Loading...
HomeMy WebLinkAboutPermit M97-0126 - SOUTHCENTER CORPORATE SQUARE - BUILDING 9r-1-* 2/..0 City of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: Type: Category: Address: 665 ANDOVER PK W Location: BUILDING #9 Parcel #: 262304 -9075 Contractor License No: COMFOP *064D2 TENANT OWNER CONTRACTOR CONTACT *****************************************;******** il• * *, * * *• ***. * **k * * *k * * * ** * * ** Permit Description: REMOVE: "''AND REPLACE 50 TON VAV, UNIT ON ROOF UMC Edition: 1994 M97 -0126 B -MECH NRES SOUTHCENTER CORPORATE SQUARE 665 ANDOVER PK W, TUKWILA, WA 98188 SOUTHCENTER CORPORATE SQUARE C/O JSH PROPERTIES INC, 1005 ANDOVER COMFORT PLUS P.O. BOX 913,. ,KENT,, .,WA 98035 GERALD WARE 6617 SOUTH 193RD PLACE,:, KENT, WA 98032 Permit ;Center Authorized Signature. Valuation: Total Permit Fee: *******I i***4**i i:************.**************** * * * * * * * * * ** * * * * * * *k ** * * * * * * * ** Date (206) 431 -3670 Status: ISSUED Issued: 09/05/1997 Expires: 03 /04/1998 Phone:. (206)575 -8500 PARK E, TUKWILA WA 98188 Phone: 206 251 -9840 Phone: 425 - 251 -9840 50,000.00 42.81 I hereby certify that I have read and examined this permit and know the same to be true, and correct. All provisions of law and ordinances: governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I an) authorized to sign for and obtain this building permit. Signature:: �`�4�r -a.. Date: Name: G=4E",zNI\-20. Title: Q_' k,.% This permit shall become null and..void if.the work.s not commenced within 180 days from the date �.i .of s.suance, or -if ,i if the.. work , is suspended or abandoned, for a period of 1`80 =days from.the.:last' inspection. Project Name/Tenant: Description of work to be done: t 4-- @L n T b !y ' l R t I= Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Nue of Construction: o - s-toorrage — 1 Above Ground Tanks Di Antennas /Satellite Dishes Bulkhead/Docks Commercial Reroof Site Addre s: ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection/Exit Systems ! W �" City State/Zip: 't "tom � Kwk 1 ,R Tax Par. Mlu�t�§r :Lt_ q �.- 1, �� Property Owner: -tit Phone: Street Address: City State/Zip: Fax #: Contact Person: G- R1R-kD V■fl -RE Phone: l'-' — 1 -X84'0 Street Address: 66 1 Sty'. L a_ City State/Zip: VE)-st °�QQ Fax #: '-i- �_ �� t - �l s > t Contractor: ' Phone: S reet Address: ---S 6, \ s o _ e1-, . City State/Zip: \d,S'I T Qtzt,�1, Fax #: Phone: —. _,� Architect: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOU PERMIT• REVIEW,AND'APPROVAL ( TO' BEFILLED :OUTBY: ;. Description of work to be done: t 4-- @L n T b !y ' l R t I= Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and location on se arate 8 1/2 X 11 a er Indicatin uantities & Material Safet Data Sheets - s-toorrage — 1 Above Ground Tanks Di Antennas /Satellite Dishes Bulkhead/Docks Commercial Reroof ❑ Demolition El Fence ® Mechanical ❑ Manufactured Housing- Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection/Exit Systems ❑ Temporary Facilities ❑ Tree Cutting CITY OF T' IKWILA Permit Center c ; 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. `'' AP, PL •ICANtREQUESTFOR:MISCELLANEDUS RUBLICVORKS PERMITS =' : <'l '.' ❑ Channelization/Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # Size(s): Cl Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s 1: Est. quantity: gal Schedule: ❑ Miscellaneous DI Moving Oversized Load/Hauling MONTHLY SERVICE BILLINGS TO: Name: Address: Name: Address: 0 Water WATER METER DEPOSIT/REFUND BILLING: Date application accepted: MISCPMT.DOC 7/11/96 ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s)• ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 _ sq. ft.grading/clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only 0 Sewer q)-- Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within,180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application expires: FOR STAFF USE ONLY ,Project'Nuinby, s; Phone: I City /State /Zip: 0 Metro Phone: City /State /Zip: 0 Standby ■■•• I Applications ing (initials) BUILDING OWNER OR AUTHORIZED AGENT: Signature: I Date: g - - 0 Print name: �k 4Z 1r•.