Loading...
HomeMy WebLinkAboutPermit M99-0122 - FASCINATION GRAPHICSM99 -0122 1130 Andover Pk. E. Fascination Graphics City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M99 -0122 Type: B -MECH Category: NRES Address: 1130 ANDOVER PK E Location: Parcel #: 262304 -9091 Contractor License No: PERFOHA150RT TENANT FASCINATION GRAPHICS 1130 ANDOVER PK EAST, TUKWILA, WA 98118 OWNER RICHARDS ERIC & CHERYL 1130 ANDOVER PARK W, TUKWILA WA 98168 CONTACT MATT WAKABAYASHI 7649 S 180, KENT WA 98032 CONTRACTOR PERFORMANCE HEATING 7649 ,S:180 ST, KENT WA 98032 Status: ISSUED Issued: 06/29/1999. Expires: 12 /26/1999. Phone: 425.251 -0356 Phone: 425 - 251 -0356 Phone: 425 251 -0356 *************** ik*********** k**************** k *k ** ********* * * * ** * * ** *** * * *** Permit Description: ADD 3 112 TON GA; PACK UNIT`ON.'_OUTSIDE ROOF. UMC Edition: 1997 Valuation: 1'4,000.00 Total Permit Fee.:. 46.50 * * * * ** k******************************.*.******* * * * * * * * * *. * * ** **.* *** * * ** * * * *** Permit Center uthorized Signature '.Date. I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to 'sign for and obtain this building permit. Signature: P67 Print Name : _OAR V" .ka laat .Va s+'t ( Date: Title: This permit shall become null and :void if the work >is not commenced within 180 days from the date of issuance, or if.i;he work is suspended or abandoned for a period of 180 days :from.tho.. last inspection. CITY OF TUKWILA Address: 1130 ANDOVER Pig: E Suite: Tenant: FASCINATION GRAPHICS :Type: O -MECH Parcel 4: M304-9091 • Permit No: M99 -0122 :status: ISSUED. Applied: 06/23/.1999 Issued: 06/29/1999 *•** *•** **•k k*'k** *•k•k** *•k*** ** * **•k *** *•k k *•k* * *•k** *•k** k *•k*k* **"k•k** k•k k*•k* k**** k * *•k Permit Conditions: 1. Readily accessible access to roof mounted equipment is required. 2`. Plumbing permits shall be obtained through the Seattle -King County Department of ;Public Health, Plumbing'wi•11 be inspected by that 'agency, inciuding all gas 'pip,ing '(296 - 4722). 3. Electrical permits ::hall be obtained through the Washington ,State Division of Labot and Industries and .:all' 'elec•tr?ical wort: will ;be inspe`cted by that, agency (248- 6630) . 4. No changes will be made to the `, plans unless approved by the Engineer and the Tukwila Build1ng-Division. 5. All permits, inspection records, and approved plans shall;be available at the .lob site prior to the start of `.any con- struc:tiott, '.These documents are to be maintained and avail able until final inspection ;approval is granted. All construction to be done An conformance with approved plans and requirements of the Uniform Building Code (1997, . Edition) as amended, Un i for °m Mechanical Code (1997 Ed i ti otj ) and Washington state Energy Code '(1997 Edition). 7. Validity of Permit, The ' issuance of: a permit or approval °; of plans, 'specifications, :and computations shall not be con -, strued to be a pe`rmit for or an approval :of, any violation ',`any of the provisions of the 'bu i 1 d ing code or of any other ordinance of the Jurisdiction. No permit presuming• ti give authority to violate or cancel the provisions of.: this' .. code shall be valid. L'. Manufacturers installation instructions required on for the building inspectors review.'` CITY OF,; UKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 R STAFF USE ONLY Project Number: Permit Number Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. Project Name/Tenant: a5cocc v� / CC�F�f yes no J Will there be storage of flammable /combustible hazardous material in the building? El o Attach list of materials and storage location on se 'wale 8 1/2 X lipaper indicating quuaalntities & Material Safety Data Sheets Va o o Construction: c 1 19-7 00c.) Tax Parcel Number: 2 Z 3LI -- q o `(f --CE O Site Address: /� b�`` y AviC�c� uer f'act C City State /Zip: h"u kw; t u� art Property Owner: 12, 9¢ /(i Phone: / Street Address: I 7,0 A/ Dvtti ilk_ tJ_ City State /Zip: T44. 4 t_4 Fax #: Contact Person: ,M e,q -- tf ak -a Jo. ya5'')/ 1 %d Phone: 2� _2 5 -�S/ Street Address: ..-7/ q s, t F0 h (- Stay 2 Fax #: Contractor: peri rvvi 4rite__ J 1`��G�1 ✓lG� �-- ��� �ULt���-i�' Phone: .., 4z5�25 1 --O � 56 Street Address: �t 4 q S, J (, -e(i City State /Zi 9" 1'i wad q�3Z Fax #: `E' 2- —Z5 ( °O 23'O Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: p e , U r C � e _ k IG Phone: ,r_2,5 __1 - / _6 3563. Street Address: .