, I� III: =- ■ ..- ® o ■I I L r o < " r 1 SEE OLYMPIC ------ FOR POOLS RAWING WATER F ATURE 111•• gm • ' s SEE OLYMPIC OOLS DRA NG "" ' -� _ _ ,.; W600 FOR W TER FEATURE / IN THIS A PUMPS AND PIPE. _ G IN THIS ROO • _- J � ' GORILLA ga VIGNETTE sv— �— a' JF • 2z Op, C7> ev o m Ij G CI �� f —. ' I e ■ �0 r i •i.T s- ■ � I o el e��l�ea� 1' r�.�11�� rj MI II I 1 A (TLA8 MAN VIGNETTE 7 r •. I- I ■ © IOW S -SHAPED V - �`,• ��; 7 \"•-____' - {AQUARIUM .. o �o• l _ 1 �..� J TRACY "H--y.:; TIiCC �x (( t,�, O .. Al O VII ; ) i en ow h 1- II �M \y _ 6 14v I. mast i - •! 11 . 7j I R. g 1 ea 1 CfSIGE EA � 6 �d�'— " m um 1 o ur I \ ■ ( OCULUS pp �� < N RAIN CURTAIN 4 . r is ■ I ; I ° J 1 �w� ' t I`. 1 1 �I ■ 1 @IV I VIGNETTE ‘' { 111 1 CROCOD 6/� CROCODLE POND ._. ¢ �., • ELEPHANT - © I n )OLS DRAWOJG TER FEATURE THIS AREA I 0 ow co"' a 0 0 W es' 1 � IL'aI E ©M .1 VIGNETTE © <' /��' ■ 0 ARCHED AQUARIUM '.1%‘''''''''-------SEE � , 1 " "' I ` :'A, �` �; ® I�A 1 a ■k�II,M A ffil `_^ A l L ° d .. ~ 1 � o E 'i J L / ( I ■ RAIN CURTAIN a 1WIM - i 1 • - r , /� ' S-SHAPED ■� AQUARIUM /�� wrw - , _ til La � l �I�. f lititel.aulllai r�.Ii� V M r .� • \ \ \ Y1-�gB -one UNDERFLOOR SHOW PIPING PLAN 1 1/8" = 1.0' NORTH GENERAL NOTES 1. ALL PIPE STUBS THROUGH FLOOR SHALL BE COORDINATED WITH OLYMPIC POOLS, ICM & ROCKWORK INSTALLERS. EXTEND PIPE TO 24 A.F.F. AND CAP, UNLESS NOTED OTHERWISE. ALL FLOOR PENETRATORS SHALL BE SEALED WATER TIGHT. 2. REFER TO OLYMPIC POOLS DRAWINGS. FOR ADDITIONAL INFORMATION REGARDING SHOW PIPING AND FOR EXACT LOCATION OF STUBS AT WATER FEATURES. ALL PIPING SHALL HAVE LONG RADIUS ELBOWS. 3. REFER TO SHEET 9610 FOR ABOVE FLOOR .SHOW PIPING. 4. COORDINATE ALL UNDERFLOOR SHOW PIPING WITH PIPING ON SHEET 4100. SHOW PIPING SHALL RUN BELOW SANITARY AND STORM DRAIN PIPING. KEY NOTES O 3 AQUARIUM SUPPLY (AS) STUB THROUGH FLOOR AND EXTEND TO 24" A.F.F. AND CAP. USE ICM PROVIDED TEMPLATES FOR PIPE LOCATIONS. SHUT -OFF VALVE AND FINAL CONNECTORS PROVIDED BY ICM. 4" AQUARIUM RETURN (AR) 5TUB THROUGH FLOOR AND EXTEND TO 24" A.F.F. AND CAP. USE ICM PROVIDED TEMPLATES FOR PIPE LOCATIONS. SHUT -OFF VALVE * AD FINAL CONNECTIONS PROVIDED BY ICM. O3 ALL PIPING OFFSETS TO BE DONE WITII DOUBLE 45• ELBOWS. REFER TO DRAWING 4/M512 FOR SHOW PIPING OFFSET DETAIL. O 4" AQUARIUM SUPPLY (A5) & 3" AQUARIUM SUPPLY (AS). COORDINATE STUB -UP LOCATORS NAIR ICM. O 5 2" RAIN CURTAIN SUCTION (RCS) & 2" RAIN CURTAIN DISCHARGE (RCD). REFER TO OLYMPIC POOLS DRAWING 1 /•600 FOR EXACT STUB -UP LOCATIONS. ▪ 6" AQUARIUM RETURN (AR) & 4 AQUARIUM RETURN (AR). COORDINATE STUB -UP LOCATIONS 16111 ICM. • 2° RAIN CURTAIN SUCTION (RCS). REFER TO OLYMPIC POOLS DRAWING 1/W400 FOR CONTINUATION. O B 2 RAIN CURTAIN DISCHARGE (600). REFER TO OLYMPIC POOLS DRAWING 1/W400 FOR CONTINUATION. No. Date D660,80on Dote: Cunbgham Group Architecture Interior Design Planning Canslructian Services 