Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M99-0029 - BON MARCHE - HOME CENTER
M99 -0029 17750 Southcenter Pkwy. Bon Marche Home Center City of Tukwila c Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M99 -0029 Type: B -MECH Category: NRES Address: 17750 SOUTHCENTER PY ' Location: Parcel #: 262304 -9110 Contractor License No: MACDOM *248J9 UMC Edition: 1997 Signature: MECHANICAL PERMIT Valuation: Total Permit Fee: (206) 431 -3670 Status: ISSUED Issued: 02/09/1999 Expires: 08/08/1999 TENANT BON MARCHE HOME CENTER 17750 SOUTHCENTER PY, TUKWILA WA 98188 OWNER MBK NORTHWEST Phone: 206 -575 -8090 C/O TRAMMELL CROW COMPANY, 17560 SOUTHCENTER PY, TUKWILA WA 9818 CONTRACTOR MACDONALD MILLER CO Phone: 206 763 -9400 7717 DETROIT SW, SEATTLE, WA 98106 CONTACT JESSE MONTEZ Phone: 206 -768 -4288 7717 DETROIT AV SW., SEATTLE WA 98106 *** k*************** k* k******• k*****• k**• k***** k**• k *** *k** ***•k * *k *•k ** * *•k *** *kk* Permit Description: REPLACE 5 EXISTING ROOF TOP A/C UNITS WITH LIKE, SIZE AND CAPACITY - REPLACE 2 UNIT HEATERS WITH NEW ROOF TOP A/C UNIT W/DUCTWORK, T -STATS AND GRD'S. 56,000.00 212.00 ********©******. * ** *k ****** * * * ** * * * * *•k *** *•k* k** * * * *•k* * *•k * * * * * * * * *'k*** * *•k ** ?66L Permit Center.Aut orized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performan'= of work. I am authorized to sign for and obtain this build per *1 # Print Name: I' I 7 Date: 02 P/9f T i t l e : 664 IGD7� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Permit No: M99-0029 Status: ISSUED Applied: 01/28/1999 Issued: 02/09/1999 k***P*k*A**k**Akkkh****kkkkkkA***kh***k*h***khleA***Ak*kk***k.k.kk*Akk****kAk* Permit Conditions: 1. - No changes will be made to the plans unless approved by the Architect or Engineer and the Tukwi la Building Division. All permits, inspection-i.*064*ved plans shall be available at the 1,00 any con- struction. These)dOC6mentsa to .be maintaland avail- able until finnspecOohapproOal is granted 3. All contrtict ton tobeddile AnpcOnf'OnmanWWith approved plans and Of the Uniform 3ui ld.thg Code (1997 Edition),(a'S'amended,*. UniforMAleCKantcal,Code,(097WOon), and Was.hfngitP0 State Energy Code (1997 Edition) 4. Validity,of4'ermit., The isSuanCe.of a permit or 4P1;Tov,of plan s specifications, and,'Computat:ions shall'Aotbe con- strued,ito°be a permit for',- or an approval of any v1,61atiOn,4, of any:'of prOvisicinS of 'Oe,building code or presuming to giv'e violate_orcancei provisionS,of, code 'shall be valid: , \ 5. MANOOCTURERS INSfALLATION:INSTRUCTIpNS REOUIRED ON,S145 Address: 17750 SOUTHCENTER PY Suite: Tenant: BON MARCHE HOME CENTER Type: B-MECH Parcel #: 262304-9110 FOR4 BOLDING-I.NSPECTORSREVIEV . ; t r ,. , • • . •, - , t ■ ,,,- I ' 43- CITY OF TUKWILA • .•' / :t); 1., • Proj tAR- Y.- LAY mn r - (t.pt .. eJer —e>& ^ Fe!- Value ofr tt � ruction: Site Address: M sa o ga- f,82.4.(e- ?A City State /Zip: .e) wk.4.21 Lis. w A ' . (& • Tax Parcel Number: 6 .... - (/0 Property Owner »i �& . (i..) . I Phone: Phone: .5b 3 - 49 / -947) o Street Address: 74 i Sib LO ' n City State /Zip: _A — ('12.. ' a 6 Z Fax #: Contact Person: / A M' S'SE MOP( AE- _- Phone: Z46 - 76d'`« g' Street Address: 1 717 PP7Z6(T City State /Zip: / Say SEA -444. 