Loading...
HomeMy WebLinkAboutPermit M99-0243 - PRIMESOURCE CORP:w +i ;«+, i'. ,'Y ..,;�.. ♦'' :i , . -: _:... ri w. ... )�:.; i�i:'..� . ?(: .r ^'1t w?: qxT cb'.xay +bi,� ;s,Fx ''[� t+�n' J j+WF". V .71.� ... �< �' e! c3rk.:; ir; �` �tiN: �i.. yisk�:. whl r.. tv+ i' v�. �Ji'.. Y , �.4ltyVfihkY:'i:Jri n re�.'il�J fide' �`); a,.. . t, �k; �ir��u. tG'w;'�W.9 >;ast'ti+@� w +x:b�Kw„�:iK�1'i.'��i laili6 %raFa`�. iifn:nY�? M99 -0243 355 Treck Dr. Primesour City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M99 -0243 Type: B -MECH Category: NRES Address: 355 TRECK DR Location: Parcel #: 022340 -0042 Contractor License No: MACDOM *248J9 MECHANICAL PERMIT UMC Edition: 1997 Valuation: Total Permit Fee: (206) 431 -3670 Status: ISSUED Issued: 12/17/1999 Expires: 06 /14/2000. TENANT PRIMESOURCE CORP Phone: 355 TRECK DR, TLUKWILA, WA 98188 OWNER PRIMESOURCE CORP Phone: (206)575 -1500 15 TWINBRIDGE DR, PENNSAUKEN NJ 08110 CONTACT ERIC BENNETT Phone: 206 -768 -3968 7707 DETROIT AV, SEATTLE, WA 98106. CONTRACTOR MACDONALD MILLER CO Phone: 206 763 -9400 7717 DETROIT SW, SEATTLE, WA 98106 *** * * * * *** * * ** * ** ** k * * * ** * *•k *•k** k * *•k *•* ****** ** *•k* * ** * *** * * * * * ** * *** ** * **** Permit Description: INSTALL OWNER SUPPLIED EQUIPMENT. IN COMPUTER ROOM. EQUIPMENT IS AN AIR HANDLING UNIT. AND AN AIR COOLED CONDENSER. • 4.,311.00 59.81 ******************** �k *****************• k**** * *, * * * * ** ** * * * * *** * * * * * ** * * * * ** J.: -7_07c/ Permit Center Q thorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied .with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: Print Nanie: p-etC- R 8 /RA 1 N i7`7 Date: 1 /7-if `j Title: r/J4TR This permit shall become null and void if the work is not commenced within 180 days from the date of issuance', or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 355 TRECK DR Permit No: M99- -024: Suite: Tenant: PRIMESOURCE CORP Status: ISSUED. Type: B -MECH Apia 1 i ed 12/03/1999 Parcel #: 022340- -0042 Issued: 12/17/1999 klk• kk• k k• k*• k• k• k• k* k• k• kk** k• k• kk•k*• kk• k• k*• k• kA*• k k k• kk• kk A*• k k• k k* kA k• k• k• k*• k' k•k *•k•k**•k *•k**•k•ktitit•k•k Permit Conditions: 1. 'Readily accessible required. 2, 'Electrical permits shall be obtained' through the Washington State Division of Labor and Industries and all electrical work w i l l be inspected by that agency (248-6630). :a, No changes wil l , be made to the plans unless approved by the Engineer and the Tukwila Building Division 4. All permits, inspection records,, and approved plans :shall be available at the iob site prior to the start of any, con- struction. These 'documents are to be maintained and avail- able until final inspection :.approval is granted: 5. All construction to be done, in conformance with approved plans and requirements of the Uniform Building Code: (1997. Edit ion) as amended, ::Uniform, Mechanical. Code (1997 Edition) and Washington State Energy Code (1997 Edition). G. ;Validity : of Permit. The issuance of a permit or approval. of ;plans, specifications, and computations shall not be con- strued� to be a permit for, 'or ':an` approval of, any violation of any of the provisions of the bu n lding code or of, any other ordinance: of the .jurisdiction, No permit presuming to give authority to violate or.' cancel the provisions of this code shall '. be valid. 7. Manufacturers installation instructions required on site . for - the '.- building inspectors review.`. access to roof mounted equipment As Project Name /Tenant: pt i ter.- 5-10U 2 i2 P Value of Mechanical Equj � t: (1 �/ Site Address : ____- City State /Zip: 35.5 7 G EC D R - Tun -�Ie_4 If37B Tax Paxeel ryD, e.1(24. �r� �• ` l�"1� Property Owner: Print name: Phone: ( 59 fi _ 5 7 r Street Address: 52 City State/Zip: Fax 41: ( ) Fax #: ( Zoa ) 76 8 3 , Y c 9 Addr Contractor: i4-C -- D 0.N L D ! `` 7 - 5?- 4<litC- Phone: S ) 704 g ,...s., Street Address: City State/Zip: Fax #: ( ) T r; w /c_ 4 WA- & l6 Contact Person: �' F- 1 C BPlit/N,g. 7 Phon (. 7 68 >4 6 9 Street Address: .q7-. 9X7^2 ir` Auti se,4 -i7 _ City State /Zip: srbblaG Fax it: ( ) v° 7 8 74 7 BUILDING OWNER OR AUTHORIZED AGENT: • - • - Signature: <"'.' �U , �` Date: 12_429 ? Print name: _mi l. C 30 - �A4) S Phone: (mss) 76 ?� 6- Fax #: ( Zoa ) 76 8 3 , Y c 9 Addr City / State/Zip: '� ;n %e. 0, i .4 urn T r; w /c_ 4 WA- & l6 CITY OF TUKWILA Permit Center Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 I OR S1AFF USE ONIY Project'Nu,.r. V\ '" V, Permit Number: Mechanical Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. MECHANICAL PERMIT REVIEW AND APPROVAL REQUESTED: (TO'BEFILLED OUT BY APPLICANT) . Description of work to be done (please be specific): (N 5 TAL 0 1 ..1 g 2 S u Ppz..,rL .D l et) ec Pu7 FZ c90.mil Fceut 7 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be extended more than once. Date application accepted: ►a 3 -�1q 9/7/99 mull nrrndl.tine Date application expires: 1- 3 -' D000 Application taken by: (initials) ✓ Submittal Requirements Floor plan and system layout V / Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504 (e)) Details and elevations (for roof mounted equipment) and proposed screening Heat Loss Calculations or Washington State Energy Code Form #H -15 . H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut- off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical Code 1009). Specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. Structural engineer's analysis is required for new and the replacement of existing roof equipment weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be stamped by a Washington State licensed Structural Engineer. 9/21/99 ,nlscpu.Joc Mechanical Permits COMMERCIAL: Two complete sets of drawings and attachments required with application submittal NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. RESIDENTIAL: Two complete sets of attachments required with application submittal Submittal Requirements New Single Family Residence Heat loss calculations with specifications or Form H - 6. Change -out or replacement of existing mechanical equipment 1 Narrative of work to be done, including modification to duct work. Installation of Gas Fireplace Narrative with specification of equipment and chimney type. If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe condition. NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water heaters or vents being installed or replaced. .AirA*A4>‘:W*.A.A*1:**.A***7lki*X. trITY OF. TUKWILA', WA VICji•Ct—05L1 TRANSMIT h: A A A -A * *!* A: * •A * k .* h A A ,* A Aul: fre * iv,* * A A * A * * * k A: * k * * * * I. * A * iv * * 1: ) 4.. k * ** * A * * A. * * * * TRANSMIT Numb;?r.: R9800U6 Amountt S9A1; 12117/99 11:22 '.PeNmerit Methedt CHEC{ on ACDONALD MILD Init T(.11 • .Permit NO; M99-0243. Tye: 11-MECH MECHANICAL PERMIT Parcel No.t O2340•0042 ,.. Site Addrestlt 3$5 TRUK DR .., ,. l'his P.i.4 5 TcAtsl ALL Pmts.,: 59.,9.1 . . Balancer • •,,00 ,A4,1k A h A- * .1- * * * h.- ,t; A. A A *,.A. * * it* i 14 * . * * * * * A A A: * le A A A 1 t * k * * * * * 1: * * A * * * A ii if *k k * jv ill I; Account Cod4 .r.D .