Loading...
HomeMy WebLinkAboutPermit M99-0228 - VAL VUE SEWERM99 -0228 14816 Military Rd. So., Ste. 01 Val -vue Sewer City of Tukwila (-% (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M99 -0228 Type: B -MECH Category: NRES. Address: 14816 MILITARY RD S St: 01 Location: Parcel #: 004100 -0083 Contractor License No: TENANT VAL -VUE SEWER Phone: 14816 MILITARY RD S, TUKWILA, WA 98188 OWNER VAL VUE SEWER DIST Phone: (206)000 -0000 PO BOX 68063, SEATTLE WA 98168 CONTACT DANA DICK Phone: 206 - 242 -3236 14816 MILITARY RD S, TUKWILA, WA 98188 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALLATION OF A GAS -FIRED RADIANT, LOW - INTENSITY INFRARED HEATER. UMC Edition: 1997 ******************************************** * * * * * * * * ** * * * * * * * * * * * * * * * * * * * * ** 1 HO Permit Center thorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the • ovisions of any other state or . local laws regulating construction or the perform nce of work. I am authorized to sign for and obtain this bui ding permi Signature: 1 ! Date: ) /A' q Print Name:__ 4?±U4 _ __,�� G �- Title: s'J T. / "G -�—• MECHANICAL PERMIT Status: ISSUED Issued: 11/10/1999 Expires: 05/08/2000 Valuation: 1,000.00 Total Permit Fee: 61.19 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if•the work is suspended or abandoned for a period of 180 days from the last 'inspection. Address: 14836 MILITARY RD S St: 01 Permit No: M99-.0228 Suite: Tenant: VAL-VUE SEWER Status: ISSUED Type: B-MECH Applied: 11/10/1999 Parcel It: 004100-0083 , Issued: 11/10/1999 *************************************************************************** Permit Conditions: 1. No changes will be made to the plans unless approved by the Engineer and •the Tukwila Building-DIvlsi 2. All permits, inspection:reeerdnd-40.0ve4 plans shall be available at the job:Siteprior to the sta61 con- struction. ThescedocuMents=ay.e to be maintained and avail- able until Final:inspection apfirovaTils granted. 3:. All construction'Lobe done bonformance,w,ith apprOved • plans and reqU'irements 'of the Uniform Building Code(3.997 Edition) as.amended, Uniform Mechanical (1997 Edition), and Washiligton State Energy Code (1997 . Edif,ion), (±, 4. Validity,OF PerMi,t. The issuance 'of ,a permWor approVal Of plans,,,s0cifications, and':f shall riot be Con- trued :to be/a permit For, or ,an approval of, any ,vioiationl, of anVt)f the proVisions of the building code or of any other the,jurisqiction. No permit presumin4 tO'% give authority to violate or cancel the provisions 0F this ' codd be valid. 5. Manufacturens installation 4bstructions'reouired on site , fore,b4ilding lnspectorsevieW. CITY OF TLJKWILA •• Project Name/Tenant: ) V V . (A/C. r• ail - Vie - 7 i ' Value of Mechanical Equipment: 41► 000 ha- Site Address : l'1,'/4 /rr /i e City State/Zip: ad s, �c'Q7 4 wr4 014 ( Ta Parcel Number: Property Owner: Date: h Jd I9 Print name: Phone: (206 ) ,rya,- 37,3A4 Street Address: Phone: ( R06 ) ,Ry2 323,6 City State /Zip: Fax it: (,'06, ) . t.) -i5--.2 Contractor: feif fi Phone: ( ) W4 ` 0 i 6 er . Street Address: JO )^z. C City State /Zip: Fax it: ( ) Conta�Person: /c_(C Phone: (m( ,,) ^w Street Address: .Q e City State /Zip: Fax if: ( ) BUILDING. ER. OR AUTHOR ED GENT: Signature: la ' Date: h Jd I9 Print name: 4114 I �/ Phone: ( R06 ) ,Ry2 323,6 Fax #: -3 ‘12. JS A/ Y, /6 / C111 fi City /State /Zip: W4 ` 0 i 6 er . Mechanical Permit Application Description of work to be don (please be specific): 'e //4�j0h o ce 11/2/99 inec/ nerndLdoc CITY OF T ► /KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Date a rlicat accep e 1OR STAI f USE ONLY Project Numb.. . Permit Number. f -F ;e1 /Cao�Q�f Date a xpires: '1( Low Current copy of Washington State Department of Labor and Industries Valid Contractor's License. 