Loading...
HomeMy WebLinkAboutPermit M99-0081 - SOUTHCENTER MALL - RAINFOREST CAFEM99 -0081 296 Southcenter Mall Rainforest Cafe City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M99 -0081 Type: B -MECH Category: NRES Address: 296 SOUTHCENTER MALL Location: Parcel #: 262304 -9004 Contractor License No: PCLCOSI099NW Status: ISSUED Issued: 05/20/1999 Expires: 11/16/1999 TENANT RAINFOREST CAFE Phone: 290 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT DOUG ORGAN Phone: 206- 988 -0726 290 SOUTHCENTER MALL, TUKWILA, WA 98188 CONTRACTOR P C L CONSTRUCTION SRVC INC Phone: 425 - 454 -8020 PO BOX 52868, BELLEVUE WA 9801.5 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALLATION OF KITCHEN HOOD AND UDS SYSTEM. UMC Edition: 1997 Valuation: Total Permit Fee: 50,000.00 65.06 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** thorized Signature Date -211 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this buding perm Signature: Print Name:_ Date : _ - ,iKtiy.22 OJ9? T i t l e:_ i r=.`�gssca This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY (iF TUK44ILA Address: 296 SOUTHCENTER MALL Suitel Tenant AINFOREST CAFE Type: R• -MECH Parcel 441 2623041-9004 Permit No: M99 -0081 Status: • APPROVED Applied: 04/1.5/1999 Issued: *****'• k***********• k***• k***• k*** k********** k******* *.** *•k* * * *•k* *•k * * *** * *** *•k *fie* Perinit Cond itionsd 1, Electrical permits shall be obtained through the Washington State Division of Labor and I,icLu.s.t.ri.,z,s and all el ectrical work wi11 be inspected, bty>1tha,t"4sal'� Cr21 3a::,E,C30). 2 No..'changea w i l l be,,�in de.;:to- ^'iil'ie plans Unzl ~e,; . ap,p ^ovod by the Eng in eer and the, uk.,wila 13 u irld`i ng Pi`., v i s i ori., ',.' ►,, S. Al 1 perm i ts, it s i,e• "t ion i e ot'ld"' , ui . approved' ;ai t. „„ s'ial 1 be ;,available at „th'e jol? sirte \rpir.i o the st'art'.taaof. any ; kcon - ' ,�, o•ww't�ci 'struct i an .4:X Wee 5e�xx;dtcy,Oin.e"'rits are;,ilp✓' be ma irita'i'nad'. ar d:� v. a i -1 able ur►t1,rl:4inal i,tn.spec•t;1or►; a'pprcry'd`1'is;,,gianbed ' _,.,r. � . ;.(a1 1 construct l;an to;, be.. .,dcine i n , con f ormance� ..0 i th' ;approvcncl 4p1 ans a;r cJ. r'equ'i`emen:t"s of the 'tIrti form Du i 1 d i�n9g Code ,(;199., 7 'Edits 'i,6'/'as amen'ded', Uni;:for';i Mecha'n cal Code (1997 Editi6 :n) :and 4l;a•shin,gton State Ene'r'gY'.Code (:1`997 Edition) ,..,,,s' . �. ;Val id :by of .Perm•it. .The issll;e`tn,ce of a permit; or''app'rcival: 1p1 an ,.:� sper'i,,•r i cat ions, ,and co'm'putat;i:ons shat 1 riot ;be :c0fl., stru'ed to, be a '�'permi t"..,for, o;•r' an a'ppi"oval of , any v.i of at.,i.o o f 'any y o f 'the jar o v ai; s''i' , n't; :. ,o f ;' :t Me b u s 'l d' i rig ' °;c.o d e or o f "'..any,, t.. other;? ord irlpnc.e o f . -the "` 7ui ^ris;'d1c.ti:CJrn No pe ;rmit pi esumrii q give` aut�ho,r ;'sty sto ..v..7o_late ar; cance'1,; tPI'ee )rJ visions of This'. cod yshal 1 be`=va.1 i..d. R Y ,'., fa. laf1I1'yact err installa.t`1on 'xtn tru5ct idn'i required on sit'e for.: the b 11 ding i:,r1spec,tor,s- revtiew.' yo-,._ CITY OF TI" WWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: RA II0oRtr- CAFE / Val a of Construction: Site Address: 260 Go LerfricavreiL vytA'U. 7 ,v LA. City State /Zip: Tax Parc Number: Property Owner: iyE i 416.05 L . (oB5 ti p.ouiN / s4jc • 0n Phone: 2/&*" 57/ - yU Street catiTerz Rot, „) Ext b • r City State /Zip: C Fax #: Contact Person: PAul, RAGO 7.1 CuNINGNPw. Grou P Phone: wz — 37 9- 3y 60 i Street Address: City State /Zip: 201 �Alx! s`r s ml�I,ii �4 -Pons , >�►fy Fax #: Contractor: CL COIIlS J f g P �ucr� Glv s��.Ir �Es INC . sy� y Phone: Fax #: W2188-9'2°0 Street Address: City State /Zip: X330 ohm Ave / 64.004IW6YDAJ n 1 lu 5i/3/ Architect: S% Cc& -( PEi25bt\1. Phone: Street Address: City State /Zip: Fax #: RECEIVED CITY OF TUKWILA Engineer: ^ //A_ U Phone: APR 1 5 1999 Street Address: City State /Zip: Fax #: PERMIT CENTER MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) . . Description of work to be done: TN5rAt l- ON or iorLNf v yQoj + uLyj 511570/1/k Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes ❑ Bulkhead /Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence ,Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting APPLICANT: REQUEST. FOR'MISCELLANEOUSPUBLIO WORKS: PERMITS' ❑ Channelization /Striping ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public Cl Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): MONTHLY SERVICE BILLINGS TO: Date application expires: Applicall. Name: :n by: (initials) Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Phone: Address: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and Is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale application accepted: 1 Date application expires: Applicall. t: :n by: (initials) MISCPMT.DOC 7/11/96 ALL MISCELLANEOUS • RMIT APPLICATIONS MUST BE SU• ITTED WITH THE FOLLOWING: ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) 0 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Submit checklist; : No: "': M -9" Above Groltnd Tanks/Water Tank's- Supported directly lipon grade exceeding 5,000 gallons and a ratio of height to diameter or Width, which exceeds 2:1 0 Antennas /Satellite Dishes Submit checklist No M -1 EI AWhings /Canopies - 'NO signage Commercial Tenant.Improvement" Permit 0 Bulkhead/Dock Submit checklist No M -10 0 Commercial Reroof "Submit checklist: No M -6 Demolition: Submit checklist No: M 3; .'M -3a,. 0 Fences - Mier 6 feet in Height Submit checklist: No ;M =9° Land AlteringiGrading/Preloads . Submit checklist ,. No: M -2 in Loading;Docks . , Commercial Tenantlmprovement -.:: Permit:., Subrtiit checklist No: N1.7:... 0 ' Mechanlcal'(lResidential;& Commercial) Submit checklist `',No:: M =8, Residential only = H -6; H -16 : Submit checklist No: H -9. fl Miscellaneous Public Works Permits, ri Manutacttired Housing.(RED`INSIGNIA ONLY) Submit checklist No M 5- Moving :OVersized :Load /Hailling Submit checklist :No: ' M -5 '' J Parking Lots . Submit checklist . No: M -4. Residential Retool - Exernpt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist .:"No: M -6 0 Retaining Walls - Over 4 feet in height Submit checklist No M -1 0 Temporary Facilities Submit checklist No M-7 c Temporary Pedestrian Protection/Exit Systems Submit checklist No :.. M -4 O Tree Cutting Submit checklist : No M -2 Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Bulld/ng;Owner /Authorized Agent. .1!the applicant is other than the owner, registered archi tect lengineer,;or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and: obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING "O ER OR AUTHORIZED AG NT: Signature: �. Date: q /- 7 !t Print name: et?-6,14Y Ne..�, tT Phone: / IZ�6 Fax #:614-- 8,68-4977 mit .5,5„..113( Address: 9330 z -it me5 74116- so /` ' city istatteeRp 04 1060, MISCPMT.DOC 7/11/96 INSPE TION NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION REC, ^RD Retain a copy witliy_�rmit AM-ow/ PERMIT NO; _(206)431 -3670 Proj: _���� s� of I � ction;! Address: '29' d— G..c 04 '4tJL 'Date-cat e1eir- Special instructions: Date war ee Z CO a.m. p.m. Reque v_ aole i Phone: W/; pproved per applicable codes, COMMENTS: Corrections required prior to approval. (37z 7'D (:-/-t4i•e____ Date $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No: Date: INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RECD Retain a copy with einit 444t-44'p :. PERMIT NO.-"' (206)431 -3670 Pro e i n.! s T T p f Ins ectio y cY� X RU-- G7— /e-t Address: 290 Sc /047-,C.-. Date called: Special instructions: Date wanted: z �I � a.m. p.m. Request ] /144 0 Phone: EApproved per applicable codes. corrections required prior to approval. COMMENTS: / tthe y o ,'c7/ /,'$)C74'/-S x;, ,e__ P ' ' c 7 --7 ,� ,s ' J 0 t/ ( ' 4•,4i2i t 6 • G4-, X /a/Ali+l41C7 /2-4:. 0 1.-ii ,zei-e- Z._,ft._ /75 ?6g, • /,L 1 'F %,//- &///6// - % 4 «d� do Dat El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: _liiri _.'r:A xy.fs *Si hait' AMY. ..::h11s{1��+'t'!"'4:i.v:i %.L.s .'. "Ik.r , dAV;A s2c i},:-. 3 .r.'+ti'fi:Seak...c..ii:%'. -:L4 `SAi i.SttVV-•:J,.:, n`� : '" : . „.. City of da - - . • - • Fire Department - . Til*W/LA FIRE,DEPARTMENT FINAL APPROVAL -- • John W. Rants, Mayor Thomas P. Keefe, Fire Chief Project Name Address 9■9 SerG1/4\t•c-S6r. ACP CN LL. Suite # - Retain current -In6P-eb.ti6iTiai-e-aiii-e- Needs shift inspection • • • 5.1., Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature e FINALAPP.FRM 5 lo 671 ZAAC>fl Date Rev. 2/19/98 • T.F.D. Form F.P. 85 Headquarters Station:. 