HomeMy WebLinkAboutPermit M96-0158 - OPASs.j ObW Ale r 7c2:u. City of Tukwila L Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M96 -0158 Type: B -MECH Category: NRES Address: 3325 S 116 ST Location: Parcel #: 092304 -9068 Contractor License No: UMC Edition: 1994 Signature:_ Print Name: .44'rlt2 / /.) / /04 -s .( MECHANICAL PERMIT INSTALLATION OF THREE (3) ROOFTOP MOUNTED UNITS. Valuation: Total Permit Fee: (206) 431 -3670 Status: ISSUED Issued: 11/26/1996 Expires: 05/25/1997 TENANT OPAS 3325 S 116 ST, TUKWILA WA 98168 OWNER SEAGATE /GATEWAY NORTH PROP C/O KEMPER R/E MGMT PO BOX 1459, LAFAYETTE CA CONTACT CRAIG RANDALL Phone: 203 241 -7784 1420 NW GILMAN BL #2121, ISSAQUAH WA 98027 *********************************, r********** * * * ** * * *** * * * * * ** ** ** * * **** * * ** Permit Description: 15,000.00 73.44 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** tbck -(t) -ef(p Perms Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit. does not presume to give authority to violate or cancel, the provisions of any other state or local laws regulating construction or :the performance of work. I am authorized to sign for and obtain this build 'g permit. Date: 6' Title: c {/17/Je t'r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 3325 S 116 ST Suite: Tenant: OPAS Type: B-MECH Parcel #: 092304-9068 CITY OF TUKWILA Permit No: M96-0158 Status: ISSUED Applied: 11/15/1996 Issued: 11/26/1996 ******************************************************A*k*****.****%**** Permit Conditions: 1. No changes will be made to the plans unless approved •by the Architect or Engineer and TuKwila Building Division. ,., _ -, 2. All permits, inspection: records, and plans shall be .. . , available at thejob:::Site'Orior to the any con- struction. These document are to,-:be maintained and avail- able until final 'inpeofjon ',approval is granted-, 3. All construction to be done )n:ConformanceWith approved plans and,,,reOuirementt of the Uniform Building Code U994 , Edition) as amended,'UniforM Mechant'eal.Code and Washington State EnergyCode (1994 Edition) , 4. Validity of Permit The issuance of a permit.or,approvel..of _. plansspecificattOns, and computations shall not be con strue0obe a permit for, or an approval of, any violation of any of the provisions of *ne:boilding code or of any,, other ordinance of the jurisdiction : No permit presuming to give authority toyi6late-oryoancet :the provisionsof,this code shall be valid 5. MANOFACT7RS::INSTALLATIONJNSTFUCTIONS REQUIRED ON ,SITE FOW)THE_BUILDIWINSPECTORV REVIEW 6, Plumbing permits Oall be!obtained through;the Seattle7King CoOty7DepartMent_of Plumbing will be 'iniOcted piping (29'644722) 7. EleriOa),..0e0pits shall be obtained through the WS11.ingeon StatiADivilOn-,of Labor and IndustrIeS' and .all electrical ,,- worOolf,Win4ected by that agen6y'(248-6610).. • Project Want: Value of Consu /tiny: o00.00 Site Address: � City State/Zi : 3 Gv , /1 �-r� +l 5* 7 O? - /C/ 11/ , di GAB Tax Parcel Numbe c 2 c:, — 9acocb Property Owner Phone: Stre Address: City State /Zip: , a,�)e .' `? G-4, r6 9' Fax #: Contac Person: .��/C- r1 46� •- S7/ZdPUZ-i �ext/,C Phone: , Street Address: City State/Zip: 7 n N/ , 6/41• ,e54vo �a1 � pAl iO4. ' & &7. Fax #: �y1 Contr ctor: I /sJ t T L I Li Lie: t A4-1 t iL (0 . Phone: �� .,. - 7 yv7- Street Address: City State/Zip: 1 420 hl /mil , 61 L,r� - I/#J L LVP I al . 1 Fax #: ce-/1 _7Ze.S — Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS.PERMIT.REVIEW' AND. APPROVALREQUESTED:: BE,FILLED'OUTBYAPPLICANT) Description of work to be don t 3) 126 FTOI u Ns iTS • _ Will there be storage of flammable /combustible hazardous material in the building? ❑ yesno Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes ❑ Bulkhead /Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO:: Name: Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby Miscellaneous Permit Application APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelizatlon /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s : Est. quantity: gal Schedule: ❑ Miscellaneous DJ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: Address: MISCPMT.DOC 7/11/96 CITY OFD UKWILA Permit Cente' 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Phone: City /State /Zip: CITY OF TUKWILA Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This igure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. N p y 1 5 1996 Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not excgNAall upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: " 9C, Date application expires: 5 . " - — - 7 Appllcallon taken by: (Initials) BUILDING OWNER OR AUTHORIZED AGENT: SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist. No: M -9 • Signature:(,,, f J% ❑ Awnings /Canopies - No signage Date: "(47 Print name: G,c, Bulkhead/Dock /A1, /a4 `� ❑ Commercial Reroof Pho _// �7 f Fax # ��� -7zg' Address . /5`�a</,/2 Submit checklist No M-3, M -3a V ��av, iai,� - iri' Cry /State /Zip: / .� � J. 'O4 ., g Z7— 7ao ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PERMIT REVIEW Submit checklist. No: M -9 • ❑ Antennas /Satellite Dishes Submit checklist;' No: M -1 ❑ Awnings /Canopies - No signage Commercial Tenant Improvement Permit ❑ Bulkhead/Dock Submit checklist No M -10 ': ❑ Commercial Reroof Submit checklist No M -6 ❑ Demolition Submit checklist No M-3, M -3a ❑ Fences - Over 6 feetin Height Submit checklist No: ' M -9 ❑ Land Altering/Grading /Preloads Submit checklist No: M -2 ❑ Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 ❑ Mechanical (Residential & Commercial) Submit checklist No M -8, Residential only = H -6, H -16 ❑ Miscellaneous Public Works Permits Submit checklist ` No H -9 ❑ Manufactured Housing (RED INSIGNIA ONLY): Submit checklist No: M -5 ❑ Moving Oversized Load/Hauling Submit checklist No: M -5 ❑ Parking Lots Submit checklist No: M -4 ❑ Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist '. No: M -6 ❑ Retaining Walls- 4 feet in height Submit checklist . No M -1 ❑ Temporary Facilities Submit checklist No: M -7 ❑ Temporary Pedestrian Protection/Exit'Systems.: Submit checklist . No: M -4 ❑ Tree Cutting Submit checklist . No: M -2 ALL MISCELLANEOUS PE ' 'IT APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 RECEIVED CITY OF TUKWILA NOV 1 5 1996 PERMIT CENTER Account'Code 000/345.4330 000/322.100 Description .PLAN CHECK -• NbNRES MECHANICAL - NONRES k**hk **hk * **.k *.hh. ** *•h** / .ckk*******A* * *;t**Ik ****h* *•h•h:4 *** ***Alh TTY