Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M97-0179 - CHEVRON GAS STATION
h ev Roo Y' qriQ -79 City of Tukwila C Permit No: M97 -0179 Type: B -MECH Category: NRES Address: 14620 PACIFIC HY S Location: Parcel #: 004000 -0910 Contractor License No: POLARSR066RT Signature: Print Name: mac ' "fl — G / Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT TENANT CHEVRON 14620 PACIFIC HY S, TUKWILA, WA OWNER LAKHA INVESTMENTS LLC Phone: 206 487 -0988 19119 NORTHCREEK PY, BOTHELL WA 98011 CONTACT SCOTT GIEBEL Phone: 425 -323 -8940 19424 74TH AVENUE WEST, LYNNWOOD, WA 98036 CONTRACTOR POLAR STAR REFRIGERATION CO Phone: 425- 323 -8940 19424 74TH AVENUE WEST,`LYNNWOOD, WA 98036 **** * * * * *,4 * * * * * * * * * * * * * * * * * * * * *9l * * *** * * * * * ** **4(* k** * **** * *fit * * * ** * ** *fir * * * *** Permit Description: HVAC INSTALLATION AND WALK •IN COOLER /FREEZER. COMBINATION. UMC Edition: 1994 Valuation: Total Permit Fee: (206) 431 -3670 Status: ISSUED Issued: 12/29/1997 Expires: 06/27/1998 * * * * * * * * * * * * * * * * * * * * * * * ** p-a -9; 50 000.00 98.94 Per it ent: Auth rizd'Si.gnature Date I hereby certify that I•have read and examined this permit and know the same to be true and correct. All provisions .of law and ordinances, governing ',this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to. violate or cancel,the 'provisions of any other state or local laws regulating construction, or the performance of work.. I am authorized to sign for and obtain this building per. Date: /p Title: Iza -,emu This permit shall become null. and void if the work is not commenced within 180 days from the date of iss or if. the work is suspended or abandoned for a period of 180 days from the last inspection. Project Name/Tenant: , !� /20 ,�`� Description of ork to be done: lig - 1 t /i'N D w , ✓ Goi Va of Construction: / 9ro � Site Address. >'�L�'� 1'' State/Zip: Cit y P - ' f , r v S. RAW ,T-fr-, Tax p r/ reel u b r: . 'L I --0 /0 Property Owner: 711/kw/ / e `✓e- e7A0LA'1,D G1 . -o T ✓ w u Phone: 5.57 (o Street Ad• ess: r pity Stat , Z�i(� : Jo ist - P.E. t if 1 &oik WK l� Fax #: ‘114 417 die/ � L , 4 - .-J G� l� Contact Perso� I QiL City /State /Zip: Pho Pho Street Addres • City State /Zip: • ./ i Pie-1 v ore. ? 7n 32-0-041 0 Contractor: IZ �rxY STA �, Phone: & - 3e 3 ' 0505 Street Address: 2 fig lit; i wv, _ i Architec,S.:_, )5;1 -, mac l- at9�/,5'z/V City State /Zip: . e :o3L0 Fax #: 2o& - 7/2 °o('/ j' Phone: 2 Cr - Z 5 / - 6 z7.-Z StreeLAddre : /TiZ /5 72 Avg &r,'n" /2e-ft /- wit- City State /Zip: 1 u632 Fax It: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT. REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of ork to be done: lig - 1 t /i'N D w , ✓ Goi Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑"'n`o Attach list of materials and stora a location on separate 8 1/2X�11 paper indicatin uantities & Material Safety Data Sheets Above Ground Tanks u Antennas /Satellite Dishes LJ Bulkhead/Docks Commercial Reroof ❑ Demolition ❑ Fence `Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Address: Miscellaneous Permit Application Name: MISCPMT.DOC 7/11/96 CITY OF T'P'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. WATER METER DEPOSIT /REFUND BILLING: APPLICANT. "REQUEST: FOR MISCELLANEOUS PUBLIC WORKS PERMITS': ❑ Channelization/Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading/clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt it Size(s). 0 Deduct 0 Water Only ❑ Water Meter /Permanent It Size(s): ❑ Water Meter Temp # Size(s: Est. quantity: gal Schedule: ❑ Miscellaneous_ Moving Oversized Load/Hauling Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and Is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale applicallon accepted: Date application expires: Application taken y.• (initials) BUILDING OWNER OR A(/IZED AGENT: Signature: j ‘ ,." 16 ._—' Date: y2 _ 2 - ,. 7 Print name:: S4G� e-86.-,-, Submit checklist , No: M -1 PI 323 Silo .- 7 /z 6/e/7 Address: y>7 /9v) e / 7 'mac �� City /State /Zip: L-N N N 1 0C aiA igd 774 0 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade. exceeding.5,000 gallons and ratio of height to diameter or• width . which exceeds 2 :1 PERMIT REVIEW Submit checklist . No M -9 ® Antennas /Satellite :Dishes Submit checklist , No: M -1 0 Awnings /Canopies - No signage Commercial Tenant Improvement Permit 0 Bulkhead /Dock Submit checklist No: M -10 Commercial.Reroof Submit checklist. No: M -6 Demolition.. Submit: checklist No : M -3, ■-3a Fences - Over 6 feet in Height Submit checklist No: M -9 Land Altering /Grading /Preloads. Submit checklist . No: M -2 71 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 s Mechanical (Residential& Commercial) Submit checklist No M -8, Residential only - H -6, H -16 Miscellaneous Public Works Permits Submit checklist No H -9 0 Manufactured Housing (RED INSIGNIA ONLY). Submit checklist No: M -5 Moving Oversized Load /Hauling Submit checklist No M -5' Parking Lots Submitchecklist No: M -4 Residential Reroof - : Exempt with following exception: If roof structure to be.repaired or replaced Residential Building Permit Submit checklist No: M -6 O Retaining Walls - Over 4 feet in height Submit checklist No M -1 Temporary Facilities Submit checklist No: M -7 Temporary. Pedestrian Protection /Exit Systems . , Submit checklist No M -4 Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS P • IT APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: > ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED D ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the propertyowner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 CITY OF TUKWILA Address: 14620 PACIFIC HY Sui te' Tenant CHEVRON. Status: ISSUED Type: O -MECH• Applied: 12/02/1997 Parcel #: 004000- .09.10 Issued:. 12/29/1997 **. A* kk.k; A• k• k• k*k- k' A'***• k k k'. k' kk• kk kk k*• k•*• k• k• k**• N• k• k**A• k .' k•* kk• k• k* k •k*•k**k•kkkk * *k Permit: Conditions: 1. No changes wi11 be made to. the plans unless approved by the. Arch 1 tect or Engineer and the -Jukwi la Building Di vis ion. Al l permi.ts, inspection moor { ds,' approved plans shat i : be available at the .o ,":; "s1te to the`' start of,. any con- struction. Thera `'document.s are to be maintaiheci and ava i - a b l e . ; • u n t i 1 final • ;nspeatibn approval, is granted. . All constructjon to be done' in conformance with approved plans. ,r..equ i r , .of the . Uniform Bull di rig Code (1994 Edieion) a'a; ; Uniform' Mechanical ..Code ` and Washington State Energy,,. Code, (1994 Edition) Val i di 014 if Permit The i.ssuanCe of a permit` •or'approval of plans,1Apecificatiar`is, 39,0. 'e6mputations shall not be - :' struedto be • a permit for, or an approval of, any violation of any of tihe,: prtiv i s ions of the bin i 1 d i n g code or of any other, of the No permit pre uming to . give authority violate or cancel the prov is ions of this code shall be <va l i d .` Permi t No:. M97 -0179 MAN IF iCTURER.: a I N.:, TALLATI 'ON ; . • INSTRucrION,,:REOUIRED ON SITE, .. FO =THE, OUI;�CrING INSPFCTOW REVIEW Eieuttrical .permi Shall be,obtain thro.ug,h the Washington S t 014/:. 06' of JLabc�r�; and :;Irt�iustri:es and al.l electrical' work i 1 `b'e 14nspe.c,,ted by ,..that. agency.`(24t -6630) . ACTIVITY NUMBER M97 -0179 PROJECT NAME CHEVRON DE TMENT: B ' G DIVISION I rah , PUBLIC WORKS L- DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE COMMENTS +r CrdCpy PLAN REVIEW / ROUTING SLIP FIRE PREVENTION bJ ❑ NOT COMPLETE ❑ TUES /THT RS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED ❑ ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS ❑. NOT APPROVED (attach comments) El REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED ❑ REVIEWERS INITIAL C:ROUTE -F DATE DATE DATE P ING DIVISION ❑ (c)r r't —6 11 PERMIT COORDINATOR DATE 12/2/97 DUE DATE 12/4/97 NOT APPLICABLE ❑ DUE DATE 12/18/97 DUE DATE APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Ceitificadon of occupancy required. ) 4 *s1 *si*sL ** *s4 * * F"k *p si *s1•h *A•tAlsnnis4•* *s%A *.