Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M96-0057 - BEST WESTERN
nniqb,00s7 bET wesTERA City of Tukwila .s: Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 •. Tukwila, Washington 98188 Permit No: M96 -0057 Type: B- MECHAN Category: RES Address: 15901 WEST VALLEY HY Location: Parcel #: 000580 -0030 Contractor License No: NORTHWH103R2 Signature: MECHANICAL PERMIT (206) 431-3670 Status: ISSUED Issued: 04/17/1996 Expires: 10/14/1996 TENANT BEST WESTERN 15901 WEST VALLEY HY, TUKWILA, WA 98188 OWNER NENDELS Phone: (206)533 -4200 LIU SHUH -WEN, 616 W HERON, ABERDEEN WA 98520 CONTRACTOR NORTHWEST WATER HEATER, INC. Phone: 206 282 -4700 2800 THORNDYKE AVENUE WEST, SEATTLE, WA 98199 CONTACT MONTY PEIL Phone: 206 282 -4700 2800 THORNDYKE AVE WEST, SEATTLE, WA 98199 * *•k * * * ****k*** k********* k*** k**** kk*• k** kk* k*k** • k** *i** *k * * * * * * * * * ** Permit Description: REPLACE TWO EXISTING BOILERS AND INSTALL STORAGE TANK. UMC Edition: 1994 Valuation: 7,270.00 Total Permit Fee: 60.38 * * * ** k** ** k *•k * *•k * * * *•k * * * * * * * ** k k* k * * * * ** k k k k k k* k k** k * * * * ** * * * ** * * ** Permit Center Authorized Signature Date I hereby. certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinandes governing this..work will be complied with, whether spedified herein or not. The gran,ting:;of this permit does not'presumeto give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building p I� - ,, n 5h4 Date: Lk 17 d% Print Name:__ 6 1:1i) 0E015040 Title: rA0VVi mosTA. LEZ_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the-work is suspended or abandoned for a period of 180 days from the last inspection. • 1:.1T;E': OF TW :FLA 'r` ?' e:o s: 1 5901 .WE .1 ''VALLC` tiY "ca 01 t e'r 'l't n ca li f BEST WE TER N Type '13- 4MECHAN par del #: .00058O- 00310_ f i .h •k '!i. '4 '4 k •4. '4 •4 '4 4 1 ' k :k.'fi '4 : t '4 '4 'k *44444444 'k '4 '4 '4 '4 'h •4 ' 4 '4 4 '4 4 '4 '4 '4 4444444444.44444444 4 4 k 4 4 4 '4 Per rnit:, Cond.itian_.c 1 s Wo Changes will be n1? : to the plans. unlesS app =•oVed by the ,• `hr chi.tect or' Engiriee and 11e lulftt "�.La Bui lcting Division.' 2, A11. ,pe; nilt . 1nspec:.t,i.pn7�P4en,e,pki "� ::;d 4pprv' o.ed pIar�.= :hall be' av i lab le .;at. the ,1,C► "r .i t'e" prior• to t'h . t'..f con- struct 'con- struct lon. 1 h , e-tio'cument `' a :re t o: bt . ma tnt aid a'- i 1 abler unt:1 1 1 Ina; '1'� ;p'e.cI1on" is. 0rAnteci �f ( } {. 3. All. Con k:r urA t'i -c+n t;'o Y �f i .� I he z lone O,i'n'"Actlnt`or•mcance��, f � w1 th 440,,pved pIan S • Lind. `et)trire,.niettil.4, f the UhA orm But Id n,},:g,:i. ;1 ode� Edition 1,a"' apte.p dt¢i' Uni.faitca'He {n''i'ct l: t.o (1 4 Edi'tion). and W�as� ti,rt!z► n S.tt #te er gy�' Code ,.1994 Edir't ior�'r,r. i r;> ' 4 Val i"tii ° t;�,!`ot' P .s lhe is: fuan ; „ °e of a peen )#.?. o`� plan qt t "�,,:: Rec. ificL�t.riions }anti Cxlrrpu,e' ion's "s'hca11 ot....;bbe GCfr1 y r �� t. ;� ;; , .. ,:, -. r , t,1 Pe a p, i r�mi C: '; '6 , .