Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M93-0161 - STAR HEATING
144 4 , ;‘, 5TM ATUJ r Ci o 7ttkwili Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: M93 -0161 Type: B -MECH Category: NRES Address: 12600 INTERURBAN AV S Location: Parcel #: 000480 -0003 Contractor License No: STARHC*072M9 TENANT STAR HEATING 12620B INTERURBAN AV S, TUKWILA, WA 98168 OWNER THE SAMMIS COMPANY 6755 S 216TH, KENT. .WA' 9,8032:. CONTRACTOR STAR HEATING 12620B INTERURBAN "AV S,, TUKWILA, WA 981.68`; CONTACT RANDY JENSEN " 126208 INTERURBAN AV S, TUKWILA, WA Permit Descri- tjon: INSTALL; NEW HVAC ROOF TOP `,UNIT e2 1/2 TON) . UMC Editions 1.991 Signature:_ Print Name:_ MECHANICAL PERMIT ********* * * * * *, **k * * * * *•k. * *•k * *,* * ** ** *A * *. *•k * * * * *•k * * * * *k * *****•k *k i * * **k* _1 t5-- ci "3 Permit Center ..Authorized-,"Signat,ur'e ,.Date I herebyAcert"ify that `I. have read;, -and examined this permit and kno0he same to"° true an"d correct. ,'Al'l 'p'ro,vision 's of law and ordinances governing th work will 'be'' complied ".wi..th ;";.whet "her:,specif.ied herein,. ; :or not .. r The grant of�this"" permit does not presume;'t.o give authority:to';v.iolate or cancel`6the !pro,,visions of any other s or ":Local laws regulating constructisbn or'' th- performance of work. " I: sm authori`zed to sign;: for and obtain this buil permit. . n /\ t Valuation: ,Total Permit Fee :. ✓' Date,: 1D Title: „C[x Phone: Phone: Phone: (206) 431 -3670 Status: ISSUED Issued: 10/15/1993 Expires: 04/13/1994 206 241 -8454 206 872 -9600 206 241 -8454 206 241 -8454 ,000.00 '• >' 3 0. 0 0 This permit shall becomey".;null and vo if`;ahe wor...k: not commenced within 180 days from the date of su.anc,e., or if ,irhe work .is suspended or abandoned for a period of 1'80 days from ;the 1ast` "inspection. AMOUNT OWING: '0 CONTACTED DATE NOTIFIED BY: ,�p� (init.) �--�i J 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER 1 0'1 6 13 - lo O FIRE PARTME BUILDING - initial review O PLANNING O OTHER X BUILDING - final review BUILDING OFFICIAL CITY OF May" 4 Department of ommunity Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED PROJECT NAME 5 4)4 SITE ADDRESS I a (QD_T) 3 Snt-eY u r kr 11i3 ( l ,JROUTED INIT: INIT: INIT: "OPROV.E REFERENCE FILE NOS.: UMC EDITION (year): REQUIREMEN1 CONSULTANT: Date Sent - SCREENING REQUIRED? Q Yes 0 No SUITE NO. i Date Approved - FIRE PROTECTION: O Sprinklers Q Detectors DN/A FIRE DEPT. LETTER DATED: INSPECTOR: ZONING: IBAR/LAND USE CONDITIONS? L) Yes U 01/07/93 SITE ADDRESS SUITE # / 2 G 2© ) j kery r 64t) IF S o VALUE OF CONSTRUCTION - $ SOOO' PROJECT NAME/ NANT 5 - r J- �t�f Se/ rr iS arc, P ASSESSOR ACCOUNT # 0 00 Da 0 Other: C TYPE OF WORK: Q New / \ ddition Modifications 0 Repair DESCRIBE WORK TO BE DONE: :::::::::: > °• .:•TYPE <. .; :> •..:RATfNC�ISIZE. .,..:.:• : ::.::.,.:...;::.:.