Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M99-0004 - BOEING #13-01
M99 -0004 10000 E. Marginal Way So. Boeing #13 -01 City of Tukwila ( Permit No: M99 -0004 Type: B -MECH Category: NRES MECHANICAL PERMIT Address: 10000 EAST MARGINAL WY S Location: Parcel #: 000340 -0021 Contractor License No: HERMAC *217NT TENANT BOEING #13 -01 10000 EAST MARGINAL WY S, TUKWILA WA 98188 OWNER THE BOEING COMPANY PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 CONTRACTOR HERMANSON CORP. 1221 2ND AVENUE NORTH, KENT, WA 98032 CONTACT RANDY MEAD, 1221 2 AV N, KENT. WA 98032 PROVIDE- AND INSTALL 115 EACH SUPPLY DIFFUSERS, PROVIDE AND INSTALL 12 NEW RETURN AIR GRILLES, NEWDUCT'WORK AND AIR BALANCE. UMC Edition: 1997 Print Name: Valuation: Total Permit Fee: (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Status: ISSUED Issued: 01/28/1999 Expires: 07/27/1999 Phone: 206 575 -9700 Phone: 206 -575 -9700 ********************************************** * * * * * * * * * * * ** * * * * ** *•kk * * * * * ** Permit Description: 65.000.00 63.63 * * *** * * * * * ** * * ** *** k************'**.* ik****** * ***• * * * **** ** * * ** * ** * *k* * * **** Permit Center ju ho ^ized Signature Date I hereby certify that I. have read . examined this permit and know the same to ,be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction. or the performance of work. I am authorized to sign for and obtain this ilding p rmit. Signature: C�Ju� Date:.71p2 '9_ _ACUiraq.-...A4S4JA.._ This permit shall become null and void if..the:work is not commenced within 180 days from the date of issuance; .or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 10000 EAST MARGINAL WY S Permit No: M99-0004 Suite: Tenant: BOEING #13-01 Type: B Parcel #: 000340-0021 Status: ISSUED Appl ied: 01/08/1999 Issued: 01/28/1999 *** Perpri:t:Co6OittQnS: :. . 1. .No Olanges be made to the plans unless approved , .by'the :. . .- Architect Engineer and the„:,„Tuk..1.411,:a_Bulldipg DiviSton. 2i. :A 1 Pe rmits , insp ec t ton d plans shall. be a va il able at the j,ob to 'fli any cgn t ' s t ruc t ion . i The Se en ts .,are t cAb e .mai ri tafn:04.-:.antt avai I- : :a b 19 ,u n t 11 f ty04',.';4iiS p ec, t':,.tpil ' r Oa) 1 s gY'ant ' . . . • 3. A 1 1 1 "dtinstruct166 to ,b he ':'done 1 4 coil f 6 r.?fli a n CePiki:t li . 0.1 . 0).)y, e.d p l s and . 00u . i r emeiyis,,„gii:' t h e 0, R1 f o riii B 0 41 d to g 07:44 ; . , ;1, 97 . E di t i '8 i (. .!,,, ,1 44 , - l a Mend ki '',",,, UniforM ''IkC' h a 6' V&A 1 „ Code :,qif.§97, Eiti t' ) -, , and Wa s,141iig toi) State Energy.. Code.. ( 1997 EditIon)i r ,', 4. - Valid tt ''P er..t11 1 t. .:.., The J S'S,:ua`riOef„,of a per t r p l a il si`::'";,s p e,c i f i Oa t tons , an'il ,, t at), on s s ha 1 1' no t :he, con-.'.. , truerito,,Pbe a perm i t_'fOri - or an approval of. ally violation of Ofi.' of the prov i iOn of 'the._‘ ng code or'' ''''anY" 6 t h,0 r d'i'O'ii o p'. o f . t h0::,:j ur i sji - 6 t'l on, :, No permi t pre ;7, U. )11 6,9 • 'i*'',‘':, 9 i 1./il it 4.1 il / 4'.1 rs t Y to vi 61"&te - or: a n oe1 th e provisi ons l',.of e t.l.i,ts ,co deils ha '1''''b be ,: v al •st -:',:: - -'' --„ ) ' \. , ':,:..,....1 v f , .*-: - %: ,,,,,,... , ,, " 5. MA00 INSTALLATION INSTALLATION ilNsTptitTION.5„...ROUIRED ON TZ f001HE:...,4014(a L,y' ..,..,7:- ,.., _ . , , . , , ..::, 6. EleCtriCiGperiii,ts the Wn1pgt0) vi State OAVAsitin Of Labbe.', an(i..Indu.1 Oes an4 elecritiaiV • work', w i 11 be 'ins PeCt ed lb..4 thet,‘ 'icy- (248-6630) . " !•, •',';;1 " 7 .1 `,/ S • •'!,., e ' ' f ''. . : I ,, /. 1 . ri .. !) . . ,:••,,,•.:6'''' 0(d• !•,,,,,,,■''. • • ' fr' '.., -, ...,("(-t;," '••.. •i!,;' • . ,.....,s, .:1,.. „ . Project Name/Tenant. Description of work to be done: ) ) - 1 0 t_,4 c utiwac \' ■ l iS -- R C a I- > t� .0-- ; t `. Zci - ' . k--- ° ' \,l \1.) i \ \ , N. ..- IN() l.L lc' ' , Ci t: c' ,, \s . . 4 , . - -) L.l — T\ t l �'I LI � . Ci 4 ) L t C 1. NII-Cl Y CY \ . . ? ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition ❑ Fence Mechanical ❑ Manufactured Housing- Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems El Temporary Facilities El Tree Cutting Valtp of, Construction: Site Address: \C. (�(7?( C1.0t pity $Mate /Zip: )cti\ t /fln � _ ,re y ( Tax Parcel Numbe • 0000 —002-1 Phone: Property Owne ) ` Street Address: (-----1' 0 Sewer __, City State/Zip: <�)Cn Fax #: Contao'e I L Street Address: r * � � I� 4 ce '— f,� � 0 - / ,, City State /Zip: Fax #: Contractor: C. P ne: Street Address: I C. L.- ,1 ► , r City State /Zip: q ,t - Fax #: , ( c — S Ss- L iV) () Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax II: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done: ) ) - 1 0 t_,4 c utiwac \' ■ l iS -- R C a I- > t� .0-- ; t `. Zci - ' . k--- ° ' \,l \1.) i \ \ , N. ..- IN() l.L lc' ' , Ci t: c' ,, \s . . 4 , . - -) L.l — T\ t l �'I LI � . Ci 4 ) L t C 1. NII-Cl Y CY \ . . Will there be storage of fl /combustible haza material in the building? ❑ yes � :�, no Attach list of materials and storage location on so.arate 8 1/2 X 11 •a•erindicatin• •uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition ❑ Fence Mechanical ❑ Manufactured Housing- Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems El Temporary Facilities El Tree Cutting MONTHLY SERVICE BILLINGS; TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby c CITY OF TUKWILA Permit Ce1'i c, 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT:REQUEST.FOR MISCELLANEOUS PUBLIC WORKS PERMITS' ❑ Channelization /Striping ❑ Flood Control Zone El Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt It Size(s): El Water Meter /Permanent ## Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: El Miscellaneous ❑ Moving Oversized Load /Hauling WATER METER DEPOSIT /REFUND: BILLING: Name: Address: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accosted: MISCPMT.DOC 7/11/96 El Curb cut/Access /Sidewalk El Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing in Sanitary Side Sewer #: El Sewer Main Extension 0 Private 0 Public El Street Use El Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Date application expires: OR STAFF USE ONLY Project Nuinoer: Permit Number: 11--0o04. Phone: City /State /Zip: Application taken by: (initials) BUILDING OWNER OR AUTHORIZED A ENT: Signature ., : I %) ' Date: I �1 Print name: V t ti l � \� ` Ckline: 5-15' -9 - I OA NI. -5- c OY.)( ) �'t c Yl Address: f ■ t� 1 (i C C'ty /St f a � te//Zip: (t ,J/(. qktY 3,7 D WITH, THE FOLLOWING: ALL MISCELLANEOUS PE T APPLICATIONS MUST r E SUBM • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATL': DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER Y CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW ❑ Above Ground Tanks/Water Tanks - Supported directly .upon grade exceeding 5,000 gallons and a ratio of height to diameter width which exceeds 2:1: ❑ Antennas /Satellite Dishes ❑ Awnings /Canopies - . No.signage . ❑ Bulkhead /Dock ❑ .Commercial Reroof ❑ Demolition - )zk Fences - Over 6'feet in Height Land Altering/Grading /Preloads Loading Docks Mechanical (Residential & Commercial), ❑ . Miscellaneous Public Works ;Permits ❑ Manufactured Housing (RED INSIGNIA ONLY), ❑ ' Moving Oversized Load /Hauling ❑ Parking Lots ❑ Residential Reroof Exempt with following exception :• If roof structure to be repaired or replaced ❑ Retaining Walls - Over 4 feet in height ❑ Temporary Facilities Temporary Pedestrian" Protection/Exit 'Systems :,' Tree Cutting MISCPMT.DOC 7/11/96 Commercial Tenant Improvement , Permit Submit clieckiist is Submit checklist , No: M-9,, Submit'checkiist' Sub rriit :checklist' Submit checklist'' " No:: M -2.. ' Corpmercial5enant1Improvemen Permit. : :;Submit'checklist'Nai`H Submit`checklist > No M- Residentialconly. H -6 ;: H -1 Submit:checklist' No:,H =9 . Submit checklist No;: Submit.checklis't No M -5` Submit checklist No: M -4 Residential Building' Permit. Submit : checklist No: M-6:•:- SubmitchecklIst . _•No:; M -1 Submit checklists .. No; ; M -7 Submit checklist No: M =4`: Submit checklist . No: M72 Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent 'If the applicant is other than the owner, registered architect/englneer, pr contractor!IIansed'';:: by the State of Washington, a notarized letter from the property.owner authorizing the agent to submit, this permit application and: obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. *.k***A*+*4***+*+*^4*+* CITY OF TUKN%LA, .A 24.75 06/04/99 09:54 Payment Method: CHECK' Notation: H%VMAHBDN CORP. %nit:, Tl.B Permit No: M99~0004 Type: 8-M[CH MECHANICAL PERMIT 'Parcel No 000340-0021 Site Address: 10000 EAST MARGINAL WY S ' , Total FPs: 133 This Payment, 24.75 Total ALL Pmts: 133°63 Balance:, .80 *AkA+*n**«*k*+*+k+**A***+***Ah***++*«*A Account Code . Description Amount 000/323°100 ''' MECHANICAL - NONHES 24.75 TRANSMIT Number: R98000/7 Amount: 'TRANSMIT &���v��Y� � 7 � � ���Y 7 �� . -,1, . '`.