HomeMy WebLinkAboutPermit M97-0188 - INNOVAr (\ D
City of Tukwila ! �; (206) 431 -3670
Community Development / Public Works * 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
Permit No: M97 -0188
Type: B -MECH
Category: NRES
Address: 3315 S 116 ST
Location:
Parcel #: 092304 -9068
Contractor License No: IECS * * *044QL
TENANT INNOVA
3325 S 116 ST, TUKWILA WA 98168
OWNER SEAGATE /GATEWAY NORTH PROP
C/O KEMPER R/E MGMT CO, PO BOX 1459, LAFAYETTE CA
CONTACT JOHN FITZPATRICK Phone: 206 -439 -2746
3325 S 116 ST, TUKWILA WA 98168
CONTRACTOR IECS INC.
P.O. BOX 19252, SEATTLE, WA 98109
********************************************* * * * * * * * * * * * * * * * * * * ** * * * * * * * * **
Permit Description:
INSTALLATION OF (3) 20 TON AC "UNITS
UMC Edition: 1994
* * * * * * * * * * * **
Perm t Center Au horized Signature Date
I hereby certify that.I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied,with,.whether specified herein or not.
The granting of, his permit does not presume to give authority to violate
or cancel the p,}•visions of any other state or local laws regulating
construction • the , ,rformance of work. I am authorized to. sig for and
obtain this in /Germit
Signature:_ Date.:
Print Name
MECHANICAL PERMIT
**************************! t * * * *** * * * * *** * ** * * * * * ** * ****
/ r
Title:
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the,.work is suspended or
abandoned for a period of 180 days from. the last inspection.
Valuation:
Total Permit Fee:
Status: ISSUED
Issued: 01/06/1998
Expires: 07/05/1998
Phone: 206 939 -9495
60,000.00
77.19
Project Name/Tenant: =
Description of work to be done;. ,-,N 2O "C"Wi ,A v/J I t�
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes Erne
Attach list of materials and storage location on so•arate 8 1/2 X 11 •a• orindicatin. •uantities & Material Safet Data Sheets
--
11 Above Ground Tanks U Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof
❑ Demolition ❑ Fence 10 Mechanical ❑ Manufactured Housing - Replacement only
❑ Parking Lots ❑ Retaining Walls U Temporary Pedestrian Protection /Exit Systems
❑ Temporary Facilities ❑ Tree Cutting
Valu9 of Const� ion:
Site Address:
j 3 2 �. .
�
l l(S- - ,
City State /Zip:
(.�001_4_.ic, o
Tax Parcel Number:
--1--4 I ! - 5-2_6 f '
Property Owner; /J 4 ti Q-
City /State /Zip:
Phone -0 6
4 R (:,
Street Address:
0 Metro
0 Standby
City State /Zip:
Fax #:
Contact Person:
Phone:
Street Address:
City State /Zip:
Fax 41:
Contractor: �
Phone:
Street Address:
'3c99 G� ��4
Architect:
';
�
City State /Zip:
� 2[1� State/Zip:
Fax #:
Phone:
Street Address:
City State /Zip:
Fax 41:
Engineer:
Phone:
Street Address:
City State /Zip:
Fax #:
MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) ..:,
Description of work to be done;. ,-,N 2O "C"Wi ,A v/J I t�
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes Erne
Attach list of materials and storage location on so•arate 8 1/2 X 11 •a• orindicatin. •uantities & Material Safet Data Sheets
--
11 Above Ground Tanks U Antennas /Satellite Dishes ■ Bulkhead /Docks ■ Commercial Reroof
❑ Demolition ❑ Fence 10 Mechanical ❑ Manufactured Housing - Replacement only
❑ Parking Lots ❑ Retaining Walls U Temporary Pedestrian Protection /Exit Systems
❑ Temporary Facilities ❑ Tree Cutting
MONTHLY SERVICE BILLINGS TO:
Name:
Phone:
Address:
City /State /Zip:
0 Water
0 Sewer
0 Metro
0 Standby
CITY OF r'K WI LA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
F' ' STAFF USE ONLY
Project.Number:
PermItNumber:
Miscellaneous Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mall or facsimile.
