HomeMy WebLinkAboutPermit M96-0118 - MANNESMANN TALLYS110 1I9UA
IN - nV1
NIPv' WS3N1NI'dUUI
City of Tukwila
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
MECHANICAL PERMIT
Address: 1083 ANDOVER PK E
Location:
Parcel #: 262304 -9106
Contractor License No: MERITMI163CM
TENANT MANNESMANN TALLY
1083 ANDOVER PK E, TUKWILA, WA 98188
OWNER SECURITY CAPTIAL IND TRUST Phone: (206) 762 -4750
C/0 TRAMMEL CROW CO, PO BOX 80326, SEATTLE WA 98108
CONTRACTOR MERIT MECHANICAL INC. Phone: 206 883 -9224
9630 153RD AVENUE N.E., REDMOND, WA 98052
CONTACT STU ALLWORTH Phone: 206 883 -9224
9630 153RD AVENUE N.E., REDMOND, WA 98052
* * * * * * * * * * * * * * * * * * *, ************************ * * * * ** * * * * * ** * * * * * * * * ** * * * * ** **
Permit Description:
UMC Edition: 1994 Valuation:
Total Permit Fee:
******************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit No: M96 -0118
Type: B -MECH
Category: NRES
Permit Center Authorized Signature
INSTALL NEW 6 -TON HEAT PUMP AND TWO VVT ZONES AND
THREE BATH EXHAUST FANS.
C L - Dra - q ( V
Date
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All . provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this build p er t.
�
Signature:_ z I
Print Name:__,,,dla�/ Title:
Date : j .e.
(206) 4313670.
Status: ISSUED
Issued: 09/27/1996
Expires: 03/17/1997
9,400.00
114.75
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
Addres' .: 1083 ANDOVER Pi: E
Su ",itec
Tenant: MANNESMANN TALLY
Type.': B -MECH
Par # .: 262304 - 9106 ,
CITY OF TUKWILA
Permit No : M96,-0118
Status: ISSUED
Applied: 09/12/1996
Issued: 09/27/1996
k• k* k' k 4* * ** *•k *k * **** * **** * * *•k•k•k•k' * ***kk ** ******' k* kk** kk ***kkk *•k *•k *•k•k•kkkk *•k•k*
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Architect or Engineer and the Tukwila Building Division.
2. All permits, inspection' recor and approved plans shall be
available at the job site "prior to the start :of any Con -
struction, These :documentsare to be maintained and avail-
able until final 'inspection,.approval is granted.
3. All construction t.o `:be'.done An conformance with approved
plans and of the . Un itorm Building .`Code (1994
Edition) , is amended Uniform Mechanical Code (1994 Edition) ,
and Wash';i ngton State Energy Code (1994 Edit ion)
4. MANUFACTURERS INSTALLATION INSTRUCTIONS REOUIRED ON :
FOR THE INSPECTORS REVIEW..
5. HVAC:Systems shall be equipped with automatic controls capab .
le of�r.accomplishing a:;reduction. of energy use th rough. °contt:o
1 setback `or equipment.. shutdown durring periods of ,non-use or
al ter nat,e use of the spaces served by the system. The Autom
controls: shaI1 ; minimum, seven day clock and be ca
pable of being set .. for seven different day types per week.
WS'NRCC 141;2 4'
Duxcts not within conditioned. spaces On exterior of_.building,
on° roof";, in attic, in enclosed oe;ili ng space, in walls,,
cha,ll be" insulate'd'to min ;mum
7, Validity :, Permit sThe `issuance;' of ,a permit or approval
plans, 'speclfications, and computations "shat),not .becon-
strued to be a;permit tor, or an approval of, any violation .
of any of the provisions of the ; bu i 1 d'i ng ;_code; or of 'any
othe`rr'.Ordidance of the jurisdiction. No 'permit presuming,' to
give author i ty to ":violate or cancel .the`, provisions of this
code
Project Name/Tenant:
Value .f Construction:
Site Address: City State /Zip:
'^
Tax 'arcel Number:
- Z3O •• i .
Property Owner: _
YCO �Y ( At0) T 41. //IJ. ,61 )(7RtC 5 (/ US 7
_
Phone:
,S /O -ti/ - I/O?_-
Street Address: ,777,-- %A6fripA T 2 i4b City State /Zip:
Fax #:
Contact Person:
R) A /- L V) 0'R"f t•\
Phone:
. S _ C t Z Z y
Street Address: City State /Zip:
qip . 50 163('A Ave. 1\P fpramonc), Ric
Fax #:
Contractor:
PV. IZ VT MFC ii qN it-AL
Phone
2D - F' - c/2 2 2 /
Street Address: City State/Zip:
q ()_ D i S 21 /I\ IL` /di: 0 /1/14/5 #2 In1t 780 4
Fax #:
Architecj:
N R ARC 1\ \'TEL'f vl1 C C f b i)
Phone:
2bh - ' 2z.- 67r) n
Street Address: City State/Zip:
3s (AP3I:Lol.Jntki - r k1RKt.A.N)iv ii n Gi ?o3'
Fax #:
?a6 - 528 - /1/4
Phone:
Engineer:
Street Address: City State /Zip:
Fax #:
MISCELLANEOUS.PERMIT REVIEW AND' APPROVAL.REQUESTED: (to BE FILLED OUT BY APPLICANT)
- Description of work to be done:
),,8t/\) Ttw > wt-f cow? k z tint v ,ki� , fi 7) ,13/1/1-1 r x H - FAA ;
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ,ig- no
Attach list of materials and storage location on se.arate 8 1/2 X 11 •a•erindicatin• • uantities & Material Safet Data Sheets
■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead/Docks ■ Commercial Reroof
❑ ❑ Demolition ❑ Fence Temporary 171 Manufactured Housing - Replacement only
Parking Lots CI Retaining Walls Temporary Pedestrian Protection /Exit Systems
❑ Temporary Facilities ❑ Tree Cutting
MONTHLY SERVICE BiLLINGS,:TO ::::
. . .
