HomeMy WebLinkAboutPermit M99-0258 - BEST BUY' ;': $i i ;') 1∎;41. ±Y.i�'h�. f f Y ;4y }V r. �..
M99 -0258
17300 Southcenter
Pkwy.
City of Tukwila - : (206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
Permit No: M99 -0258
Type: B -MECH
Category: NRES
Address: 17300 SOUTHCENTER PY
Location:
Parcel #: 262304 -9079
Contractor License No: MERITMI163CM
TENANT BEST BUY Phone:
17300 SOUTHCENTER PY, TUKWILA, WA 98188
OWNER MBK NORTHWEST Phone: 206 575 -8090
C/O TRAMMEL CROW COMPANY, 17560 SOUTHCENTER PY, TUKWILA WA 98188
CONTACT JESSICA COYLE Phone: 503 - 223 -8030
222 SE COLUMBIA #1250, PORTLAND, OR 97201
CONTRACTOR MERIT MECHANICAL INC. Phone: 206 883 -9224
9630 153RD AVENUE N.E., REDMOND, WA 98052
******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Description:
DD NEW HVAC SYSTEM.
UMC Edition: 1997
******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Center - A rized Signature Date
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this b lding permit.
Signature:_ Date:
Print Name: S Title: AjAbl-
MECHANICAL PERMIT
Valuation: 2,028,072.80
Total Permit Fee: 580.19
Status: ISSUED
Issued: 05/04/2000
Expires: 10/31/2000
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
CIlY OF TUKWILA
Address: 17300 SOU1HCENTER PY Permit, No: M99-0258
Suite:
lenant: BES1 BUY Status: ISSUED
lype: B-MECH Applied: 12/28/4999
Parcel 0: 262304-9079 issued: 05/04/2000
**********************k***************************************
Permit Conditions:
1 Readily accessible access to roof mounted equipment is
required.
2. Plumbing permits shall be obtained.through the Seattle-Ktng
County Department of Publtc Health. Plumbing be
inspected by that' including ,all gas piping
3. Electrical permits shall be obtained the WaShington
State Divislon of Labor and industries and all, electricaT
work will be inspected by that agency (248-6630).
,
4 No changes will be inade to the plans unless approved by the
Engineer ,and the Tukwila Building Division.
5. All perits,, inspection records, and approved plans shall be
available at the job site prior to the start of any con-
struction. These documents are be maintained and avatl
■
'able'until final inspeCtion approval is granted.
6. , All construction to be done in conformance with approved .
plans and requirements-of the Uniform:Building Code (1997
Edition) as amended; Uniform Mechanical,Code (1997 Edition):
andWashington State Energy,'Code (1997 Edition).
7. Validity of Permit. The issuance,of,a permit or approval Of
plans, specifications, and computations shall riot be con-
strued to be a'permit for or an eppro'vel,of, any violatton
of any of the provisions of the building/codc,or of any
other ordinance of the jurisdiction. No permit presuming to
give authority to violate or cancel the provisions of,thts'
code shall' be 'valid
8, ManufaCturers installation instructions 'required site
for the building inspectors review.
Project Name/Tenant:
Parkway Supercenter /Best Buy
Value of Mechanical Equipment:
$2.028,072.$0
Site Address : City State/Zip:
17300 Southcenter Tukwila, WA 9A18A
Tax Parcel Number:
__„262 '1(14 - 907q
Property Owner:
MBK Northwest
Print nam 11, Je Coyle
Phone: ( 5 03 ) 636 - 133 1
Street Address:
4949 SW Meadows Rd, #675 Lake Os we
City State/Zip:
97.035
Fax #: ( )
503 636 - 1331
Contractor:
Pcrt. l and. OR 97201
Phone: ( )
Street Address:
City State/Zip:
Fax It: (
Contact Person:
Jessica Coyle
Phone: ( )
503 223 - 8030
Street Address:
222 SW Columba :1250 Portland •R
City State/Zip:
97201
Fax #: ( )
503 223 - 8381
BUILD! .greQ AUTHORIZED AGENT:
Signatu 5W,31111Sir •
Date: 12/22/99
Print nam 11, Je Coyle
Phone: ( 50 3 )
223 - 8030
Fax #: ( 503 ) 223 -8381
Address:
222 SW Columbia #1250
City / State/Zip:
Pcrt. l and. OR 97201
CITY OF TUk VILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Project Number:
Permit Number:
Mechanical Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
Description of work to be done (please be specific):
New HVAC systems
MECHANICAL PERMIT REVIEW.. AND APPROVAL' REQUESTED: (TO BE FILLEDOUTBY APPLICANT)
Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of
application, a copy of this license will be required before the permit is issued OR submit Form H-4, "Affidavit in Lieu of Contractor
Registration ".
Building Owner /Authorized Agent: If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the
State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the
permit will be required as part of this submittal.
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written
request by the applicant as defined in Section 114.4 of the Uniform Mechanical Code (current edition). No application shall be
extended more than once.
Date application accepted:
1/2/99
Date application expires:
Application taken by: (initials)
✓
X
Submittal Requirements
Floor plan and system layout
X
Roof plan required to identify individual equipment and the location of each installation (Uniform
Mechanical Code 504 (e))
Details and elevations (for roof mounted equipment) and proposed screening
X
Heat Loss Calculations or Washington State Energy Code Form #1-I -7
X
H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection shut-
off and will be routed to the Fire Prevention division for additional comments (Uniform Mechanical
Code 1009).
X
Specifications must be provided to show that replacement equipment complies with the efficiency ratings
and other applicable requirements of the Washington State Nonresidential Energy Code.
X
Structural engineer's analysis is required for new and the replacement,of existing roof equipment
weighing 400 pounds and greater (Uniform Building Code 1632.1). Structural documentation shall be
stamped by a Washington State licensed Structural Engineer.
Mechanical Permits
COMMERCIAL: Two complete sets of drawings and attachments required with application submittal
11/2/99
rniscpnu,doc
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
RESIDENTIAL: Two complete sets of attachments required with application submittal
Submittal Requirements
New Single Family Residence
Heat loss calculations or Form H -6.
Equipment specifications.
Change -out or replacement of existing mechanical equipment
I Narrative of work to be done, including modification to duct work.
Installation of Gas Fireplace
Narrative with specification of equipment and chimney type.
If using existing chimney, provide a letter by a certified chimney sweep stating that the chimney is in safe
condition.
NOTE: Water heaters and vents are included in the Uniform Mechanical Code — please include any water
heaters or vents being installed or replaced.
**************************** *******c************************
CITY OF WA IM1••
TRANSMIT
******************************* *** ****** *******************
TRANSMIT Number: R9800276 Amount: 580.1.9 05/04/00 11:02
Payment Method: CHECK Notation: MERIT MECHANICAL Init: TLB
Permit No: M99-0258 Type: B-MECH MECHANICAL PERMIT
Parcel No: 262304-9079
Site Address: 17300 SOUTHCENTER PY
Total Fees: 580.19
This Payment 580.19 Total ALL Pmts: 580.19
Balance: .00
Account Code Description Amount
000/345.830 PLAN CHECK - NONRES 116.04
000/322.100 MECHANICAL - NONRES 464.15
4099,05/08 97i7 TOTAL '580.19
Project:T2
Type of Inspection:
A 92
Date called: '
I
Special instructions:
Date wanted: �
f 1.
a.m.
p.m.
Requester:
Phone:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter B lvd, #100, Tukwila WA 98188
(206)431 -3670
pproved per applicable codes. fl Corrections required prior to approval.
COMMENTS:
El $47.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
Project: 3 e cat 144-
Type of iil do 4 n x
Address:
- -7-3 Sot/Overt-ter plyW
Date calle
i 02L/- O b
to wan d: �p
00 25 -O p
' '
Sp c' i ' stru
f (c OMMM pu tt r
)
Requester
PS 1 11 61a Se) 4
Phone:
,,N? 2S5 � /L/5q
INSPECTION NO,
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
ved per applicable codes.
i
0 z5
PERMIT NO,
(206)431 -3670
COMMENTS:
(b CtrS ( Alb 7
ipns required prior to approval.
$47.00 REINSPECTION FEE REQUIRED. Prior to inspectio , fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
COMMENTS: /
0 PRE PliqAt.-
047 ire-- / ?7 /J.;<( i7S
a / 4 /-263. /&( At 0 OA_
• - -a —f A f o (bv, A" ' 1 62f1 111e■•
4 T S 0 s pe. I DeA) Ce.f CI A
* f 047't rel 6) 7 e...
9 l'oi..5 9
D - C iteg-- / Af sn I c tc-ia, (2? U' //cfse,r72
cog C19-1.-(c )1_sAq - 7 - E_ 7 ea;),
( %X "4)
' cal
P.m.
Requester:
5hci ne-
-. A r /
_aniect:
Type Msp ction:
Address: iTh, i
17nDO . 81fili Cainler PY
Datp:,called:
6- .-0
/
Special instructions:
Dat wanted:
. n
' cal
P.m.
Requester:
5hci ne-
4 3 1e. " -- -- S3-
? 4
r
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
LI Approved per applicable codes.
lnsp
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
Dati
PERMIT NO.
(206)431-3670
Corrections required prior to approval.
$47.00 REINSPECTION FEE REQUIRED. Prior to inspecf ion, fee must be paid
at 6300 Soutlicenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No: '1
[—Date:
Prot t:
AC T (���
Type of Inspection:
H 11/1L s I - Do
Address:
Date called:
Special instructions:
Date wanted: . .
7
Requester C
Phone: •
INSPECTION NO.
CITY PERMIT NO.
TY OF TUKWILA BUILDING DIVISION
9818
INSPECTION RECORD
Retain a copy with permit '_ I '"
63 0 S outhcenter Blvd #100 Tukwila WA (206)431-3670
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
VIk 5 %'7
rui ti, s,�,4,57( H(
C $47.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
P
T Inspecti
p t:
A dr
D. ,..c
Specia`( instructions:
/7 od
Date aN 06
p.m.
Re rvStr: (
,�r7/
INSPECTION NO.
❑ Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
COMMENTS:
r/ /ice oo', 4& / it/o, 440
fi 4,64E‘,.5 '
/.c...(S Vc."4 -T*"
Date:
PERMIT NO.
(206)431 -3670
Corrections required prior to approval.
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:
Receipt No:
i
FINALAPP.FRM
City of Tukwila
Fire Department
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name `? .5 Zion5
Address 113104 57 ∎5 ∎LcA r( Q'l
Retain current inspection schedule
Needs shift inspection
Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm: �'h�rvhL
Hood & Duct:
Monitor: C.l1o QC, , rAro . Lt� A. is ?.. - LV,
Pre -Fire:
Permits:
Permit N
Authorized Signature Date
Steven M. Mullet, Mayor
Thomas R Keefe, Fire Chief
•
OA boo - 10(0
man - D2 5
Rev. 2/19/98 T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila. Washington 98188 • Phone: 206 -57S -4404 • Fax: 206 -S7S -4439
Space Heat Type
0 Electric resistance p All other (see over for definitions)
Glazing Area Calculation
Note: Below grade walls maybe included In the
Gross Exterior Wall Area if they are insulated to
the level required for opaque walls.
Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1.
(rough opening) Gross Exterior
(vertical & overhd) divided by Wall Area times 100 equals % Glazing
480.0 — 17280.0 X 100 = 2.8
Concrete/Masonry Option
QQ yes Check here if using this option and if project meets all requirements for the Concrete/Masonry
Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying
Q no assembly below.
Project Info
Project Address >t..t soy
Minimum Insulation R- values
Roofs Over Attic
Date 12/7/99
Parkway Super Canter
24.0
Opaque Walls
For Building Department Use
?ukwilla, WA
Below Grade Walls
Applicant Name: Mulanny architect.
Slabs -on -Grade
Applicant Address: 222 SW Columbia, at. 1250,
Portland,
OR
97201
Applicant Phone: (so) 223 -9351
Maximum U- factors
Opaque Doors
Envelope Requirements (enter values as applicable)
Fully heated/cooled space
Minimum Insulation R- values
Roofs Over Attic
All Other Roofs
24.0
Opaque Walls
Below Grade Walls
Floors Over Unconditioned Space
Slabs -on -Grade
10.0
Radiant Floors
Maximum U- factors
Opaque Doors
0.600
Vertical Glazing
0.650
Overhead Glazing
Maximum SHGC (or SC)
Vertical/Overhead Glazing
1 1.300
Climate Zone 1
ENV -SUM
1997 Washington State Nonresidential Energy Code Compliance Foam
[project Description
L°
New Building 0 Addition
❑ Alteration ❑ Change of Use
Compliance Option
Prescriptive 0 Component Performance
(See Decision Flowchart (over) for qualifications)
ENVSTD 0 Systems
Analysis
Semi- heated space'
Minimum insulation R- values
Roofs Over Semi- Heated Spaces'
'Refer to Section 1310 for qualifications and requirements
Notes:
C
1997 Wash m State Nonresidential Energy Code Comp! .e Form
RECENED
CITY OF TUKWiLA
EC, 2 8 1999
PERMIT CENTER
First Edtlon,.Axte 1999
Opaque Concrete/Masonry Wall Requirements
Insulation on interior - maximum U- factor is 0.19
Insulation on exterior or integral - maximum U- factor is 0.25
If project qualifies for Concrete/Masonry Option, list walls
with HC z 9.0 Btu/ft•°F below (other walls must meet
Opaque Wall requirements). Use descriptions and values
from Table 20 -5b in the Code.
Wall Description
(Including insulation R -value & position)
12'CM0 wall with integral inaulati
U- factor
0.250
M99 O
Weight:
CHECK ONE:
Wall x
Roof
Floor
Sketch of
Construction Assembly
LB /SF
Roof Color: Light /Medium
(Dark Color is not Recommended)
Best Buy Wall
U -Value Calculation
1. Foam Filled 12" CMU 3.1
Grouted Steel 40" o.c. (From ASH RAE)
2.
3.
4.
5.
6.
7.
8.
List of Construction Components
Inside Surface Air Film
Outside Surface Air Film
Total Resistance FIT
U -Value (1 /R
0.68
0.17
3.95
0.253165
Architect:
Signed:
Date:
Project Info
Project Address Hest Huy
Date 12/6/99
South Center Parkway
For Building Department Use
Tukwila, NA
Applicant Name: s teffeni. May LIMA A Associates
Applicant Address: 222 SW Columbia Street Suite 1275
Applicant Phone: Portland, Oregon 97201
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
sack of building
Type 'W', 400 Watt Metal Halide Wall bracket
6
480.0
2880.0
Building Front
Type 'HD', 100 Watt Meaal Halide Wall Bracket
14
112.0
1568.0
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2 ..
