Loading...
HomeMy WebLinkAboutPermit M97-0150 - KODAK PROCESSING LABSgoaessi ��5 r i" 0 50 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M97 -0150 Type: B -MECH Category: PARES Address: 1233 ANDOVER PK E Location: Parcel #: 352304 -9084 Contractor License No: SEAAII *206JQ TENANT KODAK PROCESSING LABS 1233 ANDOVER PK E, TUKWILA WA 98188 OWNER VALLEY PROPERTIES 6051 SOUTH 194TH ST, KENT WA 98032 CONTACT DAVE ANDRINGA 946 INDUSTRY DR, TUKWILA WA 98188 CONTRACTOR SEA -AIRE INCORPORATED. 906 INDUSTRY DR,• TUKWILA, WA :98188 (206) 431-3670 Status: ISSUED Issued: 10/17/1997 Expires: 04 /15/1998 Phone: 206 575 -8051 Phone: 206 575 -8051 ********************************************* * * * * * * * * * * * * * * * * * ** * * * * * ** * * ** Permit Description: PLACEMENT OF 5 TON ROOFTOP PACKAGED AIR CONDITIONING UNIT UNDER 2000 CFM. UMC Edition: 1994 .. Valuation: 9,237.00 Total Permit Fee: 42.81 Permi * * * * * * * ** ************************** * * * * * * ** * * * * * * * * * * * * * * * * * * * * ** Cente uthorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing' work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: bww`Q.- Date: 1 c`J7- 97 Print Name: DA /q . Title: 259L&S 44ii11APg This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the inspection. Project Name/Tenant: 0,4 k L p2oce.5S, AJG- 19-11 Value f nstruction: ci as 7 Site Address: I �- 3 3 a v-e4. Pe -t.t. e City State /Zip: Tax P. cel Number: .:: ' - • - vSS. - on v e fA 9a rri ___Ign/i Property Owner: T vim T L C4'14-tEd,i 7 _ Phone: S - 8 8 s N Street Address: City State /Zip: Fax #: s. 7,5" — c/ 10 Contact Person: , 1.}. -NE fist.) DA , 46'4 0 Sewer S _ S - 8 0 5' I Street Address: City State /Zip: Fax #: S 75. _ O (O S Contractor: Sc - 4 II .. d` Phone: s '7S - 8�s 1 Street Addr / 1-- dt, City State /Zip: Fax II: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS ;PERMIT REVIEW ' AND ' APPROVAL '. REQUESTED :ITO.BE:FILLED'OUTBY APPLICANT).-; Description of work to be done: 5 'lOra Re, cF i P %'Ac khp ... A ! C O A y 0 ° 1 ,7- UnaQrz ZuUa cr.vl _ Will there be storage of flammable /combustible hazardous material in the building? ❑ yes r in no Attach list of materials and storage location on so•arate 8 1/2 X 1'I •a•orindicatin• • uantities & Material Safet Data Sheets Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof ❑ Demolition ❑ Fence ❑ Mechanical ❑ Manufactured Housing - Replacement only El Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems El Temporary Facilities El Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Address: MISCPMT.DOC 7/11/96 CITY OF TU - WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Date appli: c CI flai • Date a 36 , qg FOR AFF USE ONLY Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT.REQUEST,FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt it ❑ Water Meter /Permanent ❑ Water Meter Temp # ❑ Miscellaneous El Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq, ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public El Streot Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: o Moving Oversized Load/Hauling Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Ap gOopnillals) BUILDING/ AUTHORIZ AGENT: 1 , �� OA CJVtti�0 s Date: c/ _3� •' ? CI Signature: ��W ��NER__�� OR Print name: ,1 t V �� ` �A0E R rj o Phon S`7,S 8 ( Fax Ii: S �S C6 y Address: 1,i c , :; ✓Ick)s) - ( D,� Commercial Reroof" City/S: k (a wA qd' / eY ral SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks- Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist No: M -9 CI Antennas /Satellite Dishes Submit checklist No: M -1 Awnings /Canopies - No signage Commercial Tenant Improvement Permit Bulkhead /Dock Submit checklist No: M -10 Commercial Reroof" Submit checklist No: M -6 Demolition : Submit checklist . No M -3, . M -3a El Fences - Over 6 feet in Height Submit. checklist : No: M -9 Land Altering /Grading /Preloads. Submit checklist No: M -2 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 E Mechanical (Residential & Commercial) Submit checklist No. M -8, Residential. only - H -6, H -16 Miscellaneous Public. Works Permits Submit checklist No H -9 Manufactured Housing (RED INSIGNIA ONLY). Submit checklist No: M -5 Moving Oversized Load /Hauling Submit checklist No: M -5 Parking Lots Submit checklist No: M -4 Residential•Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist . No: M -6 Retaining Walls -. Over 4 feet in height Submit checklist No: M -1 El Temporary Facilities Submit checklist No: M -7 CI Temporary Pedestrian Protection/Exit Systems. . Submit checklist . No: M -4 CI Tree Cutting Submit checklist No: M -2 L ALL MISCELLANEOUS • IT APPLICATIONS MUST BE SU TED WITH THE FOLLOWING: ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE~ PL`ANt:AND UTILITY PLANS ARE TO BE COMBINED ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT A STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building:Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property, owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. ! HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 9 , A MISCPMT.D C'•'7/11%95 { tir 'N4 ,J `• ,:17 4 • , (f i Permit No:. Ad.dr :e: `' 1.2 ANDOVER Su,i to • Tenant K ODAK, PROCESSING•'LABS . •Status: ISSUED • _Type B -MECH App ied: :09/30/1997 . Parcel #.352304 -9004 'k *•k%•k'k k''k* A•*****.