�r an.,.pf app•r•0va 1 of y e'rb a i;l'lAt: i 0 of an of . p't•ov1 , ions of�tthe' building code or,tttx..attti' \'' ott.epY qt d ``ryance. of fhe. iuri,, d1c.tlt.m. No permit Oes.um,ffnQ h i,Fe :� authot►` qt to 0'0 w l a t'e "''or'' car:t.tl f t: he LtP'ou i . ions• of th°1 s cc i:e shall � be, v 1tl"+Ct�`. -.tf if t r. MAN F AC1'UREPS Ju 1 ALLAI'I N INSI1t��IJC 1 JO S. f E')U11 ED ON ' 11 1~ P; 1 HA Bo L L'i��UG-- 1K +,, l F't i J 7, P fu b i r rr , rit.. ,t�f lralr1 t)t `oht: a tg,edi.t.hr 'ii.tr►� t: ec%t t C , I t\ UeI).., : rirO A . of-'',Publi,cHea1th. 1- lumping wi 1l ; < •r. : r J it L� r CtN "`t1V4 haf >�ILL° ill 11 l`CIt� "i't1 a�I�.C" a pTItinl�i b � ;wt, { ,<; 1 i ( 6-.a :7 C' a ti :,;.A y '..,,, , ''2, .' � . f , .� ' ,R? � p �' f ,� ,:�, ,. { . ., % .:. '' "� ,+' . � 111444 3,' Ele t tr 'ii < ' a" ; 1s.. per ae o ,P ` - tr �+ � � � mlts sh 11 b 3 bt ? �;;�. 1.�R1 �rhr t ugii;.,the �'�at. t» �t � rte: "'%t„t l .Cr1�,r, t t t '1o r�i t yof Labor and Indtr` O el°'"-► ....t wor• , wi li,X Abe- inspected by that 'a��eisc '('24,87"0030):4: Permit too: M96-0057 Status: ISSUED Applied: 04/16/1996 1 s .tied: 04/1Y/1996 PLAN CHECK NUMBER mci (o - ocE51 DEPARTMENT ,BUILDING initial review O FIRE O PLANNING O OTHER ,4 BUILDING - final review BUILDING OFFICIAL AMOUNT OWING: CITY OF TUKW.-,., Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PROJECT NAME SITE ADDRESS INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. COMMENT REVIEW COMPLETED CONTACTED INIT: INIT: DATE NOTIFIED 2nd NOTIFICATION 3RD NOTIFICATION APP - OVED RO TED INIT: INIT: yi i /9 I IT: — X51 West() rn 1590 i w vallp� CONSULTANT: Date Sent - FIRE DEPT. LETTER DATED: ZONING: SCREENING REQUIRED? REFERENCE FILE NOS.. UMC EDITION (year): `iL( Pr) ont U I I - lri (o QUIREMENTS ; FIRE PROTECTION: • Sprinklers Q Yes Q No SUITE NO. Date Approved Detectors N/A INSPECTOR: BAR/LAND USE CONDITIONS? Q Yes 0 No BY: (Init.) BY: (Init.) BY: (Init.) 01/07/93 SITE ADDRESS s--c _ SUITE # VALUE O CONSTRUCTION - $ 7z7©.. OD PROJECT TYPE NAME/TENANT ; • 4 +00 / PRINT NAME bu ASSESSOR ACCOUNT # 0005S.0 0050-0Q - -1:' U • - iir 0 WO'K: 0 New /Addition 0 Modifications 0 Repair Other: DESCRIBE WORK TO BE DONE: Re, I 6`6, ( Le -r p tale, emir i TYPE;: :;;; ;. . >: RATING /SIZE ;::.. ;: ``.. " NUMBER OF UNITS . rkAll / .. .. .. . EXP. DATE i.. �)r -'� _ Wa 00 (G 11 or . fr ` ••••■- iil,Rii� .t)hlittt )-00 r e � ti n 4 I fi. • • • • c TtA BUILDING USE (office, warehouse, etc.) A1b NATURE OF BUSINESS: ,ri 1 c iles WILL THERE BE A CHANGE IN USE? No IF YES, EXPLAIN: I L THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes I YES, EXPLAIN: '.I HEREBY CERTIFY THAT I HAVE READ' AND.. EXAMINED :THIS APPLICATION AND KNOW THE SAME .TO BE TRU •• • AND CORRECT, • ANDIAM AUTHORIZED: TO' APPLY FOR. PERMIT BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE ff DATE / 2.&.-/V2_ ZIP 9 �� r, 2'(�7Q> / PRINT NAME bu PHONE 2' Z _ 7 CITY/ZIP L ` v j PHONE 2 6 ADDRESS G moo Thvy/26 -e i - " ADDRESS � ��� Y 1,.., l � � ) , 4 CONTACT PERSON ,007/ ei , k"/ 0° t PROPERTY OWNER 5y00 toe Li 0 Torn / , J (J lGi 'PHONE 2 PHONE 2.