Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M97-0193 - NC MACHINERY
City of Tukwila C Community Development / Public Works • 6300 SouthcenterBoulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M97 -0193 Type: B -MECH Category: NRES Address: 16711 WEST VALLEY HY Location: Parcel #: 252304 -9010 Contractor License No: TENANT NC MACHINERY 16711 WEST VALLEY HY, TUKWILA WA 98188 OWNER NC MACHINERY CO 16711 WEST VALLEY HY, TUKWILA WA 98188 CONTACT LAURA NICHOLS 7707 DETROIT.SW,'`SEATTLE'WA 98106 UMC Edition: mit Center Authorized Si Permit Description: REPLACE ROOF TOP 6 TON AC /GAS HEAT FOR LIKE AND 25' GAS PIPE. Valuation Total Permit Fee: Status: PENDING Issued: Expires: (206) 431 -3670 Phone: 206 - 768 -3968 **************************,**********'****** * *, * * * * *,r * * * * * * * * * * * * * * * * * * * ** ,422.00 27.50 *********'**** * * * * * * * * * * * * * * * * * * * * * ** * * * * * ** .1:V-LiLnCi4044-44).4_4 Date I hereby, certify that I.have read and examined this permit and know: the same to,be true and correct. All provisions of. law and ordinances . governing:this work will be complied with,. whether specified herein; or not. The granting of _this permit does not pres.ume,to give authority to violate or cancel the provisions of any other state or local laws regulating construction o the performance of work. I am authorized. .to'`sign for and obtain this' b lding permit. Signature:_'- Date: 12)341q Title: [!',,(g,/,__ This permit shall become null and void if: the work is :.not commenced within 180 days from the date..of issuance, or . if the work i.s..suspended or abandoned for a period-:of 18p days from the last. inspection. Project Name/Tenant: }Kra 4/ Mr chin •e r `j (rem ote Aro cQur`Pn�lvrtt co� AKA Value of Constru on: . 19 .. Site Address: City State /Zip: /6'r// w, if4// Y -/ fit Y i x� u, A w 9 R/ Tax Parcel Number; c 12, () r_, — 0/�''1_o2 Property Owner: ij- -, -1c AS *.e,-,r-- ,-I-1 City State /Zip: Phone: z a 5 - . a ' ` a / - g0 & Fax #: Street Address: Contact Person: A.A(.ra /c.It rpMc- iDeTalb - MiIIeP Sprvi Phone: — ; 6 6 - -� 7 ,9 Street Address: City State /Zip: _Z72 De fRo Jam tt � /i° yt/fl- 9 fx/ g Fax #: 2Uln- z( 9 Contractor: P- ME Ce2-7 44z p e (5-17 Phone: Street Address: City State /Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: rrt /Y 5 cc77 , City State /Zip: Phone: Fax #: Street Address: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED:(TO BE FILLED OUT BY APPLICANT) ` I Description of work to be done: '.. ..e / // ,t . , _ - - , ? 5 - 'e•/3-; Cr.7r , "g , % " * 41 r are ... e_ f . Will there be storage of flammable /combustible hazardous material in the building? ❑ yes Ga Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes n pi!Ilrhnd/Docks n Commercial Reroof ❑ Demolition ❑ Fence 71 Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE. BILLINGS TO: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby CITY OF TWKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 FO', STAFF USE ONLY Project Number: Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. WATER METER DEPOSIT /REFUND BILLING: Name: Address: Date applicafi ( accte MISCPMT.DOC 7/11/96 APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer It: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Date applicat ©. 