Name:
Phone:
Address:
City /State /Zip:
0 Water
0 Sewer
0 Metro
0 Standby
CITY OF r 'KWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Miscellaneous Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
r
APPLICANT: REQUEST :FOR:MISCELLANEOUS.PUBLIC WORKS PERMITS : .:
❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s)•
❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading/clearing
❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Street Use ❑ Water Main Extension 0 Private 0 Public
Size(s): 0 Deduct 0 Water Only
Size(s)
Size(s): Est. quantity:
❑ Miscellaneous ❑ Moving Oversized Load/Hauling
❑ Channelization/Striping
❑ Flood Control Zone
❑ Landscape Irrigation
❑ Storm Drainage
❑ Water Meter /Exempt #
❑ Water Meter /Permanent #
❑ Water Meter Temp #
MISCPMT.DOC 7/11/96
gal
Schedule:
WATER METER DEPOSIT /REFUND BILLING:.
- Name:
Address:
Phone:
City /State /Zip:
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall
expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days
upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application
shall be extended more than once.
Date application accepted:
Date application expires:
Application 6 by: (initials)
BUILDING OWNER'OR AUTHORIZED AGENT:
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR
Above Ground Tanks/Water Tanks - Supported directly u pon grade
exceeding 5,000 gallons and a ratio of height to diameter or width
which exceeds 2:1
PERMIT REVIEW
Submit checklist No: M -9
Signature:
�• `\
(. -
Date:
6f/ 11
9
i n
Print name:
1 , ,.
��� ( Y 1 Q��.�
t7 �J
Pone: _ 7
Submit checklist No: M -6
Fax #:
Demolition
Address:
cu. Vie,
1.5 3 1W e 'fJ (=
Fences - Over 6 feet in Height
Ci y /State /Zip:,
K F: 17 atN 1/1
l,u )1 , C17 t
,c) -- 2 -
❑
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR
Above Ground Tanks/Water Tanks - Supported directly u pon grade
exceeding 5,000 gallons and a ratio of height to diameter or width
which exceeds 2:1
PERMIT REVIEW
Submit checklist No: M -9
in
Antennas /Satellite Dishes
Submit checklist: No: M -1
❑
Awnings /Canopies - No signage
Commercial Tenant Improvement
Permit
i n
Bulkhead/Dock
Submit Checklist No M -10
i n
i Commercial'Reroof.
Submit checklist No: M -6
❑
Demolition
'Submit checklist • " No :. M -3, M -3a.
❑
Fences - Over 6 feet in Height
Submit checklist No: M -9
❑
Land Altering/Grading/Preloads
Submit checklist No: M
❑
Loading Docks .
Commercial Tenant Improvement
Permit. Submit checklist No:.H -17
• Mechanical (Residential & Commercial)
'Submit checklist No. M -8,
Residential only - H -6, H -16
❑
Miscellaneous Public Works Permits
Submit checklist" No: H - 9
in
Manufactured Housing (RED INSIGNIA ONLY)
Submit checklist No: M -
❑
Moving Oversized Load /Hauling
Submit checklist No: M
in
Parking Lots
Submit checklist No: M -4
❑
Residential Reroof - Exempt with following exception: If roof structure
to be repaired or replaced
Residential Building Permit
Submit checklist No: M -6
❑
Retaining Walls - Over.4 feet in height
Submit checklist No: M-1'
❑
Temporary Facilities
Submit checklist No: M -7
❑
Temporary Pedestrian Protection/Exit Systems
Submit checklist No: M - 4
in
Tree Cutting
Submit checklist No: M -2
ALL MISCELLANEOUS P, - IT APPLICATIONS MUST BE SUB
ED WITH THE FOLLOWING:
> ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
• BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT
> STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON
LICENSED STRUCTURAL ENGINEER
> CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER
(P.E.)
❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
Bullding Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal,
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS
PERMIT.
MISCPMT.DOC 7/11/96
* hk** A***A k* k* k**h A* A h** k• k k* A** k k***k* k /a•k.% *A *A
I1Y OF TUIKWILA. WA c( kk - 1' �j A *kA ***kk* *A Akkkh * TRANSMIT
Ilk ** *Ak ** *k *k *A* *hdlk�4kk * M *kkA **4*
ek
TRANSMIT Number: 89600484 Amount: 114./5 09/27/96 10 :13
Payment Method: CHECK Notation: MERIT MECHANICAL Init: SLU
Permit No: M96 -0118 Type; L3-MECH MECHANICAL PERMIT
Parcel No: 262304 ^9106
Site Address: , 1983 'ANDOVER PK E
Total Fero:
This Payment 114.75 Total ALL Pmts:
ualunce:
114.75
114.75
.00
• k* AA*** A* * * **MA**k* *4A **AA *•hkA* *4** AAAAllA *AA+M1d *h *A * *A *AAA**
Account Code
000/345.83
000/322.100
Description
PLAN CHECK N0NRES
MECHANICAL - NONiRES
Amount
12.75
102.00
•
City of Tukwila
Fire Department
Address Ong 3 J� �
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor: /4
Pre -Fire:
Permits:
TuzWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name ( \ q/IA/ / &" 4! Ai/A/ 7' 'L c.
Vi--1
Retain current inspection schedule
eeds shift inspection
X Approved without correction notice
Approved with correction notice issued
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Permit No. /1 I q 6 o / / 6J
/-J w
/ 9
Authorized Signature Date
FINALAPP.FRM T.F.D. Form F.P. 85
Suite #
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 5754404 • Fax. (208) 57544439
ro ect:
Type of inspectio
PI I/1
ddress:
1 br5 tioVivii f'fc'e
Date called: ■ 1
Special instructions:
Date wanted: /o/ r i ,,
(4 ,
am.
