HomeMy WebLinkAboutPermit M96-0074 - LENIHAN DISTRIBUTING COft LOO - gb U) soD N ungi NVI•FINal City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 Permit No: M96 -0074 Type: B- MECHAN Category:' NRES Address: 18200 SEGALE PARK DR B Location: Parcel #: 352304 -9119 Contractor License No: DESIGL*212DG TENANT LENIHAN DISTRIBUTING CO. 18200 SEGALE PARK DR B, TUKWILA, WA 98188 OWNER LA PIANTA LTD PARTNERSHIP PO BOX 88050, TUKWILA WA 98138 CONTRACTOR DESIGN AIR, LTD. 801 NORTH CENTRAL, KENT, WA 98032 CONTACT MIKE DONOHEW 801 NORTH CENTRAL, KENT, WA 98032 * *•k * *•k * * * * * ** k k ** * * * * * **** * *** * * * ** * * * ** * * * * ** k* * * * * *** *•kilt* Permit Description: CHANGE OUT FOUR HEATING /AC UNITS, CURBS, AND STRUCTURAL MODIFICATIONS. AND ROOFING. UMC Edition: 1994 Valuation: Total Permit Fee: * * * * * **'* *************• k********.************* * * * ** * * * * * ** * * * * * *•k * * * * * * * * * ** MECHANICAL PERMIT. Permit Center Authorize • Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct.. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel'. the provisions of any other state or local laws regulating construction or the performance of work. I ani authorized to sign for and obtain this building permit. Signature:,✓,.�;� Print Name: UrDS Date:, U, Title: l U .c� - S.r_..: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180Aays from 'the last inspection. (206) 431 -3670 Tukwila, Washington 98188 Status: ISSUED Issued: 06/25/1996 Expires: 12/22/1996 Phone: (206) 575 -3200 Phone: 206 854 -2770 Phone: 206 854 -2770 40,000.00 88.75 Addres •s: 18200 SEGALE PARK DR B Suite: Terient: LENIHAN DISTRIBUTING CO, .T : B- MECHAN Parcel•#: 352304 -9119 Permit No.:' M96 -0074 Stor.r,..: ISSUED Applied: 067'17!1996 Issued: 06725/1996 • k• k• kVF• k***• k***-A**'• k**• k.*• k*• k k• k* **** ** * *kkkkkkkkkkkkk•kkkkkkk *F kk•k•k101kkk kkkk.•kk'kk Permit Conditions: . 1. No changes w i l l be made to the plans unless approved by the Architect or Engineer and the,,:.Tui Division. 2. All •permit i aspect i.on t e or'ds , �n.c1�,;` ppr�oved plans •shall be available at the .oh s ite prior~ to th'e`•;'tartof any con- , strUction. These:; documents;r ,'. ae to.. be mairi'tained and avail- a b l e until final - i ns,p'ection ° a'pprov 1 is • ±granted 3 Al 1 constru, :t -Ion t be' done ;i11"eonfo�rmanc 'r i'th a0Opye.d plans and. ,e'tju i rrements of the,. Un i Bu i l;i rig fiCode •,'(1994 Edition )�`: emendie�d, Un if�or m Mechanical . Code '`t';I 994, Ed i t--i on) , : and WashInig,ton State ,Energy - Code ,(1994 Edition) 4 '. 11x l i dai of'' Permit., The . i s nuance;: of a permit or �appr o,raj:. �f plans spec i f i cati`ons, 'aiid' computation, stea l I not bey. strued td be a permit �f`uir', ,or an. «approval of, any v 'alatIon of .a'n`v of "`the provisions of . :the 'building code or• of :,any • othen of dfhance of t► e• Jurisdiction'. No permit p esmMI . gi c1Litvet authority to vi�ilate•'or cancel the .provisions of thi ce ..ha be va li d .. 5. MOUFACTURERp . INSTAL >INS.TRcIc:TIONS 'RE,OUIPED ON SI FO'R;rTH,E f .IUILDI • =INSPEl: TORS REVI <f`W. P.?uf�►bi:nq, . er'tliitCs if `obtained t`hr;ough the 'Seat<tle -M,'. County �Oepar t tmen _apt Pub,l i a;.' Hea i,t'h ` P l unlb i ng f} ...1n .. ~` y the'(; agenk , qin~lu�iti all alas piping t r6'5'47c22A 7. E1et.trica• :Opermits shall be obtained , the Uash`i•ngtor Staii�e, DiYisio :. Labor and Indu 't :and all e1ectr ical wor k. , x will ;be in :pec by that agency ',(248- 6030Y: 3 ReadtOx accessible access t� roof � :mounted equipiiient is 9, Any e: tc+',sed i•n; ulatiun :: backing' mater'lai "'• shall have a Flame Spread' :ofa25 or ,less, and material :hal1:''.bear i.den`ti- fication';howing'the fire rating thereof, AMOUNT OWING: 4 $ CONTACTED SUITE NO. ,- DATE NOTIFIED -as q (40 BY: (init.) 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PROJECT NAME L n 'l�. L ` rth A li SITE ADDRESS 1 'DC) QaOds2_PO[ k ;Dr 13 SUITE NO. ,- PLAN CHECK NUMBER YYIG (a oo J Ll INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. QUIREMENTS / ; COM. MENT DEPARTMENT; BUILDING - initial review FIRE O PLANNING O OTHER BUILDING - final review BUILDING ( � OFFICIAL CITY OF TUKWt Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking :DATE IN ':> to-n-% 2�I REVIEW COMPLETED APPROV I 6 1 (R (2k\ CI C INIT: INIT: INIT; INIT: l( 05" INIT: CONSULTANT: Date Sent - FIRE PROTECTION: FIRE DEPT. LETTER DATED: IBAR/LAND USE CONDITIONS? U Yes U N SCREENING REQUIRED? O Yes Q No ZONING: REFERENCE FILE NOS.: UMC EDITION (year): l l • nr....i�Y'J:': i1" .S^.'.tN .. .�..i.':i� "lr`. .... .:•R: ^-Rt•,- ..� U Sprinklers Date Approved - Detectors UN /A INSPECTOR: 5/Z 01/07/93 SITE ADDRESS ` SUITE # / ;DK./vt- �,, /(? O Sty-', .f �s - .x ,...0,7 , z VALUE OF CONSTRUCTION - $ ✓ yv oo��. ASSESSOR ACCOUNT # ��S - C — 9 i J 9 0 Other: ADDRESS e . u . 0 ,X $ 8 03 0 7 t /p'C•/ /.c.,< 14.�A P ?$ /3�' PROJECT NAME/TENANT /.-.F / /4A., z,,s,7z,.j0 - _ TYPE OF WORK: 0 New /Addition fE1 Modifications 0 Repair DESCRIBE WORK TO BE DONE: L,y.%.,,) v E, D v r ( "'' /J / F 7 0 / c Li :Li i / C 3 `- , fGt;?. r2 /4.'4'.c- ., / /../C. 772.-' C- 77....i . /71 cio, F. G !`:i7 c...i/ 5 fC� o: - /NG . EXP. DATE ZIP ld'�'3'.t ;:::> ::: � :..:.::::::;:: ><: >:«:..> >: I ::::::::: > : >:: ><;� ;� ::: < >�::;:<. >� :::.; <.: ;:�::: ;.::::: NU BER OF UNI S .: :'f RAT NG /SIZE . ....... : .. M :':; >:< <<:: Orb( :pr; c G. oct, o ,v 0 q c ip, £ c,. S A /FL." «rrc -, OTHER: Y 2.J: p 3c°.c, j p.v .v / G-, 54 c L, /o 7-0 ,J e',..4>..... (.., 1 TOTAL - / 1 / / ?:iEu'7z, k C) GCG o 2 ' f(N D (,o i - 1 , £ t.- // - N Cote /_ -t.li - 72 -7 L-- BUILDING USE (office, warehouse, etc.) OF` /GE f w,ti/ci /J5;€ ..- NATURE OF BUSINESS: /-/VA C' 9 /s7 /e 00 „0 /. s :. F5 WILL THERE BE A CHANGE IN USE ? lo 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 54 No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER L A / /� o• LT v Jar ry ti z ../ ,� PHONE ..5 ADDRESS e . u . 0 ,X $ 8 03 0 7 t /p'C•/ /.c.,< 14.�A P ?$ /3�' CONTRACTOR p r. , /G, e .'/ 7 PHONE (s J U ADDRESS , z ) / /C /6�r�'7 . xi C. t . ,,,..;.„2„....„. ,._-�,r=.,v 4 , u'A EXP. DATE ZIP ld'�'3'.t WA. ST. CONTRACTOR'S LICENSE # of---s /6 / . ` _21_2 0 c, DESCRIPTION..;. AMOUNT RCPT :0 :: DATE BASIC PERMIT FEE �... .: UNIT(S) FEE PLAN CHECK FEE OTHER: , TOTAL - CITY OF TUKWILA ' Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER APPLICATION MUST BE FILLED OUT COMPLETELY 6 /7' I HEREBY G!_[ TIFY THAT HAVE READ AND CORRECT, AND I AM AUTHORIZED: BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON SIGNATURE ND EXAMINED THIS APPLICATION: ° A APPLYFORTHI PER PRINT NAME - -1 /6//A f;/ / ADDRESS YL� ,tip. Cf -z- 7/,{ F MECHANV'AL PERMIT APPLICATION zzIA FEES (for staff use only) AND KNOWTH SAM TO BE TR APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER/AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES f� -(--)- 03/14/94 SUBMITTAL CHECKLIST MECHANICAL n Completed mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped b a ashington State licensed engineer may be required if structural work is tone (2 sets) Note: Hood and duct systems require a building permit for the ducts .haft. Water heaters and vents are included in the UMC — please include an water heaters or vents being installed or replaced. • *4'* o1* A4* *4** * *4 A *k *'A•A•A ** CITY O F T 11 K W I L A, NA * s1 * ** * *s1'k•4k,i * *'A *�'s1*'kst* ** A+ TRANSMIT Number: 96004339 Payment Method: CHECK No • Permit Ha: 1196.0074 Parcel No: 332304-91 Site Address: 18:00 SEG This 'Payment • Account Code 000/q45.830 000/322.100 H 8. / 5 *A ksi*** 4A *4 *s1Ah *k * *?4k *A *AA *• *zi * **fist 0i * *�* Amount: TRANSMIT ** * * *st* A *st kst *•A'k *'kti1•ksl *4 * 88.75 06/25/9G 14:18 tatier►: DECS3GN AIR LTD. Ir►it: SLR Type: 8 -MECHAN MECHANICAL PERMIT 19 ALE PARK DR E3 Total For: 88.7 3 Total ALL Pings: 88.75 Balance: .00 A * *•ks 4, A *•A•4 * *** *' * 4. • % * * *k * ***:i *t1•A*A * * * *4 * ** *;4ot *sill•* * *•A *ki i *sl *d*Ai* Oeecription PLAN CHECK - NONRES MECHANICAL w NONRES Amount 17.75 71.00 ProJec ;1�� i I - T of insp p. �- Lr Addre�, / �� ate called: __ Special instructions: ( ate wanted: 01. Requester: Phone No.: INSPECTION. RECORD Retain a copy with perrL CITY OF TUKWILA BUILDING DIVISION 6300.Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Ef e6 PERMIT NO. 206) 431 -3670 Corrections required prior to approval. Inspector:. A i — 7= 7 Date: . . `./ 411 �/�i olomi- $42.01 REINSPECTION EE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedulereinspection.. PROJECT: LENIHAN OFFICES PURCHASER: SUBMITTED BY: DATE: 111YORIC Heating and Air Conditioning SUBMITAL DATA FOR: Approval SEGALE BUSINESS PARK, TUKWILA SEGALE TUKWILA, WA. PO NO: APPLIED PRODUCTS TUKWILA, WA. 06/12/96 aUI RECEIVED CITY OF TUKWILA JUN 1 7 1996 PERMIT CENTER igillYORIV646/19.