6 Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Applicafi. fa ti by: (Initials) BUILDING OWNER OR AUTHORIZED AGENT: SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2 :1 PERMIT REVIEW Submit checklist No: M -9 Signature: , ? � , c //7r61/4- Date: / _ /2 _ Commercial Tenant Improvement Permit 0 Print name' ' ,f Phone: Commercial Reroof Submit checklist No: M -6 Fax #: �c762 Address: Submit checklist No: M -3 M -3a City /State /Zip: Submit checklist No: M -9 0 Land Aitering/Grading /Preloads. 0 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2 :1 PERMIT REVIEW Submit checklist No: M -9 0 Antennas /Satellite Dishes Submit checklist ` No: M -1 d Awnings /Canopies - No signage Commercial Tenant Improvement Permit 0 Bulkhead /Dock Submit checklist No: M -10 0 Commercial Reroof Submit checklist No: M -6 0 Demolition Submit checklist No: M -3 M -3a 0 Fences - Over 6 feet in Height Submit checklist No: M -9 0 Land Aitering/Grading /Preloads. Submit checklist No: M -2 0 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 cR Mechanical (Residential & Commercial) Submit checklist No M -8, Residential only - H- 6,_H -16 0 Miscellaneous Public Works Permits Submit checklist No: H -9 0 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist . No: M -5 o Moving Oversized Load /Hauling Submit checklist No: M -5 0 Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 0 Retaining Walls - Over 4 feet in height Submit checklist No: M -1 0 Temporary Facilities Submit checklist No: M -7 0 Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 0 Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PE • T APPLICATIONS MUST BE. SUBM D WITH THE FOLLOWING: ➢ A L BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BIJ tDING SITE PLANS UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 4 MISCPMT.DOG ?7,11/96 r 44 ''e • „j or .,U WEST VALLEY HY Permit. Nip: ' Address: 16711 Suite: Tenant: .:NC- MACHINERY Type.: B -MECH M97 -01 Status: PENDING App l:i ed: 12/22/19.9 Parcel #: 252304. -90101 Issued: *• k• k'- k: k'• k. k" k*• A** * *'k *k AA*'•k *** *k * * * *•k* 1 4**'• k'• k• k*'• k• k• k• A• A*-A* k•b:k*k•k•M ***•k*.* * **•k *** * ** Permit - Conditions: 1 No changes wi1.1 be made to the plans unless approved by the Architect or Engineer and the : LIkWi;1a Building Division. Al , 1 '.permits, inspect ion-, record , : d,;�' anappr °oved plans shall be available at the job site prior to the'` stert aiiy con - struct'ion. These `d.ocumen.ts. are to. :be maintained and avai l - abie unti 1 final" inspection: approval < is granted a.. Al 1 'construction to :, be :done' in t'onformance with approved Plans: and r,eq.uir emerits':of the Uniform B u l l d.ing Code 0994 Edition) a5; a