\ '∎2 E C� 1� t� Phone: SI- ° 184�a I r} -0.82 °l g0l1 Address: r' • \ a-' '? N. - • ity /State /Zip: l, Es1 7 ■6- _ ALL MISCELLANEOUS P - ' IT APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: > ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ' Above;Ground Tanks/Water;: Tanks: Supported ,diractly upon grade exceeding 5,000 gallons and ratio of height to diameter or width '. . which exceeds 2 :t • SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW LoadingDocksi:::: : Mechanicat (Hesidentiat & :Comtiiercial):.. El Miscellaneous Public1Warks-Permits Manufactured Housing=(REDlNSlGNIA ONLY Moving_Oversized;Load/Hauling ci Parking Lots Commerciai:Tenant Improvement Permit .:::... Submit. checklist . No: M -10 < . ubmitchecklist<±,. No: M =6. '.Submit checklist; No: M-2 Submit checklist No: M -4 Residential Building. Permit Submit checklist No: M -6' ,Submit checklist ` No :: M -1 Submit checklist ; No: M -4 Residential' Reroof :Exempt with following exception:: If; roof ;structure: to 'be,repaired. :or.replaced RetainingWalls' »: Over 4 feet in height ■ Temporary. Facilities, • Te mporaniP edes trian Protec System Tree Cutting. Commercial Tenant`.Improvement Permit:,'' Submit checklist No:: H -17 Submit checklist:. NO: M?$; Residential H -16 Submit'checklist : No: Ka Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other thanthe owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from property owner authorizing the agent to submit this permit application and obtain the permit will be required a. partof this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 $ qQ.s( READY FOR ISSUANCE BALANCE DUE YES NO TATE CONTRACTORS LICENSE IS THIS CONTRACTOR IN THE SYSTEM? IRED? NO APPLICANT CONTACTED DATE CALLED CALLED BY CITY OF TUICWILA Address: 665 ANDOVER Plw .W `: Su.i:te Tenant :•SOLITHCENTER CORPORATE SQUARE S ISSUED Type ::6. - MECH . Applied 08/29/1997 .. Parcel it 2623(04 -9075 Is3ued 09/05/1997 * * * * *, ** 4t k****'** *11 * *** *k * ** * - k***k*4•kk ** * :k•k * * * *lcic *k *4 *** *•k• *** #*** *. Perm i•t No: Permit Conditions: 71 • No changes - wall be made to the plans unless approved by the or Engineer: and'. the,.Tukwt10,,Building Division. All' permits, inspection r ec rirds, a a'p plans shall be available at the job sit prior to the' any co-; struction These ,doc lme • n t < s are to,be maintained .,and avai l- able until tina'l ii spection is gr All construction to be :done 'in confor ?manc w ith approved. ..plans and requirements, cif the Uniform Building Code , (.1.994 Edition)",,;,a`s ` amended,:• Uniform Mechariica,l Ed'iti,on),. and Wast i tigton State Energy Code (1994 Ed i Validity of `Permit., The issuanc'e:,of a permit or^ plans cat tons, and- ;'c.omputa,tions sha11''not' be con= str ued/sto be a permit for', qr an approval of, any violation of any. of °-'the provisio of `the... bu i 1 d i ng code or ,of any' otheror of thejurisd:iction. No permit presuming t g i v ' e • .author.i ty° to violate . �or.`.cance..i. the p r o v i s i o n s -of ,00s code sha 1`i" be va 1 I d 5. MANUFACTURERS INSTALLATION INSTRUCTIONS „REQUIRED ON FORTHE BUILDING , I.NS , PECTORS.';REVIEW Pliimbing''`�'p'ermi.es shall 7. We, obtained `• ..thro;ugh, the Seattl County Dear t;.ment of Publ Hea th Plumbing will be insp that agency,, j'ncludirlg ail gas piping (2W472.) 