<.::•...::... :.:. :::.::. :.NWMBERa�UNR'5���< >;:::;: ><:;: I.ur:Ti�l. s. I Z. "_ AN v+ O P1-1 1 sk V t .-t- EXP. DATE BUILDING USE (office, warehouse, etc.) O 'T t cSZ NATURE OF BUSINESS: 7q WILL THERE BEA CHANGE IN USE? gl"No Q Yes IF YES, EXPLAIN: WILL THERE B ORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? IF YES, EXPLAIR o 0 Yes PROPERTY OWNER ....5"-e7 rY 1 CQ p PHONE ADDRESS l it, p 0 ( i -pp e V ( PlZ>G-r S 0 ZIP / C CONTRACTOR 5m 4 2,1 4 / 7 14.1 PHONE 2 � / ?x/ ADDRESS 5� KQ ZIP / --7 / /519# WA. ST. CONTRACTOR'S LICENSE # s-T-gz H C _ g EXP. DATE CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK ( l 5 0 � l-V NUMBER APPLICATION MUST BE FILLED OUT COMPLETELY BUILDING OWNER OR AUTHORIZED AGENT HER >CERTIFY:THAT.I;HAV.E.READ AND :EXAMINED.THISAPPLIGATION AND KN. D : CORRECT AND I AM AUTHORIZED: TO APPLYF.OR.THIS PE IT ...:... ...... :' CONTACT PERSON ADDRESS J APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER/AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensee by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED MECHAN' IAL PERMIT APPLICATION Mechanical Fee Worksheet must also be filled out and attached to this application. FEES (for staff use only) :DESCRIPTION BASIC PERM ITFEE UNIT(S) FEE PLAN CHECK FEE ' OTHER: AMOUNT' % RCPT::# 4I DATE APPLICATION EXPIRES CITY/ZIP .9f/6 7 - PHONE 2_ y/ — t/ `HQ- I -1 0(H07N. • SUBMITTAL CHECKLIST •••■■•• MECHANICAL Completed mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. 7 Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. E. O -. . 0. F- • w E I - w • _ __..._:' .- .- •_.__1�'-R�_ _ _ rear j... - DEPARTMENT OF LABOR AND INDUSTRIES TFNS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A rS fjiC K- ATT Na :4 GAOLI hG - 121608 .'INIE•IWRBAN. A;YE` S E: SEATTL "- WA 9 . 8 i 6 . 6 . - 'STATE OF WASHINGTON r ; ypeo ns• : - .n: f _.„ Av :00 .,,-Aikial ' A 14 Ai J .Date Called: /0. —are.7 Special Instruction s:,� G -,(4.0 ,24.,42. ic /O; Ai/ 5 -- 4L vbillo Date Wanted:. �� `t-�� v g.3 ' fp.m. Requestey nw, 1?/c...- Phone No. : ?. // , Y� 5- Y .., -�� : �.. . • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. nspector: Reoept No.: INSPECTION RECORD 0 ' Retain a copy with permit ❑ Corrections required prior to approval. ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: M q3 - 6 q3 PERMIT NO. (206) 431 -3670 WOrajrrarg M IA I I 111 ... ype o ns ton: Rod SpeZI Instrucilons: ,., , . Date Wanted Requester: ,•••• Phone No.: I A CITY OF TUKWILA BUILDING DIVISION Approved per applicable codes. COMMENTS: Inspector: ,INSPECTION RECORD (1 : Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila, WA 9818 . A' (206) 431-3670 Ifii(Carections required prior to approval. e2.44sA 2'2 