444Andover Park East • Tukwila,:WashingtOn 98188 • Pnone: (206) 575-4404 • Fax (206) 5754439 MAY -13 -1999 14:34 AC AND S, INC. Le/13/199B 12:27 423743 yi1. CITY FETUKWILA MAY 1 4 1999 PERMIT CENTER FIBER SLEEVE' PREMIER r"RWIN PAM SUGGESTO INSTALLATION FOR PYROSCAT 15 GREASE HOOD DETAIL 1 OF? 2 HOUR SYSTEM ELE00 ICAL (UNDER PYROSCAT) CONDUIT (UNDER PYROSCAT) LICN7 (,UNDER PYR SCAT) NOTES: 1. ALL JOINTS TO BE INSTALLED W1114 A 3° OVERLAP AND ANCHOREf2 IN PLACE WITH INSULA"ION PINS AND SPEED CUPS WHERE REQUIRED. P.01 PAGE 03 LEGEND R/ T .• A P5 Or ROSG►T• PP Uu T P W = AN+1N1C,. 3 PERIMETER OVERLAP H " SEAM OVERLAP TOTAL P.01 110,61 ag I PERMIT CENTER UP -BLAST EXHAUST FAN ROOF STRUCURE FIRE -WRAP INSULATION GREASE DUCT MAKE -UP AIR DUCT TO HOOD THERMAL INSULATION INSULATION ACOUSTIC CEILING TILE MAKE -UP SUPPLY PLENUM GREASE HOOD SECTION p4T GREASE HOOD A4I1 1/4' = 1' -0' i 201 Main St SE Suits 325 5541"11 T 612- 379 -3400 F6 12-379-4400 (uringhem troop RAINFOREST CAFE SOUTHCENTER MALL TUKIIILA, WA Data 4/30/99 Comm. No 97175 Revisions 0 05//99 , L 0 0 v .� �s o ur� U ❑ CO CO N LL/ w 5 Drawn by a1K City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director Paul Ragozzino Cunningham Group 201 Main Street SE Minneapolis, MN 55414 Dear Mr. Ragozzino: RE: CORRECTION LETTER #1 Development Permit Application Number M99 -0081 Rainforest Cafe 290 Southcenter Mall This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Division. At this time, the Fire Department, Planning Division and Public Works Department have no comments regarding your application for permit. The City requires that two (2) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation, please submit two (2) copies of each document. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206)431 -3672. Sincerely, 'kccu& gai— Brenda Holt Permit Coordinator encl xc: File No. M99 -0081 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 TUKWILA BUILDING DIVISION Plan Review Comments DATE: May 11, 1999 PROJECT: Rainforest Cafe PLAN CHECK: M99 -0081 Plan Examiner: Bob Benedicto 1. The revision submittal of 4/29/99 does not include the cross section of the Type I hood and duct which shows its penetration through the roof structure. This request for additional information remains incomplete. Please note that the method for providing the required fire resistive protection of the grease duct needs to be detailed or otherwise specified. A construction specification of the hood or other means of describing its construction is necessary to document code compliance. The required fire resistive enclosure of the grease duct which serves a Type I hood is stated in UMC Section 507.6. In addition UMC Section 508.4.1 states: " Type I hoods or portions thereof penetrating a ceiling, wall or furred space shall comply with all the requirements of Section 507.6 ". Clearly this means that the hood or any portion thereof must be protected, as is the grease duct that serves the hood. If this is the case, the additional information must include the method of providing the required fire resistive protection of the hood and the proposed method of securing said required fire protection material to the hood. TRANSMITTAL SHEET To .744, W Date 07?' Attention IV .5/2 P18 -1 o;vA2/*‘i°1.f2, Re . "`/ Our Job No. �. � % - /4 /.��.'""'��. /,P'� " 4N L,- -ZOB/ Transmittal No. 0 Sho Drawing Su bfii ttals O Re ubmittal s Spec. Section Gentlemen: We are eturning (under separate cover) the following documents which are: ❑ Reviewed ❑ Reviewed as Noted ❑ Revise and Resubmit For Your Approval o For Your Records ❑ For Your Information ❑ Preliminary ❑ Revised ❑ As Built NO. OF COPIES SEPIAS PRINTS XEROX COPIES 4 DESCRIPTION 4, ✓t% /( r7 2 tip%• L 7€;? `f.Y''Y,z J/ RECEIVED CITY OF TUKWILA APR 2 9 1999 rERMIT CENTEP. o . Remarks Per CGS (6702) 7a '5/ City of Tukwila John W Rants, Mayor April 27, 1999 Department of Community Development Steve Lancaster, Director Paul Ragozzino Cunningham Group 201 Main Street SE Minneapolis, MN 55414 RE: Letter of Incomplete Application Development Permit Application Number M99 -0081 Rainforest Cafe 290 Southcenter Mall Dear Mr. Ragozzino: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 15, 1999 is determined to be incomplete. Before your permit application can begin the plan review process the following items need to be addressed. Building Division: Ken Nelsen, Plans Examiner, at (206)431 -3677, if you have any questions regarding the following: I . Cross - section must include hood duct and its penetration through roof, also show shaft. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation, please submit four (4) copies of each document. In order to better expedite your resubmittal a `Revision Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206)431 -3672. Sincerely, u44,L. Brenda Holt Permit Coordinator encl File: Permit File No, M99 -0081 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 C . Poryy,t-A- ex5-0-cd. PLAN REVIEW /ROUTIN SLIP ACTIVITY NUMBER: M99 -0081 DATE: .5 -14 -99 PROJECT NAME: RAINFOREST CAFE Original Plan Submittal XX Response to. Correction Letter # Response to Incomplete Letter Revision # After. Permit Is Issued DEPARTMENTS: Build ng Division frai L Public Works Fire Prevention Structural 11(lL. n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete lam) Comments: Incomplete DUE DATE: 5 -18 -99 Not Applicable n TUES /THURS ROUTING: Please Route No further Review Required n Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions DUE DATE: 6 -15 -99 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: \PR•ROUTE.DOC 6/98 ja COAL CO PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M99 -0081 PROJECT NAME: RAINFOREST. CAFE Original Plan Submittal Response to Correction Letter # DATE:. 4 -29 -99 XXResponse to Incomplete Letter Revision # _ After Permit Is Issued DEPARTMENTS: Building Division Veto de./tit,icd� Public Works fit A/0 Fire Prevention A (NC 5-7 -'1G/ Structuralw, Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete g4 Incomplete n DUE DATE: 5 -4 -99 Not Applicable Comments: TUES /THURS ROUTING: Please Route 2 No further Review Required Ti Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions o_CWL C -&c,o� i11/ 41 / kettle d -- 12-- '11 REVIEWER'S INITIALS: DUE DATE: 6 -1 -99 Not Approved (attach comments) DATE: CORRECTION DETERMINATION: Approved n Approved with Conditions DUE DATE: Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: \PR•ROUTE.DOC 6/98 Peyrrt T COOrci • CapJ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M99 -0081 DATE: 4 -15 -99 PROJECT NAME: RAINFOREST CAFE XX Original Plan Submittal Response to Incomplete Letter. Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: B &4Lee( ldingU1Di ision ZO1/ Public Works Fi Preve tion Ae C.421-'j Structural Planning Divisio Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete Comments:] �n pp Gil Ci Incomplete DUE DATE: 4 -20 -99 Not Applicable e !AY maid 4-sq-m TUES /THURS ROUTING: Please Route Routed by Staff No further Review Required (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions DUE DATE: 5 -18 -99 Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved Approved with Conditionsn Not Approved (attach comments) n REVIEWERS INITIALS: DATE: \PR-ROUTE.DOC 6/98 4)13)?? Date: CITY OF TUKWILA Department of Community Development Permit Center 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Response to Incomplete Letter is Response to Correction Letter ❑ Revision after Permit Issued Plan Check/Permit Number: M qq- b I Project Name: ROA ilf1DPe 6144 Project Address: Contact Person: Phone Number: Summary of Revision: A1717C7 A 171<tsIMIN6 VA Ll l 1 �✓%iGTl of J AT ,'Vp . t-kx I> FO lz GVf,1Zt P1GPc --no / ,u Res p o "us 94) / n, e ivt /e. 22,7 /c" i 6/R 199 1/ 14 Crop ies l iuscfict ll,a �iow 1lus5r'Hc«`�io.�S 'T et9ecF5 ne..4;1 k 74 ,g�owl�c. S'�� t ��tera_ /rccc 1 co, y 051 m A cu u cr xt c vc., Re �e s p 2C s �� //U S u: �9 Silo; py #.-c) SCA `I r%). / RECEIVED CITY OF TUKWILA Sheet Number(s) "Cloud" or highlight all areas of revisions and date revisions. Submitted to City of Tukwila Permit Center /611/C-#4.- Entered in Sierra on 6 -14-9q M PERMIT CENTER 3/4/99 CITY OF TUKWILA Department of Community Development Permit Center 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Date: 14:291 -41C21 R Response to Incomplete Letter ❑ Response to Correction Letter Revision after Permit Issued Project Name: Project Address: Contact Person: Plan Check/Permit Number: " t 1-oos 1 fe_itext-ICeet/if! Summary of Revision: Phone Number: 6 (-1-705 `7 93 Pece9g4e Lp‘. 