` +^+**4*x+A+4«+«a*0+*++ * a *a �a***+^a�*fa* k a**A+ . ) � / CITY OFTU%NILA, NA \ �_� TRANSMIT ' \ '] +64+*a+4*x**+++*A*444*4*«**4+h°*+ +0+4v* ****A*A***+«6**A*+^a* , TRANSMIT. Number: R9880077 MM ount: 45.25 06/03/93 13:48 Payment Method: CHECK Natation: JAN%CE MASGEY %n1t: TLD •■■ -~^~---- -.'.~--_-~-~ ....... ._~,�~�~---~-~_~.4 Permit Na x M99-0004 Type: 0~MECH MECHANICAL PERM Parcel No: 000340-0021 Sit. :Address: 10000 EAST MARGINAL WY S Ttal as.: � 108.88 This Payment 45.25 Total ALL Smta: :. 108.88 ` : Dalun`e: °00 ' +4+*+*^***A**+a*+**+4**+a*+aa***a*+^*a*+**6+a*^****+* *4+***+*.** Account Code ' � Oeqcription Amount 000/345.830 PLAN .CHECK -`NOhkES 9.05 ' 000/322.100 MECHANICAL - NONNES '` 36^�Q �� *******A******A*AA******A**A* CITY OF THWILA WA 1RANSMIT *Ic*A**A********A***A**4"A*****************************14********** TRANSMIT. Number; R9100012 Amount: 63.63 01/28t9.9 . 12:46 Payment Method: CHECK Notation: HERMANSON CORP RL.H Permit No: M99-0004 Typo: n-mrcH MECHANICAL PERMIT Parcel No 000340-0021 Site Address: 10000 EAST MAROINAL NY S Total Fees: '63.63 This Payment 63.63 Total ALL Pmts: 63.63 Balance: .00 AAhAANN*A***Ah*R Account Code Beticription Amount 000/345.B30 PLAN CHECK - NONRES 000/322.100 MECHANICAL - NONRES 50.90 1.• • • 12.73 9060 02/01 TOTAL. Project' , /. — 0/ ?) Type of InspAction: Mach. 72,6,1 Address: / 0 clod e it-fa,,,- tl Dat called: Special inStructions: .- 31) D wanted: a.m. P. . Regrister: Phone: O& - 255 -2 (0.5'7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 0 proved per applicable codes. Corrections required prior to approval. COMMENTS: aL--r; ,e5t,Q $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be p at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: PERMIT NO. , (206)431-367 Project: 1eit) ( v ac 3 , wit ieL Type of Inspection: j Address: O Par / led: 1 z/ 9 Spe ial ctions: instr `I �,+J � � J`� f i ou P&`417 a - Del coil e wanted: /2 / a.m. p.m. Requester: rTN Phone: 6 — / c_2 to �� INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: INSPECTION RECORD Retain a copy with permit m - 'd—- - - L 54,e,/ - r. PERMIT NO. (206)431 2..„) frci-c b/.$ 5fie.e.0 „ 0 $47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Date :,ZM�� �7 0 COMMENTS: / J / - / J � -e- , j'1 g( A ' f " --ed T, �tf ef'Ins"pec�i r�: 7 ro(..9) C'... ?M , ,Se 4i'2. '"ice. .9 i vto (1 ,4 /, eac.) / ty 4, p-, 6-1 , ° .,,, 2i - J -?R.' .. Y N&rj , t y' .._ < i )73, o' /? 2.12 r G..4:0' // ..> 441.,'// � . . 5? / A 644'2'- 7 ze. ,. /€ 4 4 ./44 (0 7:47 � c2 / '7Q+f Xs1ri, .9.r -e r crTc.evz, F r cyz..).7L A Gl/ 4.4/1/ P , 7, D / T, �tf ef'Ins"pec�i r�: A . IlJ(1lJ t vto ) Date�calle ��JJan ]„ . Spec instructions: -^ q :30 'Date [�/ :1 1/1 +160e / e---9 1 7- Coo/0 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit PERMIT NCke''' (206)431 -3670 c recfi T q priar fo a oval, Date: , 7r rr ^ E $47.00 REINSPECTION F.E EQUIRED. Prior . to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pr1 l IIr+411(14A- "t JWC.- TYPe in p :ct o : j �'•'`-''`/ ess: !A Qt. r&D Till GL Da Iled/�� mo d'. " 1'" 1 1 s pec i al instructions: Date nted: 2-2)1 401001P p.m. Re s er: u?.. P Ci"1,Y( L 40 INSPECTION NO. A . roved per applicable codes. • lnspe INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 COMMENTS: ,A..e '2*' AM. PERMIT NO. mCoocA- (206)431 -3670 Corrections required prior to approval. 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pr ct: 5 e-1) 1S —a1 Type of In pectin HVAC- Address: PCoy V u Date ca leq!: q1 Special instructions: Date t sk cf wa fd: a (� i l m r` p.m. Re uester: Pho . .:y u -- Ho INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 COMMENTS: Inspector: proved per applicable codes. / Q1)-1 INSPECTION RECORD Retain a copy with permit Date: PERMIT NO. (206)431 -3670 Corrections required prior to approval. $47.00 REINSPECTI FEE REQUIRED. Prior to irlspection, fee rnust paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Ik Date: �3 •- rte.,_. *�G7�%- r- n..,,��� , . P ect: , 0 i /.3 - o ( T of Inso ction: A Su �C'.k INA r, VA C Address: /6006 E Jka r of D'ate /s /l' q Date a ted: C q �/7 / a.m. Special instructions: 4 p.m. Reque er: Phone: — COMMENTS: Inspector: 'INSPECTION RECORD ' • • Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 • Project: r Tytet I s e i 1[ 1,45,v _wc A/ d ress: era se) �'ct'i b<i.G,9>r- Date called: Special instructions: 4,/,l ' �� JJ Date wanted: a.m. p.m. Request Phone:. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 El Approved per applicable codes. corrections required prior to approval. COMMENTS: Inspec $47.00 REINSPECTION FEE REQUIRED. Prior to inspei ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: 00c)744,4-7X, /A. (.St)L 477 Oil. : INSPECTION RECORD Retain a copy with permit (/-'4 7 (F, / f) Date: PERMIT NO. w (206)431 -3670 Praiect: . eg.>eirt - 0 /3 / Type lnspectio : Address: /oda a i t u , , , , poi Date calledv (77 Special instructions: e y Date ■71.1 / M P.m. Requ e : lAA.4 Fea 7 i:_it. .31,, INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (\k(.. 60 b PERMIT NO. .*) (206)431-3670 Approved per applicable codes. Ei Corrections required prior to approval. $47. ElNSPECTION FIE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: oo . tct 4 k - 1..- ••••,, Receipt No: Date: ) ,,, .„ „ „ „T,7":.';,77,577,77,50;777.7,;_:,;,177.p7 T4,),:vfr Project Name Address Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM / Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued ?c /o c/ > - T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. 4 oa 0 Date Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) .57$4439 ITEM AHU RAF RE GAYLORD INDUSTRIES, INC. P.O. BOX 1149 • TUALATIN, OREGON 97062 -1149 USA (503)691 -2010 • FAX (503)692 -6048 • 1-800 -547 - 9696 '. .� . QTY 1 1 • ASTERISK DENOTES REVISION. ISO N N0.1.. EQUIPMENT SUBMITTAL PROJECT BOEING 13 -03 MEZZ. UPGRADE TUKWILLA, WASHINGTON REPRESENTED BY: NORBY COMPANY/ JIM PECHAN 3805 108TH AVE. NE BELLEVUE, WASHINGTON 98004 PHONE fil)828 -6636 FAX (206)828 -3982 CONTRACTOR: ENGINEER: GAYLORD SALES ENGINEER: SUBMITTED BY: REVISION DATE: JIM HARRINGTON KIM SIMONDS 11/2/98 TYPE OF EQUIPMENT CSU -22K Triple Deck Mulfizone CSU -12K 11\( COVON1 2 g V19 ON ySI de l IL" CO WORK ORDER NO. 8590601 8590602 submittal documents are prepared for review and approval by the purchaser and /or the design professional on the project. This submittal is for the purpose of indicating exactly the equipment Gaylord intends to furnish. The equipment submittal is based on the information provided to Gaylord by the solicitor of pricing. Frequently the information provided prior to bid does not include an entire set of contract documents. Gaylord shall not accept responsibility or liability for requirements appearing in documents or specifications not made available to us prior to the bid which are not included in our submittals. Gaylord's submittal document wholly represents what shall be provided upon approval by the purchaser and /or design professional. An