&.-/V2_ ZIP 9 �� r, 2'(�7Q> ADDRESS /S'9D/ GCi 4.,,, 4,../ CONTRACTOR ��� // / � ADDRESS G moo Thvy/26 -e i - " ZI ,',3/9/ /� 0 WA. ST. CONTRACTOR'S LICENSE # / /9477?tv v2 EXP. DATE i.. CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER 11 APPLICATION MUST BE FILLED OUT COMPLETELY MECHANI AL PERMIT APPLICATION 7-560 9-96 - 511 FEES (for staff use only) DESCRIPTION BASIC PERMIT FEE UNIT(S) FEE PLAN CHECK FEE OTHER: TOTAL - AMOUNT RCPT # DATE APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED cico DATE APPLICATION EXPIRES 1 1c0 — a0 03/14 /94 MECHANICAL Completed mechanical permit applic tion (one for each structure orFtenant) Two (2) sets of mechanical plans, which ihclude: • Floor plan • System layout • Elevations (for roof mounted equipment), • Heat Loss Calculations Structural calculations stamped.by a Washington State licens required if structural work is.to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. Li Water heate 'and vents are included in the UMC — please include any water heaters or vents beinginstalled or replaced. SU14/1ITTAL CHECKLIST engineer may be , 11; y * hV "4'�jX " ..S t r".'. • - .� f � i s Y�r •..: , 4'rkA= A *khk**:4 *A*•kAA4 ** A*kkA **kA''i* AAA *AAhAAAk:4A4***h'kk *:44A** CITY or TuKw1:L.A.. Wfa TRAO;il•ia.'i' * AA* kkA*: 4 r: A* 4 A Ah �k�,I1 f[lAN fllZT'.NumhicSr`. 9t/003990 Amount: 60.'38 04/16/9% 13 Payment Me•i;liVii: CHIICK Notation. NOR fHW1 5 r Wo In i t: SLR Nerrni't. Now 06-•005? •Cape: IJ- MECHAN MECHANICAL P1J l4I•f P r'-c:e 1 . No . 000500-0030' Site Address:. 159,01, WEST •Vfal..LEY AY Total Foos!: t&0.38 Thit, Pavmenfi 60..38 Total. ALL flats,: 60.38 A** AA* **k *A•A*AP•A *AA*•k** **A* AAA*4;A* *•A.•AAk14•A*0**l.**A**•*k•A•** A* (account: Code 000/345,830 000/3;22.100. I)eecriptian PLAN CHECK -• RES MECHANICAL - RES Amount 40.30/ GENERA TOTAL CHECK CHANGE 4726A000 60.38 60.38 60.38 0.00 15 :02 Pro ect: _i. Type of inspection: Address: Date called: Special instructions: Date wanted: / `e :2 / ° p.m. Requester: � , Phone No.: i'.:_: • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Receipt No.: INSPECTION RECORD Retain a copy with permit (206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: • $42.00 INSPECTION S EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: r COMMENTS: i / 5l• A iejr41L./ �+ / ..� .,41-- /1iuv d.� .0.1 rill it r / d - .il .,. 7-' d...► 0 .. - /' r / / 4/ �' 4 j ��1 f ' 644.171,074,7-7 1 h ai 4 , / 1. !YoCJ z40 (4», h • . .2 -- E34` S / s - //. 5OO `" /Z C__/,12:2S5 / 45-eC J ` s- G/ ,‘,.• ee ' �� l d /G / 66, • Date wanted: A, ( fl!/14 --" -.s i Cl S . 5 � W P .m. C � i / � . .tea / . ✓r p 17 `, ( �^ e/V ✓ rl // .02400fra 14.40// 4r PI�, 1 JD Project: 6 v w :e Type of inspectlori: F 0, Address: 15q o1 u3 \jay.Q vi Date called: „Li- — 5 - 3 f Special instructions: fl% 1.e Y Date wanted: g /r�� co 5 � W P .m. Requester: 3-O Phone No.: Sot—' t t it t..,, . .... m w,... w . w .. a. owrM. x.. wKOUVaa+»., w•,.+.,,. v........«. rv. w..+ wr.. amw.,.....,..,«,..., uh>+ aa.. s... w.• w... w....