• ...t 000/045 'i•PLAN CHECK - NONKES 000/3221.00 MECHAN.ICAL - NONNI'S 0 Amdunl:• 11,96 971.5 12/2'() 9717 : TOTAL .5941 Proje , , f-1/1 i'/".4.Ce Type of Inspection Addgst-- Date called: Special instructions: Date o a a.m. P.m. Requ R/1/ Phone: re. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO, (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS. Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: Project: y 50 arop oQnspeCti%i: .., 5 A ress: 1 Date called: / 07. ., ,, 1 Spe al instructions: • Date wanted: p.m. Requesteri-- Ancekta) 11 12-0 C 5 / 7 L i INSPECTION NO, pproved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 Corrections required prior to approval. $47,00 RE1NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: ef i Z ,T„. Tr5 ok- Receipt No Date: 12/01/99 17:28 FAX 20676367 • • • Model Number Breakdown BF042A —ASM 042 b Challenger 3000 E = Downflow with Nominal capacity in Econ -O-Coit thousand BTUH Product Description Challenger 3000 is available in three main system configurations: as a split system with an evaporator section and a remote condensing unit, as a self contained system with a scroll compressor located In the room unit and as a self contained chilled water system. All three types are available in upflow or downflow configurations. The standard upfiow configuration is front return. Three -ton units are available in 208 Volts, 230 Volts, 460 Volta and 575 Volts. Five -ton units are available in 209 Volts, 230 Volts, 460 Volts and 578 Volts. The following features are included as standard in all room units regardless of the type of s stem. A frame coil, (V frame on upflows) infrared`huti ter; finned tubular S.S. electric reheat, 2 in. (5cm) filters, Individual high voltage fused protection, fan assembly and the standard microprocessor (SM) control which provides th Liebert SAPS- 8501 -401 Revision 5; 02/12/99 F = Downflow K a Upflow wfth Econ.O -Coil U a Upfiow u... :..: 4 ' � cAit' t N: ii ll i' i! YYJ.. SifGRl. 4 ' it.. V: Y. aYa: iYb\: hzw... lr. rru .iw.•.... « .,......... f ......: . JOHN DONOVAN- CAMPBELL (.. A A = Air Cooled CHALLENGER 3000 60 Hz Status Lights Cooling Heating Humidifying Dehumidifying CITY RECEIVED DEC 3 1999 PERMIT CENTER A A = 460/60/3-phase C = Chilled Water B = 576/60/3 - phass E = Evaporator C m 20&8013 -phase O IN Olycool D = 234/60/3 -phase WG a Water Cooled/ Glycol Cooled Loss of Airflow High Head Local Alarm SM 1001 SM = Sta ndard Microprocessor AM = Advanced Microprocessor AG = Advanced Microprocessor w /graphics temperature set point and sensitivity adjustment, humidity set point and sensitivity adjustment, digital display of temperature, humidity and the setpoints/sensitivities, operating status LED's and Alarm LED's. A software controlled humidifier flush system is incorporated Into this control. Alarm Lights (audible included} High/Low Temperature High/Low Humidity Change Filters UNIT WEIGHT • 50 HZ GO HZ MODELS MODELS LN31.(K01 EIFONE 535 (213 1180803 515 247) 8FONA 555 270 IFONA • ' 510 NI 1180489131 810 391 W071WG 710 (sn 1190650 515 017) 171020 555 pip 8E0010 750 (311) 16 UPFLOW (BU) MODELS 22 irr Pon Dimensional Drawings irtrr • • • . . . . : DOWNFLOW (BF) MODELS 1I2 32irr IHADEDAREA INDICATES :•-• • Off & A IEN ro mar c : c 10 1 1/712 L *.•:'. RIGHT SIDE ACERB REQUIRED • FOR G UNITS . • .. • : .", ‘. • 16)■•.: (TIN 121. • UNIT DIMENSIONAL DATA : • FRONT VIEW : (front return configuration) ; : • PROJECTIONOFDISPiNi • '". • 11121L5/1•Itemen) • • • . • • • , , msinnetiimitcALoUnzr :•LOCATIONThROUGRUNIT. • • UN IT DIM DATA FLOOR CUTOUT DIMENSIONS 8HADEDAREA INDICATES A •• • RECOMMENDED CLEARANCE .• OF34' (NW* BE PROVIDED , ...• FOR CONTACCE913. • RIGHT SIDE ACESS REQUIRED • FOR GLYCOL UNITS • STANDARD PIPING LOCATION OPTIONAL. FLOORSTAND DIMENSIONAL DATA Model Width (D) Depth (E) Height (F) PFC042A -PLO 40 (1016) 18 (457) 31 (787) PFH042•PLO 40 (1018) 18 (457) 31 (787) PFC042A -PHO 53 (1346) 18(457) 36 (914) PFH042A•PHO 53 (1346) 18(457) 38 (914) PFCZ42A -PLO 53 (1346) 18(457) 36 (914) PFC067A -_L0 53 (1346) 18(457) 36 (914) PFHO67A -_LO 53 (1346) 18(457) 38 (914) PFC087A -_110' 53 (1346) 38 (914) 38 (914) PFH067A _HO' 53 (1346) 38 (914) 36(914) PFC267A•_L0' 53 (1348) 38(914) 38 014) Split System 3 -Ton Centrifugal Fan Condensing Unit 1 • 19W (495mm) 2231e ". (567mm) REMOVABLE • ACCESS PANELS 841' (666mm) 0 0 51W 1l 1302mm1 sioNS • O 0IME 461 -� (tteam .:: 4a% • • (1257o E THREADED R 20 e (5t9n(n) W (10mm) Hales For Mule Rigging (1YP• 2 od Each EEnd) (25.4mm) Bracket (samm . Ou • Flange Hanging Minimum Clearance 33' (630mm). • •':This End For Component Access And Removal Split System '• • 5 -Ton Water /Glycol Cooled Condensing Unit ' 30. O 762mm)1 VERALL 24• (810mm) THREADED P00 CENTERS • 30' (782mm) Coillnlet Duct Connection SHADED AREA • • • ' • INDICATES A RECOMMENDED . • CLEARANCE OF 24' 610mm OE PROVIDED FOR COMPONENT' ACCESS AND REMOVAL. AIR INLET • • DUCT CONNECTION: 4211' (11130mm) 4 24W (869mm) CUSTOMER SUPPLIED • THREADED ROOS FOR MODULE SUPPORT FROM ' CEILING (TYP, 4) .. ,. �• W 12.7mm) DIA.HOLES 'FOR MODULE RIGGING (TYPICAL 4 EACH 5I0E) . Hanging Bracket (25.4mm) • 11 (39mm) ••11W (289mm) Blower Outlet • Duct Connection cirstg Electrical Entrance i (394mm) (457mm) .I 4IC (10mm) Hales • For Module Rigging (Pip. 2 Each End). Split System 5 -Ton Centrifugal Fan Condensing Unit .Hanging Bracket Relrl Une Connections • 30' (760mm) r ' overall 24' 810mrn) THREADED ROD CENTERS • .1a" 5W' VE Rp�L O DMEM c. SIO t 49V'' THREADED ROD TERS 46W ' ENTERS (118lmm) (457mm) 'Hanging Bracket'' 14' d 3 � m^ VERAI -�_-; DIMENSIONS • (222mm THREADED ROD CENTER •' AIR OUTLET DUCT CONNECTION •.; '30' (78omm) • •: c (399mm): 4'..: (•.-- THREADED 1341' 314mm'.?.::,',. I ROD CENTERS _ 2614 (e71mm) r q : ' �.,`��i• • ERALL SHADED AREA .:'INDICATES A RECOMMENDED CLEARANCE OF 24• (810mm • • BE PROVIDED FOR COMPONENT ACCESS AND REMOVAL 37 .. a t (960mm) 'g ie . (1067mm) Lee•TYmp Receiver ' L40' (1 w7w • (t9onwn) • Split System Propeller Fan Condensing Unit Propeller Fan Condens ng Unit Dlmenslans — Inches (mm) 'Units have vertical air discharge 22vP (57 6mm)t OVERALL 21w . (546mm) 18w ( • THREADED CENTERS 18' (610mmt (457mm) Split System 3 -Ton Water /Glycol Cooled Condensing Unit .Self Contained System Air Cooled Condenser;. or Drycooler site �i.