apse reviewed submittal returned to Gaylord with a RELEASE FOR PRODUCTION shall be assumed to have been desFi[<BM gr Jai compliance with the bid documents and shall be manufactured in accordance with the GaylordGDt P KNIT R 01)cpcif SUPPLY FAN QTY: 1 CFM: 22,000 ARRG: 3 SHAFT: SOLID ALT: 0 FT SIZE: 27" ESP: 2.5" W.G. DISCHARGE: BHD SFT. O.D.: 2.4375" OPER TEMP: 70 ° F WD: DWDI TSP: 5.83" W.G. ROTATION: CW BRG TYPE: PILLOW BLOCK CLASS: II RPM: 1657 O.V. (FPM): 2916 BRG O.D.: 2.4375" BLADES: AF BHP: 27.07 DEFLECTION: 1.0" THRUST SPRING: ►I l YES • NO OPTIONS: ►X1 CLASS 2 MFR: 190100 MODEL: 270 VERSACON AF DWDI NOTES: SUPPLY FAN MOTOR HP: 30 MOTOR VOLT: 230V/460V FRAME: 286T EFFICIENCY: 93.6% RPM: 1775 OPER VOLT: 460V CONST: ODP (Premium Eff.) SHAFT DIA. 1.875" PHASE: 3 FREQ: 60Hz FLA: 37.0 MFR: 020018 MODEL: EM2535T SUPPLY FAN MOTOR BASE `! QTY: 1 MFR: 070070 MODEL: 286T Frame - Model# 2M515 SUPPLY FAN DRIVES DRIVER: 4TB74 X 1.875 (7.4) ►V FIXED • ADJ. DRIVER BUSHING: Q1 X 1.875 DRIVEN: 4TB80 X 2.4375 (8.0) DRIVEN BUSHING: 01 X 2.4375 MFR: 130015 RATE BHP: 45 HP NO. OF BELTS: 4 BELT TYPE: B ELECTRICAL SERVICE FOR MOTOR MAIN VOLTAGE: 460V /3Ph /60Hz . FULL LOAD AMPERAGE: 37 ® ALL WIRING BY OTHERS MIN CIRCUIT AMP.: 50 MAX FUSE SIZE: 70 MAX. BREAKER SIZE: 100 MODEL NO: CSU -22K QTY: 1 AR( Cb i(. BOEING 13 -03 S. MEZZ. TUKWILLA, WASHINGTON SUBMITTED BY: KES FILE NO. 98-5906 SALES ENG: JH DATE: 11/5/98 CSU ENGINEERING DATA DRY WT: 8471 LBS. 3 /5 (. i 10900 SW AVERY ST. TUALATIN, OR 97062 -1149 (503) 691.2010 REV /DATE/INIT WET WT: 8809 LBS. CITY OF T RECEIVED MAY 1 3 1999 PERMIT CENTER TAG NO, AHU WORK ORDER 8590601 SHEET NO: 1 OF 4 ELECTRICAL SERVICE FOR LIGHTS MAIN VOLTAGE: 120V/1 Ph /60Hz Ki WIRE LIGHTS TO SWITCH & J -BOX FULL LOAD AMPERAGE: .83 MAX FUSE SIZE:15 (1) 100W MARINE VAPORPROOF LIGHT NOTES: CASING ►.2 STANDARD - INDOOR GAUGE: 16 GA CABINET / 14 GA FLOOR MAT: GALV. A -60 ❑ WP1 - OUTDOOR FINISH: GRAY ENAMEL ROOF CURB: NONE • WP2 - OUTDOOR w /Curb Angle INSUL: 2" 3# DENSITY NOTES: 1. Fan access door requires Mechanical Latch (tool required for opening door). 2. Galvperf liner required throughout unit, with solid metal liner downstream of cooling coil. 3. Triple -deck Multizone damper provided by others - installed by Gaylord. COOLING COIL QTY: 2 CFM: 11,000 EDB: 80 ° F TUBE MAT: COPPER FIN HT: 30" ROWS: 6 EWB: 63 ° F TUBE THICK: .025" FIN LENGTH: 104" FPI: 10 LDB: 55.2 ° F FIN MAT: ALUMINUM FIN AREA: 21.67 FT` GPM: 76.6 LWB: 53.6 ° F FIN THICK: .01" FACE VEL: 508 FPM FEEDS: 30 EWT: 44 ° F FLANGE THICK: .75" APD: .77" W.G. PASSES: 4 LWT: 52.4 ° F BTU SENS: 298.6 MBH DRAIN SIZE: 1.25" CONN SIZE: 3" WPD: 4.39 FT. HEAD BTU TOTAL: 303.2 MBH Propylene Glycol: 30% CONN. LENGTH: 13" MFR: 030111 MODEL: BWL- 30X104- 6R- 10F -WR -(TYPE 5.30E- 4P) -3 "S &R NOTES: HEATING. COIL QTY: 1 CFM: 22000 EDB: 55 ° F TUBE MAT: COPPER FIN HT: 28.5" ROWS: 2 LDB: 104.2 ° F TUBE THICK: .025" FIN LENGTH: 104" FPI: 9 EWT: 190 ° F FIN MAT: ALUMINUM FIN AREA: 20.6 FT` GPM: 108.3 LWT: 167.8 ° F FIN THICK: .01" FACE VEL: 1069 FPM FEEDS: 19 WPD: 6.24 FT. HEAD FLANGE THICK: .75" APD: .81" W.G. PASSES: 2 BTU: 1167 MBH GLYCOL: 0% CONN SIZE: 3" RECEIVED CONN, LENGTH: 13" CITY OF TUKWILA MFR: 030111 MODEL: BWL- 28.5X104- 2R -9F -WR -(TYPE 5- 19F- 2P) -3 "S &R MAY 1 3 1999 NOTES: PRE FILTERS SETS: 1 FACE VEL: 344 FPM CLASS: II RACK: GAYLORD V -BANK FILTER GAUGE: DWYER 2001 EFF: 30 % SIDE ACCESS MFR: 060012 MODEL: 30/30 SIZE: (20) 20 "x20 "x2" (4) 16 "x20 "x2" NOTES: BOEING 13 -03 S. MEZZ. TUKWILLA, WASHINGTON SUBMITTED BY: KES FILE NO. 98-5906 SALES ENG: JH DATE: 11/5/98 CSU ENGINEERING DATA 10900 SW AVERY ST. TUALATIN, OR 97062 -1149 (503) 691-2010 REV /DATE/INIT TAG NO. AHU WORK ORDER 8590601 SHEET NO: 2 OF 4 ACCESS DOORS QTY: 1 OPTIONS: r NO HINGE ►4 LATCHES BOTH SIDES MFR: 030020 MODEL: HF20- 21.75 "W X 51 "H -EGO NOTES: 1. Outward opening, removable access door. ACCESS DOORS QTY: 1 OPTIONS: O. 12 X 12 DOUBLE PANE WIREGLASS VIEW WINDOW MFR: 030020 MODEL: HF20- 21.75 "W X 51 "H -EGO ACCESS DOORS QTY: 2 MFR: 030020 MODEL: HF20- 21.75 "W X 51 "H -EGO • SUBMITTED BY: KES FILE NO. 98 -5906 BOEING 13 -03 S. MEZZ. TUKWILLA, WASHINGTON SALES ENG: JH DATE: 11/5/98 GAYLORD 10900 SW AVERY ST. TUALATIN, OR 97062 -1149 (503) 691-2010 CSU ENGINEERING DATA n. nN�rwH :nrµ. REV /DATE/INIT TAG NO. AHU uaw..- •Mfe.s Cr, at s. ia.rv. iNV .roknM..t42iMlMothrlkkkoryt.µ RECEIVED CITY OF TUKWILA MAY 1 3 1999 PERMIT CENTER WORK ORDER 8590601 SHEET NO: 3 OF 4 • BarryBlower 11/02/1998 Project: Arch /Engr: Purchaser: LwA: 98 db FAN SELECTOR GUIDE Copyright 1984, 1992, 1994 FOR EXCLUSIVE USE OF GAYLORD INDUSTRIES Units English Wheel Width 100% Standard Selection Criteria Specified Fan Size BOEING BLDG. 13 -01 AHU Conditions: Standard Volume: 22,000 Static Pressure: 5.830 Alt. Above Sea Level: 0 Temperature: 70 Size 270 VersaCon AF DWDI Fan Construction Class II Inlet Vanes None Fan RPM 1,657 Brake HP @ Oper. Cond 27.07 HP including drive losses 28.29 Tip Speed 11,709 .075 lb/ftA3) CFM in.SP Ft. Deg. F. Version 4.5 Operating (.075 lb /ft ^3) 22,000 CFM 5.830 in.SP 0 Ft. 70 Deg. F. Mechanical Efficiency 81% Static Efficiency 74% Outlet Velocity 2,916 WRA2 If 1150 RPM Motor 222.8 WRA2 If 1750 RPM Motor 96.2 Wheel Mtl /Derate Std Steel /1.00 Point of Operation 64% WOV Wheel Diameter 27.000 IN Maximum RPM Class II 1911 Maximum RPM Class III 2409 SOUND DATA: Octave Band: -1- -2- -3- -4- -5- -6- -7- -8- VALUES INTERNAL TO INLET OR Sound Power: 103 95.100 94 91 89 86 79 OUTLET (REFER. TO 10^ -12 WATTS) dbA: 90 db © 3 feet (REFERENCED TO 10 " -12 PASCALS) CITY RECEIVED OF TUKWILA MAY 1 3 1999 PERMIT CENTER •. .. ... .... -. - . . t _ PROJECT: BOEING 14E1)6. 13 -01 . . . ....... TAG: AHU MODEL: 270 AF D4D4 • 20.0-:: OPER. CONDITIONS RPM 1657 BHP 27.07 CFM 22000 SP 5.83 ALT 0 TEMP 70 STD. CONDITIONS RPM 1657 BHP 27.07 CFM 22000 SP 5.83 • - • • . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . :: COLMAC COi1PRO III Sizing /Pricing System [Vers 3.22r] Size the coil with Target No. of rows: 6 Rep: Your Name Here Customer : NORBY Coil: BW - Chilled Water Tubes Stock: 5/8 x .025 Cu Pattern: 1.50 x 1.299 staggered Fluid: PROPYLENE GLYCOL %Wt: 30.00 % Fluid Flowrate [GPM] 76.6 GPM Fluid Temp Change [degF]: -- Entering Fluid Temp [degF] 44 F Max Fluid PD [ft H20] 8.4 ft H2O Finned Height (inches): 30 in. Finned Length (inches): 104 in. Material x Thickness: .01 Al Max Fin Spacing [FPI]: 10 Configuration: Waffle /Ripple Fouling Factor, inside: 0 Fouling Factor, outside: 0 Header Inside Dia. [in] 3/ Stl Colmac Coil Mfg., Inc. PO Box 571 370 N. Lincoln Phone: (509)684 -2595 Fax: (509)684 -8331 Coil is model: BWL- 30x104- 6R- 10E- WR-R /L Job : BOEING 13 -01 S. MEZZ Tag : AHU Fan Capacity [CFM]: 11000 CFM Location : Standard Air Elevation [MSL, ft] : 0 f Connections: <S>ame or <O >pposite: S Ent Air Dry Bulb [degF]: 80 F Ent Air Wet Bulb [degF]: 63 F Solution Face Velocity [FPM] > 508 Number of Rows /F.P.I. > 6/10 Feeds /Passes /Tubes Dropped -> 30/4/0 Calculated Total BTUH > 303150 Calculated Sensible BTUH > 298601 Sensible Heat Ratio > .98 Lv Air Dry /Wet Bulb [ F] > 55.2/53.6 Air Pressure. Drop [iwg] > .773 Leaving Fluid Temp [ F] > 52.4 Fluid Vel[fps] / PD[ft H20] - > 2.9/4.39 Calculations are in accordance with input data and industry practice. See Terms & Conditions of Sale, Warranty, and Limitation of Liability. Date: 11 -03 -1998 RECEIVED CITY OF TUKWILA MAY 1 3 1999 PERMIT CENTER 1. GAYLORD INDUSTRIES AHU SOUND POWER ANALYSIS BOEING 13.03 MEZZ Supply Air: 22,000 CFM (total) Fan Speed: 1,657 RPM 98.5906 Total Static: 5.83 11 w.g. Fan Diameter: 27 inches AHU Supply BHP: 27.00 HP (ea.) Efficiency: 82% Date: 06-Nov-98 Return Air: 0 CFM (total) Fan Speed: 0 RPM Time: 03:57:17 PM Total Static: 0.00 " w.g. Fan Diameter: 0 inches User: JIM H Return BHP: 0.0 HP (ea.) Efficiency: 0% AHU SOUND POWER LEVELS (dB ref. 1 picowatt) Octave Band Center Frequency (Hz) Overall Power Levels 63 125 250 500 1000 2000 4000 8000 LwA Lw (unweighted) Total Inlet Power: 102 95 97 89 86 84 81 74 93 104 Total Discharge Power: 99 92 98 90 87 86 83 76 94 103 Casing Radiated Power: 96 88 80 65 54 44 39 28 76 97 Floor Radiated Power: 91 80 75 61 52 44 35 25 70 92 The sound power levels listed above are octave band values in dB (re. 1 pW). The total discharge and inlet sound power level is the sum of all outlets and inlets, respectively. Sound power levels for individual openings are available upon request. Values are calculated from the computer program FANPWL4 (Version 1.3), Copyright 1996. Casing radiated sound power levels consider only noise radiated from the walls and ceiling of the unit. AIR HANDLING UNIT CONSTRUCTION: (All fans are internally isolated on steel spring vibration isolators) Wall Section Floor Sect. Description Type Length Type AHU Wall Panel Construction 1 FILTER /FAN 5 67 17 2" wall (16 ga.) w /perf. liner 2 COIL 5 46 17 2" wall (16 ga.) w /perf. liner 3 MZ /DISCH 8 33 17 2" wall w/16 ga solid liner FAN ONLY SOUND POWER LEVELS (dB ref. 1 pW) Fan 1 RECEIVED CITY OF TUKWILA MAY . 