HomeMy WebLinkAboutPermit M99-0234 - GRAPHIC SYSTEMSM99 -0234
4493 So. 134 Pl.
Graphic Systems
City of Tukwila
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
Permit No: M99 -0234
Type: B -MECH
Category: NRES
Address: 4493 S 134 PL
Location:
Parcel #: 261320 -0084
Contractor License No: GRAPHS *0350F
UMC Edition: 1997
* ** * * **
Signature:
04.
Print Name: Tod Lcke.vIS
MECHANICAL PERMIT
(206) 431 -3670
Status: ISSUED
Issued: 12/08/1999
Expires: 06/05/2000
TENANT GRAPHIC SYSTEMS Phone:
4493 S 134 PL, TUKWILA, WA 98168
OWNER NORTHSTREAM PROPERTIES INC Phone: 425- 828 -6300
720 4TH AV, STE 102, KIRKLAND WA 98033
CONTACT TODD LIKENS Phone: 253- 589 -3144
2310 104 ST CT.S, A -3, TACOMA WA 98499
CONTRACTOR GRAPHIC SYSTEMS Phone: 253 - 589 -3144
850 NW 61ST ST, SEATTLE, WA 98107
*'k * * ** * * * **** *** *k * *'k * * * * * *'k * *** * *'k ' k * *'k* ***** A* . ** *'k * * ***** *•k* * * * * * **•k**
Permit Description:
INSTALLATION OF PRE - FABRICATED PAINT SPRAY BOOTH.
Valuation: 7,000.00
Total Permit Fee: 56.00
*� **********************• k************* * * * * * *'k * * * * * * ** * " k* * * * * * * * **
Permit Center Authorized Signature Date
I hereby certify that I have read and examined this permit and know the
same to be true and correct... All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this building permit.
Date: V-- (8±11
Title: 1092-4#
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
Address: 4493 S 134 PL
Suite:
Tenant: GRAPHIC SYSTEMS
Type: B-MECH
Parcel #: 261320 -0084
CITY OF TUKWILA
Permit No: M99• -0234
Status: ISSUED
Applied: 11/22/1999
Issued: 12/08/1999
*• k k*• k'X k**• k**** k•k*• k****** k***** k*************** *•k* * * *** *k* * * ** * *k*** **** *k*
Permit Conditions:
1. Electrical permits shall be obtained through the Washington
State Division of Labor and Industries..and all electrical
work will be inspected-by-that agency; (248 -6G30)
2. No changes wi 1 l be Made to the plans: unless approved by the
Engineer and the Tukwila. Bui 'Wing' Division.
3. All permits, :'inspection' records, and approved plan`s shall be
available at the job site prior to the start of any con-
,struction rhese document are to be maintained and avail -
,
able until final irrspection approval is granted
'All construct ton 'to be done in conformance' with;' approved
plans `and requirements of the Uniform Bui lding Code:, (.1997;;
Edition) as amended, Uniform Mechanical Code (1997 Edition),
and Washington State Energy Code '(1997 Edition)'.,
S. Validity of Permit.. The issuance of a permit or approval o
plans, specifications, and computations shat 1 not be con -:
str;ued to be a permi�t..for, ` or an approval of , any violation,
of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to
give authority to violate or cancel the provisions of this
code shall be valid.
G. Manufacturers installation Instructions required on site
for. :,the bui 1ding inspectors review,
Project Name/Tenant:
6CaPtlt(_. ,SNiSTf -•S 1+
Value of Mechanical Equipment:
O '7 boo, po
Site Address :
`x`{93 S. 134t^ ?t_A -ci.
City State/Zip:
TUiCwILF} W4 9811A
Tax Parcel Number:
l -32000 - 'c IO0
.Zeal -
Phone: ( `iz S) sib _ C3 00
Property Owner:
►.lo Trl -1 52 - g 6 -11--io 1? R o' Cc K “ INC_
Date: II I2Z l 5?
I
Street Address:
/20 4 ;ye. SurrE_ o
City State/Zip:
le!RI( LAN w• 980
Fax #: ( )
Contractor:
6ft/1fthc. 616TEAAS INC.
Phone: ( 2 r3 ) slag - 3,
Street Address:
23to - 104 r CT. 5, A -3
City State/Zi :
Tu .M . I 9 ••
Fax #: ( 3 ) r81 - 3 /Y.r
Contact Person:
To Do G, 11.Er.i S
`., A- 98y1 9
Phone: ( 23'3 ) S81 - 3 II Y
Street Address:
2.310 - lc»( 5T cv 5 . , A- -3
City State/Zip:
14-ct .A t wA- 88
Fax #: (1-3 ) s131 3 iY
BUILDING'OWNER OR AUTHORIZED AGENT:
Signature: ,::\oc.t,-0._
Date: II I2Z l 5?
