HomeMy WebLinkAboutPermit M99-0257 - CITY OF TUKWILA - FOSTER GOLF CREW SHOPFOSTER GOLF CREW SHOP M99 -0257 City of Tukwila( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188. Permit No: M99 -0257 Type: B -MECH Category: NRES Address: 14000 INTERURBAN AV S Location: MAINTENANCE FACILITY Parcel #: 336590 -0925 Contractor License No: DESIGL *212DG MECHANICAL PERMIT TENANT FOSTER GOLF COURSE CREW SHOP Phone: 13500 INTERURBAN AV 5, TUKWILA, WA 98188 OWNER CITY OF TUKWILA 6200 SOUTHCENTER BLVD, TUKWILA WA 98188 CONTACT GINGER IMEL Phone: 253 -854 -2770 801 N CENTRAL,-KENT, WA 98032 CONTRACTOR DESIGN AIR, LTD. Phone: 206 854 -2770 801 NORTH CENTRAL, KENT, WA 98032' ***** * * *•k * *** * * *** * *.* * * * *. * * *** *•k *** * *** *** ** * * ** * **•k k ** * ** * * * ** ** *** * * **** Permit Description: PROVIDE /INSTALL HVAC EQUIPMENT & DUCTWORK AS SHOWN ON PLANS. (206) 431 -3670 Status: ISSUED Issued: 02/08/2000 Expires: 08/06/2000 UMC Edition: 1997 Valuation: 25,000.00 Total Permit Fee: 162.00 *'k•k* * * * ** **'k* *•k • **********************k*********************** Permit Center Authorized Signature Date I hereby certify that I have read and examined this permit arid know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work.: I am authorized to sign for and obtain this bu'.,ing pe mit./ "� Signature: C -- `l! �v Date: Z- f OO afx(4zE.72.!. 42:4*& Print Name: 2-8- 000 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 14000 INTERURBAN AV S Suite: Tenant: FOSTER GOLF COURSE CREW SHOP Type: B-MECH , Parcel #: 336590-0925 AA4kk*Akkl.k**A Permit Conditions: 3. Plumbing permits shall be obtained through the Seattle-King County Department of Public HPalth.. Rtymbing will •be inspected by that agendyinc1isdihg,01"'gas piping (296-4722). 2. Electrical permits shaltbe',obtained through the Washington State Division of Labor and Industries and all electrical work will be,inspected'by'that agency (248-:.7 3. No changes will be Made to the plans unless approved by the Engineer, and the Tukwila 'Building Division, 4. All permits,'inspection records, And approved plans" shall be available at the Job site prior to the start of 'any Con- struction. These documents are to be maintained and avail-, ablq inspection is granted: 5. All 'construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition). as amended Uniformlechanical Code (1997,Edition) ,:, and Washington State EnergY'Coder(1997 Edition), 6. Validity of Perait. The issuance a germit or abprOval plans, specifications, and,coliwutati'ons shall not be con- strued to be a permit for, or an approval of, any violation ; of any of the provisions of the bUilding,00de or of any other ordinance of thejurisdictiOn. No,permit presuming to give authority to violate or cancel theforciVisionsof' code shall be valid. 7. Manufacturers tnstallation Instruction On,site for the building inspectors review. ; CITY OF TUKWILA Permit No M99-0257 Status: ISSUED Applied: 12/28/1999 Issued: 02/08/2000 Project Name/Tenant: / � ' .-� cosret- v0t, M�lii l• Ft�IL-ITY Value of nstruction: 4P ,2s,t,e)o Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ii no Attach list of materials and storage location on separate 8 1/2 X 11 •a • er indicatin. • uantities & Material Safet Data Sheets Site Address: City State /Zip: 14 ooc7 L eJTEet.(� �►4� �4 J� . S . C44(-4 f (--� Tax P3`Zlpmb ,��Q Crd1 Propeq Owner: Pho e: Street Address: �p 2 ou TE-4 GS►J rge- & (p . City State /Z,ip 7 4t c) / U4 q 87 6 (cps l44C% ) Fax #: : ) 8 . 5 er . z 7 7a City /State /Zip: Contact Person: /-1 G 1 LI e -i (� . 11 Street Address: l �� I t`f . ►J'�Q F� 1, City State /Zip: (673Z— Fax It: C 25'3 8' 5 - G, 1 3 1 0 Standby Contractor: 17 (C 3r.) Ai P_ Phone: � ZS`3 ) 85 - - Z7 70 Street Address:, ,-, got t V • (..r.) City State/Zip: : . e - A y 1 ax #: 5 ) g5 - l= ( ( Architect: ''" �, / vttr✓7 S5oe • re: Svt S - boa a Street Address: City State /Zip: : Engineer: F • P one: 24 ( - 262! 2— Street Address: City State /Zip: ax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BYAPPLIQANT) . Description of work to be done: ms s• • a m I e-- j . 