1 31999 PERMIT CENTER Octave Band Center Frequency (Hz) Overall Power Levels CFM 63 125 250 500 1000 2000 4000 8000 LwA Lw ( unweighted) 22,000 103 95 100 94 91 89 86 79 97 106 Note: Fan only sound power levels represent the inlet or outlet PWL for each fan inside the air handling unit. Fan only sound power levels were obtained from: BARRY ' S • REV, INTL. DATE DESCRIPTION 13 94 Fl G? Ui U U' U )NE DAMPER RD MFG. SHEET NO. WORK ORDER# RECEIVED CITY OF TUKWILA MAY 1 3 1999 PERMIT 4.:ENT ER 559.0601 OF .1ON 113 94 (with view window) / { ^ 21.75" X 5i "(horizonc! mount) 21.75 X 51 ,/,./ I (hinges) ACCESS / / �I1$ / / i FILTER GAUGE 24 66 2 n nn 9 266T ;I I F U 1111, 62 69 L 21.75" X 51 "(hcrizcncl mount) LIFT–OFF ACCESS (no hinge) L BOEING 13 -03 MEZZ. TUKWILLA, WASHINGTON AHU 148 SPLIT 86 21.75 X 51 / �� ACCESS L - - 7 ' 24 18 2 i t i « I 4 7 { 52 / , \ / / 1, \ / // \\ // 1/ \\ // // .0. ... / a: SPLIT 1 i HOT DECK , I t II I I r - - - , •!'......,-- - -��-, I 1 1 I' ' I II / - x % I 1 1 - - _j. ! Itrl 1 1 1 I 1 t 1 1 ,I L A ! e–, 1 , I I 1 !{ / 0 " I L . 1 I 1 i rk - -- y – I II I !I 1 II\ / I III { 't 1 � 1 II •� / ! , I I I II 1 II 1 - -- I. I 1 111286# ._ –� \v I I � H I I ,t 1- 1 J•Y. >�°� 11 I I / 11 1141 t '? IJ H i .1 / 1 I I' 2 `2� s. I {{ 270 I i 1 I / GA 1 / FLOOR BYPASS COLD DECK PERF ,~-- - PRESSURE . c PLATE t v I I 1 00 It 1 x ? I � 0 C '1 { U I 11 I t, i t Ilit ii 11 IItt ;1 L� II � J DRAIN CONN. 79 . l GAYLOP.D , 10900 S.W. AVERY ST. TUALA111N. OR. 97062-1149 (503) 691 -2010 r 2.75 115.5 121 8.34 30 34 22 SPUT — 66 100.34 r 1.38 1 7 t I 3.5 DRAWN BY <ES �) Auto SNoT OFF 'REQuIRlD u.M.c • seuzroN (bob, z) s«►oucl nat I IMMps1t s DATE i /2/98 TRIPLE DECK MULT1ZONE DAMPER PROVIDED BY OTHERS. INSTALLED BY GAYLORD MFG. FOLE COPY 0: 11zi s Q ,.pM6 REVISION IL I WORK ORDER# SHEET NO. 8590601 4 OF 4 •L :zz: _ =ter -� - :_ -t ._ - i I I 1 I I _ _ -i '-t J L • • •,./ 1 , � I I ■ 1 ! 1 7 1 I i I I I I 1 1 1 I I I I I 1 1 I y S i' f � I II I '11 V1 fill � -__ I N G 3,1.1. .� ; .• l ). ' fi r ', N �� •' _• __ I I I 1. 11 ut U rcnt 11 JJ�W1 1 L___.�I (with view window) /\ 21.75 X 5i / /� // \\ 1 ACCESS / / 1 6 113 FILTER GAUGE 2 :REV. INTL. DATE DESCRIPTION . 75 X 51 "(hcrizonci mount LIFT —OFF ACCESS (no hinge) Y 62 r 21.75" X 51 "(horizonct mount) (h inges) � o 69 BOEING 13 -03 MEZZ. TUKWILLA, WASHINGTON AHU 52 /X■ M / \\ // \\ I I/ \ \ // \\ 1 Ii L II 270 270 I i 1 HOT DECK rr /6} L� . BYPASS COLD DECK J i PERF J _i PRESSURE PLATE o 0 ? 1 0 \\ I 14 GA. FLOOR Ir ,z i1 .I 148 SPLIT 86 � GAYLOP.D DRAIN CONN. 79 . 10900 S.W. AVERY ST. TUALATIN, OR. 97062-1149 (503) 691-2C10 � /le. `� ACCESS 51 24 9 r 1.38 2.75 115.5 121 8.34 30 34 22 SPUT — 66 DRAWN BY KES L v 100.34 Mow: AuTO 51ho'r or 'R V.M G • SacTroN 60$, z) srwora/ flRt 1 1:•AA 5 lb Swts?be+t TRIPLE DECK MULTIZONE DAMPER PROVIDED BY OTHERS, INSTALLED BY GAYLORD MFG. DATE 11/2/98 Nit REVISION WORK ORD_RRF: SHEET NO. RETURN FAN QTY: 1 CFM: 18,000 ARRG: 3 SHAFT: SOLID ALT: 0 FT SIZE: 27" ESP: 1.34" W.G. DISCHARGE: THD SFT. O.D.: 2.1875" OPER TEMP: 70 ° F WD: DWDI TSP: 1.5" W.G. ROTATION: CW BRG TYPE: PILLOW BLOCK CLASS: I RPM: 485 O.V. (FPM): 2386 BRG O.D.: 2.1875" BLADES: FC BHP: 8.05 DEFLECTION: 1.0" MFR: 190100 MODEL: 270 VERSACON FC DWDI NOTES: RETURN FAN MOTOR HP: 10 MOTOR VOLT: 230V/460V FRAME: 215T EFFICIENCY: 91.7% RPM: 1760 OPER VOLT: 460V CONST: ODP (Premium Eff.) SHAFT DIA. 1.375" PHASE: 3 FREQ: 60Hz FLA: 12.9 MFR: 020018 MODEL: EM3313T RETURN FAN MOTOR BASE QTY: 1 MFR: 070070 MODEL: 215T Frame - Model# 3M282 - Gaylord Stock# 14423 RETURN FAN DRIVES DRIVER: 2TB56 X 1.375 (5.6) L. FIXED • ADJ. DRIVER BUSHING: P1 X 1.375 DRIVEN: 2TB200 X 2.1875 (20.0) DRIVEN BUSHING: 01 X 2.1875 MFR: 130015 RATE BHP: 15 HP NO. OF BELTS: 2 BELT TYPE: B ELECTRICAL SERVICE FOR MOTOR MAIN VOLTAGE: 460V /3Ph /60Hz FULL LOAD AMPERAGE: 12.9 0 ALL WIRING BY OTHERS MIN CIRCUIT AMP.: 17.5 MAX FUSE SIZE: 25 MAX. BREAKER SIZE: 40 NOTES: UNIT WT: 3157 LBS. L v , IODEL NO: CSU- 12K -H -15 QTY: 1 REVISION N0. � BOEING 13 -01 MEZZ. TUKWILLA, WASHINGTON SUBt 'J� u SALE ENG: TE: : 8 =89061 "" 3 1999 1 PERMIT CENTER CSU ENGINEERING DATA 2 g 1999 1090C1`1�V�VW159'1 TUALATIN, OR 97062-1149 (503) 691-2010 C hec tc �c�s� �• 11 1211 1t,e ('k`'n . _ . tt1 t�r�r' III REV /DATE/INIT : .,1 ' TAG NO RAF WORK ORDER - '8590602 SHEET NO: 1 OF 3 vqq cx;xJLI ELECTRICAL SERVICE FOR LIGHTS MAIN VOLTAGE: 120V/1 Ph /60Hz CI WIRE LIGHTS TO SWITCH & J -BOX FULL LOAD AMPERAGE: .83 MAX FUSE SIZE:15 (1) 100W MARINE VAPORPROOF LIGHT NOTES: CASING CI STANDARD - INDOOR GAUGE: 16 GA CASING / 14 GA FLOOR MAT: GALV. A -60 • WP1 - OUTDOOR FINISH: GRAY ENAMEL ROOF CURB: NONE • WP2 - OUTDOOR w /Curb Angle INSUL: 2" 3# DENSITY GALVPERF LINER NOTES: 1. Fan access door requires Mechanical Latch (tool required for opening door). ACCESS DOORS QTY: 1 OPTIONS: ® 12 X 12 DOUBLE PANE WIREGLASS VIEW WINDOW MFR: 030020 MODEL: HF20- 21.75 "W X 51 "H -EGO ACCESS DOORS QTY: 1 MFR: 030020 MODEL: HF20- 21.75 "W X 51 "H -EGO BOEING 13 -01 MEZZ. TUKWILLA. WASHINGTON SUBMITTED BY: KES FILE NO. 98-5906 SALES ENG: JH DATE: 11/6/98 CSU ENGINEERING DATA 10900 SW AVERY ST. TUALATIN, OR 97062-1149 (503) 691.2010 REV /DATE/INIT TAG NO. RAF CiTI OF ?uKWIIA vim 1 31999 pow CENTER WORK ORDER 8590602 SHEET NO: 2 OF 3 REV. /DATE DRAWN BY KES TAG NO. 23" X 60" OPEN AREA WITH NO SUPPORTS TO ALLOW FOR FIELD PENETRATION. (trim spring pads as req'd.) DESCRIPTION RAF DATE 11/5/98 ,/;\ ACCESS / \ 21.75 X 51 i i \ � I Lc — —1 r �Tr rr '�rit`'1m IL` LJ, .1] I LAJUSA I 1 — —1 1 I I I II I I II i i -- - --1 - -- - - - - I r r I I I I �I I J Z I nnn I c.C� r uuw _ Tr- I r -- .1. 11 � I I I =c2 7 � II t- ----, r -" - - -I I I Irr1P,S1I I r'nj 1 I • I ACCESS \\ \\ / 21.75 X 51 \ \. / PLAN VIEW (with view window) y 81 77 RETURN FAN J - 1' 1 2 -.-I h'— 23 X60 "W OPEN AREA WITH NO SUPPORTS TO ALLOW FOR FIELD PENETRATION. ELEVATION VIEW GAYLORD 10900 S.W. AVERY ST. TUALATIN, OR. 97062 -1149 (503) 691 -2010 2 23 25 38,5 85 23 25 1 28 75 28 4 BOEING 13-01 MEZZ. TUKWILLA, WASHINGTON WORK ORDER# SHEET NO. 35 66 73,5 ary or MAY 1 3 1999 PERMIT CENTER 8590602 3 OF 3 • BarryBlower 10/23/1998 Project: Arch /Engr: Purchaser: Conditions: Standard Volume: 18,000 Static Pressure: 1.500 Alt. Above Sea Level: 0 Temperature: 70 Size 270 VersaCon FC DWDI Fan Construction Class I Inlet Vanes None Fan RPM 485 Brake HP @ Oper. Cond 8 05 HP including drive losses 8 49 Tip Speed 3,427 SOUND DATA: Octave Band: Sound Power: LwA: 96 db BOEING., 13 j FAN SELECTOR GUIDE Copyright 1984, 1992, 1994 FOR EXCLUSIVE USE OF GAYLORD INDUSTRIES .075 lb/ftA3) CFM in.SP Ft. Deg. F. Version 4.5 Units English Wheel Width 100% Standard Selection Criteria Specified Fan Size RETURN FAN Operating (.075 lb /ft ^3) 18,000 CFM 1.500 in.SP 0 Ft. 70 Deg. F. Mechanical Efficiency 65% Static Efficiency 53% Outlet Velocity 2,386 WRA2 If 1150 RPM Motor NOT AVAIL. WRA2 If 1750 RPM Motor NOT AVAIL. Wheel Mtl/Derate Std Steel /1.00 Point of Operation 56% WOV Wheel Diameter 27.000 IN Maximum RPM Class I 673 Maximum RPM Class II 795 -1- -2- -3- -4- -5- -6- -7- -8- VALUES INTERNAL TO INLET OR 103 97 101 90 85 88 80 70 OUTLET (REFER. TO 10A -12 WATTS) dbA: 88 db ® 3 feet (REFERENCED TO 10 ^.