mended:',.'Uniform'' Meehan i .Code: (1994 .Editi'o and Washin Energy. Co . (1994 Edition) 4. Electri'ca1 permits shall be abta`i"ned through , Wesh ; ington, State ,(ft v i s i on of `Labor and Industries and all electrical , work ;will be'' inspected .b:y •that agency (248 - 6630) S Automatic shut -off for :smoke,c.ontrol is required for,air�. moving s` systems supplying air : ;in excess of 2000 cf n .. UBC:' 6 6. ,MANUFACTURERS .INSTALLATION-INSTRUCTIONS REQUIRED ON SITE FOR;', -T 1E BUILDING INSPE :REVIEW, : :, : 7', Va1�1 i ty of Permit. • The: Issuance of !a permit or approval plan:, a p,ecrific'etions, :,,and ompu'tat` ion ti sha11 not be: con st ue'd to be a per;m1t for or an approval oF, any violation of arr of-the. prov is i vns of tiie building code or of env Other's ordinance of :,tile ,f ur isdict ,. No: }permi presumin'g:�:�,C g.ive .author q ty;. to v i t� ol e .or cancel the "'provisions of this': code t 5 { .ha 11 ';:b'e' .valid . Penn- CxrJ. 614. c PLAN REVIEW / ROUTI SLIP ACTIVITY NUMBER M97 -0193 PROJECT NAME N.C. MACHINERY EPteTMENT: UILDING DIVISION El FIRE PREVENTION i --. ! PLANN IVISION a LIC ORKS STR C� fl PERMIT COORDINATOR III 1 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE IS NOT COMPLETE El COMMENTS TUES /TTJURS ROUTING: PLEASE ROUTE fl NO FURTHER REVIEW REQUIRED fl ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED ( I APPROVED W/ CONDITIONS C:ROUTE -F DATE APPROVED fl APPROVED W/ CONDITIONS l l NOT APPROVED (attach comments) 0 DATE DATE 12 -22 -97 REVIEWERS INITIAL DATE DUE DATE 12 -23 -97 NOT APPLICABLE fl DUE DATE 1 -6 -98 DUE DATE NOT APPROVED (attach comments) LJ (Certification of occupancy required. ) Project: Type of i pecti• I Ad d e s rt u,n 1 w vial Date c alla.: to _ . .- _8 Special instructions: . Date wanted: .. h Z3 a.m. •.m. Requester,,. v. tfb` J•' �C „... ... .a MIGi WeIT.�.M5'. WA.'�l" : !4 1 N 41 ITIO 4..YT...(: , I' INSPECTION RECORD , Retain a copy with perm INSPECTIO NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 9818 p ] Approved per applicable codes. COMMENTS: 1 Receipt No.: (14q PERMIT NO. 431 -3670 Corrections required prior to approval. Inspector: Date: z / j $42, + INSPEN E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: Type of inspectio ro Address: 1 U 1 t i' W (b- ! Date called: I) CZb •tL' V ), Cfrt - All (I/( -v Aft- . .2"' PV A..y.,c Ra.A -vr %►-IG C,a t c 4 S. �tt `r't a-=C 1. r'' - �' ti■ 0 1 7 - c a- 1t p i 2G Vi" Requester: S.4rni C.._ Yt•et.A c i Phone No.: 7 GZ-- / Asa Project: cv\ Type of inspectio ro Address: 1 U 1 t i' W (b- ! Date called: ` t Special instructions: �� c)I'" Date wanted: �tt `r't r t) il a.m. �pm. Requester: t,�-e. ems Phone No.: 7 GZ-- / Asa INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Receipt No.: INSPECTION RECORD Retain a copy with perm YYIq - C11g3 , PERMIT NO. (206) 431 -3670 �1 Corrections required prior to approval. Date: /.4 1(() ) $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: c t A K � / " b164 Type of inspection: A:" e� 7 Address: Date called: /� Special i s ructions: Date wanted: / `2'5 Requester: Phone No.: COMMENTS: Inspector: Date: 11 INSP2C'RQIV NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. i-`7// q// r4m /. W ell.1411 $42.00 REINSPECT! N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [Receipt No.: INSPECTION RECORD� Retain a copy with pern&j se.... a. r PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: Project: N C A ((. 