Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M96-0091 - BOEING #2-83
EJW2 City of f Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M96 -0091 Type: B- MECHAN Category: NRES Address: 7755 EAST MARGINAL WY S' Location: Parcel #: 000160 -0020 Contractor License No: MCKIN * *372N0 TENANT BOEING #2 -83 7755 EAST MARGINAL WY 5, TUKWILA, WA 98124 OWNER BOEING PO BOX 3707 - M/S 1F -09, SEATTLE WA 98124 CONTRACTOR MCKINSTRY COMPANY Phone: 206 762 -3311 5005 THIRD AVENUE SOUTH, PO BOX 24567, SEATTLE WA 98134 CONTACT KEVIN MCLEAN Phone: 206 762 -3311 5005 THIRD AVENUE SOUTH, SEATTLE, WA 98134 * * k * * * * *•k* k k k ** * k k k* k* k ** k ** ** k *'k *•k k* k***' k* *'k ** *'k * *** * *** * ** *** * ** ** * ** Permit Description: INSTALL "FOUR ''INDUSTRIAL FLUID , COOLERS AND ONE EXHAUST FAN. UMC Edition: 1994 * kk'k ** k•k'k *** k' * *'k k'k* * *•k,Ir A k************ ik.*'****.* ** * *'k'k*** * * ** * * * * *** * *** * * * ** Perm�t, Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to 'be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not The granting of this permit does not presume _to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: �.,G" - Date: �'i- 7. fP U MECHANICAL PERMIT Status: ISSUED Issued: 08/22/1996 Expires: 02/18/1997 (206) 431 -3670 220,000.00 Valuation: Total Permit Fee: •' 213.75 Title:_.�:L This permit shall become.null and void if the. work is not commenced within 180 days fr ~om the date of issuance,. -or- if: th'e work is suspended or abandoned for a period of 180 days from the last inspection. .Perini t No: M96- 0091. :Ad;dress: 77. Suite: Tenant: BOEING #2-83 Status: ISSUED Type: 6- MECHAN A p p l i e d : 07/16/1996 Par ~ce'1. ' #:. 060160 -0020 Issued: 08/22/1996. rk, •k •k 'k -k A •k `•k •k * * * •k •k. •k *'k •k •k •k •k •k 'k •k 'k * * 'k •k •k •k 'k •k A * * A 'k 'k •k •k •k k -k * •A •k •k k •k *. -k -k •k $ •k 'A •k k •k 'k •k k * k •k k k ' k''k •k •k Permit Conditions: 1,. No changes wi 1 1 be made to the plans Unless approved by the Architect or Engineer and the Tul;wf.,la,Bui Division, 2 All permits, inspection rec a,nd approv plans shall be available at the -jab s:i -te' prior . to the .tart of any con - struction. Thes'e. documents .dr ~e to`,'be maintained ; .and avai l able until f, i.n:al- is granted :y. Al 1 constructi.on to be` ",done 'An-conformance with approved p 1 ans and t req'u i r ~ements . of the . Uniform BO O 1. i i n `::��ode . ,('.1 994 Edition) as amended;` Uniform Meehanical Code' (1994 ti Edion) and Wash l;rtgton State E.riergy HCOde (1994 Edition`).: 4. Val i d i ty: of 'Perm' t.; '° The i ssUan`ce of a permit ors appr ava l ; » of p1ans°t.,, arid; computations shall :not con .strue,dtto` be a perm it-,.fai;; or an :approve ,'1 of, any v ola;tivri: of any' of';the provisions of '`the:.; building code or of anv other ordi'nance of the jurisdiction'. No perm it'.presuMirig giverrauthor�`ity to violate -or cancel the provisions' of,: this cod h a 1``j ,. be v a 'I i' d . Vii. MANUFACTURERS INSTALLATION SIN STRUCTIONS REOUSPED ON SITE FOR';THE,..6,U`ILbING - INSPEef ORS' REVIEW, 6. Eltr ica;, permits sha1.j': - -b e,.abt a1rigid through the Wash 1,99 St.t to Division of.,,.Labor aid ^Industr ie and all elecrtr w rcal oi so 11 ` - be in:�p,eted�'�b,�r agency• (,2'4 -t 30) . AMOUNT OWING: CONTACTED SUITE NO. DATE NOTIFIED BY: (init.) 2nd NOTIFICATION BY: (Init.) 3RD NOTIFICATION BY: 1init.) PROJECT NAME 750e -44 SITE ADDRESS 1155 E016-1- n lOLI SUITE NO. PLAN CHECK NUMBER CITY OF TUKvi. 4 Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT DATE ABUILDING - initial review O FIRE O PLANNING O OTHER 'BUILDING - final review BUILDING OFFICIAL /0 M cb l2°(ti APPROVED ( OU ED) INIT: INIT: INIT; La INIT: INIT: QUIR MENT / :C OMMEN CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: U Sprinklers U Detectors U /A FIRE DEPT. LETTER DATED: INSPECTOR: ZONING: BAR/LAND USE CONDITIONS? 0 Yes U No SCREENING REQUIRED? 0 Yes 0 No REFERENCE FILE NOS.: UMC EDITION (year): REVIEW COMPLETED 01/07/93 Project Name/Tenant: 416 ati.rt.6 2, rc 1v3 7 At cL U/ -of 5 6144 .�-g 3 Value of Construction: �� 0 , .- Site Address: C State/Zip: i .Er�1 z6sdii -L wA .5c) 394 )-33 l�(Itir Tax Parcel Number: 33.2 0 X -tAx prpR06"pWn Phone: Address: Street Ad dress : � z.A Aed44/IC ko �, City State/Zip: T /; /(ACC -4- Fax #: 0 Water - 7 5s Contact Person: K EV r e16- y c J ! 5 Phone: . _ 33/ f x a) 7 Street Address:�� - 3" n J City � 3 ip: 5 Air Fax #: 7/ - Contractor: m(( /� 4 y i� ` 1r LO‘ Phone: 70 — 3 Street Address: cos - ?mil � -�t . City State /Zip: �� Y 7 g i� Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: v Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT. REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) , _/� Description of work to be done: ( ) :Trt iu5•�2 z4.L Flu c.�� a (/) �S( clS rAr Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and store a location on se arate 8 1/2 X 11 a er indicatingyuantities & Material Safet Data Sheets 71 Above Ground Tanks U Antennas /Satellite Dishes Bulkhead/Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence 4echanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection/Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: . Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application ❑ Channelization/Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading/clearing ❑ Sanitary Side Sewer #. ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: Data application accepted: MISCPMT.DOC 7/10/96 CITY OF TIIKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Date application expires: F• • STAFF USE ONLY Project Number: (� f (✓ ,, Permit Number: rnq 00 I Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST. FOR MISCELLANEOUS PUBLIC WORKS PERMITS Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Application to =_ : (Initials) BUILDING OWNS OR AUTHORIZED AGENT: SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly Upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist, " No :: M'.9 Signature: — rM C4-14a- Antennas /Satellite Dishes Date: 7 _ �._ 9 ' El Print namq ` 7#6)1�1�5._ In 4.417../z. S-) Phone: 7 Fax #: JCS 4' )( Address:3-06, - 3" v . Commercial Reroof Cit /State /Zip: ... ,, fz . 