4722) . E 1 6 0 0 0 1 ,;<`per,mits shall be obtained through':,the Washington .Statrr; Di Labor and Indiustr.i'es ..and al I electrical wor10. ri!,i 11 b,e,,,in spec ted by that agency ; (244-6630) Read it,ly accessible access to roof mounted equipment i require ACTIVITY NUMBER M97 -0126 PROJECT NAME DEPARTMENT: BUILD G DIVISION -a-q �LIC WORq KS L. DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 9/02/97 COMPLETE COMMENTS TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED E ROUTED BY STAFF (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F Penn*C�r4n Copy PLAN REVIEW / ROUTING SLIP CORRECTION DETERMINATION: APPROVED n APPROVED W/ CONDITIONS SOUTRCENTER CORPORATE SQUARE BUILDING 19 FIRE PREVENTION E PLANING DMSIC STRUCTURAL �_ PERMIT CO R DINA T OR • NL NOT COMPLETE E NOT APPLICABLE Ei DATE APPROVALS OR CORRECTIONS: (ten days) APPROVED 11 APPROVED W/ CONDITIONS I I DATE DATE DATE DUE DATE (Certification of occupancy requited, 8/29/97 DUEDATE 9/16/97 NOT APPROVED (attach comments) [-1 NOT APPROVED (attach comments) • Project c/ t t doY Q 1 i,aNt, Type of insp Ion: . v ,. ‘ ,. �j Date called: mil, I l) — ( - �l7 A dress: � lP �J l,..a ' -,- Special instructions: Date wanted: )O' 2' 91 p.m. Requester: n Phone No.: ?/c ! r + r 0 INSPECT I • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit • r � I 31 -3670 Corrections required prior to approval. r 0 1 7 '149 PERMIT NO. Date: /0_ [i $42.0 T REINSPECTI • FEE REQUIR D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd, Suite 100. Call to schedule reinspection. Receipt No.: Date: Projeck - C Type of inspectio� Address °' Date called: Special instructio s: Date wanted: p.m. 74 ' 1 7 Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspecto INSPECTION RECORD Retain a copy with permit Date: �.'., (206) 431 -3670 Corrections required prior to approval. 7 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. k*k **k * */t *'. * **'k. * * ** .*4 0****** r k ***:* * *k * ** * * *A *A. * * ** * * *k * ** *•k **** 'ITY :OF'- 1'UKWtLH, WA TTRANSMIT * k ;A .k *** * * * * * *h* *k *. * *tY�X***h *k kNekl n irc>t *k *.*k***11****A* *k* ** , 1'RANSM.IT. Number: ,R970063q Am;ot rt. 42..81 09/05/97 14.41 • Payment: Me;thod,: CHECK Natation:. COMFORT .PLUS Init. 8LR Account Code 000/3 451.830. 000/322.100 Permit No M97 -0126 Type: B -MCCH MECHANICAL PERMIT Parcel' No. 262304-9075 Site Address: 6G5 ANDOVER PI: W Location: BUILDING U9 Total Fees: 42.81 This Payment 42.81. Total ALL Pmts. 42.81 Balance: .00 ******************• A* * * * * *1A * * * *** * * * * * * * * * * * * *k•A* k * * *A h * * **A *•k * ** Description PLAN CHECK - NONRES MECHANICAL 1010NRES t.. 't ..t.. T" .'- i� %r�t•pr..i.... Amount 8.56 3.9.23 • '• '-0' A 1G5;1'+tiIgrWt telUiY;4V41 7;0.14Ab C City of Tukwila Fire Department 7Jl f 4: Fire Department Review Control # C(-7,.0 Re: H.V.A.C. at ,t-i-(ICp> ( co( p. 5CUc ?( - 4 9 Dear Sir': X65 Pndwer KU) John W Rants, Mayor Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at greater than 2,000 cfm require auto- shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 2. Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) 3. In areas that are not continuously occupied, automatic smoke detection shall be provided at each control unit(s) location to provide notification of fire at that location. (NFPA 1 -5.6) The installation of wiring and equipment shall be in !tSSAG ?A t6 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 375.4439 4:1 City of Tukwila Fire Department Page number 2 accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1- 5.5.4) 4. When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) 5. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd John W Rants, Mayor Thomas P. Keefe, Fire Chief ,Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 DEPARTMENT OF LABORS AND INDUSTRIES ('H CgRT,iFE TH THE PERSON NA MED HEREON IS REGISTERED AS PROVIDED BY LAW AS A yY ' +F % 't `i ^. ♦ IS � I,rS � .,1 .. �. ' � • � ' � es. _; ;.Y �i ,• A t y v - ,1 a l',..*',,,, « y � � �-. vri,r t"-t... : , � x 't }'rt:d:� )jrt�:; v : :. . [ . il • .t . �-,y^ , §' 1 J r 1 ■ . 1 :.� s v e . 7''.f'r Rr�, r;' %' .v F,,l t k�n : -y.L �'' K ! ` ' fr i ', • ,;:• �.•i . t om •1` :.. .•F `C,�., ;r' . o... ..: 1tir`.0 y �. - r ^ ;•:; r , E _ • t i t . tl+ fi �t:'?;�:3�+��'• °`; f'', = 0",ti�,r: ,l �ry.. `x.7 `' °' '' • �� 1 lo c: . • , . r fi ry : . ;7 .. '/,` )r...- - ' 1211 :- i tria4 S C•`a, •y .. ' �..(...I t 'ur ;,•T••+� 71$Y;17- 1t� r �� S � ts�f '3' ,q • f.( t.._, -•i 0 ' - 1 _ � • :� W t��� '�'�i •a rev ^i ,v ei 1 � �. . :�V..Sz � - •, Li.. L.. - �1 +._ ..ff +": .Y;'.. %t••J"4 ;;, ' rFJv J:•',r ')...,Y.• .:e l , '�;C�. { 4: �` h � ;u . " - ..v { - 4.b.: 1 4 ` ,z,' d �'' � T °° `a � iTy ',.A. ' Ir k •t ..4"' '' : .V.?7'r' +Y a !_ DETACH TO DISPLAY CERTIFICATE-1 , STATE OF WASHINGTON F825•352. 000(3.92) RECEIVED CITY OF TUKWILA AUG 2 1997 PERMIT CENTER Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Sirature FINALAPP.FRM City of Tukwila Fire Department TUKWILA FIRS DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued 7t 31 z T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief �I V/i 1,)N 7 L � Permit No. f 9 7 / I Project Name r' NS L) A-t2 E Address (, 4. f I'i} Suite # D2/' Headquarters Station: 444 Andover Pad* East • Tukwila, Washington 98188 1 • Phone: (206) 575 -4404 • Fax (206) 5754439 t Fll_E COPY understand that the Plan Check approvals are subject to errors and omissions and approval of I. plans does not authorize the violation of any r,t.ir;pted code or ordinance. lans acknowledged. ►r actor's copy of approved p By Date 1 Permit No. SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ELECTRICAL ❑ PLUMBING 'GAS PIPING CITY OF TUKWILA BUILDING DIVISION CITY OF TUKWILA APPROVED SEP LI1997 BUll DING DIVISION �' 9 TOTAL DEVELOPMENT SITE' AREA: 772.7110 sr !MONO ARCA: 74t1,0/0 ST NRA PARKING IOIAI.: 1..147 SIALLS >Uj 1M L k j r ' ' - 1 !-- r H uill """ 1 1 011 g111111111111111111111 OffilliIIIIIIIIIIIIIIIg L _ littiti ufficitititititiii gliffitiliffillulittl. = _ = _ -- = — — i .r i_ jillo Hilliiii -_,-.. _ 01111.111.111.110 '.._, 0.IIII-11.1.11110 — = 1 --7. Lnath.wwwn : I = _-- _ = 11111111111111111111r1 11111111E AttOONER WEST ••• I MTTIM 1 1 77 - : . irrnmi \01.1_ 0 Nagl 0:AtION Or DOORS ASO NOT ARIT.ED 7, INT oRMATION APPROmMAIE MAO SOUIHCENKR CORPORAIE SQUARE 1111111. SECOND FLOOR FIRST FLOOR • HUILOIMO 9 SOIIAIit rt.th lo.7o0 Sr MA 31014113: 2 0 no 0 (:?[] rat�i aCl 20* v. IOCAV'OM Or DOORS Alin ...'HeO. s %OI UI1.IitU ?. WrORMA1104 APPROM.I /ATE U) 40' w U 2 •a SOU NICEN EE R CORPORATE SQUARE stoma. AA r...... D...1. 4a. 1` M eves% i�ii�. OC 1 Ei 11111 BUILDING 9 - I /�tii 9. 17 INSTRUCTIONS READ BEFORE INSTALLING RETRO —MATE Q. • NEW ROOFTOP UNIT RETRO— MATE EXISTING SUPPORT ROOF CURB V CHANNEL Q (F) 1. SHUT OFF AND DISCONNECT ALL GAS AND ELECTRICAL CONNECTIONS TO THE EXISTING ROOFTOP UNIT. 2. REMOVE EXISTING UNIT BEING. CAREFUL NOT TO DAMAGE THE ROOFCURB OR THE EXISTING DUCT WORK. 3. REMOVE ALL GASKETING FROM EXISTING ROOFCURB AND DUCT WORK AND REPLACE WITH NEW GASKETING SUPPLIED WITH RETRO -MATE. GASKET ENTIRE ROOFCURB PERIMETER AND SUPPLY /RETURN PERIMETERS WITH 1 1/2" x 1/4" ADHESIVE BACKED GASKET. IF DUCT SUPPORT CHANNELS ARE NOT FLUSH WITH THE TOP OF THE CURB, USE 3/4" x 1" GASKET ON THOSE CHANNELS. 