201 Main S1. S.E. Suite 325 Minneapolis, MN 55414 Telephone: 612- 379 -3400 Facsimile 612-379-4400 www.cuningharn.com w nngham.com 7/2/98 Southcenter Mall Tukwila, WA CONSTRUCTION DOCUMENTS Meet NM UNDERFLOOR SHOW PIPING PLAN R„_nrz2 CITY OF 5 UKV0ILA SEP 1 1 1393 Sheet Nullber PERMIT CENTER M600 GENERAL NOTES 1. ALL PIPE STUBS THROUGH FLOOR SHALL BE COORDINATED WITH SYSTEM VENDORS & ROCKWORK INSTALLERS. EXTEND TO 24" A.F.F. AND BE CAPPED UNLESS NOTED OTHERWISE. ALL FLOOR PENETRATIONS SHALL BE SEALED WATER TIGHT. 2. SEE OLYMPIC POOLS DRAWINGS, FOR ADDITIONAL INFORMATION REGARDING SHOW PIPING AND EXACT LOCATION OF STUBS AT WATER FEATURES. ALL PIPING SHALL HAVE LONG RADIUS ELBOWS. 3. ANIMA1100 EQUIPMENT AND FINAL CONNECTIONS BY KX INTERNATIONAL 4. SEE TO SHEET 6600 FOR UNDERFLOOR SHOW PIPING. 5. COORDINATE ALL ABOVE FLOOR SHOW PIPING WITH SHEET 8110 PIPING. 6. PROVIDE RUBBER INSULATION ON ALL COPPER WATER & AIR LINES IN TREES & WALLS. 7. NOT ALL PIPING RUNNING IN VIGNETTE BASES ARE SHOWN FOR CLARITY. SEE KEY NOTES FOR EXPLAINATION OF WORK TO BE DONE. KEY NOTES 44" ANIMATION PIPES (A61, A@5. & A#3). CONNECTIONS TO MAIN MANIFOLD BY 1 MECHANICAL CONTRACTOR. SEE 1/6512 FOR AIR COMPRESSOR DETAIL ANIMATION 1 EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. INSTALL ACCUMULATOR TANK ON THE FLOOR AND INSTALL AIR MANIFOLD ON PLYWOOD BACKING AT 12" A.F.F. FOR THE ANIMATION SYSTEM BELOW THE PLATFORM AND 0 WITHIN 12" OF THE ACCESS DOOR. PLYWOOD BY GENERAL CONTRACTOR. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 15" ANIMATION PIPE (094) TO "SWINGING BABY GORILLA." PROVIDE A 46" FEMALE NPT 0 FITTING AND TERMINATE AT 6" ABOVE THE GREENERY CEILING. FINAL CONNECTIONS BY KX INTERNATIONAL. 16" ANIMATION PIPE (A95). CONNECT TO ACCUMULATOR TANK ABOVE GREENERY 10 CEILING. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 1/4" ANIMATION PIPE (AO) FROM ACCUMULATOR TANK, DOWN IN TREE AND CONNECT NY TO MANIFOLD. MOUNT MANIFOLD NEXT TO ACCESS DOOR IN TREE. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 0 (3) Y4" ANIMATION PIPE (A#6. A #7. & 098) DOWN IN TREE. PROVIDE 46" FEMALE FITTINGS AND TERMINATE 12" ABOVE MANIFOLD. FINAL CONNECTIONS TO ANIMAION EQUIPMENT BY KX INTERNATIONAL. 2) 1/2" ANIMATION PIPE (A96 & A$7) DOWN IN TREE AND RUN BELOW PLATFORM TO 0 1 CROCODILE POND." PROVIDE 46" FEMALE NPT FITTINGS AND TERMINATE WITHIN 12" OF THE ACCESS 000R AT 12" A.F.F. ANIMATION EQUIPMENT AND FINAL CONNECTIONS BY KX INTERNATIONAL. 15" ANIMATION PIPE (A98) TO "SNAKE VIGNETTE." PROVIDE A 46" FEMALE NPT 14 FITTING AND TERMINATE AT 8" ABOVE THE GREENERY CEILING. FINAL CONNECTIONS BY KX INTERNATIONAL. 