* 4***• k. k• k'*.*'• k**'* *•k * * *A* *** ***•k * *'•k *•kk * *+k* k** ***•k•k•k`Ak**.** k k * *• k * Permit .Conditi 1'`. No changes ,w'i i.1 be made .,to : the .p1;ans unless approved 'by the Architect or Engineer and the -.Tu.4:.w.iJa ;Building: Diuision..: All permits, inspection records :and, apDr' oved plans s h a l l . be avai:'lable:at• the Sob site pr to the „- staat any con stru Lion. These: documents ire to :'tie r`t e ma.intainecl ava #'l- able until is gr ~ A.l l onnctructia'rr to;be clone.:. in' tioritormance wi >th • app Oved an : and requi rements ::of the Uniform Bui`ld.it g, Code 1 ,94 Editi as;amerideci_•, Unif Code (1 94 Edition) , ,;and Wasty ;i.nitors Energy C.od'e. (1994 Edition) •Validity::af • Permit. The 'van of- a permsi; :or :'approval ;of - plans , 4 ,specifi oat io`h d r , and shall 'n'ot be'`.con- str a per'mit tor,' or an approval .of., any v iolation t ; • at arty, : of the, p r,ov i ion's, of t<he : i l d i n9 :code or of any ot: er' :»rdiry'ance;,.af; the ur•isdlction ;.:: No permit presuming t o glue } ,'i uthor-i.ty to iv i u i a can 'the provisions of this c ;shat l� be oval id. • MAN r iCTURE,RS ' ° INSTALLATI'ON IN'STRUCTIQNS REQUIRED ON • SITE,. FUP TIHE BUXLDING' IN''. PECTQR REVIEW. Elea; rical,pe #ts- 'shall be ' obtained .t'hr'ough the Washington.. Stat Dth'I.s.ion of ',Labo,r ; and, Iridustri`.es and,'''a11 electri : : wortiI zwvi 1.1:'pe stn .. - • - - - -- • Issued:• .10/17/1997 COMPLETE NOT COMPLETE COMMENTS REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: REVIEWERS INITIAL C:ROUTE -F DATE DATE DATE - per chord CoN PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER M rt. O I 50_ DATE q30q PROJECT NAME �ppka_krreeSi n Lo.b DEPARTMENT: G DIVISION PREVENTION � 1 1 0 -9111 -! s6 M to 7 WORKS L j STRUCTURAL LI PERMIT COORDINATOR J DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 1 O' NOT APPLICABLE Ej TUES /THURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF 1 1 (If routed by staff, make copy to master file & enter Sierra.) DUE DATE 10 (O 4?? APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) El DUE DATE APPROVED I 1 APPROVED WI CONDITIONS ri NOT APPROVED (attach comments) 0 (Ccrtifcadon of occupancy required. Project: Pro e i � e of i� / ectiQn: Type . -- I :4,44 -t c I7. - Address( AT E Date called: 18-'13 Special Instructions: Date wa ted: 7 a.m. Requester: ; _ H Phone No.: 6---7 5 — s20 s 1 INSPECTI NO. CITY O TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 ...A. Approved per applicable codes. COMMENTS: Pr .1A La $42.00SPEC • N I EE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: it Aaiswe INSPECTION RECORD I Retain a copy with permit '4 - 7'U PERMIT NO. a1 : 1 0 Corrections required prior to approval. Date: (206) 431 -3670 Project: o t T r op egtin, 'Tech Date 711e1 _ 9 l I t A f ? 3 & P E Special instructions: : r ( /-e . i a r1 fDer Date wannt p� l a.m. :m. Requester. V Phone y: l�e:: r _ 5'05/ _ �....... »...- .........,.... �....� --- ... --•— - - ___...... . xay... mc:* nx :.a:nRSJ'MPii�'ll:Y '���:ts �; IN T TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 LI Approved per applicable codes. COMMENTS: Inspector Crib . $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permi P fre9L , G Date: Q -i -o tso PERMIT NO. (206) 431 -3670 Corrections required prior to approval. , Proj c I � � lflle �RUCf$,3ir .1, .._ Laj,<, Type of ins n� C f { ctio c.y ( !4 - ti .tis' '-I Address: r�o 'i" � Date called: Date wanted: I - 13 - 9g p 1 "'l.�` C� 11 1 L m . p .. Specia instructions: Requester: Phone No.: ' •5 - 75- go.51 I I INSPECTION NO. I I Approved per applicable codes. COMMENTS: Inspector: ofroE . W p 3 ►-rom 4 tea-- f� 44I•lM11.IRNMITMI.. INSPECTION RECORD . 1 Retain a copy with permi �� PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 =3670 Corrections required prior to approval. r 1 fl QA-w. iYa;. -- is (C —04). (a T (ti! AA—Tv-0 t/ r U- ex ► - � - IAWN 1 c-a /S-01 1& - A 4 L, Date: 1 14 iq $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: y _11 ae Type of inspe lop. " Address: ) 213 Ai r -� .