Loading...
HomeMy WebLinkAboutPermit M96-0066 - TUKWILA CHEVRON°Pioo LU r*J Ia % r t; flNWU ■ . City of Tukwila L,, (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: Type: Category: TENANT OWNER CONTACT CONTRACTOR UMC Edition: 199.4 M96 -0066 B- MECHAN NRES Address: 10805 EAST MARGINAL WY S Location: Parcel #: 032304 -9064 Contractor License No: HUSSMC *134,7Z TUKWILA CHEVRON 10805 EAST MARGINAL WY S, TUKWILA WA PRADEEP SANDHU 2023 217TH PL NE, REDMOND WA, 98053 GORDON GRIGGS 7272 FIRST ,AV :5;,: :SEATTLE WA 98108 :V HUSSMANN:CORPORATION 7272 FIRST;AV S, SEATTLE WA. • * *, * ** * * * * * * * * * *., * * * * * * * * * * * * * * *• * * * * * * ** *)44(4 * * * * * * * * * * * * * * * ** Permit Descri t1on :. INSTALL, THREE .REFRIGERATION` SYSTEMS FOR WALK -IN COOLER, FREEZER AND ICE; MAKER. k*** *A k A'k* k•k * **44* * ** **** ** k** k*** *** *** *A* * ** ** *•k** * ** k k * ** ilr * *fir * ** ** L Permit,Center Authorized Signature Signature: Print Name:_ MECHANICAL PERMIT Valuation: Total Permit Fee: Status: ISSUED Issued: 06/05/1996 Expires: 12 /02/1996 Phone: (208)624 -2697 Phone: 206 763 -9050 Phone: 206 763 -9050 ,368.00 76.81 D ate • I hereby :certify .•that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this ..work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of, work. I am authorized to sign for and obtain this: building peyi it Date: Title: �''�ic,,t ..S This permit shall become n,ul7.and void if.the'..Work'is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. I 0 ia5 EAST MARGINAL : W. Address Suite Tenant: TIII::WILA CHEVRON Status: I'SSUECD. Tyne: L1- MECHAN Applied: 05/23/1996 Pl #:. 032304 -9064 Issued: 06/05/1996 •k •k •k A •k A .k •k •k •k'k •k -k •k •k - k -,k •k •k k •k •k •k •k k •'. •k k •k •k •k t •k F k 'k -k •k k •k •k •k .k k k •k k •k -w •k •k 4 k k k •k•k A k k •h k k •k k k k k k •k 'k •k k 'k Perm i t Conditions: 1. No changes will be made to the . plans unless .approved by the Architect or En.zineer ;ind th.e..lus;w.l.J Bui idinq Division. All. permit:s." it p .ctfa r;ei,ar d = ' an ti a ip plan. shall be . a v a i l a b l e : at the ,01� •` :.1 n to °"'pr 10r to the - t tarpt of any con- struction. Thes'e 6ment s:f are te�; be main`tai,rre ":ti. ar ►d avail- able until tin `1 '1n pectrorj';appr oval is +air ante4 ?, All constr uctlon to ;be dotrefin canfarman`ce with approved plans ;and .,eauireMentw. cat the,Unit r`'m iu Idin9;,1 ode' 994 Edition) d;' amernd'ee1t Uniform ' Mechin'1c: 1. Ccde' t1994. Edition), and Wa,�h, ngton State Eb'er g' ( o de , t 1'' '4 Edition) r r . ; 1 4. Va "1iti1 °tv at ' Permit 1 he issuance. of a permit o't eoprovat1 of code or , of ,e p1 any� pciti ida0bri t .�tfld' t'Onrl�ut'a.E:iatti , -h;i11 hot..be c'h tr t e tl tof e a ta pe�i•m i t ` ~;' .tu an any v ib`T�lt edr at o an f" `'the or�� ov i :,z on ot' ) thie , Y1app ova f of , a 'u i 1 tl i r.' nv • t e' apt `i'r a n c o f the. l u i f i i `i: p - "` a t q j` Ix e. r' ;�� t; i c rr•-. No permit i t }tp� e �. uoii l ri 9 i ve" tatlt.hor'i tv to v itiTate,, Of ne•1' f rac tI 4:�r�ov i .i an3�. af `t 1 l is •: 0c:9#/shall " bey, valid':; f• ..... }; a ` 5. Mi '1 PACIUFEh'S IN' 1'ALLA TIOfN INS1RUC,Ti0tr;'i� REWIRED ow, SIT ,F9kITHE BU - IN::ER F T41PM� REVI:E'W . , 6 'E 1 11 per ~r+i,it,.' ' :ha l'l ,�tei obta4ned thr,"otiQh the WAhingkon • ` -s t iae 11 V 1.ai'Ql 0= Lak±,oi a`nd tl ndu `tr �i " e_. And all e l e t , i a l weak, w l Lvbe,, in rec tedj pv th at,, agent v,,(,24 - 630) f �, AMOUNT OWING: 4. to .