Loading...
HomeMy WebLinkAboutPermit M99-0077 - PACIFIC GOLF.r. M99 -0077 • 1032 Industry Dr. Pacific Golf City of Tukwila L. (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M99 -0077 Type: B -MECH Category: NRES Address: 1032 INDUSTRY DR Location: Parcel #: 252304 -907] Contractor License No: HEATT* *20600 TENANT PACIFIC GULF 1032 INDUSTRY DR, TUKWILA, WA 98188 OWNER PACIFIC GULF PROPERTIES 631 STRANGER BLVD, TUKWILA WA 98188 CONTACT TOM MCLOSKEY BOX 1268, CARNATION, WA 98014 CONTRACTOR HEATTRANSFER COMPANY PO BOX 1268, CARNATION WA 98014 *** k*********************.********************** * * **•*k** * * ** * * * ** *** * * * *k *•k* Permit Description: Status: ISSUED Issued; 04/26/1999 Expires: 10/23/1999 Phone: Phone: (206)575 -0765 Phone: 425 - 885 -3247 Phone: 425 885 -3247 REPLACE EXISTING HEAT SYSTEM WITH NEW. ELECTRIC TO GAS CHANGEOUT. UMC Edition: 1997 Valuation: Total Permit Fee: 5,000.00 46.50 • k******.• k********.***********' k*• k****•* * * *. * **•k * * **•k * * * **** ** * *•k * ** k* * * * * * * *•k k* -4 2-(P - Cj Permit CenteU Authorized Signature Date I hereby certify that 1 have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will he complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 ani authorized to sign for and obtain this building permit. Date: Print N a m e:- 7��� _/"/P ° Title: 46 _ � This permit shall become null and void if the •work is not commenced within 180 days from the date of issuance, or •,if.the work is suspended or abandoned for a period of 180•days•from the last inspection. CITY OF TUKWILA Address: 1032 INDUSTRY DR Permit No: M99-0077 Su i te : Tenant: PACIFIC GULF , , Status: ISSUED . Type: 8-MECH App 1 ied: 04/12/1999 Parcel #: 252304-9071 Issued: 04/26/1999 **********-k************.k*****************************A*****.h*************** Permit Condi t ions: 1. Any expoSed insulations backing material 'hi1 have a 'Flame .Spread Rat ing of 25 or 1 ess,,rand,Tplatex i a 1 sha 11 bear i dent i - J i c t i o n s h o w n g the J...ire719::IvitpEmi'n2&!,:p4r19 thereof 2:. Plumbing permi ts ;400qilj4-66Ealned 1fil-01-14iupreSeatt 1 e-Ki ng .County Depar tment4gf:-:Pub, 1 ii,p 1,!110,a I tr PlumbT6-670:11t1 be inspected by tfiW"'ag#rfc,A., .•;i nt 1 u d 10 tt a. 1 1 4..s,, p fonk, (296-471'2) .,V.-,-' ,,,,,, ",:.;!;) -Y q,, 3. El ectr i calp,ei...m i t:7;:',0a,1 V be obta)ned" through the Washington State D iy.,;,t,,FA on of ''I,bor and 'jft.i'a usir fe S', and a11,61,ec 64) , • work w tpb e.,:.',.)ns:', 0 et': t 0; by or)'0A ag en cy (24t3-6630.. 4. No changes wi 11,,,be made to the ;Plans un 1e approt*ed!:.p.).-i,,,,Ow. Engine and the Tbkwi la iil,U tl ding ';Division. 