'II V. __ .: 4 P44 : 5, rL4) bf ° L14/ 6S Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ii no Attach list of materials and storage location on separate 8 1/2 X 11 •a • er indicatin. • uantities & Material Safet Data Sheets Above Ground Tanks (]Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition El Fence ❑ Mechanical ❑ Manufactured Housing- Replacement only El Parking Lots El Retaining Walls El Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF T( - VWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT. REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS Channelization /Striping Flood Control Zone Landscape Irrigation Storm Drainage Water Meter /Exempt ft ❑ Water Meter /Permanent it El Water Meter Temp # ❑ Miscellaneous El El ❑ ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing El Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public Size(s): 0 Deduct 0 Water Only Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load /Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Phone: Address: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date Iplioneptedg Dat appilcation expires: Applicaticp4aken by: (initials) 0 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Suppoited directly upon grade exceeding 5,000 gallons and a ratio of height to diameter . or width which exceeds 2:1 PERMIT REVIEW Submit checklist No:' M -9 • 0 Antennas /Satellite Dishes Submit checklist . No: M -1 0 Awnings /Canopies - No signage Commercial Tenant Improvement Permit Address: 6C9/ /4 e& Bulkhead /Dock • Submit checklist : No M -10 <, 0 Commercial Reroof Submit checklist: No: M -6 El Demolition S No: M-3; M -3a 0 Fences - Over 6 feet in Height , Submit aheckiist NO: M -9 Land Altering/Grading /Preloads Submit checklist . No: M=2 J Loading Docks Commercial Tenant Improvement Permit.. S ubmit checklist: No: H -1.7 Mechanical (Residential & Commercial) Submit checklist No M -8, Residential. only - H -6, H -16 . . El Miscellaneous Public Works Permits Submit checklist No H -9 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M - 5 0 Moving Oversized Load /Hauling ' Submit checklist No: M -5' J Parking Lots Submit checklist No: M -4 El Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 0 Retaining Walls - Over 4 feet in height Submit checklist . No: M -1 Temporary Facilities Submit checklist No: M -7 Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 0 Tree Cutting Submit checklist No: M -2 BUILDING O R OR AUT ORIZED ENT: Signature: t , I' J Date: /2 - 2 F f Print name: a ...J &- -e- -�i8s7 c7Ae P pig ��S'_ 2770 Fax #: d,-4(3/ -�Or.3/ � 9 Address: 6C9/ /4 e& �� �?1n� ----" City /Stale /Zipy�E90, 1 v,9 94232_ ALL MISCELLANEOUS fF MIT APPLICATIONS MUST BE SUB ► TED WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE'SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER A CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed, by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 CITY OF [UKWILA. NA Account Code 000/345,830 000/322.A0O i.+Ak-A^*h***++++4c+++4*A+A *.44++**a*+*A*a*4+ 02S `` k^*k*A**.*+*4+Ji Y!;:ANSMIT Number: R9900201 AmouNt: `— .�� .. -' Pavment Methudh! CHECK Notation: DESIGN AIR Init: Nrd '' ~--'---~ Permit Nu: A99'O257 Type: H`NE[H MECHANICAL PERMIT |`arue\ No: 336590-0925 Site AdJrusy: 14000 INTERURBAN AV S 1oratiun: MAlNT1:.NANCE FACILITY Total Fees: 1G2.00 This Payment 162.00 Toto( Pmts: 162.00 Balance: .00 71*+++*xA**aAa.A+W*+++b^*x++***AA041****+++*+** Depc,iytinn PLAN CHECK - HON8EG' MECHANICAi ,- KOH8[S, .'-.._~~- 7;A@SNIT 163.00 02/08/00 12:14 A:1 Amount ��9,60 Project: FncY k' c ro /f (17 c) Ty f Irsspectio 1ei Address: C)( . J /, .7 —Vt /*,-1 A/ 7 Joj Special instructions: Date wanted T / } 1 • m. � / 0 - p.m. t Requ - e Phone: 2Oiir — L/33- 117ef • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 COMMENTS: l") w p t `Q «K -) ti�J Approved per applicable codes. E] Corrections required prior to approval. Inspector Date: l '},,.4L1 p o" • 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No: Date: Project: F ! - 11 Type I' Inspection: ' Address: 1 000 / UrI)a w MN Date called: q )8 01 Special instructions: . Pe/tOli`t a t.u' to 4.0 .{"Out, plia44 a &nw 0 ii c ot* P 1J44J 11041 /Aug. moth. Date wanted: /0 - 1 - D 1 a.m. P.m} Requester: s r C. f131) ne: Pho n v4y: �. 7., a: e� +uµ,:t�,:cpr4w.t�carivyyxtSGwV INSPECTION RECOR Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Inspecto „s, i • • PERMIT NO. Date: 10 — i` 0 f 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. El Approved per applicable codes. % Corrections required prior to approval. COMMENTS: 1.) SPCu r.e. C kevQ Srw et (A)4 :1 2) f,.Pri-v■r!At C7 pe4rDUct t P. )1te �ray OVAC. `7 (206)431 -3670, Receipt No: Date: Projec ;_ / '-� �°.. �f��'wsi Typ o Inspe ion: �''' i� Cam'( Address: / Date called: Special instructions: 1 Date wanted: 4/�„ —69 t__�. p.m. Requestter: ,�+ Ph /� / /� /�� // /� INSPECTION RECOR Retain a copy with permit INSPECTION NO. CITY OF TUKVVILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ...,:,:,,,,o r.:�., vsa; r.�ii�x�rxXeyrr£� .�,- tstss:, .! ",v;. PERMIT NO. (206)431 -3670 r Approved per applicable codes. �;[ l Corrections required prior to approval. COMMENTS: J /� / �i / _0 / 1. 