Loading...
HomeMy WebLinkAboutPermit M93-0024 - BOEING #2-63m93-0024 boeing 2.63 7755 east marginal way south hvac `" L1) City o f Mkvt1 L 1 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washingon 98188 Permit No: M93 -0024 Type: B -MECH Category: NRES Address: 7755 EAST MARGINAL WY S Location: Parcel #: 000160 -0020 Contractor License No: BOEINC294ML TENANT BOEING #2 -63 7755 EAST MATGINAL WY SOUTH, TUKWILA, WA 98168 OWNER THE BOEING COMPANY PO BOX 3707 - M /S. 1F-09, SEATTLE WA 98124 CONTACT SID BROWNE Phone: 206 655 -9923 P.O. BOX 39.99MS1935, SEATTLE, WA 989124. CONTRACTOR BOEING INC.. Phone: 206 544 -2975 9725 EAST :MARGINAL :iWY.S,SEATTLE, WA 981242207 Permit Description: INSTALLING A/C UNIT UMC Edition: 1991 * ** x***`**,*********.************** ********* * * * * * * * * * * * * *: * * ** * * * * * * * * * * * ** Permi3 Center Authoriz I hereby 'certify that I have read ',and examined this permit and know the same to be true 'and correct All provisions of law and ordinances governing this work will be complied with, whether specified herein or not The granting of ' this permit does not presume—to give authority to violate or cancelthe %provisions of any other state ,.or :local laws regulating constructi'oh'`.or" the performance of wor I am authorized to sign for and obtain this bui ld,g„ p rmi Print Name: This permit shall becomeul,l and vo.id' t=he work:` i.s:.not commenced within 180 days from the date o .f. <work is suspended or abandoned for a period of 180=da.yom:,- th;e;'last inspection. MECHANICAL PERMIT Status: ISSUED Issued: 02/19/1993 Expires: 08/18/1993 Valuation: 15,000.00 Total Permit Fee: 54.38 ,Date (206) 431 -3670 DEPARTMENT DATE! IN 1 APPROVED PRC�V REQUIREMENTS / COMMENTS BUILDING - initial review a��a' q p 7 CONSULTANT: Date Sent - Date Approved - ) FIRE BY: (init.) FIRE PROTECTION: J Sprinklers Detectors N/A FIRE DEPT. LETTER DATED: INSPECTOR: INIT: BY: PLANNING I ZONING: IBAR/LAND USE CONDITIONS? (j Yes U N SCREENING REQUIRED? Q Yes Q No INIT: REFERENCE FILE NOS.: E OTHER i INIT: X BUILDING - final review (r? ( Z. UMC EDITION (year): l ci INIT: ',.,0 ■ BUILDING OFFICIAL /V l NIT: ' "-eA'; AMOUNT OWING: CONTACTED i /) l {X_ l ) DATE NOTIFIED <-9' 11 —15 BY (init.) ) 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: PLAN CHECK NUMBER CITY OF TUKWr 1 ( __ Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking REVIEW COMPLETED PROJECT NAME ZnE I Is # a —(03 SITE ADD SS - •� 1 - 755 A-S1 MAR5i0A -L LOV S INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. +t;Y Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. SUITE