% *dr * * * *•a+1•Ir*A*dit4,4 0 * *A•hh•1'* ITY. (F. TUKWILA., •,Wr1' . • m ' 7 Q TRANSMIT A *•Ak,k4c*s4ik.o. s1 •A.A ** * *:A*sA* * *•h•h* A *A*.AA * *s1A *% ** *A * *11�I * *h* *AAA. TRANSMYT., Numh'erl 89700697 Amount: 98.94 12/29/97 11::10 Payment 'Method: CHECK ,Nc;tat1an: POLAR S1 Aft .._._.._ , In it: K,7P_ Permit Not M97- -0179 Type: B MECH MECHANICAL PERMIT Parcel .Nai 004000• -0910 Site Addressd 14620 PACIFIC HY � i Total .Fecb: 98,.94 lilts Payment 9£1.94 Total ALL Pmta: 903.94 [4alance: .00 ****** A***** A*• A A * A ****** AA*• A*• h*• A* 1 **k. *A* * * *A* **A * * • 1r � * *A*Ara *A•** ** AIAot.lIn t 1.9.79 79.15 Acc'uunt Code 000/345.820 000/322.100 Ike €c:r i pt i on .PLAN CHECK AtiMRES MECHANICAL •- NOARE.,"a CITY OF T(JKWILA "°RECEIPT PW DCD 19.79 PW DCD 79.15 CHECK 98.94 12/30/97 17 16 :46 0097 7202 Project. „Tkei Type of inspeM4 /..Thei2 Address: / Date called: Special instructions: Date wanted: . el Requester: Phone No.: Inspector: I I INSPECTION RECORD Retain a copy with perm( INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Li Corrections required prior to approval. COMMENTS: $42.00 REINSPECTION F E REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Date: / n7 -0177 PERMIT NO. (206) 431 -3670 Project: 6 Minsj1gCro7i: Date called: Address /4/6 20 Special instructions: ' / --- l/G / S4 (,i-e- ,/ Date wanted: 3 3/ 79 p .m. Requester: Phone No.: k2/ COMMENTS: L n6Pt INSPECTION NO. I Receipt No.: INSPECTION RECORD Retain a copy with per g7--e,9/7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6� Approved per applicable codes. F1 Corrections required prior to approval. $42.00 REINSPECTION' FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 6300 Southcenter Blvd., #100, Tukwila, WA 981�r ,/ ,/ 206) 431 -3670 Date 7 3 / rg I Date: Project: V Type of inspection: Address: it Ir Date called: Special instructions: T r • Date wanted: '"4 -1g a.m. COD Requester: Phone No.: tOto - r i C' - 1 115i INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: Inspector: [receipt No.: INSPECTION RECORD Retain a copy with perm I J PERMIT NO. (206) 431 -3670 Corrections requ prior to approval. Date: .011. Ado $42.00 REINSPECTI •� F EE - EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: - WWet-- 14 egzo P-';' / " ccelgaussck A(41 ...., ., , Ai 2 - 9 V‘i> ' -S<C A !A il.c 6 `.. "g" thg F'kk a LS ' rt.) Gq)L,11■\C) (3 C" 0. AAR- s-cmgz pr-' tA NHIS I ' — r r.4 c-owo,..-2-44.:%-a._ F41._. I oF mii-ctil4q ' — Pai4VIac 4 L Ews-r- /6 ' sv. Ki MM-4 c.-'c 1zr F-A-N1 A14_0 N-J h.c- ttsrrik-gi L) Sp - iza-r4s...% ie-t Date wanted: j ... LI_ 78 Casr P.m. Requester: 3C 60 Phone No.: No.: 2 L., -N 2_ 8C1L4 L.) ° Project:eA Type of inspectibry ' a 1 ...-- ... A i / A tc, Nevni Li Address: Date called: Special instructions: Date wanted: j ... LI_ 78 Casr P.m. Requester: 3C 60 Phone No.: No.: 2 L., -N 2_ 8C1L4 L.) ° CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION NO. Approved per applicable codes. Inspector Receipt No.: INSPECTION RECORD Retain a copy with per Date: Mc-cl-ot - 79 Date: 4 q` PERMIT NO. (206) 431-3670 Corrections required prior to approval. I $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 PaU)W I !'1i1L�, TYp .4 i. y Adclk�s1 (.) at H,) L instructions:. c•Iled: Date wanted: r _ � _� rj ....076.C1 � j .. , m. Special ) Requester: (/'� P v edl9.: ! 510 — 7 5./ INSPECTION NO. CITY 'OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: c/Lez Inspector: INSPECTION RECORD ,�-- Retain a copy'with perml 1!' $42.00 REINSPECTI • FEE REQUIRED. be paid at 6300 Southcenter Blvd., Suite 100. Date: vrom vosata PERMIT NO. •. (206) 431 -3670 ,Corrections required prior to approval. ,/° tom -// f / � � r. 1 Dater — 7 ���� Prior to inspection, fee must Call to schedule reinspection. Receipt No.: '.,„4 , c Y•., 4,4; „. . tyt' Ht' :jrY >f*i'.��4'Y.'•: +.:i12`t+' °r "4"4r "� :.�r��.y+�wi 4t+ a�vo•�a :`.'uS':� ruw:y..r ..n.tt... r..._,. ,'��.. • City of Tukwila Fire Department Project Name C Address / P/9 • H y Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Ah Needs shift inspection Approved without correction notice Approved with correction notice issued Authorized -- Signature FINALAPP.FRM i T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. V -0/7 Suite # e a/ /; // te Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 PROJECT: DATE: 11/24/97 rialYORIC Heating and Air Conditioning SUBMITTAL DATA FOR: Quotation TUKWILA CHEVRON, POLAR STAR PURCHASER: POLAR STAR REFRIGERATION LYNNWOOD, WA PO NO: SUBMITTED BY: FAMILIAN NW / HVAC TUKWILA, WA c,yC� 4V.Dt \ C PERMIT CENTER M'tioi pEt1't \991 PIG ON \SVC3‘ r� �uV I yu CITYt�WILA DEC 021997 -10 1 v onK4autAr- Mole Opening Die. Use —' A 718" KO Control Side or Bottom Side or Bottom 8 2" KO Power C 1l? NPTI Get Front D _ 1 -112" KO Boa bin • NOV-24 -1997 11:20 WAS pwdNorie POLAR STAR Job Name Architect Engineer Purchaser POLAR STAR REFG. Submits(' ey FAMILIAN NW HVAC QUANTITY: 1 UNITS DESIGNATION:achedule No: CooLIN G1ERFOR � Total Capacity 83.0 MBH Sensible Capacity 46.0 MBH Efficiency (et ARI) 10.1 SEER Outdoor DB Temp 95.0 Entering DB Temp 80.0 Entering WB Temp 87.0 Leaving DB Temp 58.7 Leaving WB Temp 57.0 Power Input (w /o blower) 5.20 Elevation 0 i PERFORMANCE Gas Fired Input 0 Sea Level 100 Gas Fired Output a Sea Level 79 AFUE 80.5 SUPPLY AIR BLOWER PERFORMANCE Total Supply Air Outside Air External Static Pressure Duct Connection Location Blower Speed Motor Rating Power Input Requirement FAMI LIAN HVAC F F F F F KW Ft MBH MBH 96 2000 CFM 0 CFM 0.43 I WG Bottom High 1.0 HP 0.98 KW ELECTRICAL DATA - Power Supply 208.3 -6r Total Unit Ampacity 29.8 Amps Maximum Overcurrent Device Fuse Size 45 Amps HACR Circuit Breaker 45 Amps Minimum re Size 10 AWG (60 CL DIME • 1 •WIGHT Height 33 in Width 52 in Depth 45 In Total Weight (inci factory options) 720 Lbe V Front 32 In Back 36 in Bottom 1 0 in Top 72 in Left Side (fitter access) 36 in Right Side (outdoor coil) 24 In 1. Unlit my be Interned on oombusllble loon made ham woad melees A. It or c real Mewing melefisls. 2. Units must M Insl o4 out d us. Owuhe loIn o sbuduom or minas *WNW net ouumi t eondamer sir disallow west Ldoab the unit so Wirt or veil hood DOW is ss Not - 31est ikon any bread air inlet loomed wimin 10 hodmwndl Wit (a.oludby Dieu bMSpnl b Ws unit), • 4 No bulow, 4 hmbmibAl test horn, or 1 No mbave any Dow or aloft rol 9e Wet to No ioaosoe, euwoot le molar* mom • Ween t and MIlq UI • L SUNLINE 2000 TN GAS /ELECTRIC ROOFTOP UNIT all. PVC 1IDWALS MIND. DMIN Me Dodd •A1 114AdAthUID LOOATIOti inmae ',PRY • 11(TUNi Ave S • poWel WIMW army A • =MM. men B411W A 1 In. element* mat be padded buwdenl soy oombuubi• melmiel end the supply iii sumdeI bra Oieor co cf lset horn Ms WIlL The product ot ambuetlon roust net be ,itMd 10 eocumulw within a oreWm d pea and neituldle• Arrows. wYwt neasa -Mrieeb Wog •4404/ LYNNWOOD, WA. TUKWILA, WA. 0041110E FILTER RETURN AIR ° w1m SUPPLY AIR NO CONDENSER AIR [ OUTDOOR AIR —, (Emoaobri ID•SUPPUED SCOHNECT SWITCH Model No: D6CG060N07926EC AWNS UUOUNTWO BRACKET P011 DISCONNECT SWITCH 206 575 7887 P.01/02 Date 11/24/97 Pagel Order No VINT MN =1ST MUW as ss+;r ENTRY Utifitie• entry Date 001400111121 oDm.�lra.tst MUTKorn OAS Hilt o A� OW SUPPLY n om tiu 15414 UNIT SAi3Ti WITh RAIL$ mr $rerarty r webs. p- a e NM: .iet wlbnw %.lb. /Ow to the dual brio dlwa.Wwd 10 Ike sorb andd n w pow elm . MI ..= ACCESS • • NOV-24 -1997 11:20 IC hM.ag.nd Pa Cordially - Ambient Modified - TIms/Tsmpenatur. Defrost Logic on Hest mps RAL FEA - Hih & Law Pressure / Loss of Charge and Freerstat Protection Switches - Capper Tubs/Aluminum Fin Colts • Easy Access to ale Electrical Components - Rigging Holes and Fardit clot. in Base Rails for Lining - Single Point Power Connection - Powder Paint Finish That Meets ASTM -0117, 750 hr. Salt Spray Ted Standard. -AgemyAPf - UL B CG.A on All Units - Factory Warranty - One Year on the Compiet. Unit - Four Addition., Yearn on the Compressor - Four Additional Years on the Electric Heating Elements • Nine Additional Veers on the Gas Fired Heat Exchanger FACTORY INSTALLED OPTIONf •, ECONOMIZER Wl SINGLE INPUT ENTHALPY CONTROL ECONOMIZER •/ DUAL INPUT ENTHALPY CONTROL BELT DRIVE INDOOR FAN TechniCoat CONDENSER COIL OPTION - Complete Factory Paddies - Teeted, Chemed, Wired • Hsn lelaMry Sealed Compressor - Direct Drlw or fees Drive Motor Options - Unit Underside Insulted - Spark Wilton • Induced Draft with Poet Purge Logic on Gas Fired Units - Bottom or Side Duct ConApuredon capability - Low Wage Raley Board With Termini Strip • PTC Type Crankcase Hadar • Liquid Una Fier Drier • Pk,•Type Wiring Harness Connectors for Economizers • Permanently Lubricstsd Motors • 24 Vol Control Circuit with compressor lock ow protection • M.nufacttlrad Under the Quality Standards of ISO 2002 - Ace's-Sena Changeover Cantu)! for Mrodmun Heating Comfort between Gad & Had Pump Opunslkin an Dual Fuel Units FIELD INSTALLED ACCESSORIES START ASSIST KIT (Single Phase Units) OUTDOOR THERMOSTAT ANTI-RECYCLE TIMER MOTORIZED OUTDOOR AIR DAMPER 0 Dig, LOW AMBIENT CONTROLS ECONOMIZER w/ SINGLE INPUT ENTHALPY ECONOMIZER Wl DUAL INPUT