\ •'4341x' (1306 mm) All Voltages Are 3 Phase Unless Noted Otherwise Self Contained II Fan Coil & Chilled Water II 3 Ton B• 042A, 046WG II 5 Ton B• 067A, 071 WG, 061 G 11 3 Ton B• 036E, 068C 11 5 Ton B• 060E. 102C 1 208 1 230 I 460 I 575 It 208 1 230 I 460 1 575 11 208 I 230 I 460 I 575 II 208 I 230 I 460 I 575 1 With Reheat & Humidifier (Infrared or Steam Generating) Motor .75 HP (.56 kW) 1.5 HP (1.1 kW) .75 HP (.56 kW) 1.5 HP (1.1 kW) FLA 42.0 40.3 20.0 17.5 66.6 63.6 32.3 25.1 41.4 37.5 19.0 17.5 60.6 55.4 28.1 24.6 WSA 51.7 49.7 24.6 21.9 81.8 78.2 39.7 30.9 51.7 46.9 23.7 21.9 75.7 69.2 35.1 30.8 OPD 50 50 25 20 90 80 40 30 60 50 25 25 80 70 40 35 Motor 1.0 HP (.75 kW) 2.0 HP (1.5kW) 1.0 HP (.75 kW) 2.0 HP (1.5kW) FLA 42.9 41.1 20.4 17.8 68.4 65.2 33.1 25.7 42.3 38.3 19.4 17.8 62.4 57.0 28.9 25.2 WSA 52.9 50.5 25.1 22.2 83.6 79.8 40.5 31.5 52.9 47.9 24.2 22.2 78.0 71.2 36.1 31.5 OPD 60 50 25 20 90 80 45 35 60 50 25 25 80 80 40 35 Humidifier Only (Infrared or Steam Generat ng) Motor .75 HP (.56 kW) 1.5 HP (1.1 KW) .75 HP (.56 kW) 1.5 HP (1.1 kW) FLA 30.3 27.8 14.0 13.9 38.3 35.6 18.4 17.4 16.4 13.9 7.2 8.5 19.0 16.3 8.4 9.5 WSA 33.8 31.3 15.7 15.2 43.1 40.4 20.9 19.4 20.5 17.4 9.0 10.6 23.7 20.4 10.5 11.9 OPD 45 45 20 20 60 50 30 25 20 15 15 15 25 20 15 15 Motor 1.0 HP (.75 kW) 2.0 HP (1.5kW) 1.0 HP (.75 kW) 2.0 HP (1.5kW) FLA 31.2 28.6 14.4 14.2 40.1 37.2 19.2 18.0 17.3 14.7 7.6 8.8 20.8 17.9 9.2 10.1 WSA 34.7 32.1 16.1 15.6 44.9 42.0 21.7 20.0 21.6 18.4 9.5 11.0 26.0 22.4 11.5 12.6 OPD 45 45 20 20 60 60 30 25 20 15 15 15 30 25 15 15 Reheat Only Motor .75 HP (.56 kW) 1.5 HP (1.1 kW) .75 HP (.56 kW) 1.5 HP (1.1 kW) FLA 42.0 40.3 20.0 15.5 66.6 63.6 32.3 25.1 28.1 26.4 13.2 10.1 47,3 44.3 22.3 17.2 WSA 51.7 49.7 24.6 19.1 81.8 78.2 39.7 30.9 35.1 33.0 16.5 12.6 59.1 55.4 27.9 21.5 OPD 50 50 25 20 90 80 40 30 40 35 20 15 60 60 30 25 Motor 1.0 HP (.75 kW) 2.0 HP (1.5kW) 1.0 HP (.75 kW) 2.0 HP (1.5kW) FLA 42.9 41.1 20.4 15.8 68,4 65.2 33.1 25.7 29.0 27.2 13.6 10.4 49.1 45.9 23.1 17.8 WSA 52.6 50.5 25.1 19.4 83.6 79.8 40.5 31.5 36.2 34.0 17.0 13.0 61.4 57.4 28.9 22.3 OPD 60 50 25 20 90 80 45 35 40 35 20 15 70 60 30 25 I Without Reheat & Humidifier Motor .75 HP (.56 kW) 1.5 HP (1.1 kW) .75 HP (.56 kW) 1.5 HP (1.1 kW) FLA 17.0 16.7 8.2 6.5 25.0 24.5 12.6 10.0 3.1 2.8 1.4 1.1 5.7 5.2 2.6 2.1 WSA 20.5 20.2 9.9 7.9 29.8 29.3 15.1 12.0 3.9 3.5 1.7 1.4 7.1 6.5 3.2 2.6 OPD 30 30 15 15 45 45 25 15 15 15 15 15 15 15 15 15 Motor 1.0 HP (.75 kW) 2.0 HP (1.5kW) 1.0 HP (.75 kW) 2.0 HP (1.5kW) FLA 17.9 17.5 8.6 6.8 26.8 26.1 13.4 10.6 4.0 3.6 1.8 1.4 7.5 6.8 3.4 2.7 WSA 21.4 21.0 10.3 8.1 31,6 30.9 15.9 12.6 5.0 4.5 2.2 1.7 9.4 8.5 4.2 3.4 OPD :4.35 30 15 15 50 50 25 20 15 15 15 15 15 15 15 15 18 The above values were calculated per UL Standard 1995. FLA= Full Load Amps (Input Amps) WSA= Wire Size Amps (Minimum Supply Circuit Ampacity) OPD= Maximum Overcurrent Protective Device Size *F= Downflow U= Upflow E= Downflow with Econ -o -coil K= Upflow with Econ•o -coil Electrical Data 11 3Ton B° 042A, 046WG 15 Ton B• 087A 071WG, 081G 208 1 230 1 460 1 575 11 208 I 230 1 460 I 575 'With Reheat & Humidifier (Infrared or Steam Generating) Motor .75 HP .56 kW) 1.5 HP 1.1 kW 067A FLA 55.3 51.4 25.8 NA 79.9 74.7 38.1 NA WSA 65.0 60.8 30.4 NA 95.1 89.3 45.5 NA OPD 70.0 60.0 30.0 NA . 100.0 90.0 50.0 NA Motor 1.0 HP (.75 kW Centrifugal Fan (MMC) 2.0 HP (1.5 kW 085A 065A FLA 58.2 52.2 26.2 NA 81.7 76.3 38.9 NA WSA 65.9 61.6 30.9 NA 96.9 90.9 46.3 NA OPD 70.0 60.0 30.0 NA 100.0 100.0 50.0 NA Reheat Only Motor .75 HP .56 kW 17.9 1.6 HP 1.1 kW 26.8 FLA 42.0 40.3 20.0 NA 86.6 63.8 32.3 NA WSA 51.7 49.7 24.8 NA 81.8 78.2 39.7 NA OPD ' 50.0 50.0 25.0 NA 90.0 80.0 40.0 NA Motor 1.0 HP .75 kW 2.0 HP 1.5 kW FLA 42.9 41.1 20.4 NA 68.4 65.2 33.1 NA WSA 52.6 50.5 26.1 NA 83.8 79.8 40.5 NA OPD 60.0 50.0 25.0 NA 90.0 80.0 46.0 NA 1 I 3 Ton 11 5 Ton 1 I Air Cooled 11 208 1 230 1 460 1x208 230 460 575 Prop Fan (PFC) 042A 042A 042A 067A 067A 067A 087A FLA 15.3 15.3 7.1 22.7 22.7 11.7 9.1 WSA 18.8 18.8 8.7 27.5 27.5 14.2 11.1 OPD 30.0 30.0 15.0 40.0 40.0 20.0 15.0 Centrifugal Fan (MMC) 040A 040A 040A 066A 085A 065A 066A FLA 20.9 20.9 10.0 28.9 28.2 13.0 10.6 WSA 24.5 24.5 11.7 34.3 33.8 15.4 12.6 OPD 35.0 35.0 15.0 50.0 50.0 25.0 20.0 Water /Glycol (MMC) 044WG 044WG 044WG 069WG 069WG 069WG 069WG FLA 14.3 14.3 6.7 21.4 21.4 9.6 7.9 WSA 17.9 17.9 8.4 26.8 26.8 12.0 9.9 OPD 30.0 30.0 15.0 45.0 45.0 20.0 15.0 11 3Ton 11 5Ton 3Ton 11 STon Scroll Compressor 208 1 230 1 460 I 575 11 208 1 230 I 460 1 575 GLYCOL. Drycooler & Pump DSF Model 059 1 069 1 069 1 069 109 I 109 109 1 109 Pump HP 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 FLA 7.9 7.6 3.9 3.1 7.9 7.6 3.9 3.1 WSA 9.1 8.8 4.5 3.6 9.1 8.8 4.5 3.6 OPD 20.0 20.0 15.0 15.0 20.0 20.0 15.0 15.0 GLYCOOL Drvcooler & Pump DSO Model RLA LRA 109 109 109 109 Pump HP 10.8 8.4 46.9 40.8 1 1/2 1 1/2 1 1/2 1 1/2 FLA 9.7 9.2 4.6 3.5 WSA 11.1 10.5 5.3 4.0 OPD 25.0 20.0 15.0 15.0 11 3Ton 11 5Ton 1 208 1 230 1 480 1 575 11 208 I 230 1 460 1 575 Scroll Compressor RLA 13.9 13.9 8.8 5.4 19.3 19.3 10.0 7.9 LRA 88.0 88.0 44.0 35.0 123.0 123.0 62.0 50.0 Main Fan Motor .75 HP (.56 kW) 1.5 HP (1.1 kW) RLA 3.1 2.8 1.4 1.1. 5.7 5.2 2.6 2.1 LRA 19.0 18.8 8.4 6.6 35.9 31.2 15.6 12.6 Motor 4.0 1.0 HP 3.6 (.75 kW) 1.8 1.4 7.5 2.0 HP 6.8 (1.5 kW) 3.4 2.7 RLA LRA 24.8 21.6 10.8 8.4 46.9 40.8 20.4 18.2 L 11 3 Ton 11 5 Ton 1 IF?Il<FI7 Fi 1 1 11E3111•7011tLI7WIFf IDSF (3 Phase)I1 089 1 069 I 069 1 089 11 109 1 109 I 109 1 109 1 1 FLA 11 4.8 1 4.8 1 2.4 L.12 j112171111111112131111F42111111X11 I DSF (3 Phase)11 I 1 OPD ., I 1 SEVIS IIiLF7i1a-1 I FLA 11 I 1 15.0 I 11 4 1 4 1 2 1 1,4 1 95•F(35•C) Amblent (3 Phase) CSL- 083L/CSL•104L 1 208 1 230 I 460 1 575 FLA 4.0 4.0 2.0 1.4 WSA 5.0 5.0 2.5 1.8 OPD ., 15.0 15.0 15.0 15.0 I 95 °F(35•C) Amblent (1 Phase) 1 CSF•083L/CSF•104L 120 FLA 4.8 4.8 2.4 1.9 WSA 8.0 8.0 3.0 2.4 OPD 15.0 15.0 15.0 15.0 1 All Alr Cooled Models Volts 120 230 Watts/Pad 150 150 Total Amps 1.25 0.85 WSA 1.6 0.8 OPD 15 15 • { Scroll Compressor and Main Fan for comparison purposes only) • Condensing Unita (3 Phase Fan Speed Control Condensers Lee•Temo Condensers Notes: 1. Pump and Drycooler powered from same 3 phase feeder. 2. FLA = Full Load Amps. WSA s Wire Sizing Amps. OPD = Maximum Overcurrent Protection Device. RLA = Rated Load Amps 3. Values shown are for primary vendors • may change slightly for different source of supply. 4. All Voltages are 3-Phase unless noted otherwise. 1 1 3/4 HP FLA (3 se ) Pha I 1 1 1/2 HP FLA (3 Phase) 1 Drycooler & Pump Pkg. • 95'F (35 °C) Amb Self - contained with SCR Reheat 'Note: For Fan coil units with SCR Reheat see Standard Fan Coil Electrical Data Tables Drv coolers 'DOS (or 000 for 480 volt) dry cooler Is required whon a duel pump package Is specified Pumps Lee Temp Receiver Heater Pads 1 208 1 230 1 460 1 675 1 Separate electrical source required for continuous operation of silicone rubber heater pads for Lee -Temp. S stem T .8 Self -Co r : • Outdoor Prop -Fan Condensin a Unit Indoor Centrifugal Condensin , Unit , Indoor Unit BF /BU 042A - 1 =U 087 [. /BU 036E BF/BU BF/BU . • 0E BF/BU 036E BF/BU 06 1 *Net Ca.eclt Data - Standard Air Volume 80'F DB -67'F WB (26.7'C OB- 19.4'C WB) 50% RH 1 ® ® � © crjmi� = = sMi Total 2,100 12.3 64,900 19.0 40,70 11.9 65,000 19.1 39,800 11.7 65,000 Sensible ,500 10.1 53,900 15.8 34,000 10.0 I 53,900 15.8 33,700 9.9 53,90 75'F DB- 62.5'F WB (23.9'C DB- 18.9'C WB) 50% RH Total 3 200 11. 60,600 17.8 37,600 1.0 60,300 17.7 36,900 10.8 60, .0 Sensible 3 ,400 9. 52,200 15.3 52,100 15.3 32,500 9.5 5 00 15.3 75'F DB -61'F WB (23.9'C DB- 16.1'C WB) 45% RH Total 3: 00 11 60,500 : 60,300 { 17.7 37,600 11.0 .0 •1 1 Sensible 35 : 0 0 r 60,500 117.7 17.7 38,200 11.2 60,300 17.7 37,600 11.0 , 60,400 72'F DB -60'F WB (22.2'C DB- 15.5'C WB) 50% RH Total 37, • r' 11.0 58,100 17.0 35,900 10.5 ,700 16.9 I 35,100 10 Sensible 32, rr 51,100 15.0 32,000 9.4 51 .00 51,000 72'F DB- 58.6'F WB 22.2'C DB- 14.8'C WB 45% RH j Total 38,21.2 58,400 17.1 36,700 58,0i,• 36,100 I ' 58,100 ®' � Sensible 210 400 700 0 : 00• 0 100 0. : 100 Net Ca.acit Data - O.tional Air Volume NMI _ 80'F DB 67'F WB (28.7'C DB- 19.4'C WB) .50% Total 42,80' 12.5 64,200 18.8 41 300 64,300 ' Sensible 39,00 11.4 54,800 16.1 54,800 no ' 75'F QB- 62.5'F WB (23.9'C DB- 16.9'C WB) 50% RH Tatel 39,800 11.7 59,900 17.6 40,000 11.7 59,600 = 200 11.5 59,700 17.5 Sensible 37,60�. 