Area in ft
Allowed x Area
Sales floor
Retail •s• (Footnote 10)
1.62
46021.0
74554.0
Office /RR
Type 'FM 2x4 Recessed Troffer with Emergency Ballasr
7
114.0
798.0
Receiving
Type 'Fe4' 4' Fluorescent Strip
1
62.0
62.0
" From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
74554.0
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Office /RR
Type 'TO' 2x4 Recessed Troffer
13
114.0
1482.0
Office /RR
Type 'FM 2x4 Recessed Troffer with Emergency Ballasr
7
114.0
798.0
Receiving
Type 'Fe4' 4' Fluorescent Strip
1
62.0
62.0
Elec. Room
Type 'FHB' 8' Fluorescent Strip
2
114.0
228.0
Entrance
Type 'FE4' 6•X4' Recessed Troffer
14
62.0
868.0
TV Sales
Type 'FW' Wall Washer
8
31.0
248.0
Sales Floor
Type 'HA' 400 W Metal Halide High Bay
123
461.0
56703.0
Sales Floor
Type 'HS' 400 W Metal Halide High Bay with Restrike
22
461.0
10142.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
70531.0
Location
Description
Allowed Watts
per ft or per If
Area in ft
(or If for perimeter)
Allowed Watts
x ft (or x If)
Covered Parking
0.2 W /ft
Open Parking
0.2 W/f 2
Outdoor Areas
0.2 W /tt
Bldg. (by facade)
0.25 W /ft
Bldg. (by perim)
Length of Front and Back of Building
7.5 W /If
596.0
4470.0
Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts
4470.0
Lighting Summary
LTG -SUM
1997 Washington State Nonresidential Energy Code Compliance Forms
1997 Wash In State Nonresidential Ener.y Code Complir 3 Form
First Edition • June, 1998
Project Description
New Building ❑ Addition
❑ Alteration
Compliance Option
Alteration Exceptions
(check appropriate box)
0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
❑ No changes are being made to the lighting
Maximum Allowed Lighting Wattage (Interior)
❑ Less than 60% of the fixtures are new, and installed lighting wattage is not being increased
ballasts only, the default table in the NREC Technical Reference Manual may also
Proposed Lighting Wattage (Interior) be used.
Maximum Allowed Lighting Wattage (Exterior)
Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only,
Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
1997 Washl( n State Nonresidential Energy Code Com j Form
1 1
Total Proposed Watts may not exceed Total Mowed Watts for Exterior Total Proposed Watts
4448.0
tie
LPA
(Wm)
Use'
LPA
(W/ft
Paining, welding, carpentry, machine shops
a3
Police and fire stations
1.2
Barber shops, beauty shops
2
Atria (atriums)
1
Hotel banquet/conference/exhibition haI '
2
Assembly spaces', auditoriums, gymnasia ° , theaters
1
Laboratories
2
Process plants
1
Aircraft r =•air hangars
1.5
Restaurants/bars
1
Cafeterias, fast food establishments'
1.5
Retail A
1
Factories, workshops, handling areas
1.5
Retail B Retail banking
1.5
0,8
Gas stations, auto repair shops
1.5
Locker and /or shower facilities
Institutions
1.5
Warehouses ", storage areas
0.5
Libraries'
1.5
Aircraft sbrage hangars
0.4
Nursing homes
1.5
Parking garages
s«Seclon 1532
Wholesale stores (pallet rack shelving)
1.5
Mall concourses
1.4
Plans Submitted for Common Areas Only'
0.8
Schools buildings, school classroom, daycare centers
1.35
Common area, corridors, lobbies (except mall concourse)
Laundries
1.3
Toilet facilities and washrooms
0.8
Office buildings, office/administrati',e areas in facilities of
other use types (including but not limited to schools,
hospitals, institutions, museums, banks, churches)
1.2
Prescriptive Spaces
Occupancy:
0 Warehouses, storage areas or aircraft storage hangers *Other
Qualification Checklist
Note: If occupancy type is 'Other' and fixture
answer is checked, the number of fixtures in
the space is not limited by Code. Clearly
indicate these spaces on plans. If not
qualified, do LPA Calculations.
Lighting Fixtures:
❑ Check here if at least 95% of fixtures in the space meet all four criteria:
1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and
2. Lamps are T -5, T•6, T -8 or PL, and 3. Lamps are 5 -50 Watts, and
4. Ballasts are electronic ballasts
1997 Washington State Nonresidential Energy Code Compliance Forms
1997 Wash to State Nonresidential Enersy Code Compl' a Form
Lighting Summary (back)
LTG -SUM
Table 15 -1 Unit Lighting Power Allowance (LPA) for Interior Lighting
First Edition • June, 1998
Footnotes for Table 15-1
1. In cases in which a use is not mentioned specifically, the Unit PowerAlloKnnce shall be determined by the building official. This
determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas.
2. The watts per square foot may be increased by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
3. Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4. For all other spaces. such as seating and common areas, use the Unit Light Power Allowance for assembly.
5. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6. Includes pump area under canopy.
7. In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for
usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area
and rest rooms. Common areas, as herein defined do not include mall concourses.
8. For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot.
9. For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per
square foot.
10. For both Retail A and Retail B, light for free - standing display, building showcase illumination and display window illumination installed
within two feet of the window are exempt.
Retail A allows a Unit Lighting Power Allowance of 1.0 watts per square foot. Ceiling mounted adjustable tungsten halogen and HID
merchandise display illuminaries are exempt.
Retail B allows a Unit Lighting Power Allowance of 1.5 watts per square foot, including all ceiling mounted merchandise display
luminaries.
11. Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area.(access side only)
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks.
1997 Washington State Nonresidential Energy Code Compliance Forms
y Code Compl( a Form
Lighting Power Allowance Adjustments
LTG -LPA
1997 Wash in State Nonresidential Ener
First Edition • Jun., 199E
Project Address IB.■t Buy
rate
12/6/99
Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The
Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet,
12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts
per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM.
Adjusted Lighting Power Allowances (Interior)
Location
(floor /room no.)
Salem Floor
Occupancy Description
Retail a
Allowed Ceiling Height Ceiling Height limit Adjusted LPA
Watts per ft " for this room for this exception" Watts per ft
1.50 24.0 feet 20 feet
1.62
From Table 15 -1 based on exceptions listed In footnotes
Lighting Permit Plans Checklist LTG -CHK
1997 Washington State Nonresidential Energy Coda Compliance Forms Find Edition - June, 1996
Project Address Rest 3W
Date 12/6/99
The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the
1994 Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
!Component
!information Required
I Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
'Local control/access
Schedule with type, indicate locations
yes
1513.2
Area controls
Maximum limit per switch
n.a.
1513.3
Daylight zone control Schedule with type and features, indicate locations
n.a.
vertical glazing
Indicate vertical glazing on plans
n.a.
overhead glazing
Indicate overhead glazing on plans
yes
1513.4
Display /exhib/special
Indicate separate controls
1513.5
Exterior shut -off
Schedule with type and features, indicate location
yes
(a) timer w/backup
indicate location
yes
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off Indicate location
no
1513.8.1
(a) occup. sensors
Schedule with type and locations
yes
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability);
indicate size of zone on plans
yes
Lighting Sum, Form
Completed and attached.
Schedule with fixture types,
lamps, ballasts, watts per fixture
yes
Eiec motor efficiency
MECH -MOT or Equipment Schedule with hp, rpm, efficiency
1997 Was an State Nonresidential Energy Code Comp as Form
If "no" is circled for any question, provide explanation:
1513.6.1 Occupancy Sensors: Occupany Sensors are not used due to the use of Automatic
Controls and a full Energy Management System.
Lighting - General Requirements
1513 Lighting Controls
1513.1 Local Control and Accessibility: Each space,
enclosed by walls or ceiling-height partitions, shall be protAded
with lighting controls located within that space. The lighting
controls, whether one or more, shall be capable of turning off
all lights within the space. The controls shall be readily
accessibe, at the point of entry/exit, to personnel occupying or
using the space.
Exceptions: The following lighting controls may be
centralized in remote locations:
1. Lighting controls for spaces which must be used
as a whole.
2. Automatic controls.
3. Controls requiring trained operators.
4. Controls for safety hazards and security.
1513.2 Area Controls: The maximum lighting power that may
be controlled from a single switch or automatic control shall not
exceed that which is provided by a twenty ampere circuit
loaded to not more than eighty percent. A master control may
be installed provided the individual switches retain their
capability to function independently. Circuit breakers may not
be used as the sole means of switching.
Exceptions:
1. Industrial or manufacturing process areas, as
may be required for production.
2. Areas less than five percent of the building
footprint for footprints over 100,000 ft
1513.3 Daylight Zone Control: All daylighted zones, as
lefined in Chapter 12, both under overhead glazing and
adjacent to vertical glazing, shall be provided with individual
controls, or daylight- or occupant - sensing automatic controls,
which control the lights independent of general area lighting.
1513.4 Display, Exhibition, and Specialty Lighting
Controls: All cisplay, exhibition, or specialty lighting shall be
controlled independently of general area lighting.
1513.5 Automatic Shut -off Controls, Exterior: Exterior
lighting not intended for 24 -hour continuous use shall be
automatically switched by timer, photocell, or a combination of
timer and photocell. Automatic time switches shall also have
1997 Washi i State Nonresidential Ener Code Corn' li :; Form
Lighting Permit Plans Checklist
1997 Washington State Nonresidential Energy Code Compliance Forms
LTG -CHK
First Edition • June, 199E
program back -up capabilities, wi9ch prevent the loss of
program and time settings for at least 10 hours, if power is
interrupted.
1513.6 Automatic Shut -Off Controls, Interior: Office
buildings greater than 25,000 ft and all school dassrooms
shall be equipped with separate automatic controls to shut off
the lighting during unoccupied hours. Automatic controls may
be an occupancy sensor, time switch, or other device capable
of automatically shutting off lighting.
Exceptions:
1. Areas that must be continuously illuminated, or
illuminated in a manner requiring manual
operation of the lighting.
2. Emergency lighting systems.
3. Switching for industrial or manufacturing process
facilities as may be required for production.
1513.6.1 Occupancy Sensors: Occupancy sensors shall be
capable of automatically turning off all the lights in an area, no
morethan 30 minutes after the area has been vacated.
1513.6.2 Automatic Time Switches: Automatic time switches
shall have a minimum 7 day clock and be capabe of being set
for 7 different day types per week and incorporate an automatic
holiday "shut -off" feature, which turns off all loads for at least
24 hours and then resumes normally scheduled operations.
Automatic time switches shall also have program back -up
capabilities, which prevent the loss of program and time
settings for at least 10 hours, if power is interrupted.
Automatic time switches shall incorporate an over -ride
switching device which:
a is readily accessible;
b. is located so that a person using the device can see
the lights or the areas controlled by the switch, or so
that the area being illuminated is annunciated;
c, is manually operated;
d. allows the lighting to remain on for no more than two
hours when an over -ride is initiated; and
e. controls an area not exceeding 5,000 ft or 5 percent
of footprint for footprints over 100,000 ft whichever is
greater.
ACTIVITY NUMBER: M99 - 0258
Response to. Correction Letter # _
DATE: 12 -28 -99
PROJECT NAME: PARKWAY SUPERCENTER -BEST BUY
XX Original Plan Submittal Response to Incomplete Letter #
Revision # _ After Permit Is Issued
DEPARTMENTS:
KEW
B ilding Division
4 1,�C 2- Il -,wOO
Public Works n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
TUES /THURS ROUTING:
Please Route
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Incomplete
Structural Review Required
REVIEWERS INITIALS:
APPROVALS OR CORRECTIONS: (ten days)
Approved n Approved with Conditions
REVIEWER'S INITIALS:
CORRECTION DETERMINATION:
Approved n Approved with Conditions
\PRROUTE,DOC
5/99
Iz
Fire Prevention
12-,0
Structural n
Planning Division
Permit Coordinator
DUE DATE: 12 -30 -99
DUE DATE
Not Applicable
Ti No further Review Required
DATE:
DUE DATE 1 -27 -2000
Not Approved (attach comments) n
DATE:
Not Approved (attach comments)
REVIEWER'S INITIALS: DATE:
n
r-i
City of Tukwila
Fire Department Thomas P. Keefe, Fire Chief
Fire Department Review
Control #M99 -0258
(512)
Re: Best Buy - 17364 Southcenter Parkway
Dear Sir:
December 30, 1999
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. H.V.A.C. units rated at greater than 2,000 cfm require
auto - shutdown devices. These devices shall be separately
zoned in the alarm panel and local U.L. central station
supervision is required. (City Ordinance #1742)
H.V.A.C. systems supplying air in excess of 2,000
cubic feet per minute to enclosed spaces within
buildings shall be equipped with an automatic shutoff.
Automatic shutoff shall be accomplished by
interrupting the power source of the air - moving
equipment upon detection of smoke in the main
supply -air duct served by such equipment. Smoke
detectors shall be labeled by an approved agency for
air -duct installation and shall be installed in
accordance with the manufacturer's installation
instructions. (UMC 608)
Dedicated fire alarm system circuit breaker(s) shall
be equipped with a mechanical lockout device. (NFPA
72 (1- 5.2.8.2))
Duct smoke detectors shall be capable of being reset
from the alarm panel. (City Ordinance #1742)
Local U.L. central station supervision is required.
(City Ordinance #1742)
Remote indicator lights are required on all above
.. .. ... • _ •• - V---- " --` -- nn inn _ n. _ _ _ ,w,,,, ....- ,As •
John W. Rants, Mayor
1•.
Yours truly,
City of Tukwila
Fire Department
Page number 2
ceiling smoke detectors. (City Ordinance #1742)
All new fire alarm systems or modifications to
existing systems shall have the written approval of
The Tukwila Fire Prevention Bureau. No work shall
commence until a fire department permit has been
obtained. (City Ordinance #1742) (UFC 1001.3)
Call the Tukwila Fire Department at 575 -4407 for
approval of any system shut down. Have job site
address, name and the Tukwila Fire Department Job
Number available to confirm shut down approval. (City
Ordinance #1742)
Contact The Tukwila Fire Prevention Bureau to witness
all required inspections and tests. (UFC 10.503)
(City Ordinance #1742)
2. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
3. This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
The Tukwila Fire Prevention Bureau
cc: TFD fle
ncd
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
F(2 4152. N 11 (N/97)
(-2
DEPARTMENT OF LABOR AND INDUSTRIES
REGIST. # EXP. DATE
CCO1 MERITMI163CM 04/01/2001
EFFECTIVE DATE 02/14/1984
MERIT MECHANICAL INC
PO BOX 2109
REDMOND WA 98073 -2109
I certify that this is a true and correct copy of an original license.
REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
Notary Public in and for the State of
Washington residing in Redmond.
Best Buy Co. Contacts
REAL ESTATE MANAGER:
Ben Moore / Tom Gyulay
(612) 995 -7869
BBC ARCHITECT:
Jackolyn Cook -Haxby
(612) 995 -7015
STORE PLANNER:
John Spray Jr.
(612) 995-7276
PROJECT MANAGER:
Dick Simmons
(612) 963-0858
CONSTRUCTION MANAGER:
Corky Berg
(612) 995 -7231
FIXTURE SPECIALIST:
Mick McGrorty
(612) 995 -7748
Architect
MULVANNY ARCHITECTS
KOIN Center
222 SW Columbia, # 1250
Phone: (503) 223 -8030
Fax: (503) 223 -8381
EMAIL: brianr @mulvanny.com, jessicac @mulvanny.com
Contacts:
Brian Roberts, Jessica Coyle
Structural
Tim R. Froelich Consulting Engineers, Inc.
6969 SW Hampton Street
Tigard, Oregon 97223
Phone: (503) 624 -7005
Fax: (503) 624-9770
EMAIL: fcetigrd @teleport.com
Contacts:
Faramarz Dindar - Azimi, P.E. (Dean)
BEST BUY / PARKWAY SUPERCENTER
Vicinity Map
To
RENTON
l Mechanical / Electrical
LIMA and Associates Inc.
222 S.W. Columbia, Suite 1275
Portland, Oregon 97201
Phone: (503) 295 -4995
Fax: (503) 295-0503
EMAIL: limainc.com
Contacts:
Mechanical: Greg Nelson
Plumbing: Don Parrish
Electrical: Steffenie May
General Notes
1. ECECHICALPANII$ ERE EXPCi .L CABL,S,E C LOCADEONRATDEDFAETTLEMN.ALI.
BACKED WITH DRYWALL. RF R3EDTO]LAITAN RAMC OL. ALIGRID%E YWAL'E
TFJCKNESS REQLTdD FDRAL�J TREAL ?ANTES, FIREMNGLICA2E.5, E6C
I PROVIDE DOUBLE - SiEDS,BIDC tNG BRACINGANDRACK *PP:AiESMY.EfER3kTR:DT05, J
EQUIPMENT, MISCETTANTEMSTttx_TE,T1FICA.• CA_SWr03K.CABENT - G3AHM ,TFL
ACCFSSORESETC.
3. ALL COLUMN INES ST OWNOYFICQR PLANS WBi' FLAW COb W: FLN - ffa .ERILIWNUN
THEM. THESEBLBBLES AREtDR.E Ea CCEIANSAL.LABEHEIED ON n 5"CF3._AL
DRAWINGS
4. DO NOT SCALE DRAWING. IF DNA[FNIONS_AREN QG - L-iir . IBECO `T3,ACHIR.SH:LTLEE2E
FOR OBFALN'NGUAEICAIDSFROM OWlERSRE= L-a— TATLVEH -CONTIN�KWITH
CONSTRUCTION.
5. CO\TRACIORSHAILV .DRIEWON.E.A.COORMiAT`. ALL ADFE
6. CONTRACTOR SHAT? VFd.',...EQUIPI.TFACA IONS/CODBEE.CINSANDREQLRDC,I= RANNCIS
OF. EQUH to,. iTEaEICATIONS.. NDEI e7PY NTKANLLS�Q,T
i.. ALL SYN BOTS,ABBREV ATRNS ANTI NOTES MARKF ]`IYEEM70R'EYP- `S.. AMY NALI. AR
CIRCCMSTANC6.CNT.OTIO WIE- NUTED-
S. 1htStDR.ASO.DONOTCONTAIIN rr 411 ` , II M
PROCEDLBE THE CONTRAC[ORIS'a.?N E FOR AIL aX RLrLG=iv?E?Y- a_.+SEMI.B??�
ALL WORKNACCOMANCEWTIHSIATEANWORFEIERALC4NSIRLr iSAEE.Z GTiIDETTII:<
9. THESE DR.AWNGSARE nn FROPERT:OF85CBLKCORR NOCHANNCESTOTHEEDOC IN.Ti _dh
N *HUE ORNPART -MAY ZHADEWITHOC tT. TENSE is 4?0Tru[i =NLDN .NTOE See
NDRTDI;ALABOENAMEAND SHNATEEAPPFAIECKNTHEDOCLIIENTE
Scope Of Work
THE SCOPEOF WORK CON COANDRELON OF ANEW ERTFDNGPOK7ON WT[E'.LNAN
ECRU. SHOPPING CENTER ONA PAD PREVIOUSLY PREPAREDFORCON TRULTON_
ALSO NCLUDED APE ALL TENANT TSLPROVEMSNFS FORAB>r BLYSTOR _
WORK INCLUDES; CMLU. SUMMAND DEMTSNG WALES, REINFORCED CONCRETE FOOTING, METAL
FRAME CANCATES, WS. FACADE SNGLE PLY RO DENG., SAL DECKING, STEEL BAR JOISTS, BEAMS .AND
CO`.€]INS.P1.L NEW Pr_.iMBNG. 3ECHANTCAL& ELECTRICALST'STF AND CON,C- EONS ARE TO BE
PROVIDED.
TUKWILA, WA.
Abbreviations
ACOIE
AFE-
AGGR.
A_.Lx
ANOD.
APPROti
ARGI
ASPH
BD.
BLDG.
BLK
Bt %v.
EL, T.
RU 3.
CAB.
CB.
CEti
CI.
G.G.
CLR
Co.
COL
CONC.
CONN.
CONNTR
CON:.
CT.
DBL
DEPT
DEL
DLL
DIAL
DN.
D3
DS.
DWG.
E4
EL`-S.
EL
EEC
ENCL
EP.
A.
ANGLE
AT
CENTERLINE.
DIAMETER OR
ROUND
PERPENDICULAR
POUND OR NUMBER
.ANCHOR BOLT
ACOUSTICAL
ABOVEANTSH FLR
AGGREGATE
i.I.LMLN'I;M
ANODIZED
APPROXIMATE
ARCHITECTURAL
ARSIALT
BOARD
BUILDING
BLOCK
BLOCICNG
BEAN
BOTTOM
BELT UP ROOF
CABINET
CATCH BASIN
CH N3a
CEILNG
CLEAR
CLEAN OLT
COLUMN
CONCRETE
CONNECTION
A CONSTRUCTION
'GONINTIOUS
CERAMIC THE
CENTER
COL,. SINK
DOUBLE
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DOWN
DOOR
DOWNSPOUT
DRAWING
E4 T
EACH
EXTEWA INSULATION
EMIT SYSTEM
EOANSION TOW
ELEVATION
ELECTRICAL
ELEVATOR
ENCLOSURE
ELECTRICAL PANE.
EQ.
EQUIP.
EXIST.
F.O1C.
FD.
F.E.
F.H.
FN.
F1 ASH
PLR
FLUOR
FOUND.
FRAM.
FT.
FIG.
FURR
GA.
GAL,
G.C.
GL.
GND.
GR.
GP.
G.W.H.
GYP.
BDWE
HDCP.
HDWD.
H.H.
RC.
H-VL
How..
HR
HE
INST.
NSUL
NT.
LAM.
LB.
IOC.
WAIL.
MAX
MFR
NH.
MECH.
MIN.
MISC.
MEL
N.[.c.
N0.
N.T.S.
I understand that the Plan Check approvals are
uLdect to errors and omissions and approval of
p lans does not authorize the violation of any
I adopted =ode or ordinance- Receipt of con -
ILartDrsno„ofapproved f - iii ack,owiedged
By
EQUAL
EQUIPMENT
EXISTING
EXPOSED
EXTERIOR
FURNISHED BY OWNER
INSTALLED BY CONTR.
FLOOR DRAIN
EREEXTNG-
LISHER
FIRE HYDRANT
KNISH
FLASHING
FLOOR
FLUORESCENT
FOUNDATION
FRANNG
FOOT OR FEET
FOOTNG
FURRING
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GLASS
GROUND
GRADE
GROUP
GYPSUM WALL
BOARD
GYPSUM
HARDWARE
HANDICAP
HARDWOOD
HOSE BIBB
HOLLOW CORE
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
INSTALLATION
INSULATION
NTERIOR
LAMINATED
POUND
LOCATION
MATERIAL
MAXIMUM
MANUFACTURER
MLANHOLE
MECHANICAL
MINMLNI
MISCELLANEOUS
MOUNTED
METAL
NORTH
NOT N CONTRACT
NUMBER
NOT TO SCALE
O.C. ON CENTER.
01 OfER
OPP :GSTE
PL. PLATE
PLY D. PLYWOOD
P.P. POWER POLE
PLAN PLASTIC LAMIINATE
RD.
REF.
RENT.
READ.
RN_
S.C.
SCHED
SLIT.
SLIM.
SIN.
SPEC.
SQ.
STD.
STL
STOR
sTRCC.
SUSP.
S.8 V.
SVC.
SAM.
S/W
T.
T.C.
TEL
T.A G.
THK
T.O.P.
T.P.
T.W.
TAP.
VERT. VERTICAL
W.
W/
WD.
WDW.
W/o
W.r.
W.R.
WSCT.
WT.
RADIUS OR RISER
ROOF DRAIN
RECOMMENDED
REFERENCE
RENTORCED
REQUIRED
ROOM
SOUTH
SOLID CORE
SCIEDULE
SHEET
SHEATHING
SMEAR
SPECIFICATIONS
SQUARE
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
STAN. VARNISH
SERVICE
SYMMETRICAL
SIDEWALK
TREAD
TOP OF CURB
TELEPHONE
TONGUE AND GROOVE
THICK
TOP OF PLATE
TOP OF PAVEMENT
TOP OF WALL
TYPICAL
L'.B C. UNIFORM HUILDNG
CODE
INT. UNFINISHED
U.ON . UNLESS OTHERWISE
NOTED
WEST
WITH
WOOD
WINDOW
WITHOUT
WATERPROOF
WATER RESISTANT
WAINSCOT
WEIGHT
Sheet Index
CS -1 COVER SHEET
Architectural
AS -1 ARCHITECTURAL SITE PLAN
A -0 EXIT & EGRESS PLAN
A -1 FLOOR PLAN
A -2 ENLARGED FLOOR PLANS
A -3 FLOOR COVERING PLAN
A -4 REFLECTED CEILING PLAN
A -5 ROOF PLAN
A -6 EXTERIOR ELEVATIONS
A -6.1 EXTERIOR ELEVATIONS & OVERALL SECTION
A -7 INTERIOR ELEVATIONS
A -8 WALL SECTIONS
A -9 WALL SECTIONS
A -9.1 WALL SECTIONS
A -9.2 WALL SECTIONS
A -10 PLANS & ELEVATIONS AT STOREFRONT
A -11 DETAILS
A -12 DETAILS
A -13 DETAILS
A -34 DETAILS
Fixture Plans
F -1 FIXTURE PLAN
F -2 ENLARGED MILLWORK PLANS
Structural
S -0 STRUCTURAL NOTES
S -1 FOUNDATION PLAN
S -2 ROOF FRAMING PLAN
S -3 FOUNDATION DETAILS
S-4 FRAMING SECTIONS & DETAILS
S -5 FRAMING SECTIONS & DETAILS
Mechanical
M -1 HVAC ROOF PLAN
M -2 PLUMBING FLOOR PLAN
M -3 ENLARGED PLUMBING PLANS & DETAILS
M-4 HVAC FLOOR PLAN
M -5 HVAC ELEVATIONS
M -6 MECHANICAL DETAILS
M -7 MECHANICAL DETAILS
M -8 MECHANICAL DETAILS
Electrical
E -1 ELECTRICAL LIGHTING PLAN
E -2 POWER PLAN
E -3 ELECTRICAL LOW VOLTAGE FLOOR PLAN
E-4 SECURITY SYSTEM LAYOUT
E -5 PANEL BOARD SCHEDULES AND RISERS
E -6 ELECTRICAL LEGENDS AND SCHEDULES
E -7 ELECTRICAL DETAILS
E -8 ELECTRICAL DETAILS
EM -1 EMS NOTES & SCHEDULES
EM -2 EMS DIA
C -1 COVER SHEET
C -2 PRELOAD/ T.E.S.C. PLAN
C -3 GRADING & STORM DRAINAGE PLAN
C-4 SANITARY SEWER & WATERMAIN
C -5 NOTES & DETAILS
C -6 PRELOAD/ T.E.S.C. PLAN
Revisions
A\ tt '*.t.9 PIPM IT APPLAGATIoN
f$ioi6M14s4tom *1
ne)44
CITY OF T'„ V8N1 A
VC
APPftn�: ED
a DMQ
RECEIVED
CT,y CF NKN'ttA
PERIM CENT.
1199 -o
Q �Y
4t
ONMaVd O
AFE
3a• Ecrgss 1 1
T T`' — —T
6
b j S AREA
bYt�CL3 NDICgTE
Firms IXIT 51C3dbl TTP.
VESTIBULE
O EXIT EGRESS PLAN
SCALE: 3/322 • = 1' -0'
4.4
A. V-N
I. Applicable Codes:
A. Building: 1997 UBC with Washington Amendments
B. Plumbing: 1997 UPC with Washington Amendments
C. Mechanical: 1997 Washington Mechanical Code
D. Electrical: 1996 NEC
E. Fire:
F 1997 Washington State Energy Code
G. Adoessiibility: ADA
H. Occupancy T
A. Sales Area - M (mercantile)
B. Accessory Sales (Stereoliisla)I) - S3 (garage install) XI. Plumbing Fixture Analysis
C. Storage /Stack/Receiving/Remaining - Si (storage) A. Building Occupance for Plumbing Calculations
HI. Construction Type
B. Structural Fire Ratings
Non Rated
IV. Fire Suppression System
V. Building Height & Area
A. Height
1. Allowable - Two Story
2. Actual Height - One Story
VI. Building Area
A. Sated Area
B. Accessory Sales (Stereo Install)
C. Storage /Stacic/Shipping/Remaining
- - " - V ITTOcctt`piSSFLoad --- - _�
A. Sales Space(30) - 1302
B. Accessory Sales (Stereo Install)(30) - 39
C. Storage/Stack/Shipping/Remaining(300) - 19
D. Total Occupants - 1360
VIII. Exit Capacity (sales space)
A. Number of Exits Required four
B. Number of Exits Provided four
C. Egress Width Required 261"
D. Egress Width Provided 282"
0
- 39,062 S.F.