411/- blefriVc-17 VAVY7 RECEIVED APR 9 q 1999 PERMIT CENTER Sheet Number(s) l WI " 7 Y©/ � saO� i ria �cia- "Cloud" or highlight all areas of revisions and date revisions. • Submitted to City of Tukwila Permit Center Er Entered in Sierra on '2a. 3/4/99 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire chief April 27, 1999 Fire Department Review Control #M99 -0081 (510) Re: Rainforest Cafe - 290 Southcenter Mall Dear Sir: The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. An approved automatic fire - extinguishing system is required for this project. All new automatic fire- extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. Commercial -type food heat - processing equipment from which grease -laden vapors emanate in normal cooking application shall be protected by an approved automatic extinguishing system. The extinguisher system shall be interconnected to the fuel and current supply so that the fuel or current is automatically shut off to all equipment under the hood, when the system is actuated. (UFC 1006) 2. A wet chemical portable fire extinguisher having a minimum rating of 2A:1B:C:K shall be installed within 30 feet of commerical food heat - processing equipment, as measured along an unobstructed path of travel. 3. Local U.L. central station supervision is required. (City Ordinance #1742) 4. Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575'.4404 • Fax (206) 5754439 City of Tukwila John W. Rants, Mayor Fire Department- Page number Thomas P. Keefe, Fire Chief 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110-16(a), NEC 110-16(c)) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, 5/0 The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Plane: (206) 57$ 4404 • Fax. (206) 575-4439 0. •• ••••• •.! • t.; ' • : : ..•;• •••••, 7.; . . .. • " .1:4:%i::, 4 .' ':".P::t; '4-• REGISTERED AS PROVIDED BY LAW ASie,:.:!,. CONST CONT GENERAL i.i.•:ii:•:,...::,::•::: •• ...: REGIST . # • EX'. DATE CCO1 PCLCOSI099NW 06/01/1999 I EFFECTIVE DATE 08/16/1991 1 i -P C L. CONSTRUCTION .SRVC INC PO BOX 52868 i BELLEVUE WA 98015-2868 i Sign= Issued by DEPARTMENT OF LABOR AND INDUSTRIES ! • . . . ,;•.'; ;-.„;:. t ..::.•• to. I. :. . • :.• ; • '••:..' ' • 1•:•; .•;, • -.:•••,.•••:::'1•,,""i 1,•:-.,..;:••4.• • :.• ".•• i.•:• • ,:!::7•1t• '+•tt,-- • :••• • '"'"' " • ' '1, • •.:;::; 1 , • •• Ir ..1l • • . t. • . • U V ) re A rlT1 A I I /IT!'I Ir I I\ /An rNl AA GENERAL NOTES 1, COORDINATE LOCATIONS OF CEILING DIFFUSER, RETURN AND EXHAUST GRILLE LOCATIONS WTTI4 LIGHT FIXTURES. 2. FLEXIBLE DUCTWORK IS NOT ACCEPTABLE. 3. COORDINATE AU. DUCT HEIGHTS WITH LIGHT FIXTURES, FIRE SPRINKLER PIPING AND OTHER TRADES. NORTH l 'pLVh -1) KEY NOTE O 16/20 GREASE DUCT UP. TRANSITION TO FAN INLET SIZE AT ROOF DECO N CONNECT INTO EF -1. REFER TO DRAWING M300. O 22/20 GREASE DUCT UP. TRANSITION TO FAN INLET SIZE AT ROOF DECK & CONNECT INTO EF -1. REFER TO DRAWING M300. O BALANCE TO 6500 CFM. 18/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS 4 PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO F ' I C - I S v . 9 N 11 20/12 MAKE -UP AIR DUCT CONNECTION TO HOOD, VERIFY COLLAR 5 LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1700 CFM. 27/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS O B PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 3000 GEM. 25/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS O PANEL AT CONNECTION TO HOOD, VERIFY LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 2800 CFM. O 28/12 MAKE -UP AIR DUCT CONNECTION TO HOOD, VERIFY COLLAR LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 1320 CFM. O 25/10 GREASE DUCT CONNECTION TO HOOD. PROVIDE ACCESS PANEL AT CONNECTION TO HOOD. VERIFY LOCATION PRIOR TO F NI A 0 OF D C 0•K B•L NC T. 2 CFM. • e S'M • F • • •IY• SI 6/4 DUCT CON PRIOR TO FABRICATION. BALANCE TO 200 CFM. 11 16/4 DUCT CONNECTION TO DISHMACHINE, VERIFY COLLAR SIZE PRIOR TO FABRICATION. BALANCE TO 400 CFM. FULL SIZE SUPPLY AIR DUCT UP TO IT-I. VERIFY TRANSFER FAN Ax DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWORK. Q F S1ZE TURN AIR DUCT OP TO TF . VERI TRANSFE DUCT ULL CONNECTION SIZE AND LOCATION P TO FY FABRICATIR ON FAN OF DUCTWORK. t4 CONTROL PANEL FOR JOB. TF -1, EF -1 AND EF -2. COORDINATE EXACT LOCATION 15 ACCESS PANEL. 16 LOCATE GREASE DUCT IN CEILING SPACE TO PERMIT EASY ACCESS TO GREASE DUCT ACCESS PANELS. Se I Ax 25/10 GREASE DUCT UP. TRANSITION TO FAN INLET SIZE AT ROOF DECK & 18 CONNECT TO EF -9 ON ROOF. REFER TO DRAWING M300. 10 28/12 MAKE -UP AIR DUCT CONNECTION TO HOOD, VERIFY COLLAR LOCATION PRIOR TO FABRICATION OF DUCTWORK. BALANCE TO 2280 CFM. • TO TO RTU -4 ON ROOF. 21 BALANCE TO 0725 CFM. ® FULL SIZE SUPPLY AIR DUCT UP TO RTU-4. VERIFY RTU DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWO ® FULL SIZE RETURN AIR DUCT UP TO RN MU -4. VERIFY U DUCT CONNECTION SIZE AND LOCATION PRIOR TO FABRICATION OF DUCTWO GREASE DUCT TROUGH WITH 3/4 DRAIN VALVE, HOSE CONNECTION AND WATER /GREASE TIGHT CAP. REFER TO DETAIL 2/8512 FOR INSTALLATION REQUIREMENTS. r • 18/16 EXHAUST AIR DUCT UP TO EF -3 ON ROOF. ® ROOF OPENING AND CURB DT MECHANICAL CONTRACTOR. ® REFRIGERANT PIPING IS FURNISHED AND INSTALLED BY DEI. PIP ROUTING SHOWN IS FOR INFORMATION AND COORDINATION ONL nnnnnn EXACT LOCATION AND ROUTING SHALL BE COORDINATED BY PC AND 110. PIPING SHALL BE INSTALLED PRIOR TO WALL CLOSUR ® DISHWASH EXHAUST DUCTWORK. REFER TO SPECIFICATIONS. EXPOSED DUCTWORK SHALL BE STAINLESS STEEL, CONCEALED DUCTWORK SHALL BE ALUMINUM OR STAINLESS STEEL WITH ALL JOINTS SEALED WATER TIGHT. PITCH DUCTWORK A MINIMUM OF 1/4" PER F00T TQWARD 1'1 .. Q REFRIGERANT PIPING T0 EACH4COdI.ER)IFREEZEII BY DEI. ® REFRIGERANT PIPING LIP TO REEKIGE UNIT ON ROOF BY DEL SEE DRAWING 8300 FOR CONTINUATION. O COMBINATION SMOKE /FIRE DAMPER. © FULL SIZE EXHAUST AIR DUCT UP TO EF -8, EXHAUST DUCT TO BE SAME SIZE AS EXHAUST FAN DAMPER. ® REFER TO DRAWING M200 FOR CONTINUATION. SEE 1 /8210 FOR CONTINUATION VIED E- 125 -8 /8 12 L ICUOR STORAGEO 12'0 LL A OvN MAINTENA ROOM C7 J /6 i. im i ■ LIMN 11 III 3 0-125-10/0 I I - MEM Ebb IRENE I 20 8 -150 CORRIDOR H _ 121 W MEN5 I� _ REST RCOM e -- n A rrri A I Il1rr'LI r- M I LJ\ / A DI AA! RK. RK. ;•nRAM PERM tI_rn FOR NANICAL . TflICAL N LUMBING 13 GUS PIPING 0 cTP 1I103MILA . 1I" O MASON Date: FILE COP‘i I1t,0l the Plat` Cctecl10 U. NA Dole: Reg. HA Sheet T e 615 <In -teal nl nI On< wleelUC KITCHEN HVAC PLAN j Architecture W �in &0U2 Interior Design Plonning Construction Services 201 Main St. S.E. Suite 325 Minneapolis, MN 55414 Telephone: 612 - 379 -3400 Facsimile 612- 379 -4400 Internet: www.cuningham.com 12/21/08 PROPOSAL RBQUBST I. 1/20/00 PEOPOBAL REQUEST /8 12/22/08 PFOIeet The RAINFOREST CAFE Southcenter Mall Tukwila, WA :101.5 anp p CF.IVEG nITV OF TUNWILA APR 2 9 1999 •FRMiT CENTEP 7/2/88 CAPIID 2MB \DTR 292 -01 OPOS,AL REQUEST 4 mqq- nos I AY 1 9 1999 __- M2 1 0 FIRE PROTEC SPRINKLER SYSTEM O E$IGN, • OC ADSIFI HAZARD CLASSIFICATION S YYTEM DENSITY . TYPE GPM /SQFT REMOTE AREA S O • M %. ARE HcAE OEMANe SQ.FT GP O ok A MR. 'FC' SPOILER TYP SPRINI(I,eR HEAD . 'FIN SH ;` 4 ME '9 TIi f M •�'[4 CE • O ' " ! IpFFlcr ' ORDINARY N ET 02 0 NET 0.A J000 0000 170 " �1 ISO f 'S P O l ' „ :y ' . AREAS ABOVE CEILING ORDINARY AflflFAE'INI O�iEEN¢RY CE0.14''• gQq1U�II1 I , 99WP 2 NE T 0. 20 .. 000 30 230 1 '• 1 a ' aSPG, •:• 4 KITCHEN HOOD WITH PRE -PIPED FIRE PROTECTION SYSTEM. , .. EMI=COT EE LUl1NTIhICI 1. MEN Ilc I I I OQ, (II MUSHROOM DAR • 161/ 1 L RFufLilu..Il SFICIrI FUC'I': I ! :i II,gi WAK-IN "• L r h COOLER I WALK -IN COOLER 't rng - ORDINARY KEY NOTES O INSTALL SPRINKLER HEADS IN MUSHROOM CEILING AND ABOVE MUSHROOM AT HIGHER CEILING. REFER TO ARCHITECTURAL REFLEC COONS FOR LOCATION OF SPRINKLER HEADS IN MUSHROOM. , O INSTALL SPRINKLER HEADS AROUND THE PERIMETER UPTRE,RCULUS INS ORDER TO PROTECT BELOW. AOD CONCEALED HEADS IN THE OCULUS AS NECESSARY TO. PROVIDE ADEQUATE SPRINKLER COVERAGE PER NFPA TO SPRINKLER HEAD LAYOUT IS TO MINIMIZE;'{HE NUMBER,,OF HEADS <, • REQUIRED IN THE LCULUS, SUBMIT OCULUS ; HEAD LAYOUT TO ARCHITECT PRIOR TO HYORAUUC DESIGN AND SUBMITTAL' TO, THE ENGINEER, SPRINKLER HEADS MAY BE REQUIRED IN EACES9 OF CODE AS DETERMINED OS RE`•IEW BY THE' ARCHITECT ,HEADS ARE'NAT TO RE ENTERED IN THE OCULUS. O J INSTALL SPRINKLER HEADS ALONG THE AQUARIUM ARCHWAY,M,OROER TO PROVIDE COVERAGE BELOW THE ARCHWAY PER NFPA0hr GREENERY CEIUNG AREAS. REFLECTED CEILING PLANS FOR HEIGHTS. SPECIFICATON9. "REFER 70 ARCHITECTURAL S#ENERAL NOTES L COORDINATE SPRINKLER HEAD LOCATORS WITH ARCHITECTURAL EFFECTS HANGING FROM THE CEILING. SEE ARCHITECTURAL DRAWINGS FOR CEILING DETAILS. 