4IA le /66 Fax #: 4d6 76 e lee? Contractor: NC Ao, _ t tie a Pho Z e) 6 — 76 ( gT Street Address: City State /Zip: 9 PF Te-a tZ 4-014. <a) 5e 4- G(.. A fie/04 Fax #: Zd 6 - 74 S' s 9 Architect: Phone: Street Address: " A1l14 City State /Zip: Fax #: Engineer: / .7 - 10.0 e- Iuaat /e 2 -- Phone: •zO6 — 76 a' - 0 e Street Address: . State /Zip: 7 7 t 7 74 SGi .S.e.e -h'2e G ? 't a 6 Fax #: 2 � 6 ... 7 � V '- 9 e MISCELLANEOUS. PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) 1 I g Description of work to be done: gi a p e4 ce- F A<tr/S ?/A P007c ./ AC G44. /f'5 DL fit .4, et /10 A , . e ,„.. .--• _ - , 14 .4eas 41. A)' ea. - - - 1/ o , , e 1 0.0 L Will there be storage of flammable /combustible hazardous material in the building? ❑ yes �o 7. a mt's , 6g Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ❑ Bulkhead /Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence ®'f'vt ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: I Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application APPLICANT. REQUEST. FOR MISCELLANEOUS PUBLIC WORKS PERMITS: in Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: Date application accepted: CITY OF r 'IKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be t. :reviewed and is subject'tp possible revision by the Permit Center to comply with current fee echedulps. . Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by liatation: beillaing official may extend the time for action by the applicant for a peikid,not bxceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. /-20 -11 MISCPMT.DOC 7/11/96 Date application expires: Phone: City /State /Zip: Apollo lion taken by: (Initials) D's BUILDING OWNER OR AUTHORIZED AGENT: 3UB ?JIUT APPLICATION AND REQUIRED CHECKLISTS FOP, Above, Ground Tanks/Water Tanks - Supported directly upon grade excediiing 5;600•gattoriS and a ratio of height to diameter or width which exceeds 2:1 .. PERMIT REVIEW Submit checklist NO: , M -9 • b: , ;•' I • ` ' ' Date: /..... z4, _.9 f Signature: ....42,2_41 Print name: 1 J pOS E HO") lea 2-- PhonPie _7�g so i Fax #� Address: 7 7(7 D e / • 4 Aide 5Uv City /State /Zip 5 4eze 6)4 Cir/Q 6 0 3UB ?JIUT APPLICATION AND REQUIRED CHECKLISTS FOP, Above, Ground Tanks/Water Tanks - Supported directly upon grade excediiing 5;600•gattoriS and a ratio of height to diameter or width which exceeds 2:1 .. PERMIT REVIEW Submit checklist NO: , M -9 • b: , ;•' I • ` ' ' 0 Antennas /Satellite Dishes ' ' . "' ' ' " " StiISrtfift checklist''• No': 'M 2 -'1 ® Awnings /Canopies : No signage ' : ''.1 - •- ' Cbrnrnercial Yenant'.Improvement Permit • .. Bulkhead /Dock' ' ` • k ': ..:'`• : ti { •" • t;ubmil checklis ' i t No: M -10 0 Commercllal•Rer • • • • , • Submit checlilist.r. Nb :'••hll -6 0 Demolition • • • • . At {. „ :,•:„'. • .