Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M99-0197 - CULLIGAN WATER
M99 -0197 51:A < xFx, td 18404 Cascade Ave. So. Culligan Water City of Tukwila II Permit No: M99 -0197 Type: B -MECH Category: NRES Address: 18404 CASCADE AV S Location: Parcel #: 788890 -0020 Contractor License No: MERITMI163CM * * ** Per MECHANICAL PERMIT (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Status: ISSUED Issued: 10/26/1999 Expires: 04/23/2000 TENANT CULLIGAN WATER Phone: 18404 CASCADE AV S. TUKWILA, WA 98188 OWNER ESTATE OF JAMES CAMPBELL Phone: (206)872 -4680 C/0 COLLIERS INTERNATIONAL, 20206 72ND AVE S, KENT WA 98032 CONTACT JOHN SKOOG Phone: 425 -883 -9224 9630 - 153 AV NE, REDMOND, WA 98052 CONTRACTOR MERIT MECHANICAL INC. Phone: 206 883 -9224 9630 153RD AVENUE N.E., REDMOND, WA 98052 **** ** * *** *** * *** * * ** * ** * * * **** k * * * * * ** k* k ** * * ** ** * * * * * *rl ** ** * * * ** * ** ** *** Permit Description: (1) GAS FIRED FURNACE, (1) EXHAUST FAN - BOTTLE ROOM. UMC Edition: 1997 Valuation: 4,000.00 Total Permit Fee: 75.06 * * * * * * * * * * * ** ************************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Cente, horized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or e performance of work. I am authorized to sign for and obtain this ui ng permit. Signature: � --i `"'{ Date: / - Z.6 -9 2. Print Name: g (. t: Title: 6 1 -4 101- i.r / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF •TUKWILA Address: 18404 CASCADE AV 5 Suite: Tenant: CULLIGAN WATER Status: ISSUED Type: B-MECH Applied: 10/14/1999 Parcel It 788890 -0020 Issued: 10/26/1999 •k * * *•k **k* *** * *•k *•k * **•k* * * * * * * * *•k** * * ** A **•k ** k**** * * *** * *•*•k *•k* *** * * *•k Permit Conditions: 1 , . No changes w i l l be made to the plans unless approved by the Engineer and the Tukwila Building :. Division. 2. All permits, inspection reco " , and" approved plans shall be available at the Job site prior to the start of any con - struction. These '"'documents are to be maintained and avail- able until final inspection approval is granted 3. All construction to :be "'done in "conformance with approved plans and requirements of the : Uniform Building Code = (1997 Edition) as amended Uniform Mechanical' Code (1997 Edition), and Washington State Energy Code (1997 Edition). 4. Validity of Permit." The issuance of a permit. or approval. plans, specifications. and computations shall not ' "be..con = =' strued: to be a permit for, or an. approval of, any .violation':.` of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate Or cancel the provisions 01- thls r' code shall be v a l i d . 5. Manufacturers installation :instructi`ons' required on site for the .»building "inspectors ".,review. ." Permit No: M99 -0197 e - Project Name/Tenant: 1.a 44.4 — '- Fes'! Valu t Co struction: Will there be storage o flammable /com ustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on se•arate 8 1/2 X 11 •a•erindicalln• •uantlties & Material alel Data Sheets Site Address: . An/ •. e City State /Zip: GIBE. 1 F if U'E " ` V` IuA. 4PJ Tax Parcel tuber: 1 f it , Property r: r_. ear LsJE1. w1iD� e Iwlf r Phone: �� g��� Fax #: Street Address: Zp2..040 '2140 Atie. • <°70 . City State /Zip: v-.44- 1 kl.a. 4 P c Contact Person: � � Ph �$� .