-12 PASCALS) CITY OF T MAC 1 3199 PERMIT CENTER ........................................................................... ......................... -PROJECT : BOEING 13 DATE: TAG: RETURN FAN MODEL: 270 FC Di4DI OPER. CONDITIONS . . . . . . . . . . . . . . ..--.- 2. . . . . . . . . . '. • . . - . . . . . 1.5- 1.0- 0.5' . . - • - • RPM 405 BHP 8.05 CFM 18000 SP -' 1.50 .......... RPM 485 BHP 8.05 CFM 18000 SP 1.50 ALT 0 TEMP 70 STD. CONDITIONS - • - • - • • • • • • • • • - • % - • . • • • . • • • • - • • • • • • - • - • • - - • . • • • • • . • • • % • • % • • . • • • • .. • . - - • 5 et >, .0 BOEING 13.03 MEZZ 98.5906 RAF Date: 06- Nov -98 Time: 04:16:58 PM User: JIM H AHU SOUND POWER LEVELS (dB ref. 1 picowatt) Total Inlet Power: Total Discharge Power: Casing Radiated Power: Floor Radiated Power: The sound power levels power level is the sum available upon request Casing radiated sound Sect. Description 1 INLET 1 INLET 2 FAN FAN ONLY SOUND POWER LEVELS (dB ref. 1 pW) Fan CFM 1 GAYLORD INDUSTRIES AHU SOUND POWER ANALYSIS Supply Air: 18,000 CFM (total) Total Static: 1.50 " w.g. Supply BHP: 27.00 HP (ea.) Return Air: Total Static: Return BHP: 103 98 96 103 97 101 95 89 79 88 78 70 0 CFM (total) 0.00 " w.g. 0.0 HP (ea.) Wall Section Floor Type Length Type AHU Wall Panel Construction 5 24 17 2" wall (16 ga.) w /perf. liner 5 24 17 2" wall (16 ga.) w /perf. liner 5 54 17 2" wall (16 ga.) w /perf. liner Octave Band Center Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 18,000 103 97 101 90 85 88 80 70 Fan Speed: 485 RPM Fan Diameter: 27 inches Efficiency: rSSge Fan Speed: 0 RPM Fan Diameter: 0 inches Efficiency: 0% Octave Band Center Frequency (Hz) Overall Power Levels 63 125 250 500 1000 2000 4000 8000 LwA Lw (unweighted) 82 77 80 73 63 90 105 90 85 88 80 70 96 106 58 44 40 28 23 76 96 50 38 36 23 21 67 88 listed above are octave band values in dB (re. 1 pW). The total discharge and inlet sound of all outlets and inlets, respectively. Sound power levels for individual openings are . Values are calculated from the computer program FANPWL4 (Version 1.3), Copyright 1996. power levels consider only noise radiated from the walls and ceiling of the unit. AIR HANDLING UNIT CONSTRUCTION: (All fans are internally isolated on steel spring vibration isolators) RECEIVE=D CITY OF TUKWILA MAY 1 3 1999 PERMIT CENTER ,., s ............ . . :=.4»:....44144..... r +._.»•••..r». 1 ..::............ �..«'.:....: �...+.. •' K" 1 ti::.' J:;':::::. 1: �« Ul..... .L'};1 i4iiL:�.. ....: '.1MS..r. _ .._. !. n�. • oe.��; ^. gtlr l.+.w..r. -..... .. ... Overall Power Levels LwA. Lw (unweighted) 96 106 Note: Fan only sound power levels represent the inlet or outlet PWL for each fan inside the air handling unit. .. Fan only sound power levels were obtained from: BARRY June 13, 2000 City of Tukwila Department of Community Development 6300 Southcenter Blvd., Suite #100 Tukwila, WA 98188 ATTENTION: Bill Rambo PROJECT: Boeing 13 -01 and 9 -96.2 SUBJECT: Request for Extension for Permits M99.0004 and M99 -0187 Gentlemen: HERMANSON COMPANY ALP • Mechanical Contractor 1221 2nd Avenue North, Kent, WA 98032 • Phone: (206) 575 -9700 • Fax: (206) 575 -9800 http: / /www.hermanson.com We request an extension to permits M99 -0004 and M99 -0187 do to extenuating circumstances beyond our control. The Boeing Company is not due to have the corrections completed on permit M99 -0004 until the end of June or the first of July. They are also working on the corrections on permit M99 -0187 with their engineers. Please call if you have any questions or comments. CONSTRUCTION Sincerely, HERMANSON COMPANY, LIP Dennis McCarter Foreman for Special Projects Division DM /dwg MANAGEMENT RECEIVED JUN142000 COMMUNITY D EVELOPMENT v. ,,,t'n i'.'L'T,'!` - Ro.AimjnVpt June 6, 2000 Randy Mead 1221 2 " Ave N Kent Wa 98032 �r City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Status. M99 -0004 10000 East Marginal Way S Dear Mr. Mead: In reviewing our current permit files, it appears that your permit to install new supply and return air grilles and duct work, issued on January 28, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206) 433 -7165 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician Xc: Permit File No. M99 -0004 Duane Griffin, Building Official . ww4+. wri. vw. r. r rwvrvs+». wNra.a.•n�w.e..w.saNr✓i[wTtF�i Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206.431.3665 January 11, 2001 Randy Mead 1221 2 AV N Kent, WA 98032 SUBIECT: Dear Mr. Mead: City of Tukwila Department of Community Development Steve Lancaster, Director Permit Status #M99 -0004 Boeing #13 -01 Bldg. 10000 E Marginal WY S In reviewing our current permit files, it appears that your permit for the installation of Supply diffusers /Return Air Grilles /Duct work that was issued, on January 28, 1998 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non- complying and not in conformance with the Uniform Building Code and /or Uniform Mechanical Code. Please contact the Permit Center at (206) 431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, C i i rnirr t Tammy Beck Permit Technician File: M99.0004 latfic4 Phone: Fax:, 206) 575 -9700 206) 575-9800 743 - 31 Steven M. Mullet, Mayor Hermanson Company MECHANICAL CONTRACTOR MANAGEMENT • . CONSTRUCTION • ENGINEERING 1221 2nd Avenue North, Kent, Washington 98032 http: / /www.hermanson.com Dennis McCarter Foreman 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206.431.3665 PROJECT NAME: BOEING 13 -01. BLDG. Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Val Building Division Public Works Complete n Incomplete ri TUES /THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: Approved ri Approved with Conditions \PR•ROUTE.DOC 6/98 C PLAN REVIEW /ROUTINia SLIP ACTIVITY NUMBER: M99 =0004 DATE:. 5 - -99 Response to Incomplete Letter XX Revision # 1. After Permit Is Issued O Fire Prevention Planning Division 5 -2017 Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 5 -18 -99 Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) Not Applicable [l Comments: No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE: 6 -15 -99 Not Approved (attach comments) r-=1 Approved n Approved with Conditions Not Approved (attach comments) E REVIEWER'S INITIALS: DATE: DUE DATE: REVIEWER'S INITIALS: DATE: Perini f C Copq PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M99 -0004 DATE: 1-8 -99 PROJECT NAME: BOEING 13 -01 Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Bng Division Public Works �� El DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ❑ Incomplete TUES /THURS ROUTING: Routed by Staff REVIEWERS INITIALS: Jo Fire Prevention MGM- 1 =1L Structural APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions Approved \PR•ROUTE.DOC 6/98 (if routed by staff, make copy to master file and enter into Sierra) Planning Division Permit Coordinator DUE DATE: 1 - 12 - 99 Not Applicable ❑ Comments: Please Route ❑ No further Review Required C DATE: 2 - - 99 DUE DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: Revision No. Date Received Staff Initials Date Issued Staff Initials ° L , Summary of Revision: Summary of Revision: Add �' �laslrl 1 e19 Received By: Revision No. Date Received Staff Initials Date Issued Staff Initials ° L , Staff Initials Summary of Revision: Add �' �laslrl 1 e19 I ) n t Specs Received By: (DAM j7 Coo _s f Revision No. Date Received Staff Initials Date Issued Staff Initials Summary of Revision: Received Byi` AVi (by t., '( i PROJECT NAME: &C 3-01 Site Address: 10000 Cl i naI i 3j Original Issue Date: 1 - 2e - 19 J REVISION LOG Revision No. Summary of Revision: WC1 ri Revision No. Summary of Revision: Date Received Staff Initials Mate itaff Received Initials Received By: Received By: } _� 1c R Q000L1 PERMf�,NO:. , Date Issued Date Issued (please print) (please print) (please print) (please print) (please print) Staff Initials Staff Initials CITY OF TUKWILA Department of Community Development Permit Center 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Date: 5/3/TT ❑ Response to Incomplete Letter ❑ Response to Correction Letter Revision after Permit Issued CRY OF TUIIWILA gpprtuV RE VIS 10 MAY 2 8 1999 r∎J viu IL. 0 "Cloud" or highlight all areas of revisions and date revisions. Submitted to City of Tukwila Permit Center fir in Sierra on Plan Check/Permit Number: NA `l°I - 000 Project Name: 'oe (-I C% 13 'O 1 ee7 Project Address: l 000 d EA M A raco kiAL WA '( Contact Person: - PA-VI a ut-s ti' Phone Number: 2 s'S - SLI 33 Summary of Revision: 41) D 77 ° " " or /1 /2 I4 u,Jlir _ SP(U ( I c 77oAJS 7141 S vIervtt tr VIA-S CAi Le'O ex) T o Ti S Qe, l -i trre tDeAv.' . 