Requester:
Phone No.:.-5( 4.
pproved per applicable codes,
INSPECTION RECORD
Retain a copy with permit
INSPECTI • N NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 70
COMMENTS:
re
Inspector:
Date: /t0O9(4,
I I
Corrections required prior to approval.
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
I Receipt No.:
Date:
Rrpj� �
a.Uws
Type of inspection
" `Y
Sp d�lr@s� o a,' f is E .
Date called: V A
a
ecial instructions:
3:00 plfi
Date wanted: 4:
Requester:
Phone No.:
33 ° i Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 9818
n Approved p,pr applicable codes. Corrections required prior to approval.
COMMENTS:
1� AO v sT r-ivt . cALaa`m.s ■cLr A 60
•'`rrO 4A NO .
(206) 431 -3670
Inspector: ( Date:
` �'r ; s l�s,Jti l b 3) 9t0
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection.
Receipt No.:
Date:
Ptpject: �
Gt tnt�
Type of ii pectin f M dbL1
��►
Addres :bg.
� 3 �►dov� P� � �
�
Date called: / b
� o r pi co
Special instructions:
41#°2416.
'O t h'1
Date wanted: /
1
($ I / �'
!
Requester:
Phone No.: ..cz /
O►rL
1 1
INSPECTION NO,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved ppr applicable codes.
INSPECTION RECORD
Retain a copy with permit
11
Date:
Molp b II T�
PERMIT NO,
(206) 431 -3670
CO MENTS:
Corrections required prior to approval;
Date :: f / 3/q,
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd„ Suite 100. CaII to schedule reinspection..
Receipt No.:
Project: ' v r ' D
0 +' .d �..4 +l..ti-+ .. L
)1'1 -w
Type of inspection:
.r' -).'1 ,tL.r_ r,, ,.., .i.-t"
Address: /I
4'.1 414-1 rr , eAr P...
(1,
Date called: �
Q
Special instructions:
.
Date wanted: /U /
/ 1
p.m.
Requester � a n
Phone No.: ��((
PFJ° 7 ��„r- •d/
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 9818
Approved ppr applicable codes.
Inspector:
I Receipt No.:
f
.lYr
PERMIT NO.
(206) 431 -3670
Corrections required prior to approval.
Date: / / /09../....9
$42.00 REINSPECTION EE REQUIRED. Prior to inspection, tee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:
COMMENTS:
Type of inspection:
N7 /.4- / is) .(..7`1t.,1:.V Aik,
f,-)/ c." C 4 / 3 t etri.... v I{_-- t•J i ini Ct•T" /c1 A ii I T.:
(;) .+-t1 I t .'-" (A1 n'4
. ia, rit tTfir-9 — • drj 6 1// 77 . 76
A i- ^!7, A.y or 714
1,N1 rt•iTi 1..10
T'ktzc"l
or 7Th S 14,;-)abiz-< ,
a to • / rJ eL,A -11 j - t.' .=o-
- pme t e'c't-I
c-»«1 /'.I'1., ,.
Ft •
Phone No.:
a
Project:
Type of inspection:
Address: ,.
Date called:
Special instructions:
Date wanted:
�� 6 '
7 / / /
a.m.
�p.m'7
Requester:
Phone No.:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206) 431 -3670
Corrections required prior to approval.
Inspector:
Date:
9 ,Vene
/
Ti $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
Project Info
Project Address MANNESMANN TALLY TI
Date 9/11/96
1083 ANDOVER EAST BUSINESS CENTER
For Building Dept. Use
TUKWILA, WA
Applicant Name: MERIT MECHANICAL
Applicant Address: 9630 153rd AVE NE, REDMOND, WA 98052
Applicant Phone: 883 -9224
Cooling Equipment Schedule
Equip.
ID
Brand Name'
Model No.
Capacity2
Btu /h
Total CFM
OSA CFM
or Econo?
SEER
or EER
IPLV3
Location
Fan Equipment Schedule
Equip.
ID
Brand Name'
Model No.1
CFM
SP
HP /BHP
Flow Controls
Location of Service
Equip.
ID
Heating
Equipment Schedule
Brand Name
Model No.
Capacity2
Btu /h
Total CFM
OSA cfm
or Econo?
Input Btuh
Output Btuh
Efficiency
Equip.
ID
1994 Wae- ' State Nonresidential Energy Code Compp ice Form
' lttanical.Su a,
mrn . J
1994 v /asnmgton State Nonresidential Energy Code Compliance Forms
. -4. 1
EFt ; NMECLr suM
June, 1995
Project Description INSTALLATION OF A 6 TON ROOFTOP HEATPUMP, 2 VVT ZONES
Briefly describe mechanical system AND THREE RESTROOM EXHAUST FANS (CEILING MOUNTED)'
type and features,
Compliance Option
0 Simple System 0 Complex System 0 Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.)
Equipment Schedules
The following information is required to be Incorporated with the mechanical equipment schedules on the
plans. For projects without plans, fill In the required information below.
1 1f available.
applicable.
5
2 As tested according to Table 14 -1, 14 -2 or 14 -3. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as
RECEIVED
CITY OF TUKWILA
SEP 1 2 1996
PERMIT CENTER
System Description
See Section 1421 for full description
of Simple System qualifications,
If Heating /Cooling
or Cooling Only:
0 Constant vol?
Split system?
0 Air cooled? X Packaged sys? M <54,000 Btuh
or 1900 cfm?
x Economizer Included?
If Heating Only:
<5000 cfm?
<70% outside air?
