Loading...
HomeMy WebLinkAboutPermit M97-0046 - CONTRACTORS LABOR POOLCity of Tukwila < - Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 * Tukwila, Washington 98188 MECHANICAL PERMIT Permit. No: M97 -0046 Type: B -MECH Category: NRES Address: 13028 INTERURBAN AV S Location: Parcel #: 000480 -0017 Contractor License No: EVERGI *20107 UMC Edition: 1994 • Signature: Print Name: HtC A'iLL. C._ t- Date: Valuation: Total Permit Fee: Title: Cm " 2 (206) 431-3670 Status: ISSUED Issued: 04/18/1997 Expires: 10 /15/1997 TENANT CONTRACTORS LABOR POOL 13028 INTERURBAN AVENUE S, SUITE 112, TUKWILA, WA OWNER TIME DC INC 3470 MT DIABLO BL #A -100, LAFAYETTE CA CONTRACTOR EVERGREEN REFRIGERATION 727 S KENYON ST, ,SEATTLE, 'WA'98108:. CONTACT MIKE LEAHY.:. 727 S KENYON, .SEATTLE ;WA 98108 **************** * * * ** * ** * * * * * * * * * * * * * * * * * * * *, * * * * * ** * * * ** * * * * * * *** * * * * ** *** Permit Description: NSTALL ONE HVAC ROOFTOP UNIT AND TWO CEILING EXHAUST;: FANS, AND. DUCTWORK; AND CONTROLS. Phone: 206 763 -1744 Phone: 206 763 -1744 1 000.00 70.94 ******************:*******..**************.** x* *. * * * * * * * * * * * * * * * * *' * * * * * * * * * * * ** Permit :Center`Authorized Signature :Date' I hereby:`.certffy that I have read and .examined this permit and' know the same to be true.and correct..All prov,isions law governing this work will be complied'.with, whether speci and -ordinances.. herein or not. The granting of this permit does not presume .to'give authority to.violate .or cancel the provisions • any other state:or local laws regulating construction. or t e •-rfo =nce of work. I am authorized to sign for and obtain this, bypi p iny ,•ermi This permit shall become.nu.11 and void if the .,work ;is not commenced within 180 days from the date of assuance.,,or if :the.work is suspended or abandoned for a period of 180 daysfrom the inspection. tr>t'u:: +:lirir. ix� •� :: 4'v.YYSw14i:luA Yaw+ +mrr.«cww..•+¢ Addr.es: 13.06 INTERURBAN AV au T•t.e.• Tenants' .CONTRACTORS LABOR POOL Permit No: M97 -0046 Permit 'Condi t • 'No 'changes wi 11 be made to the plans unless approved by Architect o.r ;Engi and the Tukwi,l2. Building Division. All, permits inspection ,recar ds, a*i eppr.oved ;plans shall available' at the job (:s,i`te =prior, to t „o.f any con:- str�uction Thee d °;arse to•,.:be mainta:inedand .avail - able. Anti 1. final ,i`nspect:ion "ap is granted .. Al i constr'uctl,on to in,,confor:mance With approved plans and r erq'u i r eme'nts..of the. Up i f orni Bu 1 1 d 'hg : Code `.(1994 Edition) a �'amende'`dt' Uniform Machani'ca1 Edition), and Wastitoii Sta.te Energy Code (1994 Edition) Val idi,ty,,of Perm i t. • , - The i s4uanc;e r :. of a permit or:. approval.of plans; :'spe,cificat and .'computa,t.i,.ons srha1l 'pot', be : can str-ued to a permitfo.r�,° or an approval of, an_y vi,o•lation..- of ' any of'” the prov i s ions of "the: bu i i d i no code or :of ""any'' other' }` ordlnance.'' of the;._,�urisd otion.:. No permit presuming to; g ,r authority to vlolate. or cancel the provisions •of this code, l''1''b l i d> :: 5'. ':MA4t#ACTURERS'�` INSTALLATION. INS'TRUCTIONS:. "REQUIRED ON ± ;,SIrT FOR THE BUILCaNC INSPECTORS ;REVIEW ..:..:' • a 6: Ele :; peril% ts:; shad l be .,o bta tined th W rough the a4h i ngton ,� S t e Diy o n i of' .,"abort aii4, `Indu. ies' and all `e lectrical' ` w o;•�w r i 1 1' > �,incpected .;bv that`',agency C 4� 4`8 - 6x630) . '�t Status: ISUED. Type: B-MECH App Applied 04/00/1997 Parcel. #: 0004.80 --0017 Issued: 04/18/1997. * kkk****** * * *•k *•k * * * * **** * * *k **•k* k*` k* k*** A**** * * * *k**k * *k*** *k **k **kkk *k ** Project Name/Tenant: / c�r,+r•c,c 1 "001 .a - or s Labor Description of work to be done: , � t t ((e. e:''\`' Z I.L r I ,2 .