Loading...
HomeMy WebLinkAboutPermit M99-0026 - AZTECA RESTAURANTM99 -0026 17555 Southcenter Pkwy. Azteca Restaurant City of Tukwila C Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: Type: Category: Address: 17555 SOUTHCENTER PY Location: Parcel #: 262304 -9134 Contractor License No: AMBIECC101PW TENANT OWNER CONTRACTOR CONTACT Print Name:__ M99 -0026 B -MECH NRES AZTECA RESTAURANT 17555 SOUTHCENTER PY, TUKWILA MBK NORTHWEST C/O TRAMMEL CROW COMPANY., AMBIENT CONTROL CO"INC 1020 S 344. ST, SUITE 203, BOB WALL:'. 1020 S 344 ST, SUITE 203, k* k*** k**** k***** ** *k * * **k * * *•k *•**k** * * * *•k * * ** Permit Description: INSTALL 2.5 TON GAS /ELECTRIC HVAC SYSTEM. UMC Edition: 1997 *****• k k ******************* *:* ************** * * * * *•k *•k * * *** ** * * * *•k * * * * *•k* Permit'Cente uthorized Signature I hereby certify that I have read and examined this permit and know the same to' be true and correct. All provisions of law and ordinances governing this work will .. be complied with, whether specified herein or not. The granting of this permit does not presume to give authority •to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature : D ate : ti p � �- WA 98188 WA Valuation: Total Permit Fee: `� I G 9 . Date . (206) 431-3670 Status: ISSUED Issued: 02/11/1999 Expires: 08/10/1999 Phone: 206 575 -8090 17560 SOUTHCENTER PY, TUKWILA WA 98188 Phone: 253 - 661 -5844 FEDERAL WAY WA 98003 Phone: 253 -661 -5844 FEDERAL WAY '98003 6,500.00 47.88 Title: This permit shall become null and, void if the work is not commenced within 180 days from the date._of issuance, or if the 'Work is suspended or abandoned for a period of 180 "days .from •the...last inspection. a Address: 17555 SOUTHCENTER PY Permit No: M99-0026 Suite: Tenant: AZTECA RESTAURANT Status: ISSUED . Type: B-MECH Applied: 01/26/1999 Parcel #: 262304-9134 Issued: 02/11/1999 It**k*Ak**Vick****Akk**k*Akk*AklAA Permi Land 1 t ions: 1. No changes will be made to the plans unless approved by the Arch i tect or Engineer and the_TuKw11,a Building Division. 2. All permi ts inspect ianWardi:W.Wnfkifvppoyed plans shall be available at the tpy00A4i--F5r any con- struct ion. These:.00 to ma iiitaTIQW,,and avail- able until f tp;f:itrispec tA,9'6 ‘P i s gran 3. All constru to be "(One In -confOrpande9i kth approved plans and ,reqU remetfts, of the Un iforni BuffalnaCode''.4:(1 Ed i t ion) 4S/ Un 1 form - Mithan i cal , Code (1997 Ea) el on) , and Washington State Energy Code (1997 Edition) ., 4. Val iditY.,Of Permit. The issuande:',of a permit or app riova'U of p I spec if icat ipns aWd:oomputii,fijons con- strued , to he a permit for. or an approval of , any violat Ion of ny of the provistoris of the bu i iding code or of other, 'ordinance of the jurisdiction. No permit presuming to velauthority ' to violate ,or cancel = the provisions ",of this code shall be valid; 5. MANUFACTURERS INSTALLATION ;INSTRUCTIONS REbU W IRED O SITE . ;' '' FOR HE BulLpING.MtPECTORSREVIEW:, 6. P1 Limb in§ Pe rml ts shalt'bef Obta ined thropgh the Seat t'le-K in County DeOrtmen t o1 Pub I I ,Hea 1 th. P1 umbing will be inspected by ,thatagency,' ud intj*-:a 11 gas piping (2964722) .4, 7 . El ept'r cal, ts sha 1 I be obeklIp.,cl 'throu the Wish jhg toni Stat Division of Labor and IndUst'n,i electrical workvl w.i 11. be nspected by that ageneY\ (2§-6630) - L . Read) access ible access to roof iiiountea:eq4A pmint v, , requined. CITY OF TUKWILA Project Name/Tenantt: / `� , 7 L - MC k�t Carl 1Qe,� J , frC( 6 1 of Construction: t7 t7 /.5 T f' rcel Nu ( b i er: V &.3 SL' 9- - q Si " c /� A _City tate/ ip: /S .1 S >dr r / ,- VC'/- t.,� /y / & » o Props y caner. /( ) B r � �� G 7 " 13 i `.' JC"S 1 �O �`ccti1w�� /l 62) Phone: ^ S �� g c7o Street Address: City State /Zip: Fax #: ---.. /D5 C <- „ -, , e .0,., >4,-- i•eielY / 4 FS' 1- Contact Person: _ ) b // Phone: .'s 6 (if r Street Address: . City State/Zip: Fax #: 3 .1" -gel - S - WS - :Eb t ,ocCa S 3 VY A S/ ?c13 7F/4/a„ 9196 Contractor: / -�-) �; r'�n� �,., l 69 _ � . Phone: _ ,53 — t; C/ , C /9 Street Address: City State /Zip: 0 • a i - d , - ,00 Fax #: _ f _ • . • Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax II: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) . . Description of work to be done: ��,s (( a 5 fir. s /E11°C 12---i ‘C ,/AI-e____ sys >i/� Will there be storage of flammable /combustible hazardous material in the building? ❑ yes �o Attach list of materials and storage location on se.arate 8 1/2 X 11 •a.er indicatin..uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks • Commercial Reroof ❑ Demolition ❑ Fence g Mechanical CI Manufactured Housing- Replacement only El Parking Lots El Retaining Walls Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO :: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt If ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous WATER METER DEPOSIT /REFUND BILLING: • Name: Address: Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 1 - 1 y' MISCPMT.DOC 7/11/96 CITY a T '/KWI LA Permit CenI r 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Da te application expires: 7 Fs STAFF USE ONLY PerrnIt;Number: PtoIttict Nuti'iuer: ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load /Hauling Apglicatlon taken by: (initials) BUILDING OWNS' EDAGENT Signature: ec I Date: aG _ p Print name: viPi.1 X et,4// X ° e L66 7 /3 - 0e/y G /-S F 3 6 1S!