1994 Was ` Eton State Nonresidential Energy Code Compl
MechaniccatSurnma v (back)
'
MECHr -SUM
Decision Flowchart
Use this flowchart to determine if project qualifies for Simple System Option. If not, either the
Complex System or Systems Analysis Options must be used.
Start
System Type Ieating /Cooling
or cooling Uniy
' Reference
Sec, 1421
�ncluriA�
Econo
Included?
0
4,000 B
r 1900 cf
yes
ye
onsta
olume
Simple Syste
Allowed
Reference
Sec. 1420
n
Referenc 4,000 B
Sec. 1423 • r 1900 c
yes
r - le Form
Use Complex
System
(- Reference
Sec. 1430
Complex Systems
Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex
Systems requirements are applicable to this project.
Mechanical Permit P - s Checklt F • ;.: °T' �� .:naECFL -CHK
1994 Washington State Energy Corte Compliance Forms June, 1995
Project Address MANNESMANN TALLY TZ
Date 9/11/96
The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the
Washington State Nonresidential Energy Code.
'Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
HVAC REQUIREMENTS (Sections 1401 -1424)
1411
Equipment performance
yea
1411.4
Pkg. elec. htg.& clg.
List heat pumps on schedule
M-1
yea
1411.1
Minimum efficiency
Equipment schedule with type, capacity, efficiency
M -1
1412
HVAC controls
yea
1412.1
Temperature zones
Indicate locations on plans
M-1
1412.2
Deadband control
Indicate 5 degree deadband minimum
1412.3
Humidity control
Indicate humidistat
1412.4
Automatic setback
Indicate thermostat with night setback and 7 Jiff. day types
1412.4.1
Dampers
Indicate damper location and automatic controls
yea
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
M-1
1412.6
Combustion htg.
Indicate modulating or staged control
yee
1412.7
Balancing
Indicate balancing features on plans
M-1
1422
Thermostat interlock
Indicate thermostat interlock on plans
yea
1423
Economizers
Equipment schedule
M -1
1413
Air economizers
yea
1413.1
Operation
Indicate 100% capability on schedule
M-1
yee
1413.2
Control
Indicate controls able to evaluate outside air
24-1
yes
1413.3
Integrated operation
Indicate capability for partial cooling
24-1
1414
Ducting systems
yea
1414.1
Duct sealing
Indicate sealing necessary
code
yea
1414.2
Duct insulation
Indicate R -value of insulation on duct
code
1415.1
Piping insulation
Indicate R -value of insulation on piping
1424
Separate air sys.
Indicate separate systems on plans
Mech. Sum. Form
Completed and attached. Equipment schedule with types,
input/output, efficiency, cfm, hp, economizer
SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454)
1440
Service water htg.
1441
Elec. water heater
Indicate R -10 insulation under tank
1442
Shut -off controls
Indicate automatic shut -off
1450
Heated pools
1452
Pool water heaters
Indicate not electric resistance
1453
Pool heater controls
Indicate switch and 65 degree control
1454
Pool covers
Indicate vapor retardant cover
1454
Pools 90+ degrees
Indicate R -12 pool cover
1994 Wasp' Iton State Nonresidential Energy Code Compli -"ce Form
rcied for any ques provide explana
1994 Wasr -ton State Nonresidential Energy Code Comp li •e Form
Mechanical P"�'ri i "PI. Ch9cik1 :
1994 Washington Slate Energy Code Compiiance Forrns
�a u
EC tV K
June, 1995
Mechanical - General Requirements
1412 Controls
1412.1 Temperature Controls: Each system shall be provided with at
least one temperature control device. Each zone shall be controlled by
individual thermostatic controls responding to temperature within the zone.
At a minimum, each floor of a building shall be considered as a separate
zone.
1412.2 Deadband Controls: When used to control both comfort heating
and coding, zone thermostatic controls shall be capable of a deadband of at
least 5 degrees F within which the supply of heating and cooling energy to
the zone Is shut off or reduced to a minimum.
Exceptions:
1. Special occupancy, special usage, or code requirements where
deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, If in the proposed
building energy analysis, heating and coding
thermostat setpoints are set to the same temperature
between 70 degrees F and 75 degrees F Inclusive,
and assumed to be constant throughout the year.
3. Thermostats that require manual changeover between heating
and cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for
adding moisture, a humidistat shall be provided.
1412.4 Setback and Shut -Off: HVAC systems shall be equipped with
automatic controls capable of accomplishing a reduction of energy use
through control setback or equipment shutdown during periods of non -use
or altemate use of the spaces served by the system. The automatic controls
shall have a minimum seven -day clock and be capable of being set for
seven different day types per week.
Exceptions:
1. Systems serving areas which require continuous operation at the
same temperature setpolnt.
2. Equipment with full load demands of 2 kW (8,828 Btu/h) or less
may be controlled by readily accessible manual off -
hour controls.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets
serving conditioned spaces shall be equipped with dampers which close
automatically when the system is off or upon power failure. Stair shaft and
elevator shaft smoke relief openings shall be equipped with normally open
dampers. These dampers shall remain closed In normal operation until
activated by the fire alarm system or other approved smoke detection
system.
Exceptions:
1. Systems serving areas which require continuous operation.
2. Combustion air Intakes.
1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall Include
microprocessor controls that minimize supplemental heat usage during
start -up, set -up, and defrost conditions. These controls shall anticipate
need for heat and use compression heating as the first stage of heat.
Controls shall Indicate when supplemental heating Is being used through
visual means (e.g., LED Indicators).
1412.8 Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Btu/h shall have modulating or
staged combustion oontrol.
Exceptions:
1. Boilers.
2. Radiant Heaters.
1412.7 Balancing: Each air supply outlet or air or water terminal devise
shall have a means for balancing, including but not limited to, dampers,
temperature and pressure test connections and balancing valves.