te, ce, 4...nrz7 CYare:x___p 0 $30.00 REINSPECTLON EE REQUIRED. Prior to reinspection, fee must be pi at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT Nra Date: k* * * * ** *k * ** ** ** * * * * * *` *k ** *********** * *k * *• * * * *rk, *k *, ***k* *k*k *k* IT.V OF, "TUKWILA,. WA TRANSMIT k* k******* h * * * *** *' * * * * * * *** * * *** * *•k * * ** ** * * * * ** 4i* t * ** *k ** ** TRANSMIT Num',er: ,93.001501 ,'Amount; - 30.00 1'04 54,9.3 14;24 Permit Nos M93 -01b1 Type: B -MI CH MECHANICAL PERMIT. Parcel POI 00'0400 , -00.03 site Address: 12u00 INTERURBAN AV a men.t. Method.:CHECK- N •STAR SERVICES Irr.it: SLB .: .4: * *144,44 * *.k ** * *k* * *: * *. * *i ** * * ** 4, 4* * * * * *k. ** ** *A* * * **4(** * * .. Accaunt Code ' 'Description Paid 000 PLAN CHECK - NONRCS 6.00' 000/322.100 MECHANICAL. NONRES 24.00 Total (This Payment); 30.00 Total Fees: 30.00 All Payments: 3 0.00 lal ancee .00 .: • ww,w nr r�r rrwrrrrrrw.rwrrwwwr�rwww .r r ••,, • Address: 12600 INTERURBAN AV S CITY OF TUKWILA Permit No: M93 -0161 • Tenant: STAR HEATING Status: ISSUED Type:.B -MECH A p p l i e d : 10/12/1993 Parcel #: 000480 -0003 Issued: 10/15/1993 **'********************• k*** * * *****• * * *•k *** * * *•k *•k * * **** fC **** * * * *•k ** * *** k** * *** Permit Conditions: i ∎,t ^p ns .,. ru ..,.� 1 No changes w 1 1 be made.. -t�ti •h:e:.. >5�ris unless approved by the ., Architect and the Tukwlrl;a'n' :B•ui Division :':'i 2. Plumbing permit shall be obtained through the: Se ;t l e -Kin County Department of Pub toj Heal t `4`� P 1 umb ng A. 'be h ,,; 1 w 1� l;1` �. inspected b �r that agency, ` 1 incIludring 0;1 ga's >'`pi,ping': (296 -4722) `�' ' ° r tit IY 'r, ,4 , 1 Fi ;, ,, it d a f .• �t �r r. ,g w n .., + : ,y � � u 3. All mechanical work shall ° be "under `s'eparate 'Permit thro the City of` TuF;Wi•,la , t ` t v. , �, . 4. All per °in on reco'rds!,;, {and approved 'r :p l ans4: s ha 1 l�; bye maintained�available at the krj�ob site prior to the start any c,aristrr.r c,tion. These.�docu,ments to be maintained` available ` l final ., n'specti,on approval is granted:"" 5. Rea0:.i. accessible access to iioof` mounted equipment. i' reqWecq r 6. Anyr b,ackimg in mater ri'al L•��shal l have a Flame p e Rating of S re a`d Ratin "w ` ' ri�1 stal bear ' 2 5 or' les s,��and . },- f ication showing the f i. rf re peormance 1 r thereof .,:_ °; f' t,e 7. A to, be :'done'` confo'rm`ence"�,with a pro °v �i � .. p , e d plan and...,rwequirelrrents,of thke '..Bu•i } ng Code (;19931 . Ed on%4as amende:d2b,y' the Was4h`i,ngton..•5tate'' Building Code,, Uni t fo 'rm Mec an'ical 'C ( } �' d ` o:d 1. =991 Edition: ?p. r a�••'�.Washingts3'n State d 6 A . i =' r.1 1 . ,)` Ener y Codei (1991 Second Edition')'` ,.I' '._,... 