92)/311 0 71 SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly Upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist, " No :: M'.9 El Antennas /Satellite Dishes Submit checklist No: M - 1 El Awnings /Canopies - No signage Commercial Tenant Improvement Permit . • Ei Bulkhead/Dock Submit checklist:. No: M-10" 0 Commercial Reroof Submit checklist No: .M-6 0 Demolition Submit checklist ..: No:. M -3,' M -3a E Fences - Over 6 feet in Height Submit checklist " No: _ M -9 0 Land Altering/Grading/Preloads Submit checklist No: M -2 0 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H-17 Mechanical (Residential & Commercial) Submit checklist " No. M - 8, Residential only - H -6, H -16 0 Miscellaneous Public Works Permits Submit checklist No: H - 9 , El Manufactured Housing (RED INSIGNIA ONLY) . Submit checklist. No: M - 5:. 0 Moving Oversized "Load /Hauling Submit checklist No:. M -5 0 Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced . . Residential Building Permit Submit checklist No: M -6 0 Retaining Walls - Over 4 feet in height Submit checklist No M -1 0 Temporary Facilities Submit checklist No: M -7 0 Temporary•Pedestrian Protection/Exit Systems Submit checklist No: M -4' Tree Cutting Submit checklist " No :. M -2 ALL MISCELLANEOUS P 'IT APPLICATIONS MUST BE SUB ' ED WITH THE FOLLOWING: • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) 71- ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED Copy of Washington State Department of Labor and Industries Valid Contractor's License. if not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent. If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT,DOC 7/10/96 :4*A * +4kr* *tit *. * *' *• /c* ** * * * *4. * *AA * * *A• k:. *k * **AA* ***A ** ** *A* * **A * *; * :ITY OF T.UKW3 LA.. WA (9.- 00 kk ** * * ****k*kk A *A ft * /r•A * * * * *A ;A*. *A**A*A * *A * * *A *** * ** *A * ** TRANSMIT t uml er: R9600460 ARIoLrit: 213.75 08/22/96 11: PayMent Method:, CHECK. Notation: MCKINSTRY CO Init: "MC Permit No: M96 -0031 Type: ! -MI:CHAU MECHANICAL, PERMIT Parcel Ng: 0001'60-0020 S i t e . Address: • 775': EAST MARGINAL WY S Total Fees: 213.75 This Payment. 2137.5 Total ALL Pmts: 213. / 7�5 Balance; .00 *A 4o1**A* ***k *4'**k***** brit ** ** * ** *A*A.k.A *A *A*** *4 ** * *•A 4./rA *A * *•A Account Code Descry i p-t i on Amount 000/345 «030 "AN CHECK •- NONRE" 42.75 000/322.100 ' 'MECHANI.CAL - NONRE$ 171.00 TRANSMIT '.220.08/23:941.5 TOTAL 213.75 • . CITY OF TUKWILA RECEIPT PW 11CII 213.75 CHECK 213.75 08/23/96 16:43 0096 25 ec : (--.... r1G Li- g9 p o,i pect el ..A, es : l • �, ( �� // ilia � lw! ` ate c�l d :f ' / a6.7'..n.____ P.m. S ecia ins a in !�`'� .t'G� .� 110 OIV Ve r be.:)'. Date d : 9 wante I X 11 / Re Phone Ng.: a' - :-), A i I INSPECTION RECORD Retain a copy with permit Nl '110- ) INSPECTION NO, PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 CO MENTS:..._ -.-- -- l Approved per applicable codes. Corrections required prior to approval. (206) 431 -3670 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Pr aP i � ei g- Type of inspectioh � �, Date called: il t, - 1 - • a CAWTAAAr,i►A,A, w, pecial Instructions: Date wanted: 1j aim, , 1 am` Requester: ;-��,, f uester: 66He4a. pe: ( 449-5= Izm Inspector: INSPECTIO NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit � - I [ ( o - oCA t PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Projt�L.� : 8 ' ` Ty.e • f inspection: I v") Address: •� 9 Date called: A30 Special instructions: L✓`� 4.A.4.... Date wanted: m p,m, Requester ivi . I Phone No.: N�t�rk (a(o 3- )? 1 v),.3.311 II INSPECTION NO, Approved per applicable codes. INSPECTION RECORD Retain a copy with permit M96 -oo9i PERMIT NO, CITY OF BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 COMMENTS: re -< dYL_.. Ea-u 1 to 1 - 4 �,�"�_ Corrections required prior to approval. Inspector: Date: f / to $42.00 REINSPECTION FEE REQUIRED. Prior to ins p ec n, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt,No.: Date: . � ' ' REG�I.VEp • , ' "' - ' qF T,UKWJL PERMIT CENT. 9 = . • . The above entity has been issued the business registrations or licenses listed.; .. - DEPARTMENT OF LICENSING, BUSINESS & PROFESSIONS DIVISION, ' ' '- ` " L .. P.O. BOX 9034 OLYMPIA, WA 98507.9034 (360) 753 -4401 ' . 'i . c ` �; ..x . J ^ , . d kW'. a a:. a. • C� A =V= 610idLa2s1s.41 . y. 4 0N41fIt.T, ^_.!._ �•�i .•5^:••f. .,. -_ _ "...,� 0002932 25 STATE OF WASHINGTON MCKINSTRY CO. 5005 3RD AVE S PO BOX 24567 SEATTLE WA 98124 DOMESTIC PROFIT CORPORATION RENEWED BY AUTHORITY OF SECRETARY OF STATE REGISTERED TRADE NAMES: MCKINSTRY CO WESTERN VENTILATION & SHEET METAL CO MASTER LICEN,..._ SERVICE REGISTRATIONS AND LICENSES ORGANIZATION TYPE DOMESTIC PROFIT CORPORATION UNIFIED BUSINESS ID #: BUSINESS ID #: EXPIRES : 179 012 657 001 04-30-1997 5/1/96 I certify these to be true c By: Accounting Manager DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A • STATE OF WAS es of the original uments. Jr itty A% - 000(3.92) VICINITY PLAN °t :t n l II / - SYM rnq 7.00qI REVISION BY APPROVED SY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MOTOR ROOM REVISION BOEING COMMERCIAL AIRPLANE GROUP PLANT II TUKWILA, WA APPROVED DATE ® ®EZVG FACILITIES DEPARTMENT SYMBOLS LEGEND 1A10 A200 TAKEN FROM SHEET - SHOWN ON SHEET TAKEN FROM SHEET TAKEN FROM SHEET TAKEN FROM SHEET - IA.10 A500 SHOWN ON SHEET REFERENCE TO DETAIL 1A10 A450 I I PLAN A450 A370 SHOWN ON SHEET ROOM NAME ROOM NAME AND NUMBER IROOMNOI (DOOR DOOR NUMBER (GRID GRID AND CENTERLINE DIMENSION . 1 DIMENSION LINE SHOWN 'ON SHEET DETAIL ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED BUILDING AND WALL SECTIONS INTERIOR /EXTERIOR ELEVATION CONSTRUCTION ABOVE OR BELOW AND /OR TO BE REMOVED AND /OR REINSTALLED DRAWN or C. PRESTON CHEERED J. FEENEY LNGH J. FEENEY CHECKED J. FEENEY APPROVED J. FEENEY J DATE 11 -22 -95 11 -22 -95 11 -22 -95 11 -22 -95 2 -21 -96 2 -21 -96 MATERIALS LEGEND EARTH, DIRT CONCRETE MASONRY 11�1LL1� UNIT - CMU 1 5>S> >1 ROMA CONCRETE CERMIC TILE INSULATION: BATT, LOOSE INSULATION: RIGID METAL, STEEL, IRON I GYPSUM WALL BOARD JJJIIIIJ� WOOD: FINISH WOOD ROUGH LP - 3: A trio, the Plan Check approvals are ; t KY EVE E, x:IO,YU,A n1 scio and approval of cf doee LNA e ,,,, , .._, the violation of any .iLI,N,Lo,O ,..aid AR IA , ' , c aa. Receipt of con - 1 r 0,,,B ,,,PV of «P ov "1 plans acknowledged. fines No -1-°a PLYWOOD ® — — GLASS ACOUSTICAL TILE s 1 Remise MECHANIC , ELECI�ICA tirPLUNIB 0 G.'