+.. nrc« KSVms!0M+8s.'7.t:.17�f:C'?'ktyK INSPEC ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 �. 1 INSPECTION RECORD [ ”` Retain a copy with permit (206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector:% j Date: f (Receit No.: .$42,00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection. Date: U 0 4 FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. By Date 1 4" Permit No. ..... "►.`wry —� 17 5 qo m 3 • ( 473 2T 8" p2i 8g THERMOMETER OW THERMOMETER DRAIN DRAIN e2J. i TANKSTAT LOCATION • COLD WATE MODELS "t00Eas PUMP AND BALL VALVE LOCATION ON MODELS 133 THRU 403 AND 2100 THRU 4031 •' OPTIONAL ON MODELS 5I < THRU 1626 W THOUT INTEGRAL PUMP • Fig. 1 7000 Typical Piping INTEGRAL ON aOOELS 5141620 APPR APR 1.6 1996 13UI . 1NG DIVISION MOS 7 m 4�7 SioMtoo '3S . Meg-.1 4'' f'4G1 2. MG ;a: 09 • LI>atil -) CH • W a 'r- J t o ! l�r 1/(1' 10 • Y IILAt worn lIS BASEMENT - FLO► • R . PLAN JOB: • ENGINEER: — CONTRACTOR: PREPARED BY: EFFICIENT Thermal efficiency 82 %. Highest of any atmospheric tIoiler available today. THERMAL SHOCK PROOF 20 -year warranty against thermal shock damage up to 150 °F. differential. Maximum operating temperature: 230 °F. LIGHT WEIGHT A floor load to 70 lbs/sq. ft. or less. HIGH RECOVERY Cuts fuel costs substantially because the standby and radiation losses normal to other boilers and tank -type water heaters are eliminated. LOW WATER OPERATING TEMPERATURE Operates with water temperature as low as 105 °F. without condensation. STANDARD EQUIPMENT HEAT EXCHANGER • ASME Inspected and Stamped 160 PSIG • National Board Approved • Bronze Headers • Finned Copper Tubes • ASME Steel Tubesheet • Silicon 0 -Rings • 125 PSiG ASME Pressure Relief Valve • Temperature and Pressure Gauge CONTROL • 115V, 60 Hz,1 Ph Power Supply • 115V/24V Transformer • 100% Pilot Safety • Pilot: Electronic, Intermittent Ignition (I.I.D.) • High Limit Control • On/Off Switch • Operating Limit Control • Flow Switch • Economaster II pump Time Delay DATE: 4t GAS CONTROL TRAIN • Manual Main Gas Shut-off Cock • Main Gas Pressure Regulator • Safety Shut -off Valve, Redundant • Control Valve • Firing Mode • AGA Design Certified, ANSI Z21.13 Requirements. CONSTRUCTION Q Indoor Q Outdoor Q Combustible Floor Shield - (Standard on Outdoor) • Vent Terminal • Front Controls Enclosed • Stainless Steel Burners • Polytuf Powder Coat Finish Catalog No.: 3000.202G Replaces: 6.15.93 Effective: 8-15-93 TYPE W FINNED COPPERTUBE HOT WATER SUPPLY BOILERS MODEL INDOOR/ OUTDOOR 4 • •, . W.: ti • n . :W.4141l'A vb •3►.t� , • y M 1tt+ .i1?:. ;'•[�' '.�'� : .w c ; lMk`( - 1 7-7?i y • • ! ;71 • (.11} Uf IUrty ILA rt- o vED APR 1 6 1996 Flo 092e.1 INDOOR MODEL ILLUSTRATED OPTIONAL. EQUIPMENT HEAT EXCHANGER Cl Right Hand Connections Q Mounted Pump CONTROLS Q Ignition Lockout. 