2. THE CONTRACTOR IS RESPONSIBLE FOR REURWINO ARCHITECTURAL DRAWINGS AND COORDINATING SPRINKLER HEAD LOCATIONS WRY THE ARCHITECTURAL EFFECTS IN ORDER TO COMPLY WITH NFPA TS. 3; INSTALL DRY PENQENT HEADS IN ALL COOLERS FREEZERS• 4. ANY EXPOSED PIPE AND FITTINGS SHALL SE STAINLESS STEEL IN'KITCHEN AREAS. WET I 0.20 230 .. ■ Y. e1.0 :.`an.,e ratrr 'r Dale: Tukwila, WA Cuttghem Gray K llllectu10 nlerier 001ITn' Honing , • enTINGUMI'SeNcit '171 Maln SL S.E. 0011e 22S 'e. Inneapols, MN STIR elephone. 12- 379 -7400 Ti ocsim 612-379-14011 Internet' ww.nuninghem.cam 02/20/00 'ROPOBAL DENOOBT , T /E /00 Comm, He CAP1IS ART • 12/22/00 Reg. No DOS •O1 Pried /So RAINFOREST CAFE Southcen.ter Mall CrTY FCFI ,li<N J AAP . I ' M cx U 'FAA w • -- "� 1�c pIV`ISIotI CONSTRUCTION S J-• F i .'.lip sivem '''ROOFTOP AIR HANDLING UNIT SCHEDULE MANUFACTURER: AxE UNIT ®r RN -I '- • MFR. k MODEL NO. LOCATION ROOF AREA SERVED DINING a BAR CFM 6000 SUPPLY FAN DATA DX COOLING COIL DATA GAS FURNACE DATA UNIT m MCA hfi0 -3 -60 34 UNIT OPERATING N£ICHT 00TH ROOF CURB 1050 1850 REMARKS ESP 1.00 TSP OUTLET VELOCITY RPM FAN Bur 3.97 3.97 [AN HP 5 5 NO. ROWS J FINS/ INCH 15 FACE AREA 17.5 FACE VET. 343 APO - EAT .COIL LAT UNIT SENS. MAN 102.4 TOTAL, MBIi 1435 TOTAL TONS , 12.5 EA7 62 ..LAT 01 MOH _INPUT; 160 MBH _OUTPUT 122 DB 72,5 WB 024 624 DB 50.7 56.7 V.83 54.2' FINE Y0015.413 - - 928 TNO STAGE GAS HEAT. 0 - 25 0 MANUAL OUTSIDE AIR DAMPER. 1000 CFM. . 11111‘,2 . '4111 - 2 THANE YC 151C .fl ROOF DINING 6000 1.00 - - 926 J 15 17.5 343 - 72.5 54.2 1024 143.5 12,5 62 81 150 122 34 TWO STAGE GAS HEM. 0 - 25 K MANUAL OUTSIDE MR DAMPER, MOO CFM. 010 - Y00I21C4LB ROOF RETAIL 5000 1K0 - - 851 2.x4 5 3 15 17.5 285 - 74,2 02.6 56.0 54.5 97.9 121.0 10 61 83 150 122 31 1850 1WO STAGE GAS HEAT. 0 - 25 X MANUAL OU15DE AIR DAMPER, 900 CF1.1. RN -4 MANE S60MLA ROOF KITGIEN, STOH, E MAIM. OFFIC 12225 1.00 - - ____ - 615 6.76 0.55 097 10.0 0.75 I 0 14 31.67 306 - 79,2 61,4 53.5 63.2 63.7 62.0 60 60,6 55.5 245.4 353.8 30 80 • 88.9 , 350 00 : 283.5 7J 81.23 11.8 4500 950 1060 STAGE GAS HEAL, 0 - 25 R MANUAL OUTSIDE AIR DAMPER. 2500 CFM. IN0.UDf FULI. OOCFM O.A. MINIMUM ECONOMIZ ER AND BAROMETRIC RELIEF RN ^6 . MANE 4OC 49G YC ROOF OFFICES, BURN R EMPL _ iGI 1ET5 FR R0044 1660 0.70 _ 0.80 - 850 __ 1002 J 3 IS 120 273 N" 77.2 55.6 50.6 53.7 30.7 47.5 651 i 58.2 909 RN -8 MANE T000740400 ROOF 2485 - I5 6.33 206 - 75.7 76 0 74.9 05 _ _ 54.2 57.2 0 - - - - 17.8 050 INCLUDE- FULL ECONOMIZER AND BAROMETRIC RELIEF (200 CFM O.A. MINIMUM) - • R1117, MANE TC0R49 OO RF ET. A H PUMP ROOMS SHOW 1690 0.66 - 850 OM 0.75 1 J J i 15 7.9 275 - 5fi.7 54.8 A1.] 50.2 4 - - - N.6 000 INCLUDE N ECCNCMI ) ER AND BAROMETRIC RELIEF (500 CFM O .A. MINIMUM) RN -0 THAN E E TC00740400 ROCK ELECTRICAL ROOM 2400 0 .60 - _ 969 0.02 -- 1f2 75 7.9 --- 10.0 275 - -- 0.55 55.4 6J.fl 931 61 00 4 64.8 6 - - - - -- 178 050 INCLUDE FULL ECONOIZER AND BAROMETRIC RELIEF (200 CFM O.A. MINIMUM) MAUF GRA ROOF DINNINCJIAR R PL1AIL MAKE W AIR 8000 1050 0 1.00 _____' 0.60 _ - 715 3 10 553 I31 -- 142 10 2 6 2 400 320 5.25 2100 SET SUPPLY AIR PAMPERS FOR 2500 CDJ iO RIV -1, 2500 CFM i0 RTV - 2 ANa 1ODO CRU TO PRI -J. OF -1 MANE ANOAIOOGFODO ROOF 6I1CH0011OID MAKE UP AIR ___ - 705 567 >.5 .. _ - - _ _ _ - 1625 FURNISH MOTORZE WU E AI AN E R OOF AIR DMPERS. SET O.A. DAMP ER FOR 4000 CFM. PROVIDE TSI I I 14" R RICH R OOF CURB . PLUMBING FIXTURE SCHEDULE nXTURE N0. FIXTURE TYPE --- WASTE _._ VENT -_.1.____ IN" -- HW __._ REMARKS REMARKS WA1E CLOSET _ _ - -___ _..__.. _. _ ID URINAL I / KO URINAL W ATER CLOSET - IIANDICAP 4' 2" 1N" 0 SUPPLY DIFFUSER STEEL 2' 114 24 " LAY -IN L ACE DFN501 SEE PLANS FAL FOFR NECH I SIZE 01 - HANDICAP 2' IN' I" - - 1(0 COUNTER LAVATORY UV IN" - N" TEMPERED SUPPLY ID COUNTER KO WALI. LAVATORY - HANDICAP 111" IN" - N" TEMPERED SUPPLY HUNG LAVATORY - HANDICAP IN" IN" - N" TEMPERED SUPPLY 0 1101 USED - - - - - ID NOT USED - - - - _ 08111 OPPOSED BLADE OAMPER SIIOWEN 2- 1.. N" N' (2) HEADS, MOUNT CONTROL VALVE. COMM OF STALL �w (1'11 S.S. DOUBLE SINE 2 111 N" N' - !!! 111 333 NOT USED ,- - - - - ® CON WASH 3' IN" F," TARA SEE PLANS NARI OPPOSED BLADE DAMPER MOP SINK 3" 111' 35 TMSA 24 "x21 " /12'x12" FACE ® INTERIOR HOSE 61118 - - N" - - CO IRO ir 17 PRIMER - - K - - FLUSHING FLOOR SINK vALYE - - I" - - INSTALL IN LAY -IN CEILING 6050)0x11 ,700011 - - Al" 1; - I. 9 DIERMOSTAIIC 91161119 VALVE - - N" AM1" I" OUTLET _ THERMOSTATIC MIXING vAL1E - - N" N" F," OUTLET 'I'GR LLE, ;REGISTER & DIFFUSER SCHEDULE MANUFACTURER: AlPD METAL TYPE . FUNCTION CONSTRUCTION TYPE MAX. N.C. MODEL NO. NOMINAL SIZE REMARKS A SUPPLY DIFFUSER STEEL 35 11ARA SEE PLAITS WITH OPPOSED BLADE DAMPER 0 SUPPLY DIFFUSER STEEL 35 TMSA 24 " LAY -IN L ACE DFN501 SEE PLANS FAL FOFR NECH I SIZE 01 SUPPLY OKFUSER STEEL 35 TMSA 24 "x24' /I2"xl2" FACE SURFACE MOUNTED W D SEE PLANS FIN4 NECK SI NU FACE SITE C SUPPLY REGISTER ALUMINIUM 10 RIO/ (SE.IHO) 6 48114 OPPOSED BLADE DAMPER 0 SUPPLY REGISTER ALUMINUM 35 300 FL SEE PLANS V4111 OPPOSED BLADE DAMPER . E RETURN/EX AAOUSST/TRANSFER ALUMINUM 35 350 Fl. SEE PIANS - F . RETURN/EXHAUST /TRANSFER GRLLLE ALUMINUM 30 50 FF SEE PLANS fgAMF. TYPE 1 LAT -IN, I/2'XI /2'x1" BRIO 0 RETURN/EXHAUST REGISTER ALUMINUM 30 350 F. SEE PLANS 08111 OPPOSED BLADE OAMPER N SLOT DIFFUSER ALUMINUM 30 M -35 SEE DINNN - 1 CONCENTRIC DIFFUSER ALUMINUM 30 1013 -0300 SEE PLANS - J SUPPLY DIFFUSER ALUMINUM 35 TMSA 24'X24' LAY -IN FULL FACE 01E1,5E0 SEE PLAITS FOR NECK SISE K SUPPLY DIFFUSER ALUMINUM 30 TARA SEE PLANS NARI OPPOSED BLADE DAMPER L SUPPLY DIFFUSER ALUMINUM 35 TMSA 24 "x21 " /12'x12" FACE SURFACE MOUNTED W AMPER. SEE PLANS FOII NECH 512 AND FACE SITE M SUPPLY DIFFUSER ALUMINUM 35 PM) 24'x24' LAY -IN PERFORATED SUPPLY GRILLE MISC. EQUIPMENT SCHEDULE MANUFACTURER: - UNIT N0. MFR. Ac MODEL N0. LOCATION AREA SERVED FAN DATA CAPACITY MOTOR DATA REMARKS CFM SP BTU AM. AIR KW BHP HP RPM V -H -Hz SF_I FlSQ- 180 -7 - GREENHECK RJ 108 HABITAT ROOM H 106 ABITAT ROW S000 IMO 0.75 OS p - - 0.74 _ 1.0 961 1 480 -3 -60 ' .' - SF -1 qR EN E C 050 100 R T AL C IRO O P I I • 0 CU "' - 1TA- 12004000 ROOF OININO, OAR k RETAIL - - f00 R5' F - - M A 12.0 1100 480 -3 -00 NTH HOT OAS BYPASS FIIC -I !NUM WA HABITAT ROOM 106 HABITAT ROOM 3000 - 51105 - 15.0 - - - 400 - 00 3 STAGE El IC -2 INDEECO RETAIL S STORAGE 4 RETAIL OFFICE 105 105 - 3413 - 1.0 - - - 208 -I -60 2 -STAGE FU11 -1 IIUIIAA - -I OERKD O4P MECHANICAL ROOM 117 MECHANICAL ROOM 117 550 - 34130 - 10.0 - I /JO 1600 460 -3-60 - 'I.' DERKO R "C11 -AE -648 CORRIDOR 118 CORRIDOR 285 - 6820 _ 20 - - - 208 -3 -60 INSTALL IN LAY -IN CEILING Eul l - J B 070117E CORRIDOR 127 C00R100R 127 285 - 6826 - 2.0 - - - 201 -3 -60 INSTALL IN LAY -IN CEILING IDE-I T,IERNLIIND LI ROOM I1II ROOM 17 ROOM MECHANICAL M) _ _ _ - - 0.25 1726 f20 -1 -00 _ UHF -,2 TJERNLUND MECHANICAL ROOM 117 MECHANICAL ROOM ill - 0.25 1725 120 -1 -60 - EXHAUST FAN SCHEDULE MAN, AD7LIOFR'00106110tH UNIT NO. D 1 LIOOEL NO. am 70 P LOCATION 001 AREA SERVED u1 0011 FAN DA IA MOTOR DATA REMARKS I1 761 A. NSF LI 11 WsiFfL TYPE .. CfM ESP TSP .. ItPM11 IMP 11!' 1 .1 v -n -Ilx X T.- 75 - - - �A 242 GA')) AT 60' F TEMP. RIS - ONM-2 - 070,200 MECHANICAL ROOM 109 76 - 120 -1 -60 242 GP 1 Al 60' F TEMP. R ISE 94)1 CUM 1 O P11/11.10 111.511100m$ uvu 800 - 0 50 Ions 0 109 n 15 170 -1 -00 111111 ROOF cu011 Lr_I 00-1 5 130 CP11 Al 140 F TEMP. RISE ROOF FIL111,1011 MO NO. CMPIOVIt n n. 120-1-50 111f ROOF CIIRU - OR- C20- 7-414 ROOF 11A011,1 1100IA AI son 1375 0 0 50 010-3 110 R001 C.11 SWAT NOW AN11 Nw x L 15]1 110 a ZU x411 -.l -u0 Fr -a ,.UU - ■41 ROOF It, 1,UUn Aluu. 2500 - 1 5 :WATER HEATER SCHEDULE MANUFACWEN: RIIEEM ' 1 . ', UNIT . • D. ■ . 1 MODEL NO. LOCATION - GAS INPUT MDII - STORAGE CAPACITY, GALLONS EI.ECTNICAL - - - -- HP UA IA REMARKS V -e -H DNP ® 11111 III. 070-200 � MECHANICAL ROOM 100 X T.- 75 - - - 120 -1 -60 242 GA')) AT 60' F TEMP. RIS - ONM-2 - 070,200 MECHANICAL ROOM 109 76 - 120 -1 -60 242 GP 1 Al 60' F TEMP. R ISE 94)1 076 -200 MECHANICAL ROOM 100 75 .. 120-1-60 134 GP11 At 140' F IELIP. OI Y Q 1 41T {. 0N -200 MECHANICAL ROOM 149 74 - 120 -1 -60 130 CP11 Al 140 F TEMP. RISE PUMP SCHEDULE MANUFACTURER' figu,LQQ Sg5 ,T 1INIT NO. - ----A� MFR. 20 MODEL NO. -- BAG SERIES 00 LOCATION 0.__ MECHANICAL ROpA1 117 AREA SERVER ISO• HAIR FLOW DATA MOTOR DATA REMARKS GPM 5 HD __ _. iiHF 10 26 DNP ® 11111 III. 1 _® / 1/4 ,} ; 411 H2 . ' 115+1 - 00. 