Loading...
HomeMy WebLinkAboutPermit M99-0251 - AMERICAN TELEPHONEM99 -0251 12658 Interurban Ave. So. American Telephone City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M99 -0251 Type: B -MECH Category: NRES Address: 12658 INTERURBAN AV S Location: Parcel #: 271600 -0030 Contractor License No: UNITESI176RB TENANT AMERICAN TELEPHONE Phone: 12658 INTERURBAN AV S, TUKWILA, WA 98168 OWNER KAISER GATEWAY ASSOCIATION C/0 BEDFORD PROPERTIES, 12870 INTERURBAN AV S, SEATTLE WA 98168 CONTACT BILL LIEBSACK Phone: 206- 654 -3340 1021 SW KLICKITAT WY, SUITE 104, SEATTLE, WA 98134 CONTRACTOR UNITED SYSTEMS INC. Phone: 206 442 -9454 1021 SW KLICKITAT WY STE 104, SEATTLE, WA 98134 * *** * ** ** *•k * * *•k * *•k ** k *•k * ** k * *•k ***** * * * *** * ******•k* •loft **•k*** *•k *•k *** k * ** k** Permit Description: INSTALL ONE NEW ROOFTOP A /C, UNITW /ASSOCIATED DUCT, GRILLES & DIFFUSERS PER DRAWING. UMC Edition: 1997 Valuation: Total Permit Fee: *•k *•k ** * ** k************• k****• k• k*************• k***• k* * ** * *•k **•k ** *•k * * * * * * * * * * *** Permit Cent Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign lor and obtain this b iding rmit. 1� ,1 Signature:__ __ _ 1 Date: 3O / Print Name:__ o ry GC. � i(. Title: 4SSct t _ Status: ISSUED Issued: 12/30/1999 Expires: 06/27/2000 (206) 431 -3670 8,900.00 29.38 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 12658 INTERURBAN AV S Suite: Tenant: AMERICAN TELEPHONE Status: ISSUED Type: B--MECH. Applied: 12/17/1999 Parcel 271600-0030 Issued: 12/30/1999 LVAAk******AA***k4k**kA*k********ItA4*kkiAAkk**AA**k***.Ak*k*******AA***AA*** Permit Conditions: 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building, Division. 2. All permits, inspection recordS, and:aPProved plans shall be available at the job site prior to the start 'of any con- struction. These,Aocuments are to be maintained and avail able until final inspection approval is granted. ' 3. All construction to be done in conformance with aPproved_ plans and requirements'of the Uniform Building Code (097 ." Edition) as amende.d, Uniform Mechanical Code (1)97 Edition), and Washington State Energy Code , (1997 Edition), 4 Validity of Permit, The issuance of a permit or of plans, specifications, and computations shall not be con- , strued, to be a permit for or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction: No permit presuming to give authortity to violate or cancel the ,provisions 't this code shall be valid. 5. Manufacturers installation instructions required on site for the building inspectors review. CITY OF TUKWILA Permit No: M99•025I MUM.. ■•••■•••• Project Name/Tenant: fi � 1 Value of Construction: 6 no ,, S dress :. Cit Sta /Z 13(��$ 11ntU,vu fih I�a ' Tax Parcel Number '1 t- 0ll30 Property Owner: ! ,� 4 ,_,, 1 L e S Phone: Phone: Street Address: J City S to /Z (5u a(lu -� W4,.� 7 /T Cd. 61 e Fax #: Contact Person: V) i I 1 Ue h ry.. \ Phone: T, 65y. 3'f 0 Street Address: City State /Zip: /A 5,u). Klii.irtze, U )aa �•I-' NV 9?3I - W ii.3 q4?1 Fax #: 2o/ ( '( 5if0C Phone: 26(0 - 1 4 _ Contractor: 11 I ?( L� �Et? tM Tier , Street Address: City State /Zip: fin ( ' I.tJ, I<(1rf1l €,■F Ulf, � 1,6i-u. Ivy ,9 ?,bi -ge, (,t)a ht. ?(I Fax #: 20(p (e)'ii M Architect: l Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS ` ,PERMIT'REVIEW 'AND .'APPROVAL REQUESTED: (TO BE : FILLED ;OUT BYAPPLICANT).', Description of work to be done: 1NI. ; .3 0,4,, 11 6u t c� a (u 11 i 1 .t S/'(S per ri) It.13 Will there be storage of flammable /combustible hazardous material in the building ❑ yes no Attach list of materials and storage location on se.arate 8 1/2 X 11 •a.er indicatin• •uantities & Material afet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition ❑ Fence Mechanical ❑ Manufactured Housing- Replacement only ❑ Parking Lots ❑ Retaining Walls Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF TL WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 'Project Number: Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT :REQUEST.FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt it Size(s): ❑ Water Meter /Permanent # Size(s) ❑ Water Meter Temp it Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load /Hauling ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer it: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only WATER METER DEPOSIT /REFUND BILLING: Name: Address: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted :: • IT q City /State /Zip: Date pppllcilepl Phone: Application ken by: (Initials) BUILDING O NER OR TH RIZED AGENT: Signature: l91 4 Date: /A , l 7 . qq Print name: Jt t k tl e ( n z";( (, Phone: 65 , i , � Fax # :Ayo ( pi Address: iu ),( �jld. 1 ��tGtttt�L �� ��IAi� WI City /Stale /Zip: ,. (.4)3 (m13 ALL MISCELLANEOUS ,' MIT APPLICATIONS MUST BE SU' ' TTED WITH THE FOLLOWING: D ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW ❑ Above. Ground.Tanks/Water':Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width . which exceeds 2:1 ❑ ❑ ❑ ❑ Antennas /Satellite Dishes Awnings /Canopies No signage Bulkhead /Dock Commercial. Reroof:' Demolition: Fences - Over 6'feetin Height Land Altering /Grading /Preloads Loading;Docks Mechanical (Residential & Commercial) Miscellaneous Public Works `Permits :. Manufactured Housing:(RED INSIGNIA .ONLY) Moving .Oversized.Load /Hauling Parking Lots Residential Reroof - Exempt with following exception: If roof structure to be repaired :or replaced Retaining Walls - Over 4 feet in height Temporary; Facilities Temporary 'Pedestrian" Protection/Exit 'Systems: Tree Cutting :. • Submit checklist. No Submit checklist ' . No: M -1 CommerrcialTenaht .Improvement Permit • Submit checklist.. No: M -10 Submit checklist:': No: M -6':; 'SubPnit.checkiist No Submit checklist: No:. M -9 Submit checklist .. No: M=2. Commercial Permit: ` ..StJbrnit `checklist No: H 17 Submit'ch'ecklist ! No:: Residential only H -6, H -1.6. Submitchecklist ;.No: 1+9 Submit:checkUst . No :, M�5 Submit checklist No: M =5 • Submit'checklist. No: M -4 •Residential;Building Permit Submit checklist:. No:. M -6 .Sitbniit ciieclilist No: >.M4.:. Submit checklist " o: M-7: Submit checklist No :: M4: Submit checklist • . No: M -2 ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building :Owner /Authorized Ageht, If the appllcantis.otherthan the owner, registered architect/engineer, or,contractorligonsetl by the State of Washington,:: a notarized letter from :the propertyowner authorizing the agent :to submit this permit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 �ITY OF TUKNILA. NA `**k*++AA+*+++++++*+++++++*+*++* M 9 - ( ) ; L 5 8^ *`**+ ^^*+* k it+�4.** +*+*+* * �1c+* *k a++* |kANSMIT Kumb r 9800227 Amnunt: 47.0O O1/31/00 14.121 Payment Mmthodx CHECK NotKtjon: UHITIE,D SYsTgNG Init: NEk ?RANSMIT __,__~,_Y._^ Permit No: M99-025) Typo: Q- NFCH M[CHANICAL YE�MIT I' 4r o{ No: 271600-0030 �itp Addreeu: 1:1658 INT1r,H @AA AV G ' Tota) Fwesx 423,Jn Thia Pavmelnt 47..0O . 7o u| fl L. Pmt • `� 1�3.38 �nc� : �� � '' �`� ^`' � � � �+ ` � �� + � * ��+\4 + /a*a,� • *��+' ^�^a^a��+* **+�^��� o+�x�*� * *++�+ � + '*+a +* + + '' �~ n C d � i ) � ^ H ccoo : o 9� `� UHy�� U�� 'on ` ' ' ' 000/32„.).0O0 � UU1LU%N�'IVESJ][OAT ^'��i���. P ' ~^~=` � ~°^� `.^'.�'- �^`.-- �_ `�, ., � ^'' ._� _' - ^ ; . `- ~ .~~. _,'--�.~_'.''~..'..�....--'~..--�—� _'— _ —. ITY OF !UVULA. NA x7»� ' +�+ *+��+*�+* � *�*+**»4a»a��+ *+ ��+* ��� ' * *A *�* � ** *++* *+*+^ **h+* ++^+ tl �� ��~- y�°>"~1 '' "' ~ ""� ^^^ �*�x` ^ + ( ' ' � ^fi+A�+«+*+**+A**�*�**+/*«*** ,+�*+*�+��+*+�w* �, ^� *^ `` " |RANSMIT Mvmhr: R9800225 Amountx 47.00 01/26/00 14:51 Pavment Met'od: CH[CU Notation: UNITED SYSTEMS NEK Per o : M99 0251 Parcel No: 271600-0030 • Site AJdrosgz 12658 INTER This Pavment Acc0Vnf: Codp 00O/322.800 • • 417.00 �escri BVIi8I T Tutal ****,..,A*** ption NO INVEST � S La) Fee;-; � �'76.J8 ALL Fmtv: ' ; 76,38 Balance: " • lPANSNIT Type: 8-NECH MECHANICAL PERMIT URBAN AV URDQN AV a***+*****a*«aA*aa *A^*+** ' ' Amount 108TTON ' 47.00 0Q ' T' .. . ::5 ?rail: **4 kk:k t ** *kk F AA kk- I.A.A*A4- kA• h• k•. 1: 4** A. 1, ha•, 1****a•:k•h:F:Fk:l .. 1• U 1{ >'t r. 4. �� ,. WA — � 1 1 r� i N S 1 4:A* *A tit Ak8Nic **A- h- kkA.A.*.A•.k:,A:F k1 Ak k: 1: 1* k: e. l: F •ka•AAA..k ***A•.ka•k***Aa;l•:hk 4lthiN9M3:T• Number: P9800211 Amount: 2`) s8 12/20/99 I;!c1cl 1'G(inen'c't4e CHECK Nnt;at;ii)I1e UNITED SYSTEMS Iniis fLL. Permit m•i•t No: 1499' 0251 Tvac' 13-'Mf:C1'1 t41:CHANICAI,. PERthI'r Farc:e 1 Not, 271600 --0090 Site Address: 12658 ',INTERURBAN AV :3 Total Feet3 1 h i h Payment '_"i .:3'1 T' to 1 ALL Pmts t 13 :c 1 anc e r. r** Ait*•* ir*•*•*'****a h*• ir***i*..k* *•**:t•A ** **ir•k * **A,t * *:•k *A• *�* *rkir * Amount, 21 „5() Account; Conde I)eccr •i Ut ion 000/05.830 PLAN CHECK NtlNE.E 000/322. 1.00 Mt;C11ANICAI.' .- NOWI) S 0 ' 1031 29418 M !' DC1) f .5.88 i'i _ 'r�Cr? 23.`:0 ','1 Gt! 29.30 .�t 12/30/99 19 • 14 0097 )(28 • Proje t: A Dip i Ai AA., • • Type of Inspeclon: , 1 1 Vvit I Address: 1 )..toca INNievVyleCoN Date called: ■ 1 - - 000 Special instructions: .., Date wanted: a.m. 0 0 p.m. Requester-t; \i Phon506 cp• sm- 1)-10 INSPECTION NO. 1 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 98188 PERMIT NO, - 2O6434367O Approved per applicable...codes-7.- orrections required prior to approval. COMMENTS: e ro $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: P akiLit-e-di - A. 1-el., Type I inspett Ad ress; ci 04,7 ifr iii. oi Dat c II A? pecial instructions: Datr A , (1 c P.m. Regiteger_i C-'7- Pb ,;, INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 98188 PERMIT NO. (206)431-3670 El Approved per applicable codes, ,Corrections required prior to j$ COMMENTS: s'eL /47,e6f- 2 .74 e 4 e Ee (S tot. c.T7ord Da7 7 00 REINSPECTION FEE REQUIRED. Prior to inspection, e must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: Pr Ahtleit41, Type of Insp ction: an hitti / 6 Date call 1/(: V U Special instructions: Date wanted: , Red a m• Requester: 64 Phone: - 3 INSPECTION NO. INSPECTION - RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 "rY• .. +tr , :tia�+.