0 MBH INPUT REGULATORY AGENCY 0 I.R.I., Industrial Risk Insurers Requirements O F.M., Factory Mutual Insurance Requirements 0 RECEIVED CITY OF TUKWILA APR 1 6 1996 PERMIT CENTER MODEL NO 20 °AT 3Q °AT 40 °AT MODEL NO. TEMPERATURE RISE IN DEGREES F. , GPM AP FT. GPM AP FT. GPM AP FT. 20° 130° 1 40° 1 50° 1 60° 1 80° 1 100° GALLONS PER HOUR W -514 42 1.9 N/A N/A N/A N/A W-514 2518 1678 1259 1007 839 629 504 W-624 51 3.0 34 1.4 N/A N/A W-624 3086 2057 1543 1234 1029 772 617 W -724 60 4.4 40 2.0 N/A N/A W-724 3573 2382 1787 1429 1191 893 715 W -824 68 6.0 45 2.6 34 1.5 W-824 4061 2707 2030 1624 1354 1015 812 Model No. Indoor Outdoor Dimensions Inches Shipping Wt. Lbs. (Approx) Width A Gas Conn. G Flue Dia. K L Input Output Input Output Less Pump W /Pum, W -514 511.5 419.4 511.5 419.4 32-3/4 1 10 25 -3/8 475 530 W-624 627.0 514.0 627.0 514.0 37-1/2 1 12 29-1/2 485 540 W -724 726.0 595.0 726.0 595.0 41.5/8 1 12 34-1/4 635 690 W-824 825.0 676,5 825,0 676.5 45 -3/4 1 14 38.1/2 645 700 TYPE W HOT WATER SUPPLY BOILERS MODEL O OUTDOOR MBH INPUT 29.1 /2---• 143/4 57 3 GAS 44 1/8 .0 BOILER RATE OF FLOW AND PRESSURE DROP INDOOR OUTDOOR COMBUS E FLOOR SHIELD 19.1 /2• BOILER RECOVERY RATES �— O PTIONAL PUMP ��CONN 14 -1/2 10 4 - 2.1/4 OPTIONAL ON INDOOR F. No. 1256.0 NOTES: All dimensions are in inches. Ratings shown are for elevations up to 2000 feet. Elevations over 2000 feet ratings should be reduced at rate of 4% for each 1000 feet above sea level. Raypak, !no., 31111 Agoura Road, Westlake Village, CA 91361.4699 (818) 889-1500 FAX (818) 889.4522 Utho In U. S. A COMMERCIAL BOILER MODEL W SUGGESTED SPECIFICATIONS CATALOG NO.: 3000.90B Effective: 3.01.93 Replaces: 4.01.92 A. GENERAL 1. Provide Raypak Model Copper Fin Tube Hot Water Supply Boller(s) for use with a storage tank with a rated Input of BTU /hr. and a GPH recovery at deg. F. rise, when fired with gas, BTU /Cu. Ft., specific gravity supplied to the boiler at 14.0" W.0 Max. 2, The boller(s) shall be design certified and tested by the American Gas Association Laboratories with a listed minimum thermal efficiency of, 82% and shall bear the ASME stamp and be inspected and approved by the National Board for 160 PSIG working pressure complete with Manufacturer's Data Report. 3. The boller(s) shall be equipped with a 125 PSIG ASME Pressure relief valve, piped by the installer to an approved drain, and a temperature and pressure gauge. 4. The water tube heat exchanger of the boller(s) shall be of the single bank, horizontal grid design with integral copper fin tubes, each end of which Is rolled into an ASME boiler quality steel tube sheet and sealed to 160 PSIG rated bronze headers with Silicone "O" rings, having a temperature rating over 500 °F. The low water volume heat exchanger shall be explosion proof on the water side and shall bear a 20 year Warranty against "Thermal Shock" caused by boiler operation with large changes, not exceeding 150 °F between the water temperature at the boiler Inlet and the boiler outlet temperature up to 230 °F maximum. The headers shall be secured to the tube sheet by stud bolts with flange nuts to permit Inspection and maintenance without removing external piping connections. The heat exchanger shall Incorporate "V" Baffles, between the tubes, to insure complete contact of the external tube surfaces with the products of combustion. Integral pump mounted to return header optional. 