HomeMy WebLinkAboutPermit M99-0077 - PACIFIC GOLF.r.
M99 -0077
•
1032 Industry Dr.
Pacific Golf
City of Tukwila L.
(206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
MECHANICAL PERMIT
Permit No: M99 -0077
Type: B -MECH
Category: NRES
Address: 1032 INDUSTRY DR
Location:
Parcel #: 252304 -907]
Contractor License No: HEATT* *20600
TENANT PACIFIC GULF
1032 INDUSTRY DR, TUKWILA, WA 98188
OWNER PACIFIC GULF PROPERTIES
631 STRANGER BLVD, TUKWILA WA 98188
CONTACT TOM MCLOSKEY
BOX 1268, CARNATION, WA 98014
CONTRACTOR HEATTRANSFER COMPANY
PO BOX 1268, CARNATION WA 98014
*** k*********************.********************** * * **•*k** * * ** * * * ** *** * * * *k *•k*
Permit Description:
Status: ISSUED
Issued; 04/26/1999
Expires: 10/23/1999
Phone:
Phone: (206)575 -0765
Phone: 425 - 885 -3247
Phone: 425 885 -3247
REPLACE EXISTING HEAT SYSTEM WITH NEW. ELECTRIC TO
GAS CHANGEOUT.
UMC Edition: 1997 Valuation:
Total Permit Fee:
5,000.00
46.50
• k******.• k********.***********' k*• k****•* * * *. * **•k * * **•k * * * **** ** * *•k * ** k* * * * * * * *•k k*
-4 2-(P - Cj
Permit CenteU Authorized Signature Date
I hereby certify that 1 have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will he complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. 1 ani authorized to sign for and
obtain this building permit.
Date:
Print N a m e:- 7��� _/"/P ° Title: 46 _ �
This permit shall become null and void if the •work is not commenced within
180 days from the date of issuance, or •,if.the work is suspended or
abandoned for a period of 180•days•from the last inspection.
CITY OF TUKWILA
Address: 1032 INDUSTRY DR Permit No: M99-0077
Su i te :
Tenant: PACIFIC GULF , , Status: ISSUED .
Type: 8-MECH App 1 ied: 04/12/1999
Parcel #: 252304-9071 Issued: 04/26/1999
**********-k************.k*****************************A*****.h***************
Permit Condi t ions:
1. Any expoSed insulations backing material 'hi1 have a 'Flame
.Spread Rat ing of 25 or 1 ess,,rand,Tplatex i a 1 sha 11 bear i dent i -
J i c t i o n s h o w n g the J...ire719::IvitpEmi'n2&!,:p4r19 thereof
2:. Plumbing permi ts ;400qilj4-66Ealned 1fil-01-14iupreSeatt 1 e-Ki ng
.County Depar tment4gf:-:Pub, 1 ii,p 1,!110,a I tr PlumbT6-670:11t1 be
inspected by tfiW"'ag#rfc,A., .•;i nt 1 u d 10 tt a. 1 1 4..s,, p fonk,
(296-471'2) .,V.-,-' ,,,,,, ",:.;!;) -Y q,,
3. El ectr i calp,ei...m i t:7;:',0a,1 V be obta)ned" through the Washington
State D iy.,;,t,,FA on of ''I,bor and 'jft.i'a usir fe S', and a11,61,ec 64) , •
work w tpb e.,:.',.)ns:', 0 et': t 0; by or)'0A ag en cy (24t3-6630..
4. No changes wi 11,,,be made to the ;Plans un 1e approt*ed!:.p.).-i,,,,Ow.
Engine and the Tbkwi la iil,U tl ding ';Division.
5. All 0 Orin 1t's i nsp'ect .19n,.A. records , and approved 91 ans0a;Mla*
,a va 1Ta6 1 e at the Job ..0 site pr)or to the start of any 0.66-
strOCt )on. These doCUMents,,,#rP to be maintained and ,,a01 1-.
able un 0 1 0 1 i n PeOtlowi ap p rove.) , is granted.