*t= ::•',sir= �•^�r;u• .i'.'.'" "J=T+' «"u:.7.'".ia , PERMIT NO. (206)431 -3670 \ ) Approved per applicable codes. COMMENTS: 7/1 cir `63 13 i"7 0 V- - e- -7-7, % ? E ( In nectar: — - Date: 1 <orrections required prior to approval. vi $47.00 REINSPECTION F 7 REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: P ‘.'e t: . _ILL-1 LA Typ: ofinspectio/ A -ag . -A. c 13 Date 007) pecia instructions: Eat %/hied: / /9/2O( a.m. Req esxdp (06/ ' Approved per applicable codes. g Corrections required prior to approvac • COMMENTS: ,., 411 .4■1 AMPAII )4:) C.../. 1 2) 4e../ei 1: (C_ , c ' -, A7 de <-7 S,ai- A* Ara- 7 / 5 e9 -, 4 / — ! / 0 . ..e.. .dicat... .. . -..."1".1111 _ 1/ — ../ --- w...... 411, / —,...arliWAIV , _ ....— _ Ail 0 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Inspector: 1NSPECTION.RECORD Retain a copy with permit -63 Date: PERMIT NO. (206)431-3670 El $47.00 REINSPECT! 1 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pr Typ1f Inspection: .L( / /3i /t A ess: A /4/e5 Date WOO r Special instructions: Date wante1/ t�0 a.m. p.m. Requester: 3C� INSPECTION NO. INSOECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 A pproved per applicable codes. fl Corrections required prior to approval. COMMENTS: • $4‘. 0 REINSPECT! N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.; Suite 100. Call to schedule reinspection. Receipt No: Date: cec ze.taiem Typ� /io v ( V yA! Ad�lrc� : � c 'e 3 -, Date called: (7 o • �--.. Special instructions: Date wanted: � /_ l a}n. p.m. JJ,/J Requester: `�%(.�" •• ZU Ej Approved per applicable codes. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION Ft'ECORD Retain a copy with permit PERMIT NO. • (206)431 -3670 Corrections required prior to approval. COMMENTS: 4 c L d',( - e> cv") Date: El $47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pr ect: / �1'1��'��1(�� 1'7 "� .. Type of In echo � ddr ' � ios�Sg .9I �i�.G / wC' 5 ,- ; Date called: 1/ 4 00 Special instructions: Date wanted:' " a.m. . P Requester: Phone: N" f INSPECTION NO. %Approved per applicable codes. INSPIECIION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 tY1 005i PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: j) k S ' , 19,12 'fa � iH d ly�� .s.1,ei y A-74(c,/i2c L1 $47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No: z Date: i a� DEC -16 -99 THU 05:05 PM HARTING II R $ARTINC, JR./CONSULT/NC .ENGINEER 272 WELLS Ave. 5., F, RENTON, WA. 90055 PHONE (425) 271 -4242 w r N A RAu OEC 2 l 1999 CI TTUFTVY 1.t PROVED CONSULTING ENG. 1 425 235 6068 P.02 C DATE' v JOB ND, SUBJECTt A G, - nLT -uP WALL Rep .JAM 1 Icau I _ EPF4 'J PA • : Y, . - sk4 sL1EET' DI 3 CPPy OF DEC 1 -I 1999 PERMIT CENIER LI iT. 7 L.PO M E H T PtAU . /1W - I L_o„) 2 (O58 ikiT"Euw TU,KWIL.A WA, DEC -16 -99 THU 05:05 PM HARTING CONSULTING ENG. 1 425 23.5 P 0S N R NARTINC, J.R. /CONSULTINO ENCINEFR 212 WENS AVE. S., SUrTE r, RENTON, WA. 98055 PHONE (425) 271 -4242 N14T + /I X 1 4 � u PuKuu��{ 1`fPE N K L3 Xi X' X D :' "CfP AWW(LE /-(70 ".4X 'T' L4 eDuS .. .X . 3 L " L, ED PARkLL H . rd CL:. b -1•l) JOB NO,' SUBJECT/ JOB' - AL' EJ Cpl - ---4 k - -- a RN/L/0F 3 /guy Ex. Fol - ci.E pp i a11a. i le)fie Itar • A _ PiRtLL'M To 4x4 ���.. I - SHEET. NEw. HUG. -oho HvAc. uUlr MR 1ETAl.GJe E378 TDT7 L -( " c.0 f alp i 7 1999u P MIT CORM RCCF' DTI FFELIEE qXl� FURuA 3.X 9+4 .Rkplll. M VAC U lT 1 LI9\01100 F RAM 104 PLAO (scii r! IIy��F •1 �-n + +� DEC -16 -99 THU 05:06 PM HARTING CONSULTING EJNIG !I R HURTING, .!R. /OONNIZT /NG ENGINEER 212 WEDS AVE. S.. SURE F. RENTON, WA, 980S5 PHONE (42S) 271 -4242 114 VAT li,V4 RAY 11-1 "1X ru RLI 1,,k1 C;V -P L AM . . X( NV -E c;u r PoRr �t•Li l� . L S :9 g .UC 1S 9 X i4VAC.. .1 P U PF) Rr Ell .R1 JOBS JOB NO SUBJECT' 1 425 235 6068 r ; • P.04 SHEET 3 - 41/6 "X 32V/e X 82 . 4 4" I-4VAG u LI IT. I26A (. .R56 24uoLMAX zi+MET ,\L cURE,w/ 1/4q X 7 . %C LM OLTs 2,2411 Mk( tYP . cI D 1 Fl ui &M, COO. Wi9 loW4(sidulta etY OF bi,C A 7 \999 PEW coma C SS � ��IVA� IThLL1M1c*i DEC -16 -99 THU 05:06 PM HARTXNG CONSULTING ENG.,__1_,425 235 6068 P.05 It R ItARTINC, ✓R. /CONSULTINC .ENCIN64'R \ !-AFL. cam, �`1t��� X• 13" 212 WELLS AVE. S., SURE F, RENTON, WA. 9b055 PHONE (425) 271 -4242 D HN6uc ono H uuir D1kNPEQ At Q bAKPfe C u P.v� .,\ - 5 - &:shAz . — Li I ' 1-A. 1 (,5 .8 0 :-I W c:»4 ,'Z � y b x t : 12_x(2, lu '65:1 lo6X •) ' 4& eck- 14b9. t:: x` _ ' c. Z.22 4# 1( 61 (ia t . (.41 44ti L 50 - slI -t 6 LI X OF-L4tZ ILJ sIHPt.3 L.u • CDt.sc.)wt I F2. JOB L V ~ C ■ 4a • • JOB NW al:{ `99 DATE • L • BY, SUBJECT Olt AC_ I JA•rAU l • SHECTs 1 00 v 2" MOM �1Ste - 1tThL erry 0 U NII DEC 1 7 PERMIT ©ENTE:it Sir 0 uS Sal FFso N u1L — --.� ,. 1 ? `"� of Ca) CO WLA1- -5 *a) ±Z. _c r7" W i ((lc. 6"► FLF DEC-16-99 THU 05:07 PM HARTING IT R N4RTINC, JR. /CONSULTING PNOI ,0R 212 WELLS AvE. S., SUITE F. RENTON, WA. 06055 PHONE (425) 271 -4242 y,IS 11U -► 'PU'2.L1 US LL_ 29 1'5F DL° LJ ( 1 C -1. VS ) CS) = 3 RF 4- 2) 6 27 TV N 112 .02 (75.46 (�Ibi 15),C - 4* ° 28:-‘ ( � (i AV" f . til 410 CONSULTING ENG. 1 425 235 6068 P.06 Jolt, A.4-4 (Ck.3 - S`F Lf. PHOg. JOB NI DATE' SUBJECTI 4-4 uhC. 205 0 I 16 2`1t,q 2 85 1 StiT4 STl'F . l OS0L PP,wt:.uEe SCa GLC-� 2 1' V7,0 A13,95 rto 54341 ca►c- (■,k) 2/61/ 110 (IZ� (1 ) SHEET' 2. 5 -(. _ ( 2 2 5 • 2 , ck � -- 41117) � N ty.17 ►�� 2-1.,0 DEC -16 -99 THU 05:08 PM HARTING CONSULTING ENG, 425 235 6068 H .R N!l?TfNc JR/cLW$CILTlNG .ENGINEER 212 WELLS AvE. S., Stint F, RERTON, WA. 9EO55 PHONE (425) 271 -4242 eok- JOB NOt -. DATE) (z SUBJECT' ■ �'� P.07 JOB. 4 ke# ) '[ 't -l)UE 1 BYE Re CIA° I A tEC 1 1 ek99 PEF10 GETTER SNErn ' 1,1; c . 3 7y+ - 3 32;) b . ' i z.3a `, M1. 5 ( &C ) 4Wz . Te-) L3". :11°Z.-(eb38'%)* ani--- 'E ;x y , 14't,02...-+ '1A- ( s5 ^ �'�� Wes+` 2. - ( 5m t 3 u 3/64)((1" L- C131:t S 2L10 # 1 G iwt u 1-.) D ROL-Wit) - 1.1k4 .L,1 I s' cr_ ! !L 3/tot4 kt" 4:61-mta-m, ! 6 i ,i o 9L 5zax=cN C IMRE SINGLE PACKAGE AIR - COOLED CONVERTIBLE SERIES AIR CONDITIONERS DDHB 036, 048, 060 & DBHB 072 DHUC 036, 048, 060 & DBUC 072 3, 4 AND 5 NOMINAL TONS (10 SEER) 6 NOMINAL TONS (9 EER) CITY OF R}O O APPROVED DEC 2 7 1999 l`dUii U w 4�U1LC�1�!� 1�1V �it)fi RECEIVED CITY OF TUKWILA DEC 1 7 1999 PERMIT CENTER MODEL DUC DESCRIPTION The DHB and DUC units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for residential, Tight commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self- contained and assembled on rigid full perimeter base rails with fort lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factoryto provide fora quick and easy field installation. The units are available In cooling only, and cooling with gas heat. Electric heaters are available as field - installed accessories. The cabinet is constructed of galvanized steel, painted with long lasting, durable, and aesthetically pleasing power paint. Paint finish meets 750 hour salt spray tests per ASTM-B117 standards. AU models include a 5 -year limited warranty on scroll compressors and electric heating elements, a 10 -year limited warranty on gas -fired heat exchangers and a 1 -year limited warranty on all replacement parts. FEATURES MO5f 0ntd. 530.18 -T41 L (698) COMMON FOOTPRINT/COMMON CABINET - All model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. He can even decide between gas or electric heat after the curb has been set.h HIGH EFFICIENCY - All units have a high cooling efficiency, and gas / electric models have a minimum AFUE of 80 %. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side retum is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / bottom retum Is desired, you simply remove the two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required) Convertible airflow design allows maximum field flexibility and minimum inventory Economizers may be used on either bottom and side duct applications with no modifications required. FACTORY - INSTALLED OPTION - Adjustable belt -drive blower Is available on all models from the factory to provide maximum air flow flexibility. FIELD - INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided in the intemal partitions to connect the elements to the control box single point kit. The motorized air damper includes a slid - in/plug -in damper assembly with a rainhood and filters. The outdoor air dampers open when the indoor fan motor Is energized. The damper Is capable of providing 0% through 100% of outdoor retum air opening. 530.18 -TG1 FEATURES - CONT'D. The manual outdoor damper provides 0% through 35% or 0% through 100% of return air opening (field adjustable). Designed for duct mounted side or bottom supply /retum applications. Includes rain hood assembly and fitter. The 14" high roof curb is shipped knocked down. An insulated deck is not required because the bottom of the unit is insulated. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0°F. Propane, high altitude and low NOx kits are also available to cover all gas heating applications. WIDE RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5 -ton models operate over a wide range of design conditions with a 3 -speed direct-drive fan motor. The 6 -ton unit has a single speed direct -drive fan motor. Belt -drive blowers are also available on all models. FULL PERIMETER BASE RAILS - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. SYSTEM PROTECTION - Internal overload protection are HIGH - EFFICIENCY CONVERTIBLE ROOFTOP ECONOMIZER HOOD OUTDOOR AIR OPENING FOR SUDE•IN/PLUG IN INTERNAL ECONOMIZER (ACCESSORY) SIDE RETURN AIR (Return OPENING at Side by Air d d e) Supply Jr A BOTTOM RETURN AIR DUCT OPENING Side b Alter Ws) Air LOW VOLTAGE RELAY BOARD 20 GAUGE ALUM NIZED STEEL AND TERMINAL STRIP TUBULAR HEAT EXCHANGER ELECTRICAL DISCONNECT MOUNTING LOCATION (Field Installed) 314 PVC FEMALE CONDENSATE DRAIN KNOCKOUTS FOR SIDE POWER AND CONTROL ENTRY standard on all scroll compressors. Every unit h DIRECT•DRIVE BLOWER MOTOR (Belt•DrIve Option also available on some models) TERMINAL BLOCK (For Single Point Power Supply on Elec/Elec Units) lig Description 1 Features 1 & 2 Ratings 3 Physical Data 3 Cooling Capacities - 3 Ton 4 Cooling Capacities - 4 Ton 5 Cooling Capacities - 5 Ton 6 Cooling Capacities - 6 Ton 7 Blower Performance - 3 & 4 Ton w /Belt -Drive 8 Blower Performance - 5 & 6 Ton w /Belt -Drive 9 Blower Performance - 3 - 6 Ton w/Direct -Drive 10 Option and Accessories 10 2 t ir. < � - Y '617/ 4 41:i g TABLE OF CONTENTS filter- drier, high and low pressure/loss at charge switches and a suction line freezestat to protect all system components. All units will provide cooling at ambient temperatures down to 45°F. UTILITY CONNECTIONS MADE EASY - Gas and electric utility knockouts are provided in the unit base as well as the side of the unit. Aclearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. SIMPLE CONTROL CIRCUIT - A low voltage printed circuit board contains a scroll compressor lockout indicator Tight and a low voltage terminal strip. An additional set of pin connectors is also provided to simplify the field interface of external controls. Mate -n -lock plug connectors are used where line and low voltage wires pass thru intemai bulkheads. This allows for easier troubleshooting and component replacement. The electrical control box is not located in the scroll compressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures. All wiring internal to the unit is color /number coded. AIR FILTERS - Units are shipped with 1" disposable filters. The unit filter racks can accommodate 1" or 2" filters without any modifications. ELECTRIC ACCESSORY LOCATION (E AIec/Elec Units) KNOCKOUT FOR BOTTOM GAS SUPPLY ENTRY KNOCKOUT FOR BOTTOM POWER ENTRY POWER VENTER MOTOR KNOCKOUT FOR SIDE GAS SUPPLY ENTRY COPPER TUBE / ALUMINUM FIN CONDENSER COIL HIGH EFFICIENCY SCROLL COMPRESSORS BASE RAILS WITH FORKLIFT SLOTS AND UFTING HOLES MODEL DUC (Gas Heating) Static Resistances 11 Motor and Drive Data 11 Electrical Data - Basic Units w/Direct -Drive 11 Electrical Data - Basic Units w/Belt -Drive 11 Elec. Data- Clg./Elec. Htg. 3 & 4 w /Direct -Drive 12 Elec. Data- Clg./Elec. Htg. 5 & 6 w /Direct -Drive 13 Elec. Data- CIg./Elec. Htg. 3 & 4 w /Belt -Drive 14 Elec. Data- CIg. /Elec. Htg. 5 & 6 w /Belt -Drive 15 Field Wiring 16 Unit Dimensions 17 & 18 Roof Curb Dimensions 19 Component Weights and Center of Gravity 19 Typical Applications 20 Unitary Products Group CAPACITY RATINGS - coolln 1 tiectnc maim MODEL - ARI RATINGS NOMINAL ELECTRIC HEAT CAPACITY (KW) STANDARD CFM COOLING CAPACITY 80 / 67 -95 °F SOUND RATING (dbels) MBH SEER EER 240V 480V 600V DHB036 36.0 10.00 ;9.10; 82 5 7, 10, 15 &20 7, 10, 15 &20 10, 15 &20 1.300 DHB048 47.4 10.00 > 9.00,;: 82 5 7, 10, 15 &20 7, 10, 15 &20 10, 15 &20 1.700 DHB060 59.0 10.00 ';9:10: 82 5, 7, 10, 15, 20 & 30 7, 10, 15 20 & 30 10, 15, 20 & 30 2.100 DHB072 72.0 - 9.00 84 5, 7, 10, 15.20 &30 7, 10, 15, 20 &30 10, 15 20 &30 2.400 CAPACITY RATINGS - Cooling / Gas Heating MODEL ARI RATINGS 1 GAS HEAT CAPAC TY STANDARD CFM COOLING CAPACITY 80 / 67 -95 °F SOUND RATING (dbels) INPUT (MBH) OUTPUT (MBH) AFUE ( / °) S.S.E. ( / °) TEMP. RISE ( °F) GAS LINE SIZE (In. OD) MBH SEER FFR DUCO36N050 DUCO36N100 36.0 36.0 10.00 10.00 . ;'9.10° ;'9.10:': 82 82 50 100 40 79 80.9 80.5 81.6 80.8 15-45 40-70 1/2 1/2 1 300 DUC048N075 DUC048N125 47.4 47.4 10.00 10.00 '.9,00:< 9.00?. 82 82 75 125 59 99 80.9 80.3 81.6 80.6 25-55 45-75 i/z 1/ 1.700 DUC060N100 DUC060N125 59.0 59.0 10.00 10.00 :;9.10 ':9.10 >` 82 82 100 125 79 99 80.5 80.3 80.8 80.6 25-55 35-65 1/2 1/2 2.100 DUC072N100 DUC072N125 72.0 72.0 - - 9.00 9.00 84 84 100 125 79 99 80.5 80.3 80.8 80.6 25-55 35-65 1 /2 1� 2A00 MODELS DHB/DUC 036 048 1060 1 072 EVAPORATOR BLOWER CENTRIFUGAL (Dia. x Wd. In.) 12x10 12x10 12 x 10 12 x 11 FAN MOTOR HP (DIRECT-DRIVE) 1 3 /4 1 1 FAN MOTOR HP (BELT-DRIVE) 1 11,42 11/2 11/2 EVAPORATOR COIL ROWS DEEP 3 3 3 4 FINS PER INCH 13 13 13 13 FACE AREA (So. Ft.) 3.6 4.3 5.1 5.1 COMPRESSOR TYPE HERMETICALLY SEALED BRISTOL SCRO CONDENSER FAN PROPELLER DIA. (In.) 24 24 24 24 FAN MOTOR HP 1 /4 1 /4 1 /4 1 / 4 ,•„ ak • •. • , ..11 •,11 • CONDENSER COIL ROWS DEEP 1 1 1 2 FINS PER INCH 16 16 22 16 FACE AREA (So. Ft.) 17.1 17.1 17.1 16.7 AIR ILTERS FILTERS (SEE NOTE) QUANTITY PER UNIT (15" X 20" X 1") 2 2 2 2 QUANTITY PER UNIT (14 "X25 X 1" ) 1 1 1 1 TOTAL FACE AREA (so. tt.) 6.3 6.3 6.3 6.3 CHARGE REFRIGERANT R -22 (Ibsior.) 5/8 6/8 6/8 10/0 C RATINGS 1 Ratlrge are In accordance with ARI Standard 210. 2 Sound ratings are In accordance with ARI Standard 270. 3H eaters are available as accessories - ate with single point pow supply. SEER ■ Seasonal Energy EQdenoy Rath • the btai cooling ouput in BTU's during a normal smuel usage period br cooing clinked by the told electric power input In watt -hours during the same period EER - Energy Efficiency Ratio • the cooling capacity In Btu's per hour (Btuh) divided by the power input In watts at any given set of rating conditions, ergxessed In BTUH per watt (BTUHAvatt). AFUE - Annual Fuel Utilization Efficiency • dotennkad In accordance with DOE lest procedure. S.S.E. - Steady Stars EMdency. (Percent Output). .':'. Not ARI Listed. PHYSICAL DATA - BASIC UNITS NOTE: Filter decks are adsplsd for 1' or 2' thick Alters. Unitary Products Group 530.18-TG1 3 Air On Evaporator Coil Temperature of Alr on Condenser Coil 105 °F Total Cap.' MBH Pow Input KW 85 °F Sensible Capac ty , MBH Total Cap.' MBH Powe[ Input` KW Powe Input KW Sensible Capacity , MBH CFM W B °F Entering Dry Bulb, °F Dry Bulb, °F 86 Enteri Dry Bulb, °F 86 83 80 77 74 71 68 86 83 77 74 71 68 1750 72 67 62 57 4 S C! C! • C.3 N RI 4 30 38 39 40. 2:1 A 4 21 29 34 35 17 25 30 31 - 20 25 26 - 16 21 22 43 41 36 38 3.3 3.3 3.3 3.2 g;t:A,A 30 38 : 36 ''38 26 34 36 , 38::- 21 29 32 33 17 25 27 29 - 21 23 24 - 16 18 20 1475 k i„ rt 72 67 62 57 62 57 3.7 3.6 3.7 3.6 7qc:I C, C) 07 N 0) Ct, 01 N V, 01 N ;7, g3, g3 28 35 38 " 39 24 31 37 , ,39. 20 27 33 35 16 23 29 31 - 19 25 27 - 16 21 23 42 39 36 37 3.3 3.3 3.3 3.2 Z•3 g3 X It to c%I. 27 35 36`x. 37 23 31 35 20 27 31 32 16 23 27 28 - 19 23 25 - 15 19 21 25 32 36 37 22 28 35 37 18 25 31 34 15 22 28 31 - 18 25 27 - 15 21 24 41 MEM= 35 36 3.3 3.3 32 24 31 , ' , 35'' 36 < 21 gm 34 35 18 25 30 32 14 21 27 28 18 24 25 15 20 22 1050 72 67 62 57 23 30 ' 35 .. .36 20 27 33 35 17 24 30 32 14 21 27 29 - 18 24 26 - 15 21 23 39 37 33 34 3.2 3.2 32 3.2 23 29 33 ' 34' > 20 26 31 32 17 23 28 30 14 20 25 27 - 17 22 24 - 14 20 21 900 72 67 62 57 39 37 34 34 3.1 3.0 3.0 2.9 24 30 _ 34 .' 34 21 27 33 "34 19 25 30 33 16 22 28 30 14 20 25 27 - 17 23 25 - 15 20 22 38 36 32 33 3.2 3.2 3.2 3.1 23 29 „ < 32.` . 33 ' 21 26 31 ' 33 ` 18 24 29 30 16 21 26 27 13 19 24 25 - 16 21 4 .. - 14 19 20 Air On Evaporator Coil Temperature of Air on Condenser Coil 105 °F 115 °F Total Cap.' MBH Powe Input KW Sensible Capac'', MBH ty Total Cap.' MBH Powe Input KW Sensible Capac ty MBH CFM W B °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 1750 72 67 62 57 ;1-2A2 3.7 3.7 3.7 3.6 I AAAA 29 37 ;34 '35 25 33 .'34 . 35 20 28 30 31 16 24 25 26 - 19 21 22 - 15 16 17 39 36 32 33 A 01 28 ; 38 : 32 , 33 ` 24 ..32. :32: 33 19 27 27 28 15 23 23 24 - 18 18 19 - 14 14 15 1475 72 67 62 57 40 37 33 34 3.7 3.6 3.7 3.6 S ARA (4ARA 23 30 . 33. > 34 ' 19 26 29 30 15 22 25 26 - 18 21 22 - 14 17 18 A 7qqc:1 26 33 ; 31 32' 22 29 31 :: 32 : 18 25 27 28 14 21 23 24 - 17 19 20 - 13 15 16 1200 72 67 62 57 39 36 32 33 3.7 3.6 3.6 3.6 ( A gi 24 30 32 33 20 27 32 • 33`` 17 24 29 29 14 20 25 26 - 17 22 23 - 14 19 19 37 34 30 31 '7qC1 • nr l 0) 26 33 30 ' ' 31 >'. 23 30 30 31`' 20 26 .30 "S31 " 16 27 27 13 20 24 24 - 16 20 21 - 13 17 17 1050 72 67 62 57 37 35 31 32 3.6 3.6 3.6 3.5 25 31 , 31. 32. 22 28 : -31." •32 19 25 29 30 16 22 27 27 13 19 24 24 - 16 21 21 - 13 18 18 l g S 0 0 cl? 21 27 29 29 18 24 28 28 15 21 25 25 12 18 22 22 - 15 19 19 - 12 16 16 900 72 67 62 57 36 33 30 31 3.6 3.6 3.6 3.5 22 28 30. 31 20 25 29 30 17 23 27 28 15 20 24 25 12 18 22 22 - 15 19 20 - 13 17 17 34 31 28 28 4.0 4.0 4.0 3.9 21 27 , 28 28` ; 19 24 . `28 16 22 25 25 14 19 22 23 11 17 20 20 - 14 17 17 - 11 15 15 ( 530.18-TG1 COOLING CAPACITIES - 3 TON (DHB / DUCO36) I These capadl ee are gross mange. For net capacity, datemdne the KW of the supply ak Now motor Iron the Blower PeAomhrhoe Table, mufrpty link valus by 3.415 MBH / KW b determine the mobr heat, and deduct link heat from the groan capacity of be ult. 2 Those ratings Inckido the compressor and the condenser fan motors but not the supply air blower moor. The blal oondenaor fan motor power Input Is 0.38 KW. Rater b the slower Performance Table for the KW of the supply ak blower motor, 4 Inn NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group Air On Evaporator Coll Temperature of Air on Condenser Coll 105 °F 115 °F Total Cap.' MBH Powe Input KW 85 °F Sensible Capac ty , MBH Total Powe Input KW Sensible Capacity , MBH CFM CFM WB °F Enterin D Bulb °F Cap.' Enterin. D Bulb 77 . °F 74 71 68 86 83 80 77 74 71 68 MBH 86 83 >Z r f- 72 60 31 44 39 33 28 23 - - 60 4.5 44 39 33 28 23 - - 2000 67 55 •:r 53 48 42 37 32 26 21 52 4.5 52 47 42 36 31 25 20 62 51 45 51 :51 51 45 40 34 29 48 4.4 48': 48 '48 " 42 37 32 26 57 49 44 <'49 49 : 49 ' 44 39 33 28 47 4.3 47: 47 47 . 42 36 31 26 5.0 72 58 29 41 36 31 26 21 - - 57 4.5 41 36 31 26 21 - - 1800 67 53 38 49 28 40 35 30 25 20 50 4.5 49 44 39 34 29 24 19 4.9 62 49 43 ..49 :49 48 43 38 33 28 46 4.4 46 : 46 46 ` 41 36 31 26 4.9 57 47 43 ' 47 "47 ''47 43 38 33 28 45 4.3 45 45 45 40 36 31 26 5.0 72 56 28 38 34 29 25 20 - - 55 4.6 38 33 29 24 20 - - 4.9 44 51 •;t: 46 '47 41 37 32 28 24 19 ' ` >= 45 40 _: 31 27 23 18 4.9 62 47 42 ' " '47 . 