11.0 53,000 15.5 40,000 11.7 52 900 15 5 39,200 11.5 52,900 75'F DB -61'F WB (23.9'C DB- 16.1'C WB) 45% RH Total 41,20 12.1 60,200 17 6 40,000 11.7 60,100 00 11.5 60 100 Sensible 41 20 1 12.1 60,200 ! 40,000 11.7 • 0 100 ' 00 11.5 •: 100 72'F DB -60'F WB (22.2'C DB- 15.5'C WB) 50% RH Total 39,7 57,400 16.8 38,300 11.2 { 57,000 1.1 . 57,000 Sensible 39,7 - 1 51,900 { 15.2 38,300 11.2 51,700 1 11.0 51 700 72'F DB- 58,8'F W 5 22.2'C DB- 14,8'C WB 45% RH 58,000 ®: 38,300 ® '/ Total Sensible 0 0 0 � 39 00 lilt 300 • 500 � 1. s :ir 800 Fan Data Blower Al2x9A " �� -__ : • - _ __- Std Air CFM (CMH) 1800 (3060) 2800 4760 1800 2300 IMENILIFIZ' 306 � 3910 - - (.62) 3000 5100 Std Fan Motor HP k � 314 .56 O •t Alr CFM CMH 1 300 391 1 3000 5100 11 MIII NIIITIM 2300 3910 11111E]11 3000 5100 2 1.5 O•t Fan HP k ExtStaticln.WG Pa If I [$'11' -N r 6.67 .62 (.62) Eva•orator Coll A- Frame - BF V- FRAME - BU __. 6.67 .62 .. -_ _ _ . .. ... ...... (.62) . . _..._ -. -.. 6.67 Face Area Ft.2 (m2) Rows 3 Face Vel - FPM M/S 255 1.3 405 2.1 25 1.3_ 405 2.1 255 1.3 41 Electric Reheat 2 Sta• a Stainless Steel Fin Tubular Ca • acl -- BTU /H K Includes motor heat 33 400 9 56 200 WE 400 9 56 200 15 33 400 9 56 20 [Hot Water Reheat 180'F (82.2'C E.W.T. 75'F 23.9' C E.A.T. - S andard alr vol er o•tIonal fan motor. _ Ca pacity -- BTUIH (kW), Includes motor heat 71,400 • - 1 88,700 (26.0) 1,400 (20.9) 88,700 (26.0) 71,400 (20.9) 88,700 (26.' Ftow Rate -GPM (Us} 5 ' .32) 1 5.0 (.32) 5.0 (.32) , 5.0 (.32) 5,0 (.32) 5.0 (.32) Pressure Oro - FT. (kPa) •. • (50.4) 1 16.9 (50.4) ! 16.9 (50.4) 16.9 (50.4) 16.9 (50.4) 16.9 (50.4) Air Copied Data • The net capacity data has fan motor heat factored In for all ratings and the entering air condflion of 72'F (22.2'C) 60% R -I Is the standard rating for ASHRAE 127.1988. " NOTE: Some options or combinations of options may result In reduced airflow. Consult factory for recommendations. • System Type Se If-Contained Outdoor Prop-Fen Indoor Centrifugal Condensing Unit Condensing Unit Indoor Unit BF/BU 042A BF/BU 067A BF • U 036E _ BF/BU 060E 1 BF/BU 036E BF/BU 060E =IL Infrared Humidifier Ca paclty-Lbs/Hr(Kg/Hr) ( ) 11 (5) i1 U ( ) ( ) 4.8 4.8 4 8 4.8 4.8 4.8 Steam Generat(n a Humldifler MIN IIIIIIIIIIIII Capacity - Lbs/Hr (Kg/Hr) ( ) 11 (5) 11 5 11 5) 11 5 11 (5) Kw 3.9 3.9 Filter - 20% Efficiency 1110111111111k Size - In. 28..x29.5x2 28.5x29.5x2 28.5x29.5x2 28.5 • 9.5x2 28.5x29.5x2 28.5x29.5x2 Size - mm 724 749x51 724x749x51 724x749x51 724x7. • 51 724x749x51 724x749x51 Effective Surface Area - sq. ft. (ma) 24. ( ) 24.1 (2.2) 24.1 2.2 24.1 2. 24.1 2.2 24.1 2.2 Connection Sizes Chellenger3000 Unit Liquid Line 3/8 s D CU 1/2 OD CU 5/8 -18 FEM 1/2 OD CU 5/8 -18 FEM 1/2 OD CU Hot Gas Line 5/8 0 II CU 7/8 OD CU N/A N/A N/A N/A Suction Line N/ WA 1-1/8 - 12 FEM 1 1/8 OD CU 1-1 • - 12 FEM 1 1/8 OD CU Humidifier Supply Line 1/4 0 I CU 1/4 OD CU 1/4 OD CU 1/4 OD CU 1/4 • D CU 1/4 OD CU Condensate Drain Line 3/4 F T 3/4 FPT 3/4 FPT 3/4 FPT 3/4 -T 3/4 FPT Cond, Alr 05'F 35'C AMB Model CS-08 CS-083L PFC 042A PFC 087A MMC 040 .11 Ni 1 (.75) MMC 065A 2(1.5) Motor HP (kW) 3/4 (.56 3/4 (.56) 1/5 (.15) 1/2 (.37) Face Area Sq. Ft. (m 11.1 (1.0 ■ 11.1 (1.03) 7.7 (0.72) 10.5 (0.98) 4.6 (0.43) 7.6 (0,71) Rows 2 2 2 3 4 Ext Static in. WO (Pa) 0.5 (125) 0. 125) CFM (CMH) 2000 (3398) 3600 (. ) Liquid Line Connection 5/8 OD CU 5/8 00 CU 48 -18 MALE 1/2 OD CU 5/8 -18 MALE 1/2 OD LJ Hot Gas Connection 7/8 OD CU 7/8 OD CU N/A N/A N/A N/A Suction Line Connection N/A N/A 1-1/8 -12 Male 1 1/8 OD CU 1-1/8 - 12 Male 1 1/8 OD CU • ueoert Corporation Liebert is the world's leading manufacturer of environmental control and power conditioning systems for data processing applications. Regardless of the application from small spot coolers through sophisticated water chillers, Liebert products are designed to c. maximum precision, reliab lrty, and energy efficiency. The commitment to quality is a basic design criteria at Liebert Corporation. This is demonstrated In every phase of the developmental process, from extensive product engineering through stringent quality control. Now, the Liebert standard of excellence is extended to the heat refection needs of the industry. We thank you for selecting Liebert and are confident you will find these products represent a new standard of excellence in the areas of product quality and customer service. Liebert Heat Transfew AC CONDENSER MODEL NUMBERS Optional Disconnect Switch C = Condenser - -- S Single Refrigerant Orcuil D = Dual Refrigerant Circuit M = Multi- Refrigerant Circuits C D F = Fan Speed Control L =Main Control C = No Control P = Pressure Fan Cycle T = Ambient Fan Cycle S = Special Liebert Heat Transfer Liebert Center 100,000 sq. ft, facility located in Delaware, Ohio 1 0 8 L Condenser Model Size When used indicates: L = enhanced fins C = corrugated fins Voltage Characteristics Code Letter Voltage Phase Hertz P! 208/230 1 60 _ Z' 460 1 60 V• 575 1 60 Y 208/230 3 60 A 460 3 60 B 575 3 60 'ran Speed Contro Only. 'ransformer regwred'or 575V. • FEATURES AND( 7ENEFITS Liebert Air Cooled Condensers CONDENSER The low- profile direct drive propeller fan type air cooled condenser uti- lizes either one or multiple separate refrigeration circuits. Each balances the heat rejection of the corre- sponding compressor to match the ambient temperature of the job. Constructed of aluminum with a copper tube aluminum fin coil, the unit is quiet and corrosion resistant. QUIET - LINE CONDENSERS Quiet -Line condensers can help your facility meet the strictest noise codes and do so at less cost than traditional condensers with acoustical shielding. EASY INSTALLATION AND SERVICE The condenser is quickly and easily installed, because all internal wiring Is completed at the factory with only electrical connections to be made at the job site. Your choice of five types of electrical controls are available. Each is mounted and wired in a panel integral with the condenser. Base unit includes a power block for motor and line connections. Main control provides a contactor and 24 V control circuit for remote control. Fan cycling control provides for head pressure control on multiple fan units by cycling one or more fans. Refrigerant pressure or ambi- ent temperature provide the control signal. Fan speed control is a Liebert proven method for providing the finest electrical means of head pressure control. Number one fan (two on 6 and 8 fan models) modu- late in response to refrigerant pressure. The balance of fans on multi -fan units cycle on ambient control. This option only available on 1 and 2 refrigerant circuit models. (R -22 only) An optional disconnect switch, mounted in the electrical panel is available for any of the above. MAXIMUM RELIABILITY Because these condensers are fac- tory wired, piped, and tested, start -up problems are eliminated, and relia- bility of the overall system is greatly Increased. FAN SPEED WINTER CONTROL The winter control system features