Print name: •1—a °I a L. I�e✓ts
Phone: ( ZS3 ) 58q _ 3 i �iy
Fax #: (� ) $89 ,
/.7,4.
Address:
2310 - I0`4 ' � 5•f: Cf. S
f}- -3
City / Statep:
/Zi. c, ,
`., A- 98y1 9
CITY OF ('IKWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
MECHANIQAL;P.ERMIT;REVIEW AND APPROVAL'REQUESTED: (TO REFILLED OUT BY APPLICANT)
Description of work to be done (please be specific):
INS TA LL -676J Ot= ?RE - Pi4-3R: GfvrEt t�fr R Ay
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THiS PERMIT.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date ap lication accepted: Date application expires:
S M a a, -ocio
1 1/1/9 9
Application taken by: (initials)
✓
Submittal Requirements
Floor plan and system layout
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
.
Heat Loss Calculations or Washington State Energy Code Form #H -7
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
Specifications must be provided to show that replacement equipment complies with the efficiency ratings'
and other applicable requirements of the Washington State Nonresidential Energy Code.
Structural engineer's analysis is required for new and the replacement of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
11/2/99
miscpml,doc
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
RESIDENTIAL: Two complete sets of attachments required with application submittal
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H -6.
Equipment specifications.
Change -out or replacement of existing mechanical equipment
I Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
NOTE: Water heaters and vents are included in the Uniform Mechanical Code - please include any water
heaters or vents being installed or replaced.
Account Code
000/345.830
000/122,100,
.. ,, a.. y. ; {. ; ".'V•MN3'YPT; r;.7r; ^ w 4— t •I
1?e9cr•ipt;ian
PLAN CHECK -. t!rai RE1,3
MECHANICAL •- 1>!QrN321ia
:s >t �+: si. � sl �S Sk f• sk :k 'ts A •h. >'r sk •k fi. k st k 1; sk •k h• A >t• A * A W sk k h * ; 4 A i' s4 •k A .A. *>4 arc st sk >k .t A A •k sk /::s•.• k lk it * .t
CT•fY OF TUKWtI.A. WA f j Qc)- TRANSMIT ik•k *slsk**Aik*A *AA A *A*A *a khik44 <sk kA•As ><' sSS Fhsl-WA*11**skssslA•A;b*k*kAAAslk
TRANSMIT Number: I29800201 •l4:r oun 56.00,12t08/99: /O9 12.411
P vment: .Met;hrtdt C( 3H Motvtic;r'i: C•RAPHI:C''.t'r's31r ifi I:r',itt NCR
Per'•nS it; Not M99-6234 Type: l3•••MECFi MECHANtCAI. PERMIT
P rr.e1 3dut 261:120-0084
;iit€ Addr''Wsr~t 44933 .3 134 PL
TQt;ai t
fh i :s Payment '36.00 1 c:t:<<3 ALL Pmts
13:n1GinCe
A• *A* Ask• AslAA• k***• k: t. A As4: AA• Aitit 1 *:• k• AAid :Ai4 *A* *itsks4?r**i•sl *•A'AA•A *AhAAf,A•A•*.*atis , k
.,0177 Fir, r: gtlA;.4; -igr itlI rg .wr���y.�, =r,•r fit;
'36.00
`:rl.CO
„00
Amount
t.I,.20
44.80
Project;,—
/
Type of Ins cti n:
A dress
1
Date called:
Special instructions:
Date wanted
Requester: `I'L
...V
Phone:
206.-.. 0_3s
.
el INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 981
Sr. ;*7vll: cts ^rc >. ,;yxznA
PERMIT NO.
, J206 431 36 0
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
$47.00 REINSPECTIO !FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
P ject:
Type of Inspection
s �
� . �� /31/Opt
Date led:
/6775 /00
Special instructions:
Date wanted: y e9.69 / 00 a.m. p.m.
Requester: ,-g
Phone 333 o 4 0
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila WA 9818
INSPECTION NO.
e
2±1 INSPECTION RECORD
R a copy with permit
PERMIT NO,
(206)431 -3670
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
$47.00 REINSPECTIOI(V*EE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
P of ct:.
Type of Insp ction:
A dr
\
Date called:
Special
%.
instructions:
L T v.0 S t.