NO. 01/07/93 SITE ADDRESS SUITE # 77.E ec . /L /4- =7N// -L ,) I y S� VALUE OF CONSTRUCTION - $ /5, 0490 ADDRESS '773:3 Z• /t; 5 /ti/9z. €__)y L,. PROJECT NAME/TENAN ;7" 1 /A/Z- /Z71227, ,,2. C .,CC' /}lGks 73 --G/ CONTRACTOR 70// c - TYPE OF WORK: ❑ New /Addition ❑ Modifications ❑ Repair (Other: / ,,,q,U, T,ivno ADDRESS DESCRIBE WORK TO BE DONE: /- / / ) ef7 /.L —0 s y ail: )._.5;�// ./ 4 G /,u2 . WA. ST. CONTRACTOR'S LICENSE # >;: ::,:: >; >�: »:<:;:::::<�:. :s:: >: »::::::.::;: <:::: »::.: . <:::;; >;�<::. T C/51Z :::: ><::«:.: °;::`��;.:<�:: ::. >: >: >NtlfViBER tJF;iINTTS ... TYPE.... ...... .. RA .IN E ...., ,.:: PLAN CHECK FEE OTHER :TOTAL. BUILDING USE (office, warehou e, etc.) O X /e /. 4 NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? [ 'No ❑ Yes IF YES, EXPLAIN: WILL THERE B,�E,y$- TORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? t_7 No ❑ Yes IF YES, EXPLAIN: PROPERTY OWNER ,3D „r/d- n /1./r%`JA.-'y PHONE ADDRESS '773:3 Z• /t; 5 /ti/9z. €__)y L,. ZIP CONTRACTOR 70// c - PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ::DESCRIPTION ' : AMOUNT : <RCPT:#:: :.DATE ': BASIC: PERMIT: FEE :$15.00 UNIT(S) . FEE ': : . :. . PLAN CHECK FEE OTHER :TOTAL. ITf1 RR BUILDING OWNER OR AUTHORIZED AGENT ADDRESS CONTACT PERSON CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK 1 p J °Da/4- NUMBER JU �� APPLICATION MUST BE FILLED OUT COMPLETELY MECHAILCAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) XAM IN. PHONE CITY /ZIP Ey7 - 7--2 PHONE 77".5 e //% /4 / /fL Jy 6 ,2f) - aC 3 99y / / 35 �.cliGtJrt/ / %l42.41 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. A completed "Mechanical Permit Fee Worksheet" must accompany this permit application. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for titan review. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No appk§tigp, hall be extended more than once. If you have any questioiiiraliiiitibinitocess or plan submittal requirements, please contact the D artment of Community Development at 431 -3670. • DATE APPLICATION ACCEPTED 4' ERM1T CENTF ATE APPLICATION EXPIRES I 06/1 8/D0 SUASMITTAL CHECKLSST MECHANICAL n Completed mechanical permit application (one forr each structure or tenant) El Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. 1 Address: 7755 EAST MARGINAL WY S Tenant:. BOEING #2 -63 Status: ISSUED Type: B -MECH Applied: 02/12/1993 'Parcel #: 000160 -0020 Issued:. 