� 97 _ _ / �r7�— Street Ad �z�p �5.�,/E,,. f J . City State /Zip: �c�.�iD �ll�r 5. 4 +S Fax #: 0 Sewer Contractor: IwE t i tc4e�t_, 0.1C. Phon Z erg 1 2+ Street Address:C�( iC� 10 4 1 te C ^( , 'Z City State /Zip: Fax #: Architect: L -. Pho�e� 5 Fax #�: -' ' � t �(' Q Street Address: 2:2— -- 1 'tf: 2 4. r City State /Zip: 1J- VL)E.1 I),sSIL Q & Engineer: ILG4&L_.1 (f [.. s Ph 9-e27-7- L 224 /P--C, /1 4e. Street Addressq( ( Vj��� City State /Zip: Fax #: 1. � MISCELLANEOUS: PERMIT'REVIEW AND' APPROVAL•. REQUESTED: (TO -BE FILLE©; Descr' Lion of work to be done: 1.2.440 ( 1 Will there be storage o flammable /com ustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on se•arate 8 1/2 X 11 •a•erindicalln• •uantlties & Material alel Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead/Docks ■ Commercial Reroof CI Demolition ❑ Fence R Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls Temporary Pedestrian Protection/Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF 1WKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. • APPLICANT:REQUEST FOR MISCELLANEOUS PUBLIC 'WORKS PERMITS:`: ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. lt.grading/clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer #• ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity' gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: Phone: City /State /Zip: 4 Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is sybJect to possible revision by the Permit Center to comply with current fee schedules. • Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale ap plication - ac 1 c 11 4 Dgo Appll atlon n gals) BUILDING 0:Lb,: • O • '�� ORIZED'AGENT: SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water.Tanks - Supported directly upon grade • exceeding 5,000 gallons and a ratio of height to diameter. Qr width which•exceeds 2 :1 . < Signature: `) `(Alg• �,y Date: (v _ i 4, . • Print name :Mr ......b",4 C le_cznes. • Fax #: Fax Address: T! 0 Z t /State /Z p , QM0,l17 ^2104 il SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water.Tanks - Supported directly upon grade • exceeding 5,000 gallons and a ratio of height to diameter. Qr width which•exceeds 2 :1 . < PERMIT REVIEW Submit No Mg : Antennas /Satellite Dishes,. , Submit checklist: _No. M -1:.. Awnings /Canopies : -- No:signage Commercial Tenant Improvement Permit Bulkhead/Dock ; ; Submit checklist No:, M -10. rl Commercial Reroof Submit checklist No •M -6 Demolition : ' Submit checklist Not M ::: M -3a Fences - Over 6 in'Height Submit checklist. Nix' M =9' 0 Lend•Altering/Grading/Preloads: Sjibmit checkii4t' iJo :.M -2.. J Loading:Docks Y; :. mmercial T'enant1niprovement ,,; • Co Permit.