a variable speed motor specifically designed to be used in conjunction with the solid state fan -speed control transducer. This transducer directly senses the head pressure of the compressor and varies the speed of the fan to maintain constant con- LEE -TEMP WINTER CONTROL SYSTEM The Lee -Temp winter control system's heated receivers permit startup and positive head pressure control at ambient temperatures as low as — 30 °F. The Lee -Temp pack- 1 densing temperature and system capacity. Auxiliary fan motors are controlled by ambient thermostats. This system allows for operation at ambient temperatures as low as — 20°F when used with a low pressure cutout time delay. (Not available with Quiet -Line) age includes an insulated receiver, a pressure relief valve, three -way head pressure control valve, and roto lock valves. Mounting parts are provided for field installation. J CONDENSER MODEL PHASE 208/230 460 575 WSA FLA WSA OPD FLA WSA OPD FLA WSA OPD 15 065 1 4,8 6.0 15 2.5 3.1 15 : .,' 1.9 , ; . :24' i z 2 086 1 4.8 6.0 15 2.5 3.1 15 : 71 1.9 • 5 2.0 107C - _ 4,8 ...............1 4,8 6.0 §_,.....21 15 2.5 3,1 3.1 15 15 ':C.'1; ''' '''''',..:1.911;' , '''', 2.4 ''.. '.:;:! ' '::2.4: ':' •' ..1 15 _ 083U104L 1 30 3 8.8 10 20 4.5 5.1 15 3.3 3.8 15 20 175/2 3 8.8 10 20 4.5 5.1 15 3.3 3.8 15 4.5 6.5 165L/205L 2.8 4.2 8.8 10 • 20 4.5 5.1 15 3.3 3.8 15 4.2 4.2 258 3 12.8 14 25 6.5 7.1 15 4.7 5.2 15 5.6 291 3 l'2*}..... 14 25 6.5 7.1 15 4.7 5.2 15 15 251L/308L 3 12.8 30 25 6.5 7.1 15 4.7 5.2 15 16 36 0 3 16.8 18 30 8.5 9.1 15 6.1 6.6 , 15 35 330L/415L 3 16.8 18 3 8.5 9.1 15 6.1 8.8 15 16,5 480C 3 16.8 18 3 0 32 9.1 15 6.1 6.6 15 . 510C 3 - 16.8 18 30 8.5 1 15 6.1 6.6 15 15 616L 3 25.6 26.8 40 13 13.6 2 0 9.4 9.9 15 6 6 OL 3 33.6 34.8 45 17 17.6 0'o., 12.2 12.7 17.5 830L 3 33.6 34.8 45 17 17.6 20 --. 12"6...., 12.7 17.5 960C 3 33.8 34.8 45 17 17.6 20 12.2 -.14 124....„ 17.5 1010C 3 33.6 34.8 45 17 17.6 20 12.2 12.7 CONDENSER MODEL PHASE 4d.............-.- 208/230 460 575 FLA 4 WSA OPD FLA WSA OPD FLA WSA OPD 065 3 5 15 2 2.5 15 1.4 1.8 15 086 3 4 5 15 2 2.5 15 1.4 1.8 15 I C 3 4 5 15 2 5 2.0 15 - - 083L/104L 3 4 5 15 2 2.5 15 1.4 1.8 15 _ 0 3 8 9 20 4 4.5 15 2.8 3.2 15 175/21 3 8 9 20 4 4.5 15 2.8 3.2 15 165L/205L . 258 3 8 12 9 13 20 20 4 6 4.5 6.5 15 15 2.8 4.2 3,2 4.6 15 15 • 291 3 276 3 13 20 20 6 6 6.5 6.5 15 15 4.2 4.2 4.6 4.6 15 15 251U3 08L 3 12 360 3 16 17 30 8 85 15 5.6 6.0 15 330L/415L 3 16 17 3 8 8 5 15 5.6 6.0 15 480C 3 16 17 30 5.6 8.5 15 5.6 6,0 15 510C 3 16 17 30 8 15 15 5,6 6.0 15 616L 3 24 25 35 12 12.5 15 8.4 8.8 15 660L 3 32 33 40 16 16,5 21 11.2 11.6 15 830L 3 32 33 40 16 16,5 20 . 11.6 15 960C 3 32 33 40 16 16.5 20 11.2 - 15 1010C 3 32 33 40 16 16.5 20 11.2 CONDENSER MODEL PHASE 208/230 460 575 FLA WSA OPD FLA WSA OPD FLA WSA OPD 063 3 1.8 2.3 15 0.9 1.1 15 - - 119 3 3.6 4.1 15 1.8 2.0 15 - - - 127 3 3.6 4.1 15 1.8 2.0 15 - - - 143 3 3.6 4.1 15 1.8 2.0 15 • - • 179 3 5.4 5.9 15 2.7 2.9 15 - - - 214 3 5.4 5.9 15 2.7 2.9 15 • • - 238 3 7.2 7.7 15 3.6 3.8 15 • • - 276 3 7.2 7.7 15 3.6 3.8 15 - - - 286 3 7.2 7.7 15 3.6 3.8 15 • - - 358 3 10.8 11.3 15 5.4 5.6 15 • - 409 3 10.8 11.3 15 5.4 5.6 15 - - - 477 3 14.4 14.9 17.5 7.2 7.4 15 - - 572 3 14.4 14.9 17,5 7.2 7.4 15 - - • ELECTRICAL DAV!, Table 2 Fan Speed Control Lee-Temp or Fan Cycllng, Standard Lee-Temp or Fan Cycling, Oulet-Line Shaded area - Condenser uses a 208/230 vol motor and a stepdown transformer. • MODEL NUMBER woramow FAN QTY A B C L N OF CKTS CODS) CONNECTION SIZE NET WEIGHT LBS. MODEL NUMBER FAN QTY A B C L N OF CKTS (00S) CONNECTION SIZE NET WEIGHT LBS. HOT GAS LIQUID HOT GAS LIQUID Standard Models Qulet•Llne Modals 'C9'063 1 42 — 44 511/2 1 11/8 5/8 315 'CS'083L 1 42 — 44 51112 1 7/8 618 295 0'063 1 42 — 44 51112 2 7/8 1/2 315 CS•119 2 82 — 84 911/2 1 11/8 7/8 425 'CD1041 1 42 — 44 511/2 2 7/8 1/2 315 •CD•119 2 82 — 84 911/2 2 7/8 5/8 425 •CD•107C 1 42 — 44 511/2 2 7/8 1/2 335 'CS•127 2 82 — 84 911/2 1 11/8 7/8 495 •CD•130 2 82 — 84 911/2 2 7/8 5/8 425 'CD•127 2 82 — 84 911/2 2 11/8 7/8 495 'CD•185L 2 82 — 84 911/2 2 7/8 5/8 425 'CS143 2 82 — 84 911/2 1 11/8 7/8 515 •CD175 . 2 82 — 84 911/2 2 7/8 5/8 495 •C13143 2 82 — 84 911/2 2 11/8 7/8 515 •CO 2 82 — 84 91112 2 11/8 7/8 485 •CS'179 3 122 — 124 1311/2 1 11/8 7/8 500 •CD'217C 2 82 — 84 911/2 2 11 /8 7/8 515 •CD•179 3 122 — 124 1311/2 2 11/8 7/8 500 *CO 3 122 — 124 1311/2 2 11/8 7/8 500 'CS'214 3 122 — 124 1311/2 1 1 518 11/8 840 'CD•258 3 122 — 124 1311/2 2 11 /8 7/8 870 'C0•214 3 122 — 124 1311/2 2 11/8 7/8 840 *C0'3081. 3 122 — 124 1311/2 2 13/8 11/8 670 •x•238 4 82 80 184 1711/2 1 15/8 11/8 740 •CD•291 3 122 — 124 1311/2 2 13/8 11/8 780 •CD'238 4 82 80 184 1711/2 2 13/8 11/8 740 •CD•330L 4 82 80 164 1711/2 2 13/8 11/8 741 'CS'278 4 82 80 184 1711/2 1 21/8 13/8 1025 •CD'415L 4 82 80 184 1711/2 2 13/8 11 /8 816 •CD•278 4 82 80 184 1711/2 2 15/8 1 118 1026 'C0'360 4 82 BO 184 1711/2 2 13/8 11/8 815 •C9•288 4 82 80 184 1711/2 1 21/8 11/8 1105 •CD•460C 4 82 80 164 1711/2 2 15/8 11/8 1025 •00'288 4 82 80 164 1711/2 2 11/8 7/8 1105 •CD•510C 4 82 80 184 1711/2 2 15/8 1 1/8 1188 ' CS'356 8 122 — 124 1311/2 1 13/0• 7 /8' 1260 'C'C •CD 680L I - I Dl x 122 — 124 1311/2 N I N N 15/8 1 1/8 1380 'CD•358 mmIm 122 — 124 1311/2 N NICV 11/8 7/8 1280 82 80 184 171 1/2 1 5/8 1 1/0 1600 'C0•409 •CD'477 122 — 124 131 1/2 1 5/8 1 1/8 1380 'CD'830L 82 80 184 1711/2 15/8 11/8 1750 82 80 184 171 112 15/8 11/8 1800 •CD•9800 I{fui 82 80 184 1711/2 NN 21/8 13/8 2090 •CD•572 8 82 80 184 1711/2 2 21/8 11/8 2430 'CD'1010C 82 80 184 171 1/2 2 1/8 1 5/8 2840 *IDS size al manifold Interconnection. Lisbert applied & field Installed. 6 DIMENSIONAL C - TA EYE BOLTS FOR LIFTING CONDENSER Figure 1 PROVIDED ON 4.8 8 8 FAN MODELS ONLY TYPICAL FOOTPRINT Table 3 Condenser Physical Data � --1 e44i• (1533mm1 19 " (457mm) OUTLET /INLET CONNECTION 43V3. C (1097mm) Figure 2 OUTLETIMLET CONNECTIONS 1 / (12.7mm) DIAMETER ANCHOR BOLTS (TYP.) 1. 881/4. (2203mm) UNIT ANCHOR PLAN c 431'n' (1107mm) 84W (1533mm) 37Vi' (982mm) HEIGHT TO TOP OF FAN GUARD 434' (109Smm) C CENTER LEG PROVIDED ON 4 8 8 FAN MODELS ONLY FOR LEE•TEMP RECEIVERS: 4 LEGS FURNISHED FOR 1 FAN MODEL e LEGS FURNISHED FOR 2 8 3 FAN MODELS IS LEGS FURNISHED FOR 4 FAN MODELS (ADDITIONAL LEGS INDICATED WITH DOTTED LINES) 87W (2213mm) HEIGHT TO TOP OF FAN GUARD 43 Vi" (109Smm) 37 h' (9821 A CLEARANCE OF 35 IN. 914.4mm) IS RECOMMENDED ON ALL 51DE5 FOR PROPER OPERATION AND COMPONENT ACCESS. • MODEL CAPACITY TONS R -22 CONNECTIONS SIZES (ODS) RECEIVER NET WEIGHT (LBS.) HOT GAS FROM CONDENSER LIQUID LINE OPERATING CHARGE LBS. R -22 PUMP DOWN CAPACITY LBS. R -22 HEATER WATTS 110 OR 230V W40 14,5 11/8 7/8 5/8 3.0 30.0 150 80 W50 14.5 13/8 7/8 7/8 5.5 55.5 150 105 W60 14.5 13/8 7/8 7/8 8.3 83.7 150 125 W410 14,5 1 3/8 7/8 7/8 10.0 114.0 150 140 W1200 14.5 1 3/8 1 1/8 7/8 16.6 167.4 2 (0150 290 063 36 119 47 127 71 143 118 179 70 214 175 238 93 276 186 286 233 358 140 409 280 477 186 572 465 8 Lee -Temp Specifications (Opt �1) Lee -Temp Regulator has fixed setting for 210 PSIG Head Pressure. LEE TEMP INSTALLATION /REFRIGERANT CONNECTIONS Total Condenser Refrigerant Volume Based On ODF Liquid Temperature MODEL NUMBER Standard Models 065/083L 086/104L 107C 