{ , • t €ubr lit cheokiistr: No; i lua, M -3a Fences - Over 6 feet in Height Submit checklist No: • • M -9 0 Land Altering/Grading/Preloads Submit checklist No; ,M -2 Losding Rocks • Commercial.Tenant Improvement Permit. • Submit cher�klfSt' No :•H -17 .Mechanical • (Reside,r4ial $( Commercial) •,� • ' '� •' •. `• Submit checklist No. M -8 Residential only ` .H- H -16' • . . 0 Miscellaneous Public Works Permits Submit checklist No: H -9 ' h ManufactuYetd Hdusin -(AEb IN SIGNI VONLY)•'� • • : ' • 'I, • •• : . :� •. • . I. ',t. • . • ... • ! •.r • * , . •' Submit checklist, No: M -5 ' . - • • « k 1UFoVf .1" 4 •n. g Oversized Load /Hauling Submit checklist No 'M -5 Parking Lots Submit checklist No: M -4 O Residential Reroof - Exempt with following exceptiorii. If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 Retaining Walls - Over 4 feet in height Submit checklist No: M -1 0 Temporary Facilities Submit checklist . No: M -7 0 Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 ri Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PEI') IT APPLICATIONS MUST BE SUBMI ED WITH THE FOLLOWING: ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) MISCPMT.DOC 7/11/96 •., . , t : .� .' .`�. , � , 1, _` . � • it I • � . • • Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. ✓ //Floor Working Drawings plan System layout Elevations (for roof mounted equipment) and proposed screening / 'Heat Loss Calculations f Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504(e)) H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut -off and will be routed to the Fire Prevention division for additional comments, code section Uniform Mechanical code 1009. Provide 2 sets of manufacturer's installation instructions ✓ l- Document Requirements Documentation or specifications must be provided to show that replacement equipment complies with -the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required to replace existing roof equipment weighing 400 pounds and greater (Uniform Mechanical Code Section 2336(a)) Water heaters and vents are included in the UMC - please include any water heaters or vents being installed or replaced. ,. .. Structural calculations stamped by a Washington State licensed Structural Engineer shall be required if structural work is to be done • Number of units Provide 2 sets of manufacturer's installation instructions ✓ Working Drawings On 8 1/2 x 11 sheet of paper include the following: Narrative of work to be done (i.e., changeout, replace existing equipment, modifications, etc.) • Type of unit being installed • Rating /Size • Number of units Provide 2 sets of manufacturer's installation instructions Note: Water heaters and vents are included in the ,Uniform Mechanical Code - please include any water heaters or vents being installed or replaced 2/97 CITY OF i I KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Md M -8 Submittal Checklist Miscellaneous Permits MECHANICAL PERMIT COMMERCIAL: Four complete sets of drawings and attachments required with application submittal RESIDENTIAL: Four complete sets of drawings and attachments required with application submittal # kh*: 1 **** Ak* A: k/ r* h**h A*: 1. a4; 1: 1k*: 1•****** A• k*: 1*.