- 1.152 S.F.
- 5,670 S.F.
45,884 S.F.
IX. Arrangements of Exits
A. Diagonal -310 Feet
B. Furthest Distance Between Exits -181 Feet >1/2 dia.
C. Maximum Travel Distance -175 Feet
X. Other Life Safety Considerations
A. Corridor Width - 48 inch min.
B. Dead End Corridor - 12' -6"
C. Exit Width (1F.C. emergency light) - 44"
1. Occupant Load
45,883 / 200 = -230 occupants
2. Minimum Facilities Required
a. Men
2 - Lavatories
2 - Water Closets
1 - Urinals
b. Women
2 - Lavatories
3- Water Closets
c. Drinking Fountains
1 - Drinking Fountains (handicap accessible)
AFFR.
FEB )r 200
at
ad
Q z
3a�
z3
a U at
PERMIT SET
12/08/99
rev. date
A
A
A
A
A
nECEIVEO
CRY OF TUKYdILA
PERMIT CENTER
SCALE:
3/32" = 1' -0"
EXIT & EGRESS
PLAN
A -0
2`x24' IN -WALL PILASTER
9 GIRDER LOCATION (TYP -)
SEE DT, 10/S3 FOR RELNE
.;5N'35K
2,200 _B5
%2,200 LBS
OG1N'3.0K
TY ?. e RT= OPENINGS
-SEE NOTES T 5 AND
SPA GFS =NOIIF� ('.,.J. ./
G <x20� UINDERJ
p' ST'uDI:lA1_L
3.5.1N12 R.
36,N12,,
36G7.1.ZK
C
0'
2'x24' IN -WALL °ILAST
5
GIRDER LOCATION (TT ?)
SEE DTL 0/S3 FOR REIN =.
I .Lj
2200 Las
/ —SEE NOTE 6 (TYP.I
6G-1N12P1K
SPACES 5'^' N
6G1N12 0‹
AGE AT 5 5 •
c'EAT: Eta Tti- W ¢
r..
566-1,72.2 K
24C53N135K
00
24G3NI35K
n
3 S ?ACES AT 6' -2
= 16' -6•
\__EXIST. CMU PIER
r FRAMING FLAN
SCALE: 3/32' =1' -0' --
311.099
0 TTP CNN e
SEE SECTION CUTS
FOR CANOPY ROOF
e CEILING FRAMING
Y
ROOF CANOPY FRAMING PLAN
W16
SCALE= 3/32' =1' -0'
311Pl -99
26
SIM
AGES SHOWN
KNORR 500EJI6
I6• O.G. W / PLYLPD.
REF. NOTE 14.
TYP
Y
ACI
� OPENING IN LOIIF_R LII0zi5� _5 55 -
CANOPY
[JIP501. 11111411111V.1111 � �-Ilrlii��►�1� iiii� �� I � ,N, WI0xl5 !'' WIOxI UR {x55 (CAW'0.15 I5 °° x `,� — �1a11111�1111��IIH I. 01.,22 5 WI6zL'o -
TS SxSzl�a ON CMU PIER /
TO SUPPORT STEEL `LINE OF OVERHANGING L"'P GORNE.'vs
BEAMS ABOVE. ROOF ABOVE.
Ilkdk
SEE DTL. 1/55, SEE NOTE F2.
NDICA -S SEA,
TOP OF CI, WALL
-TY, SEE D- AILS_
SEE SECTION CUT FCR
CANOPY ROOF S CLG.
51M
12'x24' IN -WALL ?FLA - TER
END OF WALL. REIN.. PER
DTL. i0 /53.
L3+c3x3 /I6' e ; I�
PANEL POINTS \ I
I MIN
3 %6 "x3 SHO BENT P
A „
L3x3x3 /I6` BRACING m O' O.C.
W /(I) 345 M.B. m EA. END. TYP
NOTE: PROVIDE ADDITIONAL
3
NT: PIPE SUPPO, SYSTEM a ALL CONNECTIONS FROM 4o PIPE <T1AXJ
12'x24' IN - WALL PILASTER FIRE SPRINKLER SUBCONTRACTOR TO BE RE VIEWED
^+�
GIRDER LOCATION (TT,/ a APPROVED PRIOR TO CONSTRICTION
SEE DTL 10/53 FOR REINF.
iY?
EXIST. BLDG LINE
—EY. S CMU PIER
SPRINKLER CONN_ DETAIL
C
SALE: 1'=1'-0'
311ID -99
SCALE: 1' =1' -0
3110 -99
it
WHERE � e P IPE
DIRECTION. SEE DT.
MORE INF
SPRINKLER CONN, DETAIL
Roof Plan Notes
S2
I. VERIFY ALL DIMENSIONS AND ELEVATIONS WITH THE ARCHITECTURAL DRAWING -5.
DETAILS ON THESE PLAN A= INTENDED N DEPICT THE GENERAL CONS 70 u -F ION
MET FOR THIS ST CONIJE GTIONS, DETAIL AND CONDITIONS NOT
SPECIFICALLY SHOLLN THGT ARE SIMILAR TO 1 THAT ARE SPECIFIED SHALL
BE ASSUMED ONE AN THE , NOTIFY IF THE C R' / ENGINEER THE APPLICATION
C.
CLARIFICATION DETAILS ARE I N A TAMELY , NOTIFY THE ARCHITECT / ENGINEER FOR THE
CL4RIFICATIGN iN G TIMELY MANNER PRIOR TO BID OPENING -.
JOIST SUPPLIER IS TO OSHA PROVIDE BRIDGING THAT MEETS ALL JOIST DESIGN, STEEL
JOIST INSTINTE AND REOIJIREMENTS.
a. THE TWO GIRDERS OVER THE ENTRANC � THE TORE (Ai GRID LINE 6 WILL BE
pE51GNED WITH A 4.' LIVE LOAD DEFL'EJJN' LIMSIT. ,e-c LIVE LOAD ON THESE
GIR IS l0% OF THE TOTAL LOAD.
ALL JOISS J 01 GIERS AND BRIDGInG WILL BE DE5IGND FORA N UPL
FROM WIND L ]T 5 T t.F RD AT CORNERS AND OVERHANGS 12 PS ELSEWHE2ET
o. J OIST G GNED RS LOCATED UNDER ROB TOP :NITS (RTU'SJ SHALL BE DE5I
TO ACCOMMODATE THE ADDITIONAL LOADS INDICATED ON THE PLAN.
PROVIDE N FRSHOAMING IN DTL A OPENINGS $4 IN THE ROOF DECK SEE TYPICAL
CONDITIOIIN ROUND 16/.
5 IF A HEADER DOES NOT B IEB EAR AT A JOIST PANEL POINT. AN EXTRA L SMALL
BE ADDED IN THE FIELD.
9, O INDICATES LINTEL TYPE, SEE LNTEL SCHEDULE ON SHEET So.
10. 112=1 INDICATES CMU WALL.
II. PROVIDE FR.AMIING SIMILAR TO DETAIL :6/54 4T THE LOCATION OF THE SATELLITE
DISH AND THE (16) B' EMU'S IN ITS VICINITY
12. STEEL BEAMS CONNECTION AT THE CORNERS OF THE CMU PIERS SHALL BE
ACCOMPLISHED BY CLIP ANGLES L3x3z5f16x0'- 8' /z', WITH 'tea' FILLET IITL
TO EACH WEB.
13. FOR CONNECTION BETWEEN TWO W1Ox15 BEAMS, USE DETAILS SIMILAR TO 6/55.
14. FOR HE T ZTuf t I'IENT OF THE PLYWOOD TO THE FRAMING USE 'SxI i' BUGLE
HEAD SCREWS a 6. O.G. 'cDGES AND 12' O.G. FIELD.
15 FOR SPRINKLER ATTACHMENT TO ROOF JOISTS, SEE DETAILS 1 AND 2 ABOVE.
AYrtt"
FEB?''
ROOF JOISTS
y 3' MIN.
PIPE ':LANGER a ROD PER
sUBCONTRGCTOR OR A
JOIS ROOF
JOIST e STEEL ANC -LE AS
W
3
}
3
W F
BID /PERMIT
SET
rev. date
A
A
0
0
A
RECEIVED
crrr of n!rcwlla
SCALE:
PERMIT GEH, aI.
3/32::_1: -0"
ROOF
FRAMING
PLAN
S -2
1,14*esw
GAS PIPING Lip TO TFE ROCF
2. PSI WPM,
SEE SREET FOR CONINUATI.
GAS NERO. AND METER BY uTarn.
N.M. PRESSURE REGULATOR
TO BR. FRESEURE TO 10 RSA.
BEFORE GONG LEA To ...
-3/.. BALL vAINE AND
mor TO WALL RY.T.AAIT
IDEr AIL 181-6
-VT' CCTV... AIR L.
AVIR • A443..Fr
8.Ir. RANIEL
2 van TicsAT
To ERTERKR .LL !
iqhf /1
LCOnFROSSED AIR NE
ELASIABLE WASTE TRAP
PER DET.L BrFs
3° NEW UP
3/4 =FREES.> AIR LNE
INSTALLED BY P.
L W:WO tri0 11 8 MOO SAM,
zz le
=zzizzzzz.z7
NOM! ALL 01.1111ORK MI. ETC, UP TO
RoOF ato ADIST SPAcE IN T. ITRANT cITIR. AREA
FUST BE ONTO UNNIN ARCIATIECEAULLY
L.00,718DE NEAR ENNERIOR WALLS. IAERI,
LCCA DIME.SIONS UNA AFECRIEDERAL
DR...AS, AND COORIONA. W. TIE CENIEWS
.PRESENTATINE PRIOR TO AKT WORK
1 1 I
tr
tt
A° sToral noun To EISSIT.
STORM DRAIN ARON RD-I ABOvE
OvERRLOW Mat RD-2 aeovE ,
ovElactuTaalmancw.
AsSEVAIETIETIER
rETA.
-v. COLD ILIAMR
Fr FIRE PROTECIEN
Lle TO PIA.41.E NM
PLAN FCAR CCNTANATIcAK
AP MAW 61.1
FITIC.CTION RISER.
Llte 71. SYSTEM CCSITR...
! Izeme—
t i
-- — _. –
1 1 I
1 i 1
1
1 , 1 1
1 t 1 1
1 1 1
i
.1 .
t
r can max
9
2
IT Wat/.027 reZir
L fir Crif 6 I 1 O. M 2,92■0 re fr. r. 711rACM ree, Adf
=FILISSIZA. ,rofxamT F
OVERFLOW TER AT sown-
3° OvERFLoul FROM RD-2 A.130vE
STORM DRAIN FROM RD-I ABOvE
3. STORM DRAIN DallA TO EXISTING
IXISTING DOMESTIC utATERL.Ne _
1111
•1111
SQ.FT.CALCS
EST. G.O. DATE:
— 40,602 St
STAGING,
3,227 SF
--- 1,171 SF
TOTAL_
45,000 SF
1 ! C4.5-45
L
rEST FIXTU RING DATE:
rev. date
A
A
A
PERMIT SET
12/08/99
SCALE:
PLUMBING
FLOOR PLAN
M-2
KEYED NOTES:
ORUN INIANG AS 1.1.1 AS POSSIBLE IN JoBi SRAM
2 LA4 LUCK DIS.ANC-.. SUPPLED .7 INSTALLED Esy TIE
PUNE. CLNIRACToR
40Nar usm.
■Druker. coffrp..acr..R To n/I. c.cmen. FRot, sAns•
DouNSIACTIT TO EA cr 4, INDERGROLIND STORM ORAN PER
.TAIL 1.21-6. R. TO BRING STORM DRAIN on 3
FROM:11 EXTERSOR RNAL CONNECNON To SToRTI
0 -I, CRIPRE.ED AIR L. DOAN TO AIR OURS, AT Iv
APRS. DETAIL 6.1-..
0 -. 0.11ARESSED AIR LAE oo. TO NOSE .P_ RACK
0 -Ur conrossam AIR Lo. Dam TO AIR =LET AT N.
,I■7 s!...-T.A. WV1-t. COORDINATE DROP LCCATI01,1
0 BR. -3/4 COLD I.u.ave To Tura p.m epuT To Tms
ROM SNLIT TO SER. -UV CIE TO F-1 AND Er .1 To
314-2. wi.1-2 MUSTS ANAP. IN JOIST SpACE CAL MAN.",
SUPPORTED BY AIELE IRONS AS NE.SSARK .E n-3
FOR IEOMETRIC. .
1,14*esw
GAS PIPING Lip TO TFE ROCF
2. PSI WPM,
SEE SREET FOR CONINUATI.
GAS NERO. AND METER BY uTarn.
N.M. PRESSURE REGULATOR
TO BR. FRESEURE TO 10 RSA.
BEFORE GONG LEA To ...
-3/.. BALL vAINE AND
mor TO WALL RY.T.AAIT
IDEr AIL 181-6
-VT' CCTV... AIR L.
AVIR • A443..Fr
8.Ir. RANIEL
2 van TicsAT
To ERTERKR .LL !
iqhf /1
LCOnFROSSED AIR NE
ELASIABLE WASTE TRAP
PER DET.L BrFs
3° NEW UP
3/4 =FREES.> AIR LNE
INSTALLED BY P.
L W:WO tri0 11 8 MOO SAM,
zz le
=zzizzzzz.z7
NOM! ALL 01.1111ORK MI. ETC, UP TO
RoOF ato ADIST SPAcE IN T. ITRANT cITIR. AREA
FUST BE ONTO UNNIN ARCIATIECEAULLY
L.00,718DE NEAR ENNERIOR WALLS. IAERI,
LCCA DIME.SIONS UNA AFECRIEDERAL
DR...AS, AND COORIONA. W. TIE CENIEWS
.PRESENTATINE PRIOR TO AKT WORK
1 1 I
tr
tt
A° sToral noun To EISSIT.
STORM DRAIN ARON RD-I ABOvE
OvERRLOW Mat RD-2 aeovE ,
ovElactuTaalmancw.