02/19/1993 ************* * * * * * ** * * ** ** * *** ** ** **** * *** * * * *** * ** h *** *k** * *'k * **k * * * * ** Permit Conditions:. t Energy' CO de x;(1991 Secohd Ed.i . ...::.' _'' 4 ' �. fi r. �.. t i � . . �, � � 5 Readi?1y aocessAble S ao 'Ss, raaf ma'urit'ed- ;e.quipment is oh? required. / h. tz . 6. Va14'0 ty ofei P d er rpi The i 3 pf a �'permi't or approval pl eas, specifications . +`a.iid • co yputatAonsl shall not be opt,- stru `y�� ,d to, =be a permit. ar, y or,. ti a n ap . any vio�lat�ion, of I et.4.e . h provi;s'i ons� 'f . th'`i's, co 0-or o•f` any other' ordOnce of the jt i' dicF on " --,,N. f)er1m pr i;o rivek U,. aut i ty oa' r~ violate o cancel t e'9 a`�iavi an of this c Chi I t.L',sV (i.. a. 1 t , CITY OF TUKWILA \ 1 v »..d Permit No: M93 -0024 ,.a f • ***,*********It*************************************ir************ . ., . . • • . - '‘'. ' , :...' , . . . . . ... . . . , ,. ..- . .. . . .. . . . . • .. . . :: ... .. . , . . , . . . . . - . TRANSMIT .-.54.38 02/19/ 1 .. 4:46 ' B-MECH MEPIYINIC AL! 13,B11.A ‘' • Total Fees: 54.38 Total GENERA 10.88 O,/rfY" OF .TUKN, NA • l'ss4i;c'c 41*** it*ic * 144! * *** ir * * *It TR Number , 93000240' Amount: No::-)i93.-6024 Type:, • Parcel No: 000.160-0020 Site Adtiress: 7755 ;EAST' MARGINAL NY S Payment Method. CHECK --Notation: BOEING COMPANY .Irtit: SAO. ****•**** Account Code : ..'DesOription , Raid 009/345".830 PLAN CHECK - NONRES 10.58: GENERA TOTAL CHECK 43.50 • 54.38 8 000/32:4.100 MECHANICAL - NONRES 43;59, Total (This Paynient): 54,.38 Address: 7755 EAST MARGINAL WY S Tenant: BOEING #2 -63 .Status: ISSUED ,Type: B -MECH, Applied: 02/1:2/1993 Parcel #: 000160 -0020 Issued: 02/19/1993 *• k*********.***********************.**• k********* * * * * * * * * **•k * * * * * * * * * * * * * * *•k ** Permit Conditions: 1. No changes will be made ,.fi t e s nJ ss approved by the Architect and the •T 1aii,1 i` -Bui"Td niv'iV1:o;h..t, 2. Electrical permit.��•�il�`i��i be bta��ined�''�0 4rthrough •"th ._ �' a'" + �: w k win; -� State Division; .L�` bor and thdust ies andya 1 electrical • ed .work will bepect t hat ,gency x ,(248 - ..66 57) .' ��.,,..‘t. 3. All permits p , c ,f-n.r� A r�ecor ds, and apprdve;d, plans shall be � > " �;r a \.. s maintaine / vai,l,ab'1ce 5 at the.