- v.-IC. 1 )L e Date called: 1(1 _69, c 1 - 9 7 Date wanted: , 1)1 ° 0 , : ia.mO p.m. Special instructions: c (.. “le.- t g. n Requester: ''.. 4 ?2f�f.' e g V /! , ' e.--. er,i) (.5/0ec-c7 , Pr ect: Type of inspe lop. " Address: ) 213 Ai r -� .- v.-IC. 1 )L e Date called: 1(1 _69, c 1 - 9 7 Date wanted: , 1)1 ° 0 , : ia.mO p.m. Special instructions: c (.. “le.- t g. n Requester: ''.. P hone No.: �— s i s 8 SEY.J..an:A"wo:FnNtttat t' • INSPECTION RECORD Retain a copy with permi INSPE TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 J. PERMIT NO. (20.6),.,4313670 Approved per applicable codes. UZ Corrections required prior to approval. Inspector: < J ����� Date : 1 ,00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. Receipt No.:. Date: `b. k4** k*.*4* k*44.k4r **Atk* * *A•k4*4k•ksl*k4 kk*A *A *•k *•A *k *k•k** *A *** *•kA TY -: pF TUKWII.A WA �� TRANSMIT *k•k * *ck. ** *hk*kk.kk ** rr'**** *•k **' A ***kA* * **k:1k4kA *A *•k *44•.l4.* 1',RMNS.M3T .Number: R9700660 Amount: 42.E31: 10/17/97 12:44 Payment: Met6od::CHECK •14gtation,: a "EN -AIRE, INC,. Injt: NAB Permit No: M97 -()130 Type: 13 -MECH MECHANICAL PERMIT Parcel. No: 352304 -9004 Site Address: 1233 ANDOVER PR E Total Fees: 42.01 This Payment 42.81 Total ALL Pmts: 42.E1l Balance: .00 0,1 tA***** f** tit***** r1** **,l *•.h *,1h * *4 * *At7 ** %h4•h•► *4-A * *, *tok,‘ ** *•k Account Code E)ecription. ;000/345 830 PLAN CHECK— NOMRES 000/322.140 MECII LAICAL -- NONRES 5200 10/20 9719 Amount E3.56 34.23 TOTAL 42.81.. $ BALANCE DUE YES READY FOR ISSUANCE ATE CONTRACTORS LICENSE RE IS THIS CONTRACTOR IN THE SYSTEM? RED? NO DATE CALLED CALLED BY VISSER ENGINEERING CC. 19062 SE 320th St., Kent, WA 98042 (253) 630-4530 Fax: (253) 630 -8151 Mike Visser, P.E. Enclosure Sept. 29, 1997 Dave Andringa SeaAire 946 Industry Drive Tukwila, WA 98188 Re: New HVAC unit TC *060C Kodak Processing Labs, 1233 Andover Pk E Visser Engineering Project #97 -135 Dear Mr. Andringa: We have reviewed the information provided by you regarding a new rooftop HVAC unit at the above referenced site. Visser Engineering has determined that the roof structure is adequate as is, based the following conditions: • HVAC unit weight of 699 lbs., including curb and economizer, • HVAC curb must cross no less than 2 existing 11 -7/8 TJI /35 joists that are spaced at 32 inches on center and span between grids 6 and 7, as given in the 1985 design drawings.. The impact of the new unit to the building's foundation, and to the building's ability to resist seismic loads is nominal. Calculations are attached for the impacted roof joists and girders. Please call if you have any questions regarding the foregoing. Sincerely, CIT TUB S E P 3 0 1997 PERMIT CENTER Mq - 0 ISO VISSER FNGINEEFING CC. Calculation Sheet Title: Project: Client: Date: Page: K I �■ /�� ■rZ��' �� Q ■� ct �, i� ■■■■ / Fr r/d nitr r E ■■ ■■ ■■ MP . IMM IM g ■■■■ ■■ 111111111111111111111 EMIR �■ ■� �' ■ ■■ ■■■ ■ ■ ■■ 1111111111111111101111111111111 ■■■■ ■11MIN. i c, 4- I 1023111.111111 • MEV MIE 4 II r rememorami wanimom Erni= amminumintimi ilizarFEresiminmenumamummm. 111111 )111111,1111 grim III FAN . , I Ili mit mom • t .)N 4 Dead Load: Unit Weight Beg. trib width End trib width Roof: Floor: Int. wall: Ext. wall: 20 psf 12 psf 0 plf 0 Of 12 feet 0 feet Wall beginning 12 feet 0 feet Wall ending . 0 feet 0 feet 0 feet 0 feet Beam Reactions: Reaction Location Reaction 12 feet 0 feet 0 feet Beam # Unit Beam # 0 Beam # 0 12 feet 0 feet 0 feet 700 pounds 0 pounds 0 pounds Allowable Stresses Unit Weight LDF = 1 LDF = 1.15 Modifiers Bending, Fb ( +) Bending, Fb ( +) Shear, Fv Elasticity, E 2,400 psi 2,400 psi 165 psi 1,800,000 psi 2,760 psi 2,760 psi 190 psi 1,800,000 psi CF = 1 CR = 1.00 Live Load: Unit Weight Beg. trib width End trib width Floor: 40 psf 0 feet 0 feet Beam Reactions: Location Reaction Beam ft Unit Beam # 0 Beam # 0 12 feet 0 feet 0 feet 0 pounds 0 pounds 0 pounds Member Forces Dead +Live Dead +Live+Snow Maxinum Bending Moment: Maximum Shear:* 21480 ft. -lbs. 2990 lbs. 43080 ft. -lbs. 6290 lbs. VISSEI? ENGINEERING CO. Simple Beam Design Beam Number: Girder Beam Length: 24 feet L 0 A D I N G D E S I G N Snow Load: Roof: Beam Reactions: Reactions Beginning End *Taken distance 'd' from support unit weight 25 psf Beam # Unit Beam # 0 Beam # 0 Dead Load 3230 pounds 3230 pounds Project: 97 - 135 Client: Sea -Aire Date: 9/29/97 Page: Beg. trib width End trib width 12 feet 12 feet Location Reaction 12 feet 0 pounds 0 feet 0 pounds 0 feet 0 pounds Live Load 0 pounds 0 pounds Snow Load 3600 pounds 3600 pounds Required Section Properties Area, A = Sect. Mod., S = Mom. of Iner., I = 49.72 in ^2 187.30 in. ^3 2,020.55 in.