Loading...
HomeMy WebLinkAboutPermit M99-0206 - WASHBURN PIANO STOREM99 -0206 17334 Southcenter Pkwy. Washburn Piano City of Tukwila ( (206) 431.3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M99 -0206 Type: B -MECH Category: NRES Address: 17334 SOUTHCENTER PY Location: Parcel #: 262304 -9079 Contractor License No: SEAAISM081B9 TENANT WASHBURN PIANO Phone: 17312 SOUTHCENTER PY, TUKWILA, WA 98188 OWNER MBK NORTHWEST Phone: 206 575 -8090 C/O TRAMMEL CROW COMPANY. 17560 SOUTHCENTER PY, TUKWILA WA 98188 CONTACT AL ALDRICH Phone: 206- 575 -8360 2014 136 AV E,.SUMNER, WA 98390 CONTRACTOR SEA -AIRE SHEETMETAL INC. Phone: 206 575 -8360 820 INDUSTRY DR, TUKWILA WA 98188 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: CHANGE OUT ROOF TOP HEAT PUMP 'USING EXISTING ROOF CURB WITH NEW DUCT DROPS AND DUCT SYSTEM PER PLAN. UMC Edition: 1997 Valuation: Total Permit Fee: **** * * * * * * * * * * * * * * *** * * * * * * * * * * * ** *tilt * * * * * * * * ** _ I (� o Permit Cent •r Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. /� Signature: /\ Date: - -- 4/5 MECHANICAL PERMIT Print Name: _4/Y1j./L Title: Status: ISSUED Issued: 11/01/1999 Expires: 04/29/2000 8,600.00 46.50 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 17334 SOUTHCENTER PY Suite: Tenant: WASHBURN PIANO Type: B --MECH Parcel it: 262304 -9079 CITY OF TUKWILA Permit No: M99-0206 Status: ISSUED Applied: 10/25/1999 Issued: 11/01/1999 • kR• k*• k**k*• k*• k• A• k• k• k• k• k• k• k• k• k *•AA *1,•k*k*•k•k•kk•kk•k•k•k*k • k• A* k* Ak*** *k*•AA ***'k•k•k*k'k'AAAA*%*•k Permit Conditions: 1. Readily accessible access to roof mounted equipment is required. 2. No changes will be made to ;the plans':unl•.ess approved by the Engineer and the Tukwila B u i l d i n g D i v i s i o n ` �. All permits, inspection records, and approved plans shall be available at :the' j ob site, prior to' the start of any . con- struction. These documents are to be maintained and avail- able until final inspection:approval,is granted. • 4. All construction to be done in conformance with approved plans and requirements of the Uniform B u i l d i n g ' Code' (1997 Edition):. as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition), 5. Validity of Permit. The issuance of a permit or approval of plans', specifications, and computations shall not be con- strued to be a permit. `for, or an approval of, any violation' ;. of any of the provisions of the building code or of any other ordinance of the :jurisdiction:' No permit presuming to give; authority to violate or cancel the provisions of thi code shall': be valid. 6 . Manufacturers installation 'instructi ons required on site for the building inspectors ':review. Project Name/Tenant: 1 ,�.� 1t 1, PI A &lb Description of work to be done: E c t, c 'gyp E 4 1.......p ubi }i< i y oo F 0 L .pp, t,2r �cw .l e .r�x, Q /Llla �uc •,4t5 P 4a Value of Construction: a�° Site Address: �__ ], City State /Zip: 11 , s.4.1� til 6,1�1 �1 Tax Parcel Number: ,Ziz --- g1 1c -4) Property Owner: . PM _ 01. Street Address : • \ A.. w , Contact Person: :c ) W -A— P one: t)'4,3.