�:•j'db � si t prior to ;tj �e' star sOf a ny cons r ct on � ii These docu�n e , t are to be ma iln n,ed ; avai lab" e /unt 1, f i al , t nspect1Ydn ,; ppr oval is gran \'it, 4. All co truction to 5be done 'i conformance with.. app ; owed '{� plans,,, f e u irements o f ,':t h , Uniform Building (.ode (1j<9911 Edit o $, a's am e n d t ed by'.ehe Washington Stat Building i'Co }, Unif �r M�.e.c dni l Code (1991 Edlti.on and Washing +tori` State • Ene g - C • de x(19.1 Second -E.di� l SIT' ' . Rea "1� y 'c <ce'ss i'b l e a.ccbss to i^ of m - �, u i pment 4 s or approval :.of i'd''`*.cb `putet shat 1 not be con ` °r ' `� st lead to be. a` pe'niit or a n a�pp o "of „ , any violat: n 'Of g,, �. i .. or y . i. .. . ...... the afo s �, s ., .. Nf an oirher r ord nce oo"f the JUr�,i 4 c� r . ton. 'No ,} e, y m,iit pr suming ' g ive aut i ts, tort v1,o l ate or cancel t prov s 1.ons � f this c' .de shat' a v'1id .� . � N�... , , v 0 it d ../ ti 0 CITY OF TUKWILA Permit No: M93 -0024 Project: A pr All NO' . ypeo ns. i .n: pp. • • nstructlons; — Date Wanted: /a c5 am. p.m. Requester: Phone No.: moor ❑ $30.00 REINSPECTIO EE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION. RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. . ❑ Corrections required prior to approval. .:b ro ec : ! ^, ype o nspec an: (-01— 4-- /ii Address: 7 7 �/( ,/ 7 LGe�� Date Called: V Special Instructions: — Date Wanted: 71 a m. Requester: - /Il Phone No.: 61.5:5 f G Q. COMMENTS: INSPECTION RECORD Retain a copy with permit' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 MP3 c192/ PERM' (206) 431 Approved per applicable codes. O Corrections required prior to approval. I Inspector: ) 1 A . / ` tile: i �± O $30.00 FEE REQUIRED. ,prior to reinspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call•to chedule reinspection. x• Jul 08, 1993 SID BROWNE P.O. BOX 3999 MS 1935 SEATTLE, WA 989124 Dear Permit Holder: Sincerely, City of Tukwila Denise Millard Permit Coordinator Department of Community Development John W. Rants, Mayor Department of Community Development Rick Beeler, Director Our records indicate that on Aug 18, 1993 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechnical Permit Number M93-0024. Unless you call for an inspection, or obtain a` written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Aug 18, 1993. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. 6300 Southcenter Boulevard, Suite. #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 APPROVED DATE REVISION ad TH5 INCH OY APPkOVEa � L II : I : IIII I 0 £ 6Z 8c: LZ 9Z SZ tZ 1 ! t �Illll,i {{ ( t i I ill,i�ltll,llilil II{II I nll�nnl iIIIII11r DATE CONSTRUCTION OCCUPANCY SEISMIC ZONE 3 ENTIRE BUILDING IS SPRINKLERED FACILITIES DEPARTMENT D AUBURN, WA. 98002 EVERETT, WA. 98201 L7 KENT, WA. 98031 CI PORTLAND, OR. 97220 D RENTON, WA. 98055 SEATTLE, WA. 98124 5 6 / x; t,.::,Y'�"..:t seb ,.,^a: `- �Csz*..ar'iba:yte8:vbe'.0 `s- •rA,e;'}t's C °rcY _" Y NOZE s '`ff are �u d cumeni is' less c) ear than this ' � not1 e, it is due to the quality of the prigtna1 documeDt. ee tZ Qe 64 8t _ at 94 5t bt et El tt 0I, 6 8` 6 li �111JU1 lih {11 !lI!I tiiiillli�llii!HII i1llllll'il'' •1 + I I i I .II,I II I(l,illlil {1r CI1111( I�lill� l�Illlllllll.i�lllllllillt Jiilif ! II •... � .'