� 1- q s. rK /, - �� JCe�� Ci State/Zip: 2 Fax #: -• MISCELLANEOUS; PERMIT REVIEW; AND; APPROVAL REQUESTED: (TO BE FILLED`OUT BYAPPLICANT), .. _ Description of work to be done: A yes no J Will there be storage of flammable /combustible hazardous material in the building? El o Attach list of materials and storage location on se 'wale 8 1/2 X lipaper indicating quuaalntities & Material Safety Data Sheets 71 Above Ground Tanks Antennas /Satellite Dishes ■ Bulkhead /Docks _ l_) Commercial Reroof ❑ Demolition ❑ Fence -Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems in Temporary Facilities ❑ Tree Cutting APPLICANTtREQUESTTORMISCELLANEOUS PUBLIC:WORKS PERMITS i' ❑ Channelization /Striping in Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s : Est. quantity: gal Schedule: Moving Oversized Load /Hauling MONTHLY SERVICE.BILLINGS..T,Qi Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER; DEPOSIT /REFUND BILLING: Name: Phone: Address: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date ap cation at �r � i MISCPMT.DOC 7/11/96 Date pllcatlone3 .49 Ap on ken by: (I tlals) ALL MISCELLANEOUS PE= T APPLICATION$ MUST BE SUB ED WITH THE FOLLOWING: ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ° • a so $, ,R, • ` BUILLIINb'SItE P A'IV AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT A STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER A CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW ❑ Above Ground Tanks/Water.Tanks - Supported directly: upon. grade. exceeding: 5,000 gallons and:a ratio of height to.diamete'ror,,width which exceeds 2:1 'Submit checklist, No: ❑ Antennas /Satellite Dishes Submit checklist No:: ❑ • Awnings /Canopies - No signage . Bulkhead/Dock a 'Commercial.Reroof: Demolition Fences - Over 6 feet in Height. Submit checklist<::> No: Suubmit checklists <Submit`ohecklist.,- No: Land Altering /Grading/Preloads. Submit checklist No Loading Docks Mechanical'(Resldential & Commercial) ' - Miscellaneous Public"Works,Permits Commercial.Tenantlmprovemenf 7 :: Permit ` Suhmit'checklistrNo H' =1 `. Submit`ctecklist''<' No' ''M -i3; Residential only`; H;6 H -16'' Submit ahecklista o;::F Manufactured Housing:(RED.INSIGNIA ONLY).: 'Submitchecklist;:'< No :; M45 Moving; Oversized Load /Hauling Submit .checkiistr:INo:;. M= Parking Lots Subrnitchecklist No: ,: M -4' Residential•Reroof - Exempt with following exception: :If roof , structure.: to'be:repaired or replaced Residential,Building Permit : Submit checklist ". 'No: ',W6.< Retaining Walls - Over 4 feet in height •.Submit`checklist ,; 'No::. M -1 ❑ Temporary Facilities.. Submit checklist; ":: No: ❑ Temporary Pedestrian Protection/Exit Systems. Submit checklist No: ❑ Tree Cutting Submitch'ecklist ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other thantlie :owner,; reister©d"architecUenglneer, or`contractorlicensedi by the State of Washington, a notarized letter from the property owner authorizing the agent: tosubailt thisi permit application and obtain the permit will be required' as part of this submittal.: .. • I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW 'OR AUTHORIZED.'AG NT: / C e-',9 Date: �Z 3 92 :' Signature: (G� G' ��, .!'C Print name: In t G -- f Q. y Phone: t25 -2.5( _) 3 st Fax #: Address: / i.q ' -80 _tom- City /State /Zip: eC et-A- �l / , 7'8 D 3 Z MISCPMT'.'DO 7/11/96 - '1;- -r ;r,' 5•.e�•�.,,7•,r.`in."'�', ^e''>}'tY:' : i.� r Y' r . r. � 77.7.: ,,,767 A d'W;•t °tf Tv,>rr, r�r'F"�rf}.—r :`r^iFS�•. 4.�f� 1 k*A * ** * ** * ** *'kAt'A *A *+•k►�*A* .A'tit ** AA*A 4•. 1* *AAA*of*4k0A•k**A'7A*k*A•4kA* .:1 Y OF TUKWILA, WA 1- -" I G TRANSMIT kA**. 4A** ,4 *k *'4* *AA•'A *4 *A.A * *A *A* * * *ti *'** A** *A *•A•** *Ark4** *A•AkA * *A*IkA ** TRANSMIT Number: 89800093 Amount: 46.50 06/29/99 12.19 Payment Method: CHECK Notation: PERFORMANCE HEAT ]:nit: TLB Permit Na u Me9-0122 Type: E3 -MECH MECHANICAL PERMIT Parcel Nog 262304- 9091 Site Address w i. �1 30 ANDOVER PK E Total Fe“,: 46.50 This Payment 46.50 Total ALL. Pit 46.50 Balance: .00 1 A•/.4* •A *A:4 *A**i ** ** **A *A'k•A* **ok ** Alit* O*A'A&r *ytd�*A * *Ak **A * * * * *** *k* *.. Amount Account Code Description • • 0OO/345.030 PLAN CHECK NONRE.3 9.30 000/322.100 MECHANICAL •- NONRES 37.2(L' • • rt , 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 P.1,9jacki • vi. Typesivielltir: A dr ee s. lAb v I- Date c8ed: 5 PM) Special instructions: C22&C' Fx 4es, z 5 /-xetate41 Date a.m.' („,,,g :150 P.m. Requester kOjir- —A5 -03S-6 Phone: Approved per applicable codes. COMMENTS. Corrections required prior to approval. ic,--42..ecrio-Ar 1°6.2 /tom Afz- bpiodtcre" $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: . - , , , : • ' • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. - 24)114. 