41 1 * $47.00 REINSPECTIO 'FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project: Fi.r/ Holt✓ (Corse, rypto shop Type of Inspection: Finn I - /Itec. H Address: I Litt C _En-.r or Ix. c7 A V S Date called: 10 I a� - C Special instructions: Date wanted: IU -- i "1 — 0C- Requester: n✓Y'N Phone: 7 - S 3 -L r, ILI INSP' ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 9818 INSPECTION RECOR Retain a copy with permit r 7!r Mqq-- 0 ?57 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMEN / _ Pte/ CA /1 eA41-yur,57" / 5:5 cio e", - c5 P` e • � ot r �-1 S/ � /9•LI4' r .sir• •-- l� lJrr/,�4 17-) A �4 I 1 1A CJ $47.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION NO. INSPECTION RECORC Retain a copy with permit M,9--.6eS7 PERMIT NO. ./Ver (206)431-36 0 Pro Address: Special instructions: Typepcinspectipn: /Vieft...M Date called: Date wanted:, Requester: Phone: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 X s Approved per applicable codes. E Corrections required prior to approval. COMMENTS: VG^ Fi $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. {_Receipt No: Date: Project y.— L COMMENTS:0 (J7 , .k.. 4 5 je • ' - C 44?,./..--4 3 /l,,, 4 /..•Ar 1...1.4 b e , 6" t 417/ 61 , 4, -1 i .") 1 eZe-rxi .4 ,..?„-idA 4i/i. ,x_hipf,,t,, Cz.-=. .e.i--/- 49 .L Z.. 3' J ka 'ye •g/ :/, 4 # ysee,elif.ei /7- ,74'4.ei c l e r — L i .. ) t- , a n- .61-740.4-e5 ITA:3 ...t. `.--2,0 A r A • Project y.— L Type of j ...1 . 196)r Address: Date called: Special instructions: Date wanted:,, 49 Requester: Phone: • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Li Approved per applicable codes. .0 Corrections required prior to)approval. INSPECTION RECOR Retain a copy with permit M2, PERMIT NO. (206)9.1 El $47.00 REINSPECTI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: ACTIVITY- NUMBER: M99 -0257 DATE: 12 -28 -99 PROJECT NAME: FOSTER GOLF MAINTENANCE FACILITY XX Original' Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # Revision# — After Permit Is Issued DEPARTMENTS: Building Division Aw& 2A-CO Public Works Complete • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ri Comments: TUES /THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved \PRROUTE,DOC 5/99 Approved with Conditions CjI Fire Prevention C i-5 Structural REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions n Planning Division Permit Coordinator Not Applicable n No further Review Required N n n DUE DATE: 12 -30 -99 DATE: DUE DATE 1 -27 -2000 Not Approved (attach comments) ri DATE: DUE DATE Not Approved (attach comments) REVIEWER'S INITIALS: DATE: ACTIVITY NUMBER: M99 -0257 DATE: 12 -28 -99 PROJECT NAME: FOSTER GOLF MAINTENANCE FACILITY XX Original Plan Submittal Response to Incomplete Letter # - Response to Correction Letter # _ Revision # _ After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete PLAN REVIEW /ROUTING SLIP n Structural Comments: TUES /THURS ROUTING: Please Route g Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved \PRROUTE.DOC 5/99 Fire Prevention Approved with Condition REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions 0 11=1.2Z Planning Division U Permit Coordinator Incomplete n Not Applicable No further Review Required DATE: I 3c3 (eLe -I DATE: / Z.aCo n n DUE DATE: 12-30-99 n DUE DATE 1 -27 -2000 Not Approved (attach comments) n DUE DATE Not Approved (attach comments) C REVIEWER'S INITIALS: DATE: ACTIVITY NUMBER: M99 -0257 DATE: 12 -28 -99 PROJECT NAME: FOSTER GOLF MAINTENANCE FACILITY XX Original Plan Submittal Response to Incomplete Letter it Response to Correction Letter # Revision # — After Permit Is Issued DEPARTMENTS: Building Division Public Works Approved U'RROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP t APPROVALS OR CORRECTIONS: (ten days) REVIEWER'S INITIALS: Si 0 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete n Comments: TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: DATE: Approved with Conditions I I U Permit Coordinator Planning Division n DUE DATE: 12 -30-99 Not Applicable n No further Review Required ri DUE DATE 1-27 -2000 Not Approved (attach comments) n DATE: 1 5( d,O(J CORRECTION DETERMINATION: DUE DATE Approved ri Approved with Conditions n Not Approved (attach comments) U REVIEWER'S INITIALS: DATE: r �f •; ��:; , a , .,�: , �� , ;.x�mt�•.xrs ±r..x:.i •r•z'� �nn< <ir;'�.E;;�i'� .�4�"�". �:',; °�'/,�;Nd,'3�{%4�b:�'" Fire Department Review Control #M99 -0257 (510) Dear Sir: City of Tukwila Fire Department January 5, 2000 Re: Foster Golf Maintenance Facility - 14000 Interurban Avenue South Thomas P. Keefe, Fire Chief The attached set of mechanical plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) 2. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) John W. Rants, Mayor u,..,l,....,..n.. .,►r,.... AAA Anilnuns. L11. C,et . TuLvd1a Uhchlnoinn OR1AR • !Anna. /MA) S7S.AAfA • Fir• /2/)Al S7 '4410 Yours truly, C� City of Tukwila Fire Department Page number 2 An aisle to and working space shall be provided for each electrical panel. An'aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110-16(a), NEC 110-16(c)) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. The Tukwila Fire Prevention Bureau cc: TFD file ncd /.....J........a...... ['a..al..�.. AA A Dn..L ❑,../. John W. Rants, Mayor Thomas P. Keefe, Fire Chief .1.4 .d1n TAI nl.lnea". 11D1 DO aa' D/........ PI/1M e'w A AAA • C....: 1011A1 e'f_AAOn November 6, 2000 Mr. Candido Gavino T.F. Inc. 830 N. Riverside Dr. Renton, WA 98055 Dear Mr. Gavino: Sincerely, ,(2 ) • D u an e r Gnab Building Official C of Tukwila Department of Community Development The following is in response to your letter dated October 25, 2000 regarding the issue of installing a smoke damper in the occupancy separation wall at the Foster Golf Course Maintenance Facility. After thoroughly reviewing this subject I have determined that a smoke damper is and will be required in the supply duct where it penetrates the occupancy separation wall. Section 713.10 of the UBC states that smoke dampers complying with approved recognized standards shall be installed in ducted or unducted air openings at penetrations of area or occupancy separation walls. This appears to be a very specific code requirement. I understand this same section then goes on to say that a smoke damper need not be provided when it can be demonstrated that the smoke damper is not essential to limit the passage of smoke under passive conditions. However, based on the HVAC plan attached to your letter, I don't think the "passive conditions" term can be applied to this situation. It appears to me that any smoke, generated on the other side of the wall from the shop area, could migrate and be distributed through the duct system that penetrates the occupancy separation wall. The comments in your letter seem to be based on the rationale that a smoke damper installed in the occupancy separation wall would be installed solely to prevent smoke generated in the shop bay from entering the small room and then migrating to the other side of the wall. If that were the only consideration I would tend to agree that the need for a smoke damper might be questionable. However, based on my reading of the code, I have no reason not to think that the intent of the code is to prevent smoke from penetrating the wall from either side. If you should have any further questions or comments regarding this subject please feel free to contact me. Steven M. Mullet, Mayor Steve Lancaster, Director 11 0257 6300 .Southcenter Boulevard. Suite #100 • Tukwila_ Washington 9RIRR • Phone! 208.4. 71._ 1157n • Far! 2n6.d_ ?1..v t 4 a w 0— 0 ..� ..•ili4:! x 4 t..t i w:'.. . `'14,41:44: m:, or 4, 4sroP... r.lr.&e•twvmurnvitI.Y.iPtJlAY42 : ii :'44"M'Miar 4 *414:4` „r Ifett3 u I hmegzgen% F- it V Ie L7 mitnerin nnn2 t.n :nh 'nt /2 1111 1.14 t Wnh[ \fiMn_.laianit .� I 1997 UNIFORM BUILDING CODE, VOLUME/ 713.8 Fire Window Size. Fire windows required to have a three - fourths -hour fire- protection rating for protection of openings in exterior walls shall have an area not greater than 84 square feet (7.8 m with neither width nor height exceeding 12 feet (3658 mm) and for protection of openings in interior walls shall be limited in area and size to that tested. 713.9 Glazing. Glazing materials and glass block assemblies shall be qualified by tests in accordance with UBC Standard 7 -2 (for fire doors) or UBC Standard 7 -4 (for fire windows) as appropriate for the use, and they shall be labeled for the required fire- protection rating and installed in accordance with their listing. Glazing in fire door assemblies and in fire window assemblies subject to human impact in hazardous locations as indicated in Section 2406.4 shall comply with Section 2406.3. 713.10 Smoke Dampers. Not less than Class II, 250 °F (121 °C) smoke dampers complying with approved recognized standards (see Chapter 35, Part IV) shall be installed and be accessible for in- spection and servicing in the following ducted or unducted air open- ings at: 1. Penetrations of area or occupancy separation walls. 2. Penetrations of the fire- resistive construction of horizontal exit walls or corridors serving as a means of egress. EXCEPTION: Openings for steel ducts penetrating the required fire - resistive construction of corridors are not required to have smoke damp- ers when such ducts are of not less than 0.019 -inch (0.48 mm) thickness (No. 26 galvanized sheet steel gage) and have no openings serving the corridor. 