4. IF SEPARATE SUPPORT CHANNELS ARE INCLUDED WITH RETRO-MATE, HANG THESE CHANNELS ON THE EXISTING ROOFCURB EXACTLY WHERE INDICATED ON DRAWING SUPPLIED WITH RETRO -MATE AND FASTEN IN PLACE. THESE CHANNELS ARE USUALLY USED TO SUPPORT THE END OF THE NEW ROOFTOP UNIT FROM BELOW THE RETRO -MATE. 5. CAREFULLY SET RETRO -MATE ON EXISTING ROOFCURB BEING SURE THAT DUCT TRANSITIONS LINE UP WITH EXISTING DUCT WORK AND THE RETRO -MATE IS NOT SET BACKWARD. STANDING SEAM 6. SECURE RETRO -MATE TO EXISTING CURB, SPACING APPROPRIATE (IF STANDING S) FASTENERS A MINIMUM OF 12" O.C. THROUGH RETRO -MATE COUNTER CAULK IN FIELD._.. . FLASHING. 7. GASKET ENTIRE RETRO -MATE PERIMETER AND SUPPLY /RETURN PERIMETERS WITH 1 1/2" x 1/4" ADHESIVE BACKED GASKET. IF RETRO-MATE CHANNELS ARE NOT FLUSH WITH THE TOP OF THE CURB, USE 3/4" x 1" GASKET ON THOSE CHANNELS. 8. HOIST THE NEW ROOFTOP UNIT UP TO THE ROOF AND GENTLY PLACE ON THE RETRO -MATE BEING SURE THAT DUCT TRANSITIONS LINE UP AND THE NEW UNIT IS NOT SET BACKWARD (SUPPLY MATES WITH SUPPLY ETC..). 9. SECURE NEW ROOFTOP UNIT TO RETRO -MATE PER UNIT MANUFACTURER'S INSTALLATION INSTRUCTIONS. 10. CONNECT ALL ELECTRICAL AND GAS LINES TO NEW ROOFTOP UNIT PER MANUFACTURER'S RECOMMENDED INSTRUCTIONS. 11. MAINTAIN YOUR RETRO -MATE ADAPTER BY PAINTING THE WELDED AREAS ONCE A YEAR TO AVOID RUST. ThyC cc 0 2 0 WC }, F1'LVi,in r .n:..•In 4 rer •grsree, >1 August 27, 1997 Mr. Gerald Ware COMFORT PLUS 6617 So. 193rd Place Kent, WA. 98032 RICHARD HUDSON & ASSOCIATES, INC. CONSULTING ENGINEERS 1605 12TH. AVENUE • SUITE 18 SEATTLE, WASHINGTON 98122 206- 324 -6160 FAX 324 -6248 Re: Southcenter Corporate Square Andover Park West Tukwila, WA. 98188 Rick Hudson, P.E. Chuck Morris, P.E. Dear Mr. Ware, At your request, I visited the above referenced site on Wednesday, April 27, 1997, to review the roof framing for additional loads to be added due to replacement of the existing roof top mechanical units. The existing mechanics], heating and cooling units will be replaced with newer units on buildings numbered 5, 6, 7, 8, and 9. The Southoenter Corporate Square contains 12 separate buildings constructed similarly. As you explained, buildings numbered 1. through 4 were constructed early in 1980, with the remaining building built during the following 4 year interval. The architectural plans and structural plans that you have supplied for our use were drawn at two different time periods. The architectural drawings were drawn for the first set of buildings. and the structural drawings were drawn for the latter set of buildings. The structural roof framing plan indicates a Berkeley roof framing system with 5 -1 /8 "x 25 -1/2" glu-lams at 16' on center (oc), with 4x14 doug -fir purlins at 8 foot on center and 2x4 doug -fir subpurlins at 16" on center at the roof top units. The framing changes at one corner of the buildings where bearing walls are used in lieu of the glu -lam beams. At this area 2x10's at 12" on center are used to frame the roof and provide support for the roof top units. The roof top units are located so that part of it is supported on the 2x10's and part is supported on the purlins. RECEIVED CITY OF TUKWILA PERMIT CENTER OOSSFi GNU NOSQ(lH T 0: E T 2.6i LZ Cf u 1 recorded the beam sizes and spacings for Buildings numbered 5 and 6. Buildings 7, 8, and 9 appear to have similar layouts for. the framing and roof to unit orientation. At buildings • 5 and 6, I removed additional ceiling tile and pulled back the insulation to expose the existing framing below the roof top units. The existing framing appears to differ from the plans in the spacing • of the purlins. The purlin spacing varies from apptr'oximately 2' -6" to 5 0f on center instead of the 8 foot on center • called out on the structural drawings. The 2x10s were not visible due to the insulation at the roof and wall framing extending to the roof sheathing. Although the purlin spacing and roof top unit locations vary from building