11" ANIMATION PIPE (Ay9) DOWN IN WALL AND RUN BELOW PLATFORM TO "GORILLA ". - 15 PROW10E 48" FEMALE NPT MTTNOS AND TERMINATE WITHIN 12" OF THE ACCESS DOOR AT 12" A.F.F. ANIMATION EQUIPMENT AND FINAL CONNECTIONS BY KX INTERNATIONAL. N0. Date Desup00n Date Cuningham Group Architecture Interior Design Planning Construction Services 201 Main 5t. 5.E. Suite 325 Minneapolis. MN 55414 Telephone: 612-379-3409 Facsimile: 612-379-4400 www.ouninghom.com HANG ACCUMULATOR TANK FOR THE ANIMATION SYSTEM A MAXIMUM OF 10" ABOVE 0 GREENERY CEILING OVER TREE TRUNK. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 11" ANIMATION PIPE (A#1) DOWN IN WALL AND RUN BELOW PLATFORM TO 0 ACCUMULATOR TANK ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. Dra.e ART 0 16" ANIMATION PIPE (A#2), NOT ' USED. O 1/4" ANIMATION PIPE (A#2), NOT USED. 55" ANIMATION PIPE (A#3) DOWN IN WALL AND RUN BELOW PLATFORM TO 0 ACCUMULATOR TANK. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 16" ANIMATION PIPE (094 & 0/6) DOWN IN WALL AND RUN BELOW PLATFORM TO 12" 0 FROM MANIFOLD. PROVDE 48 FEMALE NPT FITTING. FINAL CONNECTIONS BY Reg R S :, q !. ? 292 -01 KX INTERNATIONAL Southcenter Mall Tukwila, WA ABOVE FLOOR SHOW PIPING PLAN Sheet Number T' CITY OF T'UI.'tVILA seta 1 9 95;,23 PERMITCENTER M610 7/ CAP115 CONSTRUCTION DOCUMENTS 6 i a) ( 9 ) I10 1 11 12 NO PIPING INSTALLED I N OR ABOVE THIS AREA EQUIPMENT IN THI AREA FURNISHED BY SYSTEM VEND R AND INSTALLED BY MECHANICAL CONTRACTOR ' r. '" Et , M U Y■ � �I liV I i I m I „ )p J ` � J �J el® i Ij 1 I _ 'T. NO PIPING INSTAL. ED s I, IN OR ABOVE THI - AREA P, r im - \ GORILLA • � VIGNETTE 0 I� • j�� 1 Q II � � ..,@ r"'-' , � yr I II � J NI v pi It �' 7 B ■ 1 ) 7.1 TT—E -; . —. - �� - 1 il l li �■L�i III, I i ill 1. �■ A SS ,rfc • 0 — TRACY J ) , 2 �� u l ATLA8 VIGNETTE MAN S— SHAPED AQUARIUM i ■l VII' Ilf ■ p I \R IEI� I dell PAW I , OCULUS RAIN CURTAIN �, ii y "� � ll VIGNETTE \JI�� 11 �=� 1e � II E: ;/ N yule � watimwoll • 1 _ rt_ i�a■ �� ti .i O ® ELEPHANT VIGNETTE - ti - t" v %III � ARCHED AQUARIUM .: ■■ ,I � I N 7 il ��� �" a OEM '•A . y� , V' w' I, ` S-SHAPED AAA in ;1 eci=s0 R CURTAIN \` U I It I • - L I • I j���.4���ff AQUARIUM Q 1 I '°ww E * . , p r � m 1 s_ I ` /. r / I al � _ _ fi 4 - _ MI El In Irn 1 __ I II \ \ 1 I 1 6 1S - 0 1 ,---:-, AR(VF FL OOR SHOW PIPING PI AM GENERAL NOTES 1. ALL PIPE STUBS THROUGH FLOOR SHALL BE COORDINATED WITH SYSTEM VENDORS & ROCKWORK INSTALLERS. EXTEND TO 24" A.F.F. AND BE CAPPED UNLESS NOTED OTHERWISE. ALL FLOOR PENETRATIONS SHALL BE SEALED WATER TIGHT. 2. SEE OLYMPIC POOLS DRAWINGS, FOR ADDITIONAL INFORMATION REGARDING SHOW PIPING AND EXACT LOCATION OF STUBS AT WATER FEATURES. ALL PIPING SHALL HAVE LONG RADIUS ELBOWS. 3. ANIMA1100 EQUIPMENT AND FINAL CONNECTIONS BY KX INTERNATIONAL 4. SEE TO SHEET 6600 FOR UNDERFLOOR SHOW PIPING. 5. COORDINATE ALL ABOVE FLOOR SHOW PIPING WITH SHEET 8110 PIPING. 6. PROVIDE RUBBER INSULATION ON ALL COPPER WATER & AIR LINES IN TREES & WALLS. 