6 UT Si -I F t G A 'n o /NIS $645 t•-1 //JCL U l7 67) 'Roes J c Fug 4is14 0 /J1 i AS 1 LA'S A� 13.111_f�l� N DtVt9tON Sheet Number(s) C Pt4L-a ,niDU Sled ES CQ U I PMT 0/4 6_ B M (Tr ,� t_ RECEIVED CITY OF TUKWILA MAY ! 3 1999 PERMIT CENTER 3/4199 Dear Sir: City of Tukwila Fire Department Fire Department Review Control #M99 -0004 (510) May 21, 1999 Re: Boeing Company Building #13 -01 - 10002 East Marginal Way South The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575 4404 • Fax 1206) 57544139 Page number 2 commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2. A permit is required to install or operate a mechanical refrigeration unit or system. (UFC 105.8 -r.2 article 63) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, City of Tukwila Fire Department • The Tukwila Fire Prevention Bureau cc: TFD file ncd 5( O Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 Phone: (206) 5754404 John W Rants, Mayor Thomas P. Keefe, Fire Chief Fix (206) 57554439 9 REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY REGIST. # EXP. DATE CCAFCG HERMAC*217NT 07/27/1999 . EFFECTIVE DATE , 08/30/1979' HERMANSON CORPORATION 1221. 2ND AVE N. KENT WA 98032 Signature - --e- 1< Issued by DEPARTMENT OF I43OR AND INDUSTRIES v oVi 360 CFM 12'INECK 490 CFM 12" }NECK 490 CFM 12" }NECK 450 CFM 12 "6 (TYP.) 6 28/10 18/10 s A 100 CFM 6" }NECK . i 1 0X14 EX. 290 CFM RILL 44 t RILLE nO I r35 CFM 1[8/6 Alam 10X14 E GRILLE 235 CFM VAL W.11 , 7i Ii i1i7 r• 12 8 Ilk) 420 FM ♦>_.. 8 12/ EXH. 100 CFM 1M 14b .e rEki' 35/12 280 CFM 35X12 UP ZONE 1.4 ZONE 1.3 ZONE 1.2 ZONE 1.1 l . 'GRADE 13 -01 GRADE 13 -01 REVISION 782758 -05 782758 -06 BY HARRAH HARRAH APPROVED OS DATE REVISION BY APPROVED P LAN SCALE: 1 /8' =1 DATE �BOEBiVG� r7 MOM II RINIMMT • SHOEMAKER SERIES 90 10 " GRILLE W /OPTIONAL SERIES 91 DAMPER, WHITE. 200 CFM EACH (TYP. 14 PLACES) INSTALL HVAC SYSTEM UNDER MEZZ. AS SHOWN, M99 -0004 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. SUBTITLE HVAC DUCTWORK - PLAN VIEW REMOVAL i understand that the Plan Check approvals are sowed to errors and omissionsand approval of plans does not authorize the violation of any adopted node or ordinance. Receipt of con tractor's 86 ty of approved .fans acknowledged.. I By 4 ►� 1l.�.�- , Dato • - - • BUILDING 13 -01 COL. 1 -8 /A -E LEGEND: 1. RETURN GRILL P.O.C. • POINT OF CONNECTION FLEXIBLE DUCT WITH VOLUME DAMPER MTADIM Fitz 24'0 SUPPLY OUTLET CONSTRUCTION NOTES RETURN REDLINED DRAWINGS SHOWING AN -' DEV I =.T I ONE FROM OR I GNAL DESIGN TO ENGINEER ; C' =,UCF: HARRAH , M/S 46 -87, PH: 655 -3003. 1� REMOVE PRESSURE DAMPERS & SENSORS FROM DLOT (5 .LACES • REMOVE ALL DIFFUSERS IN SUSPENDED CEILING AND CAP DUCTS (29 PLACES) • REMOVE SHEET METAL DUCTING INDICATED BY " . ® CAP DUCT (1 PLACE) 340 CFM 17 GENERAL NOTES: MFC JOB DIFFUSER RECTANGULAR DUCT, FIRST NIL MBE?. INDICATES SIZE FOR SIDE SHOWN. ROUND DUCT, NUMBER INDICATES DIAMETER AIR DIFFUSER /REG I STAR /GR I _L . REFER TO SHEET MIA. 2 -WAY EARTHQUAKE BRACING, SEE 4 -WAY EARTHQUAKE BRACING, SEE ALL DUCT DIMENSIONS SHOWN ARE I ! DE CLEAR. ALL DUCTS WHOSE GREATEST DIMENSI ON IS 30" OF LESS SHALL BE 24 GAUGE GALVENIZED SHEET META_ 3. ALL DUCTS WHOSE LARGEST D I MENS I ON I S B ETWEEP. 31 " AND 54" SHALL BE 22 GAUGE GA.! VAIN I ZED SHEET METAL. 4. ALL DUCTS WHOSE LARGEST D I MENS I C'J I S E ETWE EN. 55" AND 84" SHALL BE 20 GAUGE GA_VAN I LED SHEET METAL. 5. ALL DUCTS WHOSE LARGEST DIMENSION IS GREATER THAN 85" SHALL BE 18 GAUGE GALVAN I ZED SHEET METAL. 6. REINFORCE DUCTWORK EVERY 4FT. MAC :. AND SUPPORT EVERY 8FT, MAX. 7. USE NEXUS JUNIOR TYPE JOINTS WITH GASKET, OF EQUAL, WHERE EVER POSSIBLE. 8. Al L SUPPLY DUCTS WITHIN THE BU II_ DING SEAL'_ BE WRAPPED WITH 2 "THICK, 1.5 POL':D DENSITY FIBER GLASS INSULATION WITH AN A_UM I NUM. FOIL FACE, REINFORCED WITH FIBEF GLASS YARN MESH AND LAMINATED TO•FIRE RESISTANT KRAFT MANVILLE 800 SERIES SPIN GLAS W i -H = SK FACE OR APPROVED EQUAL. 9 . DIFFUSER SIZES INDICATED ARE NEC : SIZE S DIFFUSERS ARE 24 "X 24" -BAP LA` - N. l',ii: Cif - 'ILL:• i'Ll'. r,1 > FRUTNO 2 7 19I-i9 \J A FILE COPY 2 0 `" /C n"J" 11'1 kif %%% "i; CURRENT REVISION KEY VIEW SCALE: NONE SYMBOL 1M1OR - 98 -06 13- 01 -1M1OR a. R1N' - DATE COMP NO M504 X504 sewage. FOR. ED a MECHANICPI 0 ELECTRICAL i 0 PLUMBING 0 GAS PIPING gJry 00 1I30 ECUOILDIP DIVISION RECEIVED cav OF TUKWILA JAN 0 8 1999 PERMIT CENTER Mcri-o0o4 SYM A 35/12 24/12 22/10 14/10 EX 230 CFM 2 12//8 EX f14D CFM ZONE 3 DIFFUSER DETAIL (TYP.) 2M10 1M507 SHOEMAKER SERIES 700MA -0 14x14 DIFFUSER W\ 8' NECK 200 CFM PER DIFFUSER UNLESS OTHERWISE NOTED 54PLACES) SHOEMAKER SERIES 600PTFG 2'x4!' RETURN AIR GRILLE DUCT HANGER TYP 2M10 1M507 600 EX. GRILLE 100 CFM ZONE 1 ZONE 2 ZONE 3 ZONE 4 35X12 UP SHOEMAKER SERIES 600PTFG 2'x2' RETURN AIR GRILLE (TYP. 5 PLACES) FOR DUCT CONTINUATION SEE DWG 2M10 20/28 UPGRADE 13 -01 UPGRADE 13 -01 1ST FLR REVISION 782758 -05 782758 -21 BY HARRAH HARRAH APPROVED DATE SYM REASON BY APPROVED PLAN SCALE: 1/8' =1' -0" DATE �BOE /ArG ' 20-- • 1 I21 1 M99 -0004 0 0 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE SHOEMAKER SERIES 90 10'0 GRILLE W /OPTIONAL SERIES 91 DAMPER, WHITE. 200 CFM EACH (TYP. 14 PLACES) DRAWN C. HARRAH Z ECKED HECKED PPROVED PPROVED - DATE 10.9.98 nTLE MECHANICAL MASTER SUBTITLE HVAC DUCTWORK - PLAN VIEW BUILDING 13 -01 COL. 1 -8 /A -E LEGEND: 0 DIFFUSER rg P.O.C. mu t 340 CFM EL 1. 2. RETURN GRILL POINT OF CONNECTION FLEXIBLE DUCT WITH VOLUME DAMPER RECTANGULAR DUCT, FIRST NL ME-F INDICATES SIZE FOR SIDE SHOWN. ROUND DUCT, NUMBER INDICATES DIAMETER SUPPLY OUTLET.. AIR DIFFUSER /REGISTAR /GRILL SHEET M1A. 2 -WAY EARTHQUAKE BRACING, SEE EARTHQUAKE BRACING, SEE ?.EFEF TO -' Th:14 GENERAL NOTES: ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. ALL DUCTS WHOSE GREATEST DIMENSION 15 30" OR LESS SHALL BE 24 GAUGE GALVEN I ZED SHEET METAL 3. ALL DUCTS WHOSE LARGEST D IS BETWEEN 31 AND 54" SHALL BE 22 GAUGE GALVANIZED SHEET METAL. 4. ALL DUCTS WHOSE LARGEST DIMENSION IS BETWEEN 55" AND 84" SHALL BE 20 GAUGE GALVANIZED SHEET METAL. 5. ALL DUCTS WHOSE LARGEST DIMENSION IS GREATER THAN 85" SHALL BE 18 GAUGE GALVANIZED SHEET METAL. 6. REINFORCE DUCTWORK EVERY 4FT. MAX. AND SUPPORT EVERY 8FT. MAX. 7. USE NEXUS JUNIOR TYPE JOINTS WITH GASKET, OR EQUAL, WHERE EVER POSSIBLE. 8. ALL SUPPLY DUCTS WITHIN THE BUILDING SHALL BE WRAPPED WITH 2 "THICK, 1.5 POUND DENSITY FIBER GLASS INSULATION WITH AN ALUMINUM FOIL FACE, REINFORCED WITH FIBER GLASS YARN MESH AND LAMINATED TO FIRE RESISTANT KRAFT. MANVILLE 800 SERIES SPIN GLAS WITH FSK FACE, OR APPROVED EQUAL. 