45 41 36 32 27 39. 44 44 26 40 35 31 26 4.8 57 46 41 46 :46 46 41 37 32 28 © ` 39 ` 44 44 25 39 35 30 26 5.0 72 54 26 35 'c; 27 23 19 - - 53 4.5 35 31 - 23 19 - - 1400 67 49 29 42 34 30 26 22 19 47 4.5 41 38 20 16 26 22 18 40 62 45 35 ''45 42 38 34 30 28 43 4.4 43 43 24 37 33 29 25 . 40 57 44 34 ::44 43 39 35 31 27 42 4.3 '42 ` 42 24 37 33 29 25 4.9 72 52 4.1 32 29 25 22 18 - - 51 4.5 32 28 - 21 18 - - 1200 67 47 4.1 39 35 32 28 25 21 18 45 4.4 38 35 19 28 24 21 17 4.8 62 43 4.0 .43. '43 39 36 32 29 25 41 4.3 41 41 22 35 31 28 24 Alr On Evaporator Coil Temperature of Air on Condenser Coil 105 °F 115 °F Total Cap. MBH Powe Input KW Sensible Capac tv MBH Total Cap. MBH Powe Input KW Sensible Capac ty MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F :3 :0 74 71 68 86 83 . 80 77 74 71 68 72 56 31 28 21 - - 53 5.6 35 29 24 19 . - - 2000 67 49 to 40 35 29 24 19 46 5.5 44 . 39 33 28 23 17 62 45 45 39 34 28 23 41 5.4 .:41 41. 36 30 25 20 57 44 44 39 33 28 22 41 5.4 :41. 41.:. 35 30 25 19 72 5.0 39 29 24 20 - - 52 5.5 33 23 18 - - 1800 67 5.0 47 . 38 33 28 23 18 45 5.4 42 32 27 22 17 62 4.9 43 43 38 33 28 23 40 5.4 40 35 30 26 21 57 4.9 43 43 ' 38 33 28 23 40 5.4 40 ` 35 30 25 20 72 53 5.0 36 28 23 19 - - 51 5.5 31 26 22 17 - - 1600 67 46 4.9 44 4 35 31 26 22 17 44 5.4 41: 39 35 30 26 21 17 62 42 4.9 42 . 42 37 33 28 24 39 5.3 39. ., 39 `:. 35 30 26 21 57 41 4.8 41' 41 37 32 28 23 39 5.3 39 ` ` 39 ` 34 30 25 21 72 G444 5.0 33 29 26 22 18 - - 48 5.5 32 28 24 20 16 - • 1400 67 4.9 41 37 . 33 29 25 21 17 42 5.3 40 . 36 32 28 24 20 16 62 4.8 40 '.40 39 35 31 27 23 37 5.3 37 ; :37: 36 32 28 24 20 57 4.8 . 40 40 38 34 30 26 22 37 5.3 . 37 : `' 37 36 32 28 24 20 72 49 4.9 30 27 23 20 16 - - 48 5.4 29 26 22 19 15 - - 1200 67 42 4.9 37 34 30 27 23 20 16 39 5.3 36 33 29 26 22 19 15 62 38 4.8 :' 38 `: 38 : 36 32 29 25 22 35 5.3 35 :: 35 33 29 26 22 19 COOLING CAPACITIES - 4 TON (DNB / DUC048) 530.18 -TG 1 These capacities we gross rulings For net casndly, deism** the KW of to supply air blowernobr from to Blower Performance Table, mutiply this value by 3.415 MBH I KW b determine to rnobr heal, end dsdud INa boat from the pose capacity of the uNt 2 These name inoltde tine compressor end tre condenser fart rrabrs but not the supply air dower motor. The loth condenser fan mote power Input Is 0.36 KW. Refer to the Bower Pabrmance Table for the KW of the supply elr blower motor. Unitary Products Group - NOMINAL RATING ALL SENSIBLE CAPACITY 5 Air On Evaporator Coil Temperature of Air on Condenser Coil 115 °F Total Cap. MBH Total Cap. MBH Po we Input KW 85°F Sensible Capac ty , M x2J..4 .y T otal Cap.' MBH s 4;. .: �..1 Y n Powe Input KW ' a 5„ � ... x:•'73 n. , .l Sensible Capac ty', MBH CFM W B °F Entering Dry Bulb, °F Enterin. Dry Bulb, °F 86 83 80 77 74 J 71 68 86 83 <M't; 77 4 71 68 2500 72 67 62 57 68 62 57 55 4.9 4.8 4.7 4.7 V3 44 56 57 55 ` 38 50 57 ; 55 32 43 51 48 25 37 44 42 Z7, 2 2 - 24 32 29 65 60 53 51 5.6 5.3 5.3 5.4 50 60 ,: 53 51 43 54 53' 51 37 48 :53` ' 51 ' 31 42 47 44 24 35 41 38 - 29 34 32 - 23 28 25 2250 s3' t', t 72 67 62 57 67 62 56 54 0) 0? h: cc. 0? h: co 111 xi- NI* • 4 Lcgsa .`13 IR 2 ;I- 101010 42 53 56 ' 54 39 50 55 . 53 36 46 :53 ' 51 2 8 4 2 2 ;;;i: 4 30 41 50 48 24 35 45 42 - 30 39 36 - 24 33 31 65 59 53 50 5.4 5.2 52 5.3 r'r284n284484 41 51 53 : 50. 39 48 52. 50 35 44 °.60. ' 47 : 35 45 ' :53 : 50 33 .. �. `�';- - t 29 40 47 44 28 38 47 44 26 35 43 41 23 34 41 39 22 32 42 39 21 30 39 36 - 28 35 33 - 27 36 34 - 25 34 32 - 22 29 27 - 22 31 28 - 21 29 27 72 62 57 66 61 55 53 29 39 50 48 27 36 47 44 23 34 45 42 22 32 42 40 - 28 39 37 - 27 37 35 - 23 34 32 - 22 32 30 64 � ti .• 52 50 61 56 50 47 5 3 s 3 5.1 5.2 5.4 5.1 5.2 5.2 1750 72 67 62 57 63 58 53 51 1500 72 67 62 57 8SG4 4.8 4.7 4.6 4.6 37 46 51 ; , 49 33 42 51 . 49 29 38 47 45 25 34 43 41 21 30 39 37 - 26 35 33 - 21 31 29 58 53 47 45 5.4 5.2 5.2 5. 36 44 :.47 32 40 47 29 38 44 42 24 32 40 20 28 36 _ - 24 32 • - 20 27 Air On Evaporator Coll Temperature of Air on Condenser Coil 105 °F 115 °F Total Cap. MBH Powe Input KW Sensible Capac'', MBH ty Total Cap. MBH Powe Input KW Sensible Capac ty MBH CFM W B °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 2500 72 67 62 57 61 55 49 47 .00 10 ui 244 41 52 49 . 47 35 46 49 47 29 39 42 40 22 33 36 34 - 27 30 28 - 20 23 21 1010 8 4 4 6.7 6.6 6.5 6.5 1 44 39 50 44 `. 42 cc3 4 4 27 37 38 36 20 31 31 30 - 24 25 23 - 18 19 17 2250 72 67 62 57 G144 6.0 5.9 5.8 5.8 2 ..4..4 39 49 .48 :46 2 4 4 4 28 38 42 40 22 32 37 35 - 26 31 29 - 20 25 23 57 50 44 42 6.6 6.5 6.4 6.4 4 8 4 4 38 47 44 42 32 42 44 42 26 36 38 36 20 30 32 31 - 24 26 25 - 18 20 19 2000 72 67 62 57 844 6.0 5.8 5.7 5.8 42 52 48 ;' " 46" 37 47 48 46 32 41 48 46 26 36 43 41 21 31 37 35 - 25 32 30 - 20 27 25 57 50 44 42 6.6 6.5 6.4 6.3 8 4 4 36 45 44 '42 " 2 4 4 25 34 38 37 20 29 33 32 - 24 28 26 - 18 22 21 1750 72 67 62 57 57 51 45 43 6.0 5.8 5.7 5.8 38 47 45 : : 43 34 42 45 '`43 29 38 44 42 24 33 39 37 19 28 34 32 - 24 30 28 - 19 25 23 6.5 6.4 6.3 6.3 37 45 41': t.39: 32 41 41 39 27 36 39 38 23 31 35 33 18 26 30 29 - 22 25 24 - 17 21 19 1500 72 67 62 57 13 6.0 5.8 5.7 5.8 30 38 43 26 34 39 _ 38 22 30 35 34 18 26 31 30 - 22 27 26 - 18 23 21 49 43 38 37 6.5 6.4 6.3 6.2 33 40 38 . ` 37 28 36 38 , _ 37 24 32 35 34 20 28 31 30 16 24 27 26 - 20 23 22 - 16 19 18 t 530.18 -TG 1 COOLING CAPACITIES - 5 TON (DHB / DUC060) 1 These capacities are gross ratings. For net capacity, determine the KW of the supply alr blower motor from the Blower Performance Table, mUtlply thie value by 3.415 MBH / KW b determine the mob' heat and deduct this heat from the gross capacity of the unit. 2 These ratings Include the compressor and the condenser fan motes but not the supply air blower motor. The btal condenser tan motor power hput Is 0.36 KW. Refer b t19 Blower Performance Table for the KW of the supply air blower motor. 6 NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group Air On Evaporator Coil Temperature of Air on Condenser Coil 85 °F Sensible Capaci, Tem. = rature of Air on Condenser 3 Total Cap. MBH Coil Powej Input KW Sensible Capac ty MBH Sensible Capacity ' .: : i s...: .. , MBH Total Cap. MBH Powe Input KW MBH CFM 1MB °F Entering Dry Bulb, °F 83 Enterin Dry Bulb, °F 86 83 80 77 74 71 68 86 83 77 74 71 68 2700 72 67 82 57 80 80 70 68 5.7 5.7 5.5 5.6 63 76 .70 '68 55 68. ' . 68 47 60 70 88 40 53 62 60 g 42 g - 37 47 45 - 30 39 37 77 77 71 71 6.3 6.3 6.3 8.3 63 75 71' 71 55 68 ;i 71 .. 71 ' _ 47 60 :71," ' °.71 ' 40 53 63 63 32 45 56 56 • 37 48 48 .244 2550 2100 72 67 62 57 72 II 82 57 72 67 62 57 82 82 71 69 83 83 73 71 79 79 69 67 P;N:u qrtl'IocioN:t:"Ico Lottiw 10 1nuit0 10 m10 6 60 73 71 69 '. 58 70 73 71 54 65 ° 69 ;. 67 ' 2g3-.:87,ag,t4as 46 58 70 89" 38 51 62 62 C .% M4 .844.242.A44 - 29 41 40 76 76 70 70 6.3 6.3 6.3 6.3 60 73 70 70 53 66 :.70;: " 70 46 58 69 70 " 39 51 62 62 31 44 55 55 - 36 48 48 - 29 40 40 44 56 70 7 37 49 63 64 - 28 42 43 75 69 69 6.3 6.3 6.3 58 70 69 '' 69 51 64 69 _ 69 44 68 68 37 50 61 61 30 43 54 54 - 36 47 47 - 29 40 40 41 53 66 67 >= 35 47 60 61 - 28 41 42 73 73 67 67 6.3 6.3 6.3 6.3 53 65 67 67' 47 59 66 66 41 52 63 63 35 46 57 57 29 40 51 51 - 34 45 45 - 28 38 39 1800 72 67 62 57 74 74 65 63 5.6 5.6 5.4 5.5 50 60 °65 ` . 44 55 ° 65" 39 50 62 83 • 4 trl 28 39 51 5 2 . A4 - 28 41 42 71 71 65 65 6.3 6.3 6.2 6.3 49 59 . "_ ' '65 •'BS ' 43 54 63 63 38 48 58 58 33 43 53 53 27 38 47 47 - 32 42 42 - 27 37 37 - Air On Evaporator Coll Temperature of Air on Condenser Coil 105 °F 115 °F Total Cap. MBH Powe Input KW Sensible Capac ty MBH Total Cap. MBH Powe Input' KW Sensible Capacity MBH CFM M IB F Entering Dry Bulb. °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 8 0 77 74 7 1 68 2700 72 67 62 57 76 71 64 64 7qg NNNN 61 70 84 < ='84 ' 224 S 45 58 64 > %.'64`% , 38 50 56 56 1 2444 - 35 41 41 - 27 34 34 75 65 57 57 7.9 7.8 7.8 7.7 59 - ;65: 61 i 57 G s*4 43 56 57: a�7 2422 28 41 42 42 - 33 34 34 - 25 27 27 2550 72 67 62 57 76 71 64 64 0 0 NNNN 59 69 .. °' 64 84" 51 64 04 64 44 58 , 84 e84 -' 37 49 56 56 M444 .X44 - 27 35 34 76 86 58 58 7.9 7.9 7.8 7.7 57 :.66': 56, ' 68``` 4;34 4141 35 47 50 27 40 43 43 - 32 36 36 - 25 29 29 2400 72 67 62 57 75 70 64 64 56 68 x 84 44344 43 54 63 63 36 48 56 56 29 41 49 49 .A44 - 27 35 35 76 66 59 59 8.0 7.9 7.8 7.7 tt44 4,TX ;I: L142 1 142 G 1 U44 - 32 38 37 - 25 31 30 2100 72 67 62 57 73 68 61 61 77qc! NNNN 52 63 481: •- Ayr, 39 50 58 58 • NN 411.0 i:1244 .g44 - 26 34 34 73 63 56 56 7.9 7.8 7.7 7.7 2;34 g?f. 4144 37 48 54 53 31 42 48 47 25 36 42 41 - 30 35 35 - 24 29 29 1800 72 67 62 70 65 59 7.1 7.0 7.0 - . 