OF TUKWILA. W sF TRANSMIT * * *Ahh ** ** *. * ** r* * ** *** * * * *k• h * * * ** * *A *k * * * * ** * * *•k * * * * * *h ** TRANSMIT Number: R9600514 Amount: 73.44 11/26/9 12 «56 Payment, Method: CHECK Notation« STRAIGHTLINE Xn•it« SMC Permit No «, M96 -0158 Type H -MECH MECHANICAL PERMIT Parcel NW O!.92304-90,t8 • Site Address.:' 3325 S 116 ST Total Fees: 73.44 This Payment 73.44 Total ALL Pmts: 73.44 Balance: .00 ** * *A * * * *A A * * ** ***A **A ******A *•h *•h *AA* * * •k * *•*AA* fir * *At **•h** *A *** Amount 14.63 'ime Authorized Signatuie Needs shift inspection City of Tukwila Fire Department Thomas P. Keefe, Fire Chief TUKW/LA FIRE DEPARTMENT FINAL APPROVAL FORM Poj ect Name S Address 3 5 / ( Retain current inspection schedule Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: A / )1< /- / W) c Pre-Fire: Permits: Y Approved without correction notice Approved with correction notice issued ;:f :1^••• ,7- •&fig 7 Date FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Permit No . /P - Suite # / /27 /13 p/I r c I / Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57541404 • Fax (206) 5754439 ProJect: Type of inspepi6n. 1 ... t d.gy. � S 1 ST Date called: 2 _3 - 1 Special instructions: p IA I el I ,e 10 �q �vl : 30. Date wanted .... 1.4_Ci m. p.m. Requester, � IrOub(i` j o.: o�i7, - 214,4 INSPECTION RECORD a copy with permit Ihl to - 0{ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COTV1MENTS: I INSPECTION NO. Correction s..required prior to approval. Date: 2 � $42.00 REINSPECTION FEE ' REQUIRED. Prior to ins ec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: __(206 -3670 Date: Prt ptpct s eof nspecti n �j ca) ''] Address: Date called: s pecial instructions: '1l ife `'"H i / A j`I nn Gv� 15 -- O o'.-7 Date wante �: / � . a.m. Re : Request q t neNo.9 . " L f INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 COMMENTS: Approved per applicable codes. rrections required prior to approval. Inspector: Date: r I, c7 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: Project: 0 p Type of inspection Address n J / q Date called: / Special instructions: Date wanted: L4,A4, / } / � Q (a r a _` p.m. Requester: Phone No.: Approved per applicable codes. required prior to approval. I 1 Corrections COMMENTS: A INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Inspector: INSPECTION RECORD Retain a copy with permit (206) 431 -3670 Date: $42.00 REINSPECTION FE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Cooling Equipment Schedule Equip. ID Name' Model No.' Capacity' Total CFM OSA CFM Econo SEE,g7 or EER IPLV' Location `Kiu - , Brand G/1 I ?, J ° =4' - x..//,/77, rrx'/ eval ,f (O,iJO /0,0 --- A,1-. At'%f.. mu---1 i1 /7/ . mo, , -1 7 „/. /,2o &35 /0,0 ---- -, , .r2 f -io- . 375 •4 /TJ/i a /'tar✓ / l 0 4 / 0,0 -- 2.1 croi� 5 / lc �QtreatrJ /, Ze/A,/ /� /l1 1 ,.%,::-/' ,0,4 '`' l',0 ' , �77 I . i 17 7°Y /G Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM , SP' HP /BHP Flow Control Location of Service t T7 i . 462/ 1 •// ' - _ ' � - � r ; / 7 $ •A " & i s - i v , 1 1 1 5 Kid .1/214 Z z S 4t'' t � ;'.1 At'%f.. `' / 75 , /J " • /t77Ai S /� %�, (f-' -! � /,) / . � / 1' . 375 ",'/5i'' /2F-x-�'. %�r .C..24, AY- / JA, r, / ,, 5 / lc �QtreatrJ /, Ze/A,/ /� /l1 1 ,.%,::-/' ,0,4 '`' l',0 ' , �77 I . i 17 7°Y /G Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity' Total CFM OSA cfm Econo Input Btuh Output Btuh Efficiency' Applicant Namee, Z / /4 .- / ✓/ / / //rig /!//4 ., • Applicant Address:/ ;, _ Applicant Phone: e;, 2 4 ?. i Project Info Project Address �,,� l ^ / / /�, "a.r j.k .9'769.-y //' Date •-- �' j4 : , • l J,/,‘)) '?,/ , 5 For Building Department Use RECEIVED CITY OF TUKWILA NOV 1 9 1996 PERMIT CENTER Applicant Namee, Z / /4 .- / ✓/ / / //rig /!//4 ., • Applicant Address:/ ;, _ Applicant Phone: e;, 2 4 ?. i 1994 Washin.k n State Nonresidential Ener• Code..Com•liance Form Mechanical Summa, '994 Washington Stale Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. MECH -SUM April 1994 ,( //"•le) 1 S/ Lz -* ;Ccr 7r /.' / )y' jT g: A. /I, Compliance Option aSimple System ❑ Complex System ❑ Systems Analysis (See Decision Flowchart (over) for qualifications) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. ' As tested according to Table 14-1, 14-2 or 14-3. ' If required. ' COP, HSPF, Combustion Efficiency, or AFUE, as applicable. S Flow control types: VAV, constant volume, or variable speed. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: *Constant vol? ❑ Split system? gi Air cooled? , Packaged sys? CI <54,000 BM? ❑ Economizer Included? If Heating Only: y ❑ <5000 cfm? ❑ <70% outside air? 1994 Washin • t• State Nonresidential Ener Code com • Iiance Form Mechanical Summar' .' back) • MECH =SUM 1994 Washington State Nonresidential Energy Code Compliance Forms Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. tart System T yp e oeCool g Heating lOny '000 cfm r yes no <; <70% OA': --->~ N Yes n ,/ Reference Sec. 1421 no x54,000 BtuA' n`o r 1900 cfmY yes Includes Econo?) yes 'Constanh, �"`•-.Volume ? -n yes Cooled?.• ' no yes Reference Sec. 1423 Package. S n_ o ( Reference Sec. 1420 a: Split `System? no yes`' 54,000 Btu r 1900 cfm ye s . no ram macntrmr t?.xtrnrNA1V Apnl, 1994 Reference) Sec. 1430 Complex Systems Refer to MECH•COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. . . • . Mechanical Permit P ns Checklist . • MECH-CHK 1994 Washington State Energy Code Compliance Forms Apt!! 1994 • Project Address (2'A.) e-- i 1 (At S4 ' V1 1 I Vie-- . 011 . rate) f ) The following information is necessary to check a mechanical permit for compliance with the mechanical requirements In the Washington State Nonresidential Energy Code. Applicability L (circle one) J Code Section Component ,Information Required Location on Plans Building Department Notes HVAC RE OIREM NTS (Sections 1401-1424) 1411 Eqpmt performance yes no n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes no ma. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1412 HVAC controls yes no n.a. 1412.1 Temperature zones Indicate locations on plans yes no n.a. 1412.2 Deadband control Indicate 5 degree deadband minimum yes no n.a. 1412.3 Humidity control Indicate humidistat yes no ma. 1412.4 Automatic setback Indicate thermostat with night setback and 7 different day types yes no n.a. 1412.4.1 Dampers Indicate damper location and automatic controls yes no n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule yes no n.a. 1412.6 Combustion htg. Indicate modulatinfl or staged control yes no n.a. 1412.7 Balancing Indicate balancing features on plans yes no n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes no n.a. 1423 Economizers Equipment schedule 1413 Air economizers yes no n.a. 1413.1 Operation Indicate 100% capability on schedule yes no n.a. 1413.2 Control Indicate controls able to evaluate outside air yes no n.a. 1413.3 Integrated operation Indicate capability for partial cooling_ 1414 Ducting systems yes no n.a. 1414.1 Duct sealing Indicate sealing necessary yes no ma. 1414.2 Duct insulation Indicate R-value of insulation on duct yes no n.a. 1415.1 Piping insulation Indicate R-value of insulation on piping yes no n.a. 1424 Separate air sys. Indicate separate systems on plans yes no Mech. Sum, Form Completed and attached. Equipment schedule with types, In efficiency, cfm, hp, economizer SERVICE HATER HEATING AND HE ED PODLS (Sections 1440-1454) 1440 Service water ht yes no n.a. 1441 Elec. water heater Indicate R-10 Insulation under tank yes no n.a. 1442 Shut-off controls Indicate automatic shut-off 1450 Heated pools .. yes no n.a. 1452 Pool water heaters Indicate not electric resistance yes no n.a. 1453 Pool healer controls Indicate switch and 65 degree control yes no n.a. 1454 Pool covers Indicate vapor retardant cover yes no n.a. 1454 Pools 90+ degrees Indicate R-12 pool cover If "no" is circled for any auestion. provide explanation: •liai4111-C riti 1i1li-,.U..^;li,,S W ,` ; it i friii i V e g rA T . , i 1 VEA : F. 8.1 * 17,17,1 ; (1i .V•:* (4, ac t l - :::.v.i r aspiclirv i c ort mrcislinoper e Nsire="ther =rn ethieeS111ranerffaieesooir,virien,rinn.ir.r,w ri enecrosseripmsino,cycree resein ienicrenctscatsycieri&e, leyes 1994 Washingtp ,State Nonresidential Energy Code Compliance Form t • Mechanical - General Requirements 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall bo considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system Is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall bo equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. 'Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (8,826 Btu /h) or less may be controlled by readily accessible manual off- hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shalt and elevator shaft smoke relief openings shall be equipped with normally open dampers. Those dampers shall remain closed in normal operation until activated by the fire alarm system or other approved smoke detection system Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.5 Heal Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). • 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall bo controlled by a control system . capable of determining if outside air can meet pail or all of the building's cooling loads. 1994 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit P s Checklist 1994 Washington State Energy Code Compliance Forms MECH -CHK April 1994 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load, Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75.000 Btu /h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall bo sealed in accordance with Standard RS -18 Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches: seal transverse joints 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches: seal all transverse joints, longitudinal seams and duct wall penetrations. 1414.2 Insulation: Ducts and plenums that are constructed as part of the building envelope shall meet the requirements of Chapter 13. Other ducts and plenums shall be thermally insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1416 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14.6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall bo insulated in accordance with Washington State Plumbing Code (WAC 51.26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: a. Air cooled, constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. b. Air cooled, constant volume split systems, which provide heating, cooling or both, with cooling capacity of 54,000 Btu/h or less. c. Heating only systems which have a capacity of loss than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shall comply with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements in Section 1412, where separate heating and cooling equipment serve the same temperature zone, thermostats shall be interlocked to prevent simultaneous heating and cooling. 1423 Economizers: Economizers meeting the requirements of Section 1413 shall be Installed on packaged roof top fan - cooling units having a supply capacity of greater than 1,000 cfm or a total cooling capacity greater than 54,000 Btu /h. The total capacity of all units without economizers shall not exceed 240,000 Btu /h per building. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. CONSULTING ENGINEERS 1605 12TH AVENUE • SUITE 18 SEATTLE. WASHINGTON 98122 206'324-6160 NOV 87 '96 16:51 HUDSON AND ASSOC I / | ' ! '('- 7 '-----'-1 l «�el __'_ �� / __�_____�� { � . | , | � ! i i . | | i | j___1...... / - ' ' ' -- | V —.� _- ' | ' ' i ' [_ | ' w�� ^ '—'' —'--'—^—' —' --- -—�"=��—'« ! -- i '����� . � .- . / > � r ~�—`—L \— — � -~�� � � � � | | ~�~~ ) ! T ' —� 1 — —' ' — ' — --' '-�''- | / | | L : : :tr : :...::'' :: L_.1t ' i j / / � ' • �- ' � | - - / ! m* �� ��� �» Ww m * 6 `''~x�-'�-�- -*�-+ '- - r`- ``- ',---' . / . / | \ \ -- -k-' i - � '' ^—'-'-'^ ^~'` ---'-. I--�-'� -�---''---- -/� '--f-'� ' ~'�~''--!� | ( ) � | | / ' | / ' | | / / / ` ' / � ( . . . | | / | / ! . | , ---- ' | ' - "- -^'--1 | ' ��-' - ' - [_ | | _ � | ( .� [_ | | | . i --- -�-- ' - r ' — �- ` - - | / | 1 . � � ' . / ^�~—'[` �—~- F ' '-- r '`--'�— L | i -' --�-- / | 1 i i / 996 / . . ..-_ � | / / . . . | 1 -.. ......... - U -- � ! • - -'f-- | | | . '� | | / . . ' �� JOB `~�0��� SHEET NO CALCULATED BY u� ^� . | / [' �--- - / / ~_`--_---- , OF DATE P.2 ^} /'� ^��~ ^ ' I o�w -L -| __ | | ! ! | | [ -'� � / � ' } | � | | 1 —� —+--^—�{—� >' —� - � ' � ' | . / ! | | � n / / / ' ' / ' / / ' . / . � . . ` � � _,...... '-- ---+---�-^ ' _ '-� '�� ! 1 _. 1 ' —'+ -` 8 � \ | i � . � ' �������@�b �—� | ( | -—|� ----' U . ' / | | � ' , �F� /��� �mw��w���� / / . / / / ' t.r.:Wc",t17.t.tasiiSii;O:0,1atni 41421: r • • TABLE 1. DESIGN PARAMETERS .,........+..,.. w,.. u.».. orx.... e.. v+= ek. Awa..»«t. rww. ow. w. ,.+vw.«.r,.�..,....