9. DIFFUSER SIZES INDICATED ARE NECK SIZES DIFFUSERS ARE 24 "X 24" T -BAR LAY -IN:. CONSTRUCTION NOTES RETURN REDLINED DRAWING SHOWING ANY DEVIATIONS FROM ORIGINAL DESIGN TO ENGINEER: CHUCK H/.RTA- M/S 46 -87, PHONE 655 -3003. INSTALL HVAC DUCTING SHOWN IN BOLD LINES. ATTACH TO EXISTING DUCTING 6 P.O.C.. (5 PLACES) INSTALL DIFFUSERS AND FLEX DUCT IN EXISTING SHEETMETAL DUCTWORK AS SHOWN. USE 8 "0 SPIN IN COLLARS `. /DAK:PERS, INSULATED FLEX DUCT, AND 2'x2• 4 -WAY DIFFUSEFS. (54 DIFFUSERS) INSTALL RETURN AIR REGISTERS WHERE SHOWN (6 FLACES) BALANCE AIR FLOWS PER CALLOUTS, MFC SHEET R1M1Q CURRENT REVISION KEY VIEW SCALE: NONE SYMBOL 1M10 JAN 27 JOB NO. 782758 -05 DWG N0. 13- 01 -1M10 R1M'.. CITY DEFINED TUKWILA JAN 0 8 1995 PERMIT CENTER COMP NC. DATE 10.26.9 SYM REVISION BY APPROVED DATE SY REVISION BY APPROVED DATE II 16 DN OM ROO ACCEPTABILITY SPECIFICATION ID APPROVED 16/1 � 1l.[R FROM O:c E liiiiiif iii- DN ROOF iT!; �1:� N4i 6 DN ROOF • SUBTITLE DUCTWORK - CURRENT REVISION SYMBOL X 1 25 3 % ® — ��. Qp1 ( I - y -q Pii {, I A 1 4 B • - � z U---- � � II � o CHECKED SHEET 2 M 10 R � �_- I : y _' �/s U� woz II 16QI� ZAPPED E05; 24/26 RFT. L ► � - UP TO ROOF s�.�� /48 EXH) DEPT. DATE ENGINEER It lOr • 2 M.F.C. - 00 CFM . -, • l 1, 24/12 EXH. L — - • • • e 0. 8 CHECKED j 12/12 FROM ON ROOF ,, 5 2 3 a /7 ■ 300 CFM L II �iy ` m IN APPROVED JOB NO. 782758 -05 •._ I r , 3 2 EX 331 CFM � ,'. 1• ' I to °. • h � ma1� 5 • r .. r. ghz i = - - - owo No. 13- 01 -2M1OR 11111 ®Q I ' 11212:1E4 8 - �! mo 12/8 DN FROM R►Y= • � ' g:� l e Q ♦a 8161) _ 7 w F si cc: i N. 600 C 22 24 ' r ' . 4 - ► 14/14 DN 4 ��� 11/8 ►� �� • • / • 111=1111 ►\ FROM ROOF .4 �. - - ��\ 'G _ ��..� —6 � � • - a. moo.. .. ►v 200 CFM CFM • • 175 CF j • EG 1 FM V _ � yy `- ._2 \ � .:i �. a� � "I Q� . a - - -. 200 CFM CI I'. - R 2640 (��.y �p I CFEX /` ►_ 24/48 EXH. •• CFM 1 / ►. . �. ZONE 1.4 ZONE 1.3 � - 17 _ l • 1 o • 00 �•'l!a� ,,,,w ?�tEENE; fi•��i R � 'e' E.:.� ONE 1.2 0 ....,-„••• ONE 1.1 i ` ONE 2.1 ABANDOND NE 2.2 ABANDON D 4 20 CFM a I� • • 200 .FM a • Mi a • I a ' 200 M � 12/24 EX .�j „ � •,� 630 CF ' ACV., - 18 4 >',.. 0� ,.� . — % ���4�] = - 135 . • 80D M � .I --"' 6” _ ZO 2.4 O ' ' g �? I<��!` : � C��i• •� 1i I 4 zoo FOR DUCTWORK THIS AREA • i 16 o � 0 - .. 175 CFM 13 . ∎'�alr•MrQI 1t � 12 S 13.01- 2M5i6R °; -- a 41Rii l i • u s CFM CFM 2-- 175•CFM • 2 A • • , - , 36/20 o -� .•ter 2 2 , - n © • : �r ©I ' - 200 CF M 200 "�` 12/24 EXH 450 CFM �s _ SHOEMAKER SERIES 700MA -0 IF s�._,. ._, r.... v IFFUSER DETAIL TYP. ( ) 1 4x1 4 DIFFUSER W\ 10" NECK CFM AS NOTED (TYP 16 PLACES) DIFFUSER DETAIL ( 2M10 1M507 YP,) (1\ SYM REVISION BY APPROVED DATE SY REVISION BY APPROVED DATE ® ' i,,,..._ ACCEPTABILITY SPECIFICATION ID APPROVED DRAWN C. CKERAH DATE 8.1.98 SUBTITLE DUCTWORK CURRENT REVISION SYMBOL X DATE 25 3 X 13 - 01 BLDG. UPGRADE 782758 - 20 C HANNAH ��. Qp1 ( I - y -q CHECKED SHEET 2 M 10 R APPROVED BY DEPT. DATE ENGINEER TITLE MECHANICAL MASTER BUILDING 13 -01 COL 1 -8 /A -E M.F.C. CHECKED APPROVED JOB NO. 782758 -05 COMF •._ APPROVED owo No. 13- 01 -2M1OR PLAN SCALE: 1 /8" =1'- M99 -0004 2M10 1M507 REMOVAL LEGEND: 1. 111 ® RETURN GRILL P.O.C. POINT OF CONNECTION 340 CFM a DIFFUSER - FLEXIBLE DUCT WITH VOLUI/E DAMP-- za Iz Y 24'0 3 r 2a'm SUPPLY OUTLET GENERAL NOTES: RECTANGULAR DUCT, FIRS JE'BEF INDICATES SIZE FOR SIDE E - - ' ROUND DUCT, NUMBER IND' 11ATES C - ME AIR DI FFUSER/REG I STAR, F I - SHEET M1A, 2 -WAY EARTHQUAKE BRACE:'_, S 50,4 4 -WAY EARTHQUAKE BRAG•.:. SEE - 2 ALL DUCT DIMENSIONS SHOWN ARE I f " OE ALL DUCTS WHOSE GREATEST DIMENS IS = LESS SHALL BE 24 GAUGE GALVENI2EC S-IEE vC AL 3. ALL DUCTS WHOSE LARGEST DIMENSI C '. I S BETW `= N 31 " AND 54" SHALL BE 22 GAUGE GA._ VAN I T=D SHEET METAL. 4. ALL DUCTS WHOSE LARGEST D I MENS I C C. I S 55" AND 84" SHALL BE 20 GAUGE G , I Z SHEET METAL. 5. ALL DUCTS WHOSE LARGEST DIMENSI Cr I S GE.E. =TER THAN 85" SHALL BE 18 GAUGE GALA A.': ZED c H_ El METAL. 6. RE DUCTWORK EVERY 4FT. N! =. AND SUPPORT EVERY 8FT. MAX. 8. ALL SUPPLY DUCTS WITHIN THE BUI ND SHALL BE WRAPPED WITH 2 "THICK, " 'DUI' DENSITY FIBER GLASS INSULATION o. - F AN ALUMINUM FOIL FACE, REINFORCED r. F El.'. FIBER GLASS YARN MESH AND LAM I N- - E D TO = RESISTANT KRAFT MANVILLE 800 SE= ES SP ;_ qc WITH FSK FACE, OR APPROVED [QUA _ 9. DIFFUSER SIZES INDICATED ARE NE SIZES DIFFUSERS ARE 24 ° X 24" T -BAR LA - - N NOTE: CFM "S SHOWN ARE MAXIMUMS FOR SETT UP SELF ADJUSTING DIFFUSERS WHICH ARE ACCUTHERM MOD, TF -HC, MINIMUM FLOW SHAL CONSTRUCTION NOTES RETURN REDLINED DRAWING SHOWING ANY DE • DNS FROM ORIGINAL DESIGN TO ENGINEER: CHL1 =.RF - M/S 46 -87, PHONE 655 -3003, REMOVE PRESSURE DAMPERS & SENSORS FROM DUC =LA.- E_ REMOVE ALL DIFFUSERS & FLEX DUCT I N SUSPENC = C E I L ^. AND CAP DUCTS (29 PLACES) REMOVE SHEET METAL DUCTING INDICATED BY "X' oc )'31 � Z)glniD!OZxO)(__ L2M10 KEY VIEW SCALE: NONE 2M1 p,4', 2.1 "T3MIT CENTER RECE CITV OF T JAN 0 8 1999 CAPPED P.O.0 2 EX CFM Ai ZONE 8 &9 •� P.O.C. 36/20 mmmmmm°wr -- 0-.-ZONE P.O.C. DUCT HANGER TYP 2M10 1M507 12/24 ONE 10 SHOEMAKER SERIES 700MA -0 18/10 14x14 DIFFUSER W\ 8' NECK 200 CFM PER DIFFUSER UNLESS OTHERWISE NOTED (61 PLACES) DIFFUSER DETAIL (TYP,) 2M10 1M507 ZONE ZONE 2 2 ZONE 4 3 ZONE 5 0 ONE 6 aE7 ZO . 8 0 ZONE 9 F OR DUCTWORK ZONE 10 TH I S AREA SEE 13,01 -M516 200 CFM 200 CFM 200 CFM 200 CFM 175 CFM D UCT HANGER DETAIL DIFFUSER DETAIL (IYP.) IIII�t•IIII►, 2M10 1M507 REVISION 13 -01 BLDG. UPGRADE, SOUTH MEZZ. 782758 -05 UPGRADE 13 -01 782758 -21 BY C HARRAH C HARRAH t APPROVED P LAN SCALE: 1/8 " =1'- n SHOEMAKER SERIES 700MA -0 14x14 DIFFUSER W\ 8" NECK CFM AS NOTED (TYP 16 PLACES) DATE SYM REVISION BY APPROVED DATE 2M10 1M507 M99 -0004 0x10 RAJ JD LEGEND: 0 DIFFUSER N B — PO ...,.. � L za /tz 240 d 340 CFM ROUND DUCT, NUMBER IND CNTES D. "MITER SUPPLY OUTLET AIR DIFFUSER /REGISTAR /" LL . P= =ER TC SHEET M1 A. Y EARTHQUAKE BRACING, SEE 4 -WAY EA H BRACNS, S=E ( 0` . GENERAL N )7.T;S: \� RETURN GRILL POINT OF CONNECTION FLEXIBLE DUCT WITH VOLUEPE DAMPER RECTANGULAR DUCT, FIRS '.;'JMBER INDICATES SIZE FOR SIDE = N. 1. ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. 2. ALL DUCTS WHOSE GREATEST DIMENS C "! IS 30 " OR LESS SHALL BE 24 GAUGE GALVEN I ZED EPEE' METAL 3. ALL DUCTS WHOSE LARGEST DIMENS IC': I S BETWEEN 31 " AND 54" SHALL BE 22 GAUGE G.- ._VA -N ! ZED SHEET METAL. 4, ALL DUCTS WHOSE LARGEST DIMENSI�'. I 55" AND 84" SHALL BE 20 GAUGE SHEET METAL. 5. ALL DUCTS WHOSE LARGEST D I MENS I C IS GREATER THAN 85" SHALL BE 18 GAUGE GALV" ZED SF-EET METAL. 6 . REINFORCE DUCTWORK EVERY 4FT , MA .4 AND SUPPORT EVERY BFT, MAX. 8. ALL SUPPLY DUCTS WITHIN THE BUI_ C N S SHALL BE WRAPPED WITH 2 "THICK, 5 ,CLINE DENSITY FIBER GLASS INSULATION A F AN ALUMINUM FOIL FACE, REINFORCED F =IBER F I BER GLASS YARN MESH AND LAM I N. - EC - C F IRE RESISTANT KRAFT MANVILLE 800 SE= ES EP IN GLAS WITH FSK FACE, OR APPROVED EQUA_ 9, DIFFUSER SIZES INDICATED ARE NEC", S ES DIFFUSERS ARE 24 "X 24" T -BAR LA " —IN CONSTRUCTION NOTES RETURN REDLINED DRAWING SHOWING ANY DE`' .T 0 )5 FROM ORIGINAL DESIGN TO ENGINEER: CHUC'' M/S 46 -87, PHONE 655 -3003. INSTALL HVAC DUCTING SHOWN IN BOLD LINE= ATTACH TO EXISTING DUCTING B P.0.0.5 (E INSTALL DIFFUSERS AND FLEX DUCT I N EX IS NC- SHEETMETAL DUCTWORK AS SHOWN. USE 8 "0 SPIN I N COL .JRS P /DA.MPERS INSULATED FLEX DUCT, AND 2'x2' 4 -WAY D' (61 DIFFUSERS) INSTALL RETURN AIR REGISTERS WHERE SHOW' INSTALL DUCT HEATER. BALANCE AIR FLOWS PER CALLOUTS. _ DWG NO. 2M11 KEY VIEW SC NONE BETWEEN ZEE TELAC=S) RECEIVED CITY OF TUKWILA JAN 0 8 1999 PERMIT CENTER ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN C. HARRAH CHECKED ENGINEER CHECKED APPROVED DATE 8.1.98 SUBTITLE DUCTWORK TITLE BUILDING 13 -01 CURRENT REVISION JOB NO. 782758 -05 SYMBOL SHEET 2M10 DATE COMP ,_ —GB N B BY ' 'PPROVED D DATE S SYM R REVISION B BY A APPROVED D DATE A ACCEPTAB D C. HARRAH 8 DATE S SUBTITLE C CURRENT REVISION SYMBOL I I--� D DATE 1 782758 -05 H HURRAH T CHECKED —TO STRUCTURE r (lyP) !WORK (REF.) HANGER WIRE 26 GA GALV STRAP 2" WIDE -IN SUPPLY AIR DIFFUSER 6 STEEL CROSS BARS DES TO INTERIOR FRAME AND IL INTERSECTIONS, 6"OC FRAME ON ) WALL OPENING '4 "4 MIN SHT A WELD EXTERIOR TURE 2 PLACES 'UCTION FOR ROUND DUCT; IE, AND EXTERIOR FLANGE ; BE UNITED McGILL RRI IRON MANBAR DETAIL ( SCALE: NONE 1M507 INSULATED FLEX DUCT. SEE PLANS FOR SIZE CEILING GRID HANGER WIRE UP TO STRUCTURE. SEE ARCH /S ZUCT DWGS FOR SIZE & LOC'N (SYP) 1/4" SNAP –TIE LAY –IN CEILING TILE (TYP) ADJUSTABLE PATTERN CONTROLLERS NONE 2M 10,2M 10 1M507 EXTERIOR FRAME 1 1/2 "x1 1/2 "x3/16" ANGLE (TO FIT AROUND OUTSIDE OF DUCT) — INTERIOR FRAME 1 1/2 "x3/16" FLAT BAR (TO FIT SNUG INSIDE OF DUCT) 3/8" CARRIAGE BOLT 12" O.C. OR 2 PLACES MIN. EACH SIDE THRU INTERIOR FRAME, DUCT, & EXTERIOR FRAME. INSTALL W /BOLT HEAD ON INSIDE. DISTRESS THREADS AFTER ASSEMBLY. 