(4-' -- - Z-Ple2C, � i a ' , GR .. • . M -- n City State /Zip: . - ._ / IC r .. ax #: Phone: Street Address: 2-01 4 l' .1i'. ,7 - Avz E &il .% la - C9 Wa City State /Zip: ` i 2;.%4 0 Fa #: ( 'r1 Contractor: it = Ar i�- 4 i rfr. 4- L�r 'i� —, + 11-441/41--- v ��>= \�c )p., � ��City � (� State /Zip: ( Zr� x Phone: 2-bL� r I c --4 6.514.0 J i #: � 5'75 — � 31v� `1hon�e.L.'� '2>,Ir, 3 — 6Y-R4- Street s: i ! ( �Z� Architect: �' �r rA1.._, :jam n t•e &t,e . Street Address: City State /Zip: ax #: Engineer: - one. Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BYAPPLICANT)', Description of work to be done: E c t, c 'gyp E 4 1.......p ubi }i< i y oo F 0 L .pp, t,2r �cw .l e .r�x, Q /Llla �uc •,4t5 P 4a Will there be storage of flammable /combustible hazardous material in the building? El yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes ❑ Demolition El Fence El Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting El Bulkhead /Docks ❑ Commercial Reroof Mechanical El Manufactured Housing- Replacement only ❑ Temporary Pedestrian Protection /Exit Systems MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: 1 City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # El Miscellaneous WATER METER DEPOSIT /REFUND BILLING: Name: Address: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date Ippljcatlon� d:� 1 . 1 rnfl ni AI .1 in CITY ,OF TyKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Date apgticPtloZ FO: STAFF USE ONLY Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST. FOR MISCELLANEOUS PUBLIC WORKS PERMITS El Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public El Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load/Hauling City /State /Zip: Phone: Appl/catloq . ken by: (Initials) BUILDING OWN 'R OR SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 _ 1 ;ENT: I Date: /0 /".. 11 Print name: 1 ✓f._`� a ) _ 7. _ f 1r` 1��L /L` h- ono: P I7` C 3 io C, City /Stale /Zip N � Fa x # r� : 8 ‘1..... vS Address: cc.)/4_, /'C) /'? 41/C C - ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist' No:'; M -9 in Antennas /Satellite Dishes , Submit checklist • Not M -1 ❑ Awnings /Canopies - • No signage Comrnercial,Tenant Improvement .: Permit ❑ Bulkhead/Dock Submit checklist • ' No M -10 ❑ Commercial Reroof: , Submit checklist :. No: M -6 ' ❑ Demolition. Submit checklist,. No M -3, M -3a -'. ❑ Fences - Over 6 feet in Height Submit checklist No:. M -9 ❑ Land Altering/Grading /Preloads Submit checklist . No: M -2 ❑ Loading;Docks Commercial Tenant Improvement ;Permit., Subibit checklist No;.H =17 j Mechanical (Residential & Commercial) Submit checklist .` No.. M -8, Residential only - H -6, H -16. in Miscellaneous Works Permits : Submit checklist No : H -9 ❑ Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No M -5 ❑ Moving;Oversized Load /Hauling Submit checklist No: M -5' ❑ Parking Lots Submit checklist No: M -4 ❑ Residential•Reroof - Exempt With following exception: If roof structure to be.repaired.or replaced Residential Building Permit Submit. checklist :, No:. M -6 ❑ Retaining Walls - Over 4 feet in height Submit checklist No M -1 ❑ Temporary: Facilities Submit checklist. No: M -7 ❑ Temporary Pedestrian Protection/Exit Systems Submit checklist No M -4 ❑ Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS P 'MIT APPLICATIONS MUST BE SUB ' TED WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent. If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application, and obtain the permit will be required as part of this submittal. i HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 - 7 - 7 -- e7.,"\777sx:m.5777,3\-1,77.74.7rm" , rt , r7vrrl-rrzygrnlivrwwie,Fir,7r,v 7 ,7,..m. 77 '• C) **A** fly or vu Kw ILA cy 4VANN1! *****Ah.or.h4*.k.A.A.A.A*A4*A***-4-*A.A..k.,,A*A*A.A4A*A**A*4.Ak4 lEhNSMIT Number: P9000179 Amount: . 46.0 11/01/9? 10:.43 Pavmant Method: CHI:T1( Notation: 3E(4-AIRE M Init: FLU Permit No: M99-020 Typet B-MECH MECHANICAL PERMIT Parcel Not 262304-9079 3ite? Addreecit 1 SUUTACENIER PY Total irofiL • This; Pzovment 46.50 .TotPl ALL Pmtsi: • .4.50 Oalancet '.00 * Ac(.'ount Code Deecriotion 000/345.El30 PLAN CHECV - NUNRE9 000/322.100 mrcHolacm. NONRES 344 5 11/029710 Amount 9.30 ..3 TOTAL 46.50 Pr JM Ay IL T •e-6,f /Tnspectio): ."is Date called: /07 ----... Special instructions: Date wanted: / 1 r 11 / a.m. 4 P.m.,- Requester: /� Phone: ` - 5 2! 0 INSP TION NO. COMMENTS: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. InspectoC: 1)," Date: // $47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pro ect 1 goleia 1 / 4 h T e of Ins a V. -7 ,t-o Address: � / � ✓[! l kS.C, Date called: Special instructions: � A t**/ Date wanted;,� ice' 4 7 , p.m. Requester:4i Phone: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 (206)431 -3670 Approved per applicabl odes. ❑ Corrections required prior to approval. COMMENTS: L l(:/70kI.5 r ®E2 < fo 7 / 10/44 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: P7, &41,16i!'.Gl.� T Y p .if 1 p t i0 c a, �! V �� uuc�1 f -�l Address ve /4 1 Date called: 1 ecial instruc 1 ns: / 73 5 Date wanted: f� //� �j m,� ! / / /9m,/ Requester: Phone : —5 7s ,_ Q36 a INSPECTION NO, INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Date: PERMIT NO, (206)431 -3670 Approved per applicable codes. i g Corrections required prior to approval. COMMENTS: '1 � P t o 7 `A'? e -11— `. 1 1 7 - ' (` _�� �. P 4 4 1 0 -t€-L c,fi f f at` Inspector: J!` Date: E $47.01 REINSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: 3Z ALE O?Y Oct-20-99 2:34PM; Page 1/2 Sent SENT mam / construct ion; / 253 X 854 X 11 785; JOHN A. IQJMA, P,B, Job No. _Date /.._� % Lior ) P.O. Sow 86$ Imqueh, WA 98027.0868 Tide )/l 4 (.) . Co 1..2 ST A J L q 1 •.I (206) 392.6043 1144 253 854 1785) M 1 SubJer‹ G1G_ UM 17 DES Tor is , ; a "= ;...0,A� "" 3 b aS !S r 6 (, o b a* Po--f ctize (• 1 - k f�, = 4 1107 , - ,s'lii84- I- 4 i ? d �- Gi 1..0 1. a-M A L. y -rlo H P'.Je 11, CdV D si c.&i ep IA3 A 2Z . � V Ala u..) 1. t' Gu t'tt b 4-L r Al.)t 7400 Ass v s -ry rte.. w e1 414 r p PO vl_.'t -p `f' ;' i 7. t " C 4. • iv 7^ AN,. V/ - 114 +7 r ?87.0 # rtJ —Qeck)x 14r /138,¢" Ip(o' 'f0 , ,.t r R -,t.. 4-0 oc- UtJ 1 r 54)1= pc 1:. " 4 t 11.) Q-e'SP .TIV� ' — USt ($4# Po ; avCAJV--s ; 4P AEG C, ct S P+ESI4 . SOUP Nc:) PERMIT CEN) 60'' ?o►2. 