HomeMy WebLinkAboutPermit M99-0092 - HARTUNG GLASS COMPANYi.'" i' �gi�l" ��y,•: tii«"t:.' kW∎r,3/.34":V,N5t?gn"J
M99 -0092
17830 West Valley
Hwy.
Hartung Glass Co.
City of Tukwila ( C.. (206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
MECHANICAL PERMIT
Permit No: M99 -0092
Type: B -MECH
Category: NRES
Address: 17830 WEST VALLEY HY
Location:
Parcel #: 362304 -9097
Contractor License No:
TENANT
OWNER
CONTACT
CONTRACTOR
HARTUNG GLASS COMPANY
17830 WEST VALLEY HY, TUKWILA, WA 98168
SCIOLA NICK +PATRICIA ANN
6718 134TH CT NE, REDMOND WA 98052
PAUL OLSEN /UNIV. REFRIGERATION:
4101 "8" PLACE NW, AUBURN, WA 98001
UNIVERSAL' REFRIGERATION, INC.
4101 "6" PLACE NW, AUBURN, WA 98001,
*" k* k**************** k" k****************• k**** k*** *•k******** ** * ****** **•k*** ***
Permit Description:
Status: ISSUED
Issued: 05/25/1999
Expires: 11/21/1999..
Phone:
Phone: (206)656 -2626
Phone: 253 -939 -5501
Phone: 253 -939 -5501
DPLIT":N SYSTEM .HEAT PUMP, AUX. HEATER„ OSA
MOTORIZED DAMPER, PROGRAMMABLE T-STAT & DUCT,
GRILLES AND REGISTERS..
UMC Edition: 1997
****• k****** *•k * ** * ** *•k ** **•k * * * * *•k * * *.•k
Valuation:,
Total Permit Fee:
* *•k * * *k k*. * *k * ** * * * *•** * * * ** * * * * * * ** ***
6.,076.00
46.50
Permit Center Authdrized Signature Date
I hereby certify'that I have'readandexamined.this permit and .know the
same to be .true and correct. All provisions Of law and ordinances
governing this work will be complied with, whether specified herein or not.
The gran'tir►g of this permit does not presume• to give authority' to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this buildin
51gnatur
Print Name:
Title:
This permit shall become null and void :if the work is not commenced within
180 days from the date of i ssuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
CITY OF TUKWILA
Address: 17830 WEST VALLEY HY
Suite:
Tenant: HARTUNG GLASS COMPANY Status: ISSUED.
Type: B-MECH Applied: 05/04/1999
Parcel #: 362304-9097 Issued: 05/25/1999
kh*k******kkk**Akk***klekAAkA******00***Ailk*********4.—kli***k******kk***
Permit Conditions:
1. •Readily accessible access to roof mounted equipment is
required.
2. Electrical permits sha:1A:,blespbteAtie*thrbu,g0 the Washington
State Division of,L:06r,-;40'd
work will be in4-4bted by ,that. agency
No changes wylrge" made plans unless.vapprO■ied by the
Engineer and the Tuk.:Wita',J(011ding' Difls ion.
4 All permitsinsPeCOon record ,,and appro‘ked,Oans,s0a11 he
available at the fob site prior to the startq-of'apycbh
structi6n. Thes'e—documents are .,to be maintained and aV-401-
able unt.11 flnal inspection aPproval is granted.,,
5. All construction to be done An conformance with, app'roved,
plans/and, requirementsof. etie Untform Building Code (1997\,
Edition) as amended,Unifor4,1Mechanical Code (1997 Edition) „
ane,Wash:ington-Statefnergy Code (4997 Edition).
6. Validltyopf:Permit. The isSuance 9f a permit or approval of
plans, specificattons, and Computat;lionS' 'shall not be con-,
st6ed to be a permit forforlan-appr9Val'of, any vioiatibn
of:ihyof„the provisions Ofc'tthe'liung cbde or of",!any,
other ordinance' of the jilidictifbn?,2 No permit presumingtb:
914:awthOritiY violaite, or canbel-the provisions of this
code shall be valt4.: ,
7. Manisfacturers.installation instil.pCtiChS.,requtired on site
fork'the'ibOildinq inspectors revlek '
1, k
04,r At
' e
0
Permit No: M99-0092
•
CITY OF T'IKWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
F1 - STAFF USE ONLY
Project Number: i
Permit Number: % 1 19 `f DV ► L
Miscellaneous Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mall or facsimile.