2. y Type of inspection: t-- sp A-4 -1.- -4 Ai/ Ad dress• Date called: iltOM Special instructions: G .-( r Date wanted: co? a.m. 1 Requester: - IKU D Phone N 00`0e%52.., 1010 - Elifio INSPECTION, RECORD Retain a copy with per INSPE(;rION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: I Inspector: Date: M 1 9 3 PERMIT NO. (206) 431 -3670 Approved per applicable codes. [X Corrections required prior to approval. Date J` _96 1 S42.0 REINSPECTI FEE REQUIRED. Prior to inspection, fee must be ' aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. • -, ....r.7 1.- ,1 - ^ - ,7,7, , , - ,T79Tryxv, 0 7:447:57 6.4 7.7n1,74 - 74, 1 "; . y.V:ZZITTN47,4,7T' " 1-• 3 ,41' • kdi '`V .1 ,• • project Name I 11 \(•L. T) e/74/1\it-le"?/ Address (I i/ //c.) (P37 V1/ 7 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM A I I11 6 7 . /e_ //i/- Approved with correction notice issued T.F.D. Form F.P. 85 John W. Rants, Mayor Permit No. / Suite # vAme3 Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575•404 • Fax (206) 57•4439 APR -20 -1998 10:00 GM( 'ONSULTANTS AAt) AAee AA 206 762 2057 P.01 2066$ 39 P.01 Gxi]C. COI+TSL3x.T,A,Iq'X'.1% Civil & Structural Engineering services 810 Third Ave, suite 624, Seattle, WA. 98104. Tel. (206) 682 -2138, fax. (206) 682-2139 2- TO: COMPANY PI AT NTIOM Ft. c rrb. " 1 7 � Ez. — s g 0 ) FROM PROo?ECT NAME/NO. NUMBER OF PAGES TRANSMITTING (INCLUDING THIS COVER SHEET) MESSAGE /COMMENTS : jz,. o gz- Alorb rirglicoGE PLEASE NOTIFY US IMMEDIATELY IF YOU DO NOT RECEIVE ALL PAGES CLEARLY. V Hard Copy To Follow. TELEFAX__TBAN j GHI. CONSULTANTS Signed : 97-o/t3 rol 10:54 [TX /RX NO 8804] a001 ' APR -20 -1998 10:00 February 5, 1998 MacDonald - Miller Service Inc. 7707 Detroit Avenue SW Seattle, WA. 98106 Fax: (206) 768 -3901 Tel: (206) 767 -3969 GHL '' ONSULTANTS AAfi AAee AA 206 762 2057 P.02 Attention : Mr. Scott Groff/ Mr. Jay Madden/ Ms. Laura Nichols 2066029 P.02 GHQ, CONSULTANTS Civil & Structural Engineering Services 810 Third Ave, Suite 62A, Seattle, WA. 98104. Tel. (206) 6822138, Fax. C206) 682 -2139 Subject : Revisions to Structural framing to clear sprinkler at the Air Condition Equipment (ACE) Support on hoof. 16711 West Valley Highway, Tukwila, Washington. As per your request and authorization we have inspected the installation of the structural framing for ACE support at 16711 West Valley Highway in. Tukwila. We have found that the 2x8 joists which support the ACE on the east end need to be notched to clear a sprinkler head on the north end and a conduit on the south end. Especially the notch required at the sprinkler head