- �/ Address : /oa0 s, 3 y v A �.T Sh c*asialcii Er / Lf AL, , et.ir ,Z ri A SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR P PERMIT REVIEW Antennas /Satellite Dishes ` ` Submit chec , No': M 1 :' Awnings /Canopies' - No signage C Commercial Tenant Improverllent Permit ' Bulkhead /Dock S Submit checklist . No: M-10 0 C Commercial .Reroof S Submit checklist No: M - 6' 0 D Demolition S Submit checklist No; . :M 3,:1M -3a '' Fences- Over 6'feet in Height S Submit oheckiist No: M -9 in L Land Aitering/Grading/Preloads: S Submit checklist No: M -2 Loading Docks C Co Tenant` Improvement :, Permit ; ::Submit checklist No: H - 17 Mechanical (Residential`& Commercial) ' 'Submit Mi.,' M=8 : Residential only` H -6, H . 0 M Mis Wo . S Submit checklist' No; H9 0 M Manufactured ' Housing:(RED'INSiGNIA ONLY): S Submit checklist No: M -5 Moving.Oversied Load/Hauling S Submit checklist NO:.. M =5`. i P Parking Lots S Submit checklist No: M -4 • , ri R Residential Reroof - Exempt with following exception:; If roof structure R Residential Building Permit ,, Retaining Walls - Over 4'feet in height ' ' Submit: checklist ' No:•, M 1 Temporary Facilities S Submit checklist No: M in T Temporary` Pedestrian P'rotection/Exit'Systems . . Submit` checklist No ::. M =4`. a T Tree Cutting S Submit checklist No: ; M 2 . /I • • ► • • ICA IONS MUST BE SUBMITTED WITH THE FOLLOWING: ➢ ALL DRAWINGS SHALL(, AT A LEGIBLE SCALE AND NEATL ... RAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant Is other than the owner,, registered architect/englneer; ar `aantractor flcensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this, permit application and. obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 *JA• ** ** *,.•fr **hA * * *•A*•A * ** ** * i k lk A• ** *•k** *** * ****** •A * ** *4. **** *•A TfEfti +S MI:T' CITY t)F• TUKW.fl.A WA *.4***** * * *A•* **.* *4* * **:k,4 * *h * *****k••k,4A * ** ** **•A *A * *** *Aki** *•h, * * ** TRANSMIT Nurnb r••c •ft9JOOQ19 Amount.'.' 47.00 02/11/99 10;37 Payment Method: CHECK Ido,taitio'r AMBIENT CONTROL Ini TLN Pefrmit No:, M99 -002G .Type: II-MEC 1 MECHANICAL 'PERMIT Parcel No 26230A-913A S i t e Address: 17555 3OU1 HCI:NT ER f'Y Total Fees: This Payment 47.88 Total ALL E'nit61 A7).08. flalanc:ei ** *1%* * ** * ** •* * **Ia. ***,k4*It A * * *** ***k *,tit** ** t* ** *,fr* ****, *** Account Cod c r i pt i on A.maunt 000/345.830 (PLAN CHECK -• NONRES OOO/322. 100 MECHANICAL -:NONRES 9.58 30.:30'... Proje C/C6 T Y i err; . are-cn4l / Address [� (7 S-.---.9c- P(1 Special instructions: A Date w / m . Re• . '/ li( Phone: Inspe $47/REINSPECTION FEE REQUIRED. Prior to insp ction, fee must be paid at 6 00 Southcenter Blvd., Suite 100. Call to schedule reinspection, ; .• „� - Receipt No: Date: t I .. COMMENT INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO, 6 431 -3670 proved per applicable codes. 0 Corrections required prior to approval. COMMENTS: , , f ` , 1 ./41. — (icir / ,' CC;C 4 z 7 27 , x + e 7, f Address: / G5 _5: (4 �;T a dr t ( e C./ V7 " ( U*�1 a.m. Date g,./4 . p.m. l4t15 Phone: ,(/ 77 I/ %T ,c1/,,-,e 7 r " '7 , JW, ) ,k, 1/3 (J c g,_ r 1 ,. ...... ,•L -0', A •ifele . Iii /,((57, -c 707tie) _ Proj - _ %�� Ty Ins 4 Address: / G5 _5: (4 �;T Date cal .' Specia instructions: • a.m. Date g,./4 . p.m. Requ ster: ' Phone: : ry INSPCCTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188' Inspec Receipt No: INSPECTION RECORD Retain a copy with permit MIT NO. 6)431 -3670 0 Approved per applicable codes. prrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ?P l" 7) "(C ( c,.....c,.......- - Type of Ins ection:` 1 In-1 - i r�. <, dd es . Date caU peciai:instructions: Date wanted: wanted: ,cl a.m. p.m. Reque to : Phone; (o) - S f 2. INSPECTION RECORD Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 roved per applicable codes. 11 Corrections required prior to approval. COMMENTS: $47. ii REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • Project Name Authorized TNALAPP.FRM City of Tukwila Fire Department Needs shift inspection TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM fike, cAn./ / Address ) TS.( $/C 9/ a Retain current inspection schedule Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: r/ /fide../ t` 10 . 1 - C , Hood & Duct: V Halon: // Monitor: Pre -Fire: A/ Permits: M C/ 2 Permit No. Thomas P. Keefe, Are Chief John W. Rants, Mayor 4 . 2 f/ -- 002 �p Suite # 3/7 Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tu 1 ington 8188 • Phone: (206) 5754404 • Fax (206) 5754439 i v.cA Mgtusi.,wAL FILE C,OPY approvals FIN o(' 1 understand that and omissions and approval of a subleCt to errors and violation does not authorize, the nei of zap/ plans ordinance. Re Ledger(. adopted code or �1any �rGlcnow tr actor' S copy °f approved � By Date Permit O. OF r,ut t.A FP 0VFD i5.51i7a DIVISION 0 • , set 11 • • • 4 " PX )( 0 )(' unk INN" 0, VE.OTIOWLZ • -N., • •• •••1 • „•.:1 ;• • A •• • 4 15, ELEVAIIM 4. cei tj A • 4 . L it it .• ' t II 11 II II - .1I A • otELQ.clATE TO 1,06140 • lageiffit to 404EPULP)— Ns. 69) 0 2 L An Dasibirafi 7S Rolf'," • a /I' I' III ' 4 MODI YCC018F1LOB YCCO24F1L08 YCCO30F1LOB YCCO30F1MOB RATE' ' )LTS /PH /HZ 208. 