� CONTACTED GOT 6 ()c 1 CYE5 OS e hd. VIA-/ DATE NOTIFIED ( 3- �LQ BY: (init. 2nd NOTIFICATION BY: (Init.) 3RD NOTIFICATION BY: (Init.) PROJECT NA E Tu CheviOn SITE ADDRESS_. e f fc 5 SUITE NO. 1 CYE5 OS e hd. VIA-/ Mechanical Permit Application Tracking r Ea5- 00 PLAN CHECK NUMBER Mai, - 00(pto INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT: BUILDING - initial review %FIRE O PLANNING O OTHER XBUILDING - final review XBUILDING OFFICIAL DATE IN 512 REVIEW COMPLETED CITY OF TUKt4k, -t Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 ti(/ DATE .: .APPROVED (ROUTED) INIT: /4 INIT: INIT: INIT:�h... INIT: re w SCREENING REQUIRED? 0 REFERENCE FILE NOS.: UMC EDITION (year): REQUIREMENTS / COMMENTS CONSULTANT: Date Sent - Date Approved FIRE PROTECTION: 0 Sprinklers U Detectors ON /A FIRE DEPT. LETTER DATED: /(J /C. INSPECTOR: S'l 1 ZONING: 'BAR/LAND USE CONDITIONS? U Yes U No Yes O No 01/07/93 SITE ADDRESS ,SUITE # 1 c5 6c) 5 , MAC t ,...t,4 L.. \NMI- S. , VALUE t0 O STRUJ N - $ / � = , PROJECT NAME/TENANT G=l-/t �V t%% 7 ASSESSOR ACCO NT # et O - , '' 1 ADDRESS ZiJ A * '1 ' _- • AyL-' . i `x-41 - k \.4 . 21P �� (� .f t1 WA. ST. CONTRACTOR'S LICE SE # u S c TYPE OF WORK: h` New /-- ❑' Modifications • ❑ Repair .0 Other: , .a� � DESCRIBE WORK TO BE DONE: s T h L . l . _ K - j E ' to rJ G'C --- Tel a = -- /4&w . S li.s - A - s - ( 1 3 ) 1 7le ',• �P` �Y1,474 , AA: . t ' . '' P... ,',.'.. y '� NU AA E '0 r r�.r �� .� \VA,U' -t . A%''':' ! -" ' ./ ! ty, r.�Y:'`i ��"Atae jw1•'" � � v 1 , j q ` ''�7' -[ - 3 lJ ,, ,� .Y ^',. • uldi W.M �n �' �P},it:'"y�`?� X611 "1 � ..1 Ch�ti�o ".xS,�., ^5. BUILDING USE (office, warehouse, etc.) , — Y2/IC& JT .dTh e2 1.3 NATURE OF BUSINESS: . ills l L— -6 6 WILL THERE BE A CHANGE IN USE? ❑ No ❑ Yes IF YES, EXPLAIN: , WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? . ❑ No D Yes , IF YES, EXPLAIN; • PROPERTY OWNER 5ls. Y`! 0 14 sj pe, ni t P PHONE ADDRESS 2.073— 2/ � A . , Z', ZIP rD6 CONTRACTOR s K,64„„i ::7, PHONE ' 46. j r 5, ADDRESS ZiJ A * '1 ' _- • AyL-' . i `x-41 - k \.4 . 21P �� (� .f t1 WA. ST. CONTRACTOR'S LICE SE # u S c EXP. DATE jJ . y 9..C. ' D - I TIO , , B': It ;ERMITIFEE " .'. UN•.S' R'' i.iPi } tI E . . 1V ?. • '. f ,, j ,' 3 ', F <il, e �YcFZ ” a ' ''' ' gq 9 ;•'A OUNT *( r: gfiF Mft':DA:T,E JE`�.." RAM5 r ffiar F r ' • " 1'r,4 ..' i `cf4� ': t 4 ,...:": i u... ...PAL' N ' „<L .We' n � 1 l�iEcdorsal M M JAN 04 '96 03 :29 M UKWTI_R DCD /PW CITY OF TUKWILA Department of Community Development ; Building 6300 Soulhcenler Boulevard, Tukwila WA '98188 (206) 431 -3670 .7pREgS -000 PLAN CHECK m9 NUMBER frOOfo b APPLICATION MUST BE FILLED OUT COMPLETELY BUILDING OWNER OR AUTHORIZED AGENT PERMIT CENTER P.2 MECHA i.CAL PERMIT APPLICATION FEES (for staff use only) PRINT NAME/ ,0.0/v cc; AD DRESS CITY/ZIP 9ft l / ill /e z - ie7 �� �� ���� .5 PHONE L , 'S ' CONTACT PERSON 7 � y z), APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review, BUILDING OWNER/AUTHORIZED AGENT if the applicant i other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from thlTATEFty owner authorizing the agent to submit this permit application and obtain the permit will be requlred'as part of thin submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical'Code (current edition). No application shall be extended more than once, if you have any questions about our process or plan submittal requirements, please contact the Departmg8Community Development at 431.3870, DATE APPLICAT A ED (Jr " 1 F ' ATE APPLIG a ATIO EXPI S • CC � � 9 - MAY 2 2 1996 " ► • k AA* A• kk• kJr ** *•A4AA * *:h * *Jf•k** *k* f k* k•* k• k* kk **:��A****** * *k•* C]:.TV OF tUK ILA. WA.' (n(n TU(t„rhIT * *:1•k�i * * ** * * *** * *A * * * *k A r �Vltka* :•**•kk•Ak*k.A!