3. Penetrations of shaft enclosures. EXCEPTION: Exhaust -only openings serving continuously operat- ing fans and protected using the provisions of Chapter 9. 4. Penetrations of smoke harriers. 5. Penetrations of elevator lobbies required by Section 403.7 or 1004.3.4.5. 6. Penetrations of areas of refuge. EXCEPTION: Ventilation systems specifically designed and pro- tected to supply outside air to these areas during an emergency. A smoke damper need not be provided when it can be demon- strated that the smoke damper is not essential to limit the passage of smoke under. passive; conditions and the proper function of a smoke - control system complying with Chapter 9 does not depend :j on the operation of the damper. Smoke dampers may be omitted at openings that must be maintained open for proper operation of a mechanical smoke- control system, provided that adequate protec- tion against smoke migration, in the event of system failure, has been provided. Smoke dampers shall be closed by actuation of a smoke detector installed in accordance with the Fire Code and one of the following applicable methods: 1. Where a damper is installed within a duct, a smoke detector shall be installed in the duct within 5 feet (1524 mm) of the damper with no air outlets or inlets between the detector and the damper. The detector shall be listed for the air velocity, temperature and humidity anticipated at the point where it is installed. 2. Where a dumper is installed within an unducted opening in a wall, a spot -type detector listed for releasing service shall be installed within 5 feet (1524 mm) horizontally of the dumper. 3. Where a damper is installed in a ceiling, a spot -type detector listed for releasing service shall be installed on the ceiling within 5 feet (1524 mm) of the damper. 4. Where a damper is installed in a corridor wall or ceiling, the damper may be controlled by a smoke- detection system installed in the corridor. EI October 25, 2000 Dear Mr. Griffin: Respectfully, Candido B. Gavino, PE Mechanical Engineer Attachment: Partial Plan T.E. Inc.( 830 N. Riverside Drive, Renton, WA 98055 Phone: 206 -241 -2012 / FAX: 206 - 241 -3101 Mr. Duane Griffin, Building Official City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Thank you for your kind consideration. Subject: Foster Golf Course Maintenance Facility (TEI #: 98 -140) 14000 Interurban Avenue South Tukwila, WA RECEIVED OCT 31 2000 COMMUNITY DEVELOPMENT Because the building is substantially complete, replacement of the damper will require considerable demolition and reconstruction. We are therefore invoking the exception in the Code and request your approval. 98 -140 Bldg. Dept.l.doc os Please refer to the attached partial plan of the above subject building. We specified a fire damper in the duct at the Occupancy Separation wall between a 65 square foot room and the main office areas of the building. The Inspector has informed the Contractor that a smoke damper will be required. We discussed the issue with the Inspector, Mr, Doug Larson, who further referred us to Mr. Bob Benedicto. I pointed out to Mr. Benedicto that although the Code generally requires a smoke damper at this location, there is an exception in the Code that "A smoke damper need not be provided when it can be demonstrated that the smoke damper is not essential to limit the passage of smoke under passive conditions..." under UBC Section 713.10. You will note that the room does not have a return air duct. Should there be smoke in the Shop room, the positive pressure in the duct during A/C operation will prevent the smoke from entering it. If the A/C were not operating, the path of least resistance will be through the Shop Bay since there are fewer restrictions between the room and the outside compared to the duct route. While Mr. Benedicto has expressed that the foregoing argument reasonably meets the criterion of the exception in the Code, he feels that he is not in position to make the decision to allow the exception, and further referred us to your office. OUTDOOR HVAC UNIT v Ngi FLEX. i I I RG -1 U' CD-1 1 355GR1 IN i 0 tit D TOILET EXHAUST FAN ;r B' =7 _2 iI X H _HI � l GD - 1 110CFM ,� 22°C;141 r 9^ GD-1 8x6 •. CONN. ` Ii Ig o FLEX , • v (I L e v 8' CD -I 180XCRM TOILET EXHAUST FAL g m FLEX. CONN. m 12k12DG -I GRILLE M.ORI D DAMPER INTERLOCK WI EF-5 tt r ' 8X6 v DE m s'epm*Iw 36 24' RUSKIN ELF315D OA. LOUVER UN IT WALL CAP RG 111DOP1 4 RETURN AIR DUCT 10' RG -1 10' CD -3 300GR1 RETURN AIR PLENUM a 10' CD -3 300GR1 WALL CAP WALL CAP 1=1:1= l O WALL CAP DRYER EXHAUST FAN n 44/36 LOUVER WITH MOTORIZED DAMPER INTERLOCKED WITH FAN EF -10 1 I1 0' 14/24 LOUVER AND PLENUM 12' WAL . CAP i FLEX. M IDIFIER /24 LOUVER 'W/MOTO DAMPER INTERLOCKED WITH FAN EF -1 HVAC PLAN - MAINTENANCE BUILI I SCALE: 1/8" = 1' -0" • • •• : • • •• • . • . • • „ • . ' • : • , .