^ ,, tirrS.''.:� "t'� :.i'� ` .+'44 - :E :'' ! - -,t >u `"-.:.1f - ;[ ti ��'nt.,y , ^ty^'�'�✓.:.s`r�:s x ,,';, �'S,�,,�, }� ..� ,s r� � , -fi, �,.yy> : � 1114* 12 S I1 . .1. r I Ii1.Illii�l It, IIIIl IIIIIIiI {1 {il!,iIIIIIIII�I�.IIIiIIII� ACCEPTABILITY 1'Is DESIGN AND/OR SPECIFICATU N IS APPROVED DEPT. IATE APPROVED BY APPROVED APN: 000160 A TRACT OF LAND BETWEEN THE DUWAMISH WATERWAY AS ESTABLISHED BY COMMERCIAL WATERWAY DISTRICT # 1 OF KING COUNTY, WASHINGTON & E. MARGINAL WAY, IN SECTIONS 28, 29, 32 & 33, TOWNSHIP 24'N, RANGE 4 EAST, W.M., DESCRIBED IN KROLL BOOK PAGE 79. TRACT CONTAINS AN AREA OF APPROX 2,897,955 SQ FEET. DRAWN BY DATE SUBTITLE J.GRAY ' 2/3/93 CHECKED ENGINEERED BY DUCTWORK PLAN MEZZANINE K ati -� v {Zt' :� th .,t the p{t► . 3 ►� ►i.:a+ t . andQ►fiiSy ) , y ;poi r ors .t } not authorize ►.►i . P � ce t r • ,, �k - ' o� ofd — �. E• eip { t ' foorewarro.a.o.0 1 t. geCi. `code {a1�s � t SEPARATE PEMATT IRE QUI ED FOR 0 ELECTRICAL 0 PLUMS** 0 GAS PIPMG amt OF 10 o BUILDING 2.83 LA T RE I ION SH ET DWG. NO. t:. RECEIVED CITY OF TUKW 1A FEB121993 erNTER • T DATE SPECIFICATION IS plumbing APPROVEd LAST REVISION 3 / 4 " CONDENSATE DRAIN ONTO ROOF. SLOPE REVI 2 1/2" CAS (UNDER) 2 '1 /2" CTWR oc 6 se Y P,PRRovE0 SCALE: SENJEAMIEMfal I AUBURN , WA 98002 EQU I PVENT LIST DESCRIPTION SEE DWG. 2.63 —RFM12 [12....›- ADAPT 3/4" COPPER TUBE TO CONDENSATE DRAIN F I T T I N G . ELBOW DOWN APPROXIMATELY 6" . 8 TEMPERATURE ACCEPTABI LITY TFt.I S DESIGN AND/OR SPECIFICATION IS APPROVED CFM DRAWN B�Y SHEARN R.GLADNEY. ENGINES' �~ W. BOLLIG CHECKED __ (Pl' p GE IR i NG 1 49- APPROVED TITLE EQUIPV E \T LIST DESCRIPTION ROOF EXHAUSTER, PENN MODEL LB24 5325 CFM „ 0.125" SP , 660 RPM, /4" . : V /60 HZ/ /BD DAMP A I R -COND I T l ONER,' CARR�I ER MOD 500005 -5 NOMINAL 4 -TON CAPACITY, R-22 FAN: 1750 CFM ® 1:8" S.P. i382 RPM, 1.80, HP, OPTIONAL BELT DRIVE OPTIONAL 2.0 HP MOTOR HEATING COIL: ELECTRIC RESI STANCE, 13 KW ELECTRICAL 23.4A WIRE SIZING 30.