1 ' CP -1 - GP-2 080 SERIES 60 MECHANICA117 L OW 720'11010 10 115 1 -SO( - 4200 SOIAAT ROOM 350 TENANT SPACE AIR BALANCE TENANT MAKE UP AIR CFM TENANT EXHAUST AIR CFM ROOFTOP AND MANE UP AIR UNITS 16700 HABITAT ROOM 3500 (KITCHEN 15250 5UD TOTAL ROOFTOP AND AND MAKE UP AIR UNITS 16700 TOILETS 1000 FILTRATION M JANITOR'S ROOMS BOO MAKE UP AIR FROM MALL COMMON AREA 4200 SOIAAT ROOM 350 TOTAL MAKE. UP AIR 20900 TOTAL EXHAUST AIR 20900 I. CORING CAPACITIES ARE BASED ON 85' F AMBIENT NR TEMPERATURE. 2, UNITS SHALL HAVE SINGLE POINT POWER CONNECIICN. J. PROVIDE MINIMUM 14' HIGH ROOF CURBS FOR UNITS R111 -5 RIHU 4111 -8. 4, RN -1 RIRU 41U -4, MAO -1 AND IF -1 SHALL RE SUPPORTED ON RAIL SUPPORTS FURNLSHE0 AND INSTALLED BY GENERAL CONTRACTOR, REFER TO STRUCTURAL DRAWINGS. MECHANICAL CONTRACTOR SHALL PROVIDE ALL ROOF OPENINGS'41111 CURBS FOR DUCT PENETRATIONS, FLASHING! ANO UNIT RE 00NNS. 5.'AECTPoC SERVICE SHALL BE PROVIDED THROUGH ROOF CURB. E) UNIT NO. E£ -2 EF -J gF -4' EF -e EF -0 C EXHAUST FAN SCHEDULE SHEET M500 1 TUTS ON -200 o I 5101.0 MECHANICAL R0064 109 76 FLOOR ' SINK � FLASHING FLOOR 1614 "016 FLOOR DRAIN & AREA DRAIN , SCHE FLOOR DRAIN NO. AREA DRAIN NO. MODEL N0. SERIES 49050 44850 SERIES 49120 SERIES 30000 SERIES 30000 -A SERIES 30000 -E2 SERIES 78010 R BRAIN 004 DRAIN 46111 NNNE ANUFACTURER: ;REMARKS COVER ORA NN: 34TH HALF COVER ORATE (STARE GO VLR HEIGHT OOR DRAIN 14171, TRAP PRIMER CONNECTIONS ?R)11-- See'nisi(∎( OI. Ct Milci-oog I LINT ) I 1'T`19 Oa.n: Dgned: Doty Rog. No. Sleet TM 914111 Narks. 111019 PF6*eD1 Tb RAINFOREST CAFE MECHANICAL SCHEDULES Architecture S Q Interior Design Planning Conslraction SnviCes 201 Main SI. 5.E. 50114 325 MhneapMls, MN 55414 Telephone 612-379-3400 Focslm1 012- 379 .1400 Internet: M500 www Cuninghom 10m R6 Mons Nu. Ode Ponta* IS/20/50 PROPOSAL 105068E ft. {,f, 061a 7/2/04' Comm No. CAP( 10 Southcenter Mall Tukwila, WA REGE VCD CITY nF rJKw . 22 /22/08.,; CONSTRUCTION SET rcco1 nY -PASS GAI.M — HIFI OPEN FlIll. PORI TAIL VA OTT') SCALE 00101. SEE SPECIFICATION SECTIONS 15140 AND 15205 FOR ADDITIONAL REQUIREMENTS HANGER ROD LOCKING NUT SIIPPOAT NUT ADJUSTABLE C1ENS HANGER CUT INSULATION AT HANGER STRAPS PIPE INSULATON - EXTEND FULL SI2E THRU HANGER WOOD OLOCK - SEC SPE.CIFICARONS METAL INSULATION — PROTECTION SHIELD (12" MINIMUM LENGTH) 0DMFSTIC N(1T SATE O CLEVIS HANGER DETAIL PINGS 9 EM5_DNLY I NO SCALE (INSULATE) PIPING) L CHECK VALVE 4" CONCRETE PAD Or MECHANICAL CONTRAC 1011 O 10 WATER HEATER DETAIL NO SCALE PLUG TO UNIT O GAS PRESSURE REGULATOR DETAIL NO SCALE 6-9'140 2N" OW T De uIN. Re" Cw ��H FW See T1)15KaO GTE)TOTED on) 0vO0S ;'6,P:ge I1 1 211" LINES CAPPED AT 7' -0" A.F.F. GH —IN FOR WATER SOFTENERS 210" Cw 3" GAS - -- I .) VALVE - - -�_ 6 - 2 - 2C 24" x 20" EXHAUST DUCT, SEE U200 BALANCING DAMPER, LOCATE IN DUCT NEAR SLOT DIFFUSER TYP OF 4 5' -0" LONG X 30" WOE X 12" DEEP . "I.,,� EXHAUST PLENUM, PRONDE FLANGE''.. AROUND PERIMETER TO SUPPORT TYPE F LAY -IN EXHAUST GRILLE. REFER TO ARCHITECTURAL DETAILS. H -250 -8 LOCRINS NUT (TYPICAL)'Ij 5 (TNP10 SEQTIQN5. 15140 AND 15200 Q OIREMTNTS ON .`DETAIL 2 -5 -6A PIPE`:. (TYPICAL)' 11 GOAL. IN5ULA115N PROTECTION SHIELD (12' MINIMUM LEN0T11) ONINSU(ATOU' PIPE NIGH DENSITY INSULA11R14 INSE117 ,. (HOT PIPING) WOODS:BLQCK (COLD PIPING) OR - SEE SPECIFIQAT( No RA NO SCALE REFER TO DET■I *P1' ON.MMALL'DRAWII'1G TTM-5 O CONDENSATE TRAP DETAIL NO SCALE 12 -3/ GAPANSIDN TANn8 tR 140,11(0 MRS OUT OP 08 01 '. .101 Man SI. S.E. ..Salle 325 • Minneapolis, MN , 55414 Telephone 1311-379-3400 facsimile 611-379-4400 in)ernel' www.cunn9ham.com 12/22/08 • J 0000091011200850 /L 7/2/98 CHAR, No CAP116, REFER TO DETAIL ' -#9 ON MALL DRAWING TTM 5 BIRD PER CH TRANSFER AIR A005 PIPE PENETRATION THRU ROOF SCALE (GAS AND PLUMBING VENT PIPING) STAINLESS STEEL COLLAR ADAPTER 310 TIP SS ONE SURGE HEAVER THAN DIE 'PS' STACK LINER. 'Pr TYPE FLUE HANGERS (TYP.) FILTER RACK WITH FILTERS 24"X24 , AIRFLOW , „ -�!—�— 2" MINIMUM OVERLAP 1 / CEA A RICH TEMPERATURE INTERIOR WALL SEALANT NT P PEN MANUFACTURERS .03S" f5 .039" THICK INSTALLATION INSTRUCTIONS TION9 n)ERM(OSTAQ MONO HA1;VE (PIS k 20) $41110 VALVE DETAIL iA LE MOUNT IN LINE DRAFT FAN IN STAINLESS STEEL COLLAR ADAPTER Q DRAFT INDUCER FLUE DETAIL NO SCALE FLEX CONNECTOR ROOT' E � DUCT • HEATER l TYPE '6' FLUE / TO HADITAS' ROOM GREENERY GEIUNO C> HABITAT ROOM SUPPLY AIR FAN DETAIL NO 80/4.E 6 ` m Groff WGhlleIlure ' Inlorlor Design Planning Co0SIIU<Ilon Sem< :,RAINFOREST `'CAFE ;,Sputhcenter Mall Tukwila, WA PGCEIVE r,li` QF TUKWa: 10/25/06', ..� 2" 120' SHW Y" 120' C11W EXPANSION TANK - AM TROT MODEL ST -12 -C, 4.7 GALLON RECIRCULATNG PUMP (CP -2) 01114 -2 120' CNW . —•»-,V awl SHWA EXPAN WOE TANN w 54. P „'�MpDEI, '40Y� QI1�12, DL T I OALLON RECJ(( CUL ATN4'�1U `. FLQW FIT5Np a i 110,MID M205:' FOR FLUES p 05' VW CONSTRUCTION SET 9i 'MECHANICAL DETAILS *NI !After M51 LINES FIR LI SEE PLAN - - FOR VIES SEEl • MAIN AIR REGULATOR • SEPARATOR • COALESCING FILTER - REFRIGERATED AIR DRYER CONCRETE PAD BR MECHANICAL CONTR. ISOLATION PADS O AIR COMPRESSOR PIPING DETAIL 1 NO SCALE OPTIONAL RISE BACKUP TO PREVIOUS INVERT ELEVATION WCW NQTES. 1. ANY CROSSING OF SHOW PIPING OR AQUARIUM PIPING SHALL BE ACCOMPLISHED BY OFFSETTING THE DISCHARGE LINES. ALL SUCTION LINES SHALL REMAIN FLAT AT A INVERT ELEVATION WHICH ALLOWS IRIS. 2. CONTRACTOR HAS THE OPTION OF GOING UNDER OR OVER THE UNE BEING CROSSED. 3. CONTRACTOR CAN HAVE THE OFFSET PIPE RETURN TO THE PREVIOUS INVERT ELEVATOR OR CAN RUN AT 111E NEW INVERT ELEVATION PROVIDING IT WORKS WITH THE OTHER LINES. v 21eLm (7 3 'rlern m 13 — S HOW PIPING OFFSET DETAIL NO SCALE 5 1>G � IxF :1' FLOOR SINK \ / SUCTION LINE SOMAT NQTES I. MECHANICAL CONTRACTOR SHALL INSTALL ALL VALVES PROVIDED WITH SOMAT UNIT AND MAKE PIPING CONNECTIONS TO EQUIPMENT AS REQUIRED. 2. PIPE SIZES TO BE IN ACCORDANCE Will DONUT RECOMMENDATIONS. 3 SLURRY AND RETURN WATER PIPINO TO BE TYPE L COPPER, SCHEDULE 40 GALVANIZED OIL EQUAL PVC PIPING NOT ACCEPTABLE). 4. SLURRY LINES MUST NOT INCLUDE ANY VALWNG EXCEPT THOSE AUTHORIZED BY SOMAT. 5. ALL FITTINGS MUST RE PRESSURE RATED DRAINAGE TYPE (SEE RIGHT) AND KEPT TO A MINIMUM. MAXIMUM ELBOWS ALLOWED 10 PER 100 FEET. USE ELBOWS ONLY TO CHANGE DIRECTION. DO NOT OFFSET AROUND BEAMS, COLUMNS, OR 0111ER OBSTRUCTIONS. 6, USE 45 DEGREE 0— BRANCH OR 20 DEGREE LONG TURN T —Y LINERS TWO LINES INTERCONNECT. CONNECTIONS SHOULD BE MADE FROM TIE TOP, 7. INSTALL ALL VALVES ANY CHECK VALVES HORIZONTALLY. CLEANOUIS REQUIRED IN SLURRY LINES ONLY AND MUST BE INSTALLED AT EVF,RY 90 DEGREE BEND AND EVERY 60 FEET MAXIMUM IN S1RAIGHT PIPE NUNS. USE 45 DEGREE Y—ORANCII AND 90 DEGREE LONG TURN T —Y FOR CLEANOUTS. (All CLEANOUTS MAST LIE ACCESSIBLE). D. SOMAT PULPER REQUIRE FLEXIBLE CONNECTORS IN SLURRY AND RETURN LINES ONLY. I0. COMPANION FLANGE, GASKETS AND HARDWARE NOT SUPPLIED AT PIPE LINE TER MINA BONS, II, KEEP ()RAINS ACCESSIBLE TO UNIT. DO NOT INSTALL DRAINS UNDER DONUT EQUIPMENT. 12. PIPING MUST BE SUPPORTED AND BRACED INDEPENDENTLY OF SQUAT EQUIPMENT. ALL INTERCONNECTING PIPING MUST BE SUPPORTED SO THAT NO MOVEMENT OCCURS DURING 01'ERATON. USE UNIONS OR FLANGES FOR FINAL CONNECTIONS. 13. NO EXTERNAL STRAIN TO BE EXERTED ON SOMAT EQUIPMENT. 14. IF 9i AIR LINE IS RUN UNDERGROUND, A LOOP SEAL EXTENDEING 3` ABOVE DIE HIGHEST POINT ON THE PULPER MUST HE PROVIDED. 15, AU. PIPING 10 BE IN ACCORDANCE WITH STATE AND LOCAL PLUMBING CODES. 16. I.) •• FURNISHED IYY SOMAT. I. AL 1. ALL ITEMS OATH AN ASTERISK N ARE PROVIDED BY K% INTERNATIONAL HANIL CONTRACTOR. AND INSTALLED qY MECHANICAL CONTRACC TOR. 2, PIPE ALL DRAIN LINES TO FLOOR DRAIN. • MAIN MANIFOLD WIRI VALVES BY PASS TO DRAIN � ) DISCHARGE UNE DIMENSION OF OFFSET (AS REQUIRED) T RETURN LINE 2` SLURRY LINE m 'tl C r AT PA 2 RENR 1W lg di / LING - L 1 MOUNT BALL VALVE op VIEW H SIDE UGH DETAIL 0 3 /.41 DRAIN VALVE WITH H OSE CONNECTION. PROVIDE VATS,WATER /GREASE nom CAP. CONNECT: TO' DISHWASHER B PROVIDE •VACUUM. BREAKERS = WITH STRAINERS.OR AIR OAP CONNECTON;A9. REQUIRED BY LOCAL. CODS ; . COMBINRR ° I ' +RESOORE , B TETe ERA E GAUGE TYPICAL CpERAT del NRR ?b ' HAL -' P REU d VALVE! - AI E Tp OOR M " PRESSURE PIPE PRESSURE PIPE PITCH OP PER FT, 10F -2 IDF —I (TYP) Go j r' MO ORIZED VENT' DAMPER GWH - G-1 WIPMFM T Ba 120• WATER HEATER VENT PIPING DETAIL., NO SCALE DION • VA(IAAIT IRE HANG SP HED IT IS OFFSET 8` FROM CENT ER A OF SO SINK EXPOSED PIP ROE IN WALL • WAIL MQINIFO URNS FAUCET / -- EXPOSED PIPE OR REF WAIL INDIICED•ORAFT "!.... FAN INSTALL PER MANUFACTURERS • • RECOMMENDATIONS (TYPO. REFER TO ,. DETAIL 9/M810 FOR MORE INFORMATON eir VENT • ,OUTLET (T(P) , s. 199,000 OWN INPUT EACH WATER HEATER 4• HIGH CONCRETE, • PAD. EXTEND 11` .BEYOND WATER •HEATERS•IN ALL 'DIRECTIONS ESCUTCREN BY' MECHANICA((.. ;' 1CONTRAQI'URj, , .1 LI WINER N'WALL • ' .006 ( CuniTam Group Architecture ' !Mario, Design • - Planning Construction Services 201 MAR Suite 325 NN d9Pdle,: MN - Telephone' 612-379-3400 F9 boss- . • 612-379-4400 Internal: xgrw cuningham.com. e 2/2/0 QAP116 RAB 1' GREASE EXHAUST DUCT — SEE . PLAN FOR SIZE at CONTINUATION GREASE DUCT, PITCH. BACK TO KITCHEN HOOD I /4 PER FOOT. GREASE 11GHT ACCESS DOOR tl ,f lr. h 3/4` DRAIN VALVE IAATNr . IO,tE ' �(" ' /1114414 /1114414 CONNECTION, PRONDE.'YA1ry ODE �jEY1t4 WATER CREASE ROHE 180' SOFTENED HO WATER (180' SHW)' • SHOCK ABSORBER SHOT —OFF VALVE - TYPICAL STRAINER. • PRESSURE REDUCIN WWI HIGH PRER9))If UNION — TYPICAL 12" MIN. FLOOR N- SOMAT I(EY NOTES O THROTTLING VALVE (•). RACKFLOW PREVENTER w/OUILT —IN STRAINER (•). SHOCK ARRESTOR (•). O SOLENOID VALVE (•). O CHECK VALVE — FLANGED SWING TYPE. (•) FLEXIBLE CONNECTOR — FLANGED. (•) O T DRAIN VALVE. (•) O MAKE CONNECTOR TO SPREADER PLATE, O MAKE CONNECTION TO RUSH NOZZLE. FLASH NOZZLE MY SOMAT. 