ENTHALPY CONTROL 4 ROOF CURB REUEF / FIXED AIR DAMPER OUTDOOR COIL GUARD BURGLAR BARS PROPANE CONVERSION KIT LOW NOx KIT HIGH ALTITUDE NATURAL GAS HIGH ALTITUDE PROPANE GAS PIPING KIT Nettie: THERMOSTAT FAMILIAN HVAC SUNLINE 200dM GAS/ELECTRIC ROOFTOP UNIT D6CGOSOND7825EC ,7 -we REAR VIEW SIDE SUPPLY AND RETURN AIR DUCT OPENINGS 206 575 7887 P.02/02 Date 11/24/97 Page 1 Order No n 4 Inchoate() a eeleoted option or accessory UNITS WITH ECONOMIZER RAIN HOOD do FIXED OUTDOOR DAMPER HOOD 'so 9002 TOTAL P.02 Vertical Discharge . entrifugal Ventilators ltES .pail Aluminum l lousing tuc:al Discharge kited Motor Compartment t;aiuunt Wheel ;tri;ible Pitch Drive Licensed '.;';'!.!CATION - Attractive, low profile _ .. ;,rititeal vertical discharge belt drive ,:; are intended to move large ant of air efficiently, quietly and ununuously at moderate to reasonably high cnai pressures. They are especially ;'commended for over cooking and fume :.,;);1 exhaust systems where the air must be . rig: rued vertically. :... i. - i'tecision balanced backward L) erloadina aluminum ■vheels ;'• .t .lac r. orifice for high efficiency. - z T V E :_'helsea" Fans & Blowers _ 00 Falahee Road Y.O. Box 767 i nckson, MI 49204 -0767 .1;-764-6200 Fax 517 -764 -3838 V Y Z C E A B Curb Opening A Sq. -- • 9.25 24 29 23 26.75 .: 28,75 22,50 22.50 30.50 30.50 PAC22.5-8 PAC22,5.8 16.50 16.50 9.25 24 29 23 7: rl HOUSING - Spun aluminum housings incorporate a true venturi orifice to guide the air into the wheel with a minimum loss and turbulence. A vertical discharge skirt maintains weatherproof integrity. • w wj.l I ..hi .. GENERAL - The`simplicity.of their design makes every portion of the Chelsea CUBA readily accessible for periodic examination. Fiberglass 1'/a" Thick 84 Density 1+-: Curb .I • Opening E--- --- 8q MOTORS AND DRIVES - Standard NEMA frame ball bearing motors are isolated from the airstream and housed in a weatherproof enclosure, equipped with breather tubes, which permit clean outside cooling air to circulate around the motor for maximum life. The entire wheel and motor assembly is isolated from the rest of the unit. All units are'equipped with ball bearings and a variable pitch pulley to allow field adjustments to the fan RPM. 1 -).! F 8 " if: FORM NO. 4535 EFFECTIVE AUGUST 15. 1994 OPTIONAL ACCESSORIES 8 30 31 29 31.50 28.50 36.50 PAC28.5-8 22.50 • Back Draft Dampers • Epoxy Coating CITY OF TUKWILA • Prefabricated Curbs • Disconnect Switch DEC it Z 1997 • Bird Screen QITICQ CERTIFIED RRTIROS wa w RIR movsmlm AMOCO/IMO,. Assocunnon. me 10.50 36 42 35 34.50 34.50 42.50 PAC34.5.8 28.50 . TYPE CUBA EF - 3 RECEIVED PERMIT CENTER Chelsea certifies that the CUBA - Centrifugal Verti.:ai Discharge Dome Exhausters shorn herein is licensed to bear the MICA seal. The ratings arc based on tests and procedures performed in accordance with AMCA Publication 211 and contp■ with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to Air MODEL ` CUBAl22 ;CUBA165 CUBA200 CUBA245 CUBA300 CUBA365 2.75 42 48 41 35.50 40.50 48.50 PAC40.5.8 34.50 4.50 48 55 47 37.75 46.50 54.50 PAC46.5.8 40.50 Model CUBAl22BA CUBAl22BA CUBAl22BA CUBAl22BA CUBAl22BA CUBAl22CA CUBAl22CA CUBAl22CA CUBAl22DA CUBAl22DA CUBA165BA CUBA165BA CUBA165CA CUBAI 65CA CUBA165DA CUBA165DA CUBA165FA CUBA165FA CUBA16511A CUBA! 65HA HP 1/6 1/6 1/6 1/6 1/6 1/4 1/4 1/4 1/3 1/3 1/6 1/6 1/4 1/4 1/3 1/3 1/2 1/2 3/4 3/4 RPM S eed 750 2405 950 3047 980 3143 1150 ; 3689 1320 !. 4234 1365 14378 1430 /4587 15501 4§72 1680 5389 600 2592 830 3586 855 3694 Motor Fan Tip Max CU IA P BHP 0.03 0.07 0.07 0.12 0.18 0.20 0.23 0.26 0.29 0.37 0.07 0.18 0.20 0.31 0.37 2351 2210 960 4147 1802 990 4277 1882 1060 4579 2060 1095 4731 2150 l'ormance CA PACITY - CFA1 "S.P. 1/4" 3/8" 1/2" 5/8" 3/4" 1" 1 1/4" 1 1/2" 362 705 515 749 575 960 840 700 470 1168 1078 962 840 678 1220 1130 •102.' 910 774 1291 1208 •11i. '1010 911 1370 1290 • 1216 1111 1005 715 1425 .1350 1272' ' 1180 1085 830 1570 1500 1430 1355 1268 1080 810 740 1460 1530 1250 970 1345 1075 180 1630 1445 1220 570 1713 1542 1338 1038 1900 1745 1575 1368 1998 1845 1688 1505 405 2303 2160 2021 1879 1520 260 2400 2270 2140 2000 1690 1100 2756 2630 2508 2390 2140 1844 1380 drive losses. • • Centrifugal Dome Exhausters FEATURES • Spun Aluminum Housing • Over - lapping Wheel Orifice . Full Floating Rubber Vibration isolators • External Wiring Conduit ▪ •lentilated Motor Compartment - !;iurriuturri Wheel • r3ird Screen - AMCA Licensed APPLICATION-- Attractive direct and belt ce•ntr,tugal dome e><huusters featuring • res.stant cow:AR c r. in lo'A' sdhou- rinCU tree designs, are ideally nualS. hr,iat c-s hospitals, institu- rat.:aratones. offices or any ventilating tern ,.here ultra - quiet, high capacity air • ,:errier,t is required at moderate static ,.lessors WHEELS - Precision balanced, all alurni- r: non - sparking centrifugal wheels, posf- y rocked to the drive shaft, incorporate erlr.ading, backwardly inclined blades rrauped Data,& design' for maximum lip speed TORS Alit) DRIVES - `.:;,.,,iusia are rurcu'; e lne air ....•, J. ';1 rH.u;:.ed,ri 6 :,e;itncr•oiuot enclo- ... • c e ;y., t:; ea with protected louvers, permit air to circulate around the motor et :iuc; it ventilated lot maximum service life. r r,tre whcet and muter assembly is also also Irorn the rest of the unit on rubber vr- b: i oarrpeners • tr ,e ; nodeis are equipped with non•can- ilairge mounted ball bearings rest. n„r;: anlal supports, plus a variable . ' r.,.Iie, to permit minor field adjustments. HOUSING - Spun aluminum housings incor- .. •- rate a true ventun orifice to guide the air i lns'Nrieel witn minimum loss and tur- rr •41 aluminum inum weatherband sum- wheel inlet to prevent the entry of ,. s.a:,w:,n rain arid snow. In addition the non - t,; ;rnct.ve design limits the number of direc- tional changes in the air flow pattern, thus further reducing turbulence and air move- ment noise. To facilitate easy wiring and also arotecl the power cable as it passes through vrneei compartment, an external conduit ro, idea as standard equipment. GENERAL Tne simplicity of their design e.er; portion of these dome ex- saris ream!; accessible for periodic "10•" wheel and larger NON - RESTRICTIVE HOUSING A unique, nonrestrictive • wheel and housing ar- •rangemenl number of limits directional the ..: ;.,changes in the air flow pattern. Large v of air, pulled up through a true.venturi orifice, glide off the wheel in a straight line and gently arc out along the deflector dome. This straightening of the air flow, reduces pressure loss within the housing, cuts turbulence and air move- ment noise to a minimum, increases air deliv- ery al static pressures, and results in higher overall efficiency. OVERLAPPED ORIFICE Most competitive ex- hausters are equipped with so called "flat" wheels which approach the inlet orifice butt fash- ion. We use an all aluminum, non - sparking wheel (10" dia. and larger) which in addition to its non - overloading characteristics incor- porates a contoured front plate which signifi- cantly overlaps the inlet orifice, thereby eliminating inlet losses which in turn, in- creases efficiency and results in lower tip speed for any given CFM. PROTECTED DISCHARGE An alumlii'tirn weather- '• band surrounding the :wheel inlet sets up a pro- tective labyrinth to pre- vent the entry of windblown rain and snow into the ventilation system. Further, any moisture trapped within the labyrinth is automatically discharged back onto the roof, thereby eliminating corro- sive water pockets. This feature when coup- led with standard bird screening provides a protected chamber for the ;Centrifugal wheel, assuring safety and freedom from contamina- tion by foreign objects. 7 Ku,..., 1 TYPE RDD RDB ACCESSORIES PREFABRICATED CURBS Factory. asembled and coordutalco for fan size, the curbs feature a built-Ii cant lu; easy flashing and installation HINGED CURB ADAPTER — Allows ea:.; access to interior of curb. BACK DRAFT DAMPERS — Either aura matic or motorized back draft dampers are available. DISCONNECT SWITCHES -- Otsccnnec; switches are available for most standard units. HEAT SHIELD -- For high heat ser.ine ditions such as dishwashers. range f r,.ucl , etc . a therrnalty insulated neat s ,,:,.. ;_•r provided to insulate the motor drive uuil.a :r. merit against damaging heat Iran is; c,;,s t.r. from below. Normally this is used with a snr,i• seal to further isolate and protect lrle i.e compartment. SHAFT SEAL— Used in conlunctior ;, ii, heat shield, to completely isolate me nick,/ compartment from heat transmission Iron h.. low and/or to provide a gas protected nnistor compartment. Use heat shield and strait bin, when temperature of air through fan is over 140 °F. Contact factory for special nigh toil. perature motors for air over 160'F. PROTECTIVE COATING - -- Epcote coatings provide good protection against most corrosive agents: 0 Effective January 18, 1995 Catalog 4259 -C G.F.