Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M97-0020 - BOEING #2-80
Boein z-80 M't7 002.0 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M97 -0020 Type: B -MECH Category: NRES Address: 8123 EAST MARGINAL WY S Location: Parcel #: 000160 -0020 ,Contractor License No: BOEINC*294ML TENANT BOEING #2 -80 . 8123 EAST MARGINAL WY S, SEATTLE, WA 98124 OWNER BOEING PO BOX 3707 - M/S 1F - 09, SEATTLE WA 98124 CONTRACTOR BOEING COMPANY P.O. BOX 3707,. M/5 SEATTLE? WA 98124 CONTACT LARRY ALLEN..`: Phone: 206 544 -1644 P.O. BO.X M/S -35, SEATTLE, .WA 98124 ****************************,**'************* * * *k * * * * * * * * * * * * * * * * * * * * ** * * * ** Permit Descri INSTALLNEW'AIR HANDLING UNIT, REPLACE EXISTING. UMC Edition: 1994 Valuation: 11.,500.00 Total Permit Fee: 42.81 (206). 431 -3670 Status: ISSUED Issued: 04/01/1997 Expires: 09/28/1997 * *******'************************ * ********** * * * * * ** * * * * * * * * * * * * * * * * * * * ** * ** Permit - Center Authorized Signature Date I hereby,cer.tify that I have read and examined.this permit and know the same to be true and correct. All provisions of law and ordinances governing, this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel. the 'provisions of any other state or local laws re construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature:_„__ Date: . . `�`� l 2 Print Name: 1� n/ _ Title: __ _p!k.t.LfLs_Altabi fi e V' This permit shall become. null and.void if the work is not commenced within 180 days from the date'of issuance, or if the work is suspended or abandoned for a period of 180 days from last inspection. MARGINAL '` S CITY .0f- TUKWILA: Addes^ : 8123 EAST $u ite Tenant: : BOEING #2 -30 Type B -MECH : Parcel # :" 000160 -0020 k1k *•k : i4•4 4 4 * **•4•k*•k'k•k•** * ** * *•k k *•k* 4**** k *•4'44 **•k k•k k k* k•* * ** ** *•k•k * **•*-k•k•k *'k *•k ** Permit-Conditions: 1 : . No . changes m i l l be made to the plans unless approved by the Architect • or Engineer and the:, Bui iding" Division. 2 ; A "1 i permits, .inspection records and approved plans ;shall . be available at the',j,ob site :prior to .: the:: star °t_ f any con- struction. Thee •,d,o'cuments are to :be maintai`ned.• and avai l able until. `final •"inspe.ct.lon approval is g,ranted::" .. Al 1 canstruc l.on to be `done in conformance ..with approved plans and ,regii i reren tr . the Uniform` Bu i 1 d,i ng.,Code ''(:1994 Edition) as. amended, Uniform "Me"chanical,.Code-14994. Ed.it.ion), and Washington State Energy Code (1994 Edition).. 4 .. Validity f of Permit . The Issuance ,' of a permit or. of plans;, specifications. and computat°,ions sha11 not be con- strued . to , be a permit for,' Or an approval of + any v.io,latian of any of•"'the provislo.ns of t.ha.::b•ui lding code or of any othePor.d"in'ance' of the juri s,d•i ct 1"on.,. No permit presuming giv,e.autl ority to violate. -.or „cancel the provisions' -of thi code.7sha11 be ,`valid;' MANUFACTURERS INSTALLATION INSTRUCTIONS REOUIREG ON: SITE FOR THE INSPECTORS Electrical: :permits. sha %1T be' obtained'-through the Washington State Div-,isio.n of Labor. and . Industri ='e s" an(t`al1 ele,ctri.Cal wol4Awi 1 T";;� inspected ;by ;that agency •..(24`$ -6630) . .rat: ... Permit'-No: M97- 0020. Status:: ISSUED Applied: 02/04./1997 •Issued.: 04101/1997 Project Name/Tenant: n po{� ■ 1 11 ZW'riotA N Ir 1 O • A - - . a ez ` - ') i Value of. Construction: 4 /1 6v Site Address: � ^ �3 1 , a"- ti tit � y State/ , Tax Parcel Num 0r- oo z e Property Owner: 217.P Ia7( 0bn�iy)6(c:t• A)rpla Phone:. Sqy 16 �1q Street Address: 1 O City State/Zip: Contact Person: 6V1Pki &1 Phone: syy ��UI Street Address: � r, D , ►jt7 57o N 5 City State /Zip: I -35 5 x 9. �S5 5o 3 Contractor: fi0.-6 / G C 11 i i Phone: Street Address: City State /Zip: Fax #: Architect: o.2 / l Phone: Street Address: City State /Zip: Fax #: Engineer: P,; 0 .2 /' --) City State /Zip: Phone: Fax #: Street Address: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to a cone: rl 5r n i /-1-'i( e a��� I u 0-vu U n L , . , i � I> > - _. (' � ')(I S Will there be storage of flammable /combustible hazardous material in the building? ❑ yes . I.3 no Attach list of materials and storage location on se•arate 8 1/2 X 11 •a.er indicatln. •uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition ❑ Fence 53 Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO:. Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF T'IKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 F. - STAFF USE ONLY Project Number= Permit-Number:. Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. .APPLICANT REQUEST..FOR MISCELLANEOUS PUBLIC WORKS PERMITS; • ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private ❑ Channelization/Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt it Size(s): ❑ Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling 0 Deduct O Public O Water Only W ATER METER DEPOSIT /REFUND BILLING: N ame: Address: MISCPMT.DOC 7/11/96 Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Application t g y: (initials) 0 r+ BUILDING OWNER AUTHORIZED AGENT: SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Above Ground Tanks/Water.Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 Signature: 7 GZ �_ Submit checklist No: M -1 Date: � 2 , 9 Awnings /Canopies - No signage Print name: l_ y n._14 i ' 3 lu`1 � 1,1C-' 0 Phone: City /Stat eI << Lf b ,� 6vl (.1. Fax # 55 l2 c S 0 V: - 1 Address: n M _, _3 i n ALL MISCELLANEOUS PE - IT APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER D CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Above Ground Tanks/Water.Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 Submit checklist No: M -9 El Antennas /Satellite Dishes Submit checklist No: M -1 Awnings /Canopies - No signage Commercial Tenant Improvement i Permit ® Bulkhead/Dock Submit checklist . No: M -10 0 Commercial Reroof Submit checklist No: M -6 0 Demolition Submit checklist No: M -3, M -3a 0 Fences - Over 6 feet In Height Submit checklist No: M -9 i n Land Altering/Grading/Preloads Submit checklist No: M -2 ® Loading;Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 Mechanical (Residential & Commercial) Submit checklist No M -8,. Residential only. - H -6, H -16 Submit checklist' No: H-9 Miscellaneous Public Works Permits ri Manufactured' Housing (RED INSIGNIA ONLY). Submit checklist No: M -5 f Moving Oversized Load /Hauling Submit checklist No: M -5 0 Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 El Retaining Walls - Over 4 feet in height Submit checklist No: M -1 0 Temporary Facilities Submit checklist No: M -7 i n Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 El Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PE - IT APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER D CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 A**** OF-JUKWILA WA' ITY ****:**A4kk*****03aaNINXI)*********k**k******A***N* TRANSItlIT.Number: R9700559 Amount: 4281 04/01/97 13:46 Payment Method CHECK Notation: BOEING TRUST ACC Init: SLO TRANSMIT Permit No: M97-0020 Type: B-MECH MECHANICAL PERMIT. Parcel No: 0001,60-0020 Site Address: 8123 EAST MARGINAL NY S Total rees: 42.81 This Payment 42.81 Total ALL Pmts: 42.81 Balance: .00 *********k**k**********A**h*******A**********************k**A** Account Code 000/345.4330. 000/322.100 Description PLAN CHECK - NONRES MECHANICAL - NONRES oda‘vn5 C-- PV coo Doo S10 ..ct 0 3. Amount . 8.56 34.25 • (W5 04/02 9717 TOTAL 0.00 Project: 0 Vi e'?' z � Type of inspecti • n: . / nc Addres 5, ` . 1 vie. Date called: a � Special instructions: wanted: ?— Requester: Phone No.: PL. INSPECTION NO. COMMENTS: Inspector: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. lii�43.,rd ?: r $42.00 REINSPECTION F'E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. ( Receit No.: Date: PE MIT NO. (206 X31; 5670 Corrections required prior to approval. Date: Pr t{ Li ..t. 2 -8'o Wv � Type of Ins t on d , 1ti Date called: Z �V 11 ' c E. M,Aizon A1 Special instructions: ci•-•`-"'' Date wanted: ¢, 1 p.m. Requester E F F , g )e42. Phone No.: p in Approved per applicable codes. I I Corrections required prior to approval. • MMENTS: -7 ;1 � INSPEC CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector; Receipt No.: ION NO. INSPECTION RECORD Retain a copy with permit 4.4 Date: Date: ' 61 - CO2 PERMIT NO. (206) 431 - 3670'• �] $42: REINSPECT! Q ( FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection.. PROJECT NAME BOEING #2 -80 DEPARTMENT: BUILDING DIVISION PPPr• alcL9 a PUBLIC WORKS REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F CORRECTION DETERMINATION: FIRE PREVENTION APPr a/o(/ STRU CTURAL DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE Q NOT COMPLETE E COMMENTS APPROVALS OR CORRECTIONS: (ten days) DATE DATE Qtnntk C.o4no*o CJ$?9 PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER M97 -0020 DATE 2/04/97 P t G DIVISION ❑ PERMIT COORDINATOR S DUE DATE 2/06/97 NOT APPLICABLE 