- PIPING I CITY OF TUIONIL 0 BUILDING °NISI , U; tUhVhJ' p.P1'ROA I \SG 2 0 1996 -- PING DIVISION TITLE COVER SHEET RECEIVED CITY OF TUKWILA 11I1.. I C 1996 PERMIT CENTER AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT COL PLANT II SHEEP JOB N0. rursrm Architects Engineers I Pioneers LAST REVISION AO PL2 -94164 SYMBOL DWG NO 2.83.A0 DATE COMP NO ¶ o_ SHT SHEET ABBREV I AT I ONS LEGEND GENERAL NOTES: SYMBOL DESCRIPTION AFF ABOVE FINISHED FLOOR AFCF AUTOMATIC FLOW CONTROL VALVE NEW OR EXISTING PIPING DESIGNATED BY NOTE AV AUTOMATIC VENT BLGD BUILDING HIDDEN OR BELOW GRADE BOP BOTTOM OF PIPE CFM CUBIC FEET PER MINUTE 2 l BREAK IN PIPE CO VA CHECK VALVE C LWR C OOLING WATER RETURN (TO FLUID COOLER) CLEAN OUT ( ) CONT CONTINUED CW COLD WATER DOMESTIC CLWS COOLING WATER SUPPLY (FROM FLUID COOLER) CWTR COOLING WATER TOWER RETURN CWTS COOLING WATER TOWER SUPPLY — DIRECTION OF FLOW DF DRINKING FOUNTAIN • cW D I A DIAMETER COLD WATER DOMESTIC DN DOWN DWG DRAWING SAN — SANITARY WASTE (BELOW GROUND) EL ELEVATION ELL ELBOW RL — — STORM SEWER (BELOW GROUND) EWT ENTERING WATER TEMPERATURE EXIST EXISTING v — OR - - -- VENT FCO FLOOR CLEAN OUT FD FLOOR DRAIN INSULATED PIPE FGPRV FUEL GAS PRESSURE 1REDUCING VALVE FIN FINISHED cm ELBOW, TURNING UP OR TOWARD FLR FLOOR FPHB FREEZE PROOF HOSE BIB C I TURNING ELBOW, DOWN OR AWAY FS I FT FEET I1 UNION GAL GALLON GPM GALLONS PER MINUTE pa GATE VALVE I.D. INTERNAL DIAMETER ID DRAIN (INDIRECT) T., CHECK VALVE I.E.,IE INVERT ELEVATION i PS IRON P I P E S I Z E Doi— --.r GLOBE VALVE OPEN /CLOSED LAV LAVATORY LWT LEAVING WATER TEMPERATURE ty TRIPLE DUTY VALVE MFGR MANUFACTURER MPT MALE PIPE THREADS N.O. NORMALLY OPEN /a HOSE BIBS NPT NATIONAL PIPE THREAD NTS NOT TO SCALE PRESSURE RELIEF VALVE OFRD OVERFLOW ROOF DRAIN REDUCED PRESSURE OFRL OVERFLOW ROOF LEADER BACKFLOW PREVENTER PL PLACES POC POINT OF CONNECTION N I STRAINER, WYE PSIG POUNDS PER SQUARE INCH GAUGE REQ'D REQUIRED RL RAIN LEADER !I ELBOW 90' REDUCER RM ROOM D RS RISING STEM TEE RPBP REDUCED PRESSURE BACKFLOW PREVENTER I SAN SANITARY t ` • ✓ , PRV O • N D OPENING (SELF CONTAINED) AV A AN 1 TOR SINK) BALANCING VALVE T & P TEMPERATURE AND PRESSURE cIa TEFC TOTALLY ENCLOSED FAN COOLED THREE TYP TYPICAL WAY CONTROL VALVE U/G UNDERGROUND GR I PIPE UDS UTILITY DISTRIBUTION SYSTEM I GROOVED COUPLING CONNECTIONS V - VENT VB VACUUM BREAKER I I THREADED OR SOCKET WELDED PIPE CONNECTIONS VTR VENT THRU ROOF PIPE W WASTE • • WELDED CONNECTIONS FLOW SENSOR F �= t� _ IDENTIFIERS PRESSURE GAUGE WITH VALVE THERMOMETER, SECTION VIEW CALLOUT LINE MOUNT SECTION LETTER FILTER a O IN LINE SHEET SECTION SHOWN ON SHEET SECTION TAKEN FROM — FLEX HOSE 4 J i . FLEXIBLE CONNECTOR a DETAIL CALLOUT DETAIL NUMBER Q c ‘'''s-j\\\ • ® FLOOR CLEANOUT SHEET DETAIL SHOWN ON G11 OF 0V E FD OR :�, FLOOR DRAIN A P P R % SHEET DETAIL TAKEN FROM (� o p Z 1996 ct 9IFD OR y FUNNEL FLOOR DRAIN ,,, .,, c ~ © EQUIPMENT MARK NUMBER Q y PUMP ....-- P,UILDIN : 1 m} VALVE IN RISER SLOPE DIRECTION OF SLOPE DOWN mq b .....ocil I RECEIVED r1F SUCTION DIFFUSER c U u OF C TUKWILA L z� 1996 1956 w SIGHT GLASS PERMIT CENTER HN a Architects Engineers & Planners $VIA REVISION BY APPROVED PATE SYM RLRROH BY APPROVED RATE R C. 4 a ' h ACCEPTABILITY THIS DESIGN AND /OR THIS IS APPROVED DRAWN BY W. DUTTON DATE 11 -22 -9 SUBTITLE MECHANICAL LEGEND L LAST REV SON SWAB A `— 4/18/96 A FINAL REVIEW UPDATE SEC SEC 4/18/96 CRECKLD S. CASSADY SG CASSADY 11 -22 -95 11 22 95 C TI AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II SHEET / 1 Y / / Ov ® ®E ® � ( Br oEpr. DATE FACILITIES DEPARTMENT , J�ED ' *J ` "44 ,, ° � > r ° � : � � �� ` � 8 ' 0HAL cN CHECKED s. CASSADY 11-22-95 S. CASSADY 2 -21 -96 JOB No. PL2 -94164 CORP NO. JPRFQy €NEY 2 -21 -96 D N° 2.83.M1 cross v., COOLING SYSTEM STAGES 1 2 3 4 5 6 7 8 9 10 II 12 COOLING WATER FKI05 BYPASS VALVE X X X X X X X X X X 94 CWP-I ON MCI 20 X X X X X X X X X X X X CWP -2 ON MCI30 F FLOW RATE RATIO (FRACTION) G X X X I F C - I FLOW VALVE FK210 X X X X X X X X X X INDICATE I F C - I EVAP PUMP ON MC200 X X X X X X X X X X IFC -I PONY MOTOR ON MC202 L LEVEL X X X X X X X IFC -I MAIN MOTOR ON SC201 MIDDLE, INTERMEDIATE N CONSISTENCY 0 X X X IFC -2 FLOW VALVE ON FK230 OPEN P X X X X X X X X X IFC -2 EVAP PUMP ON MC220 R X X X X X X X X X IFC -2 PONY MOTOR ON MC222 T TEMPERATURE X X X X X X IFC -2 MAIN MOTOR ON SC221 MULTIFUNCTION V VIBRATION. MECHANICAL ANALYSIS VALVE, DAMPER, LOUVER W WEIGHT,FORCE, WATTS X X IFC -3 FLOW VALVE ON FK250 X CALCULATED VARIABLE X AXIS X X X X X IFC -3 EVAP PUMP ON FC240 Z POSITION Z AXIS DRIVER, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT X X X X X IFC -3 PONY MOTOR ON MC242 X X X X IFC -3 MAIN MOTOR ON SC241 X COOLING SYSTEM STAGES I 2 3 4 5 6 7 8 9 1 0 I I 12 85 85.5 86 87 88 89 90 91 92 93 94 95 �X) INNj /XxX� NIy REVISION GENERAL INSTRUMENT IDENTIFICATION LETTERS (SEE EXAMPLES BELOW TABLE) FIELD MOUNTED INSTRUMENT LOOP NUMBER PANEL MOUNTED INSTRUMENT CONTROL SYSTEM FUNCTION NOT OPERATOR ACCESSIBLE CONTROL SYSTEM FUNCTION OPERATOR ACCESSIBLE PROGRAMMABLE LOGIC CONTROLLER FUNCTION NOT OPERATOR ACCESSIBLE PROGRAMMABLE LOGIC CONTROLLER FUNCTION OPERATOR ACCESSIBLE LOGICAL INTERLOCK DIRECT CONNECT TO PROCESS ELECTRONIC SIGNAL CONTROLLER SOFTWARE INSTRUMENTATION SYMBOLS A FINAL REVIEW UPDATE 4/18/9 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 2 -21 -96 AWE /A/G FACILITIES DEPARTMENT S. CASSADY S. CASSADY I J PTTNEY 2 -21 -96 Moib-.00 REVISION USAGE EXAMPLES: PIC = PRESSURE INDICATING CONTROLLER AIR = ANALYTICAL INDICATING RECORDER FQI = FLOW TOTALIZING INDICATOR LRC = LEVEL RECORDING CONTROLLER FS = FLOW SWITCH BY INSTRUMENT IDENTIFICATION LETTERS r�x[s 8/20/97 ' 22 SUBTIT. GENERAL NOTES: I MOTOR PLC -CL SHALL CONTROL THE FOLLOWING COMPONENTS WITH PROPORTIONAL CONTROL ACCORDING TO THE FOLLOWING TABLE: COOLING SYSTEM STAGE TEMPERATURE SETPOINTS PLC CONTROL ACTION SHALL MAINTAIN CLWR TEMPERATURE AT 95 DEGREES F. UPON HIGH TEMPERATURE ALARM, PLC TEMPERATURE SETPOINT WILL BE RESET I DEGREE F LESS THAN CURRENT SETPOINT. PLC SHALL ALSO ROTATE LEAD LAG POSITION OF THE FOLLOWING SYSTEMS: A) CWP -I, 2 AND 3 B) IFC -I, IFC -2, IFC -3 AND IFC -4 2 INDUSTRIAL FLUID COOLER CONTROL PANEL INCLUDES THE FOLLOWING FUNCTIONS: 3. WATER LEVEL SENSOR FUNCTIONS AS FOLLOWS: A) DRY CONTACT FOR HIGH WATER ALARM B) DRY CONTACT FOR MAKE UP WATER DEMAND C) DRY CONTACT FOR LOW WATER ALARM 3 INDUSTRIAL FLUID COOLER CONTROLS CONTAINED