AsSEVAIETIETIER
rETA.
-v. COLD ILIAMR
Fr FIRE PROTECIEN
Lle TO PIA.41.E NM
PLAN FCAR CCNTANATIcAK
AP MAW 61.1
FITIC.CTION RISER.
Llte 71. SYSTEM CCSITR...
! Izeme—
t i
-- — _. –
1 1 I
1 i 1
1
1 , 1 1
1 t 1 1
1 1 1
i
.1 .
t
r can max
9
2
IT Wat/.027 reZir
L fir Crif 6 I 1 O. M 2,92■0 re fr. r. 711rACM ree, Adf
=FILISSIZA. ,rofxamT F
OVERFLOW TER AT sown-
3° OvERFLoul FROM RD-2 A.130vE
STORM DRAIN FROM RD-I ABOvE
3. STORM DRAIN DallA TO EXISTING
IXISTING DOMESTIC utATERL.Ne _
1111
•1111
SQ.FT.CALCS
EST. G.O. DATE:
— 40,602 St
STAGING,
3,227 SF
--- 1,171 SF
TOTAL_
45,000 SF
1 ! C4.5-45
L
rEST FIXTU RING DATE:
rev. date
A
A
A
PERMIT SET
12/08/99
SCALE:
PLUMBING
FLOOR PLAN
M-2
Sanitary Waste and Vent Partial Plan
SCALE: 1/4 1' -0"
SQ. FT. CALLS
— 4n 602 SF
3,227 SF
1,171 SF
T 45,000 SF
CONCEPT:
C4.5 -45
• EST. FINDIRING DATE:
CONCEPT DATE:
09.01.99
EST. G.O. DATE:
16
6 Notes
(SCALE: 1
ONE
1 I DETAIL 11
(SCALE: 1 " =1 -0"
DETAIL 16
SCALE: 1"=P-0"
DETAIL 21
k NOTES:
QQ FLUSH VALVE SHALL BE LOCATrBD OV TI-05 SIDE
CP THE FIXNRE TO MEET ADA RE.DUIREr'ENIT5.
® PROVIDE TRAP SEAL PRIMER FOR EACH FLOOR
DRAM. SEE DETAIL 5.41 -6.
® PLUMBING CONTRACTOR TO BRING 4' SANITARY
SEWER TO 5' -0" FROM _BUILDING EXTERIOR
CONNECTION TO SANITARY MAN BY 011-ERG.
® 2" COLD WATER AND I" HOT WATER DQW FROM
JOIST SPACE TO RUN LOW M FLUME . WALL.
=INURE DESIGNATION
TAG
F -I
F -lA
F -2
F -2A
F -3
F -4
F -5
F -6
FD -1
FD -2
FD -3
DESCRIPTION
WATER CLOSETFi_OOR NKYRRED)
WATER CLOSET (HANDICAP,
LAVATORY
LAVATORY -WALL 4#RJCs
URINAL
MOP SINK
DRINK.. FOUNTAIN'
SINK
FLOOR DRAIN
FLOOR DRAM WRH 5WI ENT BUCKET
TRENCH DRAIN
SEE SPECIFICATIONS FOR FURTHER INFORMATION
12
22
NR
Sanitary Waste and Vent Isometric Diagram
LVX
FAA
H
FDA 6.1
RHO-
WIG 6EE NFLFICATILN SEGTRFE
6160, PAW 30S,FGRI E
POril -w CLfmlE
r
6�
3/4
SHEET n -2 " -
FOR COMMA
24 'Domestic Hot and Cold isometric Diagram
/ / / /// / ///
Tree V' S.. ABSCfEER/Bff
SPGFIGTIRE WRY.ODEL)
T' CAL
WATER HEATER
5JSPENDED ABOVE JANITOS'S
SINK PER DETAIL 2/n -6
2" COLD 1114TERI
F -2
0 F V \
J
.2
3/4"
HOSE 6188 At
SiEfEO wSTALL
WA. FOR HCSE
BIBBB AT 2YF HATCH
r'wE OU /
F6 I L
LICEL SEE SF£CRH:ATIR! SECTION
NW, PAW 3.11,raRfDRWE
Ii0.1141 SCHEDULE
A" CAL gaTi AIAFR rffFR
SEE MEET ,1-2 B712 CCNTAllATICH
rn gq'l7L '.
rev. date
A
A
A
A
A
RECEIVED
m OF TUKWILA
RAPT CEP,.
SCALE:
AS NOTED
ENLARGED
PLUMBING
PLANS AND
DETAILS
M -3
PERMIT SET
12/08/99
16LE TTPE P IPANSER
0) TIES. On
66E1E6 INSTALLED LLRL
8EE SECROADETEL 6 ;
SETA/LAMM NO7E6
0 - - - - - - - - - -
COP
TO ESL..
1P AFF.
E LOW
468 UP WWII. ROOF
TO SEE DETAIL
CONTROLLED
EFT LIG. EEC,
EWE
4' 0 O71.711:T=71= UC
i WOO CR1
- - :
=see
Dew_
I
: 1!
L
ES. I
2
I , —
—i
,
Rru-s0 I mr1.6s0 - ESEL2
1.6-SQ)
I-R- , - 1-=: . :::
. ,--- : 56•80 LEI
- 1 - '''''''''' -- - - - - - - -- '' ___.
ES. I
1 ' I
T- - - - - - - - ;
T ; r I some cFrr
I
— • — - — - —
0
L I ■
‘9,...®
RIL-120 ZSTLTPM
1-1.0 TONS
600 CRI 600 OW 0 000
T.ff r r -
,
11
_ -;---
—,„-5FRER.VAL.P1.44.17gesAREA
SEE BERME- 1.10TE 9
tre
011
1.0
oce.r.c., To ma nee.. oiler
660 INTOPI.R.FIEFACE AEO.
12-S2 TONS
N
4 - RE TYPE P GRILLE ers
rot
BALLICSB
SWAB ROORL-AND BACK TO 126.1-.
MILE - FELURI REF TO
EF-LPE,LE-E-6B- ;
_ _ 028FOLLEI7BT LENT LEEN
j O-L-R7 I
, 1 C
000 C101
CEENESALTAZTRIL
21'2';'"' FEE PROECITON EL.
WIRING, ETC- UP TO ROO. 101. SPACE MET BE ENCLOSED
_ J.011-10 ARC011EGTURALLY
PEERS
ARCHITECTURAL DRAWINGS, AND 00012010ATE
REFRESENTATRE PRIOR TO MT WORK
FANS 01.1.0.1 eve. OFF INIEN FEE ALARM IS
ACIIVATM: ,
A ELIEMLIal.
A FILULT ALL EXPOSED DIETWORC RECUR-Oa ENTIRE
BELOW; AS HER POSSIBLE
ELOEPTIO8 DUCIWORK AISC0F CFR. AREA ELALL
BE COWPAI FD. SEE SLEET
Fi MOOR ALL PLS., DIFFUSER llifT5 AS RIGN
POSSIBLE THROLEN OUT TIE ENTRE MLLE.
COORDEATE 8810 GET APPROVAL FRO, LENEFE
SEPRESENTATIVE
etrurr AU_ UNIT LEATEIFS AS HI. AS POSSIBLE
ELEKELIAMLIEE.
BALANCE FOR MAXIM', THROW CP AIR REVERED BY ORIER
SISTALLIE, AND 5.0-010E SIT FRAC CONTRACIOR.
KEYED NOTS,
reurr peFeereo acrlown.war.reur eutu,r.
-AS REI AS POSSIBLE LRESS MOS. IVIED.
RLCROP imam SIFF, [FERBER RD REEL NEER
17 , Er rA LEITAFSZ
® NSTALlEP 0150. eflOIF £17 CELLE TO
FRE ROI CF FERE AIR
Faczroe an ma D.. &PRY eszesrm..41
.0 REM REM. FER DETAIL 2,141.
® WOW, r LaThmo &FELT o stem>
OZENNATION WERE DEVER TO SE
T.FOrtl ANT RATED tua.u_ eareraL
T ltr- , &VET USI ARIRITECt TELT UAL E
R111-be SEN1.1.00 TAGFORFRATEJ 620004
NOW AT T-0 AFF, LNLEES meass Nom.
VERMOSTAT 00 TAG KR RELATED BEEFIER
MET AT T-0 AFF. MESS ONERNE NOTED.
0/ TTF£ GRILLES. ET EN DROP.
CEIL S. RF_S , TIROOX, ERILLE
BEREEN. SEE DETAIL. EMI, TYPICAL FOR
ALL CV 81.4.01 =NEE 1.0 OR, TRANSFER
TIERFIOSTAT IN ELECTRIC ROA,
REVERSE AWING TO START EF-1
• ROC11 TEMP. E<CEF-DS F
1'0147. SEE DETAIL 88-1-1
laxi4 OPENME RM.
OF DUCT. PROvIDE
, I ,WIRE19E
rrtger02
Eg
SQ. FT. CALLS
40,602 SF
STAGING:
3,227 SF
1,171 SF
45,000 SF
CONCEPT:
C4.5-45
CONCEPT DATE:
09.01.99
EST. FIXTURING DATE:
EST. G.O. DATE:
SCALE:
PERMIT SET
12/08/99
rev. date
A
A
A
cr TY La
PERMIT GEM FE
3/32" = 1'-0"
HI/AC FLOOR
PLAN
Alf A
RTLI-12
3 TONS
1,00 CFM
I2"0 SUPPLY FRCM
12 SUPPLY PROM RTU-13
N 6 r i
I
I
i I
I I
I 1
I
EPPLY FROM R7U-2
I2 NIPPILY FROM RTU-I4 EET
12"ONIPPLT PRO R11.1-14
A .Tal
1.4P/
NOE_
ALL DUCTWORK, PRE PROTECTION PIPNG, ELECTRICAL
URNS, Ecr. IP TO ROOF JOIST SPACE MST EE
ENCLOSED UM ARDNTECTURALLY LOCAllED
EXTERIOR WALE VERFT EXACT LOCATION DII1ENSIONS
(VW ARCHITECTURAL DRAM., COORDINATE WITH
0111ERS RE.RESPATATIVE PRIOR TO AM' WORK.
ES 0
I I
F . c Store Front Elevation
SCALE 1/4' = "
102x10 MEM. WALL SP
UP TO 0 DUCT TO R11.1-13
VEPJFT EXACT DIMENSIONS
WITH ARCHITECTURAL
IR 5A
1\1
OaRECTIONS TO Ir0 .TURN
DUCT WIEN FL911.11 OALL TO
ISE RED FABRICATED BY ISCIL CONT.
WALL CONSTRUCDCN STUD
LOCATIONS TO FE VERSED 14 FIELD.
COORDINATE WITH GEER. FOR THE AFBA
SEE SECTION 3r,
41 GRILLES_ CU OR21E DRCA.PED
OFFICE, CD emu war.cia. ABO,E CE.CE.
4 DUCT BETLIEEN DETAIL 10kI-1 r
FOR ALL (4 ARC. TI41.
I
ORTU
I
F
C _ _
490
90:14 P RA GRIIJ-E
WNW AT 6" AFT. U.
Et-ADESIUREVDOILT,
(2P-4
(DH.V.A.C. Partial Plan at Front Offices/Vestibule
SCALE: 1/4" = 1
Vt.& NIRERCED
LSE LP SUFFCRTS
ERR 1714DOOFILUONG
C 14 SEAM OR SPAR. E
07.1-4Ard
//
IlltIP I - - 0
-
INFONIVAII4111/2115/111511/151PAPII
■OrAttrA
.4,
AUWAWAMMIWO
0
SUPPLY FROM RTU-6
RETURN TO RTU-I5
EV NIPPILY DUCT TO SPLIT
INTO (2)1410 DUCTS TO VESTIELE
(ADDITIONAL NPPLT DUCT AND
DIFREER N SECURITY ROOM NOT SNCALN,
ABOVE OFFICES /- FLARE FROM 30xI2 TO
4 AT PLENUM WALL
TOP OF
eoncrt OF
N SEOJPJTT ROOK
VERFT ELEVATION WITH
ARDATECTURAL DRAWINGS
I0.10 PLENUM WALL SPACE
UP TO ENE CONIECTIGN TO
3.2 PLENUM FOR RETURN TO RTU-10
0 RN-I5
(ZnMechanical Section at Vestibule
SHEET METAL TO PENETRATE THROUGH SHEETROCK
PLENLM WALL AND BE SEALED TIGHTLY ARO.)
ENTIRE PETETRATION. WALL COSTRICTION alD STUD
LOCATIONS TO BE VERIFED N
COORDNATE LIATI4 GENERAL FOR THE AIWA
14 RIPPLY TO VESTIBULE
(IDENTICAL BEYOND, NOT SHOIN)
ALL PENETRATIONS 'THROUGH
PLEAPI WALL MUST BE SEALED
TISHTLT AROUIV ENTIRE PERIMETER
ANT WIRNS ELECTRICAL TIERMOSTAT, ECT-
INSIDE PLENUM ULALL MST BE FLEW RATED
ALL PENETRATIONS OF PLENUM MUST BE
SEALED COMPLETELY.
SHI.T METAL FLAW. TO PENETRATE
SEETROCK PLENUM WALL AND BE SEALED.
RETURN GRILLE TO SPAN OPENR.5 AND BE
SECURE, ATTACHED TO STUDS.
(3 Wall Detail at Security/Vestibule
SCALE: NTS
4■
70,
_MIMI
‚In'
III
NH
•EM
MIA
SQ. Ff. CALCS
STAGING:
3,227 SF
1,171 SF
' SF
CONCEPT
C4.5-45
CONCEPT DATE.
09.01.99
EST. FIXTURING DATE:
EST. G.O. DATE,
ONE, O
O602 SF
PERMIT SET
12/08/99
rev. the
A
A
A
cr,A71%.
PERM C
SCALE:
AS NOTED
HVAC
ELEVATION
M-5
1
AIR
\ /
-' IC COYER [ FRAME BY PLUMBING
OR INSULATE COVER TO
BASIN FRO, FREEZING
LUBRICATOR
-
AIR DRYER
— — . 24'
PRESSURE (�IS:LATRG r(�
WITH DISCHARGE /--,
PRES51iR'c GUUGE
' •
03I
u 21-2 j
fl i
-//'--1111301010111:1
,
'..