APPLICANTREQUESTS FOR MISCELLANEOUS PUBLIC WORKS PERMITS:'
❑ Channelization /Striping
❑ Flood Control Zone
❑ Landscape Irrigation
❑ Storm Drainage
❑ Water Meter /Exempt II
❑ Water Meter /Permanent #
❑ Water Meter Temp #
❑ Miscellaneous
WATER METER DEPOSIT /REFUND BILLING:
Name:
Address:
Date application accepted:
t•- t•°1'
MISCPMT.DOC 7/11/96
❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s):
❑ Land Altering: 0 Cut cubic yards 0 FIll cubic yards 0 sq. ft.grading /clearing
❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Street Use ❑ Water Main Extension 0 Private 0 Public
0 Deduct 0 Water Only
Size(s):
Size(s):
Size(s : Est. quantity: gal Schedule:
Moving Oversized Load/Hauling
City /State /Zip:
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall
expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days
upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application
shall be extended more than once.
Date application expires,. •gye
Phone:
Applicatio n by: (initials)
BUILDING u • - OR ' /T ORIZE AGENT:
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR
Above Ground Tanks/Water Tanks - •Supported directly upon grade
exceeding 5,000 gallons and a ratio of height to diameter or width
which exceeds 2:1
SignatureI` /9� / 7 �
in
Date: 17. .
Print name." C �� LC.... - ,,,
®
PS�, "-'ZIc)!j
6 1 : _ JIL . u �
<-4: `awl — %z
)
/ �s � t � � � Z 2 , , , L if I �� �
I
Address: 6,._(.2 k'V ,i UA 6 LIn'� t�l
G� 2 ()f.) 1
`
0
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR
Above Ground Tanks/Water Tanks - •Supported directly upon grade
exceeding 5,000 gallons and a ratio of height to diameter or width
which exceeds 2:1
PERMIT REVIEW
Submit checklist No: M -
in
Antennas /Satellite Dishes
Submit checklist No: M -1
®
Awnings /Canopies.- No signage
Commercial Tenant Improvement
Permit
0
Bulkhead/Dock
Submit checklist No: M -10
El
Commercial Reroof
Submit checklist No: M -6
0
Demolition.
Submit checklist No M -3, .`M -3a
0
Fences - Over 6 feet in Height
Submit checklist No: M -9
0
Land Altering /Grading /Preloads.
Submit checklist No: M -2
Loading Docks
Commercial Tenant Improvement
Permit. Submit checklist No: H -17
Mechanical (Residential & Commercial)
Submit checklist No M -8,
Residential only - H - 6, H - 16
0
Miscellaneous Public Works Permits
Submit checklist No H -9
0
Manufactured Housing (RED INSIGNIA ONLY)
Submit checklist No: M - 5
0
Moving Oversized Load /Hauling
Submit checklist No: M - 5
Ell
Parking Lots
Submit checklist No: M -4
O
Residential Reroof - Exempt with following exception: If roof structure
to be repaired or replaced
Retaining Walls - Over 4 feet in height
Residential Building Permit
Submit checklist No: M -6
Submit checklist No:. M -1
El
El
Temporary. Facilities
Submit checklist No: M -7
in
Temporary Pedestrian Protection/Exit Systems
Submit checklist No: M -
®
Tree Cutting
Submit checklist No: M - 2
ALL MISCELLANEOUS PE' APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING:
. .
> ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
D BUILDI09 SITE ePLANS; ND UTILITY PLANS ARE TO BE COMBINED
• ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT
STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON
LICENSED STRUCTURAL ENGINEER
• CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER
(P.E.)
Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,or, contractor licensed .
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal.
I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS
PERMIT. l
I /1
MISCPMT.DOC 7/11/96
Address 3315
Suite:
Tenant: INNOVA
Type B -MECH
Parcel #: 092304 -90 68
M97 -0188
Status: ISSUED
Applied:,12 /.18/1997
Issued: 01/06/1.998
lk'* ***• • k
k*• k "'k•k•k * * *•k : * *k *•k.A•:*•k.t ` k.• k
A k*k*" k�k,• k) k; k
* A* A• k' k • A*
kkkk• k• k`k:k*
'k* *_** **
P Cond.1tion
1 be Made tp the plan::, ,unless : approved by th,e
Architect.or Enginneer and the Tulwi1a Bu11ding. Division.