8. Val of,.Permit. The issuance "ofj°aa°= permit o r approval o plan s ,,,, i ecgifications and comput t'io \sha , .no't be cpn•. i dry sp l � �•. y • ,. strue` )to�l sea permit for, . or an approval of. a ny ;:`viola tri of an kJ4 the provisions of this i co or o a other ordinan i .„ of the jurisdiction. �` N'o permit pr.e'suming to giv:e.: authoriy . `nor vi to 'or„, cancel 't ,. >w `: � � s:� 1 lie p r o v i s i o n s'` o f t c00 shall be 'V lid.., =i, `J ''‘,P �,, 4)I I ••• • C E PERMIT WIRED FOR: MECHANIC % ELECTRICA [] pLUMBIN _P agc CITY OF 'TUKWILA IP G DIVISION Date lof , -3 �S 'ermit No. „ 1� GAS /ELECTRIC P PG /PGX Series • Cooling Capacities from 23,000 to 57,000 BTUH • Heating Input rates from 40,000 to 140,000 BTUH Description ! Application • Self Contained Heating and Cooling Unit • Side by Side or Downflow Applications • Outdoor Package Unit for Ground or Rooftop Application Accessories • L.P. Gas Conversion Kits • Room Thermostat Accessories (Factory • Roof curb • Concentric converter • Economizer (Horizontal and Vertical) • Manual fresh air damper (0•25 %) • Motorized fresh air damper (0.25%) , • Rectangular to Round converter •I Io..J I 7t 2 THRU 5 TON ..,. .•v, VV id 7V IV 0� �,�\N �) • High efficiency erfo performance II V - SW CC ina X AI/ Lir I Wl tl L air condilioning & heoling 111 FILE COPY t understand that the Plan Check approvals are ubject to errors and omissions and approval of plans does not authorize the violation of any 'dopted code •r ordinance. Receipt of con - tr actor's copy: pproved plansckflowledged. AIR CONDITIONING Standard Features • Two speed evaporator blower motor • Quiet operating top condenser discharge • Copper tube • Aluminum fin coils • Totally enclosed, permanently lubricated con- denser fan motor • Hermetically sealed compressor with internal relief valve • Liquid line filter drier tagD • Power assisted combustion requiring no vent cap U :k • Bottom handling rails Supplied) \ ....Aluminized steel heat exchanger \GO/Vater shed base 0,1;A 0 • PGX models meet Cal. Nox, emission standards • intermittent ignition RECEIVED Cabinet Construction CITY of TUKWItA • Zinc coated enamel finish • Fully insulated with blankets of fiberglas4 CT 1 2 1993 • Convenient access panels Goodman Manufacturing Company, LP. 1601 Seamist, Houston, Texas 77008 65.129 (713) 031.25 PERMIT CENTER Pti/PGX • A REVD 1193 DIMS. (INCHES) PG024 PG030 PG036 PGX024 PGX030 PGX036 PG042 PG048 PG060 PGXO42 PGX048 PGX060 A " 31'/h 33 51 55114 Millailligailliiiini 2416 D 161o_ E 20N 261• „ 16'x4 17'/4 "1614 25 20 4 27 OMNI 29110 2114 27/4 MEM " MUM 6 ) 1e f ! 3 t4 iiiiktal ACCESSORY MODEL NUMBERS ALL PG /PDX MODELS LP Conversion kit _>Essex QnI Module 611,1002 0 ` 1003.300) MODEL. NUMBERS _ LPW-04 Room Thermostat a CHT18.60 V./ 1Y1+V lV "1V VV111 V■■• wU■ I1rI 2 1 4 .' 