47 57 59 1 41 51 58 36 46 54 31 41 48 25 35 43 - 25 32 69 60 53 7.8 7.8 7.7 424 444 14441 23 33 39 38 - 28 33 33 - 23 28 27 COOLING CAPACITIES - 6 TON (DHB / DUC072) 530.18 -TG1 1 Those especial are pose neaps. Few net awn*, dhYwnine Ws KW of be apply air blower motor ken the Blower Performance Tibia, mull* ttis blue by 3.415 MBH / KW b clubmen, be motor twat, end deduct Ma heat from the pose copeclty d the unit. 2 These singe Include Is COMINeaaor and Vie oadsnsar fn mobs but not be away air btowa mobs The total condenses bn motor power Input Is 0.38 KW. Refer to the Blowier Palominos Table err the KW of tlw apply air blower motor. Unitary Products Group NOMINAL RATING AU. SENSIBLE CAPACITY 7 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG" 0.20 0.30 0.40 0.50 0.60 0.70 0.80 R M Watts RPM Watts RPM Watts , RPM Watts RPM Watts RPM Watts RPM Watts_ - 036 1700 835 705 880 745 923 795 969 860 1013 970 - - - 1600 811 655 854 695 898 740 942 790 986 840 1029 900 - - 1500 782 610 827 650 871 685 917 730 960 775 1003 825 1046 905 1400 - - 798 595 844 640 889 680 932 720 975 765 1018 790 1300 - - - - 816 590 862 635 907 675 951 715 995 750 1200 - - - - - - 834 585 881 630 927 665 970 705 1100 - - - - - - 809 550 855 590 900 625 942 665 1000 - - - - - - 782 510 829 545 872 858 919 625 900 900 936 615 980 645 1020 660 1050 797 500 843 540 890 580 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG" 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM . Watts RPM Watts RPM Watts RPM Watts RPM Watts 036 1700 - - - - - - - - - - - - - - 1600 - - - - - - - - - - - 1125 - - 1500 - - - - - - - - - - - - - - 1400 1055 875 - - - - - - - - - 970 - - 1300 1036 780 1066 850 - - - - - - - - - - 1200 1011 735 1047 765 1075 800 842 - - - - - - - 1100 987 690 1028 720 1060 750 1084 775 - - - - - - 1000 963 655 1005 680 1040 695 1068 715 1089 735 - - - - 900 936 615 980 645 1020 660 1050 670 1053 680 1090 690 916 730 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG" 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Was RPM Watts RPM Watts RPM Watts' 048 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 745 881 815 920 900 961 970 1001 1030 1600 - - - - 818 665 858 740 898 820 940 890 980 950 1500 - - - - - - 842 695 882 755 922 835 962 895 1400 - - - - - - 833 650 867 705 904 765 942 820 1300 - - - - - - - - 858 665 893 725 932 785 1200 - - - - - - - - 847 640 880 680 916 730 MODEL AIR FLOW CFM Available External Static Pressure - IWG" 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Watts R_P 1 _Malts RPM Watts RPM - Watts - RPM - Watts - — DUC 048 _ 2000 1103 1270 - - - - - - - - 1900 1085 1210 - - - - - - - - - - - - 1800 1064 1145 1102 1180 - - - - - - - - - - 1700 1040 1075 1081 1115 1121 1140 - - - - - - - - 1600 1020 1005 1060 1050 1100 1085 - - - - - - - - 1500 1003 945 1044 995 1088 1035 - - - - - - - 1400 982 880 1024 920 1067 965 1107 1000 - - - - - - 1300 970 835 1010 870 1053 920 1099 960 - - - - - - 1200 953 780 992 815 1034 855 1080 905 - - - - - l 530.18 -TG 1 SUPPLY AIR BLOWER PERFORMANCE - DUCO36 & 048 with Belt -Drive DUCO36 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS)_ NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. * INCLUDES ALLOWANCES FOR AWET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. DUC048 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. "INCLUDES ALLOWANCES FOR AWET EVAPORATOR 0014 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. 8 Unitary Products Group MODEL M OD DUC AIR FLOW CFM Available External Static Pressure - IWG' 0.20 0.30 0.40 0.50 0.60 0.70 0.80 eV Watts 1560 RPM 1077 Watts 1590 RPM 1095 Watts 1630 RPM 1114 Watts 1650 RPM 1134 Watts 1660 RPM 1158 Watts 1685 RPM 1181 Watts 1720 060 2500 1059 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 2200 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 2100 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 2000 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 1900 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 1800 - - - - 855 815 903 860 950 905 988 940 1022 970 1700 - - - - - • 884 815 925 850 964 880 1001 910 1600 - - - - - - 864 770 908 805 948 835 987 870 1500 _1500 1004 860 1038 880 1070 925 1101 882 740 926 780 965 830 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG' 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM _Watts RPM - Watts - RPM - Watts - RPM - Watts - RPM - WattRPM - - Watts - RPM - Watts - 060 GIMNIP 2500 - - 2400 1193 1665 - - - - - - - - - - - - 2300 1170 1580 1202 1620 - - - - - - - - - - 2200 1148 1480 1180 1530 - - - - - - - - - 1425 2100 1121 1385 1155 1425 1190 1475 - - - - - - - - 2000 1100 1285 1133 1340 1169 1385 1205 1445 - - - - - - 1900 1079 1180 1110 1240 1143 1280 1178 1330 1222 1375 - - • - 1800 1058 1060 1090 1135 1122 1190 1158 1240 1196 1295 - - - - 1700 1035 980 1071 1030 1103 1100 1134 1140 1164 1175 1197 1205 - - 1600 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 1198 1150 _1500 1004 860 1038 880 1070 925 1101 980 1130 1045 1J58 1075. 1184 1110 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 ►' 1I 1i ' : 1..1_ : 1:1 : A.U. : ' u A ?l : :.1. :'u 1? 072 3200 1150 2325 1182 2425 1212 2525 - - - - - - - - 3000 1100 2010 1129 2090 1157 2150 1185 2225 1215 2290 1242 2360 - - 2800 1045 1700 1074 1780 1102 1850 1131 1940 1160 2025 1190 2075 1217 2130 2600 985 1425 1015 1475 1045 1540 1075 1630 1103 1715 1135 1760 1163 1825 2400 930 1240 958 1300 990 1350 1020 1400 1051 1430 1081 1490 1111 1600 2200 - - 905 1070 933 1160 965 1210 997 1250 1028 1285 1060 1325 2000 - - - - - - - 919 1025 950 1100 982 1130 1014 1160 18.0 - - - - - - 1087 - 909 925 939 1005 968 1030 MODEL DUC AIR FLOW CFM Available External Static Pressure - IWG' 0.90 1.00 1.10 1.20 1.30 1.40 1.50 :'t L I. :' 1 A4l :' fll :' i A.1. 'Pil A r..i :P14 il' Vu A :1 072 3200 - - - - - - - - - - - - - - 3000 - - - - - - - - - - - - - - 2800 1245 2190 - - - - - - - - - - - - 2600 1193 1920 1222 1990 1250 2060 - - - - - - - - 2400 1142 1675 1173 1730 1205 1800 1234 1885 - - • - - - 2200 1090 1380 1124 1450 1155 1550 1186 1640 1217 1710 1249 1775 - - 2000 1045 1175 1077 1200 1109 1275 1140 1360 1170 1460 1205 1545 1235 1600 1800 998 1 50 1028 1060 1058 1060 1087 1075 1118 1150 1148 1250 _ 1176 , 1360 SUPPLY AIR BLOWER PERFORMANCE - DUC060 & 072 with Belt -Drive DUC060 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS 530.18 -TG 1 NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. 'INCLUDES ALLOWANCES FOn A WET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. DUC072 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. 'INCLUDES ALLOWANCES FOR AWET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. Unitary Products Group 9 530.18 -TG 1 SUPPLY AIR BLOWER PERFORMANCE - DUCO36, 048, 060, 072 with Direct -Drive GAS HEAT 230/460/575 VOLTS -Side Duct Applications NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. * INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. FACTORY-INSTALLED OPTION BELT DRIVE BLOWER: Adjustable belt -drive blower, providing maximum flexibility to handle many airflow requirements, is available on 5 ton, single and 3 -phase models, and 6 ton, 3 -phase models. FIELD - INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes a slide -in / plug -in damper assembly with fully modulating spring retum motor actuator capable of introducing up to 100% outdoor air, one outdoor air electronic enthalpy sensor and a rain hood with filters. The rain hood is painted to match the basic unit and must be field- assembled before installation. Economizer dampers are 2% low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes the same damper system and rain hood with filters as described for a single enthalpy economizer except this accessory contains two enthalpy sensors. It uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED AIR DAMPER - Includes a slid -in /plug -In damper assembly with a rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. The damper is capable of providing 0% through 100% of outdoor return air opening. MANUAL OUTDOOR DAMPER - Provides 0% through 35% or 0% through 100% of retum air opening (field adjustable). Designed for duct mounted side or bottom supply /return applications. Includes rain hood assembly and filter. ELECTRIC HEATERS - Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities from 5 KW thru 30 KW heating are available. FUSE BLOCK KITS - These kits have a fuse box with a fuse block and fuses. They're available for all 460-3-60 volt heaters and 208/230 -3-60 volt heaters 7 KW and smaller. OUTDOOR THERMOSTAT - A24 -volt thermostat providing two stages of control for units equipped with electric heat accessories. 10 ROOF CURB - This 14" high full perimeter roof curb is shipped knocked down for field assembly and contains duct supports that can easily be shifted for the desired unit duct arrangement. No insulated deck is required because the unit underside Is insulated. START ASSIST KIT - Provides increased starting torque for single phase units in areas with low voltage conditions. It contains a 12.5 OHM PTCR temperature resistor with a support clip and hardware for mounting. LOW AMBIENT KIT Alow ambient controller maintains stable system operation by reducing the speed of the condenser fan motor when the outdoor temperature is between 45 and 0°F. ANTI - RECYCLE TIMER - A timer to prevent the units scroll compressor from short cycling. It assures a 5- minute off -time between compressor cycles. PROPANE CONVERSION KIT - Converts a gas -fired heater from natural gas to propane. It contains main burner orifices, a pilot orifice and a regulator spring. LOW NOx KIT (natural gas furnaces only) - Contains five stainless steel expanded metal sheets for mounting into the heat exchanger tubes to meet the California low nitrous oxide emission requirements. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) - Provides orifices for proper furnace operation at altitudes up to 6000 feet. For propane applications, the propane conversion kit will also be required. GAS PIPING - This kit contains 1/2' pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut -off. OUTDOOR COIL GUARD - Consists of grille -type sections for installation over the outdoor coil to protect it from damage. WALL THERMOSTAT The units are designed to operate with 24 -volt electronic and electro- mechanical thermostats. All units can operate with single stage heat / single stage cool thermostats - with or without the economizer. Unitary Products Group Available External Static Pressure - IWG* MODEL MOTOR 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 DUC SPEED CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts CFM Watts HI - - - - 1699 825 1650 785 1570 755 1430 725 1360 1280 680 1180 036 MED 1684 800 1631 780 1582 750 1524 720 1410 690 1324 650 1260 cD �o 1185 610 1100 LOW 1487 710 1464 690 1421 670 1367 650 1315 620 1246 605 1185 1110 570 1020 HI 1996 960 1933 936 1868 910 1795 880 1722 845 1635 820 790 1419 765 1300 740 048 MED 1804 838 1765 810 1714 785 1650 765 1589 735 1508 705 675 1306 645 1195 625 LOW 1681 760 1640 738 1604 715 1541 695 1490 670 1416 645 620 1230 595 1120 575 HI 2400 1155 2338 1125 2274 1095 2167 1045 2096 1010 1990 980 1887 1771 cg q 1629 855 060 MED 2290 1105 2214 1065 2145 1030 2071 990 1990 950 1911 920 1828 E 1724 1604 798 LOW 2150 1020 2100 990 2029 950 1965 910 1905 880 1816 838 1724 1644 1531 710 072 HI 2461 1480 2402 1440 2361 1395 2260 1350 2178 1305 2101 1260 2000 1205 1914 1155 1830 1110 530.18 -TG 1 SUPPLY AIR BLOWER PERFORMANCE - DUCO36, 048, 060, 072 with Direct -Drive GAS HEAT 230/460/575 VOLTS -Side Duct Applications NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. * INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. FACTORY-INSTALLED OPTION BELT DRIVE BLOWER: Adjustable belt -drive blower, providing maximum flexibility to handle many airflow requirements, is available on 5 ton, single and 3 -phase models, and 6 ton, 3 -phase models. FIELD - INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes a slide -in / plug -in damper assembly with fully modulating spring retum motor actuator capable of introducing up to 100% outdoor air, one outdoor air electronic enthalpy sensor and a rain hood with filters. The rain hood is painted to match the basic unit and must be field- assembled before installation. Economizer dampers are 2% low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes the same damper system and rain hood with filters as described for a single enthalpy economizer except this accessory contains two enthalpy sensors. It uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED AIR DAMPER - Includes a slid -in /plug -In damper assembly with a rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. The damper is capable of providing 0% through 100% of outdoor return air opening. MANUAL OUTDOOR DAMPER - Provides 0% through 35% or 0% through 100% of retum air opening (field adjustable). Designed for duct mounted side or bottom supply /return applications. Includes rain hood assembly and filter. ELECTRIC HEATERS - Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities from 5 KW thru 30 KW heating are available. FUSE BLOCK KITS - These kits have a fuse box with a fuse block and fuses. They're available for all 460-3-60 volt heaters and 208/230 -3-60 volt heaters 7 KW and smaller. OUTDOOR THERMOSTAT - A24 -volt thermostat providing two stages of control for units equipped with electric heat accessories. 10 ROOF CURB - This 14" high full perimeter roof curb is shipped knocked down for field assembly and contains duct supports that can easily be shifted for the desired unit duct arrangement. No insulated deck is required because the unit underside Is insulated. START ASSIST KIT - Provides increased starting torque for single phase units in areas with low voltage conditions. It contains a 12.5 OHM PTCR temperature resistor with a support clip and hardware for mounting. LOW AMBIENT KIT Alow ambient controller maintains stable system operation by reducing the speed of the condenser fan motor when the outdoor temperature is between 45 and 0°F. ANTI - RECYCLE TIMER - A timer to prevent the units scroll compressor from short cycling. It assures a 5- minute off -time between compressor cycles. PROPANE CONVERSION KIT - Converts a gas -fired heater from natural gas to propane. It contains main burner orifices, a pilot orifice and a regulator spring. LOW NOx KIT (natural gas furnaces only) - Contains five stainless steel expanded metal sheets for mounting into the heat exchanger tubes to meet the California low nitrous oxide emission requirements. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) - Provides orifices for proper furnace operation at altitudes up to 6000 feet. For propane applications, the propane conversion kit will also be required. GAS PIPING - This kit contains 1/2' pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut -off. OUTDOOR COIL GUARD - Consists of grille -type sections for installation over the outdoor coil to protect it from damage. WALL THERMOSTAT The units are designed to operate with 24 -volt electronic and electro- mechanical thermostats. All units can operate with single stage heat / single stage cool thermostats - with or without the economizer. Unitary Products Group DESCRIPTION RESISTANCE, IWG CFM 1000 1200 1400 1600 18 00 2000 2200 2400 2600.2800 0.23 0.26 L 3000 0.30 Economizer" 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 Electric Heaters 5-15 KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20 - 30 KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 020 0.23 0.26 Bottom Duct Connectiona 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 0.19 0.22 Coolirio Onlv 0.08 0.10 0.12 0.14 0.18 _9.18 0.20 0.23 0.26 9.29 0.32 MOTOR AND DRIVE DATA - Belt -Drive Blower MODEL BLOWER RANGE (RPM) MOTOR* ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT HP RPM FRAME SIZE SERVICE FACTOR PITCH DIA. (In.) BORE (in) PITCH DIA (In.) BORE (In) PITCH LENGTH (In.) DESIG- NATION DHB / DUC 036 790 - 1120 1 1725 56 1.15 2.4 - 3.4 7 /8 5.7 1 37.3 A36 DHB / DUC 048 790 - 1120 1 1725 56 1.15 2.4 - 3.4 Ve 5.7 1 37.3 A36 DHB / DUC 060 850 - 1220 1 1725 56 1.15 2.4 - 3.4 7 /0 5.2 1 37.3 A36 DHB / DUC 072 _ 900 - 1250 _ 1 1725 56 1.15 2.8 - 3.8 VA 5.2 1 37.3 A36 MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) SCROLL COMPRESSOR COND. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA LRA LRA 208/230-1-60 187 187 18.0 105.0 1.3 4.4 28.2 45 45 036 208/230-3-60 460-3-60 187 414 3 N U) 11.4 6.2 90.0 45.0 1.3 0.8 4.4 2.2 20.0 10.8 30 15 30 15 30 15 575-3-60 518 518 5.0 36.0 0.8 2.2 9.3 15 - - 208/230 -1-60 187 187 24.4 140.0 1.3 5.0 36.8 60 60 048 208/230-3-60 480 -3-60 187 414 � 0 N 10 14.1 7.1 105.0 55.0 1.3 0.8 5.0 2.2 23.9 11.9 35 15 35 15 35 15 575-3-60 518 518 5.6 44.0 0.8 2.2 10.1 15 - - 208/230 -1.60 187 I0 N N10 28.9 165.0 1.3 6.6 44.0 70 70 060 208/230 -3-60 460 -3-60 187 414 16.0 8.0 125.0 67.0 1.3 0.8 6.6 3.3 27.9 14.1 40 20 40 20 40 20 575 -3-60 518 6.4 50.0 0.8 3.3 12.1 15 - - 208/230 -3.60 187 253 20.3 146.0 1.3 6.8 33.5 50 50 072 460-3-60 414 504 10.2 73.0 0.8 3.6 17.2 25 25 25 575 -3-60 518 630 8.2 I 58.4 0.: 4 - CLCU 1 tiltiAL UA IA - basic units witn tieit-unve MODEL DHB DUC POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) SCROLL COMPRESSOR COND. FAN MOTOR, FL A SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA LRA 208/230 -1 -60 187 18.0 105.0 1.3 5.3 29.1 45 45 036 208/230 -3-60 460-3-60 187 414 170 10 N Lo 11.4 6.2 90.0 45.0 1.3 0.8 5.3 3.1 20.9 11.7 30 15 30 15 575-3-60 518 5.0 36.0 0.8 3.1 10.2 15 - 208/230 -1 -60 187 24.4 140.0 1.3 8.6 40.4 60 60 048 208/230-3-60 460-3-60 187 414 in 0 N 1A 14.1 7.1 105.0 55.0 1.3 0.8 5.2 2.6 24.1 12.3 35 15 35 15 518 5.6 44.0 0.8 2.0 9.9 15 - 208/230-1-60 187 �1 N N 10 CO 28.9 165.0 1.3 8.6 48.0 70 70 060 208/230-3-60 460-3-60 187 414 16.0 8.0 125.0 67.0 1.3 0.8 6.0 3.0 27.3 13.8 40 20 40 20 575-3-60 518 6.4 50.0 0.8 2.4 11.2 15 - 208/230 -3-60 187 253 20.3 146.0 1.3 7.3 34.0 50 50 072 460 -3-60 414 504 10.2 73,0 0.8 3.7 17.3 25 25 • STATIC RESISTANCES 1 Deduct these resistance values from the available external static pressure shown In the respect." Blow Performance TWIG. 2 Add these resistance values lo the available static resistance in the respect vs Bower Performance Table. "The pressure hnl th economizer Is greater for 100% outdoor air than for 100% return dr. If the resistance of the return sir duct system Is less hen 0.25 IWO, the unit wile deliver less CFM during fuN economizer opera lion. 'AN moors have solid bases and are krharendy protected These motors an be estscted to operate kilo heir seMoe factor because they are located In he riming dr, upstream of any heating device. ELECTRICAL DATA - Basic Units with Direct -Drive NOTES: 1. Utilization Range W In accordance with ARI Standard 110. 2. Dual element, time delay type, • 530.18 -TG1 NOTES: 1. Utilization Range A• in socordnos with ARI Standard 110. Unitary Products Group 2. Dual element, time delay type. 11 ELECTRICAL DATA - Cooling / Electric Heating (DHB036 & 048) with Direct -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MINIMUM CIRCUIT AMPACITY MAX SI AMPS MAX. SIZE HACR2 BREAKER AMPS KW STAGES TOTAL AMPS 2CE04500506 4.0 19.1 29.4 45 45 2CE04500706 5.6 27.1 39.4 45 45 208 -1 -60 2CE04501006 4.4 8.0 38.3 53.3 60 60 2CE04501506 11.9 57.4 77.3 80 80 2CE04502006 15.9 76.6 101.2 110 110 2CE04500506 5.3 33.1 45 45 2CE04500706 7.5 44.6 45 45 230 -1 -60 2CE04501006 4.4 10.6 N 4 60.7 70 70 2CE04501506 15.9 88.3 90 90 2CE04502006 21.2 115.9 125 125 2CE04500525' 4.0 11.0 2CE04500725" 5.6 15.6 036 208 -3 -60 2CE04501025 2CE04501525 4.4 11.9 N 22.1 33.1 t W iO Xi 0 +) 10 Cn 4 0 CT 2CE04502025 15.9 44.2 2CE04500525' 5.3 12.7 2C E04500725" 7.5 18.0 230 -3 -60 2CE04501025 4.4 10.6 25.5 37.4 4. 