A1.1 permit_ ir�specticari. r Lco and.. ppra�r {Tans shall be available at the .j,ob situ .r.ic�r :to the tarY.t. +a1 any con
traction. These -1:d0cument* are to b,e maintalned and avai 1-
.a�ile until :final i'n pee "t!on; approval , :i.s grian;ted
3,. All constt not :tp'n to <.be done' in 'conformance with ai r ratted
p tans and ,rw,eyu 1 renient. "-of the U r 1 form Bu 1 1 d.i ray, Code 11994
Edition 1 iorm MechaniC�i`'Gode `'C 1994 Edition
and .Washington to t'e Erier �, y- i ucie '' f Edition)
'Ja,1 � cli t;y. iif Prrr nit. The 1 suahee o4 a perm t or `'app.rova 1 'o:f
'plans,.: s:pecif 1 cat i,o pe:r " " 'rys., .andc.-canrputat`ions 'she 11 riot b
s
trued, :to loe` a nri t :,t:'or or an approval of , any,, v i o'l a.t•i on
of .pr ov i s f o'ris Of the building Code or of
othe`►^1:0rd`inance' of the : °iuriWet 1un No permit oresuming to.'
{givra authvx;,ity: "to violate or: `cance the: provi: ions Of .thi's,
code : :shall he °va 1 i d
MANUFACTURERS IN'STALLA.TZON °. INSTRU'TION • R EOUIREC► ON SI i'E
FOR T HE BUI''LDIN(:3 .. IN'SPECTORS,' REVIEW
P 1 urnbi.ng perm; ts? sha 1 1 be obt'ained t hr uugh he 'Seatt'l e4g,ing
County Della r tment.of, Publ ic °H a,1 th Plumi,.,inq i 11 r'a
pet t:.r�
i n. t ed i'�r . at Jag en rncjud. n+g '; 11 ," ��s piping
7. E1ec ts sha 11 be obta ;.finedl. :.through the Washirlg,ton
State Y ')iv . i•-s1On of Labor and IndustrI`es and ''a.l l °`: electr::ica:l'
work `.w.iyl l '.be =inspected by that agency '5,248 - 6630)
8, Read i iVi \access i b 1 e, access .to roof mounted ',equipment is
PUBLIC WORKS
APPROVED E
C:ROUTE -F
u -'�w. <i'n^- ...F.; h7u.. s�,..,,..,"f. C':::' 1'.' Y.:^..>>F' C�trt,:;:!`y.f <iJr.Sf : ?.1✓s ^ „?t:;i
?avni4 (J)oyd. Copy
PLAN REVIEW / ROUTING SLIP
ACTIVITY NUMBER
PROJECT NAME
DEPARTMENT:
BUILDING DIVISION
EJ
REVIEWERS INITIAL
REVIEWERS INITIAL
CORRECTION DETERMINATION:
REVIEWERS INITIAL
M97 -0188
INNOVA — AC UNITS
FIRE PREVENTION i
STRUCTURAL Ej
DETERMINATION OF COMPLETENESS: (T,Th)
COMPLETE NOT COMPLETE L__!
COMMENTS
TUES /THIURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED E
ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.)
APPROVALS OR CORRECTIONS: (ten days)
DATE
APPROVED I I APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments)
DATE
APPROVED W/ CONDITIONS [II] NOT APPROVED (attach comments) 0
DATE
DUE DATE
DATE 12 -18 -97
PLANNING DIVISION
NOT APPLICABLE fl
1 -6 -98
PERMIT COORDINATOR 1
DUE DATE 12 -23 -97
DUE DATE
(Certification of occupancy required.