- Date 06/12/96 Name LENIHAN OFFICES Purchaser SEGALE Order No QTY: SCHEDULE NO: MODEL NO. DESCRIPTION Paget 2 1 1 D6CG060N07946EC D6CG048N06046EC D3CG120N16546EC Submittal Summary Page NOTES: SUBMITTED UNDER STANDARD ARI CONDITIONS 460 -3 -60 Gas /Electric Rooftop Unit 460 -3 -60 Gas /Electric Rooftop Unit 460 -3-60 Gas /Electric Rooftop Unit Company logo gdes here... JYORIC Healing end Air Canalonkg Job Name LENIHAN OFFICES Architect Engineer Purchaser SEGALE Submitted By APPLIED PRODUCTS QUANTITY: 2 UNITS DESIGNATION: scheduie,No: . Units may be Installed on combustible floors made from wood or class A, B or C roof covering materials, 2, Units must be installed out doors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. 'late the unit so that the vent hood outlet is at lease 3 feet above arty forced air Inlet located within 10 horizontal feet (excluding those Integral to the unit). 4 feat below, 4 horizontal feet from, or 1 foot above any door or gravity air Inlet to the building. Subject to - 4 feet from electric meters, gas meters, regulators and relief equlpmenL SUNLINE 2000 rM GAS /ELECTRIC ROOFTOP UNIT Lc) FIELD-SUPPLIED DISCONNECT SWITCH LOCATION FILTER ACCESS- 92.5(0 -7/e we PVC FEMALE CCND. DRAIN (Flee Datal "A1 WIRING ENTRY (Sae D.1.1 "B") BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B • POWER WIRING ENTITY A • CCNTRCL WIRING ENTRY RETURN AIR ACCESS MOTOR SUPPLY AIR D SW ITCH CONDENSER AIR LOCATION OUTDOOR AIR (Economizer) A 1 in. clearance must bo provided between any combustible material and the supply air ductwork for a Distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate, change without notice • Check local code Date 06/12/96 Page3 Order No SEGALE BUSINESS PARK, TUKWILA TUKWILA, WA. TUKWILA, WA. CONTROL BOX ACCESS Model No: D6CG060N07946EC b-M FILTER ACCESS BLOWER ACCESS VENT AIR OUTLET HOOD 0.1/2 GAS SUPPLY DORY 32414 UNIT BASE WITH RAILS Shown separately o blusuete bottom duel op.nin s, power and pre piping connection bcadons. NOTE: For curb-maimed units. rater to the duct limper dimensions 0t the curb lor the proper olio of S. supply and slum alt duct connaosdns, MOUNTING BRACKET FOR DISCONNECT SWITCH (Shipped attached to the blower housing Inside the blower compartment) GAS HEAT C ACCESS GAS SUPPLY ENTRY W IRING ENTRY (See Detail 0) Utilities Entry Data CONDENSER CCMPr1ESTOR ACCESS COMDUST1ON AIR INLET HOW 4a/a 7 CONTROL BOX ACCESS Hole B C D Opening Die. 7/8" KO 2" KO 1/2" NPTI 1- 1/2" KO Use Control Side or Bottom Side or Bottom Front Power Gas Piping Bottom r Total Capacity 63.0 MBH Sensible Capacity 46.0 MBH Efficiency (at ARI) 10.1 SEER Outdoor DB Temp 95.0 F Entering DB Temp 80.0 F Entering WB Temp 67.0 F Leaving DB Temp 58.7 F Leaving WB Temp 57.0 F Power Input (w /o blower) 5.20 KW Elevation `'' 0 Ft HEA I INU PEKFUKMANUL Gas Fired Input @ Sea Level 100 MBH Gas Fired Output @ Sea Level 79 , MBH AFUE 80.5 % • SUPPLY AIX BLUWbK F- XbOKMANUL T otal upp y Ir CF Outside Air • 0 CFM External Static Pressure 0.43 IWG Duct Connection Location Bottom Blower Speed High Motor Rating 1.0 HP Power Input Requirement 0.98 KW ELECTRICAL DATA Dower Supply 46U -3 -6U Total Unit Ampacity 16.7 Amps Maximum Overcurrent Device Fuse Size 25 Amps HACR Circuit Breaker 25 Amps Minimum Wire Size 10 AWG (60 C) DIMINSIUNS & WElUH I Height 33 in Width 82 in Depth 45 in Total Weight (inch factory options) 720 Lbs (. LEAKANUhS Front 32 in Back 36 in Bottom 1 0 in Top 72 in Left Side (filter access) 36 in Right Side (outdoor coil) 24 in JYORIC Healing end Air Canalonkg Job Name LENIHAN OFFICES Architect Engineer Purchaser SEGALE Submitted By APPLIED PRODUCTS QUANTITY: 2 UNITS DESIGNATION: scheduie,No: . Units may be Installed on combustible floors made from wood or class A, B or C roof covering materials, 2, Units must be installed out doors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. 'late the unit so that the vent hood outlet is at lease 3 feet above arty forced air Inlet located within 10 horizontal feet (excluding those Integral to the unit). 4 feat below, 4 horizontal feet from, or 1 foot above any door or gravity air Inlet to the building. Subject to - 4 feet from electric meters, gas meters, regulators and relief equlpmenL SUNLINE 2000 rM GAS /ELECTRIC ROOFTOP UNIT Lc) FIELD-SUPPLIED DISCONNECT SWITCH LOCATION FILTER ACCESS- 92.5(0 -7/e we PVC FEMALE CCND. DRAIN (Flee Datal "A1 WIRING ENTRY (Sae D.1.1 "B") BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B • POWER WIRING ENTITY A • CCNTRCL WIRING ENTRY RETURN AIR ACCESS MOTOR SUPPLY AIR D SW ITCH CONDENSER AIR LOCATION OUTDOOR AIR (Economizer) A 1 in. clearance must bo provided between any combustible material and the supply air ductwork for a Distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate, change without notice • Check local code Date 06/12/96 Page3 Order No SEGALE BUSINESS PARK, TUKWILA TUKWILA, WA. TUKWILA, WA. CONTROL BOX ACCESS Model No: D6CG060N07946EC b-M FILTER ACCESS BLOWER ACCESS VENT AIR OUTLET HOOD 0.1/2 GAS SUPPLY DORY 32414 UNIT BASE WITH RAILS Shown separately o blusuete bottom duel op.nin s, power and pre piping connection bcadons. NOTE: For curb-maimed units. rater to the duct limper dimensions 0t the curb lor the proper olio of S. supply and slum alt duct connaosdns, MOUNTING BRACKET FOR DISCONNECT SWITCH (Shipped attached to the blower housing Inside the blower compartment) GAS HEAT C ACCESS GAS SUPPLY ENTRY W IRING ENTRY (See Detail 0) Utilities Entry Data CONDENSER CCMPr1ESTOR ACCESS COMDUST1ON AIR INLET HOW 4a/a 7 CONTROL BOX ACCESS Hole B C D Opening Die. 7/8" KO 2" KO 1/2" NPTI 1- 1/2" KO Use Control Side or Bottom Side or Bottom Front Power Gas Piping Bottom r JYORIC Healing end Al Conditi ionlog - Ambient Modified - TimefTemperature Defrost Logic on Heat Pumps - Complete Factory Package - Tested, Charged, Wired - Hermetically Sealed Compressor - Direct Drive or Belt Drive Motor Options - Unit Underside Insulated - Spark Ignition - Induced Draft with Post Purge Logic on Gas Fired Units - Bottom or Side Duct Configuration Capability - Low Voltage Relay Board With Terminal Strip - PTC Type Crankcase Heater - Liquid Line Filter Drier - Plug -Type Wiring Harness Connectors for Economizers - Permanently Lubricated Motors - 24 Volt Control Circuit with compressor lock out protection - Manufactured Under the Quality Standards of ISO 9002 - Accu -Sense Changeover Control for Maximun Heating Comfort between Gas & Heat Pump Operation on Dual Fuel Units FIELD INSTALLED ACCESSORIES START ASSIST KIT (Single Phase Units) OUTDOOR THERMOSTAT ANTI - RECYCLE TIMER MOTORIZED OUTDOOR AIR`DAMPER 0 Deg.LOW AMBIENT CONTROLS ECONOMIZER w/ SINGLE INPUT ENTHALPY ECONOMIZER w/ DUAL INPUT ENTHALPY CONTROL THERMOSTAT .� ROOF CURB RELIEF / FIXED AIR DAMPER OUTDOOR COIL GUARD BURGLAR BARS PROPANE CONVERSION KIT LOW NOx KIT HIGH ALTITUDE NATURAL GAS HIGH ALTITUDE PROPANE GAS PIPING KIT SUNLINE 2000TM GAS /ELECTRIC ROOFTOP UNIT D6CG060N07946EC Date 06/12/96 Page 4 Order No GENERAL FEATURES - High & Low Pressure / Loss of Charge and Freerstat Protection Switches - Copper Tube /Aluminum Fin Coils - Easy Access to all Electrical Components - Rigging Holes and Forklift Slots in Base Rails for Lifting - Single Point Power Connection - Powder Paint Finish That Meets ASTMI -B117, 750 hr. Salt Spray Test Standards - Agency Approvals - UL & CGA on All Units - Factory Warranty - One Year on the Complete Unit - Four Additional Years on the Compressor - Four Additional Years on the Electric Heating Elements - Nine Additional Years on the Gas Fired Heat Exchanger FACTORY INSTALLED OPTIONS 4 ECONOMIZER w/ SINGLE INPUT ENTHALPY CONTROL ECONOMIZER w/ DUAL INPUT ENTHALPY CONTROL BELT DRIVE INDOOR FAN TechniCoat CONDENSER COIL OPTION REAR VIEW SIDE SUPPLY AND RETURN AIR DUCT OPENINGS ECOAIOLMZEn MIN 11000 MUER FIXED OUTDOOR AIR OMMei 16000 'so 9002 C E R T I F I E D 4 Indicates a selected option or accessory UNITS WITH ECONOMIZER RAIN HOOD & FIXED OUTDOOR DAMPER HOOD i_ 1110 le•U4 a I yta L ill 1. .. - - _IM_. - -_ ;,,4 1G,14 j - - - �«ru 1 4s,. tatty ---I LH. ENO VIEW 4.