Loading...
HomeMy WebLinkAboutPermit M99-0158 - PACIFIC VIEW OFFICE PARK - BUILDING Cue":'. "�,... ,. >•rri fix,.......'.' "T`. .... M99 -0158 12101 Tukwila Int'1 Blvd. Pacific View Office Park —Bldg. C City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M99 -0158 Type: B -MECH Category: NRES Address: 12101 TUKWILA INTERNATIONAL BL Location: Parcel #: 092304 -9309 Contractor License No: PARROMI081J9 Status: ISSUED Issued: 01/24/2000 Expires: 07/22/2000 TENANT PACIFIC VIEW OFFICE PARK -BLDG C 12421 PACIFIC HY S, TUKWILA, WA 98168 OWNER NAKKERUD LIVING TRUST C/O STRATTON ELISE, 17060 21ST AVE SW, SEATTLE WA 98166 CONTACT MICK JORDON Phone: 208- 772 -5165 6600 N GOVERNMENT WY, COEUR D ALENE ID 83815 CONTRACTOR PARROTT MECHANICAL.INC Phone: 208 -772 -5165 6600 N.GOVERNMENT WY, COEUR D'ALENE ID 83815 CONTACT JOHN LANG Phone: 206- 281 -8700 101 ELLIOTT AV N; STE 330, SEATTLE, WA 98119 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL HVAC SYSTEM. UMC Edition: 1997 Valuation: 450,000.00 Total Permit Fee: 174.00 ********************************************* * * * * * * * ** * * * * * * * * * * * * * * * * * * ** `j Permit Cerit Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign for and obtain this bu ing perm t. Signature: Date: 2 476.©D Print Name • _ �1 ._et44 .1.�,12v- Title: Said,. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. �.J CITY OF TUKWILA Address: 121.01 TUKWIL.A INTERNATIONAL BL Permit No: M99 -0158 Suite: Tenant: PACIFIC VIEW OFFICE PARK -BLDG C Status: ISSUED Typo: E3-ME CH Applied: 08/11/1999 Parcel #: 092304 -9309 Issued: 01/24/2000 ******************* *k* * * * * * * * * * * * * * * * * * *k * *** ** *A * * *k * ** * ** * * * * * *** * ** * ** Permit Conditions: 1. Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. . Plumbing will be 'inspected by that agency, 'including , all : :gas : piping (296- 4722). 2. 'Electrical permits -shall ,be;. obtalried, through the ,Washington State Division of Labor ::arid . industries and all electrical work will be 'inspected by that ;agency (248-6630). 3. No changes ,will be made to the :plans unless, approved by;.the Engineer and'the Tukwila Building Division. 4. All permits, inspection records, and approved plans shall be available at the job site pri«r to the start of any con- struction. These documents are to be maintained and avail- able until "final inspection approval is granted. 7, All construction to he done in' conformance with approved plans and requirements of the Uniform Building Code (1997 . ,Edition) as amended, Uniform 'Mechanical Code (1997 Edition),' and Washington State " Energy Code (1997 Edition) . . G. Validity of Permit.- The is uance of a:permit or approval; of plans, specifications, and Computations shall not be ,,con strued to be a permit For, or an approval oF, any violation of any of the provisions: of the building code or of any other ,- ordinance of the jurisdiction. No permit, presuming to give authority to violate or cancel the provisions o f this code' shall be valid. 7. Manufacturers installation i nstruct ic>rls . required on site for th,e building inspectors review. CiTY OF Ti "YWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Ap not be aced through the mail or facsimile. Pr•'ir A P^" a fTr a• r: , r V Description of work to be done: , firS-rtil (t UU C:.. _ Will there be storage of flammable /combustible hazardous material in the building? ❑ es ® n o g g y Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets �I- � V:Iue ofConstruction: i sill f 001 d egs. , - Cit State /Zip: Tax Pa I ��??bz�rff Proper Owner: Phone: Street Address: 4 , 0 L AL) �.,t. 30 _411 City State /Zip: ' • Fax #I: as - 2s -.Q 2.0 Contv„t,Person: Phon ?: Street Address: v.,. e City State /Zip: F #f: o-wrC Con : ctor: it. i - Phone: SI 65 •. - 2 -� Q_ - - w - .. Street Address: • d0 .. 6ov•... c ' , - . City State /Zip: . 8381- Fax #: c (S$, 772 (o(S I Ar hitect: • G. t c. ..• l c t• 6 • .. Phone: 8 7 0 O ao . • _ - 7. Street Add f! s: I e. 5�� i-r dl ELL a (,J _ • City State /Zip: t. ' , Fax #: c� G C.--• az - d 0 2c, Ea ineer: T• rr• .. AA ,c_,. _ t.f•� Phone: 0 23 Street Address: cio � L YUe... I+ 2. •..V 1 t'g IS I. ISI. State /Zip: 8J:M-- Fax #: QO:- - _ MISCELLANEOUS;PERMIT REVIEW AND APPROVAL ,REQUESTED: (TO BE:FILLEO:OUT BY'APPLICANr) }<:_ Description of work to be done: , firS-rtil (t UU C:.. _ Will there be storage of flammable /combustible hazardous material in the building? ❑ es ® n o g g y Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks • Antennas /Satellite Dishes ❑ Bulkhead /Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence ❑ Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting APPLICANT: REQUEST. FOR MISCELLANEOUS ;PUBLIC:WORKS.PERMITS ;'.: '. ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer # #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s). 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp if Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load /Hauling MONTHLYSERViCE.BILLINGS Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Phone: Address: City /State /Zip: WErtfro KWiLA Value of Construction - in all cases, a value of construction amount should be entered by the applican6tAislfigurelane reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the daie'rfllar/plidaNNElihall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Data Iicat /o a opted. IMP IMP MISCPMT.DOC 7/11/96 Datapilcat n x1plres :�oto Appl n ke by: (Initials) ALL MISCELLMNEOUS ' •MIT APPLICATIONS MUST BE SU: TED WITH THE FOLLOWING: ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUi OI JG SIT�•I LANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Above Ground Tanks/Water::Tanks : Supported directly, upon grad's: exceeding ,5;000 gallons and a ratio of height to diameter or width which. exceeds:2 :1 Subrnit'cfjecklist' Antennas /Satellite Dishes. Submit: checklist ": Awnings /Canopies.- No.signage Corimmeepial Tenant.IrrmproVement; ., Pe "rmit .Bulkhead /Dock ::: Submit:checklist, : No :: Cornmercial.Reroof: Demolition., Submit checklist ;'Noi; M =6. Suljniitcljeckiist> :: No'- i 3;< Fences -. OVer: 6. feet in fleiglit. Submit`cliecklist > No: Land Altering/Grading /Preloads:.. Submit checklist:: :; No:. M ❑ Loading;Docks Cominercial.Tenant'IMproVerxient• <;. Permit,:`Submit cf ecklist..No: HA: Mechanical`(ReSidentiai &;Commercial)` • • MiscellaneousPublic Works;Permits ❑ Manufactured Housing :(RED.INSIGN.IA -ONLY Submit M= Residential only 6, H =16" Submit checklist';;: No H-9 Submit checklist:', ; No:•• Moving - .Oversized Load /Hauling Parking•Lpts,.. Residential Reroof .Exemptwith;foliowing exception: if,roof structure to be ..repaired <or :replaced Residential Building Permit Submit . ,checklist-`: -No:: M =fit; ❑ Retaining'WOSils Over4.feet in height:,`. ;,Subltiit checklist No Tempo, "racy,: Facilities: Submit'checklist,'!• Temporary Pedestrian :Protection/Ekit'Systems . `Tree'Cuttin Submit checklist :::;No M Submit checklist.;: No:: ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". BulldIng.Owner /Authorlied Agent If the applicant is other.,than the owner,: registered. architect /engineer, or contragtorlicense by the State; of, Washington, a notarized letter from. the property,, owner authorizing the agent to submit this perinit appllcation:an obtain: the permit will be.required.as; part of this submittal. • • . 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING:OWNER'OR AUTHORIZED AGENT:: Signature: j / /f/ . 