130/165L 175/205L 217C 251L 258/308L 291 330L 360/415L 4800 510C 616L 660L 830L 960C 1010C Oulet -Line Models LBS. OF R -22 24 36 48 47 71 51 70 105 140 93 140 186 279 210 186 279 372 555 The Lee -Temp package is factory pre -piped and only connecting pip- ing to the condenser needs to be field installed. The package attaches to the two legs of the condenser. Field supplied inverted traps are to be mounted as shown. Avoid soft solders such as 50/50 or 95/5. Use a high temperature solder with a SECURE EACH LEG TO CONDENSER FRAME AT ALL POINTS SHOWN USING HARDWARE PROVIDED •HOT GAS AND LIOUID LINE ORIENTATIONS VAR FROMT IHSCONFIGURATION. MAY • LIOUIO LEVEL - SIGHT GLASSES ROTO LOCK VALVE COMBINATION HEAD PRESSURE CONTROL I CHECK VALVE • Allti1/4174111/ 4111/4111 AEI .111/4111/51111I4111,411/411011/ C ; r ' ' �•' LEE•TEMP WINTER SYSTEM AIR COOLED HEATER CONDENSER PADS DEHYDRATOR LIHAND SHUT OFF DISCHARGE UNE MUFFLER 14111 RAC OPTIONAL HOT GAS BYPASS SOLENOID VALVE minimum temperature of 1350 °F such as SILFOS, Use a flow of dry nitrogen through the piping to pre- vent the formation of copper oxide scale inside the piping. Refrigerant lines and traps should not interfere with the electric panel door or elec- tric code restrictions. LIOUID LINE LIQUID LINE (CIRCUIT 1) (CIRCUIT 2) HOT GAB LINE (CIRCUIT 1) CHECK VALVE PRESSURE REUEF VALVE SOLENOID VALVE EXPANSION VALVE EXTERNAL EOUALIZER LEE TEMP (Optional) ;' CO DENSER CONTROL L 1 VALVE. 4 • • • • • • ••4 0 ;.: -- t' BIGHT GLASS _ L EVAPORATOR � / ='• it SENSING BULB J 1 • OPTIONAL HOT -_ // / • , • OAS OY•PASS VALVE SERVICE VALVE SUCTION UNE COMPRESSOR INVERTED TRAPS BY OTHERS HOT OAS LINE (CIRCUIT 2) ELECTRIC SERVICE SUPPLY BY OTHERS ROOF • • • COMPONENT Af EMSLY/INSTALLATI( N LEG ASSEMBLY • The legs are shipped loose and are to be field mounted as shown with the hardware provided. RIGGING Holes are provided in the condenser legs for lifting the condenser. Spreader bars are required. A typical rigging is shown. 4, 6 & 8 fan units . also have lifting lugs.' HIGH VOLTAGE ELECTRICAL CONNECTIONS (fig. A) Line Voltage is connected to the terminal strip or directly to the fac- tory supplied locking disconnect (optional). Check voltage and com- pare to nameplate. LOW VOLTAGE ELECTRICAL CONNECTIONS (fig. 8) A control interlock between the condenser and compressor unit is provided on all but base priced condensers. 24 Volt Wiring should be in accord with local codes. Fig. A Fig. 8 FAN SPEED CONTROL — REFRIGERANT CONNECTIONS Avoid soft solders such as 50/50 or 95/5. Use a high temperature solder with a minimum temperature of 1350 °F such as SILFOS. Use a flow SECURE EACH LEO TO CONDENSER FRAME AT ALL POINTS SHOWN USING HARDWARE PROVIDED AUXILIARY FAN SETTINGS The auxiliary fans are controlled by ambient temperature. The ther- mostats should be set approximately as follows, individual installations may require settings other than listed. zz Pct Qui �C) No.2 (& No.4) 60 °F 60 °F 55 °F Two Fan Models Three Fan Models Four Fan Models No.3 30 °F 30 °F FAN SPEED CONTROL FACTORY MOUNTED SCHRAEDER VALVE DEHYDRATOR HAND SHUT OFF VALVE SIGHT GLASS - PRESSURE RELIEF VALVE (BY OTHERS) DISCHARGE LINE - MUFFLER OPTIONAL HOT GAS BYPASS SOLENOID VALVE of dry nitrogen through the piping to prevent the formation of copper oxide scale inside the piping. LIQUID (CIRCUIT 1 ) E HOT OAS UNE (CIRCUIT 1) FAN SPEED CONTROL FAN 1 CAPILLARY TU B E MROLLEfl ll CONDENSER CONTROL AIR COOLED ROOF CONDENSER SOLENOID VALVE EXPANSION VALVE EXTERNALEOUAUEER 4:4-14,16.•• -4 • •i . • .w .S.11 EVAPORATOR SENSING BULB OPTIONAL HOT ,. .- , GAS BY•PASS VALVE l • SERVICE VALVE L.- SUCTION UNE COMPRESSOR INVERTED TRAPS BY OTHERS --HOT GAB UNE (CIRCUIT 2) LIOUID LINE )CIRCUIT 2) ELECTRICAL SERVICE SUPPLIED BY OTHERS 'HOT GAS AND LIQUID LINE ORIENTATIONS SHOWN ARE TYPICAL. SOME MODELS MAY VARY FROM THIS CONFIGURATION. NOTE: INVERTED TRAPS TO CLEAR DOOR SWING 10 1I I EARTH GROUND BY OTHERS 2d V. 2 WIRE CONDUCTOR FIELD SUPPLIED. (SEE NOTE 2) 7 PHASE LINE VOLTAGE SUPPLY BY OTHERS 1 707 - 11H OROUIID BY OTHERS SEE NOTE 5 Fri THIS AREA ONLY, PROVIDED AND WIRED AS SHOWN ON I FAN MODELS. THIS AREA ONLY, PROVIDED AND. WIRED AS SHOWN ON 2 FAN MODELS. THIS AREA ONLY, PROVIDED AND WIRED AS SHOWN ON 3 FAN MODELS. COMPLETE DIAGRAM — PROVIDED AND WIRED ON 4 FAN MODELS To OPTIONAL DISCONNECT SEE SWITCH NOTE 5 ( SEE NOTE 3) F52 A FST PROVIDED ON 575 V. MODELS ONLY. FAN SPEED MOTOR "PS" AUX. MOTOR A.3 T T T ICFI 2Crl 3CF1 T ICES AUX. MOTOR AJ, Typical Wiring -J 4 Fan Units with Fan Speed Control r —• A T L _. L1 L2 �— L Typical Wiring - 2 to 4 Fan Units with Fan Cycling Control (FCC) Option 11 TI 70 AIR COOLED CONDENSER 24 V 2 WIRE I I OPTIONAL DISCONNECT CONDUCTOR FIELD SWITCH I I SUPPLIEO (SEE NOTE 2). — 'SEE NOTE 3) 1 .L.II 3 PHASE LINE "1-1' BY SUPPLY 1. 3 BY OTHERS L BR BR BR s 3.2 A. CIRCUIT BREAKER PROVIDED 6 WIRED ON 2 FAN MODELS PROVIDED S WIRED ON 3 5 4 FAN MODELS OR BR 8R SEE "GPO" IN T T T I 'T T — r TABLE BELOW ICFI 2C 13 F1 ICF2 2CF2 3CF2 it OR OR OR II 1 BR BA I FAN I MOTOR I M2 II i AIR COOLED /CONDENSER NOTES: • 1. ALL MOTORS HAVE INTERNAL OVERLOAD PROTECTORS. 2. ) CONTROL VOLTAGE WIRINi FROM ROOM UNIT MUST BE MIN. OF 16 GA. (1.665 mm ) FOR UP TO 75 FT. (22.9 m) OR NOT TO EXCEED 1 VOLT DROP IN CONTROL LINE. 3.) OPTIONAL DISCONNECT SWITCH FACTORY SUPPLIED IN CONDENSER ELECTRIC BOX WHEN ORDERED. REMOTE DISCONNECT SWITCH (WITHIN SIGHT OF CONDENSER) TO BE SUPPLIED AND MOUNTED BY OTHERS WHEN NOT ORDERED WITH CONDENSER. WIRE PER LOCAL CODES, 4.) THREE —PHASE MOTORS PROTECTED FOR PRIMARY SINGLE PHASING CONDITIONS. TIII SEE NOTE 7 T1 SEE NOTE S 85 "F /CCDF) Option R R 1 ICF32F CF3 CONDENSER " CONTROL BOX 5.) CONTROL VOLTAGE TRANSFORMER PRIMARY TAP IS DEPENDENT ON LINE VOLTAGE. SEE LABEL ON TRANSFORMER FOR DETAILS. 6.) THIS SCHEMATIC APPLIES FOR CSF AND CDF MODEL CONDENSERS ONLY. 7.) AUXILLARY FAN MOTOR A-3 IS PROVIDED ON FOUR FAN MODELS ONLY. 8.) CSF MODELS HAVE 1 PRESSURE TRANSDUCER. CDF MODELS HAVE 2 PRESSURE TRANSDUCERS. 9,) VAR NOT SUPPLIED ON 460V MODELS. • 410 CONDENSER PIPING CONNECTION ENTERING HOT GAS LINE IN. (mm) SIZES CU. OD. FRETURNING LIQUID LINE IN. (mm CONDENSER MODE!„ NUMBER CSF -185 7/8 22,2 1/2 (18.7) 112 (12. 519 1/2 (12.7) tr2 (12.7) 518 ,. 1/2 12.7) so (152) 100 •.5) 150 / 100 16 5 ) t 150 4.7 50 (102) 100 (30.6) 1. , 45. 50 (30.5) (152) 150 ( J� 1/2 12.7) 112 (12.7) 318 (152) 51 . . 7R ( (2$.2) 7i r : 7/6 (222) 7/9 - 7/5 ._. 112 12.7) � (1 1/2 (12.7) sA am 74 7 = 039.083 7/0 (22.2 50 (15.2) 100 (30,5) 150 48.1 50 (15.2) 100 (59,8) 100 (50.1) 1 .: 15. 5/0 15.9) C .,R 1/2(12.7) 10 (152) 100 (30.5) 1' 417 05.2) 100 (305) 150 5. 1116 (29.6) 1115 r .. 11A U.: 1 CSF-088 7/8 (22.2) 50 (152) 100(30,6) 1 • . 45. CORMS 7/8 22.2) UPI8T5M80A ((322) 100 (504 1 45. C5F41971181C 1 1/8 (28.= U(230A/736 , 5/8 (15.0 CDF/o47 070 7/8 22.2) UN3758h745 UP4/5111745 .. 50 (15.2) too . • .55) 1510 45. 80 (15) 100 (70.6) 150 (48.7) C8F -1044. 1 1/8 (28.8) : r, . , r 7A 1112) 7A 1 1A 1112) in (15.9 C01 7/8 (22.2) 1/2 12.7) CSF -130 1 1/8 (28.5 7/8 (22.2 057-170 7/8 (22.2) 5/8 15.0) 2.*F -1651 1 1/8 48.5 718 (22.2) Cl/F-1651. 