0 not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Application t k n by: (initials) ✓ Submittal Requirements Floor plan and system layout Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -7 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal RESIDENTIAL: Two complete sets of attachments required with application submittal Heat loss calculations or Form H -6. Equipment specifications. /1/2/99 Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. ndrepnitdoc NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. Submittal Requirements New Single Family Residence Change -out or replacement of existing mechanical equipment Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. ************************15*** **********************************), CITY OF TUKWILA, WA \ C I - TRANSMn TRANSMIT Number: R9800184 Amount: 61.19 11/10/99 13::Q Payment Method: CHECK Notation: VAL VUE SEWER DI Init: TLF Permit No: M99-0228 Type: B-MECH MECHANICAL PERMIT Parcel No: 004100-0083 Site Address: 14816 MILITARY RD S St: 01 Fl: Un: Total Fees: 61.10 This Payment 61.19 Total ALL Pmts: 6 1 .1P Balance: .00 *************************************************************A4* Account Code ; Description Amour),. 000/345.830 f PLAN CHECK - NONRES 12.21 000/322.100 MECHANICAL - NONRES 4B.W' 8727 4/12 970 TOTAL 61 ,19 Y.:ICS1 12.24 '1 48.95 CHECK 61.19 11/12/99 19 01144 0097 0727 arr OF TUKWILA VA, (i 20 Type e io .77. Alm i 6" b �) f �-� Date called: 1 2 " . ! M / Special Instructions: Date wanted: /2_13/ r Requester: (i,,, , c Phone: fix- ' 52.3 6, Insp I 1 INSPECTION RECORD Gam' Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. Receipt No: I Date: 1�1 fig PERMIT NO. (20431 -3670 Corrections required prior to approval. COMMENTS /1 e enei , pe,e , n / ;1 3 l E TX Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ;r Project: 1 , cl U 1 V e_ Type of Inspection: v , = Add Le afl� �d s Date called: � / < <�. Spial Instructions: Date wanted: f r a ` Requester: Phone: 20 co _ / z_ .5z INSPECTI I N NO, Approved per applicable codes. Retain a copy with permit INSPECTION RECOR 'CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 in y7 -OZZ PERMIT NO. (206)431 -3670 [Corrections required prior to approval. COMMENTS: /cx4 pr,t $47.00 REINSPECTION I4 REQUIRtD. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No: Date: Model Characteri CENTER TR Indoor, Gas - Fired, Low - Intensity Infrared Tubular System, 0 -2000 ft elevation TR -H Indoor, Gas - Fired, Low - Intensity Infrared Tubular System, 2001 -8000 ft elevation Paragraph No. REZNOR Thomas etts Page GENERAL 1 HEATER INSTALLATION 1A. Installation Codes 2 113, Warranty 2 2. Description /General 2 3. Specifications 3 4. Clearances to Combustibles 3 5. Location and Mounting Height 4 6. Uncrating /Packaging 4 7. Suspension Dimensions and Preparation 5 8. Prepare and Install Burner /Control Box and Combus- tion Chamber Tube 6 9. Install the Heat Exchanger Tube(s), Tail Pipe Tube, and Turbulator Strip 8 10. Install Reflectors (including Standard Reflectors, Optional Side Shield, and Optional Reflector Gap and End Covers) 11 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. Don't touch electrical switches. 