Date wanted: - y
a.m.
qatOaa,
P LP '7,4 '7 q
Lp
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with'permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION -
6300 Southcenter Blvd, #100, Tukwila, WA 98188
PERMIT NO.
(206)431 -3670
COMMENTS:
, f
4 O
• Z�,/ a< /` 1 ti / GEC% t.
y
Corrections required prior to approval.
$47.00 REINSPECTIO E REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
O
City of Tukwila
Fire Department
Project Name r ; / 1 i ,C 3.
Address `'/ (/ `% 3 ..S /3 y PL
TURWILA.FIRE:DEPARTMENT
FINAL APPROVAL FORM
Retain current inspection schedule
Needs shift inspection
< Approved without correction notice
Approved with correction notice issued
pr4 6031
pY :
Fire Alarm: A/
Hood & Duct: '.
Halon: ■/
Monitor: �.�.�. A ln. ,•.
Pre-Fire: 5 � I ��
Permits:
Authorized Signature
Permit No.
Date
FINALAPP.FRM T.F.D. Form F.P. 85
`'j - o), . `/
John 'W Rants, Mayor
Thomas P. Keefe, Fin? Chief.
Suite #
Headquarters Station: 444 Andover Park East • Tukwila. Washirwton 08188 • Phone: 12061 575 41)4 • Far 12(M) VS :44W
.PARATCi PERNirr
lilt :QUiRE° FOR.:
r►�{tECHAt`�IICAL
)ELECTRICAL
❑ PLUMBING
a GAS PIPING
CITY OF I,i ?'11:;99..A
BUILDING DIVISION
C..
FI�C CQPY —�I
understand that the Plan Check approvals are
;:.ohiect to errors and omissions and approval of
any 01.:sns does not authorize the Receipt on -
:0: code or ordt ed.
tractor's copy of a pproved plans acknowledg
Is3 P R OF p
DE,C 1 1999
Ityek
F31Jiw' ING DIVISION
L
CONCRETE I AGE.
1thFS= Tii.F.FFNERS Wii kL L� :A1 *CT
0008 OPFNIhG
9'- G' X 7 - 0�
2i' -O
SIDE VIEW
L i SPRA:' ENCLOSURE TECHNOLOGIES
E 1 1C0 - A EAST MAIN STREET
ONTARIO, CA_IFORN;A 91761
ELECTRICAL REQUIREMENTS
�; swam EQUIP. VOLTS FULL LOAD AMPS
i l ",10 : (tot! —TUBE L1Gs+T FrX URES %20 V AMPS PER FL�� ;ft:
i (7] 7 44 7 FAQ: 3. OiC�t 3 PH 1 206 - 240 / 50 J E.6 a 4/. AMPS
ACCESS I.00R
- PRODUCT ENTRANCE DOORS
WITH (20) 20' x 20' INTAKE FILTERS
30' DIAMETER TUBE-AXIAL
FAN MIN NON - SPARKING 8L D
A.)LC.A CERTIFIED
POWERED BY A 214P 3 PHASE
AT .2 STATIC PR CI M.
FRONT VIEW BACK VIEW
FRONT FLOW
AUTOMOTIVE SPRAY BOOTH
MODEL: ST91 4.24Fr
M 99•D
SPECIFICATIONS
• ALL PANEL FLANGES CUTSI!)E
OF THE i1Nr.
• ALL PANELS CONSTRUCTED
WITH 18 GAUGE GALV. STEEL
• BASE OF UNIT MOUNTED ON
GALVANIZED FLOOR RAPS
• ACCESS DOOR CAN BE LOCATED
i}N EITHER SIDE OF THE UNfT
• INSIDE PANEL SEAMS ARE SMOOTH
• BASE OF DOORS SEALED
WITH NEOPRENE STRIPS.
• LIGHT FIXTURES MOUNTED ON
CLEAR TEMPERED GLASS
• BRIXON LATCHES ON ODORS
• 16 CELL ARRESTOR C- 1418F
EACH CELL 20 X 20 X 2
• UNIT FACTORY BUILT TO MELT'
OR EXCEED BOCA.