7t- !l Date: Print nam .1 JJ'L Gto1 /GG �� y% (3-y,;'74 Phone: Fax #: >Address: City /State /Zip: OT r MISCPMT D7/11/96 lc so 11 CITY OF TUKWILA, WA ff\q-015c3 ' TRANSMIT: *************************************************************** TRANSMIT Number: R9800223 Amount: '174400 01/24/00 15:19 Payment, Method: CHECK Notation: PARROTT MECHANIC . Init: TLB • Permit No: M99-0158 Type: B-MECH MECHANICAL PERMIT • Parcel No: 092304-9309 Site Address: 12101 TUKWILA INTERNATIONAL BL Total Fees: • 174.00 This Payment 174.00 Total ALL Pmts: 174.00 Balance: .00. **************************************************************** Account Code Description Amount 000/345.830 PLAN CHECK - NONRES • 34.80 000/322.100 MECHANICAL - NONRES 139.20 6'136..0i/25, 9710 TOTAL: 174 .00 • .... • RECEIVED JINN 2 52060 COMMUNITY DEVELOPMENT INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 PERMIT NO. 06)431 -3670 ProjeW-ob /G• V 1 'TYPe ./sr� I/i� -- A•• •s :, AP Dat Special instructions: Date w t: )9 +', ?!m_ Reques Altle, C. 6-7 Phone: _Zpproved per applicable codes. El Corrections required prior to approval. COMMENTS: El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with peer°mit CITY OF TUKWILA BUILDING DIVISION -12A PERMIT NO. 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Proj 4 f F I C.r th Type of In I AL — A ddress. PA O l ''"E Date called: Kkfl r l �+ 7 V it S ( (�.�.. 1'`�- l� (v Q l� Special instructions: eic.3'905' all Date �r,�te�d: /DU S s P id L a m:'' P.. Requester 17011 C/ .i.:. 'Ne. 7.405 -- 73 jJApproved per applicable codes. VrCorrections required prior to approval. COMMENTS: — J? _ C770. GC TrY-s` al 11 244- Kkfl r l �+ 7 V it S ( (�.�.. 1'`�- l� (v Q l� AP�� S s P id L /. -lo .' 11C _ ' C t ‚2E- c--1.11/4_14e.... A r 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION PERMIT NO. cAc 6300 Southcenter Blvd, #100, Tukwila, WA 98188���J (206)431 -3670 Projjeect:: yA ` ti Type of�spection: Address: f 1 2 0 7 ,I `� : P. Date c called: 0c- / 11100 Special instructions: 7h An "__e?',47/„e Date wanted: Q5 i I21CO a.m. Reque ser:�, 57'ze 77Ati7 gq 1-.15r Phone: _ -W2 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: U/eJ 0 ,e' I,C. fe c7/ oiS x'. / o ff 4/ 2 - 7'0 ,e /0.51, 7-7", c. P i /4 y-Ne S,%' of 4Y 7h An "__e?',47/„e _ y • S7" Z. �, ( A t // 7' i6 /e,7A7",c /_,,t�Cp 4 e:e C 0d /mac (/), ,oG 57'ze 77Ati7 gq 1-.15r © r • Inspect Date: El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. 20 �z_PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r^ 6300 Southcenter Blvd, #100, Tukwila, WA 98188 \ (206)431 -3670 Prgect�cT�, _ �, �t f (�,(� (�� Type qt-l" *t—rni , ,,,' --5'11;21751;12!?'°- PA- t./9 7-047•?: Address: r Di mow.. - \E Date called: Special instructions: Date wanted: a.m. p.m. �v. Reques�ye Phone: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: --5'11;21751;12!?'°- PA- t./9 7-047•?: ---C7 c"7"-- Ys x /,Lt/v (<;-' C 6 60 xe,476b 0 7 -iox / & ,¢ s7-/rc ,, , 5/2'/s orb rt eh/ A_ ?)ireL -A..s /./776.-9-c A7 s.rwiel ii_. ° //y' (�. /7 h, ,'&7) r ye A� &( /xS7 ,TES o, 6(a ©---A 6 ASSQTS ce t14.6; . e'eS ce/.1*./4 4-i r. j /9-A40-#6, te - . ,/''i1-4,'?/ . ___® ,. 1 / aV $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [Receipt No: Date: • ....:.. aw r- o.. S..: Lh;. t t.n•c,,.,.:1.. ,. . ..,r. . . .. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 • PERMIT NO. •. (206)431-3670 oject: a C vl OW 0 (eW Type of Inspection: Sh/Ck7°- -down Date calle : S(OD 01 —1.i. Special instructions: Id@ c; beef' t Date wang /to 1 ) Q a.m. P.m. +Ire Requester: ict)e, Corn 11: trt.• l.)J 1 t....--..- ilNL-re.—• c)n P h re 53— CS' ..1. - pproved per applicable codes. Corrections required prior to approval. COMMENTS: peAffr— 4//J-3 /-P-e 77/70-b At 0.0e _sitokokz.e. p4-mAx. Insp t/ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. 1 (206)431-3670 Project: Pei C. /r/C 14E4/ 8696- (..., Type of InspeYtiOri: A„(&-.. c HAN/lot-L. F--/NA C... Address: /P-101 7; E. 0, Date called: Special instructio lc s: , ‘ , Date wanted: a.m. Requester: Phone: 24 / --- 4/0 ElApproved per applicable codes. tions required prior to approval. COMMENTS: SE-E. I-Vac/to-vs. N ores Aivi" Re.„44.E.1 Ins Date:ci/ 1:1 $47.00 REINSPECTION EEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION NO. ....•••••0 "• •• INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-3670 e aexy 40 Ar, Address W /0/ T . T S. Date called -I-- Special instructions: Date v■;anttl: 57c/Q0 P. . .Rxt.ii.c veo Office Requesplew -ilt 1./( 2101(c Ph..... _..... 2.3,--41.0.5-13// Approved per applicable codes. fl Corrections required prior to approval. COMMENTS: _60 atotwoftwrk Fhee a~,glioe ,-6-7*-Act-tle7 4'(16e65 49 ,'one (A2 97H .4.4969ie .4'7- ..?•tee.: -eifi-obae.:e ,,e/e,,AgehtliV,e6.57"-- /40€9. -,,cfecce_s5 /Ai 41---/z• /4 Ci)-tCE Atorx. 4 V / •-7---6,,.-0 Afar- rb744.6terz, Feeo(7 z2 leL. v/S6-6 "ebtre~/464 Approved per applicable codes. fl Corrections required prior to approval. COMMENTS: _60 atotwoftwrk Fhee a~,glioe ,-6-7*-Act-tle7 4'(16e65 49 ,'one (A2 97H .4.4969ie .4'7- ..?•tee.: -eifi-obae.:e ,,e/e,,AgehtliV,e6.57"-- /40€9. -,,cfecce_s5 /Ai 41---/z• /4 Ci)-tCE Atorx. 4 V / •-7---6,,.-0 Afar- rb744.6terz, Feeo(7 z2 leL. v/S6-6 "ebtre~/464 dAd .tt. - , , ,,zi _ 0 77&-7772-Xl (4444S 71 '14i/f725491,7- airs.cmcie." 16) /for • $ .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: . _ - •/0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 A40itzgr5 PERMIT NO. (206)431-3670 P re4 0 if (I C ofmpection: Type i Athesso: 1 it/4 min_ sc. l Date called: Special instructions: COX.I/244eMe 7V fig-C9//04. tA/SP9Ceolnalif A.../SW-1./c770?t,t5 Date w /q0C) . . Requgstej: al.4;ii4 Pho4., nApproved per applicable codes. rections required prior to approval. COMMENTS: 6 "exuK5 PO Aio -7 - - -/,e P/9"°44's ./Am-ce-i› zoc4 77&71(S. yee--(// 64-4:-f ,e-:v4e616 0 /.e_cr4re.4-7764/ 47 eeze4434464 5-07;/*/70•44 9-1x.ax ,462 0.11407- fri4-XXVie;</cr_S ‘)CCeierr- Xtr" /Sr rcooe. ri $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 1Receipt No: 0 City of Tukwila Fire Department +Pe..41rIgnagitWamos -44 John W. Rants, Mayor • TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Thomas P. Keefe, Fire Chief Permit No . /17 e//' e /5g Project Name j'4J F id z C. Address /D / 7i1 L -3L . Retain current inspection schedule Needs shift inspection kVA Suite # Approved without correction notice Approved with correction notice issued Ct Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: 4,1Ar'a■ 5eepigi41 Pre -Fire: Permits: Authorized Signature D FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station :. 