1413 Air Economizers
1413,1 Operation: Air economizers shall be of automatically modulating
outside and return air dampers to provide 100 percent of the design supply
air as outside air to reduce or eliminate the need for mechanical cooling,
1413,2 Control: Air economizers shall be controlled by a control system
capable of determining if outside air can meet part or all of the building's
coding Toads,
1413.3 Integrated Operation: Building Heating Energy: Air
economizers shall be capable of providing partial cooling even when
additional mechanical cooling is required to meet the remainder of the
coding load. Controls shall not preclude the economizer operation when
mechanical cooling is required simultaneously.
Exception: Economizers on individual, direct expansion, coding
systems with capacities not greater than 75,000 Btu/h may
include controls that limit simultaneous operation of the
economizer and mechanical coding for the purpose of preventing
ice formation on cooling coils.
1414 Ducting Systems
1414.1 Sealing: Duct work which Is designed to operate at pressures
above 1/2 inch water column static pressure shall be sealed in accordance
with Standard RS-18. Extent of sealing required is as follows;
1. Static pressure: 1/2 inch to 2 inches; seal transverse joints.
2. Static pressure: 2 inches to 3 inches; seal all transverse Joints
and longitudinal seams,
3. Static pressure: above 3 Inches; seal all transverse joints,
longitudinal seams and duct wall penetrations.
1414.2 Insulation: Ducts and plenums that are constructed as part of the
building envelope shall meet the requirements of Chapter 13. Other ducts
and plenums shall be thermally Insulated per Table 14-5.
Exceptions:
1. Within the HVAC equipment.
2. Exhaust air ducts not subject to condensation.
3. Exposed ductwork within a space that serves that space only.
1416 Piping Systems
1416.1 insulation: Piping shall be thermally insulated in accordance with
Table 14-8.
Exception: Piping installed within unitary HVAC equipment
Water pipes outside the conditioned space shall be insulated In
accordance with Washington State Plumbing Code (WAC 51.28)
1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT)
1421 System Type: To qualify as a simple system, systems shall be one o
the following:
a. Jr A coded, constant volume packaged equipment, which provide
heating, cooling or both, and require only external
connection to duct work and energy services.
b. Air coded, constant volume split systems, which provide heating,
coding or both, with cooling capacity of 54,000 Btu/h
or less.
c. Heating only systems which have a capacity of less than 5,000
cfm or which have a minimum outside air supply of
less than 70 percent of the total air circulation.
All other systems shall comply with Sections 1430 through 1438.
1422 Controls: In addition to the control requirements In Section 1412,
where separate heating and cooling equipment serve the same temperature
zone, thermostats shall be interlocked to prevent simultaneous heating and
coding.
1423 Economizers: Economizers meeting the requirements of Section
1413 shall be installed on packaged roof top fan - coding units having a
supply capacity of greater than 1,900 cfm or a total coding capacity greater
than 54,000 Btu/h.
The total capacity of all units without economizers shall not exceed
240,000 Btu/h per building.
1424 Separate Air Distribution Systems: Zones with special process
temperature requirements and/or humidity requirements shall be served by
separate air distribution systems from those serving zones requiring only
comfort conditions.
SYSTEM ._.SING SUMMARY
System Name : Mannesmann Tally TI 09 -09 -96
Location : Seattle- Tacoma, Washington Block Load v2.12
Prepared By : MERIT MECHANICAL Page 1 of 2
. ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TABLE 1. SIZING DATA -- COOLING
Total coil load =
Sensible coil load =
Total zone sensible=
Supply temperature =
Supply air (actual)=
Supply air (std) _
Ventilation air =
Direct exhaust air =
Reheat required =
Floor area (sqft)
Overall U -value
Vent air CFM /sqft
Vent air CFM /person
Heating coil load =
Ventilation load =
Total zone load =
Ventilation airflow=
Supply airflow =
TABLE 3. INPUT DATA -- WEATHER
City
State
Data Source
Latitude
Elevation
SIZING SPECIFICATIONS
Supply
Ventilation
Exhaust
= Seattle- Tacoma
= Washington
= User Modified
47.5 deg.
= 386.0 ft
Zone Name: Man's Tally Tech 108
17,365 BTU /hr
15,785 BTU /hr
14,449 BTU /hr
, 55.0 F
678 CFM
• 669 CFM
121 CFM
• 121 CFM
0 BTU /hr
TABLE 2. SIZING DATA -- HEATING
11,803 BTU /hr
6,337 BTU /hr
5,466 BTU /hr
121 CFM
678 CFM
TABLE 4. INPUT DATA -- HVAC SYSTEM
System Type : Clg & Warm Air Htg
System Start 800
Duration 12 hrs
= 850 Total coil load =
= 0.069 Sensible coil load =
= 0.14 SQFT /Ton =
= 20.00 Cooling BTU /hr /sqft =
Cooling CFM /sqft =
,55.0 F
20.00 CFM /person
100 %
FAN
Configuration : Draw -Thru
Static Pressure : 0.60 in.