^4 Provided Section Properties Area, A Section Modulus, S I= 105.00 in ^2 210.00 in. ^3 1260.00 in.^4 Provide: 8.75 x 12 Glu- lam,24F -V4 Ls. Lal.Atiot•rs), IV gal& ri 1100 . . . • • ••• • • 11 wire0 let' o.c. ' .(r• (r(g) • ••••■ • • rr ROOF . FRAIIVIIN 00 ::PLVA . • • - • . , . • . •• • . ,g2g rit•er•ite..' . • . . . • .. • • • 1 iEW Y4 2 4 eiLtAl • Ot•J . 1 :1' • '"'; • : . •••:.•la :•11. • • 411 . . • • • . . •511-1 us0••••-• ' ' ,150•1'..Vh."1" r:64, • • . • ' • N 3 .4;+ ; • 1 , 1 *.A.L ,1 :2 • • • . o• 0; .• All dlmensione are in Inches. EVAPORATOR SECT ACCESS PANEL 5 l / 4 2" ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) CONTROL a COMPRESSOR ACCESS PANEL. 43 /in / 393/ 1 13 /1• 13/ic CURB DIMENSIONS Data CLEARANCE 36 Dimensional 5- To Standard Etffl&eric 3 . 4 ' Ton High Efficiett:v 77 72 TOP PANEL l I• 2 DIA HOLE (UNIT POWER WIRESI Z�Is Tj9 DIA HOLE (UNIT CONTROL. WIRES) 469 46 771/4 CONDENSER FAN 43 3 4 CLEARANCE 18 HORIZONTAL 36 DOWNFLOW TYPICAL ROOF OPENING 33 CONDENSER COIL 14 39 46% CLEARANCE 48 \ CLEARANCE 36 Table 88-1 Maximum Unit And Corner Weights (Lbs) And Center Of Gravity Dimensions (In.) Tons 3 TC0036C/TCD037C 702/731 5411571 184/192 137/139 99/107 120/133 38/38 19/20 4 TC*048C/TC*049C 731/765 559/592 190/196 138/147 106/114 123/135 36/37 19/20 5 TC*080CITC*061C 751/821 579!633 194/284 143/156 109/121 134/152 36/38 20/21 6Y. TC*075C/TC*074C 819/852 630/863 198/207 1821173 123/130 150/153 39/40 21/21 7/ Unit Model No. TC*090C/TC*086C Single Compressor TCa090D/TC*091D Duel Compressor Modica's* tolls downtime end horizontal unlit. Weights Maximum Weights (Lbs) Corner Weights (Lbs) Center of Gravity (In.) Shipping Net A . 8 C 0 Length Width 878/861 689/873 229/213 177/173 130/130 153/156 39/39 20/21 940/953 751/765 264/265 182/188 130/135 175/178 36/37 20/20 8A TC *102C/TC *103C 1064/1393 857/1094 . 298/353 217/291 144/203 197/246 37/43 20/26 10 TCo120C/TC *121C 1088/1753 879/1385 302/468 225 /357 150/242 202/317 38/46 20/29 1214 TC *150C/TC *161C 1460/1776 1161/1408 389/474 307/349 205/248 260/337 42/45 28/30 15 TC *180B/TC *181C 1739/2309 1371/1850 482/635 350/464 227/317 312/434 45/52 28/35 171/2 TC*210C/TC *211C 1820/2380 1452/1921 500/643 378/495 247/341 327/442 48/53 28/35 20. TC *2408/TC *241C 2285/2470 1820/2011 814/892 462/523 319/343 4251453 53/53 35/34 25 TC*300B/TC*301C 2395/2475 1930/2016 651/895 490/524 338/343 451/454 53/53 35/34 NOTE 1. corner weights are given la Information only. 13SS -25 Ion models must be supported continuously by a curb or equivalent frame support. 2. Weights we approximate. Horizontal and downit w unit and corner weights may vary slightly. -��^- A T CENTER Of GRAVITY WIDTH D CENTER Of GRAVITY VANE- able 87-1 Accessory Net Weights (t,bsp lodel No. Co038,O48,080C "C *037,049 fCc075,O90C.O90O fCe081,074,086C.091 D, 1C*102C,120C TCD 1O3C TCD150C TCD1B08 TCO121,151C. TCO21OC TCD24OB TCD1B1,211.241C TCD300B.301C TCH1O3, 150C TCH180B,210C TCH121,151C Table 87 -1 (Continued) Economizer Outside Air Damper Oversized High" Low' Power Roof Motor Static Static Net Manual Motorized Exhaust' Curb' Adder Drive Drive 40 32 40 32 TC*036, 048.060C 1 20/20 TC*O37,O49 TCD180B. 210C TCD121.151C TCO240B TCD181,211.2416 TCD300B,301 C TCH103.121C,150C TCH240B 1 TCH181.211. 241C TCH300B. 3016 1 *In d CaaN both dovrhltow and horizontal unite. WeL ,hts 3.25 40 32 35 75 165 5 2 - — 65 32 60 95 205 5 2 2 80 32 75 95 235 • 5 2 BO 32 75 95 235 N/A 2 2 35 32 35 — -- 5 2 — 50 32 60 5 2 2 TCH240B as 32 75 — — 5 2 -- TCH181.211.241C TCH300R,301C 65 32 75 — — N/A 2 2 Unit All Zone 6-23 KW 27.36 KW 54 KW 72 KW Model No. Sensors 240/480V" 2401480V= 3 240/480V 3 240/480V' 3 TC *O75, 090C, 0900 1 26/26 26/26 TCe061,074,086C.091D, 1O2C, 1206 TCD1O3, 150C 1 28/21 31/27 38/32 1 1 1 28/21' 1 28/21 31/27 38/32 TCH180B. 2106 1 28/21' 31/27 38/32 TCH121.151C NOTES: t. Net weight should be added to unit weight when entering factory instated accessories. 2. For BOOV heaters net weights we aim u 460V healers. 3. To estimate shipping weight add 5 the to net weight. 4. Dovmhovt ony. 5. 27.36 KW heaters not available For 1CSO61C. 8. Not available on all models (See Fan Pedanwnce tables for specific models). 7. 