6 . A l l i,'„donser6otA on to .-'15e' don et7i n . coriMpy-Mance, wi th approved
p 1 0'., and requirements - of the Uptf.i5irpi ,E(ull'Oing Code ( t#97
Edition) as aMehded, 'Un tform Pieehan -1-1.3a1 Code (1997 Ed it,io'n
and Washington 'State:En'ergk,Code.,1 4997:_Edit ion) ,
•.,
•
7. Val Ad i ty.%bf OderM) t.- -Th.,e 4Sivance 'o'f peyMi t or approval
,
.p 1 ?i3O,.7, , S'Oec, i f ication %, larWCOMputa4ons,ASha 1 I not be con-
strued
,tp, be a periitt,,f 66 o r an ,approval r T. of, any 0 ola t tpn 4
, .
of any of the ,prov i s i ons of the\l*ild ing-"code, or of 4p-spv , hN
other' 4'..-o rdl pence of the Jurisdict 1,16,Np-perm) t prety4ng tap
.91 v', am thOro iiy to violate or calice 1/ tl,..pro0,t", Joni.' drg*hish'IN
,;•,
8 . 1 : l t a t 4 1 1 X , 1 3 r : valid.
1 a t )on
for tWbu i 1 dtng, i ripeotors review.
instruct ions r0q0rPu:: s 1 tel-qi
a L / •, '. ' ..', „j-
•,,
_ ,,,, ,,, ,,),•''';',t,`','9 , !
• '
•
CITY OF T" KWILA
Permit Centel
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Miscellaneous Permit Application
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
Project Name/Tenant: A
Description of work to be done: e /e p',‘ .s '. IL 5Yj - . a7-7 . Ale at)
- I to 41E4'1 l
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no
Attach list of materials and storage location on se • arate 8 1/2 X 11 •a•erindicatin• • uantitles & Material Safet Data Sheets
Value of Construction:
----
Site Address:
7:aF
-
---- • ,, 4,-.','
r City S :te /Zip:
' •
Tax Parcel Number:
25:0_ 4, ,...., ipigj
Property Owner: ,/
�'
S
Phone: — Q ci,..._1`�
ZS -EL .-3
Street Address:
/��'
/
/ /�-
i 3 ; ,-L- , ve
�,Cily St to /Zip:
J Y!/�eLt� �/l-
r
Fax #:
Contact Person:
f y % ei S�
Phone:,
15 SS5 "J` 2-
4
Street Address:
4 . j
al City State /Zip:
���� /
Fax #:
2 -3-7
Contractor: //
Phone:
Street Address:
•
2 .7
2- -
2 City State /Zip:
./
Fax #: /.
g-- -333 —.
Architect:
Phone:
Street Address:
City State /Zip:
Fax #:
Engineer:
Phone: ,-
Street Address:
City State /Zip:
Fax #:
MISCELLANEOUS PERMIT REVIEW'AND APPROVAL REQUESTED: (TO BEFILLED OUT BY APPLICANT) ,
Description of work to be done: e /e p',‘ .s '. IL 5Yj - . a7-7 . Ale at)
- I to 41E4'1 l
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no
Attach list of materials and storage location on se • arate 8 1/2 X 11 •a•erindicatin• • uantitles & Material Safet Data Sheets
■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof
❑ Demolition ❑ Fence 4,00rMechanical ❑ Manufactured Housing - Replacement only
❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems
❑ Temporary Facilities ❑ Tree Cutting
APPLICANT REQUEST FOR MISCELLANEOUS PUBLICWORKS,PERMITSO
❑ Channelization /Striping
❑ Flood Control Zone
❑ Landscape Irrigation
❑ Storm Drainage
❑ Water Meter /Exempt #
❑ Water Meter /Permanent #
❑ Water Meter Temp #
❑ Miscellaneous
❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s):
❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft grading /clearing
❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Street Use ❑ Water Main Extension 0 Private 0 Public
0 Deduct 0 Water Only
Size(s):
Size(s):
Size(s): Est. quantity: gal Schedule:
❑ Moving Oversized Load /Hauling
MONTHLY SERVICE BILLINGS TO:
Name:
Phone:
Address:
City /State /Zip:
0 Water
0 Sewer
0 Metro
0 Standby
WATER METER DEPOSIT /REFUND BILLING:
Name:
Phone:
Address:
City /State /Zip:
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall
expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days
upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application
shall be extended more than once.
afp appdca acceec
■
Date appl{Fation expires: 1C1 Apply ken by: (initials)
MISCPMT.DOC 7/11/96
ALL MISCELLANEOUS ' 'MIT APPLICATIONS MUST BE SU . TED WITH THE FOLLOWING:
> ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
• BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
• ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT
> STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON
LICENSED STRUCTURAL ENGINEER
> CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER
(P.E.)
in
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR
PERMIT REVIEW
Submit checklist: No: ' M -9
Above Ground Tanks/Water'Tanks - Supported directly upon grade
exceeding 5,000 gallons and a ratio of height to diameter or width
which exceeds 2:1
�-�G�a
Antennas /Satellite Dishes
Submit checklist:: No; 'M -1 '.
in
Awnings /Canopies - No signage •
Commercial` Tenant Improvement .