230/1/60 208. 230/1/60 208. 230/1/60 208.230/1/60 A.R.I. INGS (COOLING)® BTUH 18000 23400 29200 29800 Indoor low (CFM) 600 800 1000 1000 System ver (KW) 1,93 2.55 3.17 3.27 EER /SI ' (BTU /WAIT -HR.) 9,35 / 10.00 9.10 / 10.00 9.20 / 10.00 9.10 / 10.00 Noise II-' No. 8,0 8.0 8.0 8.0 A,G.A ' 'WINGS (HEATING /0) (High) It BTUH 50000 50000 50000 75000 acity BTUHu®3 40000 40000 40000 60000 ' lE 78% 78% 78% 78% Temp. • °F (Min. /Max.) 30 / 60 30 / 60 30 / 60 35 / 65 (Low) I rtBTUII 400(10 40000 40000 60000 acity BTUHcIn® 32000 32000 32000 48000 t IE /CSE 78 %/76% 78 %/76% 78 %/76% 78%/76% Temp. ' 11 (Min. /Max.) 30 - 60 30.60 30 - 60 35 - 65 Typo r I rst NATURAL NATURAL NATURAL NATURAL POW' I':ONNS.- V /PH /HZ 208- 230/1/60 208-230/1/60 208. 230/1/60 208. 230/1/60 Min. I I Cir. Ampocil 13.2 15.7 20.1 21,3 Br. Ci' Max, (Amps) 20 25 30 35 Prot.' 'r - Recmd, (Amps) 20 25 30 35 COM I SSOR CLIMATUFF'" CLIMATUFF'" CLIMATUFF'" CLIMATUFF'" No. U 'I 1 1 1 1 Volts/ 'I IZ 200-230/1/60 200. 230/1/60 200 - 230/1/60 200-230/1/60 R.L , • - L.R.Amps 8.0 -48 10.0 -67 13.3 -79 13.5 -79 OUTI 'I''1 COIL - TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows I '.I. 2/15 2/15 2/15 2/15 Face ' , (Sq. Ft.) 4.5 4.5 5.43 5,43 Tube in.) 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER INDO 't :011 - TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows I '.I. 2/15 3/15 3/15 3/15 Face (Sq. Ft.) 3.25 3.25 3.25 3.98 Tubo : ' , ii.) 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER Refrip Control CAPILLARY CAPILLARY CAPILLARY CAPILLARY Drain I. Site (in.) 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT Duct ', , actions SEE OUTLINE DRAWING SEE OUTLINE DRINKING SEE OUTLINE DRAWING SEE OUTLINE DRAWING OUTI '' R FAN - TYPE PROPELLER PROPELLER PROPELLER PROPELLER No, U: , ' /Die,(in.) 1/18 1/18 1/18 1 /18 Type U. ■ e / No. Speeds DIRECT / 1 DIRECT / 1 DIRECT / 1 DIRECT / 1 No. Mini -HP 1 -1/5 1 -1/5 1 -1/5 1 -1/5 Motor '1 ed R.P.M. 1080 1080 1080 1080 Volts /I IIZ 200-230/1/60 230/1/60 230/1/60 230/1/60 F.L. An''• L.R.Amps 1.6 -3.3 1,6 -3.3 1.6 -3.3 1,6 -3.3 INOOOP rAN - TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Dia.xV.' ill (in.) 9X9 9X9 9X9 10X9 No. Used 1 1 1 1 Drive / St weds (No.) DIRECT / 2 DIRECT / 2 DIRECT / 2 DIRECT / 2 No. Maw; -HP 1- 1/4 1- 1/4 1- 1/4 1- 1/3 Motor Sp' R.P.M. 1080 1080 1080 1080 Volts /' II1lIZ 200-230/1/60 200-230/1/60 200-230/1/60 200. 230/1/60 F.L. A'ir - L.R. Amps 1.6/1.4 - 2,9 1.6/1.4 - 2.9 1.6/1.4 - 2.9 2.8/2.2 - 5.1 COM'IU "?ION FAN - TYPE CENTRIFUGAL CEN1RIFUGAL CENTRIFUGAL CENTRIFUGAL Drive - ' peels (No.) DIRECT - 1 DIRECT - 1 DIRECT - 1 OIREC F - 1 Moto III' - Speed (RPM) 1/35 - 3480 1/35 - 3480 1/35 - 3480 1/35 - 3480 Volts 'II /IIZ 240/1/60 240/1/60 240/1/60 240/1/60 F.L. „pr 0.6 0.6 0.6 0.6 FILTI I - FURNISHED? NO NO NO NO Type I ^n mended THROWAWAY THROWAWAY THROWAWAY THROWAWAY Min. I my Area -Lo (It.)r1,:1, 2.0 2.87 3,33 3.33 REFRIRF RANT Chang'' (IL's. of R -22)1 3.8 lbs. 4.0 lbs. 4.4 lbs. 4,5 lbs. GAS 'II'r. SIZE (IN.) 1/2" 1/2" 1/2" 1/2" DIM' 'ISIONS Crate (in ) Uncrr' oil WEII.III Shiprul 1 bs,) / Net (lbs.) 341 / 301 350 / 310 See n'tes on page 14 8 IIXWXD 31.1/4X38X57 SEE UUILINE DRAWING General Data HXWXD 31.1/4 X 38 X 57 SEE OUTLINE DRAWING IIXWXD 31.1/4X38X57 SEE OUTLINE DRAWING 398 / 358 HXWXD 35-1/4 X 38 X 57 SEE OUTLINE DRAWING 398 / 358 0 ( Performance Data duoling meow. In"..,..,. W: YCC018F --B AT 600 CFM (CAPACITIES ARE NET IN BTUH /1000 - INDOOR FAN HEAT DEDUCTED) 0.0. 1.0. TOTAL SENS, CAP. AT ENTERING D.B. TEMP. COMPR. APP.DEW D.B. W.B. CAP. 72 74 76 78 80 KW PT. CORRECTION FACTORS - OTHER AIRFLOWS 59 15.7 12.4 13.4 14.4 15.4 16.0' 1.28 45.6 (multiply or add as Indicated) 85 63 17.0 10.5 11.5 12.5 13.5 14.5 1.30 49.3 AIRFLOW 525 675 87 18.4 8.4 9.4 10.4 11.4 12.4 1.33 53.3 TOTAL CAP. X0.98 X1.02 71 19.8 6.2 7.2 8.2 9.2 10.2 1.35 57.4 SENS. CAP. X0.94 X1.05 59 15.6 12.4 13.4 14.4 15.4 15.9' 1.35 45.7 COMPR. KW X0.99 X1.01 90 63 16.9 10.4 11.4 12.4 13.4 14.4 1.37 49.5 A.D.P. -1.6 F 1.3 87 18.2 8.3 9.3 10.3 11.3 12.3 1.39 53.5 71 19.6 6.1 7.1 8.1 9.1 10.1 1.41 57.7 VALUES ATARI RATING CONDITIONS 59 15.5 12.3 13.3 14.3 15.3 15.8' 1.42 45.8 95 63 16.7 10.4 11.4 12.4 13.4 14.4 1.43 49.6 67 18.0 8.2 9.2 10.2 112 12.2 1.45 53.7 71 19.3 6.0 7.0 0.0 9.0 10.0 1.47 57.9 59 15.2 12.2 13.2 14.2 15.2' 15.6' 1.49 46.1 100 63 16.4 10.2 11.2 12 2 13.2 14.2 1.50 49.9 67 17.6 8.1 9.1 10.1 11.1 12.1 1.52 54.0 71 18.9 5.8 6.B 7.8 8.8 9.8 1.53 58.3 59 14.9 12.1 13.1 14.1 15.0' 15.4' 1.57 46.3 105 63 16.1 10.1 11.1 12.1 13.1 14.1 1.58 50.2 67 17.3 7.9 8.9 9.9 10.9 11.9 1.58 54.4 71 18.5 5.7 6.7 7.7 8.7 9.7 1.59 58.6 59 14.4 11.8 12.8 13 8 14.6' 14.9' 1.73 46.9 115 63 15.4 9.9 10.9 11.9 12.9 13.9 1.72 50.8 67 16.5 7.6 8.6 9.6 10.6 11.6 1.72 55.1 71 17.7 5.4 6.4 7.4 8.4 9.4 1.72 59.3 YCCO24F -B AT 800 CFM (CAPACITIES A 1E NET IN BTUH /1000 - INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENT El ING D.B. TEMP. COMPR. APP.DEW CORRECTION FACTORS OTHER AIRFLOWS D.B. W.B. CAP. 72 74 76 78 80 KW PT. (multiply or add as indicated) 59 20.7 17.0 18.5 19.9 21.0' 21.5' 1.72 46.8 85 63 22.4 14.3 15.7 17.2 18.6 20.0 1.77 50.6 AIRFLOW 700 900 67 24.3 11.2 12.7 14 1 15.5 17.0 1.83 54.7 TOTAL CAP. X0.98 X1.01 71 26.2 8.1 9.5 