HomeMy WebLinkAboutPermit M98-0182 - SOUTHCENTER MALL - GENE JUAREZ SALON AND SPA(one jupcire SaA or\ Mqg SZ City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M98 -0182 Type: B -MECH Category: NRES Address: 1070 SOUTHCENTER MALL Location: Parcel #: 262304 -9004 Contractor License No: EMERAAI055BL MECHANICAL PERMIT TENANT GENE JUAREZ SALON AND SPA 1070 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTRACTOR EMERALD AIRE INC. Phone: 206 872 -5665 22043 68TH AVENUE SOUTH, KENT, WA 98032 CONTACT SHANNON BUCKINGHAM Phone: 425 -872 -5665 22043 68 AV S, KENT WA 98032 ******************************************** * * * * * * * * * * * * * * * ** * * **** ** * * * * ** Permit Description: INSTALL SIX (6) HVAC ROOF -TOP UNITS, FOUR (4) EXHAUST FANS, THREE (3) DUCT HEATERS AND ASSOCIATED DUCT WORK. UMC Edition: 1997 * * * ** ** * * * * * * * * * ** tilt********** *tk * * * * * * * ** * * * * * * * * * * * * * * *** ** *fit* *fit * ** * * * * ** Permit nter Authorized Print Nam ignature t Valuation 150,000.00 Total Permit Fee: Date (206) 431 -3670 Status: ISSUED Issued: 10/29/1998 Expires: 04/27/1999 162.63 I hereby . certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied 'with, ..whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construe ion or ii,,t�'e performa e of .work. I am authorized to sign for and obtain th s bui `ing per Signature : - '- 6f,/V4 !• � , 7 _ Date: 1 Title: This permit shall become nulland void if .t.h.e.,work is not commenced within 180 days from the date of issuance, or if'the work is suspended or abandoned for a period of 180 days from the last inspection. Pct Name/T: 1nt: J ► .t . A _. . * L Value of Construction: a .0 . • .*" _ Site ddress: 1 i �., C' y tate /Zip: - : . ,_ . if, . ( / / M a l t 1 .ti .'. Tax Parc:l Numb:r: .,. b -- A2 Property Owner: 0 Phone: Street Address: City State /Zip: Fax #: Phone: - 7,,S5 07 SC,0 C ct P w 1 1 (!, �1; r / / n c � i � V Ylrn X11 1, h 'hair) Street Address: • tate /Zip: Fax #: Co tractor: r T.�-x Pho ES 3 R 7Z (5 Street Address: City t to /Zip: .o ii.5 tom Ada -- e.;* f 7S63 Z, - Fax #: s.3 70S'7 9 7 Ajtect: t - (.K iCii /' /,k( }rl Phone: z 4 - 6 y - ts/ 7'9 .4 Street Address: .-- F ,, City State /Zip: // i' /t/, 35 (S ; i S/ J 5 s ' 3( �tT7i 9s x-5 Fax #• rJ�l9 En eer �Z // i'ftl r"► <' Phone: Z�4 -- 2 . )(4 ' 906/ 6 Y Street Add s: G � Ciitt; State /Zip: /z)5 �'U; g :St �c,<JfT.r / 076)3 Fax #: 70CD-76& `J�r MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done: r assoe., Will there be storage of flammable /combustible hazardous material in the building? / ❑ yes ❑ no Attach list of materials and storage location on se arate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Above Ground Tanks DI Antennas /Satellite Dishes ❑ Demolition ❑ Fence ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting Bulkhead /Docks ' Commercial Reroof ❑ echanical ❑ Manufactured Housing - Replacement only Temporary Pedestrian Protection /Exit Systems MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF 1 Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping El Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp it ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk in Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft grading /clearing ❑ Sanitary Side Sewer #f: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: City /State /Zip: Phone: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. F -5 ;17 ation acc t d: 1 V1 M MISCPMT.DOC 7/11/96 Date application expires: atlon taken by: (initials) • BUILDING OW R OR AUTHORIZED AGENT: Date: C7A El Signatu Submit checklist No: M - 1 0 ) Commercial Tenant Improvement Permit Print name: Bulkhead /Dock Submit checklist No: M -10 ri P one: F -x #• Add 7 L/ ( /�, , h 't' J 0 Ci) /State Zip c� /� O,!► ', � 0la c iero ? , 0 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly Upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist No: M -9 El Antennas /Satellite Dishes Submit checklist No: M - 1 0 Awnings /Canopies - No signage Commercial Tenant Improvement Permit Bulkhead /Dock Submit checklist No: M -10 ri Commercial Reroof Submit checklist No: M -6 Demolition Submit checklist No: M -3, M -3a 0 Fences - Over 6 feet in Height Submit checklist No: M -9 0 Land Altering /Grading /Preloads Submit checklist No: M - 2 Loading Docks s' Commercial Tenant Improvement Permit. Submit checklist No: H -17 Mechanical (Residential & Commercial) Submit checklist No. M -8, Residential only - H -6, H -16 Miscellaneous Public Works Permits Submit checklist No: H - 9 O Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M - 5 0 Moving Oversized Load /Hauling Submit checklist No: M - 5 0 Parking Lots Submit checklist No: M -4 O Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist . No: M -6 0 Retaining Walls - Over 4 feet in height Submit checklist No: M -1 e Temporary Facilities Submit checklist No: M -7 0 Temporary Pedestrian Protection/Exit Systems Submit checklist No: M - 4 0 Tree Cutting Submit checklist No: M -2 ALL MISC._,LANL t7 ' P IT APPLICATIONS MUST BE SUB TED WITH THE FOLLOWING: *e ➢ ALL DRAWINGS SUALL BE AT A LEGIBLE'SCALE AND NEATLY DRAWN ➢ BUILDING SIi'E PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) 2V Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,or, contactor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 P j ct Name/T: :n : Description of work to be don . agsc. 4 Sr. /1 .5 s( ii , r v 0 ,/ 1 "V P5thic a „ f . � diteil er—i i dack Value of Construction: Site ' ddress: 1 :. c- —.A. 1a. I / i .11l I Ai C' y tate /Zip: „ Tax Parq:I Numb - r: _, G ` 69 Property Owner: 1/ Phone: Phone: Street Address: City State /Zip: Fax 1/: City /State /Zip: j cki'n Phone: . 7, � E 7z &o( ct Re V - nrnr (5h6 nnon tt.c�1� Street Address: 1 ate %p: 2T Li.') /n5 S fie--, [)fit •c :s Fax #: 2<`� 2, 1 ?,,c 4 "7 Co tractor: r SP �--i . Tic City t to /Zip: 7803 z Ph s3 2 S&' E. ' Fax #: rS3 70 S'7 9' 7 Street Address: o ii,s 0 A s )0 Ar tact: �"lx//cix 14' J ? /,k(4hJ Phone: 7 7i, - (p, 3 L) - 0 Street Address: ..- ��, // _ Ai- 2 (5 c S JO S" 3e..z. City State /Zip: - 0. 9//e.:5 Fax #; ,\V19' Enuie�er: y in . i r.n , n-r Phone: Z&0 — 2)(/, ' 90(0 Street Add r s: r /f1 k , . - SR a i re City State /Zip: 87 C) Fax #: Z(l - 7660 "7 MISCELLANEOUS PERMIT REVIEW AND APPROVAL' REQUESTED: (TO BE FILLED OUT BY APPLICANT) , Description of work to be don . agsc. 4 Sr. /1 .5 s( ii , r v 0 ,/ 1 "V P5thic a „ f . � diteil er—i i dack Will there be storage of flammable /combustible hazardous material Attach list of materials and storraa a location on se arate 8 1/2 X in the building? in yes in no 11 a er indicating quantities & Material Safety Data Sheets Bulkhead /Docks ❑ Commercial Reroof echanical El Manufactured Housing - Replacement only Temporary Pedestrian Protection /Exit Systems 7 Above Ground Tanks Ll Antennas /Satellite Dishes ❑ Demolition El Fence El Parking Lots in Retaining Walls El Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping El Flood Control Zone El Landscape Irrigation El Storm Drainage El Water Meter /Exempt # in Water Meter /Permanent it El Water Meter Temp it El Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s)* El Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft grading /clearing in Sanitary Side Sewer #: El Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: in Moving Oversized Load /Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: CITY OF Tr'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Da atlon acc MISCPMT'.DOC 7/11/96 Data application expires: Phone: City /State /Zip: allow taken by: (Initials) ./■•• CITY OF TUKWILA I .,;„4 "g," '- t Address: 1070 SOUTHCENTER MALL Permit No: M98-0132 .Sulte: Tenant: GENE .1UAREZ SALON AND SPA Status: ISSUED,' Type: 841ECH . Applied: 09/23/1998 Parcel #: 262304-9004 . Issued: 10/29/1998 . ***4/*:********:A***A****A.********************************k****** ,Permi!t ConditiOns:, 1 . No changes w i l l be made to the plans unl es's approved by the Arch i tect: or :Engineer and tha.,,,,T4w4,1.a_Building DiVis ion. . • 2. All permits, inspection04001C:4pd4PU plans shall he available at the job'7 to the" any con- •- ' s tr u c t ion. ' T h es:edo c m en ts .are to be ma i ntalitd! and a v a i a b l e e until f inaN:Ins Rao, tjon `:a pp r oal is granted. 3 . A 1 1 con s truCt,)On to .,b be '.done '4,0' 6 rma n Ce'Wit h iioVe d plans and d i reReilts the go form Bu 1'1 dlrig,Code-:=.4957: Ed i tiloieVas;!:;-'"amended,•':% Uniform I'ilei a ni'Cal „,,Code. , and Wash7,1-rigto'*. State Energy Code (1997 E d i t i o n ) ,:, `':.:. ''' „ 7:',1:;•:!,; . - 4 . El ec M'f•i41 i ii'elrim1 ts s hall he ' . O be &I:60 through ;':, t h e:s„.Wa , 0.1 6 6:t'p. 6 .s t a t e ,!)Ci,Tir . 1 i on of Labor iaiid ,IIndus and al l' laclir ipa t work1011,be inspected:-,byY•that agency (248-6630 ,,,,•''' 5. P1 u mbln g perm i t S s ha 1,11: h obtained t h r ou a h the Sea t t nCi,i'A County Departme of ";Public tea th Plumbing ' will bev,% i n sp,e t ad , by t hat a g 6 - 6 6 St iiO Lid i 6 g gas pipi 0; . ,A .. : •„;;; i „,,,!.. '0,k, . , .... t I ■ t : ,, , ( (2964722$ ::. •.,,'::--,,, :? % ..r 6. MANUEACTURERSINSTALLATIONJINSTROTIONS,REQUIRED FORTHEPUILDING --INSPEcTORSV;REVIEW.i, L-',;;' :..,! 7. Val Id i ty Of Permit.. t...' The.:,fiS .‘.. of '; nil i t or approval ic! ' ...,, , ,, , , „, , , _.: 13 1 # v ( „ ; p• f ., el - f , ,i cii t_i,ons'i and , u tatyons s qa 11 not D e , con - 10. s ttriOd to be , a permit for,. 'or an 'a p•pfo vae of , any vSo l ti of k of i Slons thaAb01 Cade or : of ay .) :, ik.''''' • other \ o itgl. n a n c. of the ') u r i s d i ctUneN6 Pe riii t p riSOAttilvi ti; ' g iv eqa t horp'ty :; to violate or cancel ;t1i"•e:.,p f on s'f: Of this S ' code i:ISba 1i) yhe valid. i I f \‘ ,, ,,... , .1 ,, . .. i ,., i is , - ' ' ,.. ::',',' : ,:,:-'• , : :. Z.r24 • , L4 0.■ 1 ,■ t / ?; A n '''' ti \ j i„.„„, DEPARTMENTS: Bui Division Z Pub is Works TUES /THURS ROUTING: \PR•ROUTE.DOC 6/98 PL RE SLIP ACTIVITY NUMBER: M98-0182 DATE: 2 -3 -99 PROJECT NAME: GENE JUAREZ SALON Original Plan Submittal Response to Correction Letter # XX Revision # 1 After Permit Is Issued Response to Incomplete Letter Fire Prevention Structural L , Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) Approved ❑ Approved with Conditions ❑ Planning Division ❑ Permit Coordinator DUE DATE: 2 - - 99 DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ❑ Incomplete Comments. Not Applicable Please Route No Review Required ❑ REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 3 - - 99 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE. CORRECTION DETERMINATION: DUE DATE. Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: M l CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL Mg - 0182- DATE: 1- Z - PLAN CHECK/PERMIT NUMBER: PROJECT NAME: & e , t/ -- / = S/ PROJECT ADDRESS: 1 070 -C"'oUTCt tf1 -' _- /144 -- CONTACT PERSON: f x 0 I.c)I -('O (g 20 24-3— 7 A - e" 0AL zoo — 2 9Sg0 REVISION SUMMARY: 4 CCv1..4- T1C»1tLS Re-? (LS TX-r /c.TLi9 SHEET NUMBER(S) ncouVCD "Cloud" or highlight all areas of revisions and date revisions. CITY OF TUKWILA FEB - 3 1999 PERMIT CENTER SUBMITTED TO: 9OL6Z. REVISION N0,1 a,a" PC4%0 ecorci Con PLAN REVIEW/ROUTING 31.11 ACTIVITY NUMBER: PROJECT NAME: GENE JUAREZ SALON AND SPA XX Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: B ing Division g e.. 10-z:71 Public Works / DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete Incomplete LI Comments' TUES/THURS ROUTING: Routed by Staff El (if routed by staff, make copy to master file and enter into Sierra) DATE: 10/ REVIEWERS INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved REVIEWERS INITIALS. Approved LI \PR-ROUTE.DOC 6/911 Please Route [r No further Review Required El Approved with Conditions CORRECTION DETERMINATION: N98 DATE: 9 NiD Fir ti Prev e tn u tio i n Structure DATE: Planning Division Permit Coordinator DUE DATE: 9-24-98 Not Applicable El DUE DATE: Not Approved (attach comments) 27 cm3 r DUE DATE: Approved with Conditions Not Approved (attach comments) El REVIEWERS INITIALS: DATE: k � •+• rt*I chle*: 1**A:F*:4*%1•hk9t ******#:llk7 *** Jl•• kh* **khnFA***:l•hh:lr4**** *•AA* A*** CITY OF TU(.WILA WA TRANSMIT. *:r*:1 k4 * ******** 4 **)i.kA••k*** * ***h*A **k*4 h.t•4*/e ***4 *'Jr4***h *:t4*4,* *1 **4' TRANSMIT Number: 89700657 Amouht: 162.63.10/29/96 14 :07 Payment Method: 1043. Notation: EMERALD AIRE • Init :. TICF: Permit No: M98- -0182 Type: II• -MECH MECHANICAL. PERMIT Parcel No: 262304 -9004 Site . Address: 1070 30U4HCEtdTER MALL Total Fees: This Payment 162.63 Total ALL Pmts: 4** a* A***** h• k'* kA * * * * * * * * * * *4 * * * * * * *•A* * * *•A , 1 *• * * ** ** * *k* *k *;1 * * ** Oesci'ipti,on PLAN CHECK - 3'1ONREfi MECHANICAL ° NONIZES Account Code 000/345 >830 000/3 ' 162.63 400, Amount 32.53 100.10 �"1, Tr-0 I P r - . 