444 Andover Park East • Tukwila, Washington 98188 • Phone: PON 57.5-4404 • Fax (206) 5754439 1 1 DESIGN TEMPERATURE REPORT Block Load 3.05 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. August 09,1999 Page: 1 TABLE 1. DESIGN PARAMETERS Latitude Elevation Summer Design Dry Bulb Temp Summer Coincident Wet Bulb Temp Daily Temperature Range Winter Design Dry Bulb Temp Atmospheric Clearness Number Data Source January 47.5 Degree 386.0 ft 84.0 F 65,0 F 22.0 F 21.0 F 1.05 Carrier Defaults 1, TABLE 2. COOLING DESIGN TEMPERATURE PROFILES (DB(WB in Pi Hour DB WB 000 49.2 46.3 100 48.1 45.8 200 47.0 45.3 300 46.1 44.9 400 45.4 44.5 500 45.2 44.4 600 45.6 44.6 700 46.7 45.2 800 48.7 46.1 900 51.6 47.4 1000 54.9 48.9 1100 58.6 50.6 1200 62.1 52.1 1300 64,8 53,2 1400 66.5 53.9 1500 67.2 54.2 1600 66.5 53.9 1700 65.0 53.3 1800 62.6 52.3 1900 59.7 51.1 2000 56.9 49.8 2100 54.4 48.7 2200 52.2 47.8 2300 50.5 46,9 ADB • WB }' :' MI CO GO \ 55 111 ■ a a ha mill 45 40 0 2 4 6 8 10 12_ 14 16 18 20 22 2 RECEIVED CITY OF TUKWILA AUG 1 1 1998 PERMIT CENTER 4 7yqq.. • c)56 1 DESIGN SOLAR REPORT Block Load 3.05 Location: Seattle - Tacoma, Washington Prepared by: Parrott Mechanical, Inc. August 09, 1999 Page: 1 1. TABLE 1. DESIGN PARAMETERS Latitude Elevation Summer Design Dry Bulb Temp Summer Coincident Wet Bulb Temp Daily Temperature Range Winter Design Dry Bulb Temp Atmospheric Clearness Number Data Source 47.5 Degree 386.0 It 84.0 F 65.0 F 22.0 F 21.0 F 1.05 Carrier Defaults 1. TABLE 2. MAXIMUM SOLAR HEAT GAINS BTU/hr /spit Month NE E SE S SW W NW N HO1t January 16.1 126.7 229.5 258.2 229.5 126.7 16.1 16.1 92.7 February 38.9 177.9 255.0 262.6 255.0 177.9 38.9 21.4 147.7 March 85.1 215.4 250.7 238.5 250.7 215.4 85.1 27.2 200.0 April 139,5 230.0 225.5 193.4 225.5 230.0 139.5 33.1 239.1 May 166.3 229.4 200.2 155.6 200.2 229.4 166.3 37.3 260.5 June 174.0 225.7 187.6 138.3 187.6 225.7 174.0 48.9 266.1 July 164,1 225.0 195.6 151.5 195.6 225.0 164.1 38.6 258.0 August 134.7 221.8 217.5 187.2 217.5 221.8 134.7 34.9 235.5 September 76.8 201.4 239.0 230,2 239.0 201.4 76,8 28,3 193.3 October 37.8 170.6 245.6 253.9 245.6 170.6 37.8 22.2 145.5 November 16.5 123.7 224.8 253.6 224.8 123.7 16.5 16.5 92.7 December 13.8 97.3 207.5 246.7 207.5 97.3 13.8 13.8 71.0 r 1 SYSTEM INPUT REPORT System: Level Location: Sattle•Tacoma, Washington Prepared by: Parrott Mechsnksl, Inc. Block Load 3.05 August 09, 1999 Page: 1 TABLE 1. HVAC SYSTEM DESCRIPTION System Typo System Start Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety Clg and Warm Air Ht 6:00 24 hrs 57.0 F 25.00 CFM/Per 0.00 CFM 0.050 0% 0 % O % THERMOSTAT SETPOINTS Cooling (Oco.) Cooling (Unoco.) Heating RETURN AIR PLENUM FAN Configuration Static Pressure 75.0 F 75.0 F 72.0 F No Blow Thru 1.50 in. wg. TABLE 2. SYSTEM ZONING INFORMATION System Arrangement: Total Zones Selected: Selected Zones: AU zones served by a common air handier 1 1) RTU 1 i 1 SYSTEM SIZING SUMMARY System: Level 1 Location: Seattle - Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 1 TABLE 1. SIZING DATA (COOLING) 1 Total Coil Load Sensible Coil Load Total Zone Sensible Supply Temperature Supply Air (Actual) Supply Air (Standard) Ventilation Air Direct Exhaust Air Reheat Required 487,491 BTU/hr 477,935 BTU/hr 430,819 BTU/hr 57.0 F 22,473 CFM 22,161 CFM 3,280 CFM 0 CFM 0 BTUAw Floor Area 18,500 sgft Overall U -Value 0.395 BTUAor/agtt/F Vent Air 0.18 CPM/sgft Vent Air 25.00 CFM/Perwu (TABLE 2. SIZING DATA (HEATING) Heating Coil Loud 324,175 BTUArr Ventilation Load Total Zone Load Veatiladon Airflow Supply Airflow 178,164 BTU/hr 146,011 BTUAv 3,280 CFM 22,473 CFM Load Occurs OutdoorDb/Wb Coil Condi ioaa: Entering Db/Wb Leaving Db/Wb Apparatus Dewpoint Bypass Factor Resulting Zone RH Total Cod Load Sensible Coil Load SQFT/Ton Cooling Coggin. September 14:00 81.3/63.8 F 77.0/63.7 F 57.0/56.4 F 55.9 F 0.050 52.9 % 40.62 Ton 3983 Ton 455.39 26.35 BTU/br/sgft 1.21 C.FM/saft Heating Heating Floor Area Overall U -Value Vent Air Vent Mr 17.52 BTUArr /sgft 1.21 CFM/sgft 18,500 sgft 0.395 0.18 CFM/sgft 25.00 CFM/Person 1 TABLE 3. INPUT DATA (WEATHER) Location Data Source Latitude Elevation Allenar heric Mimosa tw Seattle - Tacoma, Washington Carrier Defaults 47.5 Degree 386.0 ft LIM Summer Dry -Bulb Coincident Wet -Bulb Daily Range Winter Dry -Ruth 84.0 F 65.0 F 22.0 F 21.0 F TABLE 4. INPUT : AC SYSTE System Name System Type System Start Duradoa SIZING SPECIFICATIONS Supply Veatilatlon Exhaust FACTORS Con Bypass Safety (Sens) Safety (Latent) Beating Safety Level 1 Cig and Warm Air Ht 6:00 24 ton 57.0 F 25.00 CFM/person 0.00 CFM 0,050 0 0 '/. THERMOSTAT SETPOINTS Cooling (Om.) Cooling (Unocc.) Heating RETURN AIR PLENUM FAN Configuration Static Pressure 75.0 F 75.0 F 72.0 F No Blow Thru 1.50 in. wg. TABLE 5. TOP TEN COOLING COIL LOADS Time Sensible Ton Total Ton 1) September 14:00 39.83 40.62 2) August 14:00 39.00 40.09 3) September 13 ;00 39.16 39.94 4) August 13:00 38.24 39.32 5) September 15:00 38.42 39.20 Time Sensible Tort Total Too 6) August 15:00 37.91 39.00 7) September 12:00 37.68 38.44 8) October 14:00 38.22 38.34 9) July 14:00 37,20 38.27 10) October 13:00 37.83 37.94 SYSTEM SIZING SUMMARY System: Level 1 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 2 TABLE 6. ZONE SIZING DATA Zone Name RTU -1 Max. Cooling Sensible (BTU/hr) 430,819 Total: Design Airflow Rate (CFM) Design Time 22,473 September 14:00 22,473 Max. Heating Design Flow Load Rate (BTU/hr) (CFM) 146,011 - Total: .00 DETAILED SYSTEM LOAD REPORT System: Level 1 Location: Seattk- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 1 L TABLE 1. CALCULATION INFORMATION 1 Design Load: September 14:00 Db/Wb Temp 81.3/ 63.8 F Winter Design Te,nn 21.0 F TABLE 2. LOAD COMPONENT SUMMARY TABLE 3. WALL AND GLASS BREAKDOWN Load Component Details Design Cooling Loads Sensible Latent (BTU/hr) (BTU/dr) Design Heating (BTU/ir) Heating Transmission (BTU/hr) Solar Loads 5,436 sqft 218,170 - o - o Wall Tranamission 1,812 sqft 571 - 4,621 136 - Roof Transmission 0 sqft 0 - 0 0 0 Glass Transmission 5,436 sqft 6,715 - 141,390 S 654 Skylight Transmission 0 sqft 0 - 0 SW Partitions 0 agft 0 - 0 Lighting 2.00 W/sqft 125,959 - - 643 Other Electric 0.75 W /agft 47,309 - - - o People 131 People 32,095 26,897 - -42 - InAltration 0 0 0 o 0 Miscellaneous 0 0 0 - E 756 Slab 0 sqft - - 0 SE Pulldown/Wann -Up 0 0 - - Safety Factor 0/0/0 % 0 0 0 51,032 Total Zone Loads SW 430,819 26,897 146,011 0 0 Ventilation Load 3,280 CFM 22,148 - 17,361 178,164 934 38,357 Supply Fan Load 22,473 CFM 24,988 - - 0 0 Plenum Load thru Wall 0 % 0 - - N 1,962 Plenum Load thru Roof 0 % 0 - - Hor Pkaam Load - Lights 0 % 0 - - Reheat Load 0 - - Total Coil Lards 477.955 9.536 324.175 TABLE 3. WALL AND GLASS BREAKDOWN Component Total Net Am (sqft) Cooling Transmission (BTUAir) Cooling Solar Load (BTU/hr) Heating Transmission (BTU/hr) Walls: NE o o - o E 252 136 - 643 SE 0 0 - 0 S 654 460 - 1,668 SW o o - o W 252 18 - 643 NW o 0 - o N 654 -42 - 1,668 Glass: NE o 0 0 0 E 756 934 12,653 19,664 SE 0 0 0 0 S 1,962 2,424 146,120 51,032 SW 0 0 0 0 W 756 934 38,357 19,664 NW 0 0 0 0 N 1,962 2,424 21,040 51,032 Hor 0 0 0 0 1 DETAILED ZONE LOAD REPORT System: Level 1 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09, 1999 Page: 1 TABLE 1. GENERAL INFORMATION Zone Name: System Name: Design Load: Db/Wb Temp: RTU-1 Level September 14:00 81.3/63.8 F TABLE 2. LOAD COMPONENT SUMMARY Load Component Details Design Cooling Loads Sensible (BTU/hr) Design Heating (BTU/hr) Solar Loads 5,436 agft 218,170 - Wall Transmission 1,812 agft 571 4,621 Roof Transmission 0 agft 0 0 Glass Transmission 5,436 sqft 6,715 141,390 Skylight Transmission 0 sgft 0 0 Partitions 0 agft 0 0 Lighting 2.00 W /sgft 125,959 - Other Electrio 0.75 W /sgft 47,309 - People 131 People 32,095 - Infiltration 654 0 0 Miscellaneous NE 0 - Slab 0 sgft - 0 Pulldown/Warm -Up 12,653 0 - Safety Factor 0/ 0 % 0 0 Total Zone Loads 1,962 430,819 146,011 1 TABLE 3. WALL AND GLASS BREAKDOWN Walls: Glass: Component Total Net Area (sgtl) Cooling Transmission (BTU/hr) Cooling Solar Load (BTU/hx) Heating Transmission (I3TU/hr) NE 0 0 - 0 E 252 136 - 643 SE 0 0 - 0 S 654 460 - 1,668 SW 0 0 - 0 W 252 18 - 643 NW 0 0 - 0 N 654 -42 - 1,668 NE 0 0 0 0 E 756 934 12,653 19,664 SE 0 0 0 0 S 1,962 2,424 146,120 51,032 SW 0 0 0 0 W 756 934 38,357 19,664 NW 0 0 0 0 N 1,962 2,424 21,040 51,032 Hor 0 0 0 0 SYSTEM INPUT REPORT System: Level 2 Location: Seattle - Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09, 1999 Page: 1 TABLE 1. HVAC SYSTEM DESCRIPTION System Typo System Start Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FACTORS Cori Bypass Safety (Sens) Safety (Latent) Heating Safety Clg and Warn Air Ht 