7/8 (22.2) 5/8 (19.9) C5F -179 1 7/8 (28111 7/8 22.2) CUF175 C5F /C0F206L 7/8 (22.2 11/1 25.5) 6/8115.9) 7/0 22.2) C2FA1 1F- 2170/2180 11/8 28.6) 7/8 22.2 7/8 22.2) CCF /0118451L 1 1/0 28.8 CS1/121F -255 1 1/8 (20.51 7/4(22.2 08F/C01 1 3/8104.9) 1 1/8 (28,5) 05F301 L 1 5/8 41.3) _ 1 1/5 (26.5) CDF-3 U1. 1 3/8 34.9 1 1/8 (23.5 C6F4ISL 1 5/8 41.3) 1 1/8 (25.6 C0F -3330L 1 3/8 34.9) 1 1/8 28.5 CSF7CVF3SD*3492 1 3/8 (34.9) tLAE)l•111111 CSt41S1. 2 1/8 54.0) CDF 4154. 001 1 3/8 (34,9 2 1/5 54.0) 1 5/8 41.3 1 1/8 (20.5 1 3/8 .9 Car-51 n 2 1/0 (54.0) 1 3/5 34.0) CDF410C 1 5/8 (41.3) � - 1 1/8 (28,5) R OMMENDED UNIT M L MB R 63A118IA + A 58 5115m -7SA REFRIGERANT 'tom T . m 50 (15.2) 100 30.5) 1." 45. 50 (132) 100 J 1 45. 50 (152) 100 (90.5) 150 48. AllimiW LINE SIZES HOT E s IN. mm) CU. OD. uLINE IN1mmL 5A (18.9 7/8 • 718 - 7/5 (M.2) TM 022) 718 518 (18.9) 7I8 c22.2J 7/b t 1/2 (18.7) 112 (12. 519 1/2 (12.7) tr2 (12.7) 518 ,. NIA14114A/118A * $1425AM30A_ so (152) 100 •.5) 150 / 100 16 5 ) t 150 4.7 50 (102) 100 (30.6) 1. , 45. 50 (30.5) (152) 150 ( J� 74 (22.2) 7/8 (22.2) 7/3 r_ 14 128.8) 11.• t. 1 1/4(7211�4) 1 116 (28.6) Ilia _ ., 914 10.1 314 18.1) 112 (12.7) 318 (152) 51 . . 7R ( (2$.2) 7i r : 7/6 (222) 7/9 - 7/5 ._. 112 12.7) � (1 1/2 (12.7) sA am 74 7 = 111411-1533 fl*1 ,14SA 1 _ . 1915/1M14AU/118AU F(UA1415AIVI70AU 50 (15.2) 100 (30,5) 150 48.1 50 (15.2) 100 (59,8) 100 (50.1) 1 .: 15. 3/4 (14.1) 712 r, 7 t_..1 r• 1 14 ( 0/2.2) 2#e) 1 1/9 29:1 I5b111Fil18AU PINE-3553U 81tlUf1dlOAU 14Y(511110A 10 (152) 100 (30.5) 1' 417 05.2) 100 (305) 150 5. 1116 (29.6) 1115 r .. 11A U.: 1 7A 7/8 7i _, 7/5 224} 11 r_ UFf21A2120A 50 (152) 100(30,6) 1 • . 45. 718 (72.2) 7/5 (122) 7/8 + 1*2 (12.7) SA 05. UPI8T5M80A ((322) 100 (504 1 45. 1 115 F 1 L_4 U(230A/736 , 50 (152) 100 e.'.5 150 45. 1 115 (284 1 1h (28 11/8 OA 7/8 122.2) 713 7A r4 UN3758h745 UP4/5111745 .. 50 (15.2) too . • .55) 1510 45. 80 (15) 100 (70.6) 150 (48.7) �• 1 118 (25.5) 1 74 (342 1 114 (34.8) : r, . , r 7A 1112) 7A 1 1A 1112) 12/02/99 11:23 FAX 2067636( RETURNING LIQUID UN& GYP.) ENTERING NOT GAS LINE (IYR) INVERTED TRAPS AAC 8E FIELD SUPPLIED AND INSTALLED 1TYP.) WNGN INSTALLING TRAPS, GLEARANOE MUST 158 PROVIDED FOR SWING OF . END ACOE88 DOOR. TRAPS TO DGENO ABOVE SASE OF COIL HY A MINIMUM OF 7 1/2' (190mm). JOHN DONOVAN- CAMPBELL PIPING: FAN SPEED CONTROL CONDENSERS ( 3002 Poo 11UN5 LoNO911 THAN 150 Ft (46.74.4) !EQUIV. LENGTH CONSULT PACT f%Y r mares LINE BRING. 12/02/99 11:23 FAX 2087838700 JOHN DONOVAN- CAMPBELL CO TYPICAL GENERAL. ARRANGEMENT DIAGRAM AIR COOLED MODELS SL -11897 PG 5 ti Check Valve Hot Gas.'" (Shipped Loose for Discharge Field Installation) Schrader Valve Condenser Coil ti y! Fusible Plug J� Inverted Tnspa *on discharge and return fines to extend .../"-- above base of colt by a / .� minimum of 7112' (190mm) f I if 11 11 Traps every I 11 25 ft. (7.6m) ' I 11 of rise (r » 11 Hot Gas �.. " By -Pass 11 Valve Expansion Valve Liquid Return Solenoid (� Valves Shut•Ofr� Sight Valve Glass Evaporator Coil _,, Sensing �� - �-�.`\ Bulb --gt iii Scroll Compressor External Equalizers SINGLE CIRCUIT SHOWN FACTORY PIPING FIELD PIPING *Components we not supplied by Uebert but ere recommended for proper circuit operation and maintenance, REV 9199 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M99 -0243 PROJECT NAME: PRIME SOURCE CORP XX Original Plan Submittal Response to Correction Letter .# _ Revision # After Permit Is Issued DEPARTMENTS: Build' ngDivision v orks q ublic Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Ci 1 / '21 Structural Incomplete n Comments: TUES /THURS ROUJING: Please Route uJ Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 1 - 4-2000 Approved n Approved with Conditions ` Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions \PRROUTE.DOC 5/99 Response to Incomplete Letter # DATE: 12 -3 -99 Planning Division Permit Coordinator DUE DATE: 12 -7 -99 Not Applicable n No further Review Required n Not Approved (attach comments) U REVIEWER'S INITIALS: DATE: Dear Sir: City of Tukwila Fire Department Fire Department Review Control #M99 -0243 (510) Re: Prime Source - 355 Treck Drive December 10, 1999 Thomas P. Keefe, Fire Chief The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildin9's shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been John W. Rants, Mayor n. _.._ _ • • • • — 110100 — es........ /911A1 C'C_AAAA - Cev. MAIO C7C.AA40 Page number 2 obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, City of Tukwila cc: TFD file ncd Fire Department The Tukwila Fire Prevention Bureau John W. Rants, Mayor Thomas P. Keefe, Fine Chief LJo�dmiartvrc CthNnn. AAA Anilnvvr Dart. Pact • T,,Lwllo Wfjchlnetnn I12111A • Dhnnn. MA) C7C.AAfA . row /9/1A) C7C.AA20 15452 -000 (8/971 . ( 05-7,veg. Detach And Display Certificate DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CC01 . :MACDOM *248J9'08/ EFFECTIVE DATE • - , 04/29/1976 MACDONALD MILLER CO 7717 DETROIT AVE SW. SEATTLE WA 98106 Detach And Display Certificate 014i f/a,:-e; ce (4-z .7A C14 icortze • t. ROOFTOP PACKAGE 7 GAS/ELECTRIC SCHEDULE UNIT AREA LUXNRE Total SENS. I HEAT HEAT EER SEER CFM ESP FAN 800 500 ggEE ELECTRICAL WT NOTES N0- SEWED MOM COOL COOL INPUT OUTPUT HP Volt/ph MCA LBS AC 182, 1DCUC- W09DN185•(1.5 TON) UMW 83 MBH 163 MBH 130 MBH 8.9 -- 3000 or 3 460/3ph 21.9 1167 1,2,14,5,6 AC 38 4 1DHUC W66064115 - (5 TON! MASH 54MBH 108MBH 79MBH 9.4 -- 1950 0.5' 1.5 46013ph 16.7 720 1,3,4,5,6 NOTES: ". 1. UNIT PROVIDED BY CUSTOMER. 2. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECTS. 3. FLA = REHEAT, HUMIDIFIER, AND FAN MOTOR COMBINED. 4. FIELD TO ROUTE 3/4' CONDENSATE DRAIN ABOVE T -BAR CEILING TO SNACK AREA SINK (BELOW COUNTER TOP) 5. 114" O.D. COPPER COLD WATER REQUIRED FOR INFRARED I 'UMIDIFIER. FIELD TO TAP INTO SNACK AREA SINK COLD WATER LINE 6. ACCESSORIES: A) CONDENSATE PUMP WITH INTEGRAL CHECK VALVE. FIELD TO VERIFY REQUIRFMENTS- 7. NO STRUCURAL REVIEW REQUIRED SINCE ROOF TOP UNIT C 400 POUNDS- USE 4X4 6 FOOT SLEEPERS TO SPAN STRINGERS. 8. NO STRUCURAL REVIEW REQUIRED SINCE SLAB ON GRADE_ _TRECK DRIVE EE15T, NG GAT NEW_LZ GAS PROVIDE_ TEE._ INTO $IF14.O.//EA. 3 PLU 4lII 2 15A4i ,UP SITE PLAN ..SCALE: J" = Z71 --' EXISTING GAS NW ,2.1. 6E3 _)LL_._ SIZES 5WWW. A RE. NE"T_- .INSI :af.. 17 INENSIONS GENERAL NOTES ALL DUCT WORK CONNECTING TO EXISTIW4_ DUCTS TO BE SN METAL. ALL NEW DUCT SYSTEMS TO BE DUCT BOARD_ EXCEPT THE VERTICAL RISE TO EQUIPMENT VJ HI C.14 f 5 S. - - METAL WITH I" LINING. � REMOVE EXISTING Gr.AS MET E. 12 (BV WNG CO. 34Ew a 2 ." 45 S C N J6GT TO L$ - rIXG 4 41 - ,{.VFRLFY S.1 LE) _ - -. .(nAS MET 6R. B Y._ V41.4.4 C Q: -- ASH) WAREHOVSE A DD:ItION L 0 DIFFUSER LIST "Cu Eli 1 J4 l'FF Its E R_._ 444EMZ5 ILMD -FP, LAY JN T -BAR, 24 - % Z4` - - -. - -_ GRID. E.C. ECG CRATE: PLASTIC GRID .._ TW6 T9P WALL GLiLLE. AMEMOSTAT" 53 HD ABBREVIATION LIST DUCT BOARD S_m.- - SHEET METAL 5. L. SOUN L3 LTILTiWA . 1' 1. NJ LIZ 64 MELT SIZE -- - 514PPLY. AIR - DIRECTION- ,TETULA OR .EXiIJEUS, AIA - s 'r s VOLUME DAMPER SeRRAI FLEX MKT FTRE pm...TPER- vERTIZ - 1 SE PE f'71, THERMOSTAT main THERMa5TAT c - -s•GAS PIPE. ATEIDME tirlI I4 FLIN3_R- NOTES: 1. ELECTRICAL. POWER WIRING & DISCONNECTS BY 3THERS 2 WITH SMOKE DETECTOR. 