- ► 4 2,, Chelsea certifies that the ROB aria ADD-- - Centrifugal Dome Exhausters shown hereof are licensed to bear the AMCA Seal The ratings shown are based on tests aria procedures performed in accordance win AMCA Publication 211 and comply with tie requirements of the AMCA Certified haw ige Program. The AMCA Certified Ratings Seal appite:t: Air Performance Ratings only . entrifugal t Dome Exhausters ..;ry t NSJ0NS eL: ADD --- DIRECT DRIVE 19'ie 20 10:1/44 20 Aboi0k. . 19'2 20'/2 10 20 10 1/2 20'/T 10 20 i 'oi.. 19 20'2 14 26 '/4 19 20'/2 16 26'/4 i'Ja 21 22 19 31 3 /s 151) 21 22 19 31 ru5 21 22 20% 31 .. ,t . i....wr..vuts •11.rwn 4a1 aplwoalmeta, Certtnod prints available. ErtUti - DELTDRIVE 2:. 21 195 28 200 28 235 30 .JJ 36 41 DRIVE Molar ..... .:I rit,. HP r,uUiJYU '' ,.19060Y9 TUYU '2: :ID95UXti 'Its lluuiU ZC :i0U1U5CAV riL111U5CA rit)U 122AC 1200 1220AV ui U 12YUA UU135bCY :100135FAV 1100135FA HOD150CCV itUU165FC V' Roof C Y V• Z' Open. Max.t 22 20% 30 12 29 241 35 19 29 26% 411 19 31'4, 293 45% 211/2 37 35% 52% 27 42 37% 60 32 ' 54 413'9 67 V.1 44 air Cole ten:01. a.;WaLa, Fan Max, RPM BHP 0" 1550 .028 387 1550 .045 475 1550 .090 800 'n2 1150 .06 857 1625 .17 1210 1725 .20 1285 1 10 1150 .10 1250 1625 .30 1785 1725 .36 1880 1 12 1075 .14 1661 '/2 1625 .49 2511 1 /2 1725 .59 2667 '/4 1075 .24 2279 It 1150 .48 2870 Roof Z• Open. Max.t 10 10 10 10 10 12 12 12 Inside Dim. Mln. 121/2 121/2 12'/2 12 12 14 .. 14 14 Cat. Damper Size BD20 BD20 BD20 BD20 BD20 BD22 13022 Inside Cat. Dim. , Damper Min. Size 14 8022 21 ,u ;':'1 ` B029 21 B029 23 BD31 29 BD37 34 8042 46 BD54 Capacity (CFM) at "SP Actual Damper Size 12 12 12 12 12 13 13 131 Actual Damper Size 13'/2 20'/2 20 23 281'2 33 45 TYPE RDD RDB RDD NOTE: Olmen1lons shown are approximate. Combed pants available. RDB 'V and Z may vary with typo o1 motor osed - smalloal shown. Maximum opening Thal allows root lobe used as camper m.pput F.A. Sones (a 5' App1U4 Field Ship. VC I/4 3/ " 1 /x" kg" 3 /4 0 1.8 Curb PAC Wt 284 208 1.9 1.7 21 367 300 225 2.6 2.3 21 660 502 • 419 374 ' 175 3.7 3.3 24 775 685 570 375 3.0 2 7 39 1155 1096 1030 986 922 823 533 4.4 4.1 1230 1175 1120 1055 990 915 725 5.1 4.6 45 1144 1054 923 763 338 4.2 3.8 48 1708 1632 1555 • 1473 1390 1302 1092 6.3 5.7 1827 1758. 1688 . 1618 1527 1442 1268 7.2 6.5 5U 1550 1423 ` 1282 ' 1087 725 5.1 4.6 64 2440 2355, w„t .2275'i2192 • 2075 2020 1915 8.6 7.7 2584 2507:•':.$ 'r 2433 t.2371 2282 2208 2051 9.9 8.9 67 2145 .2008` •.A.r1867 '01715 1403 1150 5.9 5.4 70 2741 2612 I - 2329 2166 1996 1374 8.7 7.8 83 Shown is norninel, performance is based on actual speed of test. All capacities listed are based on Standard Air Density 0.075 LBS. /CU. FT. (70•F & 0 FT. elevation) a ai,vr n is for installation type A•Free Inlet, Freo outlet. Performance Ratings Include the effects of Bird Screen In the airstream. 2 9 9 7 1 10t17 HIGH & MEDIUM TEMPERATURE ELECTRICAL DATA SDA ONLY 8 FIN PER INCH MODELS 090H --.±-114$:108H 119H Model Size 054H 066H 074H 139H 171H 201H 230H 270H 330H 410H 049M 060tv1 085M 105M 124M 150M 170M 210M 254M 305M 350M 036M 050M 080M 102M 125M 168M 214M 255M 325M 2.0 2.0 2.0 4,0 4.0 4.0 4.0 6.0 6.0 6.0 8.0 10.0 12.0 2.0 2.0 4.0 4.0 4,0 6.0 6.0 6.0 8.0 2.0 2.0 4.0 4.0 6.0 6.0 8,0 10.0 12.0 FROM ,f' ..V N14F210ER', 1.0 1.0 1.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 4.0 5.0 6.0 1.0 1.0 2.0 2.0 2.0 3.0 3.0 3.0 4.0 10.0 5.0 12.0 6.0 1.0 1.0 2.0 2.0 3.0 3.0 4.0 5.0 6.0 Motor Data t Z 460V 1 Ph 0.5 0.5 0.5 1.5 2.0 2.5 3.0 0.5 0.5 1,0 1.0 1,0 1.5 1.5 1.5 2.0 2.6 3.0 0.5 0.5 1.0 1.0 1.5 1.5 2.0 2.5 3.0 t Standara motors: 1%20 HIS, 1550 Rt�M, SHacl d -po{a SDA and SDG only 50 Hertz Applications: 208 -230 volt unit$ are suitable for 50 Hz voltage from 187 -220. •• Contact factory if jobsite voltage is Total Watts 140 140 140 280 280 ; 280 '420 420 420 560 700 840 •. 14 140 280 280 200 420 420 420 560 700 840 +: . Ara '1111'! r0 POLY: STAR REF: F'. +1 208 - 230V 1 Ph ':PDA- SDE -SDG 'SDA-SDE -SDG 6 FIN PEH 1 CH MODELS 4 FIN PCR INCA lv QL)E.L;; 140 140 280 280 420 420 560 700 840 4.6 4.6 8.2 8.2 11.9 13.8 15.5 19.2 22.8 2.3 2.3 4.1 4.1 6.0 6.9 7.8 9.6 11.4 1047 1047 1887 1887 2727 3171 3567 4407 5850 • • . r •';,- 77T !fir tip'4 -:: 'F�?''T 4,6 4.6 9.2 9.2 9.2 11.9 11.9 13.8 15.5 19.2 22.8 Defrost Data -- SDE Only Amps 460V 1 Ph 2.3 2.3 4.6 4.6 4.6 6.0 6.0 6.9 7.8 11.4 Total Watts 1047 1047 2085 2085 2085 2727 2727 3171 3567 9.6 4407 5850 TUKWILA ' I DEC 0 21997 PERMIT CENTER 7 ' SDE -SDG Mode! Size Capacity STUN -20' 10 S.T. 6 FIN PER Fan Data• INCH MODELS , "' " ` Dimensional Data Approx. Ref Chg. Lbs. R -22 Appro� :. Ship Weight CFM No. Faris (12 Dla:� . ; . , .L ength Liquid Conn. O.D. Suction Conn. O.D. 052L 036L 3600 815 1 ;`,,,, 26 1/2 1/2 7/8 1.5 53 1/2 046L 4600 815 1 261/2 1/2 7/8 2.1 56 3.8 055L 5500 1670 2 431/2 1/2 7/8 1.9 78 114 065L 6500 1720 2 471/2 1/2 7/8 2.1 80 18100 078L 7800 1630 2 431/2 1/2 7/8 2.9 80 Is 089L 8900 1690 2 : 471/2 1/2 7/8 3.2 69 1111/2 120L 12000 1690 2., ,;t ;; 47 1/2 1/2 7/8 4.3 I 92 135L 13500 2580 l. ii' ( P''''' 6 1/2 1 1/8 4.4 125 160L 16000 2445. ; 34 t , kt � . 1/2 t' 1/2 1 1/8 5.6 124 180L 18000 2580 3`w ". 69 1/2 1/2 1 1/8 6.6 137 215L 21500 3260 4'''` " ' 77 1/2 1/2 1 1 /8 7.4 156 240L 24000 4075 5 941/2 7/8 11/8 9.2 193 265L 26500 4890 6 1111/2 1/2 11/8 8.3 220 300L 30000 4890 6 1111/2 7'8 11/8 11.0 228 SDE -SDG z C r-rc�i H INCH MODELS 040L 4000 825 261/2 1/2 7/8 2.1 56 052L 5200 810 , 261/2 1/2 7/8 2.6 58 075L 7500 1650 431/2 1/2 7/8 2.9 83 088E 8800 1650 2 431/2 1/2 7/8 3.8 88 110E 11000 2475 3 601/2 1/2 7/6 4.2 114 140L 14000 2475 3 601/2 1/2 11/8 5.6 120 181L 18100 3300 4 77 1/2 1/2 1 1/8 7.4 155 220L 22000 4125 5 . 94.1/2 7/8 1 1/8 9.2 190 260L 26000 4950 6 1111/2 7/8 11/8 11.0 226 1 :o :.'1997 10:18 • FRi'Ii JERRY NAFZIGE 'ASALES. TO POLAR STAR REF: t Ordering Information All stock unit coolers are circuited for. operation from 9° to 12° TD. Special circuiting may be required for other TDs Please contaot factory. Please Specify: Model number Motor electrical — volts /hertz/phase Heater electrical — volts/phase Evaporator temperature -- °F Design TD or operating capacity Liquid temp. at TX valve (100 °F, is standard) Air Throw; Up to 30 feet based on 9' ceiling and no obstructions. LOW TEMPERATURE PERFORMANCE AND SPECIFICATIONS t P.02 itr ns /ona/ Notes; gter to page 8 (back cover) for complete dimensions. pth on all units Is•15 1/4 inches, iQht,on all electric defrost units is 15 1/2 inches. ;`Refer to page 8 for height on hot gas units. All units furnished with •1/4" 0.0. ext. equalizer connection, All units furnished with 3/4" FPT drain connection. All SOS units have 1/2" ODM hot gas connections. Refrigerants: PII stock units are suitable for R - 22, 404a, 502 & 507. emperature Correction Factors: X30° F. S.T. = 0.95 -10 F. S.T. = 1.04 0° F. S.T. = 1.06 ., 50 Hertz Applications: Divide the STUN requirement by 0.92, then select the unit cooler directly from the table above. See Page 5 for electrical requirements. - -;; Sq = Model Size { 6 FIN PER INCH Motor Data t MODELS Defrost Data - SDE Only ; _ Total A . , ---_• z •S 1 Total Watts 115V • r 208.230V 460V TOtB! Watts 208 - 230V 460V r 1 Ph 1 Pb 1 Ph • • 1 Ph 036L 2.0 0.5 140 4.6 2.3 1047 � 046L 1 2.0 1.0 0.5 140 4.6 2.3 1047 0551. L 4.0 2.0 1.0 280 8,2 4.1 1887 065L , 4.0 O O O coo coo NNN NC) CM 't!) l 1.0 280 9.2 4.6 2085 078L 4.0 1.0 280 8.2 4,1 1887 " 91. 4.0 1.0 280 9.2 4.6 2085 120L 4.0 1.0 280 9.2 4.6 2085 135L 6.0 1.5 .; . 420 13.8 6.9 3171 160L ( 6.0 1.5 ::' '420 11.9 6.0 2727 180L 6.0 1.5 $ "" �, „420'.. 13.8 6.9 3171 215L 8.0 2.0 ?'� _? 560 ' 15.5 7.8 3567 240L 10.0 2.5 s' ''700 19.2 9.6 4407 265L 12.0 6.0 3.0 840 22.8 11.4 5250 3001. 