Permit .: .
Print name:
Bulkhead/Dock ;
Submit checklist . No M -10
Commercial Reroof
Submit checklist'' No M -6':
F
Demolition
Submit checklist • . No: M -3; M -3a
®
Fences - Over 6 feet. in. Height
Submit checklist No: M -9
; ,
Land Altering /Grading /Preloads
Submit checklist . No: M -2
in
Loading Docks
Commercial Tenant Improvement •
Permit.. Submit checklist. No: H -17
El
Mechanical (Residential & Commercial)
Submit checklist.., No. M -8,
Residential :only - H -6, H -16
in
Miscellaneous; P.ublic,Works Permits
Submit checklist; No: H=9 .:
El
Manufacttered Housing•(RED INSIGNIA ONLY)
Submit checklist, No: M -5;
Moving. Oversized. Load /Hauling .
Submit checklist No: M -5
Parking Lots
Submit checklist No: M -4
in
Residentlal Reroof - Exempt with following exception: If roof structure
to be.repaired or replaced
Residential Building Permit
Submit checklist .. No:. M -6
0
. Retaining Wails - Over 4 feet in height
Submit checklist. No :. M -1
El
Temporary: Facilities.'
Submit checklist, NO:. M -7
0
Teinporary...Pedestrfaril Protection/Exit Systems,. .
Submit checklist No M -4 .
ri
Tree Cutting
Submit checklist • No: M -2 • '
Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
Building. Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,,or contractor licensed
by the State of Washington, a notarized letter from the property: owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal. .
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS
PERMIT.
BUILDING OWNER OR AUTHORIZED'AGE 4T:
Signature:
�-�G�a
- tOR
Date: !
Print name:
-`%�Cl �l,
l
Ph Q.--
5 g8 575 i
F
s 333 `6s6•
Address:
,
; ,
City /State /Zip:
MISCPMT.DOC 7/11/96
ks4 *kkA•hkhokkAA*k*k*•A•4*A*ANJ'\e:c:I_ 4A.4 k••`•`•k*) A•k4.f A• k• kAk **•k*stk*A:�:A*•k•kA•4*4A.ks4*
CITY OF 1 Lli(4 ILA, WA
TRANSMIT
/r:4h440 hlthkAh•k.kk*.5.4 ..4%kst•.F.k *h•k•AkAhA h AAk&:•.4 .t*4**:k;.*Ahk•kk4,•t*A4kA*
1•RAN;iMx1 Number: R9800054 i4 Amount. 46.50 04/26/99 13.421
Payment Method: CHECK Notation: NC(-1T TRANSFER CU :[nit: Tt»13.
Permit No: M99•0077 Type: f •MI:CIi MECHANICAL PERMIT
Parcel No: 252304-9071
Site Addren : 1032 INDUSTRY DR
Total gees: 46.5,0
This Payment 46.50 Total ALL Pmts: 46.50
Balance: .00 .
k At+ AA* A* AA• k +A * *,A* *AAA•AAAyAhAAAA*AAek* AAA *AAA*A *•k *a *AAIV.h cA* *Ak14kA
Rc:t;ount Cade
000/3.451:130 •
000;1322..100
Description Amount
P.LA.N CHECK -- 'MC1NRC5 .9 „30
t4ECIi4iICAL NONRES 37.20
•
INSPECTION NO,
INSPECTION RECO
Retain a copy with pe)i.wt
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
r.l99' -00-77
PERMIT N
(206)431 -3670
Pr f jit: f +-
1
/'" / ,
�]j
T o� spect'on:
,'
A dress:
d e ����fr� 1/��'% r
= .
"� �99
Date wanted:
too / P.m.
Special instructions: / C�.
C /
Re trs-
Requester . yyzaivt
Plion
42.G ges z V7
pp" roved per applicable codes.
Corrections required prior to approval.
COMMENTS:
C-77ay
S
4.e ,c (r,7-.K. E0
r -bat re,
^
\
f .
t�
.,
n /
/
In o, A
n $47.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
Receipt No:
Date:
INSPECTION NO,
.P44-4•7 ; r,t4; ''C.-4444;4r.".4
INSPECTION RECOcii-
Retain a copy with per it
CITY OF TUKWILA BUILDING DIVISION
63O'uthcner BIvd, u a, WA 98188
114q--oo72,,
PERMIT NO.