<: Su c ec s No:' H 17. bruit 'h '"kli f 1 , '" � Mechanical�(Residential' &•Commercial). , YV ' ',Submit checklist: • No:,, M 8, `, Rgsidential;only -:H =6, 171.16: Miscellaneous Public Works Permits i; S ubmit;ch'ecklist . No H-9 ® Manufactured Housing (RED INSIGNIA ONLY) checklist No: M -5 El Moving Oversized: Load /Hauling Submit checklist No: M-5 J Parking Lots Submit checklist No: M - 4 .. 0 Residential Reroof - Exempt with following exception: :If roof structure to'be.repaired or replaced . Residential Building Permit Submit checklist .. No:. M -6 El Retaining Walls - .Over ' feet in height Submit checklist No M -1 El Temporary Submit checklist . No: M -7 .. .. 0 Teinporary'Pedestrian Protection/Exit`Systems, Submit checklist No: M - CI Tree Cutting Submit checklist : No: M-2 ALL MISCELLANEOUS PER APPLICATIONS MUST BE SUBM( /. WITH THE FOLLOWING: ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN !t. ° !" *. " BylLOI sin PL UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building'Owner /Authorized Agent if the applicant is other than the.owner, registered architect/engineer,:or contractor ilcensed by the State of Washington,. a notarized letter from•the property, owner authorizing the agent to submit this permit appllcatlon and obtain the permit will be required •as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. , 1 ..., , M M1 SOP11r ' ,i " SC? ' 7 {11 • ✓ Working Drawings Fl or plan System layout • El ations (for roof mounted equipment) and proposed screening - Heat Loss Calculations Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504(e)) H,V.A.C, over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut -off and will be routed to the Fire Prevention division for additional comments, code section Uniform Mechanical code 100A. ✓ Document Requirements Documentation or specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Ener• Code. Structural engineer's analysis is required to replace existing roof equipment weighing 400 pounds and greater (Uniform Mechanical Code Section 2336(a)) Water heaters and vents are included in the UMC - please include any water heaters or vents being installed or replaced. Structural calculations stamped by a Washington State licensed Structural Engineer shall be required if structural work Is to be done Miscellaneous Permits COMMERCIAL: Four complete sets of drawings and attachments required with MAR 03 '98 03 :20PM TWVILA DCD /PW CITY OF :UKW!LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 RESIDENTIAL: Four complete sets of drawings and attachments required with application submittal Working Drawings On 8 1/2 x 11 sheet of paper include the following: Narrative of work to be done (i.e., changeout, replace existing equipment, modifications, etc.) Type of unit being installed Rating /Size Number of units MECHANICAL PERMIT Provide 2 sets of manufacturer's installation instructions P.2 Si M-8 Submittal Checklist Note; Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced _ SD Orr a OF TUKWILA IOCT 41999 ++»*+A+k++*^+^ %?Y 0F TUKW%LA. NH Account Cl ue 000/345~830 00013n.100 .