Load occurs Q Aug 1500
Outdoor Db /Wb = 83.0/ 65.0 F
Coil Conditions:
Entering, Db/Wb = 76.4/ 62.9 F
Leaving Db /Wb = 54.6/ 54.0 F
Apparatus dewpoint= 53.4 F
Bypass factor = 0.050
Resulting zone RH = 49.9
Heating BTU /hr /sqft =
Heating CFM /sqft =
Floor area (sqft) =
Overall U -value =
Vent air CFM /sqft =
Vent air CFM /person =
1.45 Ton
1.32 Ton
587.38
20.43
0.80
Summer dry -bulb = 83.0 F
Coincident wet -bulb= 65.0 F
Daily Range . = 22.0 F
Winter dry -bulb = 21.0 F
Atmos. Clear. Num. = 1.05
THERMOSTAT SETPOINTS
Cooling (Occ) 75.0 F
Cooling (Unocc) : 85.0 F
Heating 70.0 F
FACTORS
Coil Bypass : 10.0$0
Safety (Sens) 0
Safety (Latent) : 0 %
Heating Safety 0 %
RETURN AIR PLENUM : N
CIT
RECEIVED
S E P 1 2 1996
PERMIT CENTER
13.89
0.80
850
0.069
0.14
20.00
(- SYSTEM SIZING SUMMARY
System Name : Mannesmann Tally TI 09-09 -96
Location :Seattle- Tacoma, Washington Block Load v2.12
Prepared By : MERIT MECHANICAL Page 2 of 2
' ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TABLE 5. TOP TEN COOLING COIL LOADS
Time
1) Aug /1500
2) July /1500
3) June /1500
4) Aug /1400
5) July /1400
Sensible
Ton
TABLE 6. ZONE SIZING DATA
Zone Name
• Man's Tally, Tech 108
1.32
1.31
1.30
1.30
1.30
14,449
Total
Ton
1.45
1.44
1.44
1.43
1.43
Maximum Design
Cooling Airflow
Sensible Rate
(BTU /hr) (CFM)
Time
6) June /1400
7) July /1600
8) Aug /1600
9) June /1600
10) Sept /1500
Design
Time
678 @ Aug 1500
Sensible
Ton
1.28
1.29
1.29
1.27
1.27
Total
Ton
1.42
1.42
1.42
1.42
1.39
Maximum Design
Heating Flow
Load Rate
(BTU /hr) (CFM)
5,466
SYSTEM SIZING SUMMARY
System Name : Mannesmann Tally TI
09 -09 -96
Location : Seattle - Tacoma, Washington Block Load v2.12
. Prepared By : MERIT MECHANICAL Page 1 of 2
****************************************** * * * * * * * * * * * * * * * * ** * * * * * * * * * * * **
TABLE 1. SIZING DATA -- COOLING
Total coil load =
Sensible coil load =
Total zone sensible=
Supply temperature'=
Supply air (actual).
Supply air (std)
Ventilation air =
Direct exhaust air =
Reheat required =
Floor area (sqft)
Overall U -value
Vent air CFM /sqft
Vent air CFM /person
TABLE 2. SIZING DATA -- HEATING
Heating coil load =
Ventilation load =
Total zone load =
Ventilation airflow=
Supply airflow =
TABLE 3. INPUT DATA -- WEATHER
City
State
Data Source
Latitude
Elevation
= Seattle- Tacoma
= Washington
= User Modified
= 47.5 deg.
= 386.0 ft
31,199 BTU /hr
12,674 BTU /hr
18,525 BTU /hr
243 CFM
1,857 CFM
TABLE 4. INPUT DATA -- HVAC SYSTEM
FAN
Configuration : Draw -Thru
Static Pressure : 0.60 in.
System Type : Clg & Warm Air Htg
System Start 800
Duration 12 hrs
SIZING SPECIFICATIONS ,
Supptily ' 20.00 CFM /person
Exhaust 100
Zone Name: Man's Tally Offices
45,610 BTU /hr Load occurs @ Aug 1400
42,260 BTU /hr Outdoor Db /Wb = 82.3/ 64.8 F
39,546 BTU /hr Coil Conditions:
55.0 F Entering Db /Wb = 76.0/ 62.6 F
1,857 CFM Leaving Db /Wb = 54.6/ 54.0 F
' 1,831 CFM Apparatus dewpoint= 53.5 F
243 CFM Bypass factor = 0.050
243 CFM Resulting zone RH = 49.2
0 BTU /hr
1,700 Total coil load
0.118 Sensible coil load =
0.14 SQFT /Ton =
. 20.p0 Cooling BTU /hr /sqft =
Cooling CFM /sqft =
•
Heating BTU /hr /sqft =
Heating CFM /sqft
Floor area (sqft)
Overall U -value =
Vent air CFM /sqft =
Vent air CFM /person =
_
_
•
3.80 Ton
3.52 Ton
447.27
26.83
1.09
Summer dry -bulb = 83.0 F
Coincident wet -bulb= 65.0 F
Daily Range = 22.0 F
Winter dry -bulb = 21.0 F
Atmos. Clear. Num. = 1.05
18.35
1.09
1,700
0.118
0.14
20.00
THERMOSTAT SETPOINTS
Cooling (Occ) 75.0 F
Cooling (Unocc) 85.0 F
Heating 70.0 F
FACTORS
Coil Bypass :! 0.050
Safety (Sens) 0
Safety (Latent) : 0 %
Heating Safety 0 %
RETURN AIR PLENUM : N
USYSTEM SIZING SUMMARY
System Name : Mannesmann Tally TI 09 -09 -96
Location Seattle- Tacoma, Washington Block Load v2.12
Prepared By : MERIT MECHANICAL Page 2 of 2
****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TABLE 5. TOP TEN COOLING COIL LOADS
Zone Name
Time
1) Aug /1400
2Y July/1400
3 ).. Aug /1500
4> June /1400
5) July /1500
TABLE 6. ZONE SIZING DATA
Man's Tally Offices
Sensible
Ton
3.52
3.50
3.49
3.45
3.47
Maximum
Cooling
Sensible
(BTU /hr)
39,546
Total
Ton
3.80
3.78
3.77
3.75
3.74
Design
Airflow
Rate
(CFM)
Time
6) Aug /1300
7) June /1500
8) July /1300
9) June /1300
10) Sept /1400
Design
Time
1,857 @ Aug 1400 18,525
Sensible
Ton
3.44
3.41
3.43
3.38
3.17
Maximum
Heating
Load
(BTU /hr)
Total
Ton
3.71
3.71
3.70
3.68
3.63
Design
Flow
Rate
(CFM)
SEP-10-96 WED 17:23 SIERRA CONSTRUCTION FAX NO. 206 885 4330 P.03
Sent by:
r •
DAMATO CONVERSANO 2C( 75e8e 09/11/98 17:05 Job 315
uw .• umwiu V%IU 13
SEP.11 '96 4:50P1 CONVERSANO EWPETT n647521699
rsmsT 4-
4
DCI
D'AMATO
CONVERSANO
R.1 UM /Mtn
eXIST 2.1e4 1.4"0.