*** *•*•4k.**k l'RAN8MIT Ni i ber.: 96004220 :Amaun't: 76.01. 06/05/96 11:39 . Puvmcnt Methadc CHI L1( Notation: 1•IU33Mt4NN Init: SLO .Perm ii; 'Na: M96-0066 Type: Ll-MECHAN MECHANICAL PERMIT Parcel Na: 032304-9064 • Site.Ad aces: losoti_EF.Sr.MNisiN(I. tot . Tut.R.1 Toe" 76.81 This Taymrnt 76.81 Total ALL Pinta: 76.81 Balance': .00 ** *k**k **k *A *k **kk* *k*k'.**k k*• A•• k* A• A* * **•k *A **A*k ****•k** ** ****khk* . Account Code: be c;r.i pt i an Amount 000/345.830 PLAN CHECK •- NONRE8 15.36 000 /322.100 MECHANICAL - NCNRE:i 61.45 ProJec h. , n �� �rte..‘ /.J0... Type of insp ion: Address: it) b `1�a.. Date called: . )-- Special Instructions: /r'Date (/ wanted: 8 i/ 3 m. p.m. Requester: Phone No.: ' 9 — 306 Z.,-- INSPECTION NO. 1 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 r4 1 :. PERMIT NO. __(2Q6_ 43 -3670 COMMENTS: �.-- -- { Inspector: Date: $ i r 3 / 9 (o Approved per applicable codes. Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Projects ,/ -lo e4d Address: (, /� Type of InspectiA:� c_./,/ / p Date called: Special instructions: Date wanted: Requester: Phone No.: 11 pproved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Corrections required prior to approval. COMMENTS: $42.00 REINSPECTI • FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: Project t�w'k Type of inspec : 1 Address: Date called: Special instructions: Date wanted: G 9` �s : Requester: Phone No.: IN PECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: INSPECTION RECORD Retain a copy with permit Date: PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPEC ION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 rwtA lf Roi "I ' rl'ectigke`.�.�C.t. -�.E- called:/ - lci - To Aras Ai ' L W � iS Date Special instructions: -� f RM t T is YO D Date wanted: � _ Q I .m. Req e, t 01 Phone No �7L0 — 9 ost... ' 4 Approved per applicable codes. 1 1 Corrections required prior to approval. COMMENTS: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwil�,�NA X818 PERMIT NO. (206) 431 -3670 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule relnspectlon. Receipt No.: Date: MUSS CORPORATION 1212 FIRSTAVENUE SCUM PO. PDX 101I1 l TVICO -0Q61 U Q ONSSUC' TOILET • • I• OFFICE NALL 100 1 mqo- cxxda 54wok% at-1 EW-ON /o605 E, ma,5, JV4L LAS S. - roWLJIuA , �,,.N . 9610 sAtUtErb 401E4 1 10 RECEIVED CITY OF TUKWILA MAY 2 2 1996 PEHMIT CENTER STOR■ OFFICE Timm C01�� RIS'W 1342 WALK-IN CO JANITOR TOILET :E2ER � IIQ � IF 0 , 1P7 1r 1P7 \P7 I/ 1r � G r Tito, / EXI T EXIT f 00t = TCDP C*-20 ►s 1 kJ Lai/ (Tf 0 2) yr i= t Lces.T to \V1 T'14 Sj et -c_ 2 6 loais..vs Oct 5 NALL 1061 - 5 - 159A SALES A110254 OFFICE DO RECEIVED CITY OF TUKWILA MAY 2 2 1996 PERMIT CENTER c STORA 1104 Atk.f ,,•; 2 OR FREEZER 43 JANITOR 1110 1 RUSSIAN CORPORATION 7272 FIRSTAVENUE SOUTH P.O BOX 10267 W64261 LE. RSV 1342 1--.464— 'Z) ■,/i Lx06.3c:.1-3 \'.I i(4 Lr,c2c p d' ux-ts SAKIblit) ON VP • / obv 1, M47.61 10}4JILL4 \„ I 0 - 3r ; 1 59 ac2 smues Ammo, I'' 1 f(9 1=. - r c ci/J Cril 2 \J 1- 1 -D12-...vi L.9 5 • CI • SEP stotet- ARP g a � Air - Cooled Condensing Units Med./Low Tip. Models R -404A LOW 0I • i tlier-,t to errors and omissions and approval of dOeS not authori:•r: ;fie violation of any L t r adopted code 01 ordinance Receipt Of con - tractor's copy of approved plans acknowledged. B y Date „- .: Permit No. e RIM io - 0:147(a MEDIUM Copelaweld a .,a Economical CFC Solutions Basic Features Receiver Fan Guard BX Conduit Pressure Switches Contactor RECEIVED CITY OF TUKWIL.A MAY 2 Form 3.1110 PERMIT ;; :.. ; • Form 94 -36 -R2 Unite : Model ' ' ; Nu ; : :;" Overall Dimensions �' (Inches) ' ' - '. ' Liquid Line Valve (In.) Suction Line .:P/ " ' Valve (in.) ' Receive; e iv s �< = 4 } • Capacity 1 90% Full , (Pounds), t ` . . APp rox. 1. eight (Pounds) Air Flow CFM Compressor Model No , Len° Length , Width Height J Net Ship V VJAF -012H 28.0 34.0 15.0 3/8 SWT 7 /B,S.WT' 10.3 206 216 860' RS97C1E VJAF -017H 28.0 34.0 15.0 3/8 SWT 7/8 SWT 10;3 226 236 860* CS12K6E VJAF -020H 28.0 34.0 15.0 3/8 SWT 7/8 SWT 10.3 237 247 1,522 CS14K6E VJAF -025H 28.0 34.0 15.0 3/8 SWT 7/8 SWT 10.3 243 253 1,522 CS18K6E VJAF -030H, 28.0 34.0 15.0 3/8 SWT 7/8 SWT 10.3 243 253 1,522 CS20K6E VJAF -035H 32.0 44.0 • 20.0 1/2 SWT 1 1/8 SWT 10.3 296 331 3,360 CS27K3E VJAF -040H 32.0 44.0 20.0 1/2 SWT 1 1/8 SWT 10.3 296 331 3,360 CS33K3E 460- 3 -60': , :, ''' e li e l. c. mu MCA Max °; F u REIM MIS KOMI rim__ Will M1gr.0 20 - CFZ,6,18.4 25 NM - FD 8. aiii 20 13.9 ;;.: "220/240 -1 -50 ec. de MCA ' r. , ax Fuse IIIMIE, 15 M1gr.0 20 - CFZ,6,18.4 25 Moo 8. 25 I . 22.8 , 30 208/230 -1 -60 : ` A Ell Cod MCA J ,. FA -CAV ME 20 -CFV `Ij 20 -CFV 8. 25 -CFV 22.8 , 30 NM 26.1 L40 ME 33.5 W7 -CFV 42.0 60 1 .... 208/230:tUfif Elec. MCA : :Max Code Fuse -TFC 10.2 15 -TFC 10.8 15 -TFC 14.2 20 -TFC 15.8 20 -TFC 17.1 25 -TFC 22.7 30 -TFC 26.0 40 U siN4 2 of 1 +t F5 u3 c•,ad+.F1t. ..1.4, 2 Specif *Models VJAF -012H & -017H have only one fan, Electrical Data Unit,. Number..., VJAF-01 2H VJAF-01 7H VJAF -020H VJAF -025H VJAF -030H VJAF -035H VJAF -040H Notes: laL Specifications /Electrical Data "Elec" code is a part of the model number. "MCA" is minimum circuit ampacity value developed for U.L. This value has a calculated safety factor and can be used for wire sizing. • ' For remote applications over 50 feet, additional receiver capacity may be necessary to assure adequate pumpdown capacity. , AIl phase models use single -phase fan motors. "Amp data for CAV and CFV models is shown for the highest current condition which is at 208 volt. Operating voltage range: 208/230 - - nameplate rating plus 10 %, minus 5% all other nameplate ratings plus 10 %, minus 10 %. HC Series Compact Unit Coolers Compact units with 4, 6 or 8 fins /inch and high performance 12 -inch fans. Broad capacity range from 3,900 to 37,200 BTUH at 10TD. HussmAnn® Unit Selection AIR DEFROST - CAPACITIES & ELECTRICAL DATA FAN MOTOR PERFORMANCE- AMPS, 1 PHASE CAP.- STANDARD MOTOR OPTIONAL PSC MOTOR BTUH WATTS WATTS MODEL NO. 101 TO CFM 115V 208/230V 460V 115V 208/230.460V 115V 208/230V 115V 208/230V HC6A -045 4,500 820 2.1 1.1 0.6 140 100 0.7 0.4 50 HC6A -056 5,600 800 2.1 1.1 0.6 140 100 0.7 0.4 50 HC6A -076 7,600 1,530 4.2 2.2 1.2 280 200 1.4 0.8 100 HC6A -090 9,000 1,640 4.2 2.2 1.2 280. 