$' Hole Opening Dia. Use A 7/8" KO Control Side or Bottom B 2" KO Power Side or Bottom C 1/2" NPTI Gas Piping Front D _ 1-1/2" KO Bottom f r LA-A./WPM, r Intl LJC Total Capacity 51.0 MBH Sensible Capacity 37.0 MBH Efficiency (at ARI) 10.3 SEER Outdoor DB Temp 95.0 F Entering DB Temp 80.0 F Entering WB Temp 67.0 F Leaving DB Temp 58.5 F Leaving WB Temp 56.9 F Power Input (w /o blower) 4.30 KW Elevation '• 0 Ft HEA I IN(U PhKI Gas Fired Input @ Sea Level 75 MBH Gas Fired Output @ Sea Level 60, MBH AFUE 80.9 % SUPPLY AIR IULOWbR PI KI-UHMANUL Total Supply Air 1600 CFM Outside Air • 0 CFM External Static Pressure 0.54 IWG Duct Connection Location Bottom Blower Speed High Motor Rating 0.75 HP Power Input Requirement 0.81 KW ELECTRICAL DATA Power Supply 46U - 3 - 6U Total Unit Ampacity 12.5 Amps Maximum Overcurrent Device Fuse Size 15 Amps HACR Circuit Breaker 15 Amps Minimum Wire Size 14 AWG (60 C) UIMI_NSIONS & WLI(iH I Height 33 in Width 82 in Depth 45 in Total Weight (incl factory options) 695 Lbs CLEARANLtS Front 32 in Back 36 in Bottom 1 0 in Top 2 72 in Left Side (filter access) 36 in ` Right Side (outdoor coil) 24 in JYORIC Healing end Air Conditioning Job Name LENIHAN OFFICES Architect Engineer Purchaser SEGALE Submitted By APPLIED PRODUCTS QUANTITY: 1 UNITS DESIGNATION: Schedule trio: u . Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. 2, Units must be installed out doors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. xate the unit so that the vent hood outlet Is at least: � 3 feel above any forced air Inlet located within 10 horizontal foot ' ` (excluding those Lotegral to the unit). • 4 feet below, 4 horizontal foot from, or 1 toot above any door or gravity air inlet to the building. SubJec SUNLINE 2000 TM GAS /ELECTRIC ROOFTOP UNIT FIELD•OUPPLIED mom/ea SWITCH LCCAllON FILTER ACCESS.' 6y� 32.515 214' NO FEMALE CCND. DRAIN (GM Detail 'A') I WIIUNG ENTRY (See Defal'0') BOTTOM SUPPLY II RETURN AIR OPENINGS (SEE NOTE) B • POWER WIRING ENTRY A • CONTROL WIRING ENTRY A 1 In. clearance must be provided between any combustible malarial and the supply air ductwork for e Distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. t to change without notice - Check local code 41461 from electric melon, gas meters, regulators and relief equipment. TUKWILA, WA. TUKWILA, WA. CONTROL ACCESS FILTER ACCESS BLOWER MOTOR ACCESS RETURN AIR SUPPLY AIR FIELD- SUPPLIED DISCONNECT SWITCH CONDENSER AIR LOCATION 1" OUTDOOR AIR L-. (Economizer) Date 06/12/96 Page5 Order No r, SEGALE BUSINESS PARK, TUKWILA Model No: D6CG048N06046EC OLOWER ACCESS 32.114 32.114 MOUNTING BRACKET FOR DISCONNECT SWITCH (Shipped attached to the blower housing Inside the blower compartment) Veff AIR OUTLET HOOD •-- 1. Me HEAT OAS SUPPLY ACCESS a2•ur ENTRY D GAS SUPPLY ENTRY YWIRING ENTRY (See Detail 'B') Utilities Entry Data CONDENSER COMPRESSOR ACCESS COMOUSRON AIR INLET HOW 4.216 —• T L2 UNIT B,SE WITH RAIL Sham sapral* to alusttets bottom duct opening. powsr and pee piping connectiln locations, NOTE: For curb-mounted units, refer to the duct hanger dimensions at the curb for the proper size at the supply and atom alt duct connections, CONTROL BOX ACCESS JYORIC Heating and Ak ConditIonk+g - Ambient Modified - Time/Temperature Defrost Logic on Heat Pumps - Complete Factory Package - Tested, Charged, Wired - Hermetically Sealed Compressor - Direct Drive or Belt Drive Motor Options - Unit Underside Insulated - Spark Ignition - Induced Draft with Post Purge Logic on Gas Fired Units - Bottom or Side Duct Configuration Capability - Low Voltage Relay Board With Terminal Strip �. - PTC Type Crankcase Heater - Liquid Line Filter Drier - Plug -Type Wiring Harness Connectors for Economizers - Permanently Lubricated Motors - 24 Volt Control Circuit with compressor lock out protection - Manufactured Under the Quality Standards of ISO 9002 - Accu -Sense Changeover Control for Maximun Heating Comfort between Gas & Heat Pump Operation on Dual Fuel Units FIELD INSTALLED ACCESSORIES Notes: START ASSIST KIT (Single Phase Units) OUTDOOR THERMOSTAT ANTI - RECYCLE TIMER MOTORIZED OUTDOOR AIR 0 Deg.LOW AMBIENT CONTROLS ECONOMIZER w/ SINGLE INPUT ENTHALPY ECONOMIZER w/ DUAL INPUT ENTHALPY CONTROL THERMOSTAT 4 ROOF CURB RELIEF / FIXED AIR DAMPER OUTDOOR COiL GUARD BURGLAR BARS PROPANE CONVERSION KIT LOW NOx KIT HIGH ALTITUDE NATURAL GAS HIGH ALTITUDE PROPANE GAS PIPING KIT SUPPLY AIR DUCT CPCNINO (- 17.112 -13 SUNLINE 2000TM GAS /ELECTRIC ROOFTOP UNIT D6CG048N06046EC GENERAL FEATURES - High & Low Pressure / Loss of Charge and Freerstat Protection Switches - Copper Tube /Aluminum Fin Coils - Easy Access to all Electrical Components - Rigging Holes and Forklift Slots in Base Rails for Lifting - Single Point Power Connection - Powder Paint Finish That Meets ASTM7B117, 750 hr. Salt Spray Test Standards - Agency Approvals - UL & CGA on All Units - Factory Warranty - One Year on the Complete Unit - Four Additional Years on the Compressor - Four Additional Years on the Electric Heating Elements - Nine Additional Years on the Gas Fired Heat Exchanger ECONOMIZER w/ SINGLE INPUT ENTHALPY CONTROL ECONOMIZER w/ DUAL INPUT ENTHALPY CONTROL BELT DRIVE INDOOR FAN TechniCoat CONDENSER COIL OPTION T 2711? FACTORY INSTALLED OPTIONS REAR VIEW SIDE SUPPLY AND RETURN AIR DUCT OPENINGS 6.1 12 ' 4 Indicates a selected option or accessory UNITS WITH ECONOMIZER RAIN HOOD & FIXED OUTDOOR DAMPER HOOD ECONOMIW MIN 11000 REUE74 FIXED OUTDOOR AIR DAYPEA 11000 r A 10.u41 ialn -- 4 Date 06/12/96 Page 6 Order No ti 44111 L.N. END VIEW 7 ro 'so 9002 C E R I I i l E D Hole Opening Die. Use A .T/ Control Bottom 6 2" KO Power Side or Bottom C 3/4" NPTI Gas Piping Front 1/4 1-11t16 Hole Bottom r taL1L LIINU rCr I VINIvI/ilNL Total Capacity 123 MBH Sensible Capacity 89.0 MBH Efficiency (at ARI) 9.0 EER Part Load Efficiency 9.7 IPLV Outdoor DB Temp 95.0 F Entering DB Temp 80.0 F Entering WB Temp 67.0 F Leaving DB Temp 59.4 F Leaving WB Temp 57.3 F Power Input (w /o blower) 10.80 KW Elevation ''' 0 Ft HLAI INC3 PLKI Gas Fired Input @ Sea Level 204 MBH Gas Fired Output @ Sea Level 163 , MBH Steady State Efficiency 79.5 % SUPPLY AN t3LUWLK PLKFUKMANUE ' Total Supply Air 4000 CFM Outside Air 0 CFM External Static Pressure 0.60 IWG Duct Connection Location Bottom Blower Speed 932 RPM Motor Rating 2.0 HP Power Input Requirement 1.90 KW Brake Horsepower 2.04 BHP Power Supply 46U -3-t3U Total Unit Ampacity 27.6 Amps Maximum Overcurrent Device Fuse Size 35 Amps HACR Circuit Breaker 35 Amps Minimum Wire Size 8 AWG (75 C) • T • . : n Height 40 in Width 101 in Depth 71 in Total Weight (incl factory options) 1277 Lbs ULLAKANULS Front 24 in Back 36 in Bottom 1 0 in Top 72 in Left Side (filter access) 54 in Right Side (outdoor coil) 24 in JYORIC Heating and Alt Ca did:cling Job Name LENIHAN OFFICES Architect Engineer Purchaser SEGALE Submitted By APPLIED PRODUCTS QUANTITY: 1 UNITS DESIGNATION: Schedule flo: . Units may be installed on combustible floors made from wood or class A, B or C roof covering motorists. 2. Units must bo installed out doors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. SUNLINE 2000 TM GAS /ELECTRIC ROOFTOP UNIT (A) CONTNLt waUNO ----- ENTRY P cwen WANG • ENTRY RETURN AIR SUPPLY AIR CONDENSER AIR OUTDOOR AIR L./ (Economizer) A 1 In. clearance must be provided between any combustible material and the supply air ductwork for a Distance of 3 feet from the unit, SEGALE BUSINESS PARK, TUKWILA TUKWILA, WA. TUKWILA, WA. REtDCUPPUED (A) DISCONNECT SWITCH CCrRROL WIWNO LOCA'RCN \ ENTITY r yam (noo L'9 7r6 I 47.7,5 MO) ALMA ACCESS" 3+4' PVC FO.ULL \, COND. DRAIN CONN. _ p3« DeWI'V lec.aon 7, (e) POOCH wiped Moo D.t.ii •Y' b'xa'ani DO TOFA SUPPLY • AND OPDNNOJRh AW (SCE NOTE) 1 ' ocale the unit so that the vent hood outlet is at least: The products of combustion must 3 feet above any forced air inlet located within 10 horizontal feet not be allowed to accumulate (excluding those Integral to the unit). within a confined spew and • 4 feet below, 4 horizontal feet from, or 1 toot above any door or recirculate. gravity air Inlet to the building. Subject to change without notice - Check local code; • 4 feet from electric meters, gas meters, regulators and relief equipment. 