%? 0F UKN%LA NH ~. - TRAN9NIl ,a*+o^� TRANSMIT Number: k9900177 Amount: Pxvmeot Method: CH[CK Nokat,un; M[RI' MECHANICAL %nIt: 108 Permit Ao: M99~0197 Tvpo'z 8-MECN MECHANICAL y[OMIy ;rce! No: 78809O-002O Site Hddroey: 18404 CASCADE AV S TutAl Fpps: 75,06` Thia Pti.vment /5.06 Toto\ ALL Pmts:: 75.06 . Dalancp: .00. +**0*+a*++ Des,riutiun AmouUi PLAN: CHECK ~ NONRES 15.01 MECHANICAL - AO�KEG 8O,0� 75^0G 10/26/99 15:35 ` 0292 10/27 7'�`� ��J5� 6 !�� �-_ `. �i91 t 1 .i) /eh* Type ion: f Aje 4-5 Date called: Special instructions: Date wanted: 1 m. . tzlz. r p.m Requester: Phone:Jl ..... GT .3. 9� zi. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes, INSPECTION RECORD Retain a copy with permit (206)431 -3670 Corrections required prior to approval. COMMENTS: pi k. 7o ,ir1�C )2",‘A, $47,00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Receipt No: Date: COMMENTS: Type �nsf�e�t'on: �� f xe Ow et ati .e. Date called: ,..2 ?J /99 /11456 , f2 Date wanted: a.m. yagir/9a / P.m. Requester: ;if Phone: ll , & -? ..1 / /SF 2 X 7 .5.1 7 a' tt-74' r .(p /2 ' 7 .4 7 -9 ,eer"6 1/ 6 7e-e.5. /O:z A 7l z" /a/ of X./C/4 .-'- frtA9,,e s (A/ //2/ !/�`:r(. r ,/1 77,777C_ AA/ , d P oj / ,,j ,i1.1 /.� Type �nsf�e�t'on: �� f xe Ow et ati .e. Date called: ,..2 ?J /99 Special instructions: y arr Date wanted: a.m. yagir/9a / P.m. Requester: ;if Phone: ll , & -? 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 PERMIT NO. (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: COMMENTS: w , , /� �' (3 etiazip582,1,-.704, AddrQss� e CI. ri ' / 7?ez es Date called: / / ve st! 06/,.57 C::3'?' //s-- �!/ S7X /V v' /—/ 02e. ��i ( k Yee - / / / l 3 Ir .. Requester: Phone: '3- rr /3 .9 Al PPrpjec w , , /� �' Type o Inspectri AddrQss� 6 Date called: /,V M Special instructions: Date wanted: / / l 3 Ir .. Requester: Phone: '3- rr INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. • INSPECTION RECORD Retain a copy with permit PERMIT NO, (206)431 -3670 Corrections required prior to approval. El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: SYSTEM SIZING SUMMARY System: CULLIGAN BOTTLE ROOM Locution: Seattle - Tacoma, Washington Prepared by: Merit Mechanical ITABLE I. SIZING DATA (COOLING) System does not have cooling capabilities. TABLE 2. SIZING DATA (HEATING) Heating Coil Load Ventilation Load Total Zone Load Ventilation Airflow Supply Airflow TABLE 3. INPUT DATA (WEATHER) Supply Ventilation Exhaust FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety 45,097 BTU /hr 31,312 BTU/Iir 13,785 BTU/hr 600 CFM 1,200 CFM Location Seattle- Tacoma, Washington Data Source User Defined Latitude 47.5 Degree Elevation 386.0 ft Atmospheric Clearness ti 1.05 TABLE 4. INPUT (HVAC SYSTEM) System Name CULLIGAN BOTTLE ROOM System Type Warm Mr Iltg Only System Start 6 :00 Duration 24 hrs SIZING SPECIFICATIONS 1,200 CFM 600 CFM 0.00 CFM 0.050 0 0 0% Heating Heating Floor Area Overall U -Value Vent Air Vent Air Block Load 3.05 October 13, 1999 Page: I 53.94 BTU/hr /sgft 1.44 CFM/sqft 836 sqft 0.500 0.72 CFM /sgft 71.77 CFM/Person Sumner Dry-Bulb 84.0 F Coincident Wet -Bulb 65.0 F Daily Range 22.0 F Winter Dry-Bulb 21.0 F THERMOSTAT SETPOINTS Cooling (Occ.) 75,0 F Cooling (Unocc.) 