Project Name/Tenant:
10.r-EvA CTtc�ss Coiv o N5 t
Value of Construction:
4 t_o o7Co .Oc9
Tax Parcel Number:
3(42ao4 -90 17
Phone:
Fax #:
P one:
255)- 9 3q - S S-01-
ax #:
�2c7, -73C- 3 2-
Site Address:
(1a3o Weil- \Alley 1- 4-i5\tiuJay
City State /Zip:
, TukwiLA q
i c, i rel- ANA)
City State /Zip:
F42.tC C-- 244Tion-- TI QC- .
Property Owner:
S c I o L A fO tC.V-- .-4- PATfz
Street Address:
Contact Person: UNNEr'SC1
rte , es —, J A
Street Address:
"R"
City State /Zip:
Ao8��2r i. t� A �I�c�01
Contractor:
t.1n lQ6(2- a t-- (zt�rt216-E2ATIOVJ ZNC .
Phone:
('253 ) 939 - 5502
Street Address: City State /Zip:
41-1. O "13" R.-ACE N(k) A ut3 a2f. , WA ''31800-1-
fax #:
(253 7 3 5
DAVID Ket -lt„_E
0 Water
Phone:
(2- 01,2)- X33 - g95?
Fax #:
(Z,.- ,Z
Street Address: City State /Zip:
12720 Ca ''6tiA- l .V. Sur Ut , SE t '`Mo
Engineer:
.
__
Phone:
Street Address:
City State /Zip:
Fax #:
MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) ,
Description of work to be done: SPLIT 5ci5T6A' HEAT -,....nn(' ,Awe . • -r6rl -, OSA ►MOT ,2.I Wrb 0.gmp6a-,.
Qror'Aw.r ,se.■■e_. T S+-..-1-, If. 'Doe--1- , Grr tl CS c0.3 a. i b-kr-S .
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ino
Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets
❑ Above Ground Tanks 0 Antennas /Satellite Dishes ❑ Bulkhead /Docks ❑ Commercial Reroof
❑ Demolition ❑ Fence Mechanical ❑ Manufactured Housing - Replacement only
❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems
❑ Temporary Facilities ❑ Tree Cutting
APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS
❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s):
❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing
❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public
❑ Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only
❑ Water Meter /Permanent # Size(s):
❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule:
❑ Miscellaneous ❑ Moving Oversized Load /Hauling
MONTHLY SERVICE BILLINGS TO:
Date appll
a on ties: es:
Name:
t
n by: (initials)
Phone:
Address:
City /State /Zip:
0 Water
0 Sewer
0 Metro
0 Standby
WATER METER DEPOSIT /REFUND BILLING:
Name:
Address:
IPhone:
City /State /Zip:
Value of Construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and Is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall
expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days
upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application
shall be extended more than once.
Date • • • cat n cce
Date appll
a on ties: es:
Appllc
t
n by: (initials)
MISCPM7'.DOC 7/11/96
ALL MISCELLANEOUS P ' T APPLICATIONS MUST BE SUS ED WITH THE FOLLOWING:
➢ ALL DRAWINGS SHALL BE AT A LEGIBLE'SCALE AND NEATLY DRAWN
➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT
➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON
LICENSED STRUCTURAL ENGINEER
➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER
(P.E.)
Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS
PERMIT.
BUILDING OWNER.O,R_AUTH
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW
0
Above Ground Tanks/Water Tanks - Supported directly upon grade
exceeding 5,000 gallons and a ratio of height to diameter or width
which exceeds 2:1
Submit checklist No: M -9
71
Antennas /Satellite Dishes •
Submit checklist No: M -1
El
Awnings /Canopies - No signage
Commercial Tenant Improvement.
Permit
�/
Bulkhead /Dock
Submit checklist . No: M -10.
(253)735,3{•3
Commercial Reroof.
Submit checklist No: M -6
0
Demolition
Submit checklist . No: M -3, .M-3a.
O
Fences - Over 6 feet in Height.
Submit checklist No: M -9
0
Land Altering/Grading/Preloads
Submit checklist No: M -2
Loading Docks
Commercial Tenant Improvement
Permit. Submit checklist No: H -17
t,
Mechanical (Residential & Commercial)
Submit checklist• No. M -8,
Residential only - H -6,, H -16
0
Miscellaneous Public Works Permits
Submit checklist No H -9 ,
71
Manufactured Housing (RED INSIGNIA ONLY).