«........... WEATHER PARAMETERS City Name : TUKWILA 11 -14 -96 Location : WASHINGTON Block Load v2.03 Prepared By: STRAIGHTLINE MECHANICAL Page 1 of 2 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** City Name TUKWILA Location WASHINGTON Latitude 47.5 deg Elevation 97.0 ft Summer Design Dry Bulb Temp 83.0 F Summer Coincident Wet Bulb Temp 67.0 F Daily Temperature Range 13.0 F Winter Design Dry Bulb Temp 23.0 F Atmospheric Clearness Number 1.05 TABLE 2. MAXIMUM DAILY SOLAR HEAT GAINS (BTU /hr /sqft) Month Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec NE E SE S SW W NW N Hor 16.1 126.7 229.5 258.2 229.5 126.7 16.1 16.1 92.7 38.9 177.9 255.0 262.6 255.0 177.9 38.9 21.4 147.7 85.1 215.4 250.7 238.5 250.7 215.4 85.1 27.2 200.0 139.5 230.0 225.5 193.4 225.5 230.0 139.5 33.1 239.1 166.3 229.4 200.2 155.6 200.2 229.4 166.3 37.3 260.5 174.0 225.7 187.6 138.3 187.6 225.7 174.0 48.9 266.1 164.1 225.0 195.6 151.5 195.6 225.0 164.1 38.6 258.0 134.7 221.8 217.5 187.2 217.5 221.8 134.7 34.9 235.5 76.8 201.4 239.0 230.2 239.0 201.4 76.8 28.3 193.3 37.8 170.6 245.6 253.9 245.6 170.6 37.8 22.2 145.5 16.5 123.7 224.8 253.6 224.8 123.7 16.5 16.5 92.7 13.8 97.3 207.5 246.7 207.5 97.3 13.8 13.8 71.0 ticuo-ots RECEIVED CITY OF TUKWILA NOV 1 9 1996 PERMIT CENTER Hr January 000 51.8/ 50.0 100 50.9/ 49.5 200 49.9/ 49.1 300 49.2/ 48.7 400 48.6/ 48.1 500 48.4/ 47.9 600 48.8/ 48.3 700 49.7/ 49.0 800 51.4/ 49.8 900 53.9/ 50.9 1000 56.8/ 52.1 1100 60.0/ 53.4 1200 63.0/ 54.7 1300 65.3/ 55.6 1400 66.8/ 56.2 1500 67.4/ 56.4 1600 66.8/ 56.2 1700 65.5/ 55.7 1800 63.4/ 54.8 1900 60.9/ 53.8 2000 58.5/ 52.8 2100 56.4/ 51.9 2200 54.5/ 51.1 2300 53.0/ 50.5 Hr July 000 67.4/ 60.7 100 66.5/ 60.4 200 65.5/ 60.1 300 64.8/ 59.8 400 64.2/ 59.6 500 64.0/ 59.5 600 64.4/ 59.6 700 65.3/ 60.0 800 67.0/ 60.6 900 69.5/ 61.5 1000 72.4/ 62.5 1100 75.6/ 63.6 1200 78.6/ 64.6 1300 80.9/ 65.3 1400 82.4/ 65.8 1500 83.0/ 66.0 1600 82.4/ 65.8 1700 81.1/ 65.4 1800 79.0/ 64.7 1900 76.5/ 63.9 2000 74.1/ 63.1 2100 72.0/ 62.3 2200 70.1/ 61.7 2300 68.6/ 61.2 August WEATHER PARAMETERS City Name : TUKWILA 11 -14 -96 Location : WASHINGTON Block Load v2.03 Prepared By: STRAIGHTLINE MECHANICAL Page 2 of 2 ****************************************** * * * * * * * * * * ** * * * * * ** * * * * ** * * ** ** TABLE 3. COOLING DESIGN TEMPERATURE PROFILES (DB /WB in F) February 53.8/ 51.3 52.9/ 50.9 51.9/ 50.5 51.2/ 50.2 50.6/ 49.9 50.4/ 49.8 50.8/ 50.0 51.7/ 50.4 53.4/ 51.2 55.9/ 52.2 58.8/ 53.4 62.0/ 54.7 65.0/ 55.9 67.3/ 56.8 68.8/ 57.4 69.4/ 57.6 68.8/ 57.4 67.5/ 56.9 65.4/ 56.1 62.9/ 55.1 60.5/ 54.1 58.4/ 53.2 56.5/ 52.4 55.0/ 51.8 67.4/ 60.7 66.5/ 60.4 65.5/ 60.1 64.8/ 59.8 64.2/ 59.6 64.0/ 59.5 64.4/ 59.6 65.3/ 60.0 67.0/ 60.6 69.5/ 61.5 72.4/ 62.5 75.6/ 63.6 78.6/ 64.6 80.9/ 65.3 82.4/ 65.8 83.0/ 66.0 82.4/ 65.8 81.1/ 65.4 79.0/ 64.7 76.5/ 63.9 74.1/ 63.1 72.0/ 62.3 70.1/ 61.7 68.6/ 61.2 March 58.0/ 55.8 57.1/ 55.4 56.1/ 55.1 55.4/ 54.8 54.8/ 54.3 54.6/ 54.1 55.0/ 54.5 55.9/ 55.0 57.6/ 55.7 60.1/ 56.6 63.0/ 57.7 66.2/ 58.9 69.2/ 60.0 71.5/ 60.9 73.0/ 61.4 73.6/ 61.6 73.0/ 61.4 71.7/ 60.9 69.6/ 60.2 67.1/ 59.3 64.7/ 58.4 62.6/ 57.6 60.7/ 56.9 59.2/ 56.3 September 65.4/ 59.6 64.5/ 59.3 63.5/ 58.9 62.8/ 58.6 62.2/ 58.4 62.0/ 58.4 62.4/ 58.5 63.3/ 58.9 65.0/ 59.5 67.5/ 60.4 70.4/ 61.4 73.6/ 62.5 76.6/ 63.6 78.9/ 64.3 80.4/ 64.8 81.0/ 65.0 80.4/ 64.8 79.1/ 64.4 77.0/ 63.7 74.5/ 62.8 72.1/ 62.0 70.0/ 61.3 68.1/ 60.6 66.6/ 60.0 April 60.2/ 57.2 59.3/ 56.8 58.3/ 56.4 57.6/ 56.1 57.0/ 55.9 56.8/ 55.8 57.2/ 56.0 58.1/ 56.4 59.8/ 57.0 62.3/ 58.0 65.2/ 59.0 68.4/ 60.2 71.4/ 61.3 73.7/ 62.1 75.2/ 62.6 75.8/ 62.8 75.2/ 62.6 73.9/ 62.1 71.8/ 61.4 69.3/ 60.6 66.9/ 59.7 64.8/ 58.9 62.9/ 58.2 61.4/ 57.6 October 62.2/ 57.4 61.3/ 57.0 60.3/ 56.7 59.6/ 56.4 59.0/ 56.1 58.8/ 56.1 59.2/ 56.2 60.1/ 56.6 61.8/ 57.3 64.3/ 58.2 67.2/ 59.2 70.4/ 60.4 73.4/ 61.5 75.7/ 62.3 77.2/ 62.8 77.8/ 63.0 77.2/ 62.8 75.9/ 62.4 73.8/ 61.6 71.3/ 60.7 68.9/ 59.9 66.8/ 59.1 64.9/ 58.4 63.4/ 57.8 May 64.2/ 58.5 63.3/ 58.1 62.3/ 57.8 61.6/ 57.5 61.0/ 57.3 60.8/ 57.2 61.2/ 57.4 62.1/ 57.7 63.8/ 58.4 66.3/ 59.3 69.2/ 60.3 72.4/ 61.5 75.4/ 62.5 77.7/ 63.3 79.2/ 63.8 79.8/ 64.0 79.2/ 63.8 77.9/ 63.4 75.8/ 62.7 73.3/ 61.8 70.9/ 60.9 68.8/ 60.2 66.9/ 59.5 65.4/ 58.9 November 57.0/ 54.9 56.1/ 54.5 55.1/ 54.2 54.4/ 53.8 53.8/ 53.3 53.6/ 53.1 54.0/ 53.5 54.9/ 54.1 56.6/ 54.8 59.1/ 55.7 62.0/ 56.9 65.2/ 58.1 68.2/ 59.2 70.5/ 60.1 72.0/ 60.6 72.6/ 60.8 72.0/ 60.6 70.7/ 60.1 68.6/ 59.4 66.1/ 58.5 63.7/ 57.5 61.6/ 56.7 59.7/ 56.0 58.2/ 55.4 June December 52.8/ 52.2 51.9/ 51.4 50.9/ 50.4 50.2/ 49.7 49.6/ 49.1 49.4/ 48.9 49.8/ 49.3 50.7/ 50.2 52.4/ 51.9 54.9/ 53.1 57.8/ 54.3 61.0/ 55.6 64.0/ 56.7 66.3/ 57.6 67.8/ 58.2 68.4/ .58.4 67.8/ 58.2 66.5/ 57.7 64.4/ 56.9 61.9/ 55.9 59.5/ 55.0 57.4/ 54.1 55.5/ 53.3 54.0/ 52.7 66.4/ 60.7 65.5/ 60.4 64.5/ 60.1 63.8/ 59.7 63.2/ 59.6 63.0/ 59.5 63.4/ 59.6 64.3/ 60.0 66.0/ 60.6 68.5/ 61.5 71.4/ 62.5 74.6/ 63.6 77.6/ 64.6 79.9/ 65.3 81.4/ 65.8 82.0/ 66.0 81.4/ 65.8 80.1/ 65.4 78.0/ 64.7 75.5/ 63.9 73.1/ 63.1 71.0/ 62.4 69.1/ 61.7 67.6/ 61.1 HVAC SYSTEM DATA FOR OPAS RTU -1 Prepared By: STRAIGHTLINE MECHANICAL 11 -14 -96 Block Load v2.03 Page 1 of 1 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Table 1. HVAC SYSTEM DESCRIPTION System Type : Clg & Warm Air Htg System Start 700 Duration 10 hrs SIZING SPECIFICATIONS Supply • Ventilation Exhaust FAN Configuration : Draw -Thru Static Pressure : 0.00 in.wg. Table 2. SYSTEM ZONING INFORMATION System Arrangement: Each zone Total Zones Selected: 1 Selected Zones: 144 OPAS RTU -1 57.0 F 20.00 CFM /person 0 CFM THERMOSTAT SETPOINTS Cooling (0cc) Cooling (Unocc) Heating FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety • • • • RETURN AIR PLENUM : served by separate air handler 75.0 85.0 72.0 CITY OF NOV 191999 PERMIT CENTER F F F 0.050 0 0 % 0 l N GENERAL ZONE DATA Floor Area 1935.0 sqft Building Weight: M Exposures : N, E, S, W Are Multiple Wall, Roof, or Glass Types Used ? N No. Partitions : 1 LIGHTING W/sqft • 1.20 W /sqft Unocc Diversity: 0 % Wattage Mult. 1.25 Fixture Type : Rec., Not Vented OTHER ELECTRIC W /sqft 0.00 W /sqft Unocc Diversity: 0 W U -Value (BTU /hr /sqft /F) Weight (lb /sqft) Color EXTERNAL SHADING DATA Window Height Window Width = Reveal Depth PARTITIONS C Exposure ZONE NAME = OPAS RTU -1 0.050 L L 8.0 ft 4.0 ft 0.0 in WALL I ROOF x.. y. k ,u Imi,m,y,¢mttx re:iv aunwrsoror mworr tottlawkrAVrIAzi t'?MITI MRMh'�1F!ASXL",Y; Ve. 0.030 L D ZONE DESCRIPTION FOR OPAS RTU -1 Prepared By : STRAIGHTLINE MECHANICAL 11 -14 -96 Block Load Program v2.03 Page 1 of 1 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. GENERAL