OSHA, ac NFPA — 3:3
. JOB NAME t DATE
tf'Y OF TUJMJEL
.3V 22
PERter CENTER
6/10
duct
t aue galv. N
existing wood
composition roof
1 '
• • •
1" gap between carnbus
able roof material and
ti re wrap
inaulated fire —
wrap, 20 ,ga . with
inon insulaLion,
SMALLER CRIMPED END
=Ems INTO UN-BEADED
ENT AND IS TER SCREWED
TOGETHER
USE :1/8" BOLTS PROVIDED TO
BOLT COMPANION FLANGE TO TOP
of PAN. DRILL TOP OF BOOTH OR
FAN WONTING BASE WITH 3/8"
liOtES AND MOUNV IN A SIMILAR
FASHION
iliCLOSURE IECFNOLOGIES
! 1 04-i EAST II,M3 STREET
OKRRIO, CALIFOKNIA 91761
4-
0
6
FAN BASE
DUCT DETAI L
i WITH BUTTERFLY
CAP
BUTTERFLY VALVE
EXHAUST AND RAIN
CAP
counter
ashng
cable ties 3/16" wire
cable mounted La 1"
eye bolts typ of 4
(recommended, not aupplizd )
DUCT DETAIL COMPLIES WITH
UNIFORM MECHANICAL CODE
SECTION 1107
UNIFORM FIRE CODE SECTION
45-206
NFPA-33 & 91
File:DUCTDET3
JOB NAME DATE
ClIfUleN
AV'P
DEC 1999
---
b
90 -0"
35 -0"
WORKBENCH
SHOP
U 0
O
wz
J Q
a �
ACCESS
POOR
WORKBENCH
WORKBENCH
WORKBENCH
WORKBENCH
27 0"
MAIN
ENTRANCE
�-- 14' -0"
C
EXHAUST
INSTALLATION
AREA
Building Plans
biA
aaIr ,C _
EXHIBIT A
FLOOR PLAN
O
U
c11‘( aV a E p
APP R.
DEC ? 1999
BUILDING DIVISION
•
c
LEGAL DESCRIPTION AND SITE PLAN
Lot 1 of Short Plat No. 79- 26 -SS, according to the Short Plat survey recorded under
King County Recording No. 8004240503, and as amended by boundary line agreement
recorded under King County Recording No. 8210010941;
TOGETHER WITH AN easement for ingress, egress and utilities as set forth in Short Plat
No. 79- 26 -SS;
Situate in the County of King, State of Washington.
EXHIBIT B
•
•
Hi Ken,
•
•
•
•
•
A1 0234
,,o,,..„„,,.,,t,,,,,,.5..,,y.
., t ji
To: Ken Nelson
Company:
From: Todd Likens
RE:
• •
• •
Fax: 206 - 431 -3665
Date: 12/23/99
Pages: 3
•
(I . 1 BOX 98498
La kewood, WA 98498 -0498
Phone — (253 )-589 -3144
Fax — (253) -589 -3145
•
O Urgent ❑ For Review ❑ Please Comment 0 Please Reply 0 Please Recycle
• •
As discussed, I am attaching a brief explanation of our plan to put up sheetrock, along with,the original
drawing from our Permit application (Permit Number M99- 0234).
Please let me know if you have any questions or need anything further.
Thank you.
Id WdSt':titi 6 £Z 'oaa 6289 S£8 90Z : '0N 9•0Hd
DEC 2 3 1999
COM MUNITY
DEVE LOPMEN'T
•oui 'swal.sAS a lyde.a9 :.Woad
FROM : Graphic Systems, Inc, PHONE NO. 206 835 6829
�:v..r�. t l•. I
•• r 1
BONYJ.N3
NiV N
HON39* OM
HON9eHUOM
L _-_, �N3liNdOM
HoN38XdOM
V Oo Q
C
O
w
dOHS
Dec. 23 1999 11:46AM P2
0
0
m
HON39)iNOM
,.0•ss
..0.06
Graphic Systems, Inc.
Permit Number. M99 -0234
At the location shown on the attached drawing (see *) we intend to attach two layers of
Type X, 5/8" sheetrock to the plywood wall (staggered) to insulate it from the paint
booth, which shall be located not less than 18" from the wall. The sheetrock will be
attached at least 3 feet above and to each side of the paint booth.
£d Wd9b:titi 666ti £Z '° a
6Z89 S£8 . 90Z : ON BNOHd, 't t !Du/ / ' •sw2 ;sFis Q p . de -tJ :: W021.d
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M99 -0234 DATE: 11 -22 -99
PROJECT NAME: GRAPHIC SYSTEMS INC.