12.0 6.0 3.0 840 22.8 11.4 5250 • i'�: 19'37 10: 1R FRO19 JERRY HAFZIOERL''J• &`J ALES. TO POLAR STAR REF: �'• i� LOW TEMPERATURE ELECTRICAL DATA $DE•SDG 4 FIN PER INCH MODELS 040L 052L 075L 088L 1101, 140L 181L 220L 260L 2.0 2.0 4,0 40 6.0 6.0 8.0 10.0 12.0 1.0 1.0 2.0 2.0 3.0 3.0 4.0 5.0 6.0 0.5 0.5 1.0 1.0 1.5 1.5 2.0 2.5 3.0 140 140 280 280 420 420 560 700 840 t Standard motors: 1/20 HP, 1550 RPM, shaded-pole. Op tonal PSC motors are ailable -- •contact tactory. SGG only DEFROST TYPE A -Air E- �kCln6 G -Hot Gas ELECTRICALCODE' A- 115/1/60 0- 208.230/1/60 F- 460/1 /60 M TEMPERATURE APPLICATION H -Hlyh M- Medium L -Low 4.6 4.6 8.2 8,2 11.9 11.9 15.5 19.2 22.8 2.3 2.3 4.1 4.1 6.0 6.0 7.8 9.6 11.4 1047 1047 1887 1887 2727 2727 3567 4407 5250 50 HPr Applications .208 -230 volt units are suitable for 50 Hz vvltakie from 187.220. contact factory . ii jobsite voltage is beyond 1:hat raNe. 50 Hz. motor watts = 60 Hz. motor watts x 0.83. High Temperature Application Medium Low Dinien:oltis Mounting in Inches Slots F SOG t 9 FPI 6 FPI 4 FPI 6 FPI 4 FPI B C 0 1 E 054H 066H 074H 049M 060M 036M 050M 036L 046L 040L 052L air% .k ' 26 1/2 + �.s , 21 — 3 1/4 2 1/4 16 3.4 090H 108H 080M 102M 055L 078E 065E 089E 120E .075L;,, Q881 ?. :.,., , 110E . 140E "i`.p' _' '," il 2 ` 1g1;. , :' 4 /2; �' "J.' "i ' 1" "60 ,1!2 • 33 ' 41 50 1/2 -- —• — 6 3/4 41/4 6 1/2 3 3/4 2 1/4 3 112 16 3/4 17 17 119H 139H 085M 105M 124M 171H 201H 150M 170M 125M 160L 230H 210M 166M 135E 180E r 891%2 61 -- 5 3/4 2 3/4 17 270H 254M 214M 2151. 240L 181L 2201' 7z 1/2 94 172 67 1/2 84 1/2 33 3/4 33 3/4 6 1/2 6 1/2 3 1/2 3 1/2 17 1/4 17 1i4 330H 305M 255M 410H 350M 325M 265E 300E 260E 111 1/2 , .. ;.101 1/2 50 3i4 6 1/2 3 1/2 17 1/2 1 19 10:19 13 1:2 SOG ONLY RCN.i..w CiU I L 1:2 -.i 0 FROM JE /RY NPFZ113E SUCTION A LIQUID •" LINE OPENING DIMENSOIAL DATA TOP VIEW B FRONT VIEW A DRAIN TO POLP STAR REF: F'. 0 4 0 el OPTIONAL LONG THROW FAN GUARD 1/2.—J — \s p 13 7/16 MIN. RECOMMENDED MOUNTING MOUNTING F . { v TIM •`� I 7/8 2 i KNOCKOUTS TOP 3 7.4 (OPT.) 21; _ END VIEW ^—' -• 161.4 • 13 --} .�. ..c ••1 _..l NOTE: E ,t. ITCHED WITH ORA1r. CONNECTION CENTERED Ct'I Et.r t Low temperature SOG only has pitched drain pan. WITT • 435 Washington Street • P.O. Sox 580 • Collletviiie, TN 38027 • (90$)'853 -2770 • FAX 901 853.8622 Model Number 1 I Air ' 330 , 335 SEMI -HERME 1C UNITS PWS 00SH22 I 15 15 PWS 005L22 15 15 PWS 005L44 15 i 15 PWS 007H22 15 1 15 PW3 007M22 I 15 ; 15 PWS 007L22 15 15 PWS 007L44 15 15 PWS 0101122 15 17 r'W5 010L22 15 i 16 'WS 010L44 15 16 PWS 015H22 15 • 25 PWS 0151.44 l 15 25 PWS 020H22 15 ; 25 • PWS 020M44 15 25 PWS 020L22 21 27 N WS 020L44 21 27 — WS/NS 030H22 25 37 40 WS/NS 030M44 I 25 37 40 WS/NS 030L22 24 36 40 ■•1S/NS 030L44 24 36 • 40 wD/ND 030L22 38 I 48 48 v1D/ND 0301.44 36 48 48 WS/NS 040122 — — — WS/NS O40M44 — WD /ND 040122 — WD/ND 040L44 — WD/ND 050H22 ' — I WO/NO 050M44 — I — I — WD/ND 060L22 WD/ND 060L44 iEHMETIC UNITS eWH 005H22 PWH 005E44 -WH 007H22 :PWH 007M22 PWH 009E44 • 'WI1 0101122 PWH 010M22 PWH 012H22 PWH 015H22 '.VIH 015E44 i'WH 0201122 PWH 020E44 PWH 0251122 PWH 025E44 PWH 033E44 P'NH 0301.44 --- 1y.PWH 038144 WH/NH 030H22 `WHINM . 040422 WH/NH 040E44 WH/NH 0$0H22 WH/NH 050E44 12 10:20 15 15 15 15 15 16 15 16 15 19 15 16 15 I 20 15 16 16 25 16 25 19 25 16 25 24 18 25 18 20 32 42 33 46 42 FROM J iiRV NAFZIOER • :rt._- :9PZlt. 50 50 50 50 50 50 336 Air " 15 15 15 15 15 15 15 15 15 15 15 15 15 16 15 15 18 19 17 19 24 24 31 31 36 36 31 31 39 39 15 15 15 15 15 208- 2303/60 st Optlo Deft, Opt, 330 33$. _: r: 36 ' Air " 336 15 15 15 15 15 15 15 15 15 15 25 25 25 26 25 25 30 31 29 31 36 36 43 43 48 48 43 43 51 51 15 25 25 25 25 30 — — 17 25 25 — — 15 26 31 — — 16 25 25 — -- 15 25 26 — — 15 25 44 44 50 21 .33.' 54 54 Be 28 —' : 45 45 50 23 35 58 55 62 30 42 54 54 58 29 41 MOW VOA 4Q _ , 40 40 ao 40 40 43 4a 4!! 61 51 INSO Ws. 42 IMUM CIRCUIT AMPACITY 460/3/60 OMEN mow 41 50 L;E • • ;i rclu0es units ordered with no defrost option. See Pg. 11 fordsfrost option sp.ce. . 15 15 15 16 15 15 15 15 15 15 15 MEMO 15 15 15 26 25 25 25 25 60 15 25 50 15 25 50 15 25 60 15 25 50 15 25 50 16 25 .:50, . -16 26 .. 15 25 16 25 16 25 15 25 15 25 51 15 25 51 15 25 15 25 25 15 25 15 25 '•15 25 25 25 25 25 15 25 15 25 1.sirnmum circuit =pacify = 125% of the rated load amps 01 the I.rpest load In the circuit plus 1 Gc % of tho rated load amps of all other loads In the circuit. St y '' ' TO P01. STAR REF: Model Number Air' I SEMI-HERMETIC UNRS 44 I 61 44 61 WD/ND 0751122 46 63 WD/ND 075M44 46 63 WD/ND 0801122 46 I 63 WD/ND 080M44 46 ! 63 WD/ND 0851122 58 75 WD/ND 085M44 58 75 WD/ND 0751.22 46 63 WD/ND 0751.44 46 63 WD/ND 0901.22 55 72 WD/ND 090L44 55 72 WD/ND 1051122 61 78 WD/ND 105M44 61 78 WD/ND 1001.22 59 76 WD/ND 100L44 59 76 WD/ND 1051.22 63 80 WD/ND 1051.4a 63 80 WD/ND 120122 , 67 84 WO/ND 120M44 . 67 84 WD/ND 150M22 81 98 WD/ND 150M44 81 98 WD/ND 1501.22 72 89 WD/ND 1501.44 72 89 WD/ND 065L22 WD/ND 0651.44 WD/ND 1001.44 WD/ND 106L22 WD/ND 1051.44 WDIND 120M22 WD/ND 120M44 WD/ND 150M22 WD/ND 150M44 WD/ND 150122 WD/ND 1501.44 27 32 32 33 33 40 40 36 36 208- 230/3/60 Defrost Option 336 338 337 339 P.o 75 100 75 100 75 ` 100 75 i 100 75 100 75 100 75 100 i 75 100 75 100 75 100 75 100 75 i 100 78 ' 100 78 100 76 100 70 100 80 100 80 ' 100 04 100 84 100 98 • 100 1 98 100 89 100 89 100 480/3/60 Model Defrost Option Number 1 336 Air • f 338 ; 337 339 SEMI - HERMETIC UNITS WD/ND 0651.22 20 1 30 40 50 WD/ND 0651.44 20 { 30 40 i 50 WD/ND 0751122 21 31 40 50 WD/N0 075M44 21 31 40 i 50 WD/ND 080H22 21 31 40 50 WD/ND 080M44 21 31 40 50 ' WD/ND 0851122 28 38 40 50 • WO/ND 085M44 28 , 38 40 50 WD/ND 075122 23 . 33 40 . 50 I WD/ND 075144 23 33 40 50 WD/ND 090122 24 34 40 50 j WD/ND 090L44 24 34 40 50 i WD/ND 1051122 28 38 40 , 50 WD/ND 105M44 28 38 ; 40 50 , WD/ND 100L22 27 37 40 50 J 37 ? 40 50 42 42 { 50 42 42 50 43 43 I 50 43 43 50 50 r 50 50 50 50 50 46 i 46 50 46 ( 46 I 50 • 1 2 • 1 9 9 7 10: 21 hfodel ' Nom. Reirg. Number H.P. PWS 0051422 22 PWS 005L22 ' PWS 005L44 PWS 0071422 PWS 007M22 PWS 0071_22 PWS 007L44 PWS 010H22 -' 010122 }WS 0L44 1'WS 0151422 PWS 015L44 • PWS 0201422 PWS 020M44 PWS 0201.22 PWS 020L44 Model Number PWH 0051422 005844 PWH 007H22 PWH 007M22 PWH 009E442 PWH 0101422 PWH 010M22 PWH 0121422 PWH 0151422 PWH 015E44 PWH 0201422 PWH 020E44 PWH 0251422 PWH 025E44 PWH 033E44 PWH 030L44 PWH 038L44 WH/NH 0301422 WH/NH 040422 WH/NH 040E44 WH/NH 0501422 WH/NH 050E44 1/2 22 404A 22 3/4 22 22 404A 22 1 22 ' 404A 1 1/2 22 404A 22 2 1404A 22 404A 1/2 22 404A 22 3/4 22 :404A ' 1 ; 22 22 11/4 22 1 1/2 ; 22 404A 2 22 404A 21/2 22 404A 404A 3 404A 404A FROM JMRY NAF2IGER)**5 Recvr. Cap.' Lbs. Refrg. 6,6 6,6 5.7 6.6 6.6 6.6 5,7 6.6 6.6 5.7 11.5 10,0 11.5 10.0 11.5 10,0 HERMETIC UNITS i I - Reovr. i Nom. I Refrg. Cap." H.P. ' Lbs. Roirg. 6.6 5.7 6.6 6.6 5.7 6.6 6,6 6.6 11.5 10.0 11.5 10.0 11.5 10.0 10.0 10.0 10.0 22 34.0 • 4 22 34.0 404A 30,0 4 1 22 34,0 404A 30,0 Cond. Fens 2 2 2 2 2 2 Cond. Fans 1 1 2 2 2 2 2 2 2 2 2 1. • 1 1 1 1 PHYSICAL: DATA SEMI-HEFIMETIC UNITS Mock)! Nom. Refrg. Number H.P. Approx. Ship. Wgt. Lbs. ..;; leo 180 180 200 : jis' 210 210 215 215 215 215 220 220 220 280 280 290 290 340 340 Appmx, 8141 Wipt Lbs. PWH VIM NH 160 170 170 180 180 MINIM .-1 260 250 270 270 270 270 275 285 255 354' 310 370. .326, 370 326 387 343 387 343 ■ • ,.• ciab)-ail • 8 050M 3 $/N .030L22 i',Mtg/t4A i" 3 WD/ND 030L44 WS/NS 0401122 22 WS/NS 040M44 4 404A WD/ND 040L22 22 WD/ND 040L44 404A WO/NO 0501122 5 22 WO/NO050M44 i 404A w.o4N1 080L22 ' 6 22 ,WD/ND 060L44 404A WO/ND 085L22 ' 6 1/2 22 WD/ND 065L44 Wb/ND 0751422 WD/ND 075M44 WD/ND 0801422 WD/ND 080M44 WD/ND 0851422 „wpm!? 085M14 cs.„...../NP .9742 1 ;WO/1413.0761A4 p.0901.22 , .,WOIND . 0a01.44 WO/ND 105H22 WD/ND 10511444 WD/ND 100122 WD/ND 1001.44 WO/ND 105122 WD/ND 105L44 WO/ND 120M22 WD/ND 120M44 Wt?/ND . 150M22 WO/ND 150M44 WO/ND 1601.22 1AMMM0 150144 TO POLAR STAR REF: • 22 404A 22 404A' 22 404A 404A 22 7 1/2 404A 22 404A 22 7 1/2 404A 22 404A 922 404A 22 10 404A 22 404A 10 22 - 404A 12 22 404A 22 15 404A 22 404A Flec Cap Loa. Refrg. 34 30 34 30 34 30 34 30 34 30 34 30 34 30 63 56 63 56 63 56 63 56 63 56 83 56 63 56 63 56 63 56 63 56 63 56 63 58 • Receiver capacity (V 90% full, P . 0 i. 1 Approx. Cond. 1 1 Ship. Wgt. Fans I Lbs. 1 Outdoor Indoorj 463 419 1 1 463 419 1 ; 496 j 452 1 496 4527 1 I 566 522 . 1 i 566 522 1 527 483 1 527 483 1 566 542 1 ; 58 542 1 1 597 553 • 1 1 597 553 1 1 597 553 1 ! 597 • 553 2 ! 1143 1098 2 i 1143 2 , 1098 2 ; 2 1 1098 : 1 ! 1098 2 ! 1098 1053 2 2 1168 1126 1168 1126 2 I 1143 1098 2 1 1143 1098 2 : 2 1 1168 112: 2 I I 1168 2 I I 1208 1163 2 1208 1163 2 1 1208 1163 2 1208 1163 2 1230 1185 2 1230 1185 2 1218 1173 2 2 1210 1173 1218 1173 2 1218 1173 2 1252 1207 2 1252 1207 Model PWZ Compr. Model Electrical Data -Amps 208-230/1/60 . 206. 230/3/60 460/3/60 Compressor LRA Cond, FLA: Compressor Cond. FLA T Compressor ' Cond. FL 4 RLA . RLA LRA RLA LRA 030H22 ZB21KA 17.9 88 ; .3,2';. , ;11.4 . 77 3.2 5.7 39 030E44 ZS21 K4E 18.4 . 88 " ; ``3 2� ;;X1:1: 77 3.2 5.7 39 6 1 030L44 ZF09K4E 16.4 88:;t , 3:2 , „; 11A 77 32 5.7 39 ' 035H22 ZB28KA . 