significantly undermines the capacity of the 2x8 joists that are there at present. We are therefore recomtnending adding 2 -2x6 joists on the east side of the 2x8's and bolting together the new 2x6's with the existing 2x8's. The attached sketches show a Section Y showing the notches and bolt spacing for seven bolts required to make the connection. Section Z shows the bolting of 2 -2x6's with 2- 2x8's. The bolts shall conform to ASTM A307 specifications and shall be one half inch in diameter and shall be installed with a corresponding nut and washers. The 2x6 joists shall be of Douglas Fir -Larch Select with values of Fb Q 1450 psi and Fv = 95 pal. Should you have any questions please give me a call. Sincerely, GM. Consultants nrriA rte- -' - tLM Guma Haire -Leul, P.E. Principal Enclosures: 2 -Pages of Sketches. 04/20/98 MON 10:54 (TX /RX NO 8804] 12002 APR -20 -1998 10:01 AAO AA66 AA OHL ONSULTANTS CHL CONSULTANTS Civil & Structural Engineering TITLE MAO NAt.it* - 14rt.1.EE F'g07idi- 4r • 14 -i,l 206 762 2057 P.03 20668Z"'39 P.03 Sheet No. 2 Job No. 1 g Lt~t SUBJECT Pooh 2A i& 7 o 2 A/c ENV airr boTM LS MADE.BY G-H DATE, )4 ! MOT/ CHECKED BY DATE 4. 4 � N a h 0: 1"C t4 • V I V im " 04/20/98 MON 10:54 [TX /RX NO 88041 Z003 APR-20-199B 10:02 aHL CONSULTANTS Civil & Structural Engincerint SUBJECT gl MADE BY c I • • • ••• • • i GM( 'ONSULTANTS ki; ••••• memo Imeio AM 446 AA 206 762 2057 P.04 TITLE Motc --AQ31- u1)) Ki• t!4i.Lffilt 644y...Tuvviat. o/ Ac ER wi /4)1.-5. DATE . r....1NrAII• CHECKED BY DATE • • ex' • • 20669:( 39 Sheet No.AL of Job No. ; t • • I, 7 • •• • P. 94 •.■ ••••••• j -3 1-- U3 A TOTAL P.04 04/20/98 MON 10:54 [TX/RX NO 88041 Q004 MESSAGE /COMMENTS : l GAL oCQNSi.TX..T.". ITh Civil & Structural. Engineering Services 810 Third Ave, Suits 624, Seattle, WA. 98104. Tel. (206) 6R2 -2138, Pax. (206) 682 -2139 • GHL CONSULTANTS ► ) ) DATE : TO: COMPANY MAC i4- - \/) )1-1-G2 ATTENTION LAv - is1 1C o FAX NO. FROM : a t e O )4.01)-E-LeVL � PROJECT NAME /NO. NUMBER OF PAGES TRANSMITTING (INCLUDING THIS COVER SHEET) e �. L€ ey iz) Hord Copy To Follow. 4 XELEFAX TRANSMIYA&. RM 2066822139 r �_ P.01 PLEASE NOTIFY US IMMEDIATELY IF YOU DO NOT RECEIVE ALL PAGES CLEARLY. CITY OF TUKWII.A APROVC.D DEC 301997 AS NC fED BUILDING; DIVISION GHL CONSULTANTS Signed : RECEIVED CITY OF TUKWILA DEC 2 21997 PERMIT CENTER mslotct3 December 19, 1997 MacDonald - Miller Service Inc. 7707 Detroit Avenue SW Seattle, WA. 98106 Fax: (206) 768 -3901 Tel: (206) 767 -3969 GHL CONSULTANTS 2066822139 GHL CONSULTANTS Civil & Structural Engineering Services 810 Third Ave, Suite 624, Seattle, WA. 98104. Tel. (206) 682 -2138, Fax. (206) 682 -2139 P.02 Attention : Mr. Scott Groff/ Mr. Jay Madden/ Ms. Laura Nichols Subject : Structural Design Sketches For Air Condition Equipment Support on Roof. 16711 West Valley Highway, Tukwila, Washington. As per your request and authorization we have completed our structural review of the existing roof framing of the building at 16711 West Valley Highway in