* drA• *;kA *rl•M *:1 *•.kdrAAA•k *.t *:1 3 TY or TUI <WILA « WA I RAN5N1:'C kA *kA ** ** ** *A * **** * ** **Ankh *•k * *A ** ** A ***A *:1 * *:1 *AA *A *:1 *•A4 * *;1• *.kA Jr** TRANSMIT Number; R9S00010 Amount: 212.00 02/09 12:04 Payment Method: CHECK Notation: MACDONALD MILLER initt 81.11 Per ^mit No: 1499 -0029 Type; fl -141 CH MECHANICAL PERMIT - Parcel No 262'304-9110 Site Address: 177;x0 SOUTHCI=NTER PY Total reesg 212.00 212.00 Total ALL Ruts: 21:.170 8 ct l ante: .00 r;4 * *AA* * * *AA *A**A *i0 sn *•k *A * * * * * ** * * * * * * *A* dr. * * * * * * * *** * ** *** *4 *A* T h i s Payment Account Code •000 /345.830 S0/ ?22.100 Description PLAN, CHECK - NONRCB MECHANICAL -- Npi1REB Amount " '4 1 , 2. 40 4 .A =R HANDLING -( LJN ='I' 1 Job Name: PARKWAY SUPERC 4TER Job No.: 1 01 -26 -1999 s Total Area: 8280.00 Sq. Ft. Cooling Calculation for JULY at 1600 Outside Temp: 81 Inside Temp.: 74 G l a s s C a l cu l a t i c z So1. Sol. Shade Trans Total Sch Dir Area Factor SC Btuh . U TD Btuh Btuh 2 E 684.00 55.64 0.66 16583 0.67 0.54 14 5171 21754 Wall Solar: Arid Trarismissiori Gams Net Wall Glass Total Sch. Dir. Area U -val Btuh total w /Glass 1 E 52.50 0.05 71 0 71 1 W 1050.00 0.05 3213 0 3213 2 E 313.50 0.05 423 21754 22177 Roof Arid S]1 ig1it Gairis Roof Skylight Total Roof Area U -val TD Btuh btuh btuh 8280.00 0.05 58 24972 0 24972 Electrical Gams Watts/ Lights Watts/ Equip. Misc Total Sq.Ft. Btuh Sq.Ft. Btuh Btuh Btuh Lights: 1.20 33912 Equip.: 0.00 0 3000 36912 Occv.paric r Gairis No. Of Btuh Total Btuh Total Total People Sens. Sens. Lat. Lat. Sens. & Lat. 41 245 10045 205 8405 18450 Outdoor• Air Gairis Sens. Lat. Total CFM TD Btuh Gr /Lb Btuh Btuh Vent: 820 7 x 1.085 6228 12.00 x 0.68 6691 12919 Infil: 1208 7 x 1.085 9171 12.00 x 0.68 9853 19024 Total: 2028 7 x 1.085 15399 12.00 x 0.68 16544 31943 PLENUM LIGHT HEAT 0.00 PLENUM ROOF HEAT 0.00 Building Total: 106561.3 Fan Motor Heat: 6300 ( 2.00 HP) Unit Sens: 119089 Lat Total: 24949 Grand Total: 144039 Sens Heat Ratio: 0.78 Total Tons: �„ Sq. Ft. /Ton: 689.82 AC7G' `z RECEIVED CITY OF TUKWILA JAN 2 8 1999 PERMIT CENTER -A =,R HANDLING UNIT 2 Job Name: PARKWAY SUPERChNTER Job No.: 1 Total Area: 11070.00 Sq. Ft. Cooling Calculation for JULY at 1700 Outside Temp: 80 Gl ass Cal cul at: iorls Sol.HG Sol. Shade Sch Dir Area Factor SC Btuh % U TD 4 N 600.00 27.75 0.66 10989 0.67 0.54 12 4 S 504.00 59.86 0.66 19912 0.00 0.54 12 4 W 912.00 119.84 0.66 72134 0.00 0.54 12 Wa11 Solar And 'Trarzsmission. Gains Net Wall Glass Total Area U -val Btuh total w /Glass 100.00 0.05 120 84.00 0.05 143 152.00 0.05 547 560.00 0.05 672 700.00 0.05 1190 658.00 0.05 2369 Sch. Dir. 4 N 4 S 4 W 5 N 5 S 5 W Roof And Skylight: Gairzs Roof Skylight Roof Area U -val TD Btuh btuh 0.07 0.05 61 0 0 E1ec rica1 Watts/ Sq.Ft. Lights: 1.20 PLENUM LIGHT HEAT Building Total: 189660.6 Unit Sens: 212572 Sens Heat Ratio: 0.84 Gain s Lights Btuh 45338 Occupancy Gairis No. Of Btuh Total Btuh People Sens. Sens. Lat. 55 245 13475 205 Outdoor Air Gains Sens. CFM TD Btuh Vent: 1100 6 x 1.085 7161 Infil: 1292 6 x 1.085 8408 Total: 2392 6 x 1.085 