� .a \ l of Constructio n e l7 Site Address: (le-, •oy BLfX S 130 Z91 1n.‘`eror boom /\a. City State /Zip: S , -• ': Tax Parcel Number: O ') 1 Fro - Coo /4 Phone: Property Owner: Street Address: � _ City State /Zip: Fax #: City /State /Zip: Contact Person: 0 Water 0 Sewer 0 Metro Phone: Street Address: ' City State /Zip: Fax #: Contractor: .-• w Vt" r , F�. >,-, r, ,.r,1 r. 1,... Phone: - 7 � Fax #: /y/ ' 1 7 � ' 1 t' ( 1 Street Address: 1 \ , City State /Zip: Architect: Phone: Street Address: City State/Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS;PERMITREVIEW AND APPROVAL REQUESTED: O -BE FILLED<OUTBY'APPLICANT)' Description of work to be done: , � t t ((e. e:''\`' Z I.L r I ,2 .� .a \ l .I Will there be storage of flammable /combustible hazardous material In the building? ❑ yes ❑ no Attach list of materials and st orag e location on se ap rate 81/2 X 11 aver indicating quantities & Material Safety Data Sheets Above Ground Tanks U Antennas /Satellite Dishes 3 ulkhead/Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence 1NI7 Mechanical ❑ Manufactured Housing- Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application APPLICANTREQUEST.FOR MISCELLANEOUS PUBLIC :WORKS PERMITS? ❑ Channelizatlon /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ❑ Water Meter /Permanent ft ❑ Water Meter Temp # ❑ Miscellaneous WATER METER DEPOSIT /REFUND BILLING: Name: Address: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. Thy ciyill be reviewed and Is subject to possible revision by the Permit Center to comply with current fee schedulesClTY OF TUKWILA Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the da AapRlippt' o all expire by limitation. The building official may extend the time for action by the applicant for a period &If gxcUethn a : • days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. PERMIT CENTER D a a application accepted: / / -17e.. F /e/1;2 MISCPMT.DOC 7/11/96 ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill_ _ cubic yards 0 sq. ft.grading/clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: ❑ Moving Oversized Load/Hauling Date application expires: Permit: Number: Project: gal Schedule: Phone: City /State /Zip: Application taken by) (initials) BUILDING OWNERS AUTHORIZED AGENT; SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks / Water Tanks Supported dirbctij upon grade exceeding 5,000 gallons and a ratio of height to diameter or width . which exceeds 2 :1 Signature: !---- ._,-- %' --- - Date'vn- : , ,; Commercial Tenant Improvement Permit Print name: • "" (; .,r 7 T ' <.; ,,�., Phone: /6 ). / 7 ir �,� Fax #: ,r_ r J r, ,) a Address: -' ` - ~T Fences - Over 6 feetin °Height 4 ` ❑ City /gtate /Z ! `� ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks / Water Tanks Supported dirbctij upon grade exceeding 5,000 gallons and a ratio of height to diameter or width . which exceeds 2 :1 PERMIT REVIEW Submit checklist : No: M -9 ❑ Antennas /Satellite Dishes Submit checklist ' No: M -1 ❑ Awnings/Canopies - No signage Commercial Tenant Improvement Permit ❑ Bulkhead /Dock Submit checklist No M -10 ❑ Commercial:Reroof ' Submit checklist No M - 6 ❑ Demolition:: Submit checklist No M -3;,. M =3a ❑ Fences - Over 6 feetin °Height Submit checklist No: M -9 ❑ Land Altering/Grading/Preloads Submit checklist No: M -2 ❑ Loading:Docks Commercial Tenant Improvement Permit. Subrnit checklist No:-H-17 in Mechanical (Residential & Commercial) Submit checklist : No M -8, Residential only. -. H -6, H -16 ❑ MiscellaneousiPublic Works Permits Submit checklist No H -9 ❑ Manufactured Housing•(RED INSIGNIA ONLY) Submit checklist . No M -5 ❑ Moving Oversized'Load /Hauling Submit checklist No M -5 ❑ Parking Lots Submit checklist No: M -4 ❑ � __ to ❑ Residential Reroof - Exempt with following exception: If roof structure