1 -• r.1 ;1 n Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM City of Tukwila Fire Department Project Name 4,fer N / pig " Address / v • ' /c ,4114- // TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM I Retain current inspection schedule C 4 Needs shift inspection Approved without correction notice V Approved with correction notice issued Rev. 2/19/98 C John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. / ? -- - 0 /g Suite # Date *77 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575.4439 COMMENTS: M f h ‘— e 4 <00- /6 e/-e• ,oe .7iPee,t&-4 7 /1-4./e.- pets)-Ara Special instructions: P 72:,-,e2 - ieg-ve5/o41 Phone: g 6 , atv '9 '9-gee_ eregy,-14,we Pt: itl.&Z.- Type of.spectioy: Address: /070 — 5 ez/Ke/e/stoef,t. Date called: Special instructions: Date n Reque ter: Phone: • . . • "77 • INSPECTION REC( D Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 El Approved per applicable codes. Dap: P90 -efaf PERMIT NO. (206)431-3670 Actions required prior to approval. Inspecto AteteZi 0 $47.01 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Ty pgo�f,�n ection : (l alled: ti -- :5MQit-e.- sr" Address: AAd 1 — sC.• M AI--- ate c Date Special instructions: y-.1 S n t Date wanted: a.m. p.m. 2- t■Aw `t .sr" ,& - fly , A. ,•', d ." Paje t: .--.- t � ^ r 'I --G 6 +' Ty pgo�f,�n ection : (l alled: Address: AAd 1 — sC.• M AI--- ate c Date Special instructions: y-.1 S n t Date wanted: a.m. p.m. Requester: Phone: Inspect I I ' INSPECTION REC() i R etain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 Approved per applicable codes. U Corrections required prior to approval. 0 $47.00 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: + .. Nikq PERMIT NO. Date 2 � (206)431 -3670 Project: ;_.r.', "" A iki i ( G. r e 2 — Type Inspection: 0 (1< P r ss: S re --fie ( l Dat called:.. 'II l (ii S ecial instruction;, • Date wa ted; / es e `Z Phone COMMENTS: ` ee!— -' - i --, "�� is z. f..3''`- ,.v,-.s -t T ���7_ -� .s . i i '(e 40./,i , ) /7i /.?i'f,2 k1(i -1. - ' .' / ',4 .07-7 d ri o ff ' / /II ! s- p t • e.e.( 6",!f.- tx;e_ ti / l r� _. S • Ins r ector: Date: , " " ' ,INSPECTION RE ra(s Retain a copy with permit INSPECTION NO. CITY‘OF TUKWILA BUILDING, DIVISION 6300' Southcenter Blvd, #100, Tukwila, WA 98188 Approvedtiper applicable codes. Receipt No: , Date: /A q X - - i ` l K2_ PERMIT NO. (206)431 -3670 Corrections required prior to approval. L $47.00 REINSP(rCTJONfEEREQUIRED. Prior to inspectiori, fqe must be paid ;. at 6300 Southeenter Blvd.,'Sitite 100. Call to schedule reinspection, Proj ?ct: '"'1 Type of inspectid`n _ Address: Date calla.. Special instrq.: • s: ..r / J- � Date wanted a. II Jam.. Requester: "''� Phone No.: A Approved per applicable codes. INSPECTION RE ' D Retain a copy with`. mit INSPECTION NO. CITY OF6TUKWILA BUILDING DIVISION PERMIT N 6300 Southcenter Blvd., #100; Tukwila, WA 98188 (206) 431 3670 Corrections required prior to approval. Inspector/ / 144 • Date: $42.0 REINSPECTIO FEE REQUIRED: \. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Proje6 oct Type of Inspe i n: ve ( LaFe Address) Uyo s ,coirm il/v/ 4t t Date called: t ! � Special instructions: Date wanted: / / � Requester: f VI61 h Phone: - d - 53 `5 )- 5,' INSPECTION NO. INSPECTION REC Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila ,,WA 98188 El Approved per applice'le codes. !Igor-01v_ PERMIT NO. (206)431 -3670 COMMENTS: C Crr/ C <a / ~ 1' 7 z'' /�.4./ '7/7, a 6 rik- - 1 ce r eti Corrections required prior to approval. •••-• / $47.00 REINSPECTIO TE REQUIRED. Prior to inspecti n, fee must be paid at 6300 Southcenter Blvd., Site 100. Call to schedule reinspection. Date: Receipt No: Project: Z. fa , 1 11 �.. Ad res 1 � D' Type of ins.ectio s Date called: : -...A.22.14 '_ lZ —I b Special instructions: Date wanted: 2_0'1,5 Requester: Q,{� Phone No — 010 .+5MW174 :UC . r 't" .. TP- ,wl�,, ".£:.; 7 '`-'r' . '. F 'r4' {PT'., "-` ? " 1 " PPI a 5 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 9818 {J Approved per applicable codes. Receipt No.: INSPECTION RE r. ' - D Retain a copy with mit I PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: ' 7/9'C---- / $42.00 - INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: . COMMENTS: 6 Pi€ es 7 _A4' i i C3 72‘. � /,- Cr'S,_ Type inspection: /ktr�7 J Gr f< f row /-c) P g ( U 6 -7-s L. i Al Ad ress: , 5A/c- / 5 -tt',6/-2a--0 1 A /,C. , /e/. -1 3 Plie,7 c rIA. 5/, S" -- 02- Date wanted: ,r'' i' 4 a Pro ct4 .45(. ‘ .. ,,,z .- 6.. 4 . Type inspection: Ad ress: Da a called: Special instructions: Date wanted: a.m. p.m. Requester: ,.."512 Pho�n No.: A t ...'! ry! ' i* t" �{` 5 !+;nett:••*!c}'KS,..N.: •,'_•.'?E." ,gr7^'rarp.7 -f, INSPECTION NO. INSPECTION RED Retain a copy with mit CITY OF TUKWILA BUILDING DIVISION C 6300 Southcenter Blvd., #100; Tukwila, WA 98188 11 Approved per applicable codes. Receipt No.: /IA 9 8 -cy PERMIT NO. Date:_ (206) 431 -3670 Corrections required prior to approval. $42. 0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: gr _ o. Alove,,e, t /cr..p, geot gr- , itc, ' 5 6 X -) AT - ig_c_ 2 ry ,,(j rS ac.f1r` iA14 I Q 6 zoiQecte 4-At.* A/0-7- 067„..pg. _ A r s Special Date wanted L 1 (c/ am Requester d.jL_ , . Pr;j :ct: _ _ Nit .. �:! i.. 1e. t r- of i - •: tion• di ' C - i+�;�rsrif'r' ate cal ad: _ A r s Special Date wanted L 1 (c/ am Requester Phon 311,3 INSPECTION RE - D Retain a copy with `'': mit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Inspec Approved per applicable codes. morzio c). PERMIT NO. (206) 431 -3670 Co'rections required prior to approval. Date: $42.00 EINSPECTION FEE REQUIRED. Prior to in pection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: P of 1ect: —�` r Ty�e.�of� inspec Address: 1 U C. �fti, k �. �, `- /1 ,� Date called: Dat • 1'2-/ I a / /ff.' Special instructions: �F ten . 1 Date wanted: a. . Request a : Phone No.: to (o to 39 /3 VIryllrrtMlinf6allip94 Approi7l d per applicable codes. l INSPECTION R Retain a copy wit , rmit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Date: Mi g_ C‘d PERMIT NO. (206) 431 -3670 Corrections required prior, to approval. COMMENTS: $ ° V 5 6 a4 ry wf% -z r o Li $42,00 INSPECTION FEE REQUIRED.. Prior to insp = ction, fee must be paid at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. Receipt No.: Project ..e If'eZ. -- Type of i ction: (.(I'CS C01/�t A dr ^ f dr 7b 5 , t� '/� C (( 1 t/ � Ma � O` Date calla j oil 4 a. Special instructions: Date wanted: �a, Requester :a v V Phone No,' r` i. .r 3 '" X�; 115• `: ';"`&:' �'-•7 INSPECTION RE Retain a copy wit INSPECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 (206) 431 -3670 Approved per applicable codes. I f Co actions required prior to approval. COMMENTS: Date: $42 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Pr ' ct: of e 1°,4v ��� Z 5 n� G � T�of in �ecti • $p w e ca drl ! 2, / 16 a 1 181 .. s6: J. C - k , /tiau o Special instructions: `2e1 - D Date wapt f / 1/* Requester f rees P roz . n. 30_ i(k INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 A pproved per applicable codes. INSPECTION RE D Retain a copy wit " rmit l\#(9- ow- - I • PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: �. /�c/C.-11 I /' Date:l /3 I $42.00 = EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.. I Receipt No.: Date: PETERSON •:)TREHLI INC. CONSULTING ENGINEERS 820 JOHN STREET, SEATTLE, WASHINGTON 98109 OFFICE (206) 622.4580 / FAX (206) 622-0422 • 1 \ 0 LOC I ' . ( c 1 49 ■ 4 1/4 / i . ( i _ i 1 , • • ■ ■ ■ • • • • • • ■■ 1. • • OM. • • • , 1 .4 ... . 1 .. . 4 , . ..... • . 1 Co 14. re eoLt'=:' If. 'r . .1-- . . i I v), 4 , 1 • I; • di' ma° 'd O'H99H 'ON XVd r • 1 • . 4 . ; . ' " ii • .. , RECEIVED CF 'TUKWILA I . • PERMIT UbNTR ONI WV 080 UM 66-60-83J i I ... /i--- 1 , -- e.. -I-- 1 -,--. 1 ' El PETERSON •:)TREHLI INC. CONSULTING ENGINEERS 820 JOHN STREET, SEATTLE, WASHINGTON 98109 OFFICE (206) 622.4580 / FAX (206) 622-0422 • 1 \ 0 LOC I ' . ( c 1 49 ■ 4 1/4 / i . ( i _ i 1 , • • ■ ■ ■ • • • • • • ■■ 1. • • OM. • • • , 1 .4 ... . 1 .. . 4 , . ..... • . 1 Co 14. re eoLt'=:' If. 'r . .1-- . . i I v), 4 , 1 • I; • di' ma° 'd O'H99H 'ON XVd r • 1 • . 4 . ; . ' " ii • .. , RECEIVED CF 'TUKWILA I . • PERMIT UbNTR ONI WV 080 UM 66-60-83J p ETERSON Z)TREHLOTARTINSON, INC. CONSULTING ENGINEEIsS • 820 JOHN STREET, SEATTLE, WASHINGTON 98109 OFFICE (206) 622-4580 / FAX (206) 622-0422 ; '' • t .. ...,....)‹. 4-,T- ..\\/. , , .,• 4. C4 P.0/20 'cl A --ri- ' C'-.' •_.....u. _..c....\)s` ck. .._._ ..,f..•.cy.b.,... ...... ..$).E.44...c 1 ili! 1 4 , , , .., :•,, I , C.) , , : - F' I -::: I . - - ' L . , 1 . - • : 1 , 1 i j i i , .._4.... .1 1 1 . ". • " * ; 1 ..1 .. .: , . I : i I i ; . I ; 1 : l ' 1 • It I I . -. , . J00: DATE: 3 — 2:5 Er■ SUISJECT: _ t;, --• Lrt_e___E.1 i.. H • , •._ SL;'t'k i t 14). dirc.f 4- ..,.. :i , , f l i : . .-: -,..1. L 4 ■, ' ' t . HECEIVD...:...... -t.ctel 1 i 1 FEB-F•3! 19j9 • i • , ; . 4 -... - -,.- •i 14 . ...,.. ., ...L i i ...., , , ...,............. I, ' - 7,::)!,..H).44-r - 40, . 64,t• QF PE:Rmai.pgrol..... .e.).1 . ‘,4'6' 4 ..6kpP '1/4_ 1.06A-0 33V0339903 'ON XVE ONI 1.1k) 83:80 03M 66-80-838 Coolin: Equi .ment Schedule Equip. ID Brand Name' Model No.' Capacity Total CFM OSA CFM Econo SEER or EER IPLV Location AC-\ fr(t nd yr1)18 , 1 t 1.1) CID \ 0c CD H.(p N /I, oc p(` Ty nfi «/ (t - )(f -) ' /Z_ ,c.- c.,vo C. c1, - 1 .,) ti� /f . 1113 C) F \..r5 - Tro_rw L-/0 .1)(D ?1 — 1 ' (a Cx-)c) q,vo C1 .-1 t•.\ /1 \ / -I rx'- tl -- r (,.r 1( / r i )U-1 a Q,3 t\ 1 7 i' L) L- U 0 1 C) . 0 r,.? IA j \ t `) - Ira ra r r • V C.1)09 Cx.3 `1 72 y .) 0 r2? 0 ` \ , "1% I.3 /A. E T , - 1 1 --T—Ka I tr \ / U ( 3 LA i 1.c.x.7 tI c.7.2 1 0 1.3 /i�.• _L Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP/BHP . Flow Control Location of Service I'c=) l D'i 1 \L -C Car.i4 - - 13 1 ti () n ?), v 72 C E= • :' It_.('' t i^12bA- 13 1"ca(2 '/2 s 0 .,(.. 1l,CICS- -I $ 1113 C) :)r''i.iri rio ' ib 3,o Z.S(a 1 . 1 ' La I L On (12.1 - 12 7 5o \ / -I Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Total CFM OSA cfm Econo Input Btuh Output Btuh Efficiency' l D'i 1 •1.)f 1.I /4. 1 IOW N....1 /A- ?), v 2. v E '-/ , s 0 &DI's :)r''i.iri rio — 3,o Z.S(a Project Info Project Address \ [ , ( -,n 1 .( . 1 I .r. (/ i 'A - P- V vl !)0'31 ncA (1-fr Date q %� i C/ I ' J For Building Dept. Use Applicant Name: ". 7 � I � - � ' �tr � � Applicant Address: r- t , ' c:.'(- A c, y k1 Applicant Phone: ' - : -v .1,/ ,c ,,.. n j' /:::--,-- *. 1994 Wanhmglon Slate Nonrecloenlle! Energy (of `n1pllance 1'ormL Jul), 1991 Project Description Briefly describe mechanical system type and features. 12-c Pik, r\c owi - y t£'o k rS O S srx-. ckuC(GWor( ,'Simple System ❑ Complex System ❑ Systems Analysis (See Decision Flowchart (over) for qualifications) C ompliance Option Equipment Schedules The following Information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill In the required Information below. 'If available. S As tested according to Table 14-1,142 or 14-3. Flow control types: VAV, constant volume, or variable speed. 9 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. s OF T dITY UUKW11„p SEP 2 3 1998 PERMIT CENTER Fizecte-Oso Mqs.rAz System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <54,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? 1994 Washington State Nonresidential Energy Cooe Compliance 1171E0.1-SUM Decision Flowchart Use this flowchart to determine If project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. System Type 5000 cfm? <70% OA 54,000 Btuh 1900 cfm onstan olume it Cooled? Split stem ,000 Btu r 1900 cfm Heating Only no 1994 Washington State Nonresidential Energy Code Compliance Form yes ackage yes stem no C . 1 R eference Sec. 1423 J Simple System Mowed Reference Sec. 1420 yes yes no no r Use Complex Reference > System Sec. 1430 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. • ( i':..•'+ r •i.ai u,. 