to building, the loading and support condition are being considered similarly for the analysis. Generally, there are (3) -- 4x14 purlins, (2) 4x12 purlins, and 2x10 @'•12" oc (assumed per plan call out) providing support for the ',new roof top unit loads. A review of the structural notes indicates that the framing ].umber called out is Douglas Fir - Larch No. 1.' Based on the above framing condition, the purlins have been reviewed for structural adequacy. It is our opinion that the new roof top units can be installed with out providing additional framing at these areas. If you have any additional questions, please call. Sincerely yours, Richard Hudson and Associates , //G� e William J. W ke P. . p Y. Z'd OOSSti CINti NOSQnH Ze :ZT na Marketing Guide asArrwrican Standard Inc. 1997 e Miff Library Product Litereture Product Section Unita Product Rootio • Air Conditionin Model 000 Literature Tyoe Marketing Guide S equence 24 Date Februe 1997 File No. Supersedes New Ordering No. R 1-MG-24 EER MARKETING GUIDE The purpose of this marketing guide is to provide a reference to the capacity and efficiencies of large rooftop products from 27 1/2.60 tons. The ratings are determined at ARI 360 conditions. Definition of Terms: MBh -- 1000 BTU per hour or 1000 BTUH. EER -- Energy efficiency ratio. A ratio calculated by dividing the net cooling capacity in MBh by the total power input in kw at any given set of rating conditions expressed in STUN per watt. System Kw -- All power going to unit. (Compressors, fans, motors, controls.) IPLV •- Integrated part load value. A single number part load efficiency figure of merit calculated. ARI 360 •- A standard established for testing, rating, specification and performance requirements. ARI 360 conditions — At full load 80/67 evap 96 amb, part load at 80/67 evap 80 amb. RECEIVED CITY OF TUKWILA PERMIT CENTER TC *330A40C TE'330A40C YC *330A40C TC'360A40C TE *360A40C YC *360A40C TC *4 TE *420A40C TC'480A40C TE *480A40C YC *480A40C TC'600A40C TE "600A40C , 27.5 50 TON VOYAGER 111 THROWAWAY FILTERS, NO INLET GUIDE VANES, NO ECONOMIZER BEST CASE CATALOG PERFORMANCE DATA MODEL # NET TOTAL EER IPLV MEH KW 316 31.57 314 31.73 314 31.8 342.0 36.1 342.0 36.3 9.4 12 342.0 36.4 9.4 11.9 396 41.15 9.6 394 41.48 9.5 YC`420A40C 394 41.62 9.5 11.9 454 50.75 9.0 9.3 452 454 544 542 51.19 50.87 63.07 63.74 10.0 12.2 9.9 12 9.9 11.9 9.5 12,2 8.8 8.9 8.6 8.5 2 12.3 12 9.2 9.3 8.8 8.6 Equipment Type & Rating Air Conditlohers and Heat Pump Cooling Ratings Packaged Term. Air Conditioners do Heat Pumps Cooling Ratings Heat Pump Heating Ratings Packaged Team. Beat Pumps Heatin Rat' Warm Air Furnaces & Combination FurnacalA.C. Warm -Air Duct Furnaces and Unit Heaters 3• a�. ..� ...ice.. I S`VUi.i'■-■ N'..,. II0 TABLE 14-1 Standard Rating Conditions and Minimum Performance for Air Cooled Unitary Air Conditioners, Heat Pumps, Packaged Terminal Air Conditioners, Warm Air Furnaces, Dud Furnaces and Unit Heaters '65,000 red £,135,000 AU Unitary Barth 8.9 EER >135,003 and <760,000 Btu/I3 Coolie : C ;� ' • Air Co ditiane s Heat Punt 11.5 8.5 EER . r . {. • 10.0 SEER 9.7 SEER 7.5 IPLV 7.5 IPLV 12.2 - (020 x Cap /1000 ER 82 °F 6.8 HSPF 6.6 HSPF NA NA NA NA <65,000 Btu/ Coolin > 60,000 Bw/ti Conlin MI Capacities 465,000 Btu/h CoolilgCapacity >65,000 and <135,000 Btu/h Cooling Capacity > 135,000 Btu/b Coolin All Capacities <225,000 Btu/h 2,225,000 Btu/h 2:,225,000 Btu/h All Size Gas Duct Furnaces Category ac All Size GaS Unit Heaters MI Size Oil Unit Heaters AI R Sab eategoay & Ratan= Cessations Split Systems Sin le Pack Atr assns Heat Mr Conditional and Heat Pumps Stand ow Tamp: Split Systems Single Packaae All Unitary Standard Ratings: Standard Ratin s: Heat Pumps Standard Ratio : Gas and Oil