6300 Southcenter Blvd, #jO, Tukwila, 981 8 • (.06)43,1-3670 CITY OF TUKWILA BUILDING DIVISION - Project: rlitLair I 1 A L "'A it. Addr: s w S 6 IMIWO - pe f Inspec io 'ilifi. Ablri Date called: / AMR Special tructions: Date wanted: /7 7 -7' Requester. Phone: 43._c .... ii; 510 Corrections required prior to approval. Approved per applicable codes. COMMENTS: 1-7 Ce-4171 od-V/Aro CPI2 c/ "3" ‘2,9 ise c 4e-f-.,-)-7 eill 445 19a Inspector. Ada E •$4 .0 • REINSPECT! N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: Date: INSPECTION NO. 1.1 INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188A A _ (20)431 -3670 pea: } i' / a/S / ;Typ�•f I s•ect;, ,t _ Ad 7 s D #406 -m •Date called: 7// 1/ 2 , Special instructions: p < Date wanted: -' /��-'/ p.m.,. Requester: Phone� /J 5/-DE, pi,Approved per applicable codes. COMMENTS: 0 Corrections required prior to approval. Inspector:/' / Date: $47.00 REINSPECTION F[ ' EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date:. General Data `LE- cc,\( MODEL RATED VOLTS /PH /HZ A.R.I. RATINGS (COOLINGkD BTUH Indoor Air Flow (CFM) System Power (KW) EER /SEER (BTU/WATT -HR.) Noise Rating No. A.G.A. RATINGS (HEATING)® (High) Input BTUH Capacity BTUHOO AFUE Temp. Rise °F (Min. /Max.) (Low) Input BTUH Capacity BTUHOO AFUE /CSE Temp. Rise °F (Min. /Max.) Type of Gas® POWER CONNS. - V /PH /HZ Min. Brch. Cir. Ampacity Br. Cir. - Max. (Amps) Prot. Rtg. - Recmd. (Amps) COMPRESSOR No. Used Volts /PH /HZ R.L. Amps - L.R. Amps OUTDOOR COIL - TYPE Rows / F.P.I. Face Area (Sq. Ft.) Tube Size (in.) INDOOR COIL - TYPE Rows / F.P.I. Face Area (Sq. Ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) Duct Connections OUTDOOR FAN - TYPE No. Used / Dia, (in.) Type Drive / No. Speeds No. Motors - HP Motor Speed R,P.M. Volts /PH /HZ F.L. Amps - L.R. Amps INDOOR FAN - TYPE Dia. x Width (in.) No. Used Drive / Speeds (No.) No. Motors - HP Motor Speed R.P.M. Volts /PH /HZ F.L. Amps - L.R. Amps COMBUSTION FAN - TYPE Drive - Speeds (No.) Motor HP - Speed (RPM) Volts /PH /HZ F.L. Amps FILTER - FURNISHED? Type Recommended Min. Face Area-Lo (ft.) ®® REFRIGERANT Charge Ilbs. of R -22)e GAS PIPE SIZE (IN.) DIMENSIONS Crated (in.) Uncrated WEIGHT Shipping (Ibs.) / Net (Ibs.) See notes on page 14 YCC042F1MOB YCC042F3MOB YCC048FIMOB YCC048F3MOB 208-230/3/60 208-230/3/60 208- 230/1/60 208-230/3/60 42000 42000 46500 46500 1400 1400 1600 1600 4.79 4.42 5.23 4.89 8.85 / 10,00 9.50 / 10,00 8.90 / 10,00 8.90 / 10.00 8,0 8.0 8,0 8.0 100000 100000 100000 100000 80000 80000 80000 80000 78% 78% 78% 78% 45 / 75 45 / 75 30 / 60 30 / 60 80000 80000 80000 80000 64000 68000 64000 64000 18 %/76% 78 %/76% 78 %/76% 78 %/76% 45.75 45 - 75 30 - 60 30.60 NATURAL NATURAL NATURAL NATURAL 208 - 230/1/60 208 - 230/3/60 208 - 230/1/60 208-230/3/60 30,2 22 33 24.8 50 35 50 40 50 35 50 40 CLIMATUFFF" CLIMATUFF" CLIMATUFP" CLIMATUFP" 1 1 1 1 200. 230/1/80 200-230/3/60 200 - 230/1/60 200 - 230/3/80 20.6 -105 14 -101 21.7 -119 15.1 -101 PLATE FIN PLATE FIN PLATE FIN PLATE FIN 2/15 2/15 2/15 2/15 8,62 8.62 8.62 8.62 3/8 3/8 3/8 3/8 PLATE AN PLATE FIN PLATE FIN PLATE FIN 3/15 3/15 3/15 3/15 4.28 4.28 4.28 4.28 3/8 3/8 3/8 3/8 CAPILLARY CAPILLARY CAPILLARY CAPILLARY 3/4" FEMALE 3/4" FEMALE 3/4" FEMALE 3/4" FEMALE SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTUNE DRAWING PROPELLER PROPELLER PROPELLER PROPELLER 1/18 1/18 1/18 1 /18 DIRECT / 1 DIRECT / 1 DIRECT / 1 DIRECT / 1 1 - 1/5 1 - 1/5 1 - 1/5 1 - 1/5 1080 1080 1080 1080 230/1/60 230/1/80 230/1/60 230/1/60 1.6 -3.3 1,6 -3.3 1.6 -3.3 1.6 -3.3 CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL 10X9 10X9 10X10 10X10 1 1 1 1 DIRECT / 2 DIRECT / 2 DIRECT / 1 DIRECT / 1 1 -1 /3 1 -1 /3 1 - 3/4 1 - 3/4 1080 1080 1145 1145 200 - 230/1/60 200- 230/1/60 200- 230/1/60 200 - 230/1/60 2.8/2,2 -5.1 2.8/2.2 -5.1 4.3 -11.2 4,3 -11.2 CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL DIRECT -1 DIRECT -1 DIRECT -1 DIRECT -1 1/35 - 3480 1/35 - 3480 1/35 - 3480 1/35 - 3480 208-240/1/60 208- 240/1/80 208- 240/1/60 208- 240/1/60 0.8 0.6 0.8 0.6 NO NO NO NO THROWAWAY THROWAWAY THROWAWAY THROWAWAY 4.67 4.67 5.33 5.33 8 Ibs. 8 oz. 6 Ibs. 8 oz. 6,42 Ibs. 6.42 Ibs. 1/2" 1/2" 1/2" 1/2" HXWXD HXWXO HXWXD HXWXO 35 -1/4 X 38 X 64-5/8 35 -1/4 X 38 X 64-5/8 35.1/4 X 38 X 64-5/8 35 -1/4 X 38 X 64-5/8 SEE OUTLINE DIMING SEE OUTUNE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING RECEIVED 481 / 414 481 / 414 481 / 414 CITY OF TUKWISA/ 414 JUN 2 3 1999 m499, PERMIT CENTER 11 • Typical Field Wiring YCC -F Field Wiring Diagram PACKAGED CAS - ELECTRIC UNIT UNIT CONTROL BOX GROUND 4. I PH WIRE POWER POWER UNIT NOTE 1 • 4 761BLI COMMON 4741BK1 FAN 44AIYL1 COMPRESSOR 41AIBRI HEAT 7SAIR01 24V UNIT LOW VOLTAGE AREA 11 UDDDEI TYPICAL THERMOSTAT NOTES: 1. FUSED DISCONNECT SIZE. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH CODES. 2. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT AND HEATER NAMEPLATE, 3, LOW VOLTAGE WIRING TO BE 18 AWG MINIMUM CONDUCTOR. 4. SEE UNIT DIAGRAM FOR ELECTRICAL CONNECTION DETAILS. B. THE THERMOSTAT ON THE YCC UNIT MUST PROVIDE A "G" SIGNAL IN THE COOL- ING MODE ONLY. DURING THE HEATING MODE THE FAN W ILLBE ENERGIZED BY THE SYSTEM. INTER - COMPONENT WIRING 24V. . FACTORY LINE V WIRING LINE V.} WIRING WIRE COLOR DESIGNATION ABBR COLOR A88R COLOR BK BLACK PR PURPLE 8L BLUE RD RED BR BROWN WH WHITE OR GREEN YL YELLOW OR ORANGE ECONOMIZER ACCESSORY CONNECTIONS TO ECONOMIZER FACTORY PROVIDED IIELO INSTALLED WIRES till 7L1 I I L-6E— B--cl I L acrvu I L 47E1BK1 41100 — 47A1BN1 L 4401PR1 4- IAIYLI - 41A1001 7SAIRDI VOlTAO[WAREA TYP CAL 2 -STAGE TNERMOSTAT FIELD JUMP 1- 2- 3- 4 — 5- 7 — 8 — 9 — 10- 11 — 12 — 13- 14- 15- 16- 17 — 18 — 19- 20 — 21 — 22 — 23 — 24 — 25 — 26 — 27 — 28 — 29 — 30 — 31 — 32 — 33 — 34 — 35 — 36 — 37 — 38 — 39 — 40 — 41 — 42 — 43 44 — 45 — 46 — 47 — 48 — 49 — 50 — 51 — 24 Typical Field Wiring • Wiring Diagram for YCC018 ,024,030,036,042,048,060F1 Units CAUTION -NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150 VOLTS TO ATTENTION: NE CONVIENT PAS POUR LES INSTALLATIONS DE PLUS OE 1S0V. A TERRE. UNIT FACTORY WIRED FOR 230V SEE WIRING DIAGRAM NOTES FOR REQUIRED WIRING CHANGES WHEN INSTALLED ON A 208V POWER SUPPPLY. POWER SUPPLY PER LOCAL CODES SEE NAMEPLATE FOR LINE VOLTAGE. • m m 4A18K1 • 2A.B.C.DIBK) C� -2� BLACK • CC -1 IA.B.C.01R010II 3A.CIRD) 3BIRO) I8(RDI 0FL 20A(RDI 2B18K1 1 3 • 1CIRD) oI 21AIRD) 1 3 m WARNING HAZARDOUS VOLTAGE) DISCONNECT ALL ELECTRIC POWER BEFORE SERVICING. FAILURE TO DISCONNECT POWER SUPPLY BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK. VOLTAGE AVERT x SSEMENT DECONNE9TEZ TOUS LESS INTERRUPTEURS AVANT D EFFECTUER L ENTRETIEN. FAUTE DE DECONECTER LA SOURCE E4ECTRICUE AVANT D'EFFECTUER L ENTRAINER DES BLESSURES CORPORELLES SEVERES DU LA MORT PAR ELECTROCUTION. MPOR USE COPIPEER CONDDUCTOORnS ONLY TO PREVENT EQUIPMENT DAMAGE. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT ANY OTHER WIRING. 20AIR0)— C 28(8(4)H1 o 0 tare - FTBA 3CIRD) CR 201 BK1 35AIRD1 ON-3 ON-2 WHITE COM • ORANGE CH-70 1DIR0) C� 1 RED 230V. 296V. BLACK/R0 4-- L. C J7Af8RITC0 A 39A10R) m INSET A YELLOW ICF2 BROWN �1E0 PURPLE BLACK RED 4A(BK) C 7AI .R1 S 3AIRDI R BLACK 20(BK) H LOW FTBA CN -4 21AIRD) RED • TNS1 24 V. ACK/8L IOR) /'f7 3BAISRICTH MV 1F0045A(8K1 CFPIGN BR fORI � /47 C 0J�� 1GN D- 0 • 38J (Bt./ 36EjBL) CN-6 CV 1 MAIN 41818R) 35BIRD)CN- 14 35CIRD) 41AIBR) 41AIBR) 3SCIRDI TYPICAL _ROOM THERMOSTAT I R 47AIBK) J j - - - rf; J rJ 4 360180 Q 47A1 KI 0 FS 44A(YL1 48A(BKI C:1545B(6K) 44A)YL) 0 H 38E(BLI• 036F.E(BLI • H-26 „30C DM/ F -23 360.FI8L) OC7 -15, continued on next page From Dwg. 21D758911 Rev. 6 1 Typical Wiring Wiring Diagram for YCC018 ,024,030,036,042,048,060F1 Units INDOOR SECTION GNATION ABBR COLOR CONTROL BOX COLOR BK PURPLE BROWN —yon BLACK ears PR PURPLE «..on1 A ...e REEL BLUE RD RED ^ W ICN FPrH ION• is G o 0 g IDM w Fe. _m K vin PURPLE gie 03 CO < N hO• < IGRI .JJ c. w W (10 nn P7 Q T�_- 7A(OR) PURPLE 3C(RDI 20AIRD1 81BK)�C 28181(1 L�! N -14 47Xi8K) 46818K1 CN -15 46A1BK) 38(RDI limm BROWN RED • YELLOW • • •` BROWN - WHITE CN -2 °� ix JSCIRDI 1 /AWI 37A1BR1 no WW1 2D(BK) ORANGE C -7 m a u = 11 38A(BRI 38AIBR) 39AIBR1 36J(BL) RED C -1 bi 3:g F 4 4 ab H p ? IDIRD) TNSI BLACK /RD CN -3 35A(RDI 111 m m BLACK /8L CN -6 36818L1 m c W . 36C1BL1 v u (CR> n .1 • 36D,F(BLI II 42A1BR) CV IA,8,C,D(RDI 2A,B,C.D(BKI 3A,B,CIRD) 4A(BK), L " WYO !o ICR1 BLACK 44A(YL1 45AIBK) —4 I FD I P (GR) 0 m m Y CO N t 1". a 181g1818 R W G Y B L oII INSET @ FTBA(PURPLE 20A1RD1 I BLACK RED 2BIBK) NOTES: WIRE COLOR DES GNATION ABBR COLOR MBA COLOR BK BLACK PR PURPLE 81. BLUE RD RED BR BROWN WH WHITE CR GREEN YL YELLOW OR ORANGE, Q CONNECTIONS SHOWN ARE FOR A TYPICAL THERMOSTAT. SEE SCHEMATIC SUPPLIED WITH THERMOSTAT FOR PROPER CONNECTIONS.LOW VOLTAGE WIRING TO UNIT MAY BE NEC CLASS 2 AND MUST BE A MIN. OF 16 A.W.G. 2, MAXIMUM ADDITIONAL EXTERNAL LOAD (PILOT DUTY) BETWEEN B" AND "R" OF 0.5 AMPS, 24 VAC IS © AVAILABLE IN THE COOLING MODE ONLY. FOR 208 VOLT OPERATION MAKE THE FOLLOWING WIRING CHANGES: A: AT TNSI MOVE 10(RD) FROM RED WIRE AND CONNECT TO ORANGE WIRE. THE RED WIRE MUST BE RE- TERMINATED 70 AVOID ACCIDENTLY SHORTING. B: AT IDM MOVE 20AIRD) LEAD FORM FTBA -B TO YELLOW LEAD AT CF2. 4. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED IN THIS UNIT MUST BE REPLACED, REPLACE IT WITH APPLIANCE WIRING MATERIAL RATED AT 105 C. Q INDOOR BLOWER MOTOR CONNECTIONS SHOWN ARE FOR THE YC•024F1,- 036F1. - 042F1, AND -060F1 UNITS. FOR INDOOR BLOWER MOTOR CONNECTIONS FOR THE YC•018F1,- 030F1, AND -048F1 UNITS SEE INSETS A AND B. 11U01 r41 J g ' -UIZ4 MUM 11 ' T:Sf..1<.7.galiyl♦��� 1.3111.[0•" °,i:.X: TrILT •11111• X11 1♦ UI maamelanumiavumuummui Imo wow fin.::: r:■ VALI �1 I1E17 WPM LIMMIn:11111111111 ILLM 1>t2:11101=111I ta12:1V Ebf IN SCI I.TX •EMI I.. :t.trir E INF111 6iiti11e v 4.PI.71•111■- 11111a11 :11 L. '111111111=1111111.1Eil• C [.LI• 1I•:.1111•11111111•111MtA MEM Laid- IrML 11F11111 11371[ I`. air..10111111E ILE:1•! I.1• "Mall IEEMLIlIIL:•L.4.iL /11F- 1:4.1111 II From Dwg. 21D756911 Roy. 6 25 1 — 2 — 3 — 4 — 5 — 6 — 7 — e- 9 — 10- 11 — 12- 13- 14- 15- 16 — 17 18- 19- 20 — 21 — 22 — 23 24 — 25 — 26 — 27 — 28 — 29 — 30 — 31 — 32 — 33 — 34 — 35 — 38 — 37 — 38 — 39 — 40 — 41 — 42 — 43 — 44 — 45 — 46 47 — 48 — 49 — SO — 51 — 26 Typical Wiring Wiring Diagram for YCC036F3LOB, 036F3H0B ,042F3M0B4O48F3H0B4O60F3MOB UNIT FACTORY WIRED FOR 230V SEE WIRING DIAGRAM NOTES FOR REQUIRED WIRING CHANGES WHEN INSTALLED ON A 208V POWER SUPPPLY. POWER SUPPLY PER LOCAL CODES SEE NAMEPLATE FOR LINE VOLTAGE. • • . ! °m m m u -.7 i N rn Zi 2A,B,C,D(8K) QI WARN ING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER BEFORE SERVICING. FAILURE TO DISCONNECT POWER SUPPLY BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK. VOLTAGE AVERT xSSEMENT DECONNE9TEZ TOUS LE INTERRUPTEURS AVANT 0 EFFECTUER L ENTRETIEN. FAUTE DE OECONECTER LA SOURCE EIrECTRICUE AVANT D'EFFECTUER L ENTRAINER DES BLESSURES CORPORELLES SEVERES DU LA MORT PAR ELECTROCUTION. AIIMPORTANT USE CoPPER CONDUCTORS ONLY TO PREVENT EQUIPMENT DAMAGE. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT ANY OTHER WIRING. 4A(BK),BLACK INSET A 20A(RD) YELLOW 17(CF2 BROWN B 8 I PURPLE HI o C BLACK 2B18K1 0 RED LOWFTBA 4AIBK) 3 CC -1 IA,B,C,O,EIRDI 00.03A,B,EIRDI ♦- 0 1E1RD1 ( BLACK CCH BLACK U 3EIRD) 38(RDI CFI F 18(RDI 000 20AIRD1 28(BK) 1 3 • SAIBL) 02 3AIRD) 1 BLACK PURPLE BROWN YELLOW 0110 BROWN 20AIRD1 I_IB PURP ICIRD1 t , Hl_ 21AIRD) f'� 2C(BK) CPR IOL 28(8K1 HI C BLACK L 0 RED FTBA 21AIRDI C :4 RED 2CIBK) CN -5 BLACK 3SAIROI CN-3 2018K) C � 2 WHITE COM CN-7N•� ORANGE 206V. 1DIRD1 C Y 1 RED 230V. BLACK/RD cPS 37Al8RITC0 38AIBRIFL 39AIBRI rc N0. TNS 1 CN-6 B ACK/BL (GR) fi 368 1: 1 24 V 39A(BR) 3SBIROICN_14 35C(RD1r -- 41AIBR) TN MV FFDD 0 5A1BK1 CFP IGN IGRI CORD I�DORANGEO rh Col 36JtBL1 36E(BLI 41818R 41A1BR) 1 T GV g. TYPICAL ROOM THERMOSTAT 44A1YL1 368(BL) 35CIRDI 47AIBKIFS 36Et8L). 036E , F l BL 1• H-26 46A16K1 CN♦15 468(6K)0003 6C,0(BL).F -23 44A(YL) ,r1, 360,F(BL).CC -14, 17 continued on next page From Dwg. 21D756981 Rev. 5 Typical Wiring Wiring Diagram for YCC036F3LOB, 036F3H0B ,042F3M0B4O48F3H0B4O60F3MOB INDOOR SECTION CONTROL BOX HEATER SECTION OUTDOOR SECTION - - MV FP ION IGN TH PR ' YELLOW-I BROWN j PBLACK BLACK �/ RED 1EIRDICDBLACK - CN-10 3E I RD 1 BUCK RO ♦nVS tllAlak 1_ I urm , __ A 8R �' J CN m u N CFM G W ¢ z • N -4 mm m N ♦n --- < PS — YL YELLOW (GR) m mm .( n WWia a v VP) W 2mm — so. nn FT PURPLE-AEF 20A(RDI- BLAC K 2B18K) BA J PURPLE 3B(RD) OD BROWN RED '• CN -2 YELLOW BROWN CN -14 35BIRDI 47AIBK) 488(BK) CN -15 48A1-K) WHITE 20(8K) o 0 ORANGE CN -7 °o cr o z - I RED CN -1 N N sclROl ^ 4:11 ID(RD) TNS 1 RD'335ACRD1 b1 31 F 11 31 H 37AIBR) •(L1Tr°I°T(• J581RD) q q q IIBLACK BLACKJBLCN- C36B18L) m m m m JBAIBRI 38A(BR) FL JGA(BRI 36JIBL) 42A(BRI CV 36C(8L) - o LT. - I GR I s: n n v 38D,F(BL) IA,B,C,D,EIRD1 2A,B,C,DIBKI • IN 3A,B,E(RD) 4A(BK), BLACK SAIBLI — 44AIYLI IGR) `WA= l>1 (OR) ( 1 45A(BK) -4 1 a° m m r m nnlnnn - nnnlI nnl�nnoI R W G Y B La FO IP IURPLE FTBA 20AIRDI BLACK RED -Q 2BIBK) NOTE THREE PHASE MOTOR (SI FACTORY SUPPLIED IN THIS EQUIPMENT, PROTECTED UNDER PRIMARY SINGLE -PHASE CONDITIONS WIRE COLOR DESIGNATION ASIR COLOR ABQR COLOR 8K BLACK PR PURPLE 8L BLUE RO RED 8R BROWN WM WHITE CA GREEN YL YELLOW OR ORANGF. NOTES: CONNECTIONS SHOWN ARE FOR A TYPICAL THERMOSTAT. SEE SCHEMATIC SUPPLIED WITH THERMOSTAT FOR PROPER CONNECTIONS.LOW VOLTAGE WIRING TO UNIT MAY BE NEC CLASS 2 AND MUST BE A MIN. OF 18 A.W.C. 2. MAXIMUM ADDITIONAL EXTERNAL LOAD (PILOT DUTY) BETWEEN 8" AND "R' OF 0.5 AMPS, 24 VAC IS AVAILABLE IN THE COOLING MODE ONLY. Q FOR 208 VOLT OPERATION MAKE THE FOLLOWING WIRING CHANGES: A: AT TNSI MOVE 1D(RDI FROM RED WIRE AND CONNECT TO ORANGE WIRE. THE RED WIRE MUST BE RE- TERMINATED TO AVOID ACCIDENTLY SHORTING. 