1( C)
*•kk *•k **k "h k** * *fi• *A *"•A* ** **•k *Ak *•k **A ** fi *k•k•k *4kkk* ***A *A * * *A*•A4**
ul,l'Y OF' TUKWILA YlA . 1R(lNSMTT
****.k a* k*"*** A• k* hA*kk• k* **"Ak:k'A * *A * *lek * * * *4sA*+4k.' *. *k *k•k *•kA *A.A *A *A*.
1 FANSM3:1• • Number. 89700699 Amount: 49.69 01/06/98 08:34
P'ayrnent " Methods CHECK Notation: IEC 3 INC I n i t : l3 LH
Permit • No M97 -0488 Type: 13-MECH MECHANICAL PERMIT
Parcel No: 092304 -9068
Site Address: 3315 5 116 ST
Total Fees: 77.19
This Payment; 49.69 Total ALL Pmts: 77.19
Balance: .00
k***• hk: 4tkk11fi• 44!1** 4*'' k4• j,* kA *A 4•*. A*. 1* .'**-**+4•A*•*0 fi414$iA71fi•lk•4•k1:•k.A.*
Account Code
000/345.830
000/322.100
Ue s.r. r^ i p t.i o n
PLAN, CHECK - NONRES
14EC'H( f4ICAL •- N0NIU S
Amount
9.94
39.75
k*** *4*kk.;t * * * *4 *k•k•kk*h *•A* *•A*** k*• kkk• AA*. k* 4• I., tkA *•A *Ak•kk *+4k*!;".t•k:k•t••k:,
ITY OF TUKWILA. WA (y`\ `I 4 ' `k TRANSMIT
Fk•kA.:tk *kk*Akkh.A *A•i•kA0 * *** klr * * \* *44k*,t*% *kA
TRANSMIT Number: lx97006 93 :Amount. 27.50 12/18/97 09:57
Payment Method: .CHICK Notation: IECs3„ INC :(nit: 13i•.H
Permit Not M97 -0188 Type: 13- 141:CH MECHANICAL PEUMIl
Parcel No: 092304• -9068
Site Address: 3313 S 116 sr
This. I'Ety "ment 27„50
,,.A$ A•$ #•kA* * n 3 •A• , t '•+•33)t** kof 4 #* *;tWA *a **** A *of* t *0k•kkAA *>>•A• **•* * *3•k
Account Code
000/345.830
000/322.100
Total Fee:
Total ALL Pmts:
Balance:
L'e5c,ription
PLAN CHECK -- NON!• :E5
MECHANICAL •- N0NI3IIS
21.:70
27.50
.00
Amount
5.50
22.00
6916.12/19 9717 TOTAL . 27.50
July 13, 1999
John Fitzpatrick
3325 South 116` Street
Tukwila, WA 98168
RE: Permit Status M97 -0188
3315 South 116 Street
Dear Mr. Fitzpatrick:
In reviewing our current permit files, it appears that your permit for the installation of (3) 20 ton
AC units issued on January 6, 1998 has not received a final inspection as of the date of this letter
by the City of Tukwila Building Division.
Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the
building official under the provision of this code shall expire by limitation and become null and
void if the building or work authorized by such permit is not commenced within 180 days from
the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, if a final inspection is not called for within ten (10) business days from the
date of this letter, the Permit Center will close your file and the work completed to date will be
considered non - complying and not in conformance with the Uniform Building Code and/or
Mechanical Code.
Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection.
Thank you for your cooperation in this matter.
Sincerely,
`�d1ie�e�
Brenda Holt
Permit Coordinator
City of Tukwila
Department of Community Development Steve Lancaster, Director
Xc: Permit File No. M97 -0188
Duane Griffin, Building Official
John W. Rants, Mayor
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 431 3665
I
or o ' ......Wtow.o........a.ntahisenagaylerna.fiwAr014...V114 , 1”.......1,11.1•044 , 04441,61rarel: •
•
a
CITY OF TUKVVILA
APPROVED
JAN 2 1993
F3UL INC;131VISION
, •
•
SEPARATE PERMIT
REQUIRED r"
o MECI-tg
TI ELECTP ,1,
PLUMBING
GAS PIPING
c1r OF TUKWILA
BUILDING DIVISION
(7,
• t ,k ;
( . 4 • •
• (t)
tU
Cu 0
,...•••■■■■•
RECEIVED
CITY OF TUKWILA
DEC 1 8 1997
PERMIT CENTER
Mir • 01 St
Equipment Schedule
Tag
Make
Model
CFM
Cooling in BTUs
Total Net
EER/SEER
OA CFM
V /Ph
AC 1,2,3
_ . Trane
TCD 240640A
2000
246,0001 232,000
8.71---
200
460/3
Seven day programmable thermostat w /night setback
Economizer on units 2000 CFM or more
CT
R
c)
m
n
00
& A :2 .