3. Extinguish any open flame. 4. Immediately call your gas supplier. WARNING: Gas -fired appliances are not designed for use in hazardous atmospheres containing flammable vapors or combustible dust, in atmospheres containing chlorinated or halogenated hydrocarbons, or in applica- tions with airborne silicone substances. See Hazard Levels, Page 2. GENERAL Installation should be done by a qualified agency in accordance with the instructions in this manual and in compliance with all codes and requirements of authorities having jurisdiction. The instructions in this manual apply to the heater models shown on the right. Table of Contents Q , Gas -Fired Tubular, 053 Radiant, Low - Intensity Infrared Heater INSTALLATION FORM RGM 456 -A Obsolctcs Form 456 -2 APPLIES TO: INFRA- REZT"' Heater Models TR/TR -H Paragraph No. II. Venting 12 12. Combustion Air 17 13. Gas Piping and Pressures 18 14. Electrical Supply and Connections 19 15. Check Installation and Start -Up 21 OPTIONAL EQUIPMENT -- Field Installed 16.Optional Heat Exchanger Tubes ("U", "L ", 5 -ft) 22 17. Hanger Kit, Option CK11 22 18. Turnbuckle Kit, Options CK12 -18 22 19. Combustion Air Inlet Kit, Option DE2 23 20. Dual Vent Kit, Option CC5 23 21. Optional Side Shield, Options CD13 -20 23 22. Optional Reflector Gap and End and Gap Covers 23 23. Multiple Heater Control, Options CL31 and 32 23 24. Optional Unit - Mounted Thermostat Bracket Kit, Option CM3 23 Index 24 FOR YOUR SAFETY The use and storage of gasoline or other flam- mable vapors and liquids in open containers in the vicinity of this appliance is hazardous. WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause property damage, injury or death. Read the installation, operation, and maintenance instructions thoroughly before inst�llinor ser- c�I � vicing this equipment. CITY OF TUKWILA Vilcici alp l)22. NOV 10 1999 Page Mfg No. 121027 Page 1 BTUH Input Minimum Length Maximum Length 50,000 >" 20 feet 30 feet 75,000 20 feet 40 feet 100,000 30 feet 50 feet 125,000 40 feet 50 feet 150,000 50 feet. 60 feet •: 175,000 50 feet 70 feet 200,000 :; 50 feet 70 feet Voltage /Phase Standard 115 /1; Optional 208/1, 230/1,460/1 Frequency 60 Hertz Maximum Amps 3.0 Flame Safety Electronic Pilot Burner Ignition Spark Main Burner Ignition Pilot Btuh Input Gas Type Supply Pressure Minimum Maximum 50,000- 150,000 Natural 4.5" w.c. 14" w.c. 175,000 - 200,000 Natural 6" w.c. 14" w.c. 50,000- 150.000 Propane 11" w.c. 14" w.c. `on tr ins, xtd,r,r Venting may be either vertical or horizontal. A vent cap is supplied and must be used with heaters with a C.G.A. rating plate. Heaters with an A.G.A. rating plate must be installed using a vent cap supplied as Op- tion BT2 or CC1 or a fully - comparable. Iield- supplied vent terminal cap such as a Type L Breidert Air- x- hauster®. (Type 1. Air -x- haunter® is a trademark of The G. C. Breidert Company.) Dual venting of two units is permissible when using an Optional I)uul Vent Kit (Option CC5). These heaters are approved for operation without outdoor vent- ing, Combustion air can either come from the heated space or he piped from outside. Outside combustion air should he supplied (I ) lithe build- ing atmosphere has negative pressure: (2) lithe building atmosphere is dirty or dusty: (3) if the building atmosphere contains substances that will cause toxic gas when combined with flame or flue products: or (4) if the heater is being installed in a tightly closed room that does not provide required air for combustion. Installation ofan Optional Com- bustion Air Inlet Kit is required to provide outside combustion air. 3. Specifications BTUH/Length /Configurations Depending on the length and size of the heater, the heat exchanger sections may be installed in various configurations. Optional "L"- shaped. 