ZONE DATA PEOPLE sqft /person 130.0 sqft /per Unocc Diversity: 0 9 Activity Level : Office Work Sensible Gain 245.0 BTU /hr /per Latent Gain 205.0 BTU /hr /per MISCELLANEOUS LOADS Sensible 0 BTU /hr Latent • 0 BTU /hr Unocc Diversity: 0 % INFILTRATION Cooling 0.05 CFM/sqft Heating 0.10 CFM /sqft SLAB Area 1935 sqft Perimeter 43 ft Depth 0.50 ft ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 2. WALL, ROOF AND GLASS DATA Overhang Height Overhang Extension Fin Separation Fin Extension Gross Area Glass Area (sqft) (sqft) Partition Partition Type 1 Type 2 GLASS U -Value Glass Factor Int. Shades ? E Wall 0.0 0.0 S Wall 430.0 387.0 W Wall 0.0 0.0 N Wall 0.0 0.0 Roof (Hor) 1,935.0 0.0 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 3. PARTITION DATA Partition Type 3 0.650 0.75 N 0.0 in 0.0 in 0.0 in 0.0 in Net Area (sqft) 430.0 NA NA U -Value (BTU /hr /sqft /F) 0.050 NA NA Adj. Region Temp (Cooling) 83.0 F NA, NA Adj. Region Temp (Heating) 50.0 F NA NA ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Load Component Total Zone Loads Solar Loads Wall Transmission Roof Transmission Glass Transmission Skylight Transmission Partitions Lighting Other Electric People Infiltration Miscellaneous Slab Pulldown /Warm -up Safety Factor Ventilation Load Supply Fan Load Plenum Load Thru Wall Plenum Load Thru Roof Plenum Load - Lights Reheat Load TABLE 2. WALL AND GLASS BREAKDOWN Component Walls : NE E SE S SW W NW N Glass : NE E SE S SW W NW N !;.1d ';'gh tIMICM/ PAPr i,.c>sitarrm njrAyt altmtFwxn rftt,arrn Details 387 sqft 43 sqft 1,935 sqft 387 sqft 0 sqft 430 sqft 1.20 W /sqft 0.00 W /sqft 15 people 1,935 sqft 0/ 0/ 0 % 298 CFM 2,367 CFM 0 % 0 % 0 0 Zone. Name: OPAS RTU -1 1•tfF7.it Total Coil Loads 47,588 nr,asv.xnsant�anv DETAILED SYSTEM LOAD REPORT System Name : OPAS RTU -1 11 -14 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 1 of 1 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. LOAD COMPONENT SUMMARY for Sept 1400 ( 80.4/ 64.8 F) Design Cooling Loads Sensible Latent (BTU /hr) (BTU /hr) 31,326 60 2,534 516 0 172 7,803 0 2,685 3,051 562 -134 0 0 199 0 0 45,858 2,918 1,730 -412 0 0 0 0 0 Design Heating (BTU /hr) 105 2,844 12,326 0 473 10,204 1,875 0 27,829 15,699 2,506 43,528 Total Cooling Cooling Heating Net Area Transmission Solar Load Transmission (sqft) (BTU /hr) (BTU /hr) (BTU /hr) 0 0 - 0 0 0 - 0 0 0 - 0 43 60 - 105 0 0 - 0 0 0 - 0 0 0 - 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 387 516 31,326 12,326 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 mnru�rew�nr.wra 4Yr• "�tfe _.... r...,. ....:aiaiti?�: i.�.., =.G.: IrS'�i,c...'�4�z;'r1�45��. ;t�rsl TABLE 1. SIZING DATA Total coil load = Sensible coil load = Total zone sensible= Supply temperature = Supply air (actual)= Supply air (std) _ Ventilation air = Direct exhaust air = Reheat required = Floor area (sqft) Overall U -value Vent air CFM /sqft Vent air CFM /person TABLE 2. SIZING DATA -- HEATING Heating coil load = Ventilation load = Total zone load = Ventilation airflow= Supply airflow = City State Data Source Latitude Elevation TABLE 3. INPUT DATA -- WEATHER = TUKWILA = WASHINGTON = User Modified = 47.5 deg. = 97.0 ft "r".4 %. , "e731;! " " +t'4taTR7. p:V 7. SYSTEM SIZING SUMMARY System Name : OPAS RTU -1 11 -14 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 1 of 2 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Zone Name: OPAS RTU -1 -- COOLING 50,094 BTU /hr 47,588 BTU /hr 45,858 BTU /hr 57.0 F 2,367 CFM 2,359 CFM 298 CFM 0 CFM 0 BTU /hr 1,935 0.132 0.15 20.00 43,528 BTU /hr 15,699 BTU /hr 27,829 BTU /hr 298 CFM 2,367 CFM TABLE 4. INPUT DATA -- HVAC SYSTEM System Type : Clg & Warm Air Htg System Start 700 Duration 10 hrs SIZING SPECIFICATIONS Supply Ventilation Exhaust FAN Configuration : Draw -Thru Static Pressure : 0.00 in. 57.0 F 20.00 CFM /person 0 CFM . ".Dlittfl�err emvr..' .rs.,•roanvr.:a,nre.*e+..�«we.wrr nM*vrVZtJ 4a+rn '' kt4SlW" ,w,,w Load, occurs © Sept 1400 Outdoor Db /Wb = 80.4/ 64.8 F Coil Conditions: Entering Db /Wb = 75.7/ 63.6 F Leaving Db /Wb = 57.0/ 56.4 F Apparatus dewpoint= 56.0 F Bypass factor = 0.050 Resulting zone RH = 53.1 % Total coil load = Sensible coil load = SQFT /Ton = Cooling BTU /hr /sqft = Cooling CFM /sqft = Heating BTU /hr /sqft = Heating CFM /sqft = Floor area (sqft) = Overall U -value = Vent air CFM /sqft = Vent air CFM /person = 4.17 Ton 3.97 Ton 463.53 25.89 1.22 Summer dry -bulb = 83.0 F Coincident wet -bulb= 67.0 F Daily Range = 13.0 F Winter dry -bulb = 23.0 F Atmos. Clear. Num. = 1.05 22.49 1.22 1,935 0.132 0.15 20.00 THERMOSTAT SETPOINTS Cooling (Occ) 75.0 F Cooling (Unocc) : 85.0 F Heating 72.0 F FACTORS Coil Bypass 0.050 Safety (Sens) 0 Safety (Latent) : 0 % Heating Safety 0 Is RETURN AIR PLENUM : N • SYSTEM SIZING SUMMARY System Name : OPAS RTU -1 11 -14 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 2 of 2 ****************************************** * * * * * * * * * * * * ** * * * * ** * * * ** * * * * ** TABLE 5. TOP TEN COOLING COIL LOADS Time 1) Sept /1400 2) Sept /1500 3) Oct /1400 4) Sept /1300 5) Oct /1500 TABLE 6. ZONE SIZING DATA Zone Name OPAS RTU -1 Sensible Ton 3.97 3.91 3.93 3.82 3.86 Maximum Cooling Sensible (BTU /hr) 46,436 Total Ton 4.17 4.12 4.04 4.02 3.98 Design Airflow Rate (CFM) Time 6) Oct /1300 7) Sept /1600 8) Aug /1400 9) Aug /1500 10) Mar /1400 Design Time 2,397 @ Oct 1400 Sensible Ton 3.78 3.65 3.60 3.54 3.62 Maximum Heating Load (BTU/hr) 27,829 Total Ton 3.89 3.85 3.85 3.78 3.74 Design Flow Rate (CFM) Selected Zones: ggr4s.trAwuh SIZING SPECIFICATIONS Supply Ventilation Exhaust 145 OPAS RTU -2 HVAC SYSTEM DATA FOR OPAS RTU-2 Table 1. HVAC SYSTEM DESCRIPTION System Type : Clg & Warm Air Htg System Start 700 Duration 10 hrs 57.0 F 635 CFM 0 CFM FAN Configuration : Draw-Thru Static Pressure : 0.00 in.wg. Table 2. SYSTEM ZONING INFORMATION System Arrangement: Each zone Total Zones Selected: 1 Prepared By: STRAIGHTLINE MECHANICAL 11-14-96 Block Load v2.03 Page 1 of 1 ************************************************************************* THERMOSTAT SETPOINTS Cooling (Occ) Cooling (Unocc) : Heating FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety Mq(0- o 'SI RETURN AIR PLENUM : served by separate air handler 76.0 F 85.0 F 72.0 F 0.050 0% 0% 0% N RECEIVED • CITY OF TUKWILA NOV 1 9 1996 PERMIT CENTER GENERAL ZONE DATA Floor Area • 1406.0 sqft Building Weight: M Exposures : N, E, S, W Are Multiple Wall, Roof, or Glass Types Used ? N No. Partitions : 1 LIGHTING W/sqft • 1.20 W /sqft Unocc Diversity: 0 % Wattage Mult. 1.25 Fixture Type : Rec., Not Vented OTHER ELECTRIC W/sqft • 0.00 W /sqft Unocc Diversity: 0 % U -Value (BTU/hr/sqft/F) Weight (lb/sqft) Color EXTERNAL Window Window Reveal PARTITIONS SHADING DATA Height = Width = Depth = Exposure 8.0 ft 4.0 ft 0.0 in ZONE DESCRIPTION FOR OPAS RTU -2 Prepared By : STRAIGHTLINE MECHANICAL 11 -14 -96 Block Load Program v2.03 Page 1 of 1 ***************************** k************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. GENERAL ZONE DATA ZONE NAME = OPAS RTU -2 WALL ROOF 0.050 L L PEOPLE sqft /person Unocc Diversity: Activity Level : Of Sensible Gain . Latent Gain MISCELLANEOUS LOADS Sensible • Latent Unocc Diversity: INFILTRATION Cooling Heating SLAB Area Perimeter Depth ********************************************************** TABLE 2. WALL, ROOF AND GLASS DATA 0.030 L D Overhang Height Overhang Extension Fin Separation Fin Extension Gross Area Glass Area (sqft) (sqft) U -Value Glass Factor Int. Shades ? E Wall 0.0 S Wall 0.0 W Wall 0.0 N Wall 0.0 Roof (Hor) 1,406.0 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 3. PARTITION DATA 0.0 0.0 0.0 0.0 0.0 Partition Partition Type 1 Type 2 130.0 sqft /per 0 % f ice Work 245.0 BTU /hr /per 205.0 BTU /hr /per 0 BTU /hr 0 BTU /hr 0 % 0.05 CFM/sqft 0.10 CFM /sqft 1406 sqft 0 ft 0.50 ft * * * * * * * * * * * * * * ** GLASS 0.650 0.75 N 0.0 in 0.0 in 0.0 in 0.0 in Partition Type 3 Net Area (sqft) 710.0 NA NA U -Value (BTU/hr/sqft/F) 0.050 NA NA Adj. Region Temp (Cooling) 83.0 F NA NA Adj. Region Temp (Heating) 50.0 F NA NA ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** System Name Location Prepared By * * * * * * * * * * ** TABLE 1. SIZING DATA -- COOLING Total coil load = Sensible coil load = Total zone sensible= Supply temperature = Supply air (actual)= Supply air (std) _ Ventilation air = Direct exhaust air = Reheat required = Floor area (sqft) Overall U -value Vent air CFM /sqft Vent air CFM /person TABLE 2. SIZING DATA -- HEATING Heating coil load = Ventilation load = Total zone load = Ventilation airflow= Supply airflow = TABLE 3. INPUT DATA -- WEATHER City State Data Source Latitude Elevation TABLE 4. INPUT DATA -- HVAC SYSTEM System Type System Start Duration SIZING SPECIFICATIONS Supply Ventilation Exhaust FAN Configuration : Draw -Thru Static Pressure : 0.00 in. (_ SYSTEM SIZING SUMMARY : OPAS RTU -2 : TUKWILA, WASHINGTON : STRAIGHTLINE MECHANICAL * * * * * * * * * * * * * * * * * * * * * * * * * * * ** = TUKWILA = WASHINGTON = User Modified 47.5 deg. 97.0 ft Zone Name: OPAS RTU -2 11 -14 -96 Block Load v2.03 Page 1 of 2 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 18,798 BTU /hr Load occurs @ July 1500 17,769 BTU /hr Outdoor Db /Wb = 83.0/ 66.0 F 11,271 BTU /hr Coil Conditions: 59.5 F Entering Db /Wb = 83.0/ 66.0 F 635 CFM . Leaving Db /Wb = 57.0/ 56.2 F 633 CFM Apparatus dewpoint= 55.6 F 635 CFM Bypass factor = 0.050 0 CFM Resulting zone RH = 53.0 % 1,714 BTU /hr = 1,406 Total coil load = 0.030 Sensible coil load = = 0.45 SQFT /Ton = = 58.71 Cooling BTU /hr /sqft = Cooling CFM /sqft 44,137 BTU /hr 33,488 BTU /hr 10,649 BTU /hr 635 CFM 635 CFM : Clg & Warm Air Htg 700 10 hrs 57.0 F 635 CFM 0 CFM Heating BTU /hr /sqft = Heating CFM /sqft = Floor area (sqft) = Overall U -value = Vent air CFM /sqft = Vent air CFM /person = 1.57 Ton 1.48 Ton 897.53 13.37 0.45 Summer dry -bulb = 83.0 F Coincident wet -bulb= 67.0 F Daily Range = 13.0 F Winter dry -bulb = 23.0 F Atmos. Clear. Num. = 1.05 31.39 0.45 1,406 0.030 0.45 58.71 THERMOSTAT SETPOINTS Cooling (Occ) 76.0 F Cooling (Unocc) : 85.0 F Heating 72.0 F FACTORS Coil Bypass 0.050 Safety (Sens) 0 Safety (Latent) : 0 % Heating Safety 0 % RETURN AIR PLENUM : N SYSTEM SIZING SUMMARY System Name : OPAS RTU -2 11 -14 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 2 of 2 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 5. TOP TEN COOLING COIL LOADS Zone Name Time 1) July /1500 2) Aug /1500 3) June /1500 4) July /1400 5) July /1600 TABLE 6. ZONE SIZING DATA OPAS RTU -2 Sensible Ton 1.48 1.48 1.42 1.45 1.45 Maximum Design Cooling Airflow Sensible Rate (BTU /hr) (CFM) 11,271 Total Ton 1.57 1.57 1.56 1.53 1.53 Time 6) Aug /1400 7) Aug /1600 8) June /1400 9) June /1600 10) July /1300 Design Time 635 @July 1500 Sensible Ton 1.45 1.45 1.39 1.39 1.36 Maximum Heating Load (BTU /hr) 10,649 Total Ton 1.53 1.53 1.52 1.52 1.43 Design Flow Rate (CFM) DETAILED SYSTEM LOAD REPORT System Name : OPAS RTU -2 11 -14 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 1 of 1 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. LOAD COMPONENT SUMMARY for July 1500 ( 83.0/ 66.0 F) Load Component Solar Loads Wall Transmission Roof Transmission Glass Transmission Skylight Transmission Partitions Lighting Other Electric People Infiltration Miscellaneous Slab Pulldown /Warm -up Safety Factor Total Zone Loads Ventilation Load Supply Fan Load Plenum Load Thru Wall Plenum Load Thru Roof Plenum Load - Lights Reheat Load Total Coil Loads 17,769 TABLE 2. WALL AND GLASS BREAKDOWN Component Walls : NE E SE S SW W NW N Glass : NE E SE S SW W NW N Details Zone Name: OPAS RTU -2 0 sqft 0 sqft 1,406 sqft 0 sqft 0 sqft 710 sqft 1.20 W /sqft 0.00 w/sqft 11 people 1,406 sqft 0/ 0/ 0 W 635 CFM 635 CFM 0 W 0 W 0 Design Cooling Loads Sensible Latent (BTU /hr) (BTU /hr) 0 0 2,670 - 0 0 248 5,773 - 0 1,999 2,217 530 -118 0 0 52 - 0 0 4,784 0 0 0 0 1,714 ...*. tas....Mf.It•nstd M+fiMogii.Nt.`e rlerot.ttre41M 11,271 2,099 -1, 070 Design Heating (BTU /hr) 0 2,067 0 0 781 7,415 387 0 10, 649 33,488 1,029 44,137 Total Cooling Cooling Heating Net Area Transmission Solar Load Transmission (sqft) (BTU /hr) (BTU /hr) (BTU/hr) 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 - 0 0 0 - 0 0 0 - 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HVAC SYSTEM DATA FOR OPAS RTU -3 Prepared By: STRAIGHTLINE MECHANICAL 11 -15 -96 Block Load v2.03 Page 1 of 1 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Table 1. HVAC SYSTEM DESCRIPTION System Type : Clg & Warm Air Htg System Start 700 Duration 10 hrs SIZING SPECIFICATIONS Supply Ventilation Exhaust Selected Zones: 146 OPAS RTU -3 57.0 F 15.00 CFM /person 0 CFM FAN Configuration : Draw -Thru Static Pressure : 0.00 in.wg. Table 2. SYSTEM ZONING INFORMATION FACTORS Coil Bypass Safety (Sens) Safety (Latent) Heating Safety System Arrangement: Each zone served by separate air handler Total Zones Selected: 1 THERMOSTAT