IN PCLS -CL INCLUDES THE FOLLOWING FUNCTIONS: I. TIME DELAY RELAY FOR LOW TO HIGH SPEED FAN TRANSITION 2. FREEZE PROTECTION THERMOSTATIC CONTROL OF PAN HEATER 3. WATER LEVEL SENSOR FUNCTIONS AS FOLLOWS: A) WATER LOW LIMIT SHUT OFF OF THE PAN HEATER B) MAKE UP WATER ON OR OFF. SOLINOID VALVE (SV205) 4. ENABLE FLUID COOLER FOR COOLING OPERATION. ENABLING FLUID COOLER ALLOWS THE FOLLOWING EQUIPMENT OPERATION IN ADDITION TO FUNCTIONS 2 AND 3A (MC200): A) FUNCTION I B) FUNCTION 3B C) EVAPORATIVE SPRAY PUMP ON 5. FLUID COOLER AIR FLOW OFF /LOW /HIGH (MC202, SC201) 6. INTERFACE RELAY FOR LOW WATER ALARM IN BASIN (LAL203) 4 EXHAUST FAN EF -I RUNS CONTINUOUSLY INSTRUMENTATION LEGEND C R ECEIVED ITY OF TUKWILA JUL 1 6 1996 PERMIT CENTER TITLE AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II LI 10\ iUKWI D D,PPRO AUO 2 0 1996 ut nINiG DNIS HNITB Architects Engineers B Planners RYUBOE LAST REVP,JON A SHEET M 1a JOB N0. PL2 -94164 DWG NO 2.83.M 1 a DATE 4/18/96 OF COUP NO. FIRST LETTER SUCCEEDING LEI TERS MEASURED OR INITIATING VARIABLE MODIFIER READOUT OR PASSIVE FUNCTION OUTPUT FUNCTION MODIFIER A ANALYSIS ALARM B BURNER, COMBUSTION C CONDUCTIVITY CONTROL CLOSED D DENSITY DIFFERENTIAL E VOLTAGE (EMF) SENSOR (PRIMARY ELEMENT) F FLOW RATE RATIO (FRACTION) G . GROUND POTENTIAL GLASS, VIEWING DEVICE H HAND HIGH I ELECTRICAL CURRENT INDICATE J POWER K TIME,TIME SCHEDULE, MECHANICAL INTERLOCK TIME RATE OF CHANGE CONTROL STATION L LEVEL LIGHT LOW M MOTOR MOMENTARY MIDDLE, INTERMEDIATE N CONSISTENCY 0 ORIFICE, RESTRICTION OPEN P PRESSURE, VACUUM POINT (TEST) CONNECTION 0 QUANTITY INTEGRATE, TOTALIZE R RADIATION RECORD REGULATING S - SPEED, FREQUENCY SAFETY SWITCH T TEMPERATURE TRANSMIT U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION V VIBRATION. MECHANICAL ANALYSIS VALVE, DAMPER, LOUVER W WEIGHT,FORCE, WATTS WELL X CALCULATED VARIABLE X AXIS Y EVENT,STATE, PRESENCE Y AXIS RELAY, COMPUTE, CONVERT Z POSITION Z AXIS DRIVER, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT ' �X) INNj /XxX� NIy REVISION GENERAL INSTRUMENT IDENTIFICATION LETTERS (SEE EXAMPLES BELOW TABLE) FIELD MOUNTED INSTRUMENT LOOP NUMBER PANEL MOUNTED INSTRUMENT CONTROL SYSTEM FUNCTION NOT OPERATOR ACCESSIBLE CONTROL SYSTEM FUNCTION OPERATOR ACCESSIBLE PROGRAMMABLE LOGIC CONTROLLER FUNCTION NOT OPERATOR ACCESSIBLE PROGRAMMABLE LOGIC CONTROLLER FUNCTION OPERATOR ACCESSIBLE LOGICAL INTERLOCK DIRECT CONNECT TO PROCESS ELECTRONIC SIGNAL CONTROLLER SOFTWARE INSTRUMENTATION SYMBOLS A FINAL REVIEW UPDATE 4/18/9 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 2 -21 -96 AWE /A/G FACILITIES DEPARTMENT S. CASSADY S. CASSADY I J PTTNEY 2 -21 -96 Moib-.00 REVISION USAGE EXAMPLES: PIC = PRESSURE INDICATING CONTROLLER AIR = ANALYTICAL INDICATING RECORDER FQI = FLOW TOTALIZING INDICATOR LRC = LEVEL RECORDING CONTROLLER FS = FLOW SWITCH BY INSTRUMENT IDENTIFICATION LETTERS r�x[s 8/20/97 ' 22 SUBTIT. GENERAL NOTES: I MOTOR PLC -CL SHALL CONTROL THE FOLLOWING COMPONENTS WITH PROPORTIONAL CONTROL ACCORDING TO THE FOLLOWING TABLE: COOLING SYSTEM STAGE TEMPERATURE SETPOINTS PLC CONTROL ACTION SHALL MAINTAIN CLWR TEMPERATURE AT 95 DEGREES F. UPON HIGH TEMPERATURE ALARM, PLC TEMPERATURE SETPOINT WILL BE RESET I DEGREE F LESS THAN CURRENT SETPOINT. PLC SHALL ALSO ROTATE LEAD LAG POSITION OF THE FOLLOWING SYSTEMS: A) CWP -I, 2 AND 3 B) IFC -I, IFC -2, IFC -3 AND IFC -4 2 INDUSTRIAL FLUID COOLER CONTROL PANEL INCLUDES THE FOLLOWING FUNCTIONS: 3. WATER LEVEL SENSOR FUNCTIONS AS FOLLOWS: A) DRY CONTACT FOR HIGH WATER ALARM B) DRY CONTACT FOR MAKE UP WATER DEMAND C) DRY CONTACT FOR LOW WATER ALARM 3 INDUSTRIAL FLUID COOLER CONTROLS CONTAINED IN PCLS -CL INCLUDES THE FOLLOWING FUNCTIONS: I. TIME DELAY RELAY FOR LOW TO HIGH SPEED FAN TRANSITION 2. FREEZE PROTECTION THERMOSTATIC CONTROL OF PAN HEATER 3. WATER LEVEL SENSOR FUNCTIONS AS FOLLOWS: A) WATER LOW LIMIT SHUT OFF OF THE PAN HEATER B) MAKE UP WATER ON OR OFF. SOLINOID VALVE (SV205) 4. ENABLE FLUID COOLER FOR COOLING OPERATION. ENABLING FLUID COOLER ALLOWS THE FOLLOWING EQUIPMENT OPERATION IN ADDITION TO FUNCTIONS 2 AND 3A (MC200): A) FUNCTION I B) FUNCTION 3B C) EVAPORATIVE SPRAY PUMP ON 5. FLUID COOLER AIR FLOW OFF /LOW /HIGH (MC202, SC201) 6. INTERFACE RELAY FOR LOW WATER ALARM IN BASIN (LAL203) 4 EXHAUST FAN EF -I RUNS CONTINUOUSLY INSTRUMENTATION LEGEND C R ECEIVED ITY OF TUKWILA JUL 1 6 1996 PERMIT CENTER TITLE AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II LI 10\ iUKWI D D,PPRO AUO 2 0 1996 ut nINiG DNIS HNITB Architects Engineers B Planners RYUBOE LAST REVP,JON A SHEET M 1a JOB N0. PL2 -94164 DWG NO 2.83.M 1 a DATE 4/18/96 OF COUP NO. I'YDRONIC EQUIPMENT SCHEDULE PLAN MARK LOCATION TYPE SERVICE TANK GAL TANK DIMENSIONS TANK FITTING GPM MAX PD (FT) INLET/ OUTLET REMARKS MANUFACTURER /MODEL J NORTH MECHANICAL AREA AIR SEPARATOR COOLING BRINE - - - 1690 2 10" 0 TACO AC1OF p FIRST FLOOR MOTOR ROOM CHEMICAL FEEDER COOLING BRINE 5 10 "0 X 24" 3/4" - - 3/4" 200 PSI DEARBORN SHOTFEEDER C1.2 ET-1 FIRST FLOOR MOTOR ROOM EXPANSION TANK COOLING BRINE 53 53 "H X 24 "W 1 "' - - - 150 PSIG ASME RATED,HORIZONTAL, 10 AMTROL 200L ./PRV -1 FIRST FLOOR MOTOR ROOM PRV COOLING BRINE - - - - - - SET 15 PSIG WATTS U5 �1 IFC - ALGECIDE TREATMENT CARTRIDGE EVAPORATIVE FLUID - - - - - - - BAC IOBIO i RPBP FIRST FLOOR MOTOR" ROOM REDUCED PRESSURE COOLING BRINE AND EVAPORATIVE FLUID - - - 100 37 - IFC -4 WATTS 9090T -S <PUMP CHEDULE INDUSTRIAL FLUID COOLER CHEDULE LOCATION PLAN MARK LOCATION TYPE SHUTOFF HEAD(FT) DESIGN WET BULB F EWT F LWT F MOTOR REMARKS MANUFACTURER /MODEL FAN EVAPOI�AT.VE RECIRC_ PUMP OPER. WEIGHT (LBS -) REMARKS MANUFACTURER /MODEL GPM PD (FT} CFM HP 619 VOLTAGE / PHASE GPM HP VOLTAGE /PHASE IFC -1 NORTH MECHANICAL AREA FORCED DRAFT, CLOSED CRKT. 72 95.2 85 346 i0 44,000 20 127 460/3 303 2 460/3 15,130 1, 2 BAC 1342M IFC -2 NORTH MECHANICAL AREA FORCED DRAFT, CLOSED CRKT. 72 95.2 85 346 10 44000 20 9.6 460/3 303 2 460/3 15,130 1, 2 BAC 1342M IFC -3 NORTH MECHANICAL AREA FORCED DRAFT, CLOSED CRKT. 72 95.2 85 346 10 44000 20 460/3 303 2 460/3 15,130 1, 2 BAC 1342M IFC -4 NORTH .MECHANICAL AREA FORCED DRAFT, CLOSED CRKT. 72 95.2 85 346 10 44,000 20 460/3 I 303 2 460/3 15,130 1, 2 BAC 1342M <PUMP CHEDULE PLAN MARK LOCATION SERVICE TYPE DESIGN CONDITIONS SHUTOFF HEAD(FT) NPSHR (FT) MAX MINIMUM WORKING PRESSURE (PSIGI APPROX IMPELLER DIA (IN) MOTOR