2 2 1 1111 II01 ■.•VV VV I - 11JIV CONDENSATE DRAIN DISCHARGE PRESSURE SERVICE PORT --_.L....././..- - CONNECTION (3/4' NPT1 CCMALC SUCTION r SERVICE PORT POWGR WIRE ENTRANCE �--/// CONTROL VIRE ENTRANCE 3141' 3�• M SUPPLY GAS ENTRANCE K FRESH AIR DAIMPCR OPENING BLOWER 6 CONDENSER ACCESS PANCL. 3 WED 10:41 uuril•uK I bUF'NLY PGX Models meet California NOx Requirements (1) In accordance with D.O.E. Test Procedures (2) Certified per ARI 210 and 270 (3) BTU/Watt @ 80/67 F inside - 95 F outside air 4 rriA nu. LUO ou4 4MMU PG /FC.X - DATA AND SPECIFICA( )NS r, uu BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EF- FICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PGX0240404B PG02404o•1a P0024075.18 PGXo30o40-1A no-1075-1A P00301ocmA Pcx03eo50-IA Total Cooling -BTUH 23000._ 2300 29600 296.00 29600 35000 Sens. Cooling -BTUH 17500 17500 22100 , 22100 22100 26200 Cooling CFM Nominal 860 860 1050 1050 1050 1200 SEER (2) 10.0 10.0 10.0 10.0 10.0 10.0 EER (3) - - - - - • Sound Rating (2) 8.2 8,2 8,2 8.2 8.2 8.2 Heating Input 40000 75000 40000 75000 92000 50000 Heating Capacity (1) 32000 60000 32000 60000 73600 40000 Output Capacity • - - - - - AFUE (1) 78,0 78.0 78.0 78,0 78.0 78.0 Outdoor S. S. EN. - - - - - - Calif. SEER 73.8 75.5 73.8 75.5 72.7 72,9 Temp. Rise Range 20 -50 45.76 20 -50 30 -60 45.75 20.50 Indoor Blower Type DO DD DD DD DD DD .. Size •DxW 9x6 9x6 9x6 ,9x6 9x6 10x6 Motor H.P. 1/5 1/5 1/3 1/3 1/3 1/3 Evaporator Coil . Face Area (ft?) 2.86 2.86 2.86 2.86 2.86 2.86 Fin /In, 13 13 13 i3 • 13 13 No. of Rows 2 _ 2 3 3 3 4 Outdoor Fan Fan bia, (In.) 18 18 18 18 18 22 Motor H.P. 1/6 1/6 1/6 1/6 1/6 1/4 Condenser Coll Face Area (ft 11,30 __•, 11.30 11.30 11,30 11.30 11.30 Fln /In. 19 19 19 - 19 19 19 No. of Rows 1 1 1 1 1 1 Electrical -. Ph 1 1 1 1 1 1 Volts 208/230 208/230 208/230 - 208/230 208/230 208/230 Compr. RLA 12.1 12.1 14.8 14.8 • 14.8 15.5 Compr, LRA 57,0 57,0 76.0 76.0 76.0 -- 81.0 Indoor 131w FLA 1,7 - 1.7 3,4 3.4 3.4 _ ' 3,4 Outdoor Blw FLA 1.0 1.0 1,0 1.0 1.0 1,6 Min. Circuit Amp. 17.9 17,9 22.9 - 22,9 22.9 24.4 Max, Fuse Size 25 25 35 35 35 40 Net Weight 347 357 371 381 391 375 Ship • Ing Weight 357 $67 381 391 401 385 3 WED 10:41 uuril•uK I bUF'NLY PGX Models meet California NOx Requirements (1) In accordance with D.O.E. Test Procedures (2) Certified per ARI 210 and 270 (3) BTU/Watt @ 80/67 F inside - 95 F outside air 4 rriA nu. LUO ou4 4MMU PG /FC.X - DATA AND SPECIFICA( )NS r, uu BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EF- FICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. A E. Ea. M UM. ENGINEERS, INC. 11. • .1•••■•■• 14)4 No RECEIVED CITY OF TUKWILA OCT 1 2. 1993 PERMIT CENTER A 41111•MININIM/ A•111111•11 , • • 41111111111111111 ; . .; FARnw 1e6e1P " )) V6)7 5WfirP/o JA • . ' fre 7>P ea't/e.,4 i?L'A`• ,e4W. deg A 760 ZW fe?