5 -foot, and "U "- shaped heat exchanger tubes are available to adapt the heaters to these configurations (Option UC2 for "L "; Option (J133 for "U ": Option UA I I'or 5 -foot heat exchanger tube). Refer to the Suspension Dirnensions and Configuration Drawings Booklet to de- termine the permissible configurations for each size and length ufheater and guidelines for using the 5 -It heat exchanger tube. Gas Type and Supply Gas Pressure Sizes M) -150 heaters are available for use with either natural or pro- pane gas. Sizes 175 -200 are available for use with natural gas only. The supply pressure listed is the gas pressure required at the gas valve inlet. Measure gas pressure with a manometer. Electrical Characteristics 4. Clearances to Combustibles Required clearances depend on the size of the heater (BTUH input), the position of the reflector. and the addition of an optional side shield on the rear side of the heater. Refer to illustrations in Figure I to define clearances. Clearances to Combustibles (inches) BTUH Input (000) 50/75/ 100 125/150 175/200 BTUH Input (000) 50/75/ 100 125/150 0 o 0. 0 - Horizontal Clearances Burner End Heat Exchanger Bend (U or L) Exhaust End 66: 12 ;' 4 : 36 24 :tz 30: 48 24 78 12 30 48 24 6 84 With Reflector Positioned 6 0 -30 31 -45 0.30 with Side Shield Front Rear Front a 30.;30 36 12 42 42 66 32 42 12 1 54 :54• 36 • lithe heater is not vented to the outside of the building, the top clearance to combustibles is 18 ". .• Refer to Paragraph 10 for side shield installation. 54 12 Figure 1 - Clearance Orientation 00 I1• Y 1101ic01 NLd MI/UNION n wiN 1N 1uN HORIZONTAL REFLECTOR .0„0N 011NK , 00111.11 \ \ \ \ \ \ \\ HORIZONTAL CLEARANCES / / / /( / /// 10. W N /LLR? NUN /N 1• NM V — 111ntc1N \\\\\\\\ REFLECTOR REFLECTOR ANGLED (1' to 45') J IVED CITY OF TUKWILA 11.1 NCO NOV 1 0 1999 \ PERMIT CENTER Page 3 TABLE OF CONTENTS Page Legend for Configuration 4;Arawings 1 ' ?fib : Ber/Control Box Dimon- z (All Sizes) 2 ,� h ' • • , , • Bon Selections .-. ilio and tength) ! , ' Model Size BTUH Configuration I LENGTH (1 straight tube =10) 20 30 40 50 60 70 50 50,000 Straight 3 8 — — — — With 'U' Tube 3-4 8-9 — — — — With 1.' Tube 3-4 5-6, 8-9 — — — — With 2'L' Tubes — 5-7 — — — — 75 75,000 Straight 3 8 14 — — — With 'U' Tube 3-4 8.9 18-19 — — — With 'L'Tube 3-4 5-6, 8-9 10, 14-15 — — — With 2'L' Tubes — 5-7 11-13, 16-17 — — — • .. pages —► i:' , 100 100,000 Straight — 8 14 20 — — .. pages --.- �. � 1• ti; ; _' • 54t Hat 4 ik ' n ''' • Tubes .... 62 " 83 Fiiiierences 64 y 1 • ? $' i i• .:1 ',1- '.` r' '•''`;t =r:. ,, • lls Minors required may hem Illustrated. vary r � Si erra of the installation lion sae. Follow carefully w carefully the 111tbt1ator Regikements on Page 63 '" With 'U' Tube — 8-9 18-19 28-29 — _ With 'L' Tube — 8 14-15 20.22 — — With 2'L• Tubes — — 16-17 23.27 — — 125 +185,000 Straight — — 14 20 — — With '11' Tubs — — 28.29 With 'L' Tube — — _IA 14 20-22 — — With 2 'L' Tubes — — 16-17 23-27 — — 150 150,000 Straight With 'U' Tube — — — 28-29 42.43 — With 'L' Tubs — — — 20-22 30-33 — With 2'L' Tubes — — — 23-27 34-41 175 175,000 Straight — — — 20 30 44 With 'U' Tube — — — 28-29 42-43 60-61 With 'L' Tut* — — — 20.22 30.33 44-47 With 2'L' Tubes — — — 23-27 34-41 16.59 200 200,000 Straight — — — 20 30 44 WIth'U' Tubs — — — 23-29 42-43 60-61 With 'L' Tube — — — 20-22 30 " 4 6c Mid OF Milt! TU A With 2'L' Tubes — — — 23-27 .iREZ • NOR MERCER, PA 16137 This booklet contains suspension dimension of all permissible instal- lation configurations for this model of tubular radiant heater. Use this booklet with Installation Form 456 for designing and Installing the tubular system layout. All configurations, including both left and right turns of the same layouts, are illustrated. Only those con- figuration layouts Illustrated for a particular size and length are approved for that heater. Do not Install any heater in a configuration that Installation Configurations and Hanger Suspension Point Dimensions TECHNICAL FORM RGM 607 -A OBSOLETES FORM 607-2 APPLIES TO: INFRA-REV" Heater Models TR /TR -H is not illustrated for that specific size and length. The only exception is the use of an optional 5-11 tieat.exchanger tube. To further customize a configuration, one or Iwo 5 -ft heat exchanger tubes may be used in place of the 10 -ft heat exchanger tube(s). 5.ft tubes are not illustrated in the configuration drawings. See page 62 for instructions on the use of 5 -ft heat exchanger tubes. Legend for Configuration Drawings (pages 3 - 61) • = Suspension < • Point I = Bumer /Control Box with Fiild•Attached 10 -ft Combustion Chamber Tube 2 10 -tt Straight Heat Exchanger Tube f t. ,,,,,,,,,, J = 10-11 Straight Heat Exchanger ,. Tube with Two Field - Installed Turbulator Sections NO1.0_1999 PERMIT CENTER = Optional "U" Heat Exchanger Tube Optional "L" Heat Exchanger Tube C , V ^ V - V = 10 -ft Tall Pipe with Three Field- installed Turbulator Sectloas CI e 40' 9 -1/2' 9'- • 9' —B' 9'— 7'/ 2' - 0" c t 1' -1' 9' -8' 32' 2 -1/2' 9' — B" 9' •7'/i' 11' -5' 10' -9' 22' 6 -1/2' t 1' - 9' —B'. 9'- 7'/ 2 - 0" *REPRESENTS THE OUTSIDE EDGE OF THE BURNER BOX. SEE BURNER BOX DRAWING FOR DETAILS OF BOX. — Page 2 10' -9' 21' -1' SIZES 75 -40 100 -40 125 -40 9' —8' AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON COUNTY OF KING AFFCONT.DOC 5/29/96 CITY OF TU°'VILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. , and will therefore not be performed by a registered contractor. 1.. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. , states as follows: I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. ss. AP`PLICANT Signed and sworn to before me this 1 0 day of WO u e el/ bcr , 19_g _. NOTAR PUBLIC in and for the State of Washington, residing at Name as commissioned: Pc/ v24 My commission expires: a - 3. -0 3 County, 1p �c H-4 3.27.090 Exemptions. This chapter sh,II not apply to: An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; Officers of a court when they are acting within the scope of their office; Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; . Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division FFCONT.DOC 5/29/96 of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within The scope of his license; 15. Any person who engages in tk' ;.. Vti'#'e5 herein regulated as an employee...Qt a ;�g�"sficred °contractor with wages as his sole ciar t ;,-c 16. Contractors on highway prdjec�te,vyhp lVebeen prequalified as required by chapterl3'of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work.