0 TUES /THURS ROUTING: PLEASE ROUTE E1 NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF U (If routed by staff, make copy to master file & enter Sierra.) APPROVED n APPROVED W/ CONDITIONS NOT NOT APPROVED (attach comments) Q REVIEWERS INITIAL DATE DUE DATE 2/20/97 DUE DATE APPROVED I I APPROVED W/ CONDITIONS fl NOT APPROVED (attach comments) 0 (Certification of occupancy required. City of Tukwila Fire Department February 6, 1997 Fire Department Review Control #1497-0020 Re: H.V.A.C. at Boeing /2 - 80 - 8123 East Marginal Wy S Dear Sir: Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be Installed in accordance with the manufacturer's installation instructions. (UMC 608) 2. Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) 3. In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) The installation of wiring and equipment shall be in John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57. 54404 • Fax (206) .57. 54439 IMO Yours truly, City of Tukwila Fire Department Page number cc: TFD file ncd Headquarters Station: 444 Andover Park East accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) 4. When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 5. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. The Tukwila Fire Prevention Bureau John W Rants, Mayor Thomas P. Keefe, Fire Chief Tukwila, Washington 98188 • Phone (206) .57.5-4404 • Fax (206) 57.5:4439 Subject: Larry Allen Replace A/C Unit, 2 -80 Building Job # 966178 Here is the information about the new air Shawn Gavras 6-8W5K, MS 1R -08 655 -1232 Attachment Pace Model Airflow Outside Air Cooling Load Cooling media Water flow rate Motor Power 19 -35 handling unit per your request: SCF -97A 1000 CFM 100 CFM 33,515 BTH Existing chilled water loop. 7 GPM 1-1/2 HP 460 -3 Phase 60Hz. I have attached a copy of the new unit's specifications. If there are any further questions, please call. RECEIVED CITY OF TURIN HA FEB 0 `k 4997 PERMIT CENTER � •ao0o • Job Name: S.C.F. UNIT OPTIONS SCF Tag: SCF Qty: Description: Size: Cabinet: Mounting: Insulation: Access Panel: ETL: S.C.F. Mixing Box Section OSA: Damper. Linkage: RA: Damper: Linkage: S.C.F. 2" Filter Section Filter Size: (1) 16 x 25 — Filter Sets: 1 Filter Gage: Magnehelic S.C.F. Coil Section Section Type: Coll Type: Coil Media: Fin Height: Fin Length: Rows: Quantity: FPI: Fin Material Tube Material: Return Bend Mt!: Size: Type: Drain Pan: Blankoff: Technical Information: Entering Air: Leaving Air: Ent. Water Temp: Lvg. Water Temp: BTU: GPM: Face Velocity FPM: PACE — PUPS v3.11 Submittal 12/12/96 S.C.F. Housed Fan Section Fan Size: CFM: TSP: BHP: RPM: BOEING PLANT H AHU -1 REVISED 1 WIND TUNNEL EQUIPMENT COOLING 97 A Floor 1" 1 -12# FG Top Yes Steel Damper Parallel Steel Damper Parallel U8 1000 1.50 .93 2221 75 65 55 54 33515 6,7 397 2.78 20" (7 -8 row) Cooling Water /Glycol 16.5 22 5 1 10 0.006 Aluminum 0.025 CU 0.049 CU 1" Steel MPT Standard 16 GA G -90 Galvanized Phones 65 . . IL 13:59:22 Unit: Page: 1 In *V MAY .:l Fan: Wheel Material: Lube Lines: Motor: 3- Phase: H.P. Voltage: Mounting: Side Access: Electrical: Wire Motor to External: NATURE SAVER" FAX MEMO 01616 '° SI f1 Wh '- v1^i$ CoIDept. Dile r L / V7. 1 rol / °�peS . 7 From r W /i Co Vt GT" 1 • Phon► / Z — 14( 7Z Steel Nylon, extended to Fan Frame Magnetek ODP E+ 1800RPM 1-1/2 460 -3 Phase 60Hz Motor Internal, Spring Isolated Left Hand Door No motor wiring 7 7 3Z. 1 $� 1 7 ■ 7 PAGE PoX44 -(F L 1 bp) P1 (Airs) 7 7 2 0 'Ar 5 78 1 [�vA (/77s) 1 I►� I~cc F65 L• zo DS DRAWN WV Johnson- Barrow, Inc, ki)7 w Suite 201 °M r I 1725 Watlsks Avenue North Sattls, Washington 981 80A`fi A< TS DRAWING fi ro. A Coil tea. w COIL MODEL #: NAME: • COMPANY: JOB NAME: DESCRIPTION: JOB #: 105 CW - 16.5 X 22 - JDW JOHNSON- BARROW, INC. Boeing Plant II Wind Tunnel Equipment Cooling Standard Air Flow rate (CFM) Actual Air Flow Fate (CFM) Elevation (Ft) Density Ratio STANDARD CFM Entering Air Dry Bulb Temp. (F) Entering Air Wet Bulb Temp. (F) Leaving Air Dry Bulb Temp. (F) Leaving Air Wet Bulb Temp. (F) Entering Water Temperature (F) Leaving Water Temperature (F) Total BTU /HR for Each Coil Sensible BTU /HR for Each Coil Gallons per Minute Each Coil Gallons per Minute per Feed Coil Face Area (Sq. Ft.) Standard Face Velocity (FPM) Actual Face Velocity (FPM) Rows Required for 8 -FPI Rows Required for 10 -FPI Rows Required for 12 -FPI Air Pressure Drop @10 -FPI (In WG) Number of Tubes Fed (circuits) Number of Passes Water Pressure Drop (Ft. of H20) Connection Size (In) Rated in accordance with ARI Standard 410 -91. Me spacing coil hand 1 fin material II of tubes fed I of passes MW 1Inar Ina/lob.; cob type fin Night fin length 0', g. 10. 