Tukwila to determine the adequacy of the existing roof framing or to design structural strengthening to support a new air conditioning equipment to be installed on the roof. We summarize our findings and conclusions as follows : We find the existing roof framing less than adequate to support the load that it is supposed to have been designed for according to the plans. The existing 2 x 4 joists spanning 8 Ft. are less than adequate to support the 25 psf. design snow load shown on the plans and is also required by code in this Puget Sound region, It definitely needs to be upgraded to code standards. We therefore find the existing framing unsuited to support the additional air conditioning unit without a structural strengthening design. 2. Our structural strengthening of the roof framing for the support of the new air conditioning equipment is shown in the sketches that are attached herewith. For the equipment weight we used 1003 pounds as was given to us by Ms. Laura Nichols. Our design basically introduces 2 x 6 members to be installed under the existing 2 x 4 members to support the additional load and transfer it to the 4 x 12 beams, The design calls for single 2 x 6 joists in the east/west direction and double 2 x 6 joists spanning 8 Ft. in the north/south direction between the existing 4 x 12 beams. All the new timber shall be of Douglas Fir -Larch Select with values of Fb 1450 psi and Fv = 95 psi. RECEIVED CITY OF TUKwILA DEC 2 21 PERMIT CENTER f.IJ444.4 k4.1%NM1 114,WitfrOs 4.04S.`6dMAi41.naW0MPI 47 MacDonald Miller 12/19/97 Sincerely, GM, Consul . nts '��1L,iryKTYA if ma Ila"e-Leul, P.E. Principal GHL CONSULTANTS. Should you have any questions please give me a call. GM- Consultants 2066822139 p. 03 PERMIT. CENTER 3. We believe the new 2 x 6 members can be installed snug fit under the existing 2 x 4 members from inside with minimal disruption to the existing structural system. RECEIVED CITY OF TUKWILA DEC 2 21997 • I- LN7►K Te Awn.* r, r, GHL CONSULTANTS GRL CONSULTANTS Civil & Structural Engineering TITLE EzoTec.N A 1G 1)) YV• YA s-t. > I ' - .'wi' - SUBJECT 'pp .4 c fop .- 1 : TA) 2.5 MADE BY G44- DATE • 4 (CHECKED BY DATE gc4 F't*Amint ... Dc7.41L. ,. • 2066822139 Sheet No. of Job No. Puy .4 OF ,4R1 fog )> Ys.44 .4)G vnorr m ix iALL P.04 RECEIVED CITY OF TUKWILA DEC 221997 PERMIT CENTER n Sheet No, 2 of Job No. TITLE MAC. ko NAL.ta - Mf1..t.E>` ? ?t r!~ < AT /OH t Wi44 GI-IL CONSULTANTS Civil & Structural Engincering SUBJECT ?O0P 01101$61 6. - 2 ,d)4 R W» ir7 r bFTA) t MADE BY_ CT-H t✓ GHL CONSULTANTS DATE l � ig)77 CHECKED 13Y 2066822139 DATE p.05 4 r -- • ti N ct " rt RECEIVED CITY OF TUKWILA DEC 221997 PERMIT CENTER h GAIL CONSULTANTS Civil & Structural !Engineering TITLE SUBJECT GHL CONSULTANTS J 4 N Lh mare F 2A ■iS MADE BY t3 DATE • 2066822139 Sheet No. 3 of Job No. ec hi) W VALL.e( IY TWKW)1„4 Fags ,4 c EIMPMEr4T t ) 211$) 9 7 CHECKED BY DATE v. N 'z P. 06 RECEIVED CITY OF TUKWILA DEC 2 21997 PERMIT CENTER a • GHL CONSULTANTS Civil & Structural Engineering TITLE A . ONA ALL6 &elec. SUBJECT MADE BY X4 DATE 1 4 GHL CONSULTANTS &Nir E IA_ 705) LS a�)�7 CHECKED BY 47ra Y11. Vw Lt.E.Y )4w; — "T►1Kw11.,14. 