200 1.4 0.8 100 HC6A -111 11,100 1,600 4.2 2.2 1.2 280 200 1.4 0.8 100 HC6A -135 13,500 2,460 6.3 3.3 1,8 420 300 2.1 1.2 150 HC6A -166 16,600 2,400 6.3 3.3 1,8 420 300 2.1 1.2 150 HC6A -180 18,000 3,280 8.4 4.4 2.4 560 400 2.8 1,6 200 HC6A -222 22,200 3,200 8.4 4.4 2.4 560 400 2.8 1.6 200 HC6A -278 27,800 4,000 10.5 5.5 3.0 700 500 3.5 2.0 250 HC6A -333 33,300 4,800 12.6 6.6 3.6 840 600 4.2 2,4 300 HC8A•050 5,000 790 2.1 1.1 0,6 140 100 0.7 0,4 50 HC8A -062 6,200 760 2,1 1.1 0.6 140 100 0.7 0.4 50 HCBA -086 8,600 1,500 4.2 2.2 1.2 280 200 1.4 0.8 100 HC8A -100 10,000 1,580 4.2 2.2 1.2 280 200 1.4 0.8 100 HC8A -124 12,400 1,520 4.2 2.2 1,2 280 200 1.4 0,8 100 HC8A -150 15,000 2,370 6.3 3.3 1.8 420 300 2.1 1.2 150 HC8A -186 18,600 2,280 6,3 3.3 1,8 420 300 2.1 1.2 150 HCBA -248 24,800 3,040 8.4 4.4 2.4 560 400 2.8 1.6 200 HC8A•310 31,000 3,800 10.5 5.5 3.0 700 500 3,5 2.0 250 HCBA•372 37,200 4,560 12.6 6.6 3,6 840 600 4.2 2.4 300 ELECTRIC DEFROST - CAPACITIES & ELECTRICAL DATA FAN MOTOR PERFORMANCE- AMPS, 1 PHASE DEFROST HEATER PERFORMANCE CAP•BTUH6610'F TO STANDARD MOTOR OPTIONAL PSC ELECTRIC DEFROST AMPS MODEL NO, -251 +20'F CFM 208/230V 460V WATTS 208/230V WATTS WATTS 23011 230/3 46011 HC4E•042 4,200 4,850 830 1.1 0.6 100 0.4 50 1,000 4.4 2.9 2.2 HC4E•068 6,800 8,100 1,570 2.2 1.2 200 0,8 100 1,600 7.0 4,6 3.5 HC4E•084 8,400 9,700 1,660 2.2 1.2 200 0.8 100 2,000 8.8 5.8 4.4 HC4E -099 9,900 11,700 2,550 3.3 1.8 300 1.2 150 3,000 13.2 8.7 6.6 HC4E -126 12,600 14,550 2,490 3,3 1.8 300 1.2 150 3,000 13.2 8.7 6.6 HC4E -133 13,300 15,800 3,400 4.4 2.4 400 1.6 200 4,000 17.6 11.6 8.8 HC4E -168 16,800 19,400 3,320 4.4 2.4 400 1.6 200 4,000 17.6 11.6 8.8 HC4E -210 21,000 24,250 4,150 5.5 3.0 500 2.0 250 5,000 22.0 14.5 11.0 HC4E -252 25,200 29,100 4,980 6.6 3.6 600 2.4 300 6,000 26,4 17.4 13.2 HC6E -039 3,900 4,500 820 1.1 0.6 100 0.4 50 1,000 4.4 2.9 2.2 HC6E•063 6,300 7,600 1,550 2.2 1.2 200 0.8 100 1,600 7.0 4.6 3.5 HC6E•094 9,400 11,100 1,600 2.2 1.2 200 0.8 100 2,000 8.8 5.8 4.4 HC6E -117 11,700 13,500 2,460 3.3 1.8 300 1.2 150 3,000 13.2 8.7 6.6 HC6E -140 14,000 16,600 2,400 3.3 1.8 300 1.2 150 3,000 13.2 8.7 6.6 HC6E -156 15,600 18,500 3,280 4.4 2.4 400 1.6 200 4,000 17.6 11.6 8.8 HC6E -187 18,700 22,200 3,200 4.4 2.4 400 1.6 200 4,000 17.6 11.6 8.8 HC6E -234 23,400 27,800 4,000 5.5 3.0 500 2.0 250 5,000 22.0 14.5 11.0 HC6E -281 28,100 33,300 4,800 6.6 3.6 600 2.4 300 6,000 26.4 17.4 13.2 A ' Compact, eas ..o maintain unit coolers for today's and tomorrow's refrigerants Compact Low headroom walk -in coolers and freezers call for a special breed of unit coolers. The new Hussmann HC Series is specially designed with a low silhouette that fits flush to the ceiling. You get more usable storage space for every walk -in application. Efficient, Easy to Maintain The HC Series is also specially constructed for high efficiency and ease of maintenance. Fifty - five models in a wide range of capacities from 3,900 to 37,200 BTUH feature 12 -inch fans for more CFM per unit. Expertly crafted aluminum cabinets and drain pans are designed with easy -to -clean radiused comers. Flexibly Designed for Tonunorow's Refrigerants Designed to be exceptionally flexible for today's applications and tomorrow's, HC Series coils are specially circuited for applica- 2 tions with new refrigerants as well as R -22. Distributors with interchangeable nozzle orifices optimize performance with all refrigerants. Standard Features • More models to precisely and economically meet super- market application needs • Pressurized, sealed coils with heavy -walled copper tube and rippled full collar aluminum