7.14 Model No: D3CG120N16546EC KONEN ACCESS 7.1(4 62.12 Date 06/12/96 Pagel Order No VENT AVT OUTLET HOOD eaAPneseoa ACCESS ts.a O.Ibt - X') (Di -�• OAS SUPPLY ENTITY DETAIL ' X' 1510E SUPPLY AND RETURN Ain opshvrOS) Utilities Entry Date CON DCHSER COLL COYOUSTIDN AIR INLET NCOD FRONT VIEW UNIT BASE WITH RAIL$ Sham'eparaaly b Iluawau balorn du= Openings. ;vier Me gas p'sIng connection boedone. NOTE For cwb•,rowreed untie, Wet b the oust hanger denenebne of the ourt fa the proper sin el the cupply M! return air duct oonnecaons. JYORIC Healing and Air CondIdonkg - Complete Factory Package, Tested, Charged, Wired - Multiple Independent Refrigeration Circuits - Hermetically Sealed Compressors - Spark Ignition - induced Draft with Post Purge Logic on Gas Fired Units - Belt Drive Blower Motor - Standard - Bottom or Side Air Duct Configuration Capability - Low Voltage Relay Board With Terminal Strip - PTC Type Crankcase Heaters - Liquid Line Filter Driers - High & Low Pressure / Loss of Charge and Freerstat Protection Switches - 24 Volt Control Circuit with compressor lock out protection - Manufactured Under The Quality Standards of ISO 9002 - Permanently Lubricated Motors - Ambient Modified - Time/Temperature Defrost Logic on Heat Pumps •� ECONOMIZER w/ SINGLE INPUT ENTHALPY CONTROL ECONOMIZER w/ DUAL INPUT ENTHALPY CONTROL ECONOMIZER w/ SINGLE INP. E. C. & POWER EXHAUST ECONOMIZER w/ DUAL INPUT E. C. & POWER EXHAUST MOTORIZED OUTDOOR AIR DAMPER ANTI - RECYCLE TIMER MOTORIZED OUTDOOR AIR DAMPER 0 Deg.LOW AMBIENT CONTROLS ECONOMIZER w/ SINGLE INPUT ENTHALPY ECONOMIZER w/ DUAL INPUT ENTHALPY CONTROL FIXED OUTDOOR MR OR ECONOMIZER BAROMETRIC RELIEF RAIN 11000 RAIN 11000 11161 ' IIi�Mti�� .� Indicates selected option or accessory REAR VIEW I .Fs eqce pl P ik # SUNLINE 2000TM GAS /ELECTRIC ROOFTOP UNIT D3CG120N16546EC .i; GENERAL FEATURES FACTORY INSTALLED OPTIONS Refer to PRODUCT DATA on front side for electrical data. FIELD INSTALLED ACCESSORIES THERMOSTAT - 0 -25% Fixed Air Damper with Hood - Standard - Copper Tube /Aluminum Fin Coils - Easy Access to all Electrical Components - Rigging Holes and Forklift Slots in Base Rails for Lifting - Single Point Power Connection - Powder Paint Finish That Meets ASTM -B117 750 hr. Salt Spray Test Standards - Accu -Sense Changeover Control for Maximun Heating Comfort between Gas & Heat Pump Operation on Dual Fuel Units - Agency Approvals - UL & CGA on All Units - Factory Warranty - One Year on the Complete Unit - Four Additional Years on the Compressors - Four Additional Years on the Electric Heating Elements - Nine Additional Years on the Gas Fired Heat Exchanger TechniCoat CONDENSER COIL OPTION ALTERNATE BLOWER MOTOR BAROMETRIC RELIEF DAMPER 4 ROOF CURB BURGLAR BARS PROPANE CONVERSION KIT LOW NOx KIT HIGH ALTITUDE NATURAL GAS HIGH ALTITUDE PROPANE GAS PIPING KIT UNITS WITH ECONOMIZER & FIXED OUTDOOR AIR HOOD , • 2P 3414• ECONOMIZER RAW 11000 20 3M• CONDENSATE DRAW (1 ual M tripped) Date 06/12/96 Page 8 Order No - 71• L.H. END VIEW (B) rowan WIRING ENTRY :\ h_ 29 3.12• 'so PPP.? 412• YORK Hoeing aryl #k Concitioning -•• 1 ": 11 • . . • . D6CGO6ON07946EC, D6CG048N06046EC, 37.114" DUCT SIZES: Supply Air • 19.1/4" X 19 -1/4" Return Air 19 -114" X 19-1/4" FRONT VIEW (3 -JOIST SUPPORT) RETURN' AIR BACK OF UNIT SUPPLY* AIR DUCT SUPPORT. RAILS NOTE: Both supply and return air duct openings are square and the same size, providing easy duct installation. Ducts can be installed onto the curb from the roof. All electrical wiring connections can be made Inside the curb. 3/4" X 1.1/4" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES SUNLINE 2000TM 3 Thru 6 Ton Roof Curb Details Job Name: LENIHAN OFFICES UNIT BASE- WOOD NAILER• — 14" 8" MIN. ABOVE FINISHED ROOF — CURB FRAME— INSULATION' " 2" TYP. • Subject to change without notice • Check local codes 4• ROOF DECK AND SUPPORT STRUCTURE Date 06/12/96 Page 9 Order No COMPRESSOR AND CONDENSER END OF UNIT FRONT 73" OF UNIT 'Supply and Return Air (including duct support rails) shown are typical for bottom duct applications. For location of horizontal duct applications (on back of unit), refer to Unit Dimension details. FRONT VIEW (2 -JOIST SUPPORT) %F R,. ryas —►�—,• n Tho 43.1/2" overall duct dimension allows ductwork penetration between roof joists that are spaced on 48" centers. UNIT BASE RAILS COUNTERFLASHING CANT STRIP INSULATION AND ROOFING MATERIAL JYORIC Hoeing and Alr Cotddo ,ing 2" TYI'. ,. .` •• . \�24" 63-1/4" >'" � ROOF CURB DhTAILS FORTHE FOLLOWING: D3CG120N16546EC, ..u,ra.r•r,:':'...:s;•rrcr�.: r..+ x.,- rrm. ��..: n.7 ?nt, rrr.. nl..'. t.rrw'r�• «ma• SUNLINE 2000TM s ' 7.5 Thru 12.5 Ton Roof Curb Details Date 06/12/96 Page 10 Job Name: LENIHAN OFFICES Order No MIN. ROOF OPENING: DUCT SIZES: 28" Wide X 45" Long Supply Air . 16" X 23 -3/4" BACK SUPPLW ` . Return Ak • 20-1/2" X 23 -3f4" OF UNIT AIR RETURN DUCT AIR" SUPPORT RAILS 24 40 1/2'p --- 96' 1 The 4" space between tho ducts allows for 'lumping" an existing roof joist 2 The 41 "ovorall dimension of tho ducts allows ductwork ponotratlon between roof lolsts that aro spaced on 48" centers NOTE: Duds can bo Installed onto tho curbfrom tho roof. All electrical and gas line connectoctions can be mado Inside tho curb. 3/4" X 1.1/4" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE- L W000 NAILER -- 14" 9" MIN. ABOVE FINISHED ROOF — CURB FRAME— INSULATION' FRONT OF UNIT FRONT VIEW (JOIST SUPPORTS) 93" Subject to change without notice • Check local codes 93" DUCT 7-1 2" SUPPORT RAILS I INSULATED DECK ON OUTDOOR COIL �.� END OF UNIT • UNIT BASE RAILS COUNTERFLASHING CANT STRIP INSULATION AND ROOFING MATERIAL - r ROOF DECK AND SUPPORT STRUCTURE r:ru-: ••.arve «�.=wck: <ro�r.�+rx:r� 000 OOO 000 A nders wn - Peyton Structural Engineering Consultants g g A Division ofACP Consultants, Inc 31620 23rd Ave. South, Suite 321 F edual Way, WA 91003 Phone: (206) 941.9929 Fax: (206) 941.9939 MemoPad ?,:t from Brian A. Dickson 0 Memo 0 C n Log 0 Confi. 0 Info: Page 1 o , I , Distribution Date: 4/23/96 Time: 10:00 a.m. Steve Nelson Project: Segale Business Park Mechanical Units Project No. 96108 Dean Peyton Person: Steve Nelson Phone No. 575 -2000 Company: Segale Business Park Fax No. 575 -1837 Subject: Existing Framing to Support Mechanical Equipment Sent Via Fax 0 Mail 0 Billing File 0 Steve - As requested, we have performed a structural review of the existing roof framing on the subject building to verify that the framing will be adequate to support the new mechanical units as indicated on the enclosed mechanical / framing plan. Please note the following: • The following York Mechanical units shall be installed: Unit 105 Unit 3 Unit 2 • Units 1,3, and 5 shall replace the existing units which are currently installed at the subject plan locations. The unit shall be installed with the middle 1 /3rd of the unit placed over the existing glulam beam framing. The ends of the unit which are parallel to the glulam beam shall be supported by 2x12 #2 Hem Fir joists spanning between the typical 4x purlins which are installed at 8' -0" o.c. See enclosed framing layout. • Units 2 and 4 shall be installed similar to as described above. These units shall be located a maximum of 14' from the beam supports either in an existing unit location or in a new location. • All units shall be installed per the manufacturer's guidelines and per standard methods and materials. If we may be of any further assistance or if you have any questions, please feel free to contact us. Respectfully Submitted, Anderson - Peyton Structural Engineering Consultants Brian A. Dickson Design Engineer Enclosure: (None) C"RI614) UN C:tD W ORKICRSPNDNc1ZM1 SC\9610sM01. DOC York Model D6CGO60N * ** (Installed Weight = 900 pounds maximum) York Model D6CG048N * ** (Installed Weight = 875 pounds maximum) York Model D3CGI20N * ** (Installed Weight = 1450 pounds maximum) I .ter -c is ,'- - /S NOT 13i■G 07/74 CITY APPROVED AP JUN 241996 EXPIRE. 4/ 1G/ dp 7 DING DIVISION RECEIVED CITY OF .TUKWILA JUN 1 7 1996 PERMIT CENTER 0187/961:22 PM OOOAndersor(. Peyton J OEj Structural Engineering Consultants OOO Division of ACPConsulianta, Inc. PROJECT lv 4-x 00 t2- LWt.%.. t'L.+S4%.1 .�''. s'-o" .0. 2x t0 • t3 • • xT(r ( -4.)t-44 ( % L SO' t`-e&A Sc i . i _ • 1.. Le■-\C.- , cat.... • • t—.)N.1 t i JOB # SHEET OF. DESIGNED DATE CHECKED DATE t�X TC. LAX-4J 1, 1 t•"t...�L I.t' • ••, • i • t-� ; iZx ►Z t.:44 IT .. w �.._t_taszt� N. tcr�Z i t l...)Z.utc • ' .1_ ' %3tt0 • . Lir • • • • 14■7 ' E Co4cr ` ) It 'fttr'„ 31620 23rd Avenue South, Suite 321 Federal Way, WA 98003 (206) 941 -9929 Fax: (206) 941.9939 Seattle / Eastside (206) 292.0940 Z RK° INSTALLATION INSTRUCTION •�-� • t��r.: ��_ - GENERAL YORK Model DCG units are single package air conditioners with gas heat designed for outdoor installation on a rooftop or a slab. The units are completely assembled on rigid, permanently attached base rails. All piping, refrigerant charge, and electrical wiring Is factory installed and tested. The units require only electric power and duct connections at the point of installation. The gas -fired heaters have aluminized steel tubular heat exchangers and spark ignition with proven pilot. FOR YOUR SAFETY if you smell gas: 1. Open windows. 