`OA OVERCURRENT PROTECTION CONTROLS: CARRIER MERCURY BULB THERMOSTAT IN ROOM ROOF EXHAUST FAN- UNKNOWN MFG. ASSUME SIMILAR TO GREENHEK MOD. SPF 30 FAN : 9300 CFM @ 0.25" S.P. 800 RPM MOTOR: 1 H P, 800 RPM 115 V/60 'HZ /1 16A CONTROLS: THERMOSTAT MOUNTED 12' ABOVE 17 FLOOR, SET TO 85 F. ON /OFF SWITCH ON ROOF IN FAN CAB I NET . CO \STRUCT O\ \SOT ES INSTALL 1.0 HP MOTOR. ADJUST FAN SPEED TO 800 RPM. INSTALL ROOF CURB "ON PLATFORM. CUT. HOLES IN ROOF. COORDINATE ALL CRAFTS. INSTALL SUPPLY AND'RETURN DUCT. SEAL ROOF. SEE SKETCH NO. 35G 2/3/93. • I "NSTALL CARRIER PACKAGE w* A I COND I T i ON I NG UNIT. ADJUST FAN PER EQUIPMENT LIST. KEY PLAN SCALE: NONE BUILDING 2.s3 MECNAN1 CAL. 'MASTER Cbl. 14-20fA -K PLT 2 'FEB , `2 199 EQU 1P\ENT LIST NO. DESCRIPT1ON. EF SEE DWG, 2.63—RFM 12 fieN WI§ ROOM AC 01111. CARRIER MODEL HKA 3333 32,000 BTUH, 555 CFM, 208 V, 1 PH, 60HZ,: 4265 WATTS R°QM AC UNIT. CARRIER MODEL HKA 3333 32,000 BTUH, 555 CFM 208 V, 1 PH, '60HZ, 4265 WATTS AIM Al4 AIR HANDLING UNIT—AMERICAN BLOWER MODEL 486-38 ,, FAN: 26,800 CFM @ 2 S.P. MOTOR: 15 HP, 1460 RPM, 19A 440V/60' HZ/30 FRAME 326 AII L. EF .." ,,, EXHAUST FAN—ALADDIN MODEL B165C , ,, FAN: 1520 CFM @ 960 RPM, 0.74 S.P. WOTOR:? H.P. RPM 115V/60 HZ/10 5.4A EXHAUST FAN—BUFFALO 3-3/4 INSTALLED 10/48 Fm:, 5260 CFM @ 0.815 S.P. MOTOR: 1 HP,1,6A 440V/60 1Z/30 AS I LT R.A. UP 16Xt6 5000 CFM APPROVED DATE 13X7 20X7 Aid,04.44,01-.>,ir*yeeAsktio . 12X18 S.A FROM REVI8ION T 1-.1y4 555 CFM'Il 11X26 P.A. UP to 26X40- 18X25 -SEE-1Mi2 DATE document' is less clear than this notice, it is due to the quality of the original docusent, 17z ( te oz et et ! Lt 91. 91. hl et Zt CA 8. 9 • - • c] AubblN, 980o2 ID EVERETT, WA. 98201 Cl KENT, WA. 98031 PORTLAND, OR. 97220 1.,3 RENTON, WA. 980 124 55 VA SEATTLE, WA. '9'8 66■144giiifil 4FONSR SPECIFICATIvN APPROVED BY 'riff. ATE E :: 1 4511AY 1 • 1 c )RAWN 8Y. R:GLAONEY 2 4/93 DATE. J . QRAY 2 4 93 CHECKED W158 Airlirobvitb 2/4/93 SUBTITLE T ITLE 'MECHANICAL MASTER_ 1100.-. PENETRATE ROOF WITH 24 GAGE 18"X12 DUCT. SPLIT DUCT. TURN EAST AND WEST WITH '26 GAGE 9"X 12" DUCT. or- ELBOW OVER AND TRANSITION TO 11"X 5" EXISTING DUCT. [›. RUN 26 GAGE 9"X 12" DUCT. TAP OFF WITH 26 PAGE 9"X 6" DUCT DOWN TO FLOOR. TRANSITION TO 8"X 4". „„. 4 RUN 26 GAGE 9"X 6" DUCT FROM TRANSITION AND DOWN TO FLOOR. TRANSITION TO EXISTING 8"X 4" DUCT AT FLOOR. [T>. RUN 22 GAGE, 16"X 16" DUCT UP. ELBOW OVER . DUCTWORK BUILDING 63 - INSTALL 16"X 16" BETWEEN EXISTING DUCT, UTILITIES AND EQUIPMENT. • ELBOW UP WITH 22 GAGE, 16"X 16. FABRICATE AN CONNECT 20 GAGE TRANSITION TO 20 GAGE 11"X 2 'ROOF PENETRATION. INSULATE ALL EXPOSED SUPPLY AIR DUCT WITH 1-1/2" THICK, 0.6#/SQF DENSITY FOIL —BACKED FIBERGLASS DUCT INSULATION. WRAP ALL SEAMS