SETPOINTS Cooling (Occ) . Cooling (Unocc) Heating 76.0 F 85.0 F 72.0 F 0.050 0 % 0 % 0 % RETURN AIR PLENUM : N RECEIVED CITY OF TUKWILA NOV 1 9 199 PERMIT CENTER a s.crd wu. q ^. ZONE DESCRIPTION FOR OPAS RTU -3 Prepared By : STRAIGHTLINE MECHANICAL 11 -15 -96 Block Load Program v2.03 Page 1 of 1 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. GENERAL ZONE DATA GENERAL ZONE DATA Floor Area 900.0 sqft Building Weight: M Exposures : N, E, S, W Are Multiple Wall, Roof, or Glass Types Used ? N No. Partitions : 0 LIGHTING W/sqft • 1.20 W /sqft Unocc Diversity: 0 % Wattage Mult. 1.25 Fixture Type : Rec., Not Vented OTHER ELECTRIC W/sqft • 0.00 W/sqft Unocc Diversity: 0 % U -Value (BTU /hr /sqft /F) Weight (lb /sqft) Color .EXTERNAL SHADING DATA Window Height = Window Width = Reveal Depth = Exposure ZONE NAME = OPAS RTU -3 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 2. WALL, ROOF AND GLASS DATA WALL ROOF 0.050 L L 8.0 ft 4.0 ft 0.0 in 0.030 L D PEOPLE Total People 30 People Unocc Diversity: 0 % Activity Level : Office Work Sensible Gain 245.0 BTU /hr /per Latent Gain 205.0 BTU /hr /per MISCELLANEOUS LOADS Sensible 0 BTU /hr Latent • 0 BTU /hr Unocc Diversity: 0 % INFILTRATION Cooling 0.05 CFM/sqft Heating 0.10 CFM /sqft SLAB Area 900 sqft Perimeter 30 ft Depth 0.50 ft Overhang Height Overhang Extension Fin Separation Fin Extension Gross Area Glass Area (sqft) (sqft) GLASS U -Value Glass Factor Int. Shades ? am 0.650 0.75 N 0.0 in 0.0 in 0.0 in 0.0 in E Wall 0.0 0.0 S Wall 300.0 270.0 W Wall 0.0 0.0 N Wall 0.0 0.0 Roof (Hor) 900.0 0.0 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** A.;1 ����. <,.... �e .... , .. 1.; 1Ti!: �n' ri' :�5:'S;e• ° ,:iC>1781`N'F.7 <L�e�. Simnwy'�i.vrm Load Component Solar Loads Wall Transmission Roof Transmission Glass Transmission Skylight Transmission Partitions .Lighting Other Electric People Infiltration Miscellaneous Slab Pulldown /Warm -up Safety Factor Total Zone Loads Ventilation Load Supply Fan Load Plenum Load Thru Wall Plenum Load Thru Roof Plenum Load - Lights Reheat Load Total Coil Loads 34,701 TABLE 2. WALL AND GLASS BREAKDOWN Component Walls : NE E SE S SW W NW N Glass : NE E SE S SW W NW N C Zone Name: OPAS RTU -3 Details 270 sqft 30 sqft 900 sqft 270 sqft 0 sqft 0 sqft 1.20 W /sqft 0.00 W /sqft 30 people 900 sqft 0/ 0/ 0 % 450 CFM 1,593 CFM 0 W 0 W 0 W 2,131 0 0 0 0 0 DETAILED SYSTEM LOAD REPORT System Name : OPAS RTU -3 11 -15 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 1 of 1 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 1. LOAD COMPONENT SUMMARY for Sept 1400 ( 80.4/ 64.8 F) Design Cooling Loads Sensible Latent (BTU /hr) (BTU /hr) 21,856 40 1,152 184 0 0 3,630 0 5,413 6,150 213 -173 0 0 83 0 0 32,570 5,977 -1,733 Design Heating (BTU/hr) 74 1,323 8,600 0 0 4,746 1,185 0 15,927 23,731 4,244 39,658 Total Cooling Cooling Heating Net Area Transmission Solar Load Transmission (sqft) (BTU /hr) (BTU /hr) (BTU /hr ) 0 0 - 0 0 0 0 0 0 - 0 30 40 - 74 0 0 - 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 270 184 21,856 8,600 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M:IM SYSTEM SIZING SUMMARY System Name : OPAS RTU -3 11 -15 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 1 of 2 ** ** *** ** ** ***** * ** **** *** *** ** k** ** * * * **** *** * ** * ** * ** ****** * ***** *kit *** TABLE 1. SIZING DATA -- COOLING Total coil load = Sensible coil load = Total zone sensible= Supply temperature = Supply air (actual)= Supply air (std) = Ventilation air = Direct exhaust air = Reheat required = Floor area (sqft) Overall U -value Vent air CFM /sqft Vent air CFM /person TABLE 2. SIZING DATA -- HEATING Heating coil load = Ventilation load = Total zone load = Ventilation airflow= Supply airflow = TABLE 3. INPUT DATA -- WEATHER City State Data Source Latitude Elevation = TUKWILA = WASHINGTON = User Modified = 47.5 deg. = 97.0 ft SIZING SPECIFICATIONS Supply Ventilation Exhaust ;WeYitIV.V.i.c,f'Y,: *, a ^b+t nv:.S.<ri•7 a Zr �:4:t .�.�::c'.u. u1�.:.C'.Y:e:S.•; ',13•. Zone Name: OPAS RTU -3 38,945 BTU /hr 34,701 BTU /hr 32,570 BTU /hr 57.0 F 1,593 CFM 1,587 CFM 450 CFM 0 CFM 0 BTU /hr 900 0.170 0.50 15.00 39,658 BTU /hr 23,731 BTU /hr 15,927 BTU /hr 450 CFM 1,593 CFM TABLE 4. INPUT DATA -- HVAC SYSTEM System Type : Clg & Warm Air Htg System Start 700 Duration 10 hrs 57.0 F 15.00 CFM /person 0 CFM FAN Configuration : Draw -Thru Static Pressure : 0.00 in. s:.vy+wEy Total coil load = Sensible coil load = SQFT /Ton = Cooling BTU /hr /sqft = Cooling CFM /sqft = Load occurs Q Sept 1400 Outdoor. Db /Wb = 80.4/ 64.8 F Coil Conditions: Entering Db /Wb = 77.2/ 64.6 F Leaving Db /Wb = 57.0/ 56.4 F Apparatus dewpoint= 55.9 F Bypass factor = 0.050 Resulting zone RH = 54.0 qs Heating BTU/hr/sqft = Heating CFM /sqft = Floor area (sqft) = Overall U -value = Vent air CFM /sqft = Vent air CFM /person = 3.25 Ton 2.89 Ton 277.31 43.27 1.77 Summer dry -bulb = 83.0 F Coincident wet -bulb= 67.0 F Daily Range = 13.0 F Winter dry -bulb = 23.0 F Atmos. Clear. Num. = 1.05 44.06 1.77 900 0.170 0.50 15.00 THERMOSTAT SETPOINTS Cooling (Occ) 76.0 F Cooling (Unocc) : 85.0 F Heating 72.0 F FACTORS Coil Bypass 0.050 Safety (Sens) 0 Is Safety (Latent) : 0 % Heating Safety 0 % RETURN AIR PLENUM : N SYSTEM SIZING SUMMARY System Name : OPAS RTU -3 11 -15 -96 Location : TUKWILA, WASHINGTON Block Load v2.03 Prepared By : STRAIGHTLINE MECHANICAL Page 2 of 2 ****************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TABLE 5. TOP TEN COOLING COIL LOADS Time 1) Sept /1400 2) Sept /1500 3) Sept /1300 4) Oct /1400 5) Aug /1400 Zone Name OPAS RTU -3 Sensible Ton 2.89 2.87 2.76 2.82 2.66 TABLE 6. ZONE SIZING DATA Maximum Cooling Sensible (BTU /hr) 33,261 Total Ton 3.25 3 .23 3.10 3.06 3.05 Design Airflow Rate (CFM) Time 6) Oct/1500 7) Sept /1600 8) Aug /1500 9) Aug /1300 10) Oct /1300 Design Time 1,627 @ Oct 1400 Sensible Ton 2.79 2.69 2.64 2.54 2.68 Maximum Heating Load (BTU /hr) 15,927 Total Ton 3.03 3.03 3.02 2.92 2.91 Design Flow Rate (CFM) DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A EQUIPMENT SGHEPULE MARK MAKE MODEL n GEM ESP OSA DRIVE COOLING ``EN /TOT MDH SEER AFUE HEATING N/ OUT MDH WEIGHT MCA VOLTS -PH NOTES RTU -1 CARRIER 48TJD006- -601AA 2000 060 300 BELT 453 / 609 10 80 72 / 592 639 460 V-3 Ph I RTU -2 CARRIER 48TJE004- -601AA 1200 040 635 BELT 260 / 36 10 80 72 i 59 609 460 V-3 Ph 1;2,5E6 RTU -3 CARRIER 48TJD005- -6O,AA 1600 0 40 450 DELT 356 / 505 10 80 72 / 592 619 460 -3 Ph 1,2,5E6 