REMARKS MANUFACTURER /MODEL GPM HEAD (FT) MAX HP VOLTAGE/ PHASE RPM - CWP-1 NORTH MECHANICAL AREA COOLING BRINE CENTRIFUGAL 619 127 140 10 175 9.6 I 30 460/3 1750 CLOSE COUPLED nn PACO VL 5012 -7 CWP -2 NORTH MECHANICAL AREA COOLING BRINE CENTRIFUGAL 619 127 140 10 175 9 -6 30 460/3 1750 CLOSE COUPLED (V) PACO VL 5012 -7 CWP -3 NORTH MECHANICAL AREA COOLING BRINE CENTRIFUGAL 619 127 140 10 175 9.6 30 460/3 1750 CLOSE COUPLED nn PACO VL 5012 -7 FLUID COOLER BASIN PUMP SOLIDS SEPARATOR SCHEDULE PLAN MARK LOCATION • SERVICE DESIGN CONDITIONS RECOVERY TANK REMARKS MANUFACTURER /MODEL GPM MAX WORKING PRESSURE (PSI) FLOW (GPM) MAXIMUM FILTER SIZE (MICRON) TYPE CB' -1 NORTH MECHANICAL AREA IFC -1 20 50 10 50 NYLON (17,0 GRISWOLD CSR -75E F'P -2 NORTH MECHANICAL AREA IFC -2 20 50 10 50 NYLON CO GRISWOLD CSR -75E F B' 3 NORTH MECHANICAL AREA IFC -3 20 50 10 50 NYLON 03 GRISWOLD CSR -75E FCBP -4 NORTH MECHANICAL AREA IFC -4 20 50 10 50 NYLON CO GRISWOLD CSR -75E EXHAUST FAN SCHEDULE PLAN MARK LOCATION AREA SERVED FAN TYPE CAPACITY CFM STATIC PRESS. IN. WG. MOTOR ELECTRICAL CHARACTERISTICS I I REMARKS MANUFACTURER /MODEL WATTS RPM TYPE VOLTS PHASE HERTZ EF -1 FIRST FLOOR BATTERY RM. CENTRIFUGAL FAN 100 0.2 50 1200 115 60 10 PENN: ZEPHERETTE ZT LOUVER SCHEDULE PLAN MARK LOCATION MAX CFM INTAKE RELIEF EXHAUST OPENING LOUVER DEPTH REMARKS • MANUFACTURER /MODEL WIDE IN. WIDE IN. L -1 BATTERY ROOM 100 EXHAUST 12 12 1 -1/2" RUSKIN ELF 155 SYM Zfi NOTES: 1. OPTIONAL EQUIPMENT INCLUDES: SEE SPECIFICATIONS FOR ACCESSORIES. MOTOR STARTERS AND CONTROL CONTACTORS SHALL BE ALLEN BRADLEY COMPONENTS LOCATED IN MOTOR ROOM. IFC SHALL HAVE ELECTRICAL CONDUIT CONNECTIONS FOR REMOTE MOUNTED CONTROLS. FACTORY MOUNTED CONTROL PANEL SHALL HAVE 120 V WATER LEVEL CONTROLS WITH THREE CONTROL SIGNAL CONTACTORS. 2. PONY MOTOR INCLUDED IN FAN DRIVE SYSTEM. 7.5 HP 10 VERTICAL BLADDER TYPE 02 INTEGRAL BASE RING WITH MOUNTING FIXTURES 10 VERTICAL, END SUCTION. 0 ACCESSORIES: BRONZE FITTED, GAUGE TAPS FOR INLET AND OUTLET, NS UNIMOUNT HIGH EFFICIENCY MOTOR, 1.25 SF. CAST IRON BASE 10 ACCESSORIES: IN -LINE INSTALLATION KIT, WALL CAP BACKDRAFT DAMPER ACCESSORIES: WEATHERPROOF ON /OFF SWITCH, 1 HP RATED 120V MOTOR CONTACTOR. © SEPARATION FILTRATION EFFICIENCY; SOLIDS 45 MICRONS AND HEAVIER THAN 1.20 SPECIFIC GRAVITY. 10 LOUVER TO BE ALUMINUM CONSTRUCTION, AND COMPLETE WITH BIRDSCREEN 02 ANODIZED ALUMINUM FINISH REVISION A FINAL REVIEW UPDATE B®E/A/G FACILITIES DEPARTMENT ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRA HY '111122-95 J. CALDWELL 11 -22 -95 11 -22 -95 11- 2 -95 S. CASSADY 2 -21 -96 2 -21 -96 EQUIPMENT SCHEDULES GENERAL NOTES: RECEIVED CITY OP TURWILA 1996 PERMIT CENTER 'LE AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER , COL PLANT II E1 OFIU PPP " AUG 2 0 5996 Boo\NG DIVISION ■ 1 ® gra l-1 Architect. Engineer. & Planner. SYMBOL LAST REVISION SHEET M1b PL2 -94164 DWG N0. 2.83.M 1 b CONTROL VALVE SCHEDULE DEVICE NUMBER LOCATION DEVICE FUNCTION OPERATION RANGE VOLTAGE / PHASE ADDITIONAL PARAMETERS REMARKS MANUFACTURER /MODEL FCV -105 COOLING WATER PUMP DISCH MANIFOLD 3 -WAY DIVERTING FLOW CONTROL VALVE FLOW DIVERSION 4 - 20 MA 115 VAC 1 PH 66 PSIG MAX. DIFFERENTIAL PRESSURE (1) NELES- JAMESBURY 10 " -DM- 150 -FD- 2236 -T -T W/© FCV -210 FLUID COOLER IFC -1 CWS LINE FLOW CONTROL VALVE OPEN -CLOSE (7) 115 VAC 1 PH 66 PSIG MAX. DIFFERENTIAL PRESSURE a NELES - JAMESBURY 6 "- 815- L- 11- 21 -EH -TT W/R FCV -230 FLUID COOLER !EC-2 CWS UNE FLOW CONTROL VALVE OPEN -CLOSE 0 115 VAC 1 PH 66 PSIG MAX. DIFFERENTIAL PRESSURE a NELES - JAMESBURY 6 "- 815- L- 11- 21 -EH -TT W /( FCV -250 FLUID COOLER IFC -4 CWS LINE FLOW CONTROL VALVE OPEN -CLOSE (T 115 VAC 1 PH 66 PSIG MAX- DIFFERENTIAL PRESSURE a NELES - JAMESBURY 6 "- 815- L- 11- 21 -EH -TT W /(. FCV -270 FLUID COOLER IFC -3 CWS LINE FLOW CONTROL VALVE OPEN -CLOSE 0 115 VAC 1 PH 66 PSIG MAX. DIFFERENTIAL PRESSURE (3 NELES- JAMESBURY 6 "- 815- L- 11- 21 -EH -TT W /(4) ' ' SV -205 FLUID COOLER IFC -1 MAKE UP WATER LINE FLOW CONTROL VALVE OPEN -CLOSE (7) 115 VAC 1 PH 66 PSIG MAX- DIFFERENTIAL PRESSURE (5) NELES - JAMESBURY 2 "- 4A- X- 22- 36 -TT -3 W /(6) SV -225 FLUID COOLER IFC -2 MAKE UP WATER LINE FLOW CONTROL VALVE OPEN -CLOSE ( 115 VAC 1 PH 66 PSIG MAX. DIFFERENTIAL PRESSURE (5) NELES - JAMESBURY 2 "- 4A- X- 22- 36 -TT -3 W /(6) SV -245 FLUID COOLER IFC -4 MAKE UP WATER LINE FLOW CONTROL VALVE OPEN -CLOSE 0 115 VAC 1 PH 66 PSIG MAX. DIFFERENTIAL PRESSURE (5) NELES - JAMESBURY 2 "- 4A-- X- 22- 36 -TT -3 W /(6) SV -265 FLUID COOLER IFC -3 MAKE UP WATER LINE FLOW CONTROL VALVE OPEN -CLOSE 0 115 VAC 1 PH 66 PSIG MAX. DIFFERENTIAL PRESSURE (5) NELES - JAMESBURY 2 "- 4A- X- 22- 36 -TT -3 W /(6) FLOW SWITCH SCHEDULE . DEVICE NUMBER LOCATION DEVICE FUNCTION SETPOINT RANGE CONTACT RATING ADDITIONAL PARAMETERS REMARKS MANUFACTURER /MODEL 4 PP/4-6,..40-q... ACTIVATE (GPM) DEACTIVATE (GPM) FS -004 ( MOTOR COOUNG HEAT EXCHANGER CWR LINE CWR WATER FLOW SWITCH 400 - -- 20' TO 120'F 115 VAC 1 PH CARBON STEEL CONNECTION, SS WETTED PARTS Q (1;(3) �XF10 D28 A GEMS SENSOR FS 26615. FS -014 WEST MOTOR BEARING HT EXCHR CWR UNE CWR WATER FLOW SWITCH 2.5 20' TO 120'F 115 VAC 1 PH CONTACTS CLOSE ON FALLING FLOW FS -024 ( EAST MOTOR BEARING HT EXCHR CWR LINE CWR WATER FLOW SWITCH 2.5 CWR WATER TEMP TRANSMITTER DIFFERENTIAL PRESSURE INDICATOR /TRANSMITTOR 115 VAC 1 PH CONTACTS CLOSE ON FALLING FLOW an GEMS SENSOR FS 26615 FS -034 / FAN SHAFT THRUST BEARING HT EXCHR CWR LINE CWR WATER FLOW SWITCH 10 CWR WATER TEMP TRANSMITTER 115 VAC 1 PH CONTACTS CLOSE ON FALLING FLOW (I X3) GEMS SENSOR FS -2 089 (SIZE 1-1 /2 FS -044 ' FAN SHAFT JOURNALBEARING HT EXCHR CWR LINE CWR WATER FLOW SWITCH 10 - -- 115 VAC 1 PH CONTACTS CLOSE ON FALLING FLOW 1 3 GEMS SENSOR FS -27089 (SIZE: 1 -1/2 ") FS -074 / LCI -1 HT EXCHR CWR LINE • CWR WATER FLOW SWITCH 110 -- 115 VAC 1 PH CARBON STEEL CONNECTION, SS WETTED PARTS (2) STATIC 0 RING 901- 24 -2 -2 FS -084 / LCI -2 HT EXCHR CWR LINE CWR WATER FLOW SWITCH 110 - -- 115 VAC 1 PH CARBON STEEL CONNECTION, SS WETTED PARTS C2) STATIC 0 RING 901- 24 -2 -2 TEMPERATURE TRANSMITTER SCHEDULE DEVICE NUMBER LOCATION DEVICE FUNCTION SETPOINT RANGE OUTPUT ADDITIONAL PARAMETERS REMARKS MANUFACTURER /MODEL ACTIVATE (GPM) DEACTIVATE (GPM) TT -001 / MOTOR COOUNG HEAT EXCHANGER CWR LINE CWR WATER TEMP TRANSMITTER DIFFERENTIAL PRESSURE INDICATOR /TRANSMITTOR 66 20' TO 120'F 4 -20 MA BRASS TEMPWELL (I X2) 7 C. S. GORDON#ARJBHOA024UJO05701J TT -011 ' WEST MOTOR BEARING HT EXCHR CWR LINE CWR WATER TEMP TRANSMITTER DIFFERENTIAL PRESSURE INDICATOR / TRANSMITTOR 20' TO 120'F 4 -20 MA BRASS TEMPWELL On C. S. GORDON#ARJBHOA024UJO05701 J TT -021 ' EAST MOTOR BEARING HT EXCHR CWR LINE CWR WATER TEMP TRANSMITTER DIFFERENTIAL PRESSURE INDICATOR /TRANSMITTOR 66 20' TO 120'F 4 -20 MA BRASS TEMPWELL 1 2 C. S. GORDON#ARJBHOA024UJO05701 J TT-031 ' FAN SHAFT THRUST BEARING HT EXCHR CWR LINE CWR WATER TEMP TRANSMITTER 20' TO 120'F 4 -20 MA BRASS TEMPWELL (i')(2) C. S. GORDON#ARJBHOA024UJO05701J TT- -041 ' FAN SHAFT JOURNALBEARING HT EXCHR CWR LINE CWR WATER TEMP TRANSMITTER 20' TO 1207 4 -20 MA BRASS TEMPWELL i 2 C. S. GORDON#ARJBHOA024UJO05701 J TT -071 • LCI-1 HT EXCHR CWR LINE CWR WATER TEMP TRANSMITTER 20' TO 1207 4 -20 MA BRASS TEMPWELL 1 2) C. S. GORDON#ARJBHOA024UJO05701 J TT-081 ' LCI -2 HT EXCHR CWR LINE CWR WATER TEMP TRANSMITTER 20' TO 1207 4 -20 MA BRASS TEM?WELL (1;(2) C. S. GORDON#ARJBHOA024UJO05701J TT -100 ' CWR NEAR AS -1 CWR WATER TEMP TRANSMITTER 20' TO 120'F 4 -20 MA BRASS TEMPWELL 1 C. S. GORDON#ARJBHOA024UJ005701J DIFFERENTIAL PRESSURE INDICATOR /SWITCH SCHEDULE DEVICE NUMBER LOCATION - DEVICE FUNCTION SETPOINT RANGE CONTACT RATING ADDITIONAL PARAMETERS REMARKS MANUFACTURER /MODEL ACTIVATE (PSIG) DEACTIVATE (PSIG) MANUFACTURER /MODEL PDT -121 COOLING WATER PUMP CWP -1 DIFFERENTIAL PRESSURE INDICATOR /TRANSMITTOR 66 -- 0 - 100 PSIG (1) BRASS HOUSING AND WETTED PARTS 2 3 ORANGE RESEARCH 1503 - DGS- 1- B- 2.5- L- 10- 100PSIG PDT -131 COOLING WATER PUMP CWP -2 DIFFERENTIAL PRESSURE INDICATOR / TRANSMITTOR 66 -- 0 - 100 PSIG (1) BRASS HOUSING AND WETTED PARTS (?f3) ORANGE RESEARCH 1503- DGS- 1- B- 2.5- L- 10- •100PSIG PDT -141 COOLING WATER PUMP CVCP -3 DIFFERENTIAL PRESSURE INDICATOR /TRANSMITTOR 66 -- 0 - 100 PSIG 0) BRASS HOUSING AND WETTED PARTS (2x3) ORANGE RESEARCH 1503- DGS- 1-- B- 2.5,- L- 10- 100PSIG HEAT TRACE SCHEDULE DEVICE NUMBER LOCATION DEVICE FUNCTION SETPOINT VOLTAGE CONTACT RATING ADDITIONAL PARAMETERS REMARKS MANUFACTURER /MODEL ACTIVATE (TEMP 'F) DEACTIVATE (TEMP 'F) HTS -001 FLOOR 1, COL J -21 TEMPERATURE MAINTENANCE 36 45 120 VAC 60 HZ 30 AMP NON VOLITILE MEMORY (Z22 RAYCHEM MONITRACE 1000 CONTROL MODULE HTS -002 FLOOR 1, COL J -21 FREEZE PROTECTION 36 45 120 VAC 60 HZ 30 AMP NON VOLITILE MEMORY (J RAYCHEM MONITRACE 1000 CONTROL MODULE SYM Cr ACCESSORIES_ TYPE "J" THERMOCOUPLE, 2 -1/2" INSERTION LENGTH WITH NEMA 4 JUNCTION BOX © TEMPWELL: C. S. GORDON #50 CS. MOUNT IN 3" TEE WITH 2' -0" APPROX STRAIGHT PIPE ON EITHER SIDE OF TEMPWELL. O ACCESSORIES: NEMA 4 JUNCTION BOX WITH 3 PIN TERMINAL BLOCK (RATED 24VDC) P/N 55633. © ACCESSORIES: NEMA 4 SWITCH HOUSING WITH 115 VAC /60HZ 15 AMP CONTACTS. 03 FURNISH WITH 100 MICRON FILTER. ® THIS IS A CUSTOM ENGINEERED ITEM. ORDER FROM ADS EQUIPT (STEVE AZOSE) QUOTE NO 06 -38 fFL?�' " 3t,oD 10 10 -A 115 VAC 60 HZ DPDT RELAY © BRACKET OR PIPE MOUNT SWITCH. (- ACCESSORIES: NEMA 4 ALUMINUM ENCLOSURE, WEATHER PROOFED, LIQUID FILLED GU AGE. ® VALVE: 150# FLG SIDE PORTED 3 -WAY VALVE, TFE SEATS & SEAL. O ACTUATOR: FOXBORO - JORDAN SM- 5220- E- S- K- 4- O- S- O- L- O- H- O -O -O -A WITH MOUNTING BRACKET. (1000 FT LB -30 SECOND ACTUATING TIME 115 VAC MOTOR DRIVEN ACTUATOR © VALVE: 150# LUG STYLE BUTTERFLY VALVE. DUCTILE IRON W TFE SEATS & SEALS. ® ACTUATOR: NELES - JAMESBURY EJ90 WITH MOUNTING BRACKET. (90 FT LB 115 VAC MOTOR DRIVEN) 05 VALVE: FULL PORT THREADED CARBON STEEL BALL VALVE WITH STAINLESS BALL & STEM, TEE SEATS & SEALS, & STAINLESS BOLTS & NUTS. ® ACTUATOR: NELES - JAMESBURY EJ20 WITH MOUNTING BRACKET. (20 FT LB 115 VAC MOTOR DRIVEN) Q PROVIDE 115 VAC CONTROL SWITCHING RELAY. 10 MOUNT TO WALL INSIDE BUILDING © DEVICE SHALL HAVE SOFT START FEATURE FOR LIMITING HEAT TAPE INITIAL AMPERAGE DRAW REVISION ANAL REVIEW UPDATE BY SEC APPROVED SEC DATE 4/18/96 REVISION APPROVED DATE oo 1 ® ®E - ZAW FACILITIES DEPARTMENT ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRA NY J S. CASSADY TAM. S. CASSADY CHECKED S. CASSADY APPROVED S. CASSADY J PRFMEY GATE 2 -14 -96 2 -14 -96 2 -14 -96 2 -14 -96 2 -21 -96 2 -21 -96 1AE SaT u l� e 2 yzo (T s , ‹�� 2,16r.2 (27015 i l /v6 £m•IP - 3bao SUBTITLE INSTRUMENTATION SCHEDULES 7I � 6 �./ ( �/ L � S I ; j� r �G � � I � ~D1V �I° tj ✓J P ee; C4.4.4 ,4 — (APTA' 1o6 - 543 RECEIVED CITV OF TUKWILA 1 l) I. ` r '1996 PERMIT CENTER TITLE AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II GENERAL NOTES: SHEET DWG NO. CITY Of TUKWILA APPROVED AUG 20 1996 BUILDING DIVISION Architects Engineers A: Planners UST REVISION JOB N0. M 1 V PL2 -94164 ■.I \1 2.83. M 1 c IATE 4/18/96 OF COMP N0. 7E CO ti 2" MU WATER TO IFC'S 3/4 "TO COOLING TOWER BASIN RENSION FINAL REVIEW UPDATE 10" COOLING SYSTEM M WATER FROM RPBP 4 NC 1 1 -1/2'FROM COOLING TOWER BASIN AUTO AIR VENT NC FCBP SEPARATOR DETAIL SCALE: NOT TO SCALE m AUTO AIR VENT EXPANSION TANK 3/ 3/4" 3/4" 14330 143 0 CWR FUNNEL DRAIN TO SANITARY v 10" I41ii rdall TT 001 TI 002 FS 004 • • • • • • TE 001 • • TI 003 AS TI 012 FS 014 • • • 6" r -CWR Atik CWS REVISION v MOTOR COOLING HEAT EXCHANGER 10" 0 APPROVED P.O.C. DATE 8 " 0" 10" 8 " 10" 0 0 0 0 0 0 6" 6" IFC MU -WATER S WEST MOTOR BEARING HEAT EXCHANGER 1 6' D4 0 FCV 230 0 CC 0 O > O T ® ®E /A/G FACILITIES DEPARTMENT 6 C41151 I 6 " P.O.C. > 8 " CWS 0 0 0 0 0 0 rj CWR 4. 1 " 4" C14 4" 4 C1J RAIN 4" CIV 4 " 4" 2" DRAIN CWS DQ D4 CWS Er — EAST MOTOR BEARING HEAT EXCHANGER T T CWR maws tom Bo I F UID COOLER PACKAGE 1 ,11i1 II 1 11 1 1 1 11 1 ! 1 11 1 1 1 ;11 11 II �J�I J - CI4 • 0 • IuL rmerrA—K •/\ ` \ °` °. L L �lJ1 F UID COOLER PACKAGE -1 11 1 1 ' 1 11 1 1 ° IIII / o ( III ! 111!1 X11 1— -J1 1 SV J \205 8 „ FCBP -2 FCBP- 1 EXPIRES B /]0/97 6" 6" rr qb.oq 0 D4 FCBP SEPARATOR SEE DETAIL 1 THIS SHEET (TYP 4 PL) 0 0 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION 0 APPROVED APPROVED BY DEPT DATE DUI v 4" 1 4" D <1 4" 4" CI11 2 " DRAIN D . 1 C CI 4 EffIllalrerAIIEZ ETSIL.NBEM 6 ,. 