5. All 0 Orin 1t's i nsp'ect .19n,.A. records , and approved 91 ans0a;Mla* ,a va 1Ta6 1 e at the Job ..0 site pr)or to the start of any 0.66- strOCt )on. These doCUMents,,,#rP to be maintained and ,,a01 1-. able un 0 1 0 1 i n PeOtlowi ap p rove.) , is granted. 6 . A l l i,'„donser6otA on to .-'15e' don et7i n . coriMpy-Mance, wi th approved p 1 0'., and requirements - of the Uptf.i5irpi ,E(ull'Oing Code ( t#97 Edition) as aMehded, 'Un tform Pieehan -1-1.3a1 Code (1997 Ed it,io'n and Washington 'State:En'ergk,Code.,1 4997:_Edit ion) , •., • 7. Val Ad i ty.%bf OderM) t.- -Th.,e 4Sivance 'o'f peyMi t or approval , .p 1 ?i3O,.7, , S'Oec, i f ication %, larWCOMputa4ons,ASha 1 I not be con- strued ,tp, be a periitt,,f 66 o r an ,approval r T. of, any 0 ola t tpn 4 , . of any of the ,prov i s i ons of the\l*ild ing-"code, or of 4p-spv , hN other' 4'..-o rdl pence of the Jurisdict 1,16,Np-perm) t prety4ng tap .91 v', am thOro iiy to violate or calice 1/ tl,..pro0,t", Joni.' drg*hish'IN ,;•, 8 . 1 : l t a t 4 1 1 X , 1 3 r : valid. 1 a t )on for tWbu i 1 dtng, i ripeotors review. instruct ions r0q0rPu:: s 1 tel-qi a L / •, '. ' ..', „j- •,, _ ,,,, ,,, ,,),•''';',t,`','9 , ! • ' • CITY OF T" KWILA Permit Centel 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: A Description of work to be done: e /e p',‘ .s '. IL 5Yj - . a7-7 . Ale at) - I to 41E4'1 l Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on se • arate 8 1/2 X 11 •a•erindicatin• • uantitles & Material Safet Data Sheets Value of Construction: ---- Site Address: 7:aF - ---- • ,, 4,-.',' r City S :te /Zip: ' • Tax Parcel Number: 25:0_ 4, ,...., ipigj Property Owner: ,/ �' S Phone: — Q ci,..._1`� ZS -EL .-3 Street Address: /��' / / /�- i 3 ; ,-L- , ve �,Cily St to /Zip: J Y!/�eLt� �/l- r Fax #: Contact Person: f y % ei S� Phone:, 15 SS5 "J` 2- 4 Street Address: 4 . j al City State /Zip: ���� / Fax #: 2 -3-7 Contractor: // Phone: Street Address: • 2 .7 2- - 2 City State /Zip: ./ Fax #: /. g-- -333 —. Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: ,- Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW'AND APPROVAL REQUESTED: (TO BEFILLED OUT BY APPLICANT) , Description of work to be done: e /e p',‘ .s '. IL 5Yj - . a7-7 . Ale at) - I to 41E4'1 l Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on se • arate 8 1/2 X 11 •a•erindicatin• • uantitles & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition ❑ Fence 4,00rMechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting APPLICANT REQUEST FOR MISCELLANEOUS PUBLICWORKS,PERMITSO ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load /Hauling MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Phone: Address: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. afp appdca acceec ■ Date appl{Fation expires: 1C1 Apply ken by: (initials) MISCPMT.DOC 7/11/96 ALL MISCELLANEOUS ' 'MIT APPLICATIONS MUST BE SU . TED WITH THE FOLLOWING: > ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) in SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Submit checklist: No: ' M -9 Above Ground Tanks/Water'Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 �-�G�a Antennas /Satellite Dishes Submit checklist:: No; 'M -1 '. in Awnings /Canopies - No signage • Commercial` Tenant Improvement . Permit .: . Print name: Bulkhead/Dock ; Submit checklist . No M -10 Commercial Reroof Submit checklist'' No M -6': F Demolition Submit checklist • . No: M -3; M -3a ® Fences - Over 6 feet. in. Height Submit checklist No: M -9 ; , Land Altering /Grading /Preloads Submit checklist . No: M -2 in Loading Docks Commercial Tenant Improvement • Permit.. Submit checklist. No: H -17 El Mechanical (Residential & Commercial) Submit checklist.., No. M -8, Residential :only - H -6, H -16 in Miscellaneous; P.ublic,Works Permits Submit checklist; No: H=9 .: El Manufacttered Housing•(RED INSIGNIA ONLY) Submit checklist, No: M -5; Moving. Oversized. Load /Hauling . Submit checklist No: M -5 Parking Lots Submit checklist No: M -4 in Residentlal Reroof - Exempt with following exception: If roof structure to be.repaired or replaced Residential Building Permit Submit checklist .. No:. M -6 0 . Retaining Wails - Over 4 feet in height Submit checklist. No :. M -1 El Temporary: Facilities.' Submit checklist, NO:. M -7 0 Teinporary...Pedestrfaril Protection/Exit Systems,. . Submit checklist No M -4 . ri Tree Cutting Submit checklist • No: M -2 • ' Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building. Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,,or contractor licensed by the State of Washington, a notarized letter from the property: owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. . I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED'AGE 4T: Signature: �-�G�a - tOR Date: ! Print name: -`%�Cl �l, l Ph Q.-- 5 g8 575 i F s 333 `6s6• Address: , ; , City /State /Zip: MISCPMT.DOC 7/11/96 ks4 *kkA•hkhokkAA*k*k*•A•4*A*ANJ'\e:c:I_ 4A.4 k••`•`•k*) A•k4.f A• k• kAk **•k*stk*A:�:A*•k•kA•4*4A.ks4* CITY OF 1 Lli(4 ILA, WA TRANSMIT /r:4h440 hlthkAh•k.kk*.5.4 ..4%kst•.F.k *h•k•AkAhA h AAk&:•.4 .t*4**:k;.*Ahk•kk4,•t*A4kA* 1•RAN;iMx1 Number: R9800054 i4 Amount. 46.50 04/26/99 13.421 Payment Method: CHECK Notation: NC(-1T TRANSFER CU :[nit: Tt»13. Permit No: M99•0077 Type: f •MI:CIi MECHANICAL PERMIT Parcel No: 252304-9071 Site Addren : 1032 INDUSTRY DR Total gees: 46.5,0 This Payment 46.50 Total ALL Pmts: 46.50 Balance: .00 . k At+ AA* A* AA• k +A * *,A* *AAA•AAAyAhAAAA*AAek* AAA *AAA*A *•k *a *AAIV.h cA* *Ak14kA Rc:t;ount Cade 000/3.451:130 • 000;1322..100 Description Amount P.LA.N CHECK -- 'MC1NRC5 .9 „30 t4ECIi4iICAL NONRES 37.20 • INSPECTION NO, INSPECTION RECO Retain a copy with pe)i.wt CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 r.l99' -00-77 PERMIT N (206)431 -3670 Pr f jit: f +- 1 /'" / , �]j T o� spect'on: ,' A dress: d e ����fr� 1/��'% r = . "� �99 Date wanted: too / P.m. Special instructions: / C�. C / Re trs- Requester . yyzaivt Plion 42.G ges z V7 pp" roved per applicable codes. Corrections required prior to approval. COMMENTS: C-77ay S 4.e ,c (r,7-.K. E0 r -bat re, ^ \ f . t� ., n / / In o, A n $47.