6:00 24 hrs 57.0 F 25.00 CFM/Per 0.00 CFM 0.050 0 0 0 THERMOSTAT SETPOINTS Cooling (Occ.) Cooling (Unocc.) Heating RETURN AIR PLENUM FAN Configuration Static Pressure 75.0 F 75.0 F 72.0 F No Blow Thru 1.50 in. wg. TABLE 2. SYSTEM ZONING INFORMATION System Arrangement: Total Zones Selected: All canes served by a common air handier 1 Selected Zones: 1) RTU -2 SYSTEM SIZING SUMMARY System: Level 2 Location: Seattle- Taconu, Washington Prepared by: Parrott Mechanical, Inc. Blockload 3.05 August 09, 1999 Page: 1 TABLE 1. SIZING DATA (COOLING) ANSIIMINRHINI Total Coil Load Sensible CoU Load Total Zone Sensible Supply Temperature Supply Air (Actual) Supply Air (Standard) Ventilation Mr Direct Exhaust Air Reheat Required 328,486 BTUAtr 322,444 BTUArr 292,003 BTUThr 57.0 F 15,232 CFM 15,021 CFM 2,000 CFM Q CFM O BTU/hr Floor Area 18,100 341f Overall U -Value 0.324 BTU/hr /sgf/F Vent Air 0.11 CFM/gf Vest Air 250 CFM/Perao0. {TABLE 2. SIZING DATA (HEATING) Heating Cop Load 228,462 BTUArr Ventilation Load Tota Zone Load Ventilation Alrnow Supply Airflow 108,632 BTUAtr 119,830 BTU/br 2,000 CFM 15,232 CFM Load Occ ua September 14:00 Outdoor Db/Wb 81.3/63.8 F Con Conditions: Entering Db/Wb Leaving Db/Wb Apparatus Dewpolnt Bypass Factor Resulting Zone RH Total Con Load Sensible Coil Load SQFT/I on Cooling CmUne • Heating Heating Floor Area Overall U -Value Vent Air Vest Mr 76.9/63.7 F 57.0/36.4 F 56.0 F 0.050 52.8 % 27.37 Ton 26.87 Ton 661.22 18.15 BTU/hr /qf 0.84 CFM /salt 12.62 BTUAv /gf 0.84 CFM/sgf 18,100 sqft 0.324 0.11 CFM/gR 25.00 CFM/Person 1 LTABLE 3. INPUT DATA (WEATHER) 1 Location Data Source Latitude Elevation Seattle - Tacoma, Washington Carrier Defaults 47.5 Degree 386.0 ft TABLE 4. INPUT (HVAC SYSTEM) System Name System Type System Start Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FACTORS Coil Bypass Safety (Seas) Safety (Latent) Heating Safety Level 2 Clg and Warm Air Ht 6:00 24 bra 57.0 F 25.00 CFM/person 0.00 CFM 0.050 Summer Dry-Bulb Coincident Wet -Bulb Daily Range 84.0 F 65,0 F 22.0 F THERMOSTAT SETPOINTS Cooling (Occ.) Cooling (Unocc.) Heating RETURN AIR PLENUM FAN Configuration Static Pressure 75.0 F 75.0 F. 72.0 F No Blow -Thru 1.50 in. wg. TABLE 5. TOP TEN COOLING COIL LOADS Time 1) September 14:00 2) September 13:00 3) August 14:00 4) August 13:00 5) September 15:00 Setuibk Ton 26.87 26.48 26.08 25.62 25.66 Total Toa 27.37 26.98 26.76 26.29 26.16 Time Sensible Ton Total Ton 6) September 12:00 25.46 25.95 7) October 14:00 25.80 25.89 8) August 15 :00 2113 25.81 9) October 13 :00 25.63 25.71 10) July 14:10 2462 25.29 SYSTEM SIZING SUMMARY System: Level2 Location: Seattle- Tacoma, Wuhington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 2 TABLE 6. ZONE SIZING DATA Zone Name RTU -2 Max. Cooling Sensible (BTU/hr) 292,003 Total: Design Airflow Rate (CFM) Design Time 15,232 September 14:00 15,232 Max. Heating Load (BTU/hr) 119,830 Total: Design Flow Rate (CFM) .00 DETAILED SYSTEM LOAD REPORT System: Level 2 Location: Seattle- Tacoma, Washington Prepared by Parrott Mechanical, Inc. Block Load 3.05 August 09, 1999 Page: 1 1. TABLE 1. CALCULATION 'INFORMATION 1 Design Lead: September 14:00 Db/Wb Temp 81.3/ 63.8 F Wintrr Ilrwbe Timm 21.0 P 2. LOAD COMPONENT SUMMARY LE 3. WALL AND GLASS BREAKDOWN 1. Losd Component Details Design Cooling Sensible (BTU/hr) Loads Lateat (BTU/hr) CooWg Solar Load (IiTU/br) Design Heating (BTU/hr) Solar Loads 4,320 sqft 173,749 - - - Wall Transmission 2,928 sqft 923 - - 7,466 Roof Trenunluioa 0 sqft 0 - - 0 Glass Traaitaission 4,320 sqft 5,336 - - 112,363 Skylight Traaasmbslon 0 sqft 0 - - 0 Partitions 0 sqft 0 - - 0 Lighting 1.50 W /sgft 92,427 - - - Other Electric 0.00 W /sgft 0 - - - People 80 People 19,569 16,400 0 - Inftltration E 0 0 9,707 0 Miscellaneous SE 0 0 = - Slab 0 sqft - - 117,670 0 PuUdown/Warm -Up SW 0 - 0 - Safety Factor 0/0/0 % 0 0 29,427 0 Total Zone Loads NW 292,003 16,400 0 119,830 Ventilation Load 2,000 CFM 13,504 - 10,359 16,944 108,632 • Supply Fan Load 15,232 CFM 16,936 - 0 - Plenum Load them Wall 0 % 0 - - Plenuan Load thru Roof 0 % 0 - - Pkaasm Laid - Lights 0 % 0 - - Reiaeat Load 0 - - Total roll Loads 322.444 6.041 128.462 , LE 3. WALL AND GLASS BREAKDOWN 1. Component Total Net Area (agft) Coaling Transmission (BTU/hr) CooWg Solar Load (IiTU/br) Heating Transmission (BTU/6r) Walls: NE 0 0 - 0 E 428 231 - 1,091 SE 0 0 - 0 S 1,036 728 - 2,642 SW 0 0 - 0 W 428 30 - 1,091 NW 0 0 - 0 N 1,036 -67 - 2,642 Glass: NE 0 0 0 0 E 580 716 9,707 15,086 SE 0 0 0 0 S 1,580 1,952 117,670 41,096 SW 0 0 0 0 W 580 716 29,427 15,066 NW 0 0 0 0 N 1,580 1,952 16,944 41,096 • Hor 0 6 0 0 M C1. DETAILED ZONE LOAD REPORT Systan: Level 2 Location: Seattle - Tacoma, Washington Prepared by Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 1 TABLE 1. GENERAL INFORMATION Zone Name: System Name: Design Load: DblWb Temp: RTU -2 Level 2 September 14:00 81.3/63.8 P 1 TABLE 2. LOAD COMPONENT SUMMARY 1 Load Component Details Design Cooling Loads Sensible ( BTU/hr) Design Heating ( BTU/hr) Solar Loads 4,320 agft 173,749 - Wall Transmission 2,928 sqft 923 7,466 Roof Transmission 0 sqft 0 0 Glass Transmission 4 ,320 sqft 5,336 112,363 Skylight Transmission 0 sqft 0 0 Partitions 0 sqft 0 0 Lighting 1.50 W/sqft 92,427 - Other Electric 0,00 W /agft 0 - People 80 People 19,569 - Infiltration 1,036 0 0 Miscellaneous NE 0 - Slab 0 sqft - 0 Pulldown/Warm -Up 9,707 0 - Safety Factor 0/ 0 % 0 0 Total Zone Loads 1,580 292,003 119,830 Walls: Glass: TABLE 3. WALL AND GLASS BREAKDOWN Component Total Net Area (sqft) Cooling Transmission (BTU/hr) Cooling Solar Load ( BTU/hr) Heating Transmission ( BTU/hr) NE 0 0 - 0 E 428 231 - 1,091 SE 0 0 - 0 S 1,036 728 - 2,642 SW 0 0 - 0 W 428 30 1,091 NW 0 0 - 0 N 1,036 -67 - 2,642 NE 0 0 0 0 E 580 716 9,707 15,086 SE 0 0 0 0 S 1,580 1,952 117,670 41,096 SW 0 0 0 0 W 580 716 29,427 15,086 NW 0 0 0 0 N 1,580 1,952 16,944 41,096 Hor 0 0 0 .0 SYSTEM INPUT REPORT System: Level 3 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 1 1 TABLE 1. HVAC SYSTEM DESCRIPTION System Typo System Start Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FACTORS Cot? Bypass Safety (Sens) Safety (Latent) Heating Safety Clg and Warm Air Ht 6:00 24 hrs 57.0 F 25.00 CFM/Per 0.00 CFM 0.050 0 0 THERMOSTAT SETPOINTS Cooling (Occ.) Cooling (Unocc.) Heating RETURN AIR PLENUM FAN Configuration Static Pressure 75.0 F 75.0 F 72.0 F No Blow Thru 1.50 in. wg. TABLE 2. SYSTEM ZONING INFORMATION System Arrangement•. Total Zones Selected: Selected Zones: All zones served by a common air handler 1 1) RTU-3 1 SYSTEM SIZING SUMMARY System: Level 3 Location: Seattle - Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09, 1999 Page: 1 [TABLE 1. SIZING DATA (COOLING) Total Coil Load Sensible Coil Load Total Zone Sensible Supply Temperature Supply Mr (Actual) Supply Air (Standard) Ventilation Mr Direct Exhumed Air Reheat Required 490,035 BTU/br 480,796 BTII/6r 434,636 BTU/br 57.0 F 22,672 CFM 22,358 CFM 3,103 CFM 0 CFM 0 BTU/br Load Occurs Outdoor Db/Wb Coil Conditions: Entering Db/Wb Leaving Db/Wb Apparatus Dewpoint Bypass Factor Resulting Zone RH September 14:00 81.3/63.8 F 76.9/63.7 F 57.0/56.4 F 56.0 F 0.050 52.8 % Total Coil Load 40.84 Ton Floor Area 17,500 sgft Sensible Coil Load 40.07 Ton Ove al U -Value 0.395 BTV/br/sgft/F SQFT/Ton 428.54 Vent Air 0.18 CFM/sgf Cooling 28.00 BTUAtr /sglt Vent Air 2.5.00 C'.FM/Person Cneija* 1.30 CFM/saft [TABLE 2. SIZING DATA SHEATING) Heating Cail Load 314,545 BTU/hr Heating 17.97 BTU/lir /sqe Ventilation Load 168,534 BTU/hr Heating 1.30 CFM/sgtt Total Zone Load 146,011 BTU/hr Floor Area 17,500 sglt Ventilation Airflow 3,103 CFM Overall U -Value 0.395 Supply Airflow 22,672 CFM Vent Air 0.18 CFM/sglt Vent Mr 25.00 CFM/Petson 1 TABLE 3. INPUT DATA (WEATHER) Location Seattle- Tacoma, Washington Data Source Carrier Defaults Summer Dry -Bulb 84.0 F Latitude 47.5 Degree Coincident Wet -Bulb 65.0 F Elevation 386.0 R Daily Raoge 22.0 F AteurnLwrie ClcarnMS d 1 nS WiNrr Dry Rndh 21.0 F [TABLE 4. INPUT (HVAC SYSTEM) System Name Level 3 System Type Clg sad Warm Mr Ht System Start 6:00 Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety 24 hrs 57.0 F 25.00 CFM/persoe 0.00 CFM 0.050 0 0 0 THERMOSTAT SETPOINTS Cooling (Occ.) 75.0 F Cooling (Unocc.) 