2. Don't touch electrical switches 3. Extinguish any open flame. 4. immediately call your gas supplier. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. INSPECTION As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. Refer to Form 50.15 - for additional information. REFERENCE U Additional information on the design, installation, operation and service of this equipment is available in the following reference forms: SUNLINE 2000TM GAF ' ELECTRIC SINGLE PACKA•..IE AIR CONDITIONERS Supersedes: 530.18 -N 10Y (693) MODELS D3CG090, 102, 120 (STYLE B) & D4CG150 (STYLE A) (8.5 -9.0 EER) 'so 9002 CERTIFIED • 55.70-N1 • 55.70 -N2 • 530.18 -N3.2V - • 530.18 -N3.4V - • 530.18 -N8.4V • 530.18- N10.1V • 530.18- N10.2V • 530.18- N10.3V • 530.18- N10.4V • 690.15 -N25V - Renewal Parts: 530.18 -N10Y (995) 035 -13092 ,q 1 7 g e g CC , 208230 VOLT MOOELS ONLY General Installation Pre -start & Post -start Check List Economizer Accessory Motorized Outdoor Air Damper Accy. - Gas Piping Accessory - Propane Conversion Accessory (USA) - High Altitude Accessory (Nat. Gas) - High Altitude Accessory (Propane) - Propane Conversion Accessory (CAN.) Low Ambient Accessory • Refer to the Renewal Parts Manual for complete listing of replacement parts on this equipment. All forms referenced in this instruction mcy be ordered from: Publications DIstrIbudon Center Unitary Products Group P.O. Box 1592, York, Pa. 17405 APPROVALS Design certified by U.L & CGA as follows: • 1. For use as a forced air furnace with cooling unit. 2. For outdoor installation only. 3. For installation on combustible material. 4. For use with natural gas or propane gas. CAUTION THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED T0, BUILDING, ELECTRICAL,AND MECHANICAL CODES. WARNING INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE. Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. t11ZtSS are intended to clarity or make the installation easier. Cautions are given to prevent equipment damage. Waminga are given to alert installer that personal injury and/or equipment damage may result if installation procedure is not handled properly. CONTROL CURVC COHT MINT (A /M0N.DCGJ AT 00A RH A 13 11/1 0 10 1 C N (111 o 03 1 MODEL DCG 090 I 102 I 120 150 EVA PORATOR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. in.) 12 x 12 12 x 12 15 X 12 15 x 12 FAN MOTOR HP (STANDARD) 2 2 2 3 FAN MOTOR HP (ALTERNATE) - I 3 3 5 EVAPORATOR COIL ROWS DEEP 4 I 4 4 4 FINS PER INCH 15 I 15 15 15 FACE AREA (Sq. FL) 7.8 I 9.1 10.9 13.4 OUTDOOR FAN R»o Per unit) PROPELLER DIA. (In.) 24 ea. I 24 ea. 24 oa. 24 oa. FAN MOTOR HP 1/2 ea. I 12 ea. 1/2 oa. 3/4 ea. NOM. CFM TOTAL 2900 ea. l 3200 ea. 3600 ea. 4400 ea. CONDENSER COIL ROWS DEEP 2 2 2 2 FINS PER INCH 13 13 13 13 FACE AREA (Sq. FL) 16.7 I 20.0 24.0 29.3 AIR FILTERS (SEE QUANTITY PER UNIT (12' X 24' X 2) 2 I 2 • - QUANTITY PER UNIT (16 X 24" X 2") 2 1 2 2 3 QUANTITY PER UNIT (18" X 24' X 2 ") - I 2 2 TOTAL FACE AREA sq. it.) 9.3 I 9.3 11.3 14.0 CHARGE REFRIGERANT 22 (Ibsioz.) SYSTEM NO. 1 6/8 I 7/4 8/0 10/4 SYSTEM NO. 2 6/8 I 7/11 8/12 10/8 8 530.1 8 -N t OY TABLE 4 - PHYSICAL DATA NOTE: Filter racks ars adapted for I • or 2' puck Alters. FIG. 9 - ENTHALPY SETPOINT ADJUSTMENT IS 10 00 100 100 110 11.11 tul 1)11 1111 1 III is II w 40 10 II 00 11 10 10 00 II 00 00 100 101 1141 10AI In 1101 1111 II .11 11111 III) 11 1 IaAI 1 1111 lul 110.11 ORV /UL/ T(101(RATURC (AMROXIMATC►- fAHRCHHCIT ICCLS 1.711 7.1/2 Ton 8 -1/2 Ton 10 Ton 12.1/2 Ton _ 1220 BASIC UNIT A Economizer Motorized Outdoor Air Dam.er WEIGHTS (LBS) RI S 1100 125 1 4713 Roof Mountin. Curb 77 75 Unitary Products Group J c� 0 V u UTILITIES ENTRY DATA HOLE OPENING SIZE (DIA,) USED FOR A 3/ KO Control Wiring Side 7/8' KO Bottom' B 2' KO Power Wiring (Side or Bott om)' C 2' KO Gas Piping (Front) D 1- 11/16 KO Gas Piping (Bottom)• Front 24' Back 12' (Loss Economizer) 36" (With Economizer) Lett Side (Filter Access) 24' (Less Economizer) 54' (With Economizer) Right Side (Cond. Coil) 24" Below Unit' 0" Above Unit 72" with 36' maximum Horizontal Overhang (For Condenser Air Discharge) 33.7,' 10°° 30313 ( 47.713 ( ALTER ACCESS ' EIDWpRJEO (A) ss.av[R ocortiecr ewTTCN Correct O AOCW r " LOCATION UMW Ye PVC reIALE Mill ()PAN 00..r. (e•. o.w •Y• b wow t (O rows wrwo DORY (4. D.I.+ •Y• for Wsen) ao •Ttu wrrtY ANO nCTLIM Aut (SE! NOTE) GAS /ELEC UNITS (A) COiTertlettereaa ENTRY (0) PC O1R WIrW G DOTY 3•w DUCT COVERS - Units are shipped with all air duct openings covered. For adr3 duct applications; 1. Remove and discard the supply and return air duct covers. 2. Connect ductwork to duct flanges on the mar of the unit. For )291tom duct applications; 1. Remove the side supply and return air duct covers to gain access to the bottom supply and return air duct covers. 2. Remove and discard the bottom duct covers. 3. Replace the side duct covers. Unitary Products Group OJTt cco ACC a e[q Acca (Y. Owl •X•) OAS MGT .cccv (C) 6U wpm ENTRY O OAS TUKLY EMRY UNIT BASE WITH RAILS enc.o e.orerly I. Ouse ma sonom duct ouaninge, Power and am piping cathedral loc•uone. NOTE: Fa curtrma.m Yd WITS. Islet lo M duct h.ngo dIrnonslma ma 010 Ice he proper She at h• eupp)y and r.IUnl Se duct 0atnectkAs. gUTDCOR AIR HOCC EVAPC*LLTai CCII. REAR VIEW CONDENSER Cole. Cwx/■r+CN MI INLET MOOD Dy4 FRONT VIEW FIG. 10 - DIMENSIONS & CLEARANCES- 7 -1/2 - 12 -1/2 TON [I> RETURN AIR SUPPLY AIR CONDENSER AIR - l % ) OUTDOOR AIR L__,/ (Economizer) 530.18 -N10Y All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. 'Cowlings In he bottom of he unit can be located by the silos In M Insulation. DETAIL 'Y' purr WITH ECCNCMZER MIN HOOD) 6 ' 1 M ' Locate unit so that the vent air outlet rood Is at lease • Throe (3) feet above any lorcod air inlet located within 10 horizontal feel (e.clwtng those intogral to he unit). 2dI5 • Four (4) feat below, 4 horizontal feel horn, or I tool above any door or gravity air Inlet Into the buikIng. • Four (4) feel from e)ecuic meters. gas meters, regulators and retlef ecuipmenL Units (applicable In U.S.A. only) may be installed on combustible Soon made horn wood or Bass A. B or C root covering material. 3 Units must be Installed outdoors. overhanging structures or siuubs should not obstruct the condenser air discharge outlet. NOTE: A 1 • clearance must be provided between any combusebte malertel and the supply *Jr ductwodl for a dstance o13 feet ham he i nt The produce of combuston must not be allowed IS accumulate within a moaned space and recirculate. 9 6 C G o w i cx DESCRIPTION YORK Sunline 2000 units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for residential, light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self- contained and assembled on rigid full perimeter base rails with fork lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to provide for a quick and easy field installation. The units are available in cooling only, and cooling with gas heat. Electric heaters are available as field - installed accessories. FEATURES ✓ 6 C , . • S Q • • r , 530.18 -TG I Y (295) DCG MODEL SHOWN The cabinet is constructed of galvanized steel, painted with long lasting, durable, and aesthetically pleasing power paint. Paint finish meets 750 hour salt spray tests per ASTM -B117 standards. All models include a 5 -year limited warranty on compressors and electric heating elements, a 10 -year limited warranty on gas -fired heat exchangers and a 1 -year limited warranty on all replacement parts. COMMON FOOTPRINT /COMMON CABINET - All model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. He can even decide between gas or electric heat after the curb has been set. HIGH EFFICIENCY - All units have a high cooling efficiency, and gas / electric models have a minimum AFUE of 80 %. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side SINGLE PACKAGE AIR - COOLED AIR CONDITIONERS D3CE 036, 048, 060 & DICE 072 D6C.G 036, 048, 060 & D1 CG 072 4" AND 5 tsitiMINAL TONS (10 SEER) AND 6 NOMINAL TONS (9 EER) SUNLINE 2000TM Km duct covers from the outside of the unit and discard them. If a bottom supply / bottom return is desired, you simply remove the two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required) Convertible airflow design allows maximum field flexibility and minimum inventory. Economizers may be used on either bottom and side duct applications with no modifications required. FACTORY - INSTALLED OPTIONS - Economizers can be installed at the factory. The economizers are shipped installed and wired. Only the rain hood needs to be field assembled and Installed. Field labor dollars can be saved by having the components arrive already installed. Adjustable belt drive blowers are available on most models from the factory for complete airflow flexibility. FIELD - INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided in the internal partitions to connect the elements to the control box single point kit. The 14' high roof curb is shipped knocked down. An insulated deck is not required because the bottom of the unit is insulated. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0 °F. Propane, high altitude and low NOx kits are also available to cover all gas heating applications. WIDE RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5 -ton models operate over a wide range of design conditions with a 3 -speed direct-drive fan motor. The 6 -ton unit has a single speed direct -drive fan motor. Belt -drive blowers are also available on all 3, 4 and 5 -ton models and on 6 ton, 3 -phase models. FULL PERIMETER BASE RAILS - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. Cont'd. MODEL ARI RATINGS' NOMINAL ELECTRIC HEAT CAPACITY (KW) COOLING CAPACITY 80 / 67 -95 °F SOUND RATING (bets) MBH SEER EER 240V 480V 600V DCEO36 40 10.10 ;.9.30.> 8.6 5 7, 10, 15320 7, 10, 15620 10, 15620 DCE048 48 10.35 t9.45.; `: 8.6 5, 7, 10, 15 6 20 7, 10, 15 b 20 10, 15 &20 DCEO60 59 10.15 i,;'y;�! ...,; ; ;• „ °;. 8.6 5 7, 10, 15,20 &30 7, 10, 15 20 & 30 10, 15, 20 &30 DCE072 72 40-70 9.00 8,4 5, 7, 10, 15.20 & 30 7, 10, 15, 20 & 30 10, 15, 20 & 30 MODEL ARI RATINGS I GAS HEAT CAPACITY COOLING CAPACITY 80 / 67 -95 °F SOUND RATING (bets) INPUT (MBH) OUTPUT (MBH) AFUE (%) S.S.E. (%) S.E. (/e) TEMP. RISE (eFl GAS UNE SIZE (In. OD) MBH SEER EER DCG036N040 40 10.10 ;'.,9.30':x. 8.6 50 40 80.9 81.6 75.9 15-45 1/2 DCG036N079 40 10.10 '= 9.30'' k 8.6 100 79 80.5 80.8 73.6 40-70 1/2 DCG048N060 48 10.35 . ;;,9:45 8.6 75 60 80.9 81.6 77.3 25-55 1/2 DCG048N099 48 10.35 ! ; 8.6 125 99 80.3 80.6 77.9 45-75 1/2 DCGO60N079 59 10.15 ;`..9.40-'`. 8.6 100 79 80.5 80.8 73.6 25-55 1/2 DCGO6ON099 59 10.15 •`9.40 8.6 125 99 80.3 80.6 77.9 35-65 1/2 DCG072N079 72 - 9.00 8.4 100 79 80.5 80.8 73.6 25-55 1/2 0CG072N099 72 - 9.00 8,4 125 99 80,3 80.6 77.9 35-65 1/2 MODELS DCE/DCG 036 046 060 072 _•_, EVAPORATOR BLOWER CENTRIFUGAL BLOWER (Dla. x Wd. In.) FA N MOTOR HP (BELT-DRIVE) E) 12 x 10 1 1 12 x 10 1.5 12 x 10 1.5 12 x 11 1 1.5 EVAPORATOR COIL ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) 3 13 3.6 3 13 4.3 3 13 5.1 4 13 5.1 COND SER PROPELLER DIA. (In.) FAN MOTOR HP NOM. CFM TOTAL 22 1/2 4.500 22 1/2 4.200 22 1/2 4.500 24 1/2 4.500 CONDENSER COIL FINS PER PER FACE AREA (Sa. Ft.) 16 17.1 19 17.1 22 17.1 16 16.7 AIR FILTERS (SEE NOTE) QUANTITY PER UNIT 14' X 20' X 1' QUANTITY PER UNIT (14' X 25' X 1') TOTAL FACE AREA (sq. ft.) 2 1 • 6.3 2 1 6.3 2 1 6.3 2 1 6.3 CHARGE REFRIGERANT 22 /lhs oz 1 /Q 6/5 7/4 1d9 • RATINGS CAPACITY RATINGS - Cooling / Electric Heatin u CAPACITY RATINGS - Cooling / Gas Heating I Reings an in kro,dane. 14th ARV Standard 210. Sound ratings an in accordance with ARI Standard 270. 3 1-eaters are available as accessories • al etch sirtsits point power supply. SEER • Sea+a 1 EneW Efficiency Rein • M low( coo'ri output h 6TVs dxhg a normal anal usage pealed ter owing candied by the tan *con power input in wlfian dretg tits sone period EER • Energy Efficiency Ratio • the cooling capacity In Bib per hour ((huh) dvlded by the power input In watts at any silvan set of rating candtlons, expressed In BTUN per watt (BTUWwett). AFUE • Annual Fuel Utilization Efficiency • deteminecl In accordance with DOH test procedrre. S.S.E. • Shady State Efficiency. (Portent Output). S.E. • Calbnia Seasonal E16dan y • delerrnhed In *xo dears wilt bat protection as specified by the Saw of Calbmfa Energy Commission Furnace* an av■t Ul wok a tow NO* awasoay. d" :N�,r, t • Not ARI Usted l Krk >h9, PHYSICAL DATA - Basic UNITS NOTE: Fitter racks an adapted for 1 • or 2• thick Nten. COMPONENT WEIGHTS TON 79 Mbh _615 99 Mbh • TnA' 1 1,4 - rtZO 655 880 6 Tf?N 7.95 735 Basic Unit Unitary Products Group COMPONENT DCE (poling only) DCG (Gas / Electric) Economizer Relleltaxed Damoer B elt•nrive Blower NOTE: Weights an Oven in pounds 40 Mbh, 60 Mbh Motorized Outdoor Air D tmper 5 7 KW 545 605 TO ELS CE & SO 48 18 0 dons Electric Heat and Nominal KW) Accessories Roa Mou Curb 2Q_-_30 KW 92 1.0 S 530.18 -TG1Y 670 3 ROOF CURB DIMENSIONS - (DOE and DCG -3,4,5 & 6 TON) ROOF CURB BENEFTTS 19-1/2' 37-1/4" DUCT SIZES: Supply Air 19-114" X 19-1/4" Return . 19-1/4" X 19-1/4' NOTE: Both 'ivory sir and Mum air duct comings are square and an• the same size, pro. *kg saw dirt instagation. Ouch cart be Metaled onto the curb from the root. M Wctrical airing connections can be made Inside the curb. UNIT AND CURB APPUCATION Unitary Products Group RETURN' MR BACK OF UNIT SUPPLY' MR FRONT VIEW (3-JOIST SUPPORT) 314' X I-1/4' WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE WOOD NAILER 14' B' MIN. ABOVE FINISHED ROOF — CURB FRAME— INSULATION DUCT SUPPORT RAILS 2' Typ.-->, CroaPRE=R AND CONDENSER END OF UNIT FRONT OF UNIT 'Supply and Return Air (Including duct support ralls) shown we typical for 12Qt tIlm duct spc4lcatIons. For location ol horlinntit duct applIcatIons (on back of unit), relit to link Dimension details. • FRONT VIEW (2-JOIST SUPPORT) The 43 wrong act &mansion glows the:molt penetration Whew roof most* are cooed on W meas. UNIT BASE RAILS COUNTERFLASHING CANT STRIP INSULATION AND ROOFING MATERIAL ROOF DECK AND SUPPORT STRUCTURE - I 530.18-TG1Y 19 OOOAnders'"'on - Peyton M Structural Engineering Consultants 00 0 A Division of ACP Consultants. Inc. PROJECT 5 t &- 31620 23rd Avenue South, Suite 321 Federal Way, WA QR001 t1ful n41 ^^ JOB II SHEET OF DESIGNED DATE CHECKED DATE 1'L l2C0t L ex r l..(r 12Lts s= • ■`'t:e- Cr4+ .. `00 :fit C J . ;. ... _ ( 6 • `'*..:. -4."� ......:_.� w . :._:. , u�.AlcyEtL,. ' • ,A5Ntr. 1� r • • ; 1 1 1 ••••.• ... • • ... 3 ,. • • , .....1. • �-.= . lots". # �! , c K_, • . 3 a .,..., , ....,. t • • ZktO. ` •Z; tli` ., ot , ESC =;� Go; • , (CC,iZ -: 4s"0 +' ...: -� t,s�! (04)C`cas=) OOOAndersoC - Peyton MO Structural Engineering Consultants OOO Division of ACP Consultants. Inc. PROJECT JOB # SHEET OF DESIGNED DATE CHECKED DATE Ul‘k c "2 ( Oht C-Zt tJ . cam � .. :? .. z" e_ Z. • t ,� t / ���✓�J. . c L-�3 , i i t , ' • • ;..,. i ; • 1)LaLL— (z 1 z<i)(Z ri;a Belo V,i '; 7-.7/,4t� U1 - 2 zNS • tetV gL - Z7 - eafC* (1,1J , L�•75�� 2 ��.� - ` -7,,h7 C,z)/t_c. ) .L / � )C � � �-) z • .Aso zz 31620 23rd Avenue South. Suite 321 Federal Way, WA 98003 (206) 941.9929 Fax: (206) 941.9939 Seattle / Eastside (206) 292-0940 k ` OOOAndersoC'.- Peyton (71Q(J Structural Engineering Consultants 000 A Division of ACP Consultants, Inc. PROJECT A... ..- . ..,...._._...x..,.0..._..4.03.. •••n•1...••*.•• .......a,...,,,..,, 31620 23rd Avenue South, Suite 321 Federal Way, WA 98003 (206) 941.9929 Fax: (206) 941-9939 Seattle / Eastside (206) 292 -0940 JOB # SHEET OF DESIGNED DATE CHECKED DATE ■ I , vc`. i ... i _.. .. • 1. . ' �dC.TtOwl +' i 6,0 :. - .. t`+ i-cj • t't (. ' ; _0 0 104.(C. t _ _ t °l0 - •I i -+- • She? - � ✓ C7�. • c' ,4,4 t. ' •: .: �.. / - ' t / , - _ : . :1X-:1 0, • . 0 , 0 0 0 .: - , .;• i...; .,- 1...,. - .._- .: ...i EG.t+.... 4 - i l., . ..._; !. ,.., ,..1..�_, _; ..� ...( .; :. . f :. 0;000 • mow + ! _ (._. f • t i _ .;. ` ' I • f 1 ...1._. i i ! -!. ,..., ! _l.. 1 r t l r . . _... �... .. . +. - . I - • .1 , . t.! . I • 1 , t , • 1Z Jan 31, 1997 98032 MIKE DONOHEW 801 NORTH CENTRAL KENT, WA RE: LENIHAN DISTRIBUTING CO. Dear Permit Holder: City of Tukwila Sincerely, 1 /a Kelcie J. Peterson Permit Coordinator Department of Community Development FILE COPY John W. Rants, Mayor Department of Community Development Steve Lancaster, Director Our records indicate that on Dec 22, 1996 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechanical Permit Number' �M96- 0074. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Dec 22, 1996. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670. • Fax (206) 4313665 Dear Sir: Fire Department Review Control #M96 -0074 (512) .. w... r��vu. e��wawa .wral�w+wwvtYY�ru�.�.�Mwr City of Tukwila la John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief ._tune 21, 1996 Re: Lenihan Distributing Company - 18200 Segale Park Drive B The attached set of b u i l d i n g plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: tlr�MPeY e+ 1. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall he accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall he installed in accordance with the manufacturer's installation instructions. (UMC 608) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) 2. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) .57$4404 • Fax (206) .575-4439 Page number Yours truly, cc: City of Tukwila Fire Department until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have' job site address, name and the Tukwila Fire,. Department Job Number available to confirm shut down approval. (City Ordinance #1742) 3. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition. and /or violation of the adopted Fire or Building Codes does not imply approval of such or violation. • The Tukwila Fire Preve ion Bureau TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 S Phone: (206) 575•4404 • Fax (206) 575-4439 CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 06/19/96 Activity document routing maintenance. MECHANICAL PERMIT Permit No: M96 -0074 Tenant: LENIHAN DISTRIBUTING CO. Status:. PENDING Address: 18200 SEGALE PARK DR B Route: .1 Current Route Line: 2 of 5 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaadaaaaadaaaaaaadaaaaaaaaaaadaaaaaaaaaadaaaaaaaaadaaddaaadaaaadaaada Packet Units Action Station Initials 'Status Received Assigned Completed MECH 0101 C BLDG KEN Ap Cond. 06/17/96 06/19/96 06/19/96 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): •Overtime Hours(HH.MM): Comments 1[H.V.A.C. OVER 2;000 CFM REQUIRES AUTO SHUTT-OFF. ] 2[ ] 3[FIRE PLEASE REVIEW AND COMMENT..'. by KEN ] 4[ ] 51 61 71 ] 81 9[ ] 101 l F1 =Help; ESC =Exit current screen. • 1.1.Yarnid.61.11.1011...V4 , —• • Ant.u. • , DEPARTMENT OF LABOR AND INDUSTRIES: THIS CERTIFIES THAT THE PERSON NAMED HEREON ,IS REGISTERED AS PROVIDED BY LAW AS A 4' i j. 4•''S ,, ,—;;.1' i IA d .' Cc! - 15 f‘ri Lc -rir ='„ LI t-V.C.P • . e ERMEMEMTMMBEFE 7g; isfM 20, 5 1 arr.....47 .,.,-.. 4 '... '1.1 -a .- 11 -47, STATE OF WASHINGTON A do „ vt. .•'.itti.,;•de ''' ir- , '44=-1P4rxr*tirN, **Mt. tropry.,.4.0 • ex .1 F625.052.000 (3.92J leZZ=1.64.a..*J. v• • St!.I.Y•tir.,+••.• _ . t- DETACH TO DISPLAY CERTIFICATE • & /17 A?4. ,,.eeL • •) • ;•'\ ; •0 • RECEIVED CITY OF TUKWILA JUN 1 7.1996 PERMIT CENTER SCOPE OF WORK I Replace existing 5 ton pas /electric unit with a new York 5 ton gas/electric unit. 2 Replace existing 7 -1!2 ton heat pump unit with a new York 10 ton gas /electric unit 3 Replace existing 4 ton gas /electric unit with a new York 4 Ion gas/electric unit. 4 Replace existing 5 ton pas /electric unit with a new York 5 ton gas /electric unit. General Notes. • licmnve existing units and curbs • Refrigeration recovery of old units as required • 1.0y out new curbs to match existing supply and return duel to existing ductwork • New curbs to be leveled and suructural modifications to the building for new curbs as required • Roofing and roof insulation at new curbs as required. • Ductwork with I" insulation as required to connect to existing ductwork. • Disconnect electrical power to each unit. Supply new disconnects and 110 volt service as required. • Disconnect gas piping to each unit. Re- connect gas piping and install new piping to unit 112. EQUIPMENT SCHEDULE SI - "YORK" Packaged Roof Top gas/electric. HVAC Unit. Model D6CGO6ON09946EC, nomial 5 ton capacity, 10.1 EER, 63.0 MBH Total Capacity, 100 MBH Heating Capacity, 80.5 % AFUE, Factory roof curb, Economizer. 2000 CFM (7n 0 43 E.S.P., I H . Motor, 460 volt / 3 Phase / 60. #2 "YORK" Package Roof Top gas/electric HVAC Unit. Model D3CG120N16546EC, nominal 10 ton capacity, 9.0 EER, 123 MBII '.. Total Capacity 204 MBH Heating Capacity, 79.5 % AFUE, Factory roof curb, !Economizer 4000,CFM@ 0.60 E.S P 2 H.P. Motor, 460 volt / Phase /60 #3 "YORK" Packaged Roof Top gas/electric HVAC Unit. Model D6CG048N06046EC! nominal 4 ton capacity,. 10.3 EER, 51,0 MBH 'total Capacity, 75 MBH Heatin capacity: 80.9 % AFUE, Factory roof curb, Economizer. 1600 CFM (r) 0,54 E.S.P., 3/4 H P. Motor, 460 volt / 3 Phase / 60 #4 SAME AS Ill M '1` , N VAC • 6,0N4ro6 4o covpl( wi+ W S.E.c. Sec4"io% 14 t 9 the P109 dress pppres,ale PSA: under�ta 4 P py91 of trlaotl0 eevr estop dose ddfsePrhdmen.�� l i9socknoy o l co e geF!• ,tea ya p Ie g agtor SCOPY °�epProvebp l- ENII - tAN oars: Gn9G . 9G. APPROVICI3 BY aeaws Be A,yrj PLVIMILP a 200 2 /+n IT, DRAWING MUMMA mqVo - 0014 LEGAL 0E5CRIPTION \ 1 . V1.41 Eq VALVE EATEN LINE E MT. IN -A I./ FAVOR KMG CO /r - L VAULT ° •13 °D ' 0 ' OOH - 1 - RR. SPUR TRACK = 47 aa33 7` \ \\ \\ \y L = p833 . ZrAge C IC COVERS 47pg , CeC.�VAULTG�iI R Tra70WLV� • COVERED j1 CB'- -Ca SOUTHEASTERLY \\ LDG. LINE \\s 07°4W FAVOR OF KING CO. W.G. I; 75 \\ CB e"S®I IS" OAS N 07 °4624 E C rvia ER C R B A O 434'74 \ RO \\\�Ck \ \ \ \ \ \\ \\V (‘KM R PM , NORTHWESTERLY BLDG LINE CONCRETE OFFICE WAREHOUSE 20 ESMT. IN FAVOR OF CHICAGO MILWAUKEE) De11°40' 00 ST PAUL AND PACIFIC RR, UNION PACIFIC 9,0 ;, AND OREGON AND WASHINGTON R.R. AND NAVIGATION CO. R = 477,47' AUO. FILE NO. 7 70 70 500 75 • e - , n •� \• --537.3 END W ATER ES T. \ \\\\\\ \\ \\\\\\\\�\\TI FIRE HYDE. W.VE 1' /2" PVC' TYPICAL WATER SERVICE N 07. °4624E 101.05 N B2°I24300 36 W \ \ \ \ \ \ ' A.R. LEAD 'TRACK S 117.5, i' NTEL TER METER S7(V RE 31111: ONISIn" \ \\ ONTET ROL / \\I \\ AL \ \�\ \ /S6 \\\\ \ \\ . N07 °4fi2 E \ \O 24.00` S 82 13.36E , L \ \\\\ 6.13° 06' 17" _ R =1134.55 M.H. J' =259 -50 - - - - - -- ' PARCEL NO.' 1 That portion of the Southwest Quarter of the: Northeast Quarter and Government Lot 5 ALL in Section 35, Township 23 North Range 4 East, W.M., in King County, Washington, described s- follows: • IIF BEGINNING at a monument at the Northeast cbrner of the said Southwest Quarter of the Northeast Quarter; .thence South 07 °44'56" West, 500.14 feet; thence ' North 87°50'09" West, 212:77 feet to the TRUE POINT OF BEGINNING; thence along a 14° curve to. the left whose center bears South 48 °22'43" East,. having a radius of 409.256 feet, througha central angle of 22 °12'21" an arc distancelof 158.61 feet; thence South 19°24'56" West,' 101.32 feet to the Northwest corner of Parcel..' 731, as recorded. under. King County Auditor's File No. 7512040188 ;.thence con tinuingSouth. 19 °24'56" West, 59.97 feet to a point of curve; thence along a. 12° curve to the-l'eft having a radius of 477.47 feet. through a central angle of 11.40'00" an arc distance of 97.22 feet; thence South 07 °44'56" West,1213.72 ' feet-to' the Southwest corner. of said Parcel 731; thence continuing South.07 °44'56" West along 48.23 point 4 a 12° curve to the I ri 8.23' feat to a' oint of curve; thence ht 9 having a 1033 of 477.4/ feet through central angle of fee arc es- tance of 108.8.33 feet; thence South 20 0°° 44'56" " West, , 399.00 feet t to to the then Southwwest corner of Parcel 733. as recorded .under King County Auditor's File No..7507030075 ;. thence continuing South 20.44'56" West, 511.97 feet to the Southwest corner of. Parcel. 752 as recorded under King-County ' Auditor's File Na. 7608160055; thence North 66 °31'27" West, 270.97 feet to a. point of'curve, thence along a .curve to '- the right having a radius of 50.00 feet through a central angle of 87'18'52 4 arc distance of - 76.20.feet; thence North 20 °47'25" East, 791.8 feet to a point of curve; thence along a curve' to the left having a radius of 1,164.55 feet n through a central angle of 13 °06'17" an arc distance of 266.36 feet; thence North 07 °41'08" East, 206.95 feet to a e point of curve; thence along a curve, to the right having a radius of,1,099.89 feet through r acentral angle of 06 °47'39" an•arc distance. of 130.43 feet,;. thence North. 14'28'47" East, 82.13 feet to a. . point'of curve ;' thence along a. curve to the right having a radius of 40:00 feet h • throug• a; central' angle 77 °41'04'' an' arc distance of 54.23' feat; thence South. e7 350.75''" feet to'the. TRUE:POINT OF BEGINNING. 0 ,06 °4T 39' ' saN. ssw MH R 1129.89 SEGALE PARK DRIB /E B N 07° 41' ()Er E� 206,95 Pa P. L•129 j wATER aLVe i� R - i 6455 __ A _ f _ • WATER MEEK` a 266.36 I �F CB CAS WILE WATER VA �., WATER VALVL° I a IRR CONTROL. VALVE t, 06 9739 , WATER METER - WATER METFR SPRN LER b1LVE9 nli WATER METER 9 MLVE R =1099.89 '- ; 433M5"10111.11.11111.1.1. - l 130 43.. J � GLR � I TERMfLVE �' � mil♦ O , FlRfTN1 PPE'ul � O a•N an RAIL y/ doe RESERVING an easement for sidewalk and utility purposes over the. Northerly 15.00 feet, over the Westerly. 