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: INSPECTION NO, .P44-4•7 ; r,t4; ''C.-4444;4r.".4 INSPECTION RECOcii- Retain a copy with per it CITY OF TUKWILA BUILDING DIVISION 63O'uthcner BIvd, u a, WA 98188 114q--oo72,, PERMIT NO. (206)431-3,670 pz-z-L-xi tw )---:ta7--r Type/Asi8r firioc, Adilrbssez :21/467Z Date called: zy ?/747 Special instructions: Date wanted:4 • . /--' --)//9 Requester: etc/me/la/ Phone: civs gI5- 367/7 Approvedarer applicable codes. COMMENTS: ,Corrections required prior to approval. :7c 1tii1 d'ff,,,e, 71-77 Inspector: -rL L Vd CM $47.00 REINSPECTIO (FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Soutlicenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: Date: te.Fr )..! • Coovc. Copq PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M99 -0077 DATE:. 4 -12 -99 PROJECT NAME: PACIFIC GULF %X Original. Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After Perrnit Is Issued DEPARTMENTS: Buildik6ivision Aux., Public Works ih, AR) Fire Prevention ,y - 4-(3-2/ Structu ar .I Planning Division ❑ Permit Coordinator iL DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete Incomplete Comments: DUE DATE: 4 -13 -99 Not Applicable ❑ TUES /THURS ROUTING: Please Route No further Review Required Routed by Staff E (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 5 -11 -99 Approved ❑ Approved with Conditions, Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions Not Approved (attach comments) REVIEWERS INITIALS: DATE: \PR•ROUTE,DOC 6/98 General Data FIEF CL RECEIVED CITY OF TUKWILA 1T;; 1 2 1999 MODEL RATED VOLTS /PH /HZ A.R.I. RATINGS (COOLINGIO BTUH 18000 Indoor Air Flow (CFM) 600 System Power (KW) 1.93 EER /SEER (BTU /WATT -HR.) 9.35 / 10.00 Noise Rating No. 8.0 A.G.A. RATINGS (HEATING)® (High) Input BTUH 50000 50000 50000 75000 Capacity BTUH ®0 40000 40000 40000 60000 AFUE 78% 78% 78% 78% Temp. Rise °F (Min. /Max.) 30 / 60 30 / 60 30 / 60 35 / 65 (Low) Input BTUH 40000 40000 40000 60000 Capacity BTUHOO 32000 32000 32000 48000 AFUE /CSE 78 %/76% 78%/76% 78 %/76% 78 %/76% Temp. Rise °F (Min. /Max.) 30 - 60 30.60 30 - 60 35 - 65 Type of Gas* NATURAL NATURAL NATURAL NATURAL POWER CONNS. - V /PH /HZ 208-230/1/60 208 - 230/1/60 208- 230/1/60 208 - 230/1/60 Min. Brch, Cir, Ampacity 13.2 15.7 20.1 21.3 Br. Cir. - Max. (Amps) 20 25 30 35 Prot. Rig. - Recmd. (Amps) 20 25 30 35 COMPRESSOR CLIMATUFF'" CLIMATUFF'" CLIMATUFFT CLIMATUFF'" No. Used 1 1 1 1 Volts /PH /HZ 200- 230/1/60 200-230/1/60 200 - 230/1/60 200 - 230/1/60 R.L. Amps - L.R. Arnps 8.0 - 48 10:0 - 67 13.3 - 79 13,5 - 79 OUTDOOR COIL - TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows /F.P.I. 2/15 2/15 2/15 2/15 Face Area (Sq. Ft.) 4.5 4.5 5.43 5.43 Tube Sae (in.) 