11 0 12.4 13.9 1.89 58.8 SENS. CAP. X0.94 X1.06 59 20.3 16.9 18.3 19 8 20.7' 21.2' 1.80 47.0 COMPR. KW X0.99 X1.01 90 63 22.0 14.1 15.6 17.0 18.4 19.9 1.85 50.8 A.D.P. -1.3 1- 1.1 67 23.8 11.0 12.5 13.9 15.4 16.8 1.91 54.9 71 25.7 7.9 9.4 10.0 12.2 13.7 1.97 59.1 VALUES ATARI RATING CONDITIONS 59 20.0 16.7 18.2 19 6 20.4' 20.9' 1.87 47.2 95 63 21.7 14.0 15.4 16 8 18.3 19.7 1.93 51.1 67 23.4 10.9 12.3 13 0 15.2 16.6 1.99 55.2 71 25.2 7.7 9.2 10 6 12.1 13.5 2.05 59.4 59 19.5 16.5 18.0 19 4 20.0' 20.5' 1.96 47.6 100 63 21.1 13.7 15.2 16 6 18.0 19.5 2.02 51,4 87 22.8 10.6 12.1 13 5 15.0 16.4 2.08 55.6 71 24.5 7.5 8.9 10 4 11.8 13.3 2.14 59.8 59 19.0 16.3 17.7 19 1' 19.6' 20.1' 2.05 47.9 105 63 20.6 13.5 14.9 16 4 17.8 19.3 2.10 51.8 67 22.2 10.4 11.9 13 3 14.7 16.2 2.17 55.9 71 23.9 7.3 8.7 10.1 11.6 13.0 2.23 60.2 59 18.0 15.9 17.3 18 3' 18.8' 19.2' 2.22 48.5 115 63 19.4 13.1 14.5 15.9 17.4 18.8 2.20 52.4 67 21.0 10.0 11.4 12 8 14.3 15.7 2.34 56.6 71 22.5 6.8 8.2 9.7 11.1 12.6 2.41 60.9 YCCO30F1LOB AT 1000 CFM (CAPACITIES AIIE NET IN BTUH /1000 - INDOOR FAN HEAT DEDUCTED) 59 25.0 20.9 22.7 24.5 25.5' 26.2' 2.41 47.3 95 63 27.1 17.5 19.3 21.1 22.8 24.6 2.50 51.1 67 29.2 13.7 15.5 17.3 19.0 20.8 2.58 55.2 71 31.4 9.9 11.6 13.4 15.2 16.9 2.67 59.4 59 24.4 20.7 22.4 24.2 25.0' 25.7' 2.54 47.6 100 03 26.4 17.3 19.0 20.8 22.5 24.3 2.62 51.4 67 28.5 13.5 15.2 17.0 18.8 20.5 2.71 55.6 71 30.6 9.6 11.3 13.1 14.9 16.6 2.80 59.8 59 23.8 20.4 22.2 23.9' 24.5' 25.2' 2.68 47.9 105 63 25.8 17.0 18.8 20.5 22.3 24.0 2.75 51.8 67 27.8 13.2 14.9 16.7 18.5 20.2 2.83 55.9 71 29.8 9.3 11.1 12.8 14.6 16.4 2.92 60.1 59 22.6 19.9 21.7 23.0' 23.6' 24.1' 2.92 48.6 115 63 24.4 16.5 18.2 20.0 21.7 23.5 3.01 52.4 67 26.3 12.6 14.4 16.2 17.9 19.7 3.09 56.6 71 28.3 8.7 10.5 12.3 14.0 15.8 3.17 60.9 TOTAL NET CAPACITY ' 18000 BTUH AIRFLOW - 600 CFM APP. DEW PT. - 53.7 DEG. F COMPRESSOR POWER - 1450 WATTS I.D. FAN POWER •= 220 WATTS 0.D. FAN POWER =- 260 WATTS S.E.E.R. - 10.00 BTUFI /WATT • DRY COIL CONDITION (TOTAL CAPACITY = SENSI- BLE CAPACITY) TOTAL CAPACIT Y,COMP. KW AND APP. DEW PT, ARE VALID ONLY FOR ALL TEMPERATURES IN DEGREES F. TOTAL NET CAPACITY - 23400 BTUH AIRFLOW - 800 CFM APP. DEW PT. - 55.2 DEG. F COMPRESSOR POWER = 1990 WATTS I.D. FAN POWER 300 WATTS O.D. FAN POWER - 260 WATTS S.E.E.R. - 10.00 BTUH /WATT • DRY COIL CONDITION (TOTAL CAPACITY =- SENSI- BLE CAPACITY TOTAL CAPACITY,COMP. KW AND APP. DEW PT, ARE VALID ONLY FOR ALL TEMPERATURES IN DEGREES F. O.D. 1.0. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. APP.DEW CORRECTION FACTORS •OTHER AIRFLOWS D.B. W.B. CAP. 72 74 76 78 80 KW PT. 59 25.9 21.4 23.1 24 9 26.3' 27.0' 2.20 46.7 (multiply or add as Indicated) 85 63 28.1 18.0 19.7 21.5 23.3 25.0 2.28 50.5 AIRFLOW 875 1125 67 30.4 14.2 16.0 17.7 19.5 21.3 2.37 54.6 TOTAL CAP. X0.98 X1.01 71 32.7 10.3 12.1 13.9 15.6 17.4 2.45 50.8 SENS. CAP. X0.94 X1.05 59 25.5 21.1 22.9 24.7 25.9' 26.6' 2.31 47.0 COMPR, KW X0.99 X1.01 90 63 27.6 17.7 19.5 21.3 23.0 24.8 2.39 50.8 A.D.P. -1,4 + 1.1 67 29.8 14.0 15.7 17.5 19.3 21.0 2.47 54.9 71 32.1 10.1 11.9 13.6 15.4 17.2 2.56 59.1 VALUES ATARI RATING CONDITIONS TOTAL NET CAPACITY - 29200 BTUH AIRFLOW m 1000 CFM APP. DEW PT. :s 55.2 DEG. F COMPRESSOR POWER - 2580 WATTS I.D. FAN POWER ^ 340 WATTS O.D. FAN POWER - 250 WATTS S.E.E.R. - 10.00 BTUH /WATT ' DRY COIL CONDITION (TOTAL CAPACITY - SENSI- BLE CAPACITY TOTAL CAPACI Y,COMP. KW AND APP, DEW PT. ARE VALID ONLY FOR • ALL TEMPERATURES IN DEGREES F. 15 AIRFLOW CFM1 HIGI I SPEED I PRESS. IN. W.G. PWR. WATTS BHP 800 0.62 300 0,26 850 0.60 308 0.27 900 0.68 318 0.28 950 0.54 331 0.29 1000 0.50 343 0.30 1050 0.42 354 0.31 1100 0.35 365 0.32 1160 0.27 378 0.33 1200 0.19 392 0.34 1250' 0.07 408 0.35 0.61 415 0.33 0.48 400 0.32 1050 0.58 423 0.34 0.43 410 0.33 1100 0.54 432 015 0.37 422 0.34 1150 0.5 441 0.35 0.31 435 0.35 1200 '1 FACTORY SETTING AT HI SPEED r WATER BLOW -OFF LIMIT l ' t'i'ET LCNL. t AIRFLOW CFM' HIGH SPEED LOW SPEED i' PRESS. IN. W.G. PWR. WATTS BIIP PRESS IN. W.G. PWR. WATTS BHP 750 0.79 378 0.30 0.7 355 0.28 800 0.76 385 0.31 0.66 363 0.29 850 0.72 392 0.31 0.62 371 0.30 900 0.69 399 0.32 0.56 380 0.30 950 0.65 407 0.33 0.53 390 0.31 1000 0.61 415 0.33 0.48 400 0.32 1050 0.58 423 0.34 0.43 410 0.33 1100 0.54 432 015 0.37 422 0.34 1150 0.5 441 0.35 0.31 435 0.35 1200 0.45 450 0.36 0.25 449 0.36 1260 0.41 460 0.37 0.17 464 0.37 - - - 1000 0.37 323 0.26 - - - .1, FACTORY SETTING AT HI SPEED $ WATER BLOW -OFF LIMIT t WET COIL, NO FILTER 1 FACTORY SETTING AT LOW SPEED .1 WET COIL, NO FILTER •t FACTORY SETTING AT LOW SPEED m • Tn I_ tIC, c LT co AIRFLOW CFM' IIIGI I SPEED LOW SPEED PRESS. IN W.G. PWR WATTS BHP PRESS IN. W.G. PWR. WATTS BHP 450 0.77 220 0.18 0.67 168 0.13 475 0.75 224 0.18 0.65 172 0.14 500 0.74 227 0.18 0.63 175 0.14 525 0.72 231 0.16 0.61 179 0.14 550 0.7 234 0.19 0.58 182 0.15 575 0.69 238 0.19 0.55 186 0.15 600 0.67 242 0.19 0.53 190 0.15 625 0.66 247 0.20 0.49 194 0.16 650 - t11G 0 64 00 :' 0 6 0 SI) 010 252. ..1.0 0.20 0:U (1 2. 