4 Jt, tie;,iueritil:I July, 1994 1994 Washington State Nonrestoantial Energy CU mptienco Forams ` Project Address Date The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (circle) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Eqpmt performance Yes no n.a. 1411.4 Pkg. elec. htg.8 cig, List heat pumps on schedule Ted no n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1412 HVAC controls yet+ no n.a. 1412.1 Temperature zones Indicate locations on plans yea no n.a. 14122 Deadband control indicate 5 degree deadband minimum yea no n.a. 1412.3 Humidity control Indicate humidistat yes no n. ■. 1412.4 Automatic setback Indicate thermostat with night setback and 7 dlff. day types yea no n. a. 1412.4.1 Dampers indicate damper location and automatic controls yes no n.a. 1412.5 Heat pump control indicate microprocessor on thermostat schedule yea no n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes no n.a. 1412.7 Balancing Indicate balancing features on plans yes no n.■. 1422 Thermostat interlock Indicate thermostat Interlock on plans .) no n.a 1423 Economizers Equipment schedule "- 1413 Air economizers Indicate 100% capiE(Ilty on schedule yes no. n.a. 1413.1 Operation yes no n.a. 1413,2 Control Indicate controls able to evaluate outside air yes no n.a. 1413.3 Integrated operation Indicate capability for partlal,cooling r 1414 Ducting systems yel no n.a. 1414.1 Duct sealing Indicate sealing necessary ye...,no n.a. 14142 Duct Insulation Indicate R -value of Insulation on duct Ye. no .eis.al 1415.1 Piping insulation Indicate R -value of insulation on piping yea no n. a. 1424 Separate air sys. Indicate separate systems on plans ye no Mech. Sum. Form Completed and attached. Equipment schedule with types, "". Input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yea no n.a. 1441 Elec. water heater Indicate R•10 insulation under tank yes no n.a. 1442 Shut -off controls Indicate automatic shut -off 1450 Heated pools yea no n.a. 1452 Pool water heaters Indicate not electric resistance yea no n.a. 1453 Pool heater controls Indicate switch and 85 degree control yes no n.a. 1454 Pool covers Indicate vapor retardant cover yes no n.a. 1454 Pools 90+ degrees Indicate R -12 pod cover — If "no" is circled for any question. provide explanation: • ( i':..•'+ r •i.ai u,. 4 Jt, tie;,iueritil:I 1994 Washington State Nonresidential Energy Code Compliance Form JII"�1s7T11 p_ Misr Chest:fist " 994 Washington State Nonresiaontial Energy Cooe Compliance ones =CH-CM July, 1994 Mechanical - General Requirements 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by Individual therm static controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone Is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls we not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints we set to the same temperature . between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods d non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock end be capable of being set for seven different day types per week. Exceptions: 1. Systems serving antes which require continuous operation at the same temperature sotpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off- hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shell be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open dampers. These dampers shall remain closed in normal operation until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Hosting Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btilrh shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing wives. 1413 Air Economizers 1413.1 Operation: Air soonombmers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply sir as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shell be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct oq:ension, cooling systems with capacities not greater than 75,000 Btu/h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 12 inch water column static pressure shall be sealed in accordance with Standard RS-18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal ail transverse joints, longitudinal seams and duct wall penetrations. 1414.2 Insulation: Ducts and plenums that are constructed as part of the building envelope shall meet the requirements of Chapter 13. Other ducts and plenums shall be thermally insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1415 Piping Systems 1415.1 Insulation: Piping shell be thermally insulated in accordance with Table 14-6. Exception: Piping Installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: a. Air cooled, constant volume padeged equipment, which provide heating, cooling or both, and require any edema) connection to duct work and energy services. b. Air cooled, constant volume split system, which provide heating, cooling or both, with cooling capacity of 54,000 Bluth or less. c. Heating only systems which have a capacity of less than 5,000 cf m or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other system shall comply with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements in Section 1412, where separate heating and cooling equipment serve the same temperature zone, thermostats shall be interlocked to prevent simultaneous heating and cooling. 1423 Economizers: Econornaers meeting the requirements of Section 1413 shall be installed on packaged roof top fan - cooling units having a supply capacity of greater then 1,900 cf m or a total coding capacity greater than 54,000 Btu/h. The total capacity of all units without economizers shall not exceed 240,000 Btu/h per building. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by . separate air distribution systems from those serving zones requiring only comfort conditions. Project Address t Date The following additional information Is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this Information In separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (circle) Code Section Component Information Required Location on Plans Building Department _ Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY yes no n.a. 1431.1 Field assem. sys. Provide calculations 1432 Controls yen no a.a. 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2 Temp. reset control yes no n.a. 14322.1 Air systems Indicate automatic reset yes no n.a. 14322.2 Hydronic systems Indicate automatic reset yen no n. a. 1433 Economizers Indicate economizer on equipment schedule or provide caluulations to justify exemption yes no n.s. 1434 Separate air sys. Indicate separate systems on plans yes no n.a. 1435 Simul. hig. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified yes no n.a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations yes no n.a. 1437 Elec. motor efflc. MECH -MOT or Equip. Ehe`dtiie with hp, rpm, efficiency yes no n.a. 1438 Variable flow sys. Indicate variable flow on tin and pump schedules 1 �V{e>c'hanii1 - c Complex �ist 1994 Washington State Nonresidential Energy Cor - npiance Forms t ''4.1't7 € ll f If "no" i s circl for any ques provide exp Decision Flowchart Lir Section 1432.2 Hot Water Supply Tempasturc Reset Controls Required Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete Information on the requirements. Section 1411.1 5quipmeat Pat. Shall Meet Tables l.4-1 through 14-3 V Section 1431.1 Calculations of Ton) On -site Enap Input & Output Requited (continued on back) July, 19P4 09/23/98 WED 08:46. FAX 206 916 2095 TRAfiE .; Tag: All'dimensions are in inches EVAPORATOR SECT ACCESS PANEL 5y. Ih NPT GAS CONNECTION coknot. a COMPRESSOR ACCESS PANEL CLEARANCE 36 133%, O..EARANCE 46 Table 2 Accessory Net Weights (LW Economizer Outside Air Gamper Nee Ship Motorized Manual 40 55 • N/A 32 GENSCO /TRANE TOP PANEL 460 CLEARANCE 36 4 TYPICAL. ROOF OPENING CONDENSER FAN 33 I_ 46 NG CLEARANCE 36 Table I Unit Wiring CONDENSER COIL —2 01A tIOLE turuT PGWER WIRES) 7 / e OA ROLE (UNIT CON1P4 . WIRL31 Unit Unit 012eradn0 14odel No. Vottape Rave YCO048C1 187 -253 'rc0048C9 167 -253 YC17048C4 414.506 YCOO48CW 517.633 NOTES; 1. NACR boaYee po NT.C. Roof Curb 80 NOTES: 1. LAW on 1 phi.* 0*. 2. Nw w+y• Mould awed a wtil vr•IeiI v tmA adirtro wort 'MAW oorrnrr. Oversize Motor 24 Pitadis-olo M'S8.O(ta1 l 002 YCD0484Q- 21 4,04 Minimum Occult ArrifwiTY Standard/Oversized 36./38.7 24.81272 11.9/13,0 9.5110.2 Nude S INS Kit 5 lPG Conversion Kit . • 4 Ton Downflow Gas/ Electric Packaged Unit YCD048C Maldnrm Flee Site Or Merrtosn drallt Brume Standard/Oversized 0160 35/40 W20 15/15 AW Zona S•neora 1 RECEIVED CITY OF TUKWILA SEP 2 3 1998 PERMIT CENTER 09/23/98 WED 08:47 FAX 208 R 2095 Table 3 General Data Cool eg Perfennafte.' • • GPI. Qooing Cs yscity Nomind CFWARI Rated CFM 1600/1603 1600 / 1600 • M Nat Cooing Capacity 46,000 47,000 System Pow r (1(W) 5.34 5.26 Hating teerformence Muting Models Low high Low High Heating input (RA 90.000 120.000 90,000 120.000 F4oe6ng Output (south) 70.000 94,000 73.000 97,000 PFUE9lW 76 78 81.0 61.0 Steady State Efficiency ( %) 00 60 81 81 No. Sumacs 1 1 No. Stages 1 1 Gas Connection Pipe Site (n) 12 1/2 Compressor No./Type 11CfrruMf 1 C irnaMf"r Sound Raring (BEL$)' GENSCO /TRANE (. YC0046C1 YC0046C3. C4. CW 49,900 48,900 10.00 10.00 8.6 6.6 Outdoor Coll - Type 14Rerlornr ce FS-Performance Tube Size (it) 00 .375 975 Face Area (el h) 7.43 5.87 Fi<swslFPS ?116 2/16 Indoor Coll -Type 1-4.padormnce ili•Perfortnarice Tube Size (rt.) .375 .375 Face Nee (sq ft) 4.63 4,13 Rowe/FPI 2115 2/15 Refrigerant Control Short Oros Short Orifice grain Connection No/Size (h) 1/ 3/4 PVC 1/ 3/4 PVC Outdoor Fun -Type Propeler Propeller No. Used/Dlemater (kt.) 1/24 1/24 Orire Type/No, Speeds O'ireW1 Dkoct/l . CFMr 3940 3630 No. Motora/VG' 1/.33 1/.33 Motor RPM 1075 1075 Indoor Fan - Type FC Centiiugal FO Centrifugal No, UserflDtsmerer (h) 1/12X 9 1/12 X 9 Drive TypMNe. Speeds Direct/2 DirecV2 No. Motors 1 1 Motor HP (SlandarNWeremed) .501.75 .50175 Motor RPM (Standard/Oversized) 850/1040 850/1040 Mohr Rams Stye (Standard/Oversized) 48/46 48148 Mere - Typo Fur ? es Yoe Throwaway � cws (No.) Size Recorm endsd (2) 20 X 25 X 1• (2) 20 X 25 X 1 RebigeraM Charge (Lb* d R-22) 6.6 5.8 f 14370 1. Goofing P.Aomnnee Y mud at 96 F tartlet I O F wearing dry bs4b. 871 entering we tub end rarnid can feet. AM rung corn Y 330 demon for Cis pan c. Grac. cap.do, don not Indud. n. Wool of Mn moor Met MI capacity it nl and Irdudes the .flag or tan near heat %Ma me .ilea% a operation C raft d nentiel can. Reed in ecoorearre with ARI Sanded 210. 25[!11 to trod at MU conSdon and h woardana viot DCG tel procedures. 3. Honing PNkaaMMa Est so iys ud ranter data were NrebWwd and appto od undo( Iebonlay last cordion@ Woo . A,nrimi Nola* S udude Indlas 'sanded.. Mies shown ore IN stroberd s ft 2000 feet For alevatime abv+• 2000 feet ratings as /educed rM rob d 4% kr each 1mg bet above ma lord. 4. ARMY rated In a000rdues a4ft DOG WI pl000duoi. 6. Aid Sound Rains is rated h accord si a with MI Standard 270, s. ded.or Fan dm Is rated ern standard et-by ooi outdoor. 7. Perigee. Worps Y an speraa:rlala value. For a more prods* wlie,'ae• unit nn".ptaio and **vice tratneiors. x003 09/23/98 WED 08:47 FAX 208 , 2095 GENSCO /TRANE inches . All dimensions are in ECO OM Center Of Gravity Center Of Gravity Width STANDARD END ,PANEL Of UNIT ECONOMIZER HOOD Center Of Gravity Length 3 NOTES: 1. Crnr .+AMU M• y'«in W inleemlition on if Compressor 22-3/16 Table 4 Maximum Weights, Come' Weights And Center Of Gravity Dimensions 39.7/0 2 -7/8 C a 3-311 3 /t' PVC Cond,ssat. Loaetion • Maximum Weight (Ibs) Corner Weights (Ibs)' Center d Gravity (in-) Shipping Net A B C 0 Length Width 811 639 216 169 123 142 • 37 10 el 004 414m M M6h A11C 44M SC MW SC MEh 6HC •.ih SIC IMh SING 1469 57C MIh f/C MM SIC NM 6110 MEh 01C MM SHC MC 75 431 36.7 91.4 MI WS 161 42.5 W7 4641 245 527 164 383 31,7 462 267 50.2 17.1 340 251 41.1 248 474 71 A 1440 M 441 411 61.7 3441 544 344 47.6 402 466 333, 53.0 25.1 355 363 464 31.3 5114 316 35.6 366 413 292 '472 a 210 NO AS 47.1 474 611 scam 311 44.7 0,7 44.2 288 3+ 31A 411 411 443 37.7 60.6 216 367 3E.7 413 33,6 172 263 254 60 110.3 602 633 141 163 37.6 47,E 471 463 451 617 366 445 444 462 412 61.0 364 M4 4141 41.9 413 474 34.4 ilia 76 47,1 VA 672 29.3 64A to 431 36.7 46.7 WS CM 16.7 165 316 N,4 261 s117 17A 36A 313 42,2 240 471 166 1600 M 47.6 447 526 38. 634 772 442 424 Ml 34.7 53S 215 40.4 444 Mb 33.0 510 246 372 372 423 31A 47A 22A 24,1 II 414 41.4 626 42.4 660. 