SYSTEM SIZING SUMMAR,,,.
System Name : Innova 12 -17 -97
Location : Seattle- Tacoma, Washington Block Load v2.12
Prepared By : Seattle Mechanical Page 1 of 2
*****************:************************ * * * * * * * * * * * * ** * * * * * * * * * * * * * * * **
TABLE 1. SIZING DATA -- COOLING
Total coil load = 713,926 BTU/hr Load occurs @ June 1900
Sensible coil load = 696,941 BTU /hr Outdoor Db/Wb = 75.5/ 62.5 F
Total zone sensible= 668,019 BTU /hr Coil Conditions:
Supply temperature = 45.9 F Entering Db/Wb = 72.1/ 56.3 F
Supply air (actual)= 24,000 CFM Leaving Db/Wb = 44.8/ 44.1 F
Supply air (std) = 23,667 CFM Apparatus dewpoint= 43.4 F
Ventilation air = 600 CFM Bypass factor = 0.050
Direct exhaust air = 0 CFM Resulting zone RH = 36.1 %
Reheat required = 0 BTU/hr
Floor area (sqft) = 15,000 Total coil load = 59.49 Ton
Overall U -value = 0.128 Sensible coil load = 58.08 Ton
Vent air CFM/sqft = 0.04 SQFT/Ton = 252.13
Vent air CFM /person = 20.00 Cooling BTU/hr /sqft = 47.60
Cooling CFM /sqft = 1.60
TABLE 2. SIZING DATA -- HEATING
System does not have heating capabilities.
TABLE 3. INPUT DATA -- WEATHER
City = Seattle- Tacoma
State = Washington
Data Source = ASHRAE 1%
Latitude = 47.5 deg.
Elevation = 386.0 ft
TABLE 4. INPUT DATA -- UVAC SYSTEM
.rornrn..nx�t s+.r e4• ru....Jr,ite r .W..'.rarwst40.117W M AfM110.4•P trMn .4akM4YW M/..s WAVIATVW741tT3PNh9tOWIV ; N xGAteltettAte.
Summer dry -bulb = 84.0 F
Coincident wet -bulb= 65.0 F
Daily Range = 22.0 F
Winter dry -bulb = 21.0 F
Atmos. Clear. Num. = 1.05
System Type : Cooling Only THERMOSTAT SETPOINTS
System Start 600 Cooling (Occ) : 72.0 F
Duration 14 hrs Cooling (Unocc) : 78.0 F
Heating : 70.0 F
SIZING SPECIFICATIONS FACTORS
Supply : 24,000 CFM Coil Bypass : 0.050
Ventilation 20.00 CFM /person Safety (Sens) : 0 %
Exhaust 0 CFM Safety (Latent) : 0 %
Heating Safety : 0 %
FAN RETURN AIR PLENUM : N
Configuration : Draw -Thru
Static Pressure : 1.50 in.