10 PULPER UNIT. (•) EXTRACTOR UNIT. (•) COUPLING. (•) Q ADDITIVE PUMP. (•) O r MOTORIZED VALVE. (•) AIR UNE TO AIR PUMP IN CONTROL PANEL, 20' -0 OF AIR PIPING FURNISHED NI01 CONTROL PANEL, CONTROL PANEL • VAIN 20' -0' COILED AIR PIPING. O CHEMICAL TANK BY OWNER. GREASE DUG NO SCALE • L P ALLEQ• Y' p INSY hiCCH CQNTRAORRR' O NNo ScALLE F �R ' P NG ROWDIER BEARER ETAI 4` FLOOR SINK 8OMAT'IflJN W .90', LONG TURN I. NIBCO#912 COPPER PIPE) T —Y 2. BTOCKVVIIAM 44 (GALVANIZE PIPE) 90' LONG I. NIBCO #007 —LT (COPPER PIPE) RAQIUS. ELBOW 2, BTOCKIIAM /308 (GALVANIZED PIPE) 1, NIBCO #910 (COPPER PIPE) 2. STOCKHAM #350 (GALVANIZED PIPE) EM. DETAIL TANK IEMIOAL N" 2 " — HOSE REEL DETAIL O NO SCALE NOTE; ALL EXPOSED PIPING SHALL BE CHROME PLATED. NQ ALTERNATE FOR PAINTED COPPER. ROT WART, AAET. COLD NA0 CUT • FAUCET AOTATO • 9B RR WOW. . arts; vA L (•) ALL PIPING N EQUIPMENT SHOWN WITH SOLID UNES OR WITH AN ASTERISK ARE FFUURNISHED BY (DEI) THE KITCHEN EQUIPMENT SUPPLIER. 2, REFER TO PEI'S HOSE REEL DETAIL ON SHEET P4 FOR DIMENSIONS & MOUNTING HEIGHTS. 3, ALL PIPING SHOWN NM DASHED LINES & DIE FITTINGS DV THE MECHANICAL CONTRACTOR. ALL EXPOSED PIPING SHALL DE CHROME PLATED. No.. Date DescrAlkn 18/22/98 \' PROPOSAL N!QUEBBI /1 "Q RNK 18 /2 / OB . :.Reg. Na, ,� OL i i, TM • RAINFOREST ` CAFE, Southeenter Mall. Tukwila,, WA" �TV iUHW L. CONSTRUCTION "'' 0 r B0 u A0 BB CO I I I RELAY 0 -30 SECOND DELAY GAS VALVES ARE NORMALLY CLOSED WITH ABSENCE OF VOLTAGE CIRCUIT BREAKER DFTAII $ 120444 IA 13401 111(60. M.13AW 100.44,IA13NP 3MVAC,IA 542101 006040,10 00NIP 101*41A IBNV }141 R[tP1NtE }191 R 4120[ 4-144 A[CBIWL 131169 KtPYAp[ W 301 RF0P1Apf Id-I6P A[NIWE v 0.. 33 MU SE oLTS gym_ RPS I I ITEM KB0 40 01. MIXER 4/ L . __.• -- ITEM K30 DLL CONVEYER OWN T LEAPS IN 6130 TF -1 W IAIA -1 COILS dui PO VU .1_13 E �_1E0 � 41r 120V/10 DEDICATED CIRCUIT FOR HOOD FAN CONTROL BY ELECTRICAL CONTRACTOR v v i, 9 S.r=e .0 011 ■311111101. I 10 1E11 K23 COOK k HOLD 04111 120V110 CIRCUIT 10 11000 LIGHTS BY ELECTRICAL CONTRACTOR ��� 1011111ARKEIHMIBEIHMI ill! — _._ —.—I f _.____.__ —1 C : - _ - �C JL- -- ® ® ITEM 027 ITEM 632 REFRIG. EW19. STAND STEP UP RANGE - B BURNER I %' TATUS VIYM 1 p 1 riaEN'srsroSl nRx6P I3w4n 3613313.304 M1cROW1iCM FOR 3382100W8 ITER 450 CAN RACKS FACTORW RINRINO - IELD i G 2 6 31118FR SUN, =A FILE p4 PREWIRE #33111002 mi I ' tCflffiflIlfil rilftfll itilfiltfi 111 II 1 111111111111111111111111111111111111111111 I�I II II j III M C I WI I I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIll 1111 o 1160 K34 HOT TOP RANGE 0 FINATION 'B' rHFFT 2 ITV 051 DILL CONNECTION OVEN I1EM 435 48' MARIN/OUR } NATION PLA �I� MODEL UDI UTILITY DISTRIBUTION SYSTEM _110 431 hlm 1� Y1ld AMVt :3 303 0 0E)fM OM. OYN. OWI 1206AD 19. 20444 5 -20R DM TYPICAL OF 2 0 0 n II ITEM 454 MOBIL TABLE ITLM K40 CHFESEMELTER =. =. = : := ITEM R36 4B' GRIDDLE ITEM 450 BRAISING PAN UDS FUEL and SHUNT TRIP CONTROL DIAGRAM }164 10. M I I17 4 11 1 021 44l'art Lyzg00 04 621eH 16*40 ITEM 449 4 BURNER RANCE • IE 460 2E K23 301 40 41 40 41 M u 67 6E1 60 7G 80 BO W • 821 401 451 450 419 4 11044 437 ENTER BATTERY 651 60 49 31 40 40 WART MI 004 CCNV. OWN 0BL CONK. 0104 OBL CONE OVEN BRNLNO PAN 00N040 PAN BRN2N0 PAN DAN PAN 4 BURNER NOT OE5CRIP3ON MANUFACTURER IVFR BA RP IYER BATTERY IYEA BATTERY IODIE 121512401101 EQUIPMENT Ilc 632 2 004264 RANGE 126 421 741414 EWIP. 504470 130 030 607107 R OVEN 1301 038 DENWYCR 01014 1b 630 C01YF.YOR OWN 1101 039 CCIIWYOR OWN ES 2 - DC0'S GS I OAS SPARE CS 3/4' CLAD BALER SPARE ITS 3/4 WATER SPARE TOTAL CONNECTED LOAD: F UTURE AVAILABLE LOAD CAPACITY SYSTEM CAPACITY: SERVICE SIZE: 11ER 659 4 BURNER RANCE HOB M/ SOU 8 fl fl M 118 RIBEN0 MB BEND BEND BE BE B ND 0041 BEND 0200 0ANOIN 0110 WAG BLOODETT OWGETT BLOC II BLODGETT ITEM 054 40011 TABLE 0 -340 CA15 05 -20- 01 -20-00 00 -20- O0 0 O0 - 40 201 - 40 ear -1 Ib 445000A 1.2 N 1415CO3AT 1 414 4 5 73 831 SC -40 0011 20- SCBC -60 16 0 DJ 6 FAB 4116280 41 18280 118280 118280 UTILITY DISTRIBUTION SYSTEM EQUIPMENT SCHEDULE 2.9 0 0.95 0.95 404 0.14 0.8 0.0 4.8 ELECTRICAL PS 11 1.9 .B .G 6.2 10 10 0 HP 2102 KW !84 AMPS 118 KW 216 AMPS 2.8 KW 60 AMPS 120/200 V/ 3 PH/ 100 AMPS SYMBOL SCHEDULE 0 C0➢ WATER WARR N RMU as ® 120 VAC 1 PRASE ® 226 VAC 1 PRASE ® 208 VAC 3 PRASE ow 004 3'111ASC co 51FAY SUPPLY e MAN CONOMM16 MUM VOLT 20/ 208 200 20 12.0 120 120 120 20 4ITV 11 g PP'dtlf PH /lik a raw= — ° _ LAP % % V MAY 9 ‘'39 v ide 10 10 10 20 1 808828) Mal PS P0E5 PANT 2 NW AMPS KW AMPS 1/ PH/ AMPS FLAG NOTES 120 /208V /3PH /100A ELECTRICAL SERVICE FRUM ABOVE. 120V /IPH ELECTRICAL CIRCUIT FROM LIGHT SWITCH TO HOOD LIGHTS. 120V /IPH DEDICATED ELECTRICAL CIRCUIT 9000 HOOD FIRE SYSTEN FOR SHUNT TRIP. 120V /IPH DEDICATED CIRCUIT INTO UDS FAN SWITCH FOR FAN CONTROL. 17041420V /IPH 0LS. CIRCUIT FROM UDS FAN SWITCH TO H000 FAN 2' LOOPED GAS SERVICE FROM ABOVE. IN HOT WATER SERVICE FROM ABOVE. 1' COLD WATER SERVICE FROM ABOVE PCL CONSTRUCTION 8000111 Job 52W520 Reviowed 3 M 1 � _ 2 ' — H:•.1.. DIsapproved—...411 L pp- Remarks ILITCNeN 100 RR EIMML BNRE@EM4imt *MEE , A: 0IORMAVNRr *4RISEDITIONTIMKDEMIBEDO YB. AMP 2E 3/4 3/4 I/ 3/4 I/ 3/4 3/4' GAS IW 182 210 120 RS 200 45 160 424 MB 820 NOM 350 MOH 2' IPS UTILITY DISTRIBUTION SYSTEM MODEL UDI IS U.L. LISTED AS A COMMERCIAL APPLIANCE OUTLET CENTER (FILE E81368) PLEASE PROVIDE WITH APPROVED SUBMITTAL CUTSHEETS ON FINAL KITCHEN EQUIPMENT ASSOCIATED WITH THE UDS SO THAT CONNECTION SIZES, TYPES AND LOCATIONS CAN BE VERIFIED BEFORE PRODUCTION. WATER HOT COD UDS CONSTRUCTION TO BE 16 GA., TYPE 304 STAINLESS STEEL I/O 3/4 PPLY STEA AM SUPPLY COND. RETURN CIT VORE∎Re . APR 151559 PERMIT CENTER MAR 12 1999 PCL CONSTRUCTION IRS/11R CONNECTION COflO k 1140 SUPPLIED SUPPLIED FACT WICK OSCWNEC' PPUED SUPPLIED 0100WN IENG CORD k PLUG 0 WICK 0SC01NPC 4' WICK 05CWN PACK LA EC O WN EC' 4 O kM U0 6' CORD k PLUG 8' WICK 0SC0WEC" WICK 00CWNEC 4' WIC% OSCWNEC' 411 05CONNEC' 41106 05CONN 0 WNEC n 50 IL SB 40 CORO *PWO B' n WICK 0SC01NE0 4' COMA 016CWNEC 1' CORD 4 PLUG 6' IL kPU0 IL m Pm O M N 491 L PUIW PH W PU103 NO ES 000 W2L CENMNO 7901IV"' PAGE 1 OF 2 JOB: RAINFOREST CAFE – SOUTH CENTER MALL LOCATION SEATTLE, WA DATE: 01/22/99 JOB # DWG / 122RF —SSI DRAWN BY. SHS r - 1' 1111 III II tl IVI II II II 0 uIIIB Co- 0 0 0 0 p► a' Pnotci-o014) TYPICAL) 0 B' ( O ()ELEVATION "A" O O 27' 6' 1 'e' () ELEVATION "B" O O FLAG NOTES 120 /208V /3PH /IIIOA ELECTRICAL SERVICE FROM ABOVE. I2OV /IPH ELECTRICAL CIRCUIT FROM LIGHT SWITCH TO HOOD LIG C>. 120V /]PH DEDICATED ELECTRICAL CIRCUIT FROM HOOD FIRE SYSTEM FOR SHUNT TRIP. 120V /IPII DEDICATED CIRCUIT INTO UDS FAN SWITCH FOR FAN CONTROL. 120V /IPH CIRCUIT FROM UDS FAN SWITCH TO HOOD FAN CONTROLS. © 2' LOOPED GAS SERVICE FROM ABOVE. I' HOT WATER SERVICE FROM ABOVE. I' COLD WATER SERVICE FROM ABOVE SHUNT TRIP MAIN BREAKER W /RESET HANDLE. 10 ELECTRICAL TERMINAL BLOCKS FOR FIELD CONNECTION. II ELECTRICAL CONNECTION 4 /4EATHERPROUF COVER AS SPECIFIED ON EQUIPMENT SCHEDULE, SHEET I 1R� ELECTRICAL WIRES/AR. I] EMERGENCY KILL SWITCH. GAS RESET, IS HOBO LIGHT SWITCH 4 /WEATHERPROOF COVER. HOOD FAN SWITCH 4 /WEATHERPROOF COVER. 1:>•. REMOTE INDICATOR LIGHTS. ELECTRICAL L BOOR LOAD CENTER LOCATED BEHIND IIINGDED 19C+ PLUMBING , CSHEET 1. ONNECTION AS SPECIFIED ON EQUIPMENT SCHEDULE 10 MANUAL SHUT OFF VALVE, 11 ELECTRICAL GAS VALVE. 