15569 Watts/ Equip. Sq.Ft. Btuh Equip.: 0.00 0 Total Lat. 11275 Gr /Lb 12.00 x 0.68 12.00 x 0.68 12.00 x 0.68 14877 14997 23178 23321 78044 78591 0 672 0 1190 0 2369 Total Sens. & Lat. 24750 Lat. Btuh 8976 10539 19515 01 -26 -1999 Inside Temp.: 74 Trans Btuh 3888 3266 5910 Total btuh 0 Misc Btuh 1300 0.00 PLENUM ROOF HEAT 0.00 Fan Motor Heat: 15750 ( 5.00 HP) Lat Total: 30790 Grand Total: 243361 Total Tons:' 'O 28' Sq. Ft. /Ton: 545.86 Total Btuh 14877 23178 78044 Total Btuh 46638 Total Btuh 16137 18946 35083 '�b ♦ �,trr:��" fit? i% s. ✓:1'�.1 V66DDqq CIT OF IUKAIILA ' RMIT CENTER MCICIV0019 Dote: i 1/26/99 1 Paget; Sent : 2 b No.: : 97552.09 : Lencludingoover shout) i ...... Aftontion: • Jena MOntez : COMIIMPjf NaRie: I MacDonald Miller Co. From: .: Jarod Winnen : Rut No.: 1_1206) 768-4289 . , • : Mectiani ..NE I L I T H eg • ton. snon , *a.... 1,4.,.... ...vv.*. •P Message: ; Jesse: Attached is the sheet that didn't go through. Thanks, Jarod ••••••■••••••••••••••• Copies Too i • . • • •.................•.....•.............4..............,...... 000000 WZIPON.0.1■014...••••14.1.•••••••••••,..••••••••••••■•• After Faxing, pleasso: : 0 Filo 0 Masan to Sender 0 Mali El Dismal * PLEASE CONTACT THE SENDER F YOU DO NOT RECEIVE ALL PAGES JAN-28-99 08:61 FROM-KPFF Cluet.h.ny lh•wnst 603-22T-7980 FAX COVER SHEET 111 SW 5117 Avow" Sul* 2500, Portland, OR 07200 (50.1) 227-32si Fax No. (503) 2274180 T-092 P.01/081 F-304 RECEIVED , CITY OF TUKWILA JAN 2 8 1999 01/25/99 15:24 COnsulfinp Espb,ss,s FAX COVER SHEET Date: 1/25/99 Paws Sent: 11 1 Job No.: 1 97552.09 A ttention: Jesse Montez { Company Name: MacDonald Miller Co. :_. Inc From: Jarod Winnen .1 Fair No.: (2061768- 4289 ��' . __ _.._ ,.RoaaidIng: The Bon Mechanical Message: Jesse: Attached are stamped calculations verifying mechanical unit placement at the lower roof (AC -1 through AC-5). Calculations for unit AC- 6 will follow as soon as a concensus is reached on how to bring. the roof structure up to the•required capacity. A hand copy will follow. Thanks, Jarod _C 8 To: Todd RaMain �__...._... .� S� eria Const __.__...__ i_,Be After Foxing, please: To File ❑ Retum to Sender ❑ Mall ❑ Discard * PLEASE CONTACT THE SENDER IF YOU DO NOT RECEIVE ALL PAGES * 111 Sw 5th Awns". Sully 2600,. Ponla d OR 97204 (5021 2274251 Fait. No.. (600)_ 227 7910 Ii 001 /010 01/25/99 15:24 WM • Consulting Engineers January 25, 1999 MacDonald Miller Company, Inc. Mr. Jesse Montez 7717 Detroit Ave., S.W. Seattle, Washington 98106-1903 RE: Parkway Supercenter The Bon Mechanical Tukwila, Washington Dear Jesse: Attached please find calculation sheets, 1 through 5, dated January 25, 1999, which verify the structural adequacy of the roof mechanical supports (Units AC -1 through AC-5) for the Parkway Supercenter, as shown on sheets SI through S4, dated January 25, 1999. Design is based on the requirements of the 1997 Uniform Building Code, as amended by the State of Washington. If you have any questions or require further information, please call. Sincerely, Jarod M. Winnen Attachments [JMW kwAB7552.0910125cal.doc) r EXPIRES: 9/12/00 1 111 S.W. F11117 Avenue, Suite 2500 Portland, OR 97204.3028 (503) 227 -3251 Fax (503) 227 -7980 Seattle Portland San Francisco Los Angeles Phoenix San Olepo IJ002/010 01/26/99 16:25 Portland, Oregon Iff Consulting fnglneers -I P • • P �. c ..li r . rc. ...,NlvrrVAt'r • :S3'l +J.;' =7 w.. o9 I oet f ,���/rr�✓�� ��^�"Z4.4 Location T _. Fj p„„ % j Vent / a N -b /tl J( uti ;_ r fir,•• c,, S'.s • 1 9 • r C.?