<11 eP•P: project subject checked date •• .41/0e44' /4/27 /• / ViAS e ‘■ date / • „ , 214.53 .r/ SCISTE0 r, m'P ' S jONALO [EXPIRES ) /-- sheet no. Jr job no. 1,7,e750 :7) ) 6.57e JO 4X)JY9 r✓,. % -I B s F PLAN project subject GP ) e- 1/✓J.JJraf --✓_- e 1/.., ,t C 0~d �"•✓ OF Il10 DO • 1 18 199 NHS 1 \1Ut6.y ., AM no. checked ) job no. �� SEP -13 -93 MON 16:26 APPLIED ENG. & MNGMT. el M me' 1. project ..e..4pi0 8201 096 P.06 by date /- 1,.Y checked sheet no. 4 74- job no. Jc P A M Nem F►:'r:PTFPe tur. , 6'!,y/ 3 ,)/?,.1 ).A4 1�1 project r+ cP , dte" subject 7, z.8 Aelf by � G . date checked le Ir sheet no. job no. Clif OF 1110 APPROVE ()CI 14 1993 Bu1t.U41db omstoN c1TY OF TU E KWILA O 1093 P ERMIr. C --Prepared-for': 1esman-'_- Address • : TUKWILA.WA Job Number : STAR HTG Date : 10-11-93 imator- ---:'--Lenihan-Di.st buting __Sertial-Number--:__60115881.20________---' _ ______________ Items Description Quantity X Factor = BTUH/F Glass: Single Pane 160.0sq.ft 1.13 181 Walls: Light 8-in concrete block or frame '420.0sq. ft-- 0.07___-_29_ Roofs: Light Slab w/susp acoustical tile ceiling ' 1,05N.0sq.ft 0.02 21 --Floors: ---Concrete-slab-on 'grade-perimeter - - '-- 132-01 in ft 0.85 112 Infiltration: 1/2 air chg (floor area) 1,050.0sq.ft 0.10 105 BTUH/F 448 - -Ventilation ----Outdoor-air...'thru-apparatus--- - - 95.2CFM 1.10 ---105 BTUH/F 553 Outdoor Winter Design Temp F 26.00 Occupied Room Heating Temp F 70.00 —Unoccupied Room Heat-ing -Temp ---- F 65.00 Unoccupied Heating Load ---Qooupied-Heat ing Load - - HEATING ESTIMATE = 17,472 BTUH = 14,882 BTUH* Light Credit -deducted CITY OF TUKWILA ULU 219 3 PERMIT CENTER � � �` Prepared for : SARRIS Address Estimator : Lenihan ITEM Exposure Windows North Walls - Partitions Roof - Ceiling Floor People (total) Outdoor Air (Total) : TUKWILA.WA North ' Electrical & Appliance Load: Fluorescent Lights (TW) Machines (NW) - Coffee Urn (gal) Room Total Heat (RTH) 1. Room Sensible Heat - e- Heat -c��^" [ --'2._S�ens ibl 3. Total Sensible Heat u� 0 ~- __]ntal-CFM Et-34002i_ Tota1 CFM Outdoor Air ___Percent Outdoor-Air__- Distributing -COOLING-EST - Quantity Outdoor Conditions (DB/WB) __-BoomJConditions Coil Entering Conditions (%}lB/WB) 160.0 sq.ft � -�0.0 420.0 1,N50.0 1,050.0 0.0 sq. ft sq. ft sq. ft sq. ft sq.ft 2,100.0 3.0 1.@ 5 persons 98.8 CFM Grand Total Heat (GTH) '--'Grand Total Heat .(GTH)-=----- • Salesman Job Number Qate--- ----- Serial Number : X Factor 23.09 420.0 sq.ft 0.84 1.32 2.42 0.85 4.00 0.00 4.50 3,600 1,400 465 8. 0 1,992 @ Sea Level 99 BFH STAR WS -10-14-93 60115881.20 = BTUH 3,694 353 —660 '---- 1,016 893 4,200 0 9,450 10, 800 1,400 2, 325 34,791 BTUH 790 (RSH) = 33,766 BTUH 0.97 (SHF) _�__- �TSH� = 34,766 BTUH 84.00/ 65.00 75,00/-e‘2.55 RH 50"00 75.45/ 62.67 ^