13 •PLUMBING UNIONS FOR FIELD CONNECTIONS, �1J UDS RISER EXTENSION. L` REMOVABLE ACCESS PANEL. >.. FIELD JOINT, ,,,ivd innvnln I�I'I'U UVI6 VIM 19 1979 SYMBOL SCHEDULE O 10 0 MMES Of WATER HAIUP.SI OAR m IRO VAC 1 PRASE 101 VAC I ?WI ® 101 VAC 3 PHASE 1213 VAC 3 PRASE Q VOA SUPPLY e SIEAN COODUI$AIE RETURN MEOIEMb MAR 12 1999 PCL CONSTRUCTION cm OFeTUIiOAILA APR 15 1999 PBBMn caa. ,. PAGE 2 OF 2 JOB: RAINFOREST CAFE - SOUTH CENTER MALL ♦ 11 AN ` ewar ■ _ _ _ LOCATION' SEATTLE, WA ( 4P / r � __"_ DATE: 01 /22/99 JOB // FAN UNIT NO, FAN UNIT MODEL N EXHAUST FAN SUPPLY FAN MODEL TAG CFM S.P. RPM H.P. 0 VOLT BLOWER HOUSING TAG CFM S.P. RPM H,P, 0 VOLT 1 NCA24B EF -I NCA24B EF -I 4250 - 1.500' 891 3.000 3 460 41' 32' 36 -3/4' 39 -3/4' 370 000 -222 23 -3/4' 17 -3/4' 54 -3/8' 2 NCA24D EF -2 NCA24B 39 -3/4' 5850 - 1.500' 973 3.000 3 460 37' 43 -1/2' 46 -1/2' 500 600-270 29' 21 -5/8' 58 -1/8' 54' 3 080182 EF -9 000182 550 2800 - 1.500' 1332 2800 3 460 61 -1/2' 64 -1/2' 620 MODEL D A B C D E F G WT. GHD -I22 13 -1/8' 9 -3/4' 46 -3/8' 34 -I /2' 27' 30 -1/2' 33 -1/2' 248 020 -150 16 -1/8' 12' 48 -1/2' 34 -1/2' 29' 30 -1/2' 33 -1/2' 300 GOD -182 19 -1/2' 14 -5/8' 51 -1/8' 41' 32' 36 -3/4' 39 -3/4' 370 000 -222 23 -3/4' 17 -3/4' 54 -3/8' 41' 35' 36 -3/4' 39 -3/4' 450 000 -245 26 -1/4' 19 -5/8' 56 -1/8' 48' 37' 43 -1/2' 46 -1/2' 500 600-270 29' 21 -5/8' 58 -1/8' 54' 39' 49 -1/2' 52 -1/2' 550 000-300 32 -1/4' 23 -3/4' 60 -1/4' 66' 41' 61 -1/2' 64 -1/2' 620 MODEL A 0 C R WEIGHT NCABB 35 23 24.75 7.5 96 NCAIDB 35 23 24,75 11 96 NCAl413 35 23 24.75 15 112 NCAl6B 39 24.5 28,5 18 144 NCA1813 39 24,5 28.5 20 145 NCA24B 46 26,5 ' 33.5 25.5 190 NCA30B 53.5 29 36.5 29.5 219 FAN INFORMATION EF -I & 2 --1► NCA SERIES UPBLAST EXHAUST FANS EXHAUST FAN DIMENSIONAL DATA fln°oog EXHAUST FAN GREASE DRAIN ON FAN AIR INLET OPENING I--- DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FEATURES' - ROOF MOUNTED FANS - RESTAURANT MODEL - UL 762 6 UL 705 - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTION - HIGH HEAT OPERATION (400'F) - GREASE CLASSIFICATION TESTING - CSA APPROVED NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 400'F (204°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION, ABNORMAL Fl ARE -HP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (315'C0 FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS' GREASE CUP HINGED FAN HASP KIT PITCHED CURB INSULATED CURB PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS, SPECIFY PITCH, 12 EXAMPLE■ 7/12 PITCH = 30' SLOPE CURB DIMENSIONAL DATA MODEL NCA9B NCA1OB NCAl4B NCAl6B NCAI8B NCA24B NCA30B 23 23 23 27 27 32,5 35.25 20 20 20 20 20 20 20 VENTED CURB 20 GAUGE ALUMINIZED STEEL CONSTRUCTION 3' CONTINUOUS FLASHING ROOF OPENING DIMENSIONS (D -2) X (0 -2) 4 EP -9 —0. • VENTED BASE NOTE GHD -122 AND GBD -I50 REQUIRE 12' HIGH CURB � F I ALL WELDED STEEL ROOF CURB WITH WOOD NAILER B -� 8' J . MODEL GBO- 122,150 IS 20' A� DISCHARGE SCOOP GREASE RECEPTICAL HINGED ACCESS TO GREASE DUCT / ® /////aNNEMeo ms _ LAM, - or PVT., APR 15 1999 PERMIT CENT, OB RaInf ores t Cafe - Seattle Fans LOCATION DATE' 01/26/1999 ARE U Gu MAR 12 1999 PCL CONSTRUCTION LOB % 0 HOOD NO. fILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM HOBO WEIGH TYPE QTY HEIGHT LENGTH STY TYPE WIRE LOCATION FILE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL A QUANTITY LOCATION 1 SS Baffle 2 20 l6' 3 Incandescent Lights NO 25' 2850 - 0.625' 2280 12' 28' NO 528 LBS, 4 20' 20' 2 SS Baffle I 2U EU 2 Incande NO 2 5430 ND e' 0.00' 700 Deg. NO 380 LBS. 25' 2800 L ights 3 SS Baffle 6 20' 20' 3 Incandescent Lights NO NO 550 LBS. 10 0.00 60 De 3000 4 SS Baffle 5 20' 20' 3 Incandescent Lights NO 0.200' 304 SS Where Exposed RIGHT FRONT NO 483 LBS. 5 SS Baffle 5 20' 20' 3 Incandescent Lights NO 10' 19' 2125 - 0625' 1700 12' NO 483 LBS. 0.200' 304 SS Where Exposed LEFT HOOD N0. MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CONFIGURATION SWITCHES ON H00D TOTAL EXH. CFM RISER(S) TOTAL SUP. CFM RISER(S) END TO END ROW WIDTH LENGTH CFM S.P. WIDTH LENGTH CFM S.P. QUANTITY LOCATION 1 5430 NELS q• 6.00' 600 Deg. 2850 10' 25' 2850 - 0.625' 2280 12' 28' 2280 0.200' 304 SS Where Exposed LEFT FRONT 2 5430 ND e' 0.00' 700 Deg. 2800 10' 25' 2800 - 0.625' 0 304 sr Where Exposed MIDDLE FRONT 3 5430 NELS 10 0.00 60 De 3000 10' 27' 3000 - 0.625' 2400 12' 28' 2400 0.200' 304 SS Where Exposed RIGHT FRONT 4 5430 NELS 8' 6.00' 600 Deg. 2125 10' 19' 2125 - 0625' 1700 12' 20' 1700 0.200' 304 SS Where Exposed LEFT BACK 5 5430 NELS . 8' 6.00' 600 ➢eg. 2125 10' 19' 2125 - 0.625' 1700 12' 20' 1700 0.200' 304 SS Where Exposed RIGHT BACK HOOD INFORMATION HOOD INFORMATION TOP OF HOOD 9 6.00' HOOD D2 HOODS BUTT TOGETHER WITH NO GAP BETWEEN ATING CLIP CONNECTION (SEE DETAIL) PLAN VIEW - 9' 6.00" LONG 5430NELS FENDER WASHER, 318' DIA. THREADED ROD. s 0 MOO DI 44 DOWD DE D /D' CORNER STRIPPING 1 /e• 111111 STRIP DONBECD00 BRACKET *IAD 48' 4 8 0.00 PLAN VIEW - 8' 0.00" LONG 5430ND IMort -(»R PLAN VIEW - 8' 6.00" LONG 5430NELS SUPPLY RISER WITH INTERNAL VOLUME AND FIRE DAMPERS (UL LISTED) REMOVABLE STAINLESS STEEL PERFORATED PANEL PLAN VIEW - 8' 6.00" LONG 5430NELS 10' 0,00' 8 6.00' COMPLETELY INSULATED PLENUM 60 60' 60 60 PLAN VIEW - 10' 0.00" LONG 5430NELS 80' TYP (00W VAPORPROOF INCANDESCENT LIGHT N 11.5' MIN 48' MAX. 63' 1 6 EXHAUST RISER-, r EXHAUST RISER 16' HIGH UL CLASSIFIED HI- VELOCITY CARTRIDGE GREASE FILTERS SLOPED CREASE DRAIN WITH REMOVABLE CUP EQUIPMENT BY OTHERS UDS 16' HIGH UL CLASSIFIED HI- VELOCITY CARTRIDGE GREASE FILTERS — SLOPED GREASE DRAIN WITH REMOVABLE CUP EQUIPMENT BY OTHERS u u u u SECTION VIEW - MODFI, 54.40- (NFI.S 1' FLANGE FOR DUCT CONNECTION ACCESS FOR VOLUME DAMPER ADJUSTMENT SCREW. TO CLOSE DAMPER TURN SCREW COUNTER CLOCKWISE. TO OPEN DAMPER, TURN SCREW CLOCKWISE. (NOTE DAMPER ASSEMBLIES LONGER THAN 24' HAVE TWO ODD - ADJUSTMENT MUST DE MADE AT DUTH ENDS) 6.25' NO Laval is v.. 100W VAPORPROOF INCANDESCENT LIGHT HANGING ANGLE DETAIL 2' M� )1.5' MIN 48' MAX. 80' MODEL 'ND N NELS' EXHAUST HOODS ARE U.L. LISTED FOR USE OVER COMMERCIAL COOKING APPLIANCES BY UNDERWRITER'S LABORATORIES IN ACCORDANCE WITH NFPA STANDARD NO. 96 U.L. FILE D' MH12106 OPPOSED BLADE VOLUME DAMPER 3.5' NOM TYP U.L. FIRE DAMPER (INSIDE) WITH 212 DEG. FUSIBLE LINK SUPPLY RISER WITH INTERNAL VOLUME AND FIRE DAMPERS (UL LISTED) REMOVABLE STAINLESS STEEL PERFORATED PANEL COMPLETELY INSULATED PLENUM BOLTS (OR THREADED ROD) AND NUTS SUPPLIED BY CONTRACTOR STEEL ANGLE WELDED TO END OF EACH HOOD TO BE BOLTED TOGETHER TO DRAW HOODS FLUSH TOGETHER SEE DETAIL ILL USA Imndouoa UBHu HOOD DI 57 57' 57 57' Hood #2 ""1111 OPP IIIIIIIIIIIIIIIIIIIIIIBI,. L__ 25 . _A 111111IIIII 0 U.L. U.w SnuMnw. MOa. U.L U¢d 1maderna,118Bo _IIIIIIIIIIIIIIIIU ,1611iiiiH11 ool.,. _ I,IIII�uimiIuOi 19' Illlllllllllllluuu 10' 0 U.L. Lied Ineuxlcouna UBN, 1/2' DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE STEEL HANGING ANGLE 1/2' DIA. HEAVY DUTY NUT ONE ABOVE AND ONE BELOW HANGING ANGLE ROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE - PUNCHED AT FACTORY DETAIL OF SUPPLY AIR VOLUME AND FIRE DAMPER ASSEMBLY JOB Rainforest Cafe - Seattle LOCATION I' FLANGE FOR CONNECTION TO HOOD EXTENDS BELOW TOP OF HOOD MAR 1 Z 1899 PCL CONSTRUCTION BATE' 01/21/1999 JOB J/ 0 /JW/T ,Y I ?1CRAI. I /J/R4 WN 9Y 1 '1'11 nAl 1 9 1995 j, - . I. U1v C, DIVISI 0 'MLA AP 1 5 1999 PE'MIT CENTER 13 K14 615 16 17 18 K26 K27 K28 K29 K30 K31 K32 K33 K34 K35 K36 K37 K38 K39 K40 K41 K42 K43 K44 K45 K46 K47 K48 K49 K50 52 53 54 55 K56 57 58 59 60 61 62 63 64 65 66 K67 68 69 K 78 K 79 K 80 K81 K 82 K 83 K 84 6 85 K 86 K 87 I LOT 1 is 1 I LOT 1 I LOT I LOT s a 1 I LOT 1 LOT 4 I OT 1 0 K 08 K 89 K 90 K91 10 K 92 OPEN NUMBER POT RACK LIMIT SWITCH CORNER GUARDS PRINTER STANDS TRAY HOLDER 1111 OPEN NUMBER MEMO -- EMJAC BY G. C. METRO EMJAC EMJAC EMJAC EMJAC T &S CAMBRO VICTORY WINSTON EMJAC EMJAC HATCO EMJAC ATLAS METAL CAPTIVE AIR CAPTIVE AIR RANKIN DELUX HATCO SOUTHBENS SOUTHBEND SOVTHBENO RICOH BLODGETT SOUTHOEND EMJAC EMJAC EMJAC EMJAC TOASTMASTER EMJAC SILVER KING EMJAC SOUTHBENS SOUTHBENS SOUTHDEND EMJAC T &S EMJAC EMJAC HOBART HOBART EMJAC HOBART RUBBERMAID EMJAC KROWNE T&3 EMJAC BY G. C. EMJAC KELVINATOR T &S EMJAC G. C. EMJAC TKS AMANA ATLAS EMJAC VICTORY KAIRAK EMJAC EMJAC MANNHART HATCO HATCO FMP HATCO EMJAC EMJAC EMJAC EMJAC EMJAC METRO MAX 0 SP75UDT' FAB CRS66 A FAB METRO MAX 0, FAB FAB FAB FAB NSF RA -I0 -07 CA7522 FAB FAB CUSTOM FAB WIHDM -3 FAB CUSTOM ORSU 636 C S 36 162 -0 SCBC-60 SG -48 NI445C3BAT MT1828G CM3I -W FAB FAB FAB FAB 30840 FAB SK2SB FAB 1364 BGLT -40 GS -20 -SC FAD FAB FAD FP 61 1912E FAB D -340 3600 FAB HS 2 111400 FAB FAB 014 NSF FAB FAB NSF RFSI IB WIHD -I FAB FA -ID-S7 CUSTOM FAB FAB SO -97 GRAM FAB DIP I AL FAB FAB FAB FAB FAB 6. 5 27. 2 200 14 0 2. 