12 1.0.0. 10. 12 blank 1.5" spacing tia t)" snesinn SeleArlon V4.1 `" Thu Dec 12, 1996 12:11:55 A- 086 HW- 24x72- • 3/18 A 15/6 t it of patter e + I of tubes fed *o 93 aa2roa HW L •A.000 "rippled alum. r '12.106 fi.dgM 12.72 S. SD. sn0 lekft 75.0 65.0 55.0 54.0 45.0 55.0 33515 21800 6.7 2.2 2.52 396.7 396.7 5.33 4.69 4.25 Specified Capacity 1000 1000 0 1.000 Total Capacity 1000 1000 0 1.000 75.0 65.0 54.6 53.6 45.0 55.3 34513 22203 6.7 2.2 2.52 396.7 396.7 5.68 5.00 4.53 0.54 3 18 3.72 1.00 'SUMO* *max, length 120' CW water 000Nng HW Mater heating WO titer booster DX direct etrpansbn I standard steam ID steam distrbuting snit eteYn ActrihkAnn face sn.t cann 5- YLTxStwlY: Att,1 i::.d . - r,t N.f ✓�i:xi:2.`.6 - a � 1 -� Fan Performance V4.1 INN ' NAME : JDW COMPANY: JOHNSON - BARROW, INC. JOB NAME: Boeing Plant II DESCRIPTION: Wind Tunnel Equipment Room JOB #: Fan Selection Tag - Fan3 Model - Housed VC Size - 8 Configuration - SWSI Operating Conditions Tag - Op0 Air Flow Static Pressure Elevation Temperature Density Performance Actual Air Flow Total Static Pressure Fan RPM BHP 0 Std Density BHP 0 OP Density % Peak SP Mechanical Efficiency n. i ..rttrr.Y.c.:.�ss�,a.sr•w; r•‘,.,nwa,rwrme - 0,,1 1000 CFM 1.50 in WG 0 ft 70.0 F 0.0750 lb /CF 1000 1.50 2221 0.94 0.94 58.5 % 32.5 % CFM in WG Wheel Construction Construction Rating Max. RPM Wheel Width Wheel Diameter Tip Speed Thu Dec 12, 1996 12:35:24 Class 1 2844 100.0 8 8.12 4796 Sound Power Levels (dB Re: Octave Band 63 125 250 500 1K Bare Fan 81 80 79 77 75 Bare Fan sound power levels are derived from data collected on representative fans in accordance with AMCA Standard No. 300. "Bare fan" levels are as measured in the laboratory with no plenum correction. Tag #: Fan3 10E -12 2K 4K 76 74 Watts) BK LW /LWA 71 86/82 February 10, 1997 1- 9604- DBW97024 To: Larry Allen 19 -35 Leonard Astemborski OH -13 Terry Beals 63 -04 Rick Ford 2R -71 Len Knecht 63 -04 N. Konwent 5H -26 John Murdoch 89 -14 N. Pestisme 63 -04 Lori Pitzer 2R -71 Mike Sullivan 3U -EH Gary Taller 46 -87 Rex Turner 7R -35 Subject: 1997 Washington State Contractor's License for The Boeing Company Enclosed is a copy of the Washington State Contractor's License for 1997. This license expires on January 1, 1998. Please contact me if you have any questions. D. B. Weigelt 1 -9604, 1F-09 (206) 655 -4535 Enclosure de„ ✓frWR344r✓!.%tt31,?1 iyy ervi.P.T✓P✓.44,0 ljd?tYNN• %viA4VelevrN✓✓f! evol if,?!! r✓ ry)*Wej.!rG ✓Niii6,Wr1H.•M! r641446 tve, DEPARTMENT OF LABOR AND INDUSTRIES THIS.CERTIFIES THE QN NAMpO HEREON IS REGISTERED AS PROVIDED BY LAW AS A l i% (l i 11i '. .�•.•: L ...... .. .;p1.: ♦ _ l4 I tZb S { !. L .T. r i 4.'h.T• ER:STI EXISTING DUCTED RETURN AIR GRILLE 184"'x36' IRG ID" DIA 500 CFM (TYP-2) 1M17. 111519 KIST. 28.12 1W1n1a 12/12 12012 NECK ADO CO ■ 1 r ��1 5 ,. I 1 4X14 iRE 1' :1011 -IUP 34X114 MANUAL VOL LIME 4608 `46$14 1 26010 I] ',26018 /14016 6I•rj Jlllls2P o ' LIa I'2 X16 300 CFM jf W 50x30 p Dx OOIL 36x24 STEAD COIL 7 ROD 15/26 1036 DX 061E 1 ROW COOLING COIL 18" FLEX 12012 EXIST. 28x12 NEN DUCTED RETURN AIR GRILLE CITE oo �o BY REPLACE A/C UN T J #966178 S. GAVRAS PC STATION A/C J#770270 -01 005 REVISE DUCTWORK,Jj/770173 ADD HEATERS J# 780155 -00 UPGRADE ELECTBUILD UP AREA J1780479 - 18 4. R=S 40/16 240,24 0/A INTAKE APPROVED ORE 1/11/97 4/19/88 9/08/8B 2/16/89 6 -20-89 3 -30 -88 3 -30 -88 3 -30-88 ACCEPTABILITY 1116 DESIGN AND /OR OBTRLE HVAC PLAN SnE UST REPRON 1M JOB NO. 770173 K 1/11/97 cows rvD. 3088 (.OR CGNT IJU. VI OF DUEIWJHF S'EE PARTIAL 'LAN, I M1 1v, r�wr:;r� SY4 11X6588 F INCREASE AIRFLOW Jr710073 G REPAIR WATER LEAKAGE J#710305 -00 H CHANGES IN AC/HEATING 31730007 - 00 - AS - BUILT J FROM HEAT TO OFFICE 10 740051 -CO 32/1 i4 /10—, 7 10/6 c Br 008 MOB MR 5/23/89 12/9/91 6/22/93 12/8/93 7/22/94 PLAN V I NF SCALE: i /8" 1'-o Adic Bv4 arAIW FACILITIES DEPARTMENT O.A REFERENCE DRAWINGS 2.80 -M1D 2.80 -1M519 2.8D -M315 EQUIPMENT SCHEDULES HVAC SECTIONS 6 DETAILS AHU 1DC7 CONTROL DIAGRAM APPROVED LF CEINP OT ROW/ :nERI /IJSTAT CONSTRUCTION NOTES REMOVE EXISTING RETURN GRILL AND ASSOCIATED DUCT. PATCH AND PAINT CEILING TO MATCH EXISTING. COVER ASSOCIATED HOLE ON MEZZANINE AS REQUIRED. INSTALL NEW AIR HANDLING UNIT PER MANUFACTURER'S INSTRUCTIONS. SEE SECTION VIEW A, SHEET 