be repaired or replaced Residential Building Permit Submit checklist No: M -6 Retaining Walls;- Over 4 feet in height Submit checklist No M -1 ❑ Temporary Facilities Submit checklist No: M -7 ❑ Teinporary'Pedestrian Protection/Exit Systems.:: ,. Submit checklist No: M -4 ❑ Tree Cutting Submit checklist : No M -2 ALL MISCELLANEOUS P - SIT APPLICATIONS MUST BE SUB ' ED WITH THE FOLLOWING: ALL DRAWINGS SHAL BE AT A LEGIBLE SCALE AND NEATLYDRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED > ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter, from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 . ✓ -\ Working Drawings Floor plan \ System layout N. Elevations (for roof mounted equipment) and proposed screening N. Heat Loss Calculations \ Roof plan required to identify individual equipment and the location of each installation (Uniform Mechanical Code 504(e)) H.V.A.C. over 2,000 CFM (approximately 5 ton and larger) must be provided with smoke detection s hut -off and will be routed to the Fire Prevention division for additional comments, code section Uniform Mechanical code 1009. Provide 2 sets of manufacturer's installation instructions ✓ Document Requirements Documentation or specifications must be provided to show that replacement equipment complies with the efficiency ratings and other applicable requirements of the Washington State Nonresidential Energy Code. \ Structural engineer's analysis is required to replace existing roof equipment weighing 400 pounds and greater (Uniform Mechanical Code Section 2336(a)) \ \ Water heaters and vents are included in the UMC - please include any water heaters or vents being installed or replaced. \ s', Structural calculations stamped by a Washington State licensed Structural Engineer shall be required if structural work is to be done \ • Number of units Provide 2 sets of manufacturer's installation instructions ✓ Working Drawings On 8 1/2 x 11 sheet of paper include the following: , Narrative of work to be done (i.e., changeout, replace existing equipment, modifications, etc.) • Type of unit being installed Rating /Size \ • Number of units Provide 2 sets of manufacturer's installation instructions Note: Water heaters and vents are included in the Uniform Mechanical Code - please include any water heaters or vents being installed or replaced 2/97 CITY OF TUKWILA Permit Centek 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 MECHANICAL PERMIT !I i M -8 Submittal Checklist Miscellaneous Permits COMMERCIAL.: Four complete sets of drawings and attachments required with application submittal RESIDENTIAL: Four complete sets of drawings and attachments required with application submittal rrri' Cooa PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER m 0046 DATE %if ; PROJECT NAME co'%ACt., DEPARTMENT: BUILDING DIVISION FIRE PREVENTION PLANNING MS El ► b Wq� w Y� u DI �� ON . i : LIC VV ORi STRUCTURAL Li PERMIT COORDINATOR DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE Et NOT COMPLETE COMMENTS TUES /THURS ROUTING: PLEASE ROUTE E NO FURTHER REVIEW REQUIRED E ROUTED BY STAFF (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED U REVIEWERS INITIAL C:ROUTE -F DATE DUE DATE lit 1p sq� NOT APPLICABLE El I DUE DATE i{ APPROVED fl APPROVED W/ CONDITIONS . NOT APPROVED (attach comments) E DATE APPROVED W/ CONDITIONS rj NOT APPROVED (attach comments) Q DATE DUE DATE (Cerdficadon of occupancy required, — ) /i) 1 �� dr r of inspectia mkL AU S Date called Special instructions: Date wanted: 6 _2.1_7 ,1 p.m. Requester: 0A14 1 �N ., U --1( Phone No.: j 1 �� {t j, I • INSPECTION O. CITY. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: INSPECTION RECORD Retain a copy with permit Approved per applicable codes. I Inspector Date: 1-0 PERMIT NO. 206) 431 -3670 Corrections required prior to approval. /. a1 1L. [ 1 $42.