8: AT IDM MOVE 20A(RDI LEAD FROM FTBA-8 TO YELLOW LEAD AT CF2. a IF ANY OF THE ORIGINAL WIRE AS SUPPLIED IN THIS UNIT MUST BE REPLACED, REPLACE IT WITH APPLIANCE WIRING MATERIAL RATED AT 105' C. ® INDOOR BLOWER MOTOR CONNECTIONS SHOWN ARE FOR THE YCC038F3, - 042F3, AND -080F3 UNITS. FOR INDOOR BLOWER MOTOR CONNECTIONS FOR THE YCC048F3 UNIT SEE INSET A AND B. DEVICE DESCRIPTION LINE CC COMPRESSOR CONTACTOR COIL 45 CCM CRANKCASE HEATER CFI OUTDOOR FAN CAPACITOR 0 CF2 INDOOR MOTOR CAPACITOR CN CONNECTOR OR WIRE NUT CFM CO0MMOUSTION fAN MOTOR CPR COMPRESSOR 22 21 15 f INDOOR FAN RELAY COIL FD FL AIK DETECT 42 FL FUS €ABLE LINK FLS FAN LIMIT IT H IF T KENIIIIIMI CIZS>IIIL7 • L ItflL IMMUZi LIS•f11■ QIIii%.11i.:•::- •I•)■Lf4ni•L EAFIr ilEi1iL1111111! �lEriLOILL:LALL351 t UM From Dwg. 21D756961 Rev. 5 27 Typical Wiring Wiring Diagram for YCC036F4HOB,YCC048F4HOB, YCC060F4MOB, YCC036FWHOB ,YCC048FWHOB,YCCO6OFWMOB 1 — 2- 3 — 4 — 5 — 6 — 7 — POWER SUPPLY PER LOCAL CODES SEE NAMEPLATE FOR LINE VOLTAGE 8 9 — , 10- 11 — 12- 13 — 14 — 15- 16 17- 18 — 19- 20-- 21 — 22 — 23 — 24 — 25 — 26 — 27 — 28 — 29 — 30 — 31 — 32 — 33-- 34 — 35 — 36 — 37 — 38 — 39 — 40 — 41 — 42 — 43 — 44 — 45 — 46 — 47 — 46 — 49 — 50 — 51 — 28 • • a m ry A. CC -2 2A,B,C,DIBK10.1 Fl Lt WARNING HAZARDOUS VOLTAGE) DISCONNECT ALL ELECTRIC POWER BEFORE SERVICING. FAILURE TO DISCONNECT POWER SUPPLY BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK. th VOLTAGE AVERT I SSEMENT DECONNECTEZ TOUS LES INTERRUPTEURS AVANT D'EFFECTUER L ENTRETIEN. FAUTE DE DECONECTER LA SOURCE ELECTRICUE AVANT D'EFFECTUER L'ENTRAINER DES BLESSURES CORPORELLES SEVERES DU LA MORT PAR ELECTROCUTION. USE COPPER IIPMPORTAN ONLY TO PREVENT ECUIPMENT DAMAGE. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT ANY OTHER WIRING. 4AIBK) BLACK INSET A 20AIRD) HI 0 c 2B(BKI 0 O LOW TBA • CC -1 IA,B,C,D,EIRD10110 3A,B,E(RO) 1EIRD)BLACK CCH BLACK° 3E(RDI 18(RD) F 3 28(8K) • C1r 7 RED 600V 2CIBKI C1 r8 BLACK/RD 460V IC(RDI CN -11 BLUE 38(RD 4AIBK) 3 5A(BLI c 3AIRDI 01 BLACK PURPLE CFI BROWN F0 20AIRD1 2OAIR01 ig? BROWN 2818K) HI c BLACK 0 RED YELLOW LOW FTBA Q INSET C CN 7W RED 600V TNS2 CN -12 H CN -4 5 '-"Y'I BLACK • 11AIR010110 21AIRD) RED • I ,2C(BK) O BLACK /RD 460V 1 1 3 230 V. 1C(RD) FU1 BLUE S O TNS2L4- CN -2 20(BK) • RED ID(RD) C � 1 RED 35AIRD) C1 -3 BLACK/RD BLACK CN- : 12AIBK) 12A(BK) C115 BLACK TNS1 24 V. BLACK /BL CN -6 (GR) 388 C(BL1 C 37A(BRlTCO 38AIBR! FL 39AIBR) 39A(BRI rS No. 01 C FD 045A(BKI (GRI r TH W 7 FP ION BROWN 42A(BRI CV 1 WIN GND I GN D ORANGE O COM 36J(BL) 3flE(BLI 4IBIBRI P 358(RDICN_ 1435C(RDI l-- 41AIBRI 41AIBRI I i 47AIBKI F HEAT I J I HEAT W1 F J ON 44AIYLI I IBC J I TYPICAL ROOM THERMOSTAT r' 14 36818L) 35CIRDI 47A(BK) 0 36E(BL10 36E,F(BLI •H 27 S 48AIBK) CNIT 15 46818KIej-10 6C.D(BL).F 21 44AIYL) cc> 38D,F(BL1 CC -13. 18 continued on next page From Dwg. 21D756962 Rev. 4 • • • Typical Wiring Wiring Diagram for YCC036F4HOB,YCC048F4HOB, YCC060F4MOB, YCC036FWHOB ,YCC048FWHOB,YCCO6OFWMOB INSET B FTBA O BLACK -(J I RED -11 NOTES: n1 CONNECTIONS SHOWN ARE FOR A TYPICAL THERMOSTAT, SEE SCHEMATIC SUPPLIED WITH THERMOSTAT FOR PROPER CONNECTIONS.LOW VOLTAGE WIRING TO UNIT MAY BE NEC CLASS 2 AND MUST BE A MIN, OF 18 A.W.G. 2. MAXIMUM ADDITIONAL EXTERNAL LOAD (PILOT DUTY) BETWEEN "8" AND "R" OF 0.5 AMPS, 24 VAC IS AVAILABLE IN THE COOLING MODE ONLY. © IF ANY OF THE ORIGINAL WIRE AS SUPPLIED IN THIS UNIT MUST BE REPLACED, REPLACE IT WITH APPLIANCE WIRING MATERIAL RATED AT 105 C. Q INDOOR BLOWER MOTOR CONNECTIONS SHOWN ARE FOR THE YCC038F4 AND -060F4 UNITS. FOR INDOOR BLOWER MOTOR CONNECTIONS FOR THE YCC048F4 UNIT SEE INSET A AND B. ® THE TNS2 (CFM TRANSFORMER) FUSES INDICATED IN INSET C AND D DO NOT APPLY TO ALL MODELS. IC 12 •111.1:1••1 11•1:r_rIr•P.1 Gl'1-L•;C01•]1[ :)•/11:];1CI•I11.1:1• 1111111 I iIIL;I.119;11!1311 •:11■C•A9?r1:14111140111111111 t- 1:1.1 :11f :)•111C�11 "AMMr Walf01- r'T:•1>!11111N1� THREE PHASE E MOTOR (S) FACTORY SUPPLIED IN THIS EQUIPMENT, PROTECTED UNDER PRIMARY SINGLE -PHASE CONDITIONS C'ANK A H A OUTDOOR FAN CAPACITOR INDOOR MOTOR CAPACITOR 1114r.li r.)x4t.T 1,1-arli -141 111111•11111 niigr)s a• :>>FT 11114WVm40i111.11111111111a1111 LAM • 0' FUSEABLE LINK FAN LIMIT SWITCH IFS & TCOI FAN SWITCH FAN TERMINAL 9 OCK MN 1:UM 11111113M11013141DTWCI 1; UMW 11lt11M4'r`,TT1111•Y1t11[7! r I r.(JIi a :C1:1�Et� .. . r • . - -.. E I 1.1301111107';U:i101:141.61•11.1111 �[d•T iT;i•]1�L• ;�_•i:7T'F�4.]:L4J♦E�E From Dwg. 21D756962 Rev. 4 29 CONTROL BOX - - HEATER SECTION YELLOW BROWN BLACK RED ICN ION W FP TH �0 CN -9 r 1E(RD)• BLACK IL I i ": �'"s __ to Y m CN- x m 3J:(R01.1BLACK - CN -4 o mm._ m m r +n 35B(RD) .-- r.NO, n S P - m m m y ow BLACKCN-12 I1A(RD) NWI O' 01010 **n nn B _ RCN- 1S2AIBK1 INSET D Q ® ® T. 2 I-BLUE ' BLACK /RD RED CN -7 m m .- i N mJ Q FTBA C 47A(BK PURPLE BLACK 1st 38(RD) BROWN 2B(BK) CN -14 48B(BK) CN -15 YELLOW , y BROWN RED-fo 20AIRD) ° 0 - - z i i RED CN -2 `r 35CIRD) m •um 37AIBR1 TM (MOM 2D1BK1 1m1 '� `r RED CN -1 1DIRD1 01 36 F q O • L• =] 38A(BRI 38AIBR1 FL 39AIBR) 36JIBLI TNS1 CN -; 368(BL) - IIJ6CIBL) - ,CN -3(OR) m m m m 35AIRD) m o m 35BIRD1 Y n m i n n ° 38D,F(BLI 42A1BR) GV 1A,B,C,D,E(RDI 2A,B,C,DIBK1 3A,B,EfR01 eRCMN ma 1:j_ BLACK) SAIBLI - 44A(YL) IGAI FD (GA) Q ii-' 45A(1310--0 J I ) 1 °m CO m r m n ^ n Y < < m 1fl ^},10 R W G Y B INSET B FTBA O BLACK -(J I RED -11 NOTES: n1 CONNECTIONS SHOWN ARE FOR A TYPICAL THERMOSTAT, SEE SCHEMATIC SUPPLIED WITH THERMOSTAT FOR PROPER CONNECTIONS.LOW VOLTAGE WIRING TO UNIT MAY BE NEC CLASS 2 AND MUST BE A MIN, OF 18 A.W.G. 2. MAXIMUM ADDITIONAL EXTERNAL LOAD (PILOT DUTY) BETWEEN "8" AND "R" OF 0.5 AMPS, 24 VAC IS AVAILABLE IN THE COOLING MODE ONLY. © IF ANY OF THE ORIGINAL WIRE AS SUPPLIED IN THIS UNIT MUST BE REPLACED, REPLACE IT WITH APPLIANCE WIRING MATERIAL RATED AT 105 C. Q INDOOR BLOWER MOTOR CONNECTIONS SHOWN ARE FOR THE YCC038F4 AND -060F4 UNITS. FOR INDOOR BLOWER MOTOR CONNECTIONS FOR THE YCC048F4 UNIT SEE INSET A AND B. ® THE TNS2 (CFM TRANSFORMER) FUSES INDICATED IN INSET C AND D DO NOT APPLY TO ALL MODELS. IC 12 •111.1:1••1 11•1:r_rIr•P.1 Gl'1-L•;C01•]1[ :)•/11:];1CI•I11.1:1• 1111111 I iIIL;I.119;11!1311 •:11■C•A9?r1:14111140111111111 t- 1:1.1 :11f :)•111C�11 "AMMr Walf01- r'T:•1>!11111N1� THREE PHASE E MOTOR (S) FACTORY SUPPLIED IN THIS EQUIPMENT, PROTECTED UNDER PRIMARY SINGLE -PHASE CONDITIONS C'ANK A H A OUTDOOR FAN CAPACITOR INDOOR MOTOR CAPACITOR 1114r.li r.)x4t.T 1,1-arli -141 111111•11111 niigr)s a• :>>FT 11114WVm40i111.11111111111a1111 LAM • 0' FUSEABLE LINK FAN LIMIT SWITCH IFS & TCOI FAN SWITCH FAN TERMINAL 9 OCK MN 1:UM 11111113M11013141DTWCI 1; UMW 11lt11M4'r`,TT1111•Y1t11[7! r I r.(JIi a :C1:1�Et� .. . r • . - -.. E I 1.1301111107';U:i101:141.61•11.1111 �[d•T iT;i•]1�L• ;�_•i:7T'F�4.]:L4J♦E�E From Dwg. 21D756962 Rev. 4 29 • • • CONTROL BOX ACCESS PANEL Dimensional Data YCC018 -060F Outline — Front (ALL DIMENSIONS ARE IN INCHES) D HOLE FOR 1/2" CONDUIT (UNIT CONTROL WIRES) 1" DIAMETER K. O. FOR 1/2 N.P.T. CAS CONNECTION AS VALVE ACCESS ONDENSER COIL CONDENSER COIL IN THIS AREA ONLY ON YCC042F -M, YCC04EF -M C MODEL A B C 0 E F YCC018/021F L YCC030F1 55.1/4 ME 25-3/14 12.15/14 34.3/4 KNOCKOUTS FOR 1/2'A1e 1•CpoIiT; • ,, ' YCC030FM1 YCC034FL/FM 44.1/4 34 213jiS 12.14/14 38.3/4 K1100mUTS FOR 3 /4•MCt•1 /4• /Tr ^^� Y000FH Y00042FM YCC048F-M 423/4 _. - -30 ...— •t-'3 IS -- I . . s ' #-+an - • ' •• r . :mg _ .' . 13 10100eUTS FOR 3 /4•AOt•1(4' � YCC048FM YCC080F•M 84-5/18 .._ .: »�aA. ;:, h^ t7t1iIN ... 10100pYTSK113/4'NC •li s: • ' • C (i Dimensional Data 1... and Weights YCC018 -060F Outline - Rear (ALL DIMENSIONS ARE IN INCHES) EVAPORATOR COIL & BLOWER PANEL K 'g HORIZONTAL SUPPLY OPENING DOWNFLO SUPPLY OPENING HORIZONTAL RETURN OPENING APPEARANCE SURFACE OF SUPPLY & RETURN PANEL SECT. X -X TYPICAL CROSS SECTION OF SUPPLY & RETURN PERIMETER FLANGES L k M D !HENS I ONAL SURFACE ISEE TABLEI 2- 1� DIA. ENTRY FOR 1/2 N.P.T. GAS CONNECTION CONDENSATE DRAIN FOR 3 \4" FEMALE NPT DOWNFLOW RETURN OPENING SECT Y -Y TYPICAL CROSS SECTION OF DOWNFLOW SUPPLY & RETURN PERIMETER FLANGES CABINET MODEL CORNER WEIGHT 118E1 UNIT WEIGHT 1NETLBS) A B C D E F G H J K L M N P Wt W4 A YCC018F1 68.3 61.7 84 92.9 307 55.1/4 36 25.3/16 18.9/16 11.1/18 6.9/18 6.13/16 17 215/16 25 17.1/2 10 3 4-7/18 YCCO201 69.4 60.0 85 99.6 314 YCC030F1 70.5 81.4 87 99.8 319 B YCC036FI. 84.06 68.06 92.1 113.7 358 55.1/4 38 29.3/18 18.9/16 111/18 6.9/16 6.13/18 17 20.3/4 25.13/16 174/2 10 3 4.7/16 YCCO3c6.M 78.3 68.3 95.6 109.7 352 19-3/4 24-13/16 Y00036F -M 88 67.8 93.2 115.13 384 C Y00036F -H 90.3 73.8 101 123.7 389 82.3/4 38 233/16 139/18 11.1/18 6-9/16 11.1/8 17 133/4 28.1/4 17.1/2 10 3 33/4 YCC042F -M 103.7 88.7 96.8 122.6 412 133/4 28.1/4 YCOIM8F.M 104.8 84.8 102.2 126.4 418 19-3 4 28-1 4 D YCC048F4i 123.8 104.8 132.5 157 518 64-5/16 45 33.3/8 211/18 15-1/16 4-15/16 31/8 21.15/16 26 291/2 20 14 3-1/2 8-5/16 YC0960F -M 135.4 109.8 137.3 189.3 552 25 294/2 From Dwg. 2113661690 Rev. 1 38 'P opera f PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M99 -0122 DATE 6 -23 -99 PROJECT NAME: FASCINATION GRAPHICS X Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: � 1 Bivision I �I FireN Prevention Public Works n Structural I Planning Division Permit Coordinator • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete .c Comments: Incomplete DUE DATE: 6 -24 -99 Not Applicable TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions No further Review Required ri DATE: DUE DATE 7 -22 -99 Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions ri Not Approved (attach comments) E REVIEWER'S INITIALS: DATE: VRROUTE.DOC 5/99 JUN 29 '99 12:06 Ti Post-le Pax Note 7671 Dal° Paltee T° 140f IA/ From NMI tei Co./Dept. Co, Phone N Phone a Fax# ub ion,...lot Fax Cl) 4 011) • WI 0 CO U E-I 0 01 Z C4is.".■"4. 1.4 CO 0 U al• 61 0'1 •*--- 1:14-■-■ 4 4 xv cN 41 ral 0 H 4.11i Ci H E.-1 CD O g ce 0 I-1 > cd Z 4*Ln E-I al Z r-i 4 . co 0 41 = en cr3 14 ryl E-4 P 4 to 0 4 (o H Cs. 0 42 E., co El 0 DN ri4 I ril C.) 0 Ch cd 0 IX ai > FA U 1-1 i co ✓ i 4 E-1 t ca ci) E-I 0 O Z ri Ci 0 l It+ CNI 44 1-1 C/') LA • 0 C.) Ca. La ko 0 Gil 04 r- b4 • P.1/1 • , . • ' • " ••, .• • . . . . new mechanical unit ENGINEERS NORTHWEST, INC. 6869 WOODLAWN AVE. N.E. SEATn..E, WASHINGTON 98115 A-SCIN 47 1130 ANC.)Okdok- ENGINEERS NW KEj , L f P R '4 VI ,. ) '. , ,, 1. (:) . ,, , :: - ' ‘: 9 ENG Li ,.. , 5 3 A. -•• Cl 10 /". 1 4C■2 ERMIT , fr. • J - DWN!. JOB NO: 00- 0 4, co smam ENTER / section a HVAG EQUIPMENT SCHEDULE MARK MFR./MODEL AREA SERVED �� GFM SP{ MI N, 05A �COOLl MATINS Ma/OUTPUT SYSTEM ELECTRICAL ELECTRICAL t E16HT TOTAL NOISE t RPTIN6 ECONOMIZER TOTAL D. EER IPLV MCA stu I �° = n+ , 11 Los m RTU-I TRNE /YC.GO47 3403 QFICE AREA 35 1400053 1500 42P00 WO 100 'b¢ 4.42 203-2301 3 22 414 80 NO FLOOR BUILDING ELEVATION SCALE: I /4" = I' -0" LEGAL DESCRIPTION I. ALL RECTANGULAR DUCTS ARE INSULATED WITH I" LINER ( OUTDOOR 2 "), AND ROUND DUCTS WRAPPED WITH R -3 WITHIN DRAWL SPACE AREA. UMC 601.1 (Table 6 -D) 2. ALL DUCTS ARE SECURELY FASTENED, HUNG OR SUPPORTED. UMC 603 4 WSEC 1415.1 Table 14 -5. 3. PHAG WILL INSTALL AMBER/BOOTH COMPANY VIBRATION ISOLATORS OF TYPE RVD -I -G INSTALLED, BETWEEN MECHANICAL EQUIPMENT AND METAL DUCTS. UMC 601.8 5. WHEN USED TO CONTROL 130TH COMFORT HEATING AND COOLING, ZONE THERMOSTATIC CONTROLS SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 DEG. FWITHIN THE SUPPLY OF HEATING 4 COOLING ENERGY TO THE ZONE 15 SHUT OFF OR REDUCED TO A MINIMUM. W5ECI4I2.2 HVA& SYSTEMS -MALL BE Fol/IPPEP WITH AUTOMATIC CONTROLS WITH SETBACK CAPABILITY, THE CONTROLS SHALL HAVE A MINIMUM 1 -DAY CLOCK AND BE CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK, NiSEC 1412.4 b. ALL ELECTRICAL WIRING WILL BE PONE BY E.C, 7, ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS OF MORE THAN 50 VOLTS SHALL HAVE A POSITIVE MEANS OF DISCONNEGT',ADJACENT TO AND IN SIGHT FROM THE EQUIPMENT SERVED A 120 -VOLT SERVICE OUTLET SHALL BE PROVIDED 4 LOCATED WITHIN 25 FT. OF THE ROOFTOP UNITS AND OUTDOOR UNITS FOR SERVICE AND MAINTENACE PURPOSES. UMG 309.1 10. THERMOSTAT LOCATIONS AND SCHEMATIC, TECHNICIAN TO VERIFY 5E5T LOCATION BASED ON EXISTING WIRING AND CONDUIT RUNS. REVIEW W/ PHA& ENGINEER BEFORE SELECTING FINAL LOCATION FOR NEW THERMOSTAT AND HUMIDISTAT. II, G0144EGT NEW ROOFTOP UNITS TO EXISTING MEDIUM PRESSURE GAS PIPING ON ROOF. TECHNICIAN TO VERIFY THAT EXISTING REGULATOR PRESSURE SETTINGS ARE COMPATIBLE WITH CHAS VALVES IN NEW UNITS. 100 OFM SHOEMAKER 100 MA TYP APN: 262304-10 BEG 5E COR SE 1 /4TH OF SE f/4 N 81 -44 -08 W 166.46 FT TH N OI -41 -2y E 102.16 FT TO TPOB TH N 15 -12 -31 W 253 FT TO E LN OF 5T AS CONV AUD FLIt 6375442 TH N OI -47 -29 E III FT TH 5 88 -12 -31 E 253 FT TH S 01-41-2 , 1 W III FT TO TPOB 300 CFM SNoEnAK02. OAR FLOOR WA GRILLE TO SERVE 1ST FL 12"4 DN TO FIRST FLOOR RTU -I HVAG FIRST FLOOR SCALE: 1/4" = i' -O" 150 GFM 70 CFM 12 "m 80 CFM IC FILE COPY — COLUMN 8 "m SHOEMAKER 105P, TYP HVAG SECOND FLOOR SCALE: 1/4" _ I' -0" ,-10 "m 200 CFM I understand that the Plan Che& RCP Urals are ublect!n errors add omrsaions and approval of ; ,tars does Rol aathnr Qe the vfoiation of anv rf locked Corte ui ordinance Recent of con- +.ryetor copy of 4pproved plans 4cKoowl edged .4 - A) Ltv 2q' Date Permit Mtqc14)1 iT PEWIT coa cHANICAL )EkISLECM 0 pLUM$!NG SHOEMAKER 100 MA 200 GFM, TYP ti T3S RECEIVED CITY OF N1(WIL4 UN 231999 W \/ V ! O l l z DATE: 6/18/99 DRAM: MW ENOR: ON APPVD: 6N JOB NUMBER: 385 - 1D M -I PERMIT CENTER SHEET I OF I M 00 -d •