Submit checklist . No M -5
Moving.Oversized Load /Hauling
Submit checklist No: M -5
ri
Parking Lots
Submit checklist No: M -4
Residehtial'Reroof - Exempt with following exception: If roof structure
to be re• aired .or re laced
Residential Building Permit
Submit checklist No:. M -6
Retaining Walls - Over 4 feet in height
Submit checklist No: M -1
0
Temporary Facilities :
Submit checklist . No: M -7
Temporary Pedestrian Protection/Exit Systems
Submit checklist No M =4
0
Tree Cutting
Submit checklist No: M -2
Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS
PERMIT.
BUILDING OWNER.O,R_AUTH
IZED AGENT:
Signature: �/
L- .1c w �..
Date: 05- 63^'99
Print name
'
Phan Fax #
o,��
�/
L-- �CSCLi! /w�gc,�3)93`t
-55oi
(253)735,3{•3
Address: ON t V6/L6714
t Feb4E.24Ti o NC-.
City /State /Zip:AUg ore
(AA 95011- O• I 4'
MISCPMT.DOC 7/11/96
• 1r*..A** 4***+ V **,$+11**AAA,4:4* *o * *It,4 *h** std *k * *4e *AA *o *“*A•ki*o * *Aki$,*
TRANSMIT
CITY OF TUKWILA, WA
_� * *�� {�f *stk•A•A�!{4*s1d4* * *�h1,fi�• �l* 4*1k **sl+h* k01*et4A*k*kkiki* *A*
TRANSMIT Number: R9E300072 Amount: 46.50 05/25/99 10: 9
Payment Method: CHECK Notation: AINIVERSAL RE:F'R18 •in7t;: CAS
Permit Nof M99 -0092 type: B -MECH MECHANICAL PERMIT
Parcel NO: 362304 -9097
rite . Addrea > c 17820 WEST VALLEY HY. +. � f
Tots l I� {eds : 46..50.
This Payment ! A6..50 Tutad ALLY Pmts: '46.50
. U al ance: .041
*4t•k.A )k* * *'A *•o\ ** • ot1k*•* k% yt*A A •;4 **It•h * * *:4 *1fi * *4*•1•fi4A * *• *A **Alt * * ** *h*4**
Account Code Description Amount
000/2-45.820 PLAN. CHECK -- MCNEES 9.30
• 000/322.100 MECHANICAL NONRUS 37.20
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 981
INSPECTION RECORD
Retain a copy with permit
..,ca�,,%i+�'„
PERMIT NO.
(206)431 -3670
Proje t:
Type of n p ctio "
/7 S�
�
Date called:
Special instructio s:
A
Date wan/t��d:'
(!�
a.m.
p.m.
Reque ; _ G
Phone:
pproved per applicable codes. 0 Corrections required prior to approval.
COMMENTS: (91M56 geig j
77) 64974g, /Vcr-r-
Ei $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
Receipt No:
Date:
' r ' Lx:��1 °^?iei. ' �K�2 ksd� tStbiwa A rsi�i3Li�.
,ttawh.. .. ..:
INS CTION NO.
Sr" 1 ;1.- ••
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
PERMIT NO.
(206)431-3670
Prjct:
0" (-1C1C35
fJnspectiqn: ,, ,,
\ na \ — 1— krf6h
I
Va1leu h
ate called:
(0- 1 -q °I
Special instructions:
Date wanted&,-.0
Reqt0r:
ne 1)64)1C/k
ElApproved per applicable Ies,
rrections required prior to approval.
COMMENTS:
77e.5 OeCeeti C;1004
0 isiieltle,Fir -*` -/te
442-44-. /614 X- e1e77C0c...
•.
Li $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
. • . A •
• 1t.;.'
21)
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
140°- 00 9.2
PERMIT NO.
(206)431-3670
Project:1.4.4. ,
7V1,--C 67
. Type det,
Adcirrypi ....&,0
6,-) t/ Al
Date called:
Special instructions:
300 KEI
Date wv
Requester:
Phone:
4
riApproved per applicable codes,
rections required prior to approval.