* • SHEET SCINEDULE SI-IT. SHEET DESCRIPTION T -I TITLE SHEET T -2 SITE SURVEY C -I CIVIL SITE PLAN C -2 CIVIL DETAILS 1 SITE PLAN 2 CREW BUILDING FLOOR PLAN 3 CREW BUILDING EXTERIOR ELEVATIONS 4 EQUIPMENT SHED FLOOR PLAN 5 EcaemENT S,-1ED ELEVATIONS 6 ROOF PLANS 4 DETAILS 1 DOOR SCHEDULE ' DETAILS 8 WALL SECTIONS 9 WALL SECTIONS 10 WALL SECTIONS li REFLECTED CEILING PLAN 12 INTERIOR ELEVATIONS 13 INTERIOR DETAILS 14 MATERIAL STORAGE 15 WASH ISLAND SITE DETAILS 16 FUEL ISLAND SID GENERAL STRUCTURAL NOTES 4 DETAILS SI CREW BUILDING FOUNDATION PLAN t DETAILS 52 CREW BUILDING ROOF PLAN a DETAILS S3, CREW BUILDING SHEAR WALL -PLAN 4 SCH. 54 TRUSS DIAGRAMS - NOTES 55 E SHED FOUNDATION PLAN e DETAILS 55 EQUIPMENT SHED ROOF PLAN DETAILS SME1 SITE PLAN: MECHANICAL 4 ELECTRICAL M -1 CREW BUILDING I-VAC PLAN M -2 CREW BUILDING PLUMBING -PLAN M -3 CREW BUILDING MECHANICAL SCI-1.6 a DETAILS ME -I EQUIPMENT SHEDS / MECHANICAL / ELECTRICAL PLAN E -I ONE LINE DIAGRAM, LEGEND 4 SCHEDULE E -2 CREW BUILDING POWER PLAN E -3 CREW BUILDING LIGHTING PLAN SE -I SECURITY PLAN ZONE OCCUPANT TYPE CREW BLDG. (OFFICE) B -2 CREW BLDG. (SHOP & EQUIP. STOR.) S -3 EQUIP. SHEDS S -3 WASH ISLAND S -3 CONST. TYPE CREW BLDG. V -N SHOP BLDG. V -N WASH ISLAND V -N SQUARE FOOTAGES CREW BUILDING 7,990 S.F. EQUIPMENT SHED 3,094 S.F. ALL WORT( SHALL BE DONE IN ACCORDANCE WITH UNIFORM BUILDING CODE 1551 EDITION CREW BUILDING SHALL COMPLY WITH TABLE 13 -1 OF THE WASHINGTON STATE ENERGY CODE 1991 EDITION FOR GAS FIRED 1- 1EATING SYSTEM VICINITY MAP L_ � J City Administration. Project Manager A. Thomas Pulford Tukwila City Council Members Dave Fenton, President Pam Carter Joe Duffle Joan Hernandez Pamela Linder Steve Mullet Jim Haggerton John W. Rants, Mayor John McFarland, City Administrator Jane Cantu, City Clerk Jun Morrow, P.E., Director of Public Works Don Williams, Director of Parks and Recreation CIVIL ENGINEER C K S Re id BV FILE COPY I understand that the Plan Check approvals ar ,ect to errors and omissions and approval � ians does not authorize the , '10,:1:1011 of an opted code or orenanca. Re s -pt.of con tractor's copy I pprovedpia sau"' owledce. Date M - � A o � 2v�.it Perm it No "'" • -or - RECEIVED OCT 1 9 1999 TUKWILA PUBLIC WORKS PROJ. NO 9814 TITLE SHEET DATE: 7/22/99 REV. NO. REV. DATE DWG BY: CFWC'D BY: PY.CT rrz:///, fr-1, "&x.A. O UR IVARY & ASSOCIATES 5651 UNIVERSITY WAY NE SEATTLE 1 N .T N 98 105 PH: (206) 525 -8020 �f FAX. — s. E MAIL: — IVARY@NWL INK .COM STRUCTURAL - CIVIL ENGINEERS PWA ENGINEERS 10709. BEARDSLEE BLVD BOTHELL, WASHINGTON 98011 PH: (425) 806 -5203 FAX: (425) 806 -5204 MECHANICAL - ELECTRICAL ENGINEERS TEI 1490 INTERURBAN AVE_ S ste. 203 TUKWILA, WASHINGTON 98168 PH: - (206) 241 -2012 FAX: — (206) 226 -7901 JAEGER ENGINEERING 9419 S. 204th PLACE KENT, WASHINGTON 98031 PH: — (253) 850 -0934 FAX: — (253) 850 -0155 L_ , J' CITY OF TUKWILA 6200 Southcenter Boulevard Tukwila, Washington 98188 ARCHITECT SEPARATE 0 PERMIT RECUT. ❑ MEv':IAt1I0A1. ❑ PLL 0 cr PIPING CITY OF TU'^ BUILDING DIVISION i CITY ORTU I1 A DEC 2 8 1999 PERMIT CENTER 36 HVAC EQUIPMENT SCHEDULE SYMBOL fTEM SERVES MFR /# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES. - v HEAT PUMP O UTDOOR UNIT OFF10E�S TRANE TWAO48A300 4 TON SPLJT SYSTEM HEAT PUMP OUTDOOR SECTION SINGLE COMPRESSOR, 230V/350/601-{Z, PROGRAMMABLE SETBACK 2 STAGE COOLING, 3--STAGE HEATING PSTAT, PROVIDE WITH HEATPUMP RELAY KIT, 230V/30 16.0/1.9 ELI FR1 FLANGED FRAME FOR HARD CEILING. INSTALLATION. PLAN M -1 _ 1 v AIR HANDLING UNIT OFFICES TRANS TWEO60A3- 5 TON SPLIT SYSTEM HEAT PUMP INDOOR SECTION 1960 CFM 0 1.0" SP, 2 —HP MOTOR, CENTRIFUGAL FAN FOR HORIZONTAL INTALLATION: 230V/30 4.3,0 FLq SUPPLY PLAN M -1 BORDER TYPE I FOR SURFACE MOUNT SIZES PER PLAN EF -1 EXHAUST FAN SHOP CARMON CMB10 1000 CFM 0 1.50' SP, VEHICLE EXHAUST SYSTEM, WE-I STAINLESS STL HORIZONTAL RIGID DUCT, TYPE CLX FLEX DUCT DROPS AND SERIES EVH QUICK RELEASE ADAPTER. 3/4 HP 120V/10 120# HVAC PLAN M_1 MANUAL SWITCH BY E.C. O..® EF -2 CEIUNG EF FAN MEN TOILET RM. PENN Z8H 275 CFM 0 .375 S.P., SPEED CONTROL IN FAN CABINET 130 WATTS 120\/10 2p # PLAN M -1 INTERLOCK WITH. LIGHT SWITCH BY S.C. Q, EF -3 EXHAUST FAN WOMEN TOILET RM. PENN Z8H 230 CFM' 0.375" SP, SPEED CONTROL IN FAN : CABINET 130 WATT 120V/10 20# PLAN M -1 INTERLOCK WITH LIGHT SWITCH BY E.C. EF -4 EXHAUST FAN DRY ROOM PENN ZBS 185 CFM 0.375" SP, SPEED CONTROL IN FAN CABINET. 