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER YCC018F1LOB 208 - 230/1/60 YCCO24F1 LOB 208 - 230/1/60 YCC030F1 LOB 208 - 230/1/60 YCC030F1 MOB 208 - 230/1/60 23400 800 2.55 9.10 / 10.00 8.0 29200 1000 3.17 9.20 / 10.00 8.0 29800 1000 3.27 9.10 / 10.00 8.0 INDOOR COIL - TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows /F.P.I. 2/15 3/15 3/15 3/15 Face Area (Sq. Ft.) 3.25 3.25 3.25 3.96 Tube Size (in.) 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER Refrigerant Control CAPILLARY CAPILLARY CAPILLARY CAPILLARY Drain Conn. Sue (in.) 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT Duct Connections SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING OUTDOOR FAN - TYPE PROPELLER PROPELLER PROPELLER PROPELLER No. Used /Oia.(in.) 1/18 1/18 1/18 1/18 Type Drive / No. Speeds DIRECT / 1 DIRECT / 1 DIRECT / 1 DIRECT / 1 No. Motors - HP 1 - 1/5 1 - 1/5 1 -1/5 1 -1/5 Motor Speed R.P.M. 1080 1080 1080 1080 Volts /PH /HZ 200- 230/1/60 230/1/60 230/1/60 230/1/60 F.L. Amps - L.R. Amps 1.6 -3.3 1.6 -3.3 1.8 -3.3 1.6 -33 INDOOR FAN - TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Oia. x Width (in.) 9 X 9 9 X 9 9 X 9 10 X 9 No. Used 1 1 1 1 Drive / Speeds (No.) DIRECT / 2 DIRECT / 2 DIRECT / 2 DIRECT / 2 No. Motors - HP 1 - 1/4 1 - 1/4 1 - 1/4 1 -1/3 Motor Speed R.P.M. 1080 1080 1080 1080 Volts /PII /HZ 200-230/1/60 200. 230/1/60 200 - 230/1/60 200 - 230/1/60 F.L. Amps - L.R. Amps 1.6/1.4 - 2.9 1.6/1.4 - 2.9 1.6/1.4 - 2.9 2.8/2.2 - 5.1 COMBUSTION FAN - TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive - Speeds (No.) DIRECT - 1 DIRECT - 1 DIRECT - 1 DIRECT -1 Motor HP - Speed (RPM) 1/35 - 3480 1/35 - 3480 1/35 - 3480 1/35 - 3480 Volts /PH /HZ 240/1/60 240/1/60 240/1/60 240/1/60 F.L. Amps 0.6 0.6 0.6 0.6 FILTER - FURNISHED? NO NO NO NO Type Recommended THROWAWAY THROWAWAY THROWAWAY THROWAWAY Min. Face Area -Lo (ft.)®® 2.0 2.67 3.33 3.33 REFRIGERANT Charge (Ibs. of R -22)0 3,8 lbs. 4.0 lbs. 4.4 lbs. 4.5 lbs. GAS PIPE SIZE (IN.) 1/2" 1/2" 1/2" 1/2" DIMENSIONS HXWXO HXWXD HXWXD HXWXD Crated (in.) 31-1/4 X 38 X 57 31 -1/4 X 38 X 57 31 -1/4 X 38 X 57 35-1/4 X 38 X 57 Uncrated SEE OUTLINE DRAWING SEE OUTLINE DRAWING ' SEE OUTLINE DRAWING SEE OUTLINE DRAWING WEIGHT Shipping (Ibs.) / Net (Ibs.) 341 / 301 350 / 310 398 / 358 398 / 358 See notes on page 14 8 MC/ a°0(51.7 �t fir) • CONTROL SOX ACCESS PANEL Dimensional Data YCC018 -060F Outline — Front (ALL DIMENSIONS ARE IN INCHES) C HOLE FOR 1/2" CONDUIT (UNIT CONTROL WIRES) 1" DIAMETER K.O. FOR 1/2 N.P,T. GAS CONNECTION AS VALVE ACCESS ONDENSER COIL CONDENSER COIL IN THIS AREA ONLY ON YCC042F -M, RECEIVED YCC048F -M CITY OF TUKVJIIA APR 1 2 1999 PERMIT CENTER MOOEL A B C 0 E F YCC018 /024f•L YCC030F•L 55.1/4 36 25.3/16 12.15/16 36.3/4 KNOCKOUTS FOR 1/2* AND 1' CONDUIT YCC030F•M YCC036F•L /F•M 55.1/4 36 29.3/16 12.15/16 36.3/4 KNOCKOUTS FOR 3/4' AND 1.1/4• CONDUIT YCC036F•H YCC042F•M YCC048F•M 82.3/4 36 29.3/16 14.1/2 27.1/2 KNOCKOUTS FOR 3/4* AND 1.1/4• CONDUIT YCC048F•H YCC060F•M 64.5/16 45 33.3/8 14.13/16 21.15/16 KNOCKOUTS FOR 3 /4'AND 1.1/2' CONDUIT From Dwg. 210661689 Rev, 0 37 Dimensional Data and Weights YCC018 -060F Outline -- Rear (ALL DIMENSIONS ARE IN INCHES) EVAPORATOR COIL & BLOWER PANEL C HORIZONTAL SUPPLY OPENING DOWNFLO SUPPLY OPENING HORIZONTAL RETURN OPENING APPEARANCE SURFACE OF SUPPLY & RETURN PANEL SECT. X -X TYPICAL CROSS SECTION OF SUPPLY & RETURN PERIMETER FLANGES L k M 0IRENS IONAL SURFACE ISEE TABLE I 1S DIA. ENTRY FOR 1/2 N.P.T. CAS CONNECTION CONDENSATE DRAIN FOR 3 \4" FEMALE NPT DOWNFLOW RETURN OPENING SECT Y -Y TYPICAL CROSS SECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES 3 T RECEIVED CITY OF TUKWILA APR 1 2 1999 PERMIT CENTER CABINET MODEL CORNER WEIGHT ILBSI UNIT WEIGHT INETLBS.) A 8 C D E F G H J K L M N P WI W2 W3 W4 A YCC018F•l 683 61.7 84 92.9 307 55.1/4 26 25.3/18 18.9/16 11.1/18 8.9/18 8.13/18 17 21.5/18 25 11.1/2 10 3 4.7/16 YCCO24F4. 69.4 60 0 85 99 5 314 YCCO3OF•l 705 614 87 99.8 319 8 YCC036F•I. 8406 6808 92.1 1137 358 55.1/4 36 29.3/16 18.9/18 11.1/16 6.9/16 6.13/16 17 203/4 25.13/16 17.1/2 10 3 4.7/16 YCC030F•M 78 3 68 3 95.6 109.7 352 19.3/4 24.13/18 YCC036F•M 86 67 6 93 2 115.13 364 C YCC036F•H 90 3 73 8 101 123.7 389 62.3/4 36 29.3/16 18.9/16 11.1/16 6.9/16 11.1/8 17 19.3/4 28.1/4 17.1/2 10 3 8.3/4 YCC042F•M 1037 88.7 988 122.6 412 19.3/4 28.1/4 YCC048F•M 101 6 84 6 102.2 128.4 418 19.3 4 28.1/4 D YCC048F14 123 8 104 6 132 5 157 518 64.5/16 45 33.3/8 21.1/16 151/16 4.15/16 9.1/8 21.15/16 25 29.1/2 20 14 3.1/2 8.5/16 YCC060F•M 135.4 109.8 137 3 169.3 552 25 29.1/2 From Dwg. 21D681690 Rev. 1 38 M99-0077 22 FRINTLD NO 1000i4 CIE ARPRINT - mS /-; , v A. e e4 2 525:it/ ?c:.) 7 /442 Cc re,(x)rc- - / ,-- I FILE COPY und that the Plan Check approvals are subect to errors and orniss ions and approval of \ ndersta p■ani does not authorize the violcept o at;on any aciopted code or ordinance. Be‘i con- Iractor SC of approved plans acknowledged. /. 4(/. 116 .4,01— I By Cate Petc6I 41 - , k1 Ec V 24 4-4,04 SEPARATE PERMIT REQUIRED FOF, 0 ECHANiCAL e p ELECTR ICAL 0 P UMBING GAS VIK-.LiG UJiLDWG DMSiO'i k ?S)RO\I D OR 1 S 1999 ---7,;A,Lc)‘NC; ONtSkON 0 ? , RECEIVED CITY OF TUKWILA PERMIT CENTER M141-0013 CONTRACTOR HEAT tRANSFER COMPANY BOX 1268 CARNATION