COMMENTS: . .
c-rOPPM) 121.41 ' /*VA'. 70
04e-Cle- 7 ee-S5 age 7-x•sr
&a46--e---- 4--7" 4-661/4/r 75 ficz-
/14 vtr- ri-sr 70 ,E00/14,faitir
/144-)‹ ----' A.044/1. Pr.,4-7-i., 5M7-4S
300 KEI
0A-u- tAM-ined 12-4-14-4
AJOTC-_ 1-2 vr i4zis ,,e,--e6PWE2 ›
,,\.. pta,,,A- q 0 xm-- ow
sii740,
$47.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Dare:
Receipt No:
• •!..4.•tP.• t
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
\‘\tk
6300 Southcenter Blvd, #100, Tukwila, WA 9818S
INSPECTION RECORD
Retain a copy with permit
/1C?-vov-
PERMIT NO.
(206)431-3670
ProjegaRtju tic ._ 6_70 .
Tre3ftlinesvalippiic, geki
Ad ress 0 vcj. vo fie A
Date called: /, / /
6 ea/V-'''.
Spe.,jal instructions:
\
\
\17
.
Date wanted Afrh a A,:a".1.-)n
/ p.m.
Requestetrer. r■ Or CI Cl/
Phone 59 SO/
Aprioved peapplicable codes.
orrections required prior to approval.
COMMENTS:
ake_
?4663,e--L) /(50 ps.T-
lnspe
Date.
El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reins ection.
Receipt No:
Date:
jf
•
It •
Carrier
HEATING & COOLING
Product 38YKC (60 Hz)
Data Heat Pump
Sizes 018 thru 060
rot,' 1 r)r)(i (MIIIr r rr irnr1171111111
RECEIVED
CITY OF TUKWILA
MAY 0 '4 1999
PERMIT CENTER
The 38YKC Outdoor Sections of
Split - System Heat Pumps are designed
for quiet, reliable heating during the
winter and cooling during the summer.
These heat pump systems provide
economy of operation through energy
conservation. These units provide
SEER ratings up to 11.5 and HSPF up
to 8.5 when used with components
designated by manufacturer. They
recover heat for indoor comfort from
outdoor air during the heating season
and, by automatically reversing the
refrigerant cycle, remove indoor heat
and excess humidity during the
cooling season. All models are
listed with ART, UL, c -UL, CEC, and
CSA -EEV. All models are offered in
208/230v.
FEATURES /BENEFITS
Compressor — Each compressor is
mounted on rubber isolators for
additional sound reduction.
Continuous operation is approved
down to –30 °F (- 34.4 °C) in the
heating mode and down to 55 °F
(12.8 °C) in the cooling mode. (See
heating and cooling performance
tables.)
Built -In- Reliability Components —
Includes a suction accumulator that
minimizes the amount of liquid
refrigerant that reaches the
compressor; loss of charge protection;
start thermistor and crankcase heater
on 018 -042 sizes; and defrost board for
time /temperature defrost function. All
units are equipped with a discharge
muffler to minimize gas pulsation in
heating mode.
Defrost Control Board (048 and 060)
— Incorporates a built -in 5- minute
MqC11.' Form, av , , n
•
compressor time delay, a defrost relay,
defrost timer, and low - voltage wire
leads. The defrost control is a time/
temperature initiation /termination
control which includes 3 field -
selectable time periods of 30, 50, and
90 minutes.
Weather - Protective Cabinet —
Steel is galvanized and coated with a
layer of zinc phosphate. A polyester
powder coating is then applied and
baked on, providing each unit with a
hard, smooth finish that will last for
many years.
All screws on cabinet exterior are
coated for a long - lasting rust - resistant,
quality appearance.
Unit Design — All units are equipped
with totally enclosed fan motors for
greater reliability under rain and snow
conditions. The large, wraparound coil
uses copper tubes and enhanced sine
wave aluminum fins and is designed
for optimum heat transfer during
heating and cooling. The vertical air
discharge carries the sound and air up
and away from adjacent patio areas
and foliage. Coil can be cleaned with a
common garden hose.
Model number nomenclature
38YKC 018 3
Electric Heat Pump
Nominal Capacity
018 — 18,000 Btuh
024 — 24,000 Btuh
030 — 30,000 Btuh
036 — 36,000 Btuh
042 — 42,000 Btuh
048 — 48,000 Btuh
060 — 60,000 Btuh
1
Series
c
External Service Valves — Both
service valves are brass, front seating
type with sweat connections. Each
valve has a service port for ease of
checking operating refrigerant
pressures. Valves are externally located
so refrigerant tube connections can be
made quickly and easily. A third
service port is located on the service
panel for ease of checking operating
suction pressure in the heating mode.