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • j.ct ` • cgs r -Aboe- PDOir Type of inspection: � A' � d • I rr( IZBAA t/ S Date called: Li _ i S - 9.1 Date wanted: ' ( a r "1 2 � ' 1I p.m. Special instructions: Requester: Dm H ersekm ,3 Phone No.I> o . 3 - ) i 4 COMMENTS: r eceipt No.: INSPECTION RECORD 1, Retain a copy with permit Mr C C>4 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: :I . 1lr4 .! A, Addres "" ype of inspe• D - te cello.. Date wanted: '•n: (� ' U ., '- �a rr� Special Instructions: Requester: Phone No.: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 pproved per applicable codes. COMMENTS:. Inspector: fra 1 I Corrections required prior to approval. Date: G Ar $42.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: Project C / (�!/�'I /i'21�,1�/l„ L/.f �? /600 Type of inspection: / •. ..... .f_ Date called: / Addres .?" / 424 r Specia Instructions: Date wanted: 9-2.--/ y7 � �.rr i Requester: Phone No.: INSPEC' •N NO, CITY OF TUKWILA BUILDING DIVISION 6300 , Southcenter Blvd., #100, Tukwila, WA 98188 TAO Approved per applicable codes. COMMENTS: Inspector: Receipt No.: INSPECTION RECORD Retain a copy with permit Date: (206) 431 -3670 Corrections required prior to approval. Date: y [-] $42.00 R NSPECTIO FEE REQUIRED. Prior to Inspection, fee' must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. *A' *k * * *•k* l *** *;A ** k/ r * AA j ***• k*.** ( A : da*kk•k**— k * **,* **. **,** *** * **kk,�l• ITV OF 1UKt4ILA..:WA k* ( / ) * d• �1. **•l��/r *4F•f: * *,4 * * TRANSMIT * *•k*A *•k '* k* ****•A.i+k* *k * *'* * * * *A *A* *kill •TRANSMXT Numbar . .R97O0 /0 Ainoun't: 70.94 04/16/97-09111 Pavmerit ':Me thoc a. CHECK 110tattaro EVERGREEN REFR,I0 Ire it., SLB . Permit Na: M9 ?- •00.46 Tvpen B-•MECH MECHANICAL PERMIT. .. Pcir el No; 0.00450 001.7 Site . Address:: 1302E3 XNTCI LIRBAN AV 5 Total Fees: 70.44 This Payment ?0,94 Tatal. ALL Pmts: 70.94 BalLnde: .00 **** ,* * * **** * * * ** *42 * * *0k A k * * *' * * * *k ***- k*A* * *** * *A *** * *k * *k* Aoeount Code 000/345.83Q,. 000/322..100 ..Description PLAN. CHECK - Np,HR MECHANICAL - - NpNUES Amount 14.19 ProjectInfo Project Address Contractors L.P., 13028 Interurban Ave. 3. #112 Date 4/8/97 Capacity Btu/h Tukwila, Washington. For Building Dept. Use tiql.e0111LP SEER or EER IPLV Applicant Name: tivergreen Refrigeration Inc. Applicant Address: 727 S. iceggon St., aeattie, WA sales. Applicant Phone: 206 763 1744 Caolin E • ui • ment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location PGP1 LLNNOX OCS -16- 653 -75 58500 1950 1950 8.90 58000 Roof 0.125" 0.5A C.V. Ceiling Void 272 BROM S90 93 0.125" 0.5A C.V, Ceiling Void Fan E ui ment Schedule Equip. ID Brand Name' Equip. ID Brand Name' Total CFM Model No. CFM Output Btuh SP' HP/BHP Flow Control Location of Service sr1 MOAN S90 75000 58000 93 0.125" 0.5A C.V. Ceiling Void 272 BROM S90 93 0.125" 0.5A C.V, Ceiling Void Heath': E' ui . ment Schedule Equip. ID Brand Name' Model No.' Capacity Btulh Total CFM OSA ctm or Econo? Input Btuh Output Btuh Efficiency' 901.1 LERROX GCS -16- 659 -75 58000 1950 1950 75000 58000 0.784 !).f '4. . ri�.A.Ii = `..,. ....:: i ='� •S�r V �Y Z "• ...... _. _.. ifr P. i ^):+ Y,C+ .,. .1.tY S�. �tf, �. .+:.. Y.+ .. 1.. ,...i l.7.nx `f«t =�.. r.. .'�5'.7.A.r .. a..v i'... v. ,: ,�.... 1. ����':t • ,. s .+f•r :':)�: i;l.. i�t4J�t v.'�� .i V.: 1�� ,_`7.�5'" ;iV; ,. y.�tt.. . +.���1��;:4•. r�'�. t 5.4. ��.�:. .4�� )I'4.. �. r... �•.�:,rcy. .�'s „ '"1' • 1994 Wir 'ngton State Nonresidential Energy Code Corr:.