fins • Compact, flush - mounted cabinets use only 15-3/4 inches of headroom • Air, electric or gas defrost • 12 -inch fans for optimum air volume and uniform air delivery • Permanently lubricated, thermally protected motors • Die- formed patterned aluminum cabinet and drain pan with easy -to -clean radius corners • Electric defrost models feature efficient coil face heaters, drain pan heaters and a safety ther- mostat • Factory wired fan and defrost controls with convenient terminal strips • All models UL /c UL and UL classified to NSF standards • Rugged protective shipping carton exceeds transit specifications Options & Accessories • 115, 230 or 460 volt, single phase motors • High efficiency 115 or 230 volt PSC motors • Installed TX valve • Long air throw adapter • Polyester fin coating (6 & 8 FPI air or gas defrost only) • Wiring scheme for Protocol and electronic control systems e MODELS TV REFRIO CONNECTIONS OF DIMENSIONS (IN) sva AIR DEFROST ELECT. DEFROST HOT GAS DEFROST TYPE LIQUID SUCTION HG HANGER A 8 C (L8S) HC4E -042 HC4* -042 EXT 1/2 ODS 5/8 ODS 1/2 ODS 4 18 29-1/8 45 _HC4E -068 HC4* -068 EXT 1/2 ODS 7/8 ODS 1/2 ODS 4 27 38 -1/8 65 VI-A HC4E -084 HC4* -084 EXT 1/2 ODS 7/8 ODS 1/2 ODS 4 36 47 -1/8 75 C I) ? HC4E -099 HC4* -099 EXT 1/2 ODS 7/8 ODS 1/2 ODS 4 54 65 -1/8 105 HC4E -126 HC4* -126 EXT 1/2 ODS 7/8 ODS 1/2 ODS 4 54 65-1/8 115 HC4E -133 HC4* -133 EXT 1/2 ODS 1 -1 /8 ODS 1/2 ODS 6 36 72 83-1/8 135 HC4E -168 HC4* -168 EXT 1/2 ODS 1 -1/8 ODS 1/2 ODS 6 36 72 83 -1/8 150 HC4E -210 HC4* -210 EXT 1/2 ON 1 -1/8 ODS 1/2 ODS 6 54 90 101 -1/8 230 HC4E -252 HC4* -252 EXT 5/8 ODS 1 -1/8 ODS 1/2 ODS 6 54 108 119-1/8 245 HC6A -045 HC6E -039. HC6* -039 EXTt 1/2 ODS 5/8 ODS 1/2 ODS 4 18 29 -1/8 50 HC6A -056 INT 1/2 ODS 5/8 ODS 4 18 29-1/8 55 HC6A -076 HC6E -063 HC6* -063 EXT 1/2 ODS 7/8 ODS 1/2 ODS 4 27 38.1/8 75 HC6A -090 EXT 1/2 ODS 7/8 ODS 4 36 47 -1/8 80 HC6A -111 HC6E -094 HC6* -094 EXT 1/2 ODS 7/8 ODS 1/2 ODS 4 36 47 -1/8 90 HC6A -135 HC6E -117 HC6* -117 EXT 1/2 ODS 7/8 ODS 1/2 ODS 4 54 65-1/8 115 HC6A -166 HC6E -140 HC6* -140 EXT 1/2 ODS 1 -1/8 ODS 1/2 ODS 4 54 65 -1/8 125 HC6A -180 HC6E -156 FIC6i -156 EXT 1/2 ODS 1.1/8 ODS 1/2 ODS 6 36 72 83 -1/8 145 HC6A -222 HC6E -187 HC6* -187 EXT 1/2 ODS 1 -1/8 ODS 1/2 ODS 6 36 72 83 -1/8 160 HC6A -278 EXT 1/2 ODS 1 -1/8 ODS 6 54 90 101-1/8 250 HC6E -234 HC6* -234 EXT 5/8 ODS 1 -1/8 ODS 1/2 ODS 6 54 90 101 -1/8 250 HC6A -333 HC6E -281 HC6* -281 EXT 5/8 ODS 1-3/8 ODS 1/2 ODS 6 54 108 119 -1/8 270 HC8A -050 INT 1/2 ODS 5/8 ODS 4 18 29-1/8 50 HC8A -062 INT 1/2 ODS 5/8 ODS 4 18 29.1/8 55 HC8A -086 EXT 1/2 ODS 7/8 ODS 4 27 38-1/8 65 HCBA -100 EXT 1/2 ODS • 7/8 ODS 4 36 47-1/8 70 HC8A -124 EXT 1/2 ODS 7/8 ODS 4 36 47-1/8 80 HCBA -150 EXT 1/2 ODS 7/8 ODS 4 54 65-1/8 110 HC8A -186 EXT 1/2 ODS 1-1/8 ODS 4 54 65 -1/8 125 HCBA -248 EXT 1/2 ODS 1 -1/8 ODS 6 36 72 83-1/8 160 HC8A -310 EXT 1/2 ODS 1 -1/8 ODS 6 54 90 101 -1/8 230 HC8A -372 EXT 5/8 ODS 1-3/8 ODS 6 54 108 119-1/8 275 tModel HC6A -045 may use Internal equalized expansion valve. 