(206)431-3,670
pz-z-L-xi tw )---:ta7--r
Type/Asi8r firioc,
Adilrbssez
:21/467Z
Date called: zy ?/747
Special instructions:
Date wanted:4 • .
/--' --)//9
Requester:
etc/me/la/
Phone: civs gI5- 367/7
Approvedarer applicable codes.
COMMENTS:
,Corrections required prior to approval.
:7c 1tii1
d'ff,,,e,
71-77
Inspector:
-rL L Vd CM
$47.00 REINSPECTIO (FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Soutlicenter Blvd., Suite 100. Call to schedule reinspection.
Date:
Receipt No:
Date:
te.Fr )..! •
Coovc. Copq
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M99 -0077 DATE:. 4 -12 -99
PROJECT NAME: PACIFIC GULF
%X Original. Plan Submittal Response to Incomplete Letter
Response to Correction Letter # Revision # After Perrnit Is Issued
DEPARTMENTS:
Buildik6ivision
Aux.,
Public Works
ih,
AR)
Fire Prevention
,y - 4-(3-2/
Structu ar .I
Planning Division ❑
Permit Coordinator
iL
DETERMINATION OF COMPLETENESS: (Tues, Thurs)
Complete Incomplete
Comments:
DUE DATE: 4 -13 -99
Not Applicable ❑
TUES /THURS ROUTING: Please Route No further Review Required
Routed by Staff E (if routed by staff, make copy to master file and enter into Sierra)
REVIEWERS INITIALS: DATE:
APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 5 -11 -99
Approved ❑ Approved with Conditions,
Not Approved (attach comments) ❑
REVIEWERS INITIALS: DATE:
CORRECTION DETERMINATION:
DUE DATE:
Approved ❑ Approved with Conditions Not Approved (attach comments)
REVIEWERS INITIALS:
DATE:
\PR•ROUTE,DOC
6/98
General
Data
FIEF CL
RECEIVED
CITY OF TUKWILA
1T;; 1 2 1999
MODEL
RATED VOLTS /PH /HZ
A.R.I. RATINGS (COOLINGIO
BTUH 18000
Indoor Air Flow (CFM) 600
System Power (KW) 1.93
EER /SEER (BTU /WATT -HR.) 9.35 / 10.00
Noise Rating No. 8.0
A.G.A. RATINGS (HEATING)®
(High) Input BTUH 50000 50000 50000 75000
Capacity BTUH ®0 40000 40000 40000 60000
AFUE 78% 78% 78% 78%
Temp. Rise °F (Min. /Max.) 30 / 60 30 / 60 30 / 60 35 / 65
(Low) Input BTUH 40000 40000 40000 60000
Capacity BTUHOO 32000 32000 32000 48000
AFUE /CSE 78 %/76% 78%/76% 78 %/76% 78 %/76%
Temp. Rise °F (Min. /Max.) 30 - 60 30.60 30 - 60 35 - 65
Type of Gas* NATURAL NATURAL NATURAL NATURAL
POWER CONNS. - V /PH /HZ 208-230/1/60 208 - 230/1/60 208- 230/1/60 208 - 230/1/60
Min. Brch, Cir, Ampacity 13.2 15.7 20.1 21.3
Br. Cir. - Max. (Amps) 20 25 30 35
Prot. Rig. - Recmd. (Amps) 20 25 30 35
COMPRESSOR CLIMATUFF'" CLIMATUFF'" CLIMATUFFT CLIMATUFF'"
No. Used 1 1 1 1
Volts /PH /HZ 200- 230/1/60 200-230/1/60 200 - 230/1/60 200 - 230/1/60
R.L. Amps - L.R. Arnps 8.0 - 48 10:0 - 67 13.3 - 79 13,5 - 79
OUTDOOR COIL - TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN
Rows /F.P.I. 2/15 2/15 2/15 2/15
Face Area (Sq. Ft.) 4.5 4.5 5.43 5.43
Tube Sae (in.) 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER
YCC018F1LOB
208 - 230/1/60
YCCO24F1 LOB
208 - 230/1/60
YCC030F1 LOB
208 - 230/1/60
YCC030F1 MOB
208 - 230/1/60
23400
800
2.55
9.10 / 10.00
8.0
29200
1000
3.17
9.20 / 10.00
8.0
29800
1000
3.27
9.10 / 10.00
8.0
INDOOR COIL - TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN
Rows /F.P.I. 2/15 3/15 3/15 3/15
Face Area (Sq. Ft.) 3.25 3.25 3.25 3.96
Tube Size (in.) 3/8 COPPER 3/8 COPPER 3/8 COPPER 3/8 COPPER
Refrigerant Control CAPILLARY CAPILLARY CAPILLARY CAPILLARY
Drain Conn. Sue (in.) 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT 3/4" FEMALE NPT
Duct Connections SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING
OUTDOOR FAN - TYPE PROPELLER PROPELLER PROPELLER PROPELLER
No. Used /Oia.(in.) 1/18 1/18 1/18 1/18
Type Drive / No. Speeds DIRECT / 1 DIRECT / 1 DIRECT / 1 DIRECT / 1
No. Motors - HP 1 - 1/5 1 - 1/5 1 -1/5 1 -1/5
Motor Speed R.P.M. 1080 1080 1080 1080
Volts /PH /HZ 200- 230/1/60 230/1/60 230/1/60 230/1/60
F.L. Amps - L.R. Amps 1.6 -3.3 1.6 -3.3 1.8 -3.3 1.6 -33
INDOOR FAN - TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
Oia. x Width (in.) 9 X 9 9 X 9 9 X 9 10 X 9
No. Used 1 1 1 1
Drive / Speeds (No.) DIRECT / 2 DIRECT / 2 DIRECT / 2 DIRECT / 2
No. Motors - HP 1 - 1/4 1 - 1/4 1 - 1/4 1 -1/3
Motor Speed R.P.M. 1080 1080 1080 1080
Volts /PII /HZ 200-230/1/60 200. 230/1/60 200 - 230/1/60 200 - 230/1/60
F.L. Amps - L.R. Amps 1.6/1.4 - 2.9 1.6/1.4 - 2.9 1.6/1.4 - 2.9 2.8/2.2 - 5.1
COMBUSTION FAN - TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
Drive - Speeds (No.) DIRECT - 1 DIRECT - 1 DIRECT - 1 DIRECT -1
Motor HP - Speed (RPM) 1/35 - 3480 1/35 - 3480 1/35 - 3480 1/35 - 3480
Volts /PH /HZ 240/1/60 240/1/60 240/1/60 240/1/60
F.L. Amps 0.6 0.6 0.6 0.6
FILTER - FURNISHED? NO NO NO NO
Type Recommended THROWAWAY THROWAWAY THROWAWAY THROWAWAY
Min. Face Area -Lo (ft.)®® 2.0 2.67 3.33 3.33
REFRIGERANT
Charge (Ibs. of R -22)0 3,8 lbs. 4.0 lbs. 4.4 lbs. 4.5 lbs.
GAS PIPE SIZE (IN.) 1/2" 1/2" 1/2" 1/2"
DIMENSIONS HXWXO HXWXD HXWXD HXWXD
Crated (in.) 31-1/4 X 38 X 57 31 -1/4 X 38 X 57 31 -1/4 X 38 X 57 35-1/4 X 38 X 57
Uncrated SEE OUTLINE DRAWING SEE OUTLINE DRAWING ' SEE OUTLINE DRAWING SEE OUTLINE DRAWING
WEIGHT
Shipping (Ibs.) / Net (Ibs.) 341 / 301 350 / 310 398 / 358 398 / 358
See notes on page 14
8 MC/ a°0(51.7
�t
fir)
•
CONTROL SOX
ACCESS PANEL
Dimensional
Data
YCC018 -060F Outline — Front
(ALL DIMENSIONS ARE IN INCHES)
C
HOLE FOR 1/2" CONDUIT
(UNIT CONTROL WIRES)
1" DIAMETER K.O.
FOR 1/2 N.P,T.