` rnce Form Mechanical Summary 'MECH -SUM 1894 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Compliance Option Equipment Schedules Installation 1 rooftop IIVRC unit, 2 ixhaust tans and the associated ductwork and controls. ® Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) The following information is required to be Incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill In the required Information below. June, 1995 1 1f available. 2 As tested according to Table 14-1,14-2 or 143. 3 1f required. ' COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 6 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description ion of Simple System qualifications, it Heating/Cooling or Cooling Only: ng IY ® Constant vol? E] Spilt system? ® Air cooled? 0'.4 Packaged sys? • <54,000 t3tuh or 1900 cfm? � Economizer Included? If Heating Only: jr <5000 cfm? • <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Heating Only Start System Type eatin Cooling or Cooling Only <5000 cfm? yes no <70% OA yes na Complex Systems 1994 W 'ngton State Nonresidential Energy Code Con ■nce Form Use this flowchart to determine If project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( Reference Sec. 1421 no Econo included? no yes 54,000 Btuh r 1900 cfm yes Y Reference Sec. 1423 Reference Sec. 1420 Simple System Il Allowed <414,000 Btu or 1900 cfm yes Use Complex System Refer to MECH -COMP Mechanical Complex Systems for assistance In determining which Complex Systems requirements are applicable to this project. Mechanical Plans Checklist MECH -CHK 1994 Washington State Energy Code Compliance Forms June, 1995 Project Address Contractors L.P., 13028 Interurban Ave. 8. #112 (Date 4/8/97 necessary to check a mechanical permit application for compliance with the mechanical requirements in the Energy Code. The following information is Washington State Nonresidential Applicability (yes, no, n.a.) Code Section C ponent Information Required Location on Plans Building Department Notes HVAC REQUIREMEN • 1401-1424) 1411 Equipment performanc yea 1411.4 Pkg. elec. htg,& clg. List heat pumps on schedule Mi yea 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M1 1412 HVAC controls yea 1412.1 Temperature zones Indicate locations on plans M1 yea 1412.2 Deadband control Indicate 5 degree deadband minimum Mi n• a 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 dill. day types Mi yes 1412.4.1 Dampers Indicate damper location and automatic controls Indicate microprocessor on thermostat schedule Mi n.a. 1412.5 Heat pump control n.a. 1412.6 Combustion htg. Indicate modulating or staged control yea 1412.7 Balancing Indicate balancing features on plans Mi n.a. 1422 Thermostat Interlock Indicate thermostat Interlock on plans yea 1423 Economizers Equipment schedule Mi 1413 Air economizers yes 1413.1 Operation Indicate 100% capability on schedule Mi yes 1413.2 Control Indicate controls able to evaluate outside air Mi yes 1413.3 Integrated operation Indicate capability for partial cooling M• 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary Mi yes 1414.2 Duct Insulation Indicate R -value of Insulation on duct Mi n. a. 1415.1 Piping insulation Indicate R -value of insulation on piping .a. 1424 Separate air sys. Indicate separate systems on plans yes Mech. Sum. Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 Insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1450 Heated pools 1452 Pool water heaters Indicate not electric resistance 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover • 1994 WO' . •ngton State Nonresidential Energy Code Corr ' .nce Form no Is circled for any question, provide explanation: • • 1994 ‘M',1 'ngton State Nonresidential Energy Code Con-' ' nce Form Mechanical - General Requirements 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a doadband of at least 5 degrees F within which the suppy of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where doadband controls are not appropriate. 2, Buildings complying With Section 1141.4, if In the proposed building energy analysis, heating and cooling thermostat setpoints aro sot to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped With a moans for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: FIVAC systems shall bo equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature sotpoint. 2. Equipment with full load demands of 2 kW (6,828 Btu/h) or less may be controlled by readily accessible manual off- hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers Mich close atdomaticaly when the system is off or upon power failure. Stair shaft and etovator shaft smoke relief openings shall be equipped with normally open dampers, These dampers shall remain closed In normal operation until activated by the fire alarm system or other approved smoke detection system Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set-up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall Indicate when supplemeral heating is being used through visual means (e.g., LED indicators). 1412.8 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btulh shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a moans for balancing, including but not limited to, darrpors, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall bo of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. Mechanical Permit Plans Checklist 1994 Washington State Energy Code Compliance Forms MECH -CHK June, 1895 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial coding even when additional mechanical cooling Is required to meet the remainder of the cooling load. Controls shall not precludetho economizer operation when mechanical cooling is required simukaneousy. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu/h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be scaled in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 Inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. 1414.2 Insulation: Duds and plenums that are constructed as part of the building envelope shall meet the requirements of Chapter 13. Other ducts and plenums shall be thermally insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14.6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51.26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: a. Alr coded, constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. b. Air cooled, constant volume split systems, which provide heating, cooing or both, with cooling capacity of 54,000 Btu /h or less. c. Heating only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements in Section 1412, Mere separate heating and cooling equipment serve, the same temperature zone, thermostats shall be interlocked to prevent simukaneous heating and cooling, 1423 Economizers: Economizers meeting the requirements of Section 1413 shall be installed on packaged roof top fan - cooling units having a supply capacity of greater than 1,800 cfm or a total cooling capacity greater than 54,000 Btu/h. The total capacity of all units without economizers shall not exceed 240,000 Btu/h por building. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. 4- DETACH TO DISPLAY CERTIFICATE ".11"141":;;. , DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A , • • "A. ' • • t • 44 . 7 ' r., hA., t , • • :0 ". LIA 98100 r5Atelt47 ....................................... - • • , STATE OF WASHINGTON F625.052.000 (3.971 .4,44 EXHAUST FAN SCHEDULE GAS PACKAGE EQUIPMENT SCHEDULE MANE. /MODEL ARK MANE. MODEL TONS. REMAIIK EF -1 < 2 COOLING HEATING ELECTRICAL 5A WEIGHT CFM SP MIN. OSA TOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE ILC.A. UNIT ECON OSA DPR 1'41 TOTAL LW 6D1 BTUH STUN STUN ( %) (V) (A) L88 L08 LOS rm. I LEMiO% 655 IF69Y]S 5 R50 03 1 940 565C0 10.0 C.9 0000 WOO 159 I 9'0 I 30 I 0 530 26 — EXHAUST FAN SCHEDULE MARK MANE. /MODEL CFM SP HP /AMP POWER REMAIIK EF -1 < 2 BROAN - 540 W 0705 5A 6V /I0 0513 18/0 O DROP 70/0 10' DROP 5 TON ON ROOF EF -1 & 2 9'0 00 L4 TO 0000 VENT 16'0 100 19'0 HVAC PLAN SCALE : 1/8' - 1-0' DUCTWORK u ALL PICT OLHVlONS IXJ IKAN ARE CLEAR MOP PLIGMON , ADD 7' TO EACH DIMEN51o01 To OBTAIN OUTSIDE DIMENSION ADD 410 EACH DIMENSION IF DUCTWORKS IS ON THE EXTERIOR OF BUILDING. THE FIRST NUMBER ON ALL MKT OMEN51001515 THE WIDTH AND THE SECOND NUMBER 15 THE HEIGHT. 