1 U I II ,L2 0.46 0.. (1 ;1 0 3.1 II 2t) 198 0: 2(1(i . ./1 I Glti 0.16 010 0 10 1 1 U I / 1(1(1 ' ^Ii lbll 2(11 ^1lll 2I11 950 0.41 312 0.25 - - - 975 0.39 317 0.25 - - - 1000 0.37 323 0.26 - - - .1, FACTORY SETTING AT HI SPEED $ WATER BLOW -OFF LIMIT t WET COIL, NO FILTER 1 FACTORY SETTING AT LOW SPEED .1 WET COIL, NO FILTER AIRFLOW CFMt IIIGH SPEED.!' LOW SPEED PRESS. IN. W.G. PWR. WATTS BHP PRESS IN. W.G. PWR. WATTS BHP 600 0.67 242 0.19 0.53 190 0.15 625 0.66 247 0.20 0.49 194 0.18 650 0.64 252 0.20 0.46 198 0.18 675 0.82 256 0.20 0.42 202 0.16 700 0.6 261 0,21 0.38 206 0.16 725 0.59 266 0.21 0.33 211 0.17 750 0.57 270 0.22 0.26 216 0.17_ 775 0.55 275 0.22 - - - 600 11141 11'(t ._.. . 000, 925 0.53 II 411 11411 a 6 • 0.44 280 0.22 (I :,l It:.$ tt . t 0.24 - - :11(1 ;111v i‘ 306 950 0.41 312 0.25 - - - 975 0.39 317 0.25 - - - 1000 0.37 323 0.26 - - - .1, FACTORY SETTING AT HI SPEED $ WATER BLOW -OFF LIMIT t WET COIL, NO FILTER Indoor Fan Performance YCC018F -L External Static Pressure From Dwg. 21A730145 Rev. 0 Indoor Fan Performance YCCO30F -M External Static Pressure From Dwg. 21A 730241 Rev. 0 Performance Data Indoor Fan Performance YCCO24F -L External Static Pressure From Dwg. 21A730239 Rev. 0 Indoor Fan Performance YCCO30F1 LOB External Static Pressure From Dwg. 21A68 15 79 Rov. 19 Side Distance (In.) Bottom 0.0 Back (Duct) 1.0 Left 6.0 Right 6.0 Front 12.0 Top 36.0 SERVICE CLEARANCE DIMENSIONS MODEL NO. A B C D YCC018- 036F -L YCCO30,036F -M 2'6" 2'6" 6 "• 2'0" MODELS AIR DUCT OPENINGS A B C D YCC018.038F -L YCCO30,036F•M Supply Duct 21 11.1/4 — — Return Duct — — 11.1/2 181/8 (All dimensions are in inches) 32 SERVICE CLEARANCE LINES SIDE RAIL I'8' with 25% Fresh air accessory 2'6' with Economizer WOOD NAILER Dimensional Data coc BAYCURB030 Roof Mounting Curb Outline YCC018 -036F— Units Required Clearance for Unit Installation and Roof Penetration Hole Size Required `\ SERVICE CLEARANCE LINES From Dwg. 210729942 Rev. 2 Clearance From Combustible Materials From Dwg, 210662114 Rev, 0 01' MODEL A 6 C 0 E F YCC018 /024F -L YCCO30F•L 55.1/4 36 25.3/16 12.15/16 36-3/4 KNOCKOUTS FOR 1/2' AND I' CONDUIT YCCO30f•M YCCO36F•L /F•M 55.1/4 36 29 -3/10 12.16/16 363/4 KNOCKOUTS FOR 3 /4' AND 1.1 /4'CONDUIT YCCO36F•11 YCC042F•M YCC048F•M 62.3/4 36 29.3/16 14.1/2 27.1/2 KNOCKOUTS FOR 3/4 AND 1.1/4' CONDUIT YCC060F•M 64.5/16 45 33.3/8 14 -13/16 27.15/16 KNOCKOUTS FOR 3 /4' AND 1.1 /2'CONDUIT CONTROL BOX ACCESS PANEL — F HOLE FOR 1/2" CONDUIT (UNIT CONTROL WIRES) C.. Dimensional Data YCC018 -060F Outline — Front (ALL DIMENSIONS ARE IN INCHES) 1" DIAMETER K,O. FOR 1/2 N.P.T. GAS CONNECTION AS VALVE ACCESS CONDENSER COIL IN THIS AREA ONLY ON YCC042F -M, YCC04Er -M ONDENSER COIL C From Dwg. 21D661689 Rev. 0 37 CABINET MODEL CORNER WEIGHTIL851 UNIT WEIGHT INET LBS.) A 6 C 0 E F G H J K L M N P W1 W2 W3 W4 A YCC018F•1 68 3 61.1 84 92.9 307 551/4 36 25.3/16 18.9/16 11.1/18 69/16 6.13/16 17 21.5/16 25 171/2 10 3 4.7/16 YCCO24F.1 69.4 60 0 85 99.6 314 YCCO30F•L 70.5 61.4 87 99 8 319 8 YCCO36FL 8406 6808 92.1 113.7 358 55.1/4 36 29 3/16 189/16 11.1/16 6.9/16 6.13/l6 17 203/4 25.13/16 17.1/2 10 3 4.1/16 YCCO30F M 78.3 68 3 95.6 109.7 352 19.3/4 24.13/18 YCCO36F-M 86 67 6 93 2 115.13 364 C YCCO361•11 90 3 73 8 101 123.7 389 62.3/4 36 29.3/16 189/16 11.1/16 15.1/18 6 9/16 4.15/16 11.1/8 9.1/8 17 21.15/16 193/4 28-1/4 17.1/2 20 10 14 3 3.1/2 8.3/4 8.5/16 YCC042F-M 103.7 88 7 96 8 122 6 412 19.3/4 28.1/4 YCC048F•M 104.6 84 6 102.2 126.4 410 19.3/4 25 28.1/4 29.1/2 0 YCC048F11 123 8 104 8 132.5 157 518 64.5/16 45 33.3/8 21-1/16 YCC06 -M 1354 1098 137.3 169.3 552 25 29.112 38 C HORIZONTAL. SUPPLY OPENING DOWNFLOW SUPPLY OPENING HORIZONTAL RETURN OPENING SECT. X -X TYPICAL CROSS SECTION OF SUPPLY & RETURN PERIMETER FLANGES APPEARANCE SURFACE OF SUPPLY & RETURN PANEL Dimensional Dat,- and Weights ( YCC018 -060F Outline - Rear (ALL DIMENSIONS ARE IN INCHES) L k M DIMENSIONAL SURFACE ISEE TABLEI 1 CONDENSATE DRAIN FOR 3 \4" FEMALE NPT DOWNFLOW RETURN OPENING i SECT Y -Y TYPICAL CROSS SECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES EVAPORATOR COIL & BLOWER PANEL 2 11 DIA. ENTRY FOR 1/2 N.P.T. GAS CONNECTION From Dwg. 21D861690 Rev. 1 Fan Equipment Schedule Equip, ID Brand Name' Model No,' CFM SP' HP/BHP Flow Control Location of Service Location / /rnh e. Y6LoWF1Lo& 2 i /ex) o i0 iZ t) Fo RECEIVED TY of T UKWILA r 0 t 3 ERtlIT CENTER Cooling Equipment Schedule Equip, ID Brand Name' Model No.' Capacity' Total CFM OSA CFM Econo SEER or EER IPLV' Location / /rnh e. Y6LoWF1Lo& 2 i /ex) o i0 iZ t) Fo r Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity' Total CFM OSA cfm Econo Input With Output Btuh Efficiency' / 7i-rr fri C�- Ye 403 OF/4) 73 'a .S"'" / ex) v j72, )i) iZ t) Fo Project Info Project Address + Date 75 "` C e= r ,, For Building Dept. Use - Tukt,t>; la , (4/ t+ Applicant Name: h (rn - h I cc) . �r,`er�� r 4 L. Applicant Address:' 0Af7 s. •-S c V7it .cX 57 ;RO3 Applicant Phone: / - S cy .66 Mechanical Sunni . ry MECH -SUM 1997 Washington Stale Nonresident's' Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. -17.,s 1( r.e -'-t2 a c"" - Jo. - . 