SHUTOFF (BALL) VALVE
AL) VALVE \
(TYPICAL L
TANK PRES°,1JTE f -'IK� � \
/�1
-^ I BYPASS ❑ ❑❑❑011❑
INSIDE HEAT 1ACE 8T ML. _
I-
2" NO HUB
.�
1 I I— CONNECT
;:R
I � COLD DATER w TTPE 4 - [izA.c oPSars MODEL MB. Ifl$PG
E .Y� CONTRACTOR DAMS TO
r
JTIL PIPE IS
205T LB.
{ FLEX ! SCT�ti@ -P TO Il E TRENCH
O� ..L FD -i EXPANSION TAM CF GRA. FRAME
.....
-
`.
�
CLNDUtt SEE '
/////- /II[� CGT6.ECtIGf1 E
- A TMRMd6TROL 2 C-GY'LCN, /
_
PRE RELIEF WATER OUT C % HOVEL 5T-5
I
RE AND
\
I� u�
I
1
\ �
v
5 �
° ,
,N
�
J
EL. VALVE
.
V
a
LNICS4 OTPKJU
STRAP WATER HEATE2
TO WALL SUDS
71W LOCAilONS
'.
PR ,. STUCURALLY CALMAT
\
/
I�
DOIW TO
;;:
... RETE PAD SIK
.. c4
4S, THICK
:�
RE DO1N TO
STRJT 3FtnRF?O W4T15nDS I
1 i
" TkC
MCI. BOLT (dIILK -SET
INTO CONCRETE
2K. OR FLOOR ABOVE MOP MK I
CONCRETE B. =Y
'ERCURY
M I
J
/
J�
MMTE�.N. DRAW.
2' DEEP Bi71P1A5P.0 I 171R1L F
COATED DRIP PAN
BT C+9•ERAL CONTRACTOR
FLOAT OR
NS1D D - (OR WIDTH, O:
✓L OSI FILTER
i0 BE . LE55 THAN 48" TER
SCREEN N ' Fl TAKE
imiliiiiiiimmumwavinegmm
1 !Air Receiver Piping
2 Electric Water Heater Piping Detail 3 !Trench Drain (FD-3)
ISCALE N.T.S. { ISCAIE .i"'73
I SCALE: N.T.S.
WION, TYPICAL
c�F PLAT.
t€
E::EcaL O
�—
.TEICR FACE OF WALL, TYP.
DCB ptF,5g
ALVE
fa
DRAM VALVE
GATE VAL
r �� `3RMFifnON 3idf.Nf
DOUNITTO 6'ar 8 ". Td71IU7
I ' "�
FHY/
M. EEY I
I } AFF- I _
TOfdT S�2P'✓F£
CLEANWT
,o,
MMIEMNIIMINIMIIIMEMMEIMMIIEMIRMOMMMIIIN
1•'
j IiJJ
b " MM
' 3" MM
2 " CAPPED VALVE FOR
BALL VALVE [UNOCAL :
f _
}OPEN @DED PR'E _:
-
SQ. FT. CALCS
PIPE SIZE SAME c PLANS t
.(
FUTIB� LAUN IRRIGATION
ATI N
!`\
.. C I I 1 °
DRAIN CONNECTION
SIZE ON MIT CONTINUATION
PIPE
...,
SYSTEM (COMM W
`
.UATE25ERY1� MO THREADS). E _
_
- VI OW 501FR
r
p E - r
TAI I, S
0,602
AGING:
3,227 SF
STSTML RE. TO PLANS FOR
LOCA. .
L: 1,171 SF
"45,000 SF
CONCEPT:
1- C T
Water Me ter Piping Detail Ai Drop r o ut
5 i P g 6 P WnSpO
g Condensate Drain
ISCALE: N,T.S.
DATE:
CONCEPT DATE:
09.01.99
SCALE: N.T.S. (SCALE N.T.S. ISCATE N_TS_
4 "MN8101 -E COVER-
OCR
=
WALL (SEE RAM
PL
VEIN UP M �
NECESSARY. UP FINE TOWALL S EXTERIOR BLO(K WALL
M IF NE4�ST WALL
�I
T
I
BA LL VALVE
ALL CL=#�lTS N RIMED FLOOR
COVERADASTAB. FRAT'E AND
KJKa,
_s,
-
{'
PIPES , (2) PER
EST. FLXTURNG DATE:
EST. G.O. DATE:
i 3"
+
O
p
Q
,.
3G a
� H .a
z
W
d
I
PERMIT SET
12/08/99
rev. date
PIPE OR CONDUIT, TM ip
.043 PVC
UAW.. (3.4 SIDES - I ( f,
} ° 0 x2 "LONG MN
/ PLATED LAG SCREWS
BLOCKING SHEET 2°
BEYOND ELOCK.
BETO
INSULATION
T °
rrp. SEE
)
;'
;;:
i
CUTLET A
'
j j.ij:: jiis
IMrar;1�
m
AND
E.. NECK AS AS REQUIRED
:
N✓oT�'.
L PROVIDE GAS PIPING
2. PROVIDE GAS PPM
1" EVERY 5'
I }° EVERY S ' 1
`
'
SUPPORT AT L FITTINGS.
SUPPORTS ACCORD. TO PIPE SIZE°
}" EVERT b' 1" EVERY l'
i" EVERY s' T ' EVERY 10
TO MIMI fi
ION
6" DIRT LEG
��
INLET DEC.. AT
3" MOD WATERLINE
4 IN.
IUCLEL
L CONTRACTOR IS F.SPONSIBLE FOR VERIFICATION
OF AND CP.'IPLItW(� WTN GOVERNGOVERNING , YE CODES.
2. WASTE TRAP TO HAVE MINU121 VOLUME = 35 o. FEET
EXIES4MI BODY WITH SERRATIONS
P[J' r YDIC- CUT -O ADJUS71"®NTS.
\
l r t
Ck1GT3E fid ORCVST Csq•I SOIL PIPE
9 j Flammable Waste Trap
io I Gas Piping Schematic H I Cleanou (C -O ")
12 I Gas Piping Support
N.T.S. CALE: N.S.
SCALE: N.T.S. r jSCAL= 'NUS
'SCALE: N.T.S.
TOP + ROOF CURB TO
BE L CONFIRM ROOF
PITCH =� .. CURB FABRICATION.
SHIM �w -
20 GAUGE SHEET
METAL HOOD
\ \\
FASTEN 3. OC
SEAL WASHER
SCREW TO CU ._
.
/
SEE DRAWINGS
NUMBER CF 5.
Slg'�OCATION
/
(SLOPE TOP WEATHER HO
, HEOD
®� EXTENSION
C.I. TRAFFIC
RAIS ED HEAD TOP W�SCf€WS
CLEAN OUT PUG
FINISH GRADE
MO/CRETE,
TYPE 2
JDSAM
N
-FOR
VALVE
CO. H. E ES T ROSE AS II
PENETRATION stop. BY RECOMMENDED ROSE neTTF TYPE 1
ROOF MANE MAP fit. PP+tER -ACNE
CLAMP.* RNG,
A
RECENEo
crtY OF TUKWI1q
PERM CENTfF
SCALE:
AS NOTED
MECHANICAL
DETAILS
M_ 6
-
PIP SLEEVE i0 RE1'�A OFEJ
AT TOP AROUND GAS PPE
FOR VENTILATION ^
ROLFM AE AMAO 6FAL0"AC PFJ'S2
Pi �ei"�A@ PEE I MADMAN. Tx ITS -
P.ODT, BY ROOF MAYF
L(AD WATER LL.
�_
PVC 111B.RNE NCETS
ROLFlINCz TOF
I
t��w
......... , - ....:
• . "'
Y W °' i r
" .- TRAP PRMERFlTTMG
u MOAN VALVE VER - 71 - N
.
( v �' ■
i s � "'i
I
ANCHOR FLANGE
/
C J. ACCESS BOX-
EXTENSION PIPE
AS R'cOUIRED
+
THR15i BLOCKING
MANIF STANDARD
I 2 AR
METAL ROOF DECK '.
WELD JOINT
.ALDER PIPE SLEEVE
TO BASE PLATE
=
.AN? NBLAT
MONDE SLEVE AND
RSULAGON A%71ND GAS PIPE w.
PLETM (WERE
3P72 GRAN
I FLOOR:
I
/ CAULK AROIII7D
PIPING
C
��410116
DROPPED CEILING
AM/CABLE/
APPLICABLE)
° L
1 T�SEAL L. kw
,6-
ROGf ..
5" BAIT
INSULATION
-- •
���
,-
VII IIIs
AFPLV'dFV F) ��
'�
'.
_ CT
o ' _ " TO TRAP. CONNECT
RUSH RE OR.
. ���� I � �� /�
-
IS GAUGE GALVANIZED
SHEET METAL OFIINMG Ot TRIM 1JIL'
TO COVER IY I
A • E
c og 5, 10
0 ..w . I A
PROVIDE TRAP PR..
CH ALL FLOORDRAIS
ADO TRW. DRAINS
El . - A COD WATERLINE
�'.,. GAS LPN' TO INTERIOR
SEAL PIPE SLEEVE
TIGHT TO GAS PIPE •
JUST BELOW CEILING
=
13 Two -Way Cleanout (D.C.0.)
14 Gas Piping Through Roof
1 Re -Seal Detail
16 Refrigeration Pipe Through Roof
RYE EMWAST
OVAL
SEAL AL R E JOINTS
AMEN TEtF! SRIGCbE
w�T'EWS "CN AR M.ET
S' OYA-
PROVEE STORM COJL.R
AND RO F r1.A.AN
Er OVAL
STRAPS, 4 . 43 P4ifti
CONC3fiRIC ADAPFER
.AL ALL RUE JOINTS
mic4+TEPP. sums
ATE - MANUFACTURED VERTICAL
VENr/CMEUSTICN AIR PIPE (BACK
TO MIT HE4TER)T3T MANFAC URBR
e1H
WIT HEATER SUSPENDED
WIN ROD RANGE.
KITES
L M= err11. - 7 !EATER AS Ida,
AS POSSIBLE.
2 FOLLOW MAJFALNfx£.
INSTALLATION INSTRUCTIONS
'1111
1111
rim
-
SQ. FT. CALCS
40,602 SF
3,227 SF
�1171SF
45 000 SF
CONCEPT'
C4.5 -45
CONCEPT DATE
09.01.99
EST. EIXTf RING DATE:
EST. G.O. DACE
INSULATE CURB CAVITY
UATN FIBERGLASS BATT
M5ULATIC N
SEE DETAIL 5M-T
POUER URNS UP THROUGH BASE OF LW
TO BEAKER MOMED ON SIDE CF UNIT
PROVIDE SMOKE DETECTORS PER LOCAL
CODES. INSTALLED BY 14VAC CONTRACTOR AND
FURNISHED BY EL. (TYR SUPPLY < REM.
SUPPLY AIR
NOT€; ROOFTOP W IT AND CURS FURNISHED FADER
NATIONAL ACCOUNTS, 5EE FURNISH/MULL SCHEDULE ON
ARO,'ITECTURAL SHEETS
URN AND CURB INSTALLED BY 14VAC CONTRACTOR
1 !Typical Rooftop Unit (Ducted)
(SCALE: N.T.S.
3 1 Burgular Bars
!SCALE: NY.S:
5 '[Roof Penetration Protection
I SCALE: N.T.S.
RETUNING ANGLES SECURED
TO SLEEVE ONLY UM, 1"
BOLTS OR WLDED BEADS
5 -5LIP JOINT COLLAR
TIP. ALL FOUR SIDES
NOTES_
7 Smoke & Fire Damper
L
4x4x1° ANGL.E IRON
FIELDED TO ANNE
1.1 FRAME AND
J015T5. COORDINATE
SITES UM PLANS
1' 0 CASE HARDH&D STEEL
BAS WELD., AT 6° 0.C. EACH
WAY TO 4.44 FRAM, SKIP
WELDED
ROO TOP WITS RA•PLED WIN E1KiAR BAR
ASSEMBLES, U NICA A ac DROPPED NTO
OAS (BY HVAC CONTRACTOR), PLENUM
OP£NC:S N a`eOEED INTO PDS TRH.
STEEL JOISTS, SEE STRICT.
L INSTALLATION INSTRUCTIONS ARE AS PER MANUFACTURERS Ul
ASSEMBLY. VERIFY EACH MANIFACR RIGS INSTALLATION REQUIREMENTS.
,r FIRE DAMPER
RETANPE ANGLES ALL (AL FOUR 51DE5J
SHALL BE AC-CORDING TO DUCT SIZE:
-44. U' TO 45"
- 2.x16 GAI E, GREATER THAN 45"
ACCESS DOOR •
BOTTOM OR SIDE
a.. SHALL BE
MINIMUM E GA UP TO 36"
AND 14 GA OVER 36"
2. DAMPER SHALL BE VON AND BE POUERED OPEN. DAMPER MOTOR TO
BE CONNECTED TO FIRE ALARM SYSTEM DAMPER SHALL CLOSE UPON ANY
SMOKE OR FIRE ALARM M BUILDING
OUTDOOR
AIR INTAKE
RTU CONDDISITE ORAN
CRJD=J.SATE TRAP PER DETAIL BM-6
B RELAR BAS PER 3M -1, 5M -1
(TYPICAL SPELT ANA RDUFW
THERMOSTAT WRING
BALANCE. DAMPER OPPOSED
BLADE DAMPER TYPE
TOP CF GRILLE
3'-0" APE
CONFER FAN. /Bl" HVAC CONTR)
INSULATED PETAL CISB Br AARBNT
1141FACTARt 5. CURS DETAW ON
ARCHITECTURAL S.T.
P.'SIATE CARD CAVITY
WNH FBERGLASS BATT
MSUATDN
E. DETAIL 5M -1
POTTIER WIRING UP THROUSH BASE CF WIT
TO BREAKER MONTED ON SIDE CP UNIT
L ROOFTOP INT AND CURB RM.., UNDER
NATIONAL ACCOh75, SCE R9395L115TA' L WED.
ON ARCHRECIUR% SHEETS.
2. WIT AND QM META ED BY HVAC CONTRACTOR
FOR DETAILED PFORMATION REGARAPG SPRY AND
RETURN P. M%SE 6M -1_
Typical Rooftop Unit (Supply/Return Plenum)
j SCALE: N.T_S.
TOP CF WALL TOP OF COYF ESSCR ROOM TO
• 8'-0" APP. —. N...., / REMAIN OP'ELNO MUG.