13 MATERIAL-5 WITHIN OULT5 OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER UM4 1999, 500.401.7. IS I/O SEA INCHES AND 2 DUCTWORK 011IGH O IS 0051fiNED STATIC PRESSURE A BETWEEN PRREESSURES ABOVE I/O INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -IO. IS ALL DUCT GAUGES PER TABLE 6 -A OF 1999 MAL 16 ALL 0000 SUPPORTS PER TABLE G -E 00 1014 UM .7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID C PER LODES. 14 BALANGJG PAMPERS ARE To RE NSTALLIL ON ALL 000157H COOTS OR 750650X5 DUCT INSULATION 21 INSULATE OR LINE DUCTWORK PER WASHINGTON STATE ENERGY 0 MECHANICAL LODES. GENERAL CONTRACTOR 31 GENERAL CONTRACTOR TO PROVIDE AND COT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR. AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND EIRE PROOF LNLN6 000 0.046. WRH ERI BEFORE ACT OR TG TO VERIFY PE NETRATION LOCATION AND DIMENSIONS GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 29 G EN E RAL C ON TR ACT OR 10 PWOI V E ADEQUATE STRUCTURAL SUFPORT AS 35 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 36 GENERAL CONTRACTOR TO PROVIDE SERVILE ACCESS PER LODE TO ALL MECHANICAL EQUIPMENT. 47 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERI, PROVIDE ALL CANT STRIPS ANO CURB INSULATION, AND SEAL AGAINST LEAKS 5G GENERAL O FOR TO 000V075 ALL GUTTING AND PATCHN6 OF T -BAR CEILING ELECTRICAL 4.1 ERI TO INSTALL ALL LOW VOLTAGE CONTROL WIRING. CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 9.9 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT 51105, I -0405 AND LOCATIONS WITH ERI MECHANICAL PLAN AND WITH FIELD CONDNIONS 99 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WIG LIGHT SWITCH ERI TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 9F 004004NO. 96 001 TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. PLUMBING 5I PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EOUIPMENT.PER CODE. 5Z PLUMBING CONTRACTOR OPFSET VENTS 10 FEET MINIMUM FROM ALL 1-1440 FRESH 41R INTAKES OR 7' ABOVE HIGHEST POINT OF INTAKE. 53 CONDENSATE BRAINS AND BRAIN 12'05 BY ERI., GRAIN TO ROOF WITHIN IT OF UNITS. ENERGY CINIF OOMPLIANOE 61 AT A MIMMUM, EACH FLOOR 15 TO BE CONSIDERED A SEPER4TE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 62 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, IMO RELIEF OUTLETS SERVING CONDITIONED WALES SHALL BE 0011I900 WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM 15 OFF OR UPON POWER FAILURE, PER W5EC 504.191291. 63 AIR ECONOMISERS WHERE REQUIRED BY 6007 ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMISER SHALL COMPLY WITH WSEL SEC, 1927. FILE COPY Go PIG CI..7 and missions c-.e : . not auualr mo .w.von a..,.7 plans 1 code of •I- - Eom000I00. / Y M I 07 .9 s Data -I ha-J- ODL � SEPARATE PERMIT REQUIRED FOR: aMECHANICAL ELECTRICAL ❑ PLUMBING INCAS PIPING CITY OF TUKWILA GJILDING DIVISION cm BF ti% cm WR10001114 APR 11 81997 P030ITC po CPR 1 6057 REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT 09:05 APPROVAL OF TUKWILA BUILDING OM- "^ 0 / Q / w / t om / bC u_ CC Z w M w CC w w X 0 0 00 NO A 1- G 2. Y. • p O N O O F T O I- 0 0, S a 6 0 6 MOOD DATE - 97 DRAWING DATE DWG. BY CHK. BY: JOB NO DWG. FILE: REVISIONS CONTRACT.00D 1 F O 0 N • O 2 6 ; N o a OF F 0 ITE GEN RE LL ML 4 f 0 CONTRACTORS LABOR POOL HVAC PLAN - NOT FOR CONSTRUCTION 727 SOUTH KENYON