EF -I BROAN 363 PLAN 0325 — DIP — 20 115V -I Ph 4,7f8 DIFFUSER LEGEND MARK DESCRIPTION DE ")GIPTION CD -I -- SUPPLY AIR DIFFUSER FOR T -BAR GD -2 -- SUPPLY AIR DIFFUSER FOR HARD CEILING KRUEGER 1240, 4- WAY THROW, MODULER GORE I BARE SHEETMETAL N RG I -- RETURN AIR GRILLE FOR T -BAR OR FOR HARD CEILING KRUEGER EGG -5, 1 /2'XI /2'X1/2' EGG - CRATE, 12'X24' AIR GRILLE FOR T BAR RG 2 RETURN HARD CEILING OR FOR KRUEGER EGG -5, 1 /2'X1 /2'X1/2' EGG - GRATE, 24'X24' N Dix,-; LEUL ND DE ")GIPTION MARK BARE SHEETMETAL 12'xI2' OR 12' SOUNDLINED SHEETMETAL -- I' SL 12'x12' - I SL OR — 12' - I' 5L — SOUNDLINED SHEETMETAL -- 2' SL 12x12' - 2' SL OR — 12' - 2' Sir DUCT BOARD -- r THICKNESS DD - I' DUCT BOARD -- 2' THICKNESS DB - 7' FLEXIBLE DUCT -- DIAMETER Z\ 12' SHEETMETAL WRAPPED W/ INSULATION -- 11/2' THICKNESS W - 11/2' OR —12'W - I I/2= SHEETMETAL WRAPPED W/ INSULATION -- 2' THICKNESS W - 2' OR —12'W - 2' — "-°-: til• n6aa �' LEF SIDE REAR T _ I . —054.501 Cele 03171555311 MeaE1; 55 FRONT .,ndei Stan d that the PI +n 'Ci pl env does nu; ,. F ri unit 1`ted code of ,.._ tOf SC0r Ot NOTES FROM ABOVE I) COOLING CAPACITY IS AT ARi RATED CONDITIONS, 95F CONDENSING TEMP., 505 DD/67F WO ENTERING AIR TEMP 2) PROVIDE FACTORY METAL GURB 3) PROVIDE FACTORY OUTSIDE AIR EGONOMIZER 4) EXHAUST FAN GEM'S ARE AS INDICATED ON THE DRAWINGS 5) PROVIDE FACTORY OUTSIDE AIR INLET HOOD 6) 7 DAY PROGRAMMABLE THERMOSTAT, HONEYWELL T7200A1006 7) SPEED CONTROLLER PROVIDED AND WIRED BY ELECTRICIAN, 8) INTERLOCK ALL- FANS WITH FAN OPERATION OF RTU -2. Base unit dimensions — 48TJ004-007 .555 170. Tr. Li FRONT KK55 Vus 1 III 6 [15721 aeCIS5 eNIL ETCK512511 10217 tt;Ssa�E� Center ol peony. Gina ion of aimow Fo r tiNria c uNe. M ro M aNCnai snarW De anacriien to ° non- rga nets. vpgiee a tivsarg. .'snit's °��rP�a�.IM��a,onKnan�a Mi tlear ®vn Ibpl m4a or iune0ktion may Pravelll' bas between c Hue ska oral ' ( we c d e nalluees. seqrb) �lga. e A m mnbust�da suMCec mi uvn cu O NE . r vice Bonwn of EARN 140 lag 150 • is 53.5 54.4 660 74.51 100 115 136 CORNEA REARM ae. 522 61.7 Lb 156 162 lfi6 200 ]3.5 ]2.6 sa a ®5,1a = �1 5 r , mma LAMM 0l�OEe MEMO 'Weirs an ter unit only (aluminum plate fins) ana.o not inelude optionS a). COMMOTION AMES v: sNPT Cv4ermse Oran 'h' —]a NPT Gas Cpnnacum ar- I`6 via u � vlEa • -. ° - IatMW At aE. �Iw Horne I rP • RIGHT SIDE — — I I E0 'icfil vlr 7116" suseEs,EO riFCmicu B TM 1 WNW ale SEPARATE PERMIT REQUIRED FOR 0 MECHANICAL ELECTRICAL PLUMBING GAS PIPING CITY OF TUK BUILDING DI's'` =" ' Re 25a 27.2 283 28.0 BQITOM POWER CHART TNESE OlES REQUIRED FOR USE W I ACCE;SORV PACIUGES — CRBTMPWR001A001 v.T CRbTMPWR002A001 „T WIRE 512E CONDUIT .. vlEli 5 -5 REOUWED No�E (RAS) 651a.TpeeS.r[M,R,IGHT SIDE e mea.Em ore plops e Between unie. coned box side. le e. 42 n per r NEC N b01WNn ?Filar unpwlam aunePes. cmua bdwean un F spear mnde wa6z ate m boa m0e, a2 in par NEL. nompnW 'suppry ate reWmeW. 47" 6 Winn 1ne aaupb d the pearario M Db cmaenser ron a�q c°mpus,an swe a9 M1en mNpl�S�.e a� Arar""'77 H aaran<a asepe no ors made ,vn wroPO o� Class A. R w C Accessory dimensions CRRFCUR0001A00 CRRFCUROW2A00 VIEW 'A -A' ROOF CURB — 48T4004.007 ALT DRAIN HOLE NPT tv: NPT NPT 'EMer connector package available for aster rod pule NOTES: 1. Roof Curb acusM]ry is shipped 2. +NNM+tlrndN. De melons n) n numneMN 5. Anon cfw to curb. h noes of duct on p1rb.1 net 6. Service claeranCe • It on each side Orson. of anion SEC - 104 = -C rn q6-b158 Jo PAMPER LEGEND DESCRIPTION VOLUME DAMPER (BALANCING) I HR WALL FIRE DAMPER W/ FUSIBLE LINK SET w 160 F I HE CEILING RADIATION DAMPER W/ FUSIBLE LINK SET W160 F 2 HR WALL FIRE DAMPER W/ FUSIBLE LINK SETA 160 F VERTIGAL FIRE /SMOKE DAMPER W/ FUSIBLE LINK A 160 F AND ACTUATOR MARK E-4 OS- T2 HE SD GENERAL NOTE', I. WORK WILL COMPLY WITH ALL CITY, STATE AND UNIFORM CODES FOR ENERGY, BUILDING AND MECHANICAL- 2. ALL WORK WILL FOLLOW THE STANDARDS SET FORTH BY THE SMACNA RECOMMENDED INSTALLATIONS PRACTICES 3 ALL DUCTWORK WILL BE SEALED IN AN APPROVED MANNER 4 ALL DUCTWORK INSTALLED WILL BE SEISMICALLY RESTRAINED WHERE APPLICABLE 5, ALL GUTTING, PATCHING AND PAINTING WILL BE PERFORMED BY OTHERS 6 ELECTRICAL WIRING AND PISCONNECTS BY OTHERS 7 STRUCTURAL REVIEWS AND MODIFICATIONS ARE BY OTHERS 8 GAS PIPING Ely OTHERS S USE TURNING VANES IN ALL HO DEGREE ELBOWS IN SUPPLY DUET WORK 10 ALL RECTANGULAR DUET WILL BE I' DUCTBOARD AND THE ROUND DUET WILL BE SHEETMETAL WITH I' DUET WRAP VICINITY MAP 0 w a 0 DRAWN CHECKED CMR GUN DATE 11/14/96 SEALS AS NOTED JOB NO 96017 FILE NO 9613MI VGD SHEET / M 1 OF 3 Mato -olsfr GLB I . ROOF DECK MEZZANINE FLOOR SLAB FLOOR o I ELEVATION SCALE: 1/4' - r - EXIST•G SPRINKLER PIPE, TYPICAL m NORTH ECHIXHNA GAUST AP UP, THRU ROOF TO /6'X6' RELIEF LOUVER WITH BDD OUTLINE OF RTU -3 ON THE ROOF ABOVE 450 GEM OSA OUTLINE OF RTU -Z ON THE ROOF ABOVE 635 GEM OSA DRAWN. CM? PATE 11/14/96 `CAI _F AS NOTED J0E3 NO %017 FILE NO 9613M2 VGD SHEET I V CHECKED: GJN 2. Of 3 HVAG ROOF PENETRATION PLAN SCALE I/6' - 1' -0' 12'XI2' INTAKE LOUVER OUTLINE OF RTU -I ON THE ROOF ABOVE 300 GEM OSA 100 GFM EF -I HONEYWELL T67F4002 THERMOSTAT SET AT 40 DEGREES F. IF THE TEMPERATURE FALLS BELOW 40 DEGREES, IT WILL GALL FOR THE FAN TO TURN ON DO NOT INTERLOCK WITH RTU -2 0.10 fv? D r��� t_ S 199 a.l t1LCINC p1VtS�<'' ^� ECEIVE CITY R OF TUKWILA NOV 1 9 1996 PERMIT CENTER V QF ° I Z Dz G Q a al F-~ ceN RE I A AWE M`all I 7.01 ,--" 7 i 8' I /1 / ■ 1 25 GFM 6 • GP-2 6."X6' 175 GFM 25 GFM 1 6'X6' Al 10'X18' 12' 10'X18' 16'X8' UNDER BEAM TYP OF 3 I0• 10' 6' RELOCATED THERMO4 AT ' J NORTH 150 GFM EF -1 135 GFM EF -1 10' 8' 175 GFM EF -I 1150 GFM — RG -2 305 GFM GO-1 10'XIO' HVAG PLAN SCALE: 1/8' - rn qboss 18' 400 GFM GD -I, 10'XI0' TYP OF 4 24'X12' 12'X24' UP TO RTU -3 12' UP THRU ROOF 18 GEM GD -I, 8'X8' P 8'X12' 12'X18' UP TO RTU -2 ' 12'X18' UP TO RTU -2 1030 GFM RG -2 170 GFM RG -I 'WOKE DETECTOR TO BE TIED IN WITH THE BUILDING FIRE ALARM PANEL. BY OTHER', . 18'X18' UP TO RTLJ-I 18 190 GAM GP-I 8'X8' 18'X18' UP TO RTU -I 1260 GFM 18'X18' S RG -2 36'X18 -250 GFM GO -I, 10'X10' TYP. OF 6 12' 200 GFM GP-I, 8'X8' 180 GFM RG -1 -120 GFM RG -1 140 GFM GP-I, 8'X8' 140 GFM RG -I, 8•X8' 160 GAM GO-I, 8'X8' s 0 N' Az N I I N C) — _ j q- Z /}— NC) 0 OQ N H � z < # — _1/4_)_ es H az O —J— ,s, 0 \ S V <W ` H V t10 j � ft JC �p \C RECEIVED SITY OF TUKWILA NOV 1 9 1999 PERMIT CENTER DRAWN GMR CHECKED. GJN DATE 11/14/96 JOB NO 96017 ',GALE A5 NOTED FILE NO 9613M3 MCP SHEET N 3 OF 3