75.0 F lleating 70,0 F RETURN AIR PLENUM No FAN Configuration Blow -Thru Static Pressure 1.50 in. wg. 1TABLE S. TOP TEN COOLING COIL LOADS RECEIVED CITY OP TUKWILA OCT 1 4 1999 PERMIT CENTER ACTIVITY NUMBER: M99-01a19-111 DATE: 10 -14 -99 PROJECT NAME: CULLIGAN WATER Response to Incomplete Letter # XX Original Plan Submittal Response to Correction Letter # — Revision # _ After Permit Is Issued DEPARTMENTS: B Idin 'Division IG-I'' Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route firtev 1PLAN REVIEW /ROUT NG SLIP Incomplete 1 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved U'RROUTE.DOC 5/99 i1/4/0 Fire Prevention Gt io -1Q4q Structural Approved with Conditions n Planning Division Permit Coordinator ‘% 14 No further Review Required DUE DATE: 10 -19 -99 Not Applicable Not Approved (attach comments) DUE DATE 11 -11-99 REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions ❑ Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: F625-0524A) (8197) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST '# CC0100mEgITMI1630004101/20c1 NEFFECTIVEODATE v- MERIT MECHANICAL INC PO' BOX' 2109 REDMOND WA 98073-2109 - • Detach And Display Certificate I certify that this is a true and correct copy of an original license. Notary .].ic in and for the State of Washington residing in Redmond. Recent) CITYOPTuKWILA OCT 1 4 1999 PERMIT CENTER GAS -FIRED FURNACE SCHEDULE SYMBOL LXINRTY GF -1 MAKE 8 MODEL TRAIT TOO 0600936 ESP D5 1200 HEATING NPUT 80 ABA OUTPUT 64 ASH NOTES: t- PRO'DE (1) HEATING ONLY THERMOSTAT W/ FAN ON /OFF CONTROL & INTERLOCK CAPABILITY. WEIGHT IOU AFUE 8102 ELECTRIC:/ 120 WC -1 PH HP 1/3 PROVIDE . DEO ALTER RACK EXHAUST FAN SCHEDULE SYMBOL EF -3 QUANTITY NS RESIRO RESDZOCM 1- (1).. GAS -FIRED FURNACE. 2- (1) EXHAUST FAN.' 3- GAS PIPING. DUCTWORK. 5- GRILLES, REGISTERS & DIFFUSERS. 6- CONTROLS. MAKE &MnEt OAN 360 AN 360 /OWE PRN TUBE CFI 1200 INSTNIATION TO COMPLY WIM APPLICABLE WAWA. KING GAMY AB WASHINGTON STATE CODES. 2 WORM A ANNUM OF 10-G DISTANCE BOWcEN OUTSIDE NR INLETS AID PLUME.. WAWE W]TS, E%IWN T,, 8 COMENS. AlR 3 VEREY IDCATI016 aF THERMOSTATS WHIN OWNER 8 ARCHN[CT. 4 GAS RPM TO RUN BELOW THE ROOF. 5 TENPERAtoK CONTROL ZONING 6 PER TENANT NEWEST. 6 COORDINATE ALL OUCTWCI.. M U915 91111 STRUM/ GRID. UGH. AFB OT ER MAUES. HVAC EQUIPMENT WOKS AND LOCATIONS TO BE APPROVED BY THE STRUCIURA ENGINEER. 