RECEIVED
CITY OF TUKWILA
DEC 1 81997
PERMIT CENTER
SYSTEM SIZING SUMMAR(
System Name : Innova 12 -17 -97
Location : Seattle- Tacoma, Washington Block Load v2.12
Prepared By Seattle Mechanical Page 2 of 2
* ** ************************************ * * * *** * * * * * * * * * * * * * * * * * * * * * * * ** 4
TABLE 5. TOP TEN COOLING COIL LOADS
Sensible Total Sensible Total
Time Ton Ton Time Ton Ton
1) June /1900 58.08 59.49
2) June /1800 57.93 59.34
3) July /1900 57.95 59.31
4) July /1800 57.81 59.16
5) June /1700 57.58 58.98
TABLE 6. ZONE SIZING DATA
Maximum • Design
Cooling Airflow Design
Sensible Rate Time
Zone Name (BTU /hr) (CFM)
Innova
668,019 24,000 @June 1900
6) July /1700 57.47 58.81
7) June /1600 57.04 58.42
8) May /1900 57.20 58.42
9) Aug/1900 57.05 58.38
10) Aug/1800 56.95 58.28
Maximum Design
Heating Flow
Load Rate
S (BTU/hr) (CFM)
mqi- Dies
RECEIVED
CITY OF TUKWILA
DEC 1 81997
PERMIT CENTER
From: Doug Campbell To: Faic#2084313885
City of Tukwila
Attn.: Building Official
Re: Permit Number M97 -0188
To:
Dear Sir or Madam,
Date: 1/2/98. Time: 10:39:44
.SEATTLE MECHANICAL
899 W. Main St. • Auburn, WA 98001 • (253) 939 -9495
COMMii: LAITY
1/2/98 FJIMVELQ 'MENT
On Friday I spoke to the Tukwila Fire Dept. regarding the use of smoke detectors in the HVAC
equipment we will be installing. They explained that if there is line of site egress to the building
exterior from no more than 100 ft. at any point in the building, smoke deteotors"are not required.
I was asked to send a letter to you to place in the Permit File.
Please call if I need to do anything further with this amendment.
Doug Campbell
Page 1 of 1
Dear Sir:
City of Tukwila
Fire Department
Fire Department Review
Control #M97 -0188
Re : H.V.A.C. a t Innova - 3325 South 116th Street
The installation of wiring and equipment shall be in
�u��"^' rx; q��< sr`• v�;, Yrr.,. s�! �. �' .r +�an�s: -sst: r,
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. H.V.A.C. units rated at greater than 2,000 cfm require
auto - shutdown devices. These devices shall be separately
zoned in the alarm panel and local U.L. central station
supervision is required•. (City Ordinance #1742)
H.V.A.C. systems supplying air in excess of 2,000
cubic feet per minute to enclosed spaces within
buildings shall be equipped with an automatic shutoff.
Automatic shutoff shall be accomplished by
interrupting the power source of the air - moving
equipment upon detection of smoke in the main
supply -air duct served by such equipment. 'Smoke
detectors shall be labeled by an approved agency for
air -duct installation and shall be installed in
accordance with the manufacturer's installation
instructions. (UMC 608)
2. Duct smoke detectors shall be capable of being reset
from the alarm panel. (City Ordinance #1742)
• Remote indicator lights are required on all above
ceiling smoke detectors. (City Ordinance #1742)
3. In areas that are not continuously occupied, automatic
smoke detection shall be provided at each control unit(s)
location to provide notification of fire at that location.
(NFPA 1 -5.6)
John W Rants, Mayor
Thomas P. Keefe, Fire Chief
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 57.5-4439
n :5 ;: -Z `. iv/:Naha x.,;.. c r c n sl.W..Ye;t•EtSO StrAtiAIZO WXMCTIIVilk.O4 avrImorAdi h wo,
City of Tukwila
Fire Department
Page number 2
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
accordance with N.F.P.A. 70, Article 760, Fire
Protective Signaling Systems. (NFPA 72- 1- 5.5.4)
4. When the control panel is located inside a room, the
door to the room shall have a sign with one -inch letters
which reads "Fire Alarm" or "Fire Alarm Control ". (City
Ordinance #1742)
Dedicated fire alarm system circuit breaker(s) shall
be equipped with a mechanical lockout device. (NFPA
72 (1- 5.2.8.2))
5. All new fire alarm systems or modifications to
existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence
until a fire department permit has been obtained. (City
Ordinance #1742) (UFC 1001.3)
Contact The Tukwila Fire Prevention Bureau to witness all
required inspections and tests. (UFC 10.503) (City
Ordinance #1742)
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439
i dint
a t: .:
REGIST4RgD
CONW CONT:' SPECIALTY .
1 REGISTRATION . NUMBERir w n ; �
CCAACG: IECS* 044QL +,
EFFECTIVE DATE 11/13/1996
Signature
Issued by EPARTMENT OF LABOR AND INDUST