3 - 2 x 4 S- „ .. +ecrt.x / l047 44 A. ADD Go:J .rto .► Gi1ADE 2.7 4- / 5b lD o rL. tow C A1 (; V -- ,t ^.J 'O fV e Sup P g..r use zr 411. p t�.. ,* /415 y` Armons/V /74%8) OI`I Y op T ()I( LA O CT 2 5 1999 Mgr' - n)13(0 , Sent By: mam construction; •' SENT BY: A . t10 -20-99 2 :52PM : JOHN A. K41MA, P.E. Job Ne.4 7 Date I (,�. oL ) ,.o. K.* O Issaquah. WA 11027.0860 Title_ X�'i / • / I d d a'S C�:7 � We) 3924043 subject RIJOF 1,9 9 h p atir A /c.. Avg tr ec.K; 3%4:.4 I=, nu /t.i ki. 51/44517 rgaMEWANOWWW, • Sf' �<.. �a::',' i; i' �,: iJt` �t ,'�:tt.;i:,.;.t.i ✓+�aiikN; »:;,a 7wc:: u7:. i9"^°. ri'. I! �G .'F:iYrFA,",'t'S�a74?t }k:t'.'� kYFtr.�1��415�Fk'��.'tr �iY:'.>.: tFi:?~ r? G! k�: iiT!' 1. 4' RMFYSh` 1i.' C1TM1; C�iA+ �'I S: L' t (at?�Y�tCWI�:A.'L'.:r�!TF,(yY.' 511 (4. 4 253 854 1785; Oct -20.99 2:35PM; Page 2/2 '144 253 854 1785 :14 2 f1-' 1t44i # 4 '. (L34/m- X1311. s X14 - i b► qt4, 3 / 5 Z 4,,) 5?z.� 1 S 4 ' 7.1) 416 4) ' o;w, PIVEVED CITY OF TUKWIt.A OCT 2 5 1593 ._.. PERMIT CEN 4xio 3'I fc.,0.1... E.14 CMC Locawk+42 Z._ jA.:10itsts rwz- attotwieTs''' - hitt.) 32. 114 )(' V` A-1 4. tn Zicie 0.0.1k-ot -D• )r-w e .ot , ...= I th.‘t Pk IZton '11 "if t 4) IRAN E Packaged Heat Pumps . _ C -D -4 October 1996 I F VoyagerTM 3 through 20 Tons — 60HZ Mq CiDa, Table 9 -1 General Data Sound Rating (GELS)' Refrigerant Charge (Lbs of R -22) 7.1 7.1 7.6 *lndrealos both downllow and honzontal units. 9 C General CJ, 4 Ton Data r 3 Ton Downflow Units 4 Ton Downflow and Horizontal Units WCD036C1 WCD036C3,C4 WC*048C1 WC*048C3,C4,CW Cooling Performance' Gross Cooling Capacity 39,400 39,400 49,900 49,900 SEER' 10.10 10.50 10.50 10.50 Nominal CFM /ARI Rated CFM 1,200 / 1,200 1,200 / 1,200 1,600 / 1,600 1,600 / 1,600 ARI Net Cooling Capacity 38,000 38,000 48,000 48,000 Integrated Part Load Value - - - - System Power (KW) 4.24 4.00 5.17 5.05 Heating Performance' High Temp. 8tuh Rating 35,000 36,000 46,500 47,000 System Power KW 3.42 3.52 4.54 4.59 Low Temp. Btuh Rating 19,000 19,300 25,300 24,900 System Power KW 2.78 2.82 3.71 3.65 HSPF (BIu/Watts•hr) 6.80 6.80 7.00 7.00 Compressor No./Type 1 /Climatufl® 1 /Climatuff 1 /Climatuff 1 /Climatuff 8.2 8.2 8.6 8.6 Outdoor Coll - Type Hi- Performance HI- Performance Hi- Performance HI- Performance Tube Size (In.) OD .375 .375 .375 .375 Faco Area (sq ft) 6.29 6.29 8.79 8.79 Rows /FPI 2/16 2/16 2/16 2/18 Refrigerant Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve Indoor Coil - Type Hi- Performance Hi- Performance HI- Performance HI- Performance Tube Size (In.) .375 .375 .375 .375 Face Area (sq It) 6.33 8.33 4.83 4.83 Rows/FPI 2/15 2/15 3/15 3/15 Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice Drain Connection No. /Size (in.) 1P /, PVC 1PA PVC 1/' 4 PVC 1PA PVC Outdoor Fan - Typo Propeller Propeller Propeller Propeller No. Used /Diameter (In.) 1/24 1/24 1/24 1/24 Drive Type /No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM 3,270 3,270 4,100 4,100 No, Motors /HP 1/.25 1/.25 1/.33 1/.33 Motor RPM 850 850 1,075 1,075 Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used 1 1 1 1 Diameter x Width (in.) 9 x 9 9 x 9 12 x 9 12 x 9 Drive Type /No. Speeds Direct/2 Direct/2 DlrecV2 Direct/2 No. Motors 1 1 1 1 Motor HP (Standard /Oversized) .33/.40 .33/.40 .50/.75 .50/.75 Motor RPM (Standard /Oversized) 1,075/1,400 1,075/1,400 850/1,040 850/1,040 Motor Frame Size (Standard /Oversized) 48/48 48/48 48/48 48/48 Filters -- Type Throwaway Throwaway Throwaway Throwaway Furnished? - Downflow Yes Yes Yes Yes - Horizontal Yes Yes Yes Yes (No.) Size Recommended (in.) (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 7.6 NOTES I. Cooling Performance and Heating Performance is rated at 05 F ambient, 60 F entering dry bulb, 67 F entering wet bulb . Gross capacity does not Include the effect of Ian motor heat. ARI capacity is nut and includes the effect of Ian motor heat. Units are suitable for operation to 120% of nominal clm. Rated In accordance with ARI Standard 210/240 „ or I 340, 2. SEER is rated at ARI conditions and in accordance with DOE last procedures. �0E1•Ed ' w 3. Sound Rating is rated in accordance with ARI Standard 270 or 370. v' „ Z .1 L I'• 4. Rolrigurant charge Is an approximate value. For a more precise value, see unit nameplate and service Instructions. 1' OF 1 �+r��� 5 WCH048 requires (2) 16 x 25 x I filters. o ci 2 5 1995 PERMIT CENTER All dimensions are In Inches, EVAPORATOR SECT ACCESS PANEL 5I. 2" ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) CONTROL B COMPRESSOR ACCESS PANEL ( .. Dimensional C 3 -5 Ton Data CURB DIMENSIONS CLEARANCE 36 77% TOP PANEL 64 ��I• 7 / e NA HOLE (UNIT CONTROL WIRES) 4 6 9 / 1 • n .. r. r , ,._r.. ... a , woa_��.n. „..;..,nx.r n•r , m<..r. � CONDENSER FAN 1 33 I CONDENSER COIL 2 OIA HOLE ( UNIT POWER WIRES) NOTE: RECOMMENDED CLEARANCE 46 FRONT, 36 SIDES,'16 REAR OVERALL DIMENSIONS CRATED 771/ 37.5H X 50.13WX 95.50 ALL DIMENSIONS IN INCHES 43 % h CLEARANCE 18 HORIZONTAL �. 36 DOWNFLOW . 446 TYPICAL ROOF OPENING 39 > 46 ' 44 � ��'” II/ CLEARANCE 'J• 4 RECEIVED CITY OFTUKWILA : pC 2 5 1999 . PERMIT CENTER 4 Table 87 -1 Accessory Net Weights (Lbs) Tons • rr 4 WCDO48C WCH048C 1 Unit Model No. 20 WCDO6OC CH060C C *075C C *090C 0 CD1208 2 CD150,1 rB 02408 12 Tons W 120 5 WC WCH2406 Unit Model No. WCD048C WCH048C WCH '/. WC *0 .0 '14 WC* OB Table 87 -1 (Continued) 0 WCD1 'B 214,15 WCD1 ,1808 WCD2 rB 1r WCH1 B 12' 15 WCH1 '• :OB 20 WCH240B *Indicates both downllow and horizontal units. All Zone Sensors Weights C 3 -20 Ton Economizer' Outside Air Damper Not Ship Manual 40 40 40 40 55 60 5.18 KW 240/480V 28 1 2:'1 2: 21 21 32 32 32 57 High Power Roof Oversized Static Motorized Exhaust' Curb' Motor Drive Adder N/A N/A N/A N/A 210 32 75 NOTES; 1. Net weight should be added to unit weight when ordering lactory installed economizer or oversize motor. 2. For 600V healers net weights are same as 480V heaters. 3. To estimate shipping weight add 5 lbs to net weight. 4, Downliow only. 23.36 KW 240/480V' 20 20 20 26 26 31/ 31 7 7 /27 1/27 33/27 N/A N/A A Electric Heaters 80 40 70 40 70 32 65' 8 5 40 160 32 3 75 .5 5 65 • 32 95 •r5 5 80 265 32 7' 95 235 I. 35 110 2 35 — — 150 3 60 — — 5 54 KW 240/480V" 240/480V" /32 /32 40/32 38/32 38/32 40/32 kt 5 5 " 5 5 I 5 5 PERMIT CENTER 72 KW 43/34 RECEIVED CITY OP TUKWILA • °Waa tee both downflow end horiwrMal units. Weights Tabl.08.1 Maximum Unit Weights, Corner Weights (Lbs) And Center 01 Gravity Dimensions (in.) .,; ",�.s��'�'�c�t�;i` %a's,�';ir' '•. + "i�aiZ.. "l�'k.i�,?; �:;" t ry �? �tF`, �,` r�; �:i?