34.3 40.1 43.8 1141 473 WA 320 43.6 434 467 40.0 612 313 444 40w 4 *0 48.0 217 346 90 614 611 63.2 451 565 341 Ml 45A 606 464 544 362 462 443 47.5 47.2 61.7 374 416 434 417 417 463 364 37,1 75 462 316 521 343 86.2 241 446 373 603 255 WS 160 406 16.4 472 27.1 51.1 17.7 360. 33,3 410 35.1 44.1 161 176) M 446 472 63.1 3 667 350 464 441 501 361 619 264 414 41A 471 3.7 51S 25.7 366 366 17.1 324 46.'1 33.7 243 M 501 0.41 616 44.1 662 33.7 467 461 601 43.4 544 31.4 462 462 474 422 611 320 413 411 414 403 466 109 311 90 612 612 640 61.1 574) 365 616 51A 61S 607 640 314 467 46.7 464 464 52.3 31.6 463 443 45.4 444 46,5 360 366 76 466 412 632 311 66.6 204 464 353 649 217 WA 11.3 41.6 372 471 261 61.4 171 37.3 341 07 241 464 163 1S@ 60 424 464 636 WA 560 2A,6 464 464 61.1 57.4 543 273 413 433 471 361 61A 241 3141 389 416 342 4 67 244 23.7 AS 613 511 641 464 664 34.0 40.6 418 615 441 511 33A 447 467 463 44.7 523 329 417 417 444 425 463 313 U.S 70 642 642 647 621 8.72 40.7 621 621 52.1 521 664 444 43.5 453 46.6 48.3 WA 4 02 46.6 46.5 46.3 469 VA 365 fVho.+ 5 Men 5NC W10, 544C Men PC Meth DC Men SIC Men SIC M6h SIC WA 6I4 Meh PC MEh SIO 4441►1 MC M61. AHC 76 466 352 640 294 NO 15.4 MA 333 472 260 51.1 16.1 360 31.4 443 20.3 45.1 147 342 293 402 34A 464 163 1x40 60 45.3 41.7 601 342 NA 261 421 3.18 460 327 622 24.7 317 379 443 30.1 432 232 NO 360' 40.4 219 466 71,6 65 447 45.7 661 444 54.7 311 440 460 462 35.1 52.4 347 01 41.1 446 273 416 254 36.0 340 404 38.3 442 273 90 40.6 466 614 441 662 574 47,1 47,1 464 456 621 366 443 442 40.7 43A 46.8 ilia 41.1 41.1 412 412 443 34,1 76 462 372 61.4 21A 546 16.0 4.3.7 36.7 44.7 27.1 623 164 36A 333 457 216 417 17.0 34.1 71,2 012 238 46.4 16,4 1600 60 447 447 61,7 66.7 64A SW 43.4 42:6 413 34.3 67.7 251 30.7 347 465 32.6 463 24,1 36.5 368 412 300 401 32.4 43 467 467 613 433 187 340 463 463 411 412 63.1 3 423 423 4 8.7 36.6 502 346 337 347 N,7 37,7 43.6 20,2 60 612 612 82.4 400 18.3 343 446 461 40 440 530 360 461 461 482 462 60.6 37,1 430 430 431 411 47,1 365 73 472 311 670 261 641 153 417 37.1 463 744 527 160 749 311 40,7 267 501 177 337 230 42.0 24,7 466 147 um AO 471 468 63.3 341 653 274 44.3 443 MA 36.8 612 3/4 412 412 462. 347 60A 243 329 37A 421 323 47.1 23.7 e5 641 60.1 627 440 6341 *5 47.8 471 441 411 610 NO 446 446 443 415 SW 311 412 412 434 440 474 304 90 626 615 633 614 644 381 602 502 606 603 64.1 362 473 47.6 473 471 612 366 444 44,4 446 441 47.7 776 7$ 461 .409 124 30.6 661 302 445 MA 469 734 610 10,0 447 366 446 27.7 604 773 766 3441 427 258 472 156 i53D b 441 40..0 673 360 666 266 467 467 502 37.1 615 27.3 47a 42.3 468 317 50.6 23.7 31.1 3a.1 47.6 31A 473 340 e5 612 612, 677 452 662 340. 466 468 608 448 540 334 459 461 472 431 612 U.S 42.3 426 433 411 473 711 70 53.1 WS 14A 62.6 64.6 104 612 61.7 613 610. 646 402 466 46,6 447 467 61.7 3116 163 448 46.6 466 462 356 09/23/98 WED 08:48 FAX 208 926 2095 Table 5 Gross Cooling Cap( ,4a (MEW 4 Ton Single Phase YC0048C1 A..I:i4.4 T•rpra►4 1 EnW. Cry 61 O 17 73 AI M GENSCO /TRAKE Anon MM bob M 73 II 110031 1.41 cam: 4W shoom , 9ors and na.• nm earid...d Y..bw' Ian h.+. To obsaln not cooling Mom* indoor fan nom. 1 We To ul Gems Caforisy 3. SIC • SenoWo 14444 Gpah f 106 Table 6 Gross Cooling Capacitiei (MOhN 4 Ton Three Phase YCD048C3,C4.CW &me. CITY 44 115 M doom Tw.wwua 61 Swing W41own 61 67 73 Q1 67 73 6I 105 710761: 1.46 apodd4a Maws ens yew .44 Woo nos onuba,w Indoor Ian heat To osnln ow amo w7' 4G indoor fan ha . 2. MMh • Tod Croa Cap4tiry 3. 6716 • r5 3Ia Haw Ca ath 47 77 61 67 67 73 61 115 116 67 73 09/23/98 WED 08:49 FAX 206 0 2095 GENSCO /TRANE Table 7 Electrical Characteristics -- Evaporator Fan Motors - 60 Cyds Standard Evaporator Fan Mar Oversized Evs ,.ov or Fan Mater Mee Unit Model No. No. Vohs Phase HP FLA LRA No. Veils Phase HP YCD049C1 1 208 -230 1 .50 4.2 9.2 1 208230 1 .75 6.0 13.1 ¥00048C3 1 2.330 1 .50. 42 92 1 206-230 1 .76 6.0 111 YC0048C4 1 460 1 .50 2.0 4.3 1 460 1 .76 3.1 6.6 YCOO48CW 1 575 1 .50. 1.9 3.4 1 676 1 .75 ' .2.4 r5.2 Table 8 Electrical Characteristics - Compressor Motor And Cendenaar Motor - 60 Cycle Unit An' Amps' Model No. No. Vohs Phase HP RPM MA LRA No. Phase HP RA LRA YC0648C1 1 208 -230 1 4.00 3450 24.0 118 1 1 .33 21 4.8 YC0048C3 1 208-230 3 4.00 3450 14.8 101 1 1 .33 2.1 4.8 YC0048C4 1 460 3 4.00 3450 7.1 51 1 1 .33 1.0 2.6 YC0048CW 1 675 3 400 3460 5.5 41 1 1 .33 0.9 2.1 NOTES: 1. Amp draw for aostt moor, mut*, Mug W numbsr of moors to d•rrmina natal amps Table 11 Static Pressure Drops Through Accessories (Inches Water Columny Economizer with OA/RA Dampers' CFM Filters) 100% OA 100% RA 12E0 0,04 0.06 0.01 1600 0.06 0,08 • 0.02 1920 0.09 0.10 0.03 NOTES: 1. OA. .OgtoIds r4r and M a Raman Air, Compressor Mattes Condenser Fan Motors Table 9 Combustion flower Motor Data Heat Law Heating Am ps Stages HP RPM Vohs Phase PA LRA Table 10 Evaporator Fan Performance Table 12 Gas Fired Heating Capacities Unit Model No, 1/20 ' 3350 208 -230 1 0.4 1.00 Ea:P enal Static Prams. (Incases of Water) & Motor Power (eta' Standad Wear Overshoe Mesa men Soeed Low Speed Unit Model No. C714 ESP BHP ESP BHP ESP 1200 .83 .48 .78 .35 - 1300 .71 d8 .70 .37 1.56 1400 .75 .60 .62 .39 1.45 YCD048C 1 d. 1600 .71 .52 S4 .42 1.36 Y00048C.1.04.CW -LH 1600 .65 .54 .46 .44 1.29 1700 .59 .66 .30 .49 1.20 1800 .52 S8 - - 1.10 1900 .44 .00 - - 1.02 2000 .40 .tit - - .92 AmPII RA IRA 1200 .82 Aa .75 .33 - 1300 .78 .49 .68 .37 1.55 1400 .73 SO. , .60 39 1.44 1600 .69 .52 .112 A2 1.36 Y0304801.11 1000 .63 S4 .44 .44 1.27 1700 .57 .56 .28 .49 1.18 1800 .50 58 - - 1.08 1800 .44 .00 - - .99 2000 .38 .62 .90 Fan maw heat (Meld a Va a ran are Trance %O 7 Novara mr vas. In mnm.rdd salaam r, ere armee awes mane apdarYY chap ad aria pus w s91111M 1N640Y MI oaAiawtdV a as cataloged rnndalra. Uatrg /o AA hosa0owr flora al oar ti MOM" as warn N ow taeutl awe we not Tool In 101 U Tea tripping w pramstura moor liked Out prodra'a wtaramY will mat qa aHaoad NOTES: 1. Ora mouse yew. woe eon a wet cei and Mrs. YCD048C14. 94000 70,000 3545 NrcodaC1I4. 120,000 94,000 3545 YC00411C3. C4. COWL 90,000 73,000 3545 YC0048C3, C4, CW-H 120,000 07,000 3646 AY Temperature Honing k1p11 M8h Heating Output Meh Fie )lunge ram 09/23/98 WED 08:49 FAX 206 9-26 2095 GENSCO /TRANS Mechanical Specifications General Units shall be dedicated downflow airflow. Operating range shall be between 115°F and 0°F coding as standard from the factory for all units. Coding performance shall be rated in accordance with DOE and/or M tasting procedures. All units shall be factory assembled, internally wired fully charged with R -22 and 100% run tested before leaving the factory. wring internal to the unit shad be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to ANS1721.47 for gas fired central furnaces and UL 1895 /CAN /CSA No. 236 -M90 for central cooling air conditioners. Canadian units shall be CSA certified. Cuing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel Exterior surfaces shall be cleaned phosphatized and finished with a weather - resistant baked enamel finish. Unit's surface shall be tested 500 hours. in a satt spray test in compliance with ASTM 8117. Cabinet construction shall allow for a0 maintenance on one side of the unit Service panels shall have lifting handles and be removed and reinstalled by removing only a single fastener on the units while providing a water and air tight seal The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1W high supply /return openings to provide an added water integrity precaution, if the'condensate drain backs up. The base of the unit shall have provisions for (orkhft and crane lifting. Unit Top • . The top cover shad be one piece or where seams exist it shall be double hemmed and gasket sealed to prevent water leakage, Filters One inch, throwaway filters shall be standard on all units. Fitter reds can be converted to two Inch capability. Compressors Compressors shall be direct drive hermetic, reciprocating type with centrifugal oil pump providing positive lubrication to moving parts. Motor shall be suction gas - cooled and shall have a 6 voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Crankcase heater. internal temperature and current- sensitive motor overloads shall be included for maximtim protection. Shah have internal spring isolation and sound muffling to minimize vibration transm and noise. Low pressure switches shall be standard. Refrigerant Circuits Each rehigeram circuit shall have independent fixed orfice expansion devices, service pressure ports and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. Evaporator And Condenser Cons internally finned W copper tubes mechanically bonded to configured aluminum plate fin shall be standard. Coils shall be Teak tested at the factory to ensure pressure integrity. The ovaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 psig. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components. A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative pressure gas valve shall be used that requires blower operation to initiate gas flow. On an initial all for heat, the combustion blower shall purge the heat exchanger 45 seconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane (field installed kid and also comply with California requirements for low NOx omissions. Un shall have a single stage high or low heat option. Outdoor Fans The outdoor fans shall be direct drive, statically and dynamically balanced, draw through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and have built• in thermal overload protection. a 007 09/23/98 WED 08:50 FAX 206, 2095 GENSCO /TRANE Mechanical Specifications Indoor Fan The units shall have a direct drive, FC centrifigai fan. Ad motors shall be thermally protected Oversized motors shall be available for high static operation& Controls — Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Units shall Provide an externs( location for mounting fused disconnect device. Micro-processor controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling and/or ventilating dadsions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point and provides better building comfort A centralised Micro-processor shalt provide and -short cycle timing and timo delay between compressors to provide a higher level of machine protection. Accessories Roof Curb —The roof curb shall be designed to mate with the downflow unit and provide support and a watertight installation when installed Property. The roof curb design shall allow field-fabricated rectangular supply /return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall ship knodted down for field assembly and include wood nailer strips. Economizer —This accessory shall be either field or factory installed The assembly includes — fully modulating 0 -10096 motor and dampers, barometric relief, minimum position seeing, preset linkage, wiring harness with plug and fixed dry bulb control. Solid 'state enthalpy and differential enthalpy control shall be a factory- supplied, field - installed accessory. The factory- installed economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. 7 • Remote Potentiometer .—The minimum position setting of economizer shall be adjusted with this may. Manual Outside Air Damper — Field installed rain hood and screen shall provide up to 25% outside air. Oversized Motors — Mold or factory installed oversized motors shall be available for high static applications. Co ot Guards — Coil guards shah be field installed for condenser col protection. Control Options Trane Communication Interface (TCI) — Shall be provided to interface with the Trane Integrated Comfort"" System. Zone Sensors -- Shall be provided to interface with the Micro equipped Voyagers and shall be available in either manual, automatic programmable with night setbadc, with system malfunction lights or remote sensor options. Convendonal Thermostat Interface (CTI) — This field installed circuit board shall provide interface with electro- mechanical thermostats or automation systems. Differential Pressure Switches — This field installed option allows Individual fan failure and dirty fitter indication. The tan failure switch wail disable ad uncl functions and 'flash" the Service LED on the zone sensor. The ditty later switch will light the Service LED on the zone sensor and will allow continued unit operation. Input / Output expansion Accessory — This kit allows Integrated Comfort"' Sytema to reed Supply Air Temperature, Return Ak Temperature, Return /fir Humidity, and direct indication of fan failure without the use of an economizer or motorized outside air accessory. Electronic Time Clock —This field Installed accessory Idt will allow the unit to operate in the unoccupied mode or perform night setup/setback functions utilizing a standard individual scheduling. Zoos 09/23/98 WED 08:51 FAX 208 '6 2095 OTRAN • .. 