5. The boller(s) shall be capable of operating down to 105 °F without condensation. 6. The light weight, high temperature, Interlocking castable combustion chamber liner shall reduce standby radiation losses. The corrosion resistant galvanized steel Jackets shall be finished with a baked on powder finish, suitable for outdoor Installation, and shall incorporate lowers, in the outer panels, to divert air used for combustion, past heated surfaces reducing Jacket losses and increasing unit efficiency. 7. The stainless steel alloy burners shall be of the raised port design with fixed primary air ports, capable of quiet ignition and extinction without flashback at the orifice at firing rates between 20% and 100%, and mounted in a slide out burner drawer for ease of Inspection. 8. The boller(s) shall have a floor loading of 70 Ibs/square foot or less. 9. The boller(s) shall be completely assembled and fire tested prior to shipment from the factory. B. PILOT CONTROL SYSTEM 1. The boller(s) shall be equipped with a 100% safety shutdown on loss of pilot flame. The pilot ignition shall be (a) (b) (c) (a) Standard all Models Sizes 133-263 a standing (continuous burning) pilot with thermocouple flame supervision. (b) Standard all Model Sizes 403-1826. an electronic Intermittent Ignition system with electronic flame supervision having response time. Standard all Model Sizes 2100.4001. an electronic intermittent ignition system with electronic flame supervision having response time, requiring a manual reset on flame failure. (c) a nominal 0,8 second flame a nominal 0.8 second flame C. FIRING MODE 1. The boller(s) shall be equipped to (a) (b) (a) Provide full modulation of the gas Input to any Toad condition as low as 20% of the lull rating of the boiler (5:1 ratio) without flashback, burning at orifices or Improper combustion. (b) Provide on/off control of the gas Input to the boiler. In addition, all gas control trains must have a redundant safety shut off feature, main gas regulation, shut off cock and plugged pressure tapping to meet the requirements of ANSI 221.13. D. BOILER CONTROL 1. The boller(s) shall be equipped with an operating limit and high limit control. 2. A flow switch, mounted and wired shall be provided as standard on Models sizes 183.4001. 3. An energy saving pump control relay (Economaster II), mounted and wired shall be provided for system efficiency. 4. Additional controls. Raypak, Inc., 31111 Agoura Road, Westlake Village, CA 91361.4699 (818) 889-1500 FAX (818) 889.4522 Litho In U.S.A. FEATURES L g3MIU'al A. 0. Smith storage tanks are ideal for use with gas -fired copper heat exchanger equipment and other A. 0. Smith hot water systems for storage of any potable water at temperatures of 180 °F or lower. GLASS -LINED - For long life. Tank will not add rust to water. Interior surface is coated with glass and nickelous oxide. SIZES FROM 80 TO 1,000 GALLONS - All tanks in table