:EL
4 1Section at Air Compressor Closet
SCALE: N.TS
ROOF DECK
ROOF MEMBRANE RAMS IE
(Br ROCFEW
ROOF NSLLATION (BT
NOTES-
T
BAR JOIST
L THIS DETAIL APPLES TO ANr MECHANICAL OPENINGS LARS. THAN e"
IN ANY DRECTK N, OR 100 SQUARE NOE5 OR LARGER
2. ALL CURBS METALLED BY HVAC COMB EOJIRMBNT PENNED UNDER
NATIONAL ACCOMS WILL COPE WRH ROOF 01.5. ALL OTHER CUBS TO
BE R1RNI5HED BY HVAC CCTNTR
3.
14VAC CONTR SHALL LEVEL ALL OUR05.
4. ALL BAR .A.R BARS INSTALLED BY HVAC CONTR ROOFTOP WR
BURGLAR BARS RRNISIED WTH WIT, ALL OTHERS FURISED BY HVAC
CGNiR
R
BIRD SCREEN
MOTOR/ED OPPOSED-BLADE
DAMPER
I° EXT.JOR INSULATION
2° DEEP DRIP PAN SOLDERED
WATER TIGHT. COAT BOTTOM
WIN ONE LAYER OF BITUMASTIC
Exhaust Fan Roof Ventilator
TOP OF GRItlE
• I-6" APP
DUGNORC
....II. OF OAS AREA
BY HVAC CONTRACTOR
LEVEL'. CF CURS BY
HVAC CONTRACTOR
SEAL AND FASTEN DUCT
TO FRAME WITH SCREWS
51..2 BARS
DUCPLOTEK (SEE RANE)
0
S" PUNAIM
- + AAR PVAKE
RN COFD35ATE DRAM
CONDBEATE TRAP PER DETAIL EPI-6 !I
ROOF DEO( 7{�
P OVIDE 547K- DETECTORS PER
LOCAL CODES. NSTA2 ®Br WIC
CONTRACTOR AID RRNI NEE BY EC.
ITT, RIPPLY N RETURN/
PROVIDE ACCESS PANB-5 TO SEE I
DETECTORS PER LOCAL CODES_
(TYPICAL SPELT AND RETURN?
6 Rooftop Unit Supply and Return Plenum Detail/Specifications
SCALE N.TS
CURB t FLASHPG BY HVAC
CONK PER DETAL 5M -7
ROCF DECK,
SI GL AR BARS AS RECUIFED,
FFR DETALI3M -1
■
INSULATE E OERNAL1T
MNMM CF
FROM ROOF MEWS
TU I G VANES
q Unit Heat
rn9q
I IYOF '
APPRC,''ED
FEB 1,
PERMIT SET
12/08/99
rev
A
A
0
A
A
A
date
OTaV OF
1
PERM, .r, EE
SCALE:
AS NOTED
Q
m l
MECHANICAL
DETAILS
Ru� C1� `
',. DRS B6X
TOP CF
aEVATICII '
EKRTCt1ioFJO30 ISTS.
ELEvATICIN
-imag ARM=
WAFFLED
``
��
3Y
ill
HVAC CONTRACTOR)
rfi�
EGMlAL TO
DEPTH
JOISTS
/rys
Hp
12
NOTE:
GC TO
NOTE: ROOFTOP UNIT ORIENTATION
WITH RESPECT TO JOIST TO BE
VERIFIED IN FIELD, AND
COORDINATED WITH BEST BUY
REPRESENTATIVE.
`��o /Sr
<y
r0 tr
AIR FLOW
RETURN DUCT TO BE LOCATED UP
JOIST SPACE. ROTATE DEFENDING\
ON DIRECTION OF JOISTS. TS. FRONDE
TRANSITIONS AS REGIJIRED
-
BOTTOM OF RETURN DUCT SHALL
NOT HANG BELOW JOISTS
ALL ITEMS INSTALLED 8Y NVAC CONTRACTOR
LABEL ALL DIFFUSERS WITH NE CORRESPONDING ROOFTOP UNIT IT SERVE 'S.
L&&V> ID STET! C0115T1710N THE NUMBER SHALL BE A MIN OF 6 AND BE PLACED ON THE SIDE OPPOSITE
2• - t5 LEt massy ALAi1ON LF•zA" THE STORE FRONT (FACING REAR OF STORE)...
3_ Mr ORE YEW DRAKE GRILLE ELEC /CONTROL. WIRING BY OTHERS
( OP's
4.y5UICAQ DROP SAME ST L AS CURB
0 RIPPLY AIR DUCT (SIFPLE7 5 HVAC CONTRACTOR)
A
-- -
��''.
RI4
0
L GALYAIIO 51 CCIETP - DON
r -,t5 La Del5PiY EXTERNAL rasULATON
3FiROY40E Iii ANSIITCF6 AS PE'"E.:ARY TO
COtFLE GON iicN TO CL R3. TRANS SHOP DReISYS FORT AiION DROP 55
0 aJF1 x DROP BOX (a�F! BY Tim CD)
t $/Q
F
I
I
E UB�$ATE D SJFFLT DROP BOX HAS SCYiE
DErn EGZON t sCi5i tia IIIN.PARAJ EL 4DE
DAPF
2.6'FOR?T - �T Larly rt a OF NE SFITLY AIR
G- .L. AT OS-�5 Q 5T,4?j_ATION
REQUIRED ON:
I
- _
✓ TSDBU85DB AND T008240DB ONLY
NOTE:
BLANK OFF CAN SE INSTALLED
EITHER SIDE.
Rill 0.1125 (SUPPLIED 3Y 'MANE Ca) 1 t G C E
ON
9•OE = T eOR(ESE L. BYSJ
9.5C DETECTOR> i.Q D_
COORDINATE MN JOISTS fl -.
RR' TED BY E> CORER
INSTALLED LLED BY IWAC COMM
8
I
DIMENSIONAL DATA
T' RAII
' I
TONS , ND I THROW CFM
:DEL
A
B
C
D
E
E -a
if
0
H
J
K
L
46 8"
83 j"
22 8'
39 8'
H 4"
2 i"
32 4'
13 g'
24
10
20
13
TCD/TCD.31
3 aSsDO8DD5 35' 1200
TCz'JTCDJ04S
TSD560.05 35' 1600
46 e"
83 ;"
22 e'
39 i°
II 4"
2 i"
32 a`
13 8'
24
10
20
13
I TCD!i
5 <SDS85DS 35' 1950
49 g"
81 k
22 2'
42 i"
13"
3 4'
35 4 ",
5 k
24
10
20
13
GP 0 i4
r aes, 03T
6 � 20
T 1SD590DB , 40 ' ! 3mmm
5n
49 g
81 g "
22 "
42 g'
13"
3 4"
1
35 a
5 g '
30
10
24
15
TCDrfC1T103C
3, TSDESI20D3 TR ! 3400
59a"
89 4"
19 in
55 16'
19 in
2"
41 an
24 in
36"
12"
22"
22"
TCD/TCEJF2TC
t0 T508123DB ?•S 4000
62 Z"
106 4"
22 1'
62
18 4"
4 4"
54 4"
26 Z '
36"
12"
22"
26"
TCD/YCDRIC
TSDBTBove 60' 5 000
62 i"
106 i"
22 #"
62 i"
18 4"
4 4"
54 i"
2 6
46"
12"
36"
26"
TGr3/YCCRS1C
6 T5D5I83105 b0,' 6000
81"
111 a"
23 4"
11"
22 4"
2 "
69 "
24 I 6"
46"
12"
36"
26"
TO?/YCD
211 -241C
20 TSD8240D3 i TIV SIDOID
110,000
81"
In ��
4��
23
ll"
„
22 4
2"
I „
69 2
5
28 r
"
46"
18"
36"
26"
RYE EMWAST
OVAL
SEAL AL R E JOINTS
AMEN TEtF! SRIGCbE
w�T'EWS "CN AR M.ET
S' OYA-
PROVEE STORM COJL.R
AND RO F r1.A.AN
Er OVAL
STRAPS, 4 . 43 P4ifti
CONC3fiRIC ADAPFER
.AL ALL RUE JOINTS
mic4+TEPP. sums
ATE - MANUFACTURED VERTICAL
VENr/CMEUSTICN AIR PIPE (BACK
TO MIT HE4TER)T3T MANFAC URBR
e1H
WIT HEATER SUSPENDED
WIN ROD RANGE.
KITES
L M= err11. - 7 !EATER AS Ida,
AS POSSIBLE.
2 FOLLOW MAJFALNfx£.
INSTALLATION INSTRUCTIONS
'1111
1111
rim
-
SQ. FT. CALCS
40,602 SF
3,227 SF
�1171SF
45 000 SF
CONCEPT'
C4.5 -45
CONCEPT DATE
09.01.99
EST. EIXTf RING DATE:
EST. G.O. DACE
INSULATE CURB CAVITY
UATN FIBERGLASS BATT
M5ULATIC N
SEE DETAIL 5M-T
POUER URNS UP THROUGH BASE OF LW
TO BEAKER MOMED ON SIDE CF UNIT
PROVIDE SMOKE DETECTORS PER LOCAL
CODES. INSTALLED BY 14VAC CONTRACTOR AND
FURNISHED BY EL. (TYR SUPPLY < REM.
SUPPLY AIR
NOT€; ROOFTOP W IT AND CURS FURNISHED FADER
NATIONAL ACCOUNTS, 5EE FURNISH/MULL SCHEDULE ON
ARO,'ITECTURAL SHEETS
URN AND CURB INSTALLED BY 14VAC CONTRACTOR
1 !Typical Rooftop Unit (Ducted)
(SCALE: N.T.S.
3 1 Burgular Bars
!SCALE: NY.S:
5 '[Roof Penetration Protection
I SCALE: N.T.S.
RETUNING ANGLES SECURED
TO SLEEVE ONLY UM, 1"
BOLTS OR WLDED BEADS
5 -5LIP JOINT COLLAR
TIP. ALL FOUR SIDES
NOTES_
7 Smoke & Fire Damper
L
4x4x1° ANGL.E IRON
FIELDED TO ANNE
1.1 FRAME AND
J015T5. COORDINATE
SITES UM PLANS
1' 0 CASE HARDH&D STEEL
BAS WELD., AT 6° 0.C. EACH
WAY TO 4.44 FRAM, SKIP
WELDED
ROO TOP WITS RA•PLED WIN E1KiAR BAR
ASSEMBLES, U NICA A ac DROPPED NTO
OAS (BY HVAC CONTRACTOR), PLENUM
OP£NC:S N a`eOEED INTO PDS TRH.
STEEL JOISTS, SEE STRICT.
L INSTALLATION INSTRUCTIONS ARE AS PER MANUFACTURERS Ul
ASSEMBLY. VERIFY EACH MANIFACR RIGS INSTALLATION REQUIREMENTS.
,r FIRE DAMPER
RETANPE ANGLES ALL (AL FOUR 51DE5J
SHALL BE AC-CORDING TO DUCT SIZE:
-44. U' TO 45"
- 2.x16 GAI E, GREATER THAN 45"
ACCESS DOOR •
BOTTOM OR SIDE
a.. SHALL BE
MINIMUM E GA UP TO 36"
AND 14 GA OVER 36"
2. DAMPER SHALL BE VON AND BE POUERED OPEN. DAMPER MOTOR TO
BE CONNECTED TO FIRE ALARM SYSTEM DAMPER SHALL CLOSE UPON ANY
SMOKE OR FIRE ALARM M BUILDING
OUTDOOR
AIR INTAKE
RTU CONDDISITE ORAN
CRJD=J.SATE TRAP PER DETAIL BM-6
B RELAR BAS PER 3M -1, 5M -1
(TYPICAL SPELT ANA RDUFW
THERMOSTAT WRING
BALANCE. DAMPER OPPOSED
BLADE DAMPER TYPE
TOP CF GRILLE
3'-0" APE
CONFER FAN. /Bl" HVAC CONTR)
INSULATED PETAL CISB Br AARBNT
1141FACTARt 5. CURS DETAW ON
ARCHITECTURAL S.T.
P.'SIATE CARD CAVITY
WNH FBERGLASS BATT
MSUATDN
E. DETAIL 5M -1
POTTIER WIRING UP THROUSH BASE CF WIT
TO BREAKER MONTED ON SIDE CP UNIT
L ROOFTOP INT AND CURB RM.., UNDER
NATIONAL ACCOh75, SCE R9395L115TA' L WED.
ON ARCHRECIUR% SHEETS.
2. WIT AND QM META ED BY HVAC CONTRACTOR
FOR DETAILED PFORMATION REGARAPG SPRY AND
RETURN P. M%SE 6M -1_
Typical Rooftop Unit (Supply/Return Plenum)
j SCALE: N.T_S.
TOP CF WALL TOP OF COYF ESSCR ROOM TO
• 8'-0" APP. —. N...., / REMAIN OP'ELNO MUG.
:EL
4 1Section at Air Compressor Closet
SCALE: N.TS
ROOF DECK
ROOF MEMBRANE RAMS IE
(Br ROCFEW
ROOF NSLLATION (BT
NOTES-
T
BAR JOIST
L THIS DETAIL APPLES TO ANr MECHANICAL OPENINGS LARS. THAN e"
IN ANY DRECTK N, OR 100 SQUARE NOE5 OR LARGER
2. ALL CURBS METALLED BY HVAC COMB EOJIRMBNT PENNED UNDER
NATIONAL ACCOMS WILL COPE WRH ROOF 01.5. ALL OTHER CUBS TO
BE R1RNI5HED BY HVAC CCTNTR
3.
14VAC CONTR SHALL LEVEL ALL OUR05.
4. ALL BAR .A.R BARS INSTALLED BY HVAC CONTR ROOFTOP WR
BURGLAR BARS RRNISIED WTH WIT, ALL OTHERS FURISED BY HVAC
CGNiR
R
BIRD SCREEN
MOTOR/ED OPPOSED-BLADE
DAMPER
I° EXT.JOR INSULATION
2° DEEP DRIP PAN SOLDERED
WATER TIGHT. COAT BOTTOM
WIN ONE LAYER OF BITUMASTIC
Exhaust Fan Roof Ventilator
TOP OF GRItlE
• I-6" APP
DUGNORC
....II. OF OAS AREA
BY HVAC CONTRACTOR
LEVEL'. CF CURS BY
HVAC CONTRACTOR
SEAL AND FASTEN DUCT
TO FRAME WITH SCREWS
51..2 BARS
DUCPLOTEK (SEE RANE)
0
S" PUNAIM
- + AAR PVAKE
RN COFD35ATE DRAM
CONDBEATE TRAP PER DETAIL EPI-6 !I
ROOF DEO( 7{�
P OVIDE 547K- DETECTORS PER
LOCAL CODES. NSTA2 ®Br WIC
CONTRACTOR AID RRNI NEE BY EC.