1M507 FIRE SEPARATION SHEET METAL SLEEVE PER NPPA M507 EXISTING STRUCTURE MANBARS SEE DETAIL SECURITY BARS BOLT 22 GAUGE GALV, STRAPS. AROUND NEW OR EXISTING UNISTRUT CHANNEL AND ROUND OR RECTANGULAR DUCTWORK MOUNTING ANGLE PER NFPA SLIP JOINT, TYP. , ,.. -- SHEET METAL DUCT - -2" MIN (TYP) FIRE DAMPER TYPICAL FIRE DAMPER /SECURITY BAR DETAIL 2 SCALE: NONE 2M 1 O,2M 11 1 M507 2 7/16" UNISTRUT P5500 UNISTRUT P2381 -4 STUDNUT AND 1/2" NUT (TYP) 1M507 BOLT NEW MEMBER TO BOTTOM OR TOP OF EXISTING 6' -0" O.C. UNISTRUT MEMBER WITH UNISTRUT P2381 -4 STUDNUTS AND 1/2" NUT TO BOTTOM OR 1/2" A306 BOLTS, NUTS AND LOCK WASHERS ON TOP DETAIL - UNISTRUT DUCT SUPPORT ( 5 SCALE: NONE 1M1O,2M10,2M11 1M507 INSTALL 14 "x20" B PANEL OF IDENTICAL GAUG METAL AS DUCT, GLUE ALL EDGES OF SOUNDLINING WITH HARDCAST DUCT SEALER, ALLOW DUCT SEALER TO DRY COMPLETELY BEFORE SECURING PANEL WITH TEK SCREWS 4" ON CENTER AND FOAM GASKETING 0 DUCT HEIGHTS LESS THAN 14 ", MAKE PANEL HEIGHT 2" LESS THAN DUCT HEIGHT. EXISTING CONCRETE BEAMS BOLT 22 GAUGE GALV. STRAPS. AROUND NEW OR EXISTING UNISTRUT CHANNEL AND ROUND OR RECTANGULAR DUCTWORK CUT 12" HIGH BY 18" WIDE RECTANGULAR HOLE IN DUCT AND LINING 1 — LOW PRESSURE, RECTANGLAR INSULATED, DUCT NOTE; INSULATION CONTRACTOR TO MARK OUTLINE OF RECTANGULAR ACCESS PANEL WITH BLACK PERMANENT FELT TIP MARKER AND CROSS HATCH INTERIOR OUTLINE. 1/2" STUDNUTS AND NUTS TO FIT EXISTING UNISTRUT EMBEDDED IN CONCRETE BEAM (TYP) 1 5/8" UNISTRUT P5500 CHANNEL DETAIL - LOW PRESS. DUCT ACCESS PANEL ( 3 SCALE NONE 1 M507 1,M507 UNISTRUT P1047 "U" SHAPE FITTING WITH UNISTRUT P2381 -4 STUDNUT AND 1/2" NUT DETAIL - MED. PRESS. E/W DUCT HANGER SCALE: NONE 1M10,2M10 M507 mq oco q LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: RECEIVED CITY OF TUKWILA JAN 08 1999 PERMIT CENTER o- m {- COLD DECK P C BYPASS 12� ' ilk �j" �!RIv ► 7. $' • , 10 wallrelcfa`G7a7r " , / 1. VoLumE DAMPER f '' ' h � v�� (TYP) L 22/24 \ " �`� " , i , A L WI 1#4211114 .AIPAtitiagrilagrAl, A., a II PA, ,er 1•MIWZ411M, 4, THIS DUCT STAYS 35/12 THIS DUCT c STAYS . RETURN AIR FAN 1 1/4" HWR 1 1/4" HWS AIR VENT DETAIL SCALE: 1/4'=1'-D" DETAIL SCALE: 1/4"=1'-0" 25' -0" UPPER PLAN LOWER PLAN 7'- 6 "x3' -6" LOUVER 7' -6" SEE ARCH. SAT. A -7 FOR OPEN'S & LOUVER DET 2M10 M516 2M101M516 1'- 8"x5' -4" AUTO. RA. DAMPER ( 25' -0" � 5 / CONTINUATION ON SHT RFM60 3" CHWS - 7'- 6 "x3' -6" G.A. DAMPER THIS DUCT STAYS THIS DUCT STAYS SECTION SCALE: 1/4" =1•-0" THIS DUCT STAYS SECTION SCALE: 1/4''.-.1'-0" x M516 4" HWS M516 X X X VOLUME DAMPER (TYP) CEILING 18 "4 STACK 10 "4 STACK SEE DWG 206 FOR DETAIL OF STACKS AT ROOF 12"0 STACK 4" HWS MULTI — ZONE 10 SP MOTOR & 6.6 PD MOTOR SHEAVE FOR RPM INCREASED TO SEE DWG 206 FOR DETAIL OF STACKS THRU FLOOR . APPROVED DATE ® R R REMOVAL 13 -01 UPGRADES J #782758 -20 11-2-9 — -_— APPROVED R LIJ 3/4" HOSE BIBB DRAIN VALVE (TYPICAL) 3 —WAY AUTOMATIC MODULATING VALVE CHILLED WATER COIL UNION (TYPICAL) PETE'S XL PLUG (TYPICAL) 3 —WAY AUTOMATIC MODULATING VALVE 20/64 SECTION SCALE: 1/4"=1'-O" UNION VENT STRAINER CHILLED /HOT WATER COIL PETE'S XL PLUG (TYP.) CWR CWS HOT WATER COIL PIPING DETAIL SCALE: NONE M516 — PRESSURE GAUGE (TYPICAL) THERMOMETER (TYPICAL) VENT CWR n CWS 3/4" HOSE BIBB DRAIN VALVE (TYPICAL) CHILLED WATER COIL PIPING SCALE: NONE M516 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE APPROVED 1 0/29/98 TITLE MECHANICAL MASTER RELIEF AIR DAMPER CIRCUIT SETTER CALURATED BALANCED VALVE GATE VALVE OR BUTTERFLY VALVE BALANCING VALVE SEE FLOOR PLANS FOR CONTINUATION CIRCUIT SETTER BALANCING VALVE GATE VALVE OR �� BUTTERFLY VALVE BALANCING VALVE "DRAWN D. PRETARE CHECKED ENGINFAN CHECKED APPROVED SUBTITLE DETAILS - HEAT, VENT & AIR COND. BUILDING 13 -01 COL. 4a -5 /D -E 20/36 LEGEND GENERAL NOTES CONSTRUCTION NOTES REMOVE HOT WATER PIPING TO AIR HANC __E= A'8T. REWOVE PIPING BACK TO 4" MAINS ON EAST WAL_ TOC'M. REMOVE CHILLED WATER PAINS TO AIR -- _ ER UNIT. REMOVE CHILLED WATER PIPING BACK TO ROOF. D.I.3 1 M6OV FOR CHILLED WATER PIPE TERMINATION C • CUT —OFF 1 - 1/2" HWS &R AND CAP THE - _. ® CUT —OFF 1 -1/2" CHWS &R AND CAP TN REMOVE AIR HANDLING UNIT INCLUDING .7 _ WORK AS MARKED © REMOVE AIR HANDLING UNIT INCLUDING C _ WORK AS MARKED REMOVE THE ABANDONED CHILLER AND ASSOCIATED PIPING. fl MFC CURRENT REVISION SHEET JOB NO. SYMBOL M516R 782758 -20 DWG NO. 13- 01 -M516F RECEIVED CITY OP TUKWILA JAN 0 8 1999 PERMIT CENTER ZONE ;1 ZONE 2 - -- ZONE - #4- M VOLUME DAMPER (TYP) M516 M516 E7 I /I 35/12 - V_.J RETURN AIR FAN 1 1/4" HWR 1 1/4" HWS AIR VENT DETAIL SCALE: 1/4=1 DETAIL SCALE: 1/4"=1'-0" COLD DECK r BYPASS HOT DECK 25' -0" LOWER PLAN 25' -0" ATM A REWSION INSTALL VALVES /PIPING J #782758 -01 BY DMV 70/25 7'- 6 "x3' -6" LOUVER 7'- 6 "x3' -6" O.A. DAMPER 17' -6' SEE ARCH. SHT. A -7 F FOR OPEN'S & LOUVER DET UPPER PLAN CONTINUATION ON SHT RFM60 APPROVED (ZU�Y 2M10 M516 DATE 11 -2 -98 2M10 M516 1" CHWS 1" CHWR 12 "0 STACK 18 "0 STACK 10 "0 STACK 1'- 8 "x5' -4" AUTO. R.A. DAMPER SYM • r HWR () REVISION • � V.D. E 24/8 BY APPROVED SECTION SCALE: 1/4" =1' -0 SECTION SCALE: 1/4" =1' -0" DATE 25' -0" CHWSWR SEE CHW 3 " CHWR S t 1" PLAN! VIEW 70/26 ( CURB_- 1, 4" HWS M51 6 M516 3" HAS VOLUME DAMPER (TYP) CEILING 1J 18 "0 STACK 10 "0 STACK � 12 "0 STACK SEE DWG 206 FOR DETAIL OF STACKS AT ROOF 4" HWS MULTI - ZONE 10 HP MOTOR & 6.6 PD MOTOR SHEAVE FOR RPM INCREASED TO SEE DWG 206 FOR DETAIL OF STACKS THRU FLOOR 3/4" HOSE BIBB DRAIN VALVE (TYPICAL) 3 -WAY AUTOMATIC MODULATING VALVE CHILLED WATER COIL UNION (TYPICAL) PETE'S XL PLUG (TYPICAL) 3 -WAY AUTOMATIC MODULATING VALVE APPROVED WENT STRAINER TITLE UNION SECTION SCALE: 1/4"-1 0" PETE'S XL PLUG (TYP.) THERMOMETER (TYPICAL) VENT 3/4" HOSE BIBB DRAIN VALVE (TYPICAL) CHILLED /HOT WATER COIL CWR CWS HOT WATER COIL PIPING DETAIL SCALE: NONE M516 PRESSURE GAUGE (TYPICAL) CHILLED WATER COIL . PIPING SCALE: NONE M516 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. PRETARE CHECKED APPROVED DAIS 10/29/98 CHECKED NGIN RELIEF AIR DAMPER RETURN AIR FAN M516 CIRCUIT SETTER CALBRATED BALANCED VALVE GATE VALVE OR BUTTERFLY VALVE BALANCING VALVE SEE FLOOR PLANS FOR CONTINUATION CWS CIRCUIT SETTER BALANCING VALVE G ATE VALVE OR r_ BU TTERFLY VALVE BALANCING VALVE V.D.� fi SUBTITLE DETAILS - HEAT, VENT & AIR COND. BUILDING 13 -01 �4 LEGEND 20/36 GENERAL NOTES CONSTRUCTION NOTES D' INSTALL CHILLED BARER INLET & OUTLET AS •:C CA PROVIDE UNIONS TO THE 3 -WAY VALVE. SEE =_1-.L INSTALL HWS & NHS CONNECTIONS, UNIONS AND DRAIN POINTS. INSTALL HOT WATER 3 -WAY VALVE AND PROM :E ,;N C`:S FOR MAINTENANCE. . INSTALL CHILLED WATER VALVE AND PROi DE _ •0■0. PROVIDE AUTOMATIC AIR VENT AT THE H =H • - ISOLATION VALVE. TIE -IN EXISTING 1" CHWS &R TO NEW 3" CFH %S,%tF.. ® TAP 3" ABS FROM EXISTING 4" HWS. TAP 3" HWR FROM EXISTING 4" HWR. PROVIDE HOSE BIBB DRAIN FOR GARDEN HC, E= CON`: =CTIO'1 NOTE: SEE DETAIL FOR ISOMETRIC ON CAR'A. F't! RHO & HWR CONNECTION. INSTALL GAYLORD 3 -DECK MULTIZONE L'. __ PLACE JNIT PER DIMENSIONS. FABRICATE & INSTALL DISTRIBUTION PLC'.. E' : -_ =ER DRAWING. CONNECT TO EXISTING ZONE REPLACE EXISTING RETURN FAN WITH NE;. USE EXISTING TRAPEZE HANGERS. RECC:NE_ - -., 0 • EXISTING RETURN DUCTS. 14 FABRICATE AND INSTALL NEW DUCTING C FAN, RELIEF DAMPER, OUTSIDE AIR !NIA - HANDLING UNIT. INCLUDE RELIEF DAMPEF, AIR DAMPER AND OUTSIDE AIR DAMPER. qq- oop DWG N0. RECEIVED . - CITY OF TUKWILA JAN 0 a 1999 PERMIT CENTER OM.P •_.