Warranty — Standard 1 -year
warranty on all parts, with an
additional 4 -year warranty on
compressor.
Packaging
Electrical
3 — 208/230 -1
•
0
•
•
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
Physical data
CERTIFICATE N0. FM 28768
CERTIFICATION OF
MANUFACTURING SITE
APPROVALS
ISO 9001
EN 29001
BS 5750 PART 1
ANSI /ASOC 091
,,, i, to:,,;,, -r UNIT SIZE r;,s:',K..v. ;.: -rl
;.MCtO18 =30
':7.
is %.';. 024 -30;. "R
;M: 030 -30. i;u':
;;' e 036.304.'.
:i:�:,•042- 30';4'-.!st:'
048- 30` „th,.:+? 060.30?,�N : ;1
Ply
OPERATING WEIGHT (Lb)
139
165
199
215
229
268 I 293
COMPRESSOR MFR
Tecumseh Recip
30
Copeland Recip
76
;- ;': i 042 :'.: , •'
30
Copeland Scroll
REFRIGERANT
Control
Charge (Lb)”
4.13
30
4.38
4.88
)
22
Piston
7.13
8.13
I
11.51
12.38
CONDENSER FAN
Alr Discharge
Air Qty (CFM)
Motor Rpm (60 Hz)
1900
1100
2400
825
I
Vertical
3100
2900
1100
3100
CONDENSER COIL
Face Area (Sq Ft)
8.79
1 10.99
12.17
1 18.25
1 12.17
I
15.21
18.25
CONNECTION (In. ID)
Vapor
Liquid
5/8 1
Swoat
3/4 1
3/8
7/8
REFRIGERANTTUBESt (In. OD)
Vapor
Liquid
5/8 1
3/4 1
3/8
7/8
1
1 -1/8
" The factory refrigerant charge is or 15 ft of Inter - connecting tubing. For tubing lengths other than 15 ft, consult Long -Line Application Guideline for
additional refrigerant requiremen s.
t Tube sizes are for runs up to 50 ft. For tube set over 50 ft, consult Long -Line Application Guideline.
NOTE: See unit Installation Instructions for proper installation.
• METERING DEVICE
,SItE' ; ".°
SERIES
OUTDOOR
PISTON
INDOOR
PISTON"
4.:;12',;!::•,%:018'.. .,
30
42
55
'' "1;'.'024' `. ,J
30
46
65
30
52
70
r,..r,;;;:e.:038...1..r'.∎
30
61
76
;- ;': i 042 :'.: , •'
30
63
80
i,, ,; r ' 048 ,,- .
30
70
88
1:1'„`:'.1+; 060, '.. ,,
30
78
98
Piston shipped with outdoor unit and must be installed in approved
indoor coil.
3
Electrical data
ii,�
• S)'f r,'
O�I.TDOOR;
AUNIT. t r
V -PH
OPER VOLTS"
COMPR
FAN FLA
MCA
60 °C
MIN
WIRE
SIZEt
75 °C
MIN
WIRE
SIZEt
60 °C
MAX
LENGTH
(Ft)$
75 °C
MAX
LENGTH
(F1)#
MAX FUSE ** OR
HACRTYPE CKT
$KR AMPS
Max
Min
LRA
RLA
p' ' 018=30;
208/230 -1
253
187
49.0
8.9
0.8
11.9
14
14
66
62
20
Wi.;024 -30:;
61.0
11.2
0.8
14.8
14
14
53
50
25
31,3030.330 i
84.0
14.4
0.9
19.0
14
14
41
39
30
itr0036430V
96.0
16.2
1.4
21.7
12
12
57
54
30
N.VI042- 301,;1 i
102.0
20.9
1.4
27.5
10
10
71
68
40
O5;::.;O48 -30'f.
129.0
28.7
1.4
37.3
8
8
82
78
60
rJ.:i080- 300.4:
169.0
31.1
1.4
40.3
8
8
78
74
60
Permissible limits of the voltage range at which the unl will operate satisfactorily. Operation outside these limits ma'y result in unit failure.
t If wire is applied at ambient greater than 30 °C (86 °F), consult Table 310-16 of the NEC (ANSI /NFPA 70).
The ampacity of non - metallic- sheathed cable (NM), trade name ROMEX, shall be that of 60 °C (140 °F) conductors per NEC (ANSI /NFPA 70)
Article 336.30.