`1�,�.s;- "�i<f�:xlff�'?"�Oi Maximum Weights (Lbs)' Corner Weights (Lbs)' Center of Gravity (In.) Unit Model No Shipping Net A © C D Length Width 1750 1410 2385 1920 20 WC*240 NOTE: 1. Corner weights rare given for Information only. 10.20 Ion models must be supported continuously bye curb or equivalent Irame support. - T £ A CENTER OF GRAVIT WIDTH D CENTER OF GRAVITY _ r e 249 46 29 802 492 372 454 55 37 r____ CENTER OF GRAVITY LENGTH •Y 3 -20 Ton C arm OR r I.A OCT 2 5 1999 PERMIT CENTER • Honeywell T7200D,E, T7300D,E,F and Q7300 Series 2000 Programmable Commercial Thermostats and Subbases '. 4 , +: df. AM a APPLICATION :Ttie.T7200, T7300 Thermostats and 07300 Subbases control 24 Vac commercial single zone heating, ventilating and air conditioning (HVAC) equipment. FEATURES AIlModels: • 7-day programming. • ITwo Occupied and two Unoccupied periods per day. • individual heat and cool setpoints available for :',. Occupied and Unoccupied periods. •, .Proportional plus Integral (P +I) control eliminates temperature fluctuations. • Intelligent Recovery® control automatically optimizes . equipment start times based on building load. • intelligent Fan feature energizes fan continuously in • 'the Occupied periods. Fan can also be configured for conventional heat or electric heat fan operation. U.S. Registered Trademark • Automatic or manual changeover models available. • Universal VersaguardTM Thermostat guards available. • Convenient overrides allow temporary setpoint changes. • Keypad lockout available. T7200D,E Thermostats • Use on single -stage conventional (T7200D) or heat pump (T7200E) applications. T7300D,E Thermostats: • Use on multistage conventional (17300D) or heat pump (T7300E) applications. • Models available with remote sensor capability. 17300F Thermostats: • Use on single -stage or multistage system in conventional or heat pump applications. • Auxiliary contacts on 07300 can be used to interface with C7400/W7459 Economizer System for total integration of rooftop control. • Remote temperature sensors available for use with all models. • Different levels of keypad lockout available. 07300 Subbase: • Use with T7300D,E,F Thermostats. • Auxiliary contacts can be used.to Interface with C7400/W7459 Economizer Syste J8 ij Integration of rooftop contro bi'f'r Op mKWILA OCT 2 5 1999 Application 1 Features , 1 Specifications 2 Ordering Information 2 Installation 5 Wiring Subbase or Wallplate 7 Settings 9 Installer Setup 10 Installer System Test 14 Programming 16 Operation 20 General Operation Information 22 Troubleshooting Guide 23 Cross Reference 25 Wiring Diagrams 34 C f Y PERMIT CENTER Contents h i i i ACTIVITY NUMBER: M99 -0206 PROJECT NAME: WASHBURN PIANO XX Original Plan Submittal DATE: 10 -25 -99 Response to Incomplete Letter # Response to Correction Letter # _ Revision # _ After Permit Is Issued DEPARTMENTS: Buil ic'�ng Division A)G 1b L(p -41 1 u lic Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 4.p Comments: TUES /THURS ROUTING: Please Route PEUIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions NNW U'RROUTE.DOC 5/99 /l/ Fire Prevention fiel ! Stru ura CORRECTION DETERMINATION: Approved n Approved with Conditions n REVIEWER'S INITIALS: Planning Division Permit Coordinator ig DUE DATE: 10-26 -99 Not Applicable n n No further Review Required DATE: DUE DATE 11 -23 -99 Not Approved (attach comments) n DATE: DUE DATE Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Residing In REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CCO1 SEAAISM081B9 04/18/2000 EFFECTIVE DATE 01/29/1992 SEA • AIRE SHEET METAL INC 2014 136TH ,AVE .E- SUMNER WA .98390 SS �9 ^ � Q; t DEPARTMENT OF LABOR AND INDUSTRIES in: a 0 0 0 1 . ° '• Z ° 2 ' U � I HEREBY CERTIFY THAT THIS IS A TRUE AND EXACT COPY OF THE ORIGINAL DOCUMENT faJ&A.AS S Notary Public In and For the State of ko lo oz Commission Expires washburn piano store drawing index vicinity map legal description stock & associate ' % , , UNLIMITED 2 000 S.F E • 1 0 E _ OF H CLOKS 2 000 S.F_ WALLPAPER TO GO 3, 000 S.F. BERGMANS_ LUGGAGE 4,000 S.F. INTERNATIONAL) 9,236 S.F. COMPUTER RENAISSANCE 1.446 S.F. ////////// IIIIIIIIII11I11111111 ci( C 0 0 0 12E.�S16MiRANT ■ ■ f +:4 4.. + 4 0 +_+ +i ■ SITE PLAN LOCATION OF SITE: WASHBURN PIANO COMPANY J 0 n 0 n. 0 U 0 0 0 V V V U, V L ON I STOCK & ASSOCIATES ARCHITECTURE AND INTERIORS 109 Bell Sceet Seattle, Washington. 98121 Telephone: 206 443.0494 Facsimile: 206 443.0495 http: / /www.stockandassodates.com ssa l REGISTERED \ AAR. ,,,,,, STEVEN A. ERICKSON STATE OF 4 /ASHINGTON IMO PERMIT SET 30 SEPT 99 A1.1 SCALE: DRAWN: RGM CHECKED: PROJECT NO: 99032.02 SIT E PLAN eI nr ,,1.A PERMIT CENTER NOTES L ALL EXISTING LIGHTS IN SCOPE OF WORK ARE TO BE RELOCATED AND REUSED 2. MODIFICATIONS TO EXISTING SPRINKLER SYSTEM TO BE UNDER SEPERATE PERMIT LIGHTING CALCULATION EXEMPT FROM LIGHTING CALC NO CHANGES ARE BEING MADE TO THE CURRENT LIGHTING CONDITIONS LEGEND 1 1 1 1 1 i l 1 I� � EXISTING RELOCATED 2 X 4 FLUORESCENT LIGHT V FIXTURES: 4 LAMPS, 1281LI EA INDICATES SCOPE OF WORK NOTES: CONTRACTOR TO VERIFY EXISTING EMERGENCY LIGHTING CONTRACTOR TO VERIFY EXISTING SWITCHING CONTRACTOR TO COORDINATE ANY SPRINKLER MODIFICATIONS A STORAGE 108 HANDICAP RESTROOM HANDICAP RESTROOM 106 VESTIBULE REFLECTED CEILING PLAN SCALE: VS" = I' -0" STUDIO 103 HARD LID CEILING W/ ACOUSTICAL BATT MSULATICTI ABOVE STUDIO flh i 2cuF dYP(i �O�ESo 1; un�� 'nuJ t 51'1c[�> i Off'• • S -roe- leo f31' �E e U qua 15D dra A11 $eput�. -t 4o &4< lloI £ 4'B -S W!LD5IR UNLIMITED HALLMARK NEW CEILING GRID AND TILES TO MATCH EXISTING e ADJACENT SHOWROOM I STOCK & ASS OCIATES AR CHI TE CTURE AND BVT ERICRS 109 Bell Street Seattle, Washin¢ ton 98121 Telephone: 206 443.0494 Facimile: 206 443.0495 http: / /www.stockandassociates.com 5 PERMIT SET 30 SEPT 99 y624 ARCHITECT' / 1 S A� ERIC SON STATE OF WASHINGTON 9 SCALE: 1/8" = 1' -0" DRAWN: RCM CHECKED: PROJECT NO: 99032.02 Q of 0 co . 00 LIJ z- W T vJ REFLECTED CEILING�� PLAN: PERMIT-CENTER A2.2