77 WATTS 120V/10 20 #. PLAN M -1 INTERLOCK WITH LIGHT SWITCH BY E.C. 0 EF -5 EXHAUST FAN GRINDING ROOM PENN Z8H 295 CFM ®.375" SP SPEED CONTROL IN FAN CABINET .130 WATT 120V/10 : 20# PLAN M -. MANUAL SWITCH BYE C EF -9 LOCKER RM. CONTROL BY TIME SWITCH TS -1 EF -6 EXHAUST FAN STORAGE ROOM PENN Z81S 200 CFM 0 .375 SP, 2950 RPM SPEED CONTROL IN FAN CABINET 77 WATT 120V/10 20# PLAN M -1 MANUAL SWITCH BY E. C. EF -7 EXHAUST FAN EQUIPMENT STORAGE PENN DOMEX DX11B 1000 CFM 0 0.75 SP. ROOF EXHAUSTER 1/2 HP 120V/10 55# PLAN M -1 16" SQ. ROOF OPENING CONTROLLED BY TIME CLOCK TS -1 0 0 EF -B' EXHAUST FAN IRRIGATION ROOM PENN Z81S .200 CFM 0 .375" SP, 2950 RPM SPEED CONTROL IN - FAN CABINET 77 WATT 120\ 10 / 20 # PLAN M -1 CONTROLLED BY TIME CLOCK TS -1 2 - Q EF -10 EXHAUST FAN SHOP PENN DX11B 1675 CFM ® .375" SP, 1174. RPM ROOF EXHAUSTER 1/3 HP 120V/10 120 #. PLAN M -1. CONTROLLED BY TIME CLOCK TS—i Q EF -11 EXHAUST FAN OIL 'DRUM ROOM PENN ZBS : 185 CFM 0.375 SP, SPEED. CONTROL IN FAN CABINET. 77 WATT 120V/10 . 20# KLAN M -1 CONTROLLED BY TIME CLOCK TS -1 O ®,. DH -1 DEHUMIDIFIER DRY. WHITE WESTINGHOUSE 25 PINTS, 2 SPEED FAN, 249 CFM, STOCK No. 3H291 AUTOMATIC HUMIDISTAT, FROST CONTROL, COLLECTOR W /GARDEN HOSE. 115 \ /10 5'. AMPS, , 51# PLAN M -1 AUTOMATIC OVERFLOW CONTROL ]111 -1 UH -2 UH -3 UNIT HEATER - SHOP _ EQUIPMENT STORAGE FE -25 25,000 BTUH INPUT, 20,000 BTUH OUTPUT, GAS— FIRED, 380 CFM,1 /50 —HP' MOTOR, 10" FAN DIAMETER SUSPENDED. 230 \ /16 :75 #I P LAN M 1 PROVIDE T'STAT WITH NIGHT SETBACK TS-1 TIME SWITCH E— 5, : 7 8, 9.10,11 TORK W220L PROGRAMMABLE, 7 —DAY DPST, RESERVE POWER, GENERAL PURPOSE ENCLOSURE 120 0 AC UNITS TO BE SUPPLIED WITH LOW LEAK DAMPERS, ECONOMIZER, BAROMETRIC RELIEF, AND THROW -AWAY FILTERS. 0 PROVIDE BACKDRAFT DAMPER. : U',�Y U TJ ' E D �0 AC UNIT TO BE SUPPLIED WITH PROGRAMMABLE ELECTRONIC NIGHT SET —BACK THERMOSTAT. (•f PR A C) ROOF CURBS PROVIDED BY METAL ROOF SUPPLIER. , ' ;, , 1JU I � ® I TO SHUT OFF EF -4 WHEN, DEHUMIDIFIER IS OPERATING. E '� AIR TERMINAL SCHEDULE SYMBOL MANUFACTURER SERVICE MODEL FRAME NOTES CD -1 TITUS '. SUPPLY MCD FR3 FRAME FOR T -BAR CEILING INSTALLATION. SIZES PER PLAN CD -2 TITUS SUPPLY MCD FR1 FLANGED FRAME FOR HARD CEILING. INSTALLATION. SIZES PER PLAN. CD -3 TITUS SUPPLY TMR NO FRAME — FOR AREAS WITH NO CEILING SIZES PER PLAN WG -1 TITUS. SUPPLY 301 RS BORDER TYPE I FOR SURFACE MOUNT SIZES PER PLAN RG -1 TITUS RETURN CORE 50 BORDER TYPE 1 FOR SURFACE MOUNT SIZES PER PLAN DG -1 TITUS DOOR T -700L . BORDER TYPE 1 SURFACE MOUNT. W /AUX. FRAME SIZES - PER.PLAN OUTDOOR UNIT v 36'x ZA' M IN ELF316D OA LOJVE' UNIT © 2 3 da IR DUCT A WALL OAP /36 LOUVER WITH MOTORIZED DAMPER INTERLOCKED WITH PAN EF-I0 WALL OAP E FAN Mf24 LaIV R AND PLBili HVAC PLAN MAINTENANCE BUILDING SCALE: 1 /B° = P -0" f IS"BY: _ :Io MI OP DEC 2o PERM PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION MFR. /MODEL WASTE VENT COLD W. HOT W. SPECIFICATIONS DETAIL SERVES NOTES ( WC ) WATER CLOSET AMERICAN ST. AFWALL EL1.6.2257.103 4" 2 1" ___ WALL HUNG, SIPHON JET, ELONGATED BOWL WHITE VITREOUS CHINA, WATER SAVER, FLUSHES ON 1.6 GALLONS, MIN. WORKING PRESSURE -30 PSI AT VALVE WHILE FLUSHING. SLOAN ROYAL FLUSH VALVE #111 W /1" SCREWDRIVER BAK -CHECK ANGLE STOP, ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION & SPUD. COUPLING FOR 1 -1/2" TOP SPUD. BEMIS 1655SSC INSTITUTIONAL, EXTRA HEAVY OPEN FRONT TOILET SEAT FOR ELONGATED BOWL, NO COVER, STAINLESS STEEL HINGE W /CHECK. C 4� ( LAV ) LAVATORY AMERICAN ST. OVAL HORIZON 3303.000 1 -1/2" 1 -1/2 1/2" 1/2" WHITE ENAMELED, CAST IRON NOM. DIM. 19" INCH, COUNTERTOP 4 INCH FAUCET HOLE CENTERS. LAVATORY FAUCET SHALL BE CHICAGO FAUCET NO. 844 -669 ADA COMPLIANT METERING FAUCET WITH ADJUSTABLE TIME CYCLE. 4-1_/8" SPOUT MIXING TEE, INLET CHECK VALVE & 4" CENTERS. LESS THAN 5 POUND FORCE REQUIRED TO OPERATE. RESTROOMS, Q ( UR ) URINAL AMERICAN ST. TRIMBROOK 1.0 6561.017 z, _1 2 3/4" WALL HUNG, WHITE VITREOUS CHINA, ',LOW CONSUMPTION, 1.0 GPF, FLUSHING RIM, SIPHON JET FLUSH ACTION, EXTENDED SIDES FOR PRIVACY, 3/4" INLET SPUD, 20UTLET, 2 WALL HANGERS, SLOAN ROYAL. FLUSH VALVE MODEL 186 -1 LOW CONSUMPTION. RESTROOMS, CD SHOWED SHOWER KOHLER K-12,14 1 2" 2 1/2" 1/2" 42"WX36- 1 /2 ".DX77H'WHEELCHAIR ACCESSIBLE SHOWER FEATURES FOLDING STAINLESS STEEL /PLASTIC TRANSFER SEAT, FULL WIDTH TOILETRY SHELF ON REAR WALL, .,... '" -'' ACCOMMODATES BATHING IN OR OUT OF WHEELCHAIR. SUPPLY WITH MOEN HANDHELD SHOWER (NON - METAUC) MODEL NO 3982, 69" DOUBLE INTERLOCK SPIRAL HOSE(METAL). VACUUM BREAKER. 