If other than uncoated (non - plated), 60 or 75 °C (140 or 167 °F) Insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger
than 10 AWG) is used, consult applicable tables of the NEC (ANSI /NFPA 70).
# Length shown Is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 %.
•• Time -delay fuse.
NOTES:
1. Control circuit Is 24v on all units and requires external power source.
2. Copper wire must be used from service disconnect to unit,
3. All motors /compressors contain Internal overload protection.
FLA - Full Load Amps
HACR - Heating, Air Conditioning, Refrigeration
LRA - Locked Rotor Amps
MCA - Minimum Circuit Amps
RLA - Rated Load Amps
(i
JSE " OR
'YPE CKT
AMPS
?0
?5
30
30
i0
30
30
A 70)
t for larger
Dimensions
E
N
N
N
O
c
C
0
U
8
O .(1)
ft1 E
N 3
n
o —°
y
4)
(D 42 E
t'S N.
cc1Lo- E
• 0 co
4) • c c
O N O
C .O O E �.
•
co C E on C
C N 0 O
7 '0 o t
O C.0 o
v v c c o
▪ 0)E0
()a
,E Ca al
O
• E N N
N
• c N a. •
O O O 0
0 • O O 'O- a,
• r'00 =5
U (�S
O 0 m 0)
0 N E
• 0 • • c c
: o )
ul
• N cri et u)
0
Z
DIMENSIONS (In.)
Snow Stand
co
x
LL
r
a
N
x
N
N
x
0
N
UNIT DIMENSIONS
Z
N
CO
2
rn
.J
(�S
M
th
N
c
m
0)
0
N
a
LL
N
W
(b
(b
0
(9
N
0
N
0
4
()
0
0
�2 }:;:ir°.,,�: ?.`'.,._:•' "':ir.....; C(c:Tr.';L:�fis4:1`.5F 7; r. ataM:. c: rctu�: rmw: autaw. s' ix+ nuxst�l�titix :aY'CF:i'twv.f•�:,C07, -1414
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development
March 10, 2000
Paul Olsen
4101 B Place NW
Auburn Wa 98001
RE: Permit Status M99 -0092
17830 West Valley Hwy
Dear Mr Olsen:
Steve Lancaster, Director
In reviewing our current permit files, it appears that your permit to install a system heat pump
issued on May 25, 1999, has not received a final inspection as of the date of this letter by the City
of Tukwila Building Division.
Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the
building official under the provision of this code shall expire by limitation and become null and
void if the building or work authorized by such permit is not commenced within 180 days from
the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, if a final inspection is not called for within ten (10) business days from the
date of this letter, the Permit Center will close your file and the work completed to date will be
considered non - complying and not in conformance with the Uniform Building Code and /or
Mechanical Code.
Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection.
Thank you for your cooperation in this matter.
Sincerely,
ci
Bill Rambo
Permit Technician
Xc: Permit File No. M99 -0092
Dunne Griffin, Building Official
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670
Fax: 206.431.3665
c
Perm+ Qoovd. Ccpy
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M99 -0092 DATE:. 5 -4 -99
PROJECT NAME: HARTUNG GLASS COMPANY
XX Original Plan Submittal
Response to Incomplete Letter
Response to. Correction Letter # Revision # _ After Permit Is Issued,
DEPARTMENTS:
1
Building Division
Ala./ 5(0 r1
P blic Works
iv&g-,69._q4A--
Fir Prevention
G5.7 -�
Structural �...
�T
Plannivng Division X.
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 5 -6 -99
Complete
Incomplete n
Not Applicable
Comments:
TUES /THURS ROUTING: Please Route
No further Review Required
Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: (ten days)
Approved
Approved with Conditions
DUE DATE: 6 -3 -99
Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
CORRECTION DETERMINATION: DUE DATE:
Approved Approved with Conditions
Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
\PR•ROUT[.DOC
6/98
- 4EATING- /COOL'NG EQUIPMENT SCHEDULE
..
IC
?RAND NA
MODEL NJMBER
'+NFE36
GM
—i
HEATING
INPUT
F9t,
OUTPUT
(=t"hJ
NET COOLG
CAPACITY IN
03,4,
SEER
OR
EER
EFFICIENCY
OR
■ COP
OSA
CO
EGONO.
V/0
PICA
T10CP
WT.