1M519. INSTALL. NEW SUPPLY AND RETURN DUCT. SEE SECTION VIEW A, SHEET 1M519. ® INSTALL NEW SUPPLY DIFFUSERS AND RETURN REGISTERS. INSTALL NEW RELIEF DAMPER. © INSTALL THERMOSTAT. SEE SHEET M315 FOR CONTROL DIAGRAM. U1 g9J FEg BUILDING 2 -80 EQUIPMENT IN ROOM BELOW CONSTRUCTION AREA IS SENSITIVE TO DUST. PLEASE IAI<L APPROPRIATE PRECAUTIONS. CUSTOMER CONTACT - STEVE MCLAUGHLIN 655 -7770 MECHANICAL MASTER COL 1-8/DA-DE CAUTION!!! All KEY PLAN 0 FEB 0 4 1997 PERMIT CENTER NO SCALE PLANT 2 RECEIVED CITY OF TUKWILA 2.80 -1017 EQU L REF NO DESCRIPTION [DH / � DH 2 2 EACH. I: +DEECO DUCT HEATERS, 8 ° X 8" 1 E 3 0 KW, 208V, 1, 60 Cy 2 STAGE 1 0 5.0 KW, 208V, 1 , 60 Cy. 2 STAGE CONTROLLED AY 2 -STAGE ELECTRIC THERMOSTATS PEN (JOHNSON CONTROLS) MODEL T -25A -1 cH INDEECO DUCT HEATER 12" %12" 4 KW. 2 STAGE, 480 V, 3 PHASE CONTROLLED BY PNEUMATIC THERMOSTAT (JOHNSON CONTOLS MODEL T -4002) _AM © SUPPLY 700 CFM, 24 "X24 ", 15" NECK, 4 - WAY BLOW DIFFUSER SUPPLY 500 CFM, 24 "X24 ", 12" NECK, 4 -WAY BLOW DIFFUSER s RETURN 700 CFM, 18 "X18" REGISTER RETURN 500 CFM, 12 "012" REGISTER - j - RELIEF GRILL - 24 48 LI,ILHAIL AH SEE DWG. 2.80- 1M503, NOMINAL 4700 CFM un DE/7 10 "DIA.,DIFFUSER NOMINAL 275 CFM (TYPICAL 4 THIS DWG., 17 TOTAL). SIMILAR TO TITUS TMRA. 01 SEE DWG. 2.80 -M1M67 0 'OF 2.80 -M1M67 ER:STI EXISTING DUCTED RETURN AIR GRILLE 184"'x36' IRG ID" DIA 500 CFM (TYP-2) 1M17. 111519 KIST. 28.12 1W1n1a 12/12 12012 NECK ADO CO ■ 1 r ��1 5 ,. I 1 4X14 iRE 1' :1011 -IUP 34X114 MANUAL VOL LIME 4608 `46$14 1 26010 I] ',26018 /14016 6I•rj Jlllls2P o ' LIa I'2 X16 300 CFM jf W 50x30 p Dx OOIL 36x24 STEAD COIL 7 ROD 15/26 1036 DX 061E 1 ROW COOLING COIL 18" FLEX 12012 EXIST. 28x12 NEN DUCTED RETURN AIR GRILLE CITE oo �o BY REPLACE A/C UN T J #966178 S. GAVRAS PC STATION A/C J#770270 -01 005 REVISE DUCTWORK,Jj/770173 ADD HEATERS J# 780155 -00 UPGRADE ELECTBUILD UP AREA J1780479 - 18 4. R=S 40/16 240,24 0/A INTAKE APPROVED ORE 1/11/97 4/19/88 9/08/8B 2/16/89 6 -20-89 3 -30 -88 3 -30 -88 3 -30-88 ACCEPTABILITY 1116 DESIGN AND /OR OBTRLE HVAC PLAN SnE UST REPRON 1M JOB NO. 770173 K 1/11/97 cows rvD. 3088 (.OR CGNT IJU. VI OF DUEIWJHF S'EE PARTIAL 'LAN, I M1 1v, r�wr:;r� SY4 11X6588 F INCREASE AIRFLOW Jr710073 G REPAIR WATER LEAKAGE J#710305 -00 H CHANGES IN AC/HEATING 31730007 - 00 - AS - BUILT J FROM HEAT TO OFFICE 10 740051 -CO 32/1 i4 /10—, 7 10/6 c Br 008 MOB MR 5/23/89 12/9/91 6/22/93 12/8/93 7/22/94 PLAN V I NF SCALE: i /8" 1'-o Adic Bv4 arAIW FACILITIES DEPARTMENT O.A REFERENCE DRAWINGS 2.80 -M1D 2.80 -1M519 2.8D -M315 EQUIPMENT SCHEDULES HVAC SECTIONS 6 DETAILS AHU 1DC7 CONTROL DIAGRAM APPROVED LF CEINP OT ROW/ :nERI /IJSTAT CONSTRUCTION NOTES REMOVE EXISTING RETURN GRILL AND ASSOCIATED DUCT. PATCH AND PAINT CEILING TO MATCH EXISTING. COVER ASSOCIATED HOLE ON MEZZANINE AS REQUIRED. INSTALL NEW AIR HANDLING UNIT PER MANUFACTURER'S INSTRUCTIONS. SEE SECTION VIEW A, SHEET 1M519. INSTALL. NEW SUPPLY AND RETURN DUCT. SEE SECTION VIEW A, SHEET 1M519. ® INSTALL NEW SUPPLY DIFFUSERS AND RETURN REGISTERS. INSTALL NEW RELIEF DAMPER. © INSTALL THERMOSTAT. SEE SHEET M315 FOR CONTROL DIAGRAM. U1 g9J FEg BUILDING 2 -80 EQUIPMENT IN ROOM BELOW CONSTRUCTION AREA IS SENSITIVE TO DUST. PLEASE IAI<L APPROPRIATE PRECAUTIONS. CUSTOMER CONTACT - STEVE MCLAUGHLIN 655 -7770 MECHANICAL MASTER COL 1-8/DA-DE CAUTION!!! All KEY PLAN 0 FEB 0 4 1997 PERMIT CENTER NO SCALE PLANT 2 RECEIVED CITY OF TUKWILA 2.80 -1017 EQUIPMENT LIST REF N0. DESCRIPTION 0 STEAMTRAP: STEAMGARD 1/2 SG -B -03 0 STEAMTRAP: STEAMGARD 1 /2 SG -B -07 Q3 STEAMTRAP: STEAMGARD I 4 SG -B -08 ® WESTERN BLOWER TYPE TR, SIZE 4 (24" DIA. DW),71/2 HP 11,400 CFM @ 2" S.P. REF DWG:102 -080- 4063 -441, 2.80 -10315 AKA. 02- 080516- AC- 1M -E01 ® AMERICAN BLOWER SIZE 360 -13 26,000 CFM @ 1 / S.P. 586 RPM, 15 HP REF DWG:102- 080 - 4063 -M1, 2.80 -10314 AKA. 02- 080505- AC- 1M -E03 6 AMERICAN BLOWER HS FAN SIZE 300 3 HP 480V, 3� B.RA, 1750 RPM, 7,000 CFM. REF OWE: 114 -477 SHIT, 2.80 -10505 114 -1111 M1,M2 O CONDENSATE RETURN -M5 STATION 30 GPM @ 40# HD. REF. 102- 080- 4075 ® STEAMTRAP: STEAMGARD 1 /z SG -B -07 ® STEAMTRAP: STEAMGARD 3 / 4 SG -B -08 J' STEAMTRAP: STEAMGARD 3/ SG -B -07 11 STEAMTRAP: STEAMGARD 1 SG -B -09 1Q (2)STEAMTRAP: STEAMGARD 1 /2 SG -B -07 / %7 SEE DWG. NO. 2.80 -0503 NOMINAL 4700 CFM SEE DWG 102 -D80 -4038 MI FOR CONTINUATION SEE DETAIL 12612 HUH 3'Q,4'SW M6! M5' SEE (31W PIP''HG DETAIL 11167 111512 6710502 'U WA UNIT ON MEZ ONE FOR CONT I NUAT a ON HE (DRAWING 2.60 -10 „011 COIL 2801/HR , ° LOPE F —C I' /2 STD j 3 /s SLOT 36x30 ( REHEAT /a C C — COIL - 250 //HR DETAIL S ET ((MM ' 4 SEE DETAIL SEE DETAIL (7 TIFP) 916 SEE DE FOR LEVEL 'SWIT FOR ENLARGED 1067 PLAN VIEW AND EQUIPMENT LIST CONDENSATE TANK FOR PIPING EIMATIIC SEE 102 - 080 1075 -115 05 TIE INTO CRAM 6 CHAS ON MEZZ. AT CAL. A C SEE DWG 2.40 -144505 D 7 FOR TIE -IN. SEE DETAIL 7 /," ST C m 1co CONNECT TO UONDE HSA41E'';UAA) SEE 2.80 4J1M500 FOR CHILLED WATER PIPING THIS AREA. SE 116 HVAC PIPING PLAN SCALE: 1/8 "= 1' -0" 4"C +905 C DETAIL , STU CONVERTORS) 48" CONVECTOR (7 TW) SEE DETAIL 916 BY S.GAPROS APPROVED DATE SSW REV151011 BY S.GAVRAS 1/11/97 F PC STATION 4770270 8 FE' .0 19 FEB87 C 0/107411 109 (ADD COIL) J1270004-03 WDB 16 APR 87 H OOTFALL 109 (ADD DRAIN PAN) J1 270004 -03 NOB 40' 10 - 28 - 87 J SEPERATE TEMP. CONTROLS 4780155 -"00 8Y 4- Pa l APPROVED Q SPe ARG 04P e0 SG B C D REVISION REPLACE A/C UNIT 4966178 ADD CHILLED WATER J,760405 -00 ADD CMCS TANK LEVEL SWITCH 760014 INSTALL NEW CHILLER J #270004 INSTALL NEW STEAM LINES, J#770173 u e4G P�' �OPf� Q P ieP 03 -23-88 CHANGES IN AC /HEATING 4730007 - 00 DATE 4 -19-88 5/19/88 8/30/88 2/16/89 I A, WDB 6/22/95 FACILITIES DEPARTMENT 13 AUBURN. WA. S8002 E3 EVERETT, WA. 98201 LI KEN!, WA. 98031 13 PENTLAND, (1W. 97220 CI RENTCN, WA. 98055 • SEATTLE, WA. 98124 14512 SEE 2.833- 111M2E FOR INTERTIE ROUTING 02 502 CONDENSATE RETURN MAIN BETWEEN MEZZ _ AND SUSPENDED CEILING SEE DETAIL SEE DETA 592 M6 M500 CONSTRUCTION NOTES 1] REMOVE EXISTING 1" PIPING. INSTALL NEW 1" CMS & R LINES. CONNECT TO EXISTING 2 -1/2` LINES. IX>. EXTEND NEW 1" LINES TO NEW AHU 1DC7. INSTALL NEW BOOSTER PUMP, CONTROL VALVES, ETC. SEE DETAIL 10, SHEET 1M512. 4. PROVIDE HIGH POINT AIR VENTS AND LOW POINT DRAINS AS REQUIRED. CONNECT A/C UNIT CONDENSATE DRAIN LINE TO EXISTING 1' DRAIN LINE. ACCEPTABILITY THIS DESIGN AND /DR SPECIFICATION IS APPROVED APPRDVED BY DEPT ATE ATE 31 86 WRG 10/20/86 APPROVED R.GEHRING WDB 10/31/8 APPROVED TITLE TLE 135 LEGEND MECHANICAL MASTER COL. 1- 8 /DA -DE PIPE GUIDE FUH HORIZONTAL UNIT HEATER 70H VERTICAL UNIT HEATER AHU AIR HANDLING UNIT OH UNIT HEATER PUMPED CONDENSATE — c — CONDENSATE - - - -- STEAM OR COND. HIDDEN FROM VIEW FOB FLAT ON BOTTOM FOT FLAT ON TOP GENERAL NOTES I . SLOPE ALL PIPE I / PER 10 "(00 MORE) IN THE DIRECTION SHOWN. 2 MINIMUM PIPE HANGER SPACING: 2" DIA. PIPE AND BELOW @ 10' INTERVALS 2 " -3" DIA. PIPE 0 15' INTERVALS 4 " -6" DIA. PIPE @ 20' INTERVALS 3. INSULATE ALL CHILLED WATER PIPE WITH 1 -1/2" THICK FIBERGLASS INSULATION. WRAP WITH ALUM- INUM JACKET WHERE EXPOSED TO WEATHER. HVAC PIPING PLAN BUILDING 2 -80 REFERENCE DRAWINGS RECEIVED cm oP .uuwlLa B i V'S/ PERMR EERIER 2.80- M1M500(1/4" CHILLED WATER PLAN) 7 i 2.80- 1M512( CHILLER PIPING SCHEMATIC) 2.80 -M1M2E (MASTER CHILLED WATER PIPING PLAN) + 2.80 -M1D (EQUIPMENT SCHEDULES) KEY PLAN NO SCALE SHEET 1M67 1/ 1/97 A OF JOB NO. 760405 1955 DWG. NO. PLT 2 2.80 -1067 WAS 102- 080 - 4001 -M77 iTE1.' LET DESCRIPTION ADJUST I COMMENTS SV -1 7011150N 3 -WAY S V :O:D AN VALVE JOHNSON MODEL VI 1HAA-100 120V /6OHZ 2- POSITION ACTION TC -1 JOHNSON 70HNS01. T- 8000 -3 REVERSE ACTING MODULATING TEMPERATURE CONTROLLER SP. 75 DEG. F (HIGH LIMIT) TC -2 JOHNSON JOHNSON T- 8000 -3 DIRECT ACTING MODULATING TEMPERATURE CONTROLLER S.P. 65 DEG. F (LOW LIMIT) SL -I JOHNSON JOHNSON C- 5230 -3 PNEUMATIC SIGNAL LIMITER LOW LIMIT FOR MINIMUM O.A. 10% DA -1 JOHNSON JOHNSON D- 4073 -1 PNEUMATIC ACTUATOR. 8 -13 PSIG SPRING RANGE FS -I JOHNSON JOHNSON A11A -IC, FREEZE STAT SPST OPEN LOW, MANUAL RESET RANGE 35 -45 DEG F T -I JOHNSON JOHNSON T -4002 -201 SINGLE TEMP HI VOLUME T -STAT, D.V., HOTIZ MOUNT. CV -1 POWERS =10 WM FLOWRITE WAT MIX LVE VA N MODEL 591 -6610 ER 3/4' CN =6, BRONZE BODY & TRIM, CLASS 250 RA DA HIGH LIMIT LOW LIMIT OA B M M ' A IB 9UPPL FAN SIGNAL EWER SETPOINT 75 DEG 000 NC. MIRED AIR 900 CFM l . O AHW fir IDC7 CONTROL SEQUENCE 1. MODES OF OPERATION OCCUPIED- TYPICALLY FIRST SHIFT ROOM TEMPERATURE SET AT ROOM THERMOSTAT FAN- RUN CONTINUOSLY. 2. EQUIPMENT FAN- RUNS CONTINUOUSLY UNLESS MANUALY SHUT OFF BY OCCUPANTS IN ROOM WITH MANUAL START /STOP SWITCH. PUMP - IIJTERLOOKED IN SERIES WITH FAN; RUNS CONTINUOUSLY UNTIL FAN IS SHUT OFF. or UA 100 (CPM CHAR SETPDXIT 40 DEG F IiITERLOCIK TO STOP FAN CHILLED WATER VALVE MODULATED BY ROOM! THERMOSTAT TO MAINTAIN ROOM TEMP @70 F. 0.A.- SYSTEM SHALL MODULATE OUTSIDE AIR TO PROVIDE ECONOMISER COOLING IF POSSIBLE. OUTSIDE AIR THERMOSTAT WILL CLOSE OUTSIDE AIR DAMPER TO MINIMUM (APPROX. 