4.750 -0- ELECTRICAL CONNECTIONS THIS END O Specifications /Physical Data .750 F.P.T. -/ DRAIN CONNECTION KNOCKOUTS FRONT AND TOP OF UNIT C 0 0 WIRE FAN GUARDS STANDARD, (OPTIONAL LONG THROW -'-- 6.375 ADAPTOR) 15.835 L_ REMOVABLE SERVICE PANEL BOTH ENDS 15.000 13.750 -+l INLET CONNECTION SUCTION CONNECTION 3 24 -hour Production (Lbs /Kgs)t Air - Cooled Unit Water- Cooled Unit Air Temp. Water Temp. Air Temp. Water Temp. °F 50° 70° 90° °F 50° 70° 90° °C 10° 21° 32° °C 10° 21° 32° 70° 680 600 540 70° 650 570 500 21° 308 272 245 21° 294 258 227 80° 640 560 500 80° 640 560 490 27° 290 254 227 21° 290 254 222 90° 590 510 440 90° 630 550 480 32° 267 231 199 32° 285 249 217 24 -hour Production (Lbs /Kgs)t Remote Air - Cooled Unit Air Temp. Water Temp. OF 50° 70° 90° °C 10° 21° 32° -20° to 70° 620 540 480 -29° to 21° 281 240 217 90° 600 520 460 32° 272 236 209 100° 580 500 440 38° 263 227 199 Air - Cooled or Water - Cooled Model Cube Size Condenser Ice Production Lbs /24 Hrs Power kWh /100 Lbs BR -0600A Regular Air 475 6.7 BR -0601W Regular Water 510 5.5 BD -0602A Dice Air 510 6.2 ID-0603W Dice Water 550 5.1 BY -0604A Half Dice Air 510 6.2 BY -0605W Half Dice Water 550 5.1 Water Usage /100 Lbs of Ice Potable Water: 30 gallons Water. cooled Condenser: 135 gallons Remote Air- Cooled with BC -0895A Condenser Model Cube Size Ice Production Lbs /24 Hrs Power kWh /100 lbs BR -0690N Regular 485 7,2 BD -0692N Re 520 6,7 BY -0694N Half Dice 520 6,7 Water Usage /100 Lbs of Ice Potable Water: 30 gallons Order ice storage bin separately. tProduction for Dice and Half Dice ubes. Regular cube is 7% less than chart and kWh /100 Lbs. Increases 7%. Electrical Entrance s/s FP.T. Inc Making Water Inlet '/r F.P.T. Ice Making Water Drain 17.00" W O AuCS Accessory Knockout locution —1 23,50 3 4.00.. 1.75" — 1/2 F.P,T. Water Condenser Outlet (water - cooled units) 1.56" 1.25" 0.75" 1.56" 30.00" t 10.50 s � sr 3 /4 F.P.T. Bin Drain 400" 1000" 15.00` B -600 Ice Cube Machine C -570 Bin, 606 Adjustable Legs (6.00 "•7.75 ") 20 5.00" 3.25" II 3 /1 EP,T. Water Cottdenur Inlet (water - cooled unite) 0" 44. 0" 6.50" Form 7171B litho in USA, MO/40M/2.95 01995 MANITOWOC Continuing product improvement may necessitate change of speci- fications without notice. SP O Printed on recycled and recyclable paper RWTUV Certified IEC 335.1 IEC 335.244 SOHZ 0 Certified and Rated In Accordance With ARI Standard 810 -91 Test conditions for standard ratings are 90 °F air, 70 °F water, and 30 ±3 psig water inlet pressure. ICE MACHINE ELECTRIC... 208. 230/60/1 Minimum circuit ampacity: Air - cooled — 8.8 amps Water - cooled — 8.4 amps Remote — 9.0 amps Maximum fuse size: Air, Remote, and Water - cooled — 15 amps HACR -type circuit breakers can be used in place of fuses. 220. 240/50/1 also available, consult factory. ce storage bin and 8C -0895A remote condenser must be ordered separately. Consult remote condenser specification sheet for details. INSTALLATION...allow a minimum of eight inches clearance above, behind, and on both sides. ICE MACHINE SPECIFICATION... Model manufactured by Manitowoc Equipment Works having ARI - certified ice production capacity of lbs. per 24 hours at 90 °F. air and 70 °F water temperatures. Cube size will be " x " x Ice machine will include, as standard, a self - cleaning feature consisting of one 10- minute clean cycle and 6 rinse cycles and a condenser air filter (air - cooled models) of aluminum mesh. Filter medium to be dishwasher safe and reusable. Ice machine will also include an ice - thickness control that assures uniform cube size without using pressure controls or thermostats and will incorporate a refrigerant designed for low- temperature application, such as Du Pont "SUVA': Refrigeration system must accommodate future HFC refrigerants without change to system components. For more information, contact our Wisconsin headquarters or the MANITOWOC ICE MACHINE SPECIALIST listed below: C1111110WOCEQUIPMENT WORKS • Division of The Manitowoc Company, Inc. 2110 South 26th St., P.O. Box 1720, Manitowoc, WI 54221 -1720 • Ph: 414-682-0161 • Fax: 414-683-7589 Condenser Model Matching Ice Machine Condenser Electrical Servke' Amperage 2.3 Weight 76 Lbs. K.0495 450 115/60/1 IC-0895 600 or 800 208-230/60/1 1.3 85 Lbs. 8C-1095 1000 208-230/60/1 1.3 92 Lbs. K- 1395 1300 208. 