11IJ L L - - - = =_ =T- FLUID COOLER PACKAC , 11 1 1 1 1111 11 1 11 1 1 I 1 - - I 0 0 0 0 L L I FLUID COOLER _ PACKAGE 111 II o � o v IIII I I I I II 11 _ 1 JjPI1 _J Gi4 2" DRAIN C4 W W DUTTON 722 11 1 J 1 1 suBTTrTE C11 SV 245 FCBP -3 FCBP - 4 FLUID COOLER P&ID TI T I' AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II GENERAL NOTES: 1. THE FOLLOWING CONTROL SEQUENCES CAN BE FOUND ON M1 o: O COOLING SYSTEM CONTROL ALGORITHEM FOR FAN DRIVE SYSTEM. ALGORITHEM PROGRAMMED • INTO MOTOR PLC -CL. O INDUSTRIAL FLUID COOLER PACKAGED CONTROL PANEL ® FLUID COOLER BASIN PUMP SOLIDS SEPARATOR PACKAGE CONTROL PANEL ECEIVED CITV R OF TUKWIUI I. 1251 PERMIT CENTER 0 11 OF IU1SWI1 APPROVED AUG 2 0 1996 aUILDING DIVISION LAST REVISION SHEET M330 JOB N0. ■ - 1 Architects Engineers & Planners •YAIBOE DATE A 4/18/96 PL2-941 64 DWG NO 2.83.14330 OF COMP N0. ' REVISVDN FINAL REVIEW UPDATE H 8Y SEC APPROVED DATE SEC 4/18/96 REVISION L LCI- 1 (ABOVE) _J E LCI-2 (ABOVE) APPROVED 1 DATE L FIRST FLOOR PLAN SCALE: 1/4-= J i ArZW.461 FACILITIES DEPARTMENT u-c 100 1/2 CFM MOTOR ABOVE) UP . • : ! • z UP TO SECOND FLOOR ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE '07 CL SHAFT (ABOVE) .6; = w.wioluITTON S CASSADY S. CASSADY CHECKED S. CASSADY AP ROV S CASSADY A 11-22-95 1'1-22-95 11-22-95 11 -95 AY.PRTIFNEy 2-21-96 2-21-96 TITLE CH` •i 1 Ei 1995 PERMIT CENTER SUBTITLE HVAC DUCTWORK & EQUIP: FIRST FLOOR AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT 11 GENERAL NOTES: BLDG. 2.84-1 0i•IU 99° AUG 2 0 VISS n ■oso , KEY PLAN BLDG. 2.83 0 SCALE: NONE p r iMISI Architects Engineers PlAnners SYWBO UST REViSION SHEET M 450 JOB NO. PL2 -941 64 DWG NO. 2.83.M450 DATE 4/18/96 Of COMP NO. '!L ET 1 M451 M530 mqboo° I REVISfOH FINAL REVIEW UPDATE RPBP SEE /� -4' CWR EL 1 10' -3 1 /2" 4 "CWS - - - --T I ! N I C E 109' -3 1/ 4L; I M451 M530 LCI 1 (ABOVE) TRICAL DUCTBANK (ABOVE TYP) MOTOR(ABOVE) L_ BY SEC APPROVED SEC DATE 4/18/96 sY L1 L PRV SEE M451 12' -4" (REF) M - V H I 15' -3 5/15 ] 11 1 (TYP VERIFY IN rFED) REVISION BY A453 12' -4" (REF) APPROVED 3' -0" . 2' -8" IZL 12' -9" (REF) FIRST FLOOR PLAN SCALE: 1/4 "= 1'- FACILITIES DEPARTMENT 12' -5" (REF) 1" CWR WATER 2" MAKEUP WATER ) MATCHLINEI SEE DWG M535 1 EXIST 2 1/2" OW SERVICE e 12' -5 (REF) 18 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEFT. 12' -5" (REF) DATE DRAWN BY W. DUTTON S. CASSADY EFCR. S. CASSADY CHECKED S. CASSADY APPROVED S. CASSADY A P RF NEY 17 DI 22 =95 1'1 -22 -95 d - 22 -95 11 -22 -95 2 -21 -96 2 -21 -96 R RECOV RY Be (BY C CULEC; BRACK TO COLUMN WITH UNISTRUT. ROUTE DISCHARGE TO WATER LEVEL SENSOR. WATER LEVEL DETECTION CONNECTION ON LCI. PIPE FROM LCI CONNECTION TO WATER RECOVERY BOX OR WATER LEVEL SENSOR CONNECTION WITH 1/2" PIPE AS SHOWN ON DWG. ® WATER LEVEL SENSOR (BY CEDULEC). BRACKET TO COLUMN WITH UNISTRUT. ROUTE DISCHARGE TO FLOOR DRAIN u � FLANGE CONNECTION TO CEGELEC MOTOR 7 RECEIVED CITY OF TUKWILA 1 6 1996 PERMIT CENTER SUBTITLE FLUID :'COOLER PIPING PLAN: FIRST FLOOR GENERAL NOTES: 1:50 AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II L A- x- x- x- x -x -xJ BLDG. 2.84 - \ON KEY PLAN BLDG. 2.83 0 SCALE: NONE Architects Engineers I Planners DA LAST REASON A 4/18/96 SHEET M451 JOB N0. PL2 -94164 DWG NO 2.83. M451 OF CAMP NO. REVISION FINAL REVIEW UPDATE M BY SEC APPROVED SEC DATE 4/18/96 12' -4" (REF) SYM MOTOR ROOM: SECOND FLOOR SCALE: 1/4 "= 1' -0" REVISION BY 12 " -4" (REF) APPROVED CLWR AND C UNIT FROM E DATE WS TO LCI =LOW (TYP 2 PL) 12' -9" (REF) AF®E/A/G FACILITIES DEPARTMENT MATCHLINE SEE DWG M535 12 (REF) 12' -5" (REF) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 12' -5" (REF) M452 125' -1 1/4 -11 lippowN li C7) DRAN BY �7A7E W. W DUTTON T1 -22 -95 CHECKED S. CASSADY 11 -22 -95 S. CASSADY 11 -22 -95 CHECKED S. CASSADY 11 -22 -95 APPROVED S CASSADY 2 -21 -96 APPR V D J. E NEY 2 -21 -96 2' -I 1/8` 125' -1 1/4" TYP 3 PL) CL 125' -10 1/4" 126' -11 5/8" 122' -9 1/2" VERIFY IN HELD D' FLANGE CONNECTION TO CEGELEC MOTOR EQUIPMENT. THREADED CONNECTION TO CEGELEC EQUIPMENT. LOCATE VALVE STATION IN VERTICAL DROP. CABLE STAYED ELASTOMER EXPANSION JOINT. ® FLOW SWITCH FS -014 EL 124' -1 3/4" 0> FLOW SWITCH FS -004 EL 126' -11 5/8" © FLOW SWITCH FS -024 EL 124' -10 3/4" TEMPERATURE TRANSMITTER TT -001 CL EL 126' -1 1 5/8" ® TEMPERATURE TRANSMITTER 7-011 X, EL 124' -1 3/4" TEMPERATURE TRANSMITTER TT -021 C EL 124' -10 3/4" 2" PIPE DRAIN AT BOTTOM OF PIPE. FULL THREADED COUPLING WITH 4" NIPPLE AND BALL VALVE. 1" MANUAL AIR VE T AT TOP CENTER OF PIPE. INSTALL SIMILAR TO Lx- SUBTITLE FLUID'` COOLER PIPING: SECOND FLOOR GENERAL NOTES: ¶!T VIE= A BLDG. 2.84-1 KEY PLAN BLDG. 2.83 0 SCALE: NONE ECEIVED CITY R OF TUKWILA 1 6 1996 PERMIT CENTER Architects Engineers & P anners SYMBOL DATE uST REVISION 4/18/96 IT AERODYNAMICS LABORATORY sneer TRANSONIC WIND TUNNEL UPGRADES M 452 DF NO FAN DRIVE SYSTEM REPLACEMENT OB ND PL2 -94164 COMP COL H- J/17 -23 PLANT II OWE NO. 2.83.M452 INSTRUMENT PUMP NUMBER PIPE DIAMETER "D" STRAIGHT PATTERN PUMP DISCHARGE VALVE - TYP. (BALANCE, CHECK AND SHUTOFF.) FLAPPER STYLE FLOW INDICATING SIGHTGLASS FLOOR 3 1/2" GROUT PAD 3/1 3 DIA PIPE SUPPORT ON e 1/2" X 6"X 6" BASE. DRILL 4 5/8" HOLES ON 6" BOLT CIRCLE. BOLT TO CONCRETE WITH 1/2" CINCH ANCHOR, 3" MIN EMBEDMENT VERTICAL END SECTION PUMP DETAIL SCALE: NOT TO SCALE M 0 REMOVEABLE COUPON (TYP.) BALL VALVE (TYP.) CORROSION CUPON RACK SCALE: NOT TO SCALE mob ooq I M451 M530 PRESSURE GAUGE WITH - VIBRATION SNUBBER PUMP GATE VALVE FLEXIBLE PIPE CONNECTION (TYP) REDUCER (TYP.) -IF REO'D. SUCTION DIFFUSER WITH STRAINER Sc SUPPORT LEG \_4" HIGH CONCRETE HOUSEKEEPING PAD NOTE: ALL PIPING ACCESSORIES AND VALVES SHALL BE UNE SIZE. REFER TO PLANS FOR PIPE SIZES. BALANCE VALVE WITH MEMORY STOP -1/2' 3/4- 1" ASME PRESSURE RELIEF VALVE B & G 790 OR EQUAL. SET 80 PSIG PRESSURE REDUCING VALVE B & G OR EQUAL. SET 70 PSIG 1 " OH I RETURN LINE S---O CW MAKE -UP FROM REDUCED PRESSURE BACKFLOW PREVENTER (SEE DETAIL 6/M530) FLUID COOLER HO 3/4 "BLOW DOWN CONNECTION TERMINATE BLOWDOWN PIPE OVER FLOOR DRAIN 4" TALL CONCRETE HOUSEKEEPING PAD AUTO AIR VENT BALL VALVE (TYPh UNION (TrP)_ 1 FLUID COOLER MAKE UP AND WATER TREATMENT DIAGRAM SCALE: NOT TO SCALE M535(M530 1 0 1. 