GAS CONNECTION
AS VALVE
ACCESS
ONDENSER COIL
CONDENSER COIL IN THIS
AREA ONLY ON YCC042F -M, RECEIVED
YCC048F -M CITY OF TUKVJIIA
APR 1 2 1999
PERMIT CENTER
MOOEL
A
B
C
0
E
F
YCC018 /024f•L
YCC030F•L
55.1/4
36
25.3/16
12.15/16
36.3/4
KNOCKOUTS FOR 1/2* AND 1' CONDUIT
YCC030F•M
YCC036F•L /F•M
55.1/4
36
29.3/16
12.15/16
36.3/4
KNOCKOUTS FOR 3/4' AND 1.1/4• CONDUIT
YCC036F•H
YCC042F•M
YCC048F•M
82.3/4
36
29.3/16
14.1/2
27.1/2
KNOCKOUTS FOR 3/4* AND 1.1/4• CONDUIT
YCC048F•H
YCC060F•M
64.5/16
45
33.3/8
14.13/16
21.15/16
KNOCKOUTS FOR 3 /4'AND 1.1/2' CONDUIT
From Dwg. 210661689 Rev, 0
37
Dimensional Data
and Weights
YCC018 -060F Outline -- Rear
(ALL DIMENSIONS ARE IN INCHES)
EVAPORATOR COIL &
BLOWER PANEL
C
HORIZONTAL
SUPPLY
OPENING
DOWNFLO
SUPPLY
OPENING
HORIZONTAL
RETURN OPENING
APPEARANCE SURFACE
OF SUPPLY & RETURN
PANEL
SECT. X -X
TYPICAL CROSS SECTION
OF SUPPLY & RETURN
PERIMETER FLANGES
L k M
0IRENS IONAL
SURFACE ISEE
TABLE I
1S DIA. ENTRY
FOR 1/2 N.P.T.
CAS CONNECTION
CONDENSATE DRAIN
FOR 3 \4" FEMALE NPT
DOWNFLOW RETURN
OPENING
SECT Y -Y
TYPICAL CROSS SECTION
OF DOWNFLOW SUPPLY &
RETURN PERIMETER FLANGES
3
T RECEIVED
CITY OF TUKWILA
APR 1 2 1999
PERMIT CENTER
CABINET
MODEL
CORNER WEIGHT ILBSI
UNIT WEIGHT
INETLBS.)
A
8
C
D
E
F
G
H
J
K
L
M
N
P
WI
W2
W3
W4
A
YCC018F•l
683
61.7
84
92.9
307
55.1/4
26
25.3/18
18.9/16
11.1/18
8.9/18
8.13/18
17
21.5/18
25
11.1/2
10
3
4.7/16
YCCO24F4.
69.4
60 0
85
99 5
314
YCCO3OF•l
705
614
87
99.8
319
8
YCC036F•I.
8406
6808
92.1
1137
358
55.1/4
36
29.3/16
18.9/18
11.1/16
6.9/16
6.13/16
17
203/4
25.13/16
17.1/2
10
3
4.7/16
YCC030F•M
78 3
68 3
95.6
109.7
352
19.3/4
24.13/18
YCC036F•M
86
67 6
93 2
115.13
364
C
YCC036F•H
90 3
73 8
101
123.7
389
62.3/4
36
29.3/16
18.9/16
11.1/16
6.9/16
11.1/8
17
19.3/4
28.1/4
17.1/2
10
3
8.3/4
YCC042F•M
1037
88.7
988
122.6
412
19.3/4
28.1/4
YCC048F•M
101 6
84 6
102.2
128.4
418
19.3 4
28.1/4
D
YCC048F14
123 8
104 6
132 5
157
518
64.5/16
45
33.3/8
21.1/16
151/16
4.15/16
9.1/8
21.15/16
25
29.1/2
20
14
3.1/2
8.5/16
YCC060F•M
135.4
109.8
137 3
169.3
552
25
29.1/2
From Dwg. 21D681690 Rev. 1
38
M99-0077
22 FRINTLD NO 1000i4 CIE ARPRINT
- mS
/-;
,
v A. e e4
2 525:it/ ?c:.)
7
/442 Cc
re,(x)rc-
-
/
,--
I
FILE COPY
und that the Plan Check approvals are
subect to errors and orniss ions and approval of
\ ndersta
p■ani does not authorize the violcept o at;on any
aciopted code or ordinance. Be‘i con-
Iractor SC of approved plans acknowledged.
/. 4(/.
116 .4,01— I
By
Cate
Petc6I
41 -
, k1
Ec
V
24 4-4,04
SEPARATE PERMIT
REQUIRED FOF,
0 ECHANiCAL
e p ELECTR ICAL
0 P UMBING
GAS VIK-.LiG
UJiLDWG DMSiO'i
k ?S)RO\I D
OR 1 S 1999
---7,;A,Lc)‘NC; ONtSkON
0 ? ,
RECEIVED
CITY OF TUKWILA
PERMIT CENTER
M141-0013
CONTRACTOR HEAT tRANSFER COMPANY
BOX 1268 CARNATION