15.00 feet and over the Southwesterly 15.00 feet thereof. RESERVING the right of ingress and,egress to maintain, instal , improve extend utilities... RESERVING and easement for railroad purposes, including, but not limited' to • maintrack, lead track and spur tracks, as well'as for access and storage, over ion thereof lying Southeasterl of. the Southeasterly 'buildin line that portion Y 4 Y 4 produced. RESERVING an easement for water line purposes 15 feet "wide, having 7.5 feet on each side of the following described centerline: monument t' the Northeast 'corner of'the Southwest of BEGINNING e s a Q me f the said Section 35• thence South 07 °44'56" Neat the Northeast Q n7' r t -500,14. feet; thence North 87°50'09" west, 329.73 feet; thence South 07.13'41" West, 15.06 feet to the TRUE POINT OF BEGINNING ; ',thence continuing South 07 °13'41" West, 246.77 feet to the terminus. RESERVING an easement for onoon a c ess purposes,. including ingress and egress over.. the following described portion thereof: ' BEGINNING'at a ant at the. Northeast corner of the Southwest Quarter of the Northeast Quarter of the, said Section 35; thence South 07 °44'56" West, 500.14 feet; thence North 87 °50'09" West, 212.77 f t to the TRUE POINT OF BEGINNING; thence along a 14 curve to the left whose nter bears South" 48 °22'43" East, having a. radius of 409.256 feet, through a central angle of:' 19 °54.'41 "' an arc distance of 142.22 feet; thence North 82°30'02". West, 66.82 feet ;'. thence 'NOLth .07.46'15" Ean't;. 117.5/ feet; thence South 87.50'097 East, 124': 74.,.£eet: to: the TRUE. POINT OF BEGINNING. TOGETHER WITH AND SUBJECT TO an easement for building setback purposes over era 60 feet. wide strip of 'land' surrounding and adjacent to the main buildingline, which ie: described as follows: BEGINNING at a monument at the Northeast corner of the Southwest Quarter of the. Northeast' Quarter of the said Section 35; thence South 07 °44'56" West, 500.14 feet; thence North. 87 °50'09" West, 337.51 feet ;. thence South 07.46'15 "' West,.' 117.51 feet' to the TRUE POINT. OF BEGINNING;, thence continuing South 07 °46'15 ". West,. 537.39 feet; thence South 20° 45'48 "', Nest,' 949.89 feet; thence . • � North 69°16'09 " West, 209.96 feet ;. thence North 20 °46'05" Seet, 116.00 feet; , Eas 0. 0 feet "thetce honth 69°13'56" 5" 2 0 feet; thence North 20 °46'05" East 637.87.. 3 e. North 20 °46'05" East, ' feet; .6R.f thence. thenc 69 • 1 ' 58 t 2 ast,R. thence N t t i 123 69 :4.0i•eet South 82°13'36" 'Sa6 77 feet; thence North 7°46'24" East,;:. 24.00 'Peat; ; thence South '82 ° 13''36.^ . " S t, 20..00 Peet; ; thence North 07 °46'24" East,' 434.74. feet;' thence North 82 °13'36" West, 20.00 feet; thence North 07°46'24" East, 101.05 feet;. thence South 82 °30'02" East, 210.01 feet to the TRUE POINT OF BEGINNING. (See sheet 2 fI,r continuation) : SITE. ADDRESS: 1034Q PABk , pRIVE .B 1 ATTACHMENT $1 SEPIMAS BUILDING 763 0- 22 °12'21" R. 409.26 L (58.6i 11-6W 9zo snares PARKING - .FJIGE EERS • R TER lULVES ° 77'4104" R 40.0 L• 54.23 H a l IL 1 I SURVEYORS CERTIFICATE I hereby certify that this map correctly represents a survey made by me or under my direction this 2 !st day of Registered Land Surveyor L.S. . No. LEGEND /0346 CB CATCH BASIN DS DOWN SPOUT STORM SEWER G NATURAL' GAS WATER '' FIRE HYDRANT SANITARY SEWER ELECTRICAL OUTSIDE. LIGHTING PROPERTY CORNER, CASE MONUMENT RAMSET NAIL: RECEIVED cm of ruKwDA JUN 1 7 1996 PERMIT CENTER • . NE CORNER, SW I ! NE 1/4, SECTION'.35 SAID MONUMENT ISgT' T23N R4E W. M. I . .. THE'CEN CENTERLINE PUBLIC. 9 ' !BOTH ST., A PUBLIC. TREET.'', WHOM, 2nnIj 11 J I ... .., . .. �,,,.. .�.,. : 5_7..44- .56".W .. ., _. JUL 2 1990 470.00 S00.14� - PLANNING 0 177, ' „ AN D OVER PARK WEST SEGALE.BUSI(VESS PARK -` A.T.A. SURVEY - BUILDING Na 44AWe,eNa 14Y1sW AMa01O IGIt' 1 260fX 9 23 77 u JU' NR FANG ,. .. . OAS VALVE %s 1 2" STEEL IO_,_ 0— / ywAT RESMT.J hne ea9C Ent n favor of King Count'' STEEL \, • � \ . \ ` \ as recorded under Auditors File No 780302 WATER PIPE \ \M\� 4\ �C 520=46 05 E 116.00 . PROPANE TANK N 20 47' 25" E \ ELECTRIC METER \ \ \ \ \ \ \ \ \\\\\\\\\\\\ P.S.P. a L VAULT •I" STEEL 4 0 SPRI L - ME R NORTHWESTERLY, BLDG. 'LINE CONCRETE OFFICE- WAREHOUSE SOUTHEASTERLY ' BI4DG. LINE \ \ \ \ \ \ \ \ \\ \ \\ / WATER WLVE / 'WATER METER SPRINKLER VN.VE ID C1. WATER PROPERTY- use IRK. CONTROL VAL I'' /2' PVC TYPICAL WATER SERVICE ATER VAL4£ • WATER METQt N69 °13 55'W 20.00 R/A13E7 NA A= 87,9 R =50.00 L =76.20 w 4TEX METEa WATER VALV •• j I - END PAVEMENT SAa SE'W. MH. IOEWALK4> -!. 1(2) The idth of said relocat d see t d the-physical surfacing thereof shall be imilar to that 06 rch i iti S _ _ t _ - �• R.R. SPUR TRACK SEGALE PARK DRIVE \ \\ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \\ \ \\ \ \ \ \\ \\ \\\\\M\\\\ E X I S T I N G RUSE \\ \ \\ \ \\ \ \ \ \ \ \ � \\\\\\\ \ ' (LEGAL DESCRIPTION CONTINUED) - • . BLDG.. N0. 752 ,TOGETHER WITH a. non exclusive easement for ingress ingrese,. egress, and utilities . purposes, 60 feet in width, having,30 feet on ach side of the following • described centerline:. . . • ' BEGINNING t a monument at the N' of the corner othe Southwest'500066r of the No theast Quarter of Section: 5, Township 23 North, Range 4 East, W.M., in King County, Washington; then a South 07144'56 'r West, 470.00 feet; thence ;North 87 °50'09" West, 628.86 fso4; "thence. South 14.28'47" West, 138.49. feet Ito a point of curve; thence along a curve to the left having a'radius. -00 :1,129.89 feet, through a central angle of- 6 ", an arc distance of 133.98 'feet; thence South 07.41'08" W e t, 206.95 feet to a point of curve; .thence. along a curve to the right hav ' a radius of 1,174.55 feet•through a central ' angle of 13.06'17 ",.an arc distance of 259.50 feet; thence South 20.47'25" west, 868.17 feet; thence Soutlj 66.31'27" East, 347.30 feet to. the.t reins :of this easement centerline - CEPT•,that portion thereof lying within South 180th Street. '. " ,SUBJECT, HOWEVER, to the right: of Owner and Owner's successors in title, to relocate said easement within: Segale. Business Park on the following terms - and conditions: ,. (1) Any such .relocation shall perpetuate similar rights of ingress, et' es5 l utilities. to 8 public, ra d; - . (3) The route Of said'relocated. easement shell'afford reasoeablydirect access to a,public road:" (4), The 'legal rights of Mortgagee's successor hereunde in and to, route:of. said relocated easement sh ll-be'S eb tantially the same as .with respecttothe route.of the initial easement (5) Said elgcated 8ssemenp shall•. 6e•appropria£ely documented by 's supple men6 to. this Assigindent containing a: revised legal deseription,and -shall by insured at'the expense of Owner by a titl s ranee: compeny'on the game'i basis as the original relocata6le easement: : (6) - -The xpenses. of such:relocation,. including the conetesotion altd sun -' facing' thereof, shall.. 80 the sole responsibility of Owner or Owner's • 868.17 R.R.SPUR TRACK _.� SEW.M.H. 1 1`'END R.R: LEAD TRACK 00500ENT'. • - — `20 ESMT.IN FAVOR %CHICA00 MILWAUKEE 8T, PAUL AND P RR ux — ,,ox PACIFIC 0.R AND OREGON ANp WASMNOTON R0. ANO NAVIGATION CO FIRE HYDRANT AND 'VALVE '.PROVIDED, HOWEVER, that no such relocation • shali be permitted' if; jn the.,. :.I `opinion of indepanden4 real estate appraiser ( 20 5 1 ) s ealected'by the ' Mortgage the fair market 00105 , 60 the cured property as of the date 1I. of beloW, t h e f, said easement would be 4 ared by r so ao6 such'rela , g "77 W ,tion'n' below the fair market Value. e. of theeaured'p party asef the. data of , exe6ution of this Assignment 05- determined by. the Mortgagee prior to the ' • '.execution date hereof '. . The expenses. of'such- appraiser shall b8 pai4,by the. {. OS - DS 8 1N NtS10t (1 .3 /4 . IRON PIPS U � PLASTIC CAP .L AIM. FILE NO. 7707080070 S\ \\\\ \\1\\\ \\\\\�\ \\\\\\�\\\\- LEGEND� WAR,SE" RewsfonYttb /v Gift ireccw7a 7g M,.) d zo -77 L?crvs/on _Ac7afifeo va.L... nlrr..9, d - 83 BLDG. NO 733 .CB CATCH -BASIN DS, DOWN SPOUT" STORM. SEWER! —G —' NATURAL', GAS ' 0. FIRE HYDRANT - - - -- SANITARY SEWER " —E — ,ELECTRICAL " OUTSIDE 'LIGHTING - Ills ' CASED MONUMENT • 03 PROPERTY 'CORNER • .: • .RAMSET NAIL. sS. l'TE ADDRESS; s0 PARKING /0 /- 'cOMPACTCAR*. APp pVE 1IW ECEIVED CITY R OF TUKWILA JUN 17 1996 PERMIT CENTER SURVEYORS CERTIFICATE I hereby certify' that this map correctly ' represents, a survey made by me or under my diiectian._th(s. 21st day. of -... /0396 Registered Land Surveyor L,S. No.. , 18200 - 18340 SEGALE PARK DRIVE 8 SEGALE. BUSINESS PARK AIA. SURVEY- BUILDING NO. 763" OeAlylllD/ar IOess6 , , I MAU / i "I' sco 2600 9 23 77 MA q"1-77.71.•