3. CONTROLLED BY NEW HONEYWELL M1 T7300 PROGRAMMABLE T -STAT 4. ALL ROOFTOP DUCT OPENINGS TO HAVE BIRD SCREENS 5. WT1H OU'TMMOE AIR ECONOMIZERS T1A4 E. INSTALL NEW EQUIP PER STATE AND LOCAL CODES a IC II VO NAL G C LiN AkITV 3T�31�i5 'ZOO ^ C. 14 A T I ` STRANDER ISLV O. c la•I EAgI N qc - C�L 1 4 3 VICINITY MAP EQUIPMENT SCHEDULE O $ " E 5 A EVAP FAN: / HP DIRG.CT DRIVE, EL>:tTRl HEAT 7 •F KW 9.L FLA, 460 V/30, WITH LOW j Nom" KT UNIT OPERATING WEIDNT 45.1 LBS. ROOFTOP AIR .GONQ ITIONER: TRA.NE 3AC 304 NOMINAL COOLINCa CRPAGITV S TO N S , LOGO CF-, AT O.6" ES. P., EVAP FAN % I•' H•P•, BELT DRIVE II40 R I.6 QHP, IS•H FL A,. 450V)14', WITH THROW AWAY - - FILTERS, ROOF GURU, >£CCNOMILER , RELIEF DAM PEE 1 UNIT OPERATING WEI 144 L65' -�J ,F- XIS?'I.MG UIJ1T HE.ATISR. "RE.Zh4O1L" XL ZSO, Z6S0 CFM,. FAN 4 H• , Ge HEAT: LSO M 45 INPUT, TLS'V // , car.' 1 - r ZGI 1- C3. J OPr= R A' - rENG WE141.4T ,° 4Tf _ GQJL.: "B RA so H" SLIP -JN ISx 1e.. _ 7 CFM, '8 0 KW 500 FPM, MINIMUtv1 240 FPk - 33.7 TE R13E, L STEP COIL , 2.4V COhd?' , 460\//344A. UG7 MI CTRIG, DUCT co "9RASCH" SLIP - IN, 8tx 1a, Iarra M, 2 14W, 57G FPM, MINIMUM 47I FPM, 5.° TEM R'ISE L STEP COIL , 24 d CoNITRFL, 480V/14< l: f f".1 g FAN % ' JEANN AIR ". EAI PSG .R r' , o F MoEBT 311 CP T Ye" S. P., BELT 0AM /aa E FL V4 H,P._. - MOTOR, 11,5V /' I4 , , CONS TANT OPERATION • , Z,0 1 L` $Ac-ICDR.%FT DAMPER , E.X PLO SI0 4 PRC`OI , UN .._. OPERATI1 WEI6KT '174 i_ BS. SEPARATE p ER - REQ .: 0 M 0 PLUMS° CAS P1F "rTG CITY OF T1.11-01V1LR BUILDING OtVt510N Z.1- ANAT ., .(. N Al , D R T , iiR r s2T 2 � H.F. IV II /10, ©N-GFP w /WJ11.L Ei�u.F UNIT OPERATING WEIGHT JS L$ a "S1tM14 AIR" CICR 1LDDF NOUWTED L 6 GFM 4' S. R1 cup PRII , fL1E'O MLIPM, *Ap K P MOTO_.R, I ISV! /l. /., ON-OFF W/Z SPSCD. WALL SWIT+Lff 1 4 OPERATIN WENS NT 30 LBS. 1 &R "RE3MLAIR" RR - IS , ROOF MOt1NT ($ REOj 912 L: F3 AT O' STACK HT, S MPM WIND, LD'4T. 7Lf ' C;Y`: s 311 ` °. "' "�. n , ate a 1 vl? K D l 1 J, C 3JC „)c '1 ' :3 npm , SIP'` T 0 ,','Y tines IE :ut;• . ,,,Cel,• Con - ,10 COP o i ' a4Qr i �.l r a .no�vted9e By / Date 119% (5.) Permit No PE GET,ED.,' 0:'r OF pEAM 1199-D;q ISSUED 9/22/77 F C D N I S T R U C T I O N SHEET NO. uT V 0 0 (_ cr LiJ F- ry r r 3 o ✓ E • W V J " - J 2 L O V V O z J Q Z 0 0 0 I 1 OF 4 DWG C-0414- NO. 1 5700 ce xi oa UST ATE 12 /03 / 99 REVISED 0 PHONE (208) 783-8400 vENT CAP SHOULD EXTEND 2 FEET m AEDvE THE POINT NHERE PAS,ES THRU ROOF AND TT.E51 2 cEET HIGHER THAN ANY THE BuiLDING wiTHIN t0=0" - I I FLA M M A B LE. 5 AREA 'DO DOOM EN, , F il E - 1 SEAL— TH SCREWS PER JOINT- CLASS B FLUE INSTALLATION DETAIL IT RE . s L „ LI E E ROOF OPENING FLUE SIZE+3 CURB szEil " FLUE SIZE STORM COLLAR ROOF FLASHING _ R miNiMUM 4X4 CANT ao, ao D TERMINATE r-0" ABOVE FLOO R. WiTH BIRD SCREEN o 5.) VENT CAP RUM OUTSDE APT INPUKE CLASS B ROUND PIPE. MAX SIZE C4G U.L.RADNG OF I" TO COmBUSTIBLES GALV PIPE RELCI_LATE.Er. , -_EX.IST I KG JUilp4 SEAL-1 KREw OR LAG TO CURS 4X.1 CAN FAN BASE SIZE O O. CURB SIZE FAN BASE -1 1 BACKDRAFT i DAMPER SIZE 1 COMPRESS SOUNDLINING 1/2" TO rr, Epp ROOF OPENING BIDD +I V2" DUCT SIZE ADD -r -RoOFING PAPER UP AND OVER CURB "- SCREW OR NAIL BDD TO ROOF .-1SOUNDLINiNG ON DROP ONLY NOTE EXACT BDD AND CURB SIZE MUST BE CHECKED FROM EQUIPMENT SUBMITTALS. FINAL RESPONSIBILITY FOR CORRECT ADD AND CURB SIZE WILL BE INSTALLER'S EXHAUST FAN INSTALLATION DETAIL I NO 1 WARE HOU 3.6 2X8 MINIMUM 1 11 11C1171ax, Evv ,. L astcraFhe I , I 1 1 , I I 1 di EIRT ZCd - KEINE — -7 - WK.. ST SM.! IC NEW I - kW = r FlEiVerr gritire Ammo. r El NEW + / 10 - 3;SLICro.11161 - 3.3 RTEW extz tz r ' - r utoArizefF e T , OL T E. - _714Ewr z.43‘1, N11-- -=_TFAEW -24x/2. SM LL TR 36,2, UP MECHANICAL ' NEW Ex c‘ 'it ::\f ooF 1 1 ' 1 lus ' 1 ' II ' 11 1 1 1 --4— NEW' 3" FFCCM___CAAS EXtS 2,4.011..094G; Imersx_. GROUND FLOOR PLAN SCA LE S %a". _ prim. WO 11 T E1 5 r il Lz4,6 - IY EXlsrI4 LJ E —di Tr_ 4—• cD exaN 2-4.0 CM GO 8 N13, ki 2.30 CFI.; 1 =I I ' '1 , , 1, 1 7-g" FLUE 1:11110 G t I th•FAG j -commiol LOU SN1 Al- 0 FUME 1400C. W AfBkfO USE ^DOI, ION A' - rm RooP' COA1STR)Cfl HEM-21 4 ,1/ENT SIZEA ROOF FLASHING FLASHING SIZE I ROOFING PAPER UP VENT SIZE .6 AND OVER CURB 1 2X8 MINIMUM '1 ---4X4 CANT ROOF CURB GIZE EVENT SIZE 5" GRAVITY VENTILATOR DETAIL ,11„ SCALE T'f - NI; . c— v io n simminmsommionsimmok 00- L, CC 0 0 tj 0 CC Oi z 0 LLJ 2 ci () o at- ,/ ° .32 0 0 - 1— z 5 gz 0- w 0 (J) J L...0 CC 3 la.3; > al- LAsT DATE 12 /03 9 REvisED DWG C 0 414. 1 9 SHEET NO 1141 PI GI 20F4 - g W t_MHI . . - ‘• , KEW I:4f OAS- ON TH ROOF' 4- MIS t 8"4 FLAB- .• 430 l SUED 9/Z 2077 F or R C- C3 N GRAVITY VENTILATOR ucursorm 2 0 0 5 SDPP. L4 mop 36 I IZ SV PPLY LN 48 A 30 .BACK - DRAFT DAMPER - - RELIEF O PENT NEC\ —� Inc =1 RDaF. CURB 36><!L MOTORIZED DAM OVTSWE AIR INTAKE a4x I Z SU PPL`T D '3 OUTS 1 DE AI IALTJ3KE REM NMI NNE Is x�Nl 427 o I!I f'I NEW 26x6 MEW z _ _ 1 T3_ -01 lEx T5r - - 24. 24 EE•- � Z4, >< 1 23 -'•- Etli3? *lo za� _u00623 = 07F — F aC. ERSS'r 2X1.1 T 1 =A i d• i CD 1317 RFIDZ FJ: 15.I _ 1IIYtl. L .TsX TiT'y3s'�7 ✓. 1�1 11■ • 1'I^ FL EKTT3LE CON14 Ec IoN MOTO RI'L 0A RETURN RA % // a �R E:ttEF RURLINT- 3EA SECTION S cACE _ __ FLEXIBLE Co NN E._"`r ION ji \ S 3 AC- 5 D INSIA' CODES r Ilk' A MI Elm 1 11 / / 4 amstrffA /z "_z,1CS E -4 4: Ca R - 0 - I:I - 36 A 1Z RE - A. BOVE 36 X12 S U PPLY -BELOW 2 MOTORIZED DA M PEP. 24,12. RETURN ABovE 2.4x I Z. 5 1J PPLY 13ELO W min ww /SAC I $ AC 2 DETAIL SCALE %4 "= I -_ �L EN UNA OUTSIDE AIR IN-TA it_E / BALK DAA FT DAMPER UPP _LY .. DN A:ASTTNG 3 NAFT INSTALLATION N'OCE_S. S A E M EZMAtJI M E re* 16 UP Ter 7kC I) REM0IL FAIST,41 GAS FIRED AIR CONDIT }K{ I EW IN - AND WEIOIT R1CI' E..STINV OAS PIPLNU AND 1M {'WORK INSI AiLRh15 CURBS. FEEL) DI:TAR. AS REQUIRI:'J ;o CC :NNW . O EXISTINO DUCTWORK. 2) NEW CONTROLS S AND CONTROL VaRIN( BY NIM'- 3) POWER WTRINO AND DISCONNECTS BY OTHERS 41 INSTALL NEW EQUIPMENT PER STATE AND LOCK :1 6 ; 1 666 SMALL M -.M FILTER E3o1C CM TZ- s_rZ - R .. 11 4.ZD C -� I�EOF1Z7:f Cj LQ_00 -0 N _400 L.FM -saw_ lliic.8 -3� a II ctiaiwz 7 !]LOnlOL . t. © tXIS_ I 24x10 E 40- G' •C- c lr L_ .cElif_.. F- ESci5�1. tT1.t0cgr 64x J4 CR!!0 *ID.N ZRa ZEN! ii I , 1 1 57 6 OF 61 fubw 6010 MECHANICAL MEZZANINE FLOOR PLAN SCALE Ns" = 1 PARTIAL ROOF PLAN SCALE: Ya "= !' -0" —tA it �x\S�I�lC H01 D 11Z WO6171113__ II Z4z1�E G I iE� iG�.�GRS CO c s a CFly1 `y � 1 BO GFM s T , 24.62 Sc- +-1 1 'I .z E.C. f 3 -- 40 - zasE _._ZAMLI!LQ 4; MESA! CQN ST.. t LP .,REMOVE GAS DR., AIR CONDURINER AND INSTALL :EW'LRITT WEAL CARA`I, AND W I ILECONVEGT - EXISTING G ERNIG AND.D1..471,66K END AL, WOOD SLEEPERS WITH MET DUD RTA11. AS RE .EKED TO CONNECT NEW UNITS TO EXISTING VI 2) Ih:SF''M1M1''''''``{{l!ttREW SMOF L6TECT124S �t OD>iS. 3) NEwlU:vfec�:,`nt 3 CaNTROL WIPING BY>.1MS. 4) POWER W':REi' A. DISCONNECTS Eli 0111 MS. S) D. ICE 7 PER TAT: AND LOCAL COOL'S. RET PLENiim BASC1L D RAFT OAMPER RELI -te � o .;I - cricary —KdQE LIIq$ SUPPLY DN EX SS LNy ANA F - 34 - x TO SF1 54. - 0 l ROO F JAC.R D'A DIY )O ®SECTION 5- ALL, - - Y. " - . - - Fd 0 TV RLZ ED - DAMP ER OVTS717E _FL EX -IS ALR -- 0O14IJECTION I0,1 8 . f J ® FAL 0 0 0 cc SHEET NO. a Il a UST bATE 1 REVISEb owe. G -0414 50, 197.00 M3 W K a3 / Gq 3 OF 4 O 111 0 U z Qz 0 0 4 z (1 5 1-- dh< z p, w_ 0 Y2 U u- (I) 1 �WJ , 3 1+OgY M <{-