ITT, RIPPLY N RETURN/
PROVIDE ACCESS PANB-5 TO SEE I
DETECTORS PER LOCAL CODES_
(TYPICAL SPELT AND RETURN?
6 Rooftop Unit Supply and Return Plenum Detail/Specifications
SCALE N.TS
CURB t FLASHPG BY HVAC
CONK PER DETAL 5M -7
ROCF DECK,
SI GL AR BARS AS RECUIFED,
FFR DETALI3M -1
■
INSULATE E OERNAL1T
MNMM CF
FROM ROOF MEWS
TU I G VANES
q Unit Heat
rn9q
I IYOF '
APPRC,''ED
FEB 1,
PERMIT SET
12/08/99
rev
A
A
0
A
A
A
date
OTaV OF
1
PERM, .r, EE
SCALE:
AS NOTED
Q
m l
MECHANICAL
DETAILS
MARK
M=GR
MODEL
TYPE
ALH
V H T
( G)
MOTOR
E.. -.TEN
FLUE
REMARKS
HP
RPM
'JOLT
UH -1
P.EZNOR
SCB -150
NATURAL GAS
1500 11.
120
60
1/4
713
120
SiLR_: INSTAL
OVAL
0U
UH -2
REZNOR
SCB -150
NATURAL GAS
1500 F, 5 C
120
60
1/4
713
120
STEREO INSTAL
6" OVAL
0 L}
UH -3
REZNOR
SCB -150
NATURAL GAS 11500 1 150 120
60
:/4
713
120
RECE'4'T1G
5" OVA'-
O
MARK
LOCATION
MFGR
'd ODEL
STORAGE
CAPACITY
(GALLONS)
RECOYRY E
� 1000 RISE
(GALLONS /HOUR)
NUMBER
OF
ELEMENTS
HEAIGR
ELElAENT
CAPACITY
REMARKS
WH -1
JANITORS AREA
STATE
PV- 12- 10MS -K
MINIMAL
CFM O.A
ESP H.P.
1
1650 WATTS
ri C
'NH-
STEREO INSTALL
AG $TAI ?H
ELJF -5
6
6
7
7500 WA,
2200
QUANTITY
MARK
MFGR
MG7EL
NOMNZ_
Jh..1._
WEIGHT
` LBS)
HEIGHT
(wTH CURD)
FAN SCION
DX COOLING SECTION
GAS HEATING SECTION
' L
SEER 0.4.. RATING
RiyMNS
NOMINAL
CrM SA
MINIMAL
CFM O.A
ESP H.P.
TO CAP CIT.
8 NH
SEN4: - PACITY
BNH
TYPE
NPUT
B1U
1: TH11T
BTOH
$TAGS
9
RTU'S 1 -9
THANE
YG915
.125
2200
65"
5000
965
as 3.0
151,000
109,900
NATURAL GAS
150,000
122,000
2
B.3 EER
00®00®
7
RTU-11
TRANE
YC012 2 C'
C
2000
65"
=.000
120
05 2.0
132,000
. 94,000
NATuRAL GAS
150.000
122,000
2
11.5 ER
0 ^ 00000
2
RTU -1D, 15
TRAS_
•'13CL1C4
5
1100
1 50'
1960
90
55 3/-
60,000
35,000
NATURAL : GAS
90,000
73000
t
120 SEER
® ®000
RP0-16
TRANS
'!x'0370
3
■ 950
48' ■
1200
120
0.5 1/5
41,000
32.500
NATURAL 'GAS
80000
65,000
1
120 SLR
O 0000
ROL'S 12 -14
TRAM
scC•O :SF'
1 - 1/2
350
4S
AGO
100
0.5 ' 174
i 1,,o,
- 1 400
NAP.+RALIGAS
50.000
' 40,000
1
lac SEER ■ .
' 7
X0000
MARK M
M: GR M
MOD= C
CFA 4
.,.4 =P. DIRE _
_ 1
1AOOR
0'n `✓= H
H P. C
CONTROL .
.. R[,. S'cRVED f
flENARKS
t,
_h
STANDARD ABBREVIATIONS SCHEDULE
iRiO4 DESRdFLT@C .. M"I T"T OESCRIPTION
ENKE REA NG, 'ENTILATING, A/C
N
INSi LARON ■
INYN T
JOISTS
MAXIMUM
M G- 10441C,
MD JM
MaZA.NTINE
MANUFACTURER
MN3ZUM
MOUNTED
NOT TO SC,
00 AR
C- 4IVG
ES.. OP
MB D'.
P UMBING
RESSUT
POAER POO MINP.LATOP
POINT
ROOF ORA'N
REFERENa
R VN
CST?
REQUIRED
- N N IN .DER
RAIN RATER LtADER
BANITARY
STATIC PRESSURE
S; PLY
= N1?_RAERE CONTROL
T17�=RANRE.
FOOTING
liGt, TB JOISTS
THRU WEE QF OASTS
VOLUME DAMPER
1EH!C F
I , rneL
FE E
..7u aQQ=
I 001;-
WALL HYDRANT
t...,_.,,,guig„,s,,,,,,,,,,„,,,,,,,„„,,,„,„,,,„„Hr,..,„„,„...,
t,
_h
'Horizontal Restaint
SCALE: N.T.S.
a UNIT TO BE 4500/3 PHASE
UNIT TO BE 205V, PHASE
a UNITS SHALL BE 120'V/I PHASE.
WIDE b GAUC� PLO?
BENT TO SHARE
HMR1P1 4 -14x1^ SELF -TA PT.
SCREE. (6) F ER STRAP.
L 115E(O STRAP PER SIDE
2 STRAP 141ST EE PANTED SERE R CONTACTS
OATH ALLPOIPI RAIL
NEW ROOFTOP UNIT SCHEDULE
EXHAUST FAN SCHEDULE
UNIT HEATER SCHEDULE
� Tr ERMOSTAT. LC �( \G C04 4M1.. C'JN'O-'
Vn41NG EY HVAC CON KACTOR
0 PROVIDE MOTORI r, CAMPERS i.N ROOF CIURB Gr, VS.
OZ UNITS SHA1 BE 1150/1 PHASE.
UH -4 RANOR SCB -150 NATURAL GAS 11500 1ISO I 120 60 1/4 713
ELECTRIC WATER HEATER. SCHEDULE
` SEE DE TAIL 2 6 FOR
W'P.TE4 PEAT -
=:.
IN BOIi SL ?PLY &RETURN STAGE a NITS TO PRT / STOP THROVCR
.EC UNDER D'VI510ti `.fi AND INS A1E0 EMS OPUMUc M STAP.T PROGiFM
®INERLOCK 'b1`H JOHN BY ELECTRICAL LONTRACTOR
® LINE VOLTAGE 000LING THERMOSTAT FY HVAC LNTRACTCK
I I I
®. STS JNT Ea CCM AIR "
`✓ IN .FROM 'H GL :TSID..
120 RECELN,Nc
CONN7ECTICN PL1TE-
TO ROOFTOP WIT
nMl7J'1(22
CLAFFS PER END
AIRCRAFT r�w�
MALL TY31T
ETE PO-
THMIBLEY
AT LOO'S
5T�1
NOTES:
UNIT SATE RAIL
OR LETFG LUG
L USE nM411 CF y" DIATETER CAELEnAID711
OF I PLACE PER SIDE OP WR
ROOF OMB
LOAD DISIREETICN PLATE
CR!Fr
Q2!!c d'L=11.L'-
,ETDEi6 Pl,(1
PLZE EE1TTO SHAPE
ATTAOI TOWS
WV TcMSCREW
r/1A191P1
ROLE
wxTEPE
Us CU FELD -JOAN PLATE PER SIDE
MOLD -XQI PLATE HET BE PANTED WERE TT
CaiTAGASA AL M. RAP-
tESDRE65PER HOLD -DOUN PLATE
r14,'!O
B RDI G DESIGN DATA
3JPGOF DES. - u.,, S .
511 x:
S ie -- &At r0169r WR
D GPrE O . e U Tub,
(:'CL
THERMOS-AT s -CV.NE -- _:.- . -.
kv.c
SAME,
SCJ -rvNiG ENTRY
-. DOE,NG LOAD AT BLOB FM
ROcFrOP WIT
ATTACH TO WIT.
(4) 50 p" TEC P7E115
MOOD NAILER
NAT. HEATERS
VA4 AHIE AIR VOLUME...
S. EWER UNIT
INFRARED HEATER
SJ'N'D ATENUATOR
EI. ECTRIC HEAT
B.. TOP ;MGT
ROC, GOP UNIT
PD., ROOF .N i LATOR
/ / / /// DEMO EXISTING
'.N CONNECT TO EXISTING
GATE VALVE
-wr- BAL VALVE
- - BALANCrv2 VALVE'
- F -CPECK VALVE
--p-- GAS COCK
-011- GLOBE VALVE
ANGLE VALVE
-'p- -AUTO CONTROL VALVE (ACV)
-yp�- SELF CONTAINED ACV
-- 3 WAY CONTROL VALVE
- BACK F!0'N PREVENT.
--0— fOW CONTROL DEVICE
-1�y- -FLOW INDICATOR
(-WALL HYDRANT /HOSE BIBB
- -p
PRESSURE REDUCING VAL,
Hip T RELIEF VALVE
-g -FLOAT A OHE- NOSTAAC TRAP ASSEMBLY
THERMOMETER
0- PRESSURE GAUGE
- IeI- BUTTERFLY VALVE
TRIPLE DUTY VALVE
- PRESSURE REGULATOR
LLNW METER
LEVEL TRANSMITTER
G PRESSURE INDICATOR
TEMPERATURE INDICATOR
� • PRESSURE TRANSMITTER
EMPERATJRE TRANSMITTER
-H STRAINER
- CONCENTR'C REDUCER
« FLEXIBLE CONNECTION
- PITCH PIPE DOWN
-X-- PIPE ANCHOR
PIPE GUIDE
un o- FLOOR DRAIN
BO -ROOF DRAIN
13 OVERFLOW BRAIN
0- FLOOR CLEAN OUT
xra II- WALL CLEAN OUT
SUPPLY DIFFUSER /REGISTERS
DIFFUSER TYPE DIFFUSER TYPE
FACE SIZE NECK SIZE
D -12x6
300 �1 200
GEM I CFM
DAMPER
DIRECTION
CF IHRCW '
LINEAR SUPPLY DIFFUSER /REGISTERS
C DIFFUSER TYPE
S 1AMMEN510NS
B -
500
CFM
PIPING SYMBOLS
DAMPER
AIR DEVICE ABBREVIATIONS
- N u EZ E "FILING MOUNTED SUPP BE=RLI E - REIURN / EXHAUST REGISTER
- LINEAR DUCT MOUNTED SU ?PLY D ;FFUSER � - RETURN /E %HAUNT ?RANSFER GRILLES
= Si= STORM DRAIN
- ST- STORM DRAIN - EXISTING
WASTE - BELOW FLOOR
- WASTE - EXISTING
WASTE - ABOVE FLOOR
C - CEILING MOUNTED RENRN /EXHAUST GRILLE
D - SUPPLY REGISTER NOTE: REFER TO SPECIFlCADGN SECTION 15880
FOR MANUFACTURER & MOCEIS
UNION
ELBOW
Q- -ELBOW UP
C- ELBOW DOWN,.
- -�- TEE DOWN
O TEE JP
B.- PIPE CA=
'O VALVE IN R SR
- SOW- SOFTEN(: COL. WATER
- CA - COMPRESSED AIR.
WS CONS LASER WATER. SUPPLY
CDR CON :CENSER WATER PEE.
- CGS- CALLED GLYCOL SUPPLY
- CGR CHILLED GLYCOL RETURN
- CGS( - ° )- NIL MBEEED CHILLED GLYCOL SUPPLY LOOP
-.RUN N MB. R CHILLED GLYCOL RENRN LOOP
----- -- CWS C.EILLED PROCESS WATER SUPPLY (NO GLYCOL)
LHIL.D PROCESS WATER RENRN (NO GLYCOL)
- -Old HIONIZED WATER
'1_00 DOMES - IC COLD WATER
JHW COMESY HOT WATER (1005)
DHWR
DOMES PC HO WATER RECIRCULATING
-180 D180HW - DOMESTIC HOT WATER (18D2-)
F iIRE?ROTECTION MAINS (SIZES NOT LISTED)
NATURAL GAS
-BPS LOW PRESSURE STEAM
- 19R- LOW PRESSURE REMEH
THINS- HYDRONIC WATER SUPPLY
HWR HYDRONIC 'WATER RETURN
- HGS HOT GLYCOL SUPPLY
- HGR- NO' GLTC'_" RETURN
- HGS(#)- N1, :'.L,,._0 COT GLYCOL SUPPLY LOOP
- HGR(p)- NUMBERED HOT GLYCOL RETURN LOOP
N7- NITROGEN
- P1CGS 1st- PRIMARY CHILLED WATER LOOP
-F,GR 1st- PRIMARY CHILLED WATER LOOP
-P2CGS 2nd- PRIMARY CHILLED WATER LOOP
- P2CGR 2nd- PRIMARY CHILLED WATER LOOP
RO REVERSE OSMOSIS 'WATER
-SCW- SOFTENED COLD WATER
- SINS- SPRAY WATER SUPPLY
- SLUR- SPRAY WATER RETURN
-VAC- VACUUM
RETURN /EXHAUST GRILLE /REGISTER
TYPE OFRECDOIJ OF AIR FLOW
24x2
SIZE
PAT
F GRILLE
PE
FACE s¢E
0
GFM
DIRECTION OF AIR FLOW
r�q � 02 58
ti
SQ. FT. CALLS
40,602 SF
nay 3,227 SF
NA 1,171 SF
0005 45,000 SF
CONCEPT:
C4.5 -45
CONCEPT DATE:
09.01.99
EST. MATURING DATE:
EST- G.G. DATE:
I F'
ia7
Q
�z3
dw
D.E3x
PERMIT SET
12/08/99
rev. date
A
A
0
A
0
1
flEDE1VED
Cf1Y OF TUKWIV
PERMIT GEN■Et•
SCALE:
AS NOTED
.r'
MECHANICAL
DETAILS
M -8