75.0 F Heating 72.0 F RETURN AIR PLENUM No FAN Configuration Blow-Tbru Static Pressure 1.50 in. wg. TABLE S. TOP TEN COOLING COIL LOADS Time 1) September 14:00 2) August 14:00 3) September 13:00 4) August 13 :00 5) September 15:00 Sensible Ton 40.07 39.21 39.42 38.47 38.64 Total Ton Time Sensible Ton Total Ton 40.84 6) August 15:00 38.11 39.15 40.26 7) September 12:00 37.99 38.73 40.18 8) October 14:00 38.52 38.65 39.51 9) July 14 :00 37.40 38.44 39.40 10) October 13 :00 38.15 *27 SYSTEM SIZING SUMMARY System: Level 3 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09, 1999 Page: 2 TABLE 6. ZONE SIZING DATA Zone Name RTU -3 Max. Cooling Sensible (BTU/hr) 434,636 Total: Design Airflow Rate (CFM) Design Time 22,672 September 14:00 22,672 Max. Heating Load (BTU/hr) 146,011 Total: Design Flow Rate (CFM) .00 DETAILED SYSTEM LOAD REPORT System: Level3 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 1 TABLE 1. CALCULATION INFORMATION Design Lod: DblWb Temp Winter Design T mn September 14:00 81.3/ 63.8 F 21.0 F TABLE 2. LOAD COMPONENT SUMMARY TABLE 3. WALL AND GLASS BREAKDOWN Load Component Details Design Cooling Loads Sensible Latent (IITU/hr) (BTU/br) Design Heating (BTU/br) Heating Transmission (BTU/hr) Solar Loads 5,436 sqft 218,170 - - - o Wail Transmission 1,812 sqR 571 - 4,621 136 - Roof Transmission 0 sqft 0 - 0 0 0 Glass Transmiuion 5,436 sqft 6,715 - 141,390 8 654 Skylight Transmission 0 sqft 0 - 0 SW Partitions 0 sqft 0 - 0 Lighting 2.00 W /sgft 119,150 - - 643 Other Electric 1.00 W /sgft 59,670 - - - 0 People 124 People 30,360 25,443 - I Infiltration 0 0 0 0 0 Miscellsneom 0 0 0 - E 756 Slab 0 sqft - - 0 SE Puildown/Wsrm -Up 0 0 - - Safety Factor 0/0/0 % 0 0 0 51,032 Total Zone Loads SW 434,636 25,443 146,011 0 0 Ventilation Load 3,103 CFM 20,951 - 16,204 168,534 934 38,357 Supply Fan Load 22,672 CFM 25,209 - - 0 0 Plenum Lod thru Wall 0 7. 0 - - N 1,962 Plenum Lod turn Roof 0 % 0 - - Hor Plenwn Load - Lights 0 % 0 - - Reheat Load 0 - - Toird Coif Lode 480.796 9.239 314.545 TABLE 3. WALL AND GLASS BREAKDOWN Component Total Net Area (sqft) Cooling Transmission (BTU/hr) Cooling Solar Load (BTU/hr) Heating Transmission (BTU/hr) Walls: NE 0 0 - o E 252 136 - 643 SE 0 0 - 0 8 654 468 - 1,668 SW 0 0 - 0 W 252 18 - 643 NW 0 0 - 0 N 654 -42 1,668 Glass: NE 0 0 0 0 E 756 934 12,653 19,664 SE 0 0 0 0 5 1,962 2,424 146,120 51,032 SW 0 0 0 0 W 756 934 38,357 19,664 NW 0 0 a 1 N 1,962 2,424 21,040 51,032 Hor 0 a 0 0 1 DETAILED ZONE LOAD REPORT System: Level 3 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechankal, Inc. Block Load 3.05 August 09,1999 Page: 1 TABLE 1. GENERAL INFORMATION Zone Name: System Name: Design Load: Db/Wb Temp: RTU-3 Level 3 September 14:00 81.3/63.8 F 1 TABLE 2. LOAD COMPONENT SUMMARY Load Component Details Design Cooling Loads Sensible (BTU/hr) Design Heating (BTU/br) Solar Loads 5,436 sqft 218,170 - Wall Transmission 1,812 sqft 571 4,621 Roof Transmission 0 sqft 0 0 Glass Transmission 5,436 sqft 6,715 141,390 Skylight Transmission • 0 sqft 0 0 Partitions 0 sqft 0 0 Lighting 2.00 W /sqft 119,150 - Other Electric 1.00 W /sqft 59,670 - People 124 People 30,360 - Infiltration 654 0 0 Miscellaneous NE 0 - Slab 0 sqft - 0 Pulldown/Warm -Up 12,653 0 - Safety Factor 0/ 0 % 0 0 Total Zone Loads 1,962 434,636 146,011 1 TABLE 3. WALL AND GLASS BREAKDOWN Walls: Glass: Component Total Net Area (sqft) Cooling Transmission (BTU/hr) Cooling Solar Load (BTU/hr) Heating Transmission (BTU/hr) NE 0 0 - 0 E 252 136 - 643 SE 0 0 - 0 S 654 460 - 1,668 SW 0 0 - 0 W 252 18 - 643 NW 0 0 - 0 N 654 -42 - 1,668 NE 0 0 0 0 E 756 934 12,653 19,664 SE 0 0 0 0 S 1,962 2,424 146,120 51,032 SW 0 0 0 0 W 756 934 38,357 19,664 NW 0 0 0 0 N 1,962 2,424. 21,040 51,032 Hor 0 0 0 0 SYSTEM INPUT REPORT System: Level4 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09, 1999 Page: 1 1 TABLE 1. D VAC SYSTEM DESCRIPTION System Typc System Start Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety Clg and Warm Air Ht 6:00 24 bra 57.0 F 25.00 CFM/Per 0.00 CFM 0,050 0 0 % THERMOSTAT SETPOINTS Cooling (Occ.) Cooling (Unocc.) Heating RETURN AIR PLENUM FAN Configuration Static Pressure 75.0 F 75.0 F 72.0 F No Blow Thtu 1.50 in. wg. 1 TABLE 2. SYSTEM ZONING INFORMATION 1 System Arrangement: Total Zones Selected: AU zones served by a common air handler 1 Selected Zones: 1) RTU-4 M 1 SYSTEM SIZING SUMMARY System: Level 4 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechankal, Inc. Block Load 3.05 August 09, 1999 Page: 1 TABLE 1. SIZING DATA (COOLING) Total Cal Load Sensible Coil Load Total Zone Sensible Supply Temperature Supply Air (Actual) Supply Air (Standard) Ventilation Air Direct Exhaust Air Reheat Required 331,043 BTU/br 324,143 BTU/hr 290,418 BTU/hr 57.0 F 15,149 CFM 14,939 CFM 2,500 CFM O CFM O BTU/hr Floor Area 17,100 sqft Overall U -Value 0.135 BTU/hr/sgft/F Vent Air 0.15 CFM/sqft Vent Air 24.00 CFM/Penee [TABLE 2. SIZING DATA (HEATING) Heating Coil Load 303,641 BTU/hr Ventilation Load Total Zone Load Ventilation Airflow Supply Airflow 135,790 BTU/hr 167,851 BTU/hr 2,500 CFM 15,149 CFM Load Occurs Outdoor Db/Wb Coil Conditions: Entering Db/Wb Leaving Db/Wb Apparatus Dewpoint Bypass Factor Resulting Zone RII Total Coil Load Sensible Coil Load SQFT/Ton Cooling Cenlh►r September 14:00 81.3/63.8 F 77.1/63.8 F 57.0/56.4 F 55.9 F 0.050 53.1 % 27.59 Ton 27.01 Ton 619.86 19.36 BTU/hr/sqft 0.89 CFM /soft Heating Heating Floor Area Overall U•Value Vent Air Vent Air 17,76 BTU/hr/sqft 0.89 CFM/sqft 17,100 sqft 0,135 0.15 CFM/sqft 25.00 CFM/Person 1 [TABLE 3. INPUT DATA (WEATHER) Location Data Source Latitude Elevation Atrmobeiic Clearness [TABLE 4. INPUT (HVAC Sytem Name System Type System Start Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FACTORS Coil Bypass Safety (Sena) Safety (Latent) Beating Safety Seattle- Tacoma, Washington Cartier Defaults 47.5 Degree 386.0 ft 1.04 Summer Dry-Bulb Coincident Wet -Bulb Daily Range Winter r)ry -itulb SYSTEM) 84.0 F 65.0 F 22.0 F 21.0 F Level 4 Clg and Warm Air Ht 6:00 24 hrs 57 .11 F 25.00 CFM/person 0.00 CFM 0.050 0 Te O % O To THERMOSTAT SETPOINTS Cooling (Occ.) 75.0 F Cooling (Unocc.) 