XX Original Plan Submittal
Response. to Incomplete' Letter. #
Response to Correction Letter # , Revision # _After Permit Is Issued
DEPARTMENTS:
Building Division III Fire Prevention
11 /floc 1 - `fig
Public Works n Structural n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete U Incomplete
Comments:
TUES /THURS ROUTING:
Please Route Structural Review Required No further Review'Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: (ten days)
Approved n Approved with Conditions
\PRROUTE.DOC
5/99
Planning Division
Permit Coordinator
4;(�.- .,�:, �. ... .ry1�ir� %j 5.W°f, �;f +''.�f ftt #�+'+X2- ii ?��::s7,}
n
■
DUE DATE: 11-23-99
Not Applicable n
DUE DATE 12 -21-99
Not Approved (attach comments) 17
REVIEWER'S INITIALS: DATE:
CORRECTION DETERMINATION: DUE DATE
Approved n Approved with Conditions ❑ Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
Fire Department Review
Control #M99 -0234
(511)
Dear Sir:
City of Tukwila
Fire Department
December 1, 1999
Re: Graphic systems, Inc. - 4493 South 134th Place
Thomas P. Keefe, Fine Chtef
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. Extend sprinkler protection to the spray booth
including plenum and duct.
2. Water supply to spray booth sprinklers shall be
controlled by a sectional control valve.
3. All valves controlling the water supply for automatic
sprinkler systems and waterflow switches on all sprinkler
systems shall be electrically supervised. (City Ordinance
#1742)
4. All new sprinkler systems and all modifications to
existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or
modification. New sprinkler systems and all modifications
to sprinkler systems involving more than 50 heads shall
have the written approval of the W.S.R.B., Factory Mutual,
Industrial Risk Insurers, Kemper or any other
representative designated and /or recognized by The City of
Tukwila, prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved
drawings. (City Ordinance #1742)
All sprinkler system plans, calculations and the
contractors Materials and Test Certificates submitted
to The Tukwila Fire Prevention Bureau must be stamped
with the appropriate level of competency seal. (WAC
212 -80)
John W. Rants, Mayor
U ..,InunwFnrY. CfnNnn. AAA Anrinunw D9cG L'nct . T,dnlilh WichInatnn O11112R • Dhiursa. 19M1 C7s.AAfA • Paw. 12M1 S7S.4A1O
Page number 2
City of Tukwila
Fire Department Thomas P. Keefe, Fire Chief
5. All new fire alarm systems or modifications to
existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence
until a fire department permit has been obtained. (City
Ordinance #1742) (UFC 1001.3)
6. Spray equipment shall be interlocked with spray booth
ventilation equipment.
7. Air movement shall be a minimum of 100 lfp.
8. Provide a minimum 4A 40BC extinguisher within 30' of
your spray booth. (UFC standard 10 -1)
Portable fire extinguishers shall be securely
installed on the hanger or in the bracket supplied,
placed in cabinets or wall recesses. The hanger or
bracket shall be securely and properly anchored to the
mounting surface in accordance with the manufacturer's
instructions. The extinguisher shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor and the clearance between the
bottom of the extinguisher and the floor shall not be
less than 4 inches.
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher ", with an arrow pointing to the unit.
(NFPA 10, 1 -6.3) (UFC Standard 10 -1)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1 -6.5)
9. An electrical permit from L & I is required.
10. A notice of construction permit must be obtained from
the Puget Sound Air Pollution Control Agency prior to the
installation of the spray booth. The permit shall be
posted at the jobsite.
John W. Rants, Mayor
ue��r,. u�rFnrc cF�Nnn. AAA A nrinvnr r • ! . ' , c t • TuLur112 Wachlnotnn O J U R R • Phnno• S7cd4Ad • I . 12(M) S7S44.30
Yours truly,
CM
City of Tukwila
Fire Department
Page number 3
Contact The Tukwila Fire Prevention Bureau to witness all
required inspections and tests. (UFC 10.503) (City
Ordinance #1742)
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Headauarters Station: 444 Andover Park East • Tukwila. Washlnkton 08188 • Phone 1206) 575-4404 • Fax• 1206) 575-4430
P625-052-000 (8/97)
DEPARTMENT OF LABOR AND INDUSTRIES.
REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
REGIST., EXP.. DATE
CCO1 ;GRAPHS *035QF 11/01/2000
;EFFECTIVE-DATE= 11/06/199
GRAPHIC SYSTEMS
850 NW 61ST ST
SEATTLE WA 98107
1 :n25 -052 -11111 11■171
- -- Detach And Display Certificate
REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
REGIST. # EXP. DATE
CCO1 GRAPHS *035QF 11/01/2000
EFFECTIVE DATE 11/06/1997
GRAPHIC SYSTEMS
850 NW 61ST ST
SEATTLE WA 98107
Signature
Issued by DEPARTMENT OI LABOR AND INDUSTRIES
Please Remove
And Sign `
Identification
Card Before
Placing In
13illl'old •