20.4 :.1.0R h N113,8, , 8 3.2 44 _ • 035E44 ZS26K4E 20.7. ',y jfM��((.�� s 1 r ; 88 3.2 ••■ 44 C.) T.' 035L44 ZF11K4E 20.7; `'_108 1 ;fie :2 6-: -A 130., 88 ' 3,2' 44 045H22 ZB30KA' 26.4 .129 v,s,2''' ; :'15.0r 99 3.2 8.2 50 045E44 ZS30K4E 26.8 129 3.2 16.0 99 3,2 8.2 50 El 045L44 ZF13K4E 26.8 1.29. 3.2 15.0 99 3.2 8.2 50 055E44 ZS38KKE 31.8 169. , 3.2 . .'21,4 123 3.2 9� 6 62 C.. (.? r 11" Ir• 055L44 7F15K4E 31.8 169 .;3.2;:: :'214 123. 3.2 9.6 62 060L44 ZF18K4E - - '' '3.2 'r: ` -23.9: ` 156 3.2 . . 7 • l)2/19? 1 0:21 Standard Features W- -Outdoor NOMINAL H.P. 005 = 1/2 HP 050 =5HP .•b.r,•. FROM JERRY tIAFZlGER J &J • Outdoor Housing with Raised Base = " • Copper Tube, Aluminum Fin Condense • PSC Fan Motors :u • Weatherproof Control Panel • Compressor Contactor • Capacitor & Relay Ass'y (1- Phase) • High and Low Pressure Control • Liquid Charging Port • Receiver w /Outlet Shut -off Valve • Suction Service Valve • Flooded Condenser Head Pressure Control PREFIX -Low Profile Model; T COMPRESSOR TYPE 5-Sethi-Hermetic-Reed D- Seml•Hermetic- Discus H- Hermetic Z- Scroll NOMENCLATURE P W Z 030 H 22 D ELECTRICAL DATA t TO POLAR STAR REF: ELECTRICAL CODE C- 230/1 /60 D-208-230/1/60 E -208- 230/3/60 H-460/3/60 M-200-220/1/50 0-380/3/50 REFRIGERANT 22 -R•22 44- R•404A'R•507 P. 07 Optionai Features • Liquid Line Assembly Drier, Sight Glass, Piping to outside • Suction Line Assembly Filter, piping to outside • Liquid Line Solenoid Valve • Oversized Receiver • insulated and heated Receiver • Receiver Relief Valve in lieu of Fusible Plug • Suction Accumulator • Oil Separator • Hot Gas Bypass, requires H.G, to evap. • Crankcase Heater (onl on 3 Ph Units axcgi4tno 10th. snAraa TEMPERATURE APPLICATION H-High M- Medium E- Extended Medium /Low L -Low h::tJaN.�L.c tin.•. n,�... �.�• n.w� Dear Sir: L. City of Tukwila Fire Department Fire Department Review Control #M97 -0179 (512) Re: Chevron - 14620 Pacific Highway South December 4, 1997 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Extend heat detection into the walk -in cooler. John W Rants, Mayor All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) 2. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Yours. truly, The Tukwila Fire Preve Bureau c c: TFD f i l e ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) .57. 541404 • Fax (206) 5754439 oki iteM tUr iSthiti Iter 7h7?!1t • f1 RECEIVE CITY OF TUKWILA DEC 021997 PERMIT CENTER 60" X 30" RETURN AIR DUCT WORK ic11or1q 36"0 RETURN AIR DISCHARGE DUCT WORK 108" WIDE R/A HOOD MOUNTED OUTSIDE OF ENVIROMENTAL CHAMBER SCALE: 1/4" = 1'- 0" 20"0 R/A DUCT SECTION: HVAC ARRAINGEMENT KRUEGER MODEL jTAD AIR DIFFUSER 675 CFM TRANE MODEL NMCCA030 "CLIMATEMASTER" AIR HANDUNE UNIT, RATED TO 12150 CFM @2" ESP R/A HOOD MOUNTED INSIDE CHAMBER (TYP 2) (A� 3M12 M522 86" X 31" OSA DUCT 44"0 SUPPLY AIR DUCT 18 "0 SUPPLY AIR DUCT 20 "0 R/A DUCT CITY OF TUKWIIA APPROVED JAN 2 7 1997 OF TIJ N CITY R OF TIIKWILA PERMIT CENTER ANNOYED IAPROIED BOEZAW FACILITIES DEPARTMENT A �U APPRIATO OR. BY K. PENROD MA Cu1 12/18/96 14 446 12RWML SUOMI HVAC SECTION MECHANICAL MASTER BLDG. 9 -99 LAST 1E1510 mIB]L SK M522 JOB 110. 757566 -07 OWE 9- 99 -M520 R.vspx aoEiivc FACILITIES DEPARTMENT ACCEPTAB Of v. Da.N K. PENROD 12/1B/96 w MIRE HVAC SECTION xn¢iox I mm� art a M 522 �. a BLDG. 9 -99 MECHANICAL MASTER - D.C. relz6h6 JOB NO. 757566 -07 — 7 12 -wk, 9- 99 -M520 60 X 30' RETURN AIR7 DUCT WORK mq� -o1�9 50" RADIUS RADIUS 105" WIDE R/A HOOD MOUNTED OUTSIDE OF ENVIROMENTAL CHAMBER 36 RETURN AIR DISCHARGE DUCT WORK 28 R/A DUCT A i I: 20"0 R/A DUCT R/6 HOOD MOUNTED INSIDE CHAMBER (TYP 2) SECTION: HVAC ARRAINGEMENT SCALE: 1/4" = 1'- 0" —. KRUEGER MODEL #TAD AIR DIFFUSER 675 CFM TRANE MODEL #MCCA030 ° CIJMATEMASTEK AIR HANDLINE UNIT, RATED TO 12150 CFM ®2 ESP 3M121 M522 86" X 31" OSA DUCT 44 "0 SUPPLY SR DUCT 18 SUPPLY AIR DUCT 20 "0 R/A DUCT CITY OF 5106D I APPROVED JAN 2 7 1957 RECEIVED CITY OF TIJKWIL4 PERMIT CENTER 9 ?. DUCT UP TN °U ROOF TO 8x8 EAR D CFM w/+2,12 FACE 8x8 EAR 10 CFM w/l2x12 FACE A74A DUCT UP ROOF TO F M4i orn 0 O A v B REEIROON 6x6 (120 2 FACE) OUTLINE OF ON ROOF W/4-K7/4 FlREEZER ©75 (12x12 FACE) r eir a doff'cp. y- 8 . 0 r , I T. • m � .A misitc b111111113111111►■ \il • • S !■ - 120 8 R/A & 12x18 S/A DUCT UP THRU ROOF TO v 11 1 10.0 .. ._... ..... I /I WALK-IN COOUER ,0x10 0 355 CFM Co ,i�11M1��I 10x10 $ 8.0 fi r! _ 355 CFM / Al 14'0 S , 4\. irtif C.D. T ' �414 _ 15x15 � "�� 0600 CFM �(18z18�FACE) 3/4" CONDENSATE DOWN TO FLOOR SINK WITH 1" AIR GAP- 1 4" 3/4" 18x24 S/A & 22x24 R/A DUCT UP THRU ROOF TO 14 "0 16" 10x1 MIT 0 14 "0 120 10x10 0325 CFM 10x 0 325 CFM 15x15 600 CFM HP -2 1041 ��yy O 'w' W/24x2 Lei (TYPIC .�. FA 00 HVAC FLOOR PLAN \ SCALE: 1/4 - 0 • J . El 0 10x10 5 C 24X24 FACE (TYPICAL) Iillllllllll © 50 CFM J EXPIRES 01 -28 -99 f W /12x12 FACE 1J/ 8x8 W/12x12 FACE 12x18 RETURN DUCT DOWN AND OFFSET TO CLEAR STRUCTURAL TRUSS BELOW ROOF J & S Consulting Engineers 175E COVE AN, MME 604 HUMAN( GAVFORN6 111502 -1232 1E1FPHON6 (H111) .1 -0603 J 6: S POW NO. 17521 450 CFM MIN. OUTSIDE AIR INTAKE WITH ECONOMIZER AND COMPLETE CONTROL KIT N v ZAIO FUVN•111 A11 00•71 f[OMmtf 16215 7.0 AVENUE SW.. KENT, 5) 251 -522 96Q52 (20 6) 251 -6222 BCEI 5781 GO- g Chevron Midway Revisions MISC. CLARIFICATIONS 3/4" CONDENSATE PIPE THROUGH ROOF WITH 4 P -TRAP. PROVIDE ROOF JACK WITH MASTIC WEATHER PROOFING. SEE DETAIL HVAC ROOF PLAN WALE 118' -U-O I 06 -19 -97 ROOF LADDER ACCESS 12x18 SU" + S • DOWN BETWEEN E STR RAL TRUSS 600 C N. OUTSIDE AIR INTAKE WITH ECONOMIZER AND COMPLETE CONTROL KIT 22x24 RETURN DUCT DOWN AND OFFSET TO MISS STRUCTURAL TRUSS BELOW ROOF 18x24 SUPPLY DUCT DOWN BETWEEN THE STRUCTURAL TRUSS 3/4" GAS LINE WITH SHUT -OFF VALVE AND DRIP LEG DOWN. SEE PLBG DWGS. FOR CONTINUATION SITE -BUILT MARKETER BUILDING for Emerald City Construction Pacific Hwy. S near S. 146th St. Tukwila, Washington SCALE: AS NOTED DR. JML CH. EV. HYAC PLANS RECEIVED CITY OF TUKN!ILA DEC 0 2 /997 PERMIT CENTER DATE: 04 -22 -97 APP. F.T. SHEET MO2 MECHANICAL LEGEND SYMBOL A@BRE;. DESCRIPTION GENERAL NOTES 1. SLOPE CONDENSATE DRAIN 10 PER FOOT (MINIMUM). PROVIDE A 5 DEEP TRAP AT THE HEAT PUMP. S CURE ROOFTOP PIPING TO REDWOOD SLEEPERS. EQUIPMENT THAT is SUSPENDED FROM 2. OR OUNiID ON VIBRATION ISOLATORS. 3. PROVIDE MINIMUM OUTSIDE NR TO HVAC UNITS AS FOLLOWS: HP -1 500 CFM 4. MAINTAIN A MINIMUM OF 10'-0' CLEAR BETWEEN HVAC EQUIPMENT MR INTAKES AND PLUMBING VENTS OR EXHAUST OUTLETS. 3. SHUT DOWN THE HP - SUPPLY FAN WHEN THE DUCT SMOKE DEIGCIUR MILLIS 8. FOR STORES THAT ME OPEN LL 24 HOURS PER DAY, AND EF - 1 SHA RUN 8. SWITCH (TS) AND INTERLOCK 2 HOURS SCHEDULED TIME STORES NTERLOCKHP -11TO SET BACK DURING UNOCCUPIED HOURS AND INTERLOCK EF -1 TO BE OFF DURING UNOCCUPIED HOURS 7. INSTALL THE HP - THERMOSTAT COMPLETE WITH OUTSIDE NR TEMPERTURE SENSOR IN OUTSIDE AR INTAKE AND SUPPLY AIR TEMPERATURE SENSOR IN MAIN SUPPLY DUCT 4' -0' - DOWNSTREAM OF HP -1. REFER TO TIME SWITCH DETAIL FOR INTERLOCKING THE THERMOSTAT WITH THE TIME SWITCH, IF REQUIRED. PROGRAM THE TIME SWITCH TO PUT THE THERMOSTAT IN SETBACK MODE WHEN THE STATION CLOSES AND RETURN THE THERMOSTAT TO OCCUPIED MODE ONE HOUR BEFORE THE STATION OPENS. PROGRAM THERMOSTAT AS FOLLOWS: A MAXIMUM SE' IPOINT - 78 F; B. MINIMUM SETPOINT - 88 F; C. COOLING AND HEATING OFFSETS •• 2 F; D. UNOCCUPIED COOLING SETPOINT - 78 F; . E. UNOCCUPIED HEATING SETPOINT - BR F; F. LOCKOUT COOLING AT OUTSIDE AIR TEMPERATURES BELOW 48 F; H. LOCKOUT CONTROL ECOND STAGE ELECTRIC RESISTANCE HEATING) AT OUTSIDE NU TEMPERATURES HOURS S 50 F; I CONTINUOUSLY; HP -1 SUPPLY FAN SkIAL1 RUN J. SHUT OFF HP - SUPPLY FAN WHEN THE SUPPLY AR TEMPERATURE DROPS TO 38 F. B. SET THERMA FUSERS TO HEAT TO 70 F AND COOL TO 74 F. y —1 CO CEILING DIFFUSER (SIZE AND CFM NOTED) 4-7-- RAC RETURN AIR GRILLE, CEILING ill 1 4 - x - PG EXHAUST AIR GRILLE - c DG DOOR GRILLE L LOUVER DRAW BAND -, o INSULATED DUCT. SEE FLOOR B FOR SIZE. MAXIMUM 7' - LONG -- W � � MEfPL PLENUM METAL DIFFUSER NECK CEILING DIFFUSER r FD, AFC FORE DRAPER, AUTOMATIC FD (NOTED) VD VOLUME DAMPER I BOO B DRAFT DAMPER (NOTED) i RRD BAROMETRIC RELIEF DAMPER (NOTED) I 1 2.12 DUCT SIZE, FIRST NUMBER IS SIDE SHOWN FC FLEXIBLE CONNECTION L Q TURNING VANES W.DIFFUSE NECK WIDTH PLUS 2' H.. DUCT DIAMETER PLUS 2' MINIMUM �T)� EL 1. IN LIEU OF PLENUM SHOWN A FULL SIZE ROUND SHEET METAL ELBOW MAY BE USED TO CONNECT FLEX DUCT TO DIFFUSER. ELBOW R/D - 1.5 - IFFUSER CONNECT `l DET / +' - CEMOUSH (E) DUCTS, PIPING OR EQUIPMENT UNED DUCTWORK !