on reverse side are normally car- ried in stock. ASME construction available on all except 120 gallon size. HORIZONTAL OR VERTICAL MOUNTING - Except TJ -80 which is vertical and TL -500 which is horizontal. MAGNESIUM ANODES - For extra protection. TJ -80 and TJ -80A, meet ASHRAE 90A -1980 (1982 requirements) and are jacketed and insulated. All tanks except TJ -80 models receive one coat of paint on external surface. T -80, TJ -80 and T -120 tanks are shipped in cartons; all others are skid mounted. Stock tanks T -140A and larger have threaded leg sockets on one head for vertical installa- tions. (Except TL -500). WORKING PRESSURES Tanks tested at test pressures assigned in ac- cordance with working pressures shown in table on reverse side. OPTIONS • ASME and National Board Certification sheets • Tank cradles - -- minimum of two per horizontal tank required. Revised September 1981 LARGE VOLUME N HOT WATER STORAGE TANKS i 4d:ttaZiE_:id.c (ON ASME CONSTRUCTED TANKS) NOTE: Custom line tanks available to meet military specifications, various work- ing pressures, lifting Tugs, handholes, manholes, special opening sizes or locations. Refer to sheet A 411.0. LIMITED WARRANTY OUTLINE If the tank should leak any time during the first 5 years, under the terms of the warranty, A. 0. Smith will repair or replace the tank; installation, labor, handling and local delivery extra. THIS OUTLINE IS NOT A WARRANTY. For complete information, consult the written warranty or A. 0. Smith Water Products Company. A 401.0 F M P T M;FRONT• N:REARt R --.. B / +r!y DATA PLATE ague G " r F P T i'r' o F ANODE AI P i 1 G\ �) . '4 ■ 1 O G R L G (REAR) is + 1: DATA UNDER PLATE COVER t\ ∎ �� I f F C A ANODE A NODE ! F I c.. DATA PLATE x ! O P Fti — K * E N ~ N G (T120) G (780) t I FIGURE 1 -TJ-80 & TJ•80A FIGURE 2— T -80, T -120 f / E Insulated Jacket NOTE: T.120 Shown 1 T -80 Equipped with one anode G (REAR) ROUTS " ' REAR) C THREADED LEG SOCKETS j1 I / F H / IT I ANODE F ANODE DATA PLATE D F F G • + \ ' S( L A 0 I o SIZES NORMALLY CARRIED IN STOCK Ky T 1— E FIGURE 3 T•80A thru T -1000A TL•600 — Horizontal mounting only. H nn No leg sockets. Modal and Approk, GPacin' (U. S. Salmi Approx. Om All Dimensions (Inch~ Dia. a Length) Working Preuwe bill Appeal'. Ship. Weight ILbs,1 Sea Fig. DIMENSIONS IIN INCHES) A a C D E F 0 H J K L M N P R TJ40 STD. 26112 x 491/4 150 236 1 261/2 491/2 — 323/4 181/4 2 3/4 — 121/4 31/4 381/2 2 2 — — TJ•80ASME 261/4 x 631/2 126 369 1 261/4 631/2 — 46 16 2 3/4 — 7 31/4 613/4 2 2 — — T40STD. 20 it 821/8 160 170 2 20 611/2 2 — 7 2 3/4 461/4 10 31/2 — — 31/4 4 5/8 T-80 ASME 20 x 615/8 125 204 2 22 47 2 — 10 2 3/4 481/4 19 9 8 1/4 21/2 8 1/4 T.120 STD. 24 x 65 150 221 2 24 643/8 21/2 — 61/2 21/2 3/4 341/2 151/2 11 — — 31/2 4 5/8 T•140ASME 24 x 761/4 126 410 3 24 75 2 — 11 21/2 3/4 261/2 171/2 11 8 3/16 — 4 5/8 T•200STD. 30 x 72 150 442 3 30 703/4 2 — 13 21/2 3/4 281/2 101 /2 13 11 1/4 — 4 5/8 T•200 ASME 30 a 72 125 447 3 30 70 3/4 2 1/2 — 13 2 1/2 3/4 20 1/2 19 1/2 13 11 1/4 — 4 6/8 T•350 STD. 36 x 871/2 