9.23 KW Heaters not available for TC*210C, 80 5 35 87 65 31/27 33/27 33/27 82 38/32 40/32 40/32 33/27 40/32 33/27 40/32 5 Electric Heaters 1\,/ Q A/ 2 43/34 43/34 43/34 43/34 2 • TRAWl Table 9 -1 General Data 3 Ton Downllow Units TCD036C1, C3, C4 Cooling Performance' (dross Cooling Capacity 37,400 48,900 48,900 64,000 62,500 SEER' 10.00 10.00 10.00 9.85 10.00 Nominal CFM / ARI Rated CFM 1,200/1,200 1,600/1.600 1,600/1,600 2,000/2.000 2,000/2,000 ARI Net Cooling Capacity 36,000 48,000 47,000 61,500 60,000 System Power (KW) 4.01• 5.26 5.26 6.95 - 6.71 Compressor No./Type 1/Climatuff® 1/Climatuff 1/Climatuff 1/Climatuff 1 /Climatuff Sound Rating (GELS)' 8.2 8.6 8.6 8.6 8.6 Outdoor Coll -- Type Hi- Performance Hi- Perlonnance Hi- Performance Hi- Performance Hi- Performance Tube Size (in) 0.0. .375 .375 .375 .375 .375 Face Area (sq ft) 5.67 7.43 5.83 11.32 9.76 Rows/FP1 2/16 2/16 2/16 2/16 2/16 Indoor Coll - Typo Hi- Performance Tube Size (In.) .375 Face Area (sq It) 3.67 Rows/FPI 2/15 Refrigerant Control Short Orifice Drain Connection No/Size (in) 1// PVC Outdoor Fan - Type No. Used/Diameter (in.) Drive Type/No. Speeds CFM No, Motors/HP Motor RPM *Indicates both dowrdbw and horizontal units. Propellor 1/24 Direct/1 3,150 1/.25 850 Generai Data , ws 'wait 4 Ton Downfiow and Horizontal Units 5 Ton Dovmflow and Horizontal Units TCe048C1 TCe048C3, C4, CW TC4O60C1 TC*060C3, C4, CW Hi- Performance Hi- Performance Hi- Performance Hi-Performance .375 .375 .375 .375 4.83 4,83 6.33 6.33 2/15 2/15 2/15 2/15 Short Orifice Short Orifice 'Short Orifice Short Orifice 1/14 PVC 1/36 PVC ipA PVC 1PA PVC Propeller Propeller 1/24 1/24 Direct/1 Direct/1 3,940 3,630 11.33 1/.33 850 1,075 Propeller Propeller 1/24 1/24 • Direct/1 Direct/1 4,900 4,270 1/.50 1/.40 975 1,075 Indoor Fan -- Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No, Used 1 1 1 1 1 Diameter x Width (In.) 9 x 9 12 x 9 12 x 9 12 x 9 12 x 9 Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 Direct/2 No. Motors 1 1 1 1 1 Motor HP (Standard/Oversized) .33/40 .50/.75 .50/.75 .60/.75 .60/,75 Motor RPM (Standard/Oversized) 1075/1400 850/1040 850/1040 850/1040 850/1040 Motor Frame Size (Standard/Oversized) 48/48 48/48 46/48' 48/48 48/48 Filters - Type/Furnished? Throwaway/Yes Throwaway /Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes (No.) Site Recommended (In.) (2) 20 x 25 x 1 (2) 20 x 25 x i' (2) 20 x 25x I' (2) 20 x 25x 1 (2) 20 x25 x 1 Refrigerant Charge (Lbs of R -22)' 5.6 6.6 5.6 8,4 7.9 NOTES; L Cooling Performance Is rated at 95 F ambient. t10 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heel. ARI capacity is net and incl the elect of fm motor heat. Units am suitable for operation to ±20% of nominal cim. Rated in accordance with ARI Standard 210/240 or 360. 2. SEER is rated at ARt conditions and in accordance with DOE teat procedures. 3. Sound Rating is rated h accordant, with ARI Standard 270 or 370. 4. Refrigerant charge is an approximate value, For a more precise value, see unit nameplate and service instructions. 5. TCH046 models require (2) 16 x 25 x 1 fillers 8. TCD036C3, C4 system power KW 3.99. 9 VI ENGINEERING CC. 19062 SE 320th St., Kent, WA 98042 (253) 630-4530 Fax: (253) 630 -8151 Sept. 29, 1997 Dave Andringa SeaAire 946 Industry Drive Tukwila, WA 98188 Re: New HVAC unit TC *060C Kodak Processing Labs, 1233 Andover Pk E Visser Engineering Project #97 -135 Mike Visser, P.E. Enclosure Dear Mr. Andringa: We have reviewed the information provided by you regarding a new rooftop HVAC unit at the above referenced site. Visser Engineering has determined that the roof structure is adequate as is, based the following conditions: • HVAC unit weight of 699 lbs., including curb and economizer, • HVAC curb must cross no less than 2 existing 11 -7/8 TJI /35 joists that are spaced at 32 inches on center and span between grids 6 and 7, as given in the 1985 design drawings.. The impact of the new unit to the building's foundation, and to the building's ability to resist seismic loads is nominal. Calculations are attached for the impacted roof joists and. girders. Please call if you have any questions regarding the foregoing. Sincerely, MEWED CITY OF TuIKWI .A SEP 301997 PERMIT CENTER Mq1 0150 viSSER ENGINEEI?IM3 co. Calculation Sheet Title: Project: Client: Date: Page: IIPERNIMINMENEUIPME0MS 6911112 11/111111111111 111111 H•••■G lk � lul L� EM 1111111E orrammia Imo INIMERFAMEr MIIMEMEM 1111111111111111111111111111.111 11.1111111.1 1 ,���l 11 N 1� 11111E11M 1111111 111111111211M1 e. S'3 1..P F 7 if h Dead Load: Unit Weight Beg. trib width End trib width Roof: Floor: Int. wall: Ext. wall: 20 psf 12 psf 0 plf 0 plf 12 feet 0 feet Wall beginning 12 feet 0 feet Wall ending . 