� �1 /� �1 F1 FJ(I[JlE DUCTING V V V V V " �t ._' DUCT SECTION, POSITIVE PRESSURE C:,'Ci SECTION, NEGATNE PRESSURE is QT T THERMOSTAT O S REMOTE THERMOSTAT SENSOR ® SD SMO✓.E DETECTOR ) -N- PONT OF CONNECTION PONT OF DEMOLRTON E TESTER LINE AFF ABOVE FINISHED FLOOR BFT BELOW FINISHED FLOOR wN DWG DDRRAIPING (E) EXISTING MC NOT IN CONTRACT Nis � / v SECURE UNIT TO CURB WITH 1/4" DIAMETER CAD PLATED LAC SCREWS 16' OC ON THE TWO OPPOSING LONG SIDES. (3-SCRE1VS MIN. PER SIDE) N ISOLATION RELAY DIE `• 24V F9 EF - 1 ISOLATION RE.AY SA SERIES TUX NTS NOT TO SCALE CM OUTSIDE AIR . a r PAD ORD OPPOSED BLADE DAMPER R NEOPRENE SAD SEE ARCHITECTURAL DRAWINGS -- i FAB INS ULATED 12L HP-i ,'„ E4r COMM COUNTER FLASHING - - PRE SLA SEE CIVIL ORA1V9 N.4 CURB 1*2 �+� SID SEE EECTIaC/J_ DRAWINGS / ROOFING, SAD. SPD SEE PLUMBING DRAWINGS 5SD SEE STRUCTURAL DRAWINGS ,44_%!:.12, TYP TYPICAL (.NC UNIFORM MECHANICAL CODE I UNLESS NOTED OTHERWISE § � E § g. .. (.[ {g N ! ; ! &§ ' ( »£ ' §§§ � E �a¢k: �kEk' , m 7|§ 1§M ROOF DECK I 2' PENETRATION TIMESWITt21 (IS) ( 8 -72 VOC (RADIO SHACK /273 -1455) / , (i r 901 SECURE CURB TO ROOF STRUCTURE 4X (MIN) BLOCKING BATERY i) • SWITCH 0 WITH 1/4' DIAMETER LAG SCREWS 5.5.0. THIS DETAIL APPLIES TO STORES THAT ARE NOT - OPEN 24 HOURS PER AMY. SEE GENERAL NOTES. Woe AU. AROUND CURB, S.S.D. CD -1 OElLPH OPPOSER MODEL TITUS DINS _ 0 LOCATE SWITCH, LICFfT A BATTERY IN LOCA SWI C UGH n DESCRiPTXNK FRAME ^rE TO MATCH CLANG CONSTRUCTION CD CEILDNG DIFFUSER MOTEL: ACUTE,. ',ER/AA TF -H C DESCPJRROtt VAN' HEA'NO AND COOLING CONTROL EAG -t EXHAUST 6RLLE MODEL TITU55DF NP -1 MOUNTING DET74IL 1. WITH NO VOLTAGE ON C LI NE , . TUX OPERATES IN OCCUPIED MODE. WITH 1 2. WITH CONSTANT DC POWER ON COMM. LINE TUX OPERATES IN UNOCCUPIED MODE. 3. LOCATE T5 IN OFFICE OR PER OWNER'S INSTRUCTIONS M E SWITCH DETAIL TIME DESCROO'TTOit EGG ATE, X 1/2' X ALUMINUM E* GRID CONSTRUCTION O FRAME TO MATCH CONON P: E T; H CEILING BORDER: EF - EXHAUST FAN NISI MOTEL: t,TRIENHECK SP -7 CAPACITY: 98 CFM AT 0.25 5° ELECITRCM.: 120 VOLT, 50 WATTS WEIGHT: 30 LBS ACCESSORIES: BNEETRAFT DAMPER, MOTOR THERMAL OVERLOAD PROTECTION, ELECTRICAL DISCONNECT (UNDER FAN HOOD). ROOF CURB AND ROOF CAP Fry -1 HEAT POW, ROOFTOP PACKAGED MODEL• HONE WC015093 CAPACITY: 145 MOH TOTAL COOLING AT AFB CONDITIONS 138 MBH HEATING AT ARRI CONDITIONS ARFLOW: 4400 EFM AT 0.5 ESP , 1 ` • . EFFICIENCIES: 9.1 REP, 3.0 COP v ELECTRICAL_ PHASE. 208 VOLT. 3 PH/S SINGLE POINT POWER ENTITY. 166/150 MCA, 175/200 MOCP W/ 2 HP INDOOR FAN MOTOR AND 27.0 /35.0 KW HEATERS WE7GIIT: 1,760..5 .SECURE UNR TO CURB AGI SSORFS: M000LAPNG INTEGRATED ECONOMIZER, POWER DATAUST, WITH I}10 GALVANIZED ROOF CURB AND FILTER RACK S.M.S. TWO PER SIDE !ill$ 2 ■ Chevron Products Company, a dNI of Chen an U.SA Inc., awns" the copyright rights to the design of the Arch deearbed bulldkg ae embodied In my tangible Or medium of mere:Mon bduding WIIdFIq, architectural plan, ar drowegs: ms eopyrl¢ntedmatsrbl ° includes the over. form as wee as the urrmgwnent and composition of spaces and elements In the de., but doss. not Include Indi of standard features. Amon* who Ashes to copy dlslrWle, or sell the drawing ar army derhathe wake bowed hereon must Nene written permission of Chswon Products l'wwAlpvey elicept for eopbs mode for the ede purpose of preparing con...Um drawings for Chevron branded foal.. and, d d on such copies eh be returned to Chevron up request Both tM drawings and ...tarot �izlatlmne, If Included, cos ganerb worrt and not desl for dte applications. Urwrr'on warrant of guaranty ets oulocal the m Consult cr °F opp WP g iTty J of A at en e !^ the r•qu4mwl of your bed uea. Carlelret a , WW1, coda Qglnasr to de r e any site Inc design, architect municipal tpd r•quYrmt Chevron eChevron g not pew/. Owes centime. 01997 Chevron Products Dsrpany. a Adslcn. of Chevron U.S.A. Inc_ A. Tights reserved i PAD , .& NEOPRENE RAG-1 RETURN GRILLE s 4 MODEL: TI US 50' IA • INSULATED OF.SCRIPTORN: EGG C 'E. 1/2' r v, 1/Y X 1 /z' I ALUMINUM GRID AND • 4 CURB BORDER, F?euE 1TrF TO MATCH CLUNG COtNSTRUCHON Iiiii ROOTING, SAD. SD ROOF DECK MOT NR DETECTOR I NTRS LTD MODEL MS -02 /: j4�• MODEL: A F'P.CC'.`OTS AND CONTROLS 4N N OfSCFIIPTott 24 VAC; ALARM LED; RESET BUTTON � - - T MODEL: ALERTOOO SA TUX CONTROLLER WIi}i MI(7tp$ET THERMOSTAT FOR ETOl il I � MODEL THERMOSTAT, OUTSIDE AIR TEMPERATURE SENSOR. DUCT , TEMPERA" _ °E SENSOR MODEL/ T- 101 -0 -22, REMOTE WALL PENETRATION ` N MIN) MOUNTED TE MPERATURE SENSOR MODEL) T- 101- 1- SWP -22 4X ( MIN) BLOCKING ELECTR +L: 24 VAC DESrPTPTOrK TO PURCHASE CONTACT RE.FRESENTAThE AT TS TIME swrcH (USE ONLY Ie ..)SPED. MODEL: FARAG, EC -72D 120 VOLT FEIAR 2- QN'NE1; 7 -DAY FEATURES: W Mq t- SECURE CURB TO ROOF ALERTON NATIONAL ACCOUNT STRUCTURE TfITH 8 S.S.D. WOOD SCREWS, (2 P 707- 778 -7890 EXTENSION 212 ) SEE GENERAL NOTES) SIDE. (MIN.) 12 O.C. PROGPIJBYINI.E; HOLIDAY SCHEDULING RECEIVED ,'. (g3! E1 -1 MOUNTING DETAIL CITYGFTUM ChM /RES: p vmfl ®! RMC2112 -A cod REMOTE MARKETER YfOOD -ENS LEGEND. SQ1EDlILE, NOTES R DETAILS Marketing ""!! . ' ARCHITECTURE • ENGiNEERING jA *ENVIRONMENTAL SERVICES : 9a! lR 7177 R N.A. AWL FERMI& GA 007) 7R -11E9 MB It Allen Mini OMB IL RAT, O7L QOM ,,, ,�,,, DR. CORP. S SHOWN DATE JAN 97 R DR CD EV. CH S.IB APP. RCR o _ NTS PERMIT CENTER O MO1 O grki 51 F>Lt 10 "0 340CFM 24 - X48' • • 10 -0 � �41 IR #4 �: 340CF . � /`Q�, .1',,' . -!� D OWN Ci , ®LEXIB CTION I ■ Rom . TOR RN sLE rl M� .'�lu 4• ■/ ■.__..�.:��- -i � 'r �, , �— � — IN sa lilt.. II • rr l - 1162 m' o mmalomirimmourq im um ihme BOCFM 12 480CFM 12'0 480CFM 12 "0 460CFM 0 - 0 200CFM 0 1" CONDENSATE DRAIN FROM HP -1 TO FS. PROVIDE 2 AIROAP 20CCFM 50CFM 6 -0 0 120CFT4 S [ `U MIN -1120CFM Xl � „ t 400CF1d fgd e Ira D�FM p. 8 "0 5 w-3 60 75CFM 12'0 400CFM ECEIVED CITY R OF TUKWILA DES.': +2i.9 PERMIT CENTER NOT Ti18 DRAWING 18 FOR A PROTOTYPICAL FACLfY MD 18 NOT SITE 8PECFIC. DO NOT USE FOR V Chevron Marketing Rerblorw Chevron Products Gammon, a division at Chevron U.S.A. h ., owns the copyright rights to the dedpn of the herein desarbed building as embodied M any tangible or electronic medium of egnesetur Including a building, architectural plans, ar drawing. The copyrighted matelot include. the overall form as well as the arrangement and composition of emotes and dements In the deal , but doe not Include I ndivldud etandord features. Anyone who wields to copy, dletrbuts, or eel tO. drawing or any derivative works boned hereon most have written permission of Chevron' Products Company except for . 4.. made for the sole purpose of preparing construction drawing. for Chevron braided faculties and, all web cools. ehdl be returned to Chevron upon ..Quest. Both the drawing. and structural cda/atlons, if included, are generic and not designed for sib specific u ppikoticns. Chevron dose not .arrant or guaranty the ornns, or oppUcobfity of either to the requirement. of ya.T load area. Commit a registered on thlt.d or prafeesiond engineer to determine ony site specific design, acceesibillty, building cods, or monlcipd requirements.' Chevron doe not provkle these .O... 01197 Chevron Products_Canpany, a division of Chevron U.S.A. Inc. AA rights reserved. RMC2112 — A td REMOTE MARKETER MOOD —FRAME 11VAC PLAN ARCHITECTURE • ENGINEERING •ENVIRONMENTAL SERVICES a" ma 1137 w Md R1L o f PEfKIMA G tN/l 7P3- l AN [ AlFAdt Ms311ECf 7e6I1 Mi, gGi F7R14F71 t iYW SCALE 1/4 " -1' -0 DATE 31 JAN 97 DR. CORP. DEV. CH. SBJ OPP. NCR MEET MO2 HVAC LEGEND SYMBOL DESCRIPTION Lai DUCTWORK -1 et DIMENSION IS SIDE SHOWN, 2nd DIMENSION SIDE NOT SHOWN Wall ROOF IV=;14 FLEXIBLE INSULATED DUCTWORK YORK DUCT SIZE TRANSITION (SE i \ ROUND DUCT VERTICAL RISE /DROP F-i: RECTANGULAR DUCT VERTICAL RISE /DROP ACE- D /70C15DM GRADUAL RISE/DROP N DUCTS EMI TOTAL A!R,CFM 0 0 Y ®} VERTICAL TAKE -OFF UP MI ES VERTICAL TAKE -OFF DOWN 600 MIN RECTANGULAR DUCT 90 DEGREE MITERED ELBOW WITH TURNING VANES } .86 RECTANGULAR DUCT ANGLE TAKE -OFF } } FD SD FIRE DAMPER /SMOKE DAMPER, COMBI- NATION SMOKE & FIRE DAMPER - PROVIDE ACCESS DOOR & CEILING ACCESS 1-1/2 2 MANUAL VOLUME DAMPER BELT BELT 30MdlNO4d d DUCT UNDER POSITIVE PRESSURE - SUPPLY AR OR FAN DISCHARGE 59 87 VI DUCT UNDER NEGATNE PRESSURE - RETURN OR OUTSIDE AUR 71 EXHAUST DUCTWORK ® 12X12 CD 300 CEIUNG DIFFUSER/REGISTER 12'X12" NECK, 300 CI AIR FLOW (D M ,S THERMOSTAT (MONITOR, SLAVE) - `c") DUCT SMOKE DETECTOR e 1 EQUIPMENT IDENTIFICATION - -- LOW VOLTAGE WRING IN MECHANICAL WORK S UNE VOLTAGE WIRING IN ELECTRICAL WORK S O FURNISHED AND INSTALLED IN ELECTRICAL WORK O FUR'SHED AND INSTALLED IN MECHANICAL WORK M ® HAN FURNISHED RN MECHANICAL WORK AND INSTALLED IN ELECTRICAL WORK O TEMPERATURE SENSOR A/C UNIT SCHEDULE UNIT DESIGNATION 41221 0 Lai 1© LOCATION ROOF ROOF MAKE YORK YORK MODEL - DCGO60N079 D4CG090N130 REMARKS ACE- D /70C15DM VCR- 120V2B ''. rrvd 8000w I TOTAL A!R,CFM 2000 3000 OUTSIDE AIR,CFM 450 MIN 600 MIN EXTERNAL S.P.