10%) SETTING IF TEMPERATURE EXCEEDS 75 F. MIXED AIR THERMOSTAT WILL MODULATE OUTSIDE AIR DAMPER TO MAINTAIN 65 WHEN OUTSIDE AIR TEMPERATURE IS BELOW 75 F. FREEZE PROTECTION - IF DUCT TEMPERATURE < 40 F, FAN OFF APPROVED CONTROL D tl AGRAM — 1 DC7 SEE EWA'WING 2.80 -1M17 rn1 coo BY APPROVED ROOM TIHERMOSTAII SETPOINT 68 DEG F BOEAMIG FACILITIES DEPARTMENT SA TS F'FSI "' IA6'IIEIALOC'MED WITH FM MERE/ CEM laite> ACCEPTABILITY DESIGN MOAN S ECBFATKH IS APIY1OWV Asmv.IDD PLY DEPT_ DATE S.GAVRAS DECKED 5 GAVRAS PLUMED 1 1/8/97 CONGOS C N a P C L S L J MECHANICAL MASTER COL CONSTRUCTION NOTES 1. INSTALL CONTROLS FOR NEW AHIR HANDLING UNIT AHU -1DC7 COORDINATE WITH ELECTRICAL AS REQUIRED. RED -LINE CHANGES AND RETURN PRINT TO SHAWN GAVRAS 655 -1232. QUESTIONS CALL SHAWN GAVRAS 655 -1232. REFERENCE DRAWINGS 2.80 -1M17 2.80 -1M67 2.80 -M 1 D CONTROL DIAGRAM AHU 1DC7 2 -80 HVAC PLAN HVAC PIPING EQUIPMENT SCHEDULES PLANT 2 RECEIVED cm of TuRwiu 1997 PERMIT CENTER JOB NO DWG NO LAST RERSIO M315 SYMBOL 966178 2.80 -M315 DATE COMP NO EOU I PIvIENT SCHEDULE CC7 4 ROw,12 FPI ,4 PASS,54.O'U61.b- LOB= 58 °F ;LWB= 57°F,0= 377,200;CS =2.50 SHR =. 68:GPM= 75,APD =.66 ;WPD =4.31 PACE#124 CA -61 0054 0 -10 -40/4. FV =487.0 CC2 8 ROW 8 FPI, 8 PASS,30 "X24 " - LDB =55 ° F;LWB= 54 °F;Q= 95,150 ;CS =1.50 PACE #088 -0N- 24.0030.0 -LA -16/8 SHR= .62;GPL1 19;APD =.89 ;WPD =1.45 FV =460.0 CC3 4 R08.12 FP1,4 PASS,60 "030" LDB =57 ° F;LWB= 56 ° F;0 183,600;CS =2.00 PACE #124 -CW- 30.0X60.0 -RA -20/4 SHR= .66;GPM= 37;APD =.50 ;WPD =2.56 FV =408.0 CC4 6 ROW,8 FPI, 6 PASS, 34.5'X24 0" LDB= 57 56 81,770 ;CS =1.50 PACE #086 -CW- 24.0X34.5 -LA -16/6 SHR= .65;GPM=16;APD =.48 ;WPD =1.0 FV= .375.0 CC5 4 ROW,12 FPI,4 PASS,59 "X30'" LDB =59 °F;LWB= 58°F;0= 224,200;CS =2.00 PACE #124 -CW- 30.0059.0 -LA -20/4 SHR= .69;GPA1= 45;APD =.81 ;WPD =3.64 FV =556.0 SEE TWO 2.80- M1M503 DE /7 CV1 CV= 72,3 -WAY MIXING VALVE,2 -1/2 FLANGED ROBERT SHAW #2530 -020 CV2 CV4 CV= 25,N.C.,1 -1/2" NPT ROBERTSHAW #2510 -008 CV3 CV5 CV= 40,N.C.,2" NPT ROBERTSHAW #2510 -024 CHILLER YORK MODEL# LCHAB80, AIR COOLED NOMINAL CAPACITY: 78.5 TON DESIGN CAPACITY: 82.2 TONS @ 901 D.B., 10F RANGE, 451 LVG. WTR. TEMP. PRESSURE DROP: 9.7 FT. H2O @ 192 G.P.M. 100- 69- 31 -15 -0% UNLOADING WITH HOT GAS BYPASS R -22; 460V, 3PH, 60 HP PUMP BEG PUMP #1531- 26C,195 GPM @ 85'HD, TEBC, 7 -1/2 HP,480V 3 PH, 60 HZ, 1750 RPM,2 -0" DISCHARGE ,2- 1 /2 "SUCTION,ACTIVATED BY T- STAT #1 T -STAT #1 PENN MODEL# A19JNC,NEMA 4,SP,DT,30 TO 110 RANGE,SET POINT 60F TURN ON PUMP > 60'F; TURN OFF PUMP < 60'F T -STAT #2 PENN MODEL# A19JNC,NEMA 4,SPDT,30 TO 110 RANGE,SET POINT 35F TURN ON PUMP <35'F; TURN OFF PUMP > 40'F FLOW SWITCH PENN MODEL #F61MB -1, NEMA 4,ACTIVATED BY PUMP INTERTIED WITH CHILLER TO PROVIDE "NO- FLOW" SHUT -OFF. OD;IMI512 DETAIL SCALE NONE PIPING (INSTALLATION FOR MILLED WATER AR 'COPE SYM REVISION A CHANGES IN AC /HEATING J 4730007 -00 B REPLACE A/C UNIT J #966178 PIPING IIIOSEALLATIWN FOR CHILLED WATER AT COIL DETAIL SCALE: NODE #81 PIPING INSTALLATION FCR CHILLED WATER AT COOL DETAIL SCALE: NOME (TYP CC2.004) / 5 (TYP 0C3,005) PIPING INSTALLATION FOR CHILLED WATER AT COIL DETAIL o , SCALE: NONE M1M- 12 (TYP CCI) THIS DRAWING HAS BEEN RELEVELED TO THE 1988 LEVEL LIST (A)(M) 2 MIM-50a1,512 MIDP 510 BY P S� GAVRAS APPROVED GAVRAS 2 II DATE 1/12/97 SEM mq� -ooao REVISION DRAWN BY W.BOLL IG B.CLADNEY ENGINEERED BY BOLL IG CHECKED 2.PETRAM 4/7/87 BY APPROVED ATE STRAINER /D / % /LEG FACILITIES DEPARTMENT APS CS Fv LDB LIB FPO GPM FLEX CONNECTION (TYP) PIPING, SCHEMATIC DETAIL SCALE: 1011E 17 AUBURN, WA. 98002 E3 EVERETT, WA_ 98201 E3 KENT, WA, 98031 D P128TLAND, 0R. 97220 E3 RENTON, WA. 98055 • SEATTLE, WA. 98124 LEGE% 'AUGER PHES'SURE IIFOP7TT H2D) AIR PRESSURE URCPIItt1 H20) .GDNNELTI'.ON 5171) III ) 861BLE I-EAT RATIO TOTAL I-EAT TRANSFER(BTUH) COIN_ FACE VELDCITY(FF81) LEAVIING DRY BULR(D£SIIGN BASIS) LEAVIING ✓MET BULB(DESIGN BASIS) FINS PER MIEN GALLON PER AAIINIRDE 12 AUTO ▪ AIR VENT (TYP) - --1V MOMETER (TYP -1/2 MPT) FLOW SWITCH GLOBE VALVE RESSURE GUAGE (TYP -1/2" MPT) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY EPT )ATE DATE 0 -28 -87 10 -28 -87 W.R. EBBING 10 -28 -87 APPROVED D SUBTITLE TITLE GENERAL NOTES COOLING COILS WERE SIZED FOR THE FOLLOWING INLET CONDITIONS. 80 °F ENT. DB 68 ° F ENT. 1' 50% R) CONSTRUCTION NOTES 1. INSTALL CHWS & R PIPING FOR NEW COOLING COIL. INCLUDE BOOSTER PUMP, VALVES, STRAINER, AIR VENTS TEMPERATURE GAUGES AND PRESSURE GAUGES. 