Htt.1.4 LhJii
op.) lot( °rot
Lints eoret4tue
14.A17f914,A21,4
uds4 soilo, et.
tifw bid of4vi,
144.10P41•4
rd '
lb.......
..1.••■■■
Pct. Name:
tiAt4i.155MeNt.1
Construction Field Sketch:
12.00F rn &AI Uorr
4 001Ttor3
EvIST Cb
P.3
RECEIVED
CITY OF TUKWILA
sEP 1 2 1996
PERMIT CENTER
Page 1/3
1
S5F-10-96 WED 17:24 SIERRA CONSTRUCTION FAX NO. 206 885 4330 P. 04
Sent by; DAMATO CONVERSANO 20 wee 09/11/96 17:06 1 ob 315
eill/v6; leAn; I ()AMATO CORKI5ANO1 117
SEP.11 '96 4:50PM DRMRTO CONYERSANO EVERETT 20625E1699
DC I
DAMATO
CONVERSANO
INC.
Consulting Envntcrs
forl WALL
Oevi get*
UV IT
r
eAtt,11110
tri a 1.14
Set
e a
( )r ur
'MP
61.4 ywe
6r't pot
_At. 6vt 1.41.1e
1•10.11.11
OF1961 Aga
S444tRAT It. f u1Lon4s1 fi..A0
Soate
P-40 F inecH 1101i'
11- 001 - no , si
s'e
94 C
(sr)
Pro). Nam=
rStialv #.1 TAL.LE17
Construction Field Sketch:
p.e
Eser. UAW.. •
Proj.
cf&I497
batcl
By; CAS
Sketch A:
FS I
Page 2/3
Fire Department Review (511)
Control #M96 -0118
Dear Sir:
t
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
9/25/96
Re: Mannesmann Tally - 1083 Andover Park East
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. H.V.A.C. units rated at greater than 2,000 cfm require
auto - shutdown devices. These devices shall be separately
zoned in the alarm panel and local U.L. central station
supervision is required. (City Ordinance #1742)
H.V.A.C. systems supplying air in excess of 2,000
cubic feet per minute to enclosed spaces within
buildings shall be equipped with an automatic shutoff.
Automatic shutoff shall be accomplished by
interrupting the power source of the air - moving
equipment upon detection of smoke in the main
supply -air duct served by such equipment. Smoke
detectors shall be labeled by an approved agency for
air -duct installation and shall be installed in
accordance with the manufacturer's installation
instructions. (UMC 608)
Remote indicator lights are required on all above
ceiling smoke detectors. (City Ordinance #1742)
The installation of wiring and equipment shall be in
accordance with N.F.P.A. 70, Article 760, Fire
Protective Signaling Systems. (NFPA 72 -1- 5.5.4)
When the control panel is located inside a room, the
door to the room shall have a sign with one -inch
letters which reads "Fire Alarm" or "Fire Alarm
Control ". (City Ordinance #1742)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phones (206) 575.4404 • Fax (206) 575 4439
City of Tukwila
Fire Department
Page number 2
2. Dedicated fire alarm system circuit breaker(s) shall
be equipped with a mechanical lockout device. (NFPA 72
(1- 5.2.8.2))
Thomas P. Keefe, Fire Chief
Duct smoke detectors shall be capable of being reset
from the alarm panel. (City Ordinance #1742)
3. In areas that are not continuously occupied, automatic
smoke detection shall be provided at each control unit(s)
location to provide notification of fire at that location.
(NFPA 1 -5.6)
4. All new fire alarm systems or modifications to
existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence
until a fire department permit has been obtained. (City
Ordinance #1742) (UFC 1001.3)
Contact The Tukwila Fire Prevention Bureau to witness all
required inspections and tests. (UFC 10.503) (City
Ordinance #1742)
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: File
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) S7S -44139
CU
CHD
0
Ecr
r1G
G
M
.R
vD
VR
YT
'EC
5
ST
SK
EA
IC
TO
TL
TOR
TRL
USp
v
YM
WI3D
WC
U
ER
&B
&G
G
IK,
1 IR
16
KBD
0
'OC
'0P
'0S
'OSL
'0w
P
. PO
�PH
IPTN
IS
IV
SEAT COVER DISPENSER'
SCHEDULE
SOAP DISPENSER OR
STORM DRAIN
SECTION
SQUARE FEET
SHEET
SHEATHING
SOLAR INSULATED
GLAZING
SIMILAR
SINK
SEALER
SANITARY NAPKIN
DISPENSER
SANITARY NAPKIN
RECEPTACLE
SEALANT
STANDPIPE
SPECIFICATION
SQUARE
SOLID SURFACING
STMNLFSS STEEL
SERVICE SINK
STONE/STONE TILE
STATION
SOUND TRANSMISSION
CLASS
STANDARD
STEEL
STORAGE
STRUCTURAL.