6-c!5/ /'c. Pcrl'rccly w i ti of 1\ r ei e - 'k0? dd c tc`}- tk cj Cif" titeuti a J . Compliance Option Equipment Schedules 1997 .",In.ton State Nonresidential Ener. Code Comnilance Form Simple System ❑ Complex System ❑ Systems Analysis (See Decision Flowchart (over) for qualifications) The following information Is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Rd Edition • June 1999 'If available, ' As tested according to Table 14 -1, 14 -2 or 14 -3. ' If required. ' COP, HSPF, Combustion Efficiency, or AFUE, as applicable. Flow control types: VAV, constant volume, or variable speed. PleN System Description See Section 1421 for full description of Simple System qualifications, If Heating/Cooling or Cooling Only: ❑ Constant vof? CI spilt system? ❑ Alr cooled? af ackaged sys? ❑ Economizer Included? 54,000 Btuh or 1900 dm? ff Healing Only: ❑ <5000 cfm? ❑ <70% outside air? 1997 Washington Slate Nonresidential Energy Code Compliance Forms 1997 Wash ^ton State Nonresidential Ener Code Com'll: °•14 Form Mechanical Summa (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Start System Type 5000 dm <70% OA <54,000 Btut 1900 dm 'onstant olurne Split stem? 84,000 Btu 2800 cfm ackage. yes * slam no Reference Sec. 1423 r Cooled? Staple System Allowed Use Complex Reference System Sec. 1430 Heating Only no no eatlnq Goodall or Cooling Only ( Reference Sec. 1421 Fri Includes Econo ? no yes yes Reference Sec. 1420 1` no First Edition • June 1998 Complex Systems Refer to MECH -COMP Mechanical Complex Systems tor assistance in determining which Complex Systems requirements are applicable to this project. * ** AMBIENT CONTROL * ** 1020 SOUTH 344TH ST /' 203 FEDERAL WAY, WA \_,8003 QUICK COMMERCIAL HVAC LOADS PROGRAM CLIMATE DATA: DESIGN MONTH AUGUST JUNE JULY SEPTEMBER JANUARY FEBRUARY WINTER OUTDOOR DRY BULB 86 84 88 80 54 59 21 OUTDOOR WET BULB GENERAL PROJECT INFORMATION: 68 66 69 65 48 50 0 50% 50% 50% 50% 50% 50% 50% PROJECT FILE NAME: PROJECT LOCATION: BAROMETRIC PRESSURE: ALTITUDE: NORTH LATITUDE: MEAN DAILY TEMPERATURE RANGE: ATMOSPHERIC CLEARNESS FACTOR: GROUND REFLECTANCE: STARTING TIME FOR HVAC LOAD CALCULATIONS: ENDING TIME FOR HVAC LOAD CALCULATIONS: FLOOR HEAT LOSS COEFFICIENT: NUMBER OF UNIQUE ZONES IN THIS PROJECT: BUILDING DEFAULT VALUES: CALCULATIONS PERFORMED: LIGHTING REQUIREMENTS: EQUIPMENT REQUIREMENTS: PEOPLE SENSIBLE LOAD MULTIPLIER: PEOPLE LATENT LOAD MULTIPLIER: PEOPLE OCCUPANCY BASIS: ZONE SENSIBLE SAFETY FACTOR: ZONE LATENT SAFETY FACTOR: ZONE HEATING SAFETY FACTOR: PEOPLE DIVERSITY FACTOR: PROJECT: CLIEI" DATE DESIGNER: INDOOR INDOOR REL.HUM DRY BULB 75 75 75 75 75 75 75 A:AZTECASC Tukwila WA 29.491 IN.HG. 400 FEET 47 DEGREES 26 DEG.F 1 20 PERCENT 8 AM 12 AM 0.5 BTUH /FT -F 1 Azteca Southcenter Ambient Control Co. I. 01/25/99 GRAINS DIFF. 9.61 2.57 11.70 4.02 -24.90 -25.74 0.00 ALL DESIGN DATA TAKEN FROM THE 1989 ASHRAE HANDBOOK OF FUNDAMENTALS BOB WALL IN /OUTDOOR CORRECTION BOTH HEATING AND COOLING LOADS 1.00 WATTS PER SQUARE FOOT 0.50 WATTS PER SQUARE FOOT 245 BTU PER PERSON 155 BTU PER PERSON 1 PERSON PER 45 SQ.FT 10% 10% 10% 100% - 9 - 11 - 7 - 15 -41 - 36 ** QUICK COMMERCIAL HVAC LOADS AMBIENT CONTROL Azteca Southcenter `_. * * * * * * * * * * * * * * * * * * * * * * * * ** AIR AIR HANDLER # 1 INPUT DATA: AIR HANDLER DESCRIPTION: TERMINAL TYPE: SUPPLY FAN TYPE: CALCULATIONS PERFORMED: NUMBER OF TIMES SYSTEM OCCURS: LEAVING COOLING COIL TEMP. (DEG.F): LEAVING HEATING COIL TEMP. (DEG.F): COMBINED FAN,MOTOR EFFICIENCY ( %): STATIC PRESS. ACROSS FAN (IN W.G): SUMMER SUPPLY DUCT TEMP. RISE (DEG.F): SUMMER RETURN DUCT TEMP. RISE (DEG.F): WINTER SUPPLY DUCT TEMP. DROP (DEG.F): WINTER RETURN DUCT TEMP. DROP (DEG.F): CHILLED WATER TEMP.DIFFERENCE (DEG.F): HOT WATER TEMP.DIFFERENCE (DEG.F): COOLING VENTILATION METHOD: COOLING VENTILATION VALUE: COOLING INFILTRATION METHOD: COOLING INFILTRATION VALUE: HEATING VENTILATION METHOD: HEATING VENTILATION VALUE: HEATING INFILTRATION METHOD: HEATING INFILTRATION VALUE: VENTILATION IS 100% OF SUPPLY AIR: EQUIPMENT DATA BRAND: MODEL: TYPE: DESCRIPTION: EFFICIENCY: CAPACITY: BLOWER CFM: COMMENT: HEATING SYSTEM DESCRIPTION Brand X Model Number Furnace Upflow 92% AFUE 24000 Btuh 893 CFM Lifetime Warranty PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** FEDERAL WAY, WA 98003 01/25/99. PAGE 2 HANDLER INPUT DATA * * * * * * * * * * * * * * * * * * * * * * * * ** PACKAGED VARIABLE AIR VOLUME BUILT -IN PACKAGED UNIT BOTH HEATING AND COOLING LOADS 1 55 95 0 0.000 1.000 1.000 0.000 0.000 0.000 0.000 1 0.700 AIR CHANGES PER HOUR 0 0.000 2 5.000 CFM PER PERSON 0 0.000 NO COOLING SYSTEM DESCRIPTION Brand X Model Number Standard A/C 11 SEER 2.5 Tons 1027 CFM 5 Year Warranty ZONE # 1: ZONE 1 (616 SF) AIR HANDLER NUMBER: ZONE LENGTH (FEET): LIGHTING WATTS: DIRECT NO. OF PEOPLE IN ZONE: DIRECT CEILING HEIGHT (FEET): SEN.SAFETY FACTOR ( %): SEN.HEAT PER PERSON (BTU): CLG VENTILATION CFM: HTG VENTILATION CFM: CLG. SQFT EXPOSED TO PLENUM: LAT. BTUH EQUIP LOAD: ** QUICK COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** AMBIENT CONTROL Azteca Southcenter � .. 01/25/99 FEDERAL WAY, WA 98003 �... PAGE 3 * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ZONE INPUT DATA * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1 ZONE OCCURRENCES: 28.0 ZONE WIDTH (FEET): 500 EQUIPMENT WATTS: 22 EXHAUST AIR CFM: 10.0 HTG.SAFETY FACTOR ( %): 10 LAT.SAFETY FACTOR ( %): 245 LAT.HEAT PER PERSON (BTU): 0 CLG INFILTRATION CFM: 0 HTG INFILTRATION CFM: 616 EXPOSED FLOOR SLAB EDGE -FT: 0 HTG. & CLG. LOADS CALCULATED YES WALL 1 1 22.0 DIRECT 2000 0 10 10 155 0 0 0.0 ROOF ASHRAE # U- FACTOR LENGTH WIDTH ROOF -AREA SUSP.CEIL COLOR 1. 