2. ROUTE PIPING AS REQUIRED; PROVIDE AIR VENTS AND LOW POINT DRAINS AS REQUIRED. QUESTIONS, CALL SHAWN GAVRAS 655 -1232 REFERENCE DRAWINGS 2.80 -1M67 (CHILLER LOCATION -1/8" PLAN VIEW) 2.80- M1M500 (1/4" PLAN, EQUIPMENT ROOM) 2.80 -1M67 HVAC PIPING PLAN RECENEC cm oP Tulcwlu 2.80M1D EQUIPMENT SCHEDULES FEB 041997 CHILLED WATER -EAST SYSTEM BUILDING 2 -80 MECHANICAL MASTER PLT 2 PERMIT CENTER B LAST REVISION (SYM SHEET_ 270004 DWG. ND. 2.80 -18512 1/12/97 DATE OF 1727 SYM A 1J2 .' REVISION REPLACE A/C UNIT 4966178 2 -1/2" OWDSRW LIGHT FIXTURE (TYP) DETAIL SCALE NONE 1/16/9 2' PC 1 -1/2" C /, I I 10 "DiA FLEX 14 "DNA 10 "X18 m 00ao BY GAVRAS 8 ABANDONED 6'" STEAM 6"' STEAM 12' "x11" TO 10'00A TWA 18 "x36 APPROVED D GAVRAS — rIISIHn1L SYs1im, LA-HOAR AIDED C .,20 REALASEHOETIT PEEiERS REb1 - 1S1 STAGE PuE',1. I/451' - SIDE STAGE REPEL 111112 E111011, ROOF PENETRATION EXIIS1.. 1116 "'x12" 1/ PDC dt_ APPROX. 10' TO MEZZ. DECK ST 1 915 1 9 TRANSIT 6 "x6" WOOD SLEEPERS (TYP -2) 18 "xI8 RETURN GRILL- 18 ".56` RETURN GRILL SECTION SCALE 3/8 SiON 16 10 10' DIA TRANSIIION 1 X10" DIA 19117 s 11/519 TO" DIA SUPPLY DIFFUSERS (TYP -2) Y APPROVED DATE EXIST 4` PIPE MED PIPE IJEZZAHINE DEKIE IIE�I,1 0 FACILITIES DEPARTMENT L7 AUBURN, WA. 98002 a EV'ERETT, WA. 98201 a KENT, WA. 98031 ❑ PORTLAND, D.R_ 97220 RENTON, WA, 98455 • SEATTLE, WA_ 98124 ACCEPTABILITY THIS DESIGN AND /0 SPECIFICATION IS APPROVED APPROVED BR DEPT. DATE DRAWN BY S MCGRATH GENERAL NOTES FAN AND FILTER ACCESS. KEEP AREA ABOVE UNIT CLEAR. 2. FABRICATE ALL RESTANGUALAR DUCT AND SQUARE -TO -ROUND TRANSIST IONS. 3 FIELD VERIFY ALL MEASUREMENTS PRIOR TO CONSTRUCTION. 4 SUPPORT DUCT FROM MEZZ DECK OR ROOF JOISTS AS REQUIRED. 5. ALL WORK SHALL CONFORM 10 SMACNA STANDARDS AND APPLICABLE CODES, DALE SUBTITLE CONSTRUCTION NOTES INSTALL PACE AIR HANDLING UNIT. MOUNT UNIT ON (2) 6X6 SLEEPERS AND LAG TO MEZZANINE DECK AS REQUIRED. INSTALL AND INSULATE SUPPLY DUCT. a> INSTALL SUPPLY DIFFUSERS IN EXISTING CEILING PENETRATIONS. CONNECT SUPPLY DIFFUSERS TO NEW SUPPLY DUCT WITH 10" DIA FLEX DUCT. 14 INSTALL NEW RETURN AIR DUCT. INSTALL RETURN AIR GRILLS. FABRICATE ASSOCIATED RECTANGULAR DUCT. © INSTALL OUTSIDE AIR DUCT. CONNECT NEW OUTSIDE AIR DUCT TO EXISTING DUCT THROUGH ROOF, REMOVE EXISTING RECTANGULAR OFFSET PRIOR TO INSTALLING NEW DUCT. ® CHECK ROOF PENETRATION AND EXISTING WEATHER CAP FOR LEAKS. REPAIR OR REPLACE AS REQUIRED. TITLE MECHANICAL MASTER SECTIONS & DETAILS BUILDING 2 -80 LAST SHEET RECEIVED GIN OF TIKWILA 79O41997 PERMIT CENTER A ' /17/97 EVISION SI YM 1M519 JOB NO. 939048 - 01 DATE OEI'"G COM ERCIAL AIRP A 2 -84 2 -117 2 -116 APPROVED YM VICINITY MAP PLANT 2 Mop GATE 0 -18 SITE ACCESS 2 -55 0 I I O i t � I DA BOE /iYG FACIUTI£S DEPARTMENT BUILDING CODE NOTES CONSTRUCTION OCOIGPANCE S£ISMii; ZONE 3 mgi-oo ENTIRE BUILDING IS SPRINKLERED TOTAL BUILDING3EA = 128.904 SF PROJECT AREA = 4C0 SF STRUCTURAL NOTE'S: TYPE V, N 0-2, OFFICE AND LIMN MANUFACTURING 3 DESIGN AND WOMMVANSNIP PER IBC 1991 ROOF LIVE LOAD (SNEAI) = 25 psf 118111D : 80 nph FLIP. B SEISMIC DESIGN : Fp = ZI Cp Ep Z = 0.3 (ZONE 3) I = 1,0 Cp = (2) 0.75 = 1.5 Wp -au OF LEOH. EQUIPMENT STRUCTURAL STEEL Fy = 36 ksi TIMER I1 BI OR BETTER BUILDING: 2.;i0 MECHANICAL ACCEPTABILITY 1115 DESIGN MOD /OR SFECI ICA1Htli S APPROVED APPROVED BY DATE SHEET NO 2.80 -1M17 2.80 -1M67 2.80 -9315 2.80 -IM5i2 2.80-1M519 DRAWN BY N. HUJTO IIIELY(EU taro APPROVED 1 1E 11/5/93 L'_GAL DESCRIPTION AFN• OOR J -0020, A TF:A:1T OF LAND BETWEEN THE OIAYAI.SH WATERWAY AS ESTABLISHED BY COl6IERCIJi- WATERWAY DISTRICT k I OF KING COUNTY, WASHING - MN & E. MARGINAL WAY, IN SECTIONS 28, 29.. & 33, TOWNSHIP 24 N, RANGE 4 EAST, W.M., DESCRIBES IN, KROLL BOOK PAGE 79. TRACT CONTAINS AN AREA I- APPROX 2,897,955 SO FEET. SITE .ASO ESS. 8123 EAST MARGINAL WAY SOUTH I,GE ARCA MASTER DRAWING INDEX ITLE H'✓AC PLAT! F.VAC PIPING PLAN CONTROL DIAGRAM SECTIONS & DETAILS SECTIONS S I)F1AIl I understand that the Plan Check eporo°olv are e t '1 1 adopted code or .... �d,.on ,ra nYof?r g Date �/y \- Permit No _L=-Ig1 ""'— SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL 'ELECTRICAL ❑ PLUMBING ❑ GAS PIPING CITY OF TUKWILA C ....DING DIVISION COVER SHEET 2.80 BUILDING COL oup REVISION REV. K REV. L NEW REV. B REV. A PLANT 2 /14 0 TOK AP PR0 3IE O Ft 7 1990 RECEVeD cm oP ,ulcwltA FEB 0 4 1997 PERMIT CENTER DWG NO ING DIVISION LAST REVISION SHEET Al aoD No. 430007 -60 AOL 2.80-Al DA DF COMP O.