2
C �L2R'�
TGARF: =R
FBa- -3
y'B�KCO�p -1
i3O0 -
- -
36�iO0
96 00®
11.5
-
1 208, 30 -1 -60
208 -I -60
32.0
21.1
S0
30
1281bs_
21S Ihs
DIFF., 6 "RD
(NEW)
DIFF., 8 "RD
(NEW)
NOTE: T as are c':ooramratico • only.
Please vet a :I orre,s"o at jot site.
x
DIFF., 6 "RD
(NEW)
8 "x8 ", 6 "RD CD 8"x8 6 "RD GD
(NEW) (NEW)
Eg
x
DIFF., 8 "RD
(NEW)
7
DIFF., 6 "RD
(NEW)
EXIST OUTDOOR
UNIT
PLACE NEXT TO EXISTING
OUTDOOR UNIT.
, HVAC FLAN
SCALE: 3/I6 " =1' -0"
Algot- 0092,
x
FOR
F. waNfCAL
t C RICAL
,innE,fm.;
j FILE COPY PERMITCEN - E
;,stand that the "Ian Check approvals are
TO error s an:, orissions and appro.. if
does net aut!IC. the 1110i,TOn of any
. ,)T (ramant;e Rec,pat t1i con-
....',copyo -a?pro . plans ac:'rr,Medued.
1i2M�
I i!
- ctnY S
w0600x :anee:ur:w o:eA:urc.
VICINTY MAP
PARCEL NO.: 362304 -9091
LEGAL DESCRIPTION:
LOT I OF RENTON SHORT PLAT NO. 346 -19
REC NO. 1901169001 SD PLAT DAF - POR
GL 2 4 NE 1/4 OF NW I/6 SD SEC LY ELY OF
WEST VALLEY ROAD 4 WLY OF FSE R/W 4
LY NLY OF LN WHC IS 156 FT N OF YEAS
AT R/A TI-40F 4 PLT N LN OF S ISO TH ST
LESS FOR CONY FOR SR 151.
FROPEikTY ADDRESS: 11150 SW VALLEY I-4WY.
TUKWILA, WASHINGTON
OWNER: NICK + PATRICIA ANN SCIOLA
TENANT: HARTUNG GLASS CO.
NVAC LEGEND NVAC NOTES
- 0 TIERMOSTAT OR 20ESTAT
- 60GLE DUCT WIIRAISITION
GELLING RADIATION DAMPER
.0. DIR45ER DR GRILLE
SFD STOKE FIE DAMPER
FDA-- FIRE DA`PER
o V.A. FAN
VOLLFE DAMPER
FLEXIBLE war SARA
—✓• E"OFE DETECTOR
I W 20E DA"F!' R
2012
NAr2TUNr GLASS COMPANY
118301.5 VALLEY HIGHWAY TUKWILA, WASHINGTON;
SCALE: 3,16 "•1' -0" DRAWN: WPD DATE: 04.21 -99
REVISION: DING. NO. 99016 -1
JOB NO
99016
UNIVERSAL POBOxb!4
AUGUR`:, Wd 98011
R SEA: (253 939.5901
REFRIGERATION
SEA: 839 -
i: 53) 922.3141 3141
s�roanmiro �uT VTe • I¢- wae:eaivaa cc+rt. ur.. wirtw m>a FN(. 0
: (2531135 -3
POCEIVED
CITY GF TUEWI
rNY
FOIE: - EQ1T INSTALLATION 006. 0001.5 TO
BE 0151TE FOR 26FE Olt
-ALL HV•C E09 TO BE LAB` -LED TO
THE SPACE SERVED.
- DUCTS TO BE SPFORsir • eA D EOi:GV
OINCe • :£RT• 12' MU HOJ2• 0'9AX
TORRAP, OR 6' HAX I.' 1,4 E' TE SSYDRT.
- 1HE16I05TAT TO HA. 00141 RIBA. APO
SE. DAT TIRE
- DJCT 0E11LA101 SwLL ffET REO1,
ROT.1414 OF 1. 199110ED AND
TAELE 14.5.
- 91'OKE DETECTOR'S! WALLED N FUN SPRY
AIR DUOS A9 FER 5.1 606 CF 1991.,
- OTOLORFnAN!RN: 5 R -A2 v 5ER LSEC
-&RP, LATERA S ^.95.0°E .0. T -BAN
GRID A'O HA0 CE1.045.
(
MOO Nla7