1 0.134 28.0 PART U- FACTOR COOL.T -D HEAT.T -D 1. 0.065 5 10 GLASS CONSTRUC U- FACTOR GLS.AREA SHD.COEF INT.SHADE REFERENCE 1. MEDIUM 0.610 40.0 0.390 22.0 616.0 NO DARK HEIGHT WIDTH PART -AREA 10.0 22.0 220.0 ** QUICK COMMERCIAL AMBIENT CONTROL Azteca Southcenter * * * * * * * * * * * * * * * * * ** LOAD DESCRIPTION 1. ZONE 1 SYS# 1 ROOF- 1- NO.CLG -D PARTITION LIGHTS EQUIPMENT PEOPLE TOTAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** Q. FEDERAL WAY, WA 98003 01/25/99 �. PAGE 4 DETAILED PROJECT ZONE LOAD CALCULATIONS * * * * * * * * * * * * * * ** UNIT -SC- CLTD U.FAC SEN. QUAN CFAC SHGF -CLF- GAIN LAT. HTG. HTG. GAIN MULT. LOSS PEAK TIME 2 PM JUL. (28 X 22) = 616 SF 616 1.000 72 220 5/10 500.00 1.000 100% 2000.00 1.000 22.00 1.000 0.134 0.065 3.410 3.410 245/155 5943 7.236 4457 72 0.650 143 1705 6820 0 5390 3410 19,930 3,410 4,600 X 1.10 X 1.10 X 1.10 21,923 3,751 5,060 ** QUICK COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** AMBIENT CONTROL / FEDERAL WAY, WA 98003 4zteca Southcenter C� ..- 01/25/99 l...,' PAGE 5 * * * * * * * * * * * * * * * * * * * * * ** AIR SYSTEM # 1 ZONE SUMMARY * * * * * * * * * * * * * * * * * * * * * * ** ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CFM NO. PEAK TIME & MONTH AREA O.A. CFM O.A. CFM EXH. CFM CFM /SF. CFM /SF. 1 ZONE 1 2 PM JULY ZONE PEAK TOTALS 616 TOTAL ZONES: 1 616 5,060 21,923 110 72 5,060 21,923 110 72 3,751 238 1,064 0 0.39 1.73 3,751 238 1,064 0 0.39 1.73 ** QUICK COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** AMBIENT CONTROL FEDERAL WAY, WA 98003 Izteca Southcenter C. 01/25/99 ( PAGE 6 * * * * * * * * * * * * * * * * * * ** AIR SYSTEM # 1 TOTAL LOAD SUMMARY * * * * * * * * * * * * * * * * * * * ** AIR HANDLER DESC: PACKAGED WITH VAV TERMINALS SENSIBLE HEAT RATIO: 0.86 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING AIR SYSTEM PEAK TIME: 2 PM IN JULY OUTDOOR CONDITIONS: 87 DB, 69 WB, 78.91 GRAINS INSIDE: 75 DB, 50% RH SUMMER: VENT CONTROLS OUTSIDE AIR WINTER: VENT CONTROLS OUTSIDE AIR ZONE SPACE SEN.LOSS: INFILTRATION SEN.LOSS: OUTSIDE AIR SEN.LOSS: SUPPLY DUCT SEN.LOSS: RETURN DUCT SEN.LOSS: TOTAL SYSTEM SEN.LOSS: 11,383 BTUH SUPPLY AIR: 5,060 / (0.986 X 1.08 X 20) = ( WINTER VENT OUTSIDE AIR (46.28% OF SUPPLY): ZONE SPACE SEN.GAIN: INFILTRATION SEN.GAIN: DRAW -THRU FAN SEN.GAIN: SUPPLY DUCT SEN.GAIN: TOTAL SEN.GAIN ON SUPPLY SIDE OF COIL: 23,077 BTUH SUPPLY AIR: 23,077 / (0.986 X 1.1 X 20) = ( 1,064 CFM) SUMMER VENT OUTSIDE AIR (6.76% OF SUPPLY): ( 72 CFM) RETURN DUCT SEN.GAIN: RETURN PLENUM SEN.GAIN: OUTSIDE AIR SEN.GAIN: BLOW -THRU FAN SEN.GAIN: TOTAL SEN.GAIN ON RETURN SIDE OF COIL: 2,091 BTUH TOTAL SEN.GAIN ON AIR HANDLING SYSTEM: 25,168 BTUH ZONE SPACE LAT.GAIN: INFILTRATION LAT.GAIN: OUTSIDE AIR LAT.GAIN: 5,060 BTUH 0 BTUH 6,323 BTUH ( 0 BTUH 0 BTUH 21,923 BTUH 0 BTUH 0 BTUH 1,154 BTUH 1,154 BTUH 0 BTUH 937 BTUH ( 0 BTUH 3,751 BTUH 0 BTUH ( 643 BTUH ( TOTAL LAT.GAIN ON AIR HANDLING SYSTEM: TOTAL SYSTEM SENSIBLE AND LATENT GAIN: TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: 0 CFM) 110 CFM) 238 CFM) 110 CFM) 0 CFM) 72 CFM) 0 CFM) 72 CFM) 4,394 BTUH 29,562 BTUH 2.46 TONS ** QUICK COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** AMBIENT CONTROL ( FEDERAL WAY, WA 98003 Azteca Southcenter 4.. 01/25/99 PAGE 7 * * * * * * * * * * * * * * ** AIR SYSTEM # 1 ZONE SENSIBLE LOAD PROFILE * * * * * * * * * * * * * * * ** * * AUGUST * HOUR ZONE.SEN 1 AM 0 2 AM 0 3 AM 0 4 AM 0 5 AM 0 6 AM 0 7 AM 0 8 AM 15840 9 AM 17202 10 AM 18564 11 AM 19654 12 PM 20561 1 PM 21197 2 PM 21287 3 PM 21106 4 PM 20470 5 PM 19471 6 PM 18201 7 PM 16839 8 PM 15749 9 PM 15204 10 PM 14841 11 PM 14568 12 AM 14387 MONTHLY AND HOURLY SYSTEM # 1 ZONE SENSIBLE LOAD PROFILE JUNE ZONE.SEN 0 0 0 0 0 0 0 16293 17656 19018 20107 21016 21651 21742 21560 20924 19925 18655 17292 16203 15659 15294 15023 14841 JULY ZONE.SEN 0 0 0 0 0 0 0 16476 17838 19199 20288 21197 21833 21923 21742 21106 20107 18836 17475 16385 15840 15477 15204 15023 SEPTEMBER ZONE.SEN 0 0 0 0 0 0 0 14750 16112 17475 18564 19471 20107 20198 20017 19381 18382 17111 15749 14660 14114 13751 13479 13297 JANUARY ZONE.SEN 0 0 0 0 0 0 0 11300 12662 14024 15113 16022 16657 16748 16566 15930 14931 13661 12299 11209 10665 10302 10029 9847 FEBRUARY * ZONE.SEN * 0 0 0 0 0 0 0 12208 13570 14931 16022 16929 17565 17656 17475 16839 15840 14568 13207 12117 11572 11209 10936 10755 * ** QUICK COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** AMBIENT CONTROL / WAY, WA 98003 4zteca Southcenter C.. 01/25/99 - PAGE 8 * * * * * * * * * * * * * * * * ** AIR SYSTEM # 1 PSYCHROMETRIC ANALYSIS * * * * * * * * * * * * * * * * * ** SYSTEM LOAD ANALYSIS LEAVING COIL CONDITION DRAW -THRU FAN SUPPLY AIR DUCT ZONE LOADS ZONE CONDITION RETURN AIR DUCT RETURN AIR PLENUM VENTILATION AIR BLOW -THRU FAN ENTERING COIL CONDITION 72 CFM 60.339 3,751 5.259 3,751 65.597 643 0.901 GENERAL PSYCHROMETRIC EQUATIONS USED IN ANALYSIS: PR = (BAROMETRIC PRESSURE OF SITE / STANDARD ASHRAE PRESSURE OF 29.921) TSH = PR X 1.10 X CFM X (DB.ENTERING - DB.LEAVING) TLH = PR X 0.68 X CFM X (GRAINS.ENTERING - GRAINS.LEAVING) GTH = PR X 4.50 X CFM X (ENTHALPY.ENTERING - ENTHALPY.LEAVING) TSH = 0.986 X 1.10 X 1,064 X ( 76.812 - 55.000 ) = TLH = 0.986 X 0.68 X 1,064 X ( 66.498 - 60.339 ) = SUM = GTH = 0.986 X 4.50 X TOTAL SYSTEM LOAD CHILLED -HOT WATER FLOW RATES: COOLING GPM = HEATING GPM = LATENT GRAINS SENSIBLE TEMP CFM 55.000 0 0.000 0 1,154 1.000 53 21,923 18.999 1,011 23,077 75.000 1,064 1,154 1.000 0 0.000 937 0.812 0 0.000 4,394 66.498 25,168 76.812 1,064 1,064 X ( 28.840 - 22.558 ) = 25,168 BTUH 4,394 BTUH 29,562 BTUH 29,654 BTUH 29,562 BTUH 29,654 / ( 10.0 X 500 ) = 5.9 GPM 11,383 / ( 20.0 X 500 ) = 1.1 GPM ENTERING COOLING COIL CONDITIONS: ENTERING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 76.81 WET BULB TEMPERATURE: 63.29 RELATIVE HUMIDITY(%): 47.71 ENTHALPY: 28.84 BTU /LBM LEAVING COOLING COIL CONDITIONS: LEAVING HEATING COIL CONDITIONS: DRY BULB TEMPERATURE: 55.00 WET BULB TEMPERATURE: 53.75 RELATIVE HUMIDITY( %): 92.49 ENTHALPY: 22.56 BTU /LBM DRY BULB TEMPERATURE: 50.04 DRY BULB TEMPERATURE: 95.00 ** QUICK COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** AMBIENT CONTROL FEDERAL WAY, WA 98003 Azteca Southcenter C.. 01/25/99 PAGE 9 * * * * * * * * * * ** TOTAL BUILDING OUTSIDE AIR AND LOAD PROFILE SUMMARY * * * * * * * * * ** THIS SUMMARY ACCOUNTS FOR ALL ACTIVE ZONES IN THE PROJECT OUTSIDE AIR QUANTITY (CFM) % OF 1064 CFM SENSIBLE BTU LATENT BTU SUMMER VENT AIR = 72 SUMMER INFL AIR = 0 TOTAL SUMMER = WINTER VENT AIR = WINTER INFL AIR = TOTAL WINTER = * * AUGUST * HOUR ZONE.SEN 1 AM 0 2 AM 0 3 AM 0 4 AM 0 5 AM 0 6 AM 0 7 AM 0 8 AM 15840 9 AM 17202 10 AM 18564 11 AM 19654 12 PM 20561 1 PM 21197 2 PM 21287 3 PM 21106 4 PM 20470 5 PM 19471 6 PM 18201 7 PM 16839 8 PM 15749 9 PM 15204 10 PM 14841 11 PM 14568 12 AM 14387 110 0 JUNE ZONE.SEN 0 0 0 0 0 0 0 16293 17656 19018 20107 21016 21651 21742 21560 20924 19925 18655 17292 16203 15659 15294 15023 14841 6.765% 937 643 0.000% 0 0 10.336% 0.000% MONTHLY AND HOURLY BUILDING SENSIBLE LOAD PROFILE JULY ZONE.SEN 0 0 0 0 0 0 0 16476 17838 19199 20288 21197 21833 21923 21742 21106 20107 18836 17475 16385 15840 15477 15204 15023 SEPTEMBER ZONE.SEN 0 0 0 0 0 0 0 14750 16112 17475 18564 19471 20107 20198 20017 19381 18382 17111 15749 14660 14114 13751 13479 13297 937 643 6,323 0 6,323 JANUARY ZONE.SEN 0 0 0 0 0 0 0 11300 12662 14024 15113 16022 16657 16748 16566 15930 14931 13661 12299 11209 10665 10302 10029 9847 * FEBRUARY * ZONE.SEN * 0 0 0 0 0 0 0 12208 13570 14931 16022 16929 17565 17656 17475 16839 15840 14568 13207 12117 11572 11209 10936 10755 ** QUICK COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWARE DEVELOPMENT INC. ** AMBIENT CONTROL FEDERAL WAY, WA 98003 Azteca Southcenter ' 01/25/99 < PAGE 10 * * * * * * * * * * * * * * * * * * * * * * ** TOTAL BUILDING LOAD SUMMARY * * * * * * * * * * * * * * * * * * * * * ** BUILDING PEAKS IN JULY AT 2 PM BLDG. LOAD AREA DESCRIPTIONS QUAN ROOF WALL GLASS SKIN LOADS LIGHTING EQUIPMENT PEOPLE PARTITION VENT 110 INFL 0 DRAW -THRU FAN BLOW -THRU FAN SUPPLY DUCT RETURN DUCT BUILDING TOTALS BUILDING SUMMARY LOAD DESCRIPTIONS VENTILATION INFILTRATION ZONE LOADS PLENUM LOADS FAN & DUCT LOADS BUILDING TOTALS 616 0 0 616 4,903 43.07 500 2,000 22 220 72 0 SEN. %TOT LOSS LOSS 4,903 43.07 0 0.00 0 0.00 0 0.00 O 0.00 0 0.00 157 1.38 6,323 55.55 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 6,323 55.55 O 0.00 5,060 44.45 O 0.00 0 0.00 TOTAL BUILDING SUPPLY AIR (BASED ON A 20 TD): TOTAL BUILDING VENT AIR (6.76% OF SUPPLY): TOTAL CONDITIONED AIR SPACE: SUPPLY AIR CFM /SQ.FT. OF CONDITIONED SPACE: SQ.FT OF CONDITIONED AIR SPACE PER TON: TONNAGE PER SQ.FT OF CONDITIONED AIR SPACE: TOTAL HEATING WITH OUTSIDE AIR: TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: LAT. GAIN 11,383 100.00 4,394 SEN. %TOT LAT. LOSS LOSS GAIN 643 0 3,751 11,383 100.00 4,394 + SEN. = TOTAL %TOT GAIN GAIN GAIN 0 6,537 0 0 O 0 + SEN. GAIN 937 0 21,923 O 0 0 2,308 1,064 CFM 72 CFM 616 SQ.FT 1.7277 CFM /SQ.FT 250.0507 SQ.FT /TON 0.0040 TONS /SQ.FT 11.38 MBH 4.46 TONS .. 6,537 22.11 0 0.00 0 0.00 O 6,537 6,537 22.11 0 1,876 1,876 6.35 O 7,502 7,502 25.38 3,751 5,929 9,680 32.74 0 79 79 0.27 643 937 1,580 5.34 0 0 0 0.00 O 0 0 0.00 0 0 0 0.00 0 1,154 1,154 3.90 O 1,154 1,154 3.90 25,168 29,562 100.00 = TOTAL %TOT GAIN GAIN 1,580 5.34 0 0.00 25,674 86.85 0 0.00 2,308 7.81 25,168 29,562 100.00 ACTIVITY NUMBER: M99 -0026 DATE: 1 -26 -99 PROJECT NAME: AZTECA MEXICAN RESTAURANT XX Original Plan Submittal Response to Correction Letter# Response to Incomplete Letter Revision # After. Permit Is Issued DEPARTMENTS: Buil ding Division � t _LT'S Public Works \PR- ROUTE.DOC G/98 %y*F Coc*d. Cody PLAN REVIEW /ROUTING SLIP TUES /THURS ROUTING: APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Condition Fi e Prevention fZ ( Struc ral ❑ DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ( Incomplete ❑ Comments: Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) Planning Division ❑ Permit Coordinator DUE DATE: 1-28-99 Not Applicable E Please Route ❑ No further Review Required DUE DATE: 2 -25-99 REVIEWERS INITIALS: DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS. DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY REGIST, # EXP. DATE CCAAAB 10/16/1999 EFFECTIVE DATE 10/16/1990 AMBIENT CONTROL CO INC 1020 . S 344TH ST STE 20 FEDERAL ' WAY .WA . 98 6726' Signature Issued by DEISARTMENT OF LABOR AND INDUSTRIES RECEIVED CITY OF TUKWILA JAN 2.7 1999 PERMIT. CENTER