75.0 F Heating 72.0 F RETURN AIR PLENUM No FAN Configuration Blow -That Static Pressure 1.50 in. wg. TABLE 5. TOP TEN COOLING COIL LOADS 1) 2) 3) 4) 5) Tlse September 14:00 August 14:00 September 13:00 August 13 :00 August 15:00 Sensible Ton 27.01 26.58 26.35 25.83 25.72 Total Ton 27.59 27,39 26.91 26.62 26.51 Time Sensible Ton Total Ton 6) September 15:00 25.84 26.40 7) July 14:00 25.17 25.96 8) September 12 :00 25.00 25.55 9) Jiffy 15:00 24.62 25.40 10) October 14:00 25.28 25.33 SYSTEM SIZING SUMMARY System: Level 4 Location: Seattle- Tacane, Washington Prepared by: Parrott Mechankal, Inc. Block Load 3.05 August 09, 1999 Page: 2 TABLE 6. ZONE SIZING DATA Zone Name RTU-4 Max. Cooling Sensible (BTU/hr) 290,418 Total: Design Airflow Rate (CFM) Design Time 15,149 September 14:00 15,149 Max. Heating Design Flow Load Rate (BTU/hr) (CFM) 167,851 - Total: 00 DETAILED SYSTEM LOAD REPORT System: Level 4 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09,1999 Page: 1 TABLE 1. CALCULATION INFORMATION Design Load: September 14:00 Db/Wb Temp 81.3/ 63.8 F Winter (lesion Tcmn 21.0 F TABLE 2. LOAD COMPONENT SUMMARY TABLE 3. WALL AND GLASS BREAKDOW Walb: Load Component Details Design Cooling Loads Sensible Latent (BTU/br) (BTU/tu) Design Heating (BTU/hr) Hearing Transmission (BTU/hr) Solar Loads Wall Transmission 4,880 sqft 2,368 sqft 195,832 - 747 - 6,038 o Roof Transmission 17,100 sqft 5,137 - 34,884 836 Glass Transmission 4,880 sqft 6,028 - 126,929 - 0 Skylight Transmission 0 sqft 0 - 0 602 - Partitions 0 sqft 0 - 0 0 0 Lighting 1.00 W /sqR 58,214 - - W 328 Other Electric 0.00 W /sgft 0 - - NW People 100 People 24,461 20,500 - Infiltratlon 856 0 0 0 2,183 Miscellaneous NE 0 0 - 0 0 Slab 0 sqft - - 0 840 11,381 Pulldown/Warm-Up 0 - - 0 9 Safety Factor 0/0/0 •/. 0 0 0 S 1,760 Total Zone Loads 131,076 290,418 20,500 167,851 SW Ventilation Load 2,500 CFM 16, : : 1 - 13,600 135,790 Supply Fan Load 15,149 CFM 16,844 - - 17,687 Plenum Load din Wad 0 •/. 0 - - 0 0 Plenum Load thru Roof 0 % 0 - - 2,174 18,874 Plenum Load - Lights 0 7 0 - - 0 0 Reheat Load 0 0 - - Total Coil Loads 324.143 6,900 303.641 TABLE 3. WALL AND GLASS BREAKDOW Walb: Component Total Net Area (sqft) Cooling Transmission (BTU/hr) Cooling Solar Load (BTU/br) Hearing Transmission (BTU/hr) NE o o - o E 328 177 - 836 SE 0 0 - 0 S 856 602 - 2,183 SW 0 0 - 0 W 328 23 - 836 NW 0 0 - 0 N 856 -55 - 2,183 Glass: NE o 0 0 0 E 680 840 11,381 17,687 SE 0 9 0 0 S 1,760 2,174 131,076 45,778 SW 0 0 0 0 W 680 840 34,501 17,687 NW 0 0 0 0 N 1,760 2,174 18,874 45,778 Hor 0 0 0 0 DETAILED ZONE LOAD REPORT System: Level 4 Location: Seattle- Tacoma, Washington Prepared by: Parrott Mechanical, Inc. Block Load 3.05 August 09, 1999 Page: 1 1 TABLE 1. GENERAL INFORMATION Zone Name: System Name: Design Load: Db/Wb Temp: RTU-4 Level 4 September 14 :00 81.3/ 63.8 F TABLE 2. LOAD COMPONENT SUMMARY Load Component Details Design Cooling Loads Sensible ( BTU/hr) Design Heating ( BTU/hr) Solar Loads 4,880 sqft 195,832 - Wall Transmission 2,368 sqft 747 6,038 Roof Transmission 17,100 sqft 5,137 34,884 Glass Transmission 4,880 sqfl 6,028 126,929 Skylight Transmission 0 sqft 0 0 Partitions 0 sqft 0 0 Lighting 1.00 W /sgft 58,214 - Other Electric 0.00 W /sgft 0 - People 100 People 24,461 - Infiltration 856 0 0 Miscellaneous NE 0 - Slab 0 sgft - 0 Pulldown/Warm -Up 11,381 0 - Safety Factor 0/ 0 % 0 0 Total Zone Loads 1,760 290,418 167,851 TABLE 3. WALL AND GLASS BREAKDOWN 1 Walls: Glass: Component Total Net Area (sqft) Cooling Transmission (BTU/hr) Cooling Solar Load (BTU/hr) Heating Transmission ( BTU/hr) NE 0 0 - 0 E 328 177 - 836 SE 0 0 - 0 S 856 602 - 2,183 SW 0 0 - 0 W 328 23 - 836 NW 0 0 - 0 N 856 -55 - 2,183 NE 0 0 0 0 E 680 840 11,381 17,687 SE 0 0 0 0 S 1,760 2,174 131,076 45,778 SW 0 0 0 0 W 680 840 34,501 17,687 NW 0 0 0 0 N 1,760 2,174 18,874 45,778 Hor 0 0 0 0 17-03 -2000 1:I9PM FirM POGGEMEYER "DES I GN 429828484 RECEIVED MAY 15 2000 COMMUNITY DEVELOPMENT May 3, 2000 Mr. Haynes Lund Sabey Corporation 12201 Tukwila Intemational Blvd., Fourth Floor Seattle, WA 98168 -5121 Dear Mr. Lund: RE: Building B rooftop anchorage International Gateway Corporate Park 12201 International Blvd. Tukwila, WA P. 2 P-7 PQGGEMEYER DESIGN GROUP CONSULTING ENGINEERS The as -built connections of the large air handling units to the concrete roof slab are: 'h inch X 6 inch Hilti expansion anchors in lieu of epoxy anchors as specified. Reference: sheet S2 and detail 5 /S2 of the structural drawings by Nelson- Bourdages dated October 14, 1999, revision #2. This substitution is an acceptable alternate. Please call if you have further questions or comments. Sincerel (it Ro • = Bourdages, P.E. Dire or, NW Division Poggemeyer Design Group, Inc. PDG 99065 • Poggemeyer Design group, Inc. 512 Sixth Street South, Suite 202 Kirkland, WA 98033 (425) 827.5995 Fax (4251 828-4850 L 1 Vu ♦.L.L J t' —14 -2000 1 : B4PM FROM IVELS(JN "BOUFRDAan- 4258284850 January 14, 2000 ( _ r'N" . Mr. Duane GTII % Building inspector, City of Tukwila 6300 Southecnter Boulevard Tukwila, WA 98188 Dear Mr. Griffin: RE: Intergate West Corporate Park Building C Rooftop Units Tukwila, WA The roof, and the entire structure, has been designed to adequately support the roof mounted air handling units. The gravity ind lateral loads (seismic zone 3) have been reviewed in accordance with the I997 edition of the Uniform'Building Code. Reference: Mechanical drawings by Parrott Mechanical, Inc., sheets M0.0 and MI.7, dated Deoember 22, 1999. Roof mounted units Include air handling units AHU -3 (6000 lbs.) and AH1. 1.•1(6000 lbs.) Please call if you have f%mher questions. Sincerely, Robert Bout • g President Nelson - Bourdages A Division ofPoggemeyerDesign Group, Inc. CC: Haynes Lund 44to O. eo�RG ,: 4' 1014 Lit ,,,,,,;� NAL� FA/t+B OCTOOEA 8a NELSON- BOURDAGES a Division of fbggemeyer Design Group, inc. 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (4 .5) 627 -5995 • Pax (425) 828.4850 P. 2 REOEMID OITY OP 9UKW U.A JAN 2 0 2001) PERMIT.08NTER VERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M99 -0158 DATE: 1 -13 -2000 PROJECT NAME: INTERNATIONAL GATEWAY CORP Original Plan Submittal Response to Incomplete. Letter # Response to Correction Letter # _ XX Revision # 1_ BeforePermit Is Issued DEPARTMENTS: AvilE Div(s1543 Public Works Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 1 -18 -2000 Not Applicable n Comments: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved DUE DATE 2- 15-2000 Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: U'RROUTE.DOC 5/99 S4" 4'CC PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER M99 -0158 DATE 8 -11 -99 PROJECT NAME : PACIFIC VIEW OFFICE "C" X Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # _Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works n Fire ifeqntion Awe- Y-01? Structural Planning Division Permit Coordinator s DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 8-12 -99 Not Applicable TUES /THURS ROUTING: Please Route g Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions DUE DATE 9 -9 -99 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: \PRROUTE.DOC 5/99 City of Tukwila, • Department of Community Development John W.'Rants, Mayor Steve Lancaster, Director 4 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, eta Date: / Plan Check/Permit Number ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued "G? e to p hone CzylvcrGl ji On. Project Name: 6 /t' '-- Project Address: /2 /L,/ / [1 A tom/ i/A,K Contact Person: t / , Phone Number: 7 5 3 "17/©6-^V Summary of Revision: G I 111 JAN 2 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: Entered in Sierra on 1' °ail'' 06/29/99 _Agnagnutbr__enter_Boulevard Suite #100 • Tukwila, Washington 98188 • 1206) 4313670 • Fax (206) 4313665 City of Tukwila John W Rants, Mayor Department of Community Development Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: \ Plan Check/Permit Number: M q 01 8 O Response to Incomplete Letter # • Response to Correction Letter # O Revision # after Permit is Issued Project Name: U1N c-V c 34? \ ('Th-VOso -)�,� �8� Project Address: 1Z-/0/ f 1 L t fo Contact Person: t (l Cti lgN) Phone Number: ? '� gag ~%g24 Summ. of Revisi• : 2-- Voo 'be •%& M l op TUNWIU1 JAN 1 3 2000 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision ` Received at the City of Tukwila Permit Center by: t 1, �(�tvnI (/ — Entered in Sierra on L— l �� 2-00 06/29/99 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 City of Tukwila Fire Department Fire Department Review Control #M99 -0158 (512) John W. Rants, Mayor Thomas P. Keefe, Fire Chief August 13, 1999 Re: Pacific View Office Park Building #C - 12101 Tukwila Intl. Blvd. Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto- shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 2 John W Rants, Mayor Thomas P. Keefe, Fire Chief obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 3. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) .57$4439 F625-052-000 (8/97) • -A. DEPARTMENT OF LABOlt AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL 4ARROTT MECHANICAL INC 6600 N GOVERNMENT WY COEUR D'ALENE ID .83815 I: \ANCHQRS \CABLE \UNIT\SLC75 \YCD480 v1. W. SAUSSE & CO., I `C. VALENCIA, CALIFORNIA 91355 CONSUL TING ENGINEERS 1 X S AIRCRAFT CABLE W/ (3) U- CLAMPS 9 EACH END. PROVIDE THIMBLES 9 LOOPS 9 INSTALL HAND TAUT WITHOUT SLACK JOB NAME SABEY OFFICE BUILDING CUST: BULLOCK TRANE COST P.O.: VI -10551 MECH.. ENGR.: 140 ± UNIT BASE OUTLINE ANCHORAGE LAYOUT CONDENSER SECTION FOR DETAIL SEE DWCs. " 2A REWSIONS :: A: UNIT'ADDED(I0- 12 -SS) B: 92± UNIT LIFTING LUG (4) PLACES SCALE.. DRN: PPG I CHK.: DATE 9 -1 -99 SHEET NO: - „^ Isis STRUCTURAL SUPPORT STEEL f— BT OTHERS) PL. 3 X 5 X 3/8 / 3/16 NOTES: 1) ADEQUACY OF STRUCTURAL STEEL SUPPORT MUST BE VERIFIED BY OTHERS. ✓E SABEY OFFICE BUILDING M.W. SAUSSE & CO., 11\ C. COST: OB NAM BULLOCK TRANE VALENCIA, CALIFORNIA 91355 GUST. P.O.: VI -10551 lB I YPE C(�ABLE I ENGR •: FALTA /BRAGS RF.JTIINT TRANE YCD 480, TED 480 Tc= 4580 lbs. FOR TRANE TED 480: USE 3/5' DIA. CABLE Tc= 4890 lbs. FOR TRANE YCD 450: USE 1/16' DIA CABLE Al REVISIONS: A: UNIT ADDED(10 -12 -99) 8: 1 X19 AIRCRAFT CABLE W/ (3) U- CLAMPS — ENDS. PROVIDE THIMBLES e LOOPS 4 INSTALL HAND TAUT WITHOUT SLACK DRN: PPG DATE 10 -1 -99 SHEET NO.: 26296 -2A JOE NAME SABEY OFFICE BUILDING M. W. SAUSSE' & CO., INC. OUST.: BULLOCK TRANE PREPARED BY PDG MECH. ENGR.: DATE DO-Oct-96 MARK: TRANE YCD 480 SHEET NO. 26296 -C1A CALCULATIONS FOR CABLE BRACING. UNIT CALC'S 8 CABLES 4P vIELLL 'CABLES . \ 1Y ?. r . / J /I /I`. PLAN AEU). AIR CRAFT CABLES: (ASSUME ALL OF FpH RESISTED BY TWO CABLES) T cable:FpH "2 ^.5/2 = 4887.36 Dyable MIN: 0.4375 7 X 19 AIR CRAFT CABLE' NAP HORIZONTAL SEISMIC FORCE: 32 -1: FpH= 4"Caip "Wp /1.4 (MAX) 6911.77 32 -2: FpH =(apCalp /Rp)(1 +3hx/hr)Wp /1.4 = 11519.62 32- 3:FpH =0.7"Ca "Ip°Wp /1.4 (MIN) = 1209.56 CONTROLLING HOR. SEISMIC FORCE: FpH = 6911.77 SUPPLEMENTAL VERT. SEISM. FORCE: FpV = 0.00 SEISMIC ZONE: Ca = 0.44 IMPORTANCE FACTOR: Ip = 1.00 COMPONENT AMPLIFICATION FACTOR:ap = 2.50 COMP. RESPONSE MODIFICATION FACTOR: Rp = 1.50 EQUIPMENT ELEV. / ROOF ELEVATION: hx/hr = 1.00 ( WITH RESPECT TO GRADE) EQUIPMENT WEIGHT: Wp = 5498.00 L: = 140.00 5: = 92.00 EXPIRES x:.281 V1 JOE NAME SABEY OFFICE BUILDING ' M. W. SAUSSE' & CO., INC. CUST.: BULLOCK TRANE PREPARED BY : PPG MECH. ENGR.: DATE 09- Oct -9' MARK: TRA.NE TED 480 SHEET NO. : 26296 -C2A CALCULATIONS FOR CABLE BRACING. UNIT CALC'S 8 CABLES AIR CRAFT CABLES: (ASSUME ALL OF FpH RESISTED BY TWO CABLES) T cable:FpH •2 ^.5/2 = 4571.79 D cable MIN: 0.3750 7X 19 AIR CRAFT CABLE AA Cr?.., ty5R HORIZONTAL SEISMIC FORCE: 32 -1: FpH =4 "Ca "Ip*Wp /1.4 (MAX) = 6465.49 32 -2: FpH = (apCalp /Rp)(1 +3hx/hr)Wp /1.4 = 10775.81 32- 3:FpH =0.7 "Ca'I1fWp /1.4 (MIN) = 1131.46 CONTROLLING NOR. SEISMIC FORCE: FpH = 6465.49 " SUPPLEMENTAL VERT. SEISM. FORCE: FpV = 0.00 SEISMIC ZONE: Ca = 0.44 IMPORTANCE FACTOR: Ip = 1.00 COMPONENT AMPLIFICATION FACT ACTOR:ap = 2.50 COMP. RESPONSE MODIFICATION FACTOR: Rp = 1,50 EQUIPMENT ELEV. / ROOF ELEVATION: hx/hr = 1.00 ( WITH RESPECT TO GRADE) EQUIPMENT WEIGHT: Wp = 5143.00 L: = 14-0.00 8: = 92.00 J05 NAME: SABEY OFFICE BUILDING I 11'I.N!. SAUSSE' & CO., INC. CUST.: BULLOCK TEASE PREPARED BY : PPG ENGR: DATE : 09-Oct 99 UNIT MARK: CRANE YCD 480, TED 480 SHEET NO. 26296 -C3 Tc= 458015s. FOR T RANE TED 480 Tc= 4890 lbs. FOR TRANS' CD 480 Tc 3 Vp = Fph -�--F .4 � n } r STRUCTURAL SUPPORT STEEL (Br OTHERS) x -Axi5 CHECKING FOR WELD, BASE PLATE: Sw: d ^2/3 = 2133 Plate thickness (t) Plate width: w where: M = Tp'L /4 b: 6.00 fb= M'6 /(w't ^2)kei d: = 8.00 Area of weld, A = d'2 fbw= M /Sw fvw = Vp /A ftw = Vp / A fw = ((fbw + ftw) ^2 + fvw ^2) ^0.5 Weld size: n = fw /450 Per 1/16" fillet \II II Tp =Fph: (Tc /2 ^.5) = 3457.75 Vp =Fpv: (Tc/2".5) = 3457.75 CHECKING FOR VERT. PLATE SIZE rr Try plate size : 3 X 5 (lenght), L = 0.38 / lu % Plate thickness (t) = 3.00 M =Vp'1.5 = 5186.63 fb= M'6 /(L't ^2) = 9.10 fv =ft= Vp /(t' L) ksi = 3.03 Tp = Fpv FL. 3 X S X 3/0 USE 3/16" FILLET WELD 50TH 51DES OF BASE PLATE 16.00 324.16 216.11 216.11 581.89 1.29 Tension in cable (Tc) = 4890.00 (For 1:1 slope of cable) O.K. Per inspectionl I USE PLATE S /8X3X5 CHECKING FOR WELD 51 VERT. PLATE: 5w: d ^2/6 where :61 Area of weld, A =d'2 flee = M / Sw = 1244.79 fvw = Vp / A = 345.78 ftw = Vp / A = 345.78 fw = ((fbw + ftw) ^ 2 + fvw ^ 2)^ 0.5 = 1627.72 Weld size: n = fw /450 Per 1/16" fillet = 3.62 U5E 1/4 "FILLET WELD 50TH SITES OF VERTICAL PLATE CHECKING FOR SASE PL ,TE SIZE TRY 6X PLATE Plate lenght: L 4.17 5.00 10.00 8.00 0.50 6.00 = 6915.50 27.66 ROOF TOP UNITS UNIT MANUF. MODEL SERVES CFM S/A CFM OSA COOLING TOTAL BTU HEATING TOTAL BTU VOLTAGE MCA WEIGHT NOTES RTU -3 TRANS TED480A4 3d FLOOR '. 16,000. 1,600 480,000 54 KW 460/3/60 225 MCA 6,000 Pus. PROVIDE WITH ISOLATION CURBS, ECONOMIZER, POWERED EXHUAST, INLET GUIDE VALVES OR VFD (TBD). RTU-4 TRANE TED480A4 41h FLOOR 16,000 1,600 480,000 '' 54 KW 460/3/60 225 MCA 6,000lbs. PROVIDE WITH ISOLATION CURBS, ECONOMIZER, POWERED EXHUAST, INLET GUIDE VALVES OR VFD (TBD). ELECTRIC WALL HEATERS UNIT MANUF. MODEL LOCATION HEATING VOLTAGE NOTES EWH-1 ■ MARKEL F3422 SEE PLANS 2 KW 277/60/3 ELECTRIC WALL HEATER WITH INTEGRAL T -STAT UNIT MANUF. MODEL VOLUME SP FRPM TIPSPEED HP- VOLTAGE ENCLOSURE RPM Lwa ABA SONES NOTES EF -1 GREENHECK 0-170 -B 2894 .35 1140 5362 112 115/60/1 ODP 1140 79 67 16.6 COMMON EXHAUST; WITH ROOF CURB & BDD EF -2 GREENHECK SBE- 2L24 -7 4875 .3 884 5554 3/4 460 /60/3 ODP 1725 77 66 16.6 PARKING GARAGE EXHAUST FAN; MONOXIDE DETECTOR BY ELECTRICIAN EF -3 GREENHECK SBE- 2L24 -7 4875. .3 884 5554 3/4 460/60/3 ODP 1725 77 66 16.6 PARKING GARAGE EXHAUST FAN; MONOXIDE DETECTOR BY ELECTRICIAN EF-4 GREENHECK SBE- 2L24 -7 4875 .3 884 5554 314 460/60/3 ODP 1725 77 66 16.6 PARKING GARAGE EXHAUST FAN; MONOXIDE DETECTOR BY ELECTRICIAN EF -5 GREENHECK SBE- 2L24 -7 4875 .3 884 5554 314 460/60/3 ODP 1725 77 66 16.6 PARKING GARAGE EXHAUST FAN; MONOXIDE DETECTOR BY ELECTRICIAN EF-6 GREENHECK SE7- 10-428 -P -1 273 .25 1650 4320. 1/30 115/60/1 TEAO 1650 69 57 10.2 SERVES ELECTRICAL ROOM ON P2 EF -7 GREENHECK SE1- 121 -432 -D8 891 .35 1550 4869. 1/8 115/60/1 TEAO 1550 70 59 10.2 SERVES ELEVATOR PENTHOUSE SYMBOL LEGEND SYMBOL DESCRIPTION i 0 IIIIIIIIIIIIIIIIIIIIIIIIIIII UPI �Ih - RG- RL - HWS- -HWR- -CWS- -CWR- D CEILING SUPPLY DIFFUSER CEILING RETURN REGISTER CEILING EXHAUST GRILLE SIDEWALL SUPPLY REGISTER VANED ELBOW OR MITERED ELBOW RETURN AIR OR EXHAUST DUCT THRU LOWER OR UPPER LEVEL SUPPLY AIR DUCT THRU LOWER OR UPPER LEVEL ROUND DUCT THRU LOWER OR UPPER LEVEL ROUND FLEXIBLE DUCT DUCT WITH INTERIOR ACOUSTICAL LINING (A.L.)