'Tag: All dlmension2 are In inches EVAPCOATOR SECT ACCESS MEL y NAT GAS CONNECTION CONTAIN. & COUPREVAIR ACCESS PANEL. CLE 36 CLEARANCE 40 CLEARANCE 36 Tabla 3 Accessory Net Weights (Lbai Economizer NON Ship 40 70 40 P1CAL ROOF OPENING Omsid.Atr Damper Motorizad Manuel 35 32 TOP PANEL Unit Model No. YC002OC3 1C.'O000C4 YCOoaocW .49 AmassorY Modal Number BAYPWRX013A BAYPWRX015A SAYPWRX014A Pool Curb 82 NOTES: 1. No vapid tWd be amid to wit vw40P1 worn.eMlp *my VaeNsdoranwwhr. GENSCO/TRANE CONVERSER TAN 46 lig CLEARANCE 36 Table 1 Unit Wiring CONDENSER COL 2' 04A Nat tuNST POOTAI MIRES) >% WA NOLE (UMT =mot. WIRES) Wit Operating Vakaps Range 187 -253 411606 517.633 NOTES: 1. MGR beaker pen NEC. 2. Valves der not Incuds power odwrrt •cGcy. Table 2 Electrical Characteristics Power Exhaust Accessory Airy Operating Voltage Ph.. HP 206 -230 480 575 Overlies Moor 45 1 ing Mq s - XCDO9O.SQh217.,04 SUBMITTAL 7 /2Ton Downflow Gas/ Electric Packaged Unit Single Compressor VCD090C kreirrurn Ctrcuk Mtpatig StandardNversited 43.1/46.0 20.9/22.1 16.7/172 'F 1 8144 Power LPG Conv.rsion All Zon. Exhaust 05 Kit Sensors 5 1 MadrtKrn Rea Size Or Circuit Breaker' 00/60 30130 25/23 Amps PPM FLA LAA 1100 6.6 13.5 1100 3.1 8.4 1100 2.4 5.2 Z oo9 RECEIVED CITY OF TUKWILA SEP 2 3 1998 PERMIT CENTER ' 09/23/98 WED 08:51 FAX 208 926 2095 GENSCO /TRANE Table 4 General Data Compressor No/rype YC009oC 1, C4,CW Cooling Performance' Otoes Cooing Capacity 92,000 Nominal CFM / ARI Rand CFM 3,000 / 2,625 ARI Net Cooing Copecks 88.tb0 ' k eargre ad Part Load Value — System Paver (KW) . . 178 Heating Ped.tmancel Hastily Modes Low High Healing Input (Bk h) 120,030 205 ooa 1st Stage Urlta Only 150,000 Heating Output (Nun) 97.000 168.000 1st Stage Untie Only 122,000 MLElie 81.0 81.0 Steady State Efficiency 81 81 No. 8uners 1 Nn. Stages I 2 Gas Conneelion Pip. Size (at) 1/2 1/Trane H eourld Rating (Ba sr 8.8 outdoor Cod • Type FFrPafamertcs , Tube She (In.) OD 375 Face Area (so a) 12.00 Rows/Fp1 2116 Indoor Coil • Type 14Pertorrrtrtce Tube Site (nn) .375 Fad Anse (p n) 7.88 IbwalFPf 3115 Relrigerer* Control Shod Orifice Drain Correction Nol5tze (h) 1 / 14 PVC Outdoor Fn -Type Propeller No. Uaed/Diemater (m.) 1/24 Drive Type/No. Speeds Directi1 CFM 5,450 No. MobxsMP 1/50 Motor RPM 1,075 Indoor Fen -Type FC Centrifugal PIo. Used/Diameter (h.) 1/12X 9 ONG Type/No. Speeds BNVI No, Motors 1 Motor HP {Standard/Oversized) 1.01L0 Motor RPM (Slandsrd/Overehed) 172 Motor Prams Siz. (StanditaOver:1 d) 58r58 RNere -Type Throwaway ($o R co unt:nded (3) 1 Yes X 1 J Refrigerant Charge (tbs of Pr22) 10.8 mar= CooWp P++bmurne Is rend el 86 Fame/ars e3 F entering dry b.m. 67 r OMAN *sabres and narration n sand, ARl milm elm is 330 rAN1on lot Ns product Gross wpedry does not blow. the Onset lore mow hoot ARI repesisy tr net end inductee the Wen wan mew twat UNp are atisobls ran opnarbn b .2071 a noninsi Dirt Reed ti aomrdanoe t must /Vii Sesndaed 210. 2. Healrp Pwrionnonos arlt soolngs and mina data won oviab5thsd and approved under laboratory teat oor ddorw mix; Anrwkan Notional Sttnn.Yds keens, sic derde. Rolm& shown on for elevations up lo 2000 twat Foe areratkra slaws 20031e4 Wm, shoed be reduoad new we d 4% for .00h 1000 Feet above sae level. 3. m us is mod h amordan os viol 001laal pooedtree. 4. Ml Some Rasing is mlid In ecooedaree ester Al Standard 210. 5. R.iignvri chops la an appacinsin vain. Fora more pedal Woo, lee unit rwnwp lee and sonata lnln+a rove. e. LER Is lewd at AM con4liora and in eoeoroLrrn wet 170E Peal procodrses llolo /~ . 09/23/98 WED 08:52 FAX 206 926 2095 GENSCO /TRANE All dimensions are in inches ECONOMIZER END PANEL Center Of Gravity Width Center Of Gravity FRESH AM HOOD pAMWAO STANDARD ENO PANEL OF UNIT ECONOMIZER HOOD Center Of Gravity Length NOTES: I. Cones vetfefee re given tot inlormwwn w*. Compressor S U 354/4 L Y J 15-3/16 no-- 22.1 /2— x- Table 5 Maximum Weights, Corner Weights And Center Of Gravity Dimensions r �-� ---� R E T 43.7/8 U R N I !_ __.l N c l 3-3/B 3/4' PVC Condensate Location 12.16/16 -4-- 3.1/4 Maximum Weight OW) Comer Weights (Ibs)T Center of Gravity (in.) Shipping Net A a C 0 length Width 952 793 262 243 151 177 39 21 Q011 tr... Mreew p) Mal 611C MN 5112 1.1114 521C Mob S1 C Mss 514C M1611 6110 M017 SIC MOS VC WS SIC Man Site 11910 •--*--- t74C • Meh 612 76 663 SSA 16.5 661 100.0 913 723 2+44 002 612 /49 34.3 72.0 601 63.3 641 3122 31.7 547 670 755 443 603 2.1 1700 00 97.1 01.1 917 013 101.0 435 82.4 77.4 916 630 17.0 47.3 721 726 640 60.7 027 44.5 06,0 61,0 753 564 010 415 26 904 014 013 77.0 1020 616 044 644 000 75.2 911 647 710 768 1144 733 010 616 725 72.6 749 016 510 54.1 94 143 943 572 11.6 1050 053 004 2128 614 674 700 664 NA 04.4 654 06.1 017 607 783 7113 70.6 711 87.2 661 75 500 721 306 SSA 1010 303 613 614 01.7 620 97/ 344 729 640 053 405 611 32.4 063 047 774 417 STA 205 3ocn on ass 60.1 17.1 67.7 1070 013 111.0 no 92D 015 112 465 769 741 eV O sit 017 412 617 09,7 773 501 027 413 OS 927 027 07.7 603 1030 611 674 973 33.5 75.1 902 627 130 520 Oil 716 142 617 75.7 717 718 732 610 56,0 00 370. 570 617 93a 1060 713 527 927 011 52.2 1000 71.6 67.5 031.1 57.7 07.7 044 711 614 024 520 120 56a 017 76 900 75.0 07.5 573 1020 375 131 72.1 924 645 90.3 354 765 e62 017 51.4 Zit 330 073 643 717 474 052 301 3300 93 113 90.4 911 69.6 1010 630 043 144 13.2 63.6 900 43.4 714 716 060. 611 343 47.5 772 72.2 79.1 110 Ole 45.0 55 050 060 61! 61.1 1040 674 004 004 919 62.4 1000 666 845 1143 67.7 431 962 604 714 704 00.4 774 650 680 90 606 890 1000 162 1060 714 060 95O 160 960 1010 74.0 900 900 60. 702 160 73.9 WO 64.3 043 ■6 116 724 76 113 717 eta 50.2 10LO 300 047 75.6 917 MA 610 354 770 71.7 971 53.3 944 334 053 674 141 484 no 906 3600 00 024 714 090 71.7 1000 645 VA 070 342 710 89.6 602 02,1 01,1 971 00.0 950 433 74.4 740 004 687 102 463 05 167 161 094 85.7 1040 706 524 724 951 661 1010 67.9 97.1 07.1 910 04,0 954 671 919 919 811 012 993 61.1 . 90 1010 1010 1010 99.3 1010 750 54a 315 904 130 1020 753 510 920 921 221 064 7624 054 264 046 06.2 104 719 Table 6 Gross Cooling Capacities (MBh) 09/23/98 WED 08:52 FAX 206 928 2095 GENSCO /TRANS 012 AnbhntTw/M>•us as 106 116 few+ 4 way. Wit flub ¢i 111 67 73 61 67 71 81 67 75 61 87 73 NOTES I. AS c pact. o shown -, pro and true net onttlewod lnd000 fon nue. TO 60-5415 tat Cooing sobered indoor tan hem 2. M9h • Total Grow Capscrt 3. 311C • S4nabt4 Nyt Capouty Table 7 Electrical Characteristics - Evaporator Fan Motors -- 60 Cycle Unit Modal No. Unit Model No. Standard Evaporator Fan Motor , No. Volts Phase HP FLA LRA No. Volts Phase HP FLA LRA YC0090C3 -14 1 208.230 3 1.00 6.9 32..2 1 208.230 3 2.00 8.8 53.0 Y00090C3•L 1 208.230 3 1.00 5.9 32.2 1 208.230 3 2.00 8.8 53.0 YCD090C4 -H 1 460 3 1.00 3.2 • 16.1 1 460 3 2.00 4,4 26,5 YC0090C4 -1. 1 460 3 1.00 3.2 16.1 1 460 3 2.00 4.4 26.5 Y00090CW -14 1 575 3 1.00 2.6 13.2 1 575 3 2.00 3,1 18.4 Y00090C1N-L 1 576 3 1.00 2.6 13.2 1 676 3 2.00 3,1 18.4 Table 8 Electrical Characteristics - Compressor Motor And Condenser Motor - 60 Cycle Amps' No. Volts Phase It? RPM RLA LRA No. Phase HP FLJ\ L IA 1 208-230 3 7.50 3450 27.0 164 1 1 .50 3.4 10.8 1 460 3 7.50 3450 124 79 1 1 .50 2.4 5.4 1 575 3 7.50 3450 9.8 63 1 1 .50 1.8 4.1 Y00090C3 YC0000C4 YC0090CW NOTES: 1. Any *w /w toot moor, a.Mply value by nun** d motors to drrtrmir total seq. Table 9 Combustion Blower Motor Data Heat Compressor Motors Heating Stages HP RPM Volts Phase R.A. LRA Low 1 1/20 3360 208.230 1 0.4 1.00 High 2 1/20 3530 206430 1 0.4 1.40 Amps Oversized Evaporator Fan Motor Condenser Fan Motors Amps Amps' Amps • 09/23/98 WED 08:53 FAX 20826 2095 GENSCO /TRANE Table 10 Evaporator Fan Performance Unit Model No. Y00090C4.H awful Stara Maur* finches .4 Watts r - .10 30 50 AO .50 .60 70 .60 .90 1.00 • 1.75 1.50 FM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM SHP RPM BHP RPM BHP RPM BHP RPM Otte 1 HP ti..da d Wee* Shown 2400 721 .62 760 .6e 801 .71 840 .7e 679 .60 810 A6 862 .86 NO 521025 .1e 1058 .9S 11421.061226 1.10 2200 802 .66 836 .92 672 .97 9061.03 •8111.08 9771.13 1011 1.171043 1 10761.271106 1,31 111361 3000 4x641.17 1 9481 1 ' 1 • .4 104 4710731.8 •11041.6711341.83 11631.68 3300 1.54 9941.60102=1.671061 1.73 10111 1. 601111 1.8711361.931167 1.99 1195 2.06 12 1 -- 3800 0481.98 1075 2.08 1101 2.12 1126 2.201153 2.27 1181 2.34 1201 2AZ 1234 2.44 1290 266 2 HP Ownhdd Mote, St thorns Table 11 Standard Motor And Sheave/Fin Speed (Rpm) Table 12 Oversize Motor And Sheave /Fan Speed (Rpm) Table 14 Gas Find Heating Capacities Nom 1. Sseana sups is Iota Mang capacity. Second 9oepetFYat Mug.. cFM Ruse' Table 13 Static Pressure Drops Through Accessories (Inches Water Column) O.Y In closes prnsre drop due to Ants end Mr col pen mar heel PAN e 113 s fen etp Time's Wary ugorod nesti h oonwnerdd wawa R en M.lM pumas Ward, 143ec30 des+enid nJ Wood to tomes tea** and rorlkturgar M se, asYopoa sandbar.. Using the surf♦ hempars tents of or ten meters a Mown M our nebular dui will net maul to nuir+rnu tipping a WNW" mow ilium Our produa•s wenwtty .41 n et W 6 Turns 4 Turns 3 Turns 2 Turns 1 Tum Open Open Open Opal Opal posed 722 791 860 92.9 998 1066 5 Turns 4 Turns 3 Turn 2 Turns 1 Tom OPen Open Open Open 064x1 Ciofed 990 1048 1108 1164 1222 1280 Economiser with OAhiA Oatrgerat 100% OA 100% RA 2400 0.06 012 0.02 3000 0.10 0.15 0.03 3600 0.15 0.20 0.03 NOM 1. 1•nsnr L CA.Ousfde AM; RA.RM + nAir Ak Temperature • Una • Model No. Heating input MOh Heating Output MBh Rive Rang. YC00906.1. 12,000 97.000 2540 YCao90C•4' 205.000/150400 166,000/122.000 36.65 X 013 .09/23/98 WED 08:53 FAX 206 / 928 2095 GENSCO /TRANE General Units shall be dedicated downflow airflow. Operating range shall be between 115 F and 0 F cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with DOE and/or ARI testing procedures, All units shall be factory assembled, internally wired, fully charged with R -22 and 100 percent run - tested before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified In accordance to ANSIZ21.47 for gas fired central furnaces and UL 1995/ CAN/CSA No, 236 -M90 for central cooling air conditioners. Canadian units shall be GSA certified, Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized and finished with a weather - resistant baked enamel finish. Unit's surface shall be tested 500 hours in a salt spray test in compliance with ASTM 8117, Cabinet construction shall allow for all mainte- nance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing only a single fastener while providing a water and air tight seal. The base pan shall have no penetra- tions within the perimeter of the curb other than the raised We high supply/ return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. Unit•Top The top cover shall be one piece or where seams exist, it shall be double hemmed and gasket sealed to prevent water leakage. Filters One inch, throwaway fitters shall be standard. Mechanical Specifications Compressors All units shall be direct- drive her- metic, reciprocating type comp- ressor(s) with centrifugal oil pump providing positive lubrication to moving parts. Motor shall be suction gas - cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Crankcase heater, internal tempera- ture and current - sensitive motor overloads shall be included for maximum protection. Shall have internal spring isolation and sound muffling to minimize vibration trans - mission and noise. Low pressure switches shall be standard. Refrigerant Circuits Each refrigerant circuit shall have Independent fixed orifice expansion devices, service pressure ports and refrigerant line filter driers factory Installed as standard. An area shall be provided for replacement suction line driers. Evaporator And Condenser Coils Internally finned 3/8' copper tubes mechanically bonded to configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure pressure integrity. The evaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 pstg. Gas Heating Section The heating section shall have.a drum and tube heat exchanger design using corrosion resistant steel components. A forced combustion blower shall supply premixed fuel to a single burner Ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative pressure gas valve shall be used that requires blower operation to initiate gas flow, On an initial call for heat, the combustion blower shall purge the heat exchanger 45 seconds before Ignition. After three unsuccessful Ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. 