- ! S losF“ zmi, .. ......... • `8 ..... t= - ?Js .9 I b l 3 7- G':04 - pig (1.rr) (Q, 7x-0). '; /yg; --pes '• .i 8 ,C t*c • '� /be �pw' 2-6: 4. ; ti -/ 4.1—) • r .. ' ., ..III .'� ...I. ....... ►. ... • t I; . BY gY�irAQ date r /2,.. 7 Uevbed Dais • ' ' 0.ve /6 Q003/010 Sheet No. Job No r 01/25/99 15:25 12 KPFF Consulting Engineers Portland, OR L 504002 Single Span Beam Analysis Page 1 Description GL 51/8 x 21 w/ Unit AC-5 (W=895 lb) DL =15 SL =25 L General Information Center Span Left Cantilever Right Cantilever Magnitude Location 28.87 ft 5.50 ft On Center Span... # 1 0.820 ktft 4.048 k -5.600 ft 1 Moment of Inertia Elastic Modulus ft Beam End Fixity [Uniform Loads Summary Momenta... Max + at Center 81.97 k -ft at 14.36 ft Max - © Center -34.87 k -ft at 0.00 ft Left Cant -34.87 k -ft © Right Cant 0.00 k -ft Maximum 61.97 k ft f.94- 0000) Scope : 3,955.000 in4 1,800 ksl Pin -Pin On Left Cantilever... *1 0.820 k/ft 0.895 k 13.330 ft Tine : Parkway Plaza Job # 97552 Dsgnr: JMW Dom: 2:28PM, 8 JAN 99 Description : The Hon Home Center Mach Unit Framing [Point Loads Shears... © Left Right Maximum Deflections... Center © Left Cant. 4 Right Cant k ft •3 .4.4, y y is o (b /5 ( . ° 12.88 k 10.08 k 12.68 k t K ell On Right Cantilever... # 1 k/ft k if Reactions... Left Q Right -1.025 in at 13.98 ft 0.431 In at -5.50ft 0.000 In at 0.00 ft k ft 21.24 k 10.08 k /9e. a- r' ✓� 1lL IJ 004/010 fi "NI Consulting Engineers Portland, Orogen Pto cl !a g v 7',x4 r:4 Sheet No. Job No. 770'2_, 0 Location Dole ' / tovrood /,r9 Mont Date • • • • /1:. ; ;... 1 • NZ ; i s mot. r4.- ... N:W- r � • �r � ..... I tf • . • a 's y L ! ' (5 ; / 7-� G. S^ ,. • ■ ;.. } • :: . ! 1 ■ t _.,... . E • 15:26 (1/94) lJ0O5 /O1O JAN -26 -99 08:51 FROM -KPFF i EMI Convulsing Engineers ,--» �Cl,prr PwttiiC Otenon ec PI WART flit UV.* M .' 75'9 »(o Fr .ts. 6 ° 2. Y•a C f, , * -)C C V) Cr I. ('''. '3-112-e 4.i. "..PiZi .°1 4'96 /I.- q ) . .∎ l a. I L - - - Pi. 2- / 9 PE) ■arm 7-"- � ✓ 503 -22T -7980 tuG l b y .1 1t w./ ��M�t t- 1 4+5 - 11 7..s�•1 b 9 cli • T� —�= - I p :1G - (?S psi T -092 P.02/02 F -394 Rrn:ou ru0 N4 Descr!atop; 6 x 8 Column 9 Bldg "C" Parkway (The Bon) P (Ifs) Lex _ n (in) _. Ley _— dx (in) _ d (Le /d)max 29.60 n A 56.25 (In2) E psi) Fc (psi) �_ CD Cm Ct CF CI CT E' Kee 16 00000 (psi) c Fee 547.8451 (psi) Fe* 1150 (psi) Fce /Fc" 0.478387 (1 +Fce/Fc*)/2c 0.922742 Kf 1 Cp 0.416808 01/25/99 15:26 Sheetl '8b'= 3 n✓ IA-5 //I' Ij 006/010 .5 01/25/99 r r u' . r gL 1 1 r � I_ Stteo-r S1 Is 11 r - - L_ J tj 0 07 / 01 0 p 4 0 1 s 01/25/99 15:27 (1/841 t1 008 /010 NVIA MacDonald - Miller RECEIVED MAR 1 4 2000 City of Ylukwila, Dept of Comm. Dev. D OPMEN 6300 