Fired Seasonal Ratings: Max Rated Capac Min Rated Steady State Seasonal or Part Load NA NA 8.2 EER 8.7 EER 10.0 - (0.16 x Cap /1000) EER 95 °F 3.0 COP 110% El 47 °F db /43°F wb 80% l4 Gas, Max Ratin Gas, Min Ratin 78% 4 Oil, Max 81% E Oil Min Ratite ' 81% E, Mu Rated Capac 78% Et4 Min Rated • - • 75% Max Rated Capaci 78% F Min Rated 74% 4 2.9 COP 2.0 COP 47 °F 17 °F 9 • (0.026x Cap/ 1000) 6ER 47°F db /43 °F wb 78% AFUg NA NA NA NA 81% 81% Melbnnm Ratans: Et '4 4 1994 FIRST EDITION 2.0 COP 17 °F db /15 °F wb Standard ARI 210/240- 1989 AR1310 -1990 ARI 210/240- 1989 ARI 365 -1986 ARI 380.1990 DOE IOCFR Part430 AAgN ANSI 221.47- 1983 UL 727.1986 ANSI 283.9- 1986 ANSI 283.8- 1985 UL 731 -1988 For units that have a heating section, deduct 0.2 from all required EER's and IPLV's. Par multi-capacity equipment the minimum performance shall apply to each step provided Multi- capacity refers to manufacturer published rating for more than one capacity mode allowed by the product's controls. Capacity (Cap) means the rated cooling capacity of the product in Btu/h in accordance with the cited ARI standard. If the unit's capacity is less than, 7,000 Atu/h, uses 7,000 Btu/h in the calculation, If the unit's capacity is greater than 15,000 Atu/h, use 15,000 Btu/h in the calculation. These values apply to non-NAECA equipment. See referenced standard for definition of Thermal efficiency (Et), (100% - flue losses). To be consistent with National Appliance Energy Conservation Act ( NAECA) of 1987 (Public Law 100- 12). These values apply to furnace and combination units covered by NAECA. Minimum and maximum ratings as provided for and allnw«t hat the ,.�:•� ^� ----�. IAl • Table 27 -1 - 27.5.50 Ton Electrical Service Sizing Data Electrical Data Notes: 1. All customer wiring and devices must be installed in accordance with local and national electrical codes. Table 27.2 - 27.5 50 Ton Electrical Service Sizing Data Electric Heat Module (Electric Heat • its Only) Notes: 1. All FLA in this table are based on he operating at 208, 240, 480, and 600 volts. 27 Fan Motors Supply Compressor Standard/HI- Efficiency Condenser Exhaust Allowable Electrical Voltage RLA LRA FLA FLA Model Characteristics Range No/Ton (Ea.) (Ea.) HP FLA No. HP (Ea.) HP EI a.) TC/TE/YC•330 208/60/3 187. 229 2/10,15 41.9/62.8 213/323 7.5 24.8/21.4 3 1.1 7.0 1.0 6.7 10.0 30.6/28.8 230/60/3 207 -253 41.9/62.8 247/376 7.5 21.6/18.6 7.0 6.7 10.0 26.6/25.0 460/60/3 414-506 18.1/27.3 95/142 7.5 10.8/9.3 3.5 3.1 10.0 13.3/12.5 575/60/3 617 -633 14.6/21.8 76/114 7.5 8,6/7.5 2.8 2.9 10.0 10.6/10.0 TC/TE/YC•360 208/60/3 187 - 229 2/15 62.8 323 7.5 24.8/21.4 3 1.1 7.0 1.0 6.7 10.0 30.6/28.8 230/60/3 207-253 62.8 376 7.5 21.6/18.6 7.0 6.7 10.0 26.6/25.0 460/60/3 414-506 27.3 142 7.5 10.8/9.3 3.5 3.1 10.0 13.3/12.5 575/60/3 517 -633 21.8 114 7.5 8.6/7.5 2.8 2.9 10.0 10.6/10.0 TC/TE/YC•420 208/60/3 187-229 2/15 62.8 323 7.5 24.8/21.4 3 1.1 7,0 1.0 6.7 10.0 30.6/28.8 15.0 44.9f39.8 230/60/3 207-253 62.8 376 7.5 21.6/18.6 7.0 6.7 10.0 26.625.0 15.0 40.0/34.6 460/60/3 414506 27.3 142 7.5 10.8/9.3 3.5 3.1 10.0 13.3/12.5 15.0 20.0/17.3 575/60/3 517-633 21.8 114 7.5 8.6/7.5 2.8 2.9 10.0 10.6/10.0 15.0 15.6/13.8 TC/TE/YC•480 208/60/3 187-229 3/15,15,10 62.8/62.8/41.9 323/323/213 10.0 30.6/28.8 4 1.1 7,0 1.0 6.7 15.0 44.9/39.8 230/60/3 207-253 62,8/62.8/41.9 376/376/247 10,0 26.6/25.0 7.0 6.7 15.0 40.0/34,6 460/60/3 414506 27.3/27.3/18.1 142/142/95 10.0 13.3/12.5 3,5 3.1 16.0 20.0/17.3 575/60/3 517-633 21.821.8/14.6 114/114/76 10.0 10.6/10.0 2.8 2.9 15.0 15.6/13.8 TUT E/raa 208/60/3 187 - 229 3/15 62.8 323 10.0 30.628.8 4 1.1 7.0 1.0 6.7 15.0 44.9/39.8 20.0 58.0/53.0 230/60/ 3 207-253 62.8 376 10.0 26.6/25.0 7.0 6.7 15.0 40.0/34.6 20.0 51.0/46.0 •-�j 2 460/60/3 414-506 27.3 142 10.0 13.3/12.5 3,5 3.1 / 15.0 20.0/17.3 .ZQ,Q, x.5/23. 