6 Units shall be suitable for use with natural gas or propane (field installed kit) and also comply with California requirements for low NOx emissions. Outdoor Fans The outdoor fans shall be direct- drive, statically and dynamically balanced, draw through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and have built -in thermal overload protection. Indoor Fan Units shall have belt diiven, FC centrifu- gal fans with adjustable motor sheaves. NI motors shall be thermally protected. Oversized motors shall bo available for high static operations. Units shall be capable of providing t` ESP at nominal unit CFM (400 CFM/Ton). Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Units shall provide an external location for mounting fused disconnect device. Micro- processor controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling and/or ventilating decisions in response to electronic signals from sensors measuring Indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point and provides better building comfort A centralized Micro- processor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. Accessories Roof Curb - Downflow — The roof curb shall be designed to mate with the downflow unit and provide support and a watertight installation when installed properly. The roof curb design shall allow field - fabricated rectangular supply /return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall ship knocked down for field assembly and include wood nailer strips. 2013 09/23/98 WED 08:54 FAX 206$ 2095 GENSCO /TRANE Mechanical Specifications Economizer - Downflow --- This accessory shall be either field or factory Installed. The assembly includes — fully modulating 0-100 percent motor and dampers, baro- metric relief, minimum position setting, preset linkage, wiring harness with plug and fixed dry bulb control. Solid state enthalpy and differential enthalpy control shall be a factory- supplied, field - installed accessory The factory- installed economizer arrives In the shipping position and shall be moved to the operating position by the installing contractor. Remote Potentiometer — The minimum position settinc) of econo- mizer shall be adjusted with this accessory. Powered Exhaust --The powered exhaust shall assist the barometric relief damper in the economizer in relieving building pressurization. Motorized Outside Air Dampers — Manually set outdoor air dampers shall provide up to 50 percent outside air. Once set, outdoor air dampers shall open to set position when Indoor fan starts. The damper shall close to the full closed posiition when Indoor fan shuts down. Manual Outside Air Damper— Field installed rain hood and screen shall provide up to 25% outside air. Oversized Motors — Field or factory Installed oversized motors shall be available for high static applications. Coll Guards -- Coll guards shall be field - installed for condenser coil protection. Control Options Trane Communication interface (TCI) — Shall be provided to interface with the Trane Integrated ComfortTMI systems. Zone Sensors —Shall be provided to interface with the Micro equipped Voyagers and shall be available In either manual, automatic program- mable with night setback, with system malfunction lights or remote sensor options. / 4 . O Input / Output Expansion Accessory — This kit allows Integrated Comfort"' Sytems to read Supply Air Temperature, Return Air Temperature, Return Air Humidity, and direct indication of fan failure without the use of an economizer or motorized outside air accessory. Electronic Time Clock — This field Installed accessory kit wil allow the unit to operate in the unoccupied mode or perform night setup/setback functions utilizing a standard individual scheduling. Rot Conventional Thermostat Interface (CTI) -- This field - installed circuit board shall provide interface with electro- mechanical thermostats or automation systems. Differential Pressure Switches — This field installed option allows Individual fan failure and dirty filter indication. The fan failure switch will disable all unit functions and lash* the Service LED on the zone sensor. The ditty filter switch will light the Servioe LED on the zone sensor and will allow continued unit operation. 09/23/98 WED 08:55 FAX 206 9( 2095 GENSCO /TRANE MINE' • All dimensions are in Inches ,46 FILTER ACCESS DOOR HORIZONTAL ONLY • • DOVNF LOV CONDENSATE DRAIN CONNECTION 1.00 NPT LOV MEAT 1/2' NP GAS INLET HIGH HEAT 3/4' NPT GAS INLET 2 DIA. HOLE (UNIT CONTROL VIRE= aux N a.r RANCC ee Q.LA A C 62 �• ��a.r4war u Table 1 ..Unit Wiring Uni Model Nor,' YCO180e3, • Y00180e4 YCo1608W • 14 1/16' • NOTF3c 1. NMCFI bmaia• per NEC. SERVICE GAUGE , PORT ACCESS 1 I/2' PERIMETER CURS P1.4 c 7 7/16' 66 5/e' Electrical characteristics — Power Exhaust Accessory Table 2 Aoeerory Operating Model No. • Voltage Phase & Y VRXO10A ' 203.230 OAYPWW(020A 460 BAYPWRX021A 575 7!e' atA. HOLE • WRIT CONTROL VIRES) . sr Unfit Operating Vmlege Range • 187,2.53 414.606 . 517433 • YCD180- 50;207.09 1 13t18' 4111fr 2.Values do rot M•Uuda po..r ednust eeee..oy Table 3 Accessory Net Weights (Lbs) Economizer Outs der Ak Oampeq Oversize Roof Motor Nei/ Motorised Manual Curb ' Adder e5 60 32 205 5 Meg% -OW Mie4heri. 15 Ton Downflow Gas/ Electric Packaged Unit YCD180B NOTE: Duct flanges mount 7- 7/16" down inside the curb on the 1-1/2" curb flanges. See recommended duct dimensions on page 3. Weniram Ciro$ M1PY' Standerd/Oven;tted It2A19 37/40 , 30/32 HP 314 3/4 3/4 RPM 1040 1040 1040 e' LPG AA Conversion Zane Kit Solon 1 ' Maeknam Flue Size Or Madmen Cloak treidar Standard/Oversized 901100 45/50 35/40 Mips RA IAA SA 135 3.2 8.4 2.1 52 Power blamer 95 016 NOTES: 1. NA %W t atAdd 6. added le enk *an w4414 wM.n ordering hoary I,.aM.d monvoriger. 2. Foamy Ueaid egdaen 1.r e..n.,Lora wldolr raw ag.dgn 1.M. EER • .e7. Foe or riee p, wukLllraw tuerirtxEPAa. a3. 1TiY ried ino .mpiro.wiYn • RECEIVED erre OF TUKWMLA SEP 2 3 1998 PCRMI`T OI'»NTER 09/23/98 WED 08:56 FAX 206 1(7 2095 GENSCO/TRANE ; • ; • • • • . :" . , . • , • :" " !.• ^ • Gran Cooing Coodfr ' E • ER • • NimineICFM / ARt Flied „ AM Net Ceding Capacity infe8tated Pert Load yaw System Podeer (KW) • •,.' Table 4 General Data Outdoor Ce4 - Type • • Mph-Performance Tube Size (in) OD • . 375 Face Ares On ft, 24.18 Roos/FPI 2/16 Woe( Co & • WO* Honferlomenee Tube Ske (In.) . 375 . Noe Ame fel ft/ •• 17.50 Roves/FP1 • 2/15 Refrigerant Control Short Wks , Drain Connecdon No./Size On-) 1/1.00 NPT Outdoor Fen • Typo Na Used/Olarnetes (in.) • Orlye Type/No. Speeds CFM Na. 1.106X5/NP Motor RPM Indoor Fan • Type FC Centrifugal No. Used/Diameter (Io) 1/16 X 16 [him Type/No. Speeds Belt / I No. Moen% •• . , , . 1 Motor HP (StandardrOverstrart 3.0/5,0 Motor RPM (Standan2/.0yerstain4 1740/3450 Motor Frame S)iit (Sienderd/Oveielzedt 145T/145T Aims - Typo/Furnish ' ' (NW Size fimornmended liotsowent awn,* Os of R .• • 1..•• • Propeller 2/26 • •••• • Direet/1 . 10.400 ' • 2/J50'-n 1.100 • 't* • YCD18083,84,8WL. TC018083.84,11WN 183,000 8.6 . 6,000 15,300 172.000 8.90 20.00 fiantIng Parfetwerme • lies5'ng Models Low HO Healing input (13610 250.000 350,003 1st Stage Unas Only 176=0 250,020 Heedng Outsed (8tuh) 2000 03. 281,02o 1at Stage Urals Only • 142.000 223.00o AFUEV WI 60.1 Steady Slate Elficieniy (v. 81 81 No. Menne , . • . !*. • Na. Stages 2 Gas Connedion Pipe Slut (in.) :;•.44:" • - 112 214 ' • Compressor • ' No./Type • 2/Trene H Sound Rating (8ELS)* ' . .82 T)voweentY/Yell (2)20X20X 2 (4)20X 25 X 2 94/Okuit to= .1' • . 1. Cooling Pedornumatts rood et 16 F sodded, 110F ereetinp bulk ID F onetime* buts. Oroes rapacity does not includil * tow bn new hut Mt end* Is nal and iMnda ihe elk* ot ten mien hos. Units ma what* Oat oparsdon to a SO% ornemlne Molten in intentarvie Wet 5iintiltd 210. 2. WI Ii Med at AN1 =nations main outounce oleo COE me prneeduros. 3. Intesverd tlast toad Value Is Wart on Mt Sandell 21o. Units orn raid nt SO F maim, lo iondeino dry bulk ind 07 soloing mit bulb st AR mod db. ' 4. V461640 Podatnuftro En* warm sod nen eta woe matenhed and appeand under Wooster/ toot condliont tails A nNidon.l Undoes rendsres. /tains sham on Its SilroleOrd Up le LOCO feet Facetdvadou above 2.000 Net mince ibould tai teamed at be mat d4% bt 416/11.033 Ian above sea lent 5. AR JE and Straby Sate Elkkatcy an rued in monotanot MO DOE Wm procedure& 01. Saud Edina In turd it notordincs talb A F Itkondird 770. 7. Iltddiatoint *riga ts an nonntimet.voluo. rot a mon predate sus. on unit nuncios and menial onnedon two lib 017 " / 09/23/98 WED 08:56 FAS 206 9 2095 GENSCO/TRANE lip018 All dmensions are In inches • NOTE: Duct flanges mount 7- 7/16 down inside the curb on the 14 /2"' curb flanges. • Power Exhaust End Panel View PANEL ECONOMIZER STANDARD END PANSY. OF unrr ECONOMIZER END PANEL A FRESH mi (MAW1i 7 7/1 11 1/6'• CEfrrte C GRAVITY • WIDTH 0 CENTER OF GRAVITY 3 r ___, CENTER OF GRAVITY GTH 17 7/8' • ' 59 7/1 r -r te I .. I E I S 1 U p I R . . i 6111!16 •' Y 1 Table 5 Ma)dmum Weights, Corner Weights And Center Of Gravity Dimensions' n _ h — +� 22 - 4 I 1\2' PERIMETER CURB FLANGE CONDENSATE LOCATION r C 624/16 . 41/4 Madmum Woights Rtxl Coma Wcighs Rlx)t Center or Gravky (Ind Shipping Na A B C 0 length Width 1906 1538 535 387 259 357 45' 29' NOTES: I. Cornea wdaitan: given for Idonaadon only. Unk is to tat stopported contiewassly by a taktb or equivalent, kostat tumor*. 2. For corm wdghb unk locution too d+prun. Ai.Po.. f) 51, INC MSS INC MM. 1110 Mee DC MU 6110 44511 LIC MM PIG • MM MC MM SHC ag11 AC PAM INC 611h SIC 76 1713 t6(1 1108 IOU Tess eta t601133.6 130.3 .61.1 186$ us 1464 1253 166.6 82.6 1541 124 1266 1172 1613 NO 1717 the 1400 $0 171.3 1151 time 1311111.6 101 /60./ toes 1273 1111 e63 161.6146.0161111271 620 1116 1301 161.2 nu 1733 013 SL 172.4 172.4 1105 1601 111.6 1313 1664111.4 160.3 166! vela 12116 /6/31611 1611 1613 166.3 174.7 1402 1402 161.3 144.4 1713 124.6 10 17111 17111 186.1 1600 151.6 1610 1743 17413 16617 1776 177.7 1441 1111.0 150A 141.6 11110 111.6 146.2 1612 lies 1543 164.5 1712 1461 76 17131443111210121031 731 163312341110103111$ 161 1461 110.1 171.1 *70107.7 612 13114 122.5 1117 !2.0161.0 me sox so 1711 1732 1.IS 1373 2e2.e 100.6 1163 1167 1130 112.1 16(1 Ne 1535 112.4 171.1 127.1 1107 962 1364 1744 1667 1715 111.0 064 0.6 110.2 1112 1114 1844 7071 1361 1711 $734 MU 1033 1313 1342 1132 1131 171.1 1111 1107 1303 1.116 1466 1567 1541 181.0 1304 SO 111.1 10113 1132 1123 708.1 1671 1617 162.7 1161 1655 13(3 1666 1162 1151 1761 175.6 168.7 ,111.7 16411 1711 161.4 161.4 111.0 1424 75 1713 1461 1111 1120 206.4 746 1661 144,7 1861 107.2 1914 71.3 150.11 1361 173.11 100.4 192.3 17.6 1722 121$ 1573 P51 1116 6(/ 6100 0.0 1713 1713 114.1 1411 2044 1061 1710171.0 161:.1 137.7 1111.6 1011 1673 157.9173.113111123 555 141.2 141.2 157.3 1212 1115 631 06 1661 M155 194,1 1732 7064 141.7 1.0.0 150.0 1951 1661 108.1 131.0 1645 14012 1735 1013 1327 104A 161.4 151.6 160.5 110.6 1833 1350 90 1911 1115 1101 111 7064 1633 141 last 112.1 lets 1191 161.3 1720 172.0 161.7 III] 152.3 117.0 112 1024 167.1 117.1 117.5 1680 76 1715 1113 1117.0 1173 200; 71.3 1110 1113 1653 1111 2022 741 1511 1422 1711 1064 1153 7119 1142 1110 160.2 1.1 1163 101 7200 SO 1661 1111 1170 141.1200; 1113 1711 1711 156.3 1646 10112 166.1 1151 1741 1315 1162 1044 103 1463 110.2 134.1116.2 06 116.7 196.7 1670 1107 2016 141.7 1183 1111 1113 1715 2015 144$ 1773 1773 1711 171.7 1102 121.6 151.1 1611 144 1164 1612 141.7 90 2030 21110 2065 2003 2616 1714 11114 111.4 2011 2013 2021 1140104 11105 1001 1308 1912 1141 1704 9041743 176.3 1642 1611 09/23/98 WED 08:57 FAX 206 2095 GENSCO /TRA1E Table 6 Gross Cooling Capacities (MBM) Gem Or/ SI , M. .7 73 61 11 Arti ntTwro«.e• r. 73 • 61 • NOTES: 1. Al psd U.. Meru 51 erns and how no nrridr.d Indoa ten twa, To elr.da as 4eo w4trwl Indov tan MR 3 PASO. Total Goals Cap.* . • 3. SC • Sw1r1N INM 1Zapacyr Table 7 Electrical Characteristics - Evaporator Fan Motor - GO Cycle Standard Evaporator Fan Motor Amps Unit Model No. No. . Volts Phas. HP' FLA • :. LRA • No. Volts Phase HP FLA LRA .