0 feet 0 feet 0 feet 0 feet Beam Reactions: Reaction Location Reaction 12 feet 0 feet 0 feet Beam # Unit Beam # 0 Beam If 0 12 feet 0 feet 0 feet 700 pounds 0 pounds 0 pounds Allowable Stresses Unit Weight LDF = 1 LDF = 1.15 Modifiers Bending, Fb ( +) Bending, Pb ( +) Shear, Fv Elasticity, E 2,400 psi 2,400 psi 165 psi 1,800,000 psi 2,760 psi 2,760 psi 190 psi 1,800,000 psi CF = 1 CR = 1.00 Live Load: Unit Weight Beg. trib width End trib width Floor: 40 psf 0 feet 0 feet Beam Reactions: Location Reaction Beam # Unit Beam II 0 Beam # 0 12 feet 0 feet 0 feet 0 pounds 0 pounds 0 pounds Member Forces Dead +Live Dead +Live+Snow Maxinum Bending Moment: Maximum Shear:* 21480 ft. -lbs. 2990 lbs. 43080 ft.-lbs. 6290 lbs. . VISSE12 ENGINEERING co. Simple Beam Design Beam Number: Girder Beam Length: 24 feet L O A D I N D E S I G N Project: 97 - 135 Client: Sea -Aire Date: 9/29/97 Page: Snow Load: Roof: Beam Reactions: *Taken distance 'd' from support unit weight 25 psf Beam # Unit Beam # 0 Beam # 0 Required Section Properties Area, A = 49.72 in. ^2 Sect. Mod., S = 187.30 in. ^3 Mom. of Iner., I = 2,020.55 in. ^4 Beg. trib width 12 feet Location 12 feet 0 feet 0 feet End trib width 12 feet Reaction 0 pounds 0 pounds 0 pounds Reactions Beginning End Dead Load 3230 pounds 3230 pounds Live Load 0 pounds 0 pounds Snow Load 3600 pounds 3600 pounds Provided Section Properties Area, A = 105.00 in. ^2 Section Modulus, S 210.00 in. ^3 I == 1260.00 in. ^4 I� Provide: - 8.75 x_12 Glu- lam,24F -V4 All dimensions are in inches. EVAPORATOR SECT ACCESS PANEL — 5 2" ELECTRICAL CONNECTION {SINGLE POINT POWER WHEN HEAT INSTALLED) CONTROL R COMPRESSOR ACCESS PANEL CURB DIMENSIONS Dimensional . 5 Ton Standard EUic:ienc +.1 K 4 Ton High Efficiency Data 43 393/15 1 )13 /la` �e CLEARANCE 36 77% 72 TOP PANEL �Ia 469 16 77 CONDENSER FAN 43% CLEARANCE IS HORIZONTAL 36 DOWNFLOW TYPICAL ROOF OPENING 33 CONDENSER COIL 2 DIA HOLE ( UNIT POWER WIRES) T/ DIA HOLE (UNIT CONTROL WIRESI 39 46 9 46 ��' 1 1 1 CLEARANCE 36 Table 88 -1 Maximum Unit And Corner Weights (Lbs) And Tons 3 4 5 6y 714 Unit Model No. TCD036C/TCD037C TC*048C/TC*049C TC*060C(TCe061C TC*075C(TC *074C TC*090C/TC*086C Single Compressor TC*0900/TC*091D Dual Compressor *Indlosses both dominos/ and WI/0M units. 702/731 731/765 751/821 819/852 Weights Maximum Weights (Lbs) Shipping= Net 878/861 689/673 940/953 751/765 264/265 182/188 130/135 175/176 36/37 1064/1393 857/1094 298/353 217/291 144/203 197/246 37/43 1086/1753 879/1385 302/468 225/357 150/242 202/317 38/46 1460/1778 1161/ 1409 389 /474 307/349 205/248 260 /337 42/45 1739/2309 1371/1850 482/635 350/464 227/317 312/434 45/52 1820/2380 1452/1921 500/643 378/495 247/341 327/442 46/53 2285/2470 1820/2011 614/692 462/523 319/343 425/453 53/53 2395/2475 1930/2016 651/695 490/524 338/343 451/454 53/53 Sys TC *102C/TC *103C 10 TC *120C(TC *121C 1214 TC *150C/TC *151C 15 TC *180B/TC *181C 1714 TC *210C/TC *211C 20 TC *2408(TC *241C 25 TC*300B/TC*301C NOTE Comer weights we given for Information only. 81425 ton models must be supported continuously by a curb or equivalent frame support. 2. Weights we epproxlmale. Horizontal and downllow unit and corner weights may vary slightly. T �^ A CENTER OF GRAVITY WIDTH 0 541/571 559/592 579/633 630/663 CENTER OF GRAVITY CENTER OF GRAVITY LENGTH Center Of Gravity Dimensions (In.) Corner Weights (Lbs)' Center of Gravity (In.) A • B C D length Width 184/192 137/139 99/107 120/133 38/36 19/20 190/198 138/147 106/114 123/135 36/37 19/20 194/284 143/156 109/121 134/152 36/38 20/21 196/207 1621173 123/130 150/153 39/40 21/21 229/213 177/173 130/130 153/156 39/39 20/21 20/20 20/26 24129 26/30 28/35 28/35 35/34 35/34 7 WANE' able 87 -1 Accessory Net Weights (Lbs)' lodel No. C*038,048,0600 "C*037,049 rC *075,090C,090D rC *061,074,086C.0910, TC*102C,120C TCD 103C TCD150C TCD180B TC0121,151C. TCD210C TCD240B TCD1B1,211.24IC TCO3008.301C TCH 103, 150C TCH18013,210C TCH121,151C TCH240B TC0103. 150C TCD180B. 210C TCD121.151C TCD240B TCD181.211.241C 1CO3008.301C TCH103, 121C, 150C TCH1808. 210C TCH121.151C TCH240a TCH1B1.211. 241C TCH30013. 301C Table 87-1 (Continued) Economizer Net *lndlcatea both downllow and horizontal units. 40 32 1 1 1 1 1 1 Wei 'Its Outside Air Damper Motorized Manual TC *038, 048. 060C 1 20/20 TC #037,049 • 28/21 28/21' 40 32 35 65 82 5 2 40 32 35 75 165 5 2 65 32 60 95 ' 205 5 2 2 80 32 75 95 235 5 2 60 32 75 95 235 N/A 2 2 35 32 35 — — 5 2 60 32 60 — — 5 2 2 TCH181,21 L241C 65 32 75 -- — 5 2 — TCH300B,301C 65 32 75 — -- N/A 2 2 Unit All Zone 6-23 KW 27.36 KW 54 KW 72 KW Model No. Sensors 240/480V 240/480V' 3 240/4B0V 3 240/480V' 7 TC *076, 0900.0900 1 26126 26126' TC *061,074.086C.091D, 102C, 120C NOTES: 1. Net weight should be added to unit weight when ordering factory installed accessories, 2. For 600V healers nel weights are same as 480V heaters. 