Loading...
HomeMy WebLinkAboutPermit M96-0013 - LINDAL CEDAR HOMES' Li M1)•& captici {}om mqb - aoI 3 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M96 -0013 Type: B- MECHAN Category: NRES Address: 10411 EMPIRE WY S Location: Parcel #: 032304 -9213 Contractor License No: MACDOMS147MN MECHANICAL PERMIT Permit Descri`pt1onc. INSTALL.TWO ROOFTOP' EXHAUST`FANS. UMC Edition: 1994 Valuation: Total Permit Fee: (206) 431-3670 Status: ISSUED Issued: 02/01/1996 Expires: 07/30/1996 TENANT LINDAL CEDAR HOMES 10411 EMPIRE WY S, TUKWILA, WA OWNER LINDAL CEDAR HOMES INC 4300 S 104TH PL, PO BOX ; 24426,..SEATTLE WA 98124 CONTRACTOR MACDONALD MILLER SERVICE INC .:. <' Phone: 206 767 -7995 7707 DETROIT S.W., SEATTLE, WA 98106 JOHN LAPHAM Phone: 206 768 -3932 7707 DETROIT AVENUE S.W. , SEATTLE, WA 98106 .. k * * * * * * * * * * * * * **•k * ** 6,500.00 51.25 ******* k*** * * * * * * * * * * * * * * * * * *•k * * * ** *tilt * * * **'*k * * * *'k ** atra Permit Center. Authorized Signature Signature: ;' D a t e I hereby I have read and' examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will, be complied with, whether specified herein or not The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local 'laws .regulating construction or the performance of work. I am authorized to sign for and obtain this!-.buildi g permit. Date:�,f6 Print Name: .2{!L_ p.t-1 TI This permit shall become null and void -'if the work is not commenced within 180 days from the date of .issuance, or if....the work is suspended or abandoned for a period of 180 days from'the last inspection. Address: 10411 'EMPIRE 'WY S Suite: Tenant : ': LINDAL; CEDAR .HOMES B- MIECHAN Parcel #: 032304` -9213: k k - :k• •k 'k k * •k 'k k •k 'k *4 'k •k k : 1( . * •k • k k * * k Permit Conditions: 1..',' No changes wi l 1 be made to j t,n° ...l.ans„`c 7pI,s.approved by the Architect or Engineer ^a;nd1�. TuF:wi Bul H.�l'fl.4. 2 All permits. insp. "c� i`'aii' and approV41414n4s ;hail be available at tJ 0i$,oh t p , i;ar to At he sta 10 of a►f`',` N struct ion. r?re e doc sK ar 1, .„,t.oy'be ,inain a lad anal0 .vaiI - a Le unti l i`,ndl In ;pe:ct:.i:on approval is g n N `'� 3 All: const �.'iota t r, i one eATV'tiirn ` 'or m an,ce 44 t.,I poi "o '' plans an e q ii r t ie is pf • l 1 "orm Bu 1 I Li,p9 � "z' 1 9`f'. Edition's i ' al mad4g, Url i form qj e Vice] Code "(.199 • E� i . i e and Wa - .gton _`tatlEnerg ( ON Edition ` 4. Valid of ermiton' Thad t tl.nce of 'a permit or ,:api.r p' Ian ; spelticats' ons,,:All d comput;a'tion; sha11 not ;die�ltQ ,�-' . tr,u ;,d�to .pb a perm i t -t: r, orpin appx3,ova I of , any .via lat: of ..� t.;v of the prov i s i onsV- ot,t;i e bu i,i d l ng code or of ' oth an r 4 e " e' t~ ' j >, sl q t` No,,permit p resumi =ng'�o 't 8 r or�'�i n�rnc of h.� * ur i s .i t i art _ :,. F, � give ;authority. to •...vio late ' ; ;c: {rjae.l. ? s code sha 11 be : �,va:l :`i.d ''., "t� +'�! F '-,' ' .fr- ` I ii. F: �. 4 5. MAN =Fy CTUR.ERS .,INSTALLATION INS c S °' °N l � A . M. �TION.�...REr]UIREG t N YTE ' FOR , i THL B. ILnINB `'IN3PELTOP R VIEW.; ; °. , 4 t:; , ? 6. Ele .1 ,.lr,., mit... "iia�l 1r ble�,.o t hrough the Wash= ington#° State D i ony °of Labor .' and: In :4- e;r..,eii a;,l. e1ecte,,'i ca�l` / 'fig wor W.i M Lie i0pected by that a � tai icy ,f C24 '3•- '6630) i�.;y , ..,n,. R. 7 . A , i , � WV ,,' rte` 0 x a i rt} e CITY OF TUKWILA Permit Nor M96 -0013 Status: ISSUED'. Appl ied: 01/26/1996 Issued: 02/.01/1996 k k •k • * - k • k • k k k •k k •k • •k • ' • ' M ' k'k 'k k ' • • ' k 'k k • k ' k • k •k ' k ' ' k k :k DEPARTMENT " DATE IN DATE . APPROVED 1-7-51- ��' {iv. GROUTED) REQUIREMENTS / COMMENTS CONSULTANT: Date Sent - Date Approved - DATE NOTIFIED BUILDING - initial review (` w qv F=IRE PROTECTION: U Sprinklers (J Detectors ON /A U FIRE FIRE DEPT. LETTER DATED: INSPECTOR: INIT: L. ? PLANNING ZONING: !BAR/LAND USE CONDITIONS? Li ves UNo SCREENING REQUIRED? O Yes Q No - — - - - -- INIT: REFERENCE FILE NOS.: L_.J GI HER .._ __.. INIT: BUILDING - fir iai review 1� 1- q UMC EDITION (year): 199+ ' INIT: .4 A >< BUILDING OFFICIAL 1--1 -3(4 __ . UNIT: -'h AMOUNT OWING: 4,51.as CONTACTED CI SUITE NO. DATE NOTIFIED _J-5)-q. BY: ( ( 13Y (init.) "- - - i' ; ' 2.-6 2nd NOTIFICATION 3RD NOTIFICATION BY: (init.) PROJECT NAME SITE ADDRESS SUITE NO. PLAN CHECK NUMBER mC4 (o 0013 CITY OF TUKWIL. ... Department of Community Development – Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking ch:,rt completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED 01/07/93 SITE ADDRESS I % L1 l I ,/ y L ujSUITE # 10 A I VALUE F CONSTRUCTION - $ PROJECT NAME/TENANT L..I L_ C Dv Z How e3 ASSESSOR ACCOUNT # C3Z 3C 4 --9? 1 —0 TYPE OF WORK: MNew /Addition 0 Modifications 0 Repair Q Other: DESCRIBE WORK TO BE DONE: TYPE .:.::.RAT NG /SIZE'. NUMBER OF UNITS _ _ -HVkO 5 F v r P 1 C _r-A-� ADDRESS 6 6cz=�_ 0C rV�' C CITY/ZIP CONTACT PERSON ( BUILDING USE (office, warehouse, etc.) 1 Jl.) R-- t `e PHONE NATURE OF BUSINESS: ‘40t-le \e .0 It-t>.--. WILL THERE BE A CHANGE IN USE? 0 Yes IF YES, EXPLAIN: WILL THERE B TORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? IF YES, EXPL� No 0 Yes I HEREBY CERTIFY THAT I HAVE R READ AND EXAMINED THIS APPLICATION AND KNOW T THE SAME TO BE TRUE BUILDING OWNER S SI , �TURE � PRI �T NAM 1 1�� LAP tAw-� P ADDRESS 6 6cz=�_ 0C rV�' C CITY/ZIP CONTACT PERSON ( ( £ \ P PHONE !PHONE 7 � +C �� ADDRESS 42,00 ( IC P L. sc= -( Lea- ZIP q �I� U CONTRACTOR tyc. ,��14.gyp r'J ( ,_►.- p �.x- z l IC.S co , PHONE 7� y �z ADDRESS 7 -T0 -7 lit-. SIT f TU(� . ,ll.) , ZIP �`StUk� WA. ST. CONTRACTOR'S LICENSE # Ht4cI::0M .5147 (Li i EXP. DATE_ (� cicl DESCRIPTION AMOUNT RCPT # DATE BASIC PERMIT FEE $15.00 UNIT(S) FEE PLAN CHECK FEE OTHER: TOTAL - CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 ( 206) 431 -3670 PLAN CHECK NUMBER (0 APPLICATION MUST BE FILLED OUT COMPLETELY MECHAIt,CAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architecVengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED a L2 C UO DATE APPLICATION EXPIRES 1 - c{(n 01/20/93 DESCRIPTION AMOUNT RCPT # DATE BASIC PERMIT FEE $15.00 UNIT(S) FEE PLAN CHECK FEE OTHER: TOTAL - CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 ( 206) 431 -3670 PLAN CHECK NUMBER (0 APPLICATION MUST BE FILLED OUT COMPLETELY MECHAIt,CAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architecVengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED a L2 C UO DATE APPLICATION EXPIRES 1 - c{(n 01/20/93 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 ( 206) 431 -3670 PLAN CHECK NUMBER (0 APPLICATION MUST BE FILLED OUT COMPLETELY MECHAIt,CAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architecVengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED a L2 C UO DATE APPLICATION EXPIRES 1 - c{(n 01/20/93 SUE6/IITTAL CHECK6ST r MECHANICAL 1 1 Completed mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. 'A * r: ts ksl,* k 11+ k• kk* si *•** * *•k* *• *r�tit�tstA * * *,t *k, 114 *.k.A *A *;4 *:4•k **k * * *4 * T'f Y )F TUKNILA. WA ' r - TRANSMIT A *k * . * 404rsti* * i6 k * *A A * "vi.i Ad•CW: ,tri A M * k,t**o*A*.Ah*k*s4.k+ *k•A!r*A* t.Rr�tlSMT'f Nurnbc�r: ;�r�0O3:iCi larnaiiryt: �ii.'?�i. 0"./01/:� / P vrerrt :Mebhcde CHECK Ncrtatiart. MACDONALD MILLER Init: SL.FI Permit No: M96-0013 Type: fl MECHi1N MECHANICAL PERMIT Parcel N,o: 032304-5213 Site Address: 10411 EMPIRE WY ;i Total feest Ti+4 i s Payment 51.25 Total ALL Prtrts: Valance: *** A** k:* A A * A*A***+ 41v,4 *• * *'Ae4 *•*4 *'4k**s1 ** * **0*A Account Code Description 200/345.1330 PLAN CHECK. HCNRES 000 /322.100 MECHANICAL •- N0NRES 51.25 51.25 .00 * * *A k4 **,** ** Amount 10.25 41.00 GENERA TOTAL: CHECK CHANGE 2211A000 51.2! 51.25 51.2E 0.00 15:57 COMMENTS: `' \ , 1 CAS.- 944t , - F T • s- r • ►o(- t,, ,_ el 217/97. i 0 t z . a & . a T J t t z 1/4 7 - 3 z 4 - c . A - i Lie<cs GO - qs11 n j I N Oh, - OPit,p 4A'1,1NU,v," ? ZS- 096 +L1ci. Z33 Special instructions: f , . Q I -c- �' ti. £V.c. lost APPR^. Date wanted: 2 /, n /« 7 p .m. Requester: A. Phone No.: CO O - '1317. Project / NoAi (....From - / Sri E Type of inspection: - t i./Pt— Address: /0‘,7-7 kr r LK-- Date called: Special instructions: f , . Q I -c- �' ti. £V.c. lost APPR^. Date wanted: 2 /, n /« 7 p .m. Requester: A. Phone No.: CO O - '1317. L [Inspector: 'Approved per applicable codes. Receipt No.: c INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: 2,1(0)47 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project:Li ein tg Nom s ype o ns 1 " I t j� L r� '`C2' � a � 1 Date Called: 4 -9 Special Instructions: 14I N Ft w..1 ' Zr Date Wanted: C - 1 O - 1 am pso. Requester. pAL 6 , n nD TIM to to - .i3I35 a nr.L`:3i.7r�Cic7iY5. SY� 0 Approved per applicable codes. I inspector: -t.P..InTo + SIC INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 rg Corrections qui ed prior to approval. COMMENTS: (2-6 NV r1- I rJ it f moko . rusMLV 1-- .s r r% t::Vc - /C4 CAL. k S VI L . 2 v„ tt%o. Dale: .-G, - q( D $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cal to schedule reinspection. r te. , .. i Jan 31, 1997 98106 RE: LINDAL CEDAR HOMES Dear Permit Holder: JOHN LAPHAM 7707 DETROIT AVENUE S.W. SEATTLE, WA �r City of Tukwila Sincerely, 1 6? ` _e Kelcie J. Peterson Permit Coordinator Department of Community Development ti F6 FI LE COP John W. Rants, Mayor Department of Community Development Steve Lancaster, Director Our records indicate that on Aug 04, 1996 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechanical Permit Number M96- 0013. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Aug 04, 1996. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 Post-er Fax Note 7671 Dal•yag 1:4 horn ... A P 11 arran=111111 I i i i i&tri II 011 I Fax I .- To ' 0 4 4. comio. ii a ma 9 . MORE AS43 ACCOUNT NUMBER; 0323•4-9213-0 TAXPAYER NAME: LINDAL CEDAR HOMES INC LEGAL DESCRIPTION - PACE I NOTE: READ LOT BLOCK PLAT: POR OF NE :1/4 OF SW 1/4 OAF TN .N 86-58-2S W ALC N LN OF 3D NE MON OF PSH 4 1 TN S 26-13-15 E E ALC SD N MON 153437 FT TAP NH LEGAL LINES LEFT TO RIGHT ACROSS SCREEN, BEG AT N)N OF N LN OF NW 1/4 31 NW 1/4 a NE 1/4 650494 FT TO TPOB ALO SD NE MON 372,28 FT TO N MCN BEARS S03-01-32 W FR TPOS TN N KING COUNTY DEPARTMENT OF ASSESSMENTS REAL PROPERTY LEGAL DESCRIPTION PROPERTY ADDRESS; 10411 EMPIRE WY S (ITRI SW SECT: 03 TWN: 23 RNG: 04 FOLIO: 020028- • SE 1/4 WITH W MON OF RMPIRE WAY ,S: TI-I CONT N'86-58-28 W 915,7 FT TO OF BOEING ACCESS RD TIl N:63-46-45 03-01-32 E 249489 FT '"0 TPOB. PAI11080!..S1 01/25/96 SUBAREA; 420-000 * * * END OF LEGAL DUCRIPTION-* ( NEXT ACCOUNT: 032304 9213 0 JUMP CODE; ENTER HELP END MENU CHAR HIST LEGL APPR BROW . PF-HELP MENUf 5 CD cr) cr) > 2 co 0 O u. C*4 lil 0 2 w. 0 :-*SISTERED,AS,. ^ 4 „•:••.v. v • . • ••• 44 It • 11 I' 4 ! I .; ' Y . 2 . • - ; 4 1 • : • • T" 0 •■■ di T flt SIGNATUR ,,,,,..3,...,...1:,,, 4 01X0Dpirierf;' /?SERVICE !INC"' ;•.i '' . i •• .1.'7Ci7 . perlicil•tAvi S 14 f'. • . ' ' . SEATTLE •WA :. 48106 • Data: I/31 ig (0 By: ISSUED !IA DEPA MENT OF LABOR AND INDUSTRIES MACDONALD-MILLER SERVICE, INC. 7707 Detroit Avenue S.W. »QJMEN CE RTA4ON 13. N-) \ P4--1■44 hereby certify that the above document, issued by the Department of Labor and Industries, is the official registration as provided by law for MacDonald-Miller Service, Inc. to perform as a Construction Contractor in the State of Washington. (License AVIACDOMS147MN) MACDONALD-MILLER SERVICE, INC. - 1 *OMENS ROOM ) • 1 ::::7 -- ",:=.-:-,.,: - ..-.4...-.... '—+ . • . s 1.1 I • • WI' NE1T4STAT , 'AFF. SET, 'Arip LOK • ;.75F. :I ,‘ • . . EiOST'Cl GAS UNE ON 1 1 t 1 ;!..■ . MUT. HEW. T-STAT 0 ft;*** SET AN D . 1 , 5 V" SW . '• " ; :: 1 ?A/24 : TO N ON . Ft0OF - .„ SEE D . O : THIS IHEET.. " I Y,SKYLiGHT, I . . j . ..-, i . , ON THIS SHEET • EXISTa cos 0' ; • KIST OAS LI NE ON 1, EXIST • : CAS UN • . • • • 7717 , , • • , 24/24 SISM w/ END CAP ON FROM EF ON ROOF 2)03 141NIMUIA: 1 ;1 I ;1/1" INSTALLATION DETAIL 2XR MINIMUM EX JS FAN < SCHEDULE sERV I CE AND MANUFACTURER ; TYPE CF1�1 v01,Ti , NOTES B__;:_ LOCATION A MODEL NO: ii�Lal us . a..h. 3 ,. F . x JP '` r «!d ����� . 2. £F-2 lT'a a'�L' X x " 2 ' �aii' �:! � '' ® � 1.5 1. 2. NOTES il a' 1. POWER„ W RING, DISCONNECT- d MOTOR STARTER EN. ELECTRICAL . CONTRACTOR. 2 . CUTT i NO' AND PATCH I NO.OF ROOF. BY . MO SERVICE .. '. .. 3.`. CONTROL NE* 'EF:TV ITN,LINE.VOLTAGE T -STAY' "USE MONES'MIELL OT 65 1A2028. PROVIDED BYMMS,.I HST ALL ED BY E.C. REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OF TUKWILA BUILDING DIVISION. NOTE: REVISIONS WILL REOUIRE A NEW PLAN SUBMITTAL AND MAY I ": ^IUD': ADDITVV ?!?L PLAN FE-gc EXIi•UST FAN , SCHEDULE P BY ELECTRICAL OCHTRACTOR 'ICE. USE HONEVoeLL #71351A2028 PROVIDED BY WS , INSTALLED BY E. C. REVISIONS • NO CHANGES SHALL BE MADE TO . THE SCOPE OF WORK WITHOUT PRIOR 'APPROVAL OF TUKWILA BUILDING DIVISION. NOTE: REVISIONS WILL. REQUIRE A NEW PLAN SUBMITTAL • AND MAY 100.7 ADDITI1N4L PLAN rn'T11 F77.t MacDonald Miller Company, Inc. 7717 Detroit Ave. S.W. Seattle, Wa 98106-1903 Phone: (206) 703-4400 Fox: (200) 767-4773 Wash Lic No 223-01-MA-CO-01.4-2484 ■■■■•••■•■•••■■•■••••••■■••4•■•■•■•■■■••■•■•■•■ , - rirE . . ESP., Riliall EffPallf : KO' . rz WT/. FM" 340 . NOTES ffluniniarmil iiimitliasiala • • • 4 ° ' '' IlE. 1 1A1 -.4- Ki=11P-Ilai E wail .20 • .F.rizall B..enianil Nano 11311 • 1.5 1 tinimi 11104111 EXIi•UST FAN , SCHEDULE P BY ELECTRICAL OCHTRACTOR 'ICE. USE HONEVoeLL #71351A2028 PROVIDED BY WS , INSTALLED BY E. C. REVISIONS • NO CHANGES SHALL BE MADE TO . THE SCOPE OF WORK WITHOUT PRIOR 'APPROVAL OF TUKWILA BUILDING DIVISION. NOTE: REVISIONS WILL. REQUIRE A NEW PLAN SUBMITTAL • AND MAY 100.7 ADDITI1N4L PLAN rn'T11 F77.t MacDonald Miller Company, Inc. 7717 Detroit Ave. S.W. Seattle, Wa 98106-1903 Phone: (206) 703-4400 Fox: (200) 767-4773 Wash Lic No 223-01-MA-CO-01.4-2484 ■■■■•••■•■•••■■•■••••••■■••4•■•■•■•■■■••■•■•■•■ , - "aC4 .t�': " �` A!g . �,fi ',Ft ,� <t+.Lrv' + o ININO O'SLI AUST FAN INSTALLATION DCTAIL IN1N0 10 SUP DO .. 43r7rY 'G'j.,'n'.4� +3�;..i:�w.� y+.`1Y f. L'k°+: '� 1� % t1.or • XACT BOO AND CURB SIZE " MUST BE CHECKEp TI01A EOUIPUENT SUBMITTALS.. FINAL RESPONSIB1LRY '0R CORRECT BOO AND CURB SIZE NALL BE INSTALLER'S JST TAN INSTALLATION DETAIL CITY OF TUKWILA APPROVED JAN 30 1996 AS U i I_O BUILDING DIV SON FILE COPY I ur.1.' No Plan Ch. sut;:. • • I a c.-;r° and omissiono L pler.3 coos not authorize the violatl cc: °ptcd cods or old copy of ap proved SEPARATE REQUIRED ❑ MEC �ELECTR ❑ PLUMB! ❑ GAS PI C:TV OF T BUILDING D SITE MAP FILE COPY I urc Plan Clic su";: • c,r rs and omissions c.. C.303 not authorial) the violation c, cc 3ptcd code or onINNIMI Isosipt of contractor's copy cf app roved 11111111116clood. By Dato Permit No. M (j7 L5 MAPIRET> SEPARATE PERMIT REQUIRED FOR: Cl MECHANICAL ET 0 PLUMBING GAS PIPING C: o Y OF TUKWILA BUILDING DIVISION lnarw umu Rwo WAY SIT MAP vw.4NY""Yflt•v� .kG.} T'. \tc:.�. /',n,Y.l'�^.'tK}% RECEIVED CITY OF TUKWILA JAN 2 6 1996 PERMIT CENTER REVISIONS: DATE LINDAL CEDAR HOMES BUILDING 'B' 10427 MLK WAY SEATTLE, WA 98178 FLOOR PLAN - HVAC ENGINEER: JCL CHECKED BY: JCL DRAFTER: JCL ISSUE DATE: NOT ISSUED FOR CONSTRtJC1101 • TM-1 LAST REVISED: 1 23--88 DATE PLOTTED: 1 - 25 - 98 CAD REFERENCE: LCPLI.DING DRAWING NUMBER: SC -0337 SHEET NUMBER : co z . ca —J oa f!i 2 0