WITH FOIL TAPE. SCALE: NONE LAST PTV I SION SHEET ,votom064110401101WOOMMIUM APPROVED FACILITtES : DEPARTMENT II SPECIFICATION 'APPROVED BY DUCT HEATER DRAWN R.GLADNEY PETRAM 10-20-86 300CFM TITLE SEE DETAIL M12IM500 EQUIPMENT L_ I s TREF DESCRIPTION NO. „ 2.5KW ELECTRIC REHEAT cOtL u) IN DUCT WITH TIME PROPORTIONING SWITCH 25KW ELECTRIC REHEAT COIL .0 IN DUCT WITH TIME PROPORTIONING SWITCH /T\ SEE DWG. 2: 3-RFM12 Ai gi..9 fa . . • ., llik SEE DUCTWORK BUILDING 2.63 MECHANICAL MASTER COL. 14-20/A -K MAiSVAida LEGEND g SUPPLY AIR FLOW TURNING UP SUPPLY MR FLOW TURNING DOWN El RETURN AIR FLOW TURNING UP E] SUPPLY AIR FLOW TURNI46 DOWN HUMIDIFIER t ENLARGE WALL OPENING TO 16"X16". INSTALL 22 GAGE, 16"X16" DUCT. ROUTE THROUGH WALL, THEN ELBOW UP TO MEZZANINE. ADJUST AIRFLOW TO 440 CFM AT EACH D FFUSER ( TYP I CAL 4) . INSTALL THERMOSTAT ON COLUMN I NCLUDE NOTE "CALL MAINTENANCE IF RED LIGHT 1 S ON " . Fl et F00000 LAST REVTSION ISYM DATE JOB NO. 163180 DWG. • NO. PLT 2 2.63 -1m12 WAS 102-063:4001 2/3/93 REF NO. DESCRIPTION 2.5KW ELECTRIC REHEAT COIL N DUCT W T I ME PROPORT ION I NG SWITCH 2 KW ELECTRIC REHEAT coiL DEPT • SEE DWG. 2 63—RFM12 411 Y, SEE DWG. 2.63 RFM12 cuj kli 17 Ali ,ACCEPTAB , THIS DESIGN SPECIFICATION IS I L I TY AND/OR APPROVED DRAWN BY OLBY DATE 1O/18/8 1 Y 1 0-18-86 , ()-20-86 10-21-36 [SUBTITLE DUCTWORK dIF - ENCINAR CHEC a. D ,..., 'TRAM WR:O APPROVED B APPROVED Y- DEPT • )ATE TITLE BUILDING 2.93. IvIECHAN I CAL MASTER COL . .::::Dir BY SHOCK J11163'180 BC RFC RENUMBER DWG TO NEW STANDARD WLS HISTORI SERVICES J 7" D REPLACE DUCT/AIR CURIA IN J#700021-00 WLS , E Abb AC-1 J# JO 0, TH S DRAWING HAS BEEN RELEVELED TO THE 1968 LEVEL LIST (A)(M) gial$041 &NW 1 2 .. k 8 R " " 4 • V" • - ",".- 1750 CFIv1 . 5000 CFM DATE 10-21-8 2 DEC86 WDB WR 9 DEC86' RDS 4 / 9 /q 0 2/18/ 0 7 Rrvisiori BY 6APERATURE IN MCHIVES 4720203 —01,02-----hs jcG A DATE FEIREMsgs 0 AUBURN, WA. 9800 C_I EVERETT , WA. 98201 I 0 KENT, WA. 98031 D PORTLAND, OR . 97220 0 RENTON , WA. 98055 SEATTLE, WA. 98124 wift: If the microfilmed document is less clear than this ■ . f ' notice, it is due to the quellity of the Original document. z za ta 0 8 e.t a hl 91 GI 4 7L et et It 01, , _ . . 411111411 uilju 11Jihnhillonhothinlmilml x-ezeRAI - "-;.' -;-- ' ' - - — - - - - .:iYA 4 9 S 4 7 k: 2 1 7 SEE DETAIL M12 M500 R AOVA L. aN NOTES REMOVG C= 'DUCT l'KEMOV K)61 FAN, - FA3R( MerAL_ COVEF WrceiZ.