4 x N N op h Sheet No. 4 of Job No. DATE P_ 07 RECEIVED CITY OF TUKWILA DEC 221997 PERMIT CENTER CITY OF TUKWILA, WA TRANSMIT TRANSMIT Number: R9700695 Amount: 27.50 12/22/97 10:25 'Payment Method:. CHECK Notation: MACDONALD/MILLER Init: BLH ' -Permit' NotM97-0193 Type: 13-MECH MECHANICAL PERMIT Parcel No: 252304-9010 Site*Addreis: i6711 WEST VALLEY NY Thia Payment 27.50 . . Account Code . Description Amount 000/345.030 PLAN CHECK.- NONRES 5.50 000/322.100 MECHANICAL - NONRES 22.00 Total Fees: 27.50 Total ALL Pmts: • 27.50 Balance: .00 • StATTLE DEPARTMENT OF LABOR AND INDUSTRIES _;, PHIS CERTIFIES THAT THE PgRSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A ,+�;. •((y ^ • . *1' .�4, yL .1' 'Y J♦' ^ . ¢nSS$•i ..t.:1� `', " ` .. t� _ • . J• .,e�� \l / /illN /NN / / / /lN % /✓• / /)/ N//✓.%/ j ( //Y /N %/Wf•Y /llYi�N��t.N'Nlr�iN N/ il���J i�N��iv' �N/ 5A/ �%✓N /i����J /! / % % / /N/' % { /: / /(Y /� /NIJ /ININ //: / / /l /% N!� y EZPIR 47,;//99 ,- z z i g //0C, 704) so/97 PACKAGED GAS /ELEC AIR CONDITIONING UNIT SCHEDULE UNIT NO. AREA SERVED YORK MODEL NOM TONS GAS HEAT MBH CFM ESP FAN HP TA. CFM EER ELECTRICAL WT LBS AFUE /SEER NOTES INPUT OUTPUT VOLT /PH MCA AC -3 OFFICE AREA DCG072 -N079 6 100.01 79..0 2400 0.35 1.5 400 9.0 208/230 3 PH '.34.0 1003 80.5/80.8 1 -7 NOTES 11. POWER WIRING AND DISCONNECTS BY OTHERS 2I CONTROLS AND CONTROL WIRING BY MMS 3i. NEW ' DA'* PROGRAUABLE LOW VOLTAGE HONEYWELL T T -STAT WITH 07300A1018 SUB -BASE "r FACTOR, SUPPLIED CURB 5) FACTORY SUPPLIED ECONOMIZER. MIN OSA A06 CFM 6). INSTALL NEW SMOKE DETECTOR PER ' CODE SET £< BRACE NEW UNITS PER STATE AND LOCAL. CODES Mc?i orf! DEMO,.EXIST:'C UNIT SLEEPERS. 0 CURB 1 1/2' EXIST, / -ELECT 200 3 PH r ELEC 1 0, 30 -3 °H' TRANSFORMER hVA 75 1 / r \'L�JI'`,- 'j- /',J(/ REMUUE w REPLACE EOUIP. LIKE FOR Lln INSTAL_. NEW UNIT #3 ON NEW FACTORY CURB LCI.ATE OVER EXIST, DUCT DROPS EX'ST'G GAS REG 5 TO 8 1/2" WC DUCT DEMO CAS LINE AS SAOWN 1 /2" EXIST, FIELD DETAIL NEW DUCT TRANS CONN TO ExIST'G DUCT REPLACE EXIT r, T -STAT WrTH NEW COMBUSTION AIR INLET NEW COND PIPE TO EXISTU ROOF DRAIN , ELO DETAL FILE COPY plc._; r;,, cuthcrize the vio at UU a__F,:_d, code cr ordinance. Receipt of contractor's cape 7P�y� • Permit No. e , 1 CITY OF TUKWILA APPROVED DEC 30199 AS N;_.,_ BL:ILLING b A,LV .J Civr�f�;J SEPARATE PERMIT PEQIJIRED FOR: ❑ MECHA": DL REGET� ILA CITP OF Rp2QOr LAN -- AC BEG 2 2 1937 ��iDD PERMIT CENTER MacDonald Miller Company, Inc. 7717 Detroit Ave. S.W. Seattle, Wa 98106 -1903 Phone: (208) 763 -9400 Fox: (206) 767 -6773 Wcsh Llc No 223- 01- MA -CD -0M -24819 NC MACHINERY 16711 W. VALLEY HWY TUKWILA, WA 98188 PARTIAL 1ST FLOOR AND ROOF PLAN ` -HVAC- ENGINEER: LLN CHECKED BY JAI DRAFTER: LLN ISSUE DATE: ISSUED FOR CONSTRUCTION M -1 LAST REVISED: 12- 18-97 DATE PLOTTED: 12 -16-97 CAD REFERENCE: NCWCHINERY DRAWING NUMBER: SC -0404 SHEET NUMBER: