Permit M96-0014 - BOEING #2-83
rf) q 6 op\ 4- • M I 1■1 It g • "i City of Tukwila �- Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188, Permit No: M96 -0014 Type: 8- MECHAN Category: NRES Address: 8123 EAST MARGINAL WY S Location: Parcel #: 000160 -0020 Contractor License No: BAUGHIC247DZ TENANT BOEING #2 -83 8123 EAST MARGINAL WY 5, SEATTLE, WA 98124 OWNER BOEING PO BOX 3707 - M/S 1F-09, SEATTLE WA 98124 CONTRACTOR BAUGH INDUSTRIAL CONSTRUCTION Phone: 206 726 -3661 900 POPLAR PL S, P.O. BOX 14135, SEATTLE, WA 98114 CONTACT LARRY ALLEN Phone: 206 544 -1644 P.O. BOX 3707 .M /S 19 -35, SEATTLE, WA 98124 kkkk *k *kk * *kkk ** lock*** k********* k** k* k******** * * * *k * * * * * * * * * * * * * * * * * * * * * * ** A **1. * *k'k Signature: Print Name: 44 MECHANICAL PERMIT Status: ISSUED Issued: 05/23/1996 Expires: 11/19/1996 Permit Desert' fori INS TALL- "EXHAUf3T FAN, FLUID .000LERS AND EXTEND PLANT STEAM. UMC Edit 19:94 Valuation Total Permit Fee: ** ** *'*** 4*******' k**** ** * *•k** * * *** * * * ** * *** * *•k ** -D5-ctu (206) 431 -3670 20,000.00 126.56 Permit; Center Authorized Signature Date I hereby certify .that,I have read and examined this permit and know the same tobe true and correct.. All'provisions of law and ordinances governing this work will be complied,with, whether specified herein or not The gran,ting this permit does not presume to give authority'ta violate or cancel, the'provisi.ons of any other state or locel laws 'regulating construction or the performance of work., I am authorized to sign for and obtain this building permit. - Date: LAPi% Title: _, Thk 66 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or:if. the Work is suspended or abandoned for a period of 180 daysHfrom the last inspection. CI 1Y OF TW..WILA i s: 13123 EAST HAPGINAL WY 5 ar i. to : Tenant: BOEING #2 -33i r e. I'vpe: "'B- .144.HAN " ;Parce i # : 000160 -0020 , , , k . M k •k •k •k k k •k k •k .k 4 k •k •k •k 'k •k A• •k •k k •k k 4k •k * k 'k •A k •k k •k •k. 'k •k k •k •k k •k •k •A :4 'k k •k k •A• •k * k. 'k •k •k k A k k 0 •k •.k k •k • k •k k 1 Permit: ..Conditiorti_ .x!:,, I. . No changes .wi 11 be made to the p l ean.. unless approved by the Architect or Engineer and .th :1;uw,i ldih9 OEivi_. 2. Pl.1 permit_.. ins err rye "cor S • , r ed Plan: .hall he available at'the..ioh b ite " "h'rior to th " Stat't any con- s tr action. 1'he a ;,document s are • to be main'raIryed...and avail- able a n t i( f,iei,i ;1 'i n s pe c; t o n a p p r•,p v a i i- : 'i r n t e tt .3. Al 1 con .tr t}r on t,o': be done ` r'i tionlo7 Oe`:with approved plans 'and r,ec u1r of the Bit''( Id in . g od6 (].994 �;� 'Edition . 1`' Uri fi �u ' _. a i ,n a n d�,c , i, •t r�ni iHes:han i'4a l ,r: "ode "0 ”4.., Cd .;t orr;� . and Wa ir State .:ErierilyC'tle,(1994 Edi;ti ` 4'. `Valid tt , of` Permit.e ° ..�� The iui ncc r• of a oe4it r t.ap.pro'.r.a) o,f p lan , f fap,ecit'icati'on , , omput it. ons shall not ,con ed stru to ` be a permit . °±ffo'r• ' }•.Or° an.:.appr• ova 1 of . any v io !at;on of j i " � � ° ' ot` "•tile pro1.i i * i ns. of the bu i 1 d inq code or of any ` ctt {t'' ordin of the. juriJ.dict'o��,_n No permit O esumIng g i u; a authori i' �i a canc. 1 ,the prov i . i ons) of. d r <t ' ' s e' ct1 :�haI be:. va i.i d' .. . ttJ y / ,. e r th r t MAl'4, FACTO CPS', r•1�y:I t,LA7'I.i:► i if t,f' T 1 1 l U 3 S i. ' ;f T.E P;1lirRL ON , i'4 R, Tit E:� ILCrIpt3.- 1i1? FE4..J REVIyEb1 i <''' ,..._ _� t• �...,� , , g ' 0 o P ��rtk�in �}�erri a,•'�iy�al,r �tk�t::ir_1 d' t'hrr,�,�.� � the "�e::tc�t l�:.i; "i C1 � 41 tvi c e par �4,.nrer of ,,Purb,l'i�c' 1 Hee tt'i '' - f'P Iuinbing wi l l ' ° `14 o t y ectt' "by* a ' ' a' s °'1 ;. g .M be ' :. 1�,� i ,,,,,. 'i rt c,'I• ud i'ty"� ^..;,a,1�� °, �:,� piping p i rr � �;�' .. { �t - Q . y �` „4 y k .k a. f a ' •f.: z,, . F � 1 .. -c . a ",1 • E l c xii$4: >1�0 perm its. ha l ,1 be ob at're _ . ,thi'O'4 'r�t..tht- °We. 114010 :3t 10k Cri risionoot Labor and In 1u,.t . e . p nd..,,a.l l a ;actr.`. cal ' wor i l"i the irl pected by that 'aoenc.,ti 't�''4a;(►6304$„1 4. y �/ 3. Read ,y accessible acce to r rf 'niot�n'�:e 1'`ediiip, ent is Permit No M96-0014 Status: ISSUED App 13ed:, 01/31/1996 Issued: 05/•23: 1996. DEPARTMENT DATE IN . . .DATE APPROVED REQUIREMENTS / COMMENTS BUILDING i I - nit a 1-3 l 'cIi , Alkel ( 5122116 - OTED_ CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: • Sprinklers • Detectors • N/A U TIRE FIRE DEPT. LETTER DATED: INSPECTOR: INIT: 0 PLANNING - - -- -- - -- INIT: ZONING: BAR/LAND USE CONDITIONS? • Yes • No SCREENING REQUIRED? Q Yes Q No REFERENCE FILE NOS.: O OTHER : INIT___ i:BUILDING - final review 5] (� UMC EDITION (year): 5z INIT:(�„�,„ 13U ILDIN G t i//4L A _ INIT: A MOUN'1 OWING: )Q CONTACTFD DATE NOTIFIED BY: (init.) 2nd NOTIFICATION BY: (Init.) RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER REVIEW COMPLETED CITY OF TUKWILy . -.: Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PROJECT NAME n oek -it X63 SITE ADDRESS '%1Z 1Y1043410,1 Wj .� SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, o note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. 01/07/93 SITE ADDRESS S I d, 3e- -i- /hart i na SUITE # ( VIIJ G d -g3 VALUE OF CONSTRUCTION - $ p c-- o , o 0 0, 0 °� PRO NAME/TENANT# t A Q 3 0 Repair ASSESSOR ACCOUNT # 0 0o / 6D —a0 0 Other: 0 TYPE OF WORK: ■ New /Addition 0 Modifications DESCRIBE WORK TO BE DONE: ear)-Q- '`,° .',p' ,-�— .s`. TYR ......... RATIf G. 1 °. ; ,... ..:.. T J /S ZE .: :: NUMBER: OF: UNITS : :: .' : BUILDING USE (office, warehouse, etc.) 8 ' 4 NATURE OF BUSINESS: �""�� " /-- WILL THERE BE A CHANGE IN USE? N[ No 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER Aa e _ ,, g (b m , / PHONE / A ZIP 9cY / 5/ / / 4 ADDRESS 9 1, Q � 7 D 2 AO /9 Se tz 4) CONTRACTOR a ri 4 cl 1 74" / ce/ PHONE _5 EXP. DATE / 7`/0 9 cr//5/ / _ y ,� , . y ADDRESS (7, / 3 ,5 ..5 W.A. ST. CONTRACTOR'S LICENSE # A7 � co, p-- 7) CITY OF TUKWILA '! Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER mob - oo 1 U APPLICATION MUST BE FILLED OUT COMPLETELY I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAMETO BE TRU `AND CORRECT,`AND I AM' AUTHORIZED TO' APPLY:: FOR THIS PERMIT DATE BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON SIGNATURE PRINT NAME ADDRESS 0 , 3 7 / 7 'JA' /, 3 to �that MECHAN_:AL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) DESCRIPTION BASIC PERMIT FEE'.: UNIT(S)' FEE PLAN CHECK FEE::::: OTHER:;: :TOTAL . ;AMO.UNT RCP.T::# DATE ;: DATE APPLICATION EXPIRES / —JD -92 PHONE 4/ / 47/5L . CITY/Z11 / " PHONE APPLICATION SUBMITTAL In or der y our application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED I - c 031141W ti SU6MITTAL CHECKLIST MECHANICAL Completed mechanical permit application (one for each structure or tenant) n Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. Perm Par c. Site Ad This Paam A. :k *k *k1. t Corte A(.0/313.830 :0(.10/322.100 4A•h4k *hi(* *A* do • kh: 4 * *4****4Alr**4•k4*4*h **k : 4 A4i*A ** / A* 44A4A*A•1•*It4 AJY ''OF TUKWILA. WA rn (n� ) u TRANSMIT kA� 014• *k .* * *A* % ** * * h h' h * t *hk•k!r*A***h**** **;4 *• ** **•!1. , S •4,1 k I E NSMIT •Number: 3(04186 •(imaunt i 126.56 05/23/96` ['riyltie'nt MGtKod: CHECK Notation: BOEING 'rIUar ACC Init: SLU it No M96• -00.14 rype: B- MECHAN MECHANICAL PERMIT ci No: 000160 -0020 dress: (3123 EAST MARGINAL NY 5 Tcta1 re s: ont 126.66 'fotal AI'L Pmts: Balance: 126.56 .b0 *** A4*• AAItAA**1. 44k*** A4* A** *A *44k*A *4k *44 *44*•le* *4***4* Oesc.r iption PLAN CIII:.CI( - NONRES MECHANICAL -- NCIt}RE6 Amount 26.81 101.25. GENERA 126.; VOID GENERA -126.: CASH 0.1 123 5702A000 16:: mQ.ar'c i a\ "Cf U6i- ( moue L I a 19.5(00 cicl (n•a ;off Pro M61 -g ' Type of inspe ion:t t ^ L M : ,),tcsI . A, Ra 0 s l` �� VY Date called: 2 _ 1 . 7 _ Special instructions: Date wanted, )3 m Requester: A, t ` / 1066, Phone No.: 6%0 0 Y z.4.1∎ :1!..irid.;.! .a kdl;'ykrq•IAre",,V, % ?7ia;1.�� +('f,•,:i Ma(o- pot 4. JON INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: L Inspect I [Receit No.: Date: PERMIT Na 2061...431 -3670 I Corrections required prior to approval. $42.00 REINSPECTIO `' FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Projerds 1J 'w , 1 "j' IN ( t ii ype of Ins , • 4i: I . ` AdcQss; 6. . ivi , 1 Date called:�� � Date wanted: -21 , Special instructions: / k . VA Requester: 1 t Phone No.: Go 5 „ 5y co O COMMENTS: Inspector: Receipt No.: ; E ----4 -1 INSPECTION RECORD '(� Retain a copy with permit I'1'��I 0 ' ci INSPECTION NO. -z,. •- Y3 PERMIT NO. CITY OF TUKWILA B DING DIVISION A �; 6300 Southcenter Blvd., 00, Tukwila, WA 981 1111 :) 431 -36 0 Approved per applicable codes. Li Corrections required prior to approval. t c_// Qe - eshe4k 4/3/- 7o Date: 2 $42.00 - EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Date: 98124 :'n i:lr..4.7 : ?l+ ti!i: ?I7(:;VA4 1 A Jan 31, 1997 LARRY ALLEN P.O. BOX 3707, M/S 19 -35 SEATTLE, WA RE: BOEING ##2 -83 Dear Permit Holder: Sincerely, ` Kelcie J. Peterson Permit Coordinator Department of Community Development PAVVV- FILE City of Tukwila Department of Community Development Steve Lancaster, Director John . an , A o Our records indicate that on Nov 19, 1996 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechanical Permit Number'M96 =0014. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Nov 19, 1996. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 • Viz: .. �.�Z4717Zk� DEPARTMENT OF LABOR ANNDUSTRIES 31-1IS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A STATE OF WASHINGTON / , O %%%%%%%% v` sJ" \OTARY� • • • • c, n rr IUBLIG _. t Lip w ? , RECEIV CITY OF TUK WILA JAN 3 1 1996 PERMIT CENTER F825- 052-000 I*-92) CODE SUMMARY CONSTRUCTION = TYPE V, N OCCUPANCY = B -2, OFFICE AND LIGHT MANUFACTURING SEISMIC ZONE = 3 TOTAL BUILDING AREA = 95,587 SF _ T PROM AREA = 5,106 SF t.IT STRUCTURAL NOTES: '. . DESIGiv AND WORKMANSHIP PER UBC 1994 ROOF LIVE LOAD (SNOW) = 25 pet WIND : 80 mph EXP. C ,., SEISMIC DESIGN : Fp = ZI Cp Wp Z = 0.3 (ZONE 3) -re I = 1.0 LDMG DIVL' u Cp = (2) 0,75 = 1.5 taut Wp = WT OF ELEMENT ENERGY CODE COMPLIENCE: THE PROJECT AREA IS UNCONDITION SPACE. LEGAL DESCRIPTION APN: 000160 -0020, A TRACT OF LAND BETWEEN THE DUWAMISH WATERWAY AS ESTABLISHED BY COMMERCIAL WATERWAY DISTRICT # 1 OF KING COUNTY, WASHINGTON & E. MARGINAL WAY, IN SECTIONS 28, 29, 32 & 33, TOWNSHIP 24 N, RANGE 4 EAST, W.M., DESCRIBED IN: KROLL BOOK PAGE 79, TRACT CONTAINS AN AREA OF /,PPROX 2,897,955 SQ FEET. SITE ADDRESS: 8123 EAST MARGINAL WAY SOUTH I i 1111111 IiI iIIIJI199V'IV mqt,- ooJ 1 4 REVISION Bt APPROVED DATE SAL REVISION By VICINITY PLAN APPROVED DATE AND FACILITY UPGRADE BUILDING 2-83 &SITE PLANT II TUKWILA, WA FACILITIES DEPARTMENT �'1• ESUC, STATE OF WASHINGTON qIR REGISTERED AR ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE F AREVALO WRRELL T. DRAG00 HECKED C. RISKE APPRO W.MOR AMPRgAft IE 1 ( 17 A n L,I/ A n d tt I " SHEET RECEIVED CITY OF TUKWILA JAN 3 1 1996 PERMIT CENTER LAST REVISION GO FACILITY DESIGN SUPPORT U SYMBGI DOFE D JOB NO. COMP NO PL2 -95091 DWG NO. 2 -83 —GO ma6 -ooi� REVISION BY APPROVED DATE REVI Bf APPROVED DATE DEMOLITION PLAN SCALE: 1/8 " =1' -0" FACILITIES DEPARTMENT EXISTING �� UNIT HEATER , ,FA 7 ne,4U / EXISTING UNIT HEATER ,a:ao �i Vi systoNta. ; Yt 1 1 (Tic r ) �Zp V 3 _ ± 3 E do L i = p C, F Cr EXISTING n II ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 5VAPPROVED BY DEPT. DATE RUBBCK A.RUBECK INCR. A.RUBECK CHECKED G.SMITH ED APPROV C.LYN a IP.PF IE \ / EXISTING \ / 2 1/2" CA' SUPPLY UP TO r S' -4" R I , N.- -EXISTNG 2 1 /2 " RETU g 7i —6' I \ 4 EXISTING \\ EXHAUST FAN DATE 0 . , fs4 12.22.95 SUBTITLE TITLE / YARD UTILITIES // \ //, / // EXISTING \ \ /' SUPPLY / FAN / © MECHANICAL MASTER C 1 EXISTING 3" FUNNEL DRAIN TO SANITARY SEWER. REMOVE TO 1' -0" BELOW GRADE AND FILL WITH CONCRETE. EXISTING 3" VENT. REMOVE TO 1' -0" BELOW GRADE AND FILL WITH CONCRETE. AREA OF DEMOLITION (TYP) EXISTING 3" FUNNEL DRAIN TO SANITARY SEWER. REMOVE TO 1' -0" BELOW GRADE AND FILL WITH CONCRETE. 23 EXISTING 3" VENT. REMOVE TO 1' -0" BELOW GRADE AND FILL WITH CONCRETE. DEMOLITION BUILDING 2 -83 LEGEND: CENTER LINE CA COMPRESSED AIR COND CONDENSATE CW DOMESTIC WATER FLR FLOOR STM STEAM TYP TYPICAL GENERAL NOTES: DEMOLITION NOTES: ALL MECHANICAL UTILITIES PENETRATING EAST WALL IN THIS AREA ARE TO BE REMOVED. FIELD VERIFY SIZES. VALVE AND CAP ON EAST SIDE OF WALL AT COLUMN LINE 17 FOR FUTURE USE. MOVE VALVES AT TIME OF NEW CONSTRUCTION TO INSIDE OF MOTOR ROOM. IF ASBESTOS IS FOUND, IT WILL BE REMOVED UNDER SEPARATE CONTRACT. REMOVE EXISTING STEAM UNIT HEATERS. ", REMOVE AND CAP EXISTING 2 1/2" CW BACK TO VALVE AT TOP OF RISER AT APPROX. ELEV. 19' -4" AFF, RISER TO REMAIN FOR MAKE —UP WATER TIE IN BY OTHERS. COL H— J/17 -23 PLANT 2 REMOVE EXISTING 4" CWR. PATCH HOLE IN WALL. REMOVE EXISTING EXHAUST FAN. DO NOT FILL HOLE IN WALL. REMOVE MECHANICAL EQUIPMENT WITHIN THIS BUILDING. REMOVE ALL MECHANICAL UTILITIES INSIDE FENCED YARD AREA. COORDINATE WITH OWNER WHAT ITEMS TO BE TURNED OVER TO OWNER. REMOVE LIQUID RHEOSTAT AND COOLING TOWER. REMOVE LID OF SUMP BENEATH LIQUID RHEOSTAT AND FILL SUMP WITH CONCRETE FLUSH TO GRADE. CONTACT BOEING SHEA PRIOR TO REMOVAL AND DRAINAGE OF LIQUID RHEOSTAT AND TANK. CHECK FOR PRESENCE OF ASBESTOS. REMOVE EXISTING EXHAUST FAN AND OUTSIDE AIR INTAKE LOUVER WITH ENTIRE WEST WALL. REMOVE EXISTING 1" CW LINES 1/2" BELOW FINISHED FLOOR AND FILL WITH CONCRETE. RECE CITV OF TUK WILA � a \ro REMOVAL1 �PACKAGE C �e SHEET PERMIT CENTER LAST REVISION M1R FACILITY DESIGN SUPPORT SYMBOL JOB NO. PLT2/95091 DWG N0. 2- 83 —M1R EMIT 1 or 1 COMP NO. cn cn N v1- C - A \ I CA L -VAC L - G - \ D GENERAL NOTES: GENERAL GENERAL GENERAL SUGGESTED ABBREVIATIONS SUGGESTED ABBREVIATIONS 1. SEE DRAWING M1b FOR ADDITIONAL MECHANICAL LEGENDS AND ABBREVIATIONS. 2. SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL ABBREVIATIONS AND SYMBOLS RELATING TO CONTROL SYSTEMS. 3. DIFFUSER SYMBOLS WITHOUT AIR FLOW DIRECTION ARROWS INDICATE AIR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR LINEAR DIFFUSERS). AIR FLOW ARROWS ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. 4. SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY ARE INCLUDED HERE AS PART OF A STANDARD LEGEND AND MAY BE UTILIZED IN THE FUTURE. 5. DESIGNATES EQUIPMENT APPEARING ON MECHANICAL EQUIPMENT SCHEDULES. T,3T . c\ - v' �' b p X99 p`1 ti 1. ON p�S V` N RE ILA CITY OF TU +1 PERMIT CENTER PACKAGE ee ee 18.95/09:54 95091/591M01AL SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION RECTANGULAR DUCT, FIRST NUMBER INDICA SIZE FOR SIDE SHOWN 1� �� RECTANGULAR DUCT, SQUARE ELBOW WITH TURNING VANES ® THERMOSTAT, REMOTE, CEILING A ANCHOR MV AUTOMATIC AIR VENT AD ACCESS DOOR ADD ANGULAR DOWN DISCHARGE AF AIR FOIL WHEEL AVE ABOVE FINISHED FLOOR AP ACCESS PANEL APPROX APPROXIMATELY ARCH ARCHITECTURAL AUD ANGULAR UP DISCHARGE AVG AVERAGE BI BACKWARD INCLINED WHEEL BDD BACK DRAFT DAMPER BFP BACKFLOW PREVENTER BHD BOTTOM HORIZONTAL DISCHARGE BHP BRAKE HORSE POWER BLDG BUILDING BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE BOS BOTTOM OF STEEL BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR BW BUTTWELD C COMMON Cv FLOW RAEFFICIENT C CAP TEMPERATURE - DEGREES CELSIUS CAPACITY CC COOLING COIL C C BIC RFEE CLOCKWISE MINUTROTATION CENTER LINE COND CONDENSATE CONN CONNECTION COAT CONTINUED /CONTINUATION CPLG COUPLING CPVC CHLORINATED POLYVINYL CHLORIDE CW CLOCKWISE ROTATION DA DIRECT ACTING DB DRY BULB TEMPERATURE ODD DOWN BLAST DISCHARGE DIA 0 DIAMETER - KW KILOWATT KVA KILOVOLT- AMPERE LAT LEAVING AIR TEMPERATURE ('F) LBS, # POUNDS LWT LEAVING WATER TEMPERATURE ('F) MA MIXED AIR MAX MAXIMUM MBH HEAT CAPACITY BTU PER HOUR X 1000 MCC MOTOR CONTROL CENTER MECH MECHANICAL MIN MINIMUM MOV MOTOR V R OPERATED MO AT VALVE MUD, V MOUNTED, R T V NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NORMALLY OPEN / NUMBER FITS NOT TO SCALE NPSH NET POSITIVE SUCTION HEAD OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OF OVERFLOW OS &Y OUTSIDE SCREW AND YOKE OD OUTSIDE DIAMETER OVHD OVERHEAD PBD PARALLEL BLADE DAMPER PD /AP PRESSURE DROP OR DIFFERENTIAL PRESSURE pOS POI TIO OF 0 N CTION INSTITUTE PRESS PRESSURE PRV PRSSURE REGULATING VALVE PS PRESSURE SWITCH PSIG PRESSURE - POUNDS PER SQUARE INCH, GAUGE PSV PRESSURE RELIEF (SAFETY) VALVE PVC POLYVINYL CHLORIDE RA REVERSE ACTING (CONTROLLER) / RETURN AIR RECT RECTANGULAR REF REFERENCE REV REVISE RH RELATIVE HUMIDITY RM ROOM ROT ROTATION RPM REVOLUTIONS PER MINUTE RQD REQUIRED RTN RETURN RV ROOF VENT SA SUPPLY AIR SCFH STANDARD CUBIC FEET /HR SCFM STANDARD CUBIC FEET /MIN SHC SENSIBLE HEAT CAPACITY SHF SENSIBLE HEAT FACTOR SHT SHEET SO SCREENED OPENING SOV SOLENOID OPERATED VALVE SP STATIC PRESSURE SQ SQUARE SS STAINLESS STEEL STL STEEL STRUC STRUCTURAL SW SOCKET WELD SUCT SUCTION TDH TOTAL DYNAMIC HEAD (FEET OF WATER) TEMP TEMPERATURE TH TOTAL HEAD (FEET OF WATER) THC TOTAL HEAT CAPICITY THD TOP HORIZONTAL DISCHARGE THRD TOP OF DUCT TOS TOP OF STEEL TOP TOP OF PIPE TP TOTAL PRESSURE TS TEMPERATURE SWITCH TSP TOTAL STATIC PRESSURE TV TURNING VANE TYP TYPICAL UBD UP BLAST DISCHARGE VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VP VELOCITY PRESSURE T - VERTICAL V VERT VENT TO ATMOSPHERE VTR VENT THROUGH ROOF WB WET BULB TEMPERATURE WCO WALL CLEAN OUT WG WATER GAUGE (INCHES OF WATER) WHA WATER HAMMER ARRESTOR W/ WITH 24/12 I I 24/72 DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST 1 RECTANGULAR DUCT, RADIUS VANED ELBOW ® HUMIDISTAT, WALL b 240 4 ROUND DUCT, NUMBER INDICATES DIAMETER OVAL JO DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER y ,. I I ` EXTRACTION GRID ❑H HUMIDISTAT CEILING I 240 I 24/120 9 144- --�ttii FLEXIBLE DUCT n D DUCT TYPE SMOKE DETECTOR 24/120 I I AIR DUCT, SQ OR RECTANGULA ELBOW F TOWARDS FLEXIBLE DUCT CONNECTION H D DUCT TYPE HEAT DETECTOR arm SUPPLY SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY SIDEWALL SUPPLY AIR DIFFUSER, GRILLE OR REGISTER AND CFM AIR FLOW SR' STATIC PRESSURE REGULATOR NEI I too CFM EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING TOWARDS I S RETURN /EXHAUST AI GRILLE OR REGIST AND AIR FLOW TEMPERATURE ENR, TE SENSOR, DUCT S MOUNSOTED HUMIDITY / ���I I s too CFM EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY SCREENED OPENING AND CFM AIR FLOW d THERMOSTAT, WALL Ma 1 I I F+r 100 CFM I SQUARE TOWARDS RECTANGULAR,�EL ELBOW FACING TYPE, DIFFUSER ORE GRILLE, C OR (4 TYP) OT N NIGHT THERMOSTAT I ,� - am EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY "` , I SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 4) El THERMOSTAT, CEILING J J TRANSITION RECTANGULAR TO RECTANGULAR LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 4) n❑ TEMPERATURE TRANSMITTER � TRANSITION AT TAKE OFF 1r RETURN /EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW 4 s--0, TRANSTION SQUARE OR RECTANGULAR TO ROUND OR OVAL /.....-/v- RETURN /RELIEF GRILLE, CEILING TYPE, NON- DUCTED DIS DEIONIZED WATER SUPPLY DIR DEIONIZED WATER RETURN DN DOWN DS DOWNSPOUT UP UP DUCT OFFSET UP OR DOWN UNIT HEATER, HORIZONTAL VAV BOX LEGEND DWG DRAWING dB DECIBELS EA EA EXHAUST AIR / EACH EAT ENTER AR TEMPERATURE ('F) EFF EFFICIENCY ELL ELBOW ELEC ELECTRICAL ELEV, EL ELEVATION ESP EXTERNAL STATIC PRESSURE EVAP EVAPORATOR EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXIST EXISTING EXT EXTERIOR / EXTERNAL F TEMPERATURE - DEGREES FAHRENHEIT PC FORWARD CURVE WHEEL FD FIRE DAMPER FLIT FLOOR MO FLOOR CLEAN OUT FOB FLAT ON BOTTOM FOF FACE OF FLANGE FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOT FLAT ON TOP FPM FEET PER MINUTE FRP GLASS FIBER REINFORCED PLASTIC FS FLOW SWITCH FEET FV FACE VELOCITY FPM GAL GALLONS GPM GALLONS PER MINUTE GALV GALVANIZED GA GAGE, GAUGE HC HEATING COIL HD HEAD OF WATER HORIZ HORRI ZONTAAL L HP HORSEPOWER HPC HIGH PRESSURE CONDENSATE HR HOUR HVAC HEATING, VENTILATING AND AIR CONDITIONING HPU HEAT PUMP UNIT HTG HEATING ID INSIDE DIAMETER IE INVERT ELEVATION IGV INLET GUIDE VANE INSUL INSULATION IN INCHES I -. IX ' DOWN I 1ST CHARACTER: 2ND CHARACTER: V= VARIABLE AIR VOLUME ' F= FAN POWERED UNIT TERMINAL UNIT C= SHUTOFF UNIT OPPOSED BLADE DAMPER r � LINT HEATER, VERTICAL PROJECTION Min PARALLEL BLADE DAMPER LINED DUCT U t VOLUME DAMPER SOUND ATTENUATOR � k__� H - +I k 3RD CHARACTER: E= ELECTRIC HEAT \ J I El W= HOT WATER HEAT C= NO HEAT ROIL MIK �T� DUCT DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC LINED DUCT WITH ACCESS DOOR AND SMOKE DAMPER MARK NUMBER AD SD LK _--, BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) - -- LINED DUCT WITH AXIAL FLOW FAN BDD AD OR AP ACCESS DOOR (AD) OR ACCESS PANEL (AP) G=I CENTRIFUGAL FAN F� FIRE DAMPER (1 HOUR);; �/ ■ — CENTRIFUGAL FAN, INLET GUIDE VANES EXHAUST FAN SUPPLY AIR FLOW DIRECTION I IFD I FD2 FIRE DAMPER (2 HOUR) I ; FD2 I -4-"-- RETURN, OUTSIDE OR EXHAUST ?I" FLOW DIRECTION M47.1.-70-(): i Ihi FACILITY DESIGN SUPPORT SYM REVISION BY APPROVED DATE SUM REVISION BY APPROVED DATE Mf ' ' - ,,, WASH T .. ,s,' i4 � y : IR. ' iQ ' O c�L�iLp •' SjONA1.�G bnr ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS A PPROVED D RAWN @ Y K UBE I K DATE SUBTITLE HVAC LEGEND REVISION SYMBOL DATE ® ®EZAi� RURUBECK BECK TOLE BUILDING 2 -83 MECHANICAL MASTER COL PLANT 2 H LAST SEE T OF APPROVED BY DEPT. DATE FACILITIES DEPARTMENT CHECKED SMITH ED LYNCH 0, • � W. 12 JOB O. 95091 COMP NO. ' Riff D' NO. 2- 83_M10 PIPING SPECIALTIES SYMBOL DESCRIPTION E3 2 WAY CONTROL VALVE W /PNEUMATIC ACTUATOR X 3 WAY CONTROL VALVE W /PNEUMATIC ACTUATOR A /Q AIR DROP - HOSE, SIMPLEX / DUPLEX e /® AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX T 117 ANGLE GLOBE VALVE, ELEVATION / PLAN 400 AUTOMALOW TROL VALVE (NUMBER TIC IN CON GPM) © - My AUTOMATIC AIR VENT. (WITH DRAIN) BFP BACKFLOW PREVENTER bid BALANCE VALVE WITH METERING PORTS * BALANCE VALVE W/O METERING PORTS Hit /Tit BALL VALVE, OPEN / CLOSED --fill— BUTTERFLY VALVE — I$ — COOLING COIL CHILLED WATER —09— FLOAT VALVE — I:4 FLOWMETER, VENTURI TYPE —IMF -- FLOWMETER ORIFICE - 1x1 - / - 04 - GATE VALVE, OPEN / CLOSE —t GATE VALVE, OUTSIDE SCREW AND YOKE — GATE VALVE, WITH HOSE CONNECTION - DA - / GLOBE VALVE, OPEN / CLOSED — — HEATING COIL 4 / * LIFT CHECK VALVE -MAV • MANUAL AIR VENT (WITH DRAIN) . MOTOR OPERATED VALVE SPRINKLER HEAD, OVER AND UNDER NEEDLE VALVE SPRINKLER HEAD, PENDENT, IN LINE, NEW 0 NITROGEN DROP O NITROGEN OUTLET SPRINKLER HEAD, SIDEWALL, PENDENT, NEW PETCOCK I I — t+1, FE PETE'S PLUG, WITH BALL VALVE —101— PLUG VALVE /STOP COCK : 4, PRESSURE GAUGE WITH VALVE AIi, PRESSURE REGULATING VALVE W /EXT PRESS TAF PIPE TEE, STRAIGHT PRESSURE REGULATING VALVE (SELF CONTAINED) ail PRESSURE RELIEF VALVE / SAFETY VALVE —I I> QUICK OPENING VALVE D QUICK CLOSING VALVE, FUSIBLE LINK SOLENOID OPERATED VALVE Q STEAM TRAP —M SWING CHECK VALVE WITH FLOW / FIRE PROTECTION SYMBOL DESCRIPTION I 2 WAY EARTHQUAKE BRACING X 4 WAY EARTHQUAKE BRACING av ALARM VALVE, WET 0 ASR AUTOMATIC SPRINKLER RISER 101 DRY PIPE VALVE — VP — ELECTRIC BELL FLANGED FITTING - B--II EXISTING SPRINKLER HEADS (TO REMAIN) - o--0 - —0 EXISTING SPRINKLER HEADS (REMOVE) )� ® FIRE HOSE CABINET F�' FIRE DEPARTMENT CONNECTION, WALL TYPE Dcv FIRE DEPARTMENT CONNECTION, YARD TYPE WATER CLOSET, WALL HUNG FIRE DEPARTMENT CONNECTION, RUSH U FDC I-I FH FIRE HYDRANT - 2 HOSE OUTLET 1111111 FH FIRE HYDRANT - 2 HOSE OUTLET AND PUMPER C ONNECTION E FLOW SWITCH O HALON SYSTEM AUTOMATIC DISCHARGE STATION Q HALON SYSTEM, MANUAL DISCHARGE STATION _G5...4 GROOVED COUPLING, GROOVED CAP I] MONITOR SWITCH PIV POST INDICATOR VALVE, YARD t PIPE ELBOW, TURNED DOWN OR AWAY SPRINKLER HEAD, DRY PENDENT . — CO S SPRINKLER HEAD, OVER AND UNDER - SPRINKLER HEAD, PENDENT, IN LINE, NEW • — SPRINKLER HEAD, PENDENT, OFFSET, NEW V SPRINKLER HEAD, SIDEWALL, PENDENT, NEW V SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW —0— SPRINKLER HEAD, UPRIGHT, NEW -- THRUST BLOCK rIV WALL INDICATOR VALVE, PLAN / ELEVATION T WMG WATER MOTOR GONG PIPE TEE, STRAIGHT TAMPER SWITCH PIPE TEE, UP OR TOWARD 101 —I I> REDUCING PIPE FLANGE PIPE TEE, DOWN OR AWAY 1 :1 PIPE FITTINGS SYMBOL DESCRIPTION O BELL & SPIGOT -9---)- SEMI - CIRCULAR WASHFOUNTAIN BLIND FLANGE II —D.— BUSHING 0 EXPANSION JOINT — VP — ROOF DRAIN (OVERFLOW DRAIN - ROOF) FLANGED FITTING - B--II -imm- FLEXIBLE PIPE CONNECTION —0 GROOVED COUPLING HB HOSE BIBB NFHB HOSE BIBB - NON FREEZE TRENCH DRAIN PIPE ANCHOR --X— WATER CLOSET, WALL HUNG PIPE CAP SCREWED OR SOLDER JOINT WATER CLOSET, FLOOR MOUNT - -- V -- PIPE CAP, WELDED OR GROOVED —D VACUUM PIPE CROSS it SR PIPE ELBOW, 9D' SHORT RADIUS --} PIPE ELBOW, 90' LONG \RADIUS PIPE ELBOW, REDUCING ---1- PIPE ELBOW, 45' -- PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW, TURNED DOWN OR AWAY —4 S PIPE GUIDE = PIPE HANGER f r Y PIPING MATERIAL CHANGE, X TO Y PIPE PLUG --14 PIPE REDUCER CONCENTRIC D v PIPE REDUCER ECCENTRIC PIPE SUPPORT —1-- 1 } PIPE TEE, STRAIGHT PIPE TEE, UP OR TOWARD 101 —I I> REDUCING PIPE FLANGE PIPE TEE, DOWN OR AWAY 1 :1 SCREWED FITTING OR AS SPECIFIED I I SEISMIC HANGER / FIXTURES SYMBOL DESCRIPTION O CIRCULAR WASH FOUNTAIN Q SEMI - CIRCULAR WASHFOUNTAIN - ELECTRIC WATER COOLER 0 LAVATORY, ROUND COUNTER MOUNT 0 LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT ORD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) 8 SAFETY EYE WASH FOUNTAIN ( SAFETY SHOWER AND EYE WASH FLOOR DRAIN SERVICE SINK, FLOOR MOUNT I SERVICE SINK, WALL HUNG 1:1 SHOWER STALL AND FIXTURE TRENCH DRAIN URINAL, WALL HUNG CC) WATER CLOSET, WALL HUNG {p WATER CLOSET, FLOOR MOUNT - -- V -- VENT — VAS VACUUM — VPD— VACUUM PUMP DISCHARGE WASTE FITTINGS SYMBOL DESCRIPTION H- 1/4 BEND —RD— CLEAN OUT, EXPOSED — 11 Co FCO CLEAN OUT, FLOOR 0 — RL— CLEAN OUT, WALL —I wco CI FFD FUNNEL FLOOR DRAIN 0 POD FUNNEL DRAIN 0 FD FLOOR DRAIN 0 FS FLOOR SINK I LATERAL ® TRENCH DRAIN OO WR WASTE RECEPTOR, ROOF IlIICO WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT TRAP PRIMER - -- V -- VENT — VAS PIPE IDENTIFICATION SYMBOL DESCRIPTION —PW— PROCESS WATER —RD— ROOF DRAIN — RDS— REFRIGERANT DISCHARGE — RHG— REFRIGERANT HOT GAS — RL— REFRIGERANT LIQUID —RS— REFRIGERANT SUCTION (GAS) — RWL— RAIN WATER LEADER —S— SPRINKLER LINE —SAN-- SANITARY WASTE ABOVE GRADE OR FLOOR -- SAN -- SANITARY WASTE BELOW GRADE OR FLOOR — SPD— SUMP PUMP DISCHARGE — STM — STEAM SUPPLY -- STS- - STORM DRAIN BELOW GRADE - -- TP - -- TRAP PRIMER - -- V -- VENT — VAS VACUUM — VPD— VACUUM PUMP DISCHARGE SYMBOL SLOPE _-EXIST - f"4' /J // --IS S-- — b ,-NEW .POC PUMP GENERAL DESCRIPTION BREAK IN PIPE CROSSING LINES, NO CONNECTION DIRECTION OF FLOW DIRECTION OF SLOPE, DOWN EQUIPMENT MARK NUMBER EXISTING WORK EXISTING TO BE REMOVED HIDDEN OR BELOW GRADE IN -LINE RECIRCULATING PUMP INSULATED PIPE INSULATED PIPE WITH ELECTRIC HEAT TRACING NEW WORK POINT OF CONNECTION REVISION By APPROVED DATE PIPE IDENTIFICATION SYMBOL — A- - AR- -AW- - C- -CD- - CF- - CHWR- - CHWS- -CLD — — CLWR- -CLWS- - CRV- -CRW- - CTFR- - CTFS- - CTWR- - CTWS - CW - DI- - DW- - F- - FN- - FOR- - FOS- - FOV- - G —. — G — HGD- - HPC- - HPR- - HPS — — HPW — — HPWC- - HW- - HWC- - HWS- - IA — — ID- - IW — — IWP- - LN2— — LPC — — LPG — — LPS — — MPC — — MPS — — OFD- - PA — — PCWS- - PCWR- - PC— DESCRIPTION COMPRESSED AIR, PLANT ARGON GAS ACID WASTE CONDENSATE RETURN (GRAVITY) CHEMICAL DRAIN CHEMICAL FEED CHILLED WATER RETURN CHILLED WATER SUPPLY CLEAR WATER DRAIN COOLING WATER RETURN COOLING WATER SUPPLY CORROSION RESISTANT VENT CORROSION RESISTANT WASTE COOLING TOWER FILTER RETURN COOLING TOWER FILTER SUPPLY COOLING TOWER WATER RETURN COOLING TOWER WATER SUPPLY DOMESTIC COLD WATER DEIONIZED WATER DISTILLED WATER FIRE LINE, AHEAD OF ALARM VALVE FIRE HOSE CABINET PIPING FUEL OIL RETURN FUEL OIL SUPPLY FUEL OIL VENT NATURAL GAS GASEOUS NITROGEN REFRIGERANT HOT GAS DISCHARGE CONDENSATE, STEAM (HIGH PRESSURE) CONDENSATE RETURN (HIGH PRESSURE) STEAM SUPPLY (HIGH PRESS, 125 -250 PSIG) HOT PROCESS WATER HOT PROCESS WATER CIRCULATING DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER CIRCULATING — HWR — HEATING WATER RETURN HEATING WATER SUPPLY INSTRUMENT AIR INDIRECT DRAIN INDUSTRIAL WASTE INDUSTRIAL WASTE PUMPED LIQUID NITROGEN CONDENSATE, STEAM (LOW PRESSURE) LIQUID PETROLEUM GAS STEAM SUPPLY (LOW PRESS, 0 -15 PSIG) CONDENSATE, STEAM (MEDIUM PRESSURE) STEAM SUPPLY (MEDIUM PRESS, 15 -125 PSIG) OVERFLOW DRAIN PAINT BOOTH SERVICE AIR PROCESS COOLING WATER SUPPLY PROCESS COOLING WATER RETURN CONDENSATE RETURN (PUMPED) REVISION APPROVED V -C A\ DATE ICAO PIPING LEGE \9 ® ®`7d FACILITIES DEPARTMENT PIPE FITTINGS SYMBOL —iH— �I >— DESCRIPTION SOLVENT CEMENT SPRING HANGER UNION, FLANGED UNION, SCREWED WELDED FRYING SOLDERED FITTING EXPIRES iroe,gy ACCEPTABILITY THIS DESIGN AND /OR SPECIRCATION IS APPROVED APPROVED BY DEPT. DATE PIPING SPECIALTIES SYMBOL U A A 0 U DESCRIPTION TEST PLUG THERMOMETER, LINE MOUNT THERMOMETER, SEPARABLE WELL MOUNT TRAP, FLOAT TRAP SEAL PRIMER VALVE UNCLASSIFIED VALVE VACUUM BREAKER VACUUM DROP (LAB VAC) VACUUM OUTLET (LAB VAC) HARD PIPED VACUUM CLEANING OUTLET VALVE BOX VALVE IN RISER (TYPE SPECIFIED) WATER HAMMER ARRESTOR WYE STRAINER (WITH DRAIN VALVE) UBECi< R RUBECK C HECKED SMITH APPROVED LYNCH CI MR? DATE 1 /10 /q 1, 1 2.22.95 SUBTRLE TRLE MECHANICAL MASTER SYMBOL ROOT OPENING DEPTH OF FILLING FOR PLUG AND SLOT WELDS EFFECTIVE THROAT SIZE OR STRENGTH FOR CERTAIN WELDS TT (E) {o ° L. I I O NYMBO FINISH CO TOUR SYMBOS L { h} (N) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED BASIC WELD SYMBOL OR DETAIL REFERENCE WELDING SPECIFICATIONS, PROCESS OR OTHER REFERENCE DESCRIPTION TAIL (MAY BE OMM REFERENCE IS N ITTED OT USED WHEN GROOVE ANGLE, INCLUDED ANGLE OF COUNTERSINK FOR PLUGWELD LENGTH OF WELD PITCH' (CENTER TO CENTER SPACING) OF WELDS FIELD WELD SYMBOL / I ARROW CONNECTING L —P REFERENCE LINE TO ARROW SIDE OR ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE LINE NUMBER OF SPOT OR PROJECTION WELDS BACK WELD FILLET WELD PLUG OR SLOT WELD SQUARE WELD SPOT OR PROJECTION WELD GENERAL NOTES: COL 1, SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY ARE INCLUDED HERE AS PART OF A STANDARD LEGEND AND MAY BE UTILIZED IN THE FUTURE. may -0014 PIPING LEGEND BUILDING 2 -83 PLANT 2 HECEIVeu CffV OF TUKWILA PERMIT CENTER PACK/AGE «Gee SHEET M1b DWG NO LAST REVISION FN t 1996 P��� D1V1S1ON FACILITY DESIGN SUPPORT SYMBOL JOB O. 95D9 COMP NO 2- 83 -M1b DATE OF PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DECRIPITION CONNECTION (INCHES) TYPE REMARKS SAN VENT HW CW P -1 WATER CLOSET 4 2 — 1 WALL —HUNG FLUSH VALVE NOT USED P -2 URINAL 2 1 1/2 — 3/4 WALL —HUNG FLUSH VALVE NOT USED P -3 LAVATORY 0.250 — 1140 DIRECT N/A NOT USED P -4 MOP SINK 3 2 1/2 1/2 — NOT USED P -5 SHOWER 2 1 1/2 1/2 1/2 — NOT USED P -6 ELECTRIC WATER COOLER 1 1/2 1 1/2 — 1/2 WALL HUNG NOT USED P -7 BAR SINK 1 1/2 1 1/2 1/2 1/2 COUNTER TOP RECESSED NOT USED P -8 SERVICE SINK 3 2 — 1/2 WALL HUNG SEE PLAN P -9 EYE —WASH FOUNTAIN NOT USED P -9A LAV EYE —WASH NOT USED P -9B EYE —WASH 1 1/2 1 1/2 — 1/2 WALL HUNG NOT USED P -10 EYE —WASH AND SAFETY— SHOWER 1 1/4 — — 1 1/4 NOT USED P -11 FREEZE PROOF EYE WASH AND SAFETY— SHOWER NOT USED P -12 WASH FOUNTAIN NOT USED P -12A WASH FOUNTAIN NOT USED P -12B WASH FOUNTAIN NOT USED P -13 LAVATORY 1 1/2 1 1/2 1/2 1/2 WALL HUNG NOT USED FD -1 FLOOR DRAIN VARIES VARIES — — 1/2 "TRAP PRIMER (SAN ONLY) NOT USED FFD -1 FUNNEL FLOOR DRAIN VARIES VARIES — — 1/2 "TRAP PRIMER (SAN ONLY) NOT USED FUD -1 FUNNEL DRAIN NOT USED HUD -1 HUB DRAIN NOT USED EXHAUST FAN (EF) SCHEDULE MARK NUMBER LOCATION AREA SERVED (ROOM NO.) EXHAUST FAN SECTION REMARKS AN FAN SIZE MFG' SIZE NUMBER ARRNGMT. NUMBER CFM TOTAL STATIC PRESS. INCHES WG MAX. OUTLET VELOCITY FPM APPROX. RPM DRIVE SIDE INLET GUIDE VANES BHP MOTOR HP. VOLTS PH HZ EF -1 & 2 SOUTH & NORTH WALL MOTOR ROOM 30 BF3OT — 13,275 0.250 — 1140 DIRECT N/A 5.16 7 1/2 460 3 60 PENN BREEZEWAY TYPE BF, SIZE BF3OT WITH WEATHER SHIELD AND TYPE WS SHUTTER, OR APPROVED STEAM UNIT HEATER (UH) SCHEDULE MARK NUMBER LOCATION TYPE CFM RATED MBH CO EAT 'F LAT .F STEAM PRESS. PSIG STEAM POUNDS PER HOUR TRAP CONDENSATE LBS /HOUR MOTOR REMARKS HP RPM UH -1 MOTOR ROOM HORIZONTAL 716 34.8 45 104 10 50 150 1/25 1550 TRANE MODEL P, SIZE 42 —P —L, OR APPROVED UH -2 MOTOR ROOM VERTICAL 399 30.4 45 100 .0 40.5 120 1/20 1550 TRANE MODEL S, SIZE 31 —S W /LOUVER FIN, OR APPROVED AIR FILTER (AF) SCHEDULE MARK NUMBER UNIT SERVED AIR FLOW CFM/TYPE FILTER REMARKS MEDIA TYPE EFFICIENCY PERCENT MAX FV FMP SIZE EACH NO. REO'D. PRESSURE DROP IN WG CLEAN DIRTY AF -1 OUTSIDE AIR LOUVER 26,550 NON —WOVEN COTTON & SYNTHETIC FIBER 30 -35 500 20x24x2 W H D 18 0.18 0.26 SERVODYNE CORP., SERV —AIRE MARK 80 PLEATED FILTER, OR APPROVED. FILTER HOUSING: AIR SEAL SIDE ACCESS OR APPROVED. REVISION (1) TRANE UNIT HEATER RATINGS ARE AT 2 PSIG STEAM AND 60'F ENTERING AIR. BY REVISION J APPROVED DATE ®OE /NG FACILITIES DEPARTMENT OF T ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE SUBTRLE TYLE MECHANICAL MASTER PACKAGE "C' EQUIPMENT SCHEDULES BUILDING 2 -83 COL H— J/17 -23 PLANT 2 • R1 C RECEIVED GTV OF TU :WILA PERMIT CENTER LAST REASON 10 SHEET M2a JOB NO. 95091 DWG N0. 2- 83 —M2o FACILITY DESIGN SUPPORT pF COMP N0. ( O LEGEND: HEATING SEQUENCE OF OPERATION ® FOR MECHANICAL LEGENDS AND ABBREVIATIONS, SEE SHEETS M:D AND M1b. OUTSIDE AIR INTAKE LOUVER W /MOTOR OPERATED DAMPER. 120 "W x 72"H RUSKIN MODEL ELC6375D OR APPROVED I BOTTOM OF LOUVER ELEV. 24" AFF. SPACE HEATING WILL BE ACCOMPLISHED BY MEANS OF TWO STEAM UNIT HEATERS. 2. BOTH UNIT HEATERS WILL BE CONTROLLED BY ONE COMMON LOCKED THERMOSTAT, I MOUNTED ON AN INSIDE WALL WITHIN THE OCCUPIED ZONE, 5' -0" AFF. I 3. UNIT HEATERS WILL ACTIVATE UPON THE THERMOSTAT SENSING A SPACE TEMPERATURE OF BELOW 45 DEGREES FAHRENHEIT, AND DEACTIVATE ABOVE 45 DEGREES FAHRENHEIT. I I x . — _. —._— --- ._. --, i ._ m - \ ® / .. © 101.- • (rEP) GENERAL NOTES: ■_ - f\ _=- 22 OUTSIDE AIR O E> FOR LOUVER INSTALLATION SEE DETAIL m BOTTOM MOUNTING Q HEIGHT 10' -0" AFF FILTERS A60 A200 ``\ 0 BOTTOM MOUNTING CO 9' `' ' HEIGHT Am' AFF /® -0" I w 20 I E 8 19 II 18 x --CD -- - _ 1T• 1 ti ti IA _I . v O CONSTRUCTION NOTES: SUPPORT UNIT HEATERS WITH: I% UNISTRUT PIERCED CHANNELS P10D0T UNISTRUT BEAM CLAMPS P2867 'z THREADED ROD W /DOUBLE NUTS SEISMICALLY BRACE PER SMACNA WITH CEGELEC x 16 AND DRAWN S AGE A AND B. X X O x E 15 Iit ' IN I IIII 1�KW1�N 2 199 rn C - - 1 - - : - - - .. Mph ❑ I�, 14 o�� S,oN Inn (:), 0011,..1 FLOOR HVAC PLAN N REIVED CIT CE ILA Y OF TUKW O C. E I ^. kNTEF • FIRST PACKAGE `e `e WO SCALE: 1/B " =1' -O° L FACILITY vaiuri 3Urrvm 5 • SYM REVISION BY APPROVED DATE SYM REVISION Bf APPROVED DATE r /� ® ®�,�fi' FACILITIES DEPARTMENT r j e. g • M / � > 4' WASy, T - H� �e - , ' • J .A ; � �� /Qv a'c' ACCEPTABI THIS DESIGN AND /OR SPECIFICATION IS APPROVED WME� DATE SUBrRLE HVAC PLAN -FIRST FLOOR SYMBOL DATE R : , K LAST REVISION SHEEP OF APPROVED BY DEPT. DATE RUBECK TITLE BUILDING 2 MECHANICAL MASTER COL H- J/17 -23 PLANT 2 1 M 10 SM ITH JOB N0. 95091 COMP NO lg 12.22.95 DWG NO. 2-83-1M10 YM VENTILATION SEQUENCE OF OPERATION 1. BUILDING VENTILATION WILL BE ACCOMPLISHED BY MEANS OF MECHANICAL VENTILATION. 2. ALL THREE EXHAUST FANS WILL BE CONTROLLED BY ONE COMMON LOCKED THERMOSTAT, MOUNTED ON AN INSIDE WALL WITHIN THE OCCUPIED ZONE, 5' -O" AFF. 3. WHEN SPACE TEMPERATURES IN THE OCCUPIED ZONE EXCEED 85 DEGREES FAHRENHEIT, THE THREE EXHAUST FANS WILL AUTOMATICALY TURN ON, AND THE OUTSIDE AIR INTAKE DAMPER WILL AUTOMATICALLY OPEN. UPON A DROP IN SPACE TEMPERATURE IN THE OCCUPIED ZONE BELOW 85 DEGREES FAHRENHEIT, THE THREE EXHAUST FANS WILL AUTOMATICALY TURN OFF, AND THE OUTSIDE AIR INTAKE DAMPER WILL AUTOMATICALLY CLOSE. 5. CONTROLS OF EXHAUST FANS WILL PERMIT THE OVERRIDE OF AUTOMATIC FUNCTIONS SO THEY MAY BE OPERATED MANUALLY. REVISION BY H N H H APPROVED DATE REVISION BY APPROVED DATE m v SECOND FLOOR HVAC PLAN SCALE: 1/8"=1-O" AFAZEZAW FACILITIES DEPARTMENT APPROVED BY n. 1 1 H TL II II T _ T ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE ATE / rry 12.22.95 ©© SUBTITLE TITLE MECHANICAL MASTER 17 HVAC PLAN - SECOND FLOOR BUILDING 2 -83 LEGEND: PACKAGE 'Ce' COL H- J/17 -23 PLANT 2 FOR MECHANICAL LEGENDS AND ABBREVIATIONS, SEE SHEETS M1a AND M1b. 22 GENERAL NOTES: CONSTRUCTION NOTES: l% INSTALL IN PLACE OF EXISTING WINDOW. FOR DETAIL SEE 2A10 A200 INSTALL IN PLACE OF EXISTING EXHAUST FAN. FOR DETAIL SEE 2A101A200 COORDINATE LOCATION WITH CEGELEC AND HNTB DRAWINGS PACKAGE A AND B. 15 a p\' 14 Mai? RECEIVED CITV OF TUKWILA PERMIT CENTER FACILITY DESIGN SUPPORT DATE SYMBOL 1.401 REASION SHEET 2M10 JOB NO. 95091 DWG N0. 2- 83 -2M10 OF COMP N0. XPIRES T,e.• 9r/ © H J LEGEND: FOR MECHANICAL LEGEND AND ABBREVIATIONS SEE SHEETS M1a AND M1b. -.(- I I I I I I I Mil r—L r2" (TYP) \\ III 23 O GENERAL NOTES: I D7 © 0 - — ` \ w z w 0 ° m ® 22 1. FOR TYPICAL STEAM UNIT HEATER PIPING CONNECTION, SEE DETAIL X X X X 1M60 M500 — m 1/2" ( TYP) '' 2 1 FOR PIPE HANGER, SEE (nP) © DETAIL 1M60 M500 ® © :2 7 ® `® --/ CONDENSATE PIPING IT HETER COLUMN 1R: NOT 1" PER 40'. � �j El �� g ELEV. APPROX. _ 10 -0" AFF a z LL 2 O O Q STEAM HEADER PIPING TO BE PITCHED DOWN IN DIRECTION OF FLOW; NOT LESS THAN 1" PER 20'. I 1 19 I I I +i! :, T Y . I a Ii MIN EXIST. 1 1/4" STEAM ��-EXIST. 1" CONDENSATE I HH CONSTRUCTION NOTES: I 1� ?, FIELD VERIFY EXISTING PIPE SIZES. J u \ I , REMOVE VALVES INSTALLED I UNDER DEMOLITION PACKAGE. NEW PIPE SIZE TO MATCH EXISTING PIPE SIZE. ® COORDINATE LOCATION WITH CEGELEC AND HNTB DRAWINGS PACKAGE A AND B. E4 INSTALL PIPE TIGHT TO PEDESTAL IN VICINITY OF STAIRS TO AVOID LOW HEAD CLEARANCE. FIELD VERIFY. b 15 — _ . 1 1I I I ■ \bKw E p " �t P - ® v,,,-( 12 X996 a U — nn CI 0 ... Ob 1 FIRST FLOOR STEAM PLAN 1 0-1 N RECEIVED CITY OF TUKWILA PERMITCENTEA P A K A E e ` « SCALE: 1/8 =1' -O" ti.x.s1 rsi FACILITY DESIGN SUPPORT S SYM REVISION 6T APPROVED DATE SYM REVISION Bt APPROVED DATE �s ®®EZAV FACILITIES DEPARTMENT V L. SM I - _ v rA H', � T � °- yF 1�.,_ " I# > eo , 0,4,70,713'A, 4""'-g� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN gY RUBEGK DATE SUBfTLE STEAM PIPING PLAN LAST REVISION SHEET SYMBOL DATE OF _ APPROVED BY DEPT. DATE RUBECK TITLE BUILDING 2 -83 MECHANICAL MASTER COL H- J/17 -23 PLANT 2 1 M 6 0 C D SMITH 1 / 96 JOB NU. 95091 LUMP NO 'FOY 1 2.22.95 DWG NG. 2-83.4460 XPIRES T,e.• 9r/ REVISION BY N rrgb-DDI APPROVED DATE REVISION BY APPROVED DATE 4 FA iSKEZA FACILITIES DEPARTMENT 3/4" A UP. VALVE AND CAP 12" ABOVE MEZZANINE FLOOR FOR TIE -IN TO MOTOR DISC BRAKES. — m ED ED 1/2" ® /1/2"A (TYP) DRIP LEG E> 1/2" A DOWN AND UP ©© D] m 1/2" A DOWN AND UP /-� �� 1 DRIP LEG E> ■ -iii EXIST. 1" A g ELEV. 14" AFF� IN MOTOR ROOM FIRST FLOOR COMPRESSED AIR PLAN SCALE: 1 /8" =1' -O" DoNAL G 1" A APPROVED BY 1 /2 "A DN. => 1" A 0 ELEV. APPROX. 10 -0" AFF * POC Q ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE m WEEK Y. X DATE SUBTITLE TITLE LEGEND: FOR MECHANICAL LEGENDS AND ABBREVIATIONS, SEE SHEETS M1 AND M1 b. 22 GENERAL NOTES: • FOR LOW POINT DRAIN, SEE DRIP LEG DETAIL MECHANICAL MASTER 21 20 19 18 15 14 COMPRESSED AIR PLAN BUILDING 2 -83 �Z FOR WALL MOUNTED DUPLEX AIR OUTLET DETAIL, SEE 1M110 M500 3> FOR FLOOR MOUNTED DUPLEX AIR OUTLET DETAIL, SEE 1M110 M500 PACKAGE "Cee COL H- J/17 -23 PLANT 2 1M110 M500 ® FOR PIPE HANGER, SEE DETAIL 1M60 M500 CONSTRUCTION NOTES: �i FIELD VERIFY EXISTING PIPE SIZE. 2�' REMOVE VALVES INSTALLED UNDER DEMOLITION PACKAGE. NEW PIPE SIZE TO MATCH EXISTING PIPE SIZE. COORDINATE LOCATION WITH CEGELEC AND HNTB 1 r DRAWINGS PACKAGE A AND B. V 2 PAINT TOP OF GRATING 1' -0" ON ALL SIDES OF PIPE PENETRATION THRU MEZZANINE WITH SAFETY YELLOW PAINT. INSTALL PIPE TIGHT TO PEDESTAL IN VICINITY OF STAIRS TO AVOID LOW HEAD CLEARANCE. FIELD VERIFY. FlECEIVED CITY OF TUKWILA I /TA PERMIT CENTER LAST REVISION SHEET 1M 110 JOB N0. 95091 DWG N0. FACILITY DESIGN SUPPORT SYMBOL DATE 2-83-0,411 Of COMP N0. AUT 7 iR VENT OMATIC LEGEND: �, g OOOSYll6S/TW16OS6 eo /s6'6L ZL /'lSN TO EXISTING CONDENSATE AT COLUMN LINE 17. CONDENSATE 3/4" TO ATMOSPHERE PRESSURE REDUCING FOR MECHANICAL LEGENDS AND ABBREVIATIONS, SEE SHEETS MIa AND M1 b. 1/4" QUICK DISCONNECT VALVE (PRY), SPIRAX SARCO ; '; F '' , MODEL BRV2, 3/4 NPT ; \ ©� (2TYP) i � 3 4 T / n SDI `� Snul 1/2" � 1j2" 7 am d d ^ ^,; rY i4d, ^ ^• it;? r, ; 2;15 ?s.� .24. :... .n..� P -1000 UiIISINUT =__ _ �- 1/2x3/8" =_ 4 "LG W /(2) 1/4x2" HEX BUSHING p � TOGGLE BOLTS : p SOCKET, PARKER B22E 1/4" QUICK DISCONNECT BODY x 3/8 "MPT ILL STEAM .,c)/ (125 PSI) TO EXISTING STEAM AT COLUMN LINE 17. I I STEAM (10 PSI) 3/4 ° � 1 - • T .. , =_ I II � r -- CZ I ° 4;1 II I i rr , _° ��I lam 1/2" STREET ELBOW TYP �� Y 1/2 "TEE 1/2 1/2 GENERAL NOTES: UNIT HEATER 1 7' BALL VALVE EL 5'4' AFF .w� 1/2" VALVE .INT. I __ °� _ �o r, PIPE SLEEVE STEAM TRAP, 1/2 "TEE 1 /2'STREET ELBOW '-' MEZZANINE FLOOR �.- n u FLOAT & THERMOSTATIC, SPIRAX SARCO 3 4" / I,-111-"\- _ 1/2x3/8 HEX BUSHING . IA, 1 I mo . � ,107-: � 1 If +� �' (TYP) 42 AFF. /� C� Of C� __ -- ii STEAM UNIT ��I --+I I �F— '6 '- HEATER COIL PIPING _ -DRIP LEG e SYMBOL n WALL ■nN WALL (REF) 1/4" QUICK DISCONNECT .�! II1 SOCKET, PARKER B22E 1/4° QUICK DISCONNECT 5 BODY x 3/B "MPT (TYP 2) �p e SYMBOL �^' MOUNTED DUPLEX AIR OUTLET (2 FLOOR MOUNTED ` ... DUPLEX AIR OUTLET SCALE: NONE 1M6011,21500 NO SCALE iM110 M500 NO SCALE 1M11&1500 SECOND FLOOR FRAMING ROOF b 1o1 B -LINE FIG. B3363 • P. 16 - B -LINE FIG. B3036L P. 15 FOR WALL PENETRATION DETAIL SEE ARCHITECTURAL DRAWING CONSTRUCTION NOTES: 1/2" AIR MOTOR ROOM — Ii B -LINE FIG. 83170 o . -_- III 1/2 " BALL VALVE P. 42 2" V PRIOR TO CORE DRILLING ROOF, VERIFY LOCATION AVOID INTERFERENCE. SEE CIVIL DRAWINGS FOR INVERT ELEVATION OF 3" SAN LINE. HONEYWELL 3/4" TWO POSITION CONTROL OUTSIDE WALL VALVE MODEL #V5045A WITH MOTORIZED ACTUATOR MODEL #V2045A1038 AND AUXILLARY SWITCH ASSEMBLEY MODEL #1141918. PROVIDE WITH 120 TO 24 VOLT TRANSFORMER AND 24/120 VOLT FAN RELAY FOR EACH UNIT HEATER. FANS ARE TO ENERGIZE AND CONTROL G VALVES ARE TO OPEN WHEN THE THERMOSTAT CALLS FOR HEATING. PROVIDE ALL EQUIPMENT AND APPURTENANCES FOR A p ii II, urn __ , 1/2" THREADED HOSE CONNECTION NOTES: 1. SIZE HANGER AND CLAMP TO ADEQUATELY SUPPORT LOAD P -8 -" - FLOOR (REFER TO B -LINE HANGER CATALOG). FINISHED 3" SAN 2. FOR COPPER TUBING USE COPPER PLATED OR PAINTED FLOOR B3170CT, FELT LINED B3170F, OR PLASTIC COATED HANGERS. 111TTLLL 3. ONLY B3036L IS UL & FM APPROVED. COMPLETE 3" SAN FOR CONTINUATION � AND OPERATING SYSTEM. SEE SHEET 0290 HONEYWELL THERMOSTAT MODEL # ( ( t% T87F1826 WITH MODEL #TG503A1000 METAL LOCKING THERMOSTAT GAURD . f.ITROF TUKWILA ..„,,3,,. & � HERMIT s :ENTER fn DRIP LEG ' 4. USE B3363 RETAINING STRAP WITH B3036L. 5. FOR PIPE SIZES 2" AND UNDER, USE B317ONF. 6. GRINNELL MAY BE USED IN PLACE OF B -LINE. P IPE HANGER ( � � SERVICE SINK (P -8) WASTE ( - NO SCALE 1M110 FOR MOISTURE REMOVAL FROM AIR SYSTEM M5C0 SCALE: NONE 1M60,1M110,1M111 M500 SCALE: NONE 1Mii M500 tt tt P A A G C !� e FACILITY DESIGN SUPPORT SYM REVISION BY APPROVED DATE SYM I REVISION BY APPROVED DATE FA r' ® ®� ®/� FACILITIES DEPARTMENT f ,. X L. S y . M J � , ... SH�4. 0' f ''' ', _ p ' 1. I 18360 o EctEDOw0 R'ONALVH ACCEPTABILITY SPECIFICATION IS APPROVED DRAWN DATE SUBTITLE IT LE SECTIONS AND DETAILS TITLE BUILDING 2 -83 MECHANICAL MASTER COL H- J/17 -23 PLANT 2 LAST REASON SYMBOL DATE [y GE � SHEET M500 OF BY DEPT DATE RCK RACK � .,, �� EU LYNCH C. Q� 12.22.95 JOB N0 95091 COMP NO. P R WE DWG ND. 2- 83 -M500 I EXPIRES ",OFAL LEGEND: G (SEE SHT. E509 FOR LIGHT O w FIXTURE SCHEDULE) ®--I INCANDESCENT LIGHTING FIXTURE, ONE LAMP, 200 WIF, WALL MOUNTED HOLOPHANE, X420. .' II II 3/4 III U it 1) ) r _� _,_ •I __! ., I EXIT'DS LIGHTING DOTWN LIG FIXTURE, 2 HEMCO NX -11 -DL (GREEN). AK 1 I II II II II II ( " 2 TYP,) X INCANDESCENT LIGHTING FIXTURE ON NIGHT LIGHT CIRCUIT. '' © 120/277V EMERGENCY LIGHT � (5 TYppP.) ' -� ® ON EMERGENCY EXIT LIGHT (UNSWITCHED) 3 �+ maim U �I„ �I II R2 114/ (34 TYP.) ® 4 -FT. FLUORESCENT LIGHT FIXTURE 2-LAMP, 1l® 2 -LAMP, 4 -FT. FLUORESCENT LIGHT FIXTURE, WITH BATTERY PACK ( UNSWITCHED) Imo» 2 -LAMP, BFT. FLUORESCENT LIGHT FIXTURE R1 II R2 1 01 • / /// ri II R 4b II \ // III /` R1 � �Rt I : u IJIA� J! III C. I R3 [] R2 ® $ 1 -GANG 1 -POLE TOGGLE SWITCH 3$Lv 3 -GANG LOW VOLTAGE SWITCH X X X X THIN BUILT7I WREVOBLOTXAGE LT GE POWEP, :::1 I R 2 4b //� i / // II R /// II R �// � R1 II II R3 II R2 �R3 � R1 U II R1 II �� I1 R 4b II : a s PN L R Y, SW G IT E CH R sPEAgwEWRI : 2 1 . i II 1 � 1/2"C, (3)3/C# 8 mil ' �, II 12 H131 /!f/ le [11 V' ft] R3 GENERAL NOTES: "C, 2H "C, 4 #12+ 12G c #10+ 12 PNL 9 20 R } II i3? II a� . I�3/4 „ , 4b II R1 E3 �I r 20 1. RACEWAYS: 1/2" EMT, UNLESS OTHERWISE NOTED. 2. CONDUCT 12AWG, STRANDED COPPER, INSULATION 4b(R2), 6c R3 TYPE THHN /THWN, UNLESS OTHERWISE NOTED. 1 /2 °C, (3)3/C C #1 8 �I II II !! R3 pp 1 9 3. COLOR CODE OF CONDUCTORS: 208Y/12OV 480Y/277V J _ :, _ n . G� `_+ � 1 � . I 4b 8 A 0 (LEFT BUS IN PNL) BLACK BROWN B 4 CENTER BUS IN PNL) RED ORANGE RIGHT BUS IN PNL) BLUE NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN ISOLATED GROUND GREEN WITH YELLOW TRACER [ [ I 1[i]d / /� _! 'Mill II . u.:. 1 8 4. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC. WITH PANEL AND CIRCUIT IDENTIFICATION. 5. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. x 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES. 4b v �l! f i __ __ I H� 1 I \ \ CONSTRUCTION NOTES: 1� PROVIDE WIRES AND CONDUIT (THROUGHOUT). H 10- PROVIDE SWITCH AS SHOWN. EXISTING MONORA I FOR 9c DRAW PROVIDE LIGHT FIXTURE AS SHOWN. PROVIDE POWER SWITCH PACK AS SHOWN. 1 J , H 3/4 "C _ II 1D _ �, • e. \ 1 'C, # — 1"C,-#12 x/ 7 — =' =A S�= VIII : 3 — 0 - 0 i I I II H i H ' O , - 12 18 3/4'C,-*12 8 3,6 "C, -912 - _ 8 . "C, - 9 1 2 II 7 1 "C,-912 , II I X11_ 7 1 ! io Aim 0 II , B El AN 1111 C 15 II _ „ ,E„ x .,.�. �, I I R, \\N. - WTR /7,8, H �n 0 n 111 X x ii 10 10 20 J 20 - 1 14 f 5 4 s II I 2 s 18 �18 - —J I... - ' II �, " 30 II . )q "- -91a.� s – 4w__ Hi8 E12 lL� ` i 1u - 3/1 „ C N70 ��, _ ,�� ', _e�� T _ _ _ I --e-1 r _ – – 5 ,E s , } KEY PLAN b ( ( 4 FIRST FLOOR PLAN _ RE�EI�E SCALE: NONE Q 0 n / i F R n R CITY OF IUKWILA p 0. n .SCALE: 1/8 0 1 .. ... ... �ERMI CEIJTEP FACILITY Z DESIGN SUPPORT g SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ®E ® EMI FACILITIES DEPARTMEN v> C ' N' L ° � 0 / t ;,`o;r;c:: .y ACCEPTABILITY THIS DESIGN AND /OR . r SPECECATION M APPROVED Dgn(I BY AKKO Y. DATE 10.22.90 SUBTRLE LIGHTING FIRST FLOOR PLAN IAST REVISION SYMBOL DATE 01.08.96 - A CAD LOADED FROM 102-083-2001 ADDITIONAL LIGHT DSO #D2040272 AY SSH GLB 10.25.90 01:10.93 D UPDATE BM MN DS J '' +I l o� I> > CHECKED C ROTE 12.10.91 'LE BUILDING 2-83 SNEET 1 E 10 OF BY DEPT. DATE B EMERGENCY LIGHTS J # 730046 -00 PATRICK SSH s 03.31.,:3 CHECK C PROVIDE EMER. LTG. J #730257 - KNOX SSH 11.24.93 APPROVED JOB N0. PL2 -95091 COMP NO - AS BUILT DAC SSH 05.18.94 APPROVED ELECTRICAL MASTER COL A- J/13 -23 PLANT 2 DK N0. 2- 83 -1E10 txr,, J R6) (R4), � I it R • R5 R6 V// O •3b PNL 2H19 lib, ' Iifr ', _ 11 � r. f b #12G II R6 ' , • R4 3/C #18 I ra M1 ,p � - _ � K �/ F oh (\ [ ;b TT 1111 II IlII CONSTRUCTION NOTES: PROVIDE WIRES AND CONDUIT (THROUGHOUT). 2 PROVIDE SWITCH AS SHOWN. >' PROVIDE LIGHT FIXTURE AS SHOWN. PROVIDE POWER SWITCH PACK AS SHOWN. 5> PROVIDE PHOTOCELL CONTROLLER WITH POWER SUPPLY. PROVIDE OUTDOOR TYPE PHOTOCELL SENSOR. B REVISION CAD LOADED FROM 102 - 083 -2001 ADDITIONAL LIGHT DSO #D2040272 EMERGENCY LIGHTS J #730046 -00 PROVIDE EMER. LTG. J #730257 -DO AS BUILT OA° -oo►�I BY APPROVED DATE AY 10.25.90 SSH GLB 01.10.93 PATRICK SSH 03.31.93 KNOX SSH 11.24.93 DAC SSH 05.18.94 SYM UPDATE BTWT REVISION SECOND FLOOR PLAN SCALE: 1/8"=1 N ® ®E /�/ FACILITIES DEPARTMENT 3/4 "C, 3#10+ PNL 2H19/25a 27b(R5), 29c( 1/2 "C, (3) 1 /2"C, 2 #1 PNL 2H19/ ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 'APPROVED BY DEPT. DATE APPROVED APPROVED CHECrzeD ENGR. G. BOYE CHECKED DATE 10.22.90 12.10.91 SUBTITLE TOLE ELECTRICAL MASTER 2 ® POWER SWITCH PACK WITH BUILT -IN LOW VOLTAGE POWER SUPPLY, G.E. RSENPWR IN 4" x4" SQUARE BOX 17 PA CKAGE "C" NERMR CENTER LIGHTING SECOND FLOOR PLAN BUILDING 2 -83 LEGEND: G FIXTURE IDENTIFICATION (SEE SHT. E509 FOR LIGHT 59 FIXTURE SCHEDULE) ''ES' 277V EMERGENCY LIGHT (UNSWITCHED) 0-1 EMERGENCY EXIT LIGHT (UNSWITCHED) ® 2- LAMP, 4 -FT. FLUORESCENT LIGHT FIXTURE ® 2 -LAMP, 4 -FT. FLUORESCENT LIGHT FIXTURE, WITH BATTERY PACK (UNSWITCHED) 0 CEILING MOUNTED METAL HALIDE LIGHT FIXTURE I (� WALL MOUNTED METAL HALIDE LIGHT FIXTURE $ 1 -GANG 1 -POLE TOGGLE SWITCH 3$LV 3 -GANG LOW VOLTAGE SWITCH E PHOTOCELL CONTROLLER G.E. CAT. #RPCON WITH ENCLOSURE G.E. CAT. #RBS2, AND POWER SUPPLY G.E. RPWR277 ® PHOTOCELL SENSOR G.E. CAT. # RPSEN -OUT MOUNTED TO A WEATHERTIGHT JUNCTION BOX. GENERAL NOTES: 1. RACEWAYS: 1/2" EMT, UNLESS OTHERWISE NOTED. 2. CONDUCTORS: #12AWG, STRANDED COPPER, INSULATION TYPE THHN /THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE OF CONDUCTORS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B 0 CENTER BUS IN PNL) RED ORANGE C 0 RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GREEN WITH YELLOW TRACER 4. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC. WITH PANEL AND CIRCUIT IDENTIFICATION. 5. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES. COL A- J/13 -23 PLANT 2 N RECEIVED SCALE: NONE KEY PLAN C) CITY OF TUKWILA SHEET 2E10 JOB N0. DWG N0. LAST REVISION PL2 -95091 2- 83 -2E10 Ot FACILITY 5 ' DESIGN SUPPORT g SYMBOL DATE r) 01.08.96 DE COMP N0. T 3b i/ r .. 1 M MN �j 1 I R4 • L_ l R5 1 3' : � _ m( 6 TYP.) L_ ( 1 _w_i i : R6 (18 TYP.) :AII m (•3b 400 (5 flp ) ■ ' R r ' ' R )11>, '■ #12G F FI " " 1111 II IlII CONSTRUCTION NOTES: PROVIDE WIRES AND CONDUIT (THROUGHOUT). 2 PROVIDE SWITCH AS SHOWN. >' PROVIDE LIGHT FIXTURE AS SHOWN. PROVIDE POWER SWITCH PACK AS SHOWN. 5> PROVIDE PHOTOCELL CONTROLLER WITH POWER SUPPLY. PROVIDE OUTDOOR TYPE PHOTOCELL SENSOR. B REVISION CAD LOADED FROM 102 - 083 -2001 ADDITIONAL LIGHT DSO #D2040272 EMERGENCY LIGHTS J #730046 -00 PROVIDE EMER. LTG. J #730257 -DO AS BUILT OA° -oo►�I BY APPROVED DATE AY 10.25.90 SSH GLB 01.10.93 PATRICK SSH 03.31.93 KNOX SSH 11.24.93 DAC SSH 05.18.94 SYM UPDATE BTWT REVISION SECOND FLOOR PLAN SCALE: 1/8"=1 N ® ®E /�/ FACILITIES DEPARTMENT 3/4 "C, 3#10+ PNL 2H19/25a 27b(R5), 29c( 1/2 "C, (3) 1 /2"C, 2 #1 PNL 2H19/ ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 'APPROVED BY DEPT. DATE APPROVED APPROVED CHECrzeD ENGR. G. BOYE CHECKED DATE 10.22.90 12.10.91 SUBTITLE TOLE ELECTRICAL MASTER 2 ® POWER SWITCH PACK WITH BUILT -IN LOW VOLTAGE POWER SUPPLY, G.E. RSENPWR IN 4" x4" SQUARE BOX 17 PA CKAGE "C" NERMR CENTER LIGHTING SECOND FLOOR PLAN BUILDING 2 -83 LEGEND: G FIXTURE IDENTIFICATION (SEE SHT. E509 FOR LIGHT 59 FIXTURE SCHEDULE) ''ES' 277V EMERGENCY LIGHT (UNSWITCHED) 0-1 EMERGENCY EXIT LIGHT (UNSWITCHED) ® 2- LAMP, 4 -FT. FLUORESCENT LIGHT FIXTURE ® 2 -LAMP, 4 -FT. FLUORESCENT LIGHT FIXTURE, WITH BATTERY PACK (UNSWITCHED) 0 CEILING MOUNTED METAL HALIDE LIGHT FIXTURE I (� WALL MOUNTED METAL HALIDE LIGHT FIXTURE $ 1 -GANG 1 -POLE TOGGLE SWITCH 3$LV 3 -GANG LOW VOLTAGE SWITCH E PHOTOCELL CONTROLLER G.E. CAT. #RPCON WITH ENCLOSURE G.E. CAT. #RBS2, AND POWER SUPPLY G.E. RPWR277 ® PHOTOCELL SENSOR G.E. CAT. # RPSEN -OUT MOUNTED TO A WEATHERTIGHT JUNCTION BOX. GENERAL NOTES: 1. RACEWAYS: 1/2" EMT, UNLESS OTHERWISE NOTED. 2. CONDUCTORS: #12AWG, STRANDED COPPER, INSULATION TYPE THHN /THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE OF CONDUCTORS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B 0 CENTER BUS IN PNL) RED ORANGE C 0 RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GREEN WITH YELLOW TRACER 4. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC. WITH PANEL AND CIRCUIT IDENTIFICATION. 5. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES. COL A- J/13 -23 PLANT 2 N RECEIVED SCALE: NONE KEY PLAN C) CITY OF TUKWILA SHEET 2E10 JOB N0. DWG N0. LAST REVISION PL2 -95091 2- 83 -2E10 Ot FACILITY 5 ' DESIGN SUPPORT g SYMBOL DATE r) 01.08.96 DE COMP N0.