Southcenter Blvd, Suite 100 Tukwila WA. 98188 a GroupM4C "company Re: Mechanical permit M99 -0029 Attention: Bill Rambo Dear Bill, The job for which this permit was issued was cancelled before work could commence. Please cancel this permit. Construction & Engineering/ 7717 Detroit Avenue SW Seattle, WA 98106 -1903 206 763-9400, Fax 767 -6773 2 eT 3 March 10, 2000 Jesse Montez 7717 Detroit SW Seattle Wa 98106 Dear Mr Montez: Sincerely Bill Rambo Permit Technician Cizy of Tukwila RE: Permit Status M99 -0029 17750 Southcenter Parkway RiaJ, Xc: Permit File No. M99 -0029 Duane Griffin, Building Official In reviewing our current permit files, it appears that your permit to replace roof -top A/C units .. issued on February 9, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Fax: 206-431-3665 ACTIVITY NUMBER: M99 -0029 PROJECT NAME: BON MARCHE HOME CENTER Original Plan Submittal Response to Incomplete. Letter Response to Correction Letter # Revision # After Permit Is Issued DATE: 1 - 28 - 99 DEPARTMENTS: B i ing Division Pu lic Works� Cirirni4V Coord. Cop PLAN REVIEW /ROUTING SL1P CJ 10 Fire Prevention 2.3-89 Structural DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 2 - - 99 Complete 0 Incomplete El Comments: TUES /THURS ROUTING: APPROVALS OR CORRECTIONS: (ten days) Approved \PR.ROUTE.DOC 6/98 Please Route No Review Required 0 Approved 0 Approved with Conditions 0 Routed by Staff 0 (if routed by staff, make copy to master file and enter into Sierra) Planning Division Permit Coordinator IIII Not Applicable El REVIEWERS INITIALS. DATE: DUE DATE: 3 -2 -99 Not Approved (attach comments) 0 REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved with Conditions 0 Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: C Fire Department Review Control #M99 -0029 (510) City of Tukwila Fire Department February 3, 1999 Re: Bon Marche Home Center - 17750 Southcenter Parkway Dear Sir: The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Thomas P. Keefe, Fire Chief H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 2. When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 57.5-4439 Page number 2 Yours truly, City of Tukwila Fire Department The Tukwila Fire Prevention Bureau cc: TFD file ncd 3. Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1742) 4. Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) • Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 F62;1.0:1240) t8/971 Detach And Display Certificate — DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP . DATE ccol troopomtammotoott EFFECTIVE DATE 04/29/1976 0444P9N40,4441 7717 DETROIT AVE SW SEATTLE WA 98106 Dr.tach .\114.1 Dipkty CertifiLati. FILE COPY MacDonald Miller Company, Inc. 7717 Detroit Ave. S.W. Seattle. Wa 98108 -1903 Phone: (208) 763 -9400 Fac (206) 767 -6773 Wash Lic Na 223- 01- MA -CD -OM -248,19 p � P el, C7STSS, tr0 staNAL EP , IEXPIRES: 6 -18 -195 d : -- ,.I AWN ROMECNT7 1593317 20n Hi 79 F'EVISIDNS: DATE bON HOME CENTER 17750 SDUTHCENTEK PKWY TUKIAIILLA. WA. 98158 lilinkl / ,uns rifAit-O RmDF PLAN - I-IVAC ExwxE T. MONTEL vs .a rs1o: 1 -19- eAcKA o, , WE PLOW. 12.30. 0 - r. DI un 55 . DO1 :ssuE urz. 1. x, xa . 0 -0348 -(513 NOT ISSUED FOR CONSTRUCTIQ, ,xrlxUUOEa. JAP{ 2 1 I -I-i 11 - 1 PERMIT CENTER FILE COPY 1 c ^ , " : : : - ' " I 1" _; T:o PAA h__k .- -- '. ... 1,7 7a end omissions d : -- ,.I F _ :. -_, not aWwdas he violation of c 7 , 7,.cd code or atdrlaom Iboelpt of centr .Ie. Q, o 1 ( (4' /��n Permit No ITI"I ` 1 C/v d'9 F �ArPraA HEI6HT ELEVATIONS NOT Tb SCALE 1 '4A5 PACKAGED GAS /ELEC AIR CONDITIONING' UNIT SCHEDULE UNIT N0. AG1 AC-2 AO3 A04 AC-5 AREA SERVED BON HOME CNTR BON HOME CNTR BON HOME CNTR BON HOME CNTR BON HOME CNTR BON HOME CNTR MAKE AND MODEL NO CARRIER 48H/D005 TRANS YC0001C4LOBC TRANS YCD09004LOBC CARRIER 48 .5 TRANS YCD060C4LOBC TRANS YCD150 CAP.MBH SENS 35.7 423 80.3 357 53.2 135 NOM TONS 12.5 GAS HEAT(MBH) INPUT 72 90 120 72 90 150 OUTPUT 59 73 97 59 73 122 160D 1.0 3000 1. 1900 5000 ESP I FAN 0.25 0.25 0.25 0.25 025 025 HP 1.2 0.5 1.2 0.6 30 OA -:EIIL CFM :SEER 11.05/13.00 410.0 9.0/- 11.05/13.00 -/10.0 -/8.3 ELECTRICAL VOLT/PH' 460!3 460/3 460Q 46073 460/3 MCA 14.6 13 22.1 14.6 16.9 LBS 574 fi8D 895 574 700 1505 NOTES 123,4,5x" 1,2,3,4,5 ,7 1,2,3,4,5,6,7 1,2,3,4,5, l 1,2,3,4,5, 7 NOTES: 1. AC UNITS LOCATED IN BUILDING STORAGE. 2. M -M TO PROVIDE CURB. 3. WITH ECONOMIZER. 4, E.C. TO PROVIDE DISCONNECT. 5, G.C. TO PATCH ROOF AS REQUIRED. S. SMOKE DETECTOR IN SUPPLY DUCT. MM TO PROVIDE AND INSTALL, E.C. TO CONNECT. 7. , -ELUV ptc y rr, -, .•a![c i - Srar L G2' 6A5 I.(hCEST ,IF,, fi r /' PARAP6T x516,47 / IAe-ts I T 13R Rn ➢F ---A- TY 5 UNITS 20' LIPPE, Tt0➢F A E2 RDOF `MUNIb NT ROOF PLAN Scale: Ys = mqq -oo.q CANCELLED M -I SEPARATE CER:'.:: - REQUIRED E MECHANICAL p 0LECTRICAL 0 I",UMBING GAS, PIPING CI Y ON TUI:'7:L A. BU DIVI310,1 q CIiN OF' iU(WILA 1 ,APPROVED 1 FEB (; 4 199' .Jti Wig -00291 I II MacDonald Miller Company, Inc. 7717 Detroit Ave. S.W. Seattle. Wa 98106 -1903 Rhone: (206) 783 -9400 Far. (206) 767 -6773 Wash Lic No 223- 01- MA- CD- OM -24BJ9 a, m�`o7' •A 8j G O 1zo6e b� oF ..s`SIONAL e�G E %PIRES: 6 -16 -1999 J A • ON HOME CNTK 1583577 JOM 14947 REVISIONS: DATE bON NOME CENTER 17750 SOUTHCENTER PKWY IUKWI LLA, NA 98IS6 FLOOR PLAN -14VAC °N J MON1El_ I- 14-99 °'°" .12 3orI8 71 MI lam, S. Doi& �E wow. D- 0348-158 3377 NOT ISSUED FOR CONSTRUCT1QL M -2 PERMIT CENTER P ,r P -0II2 -1' / i,E4/12.5 , 5M , if3/ GEM 3o /14s1 -St .,B` PLENUM SEECESAILI 7.`:O CFM DIFFUSER/GRILLE SCHEDULE SYMBOL szE MANUFACTURERS MODEL NUMBER TITUS BOORS M-M EGG CRATE SIZE AS NOTED 2424 TYPE DUCT MOUNTED REGISTERS RETURWFXH' NOTES WITH OBD, SEE DETAIL 1 ND `. - _ALE 31./18 td131 Da"REEAI A BON HOMECEAITEy 383317 SO NOTES, 17 M., TD PArLN L Q.EPAl2 OLDS 4 WAY PLENUM/ DIFFUSER DET L. 36/10 TYPL4] act /4O PLENUM SEE DETAIL 1 'I<CFJ'KJ. 7o E FLOOR PLAN CANCELLED M qqooaq n il 4 4/12 st-Sm A 16� NP(4) 24/34 RFJ.IDM SEE PETE, I 2A/24 P1.EIUJM SEE.DETA b NDTE I. � _-p 4-. BON' HOME C E N T E C . . 03377 JVt j- 17-44 FIELD UMATF_ Ems," TESTS, SAND & .v.-Ton AT S4.6 (nc4no 2,4/24 PIFJJLIM SEEDEr.4L 1 475C TYPC4] b 91 CllY 03 Tuawiu APPROVED II FEB B q 1990 11 �r�nrD II I I