150 620 3 36 861/4 21/2 — 141/2 21/2 3/4 30 21 141/2 133/8 1 — 4 5/8 T•360 ASME 36 x 871/2 126 629 3 38 861/4 21/2 — 141/2 21/2 3/4 30 21 141/2 133/8 1 — 4 6/8 T.400 ASME 38 x 971/8 125 672 3 38 967/8 21/2 — 14 112 21/2 3/4 30 21 141/2 133/8 1 — 4 6/8 TL•500 ASME 36 x 121 3/4 125 841 3 36 120 1/2 — — 17 3 3/4 32 1/2 23 1/2 17 — — — 4 5/8 TN•500 ASME 42 x 68 125 813 3 42 87 1/8 2 1/2 — 18 3 3/4 33 1/2 24 1/2 13 18 2 — 5 7/16 T•500 ASME 48 a 73 126 061 3 48 72 1/0 3 — 19 3/4 3 314 28 3/4 24 10 3/4 18 2 1/2 — 6 7/16 T•750 ASME 48 x 1067/8 126 1287 3 48 106 3 — 193/4 3 3/4 263/4 24 103/4 18 21/2 — 6 7/16 T•1000 ASME 48 a 137 3/4 126 1655 3 48 138 7/8 3 — 19 3/4 3 3/4 26 3/4 24 19 3/4 18 2 1/ — 6 7/16 SUGGESTED SPECIFICATIONS Glass lined storage tankls) shall be A. 0. SMITH glass -lined storage tankls) or equal, Tanks shall be X "and have a nominal ___.___" capacity of gallons. Tank(s) shall have threaded openings as shown on drawings. Exterior of tankls) shall be thoroughly cleaned and painted. Interior of tank(s) shall be glass lined with an alkaline borosilicate composition which has been fused to the steel base by firing at a temperature of 1600 ° F. Glass coating shall be continuous over the entire Inner surface of the tank. Cathodic protection shall be provided. They shall have a working pressure of psi. Tank shall have (number of) tank cradles. Tank shall have a five year limited warranty as outlined in the written warranty. A. 0. Smith McBee, South Carolina Water Products Company Stratford, Ontario El Paso, TX Seattle, Washington A Division of A. O. Smith Corporation Veldhoven, The Netherlands A. 0, Smith Corporation reserves the right to make product changes or improvements at any time without notice. A 402.0 © A. O. Smith Corp., 1988 Printod in U.S.A. ?„314�fi Jan 31, 1997 MONTY PEIL 2800 THORNDYKE AVE WEST SEATTLE, WA 98199 RE: BEST WESTERN Dear Permit Holder: Our records indicate that on Dec 17, 1996 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechanical Permit Number' M96-'0057. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Dec 17, 1996. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. Sincerely, cte Led/J(6-7o City of Tukwila Kelcie J. Peterson Permit Coordinator Department of Community Development FILE COPY John W Rants, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 ' :'= ;' '% •.. '. ;?; •R *Illi7ION NO 1361;..;i; �':: ;' ; NOP;THWH1.O3R2 EFFECT ::W1 , K BATE X AATIONDATE.' 1.x . / 22 !•99§ 1;2/22 f O P". ''' . . ..y,.ViiV %i`�v/ti.J it � itir�vV. i✓. �rr!' i.! fy�/ll �rnr,!. i!!,! �1 �. !�r.!..i ✓.i�vN! /rr!!! %✓vlrl.�/' ✓✓lir✓ /. i!! ! /.ii %i.[ %rv�.%✓iiisNJ! / /ic.��f i!. ✓ j% isrv v y_ tr✓ ivnivii✓ i' nri e,i✓vy_vN.vy ✓!✓Y_`�v_!iY` Y oh! i 7, + iy ivi✓ srftr v,_vri✓ veilwniniriir,.rl-em,i✓iin!ii' " %iii.Jri.'vil.:lllie DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HERFON IS REGISTERED AS PROVIDED BY LAW AS A :': C. • NOWTHWEST, t4 ' H TR n I NC / DAV I W11 2 £x.00 'THORNDYKE . AVE W SEATTLE WA .• • 9819? E ;'. STATE OF WASHINGTON F625.052•C