230/60/1 1.3 96 Lbs. K -1895 1800 208- 230/60/1 1.3 108 Lbs. Model Electrkal Sinks' Minimum Circuit Ampacfty Maximum Fuse Size 450 115/60/1 13.4 20 600 208-230/60/1 9.0 15 800 208-230/60/1 12.0 20 1000 208-230/60/1 17.9 30 1300 208-230/60/1 19.1 12.2 30 20 1800 208-230/60/1 28.1 19.3 40 30 Model Line Length Weight R(')- 20•HP81 20 11 Lbs. R(')- 35 -HP81 35 17 Lbs. R(')- 50•HP81 50 24 Lbs. W leo 0 W INSTALLATION INFORMATION AND DIMENSIONS: Maximum Location Distance — combined vertical and horizontal distances from ice machine to condenser must compy with guidelines. Maximum Line Length -100 feet. Maximum Vertical Rise - 35 feet above ice machine. Maximum Vertical Drop - 15 feet below ice machine. To calculate other acceptable horizontal and vertical combi- nations, refer to appropriate remote condenser installation instructions. REMOTE B -MODEL ICE MACHINE '220-240/50/1 or 308-415/50/3 available. Shaded box Indicates 3 phase. Consult factory. HACR circuit breakers on be used In place of fuses. • RWTUV Certified IEC 335.1 IEC 335.2.24 Form 7105.1 soHz Litho in USA, MO/40W4 -93 01993 MANITOWOC Continuing product improvement may necessitate change of speci- fications without notice. Printed on recycled fr tl IM-ElecIrkal I I,•� u + F.P.T. lee Making k3/41 N F.P.T. k. Makin Wa W C .in Typical Installation ol.w,o• Remo. Un. uwa R.hq. Una STANDARD INTERCONNECTING REFRIGERANT L NES 'RT prefix for Series 450, 600, 800, and 1000. RI. prefix for Series 1300 and 1800. Order separately. w ELECTRIC: Electrical power to the remote condenser is intended to be supplied from the ice machine; however, if necessary, a separ- ate electrical power source can be used. 1-MODEL REMOTE CONDENSER '220-240/50/1 or 308- 415/50/3 available. Consult factory. HACR Inuit breakers con be used in place of fuses. BC -0495, BC -0895, BC -1095, and BC -1395 Remote Condenser For more information, contact our Wisconsin headquarters or the MANITOWOC ICE MACHINE SPECIALIST listed below: OfldOWOC WORKS Division of The Manitowoc Company, Inc. and recyclable paper 2110 South 26th St., P.O. Box 1720, Manitowoc, WI 54221 -1720 • Ph: 414-682-0161 • Fax: 414-683-7879 CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 Activity document routing maintenance. MECHANICAL PERMIT Permit No: M96 -0066 Tenant: TUKWILA CHEVRON Status: PENDING Address: 10805 EAST MARGINAL WY S Route: 1 Current Route Line: 2 of 5 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaadaddadadagAaaagaadad daadagaaadaadaadda Packet Units Action Station Initials Status Received Assigned Completed MECH 01 01 C BLDG KEN Approved 05/23/96 05/28/96 05/28/96 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): .00 Overtime Hours(HH.MM): Comments 1[WALK IN COOLERS 2[ 3 [FIRE.. ANY COOMENTS . ? by KEN 4[ 5[ 6[ 7[ 8[ 9[ 10[ F1 =Help, ESC =Exit current screen. 05/28/96 • • SEA TT T SIGNATURE • d RECEIVED CITY OF TUKWILA • MAY 2 2 1996 ISSUED BY DEPARTMENT OF