- INSIDE DIMENSION DROP IN DUCT IN DIRECTION OF AIR FLOW DROP IN DUCT IN DIRECTION OF AIR FLOW DUCT WIDTH BY DEPTH IN INCHES DUCT ACCESS DOOR ROOM THERMOSTAT (ELECTRIC) VOLUME DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER COMB. FIRE/SMOKE DAMPER FIRE DAMPER CEILING RADIATION DAMPER DUCT SMOKE DETECTOR S/A WALL REGISTER W/ CFM LISTED S/A DIFFUSER W/ CFM LISTED REFRIGERANT. GAS (SUPPLY) REFRIGERANT LIQUID (RETURN) HEATING WATER SUPPLY HEATING WATER RETURN CHILLED WATER RETURN CHILLED. WATER RETURN DRAIN LINE GENERAL NOTES DUCT SIZES INDICATED ON PLANS ARE INSIDE DIMENSION. MATERIAL IN RETURN AIR PLENUMS TO BE FIRE RATED. OTHER TRADES SHALL NOT HANG OR SUPPORT EQUIPMENT, CEILING WIRES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT OR DUCTWORK. FINAL PAINTING OF GRILLES, REGISTERS, AND DIFFUSERS, AS MAY BE REQUIRED BY ARCHITECT, SHALL BE DONE BY GENERAL CONTRACTOR. FIRE DAMPER ALL CEILING PENETRATIONS PER U.B.C. SECTION 710. INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF SHAFT ENCLOSURES PER U.B.C. SECTION 711 INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF AREA OR OCCUPANCY SEPARATION WALLS PER U.B.C. SECTION 713 INSTALL COMBINATION SMOKE F.itE DAMPERS AT ALL PENETRATIONS OF HORIZONTAL EXIT WALLS AND CORRIDORS PER!J.B.C. SECTION 713. INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF SMOKE BARRIERS PER U.B.C. SECTION 713 ALL FIRE DAMPERS SHALL BE DYNAMIC TYPE, U.L. 555 RATED. ALL CEILING RADIATION DAMPERS SHALL BE U.L. 5550 RATED. ALL COMBINATION SMOKE FIRE DAMPERS SHALL BE U.L. 555S RATED. INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER U.B.C. REQUIREMENTS. INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE AND OTHER TRADES: PROJECT NOTES 2. THIS DESIGN IS FOR CORE /SHELL WORK ONLY. TO INCLUDE THE FOLLOWING: PARKING GARAGE LEVELS 1 & 2, EXHAUST ONLY FOR 1st AND 2nd LEVELS, EXHAUST AND RTU'S WITH MAIN SHAFT DROPS FOR 3rd AND 4th FLOORS. ADDITIONAL SUBMITTAL WILL BE REQUIRED FOR TENANT IMPROVEMENT AND ANY ADDITIONAL WORK TO THE CITY OF TUKWILLA FOR REVIEW /APPROVAL. 1. ALL HVAC UNITS ABOVE 2,000 CFM CAPACITY TO BE EQUIPPED WITH SMOKE DETECTORS IN DUCT. A I I I D I E H PERMIT SET EXHAUST FANS FILE COPY I undersrand that the Elan Check approvals are suTIect to errors and omissions and approval of plans does not authorize the violation fieon- ::I,)Ytee code or ordlnence.R of o n- 1raclor's copy iapProv� plans tq By Date Permit TIC 0 - 0159 le V6; OS o�c I . Wvti DRAWIN .ESCR PTIO DRAWING INDEX MO.0 SCHEDULES AND SHEET INDEX M1.1 M1.2 M1.3 M1.4 M1.5 M1.6 M1.7 PARKING LEVEL 2 PARKING LEVEL 1 FIRST FLOOR PLAN SECOND FLOOR PLAN THIRD FLOOR PLAN FOURTH. FLOOR PLAN ROOF PLAN RECEIVED CITY OF TUKWIL? JAN 1 3 2000 PERMIT CENTER di'I Mechanical Incorporated 6600 N. GOVERNMENT WAY ?EU° OALENE, 8( oc li5 (288) 7 '2 -: 16S G -no (278) 7 /241:i1 FAX di'i ott Mechanical Incorporated 6600 N. GOVERNMENT WAY COEUR D'ALENE, 83815 (208) 772 -5165 Phone (208)772 -6151 FAX Seivice Everts ERN PARROTT PROJECT NO SHEET NO: MONO 1 OF 9 3 O r • a> 1 =— I — — M.\\I h.k■ 4D b Z W 0e rr 171 177 z r o if AA Z ■ A r z PARKING LEVEL P2 HVAC PLAN _- BUILDING C INTERNATIONAL GATEWAY CORP. PARK PACIFIC HIGHWAY S. TUKWILLA, WA 1 L I I I I I I I I - 11 11 I I I I I I 11 u M 99 - D / 58 EaF ri ARCHITECT: SABEY CORPORATION ARCHITECTURE GROUP MECHANICAL ENGINEER: PARROTT MECHANICAL ENGINEERING GROUP GENERAL CONTRACTOR SABEY CORPORATION GENERAL LOCATION MECHANICAL CONTRACTOR: PARR07T MECHANICAL cJ E DATE: NO. BY REVISIONS HON „-° 6 (:) 7 PARKING LEVEL P1 HVAC PLAN BUILDING C INTERNATIONAL GATEWAY CORP. PARK PACIFIC HIGHWAY S. TUKWILLA, WA I ,AqQm 9f C ARCHITECT: MEET CORPOFtATION ARCHFIEC tURE GROUP MECHANICAL ENGINEER: PARROTF MECHANICAL ENGINEERING GROUP GENERAL CONTRACTOR: GABE, CORPOFtATION GENERAL LOCATION MECHANIC. CONTRACTOR: PARROTT MECHANIC. ff m 2 0 ?: NINON 1 BUILDING C INTERNATIONAL GATEWAY CORP. PARK PACIFIC HIGHWAY S. TUKWILLA, WA FIRST FLOOR HVAC PLAN Alk9 9 otiq E7 4111 111111111, -11 111 Pw` 11_* 1 10111111a JAM ARCHITECT: SABEY CORPORATION ARCHII ECTUREGROUP MECHANIC, ENGINEER: PARROTT MECHANICAL ENGINEERING GROUP GENERAL CONTRACTOR: SABEY CORPORATION GENERAL LOCATION MECHANIC, CONTRACTOR: PARROTT MECHANIC, 1 0 clOPOit Mechanical Incorporated 6600 N. GOVERNMENT WAY '08;'772-5I6IE7085 (208)772-6151 FAX G Pei 100 AZI■ NTZ', ,L ELECTRICAL DESIGN FOR THIS FLOOR CONTAINS EXHAUST DUCTWORK ONLY. HEATING/AC UNDER TO BE PROVIDE UNDER SEPARATE PERMIT FOR THIS WORK. VESTIBULE VESTIBULE Irosi I LE/ LOBBY I r2o2 k JL iN11111111' ROO I r.:. I 72.1 DESIGN FOR THIS FLOOR CONTAINS EXHAUST DUCTWORK ONLY. HEATING/AC UNDER TO BE PROVIDE UNDER SEPARATE PERMIT FOR THIS WORK. LJ IGCP - BUILDING "C" SECOND FLOOR HVAC PLAN SCALE: 1/8" = 1 ,F1 SCALE: 115 =1 ne 0 4 8' 16' PERMIT SET cli &oil Mechanical Incorporated 6600 N. GOVERNMENT WAY COEUR D'ALENE. ID 83815 (208) 772-5165 Phone (208) 772-6151 FAX ..7P7 sui.ow Aim &per& MN MIN A Service ExpeiisSompany r=circ =OF r HMICA PARROTT PROJECT NO: SHEET NO: M154 32' 5 OF 9 A 0 0 0 LOBBY ELECTRICAL ROOM A ELECTRI DESIGN FOR THIS FLOOR CONTAINS "CORE" WORK ONLY. WHICH CONSISTS OF RTU DROPS AND EXHAUST DUCTWORK. TENANT DUCTWORK LAYOUT TO BE PROVIDE UNDER SEPARATE PERMIT. f4-- - - - - - - - AEI SCALE: El El- IGCP - BUILDING "C" THIRD FLOOR HVAC PLAN IT 547.26 S/A FROM RTU-3 WITH FSD DESIGN FOR THIS FLOOR CONTAINS "CORE" WORK ONLY. WHICH CONSISTS OF RTU DROPS AND EXHAUST DUCTWORK. TENANT DUCTWORK LAYOUT TO BE PROVIDE UNDER SEPARATE PERMIT. El SCALE: 1/8" = 1O, 0 4' 8' 16' PERMIT SET onVga■L4 JAN 1 3 2000 PERMIT CENTER Mechanical Incorporated 6800 N. GOVERNMENT WAY COEUR DIAL.ENE, ID 83815 pow 772-5165 Phone (208) 772-6151 FAX 9 5 ; O 11 a eat 0: 0 C) CD i- < -J z ° o P _z z -I in = Mechanical Incorporated /205 77 25165 Phone ,(208) 772-6151 FAX apes moor SeMera mannowsl Ear A Service Experts Company T=3"1 2r=",=tur71=="gs'a PARROTT MECIONICAL SHEET NO: M 5 32 6 OF 9 A Lr ELEC. ROOM 7Ex 15 DESIGN FOR THIS FLOOR CONTAINS "CORE" WORK ONLY. WHICH CONSISTS OF RTU DROPS AND EXHAUST DUCTWORK. TENANT DUCTWORK LAYOUT TO BE PROVIDE UNDER SEPARATE PERMIT. r''G I _ 9 TELE/DATA riZir LOBB I F402 , I r " \ It ; I i 2 11 0 .= d t-) IL ; FO • C. Hk SIA UP TO AHU-4 FOR 4th FLOOR_ 54x26 S., DOWN FROM AHU-1 FOR 4th FLOOR IGCP - BUILDING "C" FOURTH FLOOR HVAC PLAN 54,26 SA DOWN FROM AHLI-3 FOR 31d FLOOR. F ) 1a-1 I ( L 9 54x26 LEC. ROOM EXH 54x26 SA DOWN CHASE TO 3rd FLOOR CHAS DESIGN FOR THIS FLOOR CONTAINS "CORE" WORK ONLY. WHICH CONSISTS OF RTU DROPS AND EXHAUST DUCTWORK. TENANT DUCTWORK LAYOUT TO BE PROVIDE UNDER SEPARATE PERMIT. . 1 - - FLA voysfN 1 TO 3F FLOOR TXIR'NAY I F4'4 I .1.1 1 1 1 PERMIT SET cgiMPA„,,A JAN.1 3 2000 PERMIT CENTER arehoil Mechanical Incorporated 6600 N. GOVERNMENT WAY ' N . , ‘ )172 . - A 5 1- 1 E 6 ' 5 ' h ne (208)772-6151 FAX I 0 PARROTT PROJECT NO: SHEET NO: M lo 6 k ) Mechanical Inoarporated 6600 N. GOVERNMENT VVAY C 2( 073 (208)772-6151 FAX Savice averts AMU A Service Experts Company T o ' n ' Ol=== E or. , ==tano OTI:17 CV de•cAt SCALE: IV 1/8" = 1-0" c , 4 , b. 16' 32' 7 oF 9 cc 0 ckw 0 M 0> u- H1aON O ROOF HVAC PLAN 0, onr i z 700 9 a BUILDING C INTERNATIONAL GATEWAY CORP. PARK PACIFIC HIGHWAY S. TUKWILLA, WA J .ARCHITECT: SAEEY CORPORATION ARCHITECTURE GROUP MECHANICAL ENGINEER: PARROTT MECHANICAL ENGINEERING GROUP GENERAL CONTRACTOR: SABEY CORPORATION GENERAL LOCATION MECHANICAL CONTRACTOR: PARROTT MECHANICAL C) 9' -4" 9' -4" 14' -2" r I3' -0" 15' -0" I5' -O" 2' -0" f' -4" 2 ' -6 " 11' -8" r1' , r 2' -6" 10' -6" 2' -6" 10' -6" 2' -6" I2' -6" , / r1' rr o r m� W -p15 BUILDING ELEVATIONS • t BUILDING C INTERNATIONAL GATEWAY CORP. PARK PACIFIC HIGHWAY S. TUKWILLA, WA 2' -6" ARCHITECT: SAUEY CORPORATION ARCHITECTURE GROUP MECHANICAL ENGINEER: PARROTT MECHANICAL ENGINEERING GROUP GENERAL CONTRACTOR: SABEY CORPORATION GENERAL LOCATION MECHANICAL CONTRACTOR: PARR:, MECIWSCAL DATE: RE,SIONS