SUSPENDED
SHEET VINYL
SYMMETRICAL
SWITHCHDOARD
SPECIAL WALL COVERING
TREAD
TOWEL BAR
TERRAllO
TOP & BOTTOM
TONGUE & GROOVE
TEMPERED GLASS
THICK
THRESHOLD •
TEMPERED INSULATED
GLAZING
TACK BOARD
TOP OF
TOP OF CONCRETE
TOP OF PAVEMENT
TOP OF STEEL
TOP OF SUB
TOP OF WALL
TOWEL PIN
TOILET PAPER DISPENSER
TOILET PAPER HOLDER
TOILET PARTITION
TUBULAR STELA
TELEVISION
OWNER:
TENANT:
ARCHITECT:
r
Swaim. • • arolor.io+0• a!"
,,l„1,uui wuIlirl�nlwII
SHEET WHERE SECTION IS DRAWN
DETAIL
DETAIL IDENTIFICATION
SHEET WHERE DETAIL IS DRAWN
WALL SECTION (IDENTIFY ON ELEVATIONS)
SECTION IDENTIFICATION
SHEET WHERE SECTION IS DRAWN
PROJECT DIRECTORY
SECURITY CAPITAL INDUSTRIAL TRUST
47775 FREMONT BLVD.
FREMONT, CA 94538
MANNESMANN TALLY
1083 ANDOVER EAST BUSINESS CENTER
TUKWIIA, WA
CNA ARCHITECTURE GROUP
3500 CARILLON POINT
KIRKLAND, WA 98033
NsN
t
9
Contact:
Phone:
Fax:
Contact:
Phone:
Fax:
Contact:
Phone:
Fax:
TOP OF PAVEMENT
PROJECT NORTH
5
DENOTES CHANGE IN ® c
ELEVATION w
U u-
o
U
KURT FULLER
(510) 661 -4026
(510) 661 -4033
KATHRYN CRAFT
(206) 822 -6700
(206) 828 -9116
SITE PLAN •
.�..� •..wr.Yrrli 1ra � ,!Wrrr "•
LL
w w
D.
F.
G.
DEPARTMENT OF LABOR AND INDUSTRIES
THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A
I certify that this is a true and correct copy of an original license.
>L� f;-?e<<
Notary. Public for the State of
' residing in Redmond.
•
j- DETACH TO DISPLAY CERTIFICATE --;
. t_ DETACH TO DISPLAY CERTIFICATE _!
•
STATE OF WASHINGTON
CITY
SEP 2 7 igg
PERMIT CENTER
F625.052- 000 13.921
SYM
MAKE & MODEL
DESCRIPTION
CFM
ESP
OSA
COOLING
CAPACITY
SEER
HEATING
CAPACITY
COP
WEIGHT
ELECTRICAL
NOTES
AC -1
CARRIER 50TJ0007
ROOFTOP HEATPUMP
2450
0.25
364
68400
9.0
68400
3
750
460 -3 MCA =36.7 MOCP =40
12kw HTR /SMOKE DETECT. /ECONO
EF -1
BROAN 360
CEILING EXH FAN
80
0.25
15
120 -1 0.7 AMPS
RESTROOM
EF -2
BROAN 360
CEILING EXH FAN
80
0.25
15
120 -1 0.7 AMPS
RESTROOM
EF -3
BROAN 360
CEILING EXH FAN
80
0.25
15
120 -1 0.7 AMPS
RESTROOM
TECH 190
104
TECH
103
1
295
295
275
1 0 "0
--> N
111 b- 0 16
TECH
105
12 "0
EQUIPMENT SC —EDULE
210
\/
/\
295
16 "0
10 "0
10 "0
\/
/ \
OFFICE 240
102
10 "0
ME
1
— VAC LAYOUT
SCALE: 1 /A" —1 ' _n"
J' LL. i —i —V
1 10 "
6 "0
WOM
107
12"
MEN
109
X 10 "0
20 x 1
10"0 10 "0 DUCT
EFr -3 THRU ROOF
16'0
10 "0!
EF -2 -
\
TECH
108
230
230
10 "0
1
14 "0 BYPASS DUCT AND DAMPER
: 1 TYPICAL OF TWO. SLAVED
TOGETHER.
* SYSTEM TO BE uARRIER PARKER VVT WITH
TWO 16"r S/A DAMPERS AND TWO 14 "0
BYPASS DAMPERS.
* INSTALL VOLUME DAMPERS ON EACH
SUPPLY AIR DIFFUSER TAKE —OFF.
* HVAC UNIT SCREENING BY OTHERS IF REQ'D
BY THE CITY OF TUKWILA.
* SUPPLY AIR DIFFUSERS TO BE SHOEMAKER 104P.
RETURN AIR GRILLES TO BE SHOEMAKER 105P.
* VERIFY T —STAT LOCATIONS WITH OWNER.
TAX ID #: 262304- 9106 -3
vices
STE . N
FILE COPY
I understend that the Plan Chec'c c ; cro
sub ;ect to errors and onduons and c� _:_I of
plans does not Whoa, OS *Solon of my
adopted cods or aim Nwelpt of contractors
copy er
BY av
t> ItN.. mgc0 —oA
REVISIONS
NO CHANGES SHALL BE MAr)E TO
THE SCOPE OF WORK WITHOUT PRIOR
APPROVAL OF TUKWILA BUILDING DIVISI ^V.
NOTE: REV ,,, WILL r,J,RE A NEW PL,1
AND rJ.
RECEIVED
CITV OF TUKWILA
SEP 1 2 1996
PERMIT CENTER
HEFEI MECHANICAL dr ew.
P.O. Dos 8395
Redmond, WA 98078-3395
(808) 383 -8184
L1081438. hauematescm
REVISIONS
DWAwPI VD
CHECKED
DATE
.0O0 NO.
SWOT
NUMBER
A
m
to
0
9 -10 -96
96090
DIM. MANE
MANNESM1.DWG