0 SINGLE HEAT LAMPS OPEN NUMBER LIGHT FR ES WIRED TO PANEL 'A' SEE SHOP DRAWINGS WIRED TO PANEL 'B' SEE SHOP DRAWINGS WIRE TO DISHWASHER SEE SHOP DRAWINGS SEE SHOP DRAWINGS SEE SHOP DRAWINGS 1011113131 -- ms E I B2 83 B4 B5 B6 B7 88 B9 B10 518 Bl9 B20 B21 022 B24 B25 B26 B27 528 029 S6 S7 S8 S9 S10 Sll S2 S3 S4 SII 012 DRAIN TRAY OPEN NUMBER SINGLE SPEED RAIL THREE COMPARTMENT SINK SINGLE SPEED RAIL BACK BAR COOLER VEGETABLE JUICER UNDER COUNTER REFRIGERATOR SLUSH MACHINE OPEN NUMBER OPEN NUMBER YOGURT MACHINE OPEN NUMBER OPEN NUMBER OPEN NUMBER FILLER PANELS /ONE WITH HAND SINK SERVICE STATION 'A' STAINLESS STEEL SERVICE COUNTER P0S SYSTEM WALL MOUNT OVERSHELVES COFFEE GRINDER COFFEE MAKER MILK DISPENSER ICE TEA BREWER SODA DISPENSER NIGH CHAIRS HAND SINK CARBONATOR DECK MOUNT FAUCETS ESPRESSO MACHINE W /FRIGOMILK SERVICE STATION 'B' STAINLESS STEEL SERVICE COUNTER P0S SYSTEM WALL MOUNT OVERSHELVES COFFEE GRINDER COFFEE MAKER OPEN NUMBER ICE TEA BREWER SODA DISPENSER OPEN NUMBER HAND SINK CARBONATOR DECK MOUNT FAUCET EMJAC EMJAC GRINDMASTER GEMINI SILVERKING BLOOMFIELD COKACOLA EMJAC COCACOLA T &S EMJAC COCACOLA T &S SP KR1853C SP C5064ESCHP N350 UR27SST 390 CUSTOM 3023 P MIX FAD CBFF100 NSF Bl4 DID B16 BIT i 2 I LOT ®a 1 1 I LOT ®s .. 2 I LOT HIM KROWNE KROWNE PERLICK RUBBERMAID KROWNE KROWNE KROWNE KM DANE KROWNE KROWNE KROWNE PERLICK NUTRIFASTER VICTORY TAYLOR TAYLOR KROWNE EMJAC EMJAC GRINDMASTER GEMINI BLOOMFIELD COKACOLA ©_112111 W + ®�_� ® =__ - - - - - -- 112 1 12' /2' 1'FS 60 11111® ■11 ■ ■. -- - - - - -- - FS 1 V2' 11111 20 1 5. 11 11 1 1 208 60 1 29.0 20 60 1.7 20 60 1 3 120 60 51$ 120 - - - -- NNW ;20 60 _I 10.0 ....- 0 ® ■■� u■ai.I Uh1I11II 250 GEM - 12 SK -I 8742 3023 P MIX FAB CBFF100 M50 LIGHT FAB FAD 250 GEM -12 8742 1 6U 20 6. 4 15. 0 BY OWNER /PLUG BY E. C. SEE SHOP DRAWINGS BY OWNER SEE SHOP DRAWINGS BY OWNER BY OWNER /CORD & PLUG BY E. C, BY OWNER BY OWNER SEE SHOP DRAWINGS BY OWNER SEE SPECS 1I .�■ Ciri■■�11 -1. CORD AND PLUG BY OWNER CORD AND PLUG SUPPLIED BY VENDER /CORD & PLUG BY E CORD & PLUG BY E. C. SEE SHOP DRAWINGS BY OWNER SEE SHOP DRAWINGS BY OWNER BY OWNER /CORD & PLUG BY E.C. BY OWNER BY OWNER BY OWNER SEE SHOP DRAWINGS BY OWNER SEE SPECS )IVI N 0. STY KI K2 K3 I K4 I K5 1 K6 1 (3 ) ICE MACHINE HEAD WITH (2) BINS I LOT BAG IN TH BO LOT SHELVING LOT COOLER /FEEZER COMBO LOT DRY STORAGE ROOM TOP TRACK SHELVING COOLER /FREEZER SHELVING CHEF'S OFFICE SOMAT SYSTEM SOMAT ROOM LOT CLEAN DISH TABLE DISH MACHINE SOILED DISH TABLE LIQUOR STORAGE MOO OPEN NUMBER WALL MOUNT SHELF 3 COMPARTMENT SINK WALL MOUNTED OVERSHELVES FRYER CUTTING BOARD PRERINSE SPRAY DUNNAGE RACKS REFRIGERATOR COOK AND HOLD OVE EFRIGERATED COUNTER VENT RISERS TRIPLE HEAT LAMPS AND LIGHTS REFRIGERATED EQUIPMENT STAND (UNDER EQUIPMENT) HOT FOOD 3 WELL DROP-IN OPEN NUMBER EXHAUST HOOD UTILITY DISTRIBUTION SYSTE STEP UP RANGE 6 BURNER BOOSTER HEATER HOT TOP RANGE 60' CHARBROILER 48' GRIDDLE FRYER BATTERY OPEN NUMBER DOUBLE DECK CONVEYOR OVEN /STAND CHEEZE MELTER CHEESE MELTER SHELVES REFRIGERATED SALAD AND DESSERT COUNTER 42' HIGH TAKE OUT TABLE WORK TABLE 2 DRAWER FOOD WARMER WITH CASTERS ORK TABLE LETTUCE CRISPER 0 -A TABLE 4 BURNER RANGE WITH CASTER BRAISING PAN DOUBLE DECK CONVECTION OVEN W /CASTERS SILVER SORTING TABLE ON CASTERS DECK MOUNT /PRERINSE /ADD A FAUCET MOBILE TABLE BRACKET FOR FAUCET FOOD PROCESSOR FOOD SLICER CAN RACKS MOBILE TABLE 40 OT, MIXER WITH HUB ATTACHMENTS INGREDIENT BINS WALL MOUNTED SHELVES WALL MOUNTED HAND SINK WALL MOUNTED HOSE REELS ORK TABLE C0/2 TANK MOP SINK WORK TABLE WITH DOUBLE SINK ICE CREAM CABINET BACK SPLASH MOUNT FAUCET ELECTRICAL PANELS FLOOR TROUGH STAINLESS STEEL WALL COVERINGS BACK SPLASH PRERINSE W/ADD A FAUCET ICROWAVE OVENS HOT FOOD WELL PPM= ORKTABLE SINGLE DOOR FREEZER REFRIGERATED RACK SYSTEM MOBILE ICE PAN WORK TABLE SALAD SPINNER HEAT LAMPS AND LIGHTS DIPPER WELL TE DISCRIPT ION MANUFACTUER MODEL ND, HOSHIZAKI KM- 1600SRE3 \5130 COCA -COLA M ETRO EMJAC BY EC ETRO ETRO GC. SOMAT BY U.0 EMJAC HD BART HLI METRO MAX 0 FAB METRO AA 0 ATER GAS H C DRAIN SIZE MBTU VOLTS 3/4' F, S ON. 0 208 CYL 60 ELECTRICAL PHASE 3 ® • ® ®. C 11 1 120 60 208 60 120/208 60 1 6 120 60 CONNEC 208 60 12. 3 1, 299 120/200 60 1 00 60 43.0 4 5 20 1 120 1 1 1 1111 2 2 7 04 7 0 60 10 66 '2120/201 60 5. 0 25 CON. D. 120/208 60 125 208 60 4.09 120 60 2. 4 NM I SEE 085 1111 185 120 60 6.2 100 120 60 7.0 - - - ® -®' I_ 7.9 ....■■,.. ••••• 120 601M ■■ 120 60 1111 111111111 208 60I ®MM 11111. CC®C11I ■. ® ® ®■- 120 60 1 120 60 120 60 120 60 1 11 7. 9 SEE SHOP 120 60 I 6.0 208 60 I 120/208 60 1 120 60 1 2.5 MEE NE MEM 1! 111111 NE 1 r_I r- �:.7_T - �i1►...A.W1/,I��iIri ' 1 —■ ■1 -I IMO h I11N1EWA MI AMPS. II.5 PROVIDE 20 AMP CIRCUIT /REMOTECONDENSER BY VENDER REFER TO REFRIGERATION RACK & WALK -IN DWGS,ELECTRICAL SPCS. SEE KITCHEN LAYOUT PAGE K2 SEE KITCHEN LAYOUT PAGE K2 SEE SOMAT SHOP DRAWINGS SEE LAYOUT PAGE K2 SEE SHOP DRAWINGS SEE SPEC. SEE SHOP DRAWINGS SEE LAYOUT PAGE K2 SEE LAYOUT PAGE K2 SEE SHOP DRAWINGS SEE SHOP DRAWINGS SEE SHOP DRAWINGS SEE SHOP DRAWINGS SEE SPECS CONNECT TO UDS /PG. E3 SPECIAL NOTE NI SEE PANEL 'A" SHOP DRAWINGS SEE SHOP DRAWINGS WIRED TO PANEL 'A' T TO UDS/PG. E3 SPC. NOTE DI /SHOP DWG IRED TO PANEL 'A' SEE SHOP DRAWINGS 100 SEE SHOP DRAWINGS CONNECT TO UDS SEE SPEC, CONNECT TO UDS CONNECT TO UDS CONNECT TO UDS CONNECT TO UDS /PG. E3 SPECIAL NOTE CONNECT TO UDS /PG. E3 SPECIAL NOTE CONNECT TO UDS SEE SHOP DRAWINGS SEE PANEL 'B' SHOP DRAWINGS SEE SHOP BRA WINGS SEE SHOP DRAWINGS IRED TO PANEL 'B' SEE SHOP DRAWINGS WIRED TO PANEL 'B' WIRED TO PANEL 'A' CONNECT TO UDS /PG. CONNECT TO UDS /PG. CONNECT TO UOS /PG SEE SHOP DRAWINGS SEE SPCS SEE SHOP DRAW SEE SHOP DRAWINGS CORD & PLUG CORD & PLUG BY OWNER SEE SHOP DRAW CONNECT TO UDS /P6.E3 SPECIAL NOTE B BY OWNER SEE SHOP DRAWINGS SEE SHOP DRAWINGS REMARKS E3 SPECIAL NOTE E3 SPECIAL NOTE E3 SPECIAL NOTE B BY VENDER /VERIFY LOCATION BY ARCHT. SEE SHOP DRAWINGS WIRED TO PANEL 'B' SEE SPECS SEE SHDP DRAWINGS PANELS 'A&B' SEE SHOP DRAWINGS SEE SPCS SEE PANELS 'A&B SHOP DRAWINGS WIRED TO PANEL 'B' SEE SHOP DRAWINGS WIRE TO PANEL 'B' DWG FOR ELECTRICAL SPECIFICATIONS, SEE SHOP DRAWINGS SEE SHOP DRAWINGS IRED TO PANEL 'A' IQ HAND SINK ICE BIN BOTTLE COOLER OPEN NUMBER [ =1 DISCRIPT ION MUSHROOM BAR BAR MILL WORK OPEN NUMBER SLIM JIM TRASH CAN BLENDER STATION 24' ICE BIN DOUBLE SPEED RAIL PUS SYSTEM OPEN NUMBER OPEN NUMBER ITEM ANUFACTUER MODEL NO, CUSTOM KR1848DPC8P 7260E R 24 DS KRIB36DPCOP SP ATER GAS ELECTRICAL p)U1 BY OWNER CORD AND PLUG DUPLEX RECEPTACLE BY OWNER REMARKS 199 RECEIVE OF TUM 151 MR CE N EF \ \ \ \ \ \ 00 goo \ N(4 4wi REVISIONS 02/15/99 FOR MIKE MCKINNON DIR FOOD AND BEVERAGE N Q N\ CD 0 0 p l0 Q O VI C 0 0 G■ 3 ox.wwa A 4-98017 SHEET EQUIPMENT SCHEDULE en SHEET 1 OF 15 \V EOMAT RFC SNNAT SY IIIIIILgIIIII!] LIQUOR STORAGE �� rAallirarzal a.1 uuuu — ttt. MI BOW 111111D011111 1111111N lllllllll `7 VW � �1.I ■ ■ +HWO a illillial' Aa ca Au Aa v�%y A;a vk f all .. V ii ^ —� TT�'Ti�i' �� III II 74,:trifiEng �! I!ti...•. a� J L ca Ai ca Am I a i' •r FY/ .0 0 N4/ r � •Y/ Aril. -4i I TEN TS/ • fig :j A I !TJT WV VW ANL ■ ■ I AINTENANC ROOM CORRIDOR L_J SERVICE AREA "A" 124 I T • d ® d KITCHEN I 129 I La Ai A& A;a f.1 A:"1 La &L A& C1Lta i r/ y tn1v iir A 87 ry 1W7 Fill JL / VLY •DB 114 u / I I a A7 Aa A7 A;a A* AA A'a AA AAI, A ANL Y VW VF7 TI7 rVW VW r417p VEY 1,1W 1,1W NW VW [b7 1! © --' -- - -- IRE y fit II I I 111111 I III�� JA AAL A ∎ -.. A,a. IN? FU [II 10? A% Aa Ca AA VW TO 65/ MD7 dra S L.. IX T A T i ii CI AOL i�1 Ttr • [II A;a 'r FRE EZER A Y N 0 0 W N O Z 0 W M a Q 0 N ✓ & Cl °m N O N rr O °r m O 0‘1...1 z m °� O J m 0 M 2 r wiNO I 4 -98017 AL R eEr EQUIPMENT LAYOUT ZS2� LJ OK DT 2 Ui 16 rngq -ooR I SPECIAL NOTE SUBCONTRACTORS TO VERIFY ELECTRICAL AND PLUMBING HOOK UPS WITH GENERAL CONTRACTOR AND KITCHEN EQUIPMENT CONTRACTOR SPECIAL NOTE THIS PLAN FOR LOCATION AND TYPE OF EQUIPMENT ONLY REVISION t6 MOVE TAKE OUT TABLE, ADD HANUSINK AND ADD VURK SEE CLOUDS ON PG. K2 AND CHECK ALL OTHER PAGES RELATES 10 ROUGH -IN AND DIMENSIONS. WALL NW SEE SHOP DRAWINGS FOR REMOTE REFRIGERATION EQUIPMENT REMOTE REFRIGERATION NOTES NOTE REMOTE REFRIGERATION SYSTEMS WILL BE RACK SYSTEMS. CIRCUIT CONDENSER WILL BE LOCATED ON THE ROOF ABOVE NOTE ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT FOR WIRING TO REMOTE CONDENSER, SEE SPEC SHEETS ON FOR COW` n IE MACHINE R REQUIREMENTS. (208V/60/30/90.0 AMP, MAT,U SIZE AND WEIGHT OF THIS UNIT WILL DE PROVIDED ON SHOP DRAWINGS REFRIGERATION RACK SYSTEM coy APR PROM O \ N 0 N N N REVISIONS 02/15/99 FOR MIKE MCKINNON DIR FOOD AND BEVERAGE E NL 0 vu • 4 0 • r c g w a Z 0