•:% YCD18084 1 460 3 3.00 4.8 40.5 1 460 3 , 5.00 7.8 54.9 YC01808W 1 575 3 3.00 • 3.9 ' 31.0 : • 1 ' 575 3 5.00 6.1 41.6 Table 8 Electrical Characteristics Compressor Motor And Condenser Motor -- 60 CO* Compr.nar moors Condonsor Fen Motors Uok mp . MPG' Model No. No. Vole • Phase Ku RPM RLA IRA • No. Phase HP RA WA YC018083 2 , 208 -230 3. 740 3450. 28.7 156 2 1 .60 3.2. 48 YCD18064 2 400 • . 3 • ' 7.60 3450 12.7 79 . . 2 • 1 30 1.6 3.8 • YC01808W 2 675 3 7.60 3460 10.2 . . 83 . 2 , 1 • .50 1.3 3.2 I. Arne Aro 4110..sn nroror; ntwdpl/ wtu. W riwr4wr el moues to domino sal am.a 2. Mr a 4.0.i com r l4er. . Table 9 Combustion Blower Motor Data Heating Amps Haat Stapes HP RPM' Volts Phase RA LRA Low 2 1/10 750012800 208.230 1 04 2.00 .High • . • Z 4/10 750012800 206.230 1 . 0.8 2.00 NOTE: 1. Nien / low Sped. 4 lOG 73 116 Oven@ed Evaporator Fm Motor 47 . . 73, Amin ra 019 09/23/98 WED 08:57 FAX 208 9( 2095 Table 10 4803 5200 5603 6000 8403 0300 7200 Evaporator Fan Performance GENSCO /TRANE .10 .20 .30 .40 .50 , , • .60 • . ,7p • RP PM M BHP RPM BHP R BHP PPM RIP RPM BHP RPM SW 1344 a Fluid Supplied Low Sa -- 584 1.22 613 1.33 847 1,49 591 1.41 623 1.53 849 1.811 633 1.73 651 topes 1.96 713 209 674 2101699 228 727 237 749 2.40 716 252 739 2.73 766 205 788 759 03 779 a22 804'9.30 827 347 900 3.s4 820 3.7 842 3.58 866 4.07 • ip ForSondrdEvor mwFen Sneed0W 1► MerweaTsOM11. • • • FaONIO Nlirspws ww e FWWIrslwTYM1 i ' Table 10 (Continued) • 1.43 1.50 04.4 RPM . 131-P RPM BHP 1. r non a•andwd. LOA • Outside Ai ide r and 11A. Return Ale 1.00 1.10 1.20 1.30 RPM MP RPM BHP RPM 81P RPM BHP RPM 01.4 RPM dive (1) 3 HP Mended Motor with 8%11 daMd Dflve 675 1.99 704 1.71. 732 1.84 759 1.98 765 811 2.28 679 1.73 709 1.90 736 204 762 2.17 788 2.31 831 2.46 837 2.62 742 2.29 769 2.43 793 2.55 817 2.69 842 2.84 865 3.00 775 2.66 692 2.86 826 300 849 113 872 129 894 1441 9 6 3 6 938 3.78 919 10e 635 3.301 860 350 692 195 933 3.79 925 3.94 8 3 847 3.58 116 892 4.01 915 4.21••936 4.37 957 4.52 665 4.17 904 432 925 454 948 4.81, 970 501 900 5.17 S HP Oveeds tor Mo & Mtn • ( 3 HP Standard Motor 6 High Static Drift melt `Aco4ssory • Te t body sa11pled wows. In commercial anuianaerat ere dard s 8y de poets 1peeirr signed and lasted b aware reliably era c.xemo s*sur d[oellicne. Using tiedtempc. f imps d our mans a fen ma Maven an our bbrAsr dab rat 110I neap N twlrmi 'rotor roe (MOM • 3.15 inn efw. Oala inaluen pressNS0, Due P Wet Cole end PMi. . I. Fekl SuppOws Fin Snaeee BK105 nep,r+red• Feb SuppbO eel Into be necessary.• 2. SHP OM wu rslaMa5 ROOSkOi8.dMo 98 rsim1VP5OP.gthed.. ,;:t. • ,.. .! • ,. pnnimum=W Fs. Or products wrantywe rot b, enacted. Feb Ball (NI Ball b neaeseery. . • 3'--c • • • High SaMc 4800 812 277.937 293 .s200 5e03 .954.3.64 976 3.79 6000. 900 413 .1001 4.31 6403 1007 4.66 1027 4.65 6803 1036 5.22 1055 5. MACS 42 1.00 1.70 1.80 R PM BHbe RPM BHP RPM BHP 836 238 862 2.51 • 887 284 861 276 885 2. � �� 888 3.17 1 1 3.61 3.7 969 3.96 946 4.10 967 4.213 987 447 977 167 997 4.64 1017 5.013 1009 5.33 1028 5.49 1047 5.67 1.90 2.03 RPM BHP RPM 1311P 1311P 5169 e Molar & Mee 1034 3.49 1057 3.65 1047 3.901 1070 4.06 1063 4.38 1085 454 1082 4.93 1103 509 1104 5.55 / - 5 lf' Ovora1a:o Motor a • Raw Supplied I' gll sort Drive (?� Tlable.11l Standard Motor And Sheave /Fan Speed (RPM) Mee Accessory 982 3.04 987 3.19 1011 3.34 932 3.18 985 331 978 3. 130 46 11002 3 1025 3.75 906 93 1020 408 1042 4.23 1021 446 1042 11321 1062 4.79 1047 5.03 099 5.21 1085 5.38 10 - 6 Turns • • 5Twns' '.• 4 Turns •. •. 3 Turns 2Tums Opct • • Open • r :•• • Open Open Open '679 • • • 721 • • • 764 i' • • 906 849 Fenny ut et 3 inns even. Table 12 ' Oversize Motor And Sheave/Pan Speed (RPM) 611arrn 5 Turns �, • 411urn Turns . 3Turns 2 Turns 1 Turn Open ' On °MI • • Own Opcn Oven 806' 956 907 957 1008 1058 Table 13Sandard,Mlat/i4•, H"gh Stag Drive Accessory (RPM) • • 'orUttts ' •• 5Tw11s•t' • ,4Tistrc• , • 3 non 2 Turns • ODeh • • • Oven • • • OPen . coon Open • 1100 . •• 849 f• ' • •' 991 • •• 934 976 Table .14 r Static Pressure Drops Through Accessories • -'' (Inches n water Column) • • ' .! t • Eo ncenke 0 .4th • r .,�i•• OMIA Dampers' CNN Rime ••.1001EOA 14 R4 4800 0.07 0.25 0.03 6000 011 033 • 004 7200 0.15 • 0.40 0.05 Table 15 Gas Fired Heating Capacities Unit Model No. Haling Input MBh YCD1808 -L' 260/176 Tool 908 . 350/250 NOTES: ; L Second Stile h lead trefreg eaparlly. &mom Stage 1 FMa1 Maps. 5 Roatlnp Output Meh 200/142 2841203 1Tur Ober Closed Gored N/A 1 Turn Open Closed 1019 N/A Ak Temperature Rise hangs 25.68 35-05 020 09/23/98 WED 08:58 FAX 206 0,(7 2095 GENSCO /TRANE Mechanical Specifications General, • Units shall be dedicated downflow airflow. Operating range shall be between 116T and OT cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with DOE and/or ARl testing procedures. All un shall be factory assembled. Internally wired fully charged.with R -22 and 100% run tested before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to ANS¢21.47 for gas fired central furnaces and Ut. 1996 /CAN /CSA No. 236 -M90 for • central cooling air conditioners. Canadian units shall bo CSA certified. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel Exterior surfaces shall be cleaned, phosphatized and finished with a• • weather-resistant baked enamel finish. Unit's surface shall be tested 500 hours In a salt spray test in compliance with ASTM 8117. Cabinet oonstnidion shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstaled by removing not more than three SCUMS on the unit while providing a water and air tight seal All exposed %%ideal panels and top covers in the Indoor air section shall be insulated'with fire-resistant, pemnanant, odorless glass fiber rriaterlaL The base of the downdow unit is insulated with a toil - faced, closed-cell material. The downflow units base pan shall have no penetrations within the perimeter. of the curb other than the raised We high supply /rotum,openings. provide an added water integrity precaution should the condensate drain back up. The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one place or where seams exist, it shall be double hemmed and gasket sealed to prevent water leakage. Filters Two inch filters shall be factory supplied, Compressors Compressors shall be direct drive hermetic, reciprocating type with e O centrifugal oil pump providing positive lubrication to moving parts. Motor shall be suction gas-cooled and shall have a voltage utilaatitir( range of plus or ' . • : minus 10 percent of unit nameplate voltage. Crankcase heater, internal tem- perature and axrent- sensitive motor overloads shall be included for maximum protection. Shall have Internal spring isolation and sound muffling to n* imlze vibration transmission and noise. External high pressure cutout shat be provided. Low pressure switches shall be standard. Refrigerant Circuits Each refrigerant circuit shall have independent fixed orfice expansion devices, service pressure pons and refrigerant fine filter driers factory installed as standard. An area shall be provided for replacement suction line driers. • , Evaporator And Condenser Cofts Internally finned W' copper tubes mechanically bonded to configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure pressure integrity. The evaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 prig. Gas Heating Section The heating section shall have a drum and tube hest exchanger design using corrosion resistant steel components. A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliabie operation, a negative pressure gas valve shall be used that requires blower operation to initiate gas flow. On an initial call for heat, the combustion blower shall purge the heat exchanger 45 seconds before ignition. Alta' three unsumasssful ignition attempts, the entire heating system shall lie locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane (field installed kit) end also comply with California requirements for low NOx emissions. Unit shall have two stage heating. Outdoor Fans The outdoor fans shell be direct drive, statically and dynamically balanced, draw through in the vertical discharge position. The fan motors) shall be permanently lubricated and have built - in thermal overload protection. qb 021 ) 09/23/98 WED 08:59 FAX 206 r 2095 GENSCO /TRANE Indoor Fan Unit shall have belt driven. FC • centrifugal fans with adjustable motor sheaves. Unit shall have an adjustable idler -arm assembly for quick- adjustment to fan belts and motor sheaves. M motors shah be thernwiy protected. Oversized motors'will be available for high static operations. Standard units shall be capable of providing 1 ESP et nominal unit dm (400 dm/ton). ' Controls — Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal black for power wiring. Units shall • provide an calomel location for • mourning fused disconnect device. Micro- processor oontrds shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating. • cooling and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature. control, rninimizes drift from set point and provides better building Comfort, A centralized Micro- processor shah • provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection: Accessories • Roof Cutb — The roof curb shall be designed to mate with the downf ow 'unit and provide support and a watertight installation when Installed property. The root sub design shall allow field-fabricated rectanediter supply/return ductwork to be connected directly to the curb. Curb design shah comply with NRCA' . requirements Curb shall ship knocked down for field assembly and include wood nailer scrips. Economizer — This aocessory shall be either field or faaory.instatfed. The assembly includes — fully modulating . 4.100% motor and dampers, barometric relief, minimum position setting, preset linkage, wiring harness Mechanical Specifications with plug and fixed dry bulb control Solid state enthalpy and differential' enthalpy control shall be a factory- supplied, field-installed accessory. The factory-installed economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Remote Potentiometer — The minimum position sewing of economizer shall be adjusted with this accessory. Powered Exhaust — The powered exhaust for units shaft assist the . barometric relief damper In the economizer in relieving building pressure. Motorized Outside Air Dampers — Manually set outdoor at dampers shall provide up to 50 percent outside air. Once set, outdoor air dampers shall open to set position when indoor fan starts. The damper shall dose to the full dosed position when indoor fan shuts down. Manual Outside Air Damper — Field installed rain hood and screen shag provide up to 25% outside Oversized Motors — Reid or factory installed orversized motors .ahat be avaitabto for high static applications. CORDOIOptions . Trans Communication Interface (TCI) Shall be provided to interims with the Trane Integrated Comfort"' System. Zone Sensors — Shan be provided to, interface with the Micro equipped Voyagers and shell be available in either • manual, automatic programmable with night setback. with system malfunction lights or remote sensor options. Conventional Thermostat Interface (CTI) -This field installed circuit board shall provide interface with electro- mechanical thermostats or automation systems. 7 i • Differential Pressure Switches -- ThIs bald Installed option allows Individual fan failure and dirty filler indication. Tha tan failure awhch w@ disable all unit functions and `flash' the Service LED on the zone sensor. The dirty filter switch will tight the Service LED on the zone sensor and will allow continued unit operation. Input / Output Expansion Accessory — This kit allows Integrated Comfort"' Sytems to read Supply Air Temperature, Return Alr Temperature, Return Air NumkRty, and direct indication of tan failure without the use of an economizer et* motorized outside ait accessory. Electronic Time Clock —This field installed accessory allows up to 4 units night set -back and unoccupied functions when using a standard (Dual Setpotnt) zone sensor module. a 022 July 29, 1999 Shannon Buckingham 22043 — 68 Avenue S Kent, WA 98032 RE: Permit Status M98 -0182 1070 Southcenter Mall Dear Ms. Buckingham: r- City of Tukwila Department of Community Development Steve Lancaster, Director In reviewing our current permit files, it appears that your permit for the installation six (6) HVAC roof -top units issued on October 29, 1998 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Brenda Holt Permit Coordinator Xc: Permit File No. M98 -0182 Duane Griffin, Building Official John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 Dear Sir: City of Tukwila Fire Department Fire Department Review Control # M98-0182 Thomas P. Keefe, Fire Chief Re: H. V.A. C . at Gene Juarez Salon and Spec - 1070 Southcenter Mall The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated.at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required'. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic 'shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 2. Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) 3. In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide. notification of fire at that location. (NFPA 1 -5.6) The installation of wiring and equipment shall be in John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone. (206) 5754404 • Far (206) 575-4439 Page number 2 accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 4. When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall ' be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 5. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, C City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief The Tukwila Fire Prevention Bureau cc: TFD file ncd (5 /2) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575.4404 • Fax (206) 57544139 :'` .; co 4 cn in Fi al m 4 1-1 1-1 po....,....., oa • c:, ,-1 M . ------- A N mr I-i rzl w o o 0 H I ,. 0 H C.1 : OM c Er- 0 /.4. 1--iin E ,1 . r - i -l q C: i f;, L c?. _:,-- Z EJ cn r-4 i-.1 A RI co A H cp rzi . • H M Cr1 _z 41 E itl 4 El 0 r9 co r4 t.) to 4 t--1 En -: -4 41 CD Z :% o fri r4c::. 41 o ' u 44 z cl rzl r4 o • UPI PINX ABBREVIATIONS BUILDING CODE INFORMATION & And 4. Angie HORIZ. Horizontal ( At INSUL. Insulation < Centerline MFR. Manufacturer ti Round MAX. Maximum • Plate MECH. Mechanical Square feet MIN. Minimum ACOUST. Acoustical MISC. Miscellaneous ALUM. Aluminum N/A Not Applicable APPROX. Approximate N.I.C. Not in Contract ARCH. Architectural N.T.S. Not to Scale BLDG. Building NO. Number CLR Clear O.C. On Center CLG Ceiling P.LAM. Plastic Laminate COL. Column R= Radius CONC. Concrete REINF. Reinforcing C.J. Control Joint REDD. Required CMU Conc. Masonry Unit R.O. Rough Opening CONT. Continuous SIM. Similar DEPT. Department SPEC. Specifications DIA. Diameter SO. Square DWG. Drawing S.S. Stoinlesss Steel EA. Each STD. Standard ELEC. Electrical STRUCT. Structural EL. Elevation TEL. Telephone E0. Equal T &G Tongue and Groove EQUIP. Equipment TYP. Typical FT. Feet UL Underwriters Lab. F.T. Fire Treated U.N.O. Unless Noted Otherwise F.E.C. Fire Extinguisher Cab. V.I.F. Verify in Field . D. Floor Drain W.C. Water Closet FT Foot, W/ With FTG... Footing W/O ''Without GAL /. Galvanized GYP. BD. Gypsum Wallboard HT. Height N.M. Hollow Metal SYMBOLS MATERIAL INDICATIONS I/) 1111A Vilan %REFS: SP -I, BRDR2234 PLOT DATE 9/14/98 DIRECTION VIEWED SECTION IDENTIFICATION. SHEET WHERE SECTION IS DRAWN BUILDING SECTION DETAIL IDENTIFICATION SHEET WHERE SECTION IS DRAWN DIRECTION VIEWED INTERIOR ELEVATION SHEET WHERE SECTION IS DRAWN REVISION NUMBER WOOD BLK'G OR SHIM WOOD CONTINUOUS PLYWOOD MDF. FINISHED WOOD INSULATION BATT INSULATION RIGID FIRESAFING STEEL %/% —� SHEET METAL r --- j HOLLOW METAL CMU ALUMINUM GYPSUM BOARD GLAZING CARPET ACOUSTICAL CEILING PANEL ZONING PCB TOTAL T.I. AREA 8,975 SF BUILDING HEIGHT 1 STORY OCCUPANCY GROUP B CONSTRUCTION TYPE II —N FIRE PROTECTION APPLICABLE CODES 1997 Edition 1997 Edition 1997 Edition` 1997 Edition Latest Edition 1997 AUTOMATIC SPRINKLER SYSTEM PROVIDED 'DRINKING ESTABLISHMENT •• DIVIDED INTO TWO SEPARATE OCCUPANCIES LESS THAN 5,000 SF No building will be occupied, by people or merchandise, prior to approval and inspection by Fire and Building Dept.'s. Adequate addressing is required. Fire Dept. will assign all _ new addresses. Number sizes will be determined by setback of building from roadway. Four inch numbers are minimum. Numbers will be in color which contrasts to background. Designated Fire Lanes may be required for fire and emergency access. This requirement may be established at the time of occupancy and /or after the facility is in operation. OCCUPANCY CALCULATION UBC CHAPTER 10 TOTAL T.I. AREA Special installations of fixed extinguisher systems, fire alarm systems, dust collectors, fuel storage, etc. require separate plans and permits. Plans to be submitted to the Fire Marshal prior to start of installation. Portable fire extinguishers will be required in finished buildings per NFPA #10. ALLOWABLE OCCUPANCY 30 SF / PERSON ACTUAL OCCUPANT LOAD REQUIRED EXITS REQUIRED EXIT WIDTH Uniform Building Code (UBC) Uniform Plumbing Code (UPC) Uniform Mechanical Code (UMC) Uniform Fire Code (UFC) National Fire Codes (NEC NFPA) Washington State Energy Code Chapter 13: Section1320— Prescriptive Building Envelope Option Table 13 -1: Building Envelope Requirements for Climate Zone 1 1997 National !IElectric Code (NFPA 70) WAC 296 -46 Safety Standards NFPA 101 Life Safety Codei Americans with Disabilities Act Latest Edition Washington State Regulations for Barrier Free LAVATORIES PROVIDED Facilities or Design ( State' Amendment' replaces UBC Chapter 11 in its l entirety). 1 FEMALE OCCUPANCY Edition Washington Industrial Safety and Health Act REQUIRED FIXTURES Chap 296 -24 WAC, Chap 296-155 WAC; REQUIRED ',LAVATORIES Chap 296 -62, WAC FIXTURES PROVIDED LAVATORIES PROVIDED Special Inspections Structural Steel Reinforcing Structural Welding Special Inspections by Otto Rosneau Permits from other agencies Electrical Permits and Inspections Plumbing Permits and Inspections Public Pools/ Spas and food service facilities Fire Protection system Environmental Issues There are no sensitive area concerns associated with this project. Fire Department— Construction Information Automatic fire sprinklers, audible and visual devices, and a 'minimum of one pull station per floor are required for this project. Sprinkler system and fire alarm shall comply with NFDA #13, #72, and ADA requirements. Sprinkler plans shall be submitted to'Wastiington State Surveying and Rating Bureau, Factory Mutual or Industrial Risk Insurers for approval prior, to being submitted to Tukwila Fire 10,rshall for approval. The fire alarm plans are to be submitted! directly to the Tukwila Fire Marshal for approval. Submit three (3) sets of drawings. Special Fire Dept. permits are required for such things as: storage of compressed gas, cryogens, dry cleaning plans, repair garages, places of assembly, storage of hazardous materials, flammable or combustible liquids or solids, LPG, welding and cutting operations, spray painting, etc. Signage Building Identification signs— Displays Individual businesses in a planned shopping center(mall) shall be limited to wall mounted signs. The ,total allowed signage for any, building face shall be equal to 6% of the exposed building face area on which the signs are to be placed, up to a maximum of 500 square feet. Each business is permitteed a maximum of four signs with not more than one sign for any particular business allowed on any one exposed building face. No one sign shall contain more than 50% of the allowable sign area, unless approved as a type 2 decision. Applicants for sign permits will be required to document the area of the exposed building faceon which the sign is to be placed, total allowed sign area for that face, area of any existing signs, and area of the proposed sign. FIXTURE CALCULATION UBC CHAPTER 9 TOTAL GROUP B AREA TOTAL GROUP B OCCUPANCY 200 SF / PERSON MALE OCCUPANCY 23 ,REQUIRED FIXTURES REQUIRED L'IAVATORIES FIXTURES PROVIDED 2 2 2 3 23' 2 10,875 SF 299 160 +/- 2 32 INCHES 9,875 SF KEY PLAN N.T.S. PROJECT INFORMATION PROJECT LOCATION SOUTHCENTER MALL TUKWILA, WA TENANT GENE JUAREZ SALONS & SPAS 1661 EAST OLIVE WAY SEATTLE, WA 98102 206 - 323 -7773 ARCHITECT SELKIRK ARCHITECTS 118 N. 35TH ST., SUITE 205 SEATTLE, WA 98103 206 - 634 -0177 INTERIOR DESIGN JUDY DAVISON 1155 19TH AVE. EAST SEATTLE, WA 98112 206 - 323 -3354 45.0 STRUCTURAL ENGINEERING PETERSON STREHLE MARTINSON, INC. 820 JOHN STREET 'SEATTLE, WA 98109 206 -622 -4580 GENERAL CONTRACTOR CONSTRUCTION INC. 123— 4TH AVE. NORTH, 'SUITE 1 SEATTLE, WA 98020 206- 774 -4185 ARCHITECTURAL CONSULTANT MARK VON WALTER ASSOCIATES 1916 PIKE! PLACE LOFT 221 SEATTLE, WA 98101 253- 728 -8807 E R )ASNIN a 6 00BIN5 I e65 � n.di " �- Q 6 LtAER .0 e1 SEAIR,E ONIC'. i[AN SNOP 1 AY -BCC TOTS 97 SO['IW ETC. 9767 8ELKIRKARCHITECTS - t6d0,44W_ 'IAfI/It No .15.]9.66 REGISTERED ARCHIT CT FOR E H, SELKIRK STATE OF WASHINGTON ,IARACIER CUR ER LIST OF DRAWINGS ARCHITECTURAL A101 GENERAL NOTES AND SITE PLAN - -- KEY SITE PLAN A102 TECHNICAL SPECIFICATIONS A103 DOOR SCHEDULE/ PARTITION TYPES/ - - -- FINISH SCHEDULE A201 FLOOR CONSTRUCTION PLAN A202 ENLARGED PLANS A211 FINISH PLAN A221 FURNITURE PLAN A231 REFLECTED CEILING CONSTRUCTION PLAN A232 VAULT PLAN A301 BUILDING SECTIONS/ TYP. DETAILS A302 ELEVATIONS/ WALL SECTIONS ELECTRICAL - -- BIDDER DESIGN M - -- BIDDER DESIGN FIRE PROTECTION - -- BIDDER DESIGN RANGE �_ i 0 1 TENANT PLAN N rs. - - - - -- SEPARATE PERMIT REQUIRED FOR: 0 MECHANICAL aELECTRICAL 0 �,// PLUMBING 11�GAS PIPING CITY OF TUKWILA BUILDING 'DIVISION JCPENNEY THREE LEVELS •w1.µ n6M AREA - 196.551,1 FILE COPY ^:a Plan Chock oppn. and omissions and ar, '?'1. not authorial I *Won et . uriadsdods or al (fit ef con: G ENE JUAREZ SALON & SPA GP OF TUKWILA APPROVED OCT 27'1998 Aa NUI1I) �SU1LI7"tIG )1 SOUTHCENTER TUKWILA WASHINGTON 6635 Mq8-0182- R8'°`� A101 SHEET TITLE GENERAL NOTES / KEY PLAN RECEIVED CITY OF TUKWILA SEE 2 3 1998 PHASE PERMIT SUBMITTAL DATE SEPTEMBER 14, 1998 REVISIONS .118 North 3514 Street. Suke 205 Seattle. Washington 00103 Tat: 200634.0177 Far: 200634 4107 PERMIT CENTER SHEET NO. xRCFS: SCI- ?.DPDP ? ?34 PLOT DATE 9/8/98 TEIURNISHED'CND HAND TROWELED, 'EXTERIOR PLASTER,' FLAME STONE GLASS 9NISHED 000010 00000 I:]I:JCI❑ j 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 6 000011 . . 00000 00000 0 I:J CJ 010 0000x.1 WOOD AND GLASS 00000 ENTRY DOOR moot] 0 0000 00000 00000 00]000 00000 . 00000 13011110. 00000 00000 L ..i ! I ! 1 1. 1 1 1 br{ AHANNELILER I I L. I t WI NE SIG�1 1 $ I I'•i I 1 i 1 I I CODCEAL'EDIRACEWAYI .`. f . 1,`O ' _ I I ! 111 TTE!_II. f1II" I I I I I 11.I ' I I : ! I: I I I � I � ! I ', ' I L'I 1 I.1 ! ! 1if.l:_.I1,. I ! I I 2' -10" ® STOREFRONT ELEVATION v SCALE: 1/4" = 1' -0" 45 D . MAX 1 111P"W' TYP. PDF HANGERS VERT. STRUT 0 12 -0" EA'. WAY, 6 -0" MAX. FROM WALL #12 HANGER WIRE IN 12" DIA. EMT. 4 -#12 LAT. BRA SPLAY 0 90 DEC 5 DEG. MAX. F H IZ. EXIST. STRUCTURAL ASSEMBLY CONC. SLAB 0/ CORR. METAL DECK 0/ STEEL WEB JOISTS/ W- SECTION GIRDERS i .6! LIMIT 12 HANGER WRE'',TYP. RAISED CURD AT SKYLIGHT TRAPEZE AT DUCTWORK AND LARGE OBSTRUCTIONS _ MA 6 -0" MAX. SCALE 1" = 1 -0" 4• - 0.C. SUSPENDED CEILING - LATERAL BRACING MAIN RUNNERS AT 4 -0" ONE WAY CROSS RUNNERS Al OC ONE WAY 4' -0" 0.C. 12' -0" 0.C. EA. WAY 2' -0" SIGNAGE CALCULATION SIGNAGE'AREA: 35.25 SF STOREFRONT AREA: 2288 SF ALLOWABLE AREA (00): 137.28 SF CEILING NO INSTALL PE SUSPEND L WIRE SYSTE T: 9 UBC STANDARD 25 -2. GHT FIXTURES BY INDEPENDENT M 95 -4 TYP, CEILING ASSEMBLY 1/2" GWB 0/ SUSP. CEILING GRID 0/ STEEL HANGERS ATT/ TO STEEL WEB JOISTS /GIRDERS EXIST. EXT. SOFFIT RE- FINISH W/ LIGHTING RECESS LOW E INSUL SAFETY GLASS VERT. BUTT JOINT STONE FLOORING EXT. WALKWAY GASKETED REGLET 0 SLAB EXIST, 51RUCT. SLAB 0 10 -6" L CANOPY BACKSPAN WALL SECTION o STOREFRONT SCALE: 1/2" 1 13.0 FX BAR JOISTS OPEN C HANNEL LETTERS [ONCE LED1RACEWAY FOR NEON �-- EXTERI R PLASTER SYST BURNIS9ED FINISH CANT .ND FLASHING TO EXIST. CANOPY ROOF EXISTING' CANCn. B.O. EX. CANOPY CANTILEVER JOIST T.O. PARAPET B.O. CORR. DECKING M G ENE JUAREZ SALON & SPA SOUTHCENTER TUKWILA WASHINGTON & \ RE ARCHITECT 1 ARCHITECT GEORGE H. SELKIRK STATE OF WASHINGTON N\ O A302 0 SHEET TITLE BUILDING ELEVATIONS WALL SECTIONS .PHASE PERMIT SUBMITTAL RECEIVED CITY OF TUKWILA SIFF' 2 3 49798 PERMIT CENTER DATE SEPTEMBER 14, 1998 REVISIONS SELKIRK ARCHITECTS 118 North J6m &me. SYh 206 SwIW. 14raal** o 46103 Tot 200434-0177 68+:296-034-0167 SHEET NO.