8 DUCT SUES SHOWN ARE INSIDE CLEAR DMETSONS. OUCT W. ERR, SPACING, 8 SUPPORT TO BE PER UMC 10 -E&F. 10 PROWDE M/NU/ VOU11E DAMPERS AT ALL SUPPLY BRANCH DUCT. .. ESP 25 .2 SO IlOGHT LES 40 SCOPE OF WORK GENERAL NOTES ELECTRIC/ 120 vk P 120 V PH 1223 V - 1 PH AMPS 0.76 0.70 1/4 HP ACCESSORIES PROVIDE ROOF CURB & BOO NOM STAG. PREWO65LY PER NG, PREVIOUSLY PERMIIp GRILLE, REGISTER AND DIFFUSER SCHEDULE SYMBOL CO -1 RG -' CD -2 EG-1 MIRE SHOEMAKER SHOEMAKER SHOEMAKER SHOSMAN R MODEL 700 MA MA 905 AECK 517E SEE PLAN SEE PLAN SEE PIM SEE P. N ES 1 -897 CEW:G T -BAR CEILING GIP. ED" MANG 41P: BO. GOING EATING, PNEWOUSLY PERMIT. EXISTING PREYDUSLY W.P. LEGAL DESCRIPTION PARCEL. A LDT 1, SOUTHCENTER SOUTH INDUSTRIAL P.C. ACCORDING TO THE PUT THEREOF, RECORDED IN VOLUME 97 OF PUTS, PAGES 22 THROUGH 25, RECORDS OF KING COUNTY: WASHINGTON. PARCELS B. LOT 2 SOUTHCE741Fm SOUTH INDUSTRIAL PARK, ACCORDNG TO THE PUT THEREOF. RECORDED IN VOLUME 97 OF PUTS; PAGES 22 THROUGH 25„ RECORDS OF KING COUNIA: WASHINGTON. PARCEL C. THAT PORTION OF LOTS 3 AND 9, OF THE PUT OF SOUTHCENI., . SOUTH INDUSTRIAL PARK, ACCORDING TO THE PUT THEREOF, RECORDED IN VOLUME 97 OF PUTS, PAGES 22 THROUGH 25, RECORDS OF RING COUNTY, WASHINGTON. LYING EASTERLY OF A LINE DESCRIBED AS FOLLOWS. BEGINNING AT POINT ON THE NORTH UNE OF'SND LOT 3 AT A POINT 240.02 FEET EAST OF THE NORTHWEST CORNER THEREOF OF SAID LOT 9; THENCE SOUTHEASTERLY ALONG A CURVE TO THE LEFT, THE CENTER OF WHIM BEARS NORTH 66'29'49' EAST HAVING A RADIUS OF 459.28 FEET AN ARC DISTANCE OF 245.48 FEET THROUGH A CENTRAL ANGLE OF 30'37'26': THENCE SOUTH 11 WEST, A DISTANCE OF 75.36. FEET TO THE SOUTH UNE OF SAID LOT 9, AND THE TERMINUS OF SAD UNE. TENANT CAS NETER BY OTHERS 430 MBH DEMAND DAMPER (TYPIGA) stePau ON HALL OSTLER WFT W 14X14 EG-I SEE BOTTLE ROOM FLOOR PLAN FOR DUCTWORK IN THIS ARID ES IENP� SPACE F G i Fri � e ati GAS PIPING PLAN SCALE: 1/3T = 1' -T AVON EXISTING ELECT. PANEL & CONDUITS MMHG, GAS BELOW ROOF _OTO L;F -1 O BOTTLE ROOM FLOOR P LAN SCALE: 1 /8 1 WAREHOUSE L EXISTING 1 1/4 GAS 1 ' AC E%IST:vG AC UNR 90 NBH INPUT T.9 MBH OUTPUT 10' -T MIN. o THRU FLUE ROOF 6x16 BALANCING DAMPER (TYPICAL) SUPPORT DUCTWORK ON WALL MOUNT ON WALL /ROVE DOOR 80 MBH INP 60 MFfii JIRUT PUT 0 UP THRU ROOF RD S G OOSENECK & 12X12 SCREENED OPENIN '.W/ BALANCIN G DMPR. EXISTING UNIT HEATER 0 MBH INPUT 80 NBM OUTPUT CONNECT 1' GAS TO EXISTING 7 EXISTING 1 1 /4' GAS EXISTING AC U" 60 MBH INPUT 46.6 NBH OUTPUT EXISTING 1 GAS PERMa i.��ECi.:ICitD OR L:.'.f '%HAN.,CAL r.; RACAL 4oi ANNROVIED 1714q-01 Cl i :2 5 BJ WING DIVISION LT'TY OF 7UN4WU OCT 1 4 1999 PERMITCENTER 1 GAS DN TO GE-1 W/ SHUT -OFF VALVE ® UNIT AA -{U 711E1R -M-0 lk( understand that the Plan Check approvals are subHect to errors and omissions and approval of plane does not authorize the vtoIationft a o ted or ordinance Receipt o c F cudeol approved plan .cknowledged. motor's cop REHM HECHANCAL Wil4oluv Bueineas Park P.O. Box 3396 Redmond, WA. 98078 -3396 (426) 883 -8224 LICENSE: YERIT111163CAA D8EVflSDOROS DIE80OIYIBG JS CHECKED JN DATE 10 -14 -99 JOB HO. 98101 4Q1 .1HApR7 E M- 1 1.1.DWG SHEET HUMBER COPYRIGHT NOTICE THIS LAYOUT/OESIGN IS AN UNPUBLISHED WORK; AND MERIT MECHANICAL' HER.. RESERVES : ITS COMMON LAW RIGHT. PURSUANT TC TITLE 17 SECTION 2 OP THE U.S.A. CODE TO PREVENT ANY UNAUTHORIZED COPYING, F18- UCA71ON OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE.. BUILDING 'A T.I. UUII �.�O