575/60/3 511.633 21.8 114 10.0 10.6/10.0 2.8 2.9 15.0 15.6/13.8 20.0 20.5/18.4 Models: TED/TEH 330 thru 600 Electric Heat FLA Nominal Nominal Unit Size Unit KW Heater (Tons) Voltage 36 72 90 108 208 74.9 1 .4 - - - 27.5, 30.0, 35.0 230 86.6 29.9 - - - 460 43.3 : •.0 86.6 108.3 - 575 34.6 5 . r 69.3 86.6 - 208 - 112. • - - - 40.0, 50.0 230 - 129.9 - - - 460 - 65.0 86.6 108.3 129.9 575 62,0 69.3 86.6 103,9 1'4 7 b N r h / nb 'h• I s r N... ' • Ot'' va -704 31 --53Mo Dimensional Data Figure 33-1 — 40 -50 Tons (TC, TE, YC Low & High Heat) 54 % 7A 35 75 1'As 3 Places See Roofcurb Drawing For Details On Field Duct Fitup and Connections REAR VIEW SHOWING DUCT OPENINGS FOR HORIZONTAL UNIT NOTE 1. ALL DIMENSIONS INCHES. 2. THRU•BASE ELECTRICAL LOCATIONS ARE ONLY PRESENT WHEN OPTION IS ORDERED. 21831' TOP VIEW SHOWING DUCT OPENINGS IN BASE FOR DOWNFLOW CONFIGURATION 49314 11'4 33 90% 3" NPS Connection (ThnrBase Electrical) 2% 2% 75 M•I •I 10 .(t 80 Ms 3% II 2% 3 Places 1 A" NPS Connection IThru -Base Electrical) 232'354 voM :'w tI 90'A, 77 General Data Table 12-1 — General Data — 50 -Ton 12 50 Ton Cooling Performance' Nominal Gross Capacity J / 587,000 Natural Gas Heat Low High Heating Input (BTUH) 300,000 600,000 Second Stage 400,000 800,000 Heating Output (BTUH) 243,000 486,000 Second Stage 324,000 628,000 Steady State Efficiency ( %) 81.00 81.00 No. Burners 1 2 No. Stages 2 2 Gas Connection Pipe Size (in.) '/. 1 Electric Heat KW Range 54-108 Capacity Steps: 2 Compressor Number/Type 3/Scroll Size (nominal) 16 Motor RPM 3450 Outdoor Coil — Type Lanced ltrbe Size (in.) OD 3/8 Face Area (sq. ft.) 69.79 Rows/Fins Per Inch 2/16 Indoor Coil — Type Hi- Performance Tube Size (in.) OD 'h Face Area 37.50 Rows/Fine Per Inch 3/13 Refrigerant Control TXV Drain Connection No/Size (in) 1/1.25 Type PVC Outdoor Fan Type Propeller No. Used /Diameter 4/28.00 Drive Typo/No. Speeds Direct/1 CFM 31,700 No. Motors/HP/RPM 4/1.10 /1125 Indoor Fan Type FC No. Used 1 Diameter/Width (in) 25.00/25.00 Drive Type/No. Speeds Belt/1 No. Motors/HP 1/10.00,15.00,20,00 Motor RPM 1760 Motor Frame Size 2151254/256T Exhaust Fan Type Propeller No. Used/Diameter (in) 2/26.00 Drive Type/No. Speeds/Motors Direct/2/2 Motor HP /RPM 1.0/1075 Motor Frame Size 48 Filters — Type Furnished Throwaway No/Recommended Size (in) 17/16 x 20 x 2 Refrigerant Charge (Lbs of R•22) 23.90/49.50 per circuit Minimum Outside Air Temperature For Mechanical Cooling 0 F Notes: 1. Cooling Performance is rated at 95 F ambient 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. Tested in accordance with ARI Standard 360. 2. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 4,500 feet. 3. Steady State Efficiency Is rated In accordance with DOE test procedures. 4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 5. Maximum KW ® 240V - 54. • - - - 4 - • • • - - 31 1/2 - 17 1 11/16 19 11/16 --- 34 7/6 17 17 1/4 56 1/2 11 It RETROMATE ADAPTER FOR NE1Y TRAM.' TED 480 - 600 /EXISTING SAHA 400 14 500 ■ 20 GA. BOTTOM .-••■••■•••••••••••••• AIIIMOMMIN1.1■1••••■=11111•15. 254 7/8 1 14 GA. r-INSUL 1 CHANNEL gi_EvAlioN • 248 C/F ELAN 103 )/6 21 11/18 a- SENO (1) I3JN3LE OF .ROLIED INSULATION/CURO ( ) REO'D. SEND 150 FT. 1 1/2 x 1/4 GASKETING/CURD TAG: 5 1/2 79 3/4 OD i..-....----- 69 3/0 -- 111 / 4 r --„-- ,„ , E ---- , ,„ 1 1/2 x 1 1/2 1 ' 111 1/13.4 / 1 ORACRIG tt:' 10 / 26 --.1(1- / _1J L 1 vr.~••••••■ 22 GA. LINER (SUPPLY OHL 00 3/4 0/1: 5 V2 67/6 14 GA. GUSSET - C> rr 4 co a: oucr LINER 5.E.CIULAA. 5CC11014 8B 14 CA. g GALVALU1AE PO rr .14 GA. P.) GUSSET 30" O.C. tri D.• cr. (. 0 C4 C4 0 41) [NJ �oo� '1.\S7"\1'Cr tz\stl% 1 C oti.eRZ %Sc; suk vN ‘7" ).\%7 \tC — Cx ck 11" N G- tcQN L. R`'c pv�T