- IN.W.G. .60 .86 FAN RPM 1009 1130 FAN MOTOR HP (NON-OVERLOADING) 1-1/2 2 DRIVE BELT BELT 30MdlNO4d d GROSS COOLING CAPACITY, MBH 59 87 SENSIBLE COOUNG CAPACITY 0 67 WB EAT, MBH 46 71 SEER /EER 10.15/9.4 -/8.9 SOUND RATING, BELS (ARI 270) 8.6 9.0 HEATING INPUT /OUTPUT, MBH 080.5% AFUE 100.0/79.0 163/130 ECONOMIZER TYPE INTEGRATED ENTHALPY INTEGRATED ENTHALPY ECONOMIZER CAPACITY 2000 CFM 3000 CFM ELECTRICAL VOLTS /PHASE 208 -230/3 208 -230/3 COMPRESSOR RLA 16.7 28.2 OUTDOOR FAN FIA 2.3 4.6 INDOOR FAN FLA 6.0 7.5 MINIMUM CIRCUIT AMPACITY 29.2 47.3 MAXIMUM OVERCURRENT PROTECTION, AMP 45 70 OPERATING WEIGHT. LBS 900 1500 FILTER SIZE - INCHES (1) -14x21 (2)- 14x2Ox1 xt (2)- 2024x2 (2)- 16 FAN SCHEDULE UN TT DESIGNATION Alk Gil MY VT LOCATION ROOF HOOF AREA SERVED TOILET HOT FOOD MANUFACTURER LOREN COOK LOREN COOK MODEL NO. ACE- D /70C15DM VCR- 120V2B Mdd FAN TYPE OO ( O AIR VOLUME (CHAR) 110 ' 600 TOTAL STATIC PRESSURE (IN.W.G.) 3/8" 1/2" WHEEL TYPE BACKWARD INCUNED BACKWARD INCUNED MAXIMUM RPM 1670 1110 801011 MAXIMUM BHP (NON - OVERLOADING) - 0.09 WATTS 92 - HP 1/20 1/6 VOLTS /PHASE 120/1 120/1 DRIVE DIRECT BELT S318OS530DV BACKDRAFT DAMPER YES ( NO MOUNTING . ROOF ROOF OPERATING. WEIGHT (LBS.) 50 75 OPERATION CONTROL 0 O ACCESSORIES ROOF CURB ROOF CURB REMARKS 1 I () NOTES; ® RUN CONTINUOUSLY ® SWITH WITH PILOT LIGHT POWER ROOF VENTILATOR UPBLAST POWER ROOF VENTILATOR AIR DISTRIBUTION SCHEDULE SYMBOL SERVICE FACE TYPE MATERIAL - MANUFACTURER MODEL No. REMARKS AO SUPPLY PERFORATED -2" DEEP AIRFLOW LOUVERS ALUMINUM ANEMOSTAT PR SERIES 0 RETURN CURVED LOUVERS, 3/4 O.C., HINGED ALUMINUM ANEMOSTAT 3P @ SUPPLY SQUARE STEPPED CONE ALUMINUM ANEMOSTAT XDF © RETURN 3/4 LOUVERS, 3/4" 0.C. ALUMINUM ANEMOSTAT X3HOD 1. a PROVIDE ALL HEATING, VENTILATING AND AIR CONDITIONING TEAS INDICATED ON THE DRAWINGS, DESCRIBED IN THIS SPECIF1CATION, OR REQUIRED FOR A COMPLETE AND PROPER INSTALLATION. HVAC WORK INCLUDES THE FOLLOWING: 3. 4. Mqol7q HVAC SPECIFICATIONS 1. HVAC UNITS AND EQUIPMENT; 2. EXHAUST FANS; DUCTS. FILTERS. DAMPERS, GRILLES, REGISTERS. DIFFUSERS; CONTROLS, INCLUDING 24 VOLT CONTROL WRING AND 120/24 VOLT TRANSFORMERS; 5. CONDUIT FOR LOW VOLTAGE WIRING; 6. INSULATOR FOR DUCTS AND PIPING AS REQUIRED IN THIS SECTION; 7. CONDENSATE PIPING. B. RELATED WORK DESCRIBED ELSEWHERE: 1. LINE VOLTAGE WIRING, CONDUIT AND DISCONNECT SWITCHES. 2. COMPLY WITH ALL PERTINENT CODES, ORDINANCES AND REGULATIONS, AND ALL PERTINENT RECOMMENDATIONS CONTAINED IN ' HVAC DUCT CONSTRUCTION STANDARDS' AS PUBLISHED BY SMACNA, THE UNIFORM MECHANICAL CODE (UMC), LATEST EDITION. 3. FURNISH, WITHOUT EXTRA CHARGE, ANY ADDITIONAL MATERIAL AND LABOR REQUIRED TO COMPLY WITH THE ABOVE CODES MID STANDARDS, EVEN THOUGH THE WORK MAY NOT BE DESCRIBED IN THE CONTRACT DOCUMENTS. WHERE THE REQUIREMENTS OF THE CONTRACT DOCUMENTS EXCEED THE REQUIREMENTS OF THE ABOVE CODES AND STANDARDS, THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE. 4. AFTER AWARD OF CONTRACT AND BEFORE COMMENCING WORK. SUBMIT SIX COPIES OF THE FOLLOWING TO THE ARCHRECT FOR APPROVAL SUBMITTALS SHALL BE IN BROCHURE FORM WITH INDEX AND SELECTED ITEMS CLEARLY DESIGNATED AND REFERENCED TO THE APPROPRIATE EQUIPMENT TAG NUMBER: 0. COMPLETE MATERIALS UST OF ALL REVS PROPOSED TO BE FURNISHED AND INSTALLED UNDER THIS SECTION; B. CATALOG CUTS AND OTHER DATA REQUIRED TO DEMONSTRATE COMPLIANCE WITH THE CONTRACT DOCUMENTS. 5. COOPERATE WITH OTHER TRADES IN ORDER THAT ALL SYSTEMS IN THE WORK MAYBE INSTALLED IN THE BEST ARRANGEMENT. 6. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE INSTALLED. CORRECT CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. NOTIFY ARCHITECT OF ANY DISCREPANCIES. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 7. AVOID INTERFERENCE WITH STRUCTURE. AND WITH WORK OF OTHER TRADES. INSTALL ALL EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS INSTALL ACCESSIBLE PARTS, INCLUDING EQUIPMENT, COILS, VALVES, DAMPERS, CONTROLS. AND FILTERS WITH ADEQUATE CLEARANCE FOR INSPECTION, ADJUSTMENTS. REPAIR, AND REPLACEMENT. 8. ALL OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND PROPER, INSTALLATION, SHALL BE AS SELECTED BY THE CONTRACTOR SUBJECT TO ACCEPTANCE BY THE ENGINEER. 9. GALVANIZED SHEET METAL DUCT: PER SMACNA ' HVAC DUCT CONSTRUCTION STANDARDS AND 1994 UMC CHAPTER 6. ID. SOFT FLEXIBLE DUCT: CODY -WEST TYPE NIL 7' - MAXIMUM LENGTH UNLESS NOTED OTHERWISE. 11. INSULATION: MI. -FACED FIBERGLASS, OWENS - CORNING TYPE 75 OR EQUAL, I- 1/2" THICK. FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE - DEVELOPED RATING OF NOT MORE THAN 50. 12. DUCT UNER: FOR EXTERIOR DUCTS: FIBERGLASS 1 -1/2 THICK WITH FIRE RATED BLACK COATING, 1 -1/2 LB. PER FT3 MINIMUM DENSITY, OWENS CORNING AEROFLEX TYPE 150. FOR OTHER LOCATIONS SHOWN ON. DRAWINGS: AEROFLEX TYPE 150, AS ABOVE EXCEPT 1" THICK. FLAME SPREAD RATING OF NOT MORE THAN 25 AND SMOKE DEVELOPJD RATING OF NOT MORE THAN 50. 13. CONDENSATE PIPING: TYPE 'L' COPPER, SWEAT FITTINGS. 14. PROVIDE APPROVED FIRE AND SMOKE RATED FLEXIBLE CONNECTIONS BETWEEN FANS AND DUCTS. 15. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. 16. PAINT ALL DIFFUSER, GRILLE AND REGISTER BACK PANS FLAT BLACK. 17. MAKE ALL DUCT ELBOWS RIGHT ANGLE TYPE WITH DOUBLE - THICKNESS TURNING VANES WITH A CENTERLINE RADIUS 1 -1/2 TIMES THE DUCT WIDTH. 18. DO NOT CUT INTO OR REDUCE THE SIZE OF ANY STRUCTURAL MEMBER WITHOUT THE PERMISSION OF THE ARCHITECT. 19. PROVIDE WEATHER -PROOF FLASHINGS AT ALL DUCT AND PIPE PENETRATIONS THROUGH THE BUILDING WALLS AND ROOF. AS A MINIMUM, FLASHINGS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS. FLASHINGS SHALL BE GUARANTEED WEATHERPROOF FOR THE DURATION OF THE ROOFING GUARANTEE. 20. THOROUGHLY CLEAN ALL COMPONENTS AND REMOVE ALL DIRT, SCALE, OIL, AND OTHER FOREIGN SUBSTANCES. PROVIDE CLEAN AR FILTERS. FOR ALL EQUIP- MENT. 21. NOTIFY THE ENGINEER AT LEAST 24 HOURS PRIOR TO COVERING OR ENCLOSING WORK. DO NOT ALLOW OR CAUSE ANY OF THE WORK OF THIS SECTION TO BE COVERED UP. OR ENCLOSED UNTIL IT HAS BEEN OBSERVED AND ACCEPTED BY THE ENGINEER AND BY ALL OTHER AUTHORITIES HAVING JURISDICTION. 22. PERFORM ALL TESTS NECESSARY TO DEMONSTRATE THE INTEGRITY OF THE COMPLETED INSTALLATION TO THE APPROVAL OF THE ENGINEER AND ALL OTHER AUTHORITIES HAVING JURISDICTION. MAKE ALL ADJUSTMENTS NECESSARY AND BALANCE THE COMPLETED SYSTEM IN ACCORDANCE WITH THE DATA SHOWN. BALANCE THE SYSTEMS IN ACCORDANCE WITH NEBB OR AABC STANDARDS. MAKE THE FOLLOWING TESTS AND SUBMIT REPORTS TO THE ARCHITECT: A_ AIR VOLUME AT EACH SUPPLY, RETURN AND EXHAUST OUTLET OR INLET. B. VARIABLE VOLUME VALVE MAXIMUM AND MINIMUM FLOW RATES. C. TOTAL CFM MD TOTAL STATIC PRESSURE OF EACH SUPPLY AND EXHAUST FAN. TEST EXHAUST FANS WITH ROOM DOORS CLOSED. D. MOTOR SPEED, FOR MULTIPLE SPEED FANS (EG. HIGH, MEDIUM. LOW). E. OUTSIDE MR TO EACH HVAC UNIT AND SUPPLY FAN. 23. THE ENDRE SYSTEM SHALL BE WARRANTED FOR A PERIOD OF ONE (1) YEAR BEGINNING WITH OWNER'S ACCEPTANCE OF THE WORK. ALL LABOR AND MATERIALS NECESSARY TO REPAIR OR REPLACE THE SYSTEM. OR PORTION'S THEREOF. DURING THAT TIME SHALL BE WARRANTED FOR A PERIOD OF ONE (1) YEAR FROM THE REPAIR OR REPLACEMENT. 24. INSTRUCT OWNER'S REPRESENTATIVE IN THE OPERATION OF THE SYSTEMS. 25. PROVIDE ONE REPRODUCIBLE (SEPIA) AS - BUILT DRAWING AND AN OPERATION AND MAINTENANCE MANUAL AS A MINIMUM, THE MANUAL SHALL CONTAIN: B. A COMPLETE LIST OF ALL EQUIPMENT AND APPURTENANCES WITH EQUIPMENT DESIGNATIONS (PER DRAWINGS), MANUFACTURERS, AND CATALOG NUMBERS. COPIES OF MANUFACTURERS BROCHURES. AND INSTRUCTIONS FOR OPERATION AND MAINTENANCE OF ALL MECHANICAL EQUIPMENT, INCLUDING REPLACEMENT PARTS USTS. C. TYPED SYSTEM OPERATION AND MAINTENANCE INSTRUCTIONS, INCLUDING INSPECTION, LUBRICATON, AND SERVICE INSTRUCTIONS AND SCHEDULES. D. UST OF NAMES, ADDRESSES AND PHONE NUMBERS OF DISTRIBUTORS OF ALL EQUIPMENT AND APPURTENANCES. E. MANUFACTURER'S WARRANTIES. J a S PR0.1. no. 17521 vnA n ww NO tow veAEslr tem 7940 AVENUE 5421 (log) 1-8222 .1 BCE1 5 01 Chevron Matedng Revisions Q1 MISC. CLARIFICATIONS i 06 -19 -97 SITE -BUILT MARKETER BUILDING tor. Emerald City Construction Pacific Hwy. S near S. 146th St. Tukwila, Washington SCALE: NONE DR. JML DATE: 04 -22 -97 CH. EV APP. FT. HYAC LLEc21 ,, NOTES AND Jy SHEET: I EXPIRES 01 -28 -99 I R'-CEIVEO CI?V CF 7UKJJILA DEC D 21997 PEP, MIT CF': P.