3. To estimate shipping weight add 5 lbs to net weight. 4, Pownitow only. 5. 27 - 36 KW Healers not available try TC*061C. 6, Not available on all models (See Fan Performance tables for specific models), 7. 9.23 KW Heaters not available for TC*210C. 87 Power Roof Exhaust' Curb' 31/27 31/27 33/27 3 Ton 80 Oversized High' toe Motor Static Static Adder Drive Drive 38/32 38/32 40/32 33/27 40/32 1 28/21 31/27 38/32 1 28/21' 31/27 38/32 33/27 40/32 33/27 40/32 5 o N 43/34 43/34 43/34 43/34 Pa • Table 9 -1 General Data Compressor No./Typo Sound Rating (GELS)' *Indicates both downnow and horizontal units. ( :; General Data 3 Ton Downftow Units TCD036C 1, C3, C4 1 /Climatuff® 8,2 9 • 1 •ft ".■ -r te r I. 4 Ton Downflow and Horizontal Units 5 Ton Downitow and Horizontal Units TC4048C1 TC*048C3, C4, CW TC *060C1 TC*060C3, C4, CW Cooling Performance' Gross Cooling Capacity 37,400 48,900 48,900 64,000 62.500 SEER' 10.00 10.00 10.00 9.85 10.00 Nominal CFM / ARI Rated CFM 1,200/1,200 1,600/1,600 1,600/1,600 2,000/2,000 2,000/2,000 ARl Net Cooling Capacity 38,000 48,000 47,000 61,500 60,000 System Power (KW) 4.01° 5.26 5.26 6.95 - 6.71 1 /Climatuff 1 /Climatuff 1/Climatuff 1 /Climatuff 8.6 8.6 8.6 8.6 Outdoor Coll --Type HI- Performance HI- Performance Hi- Performance Hi- Performance Hi•Performance Tube Size (In.) O.D. .375 ,375 .375 .375 .375 Face Area (sq II) 5.87 7.43 5.83 11.32 9.76 Rows/FPI 2/16 2/16 2/16 2/16 2116 Indoor Coll -- Type HI•Performance HI- Performance Hi- Performance HI- Performance HI•Performance Tube Size (In.) .375 .375 .375 .375 .375 Face Area (sq II) 3.67 4.83 4.83 6.33 6.33 Rows/FPI 2/15 2/15 2/15 2/15 2/15 Refrigerant Control Short Orifice Short Orifice Short Orifice 'Short Orifice Short Orifice Drain Connection No. /Size (in.) 1/Y PVC 11/ PVC 1PA PVC 1135 PVC 1 PA PVC Outdoor Fan - Type Propeller Propeller Propeller Propeller Propeller No. Used/Diameter (In.) 1/24 1/24 1/24 1/24 1/24 Drive Type/No. Speeds DirecVi Direct/1 Direct/1 • Dlrect/I Direct/1 CFM 3,150 3,940 3,630 4,900 4,270 No. Motors/HP 1/.25 1/,33 1/.33 1/.50 1/.40 Motor RPM 850 850 1,075 975 1,075 Indoor Fan -- Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used 1 1 1 1 1 Diameter x Width (in.) 9x9 12 x 9 12 x 9 12 x 9 12 x 9 Orivo Type /o, Speeds Diroct/2 DirecV2 DirecV2 Direct/2 Direct/2 No. Motors 1 1 1 1 1 Motor HP (Standard /Oversized) .33/40 .50/.75 .50/.75 .60/.75 .60/,75 Motor RPM (Slandard/Oversized) 1075/1400 850/1040 850/1040 850/1040 850/1040 Motor Frame Size (Standard /Oversized) 48/48 48/48 48/48' 48/48 48/48 Filters -- Type/Furnished? Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes (No.) Size Recommended (in.) (2) 20 x 25 x 1 (2) 20 x 25 x 1' (2) 20 x 25x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 Refrigerant Charge (Lbs of R -22) 5.6 6.6 5,6 8.4 7.9 NOTES: 1. Cooling Performance Is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not Include the effect of tan motor heat. AR capacity is net and includes the ellect of Ian motor heat. Units ere suitable for operation to ±20% of nominal cim. Rated In accordance with ARI Standard 210/240 or 360, 2. SEER Is rated at ARI conditions and in accordance with DOE teat procedures. 3. Sound Rating Is rated In accordance with ARI Standard 270 or 370. 4. Refrigerant charge Is an approximate value. For a more precise veto°, see unit nameplate and service instructions. 5. TCH040 models requite (2) 18 x 25 x I fillers 6 TC0036C3, C4 system power KW 3.99. • )1. of( �r•. - Department of k , .is action and L d II Boiler/Pressure Systems Inspection Sectio Steam & Refrigeration Licensing 710 - 2nd Avenue, Suite 700 Seattle WA 98104 -1703. SEA -AIRE INC 906 INDUSTRY DR TUKWILA, WA 98188 7/9/96 Expires: 7/31/97 License No: 19812 REFRIGERATION CONTRACTOR, AIR CONDITIONING Limitation: None 1,11.7 ts,J.ilitnaitill•h Department orCoastruedon • andl.ind �. ,�.. t ,f Wier/Pressure Systems nspection ••- Steam i Refrigeradon Limning • • `` ° - 710.2nd Avonuo, Suito 700 Seattle, WA 98104 -1703 SEA -MRE INC 7/9/96 • 906 INDUSTRY DR, TUKWILA, WA 98188 EXP: 7/31/97 Refrigeration Contractor, Air Conditioning Limitation: None License No:19812 • m 0 CNV • • • `D .., :.a .. • 'a . I. • ... , 0 z 0, m C) m m v CO LICENSE TYPE BUSINESS LICENSE BUSINESS LOCATION SEA —AIRE' INC 906 INDUSTRY DR TUKLIILA- WA SEA —AIRE SEA —AIRE 906 TUKWILA F - , E D e 2A• 9 ( _ l 1 D A 3 51* D. W. Gentry, Chief In Please detach both licenses. Display the above Iicensa.in a cor. The wallet - size license at left is included for your cor)venience. . . -'.• t t !- I.2 !!!