24" SLIDE BAR(METAL). DFSIGNFO TO 09 NFR 2 5 GPM AT 60 PSI RESTROOMS, C ( WS SERVICE SINK KITCHEN SINK AMERICAN ST. AKRON 7695.018 ELK" DLR- 3322 -10 3" 1 -1/2 1-1/2° 2 1 -1/2 3/4 3/4 1/2. ENAMELED CAST IRON SERVICE SINK WITH RIM GUARD, AMERICAN STANDARD FAUCET 8341.075 FAUCET WITH VACUUM BREAKER & STOP SHANKS, 3" TRAP STANDARD. PROVIDE COMPLETE W /METAL RIM GUARD. STAINLESS STEEL, LKA -2448 FAUCET COLLAR, NICKEL BRONZE ADJ. HEAD SHOP CREW RM. ( KS (FD -1) FLOOR DRAIN ZURN ZN- 415 -P. -S 3" 2 ADJUSTABLE STRAINER HEAD FLOOR DRAIN WITH DUCO - COATED CAST IRON BODY, FLASHING COLLAR, NICKEL BRONZE ADJ. HEAD. RESTROOMS, SHOP AREA, DRY ROOM 0 ( SI -1] SAND INTERCEPTER SMITH CO. 8811_20 4" 3" UNIT CAPACITY (STATIC) OF 60 GAL AND MAX.OF 20. GPM FLOW RATE. UNIT SHALL HAVE PRIOR APPROVAL BY LOCAL JURISDICTION BEFORE ORDERING. CONTRACTOR TO VERIFY INLET /OUTLET PIPE LOCATIONS AND SIZE. (WH -1) (CP -i) WATER HEATER - 120'F A.O.SMFTH BTC -120 1" 1" 75 GAL, 120 MBH INPUT, 145 GPH 0 100' RISE, DRAIN PAN, 1030 LBS. W/ EXPANSION TANK RESTROOMS, DRY RM, CREW RM. CD CIRCULATING PUMP GRUNDFOS UPS 15 -18SU 1 � 2 1 SPEED , 1/35 HP, 65 W, 115 V. 0.57 AMPS ' 2865 RPM. 1 GPM CO 7.2 FT HEAD ALL STAINLESS STEEL CONSTRUCTION. WATER HEATER WH -1 ( C -1) AIR COMPRESSOR 1" AIR CONNECTION. AIR COOLED PUMP MOUNTED ON / MBF69 BAKERY GALLON RECEIVER WITH AUTOMATIC DRAINER, 208V/30, 3HP. Q2 ( FIB-1 ) ( WHA HOSE BIBB WOODFORD 65C 3/4" +24" FROST PROOF, AUTOMATIC DRAINING FREEZELESS HYDRANT, LOOSE KEY. CD WATER HAMMER ARRESTOR ZURN i SHOKTROL SERIES, MODEL #600 c WATER CLOSETS TO HAVE OPEN FRONT SEATS AND ELONGATED BOWLS. 1.6 GPF MAX. l i CD ALL HOSE BIBBS TO HAVE NON - REMOVABLE BACKFLOW PREVENTION DEVICES - TAMPER PROOF VACUUM BREAKER. WATER HEATERS TO HAVE RIGID CONNECTIONS & CONSTRAINTS TO RESIST SEISMIC MOTION. ® HANDICAP WATER CLOSETS SHALL . BE +16' TO TOP. OF BOWL FLUSH VALVE LEVER CONTROLS TO BE ON THE WIDE SIDE OF STALL AND NOT MORE THAN 44. INCHES ABOVE THE FLOOR. C.:) .LAVATORIES'.SHALL BE +34. TO RIM, WITH 29" OF CLEAR SPACE UNDERNEATH, HOT WATER AND DRAIN PIPES UNDER LAV SHALL BE INSULATED PER SPEC. SECTION 15180.'. '.. SELF CLOSING VALVES SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS PER OPERATION. CD URINALS SHALL BE WATER SAVER TYPE. 1.0'. GPF MAX. PROVIDE TRAP PRIMER. ® LOCATE ALL VENTS THRU ROOF AT LEAST 10' IN FROM ROOF PARAPET. RECESS FLOOR . "2" :- FOR SHOWER INSTALLATION' - 17" g locA to-Js :. GAS SIZING CHART MA X DISTANCE ■ low . eft I ( uPC.in, TIME 12, 1/2 50'CFH 3/4 '104 CFH 1" 197'CFH 1 -1/4" 404CFH 1 -1/2 605CFH 2 1165 CFH VENT THRU ROOF SCALE: NONE AIR OUTLET STATION PIPINGS MOUNTING DETAIL SCALE: NONE P - SCALE: NONE INTERIOR FLOOR CLEANOUT FLEX DUCT WHERE NOT EXPOSED ONLY FRAMING SEE STRUCTURAL DRAWINGS RECIRC. PUMP GRUNDFOS, MODEL UPS 15 -42 F PARAGON TIMER #4001 BY M.C.'. SCALE NONE HW SUPPLY,' SIZE PER PLANS THERMOMETER ASME P &T RELIEF VALVE EARTHQUAKE STRAP OR CHAIN ATTACHED TO BUILDING. (TYP OF 2). DRAIN VALVE 6 FLUE PER LOCAL CODE 1" CW SUPPLY -t.. 1/2" HW9 ( CP -1 cal GAS SHUT -OFF VALVE DIRT LEG U CATCH PAN PIPE TO FLOOR DRAIN. KEEP PIPING CONCEALED WITHIN WALLS. NIMIN SCALE: NONE FLEX DUCT 10' MAX. NYLON TIE STRAPS LAY -IN CEILING DIFFUSER DIFFUSER INLET DETAIL VOLUME DAMPER ' is. DUCT HANGER RODS (TYP.) FUZC. CONN. SUPPLY DUCT (UNE SECT SUPPLY AIR MOT. DAMPER UNED SHEETMETAL PLENUM &4 I' III 1 RETURN AIR DUCT FLEX CONN. FAN COIL UNIT S TYPICAL FCU AND AHU -1 CONNECTION DETAIL SCALE: NONE -TRAP 1' TO CONDENSATE DRAIN OUTSIDE AIR DUCT AND LO(AIER. SIZE. PER PIAN IGERANT UNES'' TO'. OUTDOOR SECTION SUPPORT RODS WATER HEATER WH -1 SEAL W/ HIGH TEMP SILICONE SEISMIC BRACING 1X1X1/16 STEEL ANGLE. PROVIDE IN I TWO DIRECTIONS... UNIT HEATER {■ 45' ROOF SCALE: NONE FLUE -- EXHAUST �� 5 "4 FLUE EXHAUST PIPE FLASHING FLASHING ROOF GAS CALCULATIONS NEW GAS LOAD UNIT HEATER UN -1 (3 ® 25,000 STUN) 75,000 BTUH WH -1 120,000 BTUH TOTAL NEW LOAD 195,000 BTUH' -. TOTAL CONNECTED LOAD 195,000 BTUH PROVIDE 1 "GAS LINE 21/2x21/2x1/4 STEEL CHANNEL OR UNISTRUT WELDED TO UNDERSIDE OF ROOF. OBTAIN PERMISSION FROM STRUCTURAL ENGR. PRIOR TO WELDING TO STRUCTURAL MEMBER. PROVIDE SEIMIC BRACING. FLUE EXHAUST PIPE 30' MAX. UNION GAS SHUT OFF GAS UNE TO TRUSS SPACE SIZE PER PLANS UNIT HEATER DETAIL DIRT LEG MECHANICAL LEGEND A AIR CWV .COMBINATION WASTE/VENT WASTE /SANITARY SEWER VENT G GAS COLD WATER HOT. WATER HOT WATER RECIRC. VTR VENT TO ROOF FCO FLOOR CLEAN OUT k 24/48'% AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCT CONNECTION FC SUPPLY DUCT UP RETURN DUCT UP DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND . DUCT TRANSITION FIRE DAMPER (FD) AIR CONDmONER # CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE WET BULB TEMPERATURE MBH 1,000 BRITISH THERMAL UNITS /HR. PSI POUNDS PER SQUARE INCH ESP EXTERNAL STATIC PRESSURE EC EXHAUST GRILLE RG RETURN GRILLE CD CEILING DIFFUSER 13' A.F.F. UNIT HEATER 6' 0" MIN PROW.: 98 -140 DATE: 6/18/98 REV. NO. RE''. DATE DWG WY. ,CHK'D WY :.