0 O 0 2CE04501525 15.9 38.2 53.3 2CE04502025 21.2 51.0 69.2 2CE04500746* 6.8 1 8.2 13.0 15 15 2C E04501046* 10.1 1 12.1 17.9 20 20 460-3-60 22 2 ' 2 13.6 1 18.4 23.2 25 25 2CE04502046* 19.5 2 23.5 32.1 35 35 2CE04501058 10.6 1 10.2 15.5 20 - 575-3-60 2CE04501558 2.2 15.9 1 15.3 21.9 25 - 2CE04502058 21.2 2 20.4 28.2 30 - 2CE04500506 4.0 19.1 36.8 60 60 2CE04500706 5.6 27.1 40.1 60 60 208 -1 -60 2CE04501006 5.0 8.0 38.3 54.1 60 60 2CE04501506 11.9 57.4 78.0 80 80 2CE04502006 15.9 76.6 101.9 110 110 2CE04500506 5.3 36.8 60 60 2CE04500706 7.5 45.3 60 60 230 -1 -60 2CE04501006 5.0 10.6 N 4 61.5 70 70 2CE04501506 15.9 89.1 90 90 2CE04502006 21.2 118.7 125 125 2CE04500525" 4.0 23.9 2CE04500725" 5.6 25.8 208-3-60 2CE04501025 5.0 8.0 N N 33.9 LO CO CJ CJ1 048 2CE04501525 11.9 47.7 2CE04502025 15.9 61.5 2CE04500525* 5.3 12.7 23.9 111 to 00 O O V' CO is 2CE04500725" 7.5 18.0 28.8 230 -3 -60 2CE04501025 5.0 10.6 25.5 38.1 O 2CE04501525 15.9 38.2 54.1 2CE04502025 21.2 51.0 70.0 2CE04500746* 6.8 1 8.2 13.0 15 15 2CE04501046" 10.1 1 12.1 17.9 20 20 460 -3.60 2CE04501546" 2 ' 2 13.6 1 16.4 23.2 25 25 2CE04502046* 19.5 2 23.5 32.1 35 35 2CE04501058 10.6 1 10.2 15.5 20 - 575 -3 -60 2CE04501558 2.2 15.9 1 15.3 21.9 25 - 2CE04502058 21.2 2 20.4 28.2 30 - 530.18-TG1 12 1 Dual element, time delay type 2 Standard circuit breakers may be used In Canada and on applications over 60 amps where the heaters are separately fused. • These electric heaters DO NOT Include a fuse box. If a fuse box Is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field Installation. Nominal Voltage Voltage 249 230 460 208 240 480 Electric Heat Correction Factors Fuse Block r 2Fa04700425 I 208240 obits 2FB04700546 - -- 460 Voce KW Cap Muldoler 1.00 0,92 0,92 Unitary Products Group C ELECTRICAL DATA - Cooling Electric Heating (DHB06 with -. t -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY MOTOR ELECTRIC HEATERS -- MAX FUSE AMPS MAX. HACR2 BREAKER KW STAGES AMPS 2CE04500506 4.0 19.1 44.0 70 70 2CE04500706 5.6 27.1 44.0 70 70 208 -1-60 2CE04501006 2CE04501506 8.0 11.9 • N ' 8' 57.4 56 80.0 70 90 70 90 2CE04502006 15.9 76.6 103.9 110 110 20E04503006 22.2 106.9 141.9 150 150 2CE04500506 5.3 22.1 44.0 70 70 2CE04500706 7.5 31.3 47.3 70 70 230-1-60 2CE04501006 2CE04501506 10.6 15.9 r N 44.2 66.3 63.5 91.1 70 100 70 100 2CE04502006 21.2 88.3 118.7 125 125 2CE04503006 29.6 123.3 162.4 175 175 2C E04500525* 4.0 11.0 27.9 2CE04500725* 5.6 15.6 27.9 208-3-60 2CE04501025 8.0 ✓ C 22.1 35 0 C .1 11 . 0 O C vu 060 2CE04501525 2CE04502025 11.9 15.9 33.1 44.2 49.7 63.5 2CE04503025 22.2 61.7 85.4 2C E04500525` 5.3 12.7 27.9 40 2CE04500725* 7.5 18.0 30.8 40 2CE04501025 10.6 25.5 40.1 45 230-3-60 2CE04501525 66 15.9 N 38.2 56.1 O 60 2CE04502025 21.2 51.0 72.0 80 2CE04503025 29.6 71.2 97.3 100 2C E04500746* 6.8 8.2 14.3 2CE04501046* 10.1 12.1 19.3 460 -3 -60 20E04501546* 3.3 13.6 16.4 24.6 CT to 2CE04502046* 19.5 23.5 33.4 2C E04503046'' 28.8 34.6 47.4 2CE04501058 10.6 1 10.2 16.9 20 - 2CE04501558 15.9 1 15.3 23.2 25 - 575-3-60 2CE04502058 3 ' 3 21.2 2 20.4 29.6 30 - 2CE04503058 30.4 2 29.3 40.7 45 - , 2CE04500525* 4.0 11.0 33.5 2CE04500725* 5.6 15.6 33.5 2CE04501025 8.0 22.1 36.1 208-3-60 2CE04501525 68 11.9 N 33.1 49.9 0 O C71 O 2CE04502025 15.9 44.2 63.7 2CE04503025 22.2 61.7 85.6 2CE04500525* 5.3 12.7 33.5 50 2CE04500725* 7.5 18.0 33.5 50 2CE04501025 10.6 25.5 40.4 50 230-3-60 6.8 6.8 15.9 N 38.2 56.3 CA 0 60 072 2CE04502025 21.2 51.0 72.2 80 2CE04503025 29.6 71.2 97.5 100 2C E04500746* 6.8 8.2 17.2 • 01 CJ N N 0010101 01 2C E04501046* 10.1 12.1 19.7 460-3-60 2C E04501546* 3.6 13.6 16.4 24.9 2CE04502046* 19.5 23.5 33.8 2CE04503046* 28.8 34.6 47.8 2CE04501058 10.6 1 10.2 17.2 20 - 2CE04501558 15.9 1 15.3 23.6 25 - 575-3-60 2CE04502058 36 21.2 2 20.4 30.0 30 - 2CE04503058 30.4 2 29.3 41.1 45 - Dual element, time delay type 2 Standard circuit breakers may be used In Canada and on applications over 60 amps where the heaters are separately fused. - These electric heaters DO NOT include a fuse box. If a fuse box Is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field Installation. Unitary Products Group 530.18 -TG 1 Nominal Voltage 208 240 480 Voltage 208 230 480 600 575 0.92 Electric Heat Correction Factors KW Cap Muldaler 1.00 0.82 0.92 Fuse Biotic 1 2F804700425 I 2 Volts 2FB04700546 0 Valts 13 ELECTRICAL DATA - Cooling / Electric Heating (DHB036 & 048) with Belt -Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MINIMUM CIRCUIT AMPACITY MAX. FUS SIZE AMPS MAX. SIZE HACR 2 BREAKER AMPS STAGES Amps 2CE04500506 4.0 19.1 30.5 45 45 2CE04500706 5.6 27.1 40.5 45 45 208 -1 -60 2CE04501006 5.3 8.0 38.3 54.5 60 80 2CE04501506 11.9 57.4 78.4 80 80 2CE04502006 15.9 76.6 102.3 110 110 2CE04500506 5.3 34.2 45 45 2CE04500706 7.5 45.7 50 50 230 -1 -60 2CE04501006 5.3 10.6 N 61.8 70 70 2CE04501506 15.9 f39.4 90 90 2CE04502006 21.2 117.0 125 125 2CE04500525' 4.0 11.0 2CE04500725" 5.6 15.6 036 208 -3-60 2CE04501025 2CE04501525 5.3 11.9 (V 22.1 33.1 tq 0 Col 1.C) U1 41 0 (T 2CE04502025 15.9 44.2 2C E04500525* 5.3 12.7 2CE04500725" 7.5 18.0 230 -3-60 2CE04501025 5.3 10.6 25.5 O O 0 2CE04501525 15.9 38.2 2CE04502025 21.2 51.0 2CE04500746* 6.8 1 8.2 14.1 15 15 460-3-60 2C E04501046* 2C 3.1 3 ' 1 10.1 13.6 1 1 12.1 16.4 19.1 24.3 20 25 20 25 2C E04502046* 19.5 2 23.5 33.2 35 35 2CE04501058 10.6 1 10.2 16.6 20 - 575.3.60 2CE04501558 3.1 15.9 1 15.3 23.0 25 - 2CE04502058 21.2 2 20.4 29.4 30 - 2CE04500506 4.0 19.1 60 60 2CE04500706 5.6 27.1 60 60 208 -1 -60 2CE04501006 8.6 8.0 38.3 (0 2 60 60 2CE04501506 11.9 57.4 90 90 2CE04502006 15.9 76.6 110 110 2CE04500506 5.3 40.4 60 60 2CE04500706 7.5 49.8 60 60 230 -1 -60 2CE04501006 8.6 10.6 N c 66.0 70 70 2CE04501506 15.9 93.6 100 100 2CE04502006 21.2 121.2 125 125 2CE04500525" 4.0 24.1 2CE04500725' 5.6 26.0 208-3-60 2CE04501025 5.2 8.0 N N 34.1 (71 (!t 048 2CE04501525 11.9 47.9 2CE04502025 15.9 61.7 2CE04500525" 5.3 12.7 24.1 6)G)AWC.) 000 CD (71 2CE04500725* 7.5 18.0 29.1 230-3-60 2CE04501025 5.2 10.6 25.5 38.4 O 2CE04501525 15.9 38.2 54.3 2CE04502025 21.2 51.0 702 2C E04500746* 6.8 1 8.2 13.5 15 15 2C E04501046* 10.1 1 12.1 18.4 20 20 460-3-60 2.6 2 ' 6 13.6 1 16.4 23.7 25 25 2CE04502046" 19.5 2 23.5 32.6 35 35 2CE04501058 10.6 1 10.2 15.2 20 - 575.3.60 2CE04501558 2.0 15.9 1 15.3 21.6 25 - 2CE04502058 21.2 2 20.4 28.0 30 - 530.18 -TG1 I Dual element, lime delay type 2 Standard drexult breakers may be used In Canada and on applications over 80 amps where the heaters are separately fused. ' These elecbfc healers DO NOT Include a Nee box. If a fuse box Is required b meet a local code Ogg., Chicago), the lolbwmg Nee block accessories are avMabls for held Installation. 14 Electric Heat Correction Facbrs Fuse Block r� 2F8W700425 I 2118210 Vbks 2FBO47nn648 4 01ldta 230 Nominal Voltage 208 240 480 Voltage 208 KW Cap Muttloler 1.00 0.92 0.92 a- Unitary Products Group rive ELECTRICAL DATA - Cooling Heating (DHB06C ° 072) --- '`h Belt-Drive MODEL DHB POWER SUPPLY HEATER ACCESSORY MODEL NUMBER Si Bt M FLA ELECTRIC HEATERS MAX =USE SIZE' AMPS MAX. HR2 BREAKER AMPS KW STAGES - I�.-.. - 2CE04500506 4.0 19.1 70 70 20E04500706 5.6 27.1 70 70 208.1 -60 2CE04501006 2CE04501506 - - 8.0 11.9 r N 38_3 57.4 m O 70 90 70 90 2CE04502006 15.9 76.6 110 110 2CE04503006 22.2 106.9 150 150 20E04500506 5.3 22.1 70 70 2CE04500706 7.5 31.3 70 70 230 -1 -60 2CE04501006 20E04501506 10.6 15.9 r 44.2 66.3 O p t0 S 70 100 70 100 2CE04502006 21.2 88.3 125 125 2CE04503006 29.6 123.3 175 175 2C E04500525* 4.0 11.0 27.3 2CE04500725' 5.6 15.6 27.3 2CE04501025 8.0 22.1 35.1 208-3-60 2CE04501525 11.9 O O O O 060 2CE04502025 15.9 44.2 62.7 2CE04503025 22.2 61.7 84.6 2CE04500525' 5.3 12.7 27.3 40 40 2CE04500725* 7.5 18.0 30.1 40 40 230 -3-60 2CE04501025 20E04501525 60 6 ' 10.6 15.9 r N 25.5 38.2 39.4 55.3 40 60 40 60 2CE04502025 21.2 51.0 71.2 80 80 2CE04503025 29.6 71.2 96.5 100 100 2CE04500746* 6.8 8.2 14.0 20E04501046' 10.1 12.1 18.9 460-3-60 2CE04501546" 3.0 13.6 16.4 24.2 10 N N N 2CE04502046' 19.5 23.5 33.1 2CE04503046' 28.8 34.6 47.1 2CE04501058 10.6 1 10.2 15.7 20 - 2CE04501558 15.9 1 15.3 22.1 25 - 575 -3-60 20E04502058 2 ' 4 21.2 2 20.4 28.5 30 - 2CE04503058 30.4 2 29.3 39.6 40 - 2CE04500525' 4.0 11.0 2CE04500725' 5.6 15.6 208-3-60 2CE04501025 2CE04501525 7 ' 3 8.0 11.9 r N 22.1 33.1 n m S O O �0 CO O O 10 C0 2CE04502025 15.9 44.2 2CE04503025 22.2 61.7 2CE04500525* 5.3 12.7 50 50 2CE04500725' 7.5 18.0 50 50 230-3-60 2CE04501025 2CE04501525 7 ' 3 10.6 15.9 r N 25.5 38.2 0 . 0 50 60 50 60 072 2CE04502025 21.2 51.0 80 80 2CE04503025 29.6 71.2 100 100 2CE04500746" 6.8 8.2 17.3 tA�D NNN)OJ10 2CE04501046' 10.1 12.1 19.8 460 -3-60 2CE04501546' 3.7 13.6 16.4 25.1 O O 2CE04502046' 19.5 23.5 33.9 2CE04503046' 28.8 34.6 47.9 2CE04501058 10.6 1 10.2 162 20 - 575 -3-60 2CE04501558 2CE04502058 2 ' 8 15.9 21.2 1 2 15.3 20.4 22.6 29.0 25 30 - - 2CE04503058 30.4 2 29.3 40.1 45 - t Dual element Ume delay type 2 Standard circuit breakers may be used In Canada and on applications over GO amps where the healers are eeparaley fused. • These electric heaters DO NOT Indude a fuse box. 11 a fuse box Is required b meet a local code ((eg., Chicago), the Wowing fuse block accessories are available for field Installation. Unitary Products Group Fuse Block 530.18 -TG1 2F804700425 ( 20$240 Volts ZF304700548 480 Volta 15 530.18-TG1 FIELD WIRING i GROUND LUG 16 CONTACTOR COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT' UN T TERMINAL TERMINALS STRIP TB1 L FIELD-SUPPLIED DISCONNECT r I SINGLE I r;' ¢ -r¢ - r- PHASE - --(}'� 0- -L POWER J SUPPLY REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTEC- TION AND WIRING. 24 VOLT TRANSFORMER 1 24 VOLT THERMOSTAT 8TH08701024. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER JI FROM TERMINALS 8 AND 10 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE SCROLL COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOLING, USE THERMOSTAT 8TH04702124. TYPICAL POWER WIRING _ I GROUND L LUG TYPICAL CONTROL WIRING CONTACTOR m '1 e L L. FIELD-SUPPLIED DISCONNECT I THREE r - - -0.r . - ¢ f PHASE . - p.- $ ' O - POWER SUPPLY COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT' TERMINALS ADD JUMPE UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER 1 24 VOLT THERMOSTAT 8TH07700124. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER JI FROM TERMINALS 8 AND 10 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE SCROLL COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOUNG OR HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTATBTH04702024. Unitary Products Group UTILITIES ENTRY DATA HOLE KNOCKOUT SIZE DIA. USED FOR A 7/8" • Control Wiring Side or Bottom •* B 2" " Power Wiring Side or Bottom 0 1 -5/8" Gas Pi.in• Front D 1-1/2" Gas Pi. , Bottom Front DHB Units 24 " DUC Units 32 " Back 12" (Less Economizer) 36" (With Economizer or Fixed Air/Motorized Damper) Left Side (Filter Access) 24" (Less Economizer) 36" (With Economizer) Right Side (Cond. Coll) 24" Below Unit' 0 Above Unit 72" (For Condenser Air Discharge) UNIT DIMENSIONS (DHB AND DUC - 3, 4, 5 & 6 TON) DHB UNITS 3 -6 TON BOTTOM SUPPLY 6 RETURN AIR OPENINGS (SEE NOTE) B - POWER WIRING ENTRY A • CONTROL WIRING ENTRY All dimensions are In Inches. They are subject to change without notice. Certified dimensions will be provided upon request. DUC UNITS 3 -6 TON 34" PVC FEMALE COND. DRAIN (gas Droll •A•) FlELD•SUPPLIED DISCONNECT SWITCH LOCATION (Direct•Ddv. unite) FILTER ACCESS- .92.5/6 7/8 A, ENTRY (8M Detail •B ") BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B • POWER WIRtNO ENTRY A • CONTROL WIRING ENTRY Unitary Products Group CONTROL BCD( ACCESS 4.31 BLOWER ACCESS 32.1/4 UNIT BASE WITH RAIL,a Sham were* b Mistrals baton duct openings end power connection locations. NOTE For ourb•mountod units, Wet b the duct hanger dimensions of the curb nor the proper size of the supply and return dr duct oonnecttonu, VENT NR CUTLET HOOD .r -r3.I it `1..i_iiiiiiiiir c GAS HEAT C � ACCESS / GAS SUPPLY ENTRY 62.11 (W NPTI AT GAS VALVE) / 2•iR 1 4S6 _7 D GAS SUPPLY ENTRY (r /' NPTI AT GAS VALVE) UNIT BASE WITH RAILS Sham secretory to Illustrate bottom duct openings, pow end gas Piping connection realms. NOTE: For curb- mount.d units. tort to the duct hanger dins nslons of the curb lot the props size of the guppy end roam sir duct connections. CONDENSER SCROLL COMPR. ACCESS COMSUST1ON AIR INLET HOOD RELo- rt1ED D 9CONCTSW"CN SLOWER /171001 ACCESS (FSO�R�pd�_ n TLWTCM tZ rnuM�p * me Rowe awswronmS %M . i11r. a•. ttd11 �: i.'!hel:'a1:L �o�d.'.h•, act: n(.:7 "Knockouts In the bottom of the unit can be located by the slice In the Insulation. "Do 0o1 remove the 2' knockout ring. CLEARANCES 1 Units may be Installed on combustible floors made from wood or case A, B or C roof covering material. 2 Units must be Installed oudoors. Overhanging etnubures or shrubs should not obstruct condoner' air discharge outlet NOTES: 01-4111Sac ia: Units and ductwork are approved for zero dear - anCe to combustible materials when equipped with electric heaters. DUC 1500111: A 1' clearance must be provided between any combustible material and the supply sir ductwork for a distance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a confined space and recirculate. Locate unit so that the vent air outlet hood Is at least • Three (3) feet above any forced sir Inlet located within 10 horizontal feel (excluding those Integral to the unit). • Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or gravity sir inlet into the bullring. • Four (4) feet from electric meters, gas meters, regualtors and relief equipment • L 11 Dwarf DOA RETURN AIR SUPPLY AIR 530.18 -TG 1 CONDENSER AIR OUTDOOR AIR (Economizer) 17 530.18-TG1 UNIT DIMENSIONS - CONT'D. (DHB and DUC - 3, 4, 5 & 6 TON) ' i !i -- �' . 11th • � I . I 171/2 \\ i r REAR VIEW 692 SIDE SUPPLY AND RETURN AIR DUCT OPENINGS REAR VIEW REAR VIEW UNIT BASE INSULATION UNIT AND CURB APPUCATION 18 172 I O O o are X 1.114' WIDE OASKETINO FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES 7 271 I 16/81-- -_ • 2 1 i t ii CURB FRAME- WOOD NAILER 14' ��I 6' MIN. ABOVE FINISHED ROOF — mom, f ___J 11V DETAIL "A" UNIT WITH ECONOMIZER RAINHOOD 1 ---271/2 71/4 O O I UNIT BASE RAILS COUNTERFLASHINO CANT STRIP INSULATION AND ROOFINO MATERIAL ROOF DECK AND SUPPORT STRUCTURE DUCT COVERS - Units are shipped with all alr duct openings covered. For side duct applications; 1.Remove and discard the supply and retum air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For tam duct applications; 1. Remove the side supply air duct cover to gain access to the bottom supply alr knockout panel. 2. Remove and discard the bottom knockout panel. 3. Replace the side duct cover. 4. With fitter section access panel removed from the unit, remove and discard the bottom return air knockout panel. 5. Replace the filter access panel. 44% DETAIL "B" L.H. END VIEW UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD DIMENSION 'A' FIXED OUTDOOR 12 AIR DAMPER MOTORIZED DAMPER 161 Unitary Products Group BASIC UNIT OPTIONS /ACCESSORIES DCG SIZE (heat) UNIT WEIGHT' (Ibs.) CORNER WEIGHTS' (location, Ibs) DCE UNIT WEIGHT" (Ibs.) CORNER WEIGHTS' (location, Ibs) DESCRIPTION WEIGHT (Ibs.) "A" N "C" "D" NAN "B" "C" "D" 036 (40 Mbh) 625 180 172 133 140 036 565 160 157 123 125 ECONIMIZER 50 036 (79 Mbh) 635 180 177 138 140 048 615 173 170 135 137 MOTORIZED OUTDOOR AIR DAMPER 26 048 (60 Mbh) 675 193 185 145 152 060 640 180 177 140 143 048 (99 Mbh) 685 193 190 150 152 072 720 171 196 189 164 ELECTRIC ( OrA DCE only KW 18 060 (79 Mbh) 700 200 192 150 158 • Welpht • Unit + Economizer. CORNER 'D' 1 5 Kw 23 (99 O M h) 710 200 197 155 158 2 28 (79 Mbh) 775 186 209 201 179 ROOF 92 072 (99 Mbh) 785 186 214 206 179 REUEF/FIXED AIR DAMPER 10 BELT-DRIVE BLOWER 5 ROOF CURB DIMENSIONS - (DHB and DUC - 3, 4, 5 & 6 TON) DIM. Y X 19-1P2" 37=1/4" DUCT SIZES: Supply oak= 19' x 19' Return Mr. 19' x 19' COMPONENT WEIGHTS AND CENTER OF GRAVITY Unitary Products Group RETURN' AIR CORNER 'A' 3 -5 TON 19 -3/4" 40 -3/4" 6 TON 2 2" L AA" BACK OF UNIT SUPPLY' AIR 44 DUCT SUPPORT RAILS APPROXIMATE CENTER OF GRAVITY FRONT OF UNIT 2• TYP. CORNER 'Supply and Return Air (Including duct support rails) shown ere typical for bottom duct applications. For location of hdtkattlal duct applications (on back of unit), refer to Unit Dimension details. BACK OF UNIT 62 Y SCROLL COMPRESSOR AND CONDENSER END OF UNIT FRONT OF UNIT CORNER 'C' OONDENSER COIL END OF UNIT 530.18 -TG1 19 TYPICAL APPLICATIONS 20&230.1.60 VOLT MODELS ONLY FIELD- SUPPLIED DISCONNECT SWITCH EFFICIENCY RATING CERTIFIED ama IRE Heating • Air Conditioning CONTROL WIRING TO TOWER TO INDOOR SUPPLY THERMOSTAT ROOF JACK INSTALLATION i TYPICAL ROOF -TOP INSTALLATION (MODEL DUC SHOWN) RETURN AIR DUCT SUPPLY AIR DUCT ROOF CURB ROOF CURB / INSTALLATION e' . : r"wM1s LISTED Code: EBL RPC 4M 898 1.10 Supersedes: 30.18•TGIL (397) Subject to change without notice. Printed In U.S.A. Copyright ® by Unitary Products Group 1998, All rights reserved. MANUAL GAS SHUT-OFF VALVE TO GAS SUPPLY LINE SLAB ON GROUND INSTALLATION ISO 9001 OS11T1/r10 530.18•TGI L Unitary Products Group 745 Industrial Parkway Elyria, OH, 44035 ACTIVITY NUMBER: M99 -0251 PROJECT NAME: AMERICAN TELEPHONE : XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DEPARTMENTS: Building Division Public n Pu lic Works PERMIT COORD COP. PLAN REVIEW ROU ING SLIP w Fire Prevention 41 c. 12--11 Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Approved \PKROUTC,DOC 5/99 Incomplete TUES /THURS ROUT NG: Please Route Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved with Conditions REVIEWER'S INITIALS: REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved Approved with Conditions n Revision # , After Permit Is Issued n DATE: • 12- 17 - 99 :- Planning Division Permit Coordinator n or DUE DATE: 12 -21 -99 Not Applicable n Comments: n No further Review Required DATE: DUE DATE 1-18-2000 Not Approved (attach comments) r DATE: DUE DATE Not Approved (attach comments) U REVIEWER'S INITIALS: DATE: City of Tukwila Fire Department Fire Department Review Control #M99 -0251 (510) December 21, 1999 Thomas P. Keefe, Ftre Chief Re: American Telephone - 12658 Interurban Avenue South Dear Sir: The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire.Prevention Bureau. No work shall commence until a fire department permit has been John W. Rants, Mayor LJ.....l......�i.,.... f a..�l..... AAA A C....• - T..L...IL. TAl .J,L..ti.,., 11171 OD DL....... M/1A1 t,r AAAI - C.,... /O/Ltl £'7r AA7/1 Fire Department Page number 2 obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 2.. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, C, City of Tukwila The Tukwila Fire Prevention Bureau cc: TFD file ncd 51� I° ._ ..- _ ii • — n —_ -'- ^ - -. _ .n--r. —..,,_ ri,__L,__.__ 110f 00 — fL____ MALI Pow 44A _ John W. Rants, Mayor Thomas P. Keefe, Fire Chief MALI rofr 4400 DERTM OF LABOR AND INDUSTRIES REGISTERED AS PROVSDED BY 1:.A.. W AS • CO CONT ' GENERAL • art %i ; '�'t� , ` `; � �j E .G �uTr:'�'>7� i l` t • _;ced ,�;�Lil�ixT �sr �6 ; /31 . I , .EF.F CT�IVE W.g— • r ,4 >� . 4 1 , ,..I. M ;.:E— ;r =�., u ;,::IVjtyr :ris . i a::, t. / ,l•2 �..0 2 J,s1 3 UNITED •SYSTEM: S.INC ..: 1021 SW KLICKITAT WY. STE .4.04 SEATTLE .WA : 981 34. :�. ?;''' My commission expires: 1/29/00 Detach And Display Certificate Notary Public residing 4 the State of Washington, County of King • State of Washington County of King X hereby certify, that this is a copy of a valid Contractors Registration document issued by the Department of Labor and industries to United Systems, Inc. Witness my hand and official seal in King County, State of Washington on the day of . A/oa.e:2rlf3r... ;1997 5)‹ OPFIGE oPEI4 slFFICE �om Wore 5EE STR c- TLRhL. veTAML FOR 9200E TOP i-M4C. u{.JIT SuPPoQT, 12"0 EX, OFFICE, cX, OPPice ex, STt1I, c∎ F!GB sX. NExAt OFFICE EX, OF'F€G !*x, OFFIC.ar EQU I P M51,1Y ,SCf EbUI4 AC I LUXAIRE MO L RLIC.04SIJ.1ZS , 4: COOLi11G PAGtTY 1 1 , SEMI' io.0 , . 1600 C f NATURAL G HE. AS 1 H las 1 14 M8M OL'l,T, SOT A uE, 2af /Z30V, o, w-4 44 .. AMPS, - MAX, Ft15E TER1.1O5TAT, ffDNEY1.1E1L T7300'7 -1,AY PRO&RAMMABLe WITH NIGHT Sallit CK; FILE COPY th Plan Ctu • , crro7a tnd' omissions c not authorize life Wolation r • Coda or a3liph. ploNpt': of cc _ctdi' • ap 3o q g • „. • liqq-DD51 SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL C'ELECTRIC AL' ❑ PLUMBING. LJ GA$ PIPING, . c Tv OF iul€LNILA BULDENG DIV!$ION