/.V%Y.!l:!YC'!N ! rW .lW)��l .fY�ifliVZ�I�L` •k'' The City Of Seattle Department of Finance. Revenue and Consumer Affairs Division 600 4TH AVE. RM 103 SEATTLE, WA 98104 -1893 (206) 684 -8484 • CUSTOM 1981,2: EXPIRA 12/ 01/, POST CC NOT TA MAILING ADD INC I a • 'c(c' INDUSTRY I WA• 11111111111 11111I11I1IIIIIII1111111I1111111111111II1E11111 1111 I'I tl 4 \� II 2 1 - ® . G +o =gip n vc - Q -. _ - v- . O -�i E� _ •\ - s?t °IO v". `... G• 't tai `•'-y 'F •�, - I f '*i�1 ((4 A(1, Ga,ral,cl `� } f' 7 \,i, „V: s.i'S�A�1.Ft� I i fi P 3 I 11 0 G 1 _-: r - - -'-� ,° 1.- ra• i3 ,..01, -g? ,-, o •- I {csl icry 1 y.F* , ..0 4 .1 -- -� -- 1 I I ` -v-- -, .. _ `., i - ° r., k ° 1 -ice ° i� ® ' _, �I� �� , } OOi I J t C • . �sTd' .T R� 7 G rca.c. 1'.11a:rvTtS�1 >: i^ oncr65t;5 9. c1�T" .SCN : ✓Gl7r /fkgeeS ) _ - �) AI-1 9PR /N�iL��:'7a.J°il iy • Plus- NC /.�.s�.iu.��: "3Cfy.81.s j s�fti CGi- /'�3C- CON•"Or 4) til,"ati7M�lr7:C=. - If' -• 9-v- 5' Cr2,vS •. —_ %C is.e7•, liii r�3C .e15�sT� �Y G)' -: S .e.. As.L. fs�.vcf T.� TAP c�,ef.� a�•✓F _ I - ?3al /L97 /F/ •• LN ��a'[la�J.- ".jai,_: ✓'::7t.i;c.','e iT�, -7'c�:. . ave been' e City of - s,. deletions . ✓ings after this thrice and will .'. viseddrawings. field - his is subjec. epresentative TUKWILA FIRE.DEPAR Please call:. 575.4407 and give this job and exact address for shut•= clown or restoration approval:.' RTr ra'd.+ s per,. cacti �7tc , s•s S< rs r `'r , coyly w�a+yv RECEIV �es�ofiif fi�iFitv��s �+se�aal 3 �' F OCT 2,1 TUI:WILA IRE PREVENTION Tt:e drav✓in• .tfxed: heret 1 ewed and a�. epted by Tu wila•Fire Dep - ddit'• or visions - totlses .r da ' will void this ad . r.: WITHOUT' - -_ COMMENTS. NOTED IN RED: THE ATTACHED E INCHES muc To d TEMP. 0165 g:86 .$212. uL 6WTERMLS 6 EbIINMEftr TO BE NEW 6 .. owNEri ro PBwwE �BEOi7..TE HE ro.FEF PwE FPOM FBEFIIN6 • eoo a niidd_ ': T : NOD b RING. AREA CODE U FACTOR ENERGY LASS ?:(Q),: .. TEMP " ENERGY LOSS. (Q) GROSS WALL 5660 S.F. - - 0.25 (70 - - 221 ° F -;. QW-• •r�: 67,900 Btu /HR ROOF AREA 7300 S.F. 0.05 (70- -22) ° F Q 17,520 - - _ Btu /HR . SLAB PERIMETER 360 FEET SLAB F FACTOR 0.23 (70 - 55) °F ,:1 - -� Btu /HR AREA CODE U FACTOR TEMP ENERGY LASS ?:(Q),: .. GROSS. WALL C:'_1.: (70 .22) ° .F o 29,885 Btu/HR ROOF AREA . •3.05 - ('O - 22) ° F 17,520 Btu /HR J SLAB PERIMETER SLAB F FACTOR 0.46 (70 - 55) ° F -Q ; - - 2,495 Btu/HR I OJ S 6x8" CD CM) ,f L?x(o° 100 CFM CD (N) 80 CFM 8 ° x9' CD (N) TYP OF 4 AHU -1 HP -2 IO L4"x 4 RAG (N) A 8.8 V RELO A I IUN 0 - 4 - /VON\ CE) y EXISTING ROOF TOP T- UNIT - REUSABLE,-' O'DIAC DN'.( /4 DIACN) IB DIACN) it A IBO CFM (EF Y 8 UP TO RocF - FAN IS EF - 4 N G ° ' G" RAC, (N) G "TAG (N) TYP OF 0 IC, 0 2 qT 0 (5O 50000/4 c/ G (N) 500 000' zo x 6 SAR O) 500 CFM 20T 6" SAR (N) 500 c/ H ER-2_ 20'x(n" SAR 0) 210 CFM (WII -(1 < mo_ B" B uP TO WII 1 LOK20' 400 REM SAR CN) z< xzo�� 500 CFM ((( /G "SAR (N) IOH _ H 000 CFM GO - <6 " / 0 4)0 24'424 RARE 500 CFM CO' *0 "51 (N) 3 C M Z "r6 300 CFM H - �� EF - 3 300 crM To'I, n" SAR (NI R � 8 N UP T(J W FI C a < 24`x -4 ' RAG (N) - 00 CFM' 20 'C°' ' N) ( 12 12' (N) ,s 2d 02 20 2011,2.6'7_1 zOCCFn� 20�a6' S .9 R (N1 NOT OA O (VAP. OO / MOUNTED ON TOP F RM.,ANU oN CE ING f COPPER LINE BETWEEN G"oG'� RAG T OF 5 RELOCATE XISTING GRILLE AS SEFIOWN TYP 14 0IACN) 250 CFM �ID'DI 8" =8 "CD(E) TYP OF 4 1( / ,e'', � SO CFM 6 "x6' c o 5 (N) [ ZOO , TYP OF 'S -- 1I ACTUAL PROPOSED. ENERGY ;,LOSS ....,: 9x2_4' RAG (El HVAC FLOOR PLAN SCALE I/8'= I NEW ADDIT./ON ONLY. ENERGY CODE REQUIREMENTS „tTOTAL: Q = 86,662:Btu /HR' - 49, ^'890)Btu /HR ? 200 CFM ” 8"x8 CE (El Z Y P O F 150 REM 8 " +B" CD (E) TYP OF 3 U 1` BOHN 'ASPERA' P-1 CARRIER 50QD -008, 87;000 208/3 i HP -2 CARRIER : 500D -008 37 ;. 20 8/3 2.05 ;AP 2 'AMMERMAN AMMERMAN AMMERMAN AMMERMAN' :.ACCESSORIES ECONOMIZER,. ELECTRIC RESISTANCE. HEATERS, THERMOSTAT,, SINGLE FT. BOX CAPACITY - (Btu /HR) VOLT /0 MIN OOP CAPACITY (Btu /HR) VOLT /0 MIN COP ADT 040 12,000' 115/1 N /A;� MT -6213C .115/1_ :MODEL 3611 PS -8 -2 PH-8-20 CAPACITY (Btu /HR ) 25 0 VOLT /0 120 /1. 120/1 120/1 120/1 MIN COP N/A N/A N/A ' ACCESSORIES THERMOSTAT - 24" RAG (N) ZOO CFM 8'x8` (DOE) TYP OF 2 EX I STING ROOF ToP UN)T - REUSABLE EF -1 100 CFM vP TO Ex /ST/ NG WOO Y B " Din(t) 11\ I '5o44 - ' L -I RELOCATE TO NEW LOCATION 8 "DIA(E) LEGEND = OF MECHA SYMBOLS SYMBOL'' "ABBREV: CD RAG EF DI-I EAU" DESCRIPTION. CEILIN DIFf USER .SIDE S .DUCT :LONNECT. SNoWN RETURN AIR. .- ..GRI LLE THERMOSTAT CONTROL; EXHAUST FAN :TRA !t GRI LLE ° , ` 'EX I5TE G DUCT • HEAT E N • -ER/ST/MG ELECTRIC H EATING UNIT. H SAR SI DE WALT. SUPPLY AIR REGISTER`< ' NOTE: DASHED LINE INDICATE MATERIALS TO BE REMOVED OR RELOCATED WHERE SNOWN DgRO LNNES INDICATE NEW MATERIALS LOGO (.5C,LI O) LINES INDICATE EXISTING EYIAIER',ALS TO REMAIN