7. NOT ALL PIPING RUNNING IN VIGNETTE BASES ARE SHOWN FOR CLARITY. SEE KEY NOTES FOR EXPLAINATION OF WORK TO BE DONE. KEY NOTES 44" ANIMATION PIPES (A61, A@5. & A#3). CONNECTIONS TO MAIN MANIFOLD BY 1 MECHANICAL CONTRACTOR. SEE 1/6512 FOR AIR COMPRESSOR DETAIL ANIMATION 1 EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. INSTALL ACCUMULATOR TANK ON THE FLOOR AND INSTALL AIR MANIFOLD ON PLYWOOD BACKING AT 12" A.F.F. FOR THE ANIMATION SYSTEM BELOW THE PLATFORM AND 0 WITHIN 12" OF THE ACCESS DOOR. PLYWOOD BY GENERAL CONTRACTOR. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 15" ANIMATION PIPE (094) TO "SWINGING BABY GORILLA." PROVIDE A 46" FEMALE NPT 0 FITTING AND TERMINATE AT 6" ABOVE THE GREENERY CEILING. FINAL CONNECTIONS BY KX INTERNATIONAL. 16" ANIMATION PIPE (A95). CONNECT TO ACCUMULATOR TANK ABOVE GREENERY 10 CEILING. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 1/4" ANIMATION PIPE (AO) FROM ACCUMULATOR TANK, DOWN IN TREE AND CONNECT NY TO MANIFOLD. MOUNT MANIFOLD NEXT TO ACCESS DOOR IN TREE. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 0 (3) Y4" ANIMATION PIPE (A#6. A #7. & 098) DOWN IN TREE. PROVIDE 46" FEMALE FITTINGS AND TERMINATE 12" ABOVE MANIFOLD. FINAL CONNECTIONS TO ANIMAION EQUIPMENT BY KX INTERNATIONAL. 2) 1/2" ANIMATION PIPE (A96 & A$7) DOWN IN TREE AND RUN BELOW PLATFORM TO 0 1 CROCODILE POND." PROVIDE 46" FEMALE NPT FITTINGS AND TERMINATE WITHIN 12" OF THE ACCESS 000R AT 12" A.F.F. ANIMATION EQUIPMENT AND FINAL CONNECTIONS BY KX INTERNATIONAL. 15" ANIMATION PIPE (A98) TO "SNAKE VIGNETTE." PROVIDE A 46" FEMALE NPT 14 FITTING AND TERMINATE AT 8" ABOVE THE GREENERY CEILING. FINAL CONNECTIONS BY KX INTERNATIONAL. 11" ANIMATION PIPE (Ay9) DOWN IN WALL AND RUN BELOW PLATFORM TO "GORILLA ". - 15 PROW10E 48" FEMALE NPT MTTNOS AND TERMINATE WITHIN 12" OF THE ACCESS DOOR AT 12" A.F.F. ANIMATION EQUIPMENT AND FINAL CONNECTIONS BY KX INTERNATIONAL. N0. Date Desup00n Date Cuningham Group Architecture Interior Design Planning Construction Services 201 Main 5t. 5.E. Suite 325 Minneapolis. MN 55414 Telephone: 612-379-3409 Facsimile: 612-379-4400 www.ouninghom.com HANG ACCUMULATOR TANK FOR THE ANIMATION SYSTEM A MAXIMUM OF 10" ABOVE 0 GREENERY CEILING OVER TREE TRUNK. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 11" ANIMATION PIPE (A#1) DOWN IN WALL AND RUN BELOW PLATFORM TO 0 ACCUMULATOR TANK ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. Dra.e ART 0 16" ANIMATION PIPE (A#2), NOT ' USED. O 1/4" ANIMATION PIPE (A#2), NOT USED. 55" ANIMATION PIPE (A#3) DOWN IN WALL AND RUN BELOW PLATFORM TO 0 ACCUMULATOR TANK. ANIMATION EQUIPMENT FURNISHED BY KX INTERNATIONAL AND INSTALLED BY MECHANICAL CONTRACTOR. 16" ANIMATION PIPE (094 & 0/6) DOWN IN WALL AND RUN BELOW PLATFORM TO 12" 0 FROM MANIFOLD. PROVDE 48 FEMALE NPT FITTING. FINAL CONNECTIONS BY Reg R S :, q !. ? 292 -01 KX INTERNATIONAL Southcenter Mall Tukwila, WA ABOVE FLOOR SHOW PIPING PLAN Sheet Number T' CITY OF T'UI.'tVILA seta 1 9 95;,23 PERMITCENTER M610 7/ CAP115 CONSTRUCTION DOCUMENTS