* LEGEND 1M SUPPLY AIR FLOW TURNING UP Ei SUPPLY AIR FLOW TURNING DOWN zi RETURN AIR FLOW TURNING UP SUPPLY AIR FLOW TURN I NG DOWN EP HUMIDIFIER ,<EY PLAN JOB NO. 163180 REc.,,' OF iU , FEt3 j 2 PERMIT CENTER DWG. NO 0/A-K PLT 2; rvAs'' ___----- 5000 CFM APPROVED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED 8Y DEPT. PAIE APPROVED MCCILIANICAL-MASTER COL.. 14H20/AK DRAWN BY DATE, GRAY 2. • R . GLADNEY 1 - 09 - 87 N IN 1-09-87 CHECKE1 SUBTITLE TITLE BUILDING 2.63.M1 SUPPLY AIR FLOW TURNING UP DD SUPPLY AIR FLOW TURNING DOWN Ll RETURN AIR FLOW TURNING UP z SUPPLY AIR FLOW TUNING DOWN 41kiagNadaliA NOTES 8" )‹ -" D PERMIT C6i•TER LAST REVISI UN - I DA SHEET JOB O. -- M1M12 720203 i 4U4/ PLT 2 2,63 —M1M12. D". NO. EQUIPVE\T LIST REF . DESCRIPTION SEE DWG. 2.63 RFM 12 Lek I' 19 ROOM AC UNIT. CARRIER MODEL HKA 3333 32,000 BTUH, 555 CFM 208 V, 1 PH, 60HZ, 4265 WATTS 4113 7 A , 1 " 1 %—J ROOM AC UNIT. CARRIER MODEL HKA 3333 32,000 BTUH, 555 CFM 208 V 1 PH 60HZ 4265 WATTS AiliN Q.:: AIR HANDLING UNIT AMERICAN BLOWER MODEL 486-38 FAN: 26,800 CFM @ 2" SP. MOTOR: 15 HP, 1460 RPM, 19A 440V/60C/30 FRAME 326 EE 7 - 7 'VT EXHAUST FAN—ALADDIN MODEL 6165C . FAN: 1520 CFM @ 960 RPM, 0.74 S.P., MOTOR: HP.,1725 RPM 115V/60C/10 5.4A ___ Am EXHAUST FAN—BUFFALO 3-3/4 INSTALLED 10/48 FAN: 5260 CFM @ 0.815 S.P. MOTOR: 1 HP.,16A 440V/6'0C/30 ; SEE-11 g48.- 61.S 5000 CFM APPROVED DATE kiT 555 CFM Ift Ts INCH 7 I g • i notice, it is due to theA Laity the C 6Z LZ 9Z sz ez • tZ 6t . LA 91 GI. tt et ..81. ri Iffl irihnu ffiiinI4Hilinihniiniihni,iitttlimiliOhnilinhiwin4191111111140 C3 AUBURN, WA. 98002 0 EVERETT, WA. 98201 0 KENT, WA. 98031 E3 PORTLAND, OR. 97220 0 RENTON, WA. 98065 PI SEATTLE, WA. 98124 4 , NOM If the .microfilmed document. 1.8 less .clear than thin i notice, it is due theA ality'T:nf the Oiginal: docunent . 4 6 8 4 , I 1 1 I 61011 1111 nil 111J I 1111 alr'vg"Teifizzatimm ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED 8Y DEPT. PAIE APPROVED 7i 140.'871. ' . MCCILIANICAL-MASTER COL.. 14H20/AK DRAWN BY DATE, GRAY 2. • R . GLADNEY 1 - 09 - 87 N IN 1-09-87 CHECKE1 SUBTITLE TITLE BUILDING 2.63.M1 SUPPLY AIR FLOW TURNING UP DD SUPPLY AIR FLOW TURNING DOWN Ll RETURN AIR FLOW TURNING UP z SUPPLY AIR FLOW TUNING DOWN 41kiagNadaliA NOTES 8" )‹ -" D PERMIT C6i•TER LAST REVISI UN - I DA SHEET JOB O. -- M1M12 720203 i 4U4/ PLT 2 2,63 —M1M12. D". NO. SD *ASPHALTIC PAPER MOPPED ON EXIST Rte, DECK AN D ' ROOFING .6" MIN. 2z6 CURB ASPHALTIC EMULSION PLASTIC FLASHING EXIST. ROOF DECK AND ROOFING---- TEMPET.A r UR ASPHALTIC SATURATED PACKING %° FLAT BAR RIN CLAP M16�1. z A. GALL! FLASHING ZE A. SHT. METAL' C CLLA ASPHALTIC . CM MS ION 484 PAPER MOPPED ON