3/4" TERM "NATE DISCHARGE PIPE OVER FLOOR DRAIN AUTO AIR VENT TO PUMP SUCTION FLOOR BLADDER TYPE EXPANSION TANK AND AIR SEPARATOR DIAGRAM (T SCALE: NOT TO SCALE M451 M530 SUPPLY STRAINER MOUNT 12" OFF WALL , ■ ■� • :=2.11011. TO COOLING SYSTEM ■ MU WATER I t * ' WALL BRACKET (TYP.) U AIR GAP PIPE TO FLOOR DRAIN OR HUB DRAIN REDUCED PRESSURE BACKELO'W PREVENTER SCALE: NOT TO SCALE DOOM A/7919 REDUCED PRESSURE BACKFLOW PREVENTER W /SHUT OFF VALVES, WATTS 909 OR EQUAL. M451 M530 3/4" HOSE 81BB 3/4" BALL VALVE (TYP.) UNION (TYP.) SITE GLASS OR FLOW INDICATOR FUNNEL (MAX. 4' AVOVE FLOOR) 3/4" FILL AND VENT VALVE 3/4" N_ - FROM PUMP DV :J.:l-I, I''GE TO PUMP INTAKE CHEMICAL FEEDER PIPING DIAGRAM -- SCALE: NOT TO SCALE ASME PRESSURE RATED FOR FEEDER (5 GAL. MIN., GALVANIZED IRON) M45 M530 COOLER AND PIPING DETAILS RECEV IED CIT/ OF TUKWILA JIG. 1 1995 PERMIT CENTER '� AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II GENERAL NOTES: T EVAPORATIVE SPRAY PUMP DISCHARGE TO TOWER. (COMPLETE PIPE AND PUMP SYSTEM INCLUDED WITH INDUSTRIAL FLUID COOLER PACKAGES). MAKE UP WATER CONNECTION TO INDUSTRIAL FLUID COOLER T INDUSTRIAL FLUID COOLER ACCESS DOOR (INCLUDED WITH FLUID COOLER PACKAGE). E> EVAPORATIVE SPRAY PUMP INLET CONNECTION. T OVERFLOW DRAIN CONNECTION TO FLUID COOLER. I> INDUSTRIAL FLUID COOLER BASIN PUMP SEPARATOR INLET MANIFOLD. (SEE SEPARATOR SCHEDULE) 7> INDUSTRIAL FLUID COOLER DRAIN CONNECTION ® INDUSTRIAL FLUID COOLER BASIN PUMP SEPARATOR INLET CONNECTION (DOUBLE ENDED MPT) 9> MAKE -UP WATER BIOCIDE /ALGECIDE WATER TREATMENT CANISTER. BASIS OF DESIGN B.A.C. IOBIO 10 CORROSION CUPON RACK. SEE DETAIL 4/M530 E> INDUSTRIAL FLUID COOLER CONTROL PANEL. ED> INDUSTRIAL FLUID COOLER BASIN PUMP SEPARATOR DISCHARGE CONNECTION. FLEXIBLE CONNECTION (TYP) HANGER I I I FAN I iIIIIIIII`1 :1 Anon F1.�r I�I I I SPRING TYPICAL INLINE FAN NOT DETAIL MOTOR M450 M530 SUPPORT RODS AIR FLOW ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED ATP RF NEY 11 -22 -95 11 -22 -95 11 -22 -95 2 -21 -96 RMNSION FINAL REVIEW UPDATE 4/18/96 ® ®EOwc FACILITIES DEPARTMENT 2 -21 -96 SUBTITLE HNTB Architects Engineers & P tanners SYMBOL L AST REVISION SHEET 530 JOB N0, PL2 -94164 DWG N0. 2.83.M530 DATE 4/18/96 oP COUP NO. cw M535 M530 (REF) 3' -8 1 /4" 3' -8 1/4° 3'- M5[551 M540 SH•RT RADIUS ELL (REF) 13' -1 1" FLUID COOLER NOTE 6 (REF) 9' -6" FLUID COOLER NOTE 6 1 - Itt 1 -1/2 M535 M540 FLUID COOLER NOTE 6 (REF) 4' -10 1/4' 9 ° CLWR 6 "CLWS FLUID COOLER NOTE 6 (REF) FLEX CONNECTOR —� BREAK- AWAY — FLANGE ASSEMBLY --- 6 CLWS 6" CLWR -2T MAKEUP WATER. SEE NOTE 2. .FINAL REVIEW UPDATE M535 3' -0' 2' -8 eY SEC OPPROAD SEC 10 - -O' 2' -9° 6lb-009 1 MATCHLINE SEE OW 13' -9" 12' -5" ALL REDUCERS ON THESE UN TO BE FLAT ON BOTTOM M535 M540 )9 12' -5" 21' -4 1 /8" ®®E /A Ia FACILITIES DEPARTMENT M535 M540 12' -5" �2'-1 1 / 8' -6 3/8" FENCED AREA PLAN C/ SCALE: 1 /4°= 1 1 } A SHAFT A OVE AH 10' -11 1/2" 22' -9 3/4" WIND TUNNEL (ABOVE) '‘ 8' -0 3/4" ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 5' -2 3/4" DATE 13 -9' DNAW DATE W. DIYTTON v 11-22 -95 CHECKED S. CA 11 -22 -95 S . CASSADY 11 -22 -95 CHECKED . CASSADY I1 -22 -95 APPR OVED S. CASSADY 2 -21 -96 J NEY 2 -21 -96 13' -3 1/2" 10' -6" 6" IHORT RADIUS ELL (NF 4 ) 2" LOWPOINT DRAIN VANE (TYP 4) SUBTLE NORTH MECHANICAL AREA PLAN CRY OF 1 1161996 PERMIT CENTER TITLE AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT MECHANICAL MASTER COL PLANT II I HEAT TRACE AND INSULATE MAKEUP WATE LINE: 5 WATTS PER LINEAL FOOT. 1 HEAT TRACE AND INSULATE CWS AND CWI LINES OUTSIDE BUILDING TO MAINTAIN A TEMPERATURE OF NO LOWER THAN 40' F, ® INDUSTRIAL FLUID COOLER CONTROL PANE BOTTOM OF PANEL 3' -0 AFF. FLUID COOLER MAKE -UP AND WATER TREATMEN1 EQUIPMENT, SEE DETAIL 5 ON DWG M530 4 CONTRACTOR TO FURNISH HIGH POINT VENTS AND LOW POINT DRAINS AS REQUIRED. 4 PAIR OF CONTROLS CONTACTORS EXTENDED TO IFC CONTROL PANEL AND TERMINATED ON CONTACTS PROVIDED BY IFC MANUFACTURER. © SUPPORT FROM AS -1 PIPE SUPPORTS AND VALVE FLANGES. BLDG. 2.84 - KEY PLAN BLDG. 2.83 O SCALE: NONE SHEET GENERAL NOTES: TIN Of (UKWII- APPROVE AUG 20 1995 QI III WING; DIVISION Architects Engineers b P wens ,� UST RENSaN M535 4/1V5 JOB N0. COAy PL2 -94164 { avc NO 2.YD.M535 ` , TYP.HANGER SIZING GUIDE EQUIV. PIPE SIZE . PIPE SIZE THICKNESS OF PIPE INSULATION 1" 1 -1/2" 2" 4' 6' 7" 8" 6" 8" 10" 10" 8" 10" 12" 12' 10" 1 2 " 14" 14" 3/16"1/ EL 102' -0" ASSUMED PAVEMENT EL 99' -11" ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION 0 APPROVED APPROVED BY DEPT. DATE CH CASSADY APPROVED S CASSADY MEY 11 -22 -95 11 -22 -95 4/18/9 FACILITIES DEPARTMENT MIES 13/20/"7 W. DUTTON HANGER H -2 EL 108' -0 3/4" FENCE 3 - "/2° HIGH GROUT PAD ' SECTION AT AIR SEPARATOR M535 M540 :SCALE: 1/4" =1 - WP EL 109' -3 1 2" EL 110' -4 5/8" 109` -4 7/8" EL 108' -0 L 107' -9 3 L G' RED qL 105' -7 1/2" C BL 103' -8" 4 DIA PIPE SUPPORT ON Q 1/2" X gX 8" BASE. DRILL 4 5/8" HOLES ON 8" BOLT CIRCLE. /2° DIA "U' BOLT PIPE GUIDE. DOUBLE BOLT TOP AND BOTTOM OF STEEL TO GIVE 1/8" GAP ALL AROUND PIPE INSULATION (TYP ALL PIPES ON TOP OF STEEL IN ALL VIEWS) GRINNELL PIPE COVERING PROTECTION SADDLE OR 8 LONG INSULATION BLOCK. THICKNESS TO MATCH INSULATION ITHCCKNESS. GRINNELL FIG 159 OR EQ. (1Y1 ALL PIPES ON TOP OF STEEL IN ALL VIEWS) SUPPORT 2" AND UNDER PIPE LINES AT 1O' -0" SPACING. USE GRINNELL FIG 194 BRACKET. CINCH ANCHOR TO WALL. PIPE GUIDE AND SUPPORT DETAIL rr SCALE: 1/2" =1' -0" M540 M540 DRILL THRU PIPE SUPPORT AND DOUBLE NUT AS SHOWN SECTION AT THREE WAY VALVE (� SCALE: 1/4 " =1' -0" M535 M540 GRINNELL PIPE COVERING PROTECTION SADDLE FOR NOM. THK. OF COVERING: 1" -FIG. 160 1 -1/2" -FIG.. 161 2" -FIG. 162 2 -1 /2" -FIG. 163 3" -FIG. 164 4" -FIG. 165 PIPE HANGER H -2 SCALE: NOT TO SCALE SECTION AT FLUID COOLER ( SCALE: 1/4 " =1' -0" M535 M54O ROD LENGTH -FIELD DIM. GRINNELL FIG. 140/FIG.146 OR EQUAL.. SEE TABLE A FOR ROD SIZES_ CLEVIS HANGER GRINNELL FIG_ 260 M5401,1540 RACK PIPES ON WALL WITH UNISTRUT SECTION SCALE: 1/2 " =1' -0" EL 124'- 11 -5/8" c_ EL 123' -10 1/4" SECTION SCALE: 1 /4" =1' -0" b-10 "CLWS b-10 "CLWR --- ri BREAK AWAY FLANIF ASSEMBLY j} 8 "CLW BOP EL 110' -4 5/8" 2" CT WTR EL 109' -5 3/8' 8 CLWR --10 "CLWR -- 8" MOTOR CWS 1" E. MOTOR CWR 1" W. MOTOR CWR EL 124 EL 124' -1 3 4 SEC HON SCALE: 1/4 " =1' -0" M452IM540 M4521 M540 C EL 126' -11-5/8" C EL 125' -10 1/4" PIPE HANGER FOR 8" CWR. PIPE HANGER FOR 8 CWS 2 -21 -96 2 -21 -96 FLLX CUNNECIOR M535 M540 EL 124'- 11 -5/8" EL 123'- 10 -1/4" EL 108' -0 3/4" ??!?* ® x } RECEIVED CITY OF TWO, 1996 PERMIT CENTER SUBTITLE NORTH MECHANICAL AREA SECTIONS: nu AERODYNAMICS LABORATORY TRANSONIC WIND TUNNEL UPGRADES FAN DRIVE SYSTEM REPLACEMENT ECHANICAL MASTER COL PLANT II BLDG. 2.84 -1 xJ KEY PLAN BLDG. 2.83 Q SCALE: NONE Liana Architects Engineers B Ponners s A LAST REVISION SHEET M540 DWG NO PL2 -94164 2.YD.M540 ®ID MOE 4/18/96 COMP NO.